Loading...
Report (2) tz,cis Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE . . „— The TYCO Series TY-FRB Sprinklers Description described herein must be installed and - maintained in compliance with this doc- - The TYCO Series TY-FRB,5.6 K-factor, ument,as well as with the applicable Upright(TY313)and Pendent(TY323) standards of the National Fire Protec- ) Sprinklers described in this data sheet tion Association,in addition to the stan- `Is' ' are quick response,standard coverage, dards of any other authorities having ' 1 decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair `' i, A sprinklers designed for use in light or the performance of these devices. __== - -, ordinary hazard,commercial occupan- - — cies such as banks, hotels, and shop- The owner is responsible for maintain- .-- ping malls. ing their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble,is intended for use in areas with a any questions. 4` finished ceiling.This recessed pendent sprinkler uses one of the following: I • A two-piece Style 15 Recessed Sprinkler .c. : Escutcheon with recessed adjust- > ' `" * ;, Identification f ment up to 5/8 inch (15,9 mm)from �, .� �;�� the flush pendent position. e,, Number (SIN) -� • A two-piece Style 20 Recessedf Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT / ment up to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K, 1/2"NPT 1 x °- the flush pendent position. ' ' The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Intermediate level versions of Series Approvals 175°F(79°C) UL and C-UL Listed 200°F(93°C) TY-FRB Sprinklers are described in 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM,LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler:Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)` Button Brass/Copper `The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psilf2(80,6 LPM/barlI2) Deflector Bronze with respect to handling and instal- • lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page2of4 Components: * 1 Frame 4 Bulb Temperature rating is Pipe thread connections per ISO 7-1 indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED I Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* .....lic` „\ 7/16" r ` I t �_' :`dTl �., iii r--���t�� I \-- T 5 t ;1■fc (11,1 mm) 4 I NOMINAL 2" i� i1 MAKE-IN (50,8 mm) 2 ItV E p' iii �' 2" 1-3/8" - 3 / W t (50,8 mm) I (34,9 mm) I / ikr4 f I WRENCH 1 1 / FLATS } , 1 1/2"NPT** DEFLECTOR* — 2-7/8' (73,0 mm)DIA. -- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE e, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A°) fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally, a small air bub- WRENCH Criteria ble should be present. The diameter of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313) and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) �,yr Sprinklers are intended for fire protec- temperature ratings. si tion systems designed in accordance At with the standard installation rules rec- ognized by the applicable Listing or Y PP Y 9 Approval agency(such as, UL Listing imum to maximum torque of 7 to 14 `� is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels %re 13, and FM Approval is based on the of torque can distort the sprinkler Inlet PUSH WRENCH requirements of FM's Loss Prevention with consequent leakage or impairment Data Sheets).Only the Style 15 or Style of the sprinkler. IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent1 installations. insufficient adjustment in the Escutch - WITH SPRINKLER WRENCHING AREA eon Plate by under-or over-tightening the sprinkler. Re-adjust the position of FIGURE 3 the sprinkler fitting to suit. W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- - dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the - pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3.Tighten the sprinkler into the 2-7/8"DIA. - sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4"DIA. Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) J Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers \ - FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" 1` "L _ Sprinklers must be installed in accor- (9,5±7,9 mm) % 'r dance with the following instructions. t / �, Step A.After installing the Style 15 or Mir 1/8" I MOUNTING . Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread — sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8°(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4"(19,1 mm) sprinkler fitting. Step B.Tighten the sprinkler into the FIGURE 4 Step B. fittinggusing onln the W-Tthe SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) 7spriRecessed Sprinkler Wrench (Figure WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 2-1/4"DIA. ishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16±1/4' 1/2" 12 kler and push the Closure over the (7,9±6,4 mm) ( 7 mm) Mounting Plate until its flange comes in + mi FLUSH contact with the ceiling. / _1 , 7 in t Care and fMOUNTING/ rl, Maintenance SURFACE (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, I Upright(TY313)and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hay- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ slippage,or the like,must be replaced. cleaned by means of gently dusting with a feather duster; otherwise,non- Also, replace any sprinkler that has a - operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref.Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX i I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 . NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2"NPT) TY313 3 PURE WHITE(RAL9010)* POLYESTER 155 155-F(68°C) 371 5.6K PENDENT(1/2"NPT) TY323 q SIGNAL WHITE(RAL9003) POLYESTER 175 175°F(79°C) .Use suffix 1"for ISO 7-1 connection; 9 CHROME PLATED 200 200`F(93°C) for example,77-370-4-175-I Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6,Quick Response,(specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish,P/N(specify*) Specify: Style 20 Recessed Escutch- eon with(specify*)finish,P/N(specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright®2014 Tyco Fire Products,LP. All rights reserved. tyco TEFLON is trademark of The DuPont Corporation. Fire Protection Products Dyna-Thread® - M-COAT® Submittal Data Sheet O Full Line Sch-40 Replacement Dyna-Thread—M-COAT Specifications Dyna-Thread"'—M-Coat`"sprinkler pipe represents an engineering NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR advancement for the sprinkler pipe industry.It combines the safety In;mm In;mm Lbs/Ft kg/m Lbs/Ft;kg/m Unthreaded Threaded and longevity of traditional Sch-40 pipe with quality and superior 1" 1.080 1.330 1.75 11.39 1.00 hydraulic advantages. 25 27.4 2.0 2.60 — — 11/2" 1.408 1.870 2.54 9.50 1.00 ® Comparison to Schedule 40 32 35.8 2.8 , 3.78 — — 11/2" 1.639 2.290 3.22 9.14 1.00 Dyna-Thread'—M-Coate inside diameter is up to 3.6% larger than Sch-40 40 41.6 3.4 4.79 — — giving it superior hydraulics.Also,when used in combination with Dyna- 2" 2.104 3.050 4.57 8.41 1.00 Flow—M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 — — approved UL, ULC,and FM for fire sprinkler applications.The life expectancy of Dyna-Thread—M-Coat and Sch-40 are equal based on the calculated wall 0 0 thicknesses per UL.The consistent quality of steel used to make Dyna-Thread— APPROVED M-Coat facilitates smooth threading and lower maintenance costs.The exterior of Dyne-Thread—M-Coat is protected by a clean,durable mill coating for O American Made extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available and lighter weight, Dyna-Thread—M-Coat reduces installation fatigue and through distributors in the USA, Canada, Mexico,and is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR)is a UL Latin America. (Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed 0 Specifications & Approvals thread,assumed to be the weakest point of the pipe length.Dyna-Thread— Ui-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread—M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with f 1FPA-13.All sizes of Dyna-Thread—M-Coat are rated at 300 psi working O Comparison to L.W.T. Pipe pressure.Dyna-Thread—M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread—M-Coat dry and pre action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints.Dyne-Thread— use in wet systems. Dyna Thread—M-Coat is approved lot all M-Coat is approved for standard hanger spacing(15 ft.0.C.),can be used as threaded couplings and welded outlets and is suitable for all earthquake sway bracing,and is safe to use as drops.Dyna-Thread—M-Coat roll grooved,and plain end fittings.(See listing information). is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread—M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: 91'allied Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com 16100 5 Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUIT' Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 °""'°` re ©2013 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1301 S ,ar3 � 'f �,1. 4.0c 'n a•44, ys h,. • • r � ->xc� ��` � : "Yi r- r ryx tis � I qi` R 1 .. 'I` I O :N„ A . � , ri r"-:' i.F';.'�"w �'S Ydr-{5 �,W+. r,.�. ..q�..r.;, w..:. `,3'T' .=4'.? ,�y37 VyyR+ o$1.5#, `*"ti$^ Ductile Iron Threaded Fittings S i e ►;ions • < branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP c ®L us • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 11/14* • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 3�I , , Ductile Iron Fittings - Class 300 UL/FM LQuurTY MS' . • c0US APPROVED Fig. 35E 3-90°Elbow LISTED AIt. Size A Packing Weight �� in PartNumber in Inner Master lb ei. 1/2 35E 3004 1.13 100 200 0.2 ��� 3/4 35E3006 1.31 70 140 0.31 j A 1 35E 3010 1.50 40 80 0.5 /! 0 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow B Size A B PackingWeight 4-- Part Number g in in in Inner Master lb ..'•.� 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 .......% 3/4 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 �.• 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 , _ �. % % 1-1/4 x 1/2 35RE3012004 134 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36, 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 D 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 U 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 C 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 I I Fig. 35F 3-45°Elbow Part Number E Size A Packing Weight I� A in in Inner Master lb 1/2 35F 3004 0.88 150 300 0.2 #0.44t 3/4 35F 3006 0.98 80 160 0.3 �� 1 35F 3010 1.13 40 80 0.5 �i .0 1-1/4 35F 3012 1.29 25 50 0.7 st � IA 1-1/2 35F 3014 1.44 20 40 1.0 ,i-i /. 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3-Tee Size Part Number A Packing Weight in in Inner Master lb "�` �1. `` A 1/2 35T 3004 1.13 80 160 0.3 III 3/4 35T 3006 1.31 30 60 0.5 1 351 3010 1.50 25 50 0.7 ilb ���� �� 1-1/4 35T 3012 1.75 10 20 1.1 A A 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • ww•w•smithcooper.com Pipe Hangers Fig.200- "Trimline"Adjustable Band Hanger (B-Line Fig.B3170NF) ®TOLCO Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) cCus " Fig.200C- "Trimline"Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) USTED Fig.200S - "Trimline"Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications i ,. Function: For fire sprinkler and other general piping purposes. Knurled --/ (,> swivel nut design permits hanger adjustment after installation. 41 Features: ,-� -=_ • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe _ �.''. l types and protect CPVC plastic pipe from abrasion.Captured design `"� keeps adjusting nut from separating with hanger. Hanger is easily B installed around pipe. - = A ,i For hanger with non-captured nut order Fig. 200S. ;, • (21/2" (65mm)thru 8" (2oomm))Spring tension on nut holds it securely in �_ hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (2oomm)) Fig.200-1/2.200-3/4 in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM)(3/4" (20mm)thru 8" (20omm)). Fig.200-1 to 200-2 Fig.200-23/4 to 200-8 Conforms to Federal Specifications W\N-H-1 71 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, " Type 10. Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel £, r materials will be supplied with (2)hex nutsiii. in place of a knurl nut. Order By: Figure number and pipe size ( Y a Designed to meet or exceed requirements of FM DS 2-0. Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) t 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 't 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) '' 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) f , 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) / 200-11/2 11/2" (40) 3/8"-16 31/6 (98.4) 27/8" (73.0) 14 (6.4) 1 /' . 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 41. 200-21/2 21/2" (65) 3/8"-16 55/8° (142.9) 41/s" (104.7) 27 (12.3) o --:'' 200-3 3" (75) 3/e-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S - 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/e'-16 73/8" (187.3) 5" (121.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2•-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions B-Line 21 by E:T•N VERTICAL MOUNT SAMMYS SAMMYS® for Wood itNot less than Wood Flooring 7 nominal width Product Features 4(11/2)� •No pre-drilling required. IoNot less than •Quick to install using the Sammy 3'nominal '. Nut Driver with an 18V cordless thickness(2.1/7) (depth or side Wood Joist drill/driver. f Not member) i_ ` . - � " •Saves time from traditional Double Sheetnock methods. Fo•ve cal ase- ceiling moral)in centor of loser taco. •Reduces installation cost. f,Tm mu-2`crbormentrlo base ma nal tar NFOA 13 comps arce. Composite 1 Truss Coisalt tress manufacturer for •Made in the U.S.A. - reccmmercec rah llatun pa 9f I I'll • 'Pre-dyeing ma/oe repred tot CST 25- U Taal aaaeab'e on page 10_ i 1 Rod Part Screw Ultimate UL Test FM Test Box Case Approvals Size Number Model Descriptions Pullout(lbs) Load(lbs) Load(lbs) Qty Qty 114" 8002957 GST 100 1/4 x 1" 210(7116'058) 25 125 670(314'Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1(4" 8004957 GST 300 1/4 x 3" 2060(Fir) 25 125 318' 8006957 GST.75 114 x 3/4" 564 (3/4"Ply) 25 125 JD" 3(8" 8007957 GST 10 1/4x1 ' 210(7/16"OSB) 300 25 125 670(314'Ply) — A Q 3/8" 8008957 GST 20 114 x 2" 1760(Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 1/4x2" 1760(Fir) 850 25 125 Q" 3/8' 8009925 GST 25.3.80 318 x 2-1/2' 2113 (Fir) 1500 25 125 #14 Black Q-11> 3/8' 8010957 GST 30 1/4 x 3" 2060(Fir) 1500 1475 25 125 Nut Driver 3/8" 8069925 GST 30-SS 114 x 3' 2060 (Fir) 25 125 Part#8113910 3/8' 8011925 GST40 1/4x4' 2180(Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 112" 8013925 GST 2 114x2" 1760(Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2' 2113 (Fir) 25 125 1/2' 8015925 GST 3 114 x 3' 2275(Fir) 25 125 1/2" 8016925 GST 4 1/4x 4" 2180(Fir) 25 125 1/2' 8017925 GST 6 114 x 6" 2230(Fir) 25 125 #14 SW Red Nut Driver Part#8114910 SAMMY Swivel Hear° for Wood Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. •Accommodates up to 3'/z'x 12 pitch roof. •Reduces installation cost. •Allows 17°deflection from vertical. •Made in the U.S.A. Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Box Case • 4 I Size Number Descriptions Pullout(lbs) Load(lbs) Load(lbs) Thickness Qty Qty j 0-G 3/8' 8139957 SH-0S1 20 1/4x? 1257(Fir) 1050 1475 25 125 125 II 11'4 3/8' 8141957 SH-GST 30 1/4 x 3' 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the Face of the driver comes into Part#8113910 contact with the material you are installing into,continue driing until nut driver spins free.Instalation is then complete.Warranty requires the the museecof the appropriate nut driver for instalations. C t�/7 Q -y H For ost up to date infenraticnv , �sit'�rv,v.sammgsupersw cre .colll 4 \�j s Threaded Accessories B3205 -Threaded Rod (right-hand threads- both ends) (TOLCo Fig.103) �> B3205L -Threaded Rod (right&left hand threads) / TL Size Range: 3/8"-16 thru 3"-4 rod speciry length ��1l��lllh� Material: Steel ------< Function: Recommended for use as a hanger support in hanger assemblies. TL ��1 9length shown.Also l� available with left and right hand threads-specify Fig.B3205L when ordering. ��e Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number,rod size,length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) F 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B ' ` f% 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) ��/; L'�/sx'L'' s 5/e"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-314 C'1` 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 03205-118 z'.L'r 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) 'B3205-1 x'L', `'` 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) -11Iax'L' ;' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4x,'1' ` 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-1314x"L' ,: 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) 83.205-2 x'..` 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B 21/4 X'L' ; 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 83205-21/2 x'1' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205,23/4 x'L` +` 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) 03,P15,341-14-:::- 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig.99-All Threaded Rod Cut To Length -;-o• Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length �Ai,yol ``��' Material: Steel ����� y -o.0) Maximum Temperature: 750°F(399°C) 001 v`o Finish: Plain.Contact B-Line for alternative finishes and materials. 0 d Order By: Part number,rod diameter and finish a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) " ,i; TR,tI4" '120. re 99 1/41 l8 20 240 (1.07) 12 (5.44) #AIRI"..x 120 99-318"x a 16 730 (3.24) 29 (13.15) B 12"C 1'20 99-�112"x - 13 1350 (6.00) 53 (24.04) 1 i. !" 1'120 .!..99-1.#%-31a, 99-5/a" I 11 2160 (9.60) 89 (40.37) FAIR 3I4".a#20 ; j 99 3/s"x length j 10 3230 (14.37) 123 (55.79) '''-*,r,#:;-,07'.,:,0,41±1 '`91,77.07:X.length' 9 4480 (19.93) 170 (77.11) ',ATR 1"X 120 ', ; 99-1"z len I:' 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports 236 Revised 4:28/2014 B-Line by E:T•N