Loading...
Report (9) -pp ocx--29 RECEIVED cioceo sw s44vMkSc �y E Simplex 4O10® Fire Control Panels UL, ULC, CSFM Listed; APR 3 0 2014 Addressable Fire Detection and Control FM, NYC Fire Dept Approved* (ITV OFT1GARD Basic Panel Modules and Accessories Features BUILDING DIVISION Basic system includes: • Capacity for up to 248 addressable devices,up to 127 VESDA SLI points,up to 2000 points of _ s • Annunciation and up to 20 internal and external card 1 addresses ( _ _ = �' • Color-coded operator interface with membrane keypad includes 2 x 40 Super-twist LCD display, 3 programmable control keys and 6 programmable LEDs • CPU assembly includes dedicated compact flash 4010ES Fire Alarm Control Panels are available memory for on-site system information storage and standard (left)or with LED Annunciation(right) convenient Ethernet service port access • 8 A power supply with up to 2 A of Auxiliary power and battery charger capacity for up to 110 Ah batteries Compatible with Simplex® remotely located: (UL)or up to 50 Ah batteries(ULC)(33 Ah max in • 4098-9757 QuickConnect 2 and legacy 4098-9710 control panel cabinet) QuickConnect TrueAlarm smoke sensors • 4 on-board Class A or B,3 A NACs and one • 4003EC Small Voice Panels programmable auxiliary relay output rated for • 4009 IDNet NAC Extenders(4009A) 2 A @ 32 VDC • 4081 Series, 110Ah Battery Chargers • Class A or B Two loop Isolated IDNet • 4100-7400 Series Graphic Annunciators Communications(IDNet+)supports up to • 4190 Series PC Annunciator 248 addressable and analog sensing devices on non-twisted,non-shielded wiring • 4190 Series Fiber Modems and Physical Bridges • Remote annunciator module support via RUI(Remote • 4606-9102 Remote LCD Annunciator,4100-9400 Unit Interface)communications port,supports either Series Remote InfoAlarm Command Centers,and Class B(Style 4)or X(Style 7)Pathway operation 4602 Series Status Command Units(SCU)and • 48 LED panel mount annunciation provides 40 Red Remote Command Units(RCU)Annunciators and 8 Yellow pluggable LEDs(select models,meets • IP communicator compatibility ULC requirements),optional LED kits are available 4010ES Agency listings: for custom LED configurations Optional Main System Supply and door • UL Std. 864,Fire Detection and Control(UOJZ),and mounted modules include: Smoke Control Service(UUKL),and Releasing Service(SYZV) • City Connect(with or without disconnect switches) • UL Std.2017,Process Management Equipment • Alarm Relay Module (QVAX) • Truelnsight Remote Gateway • UL Std. 1076,Proprietary Alarm Units-Burglar Optional block space modules include: (APOU) • Fire Alarm Network Interface Card for 4120/4100 • UL Std. 1730, Smoke Detector Monitor(UULH) Peer-to-Peer network communications,supports either • ULC Std. S527-99,Fire Detection and Control Class B or X(Style 7)Pathway operation (UOJZC) • • Ethernet connectivity options include Building • ULC Std. 5559-04,Supervising Station(DAYRC) Network Interface Module(BNIC),SafeLINC Internet Interface,and BACpac Ethernet Portal • Dual RS-232 Module(forprinter,PC See pages 5 and 6 for additional listing information.This product has been approved by annunciator or the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California third party interface) Health and Safety Code.See CSFM Listing 7165-0026:0369 for allowable values and/or conditions concerning material presented in this document.It is subject to • VESDA Air Aspiration High Level Interface re-examination,revision,and possible cancellation.NYC Fire Dept COA#6095. • Serial DACT Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property • 8 Zone IDC Modules Class A or B of Tyco Fire Protection Products. • 4 Point Auxiliary Relay Module • Physical Bridge Network Modules S4010-0004-8 5/2013 Introduction Panel Hardware (Continued) 4010ES Series Fire Detection and Control Panels 4010ES Block Space Option Cards mount to the left provide leading edge installation,operator,and service of the 4010ES Main System Supply.There are 3 available features for customer applications in the mid-range 4"x 5"blocks for mounting 4010ES hardware options. addressable fire alarm systems market.An on-board Other 4010ES Options: The 4010ES City Connect Ethernet port provides fast external system module or the optional Alarm Relay module mount communications to expedite installation and service directly to the Main System Supply.These options are activity.Dedicated compact flash memory archiving provides secure on-site system information storage of mutually exclusive. electronic job configuration files to meet NFPA 72 Network Media modules mount directly to the 4010ES (National Fire Alarm and Signaling Code)requirements. Network Interface Card. Modular design.A variety of functional modules are The Truelnsight Remote Gateway mounts on the back available to meet specific system requirements. Selections side of the 4010ES User Interface Panel. allow panels to be configured for either Stand-Alone or Networked fire control operation. The Battery Compartment located in the bottom of the 4010ES cabinet accepts two batteries,up to 33 Ah, Panel Hardware without interfering with expansion module space. The Master Controller and Main System Supply The illustrations below identify mounting locations are mounted in the upper section of the 4010ES cabinet. available for optional 4010ES modules. ; 4"x 5" Main System Truelnsight Remote Blockn Supply I Gatewaymounts on 3 available 4"x 5" block spaces for `� the back of the 4010ES additional option cards 4"x5" 4"05" User Interface Panel Block B Block D 41111111111.0M10111' 410111111.1.11 Mounting Locations for Optional Modules Mechanical Descri•tion Software Feature Summary • Mounting box provides convenient stud markers for • TrueAlarm individual analog sensing with front panel drywall thickness and nail-hole knockouts for quicker information and selection access mounting • "Dirty"TrueAlarm sensor maintenance alerts, service • Smooth box surfaces are provided for locally cutting and status reports including"almost dirty" conduit entrance holes exactly where required • TrueAlarm magnet test indication appears as distinct • The hinged User Interface panel easily opens for "test abnormal"message on display when in test mode internal access • TrueAlarm sensor peak value performance report • Modules are power-limited(except as noted,such as • "Install Mode"allows grouping of multiple troubles relay modules) for uninstalled modules and devices into a single • Doors include tempered glass inserts,boxes and doors trouble condition(typical with future phased are available in platinum or red expansion);with future equipment and devices • Box and door/retainer assemblies are included with grouped into a single trouble,operators can more Basic Panel assemblies clearly identify events from the commissioned and occupied areas • Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring • "Recurring Trouble Filtering"allows the panel to recognize,process,and log recurring intermittent troubles(such as external wiring ground faults),but only sends a single outbound system trouble to avoid nuisance communications • WALKTEST silent or audible system test performs an automatic self-resetting test cycle 2 S4010-0004-8 5/2013 Operator Interface Features • Convenient and extensive operator information is Convenient Status Information.With the locking provided using a logical,menu-driven display door closed,the glass window allows viewing of the • Multiple automatic and manual diagnostics for display,status LEDs,and available operator switches. Features include a two-line by 40-character,wide viewing maintenance reduction angle(super-twist)LCD with status LEDs and switches as • Convenient PC programmer label editing shown in the illustration below. • Password access control LED indicators describe the general category of activity being displayed with the LCD providing more detail.For • Alarm and Trouble History Logs(up to 2000 total the authorized user,unlocking the door provides access to events)are available for viewing from the LCD,or the control switches and allows further inquiry by capable of being printed to a connected printer,or scrolling the display for additional detail. downloaded to a service computer The following illustration identifies the primary functions of the operator interface. ` FIRE ALARM ACK acknowledges a Fire Alarm condition,logs the acknowledge,and silences the operator panel and all annunciator tone-alerts PRIORITY 2 ACK acknowledges a Priority 2 Alarm condition,logs the acknowledge,and silences the operator panel and all annunciator tone-alerts SUPV ACK acknowledges system supervisory 'ULC SYSTEMS 6 SYSTEM STATUS INDICATOR LEDs provide conditions,logs the acknowledge,and silences the require designating system status indications,LEDs flash to indicate operator panel and all annunciator tone-alerts a Ground Fault a change in status and remain on-steady after TROUBLE ACK acknowledges system trouble indicator , acknowledged until reset conditions,logs the acknowledge,and silences the operator panel and all annunciator tone-alerts ALARM SILENCE causes audible notification 2 X 40 LCD READOUT,LCD is appliances to be silenced(depending on panel 3 PROGRAMMABLE LEDs backlighted during normal conditions, programming)typically after evacuation is complete and two selectable as Red or Yellow, provides up to 40 characters for custom while alarm source is being investigated;may allow one selectable as Green or Yellow label information visible notification to continue(strobes still flashing) . .• AM SLAY pY Custom label insert be FIRST selectedALRfor maintainedDIPodisplayeration ofcan first allSalarmSTEMedRESET inputs are restores returnedcontrol to normalpanelto normal when alarm until acknowledged • ' - • waterflow-east SYSTEM IS NORMAL oEF 12:25: 15 am MON 20-MAY-13 T 5 ���y3"` • Waterflow-west ALARMS WARNINGS Au_ MNO POR AENCE AC - , (;: FIRE PRIORRV 2 SUPERVISORY TROUBLE SILENCED POWER - -- Ground Faun • • • • • • 4 5 6, s u rz ,- -- R�AUPo.I wIhTW*V2 SUPV. TROUBLE ALARM SYSTEM q * f„,� L .. • City Disconnect ACK ACK ACK ACK SILENCE RESET 7 8 • i Elevator Bypass p L. , E0i1)16 Arm Tim, e 3 5. �.; _...,,, • Ground Fault Disable on Auto.:'. `, ✓' ,'. ,ktmxs 1 h'itrft C#gi#1"... , Latch dYwarm ,;., 'w'` . : Simplex Fire Control 4010 I \ ,3 PROGRAMMABLE POINT STATUS -, ADDITIONAL FUNCTION LCD NAVIGATION-, NUMERIC KEYPAD for N FUNCTION SWITCHES CONTROL KEYS: KEYS: CONTROL: point category and point with yellow LED Point Enable and Event Time Request Menu selection selection(alphabet indicators Disable More Information Request Vertical and characters are not used at Force On or Arm Lamp Test Horizontal position this time) Force Off or Disarm •' selection buttons Return On/Off or ` • Arm/Disarm to Auto Mode 3 S4010-0004-8 5/2013 Compatible Peripheral Devices The 4010ES is compatible with an extensive list of remote Status is determined by comparing the current sensor peripheral devices including printers,PC Annunciators and value to its average value. Tracking this average value as both conventional and addressable devices including a continuously shifting reference point filters out TrueAlarm analog sensors. environmental factors that cause shifts in sensitivity. Addressable Device Control Programmable sensitivity of each sensor can be selected at the control panel for different levels of smoke Overview.The 4010ES provides standard addressable obscuration(shown directly in percent)or for specific device communications for IDNet compatible devices. heat detection levels.To evaluate whether the sensitivity Using a two wire communications circuit,individual should be revised,the peak value is stored in memory and devices such as manual fire alarm stations,TrueAlarm can be easily read and compared to the alarm threshold sensors,conventional IDC zones,and sprinkler waterflow directly in percent. switches can be interfaced to the addressable controller to communicate their identity and status. CO sensor bases combine an electrolytic CO sensing Addressability allows the location and condition of the module with a TrueAlarm analog sensor to provide a connected device to be displayed on the operator interface single multiple sensing assembly using one system LCD and on remote system annunciators.Additionally, address.The CO sensor can be enabled/disabled,used in control circuits(fans,dampers,etc.)may be individually LED/Switch modes and custom control,and can be made controlled and monitored with addressable devices. public for communication across a fire alarm Network. (refer to data sheet S4098-0041 for details) Addressable Operation.Each addressable device on the communication channel is continuously interrogated TrueAlarm heat sensors can be selected for fixed for status condition such as:normal,off-normal,alarm, temperature detection,with or without rate-of-rise supervisory,or trouble.Both Class B and Class A detection.Utility temperature sensing is also available, pathway operation are available.Sophisticated poll and typically to provide freeze warnings or alert to HVAC response communication techniques ensure supervision system problems.Readings can be selected as either integrity and allow for"T-tapping"of the circuit for Fahrenheit or Celsius. Class B operation.Devices with LEDs pulse the LED to TrueSense Early Fire Detection.Multi-sensor indicate receipt of a communications poll and can be 4098-9754 provides photoelectric and heat sensor data turned on steady from the panel. using a single 4010ES IDNet address.The panel evaluates IDNet+Channel Capacity.The Main System Supply smoke activity,heat activity,and their combination,to provides an IDNet+signaling line circuit(SLC)that provide TrueSense early detection.For more details on supports up to 248 addressable monitor and control this operation,refer to data sheet S4098-0024. devices intermixed on the same pair of wires. Diagnostics and Default Device Type IDNet+Communications wiring specifications. IDNet+circuits may be run on NEC 760 untwisted pair, Sensor Status.TrueAlarm operation allows the control twisted pair,or shielded twisted pair conductors. panel to automatically indicate when a sensor is almost dirty,dirty,and excessively dirty.The NFPA 72 IDNet+Wiring Specifications requirement for a test of the sensitivity range of the Size 18 AWG(0.82 mm2) sensors is fulfilled by the ability of TrueAlarm operation Type NEC 760 Wire(untwisted,twisted, to maintain the sensitivity level of each sensor.CO or shielded twisted pair) Sensors track their 5 year active life status providing Farthest Distance 126-248 Up to 2500 feet(762 m) indicators to assist with service planning.Indicators occur from Control Panel at: 1 year,6 months,and when end of life is reached. per Device load up to 125 Up to 4000 ft(1219 m) Up to 12,500 ft(3.8 km) Modular TrueAlarm sensors use the same base and different sensor types(smoke or heat sensor)and can be Total Wire Length Allowed Class Note:The sum of line-to-line easily interchanged to meet specific location requirements. A or Class B,including"T-taps" capacitance plus the capacitance for Class B wiring(total for both of either line-to-shield(if shield is This allows intentional sensor substitution during building isolated circuits combined) present)=0.6 pF maximum(total construction when conditions are temporarily dusty. for both isolated circuits combined) Instead of covering smoke sensors(causing them to be *Other circuits may require shielded wiring.Review your system with disabled),heat sensors may be installed without your local Simplex product supplier. reprogramming the control panel.The control panel will indicate an incorrect sensor type,but the heat sensor will TrueAlarm S stem 0•eration operate at a default sensitivity to provide heat detection for building protection at that location. Addressable device communications include operation of TrueAlarm smoke and temperature sensors.Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value,peak value,and an average value for each sensor. 4 S4010-0004-8 5/2013 Master Controller CPU Basic Panel Descri•tion • The 4010ES Master Controller includes dedicated 4010ES panels include:an Operator Interface, Master 2GB compact flash Mass Storage memory for on-site Controller with 2GB Compact Flash,Class A or B Two- system information storage and convenient Ethernet loop Isolated IDNet Communications(IDNet+) service port access supporting up to 248 addressable and analog sensing • Convenient front panel accessed Ethernet port for devices,8 A power supply with up to 2 A of auxiliary quick and easy download of site-specific power, 110 Ah(UL)/50 Ah(ULC)battery charger programming (33 Ah maximum in the control panel cabinet),4 Class A or Class B NACs rated @ 3 A each for Special • AND,firmware enhancements are made via software Application and 2 A for Regulated 24 DC operation, downloads to the on-board flash memory 1 programmable auxiliary relay rated for 2 A @ 32 VDC, • Every downloaded job is automatically stored to 1 RUI Class B or X communications port for remote Compact flash without overwriting earlier versions annunciation devices,cabinet,and door. providing a means for recovering previous Support is for up to 20 internal and external card configurations addresses.Other standard options may be provided • Downtime is reduced because the system stays depending on model(see basic panel model selection running during download below for additional details on specific models). • Modifications can be uploaded as well as IZIMEMEMII downloaded for greater service flexibility ' ' • Mass Storage allows job specific files to be store in The Main System Supply provides the power source and the control panel such as test and inspection reports, the Input/Output connections for the basic 4010ES panel. record drawings,specifications,and more... The main features are listed in the Basic Panel description • Ethernet connectivity options include Building below. Network Interface Module(BNIC)and SafeLINC Internet Interface • RUI(Remote Unit Interface)communications port supports either Class B or X Pathway operation for remote annunciation equipment Basic Panel Model Selection Note: Supervisory and Alarm current specifications are for determining battery standby requirements. Current specifications include an active RUI channel and alarm currents include 20 IDNet device LEDs activated.Actual IDNet channel device current is not included, refer to page 6 for details. For models with 48 LED Annunciation, alarm also includes 24 LEDs activated. Panel Language& Supv. Alarm Available Model* Color Voltage Listings Features Current Current Option Blocks 4010-9401(BA) Red Basic panel with 2x40 LCD Operator English UL,CSFM,FM, Interface and(1)Two-loop Isolated 120 VAC NYC Fire Dept ZDNet+Channel,Class A or B,with 316 mA 430 mA 4010-9402(BA) Platinum support for up to 248 addressable devices 4010-9403(BA) Red UL,ULC, 3 English 4"x5" 120 VAC CSFM,FM, blocks ti 4010-9404(BA) Platinum NYC Fire Dept Same features as above with 48 LED 336 mA 495 mA annunciation 4010-9405 Red French ULC,CSFM, 4010-9406 Platinum 120 VAC FM *Models with(BA)are available as assembled in the USA by adding the suffix"BA". 5 S4010-0004-8 5/2013 Addressable Device Load S•ecifications for Battery Standb Addressable Channel Device Load Supervisory Alarm Current Current With 248 Devices,Add 199 mA 248 mA Main System Supply ZDNet+Channel Output With 125 Devices,Add 100 mA 125 mA (does not include device LEDs in alarm) With 50 Devices,Add 40 mA 50 mA Block S•ace O•tion Card Selection Note: Refer to diagram on page 2 for Option Module availability.Supervisory and Alarm current specifications are for determining battery standby requirements. Single Block Option Modules,Select Three(3) Maximum if No Dual Block Module is Selected; Select One(1) Maximum if a Dual Block Module or the Module Bracket is Selected Model Features Option Block Usage Supervisory Alarm Current Current 1 Block 4010-9912 Serial DACT (must mount in block D 30 mA 40 mA under main system supply) 4010-9908 4 Point Aux Relay Module 1 Block 15 mA 60 mA Voltage Regulator Module,22.8 to 26.4 VDC 4.9 A 4010 9916 (25 VDC nominal);isolated and resettable output; 1 Block 3 A maximum maximum includes earth detection circuit and trouble relay with 2.5 A load with 4 A load for status monitoring 4010-9918 Dual RS-232 Module 1 Block 60 mA 60 mA 4010-9915 BACpac Ethernet Portal Module; requires 1 Block 123 mA 123 mA 4010-9918 RS-232 Module(no address required) 4010-9901 VESDA HLI 1 Block 60 mA 60 mA Dual Vertical Block(Flat)Modules,Select One, or Two with 4010-9928 Bracket Kit(except for Media Cards) Model Features Option Block Usage Supervisory Alarm Current Current Dual Vertical Block Card Mounting Kit,allows 4010-9928 selecting two,dual Vertical Block(flat)modules 2 Vertical Blocks NA NA from the list below Modular Network Interface Card 4010-9922 (requires two media modules,see below) 2 Vertical Blocks 30 mA 30 mA 4010-9818 Network Media Card Wired N/A 55 mA 55 mA 4010-9819 Network Media Card Fiber Optic (mounts to 4010-9922) 25 mA 25 mA 4010-9914 Building Network Interface Card 2 Vertical Blocks 236 mA 236 mA 4010-9923* SafeLINC Internet Interface 2 Vertical Blocks 115 mA 115 mA 4010-9924* Modem Physical Bridge Class B(Style 4) Requires one of the 2 193 mA 193 mA Vertical Block spaces on the 4010-9925* Modem Physical Bridge Class X(Style 7) 4010-9928 Mounting Kit 246 mA 246 mA 4010-9926** TCP/IP Physical Bridge Class B(Style 4) 3 Block"L"Shape, requires 196 mA 196 mA one of the 2 Vertical Block 4010-9927** TCP/IP Physical Bridge Class X(Style 7) spaces on the 4010-9928 236 mA 236 mA Mounting Kit, plus Block D Dual Vertical Block(Slot)Modules,Select One if no Dual Vertical (Flat)Modules from Above are Selected Model Features Option Block Usage Supervisory Alarm Current Current 4010-9920 8 Zone Initiating Device Circuit-Class B 2 Vertical Blocks 75 mA 195 mA 4010-9921 8 Zone Initiating Device Circuit-Class A (mother/daughter 9 card) *UL, ULC, and CSFM listed. **FM Approved only. 6 S4010-0004-8 5/2013 Additional Panel Option Selection (block space is not used) Model Features Supervisory Alarm Mounting Requirements Current Current 4010-9909 City Connect Module w/disconnect switches 20 mA 36 mA 4010-9910 City Connect Module 20 mA 36 mA Select one maximum, mounts on Main System Supply 4010-9911 Alarm Relay Module 15 mA 37 mA 4190-6104* Truelnsight Remote Gateway 62 mA 62 mA Mounts on Front Door 4100-5128 Battery Distribution Terminal Block,mounts to side of box, required when battery connection leaves the 4010ES box(also used in the 4100ES fire alarm control panel) *Refer to data sheet S4100-0063 and contact your local Simplex product representative for more details. Cabinet Dimension Reference Front view,cabinet outline without door Side view with door attached 16"(406 mm)--► Total depth, Box depth, box and door 6-29/32" 11-11/16" 175 32 (296 mm) O Exposed cabinet for Use 4 holes to semi-flush mounting .4-- Secure box to wall 1-3/8"(35 mm)minimum 22" (559 mm) Stud alignment Exposed door and cabinet markers, each side for semi-flush mounting 6-1/8"(156 mm)minimum 6"stud Door thickness I(4"stud Reserved for Batteries 4-3/4"(121 mm) i to 21 • F4 24"(610 mm) Miscellaneous Accessories LED Kits Model Description 4100-9843 8 Yellow LED Kit 4100-9844 8 Green LED Kit 4100-9845 8 Red LED Kit 4100-9855 8 Blue LED Kit End User Programming Tools Model Description 4100-8802 End User Programming Unit Software 4100-0292 Custom Label Editing(USB Dongle) 4100-0295 Port Vectoring Setup and Control(USB Dongle) 4100-0296 User Group/Passcode Editing(USB Dongle) 4100-0298 WalkTest Configuration Setup and Control(USB Dongle) 4010ES Factory Programming Model Description 4010-8810 4010ES Factory Programming 4010-0831 Custom Label and Panel Programming 7 S4010-0004-8 5/2013 4010ES Card Address Allocation The 4010ES has a maximum Internal and External Card Address Limit of 20 Card Addresses.Use the Table below to calculate 4010ES card address allocation. INSTRUCTIONS:Below is a list of 4010ES equipment and the quantity of card addresses they consume 1.For the applicable control panel,write in the Card Address Consumption value in the Card Address Allocation column. (Note:Only select 1 control panel) 2.For the option cards to be installed on the 4010ES,write in the Card Address Consumption value in the Card Address Allocation column. 3.Total the Card Address Allocation column(total must not exceed 20). Model Description Card Address Card Address Notes Consumption Allocation Control Panels(Select One) 4010-9401 2x40 Display,Single IDNet Channel,Single Bay Box 2 4010-9402 4010-9403 4010-9404 4010-9405& 4010-9405 2x40 Display,Single IDNet Channel,48 Pluggable LED Module 3 4010-9406 are for 4010-9406 Canada Panel Option Cards(Select As Required) 4010-9901 Flat VESDA HLI Card 1 4010-9922 Flat Network Card 1 4010-9908 4 Point Flat Aux Relay Module 1 4010-9912 Serial DACT 1 4010-9923 SafeLINC Internet Interface Card 1 4010-9914 Building Network Interface Card 1 4010-9918 Dual RS-232 Module 1 4010-9920 8 Zone Initiating Device Circuit-Class B 1 4010-9921 8 Zone Initiating Device Circuit-Class A 1 Remote Annunciation(Select As Required) 4100-9401 Red Cabinet,English 2 4100-9403 Remote Platinum Cabinet,English 2 4100-9421 InfoAlarm Red Cabinet,French 2 for Canada 4100-9423 Command Platinum Cabinet,French 2 for Canada 4100-9441 Center Red Cabinet,with blank inserts for key labels 2 4100-9443 Platinum Cabinet,with blank inserts for key labels 2 4606-9102 4010ES RUI LCD Annunciator,English 1 4606-9102BA 4010ES RUI LCD Annunciator,English 1 4606-9102CF 4010ES RUI LCD Annunciator,French 1 for Canada 4602-9101 Status Command Unit(SCU)LED Annunciator 1 4602-9102 Remote Command Unit(RCU)LED Annunciator w/control 1 4602-9150 Graphic I/O RCU/SCU Assembly for custom annunciator panels 1 4602-7101 Graphic I/O RCU/SCU Assembly for custom annunciator panels 1 4602-7001 RCU for cabinet mount 1 4602-6001 SCU for cabinet mount 1 4100-7401 24 Point I/O Graphic Module for custom annunciator panels 1 4100-7402 64/64 LED Switch Controller for custom annunciator panels 1 4100-7403 32 Point LED Driver Module for custom annunciator panels 1 4100-7404 32 Point Switch Input Module for custom annunciator panels 1 Total Card Addresses(Not to Exceed 20) TOTAL 8 S4010-0004-8 5/2013 General S•ecifications AC Input Current 4 A maximum, 120 VAC @ 60 Hz nominal Including module currents and auxiliary power Output switches to Power Supply Output Total Power Supply outputs;8 A total for"Special Application" battery backu Ratings(nominal 28 VDC Output Rating appliances;4 A total for"Regulated 24 DC"power during mainsp AC on AC,24 VDC on (see below for details) failure or brownout battery backup) _ Auxiliary Power Tap 2 A maximum, rated 19.1 to 31.1 VDC conditions Special Application Simplex 4901,4903,4904,and 4906 Series horns,strobes,and combination horn/strobes and Appliances,maximum of speaker/strobes(contact your Simplex product representative for compatible appliances) 70 appliances per NAC Regulated 24 DC Power for other UL listed appliances; use associated external synchronization modules where Appliances required UL listed for battery charging of 6.2 Ah up to 110 Ah; ULC listed for Battery capacity range charging up to 50 Ah batteries;batteries above 33 Ah require separate Battery Charger Rating cabinet (sealed lead acid batteries) Charger characteristics Temperature compensated,dual rate, recharges depleted batteries within and performance 48 hours per UL Standard 864;to 70%capacity in 12 hours per ULC Standard S527 Operating Temperature 32°to 120°F(0°to 49°C) Environmental Operating Humidity Up to 93%RH, non-condensing @ 90°F(32°C)maximum Additional Technical Installation Instructions 579-989 Reference Operating Instructions 579-969 Additional Corn•atible E•ui•ment and Reference Subject Data Sheet Subject Data Sheet 4010ES Agent Release Applications and S4010-0005 Network Communications S4100-0056 Accessories Agent Release Accessories S2080-0010 Multi-Signal Fiber Optics S4100-0049 Building Network Interface S4100-0061 4602 Series SCU/RCU S4602-0001 SafeLINC Internet Interface S4100-0062 PC Annunciator S4190-0013 Interface to VESDA Air Aspiration Detection S4100-0026 Addressable Device Compatibility, IDNet S4090-0011 Systems Communication Sensors and Devices Serial DACT(SDACT) S2080-0009 4009 IDNet NAC Extender S4009-0002 Fire Alarm Network Overview S4100-0055 4003EC Voice Control Panel S4003-0002 Truelnsight Remote Service S4100-0063 120 VAC Desktop Remote Printer S4190-0011 4606-9102 Remote LCD Annunciator S4606-0002 110 Ah Batteries and Cabinets S2081-0012 Graphic I/O Modules S4100-0005 Remote 110 Ah Battery Chargers and Cabinets S4081-0002 Remote InfoAlarm Command Center S4010-0008 BACpac Ethernet Portal Module S4100-0051 PC Annunciator S4190-0013 Network Physical Bridge S4100-0057 TCP/IP Physical Bridge S4100-0029 9 S4010-0004-8 5/2013 TYCO,SIMPLEX and the product names listed in this material are marks and'or registered marks.Unauthorized use is strictly prohibited VESDA is a trademark ofXtralis Pty Ltd.NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association(NFPA).ASHRAE and BACnet are trademarks of ASHRAE,American Society of Heating,Refrigeration,and Air Conditioning Engineers. ®S i m p I Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4010-0004-8 5/2013 www.simplexgrinnell.corn 0 2013 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. ELS implex LifeAlarm Fire Alarm Controls UL, ULC, CSFM Listed; FM Approved; 4009 IDNet NAC Extender for Control from 4010, 4010ES, MEA (NYC)Acceptance* 4100ES/41000 IDNet Communications, or Conventional NACs Features Provides additional notification appliance circuit ®J -,[- ; (NAC)capacity with flexible operation modes and •11111 Pl. power-limited design Up to 8 NACs Four, Class B NACs are standard: ` �� 6 • Rated 2 A each for conventional reverse polarity 4009 IDNet 24 VDC notification appliances and providing NAC Extender — - — multiple operation modes -=aM=MMWE-g ® r,w<l • Can be selected to provide synchronization for ' Simplex®visible notification strobe flashes i • Capable of controlling TrueAlert non-addressable Optional IDNet notification appliances operating with SmartSync III=MArima---a= Channel Repeater two wire control mode** M---------M Input control options: ;I �`. - 1, • IDNet addressable communications from a Simplex 2-Wire IDNet ,\``\ `�� • model 4010,4010ES,4100U,or 4100ES Fire Alarm Communications `.�\`� • •`• Control Panel** i • ` Fiber Optic IDNet \ • Or from one or two conventional 24 VDC NACs with 1 Communications DE \ multiple output control options .•.• NAC Control IDNet communications control benefits: , - • Provides status monitoring and individual NAC control IDNet Fiber using a single address per 4009 IDNet NAC Extender Optic Transmitter • Supports IDNet"Device Level"earth fault location WALKTEST operation is available with either 4010(shown)or I input choice 4010ES/4100ES/41000 imismommna Internal 8 A power supply/battery charger: Fire Alarm Control Panel • Charges internal batteries up to 12.7 Ah or up to 18 Ah Fire Alarm Control Panel with batteries in external cabinet Conventional NACs • Provides status monitoring of battery,input power,and 4009 IDNet NAC Extender Connection Reference Drawing earth faults Introduction • Rated 8 A for"Special Application"appliances; including Simplex 4901,4903,4904,and 4906 Series ADA Compliance.Complying with the notification horns,strobes,horn/strobes,and speaker/strobes requirements of ADA(Americans with Disabilities Act) • Rated 6 A for"Regulated 24 DC"appliance power may require more notification appliance power than is Optional 4009 IDNet NAC Extender modules: available within the fire alarm control panel.When • IDNet Communications Repeater provides Class B or additional power is required,a Simplex 4009 IDNet NAC Class A output Extender can provide up to 8 A of NAC power with up to eight,supervised reverse polarity NACs. • IDNet Communications Fiber Optic Receiver/Repeater, Location Flexibility.The 4009 IDNet NAC Extender available as Class B or Class X can be mounted close to a compatible dedicated host • Four additional Class B NACs,rated 1.5 A for Special Application appliances; 1 A for Regulated 24 DC panel or can be located remotely for convenient power distribution.Multiple operation modes and multiple appliance power connection options further increase location flexibility. • Class A,Two Circuit Adapter Module Additional Information.For additional operation detail UL Listed to Standard 864 and application information,refer to Installation External Accessories Instructions 574-181 and field wiring diagram 842-068. IDNet communication fiber optic transmitters: • ULC listed model is 4009-9202CA.This product has been approved by the California • Fora applications requiring the data integrity available State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and PP q g g tY Safety Code.See CSFM Listing 7300-0026:214 for allowable values and/or conditions with fiber optic communications concerning material presented in this document.It is subject to re-examination,revision, • Available as Class B or Class X and possible cancellation.Accepted for use—City of New York Department of Buildings MEA35-93E.Additional listings may be applicable;contact your local Simplex product • Mounts in standard six-gang electrical box supplier for the latest status.Listings and approvals under Simplex Time Recorder Co. are the property of SimplexGrinnell LP,Westminster. External battery cabinet for 18 Ah batteries •=4100U requires revision 11 software or higher for compatibility.4010 requires revision 2 software or higher for compatibility. S4009-0002-11 1/2013 Application and Operation Information IDNet Addressable Communications Compatible. Hardwire Control Applications.For applications Up to ten(10),4009 IDNet NAC Extenders can be where an existing(or new)conventional NAC needs controlled per 4010ES/4100ES/4100U IDNet additional power,the 4009 ZDNet NAC Extender can be communications channel;up to five(5)can be controlled controlled directly from the NAC.Either one or two on the 4010 IDNet communications channel.Each output NACs,from either the same,or from different host fire NAC can be individually controlled for general alarm or alarm control panels,can be connected to control the 4009 selective area notification requiring only one point IDNet NAC Extender output NACs.Multiple control address per Extender. Individual Extender NACs can also selections provide flexible operation.(Refer to page 4 for be manually controlled from the host panel.IDNet more detail.)Alarms from the host panel will activate the controlled extenders will inform the host panel of troubles four,4009 IDNet NAC Extender NACs(or optionally, via IDNet communications.4010ES/4100ES/4100U eight NACs)to extend the alarm. control panels control using multi point rules,refer to The 4009 IDNet Extender monitors itself and each of its data sheet S4090-0011 for details. output NACs for trouble conditions,including earth Optional ZDNet Repeaters.IDNet communications can faults.Extenders wired to conventional NACs will be repeated with the optional ZDNet Repeater Module or indicate a trouble by opening the path to the NAC's with the optional Fiber Optic Receiver Module.Up to 100 end-of-line resistor,but retaining the ability to respond to of the IDNet channel points can be repeated once(refer to alarms.Individual troubles are also annunciated by LEDs pages 3 and 5 for details).Repeated IDNet communications located on the 4009 IDNet NAC Extender main circuit also support the"device level"earth fault location utility of board.(Refer to page 7 for more diagnostic information.) the host panel. Product Selection Standard Models Model Description 4009-9201 4009-9202CA* 120 VAC input 4009 ZDNet NAC Extender with 4,Class B NACs and 8 A power supply 4009-9301 240 VAC input *ULC listed model Optional Modules (for on-site installation) Model Description Comments Additional four point NAC module,rated 1.5 A Special 4009-9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum power,Class B 4009-9808 Dual Class A adapter(for two NAC outputs) Select as required(4 maximum) 4009-9809 ZDNet Repeater,output is Class A or Class B Select either an IDNet Repeater or a Fiber 4009-9810 Class B Optic Receiver as required;one transmitter 4009-9811 Fiber Optic Receiver Class A(IDNet),Class X(fiber) can connect to one receiver 4009-9805 Red Appliqué for door Select if required 2975-9801 Beige trim 1-7/16"wide(78 mm),use if required for 2975-9802 Semi-Flush Trim Kit Red trim semi-flush installations Battery Selection (select battery size per system requirements) Model Description Comments 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10 Ah Battery, 12 VDC Two batteries are required,24 VDC 2081-9288 12.7 Ah Battery, 12 VDC operation 2081-9275 18 Ah Battery, 12 VDC Requires external battery cabinet,two batteries are required,24 VDC operation External Accessories (select per system requirements) Model Description Comments 4090-9105 IDNet Fiber Optic Class B operation Mounts in six-gang electrical box, refer to 4090-9107 Transmitter Class X operation page 4 for mounting details 4009-9801 External battery cabinet for up to 18 Ah batteries,beige 16-1/4"W x 13-1/2"H x 5-3/4"D (413 mm x 343 mm x 146 mm) 4081 Series End-of-Line Resistor Harnesses;see data sheet S4081-0003 for details 2 S4009-0002-11 1/2013 T •ical IDNet Connection Exam•le F Typical IDNet compatible devices (Refer to individual devices for actual wiring requirements,some wiring is not shown.) • T IDNet addressable communications channel, .4 "shown Class B(Style 4) Output NACs,four standard, Conventional NAC operation(horns) eight with expansion option Ai--Select conventional _ __�= or SmartSync mm---- 4100ES(shown) ======= operation per NAC or 4010ES/41000/4010 - - Fire Alarm Control Panel — a �7 _ SmartSync operation(horns and strobes) 4009 IDNet NAC Extender with mmEaammizgm - � ___ - Conventional NAC optional internal IDNet Repeater \ C� operation(strobes) ReoeatedIDNetChannel: "..-..3 IMMINNI TT7! up to 100 devices maximum on repeater output, T 250 devices total on IDNet Channel Ci( ` i i_T IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to ten(10)4009 ZDNet NAC Extenders may be connected per 4010ES,4100ES or 4100U IDNet channel, up to five(5)on the 4010 IDNet channel. IDNet communications can be repeated only once(can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System Connections Two fiber cables,3000 ft Output NACs 4090-9105,Class B (914 m)maximum distance :®moi lEl'eli (Style 4)Output Fiber g- � --o- , EMI ►,11MI MUM Optic Transmitter S i ' —► J 11111101111Mil—1 / F-- - it villr— I IDNet addressable communications channel Class B(Style 4)or Class A (Style 6),Class B shown Reoeated ZDNet Channel:up to 100 devices maximum on repeater output,250 devices total on IDNet Channel IMMINIIIIIM11111111111111111111111111111 Four fiber cables,3000 ft 4010,4010ES, (914 m)maximum distance 4100ES,or 41000 Fire Alarm Control Panel • 24 VDC power for rIMITI tiT �"' fiber optic transmitters --S�� _i= eori " 4090-9107,Class A(Style 7) • 11 E•41 '" W. Output Fiber Optic Transmitter s Wifig_i� NU 4009 IDNet NAC Extenders with optional Output NACs internal IDNet Fiber Receivers NOTE: Up to ten(10)4009 IDNet NAC Extenders may be connected per 4010ES, 4100ES or 41000 IDNet channel, up to five(5)on the 4010 IDNet channel. IDNet communications can be repeated only once(can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one receiver in a 4009 IDNet NAC Extender. 3 S4009-0002-11 1/2013 Hardwire Control Connection Information SmartSync Notification Appliance Control NAC Input Selections.The 4009 IDNet NAC The TrueAlert Notification Appliance product line Extender can be selected to: includes addressable and non-addressable operation. • Track input NAC operation or to provide a locally Non-addressable models are available with 2-wire SmartSync operation or conventional 4-wire operation. generated code,selectable per NAC input The following details apply to use with the 4009 IDNet • If selected for local coding,NAC outputs can be either NAC Extender Temporal Coded or 60 Beats/min March Time Coded, one code selection per extender(input NACs must be on • TrueAlert non-addressable models with SmartSync continuous with Alarm) operation allow audible notification to be separately • Additionally,NAC outputs can be selected to provide controlled over the same wire pair that controls visible the Simplex strobe synchronization signal.This signal notification will synchronize the flashes of synchronized strobes but • 4009 IDNet NAC Extenders can be selected to provide will be ignored by free-run strobes and audible devices. SmartSync operation whether controlled by IDNet (Strobes are for operation by noncoded NACs.) communications or conventional NACs NAC input to NAC output control can be selected for • IDNet control allows output NACs to be individually standard and optional NACs per the following table: selected for conventional or SmartSync operation Conventional NAC Output Operation Options • With NAC input control,all output NACs are selected Input A B C for either conventional or SmartSync operation NAC 1 NACs 1 &2,5&6 NACs 1-4 NACs 1-8 • Refer to data sheet S4009-0003 for TrueAlert NAC 2 NACs 3&4,7&8 NACs 5-8 None Addressable operation details,contact your local SmartSync NAC Output Operation Simplex product supplier for further information on Input NAC Control Function specific TrueAlert notification appliances NAC 1 Strobe Control All NAC outputs(1-8) NAC 2 Horn Control Hardwire Control NAC Connection One-Line Reference Diagram Up to eight(8)output NACs total;hardwire control can be selected to map NAC inputs to different combinations of NAC outputs depending on system requirements NAC 1 input • (see Note 1) Conventional NACs Esgmagaimili With hardwire control, i10" NAC outputs are an • Output conventional ori / IBIESIIMMMN ► NACs SmartSync operation ca=aavga==N • 4009 IDNet NAC ® — Extender ®` Fire Alarm Control Panel with Conventional NACs SmartSync operation Class A operation,either mode,requires J1 NAC 2 input 4009-9808 Dual Class A Adapter (optional,see Note 1) To additional 4009 IDNet NAC Extenders(up to four(4), 4009 IDNet NAC Extenders per NAC);see Note 2 Notes: 1.For separate audible and visible output NAC control,or SmartSync NAC output operation,two(2)input NACs are required. NAC 1 is"on-until-reset"and NAC 2 is"on-until-silenced." 2.To synchronize strobe flash outputs for up to four(4)4009 IDNet NAC Extenders,use the synchronized strobe output from a Synchronized Flash Module(4905-9914 for Class B operation,4905-9922 for Class A operation)or, if available,from a NAC selected to provide synchronized strobe flash output. NOTE:DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574-181 for additional information and application guidance 4 S4009-0002-11 1/2013 4009 IDNet NAC Extender S•ecifications 120 VAC Input(4009-9201) 3A @ 102-132 VAC,60 Hz Input 240 VAC Input(4009-9301) 1.5A @ 204-264 VAC,50/60 Hz Ratings Hardwire Control from External Conventional reverse polarity operation NACs,Input Requirements 5 mA maximum; 16 to 33 VDC Total Rating 8 A, Special Regulated Application appliances 6 A, 24 DC appliance power Standard NACs 2 A each, Special Application or Regulated 24 DC appliance power Optional NACs 1.5 A each,Special Application appliances (requires 4009-9807) 1 A each, Regulated 24 DC appliance power Special Application Simplex 4901,4903,4904,and 4906 Series non-addressable horns,strobes, Output Ratings Appliances and combination horn/strobes and speaker/strobes(contact your Simplex product representative for compatible appliances) Regulated 24 DC Power for other UL listed appliances; use associated external synchronization Appliances modules where required Strobe Operation Up to 33 strobes per NAC can be synchronized; output NACs configured for Simplex synchronized strobe operation are synchronized to each other Auxiliary Output 500 mA @ 24 VDC nominal Optional Modules Ratings Input Power 70 mA @ 24 VDC,system supplied IDNet Input,One Address Maximum distance from IDNet source is 2500 ft(762 m) IDNet Repeater Repeated IDNet output for up to 100 devices(total IDNet devices not to exceed Module 250 per channel) (4009-9809) IDNet Output Specifications Maximum distance to farthest device is 2500 ft(762 m) Total distance including"T-taps"is 10,000 ft(3048 m) Class A loop maximum distance is 2500 ft(762 m),no"T"taps Fiber Optic Receiver Modules Input Current 4009-9810,Class B,65 mA @ 24 VDC,system supplied 4009-9811,Class X, 80 mA @ 24 VDC,system supplied IDNet Output Specifications Same as those for Repeater Module(see above) Fiber Optic Transmission Distance 3000 ft(914 m)maximum General(LED status indicators are listed on page 7, dimensions and mounting details are on page 6) Operating Temperature 32°to 120°F(0°to 49°C) Operating Humidity Range 10%to 90%RH from 32°F to 104°F(0°C to 40°C) Wiring Connections* Terminal blocks for 18 AWG(stranded)to 12 AWG(solid) Fiber 0•tic Transmitter S secifications Input Voltage 18.9-32 VDC from compatible listed fire alarm supply 4090-9105,Class B,30 mA @ 24 VDC Input Current 4090-9107,Class X,35 mA @ 24 VDC Multimode,graded index,50/125pm,62.5/125 pm, 100/40 pm,or 200 pm Fiber Optic Connections and cable Type ST connectors requirements 4090-9105,Class B operation,two fiber cables required 4090-9107,Class X operation,four fiber cables required Module Size(with mounting bracket) 6-13/16"W x 3-3/4"H x 1-1/8"D(173 mm x 95 mm x 29 mm) Green LED flashing=transmit On-board Status Indicators Red LED flashing=receive Separate red LED on 4090-9107=Class X receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 ft(914 m)maximum Wiring Connections* Terminal blocks for 18 AWG(stranded)to 12 AWG(solid) Operating Humidity 10%to 90%RH from 32°to 104° F(0°to 40°C) Operating Temperature 32°F to 120°F(0°to 49°C) *Metric wire equivalents: 18 AWG=0.82 mm2; 12 AWG=3.31 mm2 5 S4009-0002-11 1/2013 4009 IDNet NAC Extender Mounting and Module Placement Information E* 16-1/4"(413 mm) ►1 Cabinet depth 4-1/4"(108 mm) I610-29/32"(277 mm) e I Door,5/8" • J—O 0 0 0 — [ 0 v (16 mm)thick O 1- I 1 H ®® I I 10 8 if'7.1' 1. Naaid fiaa6ii Optional Class A (4009-9807 Additional Four\ 13-1/2" adapter modules point module(shown with '^' (343 mm) ® ` Class A adapters) L ® Exposed cabinet 1 1 dimension for-4J -4— 'N I i ( System Module O 0[1:110r semi-flush mount ri \ i , 1" 25.4 mm , ( ) Knockouts for screw ZDNet repeater Q(0 1-3/8"(35 mm)with or nail mounting holes Fiber optic receive semi-flush trim 0 o o -O 0 - 0 0 I Co I —— I I I. 12"(305 ►I 0 Ij Battery location,no conduit entry or wiring in I I this area(12.7 Ah battery outline shown) ' I I 1 O OI yti Semi-flush trim option Non-power limited wiring area(AC input) 1-3/16 wide(30 mm), -----1. 3/8"(9.5 mm)thick Wall surface reference for semi-flush mount NOTE: Recommended conduit entrance varies with module selection. Refer to general installation instructions 574-181, specific module installation instructions, and to field wiring diagrams 842-068 before locating conduit entrance. 4009 IDNet NAC Extender Cabinet with Door Detail Optional red appliqué (4009-9805) 0 4009 IDNet' NAC EXTENDER simplex 6 S4009-0002-11 1/2013 4090-9105/9107 IDNet Fiber Optic Transmitter Mounting Information Surface mount box: --__6_ Simplex model 2975-9217 (ordered separately) • • • • • . Flush mount masonry box: ' -, ` ` I use 6-gang box, RACO#960,2-1/2"deep o o 0 0 o a I " (64 mm),or RACO#965,3-1/2"(89 mm) rj • • I. • . I deep,or equal(supplied by others) .4,_ � , , ptm1 , 0 - Flush mount ganged boxes: Ell IP 1111 use 6-gang box, 1-1/2"(38 mm)� minimum depth;six,RACO#400 1[ ; 5 or equal, (supplied by others) 7. FMS Ulm '�i 'moi Ie .r , MI IVI Ivl o o 0 0 0 0 IDNet fiber optic transmitter: 4090-9107, Shown,Class A(Style 7)output 4090-9105, Not shown,Class B(Style 4)output INSTALLATION NOTE: Fiber optic cable bend radius should be 2"(51 mm) minimum, or per Manufacturer's specification. o 0 0 0 0 0� I Six-gang blank cover plate Mulberry Metal Products 97156 or equal(by others) Service Dia•nostic Features LED Status Indicators are provided for the following: Power-up Self-Diagnostics. Upon power up,the • Each NAC(standard and optional)has a dedicated 4009 IDNet NAC Extender tests each module and yellow LED that: performs earth fault diagnostics.Trouble conditions are — During supervision provides a slow flash to indicate communicated to the host control panel and are also a short circuit condition and a fast flash to indicate displayed on diagnostic status LEDs in the 4009 IDNet an open circuit NAC Extender.When connected via IDNet — During an alarm,the LED follows the NAC output communications,detailed status information is available (on steady or flashing with coded output) at the host.When controlled with conventional NAC inputs,common troubles are signaled by providing a • Four, general status yellow LEDs provide nine separate indications listed in priority of urgency.As a III polarized open circuit that disconnects the NAC wiring from its end-of-line resistor but still allows a reversed trouble is eliminated,any remaining trouble(s)will polarity alarm to be received. then be indicated until the 4009 IDNet NAC Extender is returned to normal operation. Door Mounted Reference Label.The 4009 IDNet NAC Extender has a detailed programming and • AC power status is indicated by a green LED that is - diagnostic label inside the front door that provides a quick on when AC is normal. During low AC(brownout) reference for both installation and checkout. conditions or with no AC,the LED is off.Additional power and battery status is indicated by the general status LEDs. 7 S4009-0002-11 1/2013 4009 IDNet NAC Extender Current Calculation Chart Step 1. Calculate Basic Extender Battery Requirements(minus NAC loads) Panel, NAC Options,and Auxiliary Power(underlined model numbers are optional modules) Model Description Supervisory Actual Alarm Current Actual Alarm Current Supervisory 4009-9201 120 VAC input Basic Panel 85 mA 85 mA 185 mA 185 mA 4009-9301 240 VAC input 4009-9807 Additional Four Point NAC 40 mA + 40 mA + 4009-9808 Dual Class A Adapter(no additional current) — — — — Auxiliary Power Output (500 mA + (500 mA maximum) maximum) +[Al] Basic Panel Supervisory Current =[S1] Basic Panel Alarm Current =[A2] Step 2. Calculate IDNet Output Module and Device Current(if used) 4009-9809 ZDNet Repeater 70 mA 70 mA Select one per 4009-9810* Fiber Optic Receiver,Class B Extender 65 mA + 65 mA + 4009-9811* Fiber Optic Receiver,Class X 80 mA 80 mA IDNet Devices(connected to Repeater or Receiver above), Total devices + Total devices + 0.7 mA each, maximum of 100 x 0.7 mA each x 0.7 mA each *Note: IDNet Fiber Optic Transmitter IDNet Module Supervisory Current [S2] = current is supplied from the host fire alarm control panel ZDNet Module Alarm Current =[A3] Maximum Available Current =8 A* Step 2.Calculate Available NAC Current Subtract Auxiliary Power Output -[Al] Subtract IDNet Module Current -[A3] *8 A for Special Application Appliances;6 A for Regulated 24 DC Appliances Available NAC Current =[A4] Step 3. Calculate Actual NAC Loading(Limited to Available NAC Current per Step 2.) NAC Type NAC Circuit# NAC Alarm Current Circuit 1 + Circuit 2 + Standard Panel NACS,2 A maximum per NAC Circuit 3 + Circuit 4 + Circuit 5 + Optional Four Point NAC Module, 1_5 A maximum Special Application rating, Circuit 6 + 1 A maximum Regulated 24 DC rating,per NAC Circuit 7 + Circuit 8 + Total Actual NAC Load Alarm Current =[A5] Step 4. Calculate Total Supervisory Current Total Supervisory Current=Basic Panel Current[S1]+IDNet Module Current[S2]=I Step 5. Calculate Total Alarm Current Total Alarm Current=Basic Panel Current[A2]+IDNet Module Current[A3]+Actual NAC Current[A5]=I TYCO,SIMPLEX;and the product names listed in this material are marks and or registered marks.Unauthorized use is strictly prohibited. ELSi m p1 Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4009-0002-11 1/2013 www.simplexgrinnell.corn c 2013 Two Fire Protection Products.All rights reserved.Allspecifications and other information shown were current as of document revision dale and are subject to change without notice. 5®SimplEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed* VLC-600 TrueAlarm LaserCOMPACT Smoke Sensor with 4100ES/4010ES/41000 IDNet and MAPNET II Communications Features .T.—.— Model VLC-600 addressable, analog output air aspiration smoke sensor provides: Typical air inlet • VESDA LaserCOMPACT operation communicating • with the established TrueAlarm analog sensing process for area coverage up to 8000 ft2 • • Compact 8'/•"(225 mm)square size I 1 Clean room cable tray • Dual stage dust filter that is used on larger systems f_..--i • Obscuration measurements communicated to the fire VLC-600 TrueAlarm Remote LED indicator alarm control panel for status determination • LaserCOMPACT Air Aspiration Smoke Sensor • Panel selected sensitivity from 0.016%/ft to 4.08%/ft _ • " • Local computer port access for the VESDA Vconfig ! "� 0 Pro software program as used on larger systems Addressable manual stations, • Single LED that indicates local status information TrueAlert sensors and other devices 4100ES/4010ES/41000 IDNet g or 4100ES/41000 MAPNET II • Capability of driving a remote LED(orderedaddressable communications separately) ( ! — {� y) — t�24 VDC power Trouble conditions are also communicated: • Mechanical problems are received as sensor troubles • Electrical problems are received as"no answer"troubles i _ • Additional details are indicated by the sensor LED and _ 111 I by accessing sensor diagnostics CLEAN ROOM • Compatible with Simplex®4100ES,4010ES, SMOKE DETECTOR ALARM 4100U,or legacy 4100/4120 fire alarm control panels: • Communications via 4100ES/4010ES/4100U IDNet i or 4100ES/4100U MAPNET II addressable formats Fire Alarm Control Panel requires 4100ES/4010ES/41000 • Connection is to the same SLC(signaling line circuit) IDNet or 4100ES/4100U MAPNET II communications with other devices such as addressable manual (4100ES shown for reference) stations,TrueAlarm area smoke sensors,addressable control modules,etc. TrueAlarm LaserCOMPACT System Connections • Communications are as a single device and connection is direct to the SLC without requiring a dedicated interface Descri•tion • 4100/4120 requires revision 8.01 or higher software Air aspiration technology smoke detection operates Three threshold levels are programmable from the by actively drawing in air for sampling in a high intensity, fire alarm control panel with typical selections as: stable detection chamber.The Model VLC-600 TrueAlarm LaserCOMPACT smoke detector uses the • Stage 1 —Alert at 0.016 to 0.6218%obscuration/ft latest in VESDA sampling technology including a highly • Stage 2—Pre-Alarm at 0.03 to 0.6234%obscuration/ft efficient laser light source and a dual stage dust filter. • Stage 3—Alarm at 0.05 to 4.08%obscuration/ft TrueAlarm analog sensing occurs when the • NOTE: UL listed evacuation alarm sensitivity is not TrueAlarm LaserCOMPACT sensor communicates to be less sensitive than 0.625%/ft smoke chamber information to the connected fire alarm Sampling pipe network: control panel.The panel evaluates the smoke sensor • Uses standard Vision Systems pipe and inlet in information against three programmed thresholds and accordance with Vision Systems Aspire design tool declares an alarm or pre-alarm condition depending on smoke chamber activity. UL listed to Standard 268(URXG) Status communications.In addition to smoke This product has been approved by the California State Fire Marshal(CSFM)pursuant to chamber information,the TrueAlarm LaserCOMPACT Section 13144.1 of the California Health and Safety Code.See CSFM Listing also advises the fire alarm control panel of local trouble 7259-1728:0109 for allowable values and/or conditions concerning material presented in conditions.Troubles may include dirty filter,airflow this document.This product was not approved by FM as of document revision date. Additional listings may be applicable;contact your local Simplex product supplier for the restriction or failure,etc. Specific details are stored in latest status.Listings and approvals under Simplex Time Recorder Co.are the property of memory at the sensor location. Tyco Fire Protection Products. S4098-0036-7 7/2013 O•eration Operation (Continued) Filtered air flow.A high efficiency aspirator Status logging. The sensor status history for all alarms, continually draws air through a simple pipe network to a service,and fault events, is monitored and logged with central detector.Air entering the sensor housing passes a time and date stamps within the electronics of the sensor, flow sensor before the sample is passed through a accessible via the local computer port.General trouble dual-stage dust filter.The majority of air is exhausted status indications are communicated to the panel as either from the detector and where required,back vented to the sensor troubles or"no answer"troubles. protected area.The first stage of the air filter removes dust and dirt from the air sample before it enters the Additional Information smoke detection chamber.A second,ultra-fine filter stage Refer to Installation Instructions 19772 shipped with the provides a clean air supply to be used inside the detection VLC-600 for additional information. chamber to form clean air barriers which protect the optical surfaces from contamination. Laser detection chamber.The detection chamber uses a stable,highly efficient laser light source and unique sensor configuration to achieve optimum response to a wide range of smoke types.When smoke passes through the detection chamber,it creates light scattering which is detected by very sensitive sensor circuitry.The analog level of the sensor is then communicated to the fire alarm control panel for comparison to pre-selected alarm thresholds. Product Selection Model Description VLC-600 TrueAlarm LaserCOMPACT Smoke Sensor(sampling pipe is ordered separately) 2098-9808 Remote Red LED Status Indicator on single gang stainless steel plate; mounting requires a single gang box, 1 'A"minimum depth;connections are color coded wire leads S•ecifications Sensor Voltage 18 to 30 VDC, supplied from fire alarm control panel Sensor Current 205 mA @ 24 VDC;supervisory and alarm Compatibility 4100ES/4010ES/41000 IDNet or MAPNET II addressable Communications communications, automatically selected Loading One address, one unit load per sensor Electrical Terminations Terminal blocks for 18 to 12 AWG Sensor Ambient 14° F to 103° F(-10°C to 39°C) Operating Conditions Sampled Air -4° F to 140° F(-20°C to 60°C) Sensor Humidity 10-95% RH, non-condensing Maximum area of coverage=8000 ft2, maximum pipe length in Sampling Network accordance with Vision Systems computer design tool(ASPIRE)and NFPA standards UL Listed Velocity Range 0 to 4000 ft/min(0 to 1200 m/min) 0.016%to 4.08%/ft obscuration, selected at the fire alarm control panel; Alarm Sensitivity Range NOTE: UL listed evacuation alarm sensitivity is not to be less sensitive than 0.625%/ft Recognized Sensitivity Levels Three levels, selectable and designated as required at the fire alarm control panel Sensor Service Access Internal DB-9, RS-232 connection for a service computer using VESDA Vconfig Pro software program (authorized service access only) Enclosure Rating NEMA 1 (IP 30) Weight 4.2 lbs(1.9 kg) 2 S4098-0036-7 7/2013 LED Status Indications Indication Meaning OFF Power off or active sensor is waiting for panel communications ON for approximately 3 seconds Power up self-test due to sensor being in reset cycle ON Steady Alarm condition as commanded from panel 1 pulse approximately every 4 seconds Normal operation, pulse indicates communications with panel 3 pulses(2 Hz rate every 2 seconds) Internal fault, not communicating with panel, sensor needs internal service diagnostics or replacement Mountin• Information Air intake location Top knockout location ) Rear knockout location Side knockouts(2) i i 7 TrueAlarm Laser; COMPACT Mounting I LED indicator) bracket \ osimplex I 8 7/8'• (225 mm) 8-7/8"(225 mm) .I -. 3-3/8"(85 mm)--H v Air exhaust location (rear assembly can be rotated 180°to reverse intake and exhaust locations, and knockout locations) 3 S4098-0036-7 7/2013 TYCO,SIMPLEX,and the product names listed in this material are marks and or registered marks.Unauthorized use is strictly prohibited. ®S imp 1 Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4098-0036-7 7/2013 www.simplexgrinnell.com c 2013 Tyco Fire Protection Products.All rights reserved.All,specifications and other information shown were current as t fdocument revision date and are subject to change without notice. B®Simplex Releasing Control Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; Releasing Control Systems Reference for the MEA (NYC) Acceptance* 4010 Fire Alarm Control Panel Features Actuator Control Circuit Releasing control using the Simplex®4010 Fire Actuator Agent Alarm Control Panel to provide**: Agent_._><_____4„. discharge source • Coverage for up to 10 hazard areas of Automatic path Extinguishing Release and/or Deluge and Preaction Sprinkler System Release moil supervisory module • Releasing Appliance Circuit(RAC)control of Jt compatible Listed/Approved 24 VDC automatic control actuators,one per circuit;or two 12 VDC actuators in per circuit o�Release series appliance circuit • RAC provides short circuit supervision to coil supervision module Maintenance f ' • Disconnect Switch 6-0 • Four,2 A Notification Appliance Circuits(NACs)in the (with indicator lamp) — / Power panel for use with Suppression Release Peripherals(SRP) d indicator lamp • Additional actuator circuit control and additional NACs 711.W.OKIN (if required) are available using 4009 IDNet Addressable NAC Suppression Extenders and Suppression Release Peripherals Release Peripheral Audible Escalation of Events: • Temporal or 20 bpm March Timepattern for first P P Addressable devicesIDNet . cross zone alarm _ I . communications • 120 bpm March Time pattern to indicate releasing timer ®4/11 active Dedicated • On steady to indicate releasing timer expired and NAC circuit actuator is activated • NOTE:Requires NACs dedicated to conventional horn control(not SmartSync operation)with strobes controlled on separate NACs 4009 IDNet NAC Extenders provide: • Up to eight NACs for notification requirements and for NAC input to Suppression Release Peripherals • Control is via IDNet addressable communications 4010 Control Panel with 4090-9005/-9006 Suppression Release Peripheral Suppression Release Appliqué with Dual Command Control: 4010 Series Releasing Control Typical Block Diagram • Dual command control requires that both IDNet communications commands and an activated NAC are Introduction present to initiate the desired release • NAC provides wiring supervision to the actuator The 4010 series fire alarm control panel is capable of including monitoring of coil continuity controlling actuators for use in automatic extinguishing, Suppression Release Peripheral control features: and deluge or preaction releasing systems.IDNet addressable communications are used to monitor initiating • An on-board DC-DC regulator compensates for devices,and for control of 4009 IDNet NAC extenders voltage drops to the peripheral and ensures proper and Suppression Release Peripherals.Releasing system control circuit voltage over a wide operating range logic is implemented within the 4010 control panel as • Provides a single RAC for control of actuators for up required for the local application. to 1 A using a 2 A NAC input * 4010 Releasing Control has been approved by the California State Fire Marshal(CSFM) Related system components: pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM • 4010 Series control panel with Releasing Appliqué Listings 7170-0026:226 and 7300-0026:313 for allowable values and/or conditions concerning material presented in this document.Accepted for use-City of New York • Dedicated NAC output from 4010 or NAC Extender Department of Buildings-MEA35-93E.Additional listings may be applicable;contact • Coil supervision module,one per RAC your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. • Maintenance Switch,one per RAC **This document describes features available with 4010 software revision 3.01 or higher. • Abort Switch connected via an addressable interface Refer to data sheet S4010-0001 for model 4010 control panel details including IDNet module communications information. UL listed to Standard 864 S4010-0003-5 6/2013 Automatic Extinguishing Release Systems Releasing System Requirements (Continued) These systems automatically activate electrically 5. FM Approved Automatic Extinguishing Release controlled actuators for the release of a fire extinguishing requires secondary standby to be a minimum of agent(such as dry chemical,water spray,foam,CO2,or 24 hours with 5 minutes of alarm.Actuators must be clean agent)in response to fire detection device inputs as electrically compatible. determined by programming of the host fire alarm control 6. FM Approved Deluge and Preaction Sprinkler panel. operation requires that: initiating device circuits be Automatic Extinguishing Release System Panels Class A and wired to Listed/Approved devices; are required to have a minimum of 24 hours of standby standby power capacity must be a minimum of 90 power.Initiating devices must be Listed/Approved for the hours with 10 minutes of alarm; and that approved application,and may be wired either Class A or B. Automatic Water Control Valves must be used.(Refer Control actuators must be electrically compatible with the to actuator list on page 7.) control panel circuits and power supplies,and are wired 7. Maintenance Switches,one per RAC,are required Class B to provide coil supervision. per NFPA 72,the National Fire Alarm and Signaling Code to allow the system to be tested or serviced Deluge or Preaction Sprinkler Systems without actuating the fire suppression systems. Their These systems automatically activate water control use may not be allowed in some jurisdictions, always actuators in response to fire detection device inputs. confirm local requirements. When used,Simplex Maintenance Switches are required to ensure that Deluge Sprinkler Systems employ open sprinkler operation initiates a supervisory condition. heads and provide water flow when the fire detection 8. Abort Switches are available when abort operation is system activates a common automatic water control required.When used,connect to an addressable actuator.They are used to deliver water simultaneously Supervised IAM model 4090-9001 or similar through all of the system sprinkler heads.This type of addressable adapter module.The Simplex abort switch system is applicable where the immediate application of and the IAM mount in a single gang box,2-1/2" large quantities of water over large areas is the proper fire minimum depth. response. 9. Addressable Manual Releasing Stations are used to Preaction Sprinkler Systems are similar to deluge initiate activation of the releasing actuators with the systems except that normally closed sprinkler heads are appropriate time delay implemented by the fire alarm used and supervisory air pressure is maintained in the control panel. pipe.Operation requires both an activated sprinkler head 10.Notification Requirements.Each hazard area and an activated fire alarm initiating device with specific typically requires general audible and visible fire programming determined at the host fire alarm control alarm notification and additional dedicated NACs for panel. area releasing status notification.Use of the 4009 Releasing System Requirements IDNet NAC Extender will provide the required additional NACs. 1. Releasing actuators are controlled from a 11.Additional 4010 Reference.Refer to Installation and Suppression Release Peripheral(4090-9005 or Operating Instructions 574-052 and Field Wiring 4090-9006).Connections are 2-wire,Class B releasing Diagram 842-058 for additional 4010 releasing and circuits with only one 24 VDC actuator per circuit. general panel information. Where applicable,two, 12 VDC actuators in series,or 12.Additional Suppression Release Peripheral one 12 VDC actuator with manufacturer supplied Reference.Refer to Installation Instructions 579-385. resistor may be used. 2. Coil Supervision Module 2081-9046 must be wired Additional Releasing Systems Reference electrically before the actuator and located in the actuator wiring junction box.(Refer to diagram on For additional information,refer to Factory Mutual page 5.)The connected RAC provides continuity Research Corporation(FMRC)"FMRC Approval Guide," supervision of the actuator coil and wiring and FM Approval standard"Deluge Systems and Preaction provides short circuit supervision to the coil Systems." supervision module. Please note that proper operation of releasing control 3. Cross-zoning or other alarm initiation logic per systems requires that the system design, installation, and system requirements,is to be implemented by maintenance be performed correctly and in accordance programming at the fire alarm control panel. with all applicable local and national codes, and 4. UL Listed Automatic Extinguishing Releasing equipment manufacturer's instructions. No liability for operation requires that:battery standby must be a total system operation is assumed or implied. minimum of 24 hours with 5 minutes of alarm and that listed actuators are used,refer to list on page 6. 2 84010-0003-5 6/2013 Product Selection 4010 Releasing Control System Modules Model Description Reference 2081-9046 Coil Supervision Module Required, one per RAC, mounts in the releasing actuator wiring junction box; see specifications section for details 2080-Series* Maintenance Switches One per RAC; flush or surface mount; indicator lamps require separate 24 VDC wiring 2080-9056* Flush mount As required, connects via an IDNet addressable interface module; Abort Switch mounted on a single gang stainless steel plate; installation 2080-9057* Surface mount requires a single gang box, 2-1/2"(64 mm)minimum depth *Refer to data sheet S2080-0010 for Abort and Maintenance switch details. 4010 Releasing Appliqués, Required for 4010 Suppression Releasing Applications Model Description 4010-9830 English Suppression Releasing Appliqué; field applied 4010-9830CAF French Suppression Release Peripheral and Accessories Model Description Reference 4090-9005 Basic Suppression Release Peripheral on Requires mounting box 2975-9227, ordered separately mounting plate 4090-9006 Suppression Release Peripheral mounted in Includes LED indicator on front of door red box; required for ULC listing 2975-9227 Red mounting box; required for 4090-9005 Red LED IDNet communications indicator These items are included with model 4090-9006 4090-9812 option kit; mounts on door of 2975-9227 box Additional Product Data Sheet Reference Subject Data Sheet Subject Data Sheet Releasing System Abort and Maintenance S2080-0010 4605 Series,24 Point I/O Annunciator Modules S4010-0002 Switches Addressable Manual Stations for Releasing S4099-0002 TrueAlarm Sensors and Bases S4098-0019 Applications Addressable Manual Stations for Standard S4099-0001 TrueAlert Electronic Horns S4901-0010 Applications 4010 Control Panels S4010-0001 TrueAlert Non-Addressable Strobes(V/O) S4906-0001 Supervised IAM S4090-0001 TrueAlert Non-Addressable 4-Wire Horn/Strobes(AN) S4903-0011 Addressable Zone Adapter Modules S4090-0003 4010 Compatible Remote Battery Cabinet with S4081-0001 Charger 4009 IDNet NAC Extender S4009-0002 Contact your local Simplex product supplier for additional information on compatible IDNet addressable devices and TrueAlert notification appliances. 3 S4010-0003-5 6/2013 4010 System Reference with 4009 IDNet NAC Extenders 4090-9005/-9006 Suppression Actuator Control Circuit Release Peripheral(SRP) Agent source Horn and strobe NACs; 01,4.4 Coil supervisory ,.,:li,!!„,':::',:°i, 4 NACs standard,up to m m module 8 NACs available R1;...,f%A ; 0= ti11\ X Actuator lir Agent discharge path IDNet communications Dedicated to up to 5 total 4009 C-1 NAC IDNet NAC Extenders ---, • – ' ae. I r is 4009 IDNet NAC Extender r' ' <<,.- 4--- 24 VDC for Maintenance Disconnect (if required) =:a==== � status indicator(if required) r — I I IDNet communications IDNet communications--..._____Q I I Dedicated NAC wiring To SRP,either from 4010 1-r,' FP-- (dashed line)or from 4009 IDNet NAC Extender � Suppression Release Appliqué wording: I , Supervised IAM with SUPPRESSION RELEASE PANEL li Jar optional Abort Switch CAUTION:This Control Unit has been arranged for releasing I service. Disable all releasing device circuits prior to servicing. IDNet Addressable devices JIIMMIMMINIMfIUIUUIINIIINlIfffflfhI — CM • 'vNAC for horn control „-,,,, 0 t i ► Use separate NACs Z ® for horn and strobe control to implement VINE M! audible escalation of events NAC for strobe control IIIIIUIOUIUIIIIIIlIUIIIIIIIIIIIINIIINIIIIIIIIIIIAII 4010 Control Panel with Suppression Release Appliqué 4 S4010-0003-5 6/2013 Suppression Release Peripheral Wiring Reference Maximum Release Appliance Circuit(RAC)Wiring Distances from Suppression Release Peripheral to the Valve Solenoid(based on a total drop of 0.6 V) RAC Output Current Distance Total Line (refer to solenoid rating) 18 AWG 16 AWG 14 AWG 12 AWG Resistance 0.50A 74ft 23m 118ft 36m 188ft 57m 300ft 91 m 1.06 f2 0.75 A 50 ft 15 m 79 ft 24 m 126 ft 38 m 200 ft 61 m 0.71 S2 1.00A 37ft 11m 59ft 18m 94ft 29m 150ft 46m 0.53c . Metric wire equivalents:18 AWG=0.82 mm2;16 AWG=1.31 mm2,14 AWG=2.08 mm2;12 AWG=3.31 mm2 Listed/approved actuator or CD CD O Deluge and Preaction NORMAL Automatic Water Control Valve; one if 24 VDC (or 2 in O� DlcSABLEr , series if 12 VDC) per RAC 'DI N'Sk 10 II IIII FIRE SUPPRESSION Yel + Blk DISCONNECT I DISABLE Out Valve wiring m OSimplex m + In - junction box Red Blk Maintenance Disconnect Switch 4090-9005/-9006 Suppression Release Peripheral Coil Supervision Module 2081-9046 Wire indicator---,� it 7 lamp with 14 AWG . m maximum 0� v 24 VDC power Releasing for indicator lamp(2 wires) Appliance Circuit Addressable devices Class B NAC wiring I --.7-- dedicated dedicated to Suppression •• r-- A Supervised IAM with Release Peripheral M, Pr A! 0 optional Abort Switch I IDNet communications, Class A or Class B To 4009 IDNet NAC Extender or 4010 Fire Alarm Control Panel • FIRE SUPPRESSION Maximum Notification Appliance Circuit(NAC)Wiring Distances to a Suppression Release Peripheral SYSTEM ABORT (based on a total drop of 3.4V) RAC Output Current Distance (refer to solenoid Total Line rating) 18 AWG 16 AWG 14 AWG 12 AWG Resistance 0.50 A 250 ft 76 m 399 ft 122 m 635 ft 194 m 1010 ft 308 m 3.58 0 PUSH AND HOLD 0.75 A 167 ft 51 m 266 ft 81 m 423 ft 129 m 673 ft 205 m 2.39 O 1.00 A 125 ft 38 m 199 ft 61 m 317 ft 97 m 500 ft 154 m 1.79 0 n C ex Metric wire equivalents: 18 AWG=0.82 mm2;16 AWG=1.31 mm2; 14 AWG=2.08 mm2;12 AWG=3.31 mm2 ✓ • ` ' 2080-9056/-9057 Abort Switch (as required) 5 S4010-0003-5 6/2013 S•ecifications Suppression Release Peripheral 4090-9005 and 4090-9006 Communications ZDNet, one address RAC Output Rating,with 4010 control panel* 1 A maximum @ nominal 24 VDC, regulated Voltage 16 to 32 VDC(nominal 24 VDC) NAC Power Requirements Supervisory Current No additional current required,circuit appears as standard end-of-line(EOL) NOTE:4010 NACs are NAC loading rated 2 A;4009 ZDNet RAC Current NAC Current NAC Extender standard Alarm Current NACs are rated at 2 A, Reference 0.5 A 0.845 A Extender expansion NACs 0.75 A 1.28 A are rated 1.5 A (RAC current= 0.87 A 1.5 A actuator current) 1A 1.71A Wire Connections Screw terminals for input and output wiring, 18 to 12 AWG wire (0.82 mm2 to 3.31 mm2) Up to 2500 ft(762 m)from the IDNet communications source module IDNet Wiring Distance Reference Up to 10,000 ft(3048 m)total Class B wiring distance including T-Taps Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions See installation reference on page 8 Operating Temperature 32°to 120°F(0°to 49°C)indoor operation only Operating Humidity Range 10 to 90%RH at 90°F(32°C) Coil Supervision Module 2081-9046 Construction Epoxy encapsulated Dimensions 1-3/8"W x 2-7/16"L x 1-1/16"H(34 mm x 62 mm x 27 mm) Wiring 18 AWG(0.82 mm2)wire leads,color coded Current Rating 2 A maximum; internally fused at 3 A, non-replaceable *Refer to data sheet S4100-0040 for application information when using the Suppression Release Peripheral with the 4100U Series Fire Alarm Control Panels. Compatible UL Listed Valves and Actuators MFG. Model Number Coil Details MFG. Model Number *AUTOMAN II-C Assembly;solenoid 17728; 12 VDC,458 mA coil 25924 8210A107(097617-005D coil)1/2"NPS,5/8"orifice, 24 VDC AUTOMAN II-C Explosion-Proof Releasing 24 VDC,467 mA Device;solenoid 31492;coil 31438 8210G207(238310 coil)1/2"NPS, 1/2"orifice *AUTOMAN II-C Assembly;solenoid 68739; 12 VDC,458 mA 8211A107(097617-005D coil)24VDC A coil 25924, ASCO N Solenoid Electric Actuator;solenoid 73111; 24 VDC, 1 A HV2628571 (23810 coil)N.C. 1/2"NPS, 1/2"orifice s coil 73097 U *CV90 HF Electric Actuator 73327;may use 9 VDC max, HV2648581 (23810 coil)N.O. 1/2"NPS, 1/2"orifice L 73606 in-line resistor for 12 VDC 450 mA R8210A107(097617-005D coil)1/2"NPS,5/8"orifice LP CO2 w/ASCO solenoid 422934, 24 VDC,442 mA T8210A107(097617-005D coil) 1/2"NPS,5/8"orifice LP CO2 double action solenoid 430948 24 VDC,438 mA ECH Electrical Control Head(551201) LP CO2 3-way selector valve solenoid 24 VDC,438 mA PyrO Explosion-Proof Electric Actuator(570147) 433419 Chem Electric Actuator 24 VDC solenoid 570537 24 VDC,250 mA Removable Electric Actuator(570209)0.2 A Solenoid 26114002 for Solenoid Coupling LPG Assemblies:21006401 &21006402;& 24 VDC,542 mA LPG128/145/190/230-50/55 FM-200 valves; and LPG128-90UL iFLOW&FM-200 valves S 71395SN2ENJ1NOH111C2(Skinner coil H111C2)1/4",NPS, 1/16" 73212BN4TNOONOC111C2(Skinner coil C111C2)1/2",5-300 psi n 73212BN4TNLVNOC322C2(Skinner coil C322C2)1/2",NPS,0.92 A,250 psi n 73218BN4UNLVNOH111C2(Skinner coil H111C2) r 73218BN4UNLVNOC111C2(Skinner coil C111C2)1/2",NPS,5/8 in.orifice *12 VDC coils,either wire two in series for 24 VDC activation,or,if available from manufacturer,use series resistor 6 S4010-0003-5 6/2013 FM A• •roved Water Control Valves FM Manufacturer Model Number Details Group A Skinner LV2LBX25* 24 VDC, 11 W,458 mA, 1/2 inch NPS, 1/2 inch orifice T8210A107 B ASCO R8210A107 24 VDC, 16.8 W,700 mA, 1/2 inch NPS,5/8 inch orifice 8210A107 D ASCO 8210G207 24 VDC, 10.6 W,440 mA, 1/2 inch NPS, 1/2 inch orifice 73218BN4UNLVNOC111C2* 24 VDC, 10 W,420 mA, 1/2 inch NPS, 5/8 inch orifice E Skinner 24 VDC, 10 W,420 mA, 1/2 inch NPS, 5/8 inch orifice;5-300 psi rated 73212BN4TNOONOC111C2 working pressure F Skinner 73212BN4TNLVNOC322C2 24 VDC,22 W, 1/2 inch NPS, 920 mA,250 psi(1725 kPa), 1/2 inch orifice G Skinner 71395SN2ENJ1NOH111C2 24 VDC, 10 W,420 mA, 1/4 inch NPS, 1/16 inch orifice,250 psi (1725 kPa)rated working pressure Victaulic Series 753-E solenoid valve 24 VDC,8.7 W, 12 inch NPS,364 mA,300 psi(2069 kPa), 12 inch orifice 11591 and 11592 Normally closed(NC) J Viking Explosion proof solenoid valves,24 VDC, 10 W, 11595 and 11596 Normally open(NO) 12 inch NPS,300 psi(2069 kPa),4.1 Cv K Viking 11601 and 11602 NC solenoid valve,24 VDC,9 W, V2 inch NPS,250 psi(1725 kPa),6.2 Cv *For new applications, LV2LBX25 has been replaced by model number 73218BN4UNLVNOC111C2. 7 S4010-0003-5 6/2013 Suppression Release Peripheral Installation Reference Diagram 2975-9227 Box,red with white lettering(supplied with 4090-9006) / ... 0 '\ Door hinges on left and lifts off for access 3 4 Knockouts, one each side Door height Door screw ,, , ,, 0 8-1/8" ���, fastener (206 mm) , 4090-9812 LED indicator option(supplied with 4090-9006) T _ Door depth i F 4 1/2"(13 mm) �� Door width Box depth _� 6-1/8"(156 mm) �4"(102 mm) Box depth with door 4-1/16"(103 mm) 417; � 4090-9005 Suppression 3 411 � 3-'. Release Peripheral assembly I (supplied with 4090-9006) I ii3 7 ,� o O r" - .. Box height :::,111::, - I'f..:, , 8"(203 mm) 11 .,.�,.` I 0 9 Qo 1 ® 0 i 1: Box width 6"(152 mm) wl T1'('O,SIMPLEX,and the product names listed in this material are marks and or registered marks.Unauthorized use is strictly prohibited.NEPA 72 and National Fire Alarm and Signaling('ode are registered trademarks of the National Fire Protection Association(NEPA). 5®S i m p I Ex Tyco Fire Protection Products•Westminster, MA•01441-0001•USA S4010-0003-5 6/2013 www.simplexgrinnell.com c 2013 Tyco Fire Protection Products.All rights reserved All.spee canons and other information.shown were current as ofdocument revision date and are subject to change without notice. B®SimplEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors — Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories Features TrueAlarm analog sensing provides: :? 4,6 • Digital transmission of analog sensor values via IDNet ` or MAPNET II two-wire communications For use with the following Simplex®products: • 4100ES,4100U,4010ES,and 4010 Series control 1111 ;IC 111 .A1 panels;and 4008 Series control panels with reduced feature set(refer to data sheet S4008-0001 for details) • 4020,4100,and 4120 Series control panels,Universal Transponders,and 2120 TrueAlarm CDTs equipped 4098-9714 TrueAlarm Photoelectric for MAPNET II operation Sensor Mounted in Base Fire alarm control panel provides: • Peak value logging allowing accurate analysis of each Descri•tion sensor for individual sensitivity selection • Sensitivity monitoring satisfying NFPA 72 sensitivity Digital Communication of Analog Sensing. testing requirements;automatic individual sensor TrueAlarm analog sensors provide an analog calibration check verifies sensor integrity measurement digitally communicated to the host control panel using Simplex addressable communications.At the • Automatic environmental compensation,multi-stage control panel,the data is analyzed and an average value is alarm operation,and display of sensitivity directly in determined and stored.An alarm or other abnormal percent per foot condition is determined by comparing the sensor's present • Ability to display and print detailed sensor value against its average value and time. information in plain English language Intelligent Data Evaluation.Monitoring each sensor's Photoelectric smoke sensors provide: average value provides a continuously shifting reference • Seven levels of sensitivity from 0.2%to 3.7% point.This software filtering process compensates for (refer to additional information on page 3) environmental factors(dust,dirt,etc.)and component Heat sensors provide: aging,providing an accurate reference for evaluating new • Fixed temperature sensing activity.With this filtering,there is a significant reduction • Rate-of-rise temperature sensing in the probability of false or nuisance alarms caused by shifts in sensitivity,either up or down. • Utility temperature sensing • Listed to UL 521 and ULC-S530 Control Panel Selection.Peak activity per sensor is stored to assist in evaluating specific locations.The alarm General features: set point for each TrueAlarm sensor is determined at the • Listed to UL 268 and ULC-S529 host control panel,selectable as more or less sensitive as • Louvered smoke sensor design enhances smoke the individual application requires. capture by directing flow to chamber;entrance areas Timed/Multi-Stage Selection.Sensor alarm set points are minimally visible when ceiling mounted can be programmed for timed automatic sensitivity • Designed for EMI compatibility selection(such as more sensitive at night,less sensitive • Magnetic test feature is provided during day).Control panel programming can also provide • Different bases are available to support a supervised multi-stage operation per sensor.For example,a 0.2% or unsupervised output relay,and/or a remote LED level may cause a warning to prompt investigation while a alarm indicator 2.5%level may initiate an alarm. Additional base reference: Sensor Alarm and Trouble LED Indication.Each • For isolator bases,refer to data sheet S4098-0025 sensor base's LED pulses to indicate communications • For sounder bases,refer to data sheet 54098-0028 with the panel.If the control panel determines a sensor is • For photo/heat sensors,refer to data sheet S4098-0024 in alarm,or is dirty or has some other type of trouble,the (single address)and S4098-0033(dual address) details are annunciated at the control panel and that sensor base's LED will be turned on steadily.During a system • These products have been approved by the California State Fire Marshal(CSFM)pursuant to alarm,the control panel will control the LEDs such that Section 13144.1 of the California Health and Safety Code.See CSFM Listings an LED indicating a trouble will return to pulsing to help 7272.0026:218,7271.0026:231,7270-0026:216,and 7300-0026:217 for allowable values g p g p and/or conditions concerning material presented in this document,Accepted for use—City of identify the alarmed sensors. New York Department of Buildings—MEA35-93E.Additional listings may be applicable, contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S4098-0019-17 3/2014 TrueAlarm Sensor Bases and Accessories Descri•tion Sensor Base Features TrueAlarm sensor bases contain integral addressable Base mounted address selection: electronics that constantly monitor the status of the Address remains with its programmed location detachable photoelectric or heat sensors.Each sensor's • output is digitized and transmitted to the system fire alarm • Accessible from front(DIP switch under sensor) control panel every four seconds. General features: • Automatic identification provides default sensitivity when Since TrueAlarm sensors use the same base,different substituting sensor types sensor types can be easily interchanged to meet specific • Integral red LED for power-on(pulsing),or alarm or trouble location requirements.This feature also allows intentional (steady on) sensor substitution during building construction.When • Locking anti-tamper design mounts on standard outlet box conditions are temporarily dusty,instead of covering the • Magnetically operated functional test smoke sensors(causing them to be disabled),heat sensors may be installed without reprogramming the control Sensor Bases panel.Although the control panel will indicate an incorrect sensor type,the heat sensor will operate at a 4098-9792,Standard Sensor Base default sensitivity providing heat detection for building 4098-9789,Sensor Base with wired connections for: protection at that location. • 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Mountin• Reference Supervised Relay Bases(not compatible with 2120 CDT): • 4098-9791,4-Wire Sensor Base,use with remote or Electrical Box Requirements:(boxes are by others) locally mounted 2098-9737 relay,requires separate 24 VDC Without relay in the b :4"octagonal or 4"square,1-1/2"deep; • 4098-9780,2-Wire Sensor Base,use with remote or single gang,2"deep locally mounted 4098-9860 relay,no separate power With relay in the 42:4"octagonal or 4"square,1-1/2"deep, required with 1-1/2"extension ring • Supervised relay operation is programmable and can be 4"(102 mm)Square Box 4"(102 mm)Octagonal Box manually operated from control panel Surface mount referenc- • Includes wired connections for remote LED alarm indicator >•._► t or 4098-9822 relay(relay is unsupervised and requires EN separate 24 VDC) { C C Sensor Base 0•tions 1-1/2"(38 mm) 2098-9737,Remote or local mount supervised relay: minimum box depth Flush mount reference,mount even with final • DPDT contacts for resistive/suppressed loads,power limited surface,or with up to 1/4"(6.4 mm)maximum recess rating of 3 A @ 28 VDC;non-power limited rating of 3 A @ 120 VAC(requires external 24 VDC coil power) 2098-9737 Supervised Relay 4098-9822 Relay(mounts (mounts in base electrical box or in base electrical box) 4098-9860, Remote or local mount supervised relay: remotely) • SPDT dry contacts,power limited rating of 2 A @ 30 VDC, resistive;non-power limited rating of 0.5 A @ 125 VAC, resistive Relay Size: 2-1/2"X 1-1/2"X 1" 4098-9822,LED Annunciation Relay: (3.75 in3)(64 mm X 38 mm X 25.4 mm) • Activates when base LED is on steady,indicating local alarm or trouble 4098-9860 Supervised Relay(mounts in base • DPDT contacts for resistive/suppressed loads,power limited elecical .4x or remotely;X31.8 m2X 8 X 1-1/4"X 11/32" a (1 in3)(60.4mmX31.8mmX8.6mm) f/ rating of 2 A @ 28 VDC;non-power limited rating of 1/2 A @ 120 VAC,(requires external 24 VDC coil power) NOTE:Review total wire count,wire size,and accessories being 4098-9832,Adapter plate: wired to determine required box volume. • Required for surface or semi-flush mounting to 4"square electrical box and for surface mounting to 4"octagonal box 1' 6-3/8"(162 mm) • Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product ^ 1/4" 409 unting Adapter Plate,mouted,boxred for mounting to surface mounted boxes 2098-9808,Remote red LED Alarm (6.4 mm) awn 4 square flush 1z4x Indicator: i~-4-7/8"(124 mm)-Ml • Mounts on single gang box(shown in 15/16„ illustration to right) ALARM o (24 mm) \ 0 / TrueAlarm Bases EP Si 4098-9780,4098-9789,4098-9791,&4098-9792 mplex / \ 2 S4098-0019-17 3/2014 TrueAlarm Sensors Features 4098-9733 Heat Sensor Sealed against rear air flow entry TrueAlarm heat sensors are self-restoring and provide rate Interchangeable mounting compensated,fixed temperature sensing,selectable with EMI/RFI shielded electronics or without rate-of-rise temperature sensing.Due to its Heat sensors: small thermal mass,the sensor accurately and quickly • Selectable rate compensated,fixed temperature measures the local temperature for analysis at the fire sensing with or without rate-of-rise operation alarm control panel. • Rated spacing distance between sensors: Rate-of-rise temperature detection is selectable at the control panel for either 15°F(8.3°C)or 20°F(11.1°C) Fixed Temp. UL&ULC FM Spacing,Either Fixed per minute.Fixed temperature sensing is independent of Setting Spacing Temperature Setting rate-of-rise sensing and programmable to operate at 135°F 60 ft x 60 ft 20 ft x 20 ft(6.1 m)for fixed 135°F(57.2°C)or 155°F(68°C). In a slow developing - (57.2°C) (18.3 m) temperature only;RTI=Quick 50 ft x 50 ft(15.2 m)for fixed fire,the temperature may not increase rapidly enough to 155°F 40 ft x 40 ft temperature with either rate-of-rise operate the rate-of-rise feature.However,an alarm will be (68°C) (12.2 m) selection;RTI=Ultra Fast initiated when the temperature reaches its rated fixed Smoke Sensors: temperature setting. • Photoelectric technology sensing TrueAlarm heat sensors can be programmed as a utility • 360°smoke entry for optimum response device to monitor for temperature extremes in the range from 32°F to 155°F(0°C to 68°C).This feature can • Built-in insect screens provide freeze warnings or alert to HVAC system problems.Refer to specific panels for availability. 4098-9714 Photoelectric Sensor -7/8"(124 mm TrueAlarm photoelectric sensors use a stable,pulsed infrared LED light source and a silicon photodiode D"—LED status indicator receiver to provide consistent and accurate low power 2-3/8" smoke sensing. Seven levels of sensitivity are available (60 mm) for each individual sensor,ranging from 0.2%to 3.7%per —��.....----- foot � foot of smoke obscuration. Sensitivities of 0.2%,0.5%, I illi_ �I�_��� and 1%are for special applications in clean areas. `II7 Standard sensitivities are 1.5%,2.0%,2.5%,3.0%,and 3.7%.Application type and sensitivity are selected and 4098-9733 Heat Sensor with Base then monitored at the fire alarm control panel.* The sensor head design provides 360°smoke entry for WARNING: In most fires, hazardous levels of smoke optimum response to smoke from any direction.Due to its and toxic gas can build up before a heat detection photoelectric operation,air velocity is not normally a device would initiate an alarm. In cases where Life factor,except for impact on area smoke flow. Safety is a factor,the use of smoke detection is highly recommended. 7 •-7/8"(124 mm) 0 —LED status indicator Application Reference 2-1/8" (54 mm) Sensor locations should be determined only after careful 1 ............. consideration of the physical layout and contents of the .,,,,-/; area to be protected.Refer to NFPA 72,the National Fire Alarm and Signaling Code.On smooth ceilings,smoke 4098-9714 Photoelectric Sensor with Base sensor spacing of 30 ft(9.1 m)may be used as a guide.* *For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-17 3/2014 TrueAlarm Analo• Sensin• Product Selection Chart TrueAlarm Sensor Bases(for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model Description Compatibility Mounting Requirements 4098-97924"octagonal or 4"square box, 1-1/2"min. Standard Sensor Base No options depth;or single gang box,2"min.depth Sensor Base with connections for 2098 9808 Remote Alarm Indicator or 4098-9789 Remote LED Alarm Indicator or 4098-9822 Unsupervised Relay 4"octagonal or 4"square box Unsupervised Relay 4-Wire Sensor Supervised Relay 2098-9737 Supervised Remote Relay Note:Box depth requirements depend on 4098-9791** Base with connections for LED 2098-9808 Remote Alarm Indicator or total wire count and wire size,refer to Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay accessories list below for reference. 2-Wire Sensor Supervised Relay 4098-9860 Supervised Remote Relay **NOTE:4098-9791 and 4098-9780 are NOT 4098-9780** Base with connections for LED 2098-9808 Remote Alarm Indicator or compatible with the 2120 CDT Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay TrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714 Photoelectric Smoke Sensor Bases 4098-9792,4098-9789, 4098-9733 Heat Sensor 4098-9791,and 4098-9780 Refer to base requirements TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements Supervised Relay,mounts remote or in base Remote Mounting requires 4"octagonal 2098-9737 electrical box For use with 4098-9791 base or 4"square box, 1-1/2"minimum depth 4098-9860 Supervised Relay,mounts remote or in base For use with 4098-9780 base Base Mounting requires 4"octagonal electrical box box,2-1/8'deep with 1-1/2"extension ring 2098-9808 Remote Red LED Alarm Indicator on single Bases 4098-9789,4098-9791, Single gang box, 1-1/2"minimum depth gang stainless steel plate and 4098-9780 4098-9822 Unsupervised Relay,tracks base LED status; Bases 4098-9789,4098-9791, 4"octagonal box,2-1/8"deep with 1-1/2" Note:Mounts only in base electrical box and 4098-9780 extension ring Bases 4098-9792,4098-9789, Required for surface or semi-flush 4098-9832 Adapter Plate 4098-9791,and 4098-9780 mounted 4"square box and for surface mounted 4"octagonal box S•ecifications General Operating Specifications Communications and Sensor Supervisory Power MAPNET II or IDNet,auto-select,24-40 VDC w/data,400µA typical, 1 address per base Communications Connections Screw terminals for in/out wiring,18 to 14 AWG(0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical,no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG(0.82 mm2) UL Listed Operating Temperature Range 32°to 100°F(0°to 38°C) Operating Temperature with 4098-9733 Heat Sensor 32°to 122°F(0°to 50°C) Range with 4098-9714 Smoke Sensor 15°to 122°F(-9°to 50°C) Storage Temperature Range 0°F to 140°F(-18°C to 60°C) Humidity Range 10 to 95%RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/min(0-1220 m/min) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737(see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) Supervisory Current 270µA,from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA,from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860(see page 2 for contact ratings) Power Supplied from communications 4098-9822 Unsupervised Relay,Requirements for Bases 4098-9789.4098-9791,and 4098-9780(see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TYCO,SIMPLEX,and the product names listed in this material are marks and or registered marks.Unauthorized use is strictly prohibited.NEPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association(NFI'A). 5®S i m p I Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4098-0019-17 3/2014 www.simplex-fire.corn tr 2014 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. EtSimplex Releasing System Peripherals UL, ULC, CSFM Listed; Fire Suppression System Abort Switches and Releasing MEA (NYC) Acceptance* Appliance Circuit (RAC) Maintenance Switches Features _ Abort switches provide a manual Fire Suppression • System release abort request: • Pushbutton momentary switch is mounted on a stainless steel single-gang plate FIRE SUPPRESSION A protruding collar protects the switch from SYSTEM ABORT • accidental contact(collar is removable if required) • Available flush or surface mount • Flush mounting requires standard single-gang box ,' • Surface mounting includes a red mounting box • Models are available with internal 1.2 k)2 resistor for PUSH AND HOLD current limited operation 0 Maintenance switches provide a secure and visible e51""''•" disconnect means for servicing Fire Suppression System Releasing Appliance Circuits(RACs): Abort Switch (shown 1/2 size) • Maintainedosition keyswitch is mounted on a P Y stainless steel double-gang plate • Key is removable only in the normal position • Disabled position opens connection to output circuit and places a 16.2 k52 resistor across the input circuit to initiate a supervisory condition at the host panel • Disconnect indicator lamp is a bright incandescent bulb with red lens,powered from separate 24 VDC NORMAL • Available for flush or surface mount • Flush mounting requires a standard double-gang box asc/ O • Surface mount models includes a red mounting box j�asset E UL listed to Standard 864 ARE SUPPRESSION Descri•tion DISCONNECT/DISABLE CID Releasing systems typically require maintenance disconnect ® Li Simplex switches and often require abort switches.These abort and maintenance switches are clearly labeled and combine easy Maintenance Switch with Disconnect Indicator Lamp operation with rugged construction for high integrity (shown 1/2 size) operation. • Refer to page 2 for specific product listings.NOTE:MEA is not applicable to Maintenance Switches.FM is not applicable to Abort Switches. As indicated on page 2,these products have been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7300-0026:313 for allowable values and/or conditions concerning material presented in this document.Abort switches are accepted for use-City of New York Department of Buildings-MEA35-93E.Maintenance switches were not approved by FM as of document revision date.Additional listings may be applicable,contact your local Simplex® product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S2080-0010-3 10/2013 Product Selection (see pa•e 3 for specifications) Abort Switches Model Description Listing Status Details 2080-9056 Flush mount UL, ULC, &CSFM listed; MEA(NYC) Single-gang size; includes 3 position contact block housing 2080-9057 Surface mount; includes with one contact block installed red mounting box Acceptance Abort Switches for 4004R Series Suppression Release Panel Current Limited Operation Model Description Listing Status Details 2080-9067 Flush mount UL, ULC, &CSFM Single-gang size; includes 1.2 kn, 1W resistor for current Surface mount; includes listed; MEA(NYC) limited operation and 3 position contact block housing with 2080-9068 red mounting box Acceptance one contact block installed Maintenance Switches with Disconnect Indicator Lamp Model Description Listing Status Details 2080-9059 Flush mount Double-gang size; includes 3 position contact block housing UL, ULC, &CSFM with 2 contact blocks installed;disabled position opens 2080-9060 Surface mount; includes listed connection to output and places a 16.2 kS2 resistor across the red mounting box input circuit; resistor is removable if required for retrofit Accessories for Field Installation Model Description 2080-9061 Additional Contact Block for Abort or Maintenance Switch; 1 Form C contact; UL recognized component for use with these switches; listings and approvals are not applicable Abort Switch Installation Reference Red box is supplied with surface mount Abort Switch 2080-9057 or 2080-9068 • Box width 3"(76 mm) 2-1/4"(56 mm)into box FIRE SUPPRESSION 1/2 "li".11.11114 -- SYSTEM ABORT Abort Switch (13 mm) height 4-1/2" (114 mm) Box height 4-13/16" (122 mm) Switch recess depth 5/32" PUSH AND HOLD (4 mm) 0Simmplex Removable collar Abort Switch � width,2-3/4"(70 mm) (70 mm) Supplied gasket attaches to box; NOTE: For flush mounting,use field installed for flush mount; a 2-3/4"deep(70 mm) pre-attached for surface mount single-gang box 2 S2080-0010-3 10/2013 Maintenance Switch Installation Reference Red box is supplied with surface mount Maintenance Switch 2080-9060 Box dimensions 4-13/16"(122 mm)square 2-1/4"(56 mm)into box 4-1/2" ---- 0 NORMAL (114 mm) DSCSAJ DIBLE FIRE SUPPRESSION DISCONNECT 1 DISABLE Simplex ® ® r Maintenance Switch 2-3/4" width 4-9/16"(116 mm) • (70 mm) Supplied gasket attaches to box; NOTE: For flush mounting,use field installed for flush mount; a 2-3/4"deep(70 mm) pre-attached for surface mount double-gang box S•ecifications Electrical Ratings Abort Switch; One Contact block Silver contacts; 1 N.O. & 1 N.C.; rated 2 A resistive @ 30 VDC Maintenance Switch with Lamp; Circuit control: Silver contacts; 1 N.O. & 1 N.C.; rated 2 A resistive @ 30 VDC Two Contact blocks Lamp control: Silver contacts; 1 Form C; rated 2 A resistive @ 30 VDC Maintenance Switch Indicator Replaceable 2 W incandescent bulb; 24 to 30 VDC typical; 83 mA @ 24 VDC; requires Light(models 2080-9059 and separate 24 VDC 2080-9060) Wiring Connections Abort Switch Terminal blocks for in/out wiring; 18 to 14 AWG wire(0.82 mm2 to 2.08 mm2) Abort Switch with Current Limited Terminal blocks for first wire connection; 18 to 14 AWG wire(0.82 mm2 to 2.08 mm2); Resistor 18 AWG wire lead for second wire connection Maintenance Switch 18 AWG (0.82 mm2)color coded wire leads for suppression circuit terminal blocks for lamp wiring; 18 to 14 AWG wire(0.82 mm2 to 2.08 mm ) Additional Information 579-416, Installation Instructions Environmental Ratings Temperature Range 32°F to 120°F(0°C to 49°C) Humidity Range Up to 93%at 90°F(32° C) 3 S2080-0010-3 10/2013 TYCO,SIMPLEX,and the product name.slisted in this material are marks and or registered marks.Unauthorized use is strictly prohibited. ®Sim p 1 Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S2080-0010-3 10/2013 www.sin plexgrinnell.cow Cc 2013 Tyco Fire Protection Products.All rights reserved All specifications and other information shown were current as of document revision date and are.subject to change without notice. ®SimpIEx Releasing System Peripherals UL, ULC, CSFM Listed; FM Approved; IDNet or MAPNET II Communicating Devices; MEA (NYC) Acceptance* Addressable Manual Stations for Releasing Applications Features Individually addressable manual fire alarm 4,4 stations for releasing applications with: ( .- ' (� .s. v • Power and data supplied via IDNet or MAPNET II �`./ wiz ,aip A', addressable communications using a single wire pairPUSH ? 41' III • Operation that complies with ADA requirements - • Pull lever that protrudes when alarmed PULL DOWN1 • Break-rod supplied(use is optional) ,; 2,1 v Wr ' • Dual action push and pull operation • Label kit provides for six varieties of releasing applications(ordered separately) Compatible with the following Simplex®Releasing10 f 4.0 System control panels equipped with either IDNet ' � or MAPNET II communications: 4099-9012 Addressable Manual Station for Releasing • Model Series 4100ES,4010ES,and 4010 Applications(front and side view) • Installed 4100,4120,and 4020 systems Compact construction: • Electronics module enclosure minimizes dust infiltration • Allows mounting in standard electrical boxes P • Screw terminals for wiring connections §.;11544104; Tamper resistant reset key lock _ • Locks are keyed the same as Simplex fire alarm cabinetsV:.,'4'1":,'z;'',''''''';:linittitior. :- .',i ' Multiple mounting options: '. . • Surface or semi-flush with standard boxes or matching Simplex boxes Label Kit • Flush mount adapter kit 4099-9802 • Adapters are available for retrofitting to commonly available existing boxes 0•eration UL listed to Standard 38 Activation requires that a spring loaded interference Descri•tion plate(marked PUSH)be pushed back to access the station pull lever with a firm downward pull that activates the These 4099 series addressable manual stations combine alarm switch.Completing the action breaks an internal the familiar Simplex housing with a compact plastic break-rod(visible below the pull lever,use is communication module providing easy installation for optional).The use of a break-rod can be a deterrent to _ releasing applications. The integral individual addressable vandalism without interfering with the minimum pull module(IAM)monitors status and communicates changes requirements needed for easy activation.The pull lever to the connected control panel via MAPNET II or IDNet latches into the alarm position and remains extended out communications wiring. of the housing to provide a visible indication. A blank area on the front of the station allows the Station reset requires the use of a key to reset the selection of a label to match the specific releasing manual station lever and deactivate the alarm switch.(If application(label kit is ordered separately).(Refer to data the break-rod is used,it must be replaced.) sheet S4099-0001 for standard Simplex addressable Station testing is performed by physical activation of manual stations.) the pull lever.Electrical testing can be also performed by This product has been approved by the California State Fire Marshal(CSFM)pursuant to unlocking the station housing to activate the alarm switch. Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7150-0026:224 for allowable values and/or conditions concerning material presented in this document. Accepted for use—City of New York Department of Buildings—MEA35-93E.Additional listings may be applicable;contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. S4099-0002-2 6/2013 Addressable Manual Station Product Selection Addressable Manual Stations Model Description 4099-9012 Double action, Push operation,Addressable manual station; red housing with white letters and white pull lever; requires label kit 4099-9802 4099-9802 Label kit,white lettering on red background; select the label required for the specific releasing application; types include: Clean Agent, Extinguishing, Carbon Dioxide, Foam System, Sprinkler, and Manual Accessories Model Description Reference - 2975-9178 Surface mount steel box, red 2975-9022 Cast aluminum surface mount box, red Refer to page 3 for dimensions _ 2099-9813 Semi-flush trim plate for double gang switch box, red 2099-9814 Surface trim plate for Wiremold box V5744-2, red Typically for retrofit, refer to page 4 2099-9819 Flush mount adapter kit, black 2099-9820 Flush mount adapter kit, beige Refer to page 4 for details 2099-9804 Replacement break-rod S•ecifications MAPNET IIIDN r addressr Power and Communications o et, 1 per station, up to 2500 ft(762 m)from fire alarm control panel, up to 10,000 ft(3048 m)total wiring distance(including T-Taps) Address Means Dipswitch,8 position Wire Connections Screw terminal for in/out wiring,for 18 to 14 AWG wire Metric wire equivalents: 18 AWG=0.82 mm2; 14 AWG=2.08 mm2 UL Listed Temperature Range 32°to 120°F(0°to 49°C)intended for indoor operation Humidity Range Up to 93%RH at 100° F(38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5"H x 3-3/4"W x 1" D(127 mm x 95 mm x 25 mm) Installation Instructions 574-332 Addressable Manual Station Semi-Flush Mounting Single Gang Box Mount 4"Square Box Mount Single gang box,2-1/2"deep 4"(102 mm)square box,2-1/8"(54 mm)minimum (64 mm),RACO#500 or equal depth,RACO#231 or equal(supplied by others) (supplied by others) AIMIMIIIiirO 0 Mount flush or with ) C0 maximum extension 1 DO NOT RECESS 4"Square box o (with cover plate - J � 1 /c--) / 48U /A I II.Station FIRE ® ALARM side view PUSH Single gang cover plate,3/4" (19 mm)extension,RACO#773 PULL DOWN 1 or equal(supplied by others) I Single gang ♦' box outline M__,■ Wall surface Semi-Flush Mount Side View OSimplex na SZ 2 S4099-0002-2 6/2013 Addressable Manual Stations Surface Mountin. 2975-9178 Box 2975-9022 Cast Box Preferred Mounting.For 5-3/16"H x 4"W x 2-3116"D 5"H x 3-7/6"W x 2-3/16"D Surface mounting of these (132 mm x 102 mm x 56 mm) (127 mm x 98 mm x 56 mm) (ordered separately) (ordered separately) addressable manual stations,the preferred electrical boxes are show � ' shownin the illustration to the lib right. ' 0 - Additional Mounting Knockouts located Reference.Refer to page 4 for top and bottom Wiremold box mounting - compatibility. FIRE OARMl 0 AIMPU ��o PULL DOWN li Access for 3/4"threaded 5" conduit located top and bottom (127 mm) SimPlex MANUAL RELEE 1"(25.4 mm) u3-3/4"(95 mm)-0.1 4099 Series Addressable Manual Station Surface Mount Side View with Internal Detail 1-1/4" ki(32 mm)_ Simplex 2975-9178 box Field wiring (shown for reference) (shown for reference) a'3 Address setting under resealable label(accessible with cover open) : 2-5/8" > (67 mm) - Station cover hinges open for C . la installation access C 'rW ,,, ) Switch wiring ;', (prewired) 3 S4099-0002-2 6/2013 Addressable Manual Station, Additional Mounting Information For retrofit and new installations,additional compatible mounting boxes o 0 and the required adapter plates s ' Wiremold Ao m- receptacle box are shown in the illustration to 2099-9814 Surface trim model V5744-2 the right. for Wiremold box (supplied by 5-1/8"H x 5"W others) (130 mm x 127 mm) O O O S O Two gang switch box,each 3"H x 2"W x 2-3/4"D (76 mm x 51 mm x 70 mm) (supplied by others) PUSH n 1 /) 6O0 n /c v / 2099-9813 Semi-flush trim for O E= U / 2-gang switch box,6"H x 4-1/2"W (152 mm x 114 mm) - Addressable Manual Station, Flush Mountin. Information Flush mount adapter kit 2099-9819,Black 2099-9820,Beige • 0' � £ V ' m Box must be recessed into wall t-?1W „*` r``Sfib , ^ra yate k- , ' ' , ti 1"to 1-1/8"(25.4 mm to 29 mm) Riika �'F yam . .; -_ ,, f 0105 impiElogrpg40:41.0.wggiaN win 8" PUSH o (203 mm) Hole cutout must be a OM PULL DQ'?'\ minimum of 6"H by s"w O 6� WORM �,' ::. (152 4 (152 mm by 127 mm) mm) " 0 Pit 4:11, IN'11131 leA111.1r,::: 1111111 rra O ,42.00 �.� oeefiglA rW,.4,e',4CT,:tvf.AViiiiiikii0;i045.4. MOO 'c'. _ 0 Milingi �� 4-11/16"(119 mm) .. `�Y• 41 square box,2-1/8" (54 mm)minimum • *�4 . Wall depth(by others) 4-3/4"(121 mm) surface F. 6-3/4"(171 mm) Front View Side View TYCO,SIMPLEX,and the product names listed in this material are marks and or registered marks.Unauthorized use is strictly prohibited.Lexan is a trademark of the General Electric Co.Wiremold is a trademark of the Wiremold Company. f®Sim p 1 EX Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4099-0002-2 6/2013 www.simp/exgrinnell.com 0 2013 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without nonce. ®Simplex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNetTM and MAPNET II® Communicating Devices, MEA (NYC) Acceptance* Individual Addressable Modules (IAMB) Features 1 ZDNet or MAPNET II addressable communications . t supply both data and power over a single wire pair sINVEEt mME N 3 e 0 to provide**: 4090-9001 S nE4,ISED uw • Supervised Class B monitoring of normally open,dry IN®l,INN su 331 DATE CODE: 1 contacts M®0 • Total wiring distance from IAM to supervision resistor(s)of up to 500 ft(152 m) 1 00000000 • Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications 4090-9001 Supervised IAM • For use in indoor locations up to 158°F(70°C)such as (shown approximately 3/4 size) attic spaces or similar applications For use with following Simplex control panels: • Model Series 4008,4010,4010ES,4100U and 4100ES fire alarm control panels for IDNet communications • Model Series 4100/4100U/4100ES,4120,4020,and # 2120 Communicating Device Transponders(CDTs) equipped with MAPNET II communications Model 4090-9001:• Enclosed design minimizes dust infiltration • Mounts in standard single gang electrical box P!t" ,' • Screw terminals for wiring connections • Visible LED flashes to indicate communications • Optional covers are available to allow LED to be 4090-9051 Supervised IAM viewed after installation(requires mounting bracket, (shown approximately 3/4 size) ordered separately) Model 4090-9051: • Encapsulated design for extended exposure to high Descri•tion humidity(LED is not present on this model) • Color coded 18 AWG leads for wiring Individual addressable modules(IAMs)receive ZDNet communications provides current limited both power and communications from a two wire monitoring: MAPNET II or IDNet circuit.They provide location • Provides monitoring of tamper switch(supervisory) specific addressability to a single initiating device(such and waterflow switch(alarm)on same circuit using as single station smoke detector alarm contacts or heat detector contacts)or multiple devices at the same location one point by monitoring normally open dry contacts and the wiring • Available with IDNet communications only to an end-of-line resistor. Multiple operation modes are available and are selectable at the control panel: Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a • Contact closure status can be tracked status indicating LED. • Momentary contact closure conditions can be selected at the panel to be latched or tracked(not available with the Model 4090-9051 is an encapsulated package with wire 2120 CDT) leads.It does not provide a status indicating LED. UL listed to Standard 864 • These products have been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document.It is subject to re-examination,revision,and possible cancellation.Accepted for use—City of New York Department of Buildings—MEA35-93E.Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. S4090-0001-10 Operation Current Limited Operation Applications Contact Closure.Closure of the monitored contact(s) For use with IDNet communications only,these initiates an alarm or other response as programmed at the IAMs can provide quad-state sensing of normal,open fire alarm control panel. An open in the monitored circuit circuit,short circuit,and current limited conditions. wiring will cause a trouble to be reported. (Program type is"T-sense.")With the proper end-of-line Panel Selections. Selections can be made at the control and current limiting resistors,dual functions such as panel to maintain the alarm condition if the initiating tamper switch and waterflow switch monitoring can be device contacts are momentary,such as from a determined and communicated by a single addressable rate-of-rise heat detector,or to track the device contact point. status(not available with the 2120 CDT). IAM Product Selection Model Description 4090-9001 Supervised IAM,mounted in thermoplastic housing with screw terminals;see applicable options below 4090-9051 Supervised IAM,encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mounting screws;galvanized steel 4090-9810 Mounting bracket,mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. Description 4081-9004 733-886 6.8 k4, 1/2 W;Standard end-of-line resistor harness for N.O.contact supervision 4081-9003 733-896 4.7 kb2, 1/2 W Use for current limited monitoring applications 4081-9005 733-984 1.8 kc2, 1/2 W S•ecifications Electrical Power and Communications MAPNET II or IDNet,auto selected, 1 address per IAM Input Requirements Normally open,dry contacts 4090-9001 Screw terminals for in/out wiring, 18 to 14 AWG wire Wire Connections (0.82 mm2 to 2.08 mm2) 4090-9051 Color coded wire leads, 18 AWG(0.82 mm2),8"long(203 mm) Installation Instructions 574-331 for 4090-9001;579-572 for 4090-9151 Reference Documents Field Wiring Diagrams 842-073 for IDNet operation;841-804 for MAPNET II operation Wiring Distances 500 ft(152 m)maximum without protectors Distance from IAM to Contacts 400 ft(122 m)maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or 2500 ft(762 m)maximum from fire alarm control panel IDNet Communications 10,000 ft(3048 m)maximum total wiring distance(including T-Taps) Mechanical 4090-9001 1-9/16"W x 1-3/4"H x 1-1/4"D(40 mm x 44 mm x 32 mm) Dimensions 4090-9051 1-9/16"W x 1-9/16"H x 9/16"D(40 mm x 40 mm x 14 mm) Housing Material,4090-9001 Black thermoplastic Encapsulation Material,4090-9051 Epoxy, beige Temperature Range 32°to 158°F(0°to 70°C); intended for indoor operation Humidity Range Up to 93%RH at 100°F(38°C) 2 S4090-0001-10 Mountin• Information 4090-9001 IAM ! I__`_/ Field wiring shown supervised IAM / for reference p II -•tL's!s7, S �_ lPpLINn� Op /w, dA 0 '' I ,� ill DI fL E CODE rill LED viewing port ,i I���'p►�;•— Single gang electrical �`a�_'O box 2-1/2"(64mm) minimum depth (supplied by others) Address setting under resealable label b . Single gang blank cover plate and mounting screws,for use when LED is not required to be externally viewed(supplied by others) Mounting Reference, Single Gang Blank Cover Plate • !J n 1 \, O O /I. Light pipe for C T1 J LED viewing ie 4-1/4" r — 4-1/2" (108 mm) .' � (114 mm) i C 0 O O O i V J V 2-1/2" 2-13/16" (64 mm)� 14 (72 mm) �� 4090-9806, Trim plate for 4090-9807, Trim plate for 4090-9810 Mounting semi-flush mounted box surface mounted box bracket, ordered separately NOTE:These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 3 S4090-0001-10 4090-9051 Mountin• Information Address setting is °1111100111110 at rear of housing - 4:4 01 4090-9051 I' Encapsulated 1111Supervised IAM „ Ii 0 ,su:„0 C•��o Single gang electrical box 2-1/2"(64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws(supplied by others) Tyco is a registered trademark of Tyco International Services GmhH and is used under license.Simplex,the Simplex logo,ZDNet,and MAPNET II are trademarks of Tyco International Ltd.and its affiliates and are used under license. f3 S i m p I Ex SimplexGrinnell LP Westminster•Westminster,MA•01441-0001•USA S4090-0001-10 ® www.simplexgrinnell.com CO 2011 Tyco.All rights reserved.All specifications and other information.shown were current as ofdocument revision date and are.subject to change without notice. E®Simplex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNet Communicating Devices MEA (NYC) Acceptance* Model 4090-9002 Relay IAM Features Individual Addressable Relay Module(Relay IAM): p "° p • IDNet addressable control for use with Simplex®fire alarm control panel models 4100ES,4010ES,4100U, L J 4008,and 4010 • A single addressable point provides control and status e - tracking of a Form"C"contact - 11 ® Mil 181110 It • Low power latching relay design allows IDNet 40)0.10020 QUI ION! communications to supply both data and module power ;A ,,, •F m uenoa • Relay is set to OFF on initial power up and upon loss of [i __ 1 ZDNet communications (� O O Compact,sealed construction: l� • Enclosed design minimizes dust infiltration • Mounts in standard 4"(102 mm)square electrical box, 4090-9002 IDNet Relay IAM Package optional adapter bracket is available to mount in a (shown approximately 1/2 size) 4 tt/16"(119 mm)square electrical box S•ecifications • Screw terminals for wiring connections • Visible LED flashes to indicate communications Communications IDNet communications, 1 address per • Optional covers are available to allow LED to be device viewed after installation Relay IAM Power Supplied by IDNet communications UL listed to Standard 864 Contact Ratings*(not rated for incandescent switching) Type Form C, SPDT Descri•tion 2 A @ 24 VDC,resistive from listed Power-Limited - fire alarm IDNet Relay IAMs allow fire alarm control panels to 1 A @ 24 VDC,inductive supply control a remotely located Form"C"contact using IDNet addressable communications for both data and module Nonpower-Limited 0.5 A @ 120 VAC, resistive power.Typical applications would be for switching local * Provide circuit fusing and transient suppression as power for control functions such as elevator capture,or required per application. DC inductive loads can typically control of HVAC components,pressurization fans, be diode suppressed; 120 VAC loads may require RC dampers,etc.Relay status is also communicated requiring networks or varistors,depending on device type. Refer to the installation instructions for additional information. only one device address. Wire Connections Screw terminals for in/out wiring, Product Selection 18 to 14 AWG wire(0.82 to 2.08 mm2) Up to 2500 ft(762 m)from control Model Description panel 4090-9002 Relay IAM IDNet Up to 10,000 ft(3048 m)total wiring Communications distance(including T-Taps) Optional Adapter and Trim Plates Wiring Reference Compatible with Simplex 2081-9044 Model Description Overvoltage Protectors 4090-9813 Adapter plate to fit 4 11A6"(119 mm)square 4 i8"H x 4%a"W x 1 %"D electrical box Dimensions (105 mm x 105 mm x 35mm) 4090-9801 For semi-flush Trim Plate,galvanized Housing Material Black thermoplastic mounted box steel,with LED viewing Mounting Plate Sheet metal,galvanized For surface window;includes 4090-9802 mounted box mountingscrews Temperature 32°to 120°F(0°to 49°C), Range intended for indoor operation • This product has been approved by the California State Fire Marshal(CSFM)pursuant to Humidity Range Up to 93%RH at 100°F(38°C) Section 13144.1 of the California Health and Safety Code.See CSFM Listing Installation 7300-0026:223 for allowable values and/or conditions concerning material presented in this 574-184 document.Accepted for use—City of New York Department of Buildings—MEA35-93E. Instructions Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S4090-0002-9 11/2013 Rela IAM Mountine Information e CD 0 _ A 11100100.1 0 Address setting under resealable label ^ 11111111-1j: 0 , .,... 0 •. ,...... .,c. e l ""11114t444400,01101: - . i .. ' t ----- 4"(102 mm)square box,2-1/8" *t)---. ' (54 mm)minimum depth,RACO 232 or equal(supplied by others) 4090-9002 Relay IAM ( ;1 , -41----, .0 Double gang blank cover plate and mounting screws,for rs_n., use when LED is not required to be externally viewed ---- (supplied by others) Mounting Reference, Double Gang Blank Cover Plate A All, Ilik ,. © © 1 © © Light pipe for LED viewing 4-9/16" 4-5/16" (116 nim) (109 mm)• ^ © © © © -, , v -9/16"(116 mm) lb I 1-41 4-5/16"(109 mm) IP I 4090-9801,Trim plate for 4090-9802,Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO,SIMPLEX,and the product names listed in this material are marks and or registered marks.Unauthorized use is strictly prohibited. asimplex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4090-0002-9 11/2013 www.simplex-fire.com C 2013 7.Vco Eire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. B®Simplex System Accessories UL, CSFM Listed; Fire Alarm Control Relays, Track Mount and MEA (NYC) Acceptance* Encapsulated; Model 4098-9843 and 2088 Series Features UL listed under Standard 864 as Control Unit Accessory(UOXX) (366666 000000'000000 000000 CO N O R NCOC NCON " Track mount package availability: m1111111 m • Single relay module or four relay module with or •'® °� ° °� °'� without cover,with SPDT or DPDT contacts coo()o o" (3 0 0 0 6666 " 6 0 0 • LED indicates relay module status • Cover provide status LED viewing ports • Multiple coil voltage inputs,diode polarized for DC 2088-9020, MR204/C, Four DPDT Relay Package • Modules are track mounted with snap-apart feature with Enclosure(shown with cover removed) design allowing the four relay module to be separated Single encapsulated SPDT relay package with color coded 18 AWG wire leads,available in two versions: • 2088-9021 (PAM-1)Provides diode polarized multiple input voltage ability and LED indication • 4098-9843(PAM-SD)Provides a diode polarized 24 VDC coil with in/out wiring i APSC-PAM SD Descri•tion RIS TEL REO ORS These multi-purpose control relays offer SPDT or DPDT, 10 A(or 7 A)contacts in a variety of mechanical packages.Models are available for coil operation by one Encapsulated Relay Package of four input voltages allowing a single relay to be (typical of 2088-9021, PAM-1 and 4098-9843, PAM-SD) energized from a voltage source of 18-35 VDC or VAC, Specifications Continued 120 VAC,or 230 VAC(not available with 4098-9843). Voltage selection is made by wiring to the appropriate Encapsulated Relays,see page 2 for dimensions input terminals or wire leads. 18 AWG(0.82 mm2)color-coded Connections wire leads Each relay model(except model 4098-9843)contains a red LED which indicates that the relay is energized. Relay 2088-9021 Mounting options are varied for application flexibility. Contact Ratings 10 A @ 120 VAC, resistive Track mounted relays may be"snapped apart"from a Voltage 18-35 VAC/VDC, 120,or 240 VAC standard four-module assemblyand used independently if Coil p y Ratin s 15 mA @ 24 VACNDC, desired. 9 Current &@ 120 or 230 VAC S•ecifications Relay 4098-9843 Coil Ratings 18-32 VDC input, polarized, 15 mA Track Mount Relays,see page 2 for dimensions @ 24 VDC Coil Voltage 18-35 VACNDC, 120,or 230 VAC 7 A at 0.35 p.f @ 28 VDC& SPDT models=18 mA Contact Ratings 120 VAC Coil Current DPDT models=40 mA 250 pA @ 5 VDC Terminal Blocks Up to 14 AWG(2.08 mm2) Temperature Ratings 10 A @ 120 VAC UL Listed Range 32°F to 120°F(0°C to 49°C) Contact Ratings N.O. rated 1/6 HP,N.C.rated 1/8 HP Operating Range -58°F to 185°F(-50°C to 85°C) 7A @ 28 VDC and @ 230 VAC Humidity 85%RH Non-condensing Temperature Ratings UL Listed Range 32°F to 120°F(0°C to 49°C) *Listings are under Apollo America Inc.per model numbers Operating Range -58° F to 185°F(-50°C to 85°C) shown on page 2.See CSFM Listing 7300-1004:0101 for allowable values and/or conditions concerning material Humidity 85%RH Non-condensing presented in this document. S2088-0010-9 10/2013 Rela Selection Chart Module Reference Model Relay Packaging Dimensions Positions Number Number Type 2088-9007 MR-101/T SPDT 3-1/4" H x 2-1/8"W x 1-1/2" D Track mount,without cover ( 2088-9009 MR-201/T DPDT 83 mm x 54 mm x 38 mm) One 2088-9008 MR-101/C SPDT Track mount with cover 5-1/8" H x 3-1/8"W x 2-1/2" D 2088-9010 MR-201/C DPDT (131 mm x 79 mm x 64 mm) 2088-9017 MR-104/T SPDT 3-1/4" H x 8-1/2"W x 1-1/2" D _ Track mount,without cover 2088-9019 MR-204/T DPDT (83 mm x 216 mm x 38 mm) Four 2088-9018 MR-104/C SPDT 5-1/8" H x 9-1/2"W x 2-1/2" D Track mount with cover - 2088-9020 MR-204/C DPDT (131 mm x 241 mm x 64 mm) Encapsulated, multi-voltage coil, 1-1/2" H x 1"W x 7/8" D 2088-9021 PAM-1 color coded 18 AWG(0.82 mm2)wire (38 mm x 25.4 mm x 22 mm) leads,with coil status LED NA SPDT Encapsulated, 24 VDC coil, color coded 1-1/2" H x 1-3/16"W x 13/16" D 4098-9843 PAM-SD 18 AWG (0.82 mm2)wire leads(no LED) (38 mm x 30 mm x 21 mm) Track Mount Rela Wirin• Reference SPDT contacts rated DPDT contacts rated 10 A @ 120 VAC, resistive /10 A @ 120 VAC, resistive ® NC C NO NC C NO NC C NO ® ® ®1 tt ® ® ® ® ® Relay LED energized di - ® ® ® ® ® ® ® ® 0 0 18/24 115 230 0 0 0 18/24 115 230 - (18-35)VDC (-) (+) (18-35)VDC (-) (+) Coil voltage Coil voltage (note polarity (18-35)VAC AC AC (note polarity (18-35)VAC AC AC for DC) 120 VAC N V for DC) 120 VAC N V 230 VAC V V 230 VAC V V Terminal strip connections Terminal strip connections SPDT models DPDT models T}''('0,SIMPLEX,and the product names listed in this material are marks and or registered marks.Unauthorized use is strictly prohihited. B®S i m p I Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S2088-0010-9 10/2013 www.simplexgrinnell.corn r 2013 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. ®Simplex TrueA/ert® Notification Appliances UL Listed; FM, CSFM, and Non-Addressable AudibleNisible Notification MEA (NYC) Approved* Appliances for 4-Wire Operation (Horn/Strobe) Features Wall mount audible/visible notification appliances with efficient piezoelectric horn and high output xenon strobe for 4-wire control applications Xenon strobe visible notification appliance: • 24 VDC operation with switch selection for free-run or synchronized flash rate • Models available with 15,75,or 110 candela • UL listed to Standard 1971 • Compatible with ADA requirements(refer to important installation information on page 4) • Strobe candela rating is clearly indicated on reflector Electronic horn audible notification appliance: simplex • Low current operation(25 mA @ 24 VDC) _ • Harmonically rich output sound suitable for either coded or steady operation • UL listed to Standard 464V � Available housing colors: • Red cover with white"FIRE"lettering • White cover with red"FIRE"lettering FIRE Flexible, easy, and convenient semi-flush or surface wall mounting: TrueAlert Non-Addressable AN Notification Appliances • Easily mounts to single gang,double gang,or 4-inch are available in Red with White Lettering and White with square outlet box Red Lettering • Optional mounting adapters are available to cover surface mounted electrical boxes and to adapt to Descri•tion Simplex®2975-9145 boxes TrueAlert non-addressable audible and visible • Diode polarized inputs for connection to reverse notification.For applications requiring audible/visible polarity,supervised notification appliance circuit(NAC) (AN)notification with horn tones,these Simplex 4903 • In/out wiring terminals for 18 AWG to 12 AWG, series appliances combine a high intensity strobe with a accessible from front of housing,providing easy access low current electronic horn in a compact package that is for installation,inspection and testing easy and quick to install.Each appliance can be controlled • Rear of housing assembly does not extend into box independently from each other using conventional reverse • Rugged,high impact,flame retardant thermoplastic polarity NACs. housing with optional covers available to convert Multiple models with flexible mounting choices. housing color These 4-wire operation AN appliances are available with • Optional UL listed red wire guard is available for semi- three strobe intensity levels(15,75,or 110 cd)and with flush or surface mounting red or off-white housings.Mounting can be semi-flush or surface mount on a standard single or double gang,or 4" square(102 mm)electrical box.Optional accessories are • This product has been approved by the California State Fire Marshal(CSFM)pursuant to available to increase mounting and application flexibility. Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7125-0026:239 for allowable values and/or conditions concerning material presented in this Strobe Selection document.It is subject to re-examination,revision,and possible cancellation.Accepted for use—City of New York Department of Buildings—MEA35-93E.This product was not ULC Proper selection of visible notification is dependent on listed as of document revision date.Additional listings may be applicable;contact your local proper occupancy,location,local codes,and applications Simplex product supplier for the latest status.Listings and approvals under Simplex Time p p Recorder Co.are the property of Tyco Safety Products Westminster. of: the National Fire Alarm Code (NFPA 72);ANSI A117.1;the appropriate model building code,BOCA, ICBO,or SBCCI,and the application guidelines of the Americans with Disabilities Act(ADA). S4903-0011-5 9/2004 Strobe O•eration Horn O•eration TrueAlert non-addressable AN strobes can be set TrueAlert non-addressable A/V horns provide an for free-run operation or synchronized operation using an audible notification output that is a loud and penetrating, on-board selection switch.When selected for harmonically rich sound capable of a continuous or coded synchronized operation,flash operation is controlled output per the controlling NAC's capabilities. from: • Synchronized Flash Modules,4905-9914(Class B) or 4905-9922(Class A) • 4006,4008,4100U,and 4010 Fire Alarm Control Panels(refer to individual product data sheets for • details) • 4009 IDNetTM NAC Extender,models 4009-9201 and 4009-9301 (refer to data sheet S4009-0002) Product Selection AudibleNisible Notification Appliances(Horn/Strobe) Model Number Visible Notification Appliance Output Housing Color 15 cd 75 cd 110 cd 4903-9425 ✓ 4903 9426 Red with white "FIRE"lettering 4903-9427 1 4903-9431 ✓ 4903-9432 White with red "FIRE"lettering 4903-9433 ✓ Adapters Model Description Dimensions 4905-9937 Surface mount red adapter skirt Use to cover 1-1/2" 5-3/8"H x 5-1/4"W x 1-5/8"D deep surface (136 mm x 133 mm x 41 mm) 4905-9940 Surface mount white adapter skirt mounted boxes Total depth with strobe=4-3/8"(111 mm) 4905-9931 Red adapter plate,for mounting to Simplex 2975-9145 box 8-5/16"x 5-3/4"x 0.060"Thick (typically for retrofit,may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red mounting box, requires 4905-9931 adapter plate 7-7/8"x 5-1/8"x 2-3/4"Deep (130 mm x 200 mm x 70 mm) Synchronized Flash Control Modules Model Description Dimensions 4905-9914 Synchronized Flash Module, Epoxy encapsulated with Class B(Style Y)operation _ in/out 18 AWG wire 1-3/8"W x 2-7/16"L x 13/16" H 4905-9922 Synchronized Flash Module, leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) Class A(Style Z)operation requires 10 mA for power Optional Covers and Guard Model Description Dimensions 4905-9994 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D 4905-9995 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) 4905-9961* Wire guard with mounting plate,red,compatible with surface 6-1/16"H x 6-1/16"W x 3-1/8"D or semi-flush mounted boxes (154 mm x 154 mm x 79 mm) "UL listed by Space Age Electronics Inc. 2 S4903-0011-5 9/2004 S•ecifications General Specifications Housing Dimensions(including lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Temperature Range 32°to 122° F(0°to 50° C) Humidity Range 10%to 93%, non-condensing at 100° F(38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Strobe Specifications Rated Voltage Range UL Listed Range Regulated 24 VDC;see Note 1 below ULC Listed Range 20 VDC to 30 VDC per ULC S526-M87 Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC Maximum RMS Current Rating per Strobe Output 15 cd 75 cd 110 cd (see Note 2 below) 76 mA 192 mA 227 mA Reference Currents 18 VDC 68 mA 171 mA 202 mA at other voltages 24 VDC 51 mA 128 mA 151 mA Horn Specifications UL Listed Range 16 VDC to 33 VDC,see Notes 3 and 4 below Rated Voltage Range ULC Listed Range 20 VDC to 30 VDC per ULC S526-M878 Sound Output Characteristics 2400 to 3700 Hz sweep,modulated at 120 Hz rate Voltage 16 VDC 24 VDC 33 VDC Sound Type(see Note 5) Steady Coded Steady Coded Steady Coded Sound Output and Current 15 mA 10 mA 25 mA 15 mA 28 mA 20 mA Current Ratings @ 10 ft(3 m) Reverberant Chamber, 85 dBA 82 dBA 88 dBA 84 dBA 91 dBA 87 dBA UL 464 Test Anechoic Chamber 90 dBA 86 dBA 91 dBA 86 dBA 91 dBA 87 dBA NOTES: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired,changes effective May 1,2004.This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions.The strobe of this AN is field selectable for free-run or synchronized operation. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) 3. Terminals are provided for wiring the horn and strobe of these A/Vs to separate NACs. Operation of the horn and strobe is not separately controlled when they are both wired to the same NAC. 4. The rated voltage range listed is the absolute operating range.Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the notification appliance circuit under worst case conditions. 5. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a"fast"setting. Under the same test conditions,coded horn output"peak"sound level readings are typically 4 dBA higher. 3 S4903-0011-5 9/2004 Installation Reference, Surface or Semi-Flush Mounting Mounting is compatible with /LTh c � Th Th single gang,double gang,and fr 0 0 4"(102 mm)square boxes, o 1-1/2"(38 mm)deep,by others r, 1 1 IMPORTANT!WALL MOUNT e.__ o — pit //or —n37 INSTALLATION HEIGHT REFERENCE [1 _l ! Horn wiring \ ) Bottom of lens terminals I is either even - 1, 1 � .` y J with,or slightly Electrical © 1L. O i above bottom box outline Strobe mode eic,,,..;11._ ___,© © f • ^ of compatible selection switchE `' r boxes Wiring access hole =gg,�IE i Il �9-I 4 j j 00+ 1 • o 0 Strobe wiring terminalsNFPA 72 requires 80"(2.03 m) r ' ` � Mounting Holes: that the entire lens minimum L / = n 4"square(4) be not less than "'°°'wear• ® - U Single gang(2) 80"and not greater G' W Double gang(3) than 96"above the finished floor Transparent housing and lens assembly Removable cover (tool required) F I______131______E Installation Reference, Ada'ter Plate, Guard, and Ada ster Skirt Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard M_7 Surface mount conduit and O box shown for reference I 4"(102 mm)square MIr ____ (���1____ t ""'� ..� I box profile,1-1/2" I,FI' ' ` II (38 mm)deep F I��11�= = 1111, IN IlMI I���-��I�����1�I Q O I 4905-99611 II' NMI410W111 IOW II! 'WW1 Wire Guard A/V lig! F0QE Wiii �_ __t, 4905-9931 Adapter PlateOptional Surface Mount Adapter Skirt, -=Ir O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco,Simplex,the Simplex logo,IDNet,and TrueAlert are trademarks of Tyco International Services AG or its affiliates in the U.S.and/or other countries.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). f3 Simplex Tyco Safety Products Westminster•Westminster, MA•01441-0001•USA S4903-0011-5 9/2004 ® www.tycosafetyproducts-usa-wm.com ©2004 Tyco Safety Products Westminster.All rights reserved All specifications and other information shown were current as.of document revision date and are subject to change without notice. ANSUL SAPPHIRE CLEAN-AGENT FIRE SUPPRESSION SYSTEMS 2,1. it f;`Ms °.e`."�&fiokimaP`odf Data/Specifications FEATURES • • UL/ULC Listed • FM Approved tet P. • Effective total flooding for Class A, B,and C fires • Clean agent suitable for protection of high-value assets .. • Long-term,sustainable alternative to halon,HFCs,and PFCs 1 APPLICATION . ..<.. ► The ANSUL SAPPHIRE Clean-Agent Fire Suppression System 11=3 3 ► utilizes 3M NoveCTM 1230 Fire Protection Fluid as the suppression agent.Novec 1230 fluid can effectively be applied in total flooding fire suppression applications in the following areas: • Data Processing Centers • Tape Storage • Vaults • All normally occupied or unoccupied electronic areas where equip- _. ment is either very sensitive or irreplaceable • Telecommunications including Cellular Sites and Switching Centers • Military Systems including Combat Vehicles and Marine Engine itr Rooms• Transportation including Merchant Marine Vessels and Mass Transit Vehicles • Recreation including Pleasure Craft and Race Cars sa - ENVIRONMENTAL IMPACT ► The SAPPHIRE Suppression System utilizes Novec 1230 fluid.This fluid has 0.0 ozone depletion potential,an atmospheric lifetime of just 006464 five days,and a global warming potential of 1.0. Novec 1230 fluid is registered with the U.S.EPA under TSCA and European ELINCS. It has met the requirements of registration under SNAP(Significant New Alternatives Policy)and is approved for use as an alternative to Halon Exposure to Novec 1230 fluid at design concentrations up to 10% 1301 for total flooding applications in occupied spaces. ► (NOAEL)is not hazardous to health. Refer to NFPA 2001 for expo- s' sure requirements.As with Halons,the EPA and the National Fire Protection Association recommend that unnecessary exposure to any agent be avoided and that personnel evacuate protected areas as DESCRIPTION quickly as possible to avoid the decomposition products of the fire. A system installation and maintenance manual is available containing The SAPPHIRE Suppression System is an automatic,fixed nozzle,fire information on system components and procedures concerning design, ► suppression system using Novec 1230 fluid for Class A,B,and C fires. operation,inspection,maintenance,and recharge. The system is designed and installed in accordance with the National The system is installed and serviced by authorized distributors that are Fire Protection Association(NFPA)Standard 2001,"Clean Agent Fire trained by the manufacturer. Extinguishing Systems."It is listed by Underwriters Laboratories, Inc. ► Basic Use—The SAPPHIRE Suppression System is particularly useful (UL), Underwriters of Canada(ULC),and approved by Factory Mutual for suppressing fires in hazards where an electrically non-conductive (FM). medium is essential or desirable,where clean up of other agents pres- The system is capable of automatic detection and actuation and/or ► ents a problem,or where the hazard is normally occupied and requires remote manual actuation. a non-toxic agent. The detection portion of the fire suppression system allows for auto- Composition and Material—The basic system consists of extin- ► matic detection by means of the AUTOPULSE Detection and Control guishing agent stored in steel containers.Various types of actuators, System.Several different detection options are available such as pneumatic and electric,are available for release of agent into the • smoke or air sampling. hazard area.The agent is distributed and discharged into the hazard area through a network of pipe and nozzles.Each nozzle is drilled with a fixed number of orifices designed to deliver a uniform discharge to the protected area. On large hazards,where two or more tanks are required,actuation design can be utilized to actuate multiple tanks. DESCRIPTION (Continued) TECHNICAL DATA ►Additional Equipment Includes—AUTOPULSE detection and control ► Applicable Standards—The SAPPHIRE Suppression System panels,releasing devices and alarms,strobes and warning signs.All complies with the NFPA Standard 2001,"Standard for Clean Agent or some are required when designing a total system. Fire Extinguishing Systems,"and EPA Program SNAP(Significant 3M Novec 1230 Fire Protection Fluid—Novec 1230 fluid,referenced New Alternate Policy). as FK-5-1-12 in NFPA 2001 and ISO 14250,is a fluorinated ketone(or ►The system is listed by Underwriters Laboratories, Inc.(UL), fluoroketone)with a chemical structure of CF3CF2C(0)CF(CF3)2. It is Underwriters Laboratories of Canada(ULC),and approved by Factory ►a clear,colorless,odorless liquid that is super-pressurized with nitro- Mutual(FM). gen and stored in high-pressure tanks as part of the total SAPPHIRE P.Suppression System.Although stored in liquid form,Novec 1230 fluid will turn to a gas upon discharge,making it an effective total flooding agent for a variety of hazards.As a clean agent,it leaves no residue INSTALLATIONS ►behind and will not affect sensitive high-value electronics. Refer to 3M Novec 1230 Fire Protection Fluid Data Sheet(Form No. F-2003127) All system components and accessories must be installed by person- for more detailed information. nel trained by the manufacturer.All installations must be performed Tank Assembly—The agent storage tanks are manufactured in according to the guidelines stated in the manufacturer's design, instal- accordance with DOT4BW450 and consist of a tank fitted with a valve lation,operation,inspection, recharge,and maintenance manual. and internal siphon tube.Tanks are available in eight sizes.Agent quantities are available in 1 lb fill increments.A nameplate is adhered to the tank displaying the agent weight and gross weight. Electric Actuator—The 24 VDC electric actuator is required to elec- AVAILABILITY AND COST trically actuate the tank valve.An electric signal is received from the AUTOPULSE Control Panel which operates the solenoid in the actua- ►Availability—SAPPHIRE Suppression Systems are sold and serviced tor.This causes the actuator to open the tank valve and discharge the through a network of independent distributors located in most states agent.On multiple tank systems,only one electric actuator is required ►and many countries. on the master tank valve.The remaining tanks will be actuated pneu- matically through 1/4 in.stainless steel hose installed between each Cost—Cost varies with type of system specified, size,and design. pilot pressure port. Pneumatic Actuator—The pneumatic actuator is required to pneu- matically actuate the agent tanks.The actuator operates from the pressure from the nitrogen cartridge located in the ANSUL AUTOMAN TECHNICAL SERVICES II-C release.When the pneumatic actuator is pressurized,the internal ► actuator piston pushes down on the valve stem,opening the tank For information on the proper design and installation,contact a local ► valve,and allows the agent to discharge. ►authorized SAPPHIRE Suppression System distributor.The applica- tions engineering department is also available to answer design and Installation questions. ► detection and control system is designed to monitor fixed fire hazards. The control system can automatically actuate the fire suppression ► system after receiving an input signal from one or more initiating devices,such as a manual pull station or detector.The control system incorporates an internal power supply,in-line emergency batteries,and solid state electronics. ANSUL AUTOMAN II-C Releasing Device—The ANSUL AUTOMAN II-C releasing device consists of a metal enclosure which contains a spring-loaded puncture pin release mechanism,an actuation cartridge, ► electrical circuitry,and an input/output terminal strip for making electri- cal connections.The ANSUL AUTOMAN II-C releasing device provides ► automatic pneumatic actuation of the SAPPHIRE Suppression System. ► When wired to an AUTOPULSE control system,it provides supervised electric detection and release. It also provides manual actuation using the strike button on the release enclosure. Nozzles—Six sizes of discharge nozzles are available.Nozzles are designed to discharge agent in a 360°or 180°pattern. Nozzle sizes ► and orifice sizes are determined by the Hydraulic Flow Calculation Program. ► Hydraulic Flow Calculation Program—SAPPHIRE Suppression ► Systems are based on a Hydraulic Flow Calculation Program.The program predicts the two-phase flow of Novec 1230 agent and nitro- gen through a pipe network. Information detailing the enclosure is entered and the program calculates the required pipe sizes,nozzle drill sizes,average nozzle pressures,and discharge times.As system design calculations are critical to the success of the suppression ► system,only factory-trained personnel are authorized to perform system calculations. ► Indicates revised information. 3M NOVEC is a trademark of 3M Company,St.Paul,Minnesota. two www.ansul.com Fire Suppression One Stanton Street &Building Products Marinette,WI 54143-2542 Copyright©2 9 2 Form No..F-22 003239-2