Plans (2) oU `a DSC � 2 2015 Connect new 16ga welded grease duct to existing duct form previous hood. blank off 2 hour rated shaft and continue grease duct wrapped with fire master fire wrap I New hood NEW CEILING ASSEMBLY 5/8"TYPE'X'GYPSUM BOARD 1 ON 18 ga 8"STEEL CHANNELS 24"0/C W/5/8"TYPE'X'GYPSUM CEILING FINISH 2 502 T.EXISTG FLOOR LINE/ _ T.PARPET _ _ SEE KEYNOTE#21 I x —J B.CEILING JOISTS 9 5 B.HEADER SEE RCP 6 B.FRAMING NEW FLOOR ASSEMBLY 8 B.HOOD FRAME NEW WOOD-FRAMED 8 4 FLOOR ASSEMBLY W/FINISH 20 ;o FLOORING OVER j"TBG PWD q + DECKING ON 2 X10 DF#2 JOISTS @ 16"0/C T.DIEWALL 14 0 A50 7 � r A — 4 I DRY STORAGE 13 COOK TO 1 114 ORDER ATR/UM 111 ==y4A 3. COOK-TO-ORDER SECTION SCALE: 1/4"=1'-0" SECTION KEYNOTES OTYPE I EXHAUST HOOD TO CONNECT TO EXISTING SIDEWALL EXHAUST DUCT. 10 NEW OVERPOURED FLOOR ASSEMBLY—SEE SHEET A207 19 MILLWORK BEYOND—SEE SHEET A206 HOOD TO BE SUPPORTED BY ALL THREAD RODS TO NEW STEEL FRAMING ABOVE- ENGINEERING BY DEFERRED SUBMITTAL. 11 NEW OVERPOURED CONCRETE RAMP—SEE 1/A206 FOR 20 FRAME ON TOP OF AND DOWN FACE OF EXISTING WF STEEL BEAt DIMENSIONS AND STRUCTURAL FOR REINFOREMENT AND OHORIZONTAL DUCT TO RECONNECT TO EXISTING SIDE WALL HOOD DUCT SUB GRADE PREP 21 REMOVE CONCRETE TOPPING SLAB AND METAL DECKING TO AC( ASSEMBLY. EXHAUST HOOD DUCTING AND INSTALLATION—SEE SHEET A404 F 12 NEW 1-1/2"DIA PREFINISHED STEEL HANDRAIL W/BRACKETS DIMENSIONS FOR HOOD OPENING �" O3 VERTICAL SECTIONAL DOOR-SEE 1/A206 FOR TS POST LOCATIONS AND RELATED MOUNTED AS SHOWN. -- DETAILS 13 EDGE OF NEW THICKENED CONC SLAB—SEE INTERIOR DRAWINGS OEXISTING 2ND FLOOR GUARDRAIL BEYOND-SEE ELEVATIONS FOR TILE FINISH OSTEEL TRELLIS HUNG FROM FASCIA 14 SEE INTERIOR DRAWINGS FOR TILE BASE BEYOND OEXISTING WF STEEL BEAM,SEE RCP 15 UNDERSIDE OF SECOND FLOOR ASSEMBLY ABOVE O7 6"METAL STUD DIE WALL FOR SERVERY-SEE MILLWORK DRAWINGS,BY OTHERS 16 EXISTING 1-HR RATED GYPSUM BOARD SOFFIT OR CEILING ASSEMBLY O$ NEW SUSPENDED CEILING ASSEMBLY-SEE RCP 17 NEW 1-HR RATED GYPSUM SOFFIT--SEE SHEET A403 FOR DIMENSIONS OEXISTING WALL ASSEMBLIES 1$ BARN STYLE DOOR/TRACK ASSEMBLY 18 BARN STYLE DOOR/TRACK ASSEMBLY BEYOND NIAERCOLLECHJN rrFICIENCY HOOD INFORMATION FILTER(S) LIGHTS) UTILITY CABINETS) FIRE HOOD HOOD TAG EFFICIENCY @ 9 WIRE FIRE SYSTEM ELECTRICAL SWITCHES SYSTEM-IANGIN NO. TYPE QTY.HEIGHT LENGTH MICRONS QTY. TYPE GUARD LOCATION TYPE SIZE MODEL # QUANTITY PIPING WGHT 1 Captrate Solo Filter 9 20' 16' 93% See Fitter Spec. 4 L55 Series E26 NO YES 651 5 LBS HOOD INFORMATION — Job 2381140 MAX. EXHAUST PLENUM HOOD CONFIG. = HOOD RISERS) HOOD NO TAG MODEL LENGTH COOKING TOTAL CONSTRUCTION END TO ROW TEMP. EXH. CFM WIDTH LENG. DIA. CFM S.P. END FOR QUESTI❑NS, CALL 5424 10' 33' 3300 —0.840' 430 SS KURT CURTIS: REGIONAL MANAGER 1 13' 1.00' 600 Deg. 3300 ALONE ALONE PHONE, (360) 828-5418 ND-2 Where Exposed FAX, (919) 227-5983 PARTICLE DIAMETER(um) HOOD OPTIONS EMAIL, kurt.curtisl2captivealre.com HOOD TAG OPTION NO. LEFT END STANDOFF (FINISHED) 1' Wide 54' Long Insulated RIGHT END STANDOFF (FINISHED) 1' Wide 54' Long Insulated 1 INSULATION FOR TOP OF HOOD INSULATION FOR BACK OF HOOD FINISHED BACK— ISL/REV INSTALL 157.00' Long L55 SERIES E26 CANOPY LIGHT FIXTURE — CaptiveAire Captrate Solo Filter HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL ETI-Listed Grease Extracting Pipers AND SHOCK RESISTANT GLOBE (1-55 FIXTURE) Made From 430 Stainless Steel 1' LAYER OF INSULATION FACTORY INSTALLED 54' ON TOP OF HOOD, MEETS 0 INCH Filter Detail EXHAUST RISERREQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES HANGING ANGLE 20' CAPTRATE SOLO FILTER WITH HOOK 1' LAYER OF INSULATION FACTORY INSTALLED IN 3' INTERNAL STANDOFF. MEETS 0 INCH REQUIREMENTS FOR 24' NOM. CLEARANCE TO COMBUSTIBLE SURFACES. Grease cup will be supported by 2 studs ' —on the inside wall of the hood.The grease will drain through a concealed grease trough and into this removeable cup. 1/2 Pint Grease Cup Detail I/a'Dw ALL THREAD ROD I/]•DIA WAVY obit Nur COMtMM TO ROOF JOW ONE ABOVE Aim OW BEIDM' �ANOTHM HANoac ""NG°�ANQX 48.0' MAX GREASE DRAIN WITH REMOVABLE CUP 78' AFF REFERENCE ROD AM)NUI$TO BE SUPP M BY RMAWK CONTRPMM KAMM ANGLE IS PRE-PUNCHED AT FACTORY ND-2 HANGING ANGLE DETAIL EQUIPMENT HANGING ANGLES WILL BE LOCATED BY OTHERS IN THE FOLLOWING LOCATIONS FOR WAL.I..CANOPIES DIM DIM DIM FROM FROM HOOD S`[Yl-. FROM FRONT FRONT REAR (24"High (30"High Hood) lfood) Wall Exhaust 2.25" 225" Only 4.166" With MIJA 2.25" 1 2.25" ExhaustSECTION VIEW - MODEL 5424ND-2 Back Only 2.2� 2'25 4.166" HOOD - #1 Shelf With MIJA 2.25" 2.25" Condensate 225" 225" JOBEMBASSY SUITES @ WASHINGTON SQUARE HANGING ANGLE LOCATIONS „m, AM LOC,4TION TIGARD, OR, 97223 012tertak DATE 11/16/2015 JOB 2381140 G La Df-0 # 1 DR4#J'V BY REV SCALE 3/8' = 1'-0' 1' LAYER OF INSULATION FACTORY INSTALLED IN INTERNAL BACK STANDOFF, MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 3' FOR QUESTI❑NS, CALL 10, —_ _________I_ KURT CURTISt REGIONAL MANAGER PHONE, (360) 828-5418J— FAX (91 227-5983 SEE TEMP EMAIL kurt.curtitis@captiveaire.com 33, SENSOR DETAIL 54' U.L, Listed L55 Series E26 Canopy Light Fixture - High Temp Assembly o� O Q 78 1/2' 1 78 1/2' 13' 1.00'Nom./13' 1.00'❑D 13'-3.00' Overall Length PLAN VIEW — Hood #1 13' 1 .00" LONG 5424ND-2 PLENUM PROTECTION NOZZLE DUCT PROTECTION NOZZLE DETECTORS DETECTION LINE / r / / / / APPLIANCE PROTECTION NOZZLE AGENT LINE I I I I TYPICAL ANSUL R102 SYSTEM LAYOUT REMOTE WITH REMOTE MOUNTED AUTOMAN SYSTEM CONTROL AUTOMAN MANUAL WITH AGENT TANK ENCLOSED PULL STATION JOBEMBASSY SUITES @ WASHINGT❑N SQUARE 0oltalok * � ®�® LOCATION TIGARD, ❑R, 97223 DATE 11/16/2015 JOB 2381140 .0%. 1>WG # 2 P)Z4YN BY REI! SCf1LE 3/8' = 1'-0' ELECTRICAL PACKAGES — Job 2381140 NO. TAG PACKAGE # LOCATION SWITCHES OPTION FANS CONTROLLED LOCATION QUANTITY TYPE 0 1 H.P. JVOLTJ FLA Room Temperature Sensor 1 SC-310110FP Wall Mount In SS Box SS Wall Mount Box 1 Light Smart Controls Thermostatic Control Exhaust 3 1.500 460 2.5 1 Fan F-1 3 ,25 " TEMPERATURE SENSOR / 211 �- — — — — — — — � HOOD LIGHTS Provides room override based on temperature differential between the room and duct, Install on a wall in space but not directly under the hood or I SECURE TO WALL close to an appliance so the I WITH 4 SCREWS reading is accurate for space, \ ROOM TEMPERATURE O SENSOR DIGITAL USER INTERFACE THERMISTOR INSTALLATION NOTES,One Thermistor per Exhaust Riser Thermistor has 2 whes that connect to control cahhet 14 x 18 x 6 SS Box WALL MOUNTED CONTROL CENTER ur"Sd ow.0.r B*) . 5 , 50 // x`11 O " va-1 yr M.1t r mai yr ow xa aoa vao-) �r wr ur sa ow Th.,Wv T.W e / FOR QUESTI❑NS, CALL � S-.W.C.-as-WO, O O KURT CURTIS, REGIONAL MANAGER PHONEi (360) 828-5418 I FAX, (919) 227-5983 EMAIL; kurt.curtis@captiveaire.com V7 Cosa ua On MUTE FAULT ORESET • 5 O IT IS THE RESPONSIBILITY ❑F THE EC TO MAKE ALL FIELD O LIGHTS FANS O CONNECTIONS INTO AND OUT OF THE CAPTIVEAIRE CONTROL PANEL INCLUDING BUT NOT LIMITED TO LOW VOLTAGE, CAT 5, 24V WIRES TO ALL TEMP SENSORS, INCLUDING THE ROOM TEMP SENSOR, MOTOR LINE VOLTAGE POWER FEEDS, AND CONTROL O O WIRING, REFER TO WIRING SCHEMATICS IN THIS DRAWING AND POSTED INSIDE OF THE CONTROL CABINET DIGITAL JOBEMBASSY SUITES @ WASHINGTON SQUARE USER INTERFACE a *0 us (f VEV �® LOC•9TION T IGARD, OR, 97223 CA FTJ 1>4TE 11/16/2015 JOB # 2381140 Intertek P#V # 3 D)ZAlYN BY REV SCALE 3/8' = V-01 JOB NO MODEL NUMBER DRAWN BY ' SCHEMATIC TYPE DESCRIPTI❑N OF OPERATION: 2381140 SC-310110FP INSTALL 3 Phase •/ control for 1 Exhaust Fan, Exhaust on In Fire, Lights out In Fire, Fan(s) On/Off Thermostatically JOB NAME DATE DWG NO Controlled. Room temperature sensor shipped loose for field Installation. EMBASSY SUITES @ WASHINGTON S... 11/16/2015 ECP #1-1 1 I 2 HOOD LIGHTS I BREAKER PANEL TO CONTROL PANEL CONTROL PANEL1 -----------BLACK =- Responsibility) Electrician TO 1 GREEN ——J 3 BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED HOOD LIGHTS N ——————————— —— 1400 W MAX WIRE TO J-BOXjON TOP OF HOOD BREAKER PANEL CONTROL PANEL 4 Hot — CONTROL PANEL T1A -------------- --- BREAKER IPH ______________ Neutrol — H1 TO T1 WIRE TO CONTROL BOARD, — , N1 ROOM TEMP 120 VGround _ KITCHEN TEMP SENSOR MOUNTED IN ROOM AWAY ----------------- 5 15 A CONTROL POWER, D❑ NOT WIRE SENSOR FROM HEAT SOURCES. SEE MANUAL TO SHUNT TRIP BREAKER. 6 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL PANEL T 2 —————— CONTROL POWER. SWITCH #1 TO WIRE TO CONTROL BOARD. HDOD 1 ______________LINE — L1 DUCT SENSOR SENSOR MOUNTED IN EXHAUST DUCT RISER 1 7 BREAKER 3PH ---- --------- LINE- 460 V ________________LINE — �i 5� THE FOLLOWING CONNECTIONS MCA- 3.1 A _______________Ground —_� MAY OR MAY NOT BE g MOCP IS AE X H-1 REQUIR D BASED SPECIFICATIONS BSITE HOT TO SHUNT COIL SHUNL COIL 9 CONTROL PANEL-————— — --, SIGNAL FOR �—— NEUTRAL FROM SHUNT COIL EXTERNAL ST TERMINAL IS ENERGIZED ID CONTROL PANEL TO FANS SHUNT TRIP IN FIRE CONDITION, Responsibility, Electrician COMMON CONTROL PANEL C2 ----------- —_ # CONTROL PANEL FANS _ ____ NORMALLY OPEN SPARE FIRE R SPA_RE CONTACTS USED WHEN FIRE FAN- 01 EXH-1 SYSTEM DRY SYSTEM DISCHARGES TO DISABLE Load Wiring 1 ——LOAD LEG I————————— — —0% FLA25 EQUIPMENT OR PROVIDE SIGNALS. 12 — LOAD LEG 2————_———— —_—0 10 HP Ism CONTACT (NOT FOR BUILDING FIRE ALARM .� .. ST-1 VMT-460 v WIRE DIRECT —Ll IG-3———————— ———0'0 TO ITHE MANSULBEALARM DI DIRECTLY ATING TO STARTER ——— ———————— ——11' SWITCH LOCATED IN ANSUL AUTOMAN 'B WIRE TO BMS SWITCH , DISCONNECT CONTROL PANEL 1 —————————————— — C�C101 k SWITCH EXTERNAL I�1 WILLA ACTIVATE ZONEIGFANSSAND J SWITCH LIGHTS CONTROL PANEL TO ACCESSORY ITEMS Responsibility, Electrician 16 CONTROL PANEL COMPONENT MICROSWITCH 1 n CONTROL PANEL 4-NO 6PP TO ( 1 --------- LC 4-NC, FIRE SYSTEM _ _____ __——— MICROSWITCH WIRE CI TO COMMON (1) WIRE ARI TO NORMALLY CLOSED (2). CI TO ARI SHOULD HAVE MS-1 4,NO � 19 CONTINUITY WHEN ARMED.———— LC INC IF MORE THAN ONE r MS-2J FIRE SYSTEM, WIRE 4 N0��� 20 IN SERIES AS SHOWN L AI -------- ----J 21 CONTROL PANEL ALL SWITCHES FACTORY WIRED 22 TO `14 CAT-5 CONNECTION SWITCHES 23 24 A B C D E F G H I FACTORY WIRING UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG, ALL FACTORY DC WIRING 18 AWG. PUT END OF LINE PLUG IN MOTOR POWER CIRCUIT SCHEMATIC SWITCHES EMPTY RJ45 JACKS, PN, EOL120A CIRCUIT BOARDS 1 J9 12OV Mi CAT-5 CABLE. LENGTH AS REQUIRED. ECPM03 Rev. 1.35 z nHM 1 HMI Rev. 1.06 N 1 WH 2x __ CONTROL INPUT I J4 ECPM03 14 AW BK LIT Tl OL-1 T1 CDNT-1 OH K05D10 BK _ 120V H1=LINE, 3 PH �J 1 - TI 2 �T2 OVLD,193-KB25 EA--& RIZ& 460 V �„�.,r � �b FLA.2.5 120 VAC 24 VDC 3 BK __ N1=NEUTRAL, 15A 15 A �BK X31 T `X�-0T3 HP,1.500 RELAY RELAY BREAKER, DO 24V ®OO %G(D ® NOT CONNECT 3 NC 2 1 12 NC 2 K © HK TO SHUNT TRIP - + DC J6 100®0© 7 COIL 8 7 1 A2 COIL 6 __ BREAKER. SEE PS-o1 DC COM[H 5 11 COM INSTALLATI❑N i N L AC BK _ SCHEMATIC FOR - + A ADDITIONAL REQ. A o I'CMP❑NEN F O 8 LONST PANEL LID II GR __ Z Z= ST-X FN varies ��_ z DL-X Overload PN:varies 3 C-x Contactor PN varies PS-1 Power Sup 24VDC PN MDPIB-24A-1C RA-x 120V Relay DPDT PN:34.110.0184,0 RD-x 24VDC Light Relay PN:34.110 0188.0 4 J7 120V 1 1 HK BK R F6�H1 BK HOODGHTS,l 1`--J PER�'N1 5 3 HK 011 -1 ST-1 SF ❑V HK 98, O -1 6 A N1 H1 AR1 H� RA-1 �aNl DC+ Bim®RD-1 R01 - LEGEND ——FIELD WIRING FACTORY WIRING BK- BLACK YW- YELLOW 7 BL- BLUE GY- GREY BR- BROWN PR- PURPLE OR- ORANGE RD- RED WH- WHITE OR/BL- OR/BL STRIPE BL/RD- BL/RD STRIPE RD/GN- RD/GN STRIPE WN/BL- WH/BL STRIPE 8 JOB NAME EMBASSY SUITES e... DRAWING TITLE DRY CONTACTS (SHOWN DE-ENERGIZED) SC-310110FP 14 AWGDESCRIPTION OF OPERATION RA-1-1 3 Phase w/ control for ON/OFF 1 ExhaustFan, Exhaust CW WITH FIRE on In Fire, Lights out In C YW Fire, Fan(s) On/Off Thermostatically ontrolled, Room 9 temperature sensor shipped loose for field Installation. O JOB NO DRAWN BY 381140 TYPE DATE FACTnRy 11/16/2015 14 x 18 x 6 Box DWG NO ECP #1-2