Loading...
Report (54) " v v<<-/-- ovrUc,. Cvltiy SA) 4Js1 ccgz coWorldwide www Fire Protection contacts REOFIVE[ Products JUN 1 1 20X Series TY-B, 5 6 K-factor Ct� �TGAHD Upright, Pendent, and Recessed Pendent SpritiMM fIISIO Standard Response, Standard Coverage General NOTICE ,r- The Series TY-B Sprinklers described "' - r.'"Ii Description herein must be installed and maintained in compliance with this document, as ---, The TYCO Series TY-B, 5.6 K-factor, well as with the applicable standards ' .. Upright(TY315)and Pendent(TY325) of the National Fire Protection Associa- S Sprinklers described in this data sheet : i P tion,in addition to the standards of any $ _ . are standard response,standard cover- other authorities having jurisdiction. age,decorative 5 mm glass bulb type Failure to do so may impair the perfor- Mai t # spray sprinklers designed for use in mance of these devices. = ' light, ordinary, or extra hazard, corn- The owner is responsible for maintain- m tell, occupancies such as banks, in their fire system and Y hotels, shopping malls, factories, g protectionY refineries,and chemical plants. devices in proper operating condition. The installing contractor or sprinkler The recessed version of the Series manufacturer should be contacted with TY-B Pendent Sprinkler, where appli- any questions. cable,is intended for use in areas with a finished ceiling.This recessed pendent sprinkler �+uses one of the following: Sprinkler er 9 p • A two-piece Style 15 Recessed Identification \ Escutcheon with recessed adjust- �'� adjust- ment up to 5/8 inch (15,9 mm)from , ? the flush pendent position. Numbers (SINS) , R i ;„, , • A two-piece Style 20 Recessed TY315 Upright 5.6K, 1/2"NPT �; Escutcheon with recessed adjust- TY325 Pendent 5.6K, 1/2"NPT , ;Prs:, ment up to 1/2 inch h (12,7 mm)fromRkei ,- the flush pendent position. Technical The adjustment provided by thet Daa Temperature Ratings 135°F 57 C Recessed Escutcheon reduces the ( ) accuracy to which the fixed pipe drops 155°F(68°C) to the sprinklers must be cut. Approvals 175°F(79°C) UL and C-UL Listed 200°F(93°C) Intermediate level versions of Series FM,LPCB,and VdS Approved 286°F(141°C) TY-B Sprinklers are described in CE Certified 360°F(182°C)t Technical Data Sheet TFP352.Sprinkler guards and shields are described in Sprinklers with Polyester Finish are 1-UL,C-UL,and VdS Approved only Technical Data Sheet TFP780. UL and C-UL Listed as Corrosion- Finishes Resistant Sprinklers. Sprinkler:Refer to Table A Maximum Working Pressure Recessed Escutcheon:White Coated, 175 psi(12.1 bar) Chrome Plated,or Brass Plated 250 psi(17.2 bar)' *The maximum working pressure of 250 psi Physical Characteristics 17 ( .2 bar)only applies to the listing by Un- Frame Bronze IMPORTANT derwriters Laboratories,Inc.(UL). Button Brass/Copper Always refer to Technical Data Sealing Assembly Stainless Sheet TFP700 for the "INSTALLER Discharge Coefficient Steel w/TEFLON WARNING" that provides cau- K=5.6 GPM/psiliz(80,6 LPM/barli2) Bulb Glass tions with respect to handling and Compression Screw Bronze installation of sprinkler systems and Deflector Bronze components.Improper handling and installation can permanently dam- age a sprinkler system or its compo- - nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP152 TFP152 Page2of4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* ��..... — 1 5 �=5 7/16" 1 / (11,1 mm) = I } ��1 c 4 NOMINAL 2" } fl ( �l MAKE-IN ' (50,8 mm) I /- 2 r 2" 1-3/8" 3 bI rf (50,8 mm) (34,9 mm) I Or G I WRENCH 1 / FLATS f _1 1/2"NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. --- CROSS —CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE L, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY315) and Pendent(TY325) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to ons FIGURE 2 activate and water to flow. General Do not install any bulb type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss of SPRINKLER WRENCH Design liquid from the bulb.With the sprinkler held horizontally, a small air bubble WRENCH Criteria should be present.The diameter of the RECESS The TYCO Series TY-B, 5.6 K-factor, air bubbler theap135°F (57y )1/16o inch (1,6 mm) for 135 F (57 C) to 3/32 Upright(TY315)and Pendent(TY325) inch (2,4 mm) for the 360°F (182°C) sl0yr Sprinklers are intended for fire protec- temperature ratings. tion systems designed in accordance 11 with the standard installation rules A leak-tight 1/2 inch NPT sprinkler recognized by the applicable Listing joint should be obtained by applying a or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14 is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels .1.....0. 13, and FM Approval is based on the of torque may distort the sprinkler inlet PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the IN TO ENSURE tion Data Sheets). Only the Style 15 sprinkler. ENGAGEMENT or Style 20 Recessed Escutcheon, as Do not attempt to compensate for WITH SPRINKLER applicable, is to be used for recessed insufficient adjustment in the escutch- WRENCHING AREA pendent installations. eon plate by under-or over-tightening FIGURE 3 the sprinkler. Readjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP152 Page 3 of 4 Step 3.Tighten the sprinkler into the 2-7/8"DIA• . sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench (Figure 2). With reference to Figure 1,apply the W-Type 2 6 Sprinkler Wrench to the wrench flats. — Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER CE OF (5577,,22 mm)DIA. 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers \ _ on FLUSH f_------ The Series TY-B Recessed Pendent 3/8±5/16" 1 I f Sprinklers must be installed in accor- (9,5±7,9 mm) %71 i •v % ` +I dance with the following instructions. } i J� Step A.After installing the Style 15 or t-1 1/8" i I MOUNTING Style 20 Mounting Plate,as applicable, SURFACE (3,2 mm) over the sprinkler threads and with - - — pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) threads,hand-tighten the sprinkler into TY-B PLATE the sprinkler fitting. 3/4"(19,1 mm) Step B.Tighten the sprinkler into the FIGURE 4 sprinkler fitting using only the W-Type SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) 7 Recessed Wrench(Figure WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 Sprinkler 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After the ceiling is installed or SPRINKLER 2-1/4"DIA. the finish coat is applied, slide on the FITTING (57,2 mm) Style 15 or Style 20 Closure over the 5/16±1/4" 1/2" 12,7 mm Series TY-B Sprinkler and push the (7,9±6,4 mm) ( ) Closure over the Mounting Plate until + - FLUSH its flange contacts the ceiling. / _1 Care and t ' 1/8" J Maintenance SOURFACE -UNTING (3,2 mm) The TYCO Series TY-B, 5.6 K-factor, " 1 Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-B PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) main control valve for maintenance WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. The owner is responsible for the system from the proper authorities Sprinklers that have been exposed to inspection,testing,and maintenance of and notify all personnel who may be corrosive products of combustion, but their fire protection system and devices affected by this action. have not operated,should be replaced in compliance with this document, as Absence of the outer piece of an if they cannot be completely cleaned by well as with the applicable standards escutcheon, which is used to cover wiping the sprinkler with a cloth or by of the National Fire Protection Associa- a clearance hole, can delay sprinkler brushing it with a soft bristle brush. tion (e.g., NFPA 25), in addition to the operation in a fire situation. Care must be exercised to avoid dam- 1standards of any other authorities hav- The owner must assure that the age to the sprinklers-before, during, ing jurisdiction. Contact the installing sprinklers are not used for hanging and after installation. Sprinklers dam- contractor or sprinkler manufacturer p 9 9 regarding any questions. any objects and that the sprinklers are aged by dropping, striking, wrench only cleaned by means of gently dust- twist/slippage, or the like, must be Automatic sprinklers are recommended ing with a feather duster; otherwise, replaced. Also, replace any sprinkler to be inspected,tested,and maintained non-operation in the event of a fire or that has a cracked bulb or that has lost by a qualified Inspection Service in inadvertent operation may result liquid from its bulb. (Ref. Installation accordance with local requirements Section.) and/or national codes. • Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- Thereafter, annual inspections per sion must be replaced. NFPA 25 are required;however,instead of inspecting from the floor level, a . Automatic sprinklers must never be random sampling of close-up visual painted, plated, coated, or otherwise inspections should be made. altered after leaving the factory. TFP152 Page4of4 P/N* 77 - XXX - X - XXX I � SIN SPRINKLER TEMPERATURE FINISH RATINGS 570 5.6K UPRIGHT(1/2-NPT) TY315 1 NATURAL BRASS 135 135°F(57`C) 571 5.6K PENDENT(1/2-NPT) TY325 3 PURE WHITE(RAL9010)" 155 155°F(68°C) POLYESTER •Use suffix"I"for ISO 7-1 connection; SIGNAL WHITE(RAL9003) for example,77-570-4-175-1 4 POLYESTER 175 175`F(79°C) 9 CHROME PLATED 200 200°F(93°C) Eastern Hemisphere sales only P66 286°F(141°C) 360 360°F(182°C) 000 OPEN"* OPEN indicates sprinkler assembly without Glass Bulb, Button,and Sealing Assembly TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating,(specify)finish,P/N (specify,refer to Table A) Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N(specify*) Specify:Style 20 Recessed Escutcheon with(specify*)finish, P/N(specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright®2014 Tyco Fire Products,LP. All rights reserved. two TEFLON is trademark of The DuPont Corporation. Fire Protection Products Dyna-Thread® - M-COAT® Submittal Data Sheet - t Full Line Sch-40 Replacement Dyna-Thread—M-COAT Specifications Dyna-Thread"—M-Coat` sprinkler pipe represents an engineering NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR advancement for the sprinkler pipe industry.It combines the safety In;mm In;mm Lbs/Ft kg/m Lbs/Ft kg/m Unthreaded Threaded and longevity of traditional Sch-40 pipe with quality and superior 1" 1.080 1.330 1.75 11.39 1.00 hydraulic advantages. 25 27.4 2.0 2.60 — — 11/4" 1.408 1.870 2.54 9.50 1.00 ® Comparison to Schedule 40 32 35.8 2.8 3.78 — — 1'h" 1.639 2.290 3.22 9.14 1.00 Dyna-Thread'—M-Coat inside diameter is up to 3.6% larger than Sch-40 40 41.6 3.4 4.79 — — giving it superior hydraulics.Also,when used in combination with Dyna- 2" 2.104 3.050 4.57 8.41 1.00 Flow—M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 — — approved UL, ULC,and FM for fire sprinkler applications.The life expectancy of Dyna-Thread—M-Coat and Sch-40 are equal based on the calculated wall 0 a® i thicknesses per UL.The consistent quality of steel used to make Dyna-Thread— APPROVED M-Coat facilitates smooth threading and lower maintenance costs.The exterior of Dyna-Thread—M-Coat is protected by a clean,durable mill coating for O American Made extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available - arrd lighter weight, Dyna-Thread—M-Coat reduces installation fatigue and through distributors in the USA,Canada,Mexico,and is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR) is a UL Latin America. (Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. • This is based on the calculated wall thickness at the base of the first exposed O Specifications & Approvals thread,assumed to be the weakest point of the pipe length.Dyna-Thread— M-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread—M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with NFPA-13.All sizes of Dyna-Thread—M-Coat are rated at 300 psi working O Comparison to L.W.T. Pipe pressure.Dyna-Thread—M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread—M-Coat dry and pre action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints.Dyna-Thread— use in wet systems. Dyna-Thi ead—M-Coat is approved for all M-Coat is approved for standard hanger spacing(I 5 ft.O.C.),can be used as threaded couplings and welded outlets and is suitable for all earthquake sway bracing,and is safe to use as drops.Dyna-Thread—M-Coat roll grooved,and plain end fittings.(See listing information). is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread—M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: 9'allied Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com • 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUIT' Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 .PART O;�atkOre ©2013 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1301 SMITHCOOPNIR® INTERNATIONAL Ductile Iron Threaded Fittings Specifications • © branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • Ductile iron castings conform to ASTM A536 ®L us LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 4:/;* • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300#Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 ,,,,,,,,4, -1,-, Ind! e ron filings - ass I I 1 / QUALITY PLUS • C4141,1US 441(1> APPROVED LISTED A Fig. 35E 3-90°Elbow Size Part Number A Packing Weight rg� In in Inner Master lb __lair. 1/2 35E 3004 1.13 100 200 0.2 lo. 3/4 35E 3006 1.31 70 140 0.3 - 4. I • �% A 1 35E 3010 1.50 40 80 0.5 d 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow B Size Part Number A B Packing Weight is.. in in in Inner Master lb IIII .� 3/4x 1/2 35RE3006004 1.20 1.22 80 160 0.3 •� 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 �.• i 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 �_ � 4 1-1/4x1/2 35RE3012004IS 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 - 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 rt, 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 4'' 1 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 l'''.. .- ..1 4j4 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 s 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow f.#, Size A Packing Weight Part Number }- IA in in Inner Master lb r, x a €%,. / �, 1/2 35F 3004 0.88 150 300 0.2 ,,••• 3/4 35F 3006 0.98 80 160 0.3 �., • 1 35F 3010 1.13 40 80 0.5 4 �� 1-1/4 35F 3012 1.29 25 50 0.7 i A 1-1/2 35F 3014 1.44 20 40 1.0 Ali-d., 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee • Size Part Number A Packing Weight in in Inner Master lb "` ( A 1/2 35T 3004 1.13 80 160 0.3 MIMI 3/4 35T 30061 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 w, 1` 1-1/4 35T 3012 1.75 10 20 1.1 A A 1-1/2 3513014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 • 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.sminccuoper.cum IL Threaded Accessories B3205 -Threaded Rod (right-hand threads- both ends) (T0LCO Fig.103) ,/'', 63205E -Threaded Rod (right&left hand threads) / TL Size Range: 3/8"-16 thru 3"-4 rod s Length \llll�lll�l�� Material: Steel / Function: Recommended for use as a hanger support in hanger assemblies. / Ti �\ Rod is threaded on both ends with right hand threads of the length shown.Also \ �ll� available with left and right hand threads-specify Fig. B3205L when ordering. e„, A Thread Size Maximum Temperature: 750°F(399°C) " Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number,rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8X'1' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 133205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 83205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x ILI 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 83205-7/8 x 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) 83205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/8 x'L' 11/8"-7 41/2" (1143) 7450 (33.14) 5830 (25.93) 83205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (4225) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (46.07) 83205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21/4 x ILI 21/0-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 83205-21/2 x'1.' 21/2"4 10" (254.0) 39800 (177.03) 31169 (138.64) 83205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths civic()Fig.100 ) Fig.99-All Threaded Rod Cut To Length e,, Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length 'ii4) ,,,,,,\``�' Material: Steel C ����,' w �d Maximum Temperature: 750°F(399°C) `o Finish: Plain.Contact B-Line for alternative finishes and materials. <<` 2 m ' Order By: Part number,rod diameter and finish � Q Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/8"x length 16 730 (324) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 3/4"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) • AIR 7/8"x 120 99-7/8"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. • Pipe Hangers&Supports Revised 4:28/2014 B-Line 236 by E:T•N 1 Pipe Hangers Fig.200- "Trimline"Adjustable Band Hanger (B-Line Fig.B3170NF) ®TOLCO Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) UL us Fig.200C- "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig.200S - "Trimline"Adjustable Band Hanger with Non-Captured Nut Size Range: Fig.200 - 1/2" 115mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications s Function: For fire sprinkler and other general piping purposes. Knurled /w swivel nut design permits hanger adjustment after installation. � Features: ea • (1/2" (15mm) thru 2" (5omm)) Flared edges ease installation for all pipe _ types and protect CPVC plastic pipe from abrasion.Captured design :, keeps adjusting nut from separating with hanger. Hanger is easily a e installed around pipe. A j For hanger with non-captured nut order Fig. 200S. • (21/2" (65mm)thru 8" (2o0mm))Spring tension on nut holds it securely in ;'✓ � -- hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) Fig Zoo+h 20030 in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and r Factory Mutual Engineering Approved(FM)(3/4" (20mm)thru 8" (200mm)). Fig.200-1 to 200-2 Fig.200-21/2 to 200-8 Conforms to Federal Specifications\ N-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, .._.�, Type 10. Maximum Temperature: 650°F(343°C) " Finish: Pre-Galvanized. Stainless Steel •' materials will be supplied with (2) hex nuts / in place of a knurl nut. 11. Order By: Figure number and pipe size r' Designed to meet or exceed requirements of • \: M FMDS2-0. , ' . Fig.200 Fig.200C Fig.200E 40111. Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8'"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) • 200-1 1" (251 3/8"-16 33/s" (85.7) 25/8" (66.7) 12 (5.5) " 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.91 200-11/2 11/2" (401 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) . 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 4. 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/8"-16 57/s" (149.11 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/s"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8'"-16 73/8" (187.3) 5" (127.0) 35 (16.01 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131 8" (333.4) 83 4" 222.2 136 (62.3) / / 1 1 All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions B-Line 21 by E:T•N