Loading...
Permit (143) �� CITY OF TIGARD MASTER PERMIT S COMMUNITY DEVELOPMENT Permit#: MST2015-00258 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 02/22/2016 Parcel: 1 S 136AA12300 Jurisdiction: TIGARD Site address: 10178 SW 67TH AVE Subdivision: OAK STREET ESTATES Lot: 18 Project: Oak Street Estates, Lot 18 Project Description: New SF BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 3 First: 1692 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 23 Bathrooms: 3 Second: 905 sf Garage: 417 sf Front: 20 Smoke Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Yes Total: 2597 sf Value: $314,174.54 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Tvoes Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2597 Owner: Contractor: LENNAR NORTHWEST INC LENNAR NORTHWEST INC Required Items and Reports(Conditions) 11870 NE 99TH ST,STE 1170 11807 NE 99TH STREET SUITE 1170 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98682 VANCOUVER,WA 98682 PHONE: PHONE: 360-216-6423 FAX: 360-258-7901 Total Fees: $23,611.94 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232..19887-oorr11,.88000.332.2344. - / Issued By: dfijPermittee Signature: r /_ '/r/ e'9�0w Call 603.639.4176 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Ls .2 .?///5— Residential RECEIVED FOR OFFICE USE ONLY 5 City of Tigard DEC 21 2015 Received �►�� Date/By: A2/.?a2/� •� / ermitN � �D �� 1 C n 13125 SW Hall Blvd.,Tigard,OR 972238. Plan Review/ a, ]JL. Other Peru �Afijr���� Phone: 503.718.2439 Fax: 503.598. 'OF TIGARD Date/By: ! J TIGARD Inspection Line: 503.639.4175 t !I , ^' Date Ready/By: Juris: H See Page 2 for Internet: www.tigard-or.gov B�� �+ ��+ DIVISION V Notified/Method:VI lam /3=1"7" Supplemental Information O)= tilS d- GG,i.n TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ®New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. 4 ® 1-and 2-family dwelling 0 Commercial/industrial Valuation:31t i er $ 1 e ❑Accessory building 0 Multi-family Number of bedrooms: 3 ❑Master builder 0 Other: Number of bathrooms: —.27,......:: JOB SITE INFORMATION AND LOCATION Total number of floors: 2. Job site address: /pi 76' _.5-14/ 6 '7� /g vg New dwelling area: 2, .5-q 7 square feet 3 0 }4- City/State/ZIP: T76'/9RD) U� 9 77 2 2 3 Garage/carport area: 4. / 7 square feet Suite/bldg./apt.no.: Project name: Covered porch area: j 64- square feet 9 i 5 Cross street/directions to job site: Deck area: square feet j C 9a. Other structure area: square feet Z.-;75 _ REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: �!�ir S�CCT G STA TLS Lot no.: f a Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. NSFR Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER 0 TENANT Number of stories: Name:LENNAR NW,Inc. Type of construction: Address:11807 NE 99th Street,Suite 1170 Occupancy groups: City/State/ZIP:Vancouver,WA 98682 Existing: Phone:(360)258-7900 Fax:(360)258-7901 New: E] APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES* Business name:Lennar NW,Inc. (Please refer tofee schedule) Structural plan review fee(or deposit): Contact name:Charles Webb Address:11807 NE 99th Street,Suite 1170 FLS plan review fee(if applicable): City/State/ZIP:Vancouver,WA 98672 Total fees due upon application: Phone:(360)258-7900 Fax::(360)258-7901 Amount received: PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail:PORPermits@lennar.com Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name:same as above Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: Solar Installation Specialty Code checklist. City/State/ZIP: Permit Fee(includes plan review and administrative fees): $180.00 Phone:( ) Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.: /953' 7 Total fee due upon application: $201.60 Authorized signature: Q4 This permit application expires if a permit is not obtained / within 180 days after it has been accepted as complete. Print name: 17e/ry L La y Date: �2_/?.. /s' *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPennitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application 1 1)12 01 1 1( 1 1 'l t).l \ City of Tigard DEC 2 ! 2015 ReceivedaPermit No.: r,5i-s--Cefa_57, 13125 SW Hall Blvd..Tigard,OR 97223, '•, •i (•A:;7. •Ian Review ■ Phone: 503.718.2439 Fax: 503.598. ¢�.t I t-r t'‘ t-, 1 "DateB•: Other Pennit: I 1 ,n t;n Inspection Line: 503.639.4175 i..,;,t ss. i i _I s',, -.'• > e ReadyBy: /ohs- El See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF WORK PLAN REVIEW ❑New construction 0 Addition/alteration/replacement Please check all that apply(submit 2 sus of plans whims checked below): 0 Service or feeder 400 amps or more 0 Building over three stories. 0 Demolition 0 Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. less to ground,or exceeds 14.000 0 Commercial-use agricultural ❑ 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building amps for all other installations. buildings. ❑Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or 0 Emergency system. larger separately derived syvenr. JOB SITE INFORMATiON_AND LOCATION 0 Addition of new motor load of ❑"A -E",`I-2',"1-3', 100HP or more. occupancy. Job no.: Job site address: 7 e / f 7 �0/ 8 5-W 6 /777 Ave 0 Six or more residential units. 0 Recreational vehicle parks. l CltyiState/Zl : ��An� OR �� �� 0 Health-care facilities. 0 Supply voltage for more than !Ty� 0 Hazardous locations. 600 volts nominal. Suite/bldgiapt.no.: Project name: 0 Service or feeder 600 amps or more. FEE SCHEDULE Cross street/directions to job site: Descrption I to 1 FK. I Total f • , New residential single-or multi-family dwelling unit. Includes attached garage. Subdivision: / 7 -5 Lot no.: 8 1,000 sq.ft.or less ! 168.54 4 ��� ����'C Ls-_s �L 1 Ea.add]500 sq.ft.or portion 4 33.92 1 Tax map/parcel no.: Limited energy,residential 1 75 00 DESCRIPTION-OE WORK (with above sq.ft) 1 Limited energy,multi-family 75 00 residential(with above sq.ft.) - Renewable Energy 0 See Page 2 - Services or feeders installation,alteration,and/or relocation • t.' PROPERTY OWNER ❑ TENANT. 200 amps or less ) 100.70 _ 201 amps to 400 amps 133.56 2 Name: , �1 , Y . I . 401 amps to 600 amps 200.34 . 2 Address: 1 1450-1. Nr I�� 601 amps to 1.000 amps _ 301.04 Rau Ijp� U' v a v�, 7 Over1.000 amps volts 552.26 2 Cin'rState:'ZIP: Oa 1 �g Temporary porary services or feeders installation,alteration,and/or Phone:S iO )��— 1 OO1/41 ' Fax:(o)05fb----viol relocation 200 amps or less 59.36 ! 1 Owner installation:This installation is being made on property that 1 own which is not 201 amps to 400 amps . 125.08 1 2 intended for sale.lease,rent or exchange,according to ORS 447.449.670.and 701. 401 amps to 599 amps 168.54 12 Owner signature: Date: Branch circuits-new,alteration,or extension,per panel j v APPue„AN-T 0 kelp'AC ,PERsom A.Fee for branch circuits with �� 7.42 2 above service or feeder fee. Business name: Ail ' 1/ N\ [ + �r each branch circuit . W V 1 v■ w " B.Fee for branch circuits without Contact name: `/�/��,�/�� 1 �j service or feeder fee,first r l`�' r w' Y" N branch circuit 56.18 ? Address: l I V C �1-1t , -� 1110 Each add]branch circuit 7.42 2 �� ^� Miscellaneous(service or feeder not included) City'StateiZiP: a11c� u\Je' ` , - Clcb�1 -?- L tN t Each manufactured or modular 67.84 2 Phone: /�) > Fax: : dwelling.service andor feeder _ �V�,✓yv,,f,,� L�f� ✓ �/00 ��� 4lJ1 Reconnect only 67.84 2 E-mail: t�f 1 K Ut'r(n `=/ n1� . C Or I 1 Pump or irrigation circle 67.84 CONTRACTOR Sign or outline lighting 67.84 '_ Business name:/0wee 1.�`K \C.Gk x,G '� Signal circuit(sl or limited-energy See panel,alteration,or extension. Page 2 3 Address: 92,1)43' `' yr Etzs , 9, Each additional inspection over allowable in any of the above �t7+; , O - cvn Additionalinspection(I hr min) 66.25'hr City(State;Z1P: ' Investigation I l hr min) 66.25;hr Phone: ) Fax: Industrial plant(1 hr min) 78.18'hr inspections for which no fee is 90.00'hr t CCB Lic.:aoo G Electrical Lie.: C V0 G Suprv. Lic.:5 305 5 specifically listed(st hr mint ELECTRICAL PERMIT FEES Supn.Electrician signature,required: Subtotal: _ ate: Plan review(25%of permit fee): ::::: e: G r K �� , -- State surcharge(12%of permit fee): ed signatur . VO\c.)&,v C"C•J TOTAL PERMIT FEE: This permit application expires if a permit is not obtained nithin 180 Print name: - �eA�. v 0\c�JeJ3G I Date: days after it has been accepted as complete. Number of inspections allowed per permit. I,Bu,ldinePertnitsELC Permliipp_ELR_ERE doe.Rev 05,21:2512 440-46151111.05"COM WEB 1 Mechanical Permit Applicaticr; g �- t ,., m, FOR OFFICE USE ONLY .', e`�"t :-= —" [1-, Received City g of Tigard Permit yr/.. /..:5".....65.2.5.20 Date/By: n 13125 SW Hall Blvd.,Tigard,OR 97223 DEC 2 12015 Plan Review :111111 I Phone: 503.718.2439 Fax: 503.598.1960Da[e/By: Other Permit: TIG,4 R D Inspection Line: 503.639.4175C t - f- -- Date Ready/By: Juris: H See Page 2 for Internet: www.tigard-or.govI 1 i~J;- °w:°+�: Notified/Method: Supplemental Information 1:-.:U 8 L.L Y•l'•.d+ tj 1 X 4 4J t i.v 1 TYPE OF WORK COMMERCIAL FEE* SCHEDULE —USE CHECKLIST Mechanical permit fees*are based on the value of the work N New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all 0 Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ® 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building For special information use checklist. ❑Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning i 46.75 Job site address: /0/78 ,jki'' 67'774 A/L Furnace 100,000 BTU(ducts/vents) 1 46.75 City/State/ZIP: ` ?/..2j2 0 q 72 C3 Furnace 100,000+BTU(ducts/vents) 54.91 / '1/ Heat pump 61.06 Suite/bldg./apt.no.: Project name: Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: d3f.i, 5-2—REE Ss 7-4re-s Lot no.: /g Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 1 23.32 DESCRIPTION OF WORK Gas fireplace/insert 1 33.39 Flue vent for water heater or gas NSFR fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 ® PROPERTY OWNER 0 TENANT Other: 23.32 Environmental exhaust and ventilation: Name:LENNAR NW,INC Range hood/other kitchen equipment 1 33.39 Address:11807 NW 99th Street,Suite 1170 Clothes dryer exhaust 1 33.39 City/State/ZIP:Vancouver,WA 98682 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 5 23.32 Phone:(360)258-7900 Fax:(360)258-7901 Attic/crawlspace fans 23.32 ® APPLICANT 0 CONTACT PERSON Other: 23.32 Business name:LENNAR NW,Inc Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Charles Webb Furnace,etc. Address: 11807 NW 99th Street,Suite 1170 Gas heat pump Wall/suspended/unit heater City/State/ZIP:Vancouver,WA 98682 Water heater Phone:(360)258-7900 Fax::(360)258-7901 Fireplace Range E-mail:PORPermits@Lennar.com Barbecue CONTRACTOR Clothes dryer(gas) •Business name: Wo Other: yG D L O i% Pt. )3 I A)q MECHANICAL PERMIT FEES* I Address: 1©7 5 i4i. �J/s T,RiC Co`gsis/M l;vim a NJ W,/ Subtotal City/State/ZIP: �7 70/ a Minimum permit fee($90.00) /R0 CI%vf� C! OR (OPlan review(25%of permit fee) Phone:(3-01 6 6 7_/78/fr yet Fax:(52,3) 6�7 989/ State surcharge(12%of permit fee) CCB lic.: 1/ 22 2 CO TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: axi.407 * Fee methodology set by Tri-County Building Industry Service Board Print name: (,L//-.._ 1.�IL i/tqn4, Date: .9,/,‘ , /5 1:\Building\Permits\MEC_PemutApp_040113.doc 440-46ITT(11/02/COM/WEB) Plumbing Permit Application Building Fixtures ` i t 4�r FOR OFFICE USE ONLY p !! � City of Tigard :ived Date/By: Permit No•/5 �1.�Qo7�0 111111 O at 13125 SW Hall Blvd.,Tigard,OR 97223 CJ E C 2 1 2 0 i5 Plan Review Other Permit No.: Phone: 503.718.2439 Fax: 503.598.1960 Other T I G A RD Inspection Line: 503.639.4175 (�3 Ff �;Y )+� ,,,Y DQto Ready/By: Iuds: ® See Page 2 for Internet: www.tigard-or.gov (`; y y. r ti: 1448tified/Method: Supplemental Information TYPE OF WORK O t v'a tl N FEE* SCHEDULE ®New construction ❑Demolition For special information use checklist Description Qty. Ea. I Total ❑Addition/alteration/replacement ❑Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ® 1-and 2-family dwelling 0 Commercial/industrial SFR(2)bath 437.78 SFR(3)bath 1 500.32 ❑Accessory building ❑Multi-family Each additional bath/kitchen 25.02 ❑Master builder 0 Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND-� LOCATION Site utilities: Job site address: /e)/78 5f 6 /,, , 4 1/6:: Catch basin or area drain 18.76 Drywell,leach line,or trench drain 18.76 City/State/ZIP: l7'RR �D d 9 223 7 Footing drain(no.linear ft.: ) Page 2 Suite/bldg./apt.no.: I Project name: Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.: ) Page 2 Storm sewer(no.linear ft.:_) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision: OA kr 5-772 S r re S I Lot no.: /8 Fixture or item: Tax map/parcel no.: Backflow preventer 1 31.27 DESCRIPTION OF WORK Backwater valve 12.51 Clothes washer 1 25.02 NSFR Dishwasher 1 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 ® PROPERTY OWNER I 0 TENANT Expansion tank 12.51 Name:LENNAR NW,Inc Fixture/sewer cap 25.02 Floor drain/floor sink/hub 25.02 Address:11807 NW 99th Street,Suite 1170 Garbage disposal 1 25.02 City/State/ZIP:Vancouver,WA 98682 Hose bib 2 25.02 Phone:(360)258-7900 Fax:(360)258-7901 Ice maker 1 12.51 ® APPLICANT 0 CONTACT PERSON Interceptor/grease trap 25.02 Business name:LENNAR NW,Inc Medical gas(value:$ ) Page 2 Primer 12.51 Contact name:Charles Webb Roof drain(commercial) 12.51 Address:11807 NW 99th Street,Suite 1170 Sink/basin/lavatory 5 25.02 City/State/ZIP:Vancouver,WA 98682 Solar units(potable water) 62.54 Phone:(360)258-7900 Fax::(360)258=7901 Tub/shower/shower pan 3 12.51 E-mail:PROPermits$Lennar.com Urinal 25.02 CONTRACTOR Water closet 3 25.02 Water heater 1 37.52 Business name: WO L 'C- `P 77 PL um 8(WV Water piping/DWV 56.29 Address: /U 75 W . lit 57OR/C Cr>Gam/3/A /'fl✓zfe ,/ r: 25.02 city/State/ZIP: 'Wog 7�r4LL-"1 4 970 6.0 Subtotal Phone:(563)66 7, /79/,.,,,,,se/ Fax:(5-'3) ‘6 7_ 578 9/ Minimum permit fee: $72.50 CCB Lic.: / 22200 Plumbing Lic.no.:,24 8 D824 I Plan review (25%of permit fee) State surcharge(12%of permit fee) Authorized signature: t l e.A alG yl TOTAL PERMIT FEE 11 This permit application expires if a permit is not obtained within 180 days Print name: C�-/^F 8,,,,,,,,,, Date: 2,/(G /5 after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\PLMU-PermitApp.doc 10/01/09 440-4616T(10/02/COM/WEB) City of Tigard ■ COMMUNITY DEVELOPMENT DEPARTMENT T I G A R D Building Permit Review — Residential Building Permit #: /ffj/5'-Doa3-6e Site Address: /9/ Si ) c /A /9ve Project Name: CZ ,L S . s"-LZ "-c) Lot #: /F (New dwelling= subdivision name;,Addition or.Alteration=last name of owner) Planning Review Proposal: /tie& � 2 Ll- Verify site address/suite# exists and active in permit syste .. River Terrace Neighborhood: ❑ Yes I1X No Sil ,�Plan Elements: Tree (3)copies of site plan J fisting structures on site e plan must 1>e on 8-1/2"x 11"or 11 x 17"paper Yi Footprint of new structure (including decks)with finished lawn to scale (standard architect or engineer scale) '•or elevations rth arrow hl Utility locations(required for new,may apply for additions) e address,project or subdivision name and lot number ill'ocation of wells/septic systems licant information(name and phone number) 1i Erosion control(including drainage-way protection,silt fence 11 ot dimensions and building setback dimensions sign,location of catch basin,etc.) 1!�1 of area,building coverage area,percentage of coverage and Vreet names Prpervious area (applicable if R-7,R-12,R-25&R-40) Street tree size,type and location operty corner elevations (2 foot contour lines if more than taAusting trees to be retained with drip line,and tree 4 foot differential) protection measures Clean Water Services—Service Provider Lette of platted prior to 9/10/1995): equired: ❑ Yes,applicant was notified No Received: El Yes ❑ No ei Public Facilitie mprovement (PFI) Permit: Required: Yes,applicant was notified ❑ No Applied For: Yes ❑ No,stop intake �kand Use Case #: 71445.20/171� �/ �/ oning: Setbacks: Front ,q0 Rear /S Side Street Side /5 Garage 9O o'CS / Landscape Requirement: 0/0 //1 ot Coverage Maximum: i, Building Height: Maximum I leight 30, Actual Height CCS OPVisual Clearance kasements ensitive Lands: ❑ Yes l(No Type an Forestry Plan Conditions "Met" prior to issuance of building permit Notes: Approved By Planning: L=__--.,..- � t_ %C..- Date: 42A/ /,— Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved E Not Approved l::\Building\Fonns`BldgPennitRvw_RES_070915.docx r Building Permit Submittal Original Submittal Date: /a/a VA.5'. Site Plans: # 5 Building Plans: # �' Building Permit#: [Enter building permit#above. Workflow Routing: CIPlanning B Engineering Permit Coordinator 'El—Building Workflow Sign-off: ['Sign-off for Planning(include notes from planning review) Route Application Documents: rr Engineering: (1) copy of permit application, (1) site plan, (1) building plan and � original plan review routing form. E Building: original permit application, site plans,building plans, engineer and beam calculations and trust details,if applicable, etc. Notes: By Permit Technician: "<aS:5447-7(- -r a Date: /2/2 /'S Engineering Review Slope at building pad: 'Conditions "Met"prior to issuance of building permit 'Water Easements (encroachments) per engineering conditions of approval and plat Quality/Quantity Facility: Assess Water Quality Fee in-lieu: E Yes ❑ No Assess Water Quantity Fee in-lieu: ❑ Yes ❑ No LIDA Facility on lot: ❑ Yes ❑ No ❑ NOT Approved by Engineering: Date: Notes: Approved by Engineering: 4L 1 Date: 46 Revisions (after Building Submittal only) Reviewer Date Revision 1: E Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Permit Coordinator Review ❑ Conditions "Met"prior to issuance of building permit ❑ Approved, NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: SDC Fees Entered: Wash Co Trans Dev Tax: [1J Ycs ❑ N/A Tigard Trans SDC: ❑ Yes gPN/A Parks SDC: V Yes E N/A K to Issue Permit Approved by Permit Coordinator: 79Date: / i c I:ABuilding\Forms\BldgPennitRvw_RES_0709!5.docx /tr�- TIGARD City of Tigard March 9, 2016 Lennar Northwest Inc. Attn: Juls Call 11807 NE 99th St., Suite 1170 Vancouver,WA 98682 Re: Permit No. Various New SF Residential Permits - See Attached List Dear Applicant: • The City of Tigard has processed a refund for fees on the above referenced permit(s) as follows: Site Address: Various Project Name: Oak Street Estates - Lots 1-23 and 25-31 Job No.: Refund: ® Check #220393 in the amount of$338,059.00. (1 Credit card "return" receipt in the amount of$ Note: Please allow 2-5 days for this refund transaction to be credited to your account by the company that issued your card. n Trust account "deposit" receipt in the amount of$ Comments: Refund for SDC fees paid prior to available credits applied from demolition permit BUP2015-00091 for armory building and SF residential building. See attached spreadsheet for SDC credit balance and list of permits that credits were applied to. If you have any questions please contact me at 503.718.2430. Sincerely, /.6)Dianna Howse Building Division Services Supervisor Enc. 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.639.4171 Y City of Tigard TIGARO, Accela Refund Reque t This form is used for refund requests of land use, development engineering and building permit application fees. Receipts, documentation and the Request for Permit Actio. form (if applicable)must be attached to this request form. Refund requests are due to Accela S-ystem Administrator by each Wednesday at 5:00 PM. Please allow up to 3 weeks for processing of refunds. Accounts Payable will route refund checks to Accela System Administrator for distribution to applicant. PAYABLE TO: Lennar Northwest Inc. DATE: Attn: Juls Call 3/7/2016 11807 NE 99th St., Suite 1170 REQUESTED BY: Dianna Howse Vancouver,WA 98682 TRANSACTION INFORMATION: Receipt#: Various Case #: Date: Various Various Pay Method: Various Address/Parcel: Various Project Name: Oak Street Estates EXPLANATION: Refund for transportation development and parks system development fees paid prior to demolition credits for armory structures and (1)residential structure. Received final inspection for BUP2015-00091 on 2/10/2016 so credits cart be applied and all SDC fees paid by developer shall be refunded. REFUND INFORMATION: Fee Description From Receipt Revenue Account No. fund Exam ple: Buildin: Permit Fee Exam ple: 2300000-43104 Remount Washin•ton Coun Trans portation Development Tax 405-0000-43320 $Aount $237,723.00 Parks SDC-Improvement 425-0000-43300 Parks SDC-Reimbursement 425-0000-43301 20,203.00 Sewer Connection 500-0000-25500 3,633.00 X1*44:00 IMMINEMIEMEMINIMI TOTAL REFUND: ,$ 33971 APPROVALS: SIGNAT S DATE: lro If under$5,000 Professional Staff MAW If under$12,500 Division Manager If under$25,500 Department Manager If under$50,000 City Manager If over$50,000 Local Contract Review Board v/7 s FOR TIDEMARK SYSTEM ADMINISTRATION USE ONLY Case Refund Processed: Date: B : ,4am