Loading...
Report -fo o 1 tel UUf 9 c c'sr S 7 RECEIVED DEC 2 2 2014 FTIGARD "JV YATDU DING DIVISIQN FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard, OR 97223 SPEC SPACE 168-400 16655 SW 72ND AVENUE, #400 PORTLAND, OREGON 97223 FIRE PROTECTION EQUIPMENT SUBMITTAL VicoWorldwide Fire Protection Contacts www.tyco fire.com Products Series TY-B, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General NOTICE The Series TY-B Sprinklers described 4 2""•` 'a`."'fi1 Description herein must be installed and maintained - in compliance with this document, as y The TYCO Series TY-B, 5.6 K-factor, well as with the applicable standards t b Upright(TY315)and Pendent(TY325) of the National Fire Protection Associa- `✓ Sprinklers described in this data sheet tion,in addition to the standards of any '`Ir-" t .4qPil1 are standard response,standard cover- other authorities having jurisdiction. age,decorative 5 mm glass bulb type Failure to do so may impair the perfor- _ spray sprinklers designed for use in mance of these devices. ' light, ordinary, or extra hazard, corn- mercial occupancies such as banks, The owner is responsible for maintain- — +- – hotels, shopping malls, factories, ing their fire protection system and til " refineries,and chemical plants. devices in proper operating condition. The installing contractor or sprinkler The recessed version of the Series manufacturer should be contacted with TY-B Pendent Sprinkler, where appli- any questions. cable,is intended for use in areas with a finished ceiling.This recessed pendent sprinkler uses one of the following: Sprinkler , -, $ • A two-piece Style 15 Recessed Identification Escutcheon with recessed adjust �` ,r w ment up to 5/8 inch (15,9 mm)from Numbers (SINS) �� ,,,v.,,;, the flush pendent position. • A two-piece Style 20 Recessed TY315 Upright 5.6K. 1/2"NPT . ,f Escutcheon with recessed adjust- TY325 Pendent 5.6K. 1/2' NPT ment up to 1/2 inch (12,7 mm)from .° the flush pendent position. Technical The adjustment provided by theTemperature Ratings Recessed Escutcheon reduces the Data 135°F(57°C) accuracy to which the fixed pipe drops 155°F(68°C) to the sprinklers must be cut. Approvals 175°F(79°C) UL and C-UL Listed 200°F(93°C) Intermediate level versions of Series FM, LPCB,and VdS Approved 286°F(141°C) TY-B Sprinklers are described in CE Certified 360°F(182°C)t Technical Data Sheet TFP352.Sprinkler guards and shields are described in Sprinklers with Polyester Finish are t UL,C-UL,and VdS Approved only Technical Data Sheet TFP780. UL and C-UL Listed as Corrosion- Finishes Resistant Sprinklers. Sprinkler:Refer to Table A • Maximum Working Pressure Recessed Escutcheon:White Coated, 175 psi(12.1 bar) Chrome Plated,or Brass Plated 250 psi(17.2 bar)° *The maximum working pressure of 250 psi Physical Characteristics (17.2 bar)only applies to the listing by Un- Frame Bronze I IMPORTANT derwriters Laboratories.Inc.(UL). Button Brass/Copper Always refer to Technical Data SealingAssemblyStainless Discharge Coefficient Sheet TFP700 for the "INSTALLER ��2 v2 Steel w/TEFLON =56G K PM/psl (80,6 LPM/bar ) WARNING" that provides cau- Bulb Glass tions with respect to handling and Compression Screw Bronze installation of sprinkler systems and p y Deflector Bronze components.Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail - to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP152 TFP1S2 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* \ _ .as lfa`ITaA /4r/�iw-1'ltlh 5 /�/ 7/16" r `` �'— (11,1 mm) iI 1 `'■F4NOMINAL 2" �� �� �l MAKE-IN (50.8 mm) \ 4. 2 D , ``, 2" \� [1/ 1-3/8" ii.� 3 , �! rc (50,8 mm) 1 J 1111/ (34,9 mm) J N / ��� WRENCH FLATS t 1/2"NPT** DEFLECTOR* ----- 2-7/8"(73,0 mm)DIA. ---,— CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE G Operation Installation The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY315) and Pendent(TY325) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. - glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss of SPRINKLER WRENCH Design liquid from the bulb.With the sprinkler held horizontally, a small air bubble WRENCH Criteria should be present.The diameter of the RECESS The TYCO Series TY-B, 5.6 K-factor, (1,6air bubble is theap135°F (57°telyC) )1/16to inch Upright Y315 and Pendent(TY325) inch (2,4 for for t 135°F (6 360°F (1 2°C) R ) mm) the 360°F (182°C) �� Sprinklers are intended for fire protec- temperature ratings. sl *Ir tion systems designed in accordance with the standard installation rules A leak-tight 1/2 inch NPT sprinkler recognized by the applicable Listing joint should be obtained by applying a AI t or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14 is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels %r? 13, and FM Approval is based on the of torque may distort the sprinkler inlet PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the IN TO ENSURE tion Data Sheets). Only the Style 15 sprinkler. ENGAGEMENT or Style 20 Recessed Escutcheon,as Do not attempt to compensate for WITH SPRINKLER applicable, is to be used for recessed insufficient adjustment in the escutch- WRENCHING AREA pendent installations. eon plate by under-or over-tightening FIGURE 3 the sprinkler. Readjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP152 Page 3 of 4 • Step 3.Tighten the sprinkler into the 2-7/s"DIA. sprinkler fitting using only the W-Type (73.0 mm) 6 Sprinkler Wrench (Figure 2). With reference to Figure 1,apply the W-Type 2-1/4"DIA. 6 Sprinkler Wrench to the wrench flats. FACE OF — (57.2 mm) — Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15.9 mm) Recessed Pendent Sprinklers 1 \ - FLUSH The Series TY-B Recessed Pendent 3/8±5/16" ,�,� = I'' I Sprinklers must be installed in accor- (9.5±7 9 mm) 7 LI, r / I I dance with the following instructions. Step A.After installing the Style 15 or t t=� J Style 20 Mounting Plate,as applicable, MOUNTING 3,2/ over the sprinkler threads and with SURFACE _ ( mm) pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34.9 mm) threads,hand-tighten the sprinkler into TY-B PLATE the sprinkler fitting. 3/4"(19,1 mm) Step B.Tighten the sprinkler into the FIGURE 4 Step B. fitting using onln the W-Type SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) 7spriRecessed Sprinkler Wrench (Figure WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DR. _ sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After the ceiling is installed or SPRINKLER �_2-1/4"DIA. the finish coat is applied, slide on the FITTING (57.2 mm) Style 15 or Style 20 Closure over the 5/16±1/4" Series TY-B Sprinkler and push the (7,9±6,4 mm) 1/2"(12.7 mm) Closure over the Mounting Plate until in FLUSH its flange contacts the ceiling. 1 _ Care and t I cW) —' MOUNTING 1/8" J Maintenance SURFACE (3,2 mm) The TYCO Series TY-B, 5.6 K-factor, i Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-B PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) main control valve for maintenance WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. The owner is responsible for the system from the proper authorities Sprinklers that have been exposed to inspection,testing,and maintenance of and notify all personnel who may be corrosive products of combustion, but their fire protection system and devices affected by this action. have not operated,should be replaced in compliance with this document, as Absence of the outer piece of an if they cannot be completely cleaned by well as with the applicable standards escutcheon, which is used to cover wiping the sprinkler with a cloth or by of the National Fire Protection Associa- a clearance hole, can delay sprinkler brushing it with a soft bristle brush. tion (e.g., NFPA 25), in addition to the operation in a fire situation. Care must be exercised to avoid dam- standards of any other authorities hav- age to the sprinklers -before, during, ing jurisdiction. Contact the installing The owner must assure that the and after installation.Sprinklers dam- contractor or sprinkler manufacturer sprinklers are not used for hanging p regarding any questions. any objects and that the sprinklers are aged by dropping, striking, wrench only cleaned by means of gently dust- twist/slippage, or the like, must be Automatic sprinklers are recommended ing with a feather duster; otherwise, replaced. Also, replace any sprinkler to be inspected,tested,and maintained non-operation in the event of a fire or that has a cracked bulb or that has lost by a qualified Inspection Service in inadvertent operation may result, liquid from its bulb. (Ref. Installation accordance with local requirements Section.) and/or national codes. Sprinklers which are found to be leak- Thereafter, annual inspections per • ing or exhibiting visible signs of corro- p sion must be replaced. NFPA 25 are required;however,instead of inspecting from the floor level, a Automatic sprinklers must never be random sampling of close-up visual . painted, plated, coated, or otherwise inspections should be made. altered after leaving the factory. TFP152 Page 4 of 4 P/N* 77 - XXX - X - XXX I � SIN SPRINKLER TEMPERATURE FINISH RATINGS 570 5.6K UPRIGHT(1/2"NPT) TY315 1 NATURAL BRASS 135 135°F(57°C) 571 5.6K PENDENT(1/2"NPT) TY325 3 PURE WHITE(RAL9010)" 155 155°F(68°C) POLYESTER 'Use suffix''"for ISO 7-1 connection; SIGNAL WHITE(RAL9003) for example.77-570-4-175-I 4 POLYESTER 175 175°F(79°C) 9 CHROME PLATED 200 200°F(93°C) Eastern Hemisphere sales only 286 286°F(141°C) 360 360°F(182°C) 000 OPEN— *•*OPEN indicates sprinkler assembly without Glass Bulb. Button,and Sealing Assembly TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating,(specify)finish,P/N (specify,refer to Table A) Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N(specify*) Specify:Style 20 Recessed Escutcheon with(specify*)finish, P/N(specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. t co TEFLON is trademark of The DuPont Corporation. Fire Protection Products Dyna-Thread® - M-COAT® Submittal Data Sheet r> Full Line Sch-40 Replacement Dyna-Thread—M-COAT Specifications Dyna Tho sad Pal-Coal sprinkler plot Iepresents an engineering NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR adker er i for the splint.ler pipe. Irul�.wiry.It combines bikes tri safety In;mm In;mm Lbs/Ft;kg/m Lbs/Ft kg/m Unthreaded Threaded incl l ri_,r,ily Rin al S:Ii sa Iii' with��ie is and r it ,i,�i 1" 1.080 1.330 1.75 11.39 1.00 hy•d'-ilii: :Id i-i,t'lwl.. 25 27.4 2.0 2.60 — — 11/4" 1.408 1.870 2.54 9.50 1.00 J:'' Comparison to Schedule 40 32 35.8 2.8 3.78 — — 1'h" 1.639 2.290 3.22 9.14 1.00 D,'na-Tihic.,i! —M-Coati inside diameter Is lap to 3.6`70 Large' than Sch-40 40 41.6 3.4 4.79 — — givina it Supari-.i had' islics.A so,0,1Rn !iced in combination with Dyne- 2" 2.104 3.050 4.57 8.41 1.00 Flow—M-Coat pipe, down sizing (lien occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 — — approved IJ[ PLC,arid FM for fire spunkier applications.TI ie life expectancy tancy of D a Ihiead M-Ciciat and 5cli -1)are equal based on the calculated wall Us c0 4:1: thicknesses per LiL.The consistent quality of steel used in make Dyne-Thread— APPROVED LI-Coat facilitates Smooth threading and lower maintenance costs.The e>.terioi of Dvne-Thread—Li-Coat is protected by a clean,durable mill coating tot r American Made eater t d silt lite and easy paint appll.ai gin.JVlth its inciea`ed sire-cath M,nutact[led at one 01 3 U.S. FuLllifies and U available and lighter weight, Lyna-Thread—1L,1-Coat reduces installation fatigue and through fistlibutors in the USA Canada, Mexico,and is ideal for letlri-fit applications.Cms cion Resistance Ratio(CRR) is a UL Latin tvn erica. • tdndeiwriteis Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed ®Specifications & Approvals thread. assumed to be the weakest point of the pipe length.Dyna-Thread— M-Coat and Sch-dii have the same calculated wall thicknesses at this point Dyna-Thread—M-Coat pipe is manufactured to meet:ASTM A aid ale both .S;rLried the sante CFR of 1.00. 13F,Type E GI :ie A, .and is in compliance with f1FFA-1=.All sizes cf Una-Thread—M-Coat are rated at 300 psi working k> Comparison to L.W.T. Pipe pressure. Dyna-Thread—M-Coat is UL and ULC Listed for wet, Mere Nall thrcl nes,at the unread(PPR=1.uo)gives Dyna Ttilead—PA Coat dry and pre-action sprint ler systemsand FM Approved for use In wet s sT !.r . D1'nd Thread Ml _at is app of ed tot all brit Ilf E.<., tsn;d than light—well ihneadabile pipe joints.R Ina-Thread— N'1-Cc a is ak f In,-if ic�lstandard. hanger spacing;15 ft.i�.i I can he a ed as threaded couplings and welded outlets and is suitable for all Cu;tl Jiu;i e sway bracing, circ is safe in useas drops.Dyn.i-Thi cad—id-Co.,t loll-ii ,._d, and plain-end fittings..tSee luting info nation). is safer tovmelh iLii than many zinc Coated lddhtwall threafable pipe products. Dyrli T! e d—M-Coat is inose widely accepted than li;ih1wall tlnreadable where,ch-TO is specified. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: • Locations: Comments: allied Customer Service:(800)882-5543 Fax (800)659-7730 www.alliedtube-sprinkler.com l�) • 16100 S Lathrop Ave • 11350 Noncom Rd. • 2525 N 27th Ave. TUBE& CONDUIT" Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 .P,,,,,, \atkore ©2013 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1301 . , Ductile Iron Fittings - Class 300 UL/FM 1-,k.:7'. R7 c ® us • APPROVED LISTED A Fig. 35E 3-90°Elbow Size A Packing Weight • .,.,` Part Number in in Inner Master lb _+ 1/2 35E 3004 1.13 100 200 0.2 % 3/4 35E 3006 1.31 70 140 0.3 A 1 35E 3010 1.50 40 80 0.5 i,..11 1-1/4 35E 3012 1.75 25 50 0.8 ;.:.>... 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow B Size A B Packing Weight Part Number m..-.` in in in Inner Master lb 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1:36 70 140 0.4 Ilk1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1111. A 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 351'1E3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 ' 1.90 2.10 12 24 1.3 a 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 350E3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 I Fig. 35F 3-45°Elbow c Size A Part Number Packing Weight ' 1/4, in in Inner Master lb ��•' �, 1/2 35F 3004 0.88 150 300 0.2 #%\ 3/4 35F 3006 0.98 80 160 0.3 14111 1 35F 3010 1.13 40 80 0.5 ��i, IA 1 1-1/2 35F 3014 1.44 25 50 .0 i 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 - 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Sizepart Number A Packing Weight in in Inner Master lb ..1-Not. �A 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 � 11 1 35T 3010 1.50 25 50 0.7 ImoI 1-1/4 35T 3012 .. .1.7.5 . 10 20 1.1 A A 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMI'T'H-COOPER IN'1'ERNA'1'IONAL® • 'POLL FREE 1-800-766-0076 • FAX(323)890-4456 • ww.- smithcooper.com _ -r Ductile Iron Fittings - Class 300 UL/FM c � us , APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size ' A Packing Weight PaNumber in - in Inner Master- lb 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 350P3012 2.00 35 70 . 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling 111 Size A Packing 80 Weight . p in in Inner Master lb ® A 1 x 1/2 35RC3010004 1.69 160 0.3 1 x 3/4 35103010006 1.69 60 120 0.4 ; 1-1/4 x 3/4 35RC3012006 Part Number2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size A Packing Weight Part Number B in in Inner Master lb _ • 1 x 1/2 35HB3010004 1.06 180 360 0.2 I TA 1 x 3/4 35HB3010006 1.06 180 360 - 0.1 ' i 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35H 3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 x 1 35H83024012 1.25 75 150 0.3 0 0010 1.38 40. 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35H63020014 1.38 40 80 0.6 TFig. 35SP3 -Square Head Plug Size part Number A Packing Weight in in Inner Master lb 1/2 35SP3004 0.94 600 1200 0.07 Trillit I 3/4 35SP3006 1.12 350 700 0.1 A 1 35SP3010 1.25 200 400 0.1 I S. 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat � A Size Part Number A Packing Weight �ti!„� in in Inner Master lb 1 35U 3010 2.19 20 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1111 1-1/2 35U 3014 2.62 10 2040 1.7 1..11111!.Paallm 2 35U 3020 3.12 6 12 2.4 low 113 SNII'TH-COOPER IN'TERNA'TIONAL® • 'TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com Pipe Hangers Fig.200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ®TOLCO • Fig.200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) Fig.200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) USTED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig, 200 - 1/.„ (ibmr,)thru 8" !200irmi pipe Material: Steel, Pre-Galvanized to G90 specifications oop Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: €3, ( 7,,k/ ,, • (1/2" (15nm)thru 2" (5ommi) Flared edges ease installation for all pipe types and protect CFVC plastic pipe from abrasion. Captured design .......• keeps adjusting nut from separating with hanger. Hanger is easily B installed around pipe. A For hanger with non-captured nut order Fig. 200S. • (21/2" (65mm)thru 8" (2oummr) Spring tension on nut holds it securely in hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed(1/2" (i5mm1 thru 8" (2uummi) 3 Fig.200-1/2.200-/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Fig.200-1 to 200-2 Fig.200-21/2 to 200-8 Factory Mutual Engineering Approved(FM) (41" 120mm)thru 8" (200mrr)), Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, ...,-» Type 10. Maximum Temperature: 650"F(343'C) ,„ ' Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts 'S / in place of a knurl nut. { Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2 0. .. s rx Fig.200 '� ,: Fig.200C Fig.200E Pipe Size Rod Size A B Approx.Wt./100 Part No. in. Imm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/a" 166.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" 163.5) 11 15.0) 200-1 1" (251 3/8"-16 33/8" 185.7) 25/8" 166.7) 12 15.5) 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.01 13 15.9) 200-11/2 11/2" (401 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) ' 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 112.3) " • ':' 200-3 3" 175) 3/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.31 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.01 35 116.01 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.71 66 (30.2) • 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" 1171.4) 73 (33.41 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) A0 dimens ins n harts ara orr diawirrys are in inc'res.Dimensions ahowr.In pa,entl eyes eie In mlllimeteis orI ss(Ai erwoe specified. R Fire Protection Solutions B-Line 21 by E:T•N Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCo Fig.103) • B3205L - Threaded Rod (right& left hand threads) n >� Size Range: 3/8"-16 thru 3"-4 rod Specif`Length ���� Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL •�.1\ Rod is threaded on both ends with right hand threads of the length shown.Also 1 \���1 available with left and right hand threads-specify Fig. B3205L when ordering. ��\\ll Thread Size Maximum Temperature: 750''F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L', ."' 3/e"-16 21/2" (63.5) 730 (325) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 83205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4x'L',' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/e x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) . B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (4225) 7440 (33.09) 83205-11/2 x9L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) 83205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) 83205-2x'L!` ;,.': 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21/4x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'L' ' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/ax'1' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' - 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) -,, Fig. 99 - All Threaded Rod Cut To Length r it ,war,,,,,le.1!,,,. Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length � �1V),r 111 Material Steel I* a iom Maximum Temperature: 750°F(399°C) c`o Finish: Plain. Contact B-Line for alternative finishes and materials. to d s u Order By: Part number, rod diameter and finish 1-a Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1I4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/3"x 99-3/a"x length 16 730 (324) 29 (13.15) ATR 1/2"It 120 99-1/2"x lengt 13 1350 (6.00) 53 (24.04) . ATR 5/8"x 120 99-5/a"x length 11 2160 (9.60) 89 (4037) ATR 3/4"'X 120 99-3/4"x length 10 3230 (14,37) 123 (55.79) ATR 7/8"A 120 99-7/8"x length 9 4480 (19.93) 170 (7711) , ATR 1"_x 120 99-1"x length 8 5900 (26.24) 225 (102.061 All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. R ■ Pipe Hangers&Supports 236 Rev Ned 4 2R/>014 y EA b . e by AR1 VERTICAL MOUNT SAMMYS SAMMYS® for Wood Not less than Wood Floonng 2"nominal width Product Features 11 � 111111111119TILDoubco: •No pre-drilling required. Not less than •Quick to install using the Sammy 3•nominal Nut Driver with an 18V cordless thickness(2.112`) (depth or side wood drill/driver. of vertical member) -_ •Saves time from traditional leShmethods. For vertical use- install in center of lower face. •Reduces installation cost. Mornum 2'embedment Into base material far NFPA 13 compliance. Composite I Truss •Made in the U.S A. Consult •truss manufacturer for i recommended installation point. Pre-drilling may be required for GST t i 25-380.Tool available on page 10. 1 it Rod Part Screw Ultimate UL Test FM Test Box Case Approvals Size Number Model Descriptions Pullout(lbs) Load(lbs) Load(lbs) Qty Qty — 1/4" 8002957 GST 100 114 x 1' 210 (7116'OSB) 25 125 670(314"Fly) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 3/8" 8006957 GST.75 1/4 x 3/4" 564(3/4"Ply) 25 125 9- 3/8" 8007957 GST 10 1/4 x 1" 210(7/16'OSB) 300 25 125 670(3/4'Ply) – ii Q 3/8' 8008957 GST 20 1/4 x 2" 1760(Fir) 850 1475 25 125 4i• 3/8" 8068925 GST 20-SS 1/4x2" 1760(Flr) 850 25 125 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 s 3/8' 8010957 GST 30 114 x 3" 2060(Fir) 1500 1475 25 125 #14 Black Nut Driver 3/8" 8069925 GST 30-SS 114 x 3" 2060(Fir) 25 125 Part#8113910 3/8° 8011925 GST 40 1/4 x4" 2180(Fir) 25 125 3/8" 8012925 GST 60 114 x 6" 2230(Fir) 25 125 1/2" 8013925 GST2 1/4x2" 1760(Fir) 25 125 1/2" 8014925 GST2.5-380 318x2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST3 1/4x3" 2275(Fir) 25 125 – 1/2° 8016925 GST4 114x4" 2180(Fir) 25 125 1/2' 8017925 GST 6 1/4 x 6" 2230(Fir) 25 125 _ #14 SW Red Nut Driver Part#8114910 SAMMY Swivel Head° for Wood Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. •Accommodates up to 3'/a'x 12 pitch roof. •Reduces installation cost. lip, •Allows 17°deflection from vertical. •Made in the U.S.A. Rod Part Screw Ultimate UL Test FM Test Min Box Case Approvals Size Number Model Descriptions Pullout 12 (los) Load(lbs) Load(lbs) Thickness Qty Qty 41,:, 318' 8139957 SH-GST 20 114x2' 57(Fir) 1050 1475 25 125 125 3.. . S' ' 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date irfcrmatlon.visit,v.v,v ldrnin}supervcrew.eom 4 i I ` (,,,--,-.).is