Loading...
PFI2015-00191 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PF12015-00191 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 12/22/2015 Parcel: SEG1629, 1632, 1677 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Comcast Project Description: Adjacent to 10850 SW McDonald St Comcast proposes to overlash 1,055'of new 48ct fiber optic cable to existing strand and construct 31'of.25 EHS strand and lashed 48ct fiber optic cable. Owner: FEES Description Date Amount PHONE: Contractor: PHONE: FAX- Applicant: SCOTT SARBER 11308 SW 68TH PKWY TIGARD, OR 97223 PHONE: 503-596-3819 Total $0.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: Not Present Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF1201"0191 Tv pe: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes,etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan A copy of the approved traffic control plan shall be readily available at the work area.Traffic control devices,flag persons,etc.,shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services:503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service Obtain City approval of any access closures. PFI_Utilities 09-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a m.to 7,00 p.m Mon-Fri unless otherwise authorized by the City. PFI_Utilities 10-TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 11 -TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety PFI_Utilities 12-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987 If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 13-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense Changes must be approved by the City in advance of work Applicant shall coordinate the work with affected utility agencies PFI_Utilities 14-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift Obtain advance approval of patching method No trench shall be left at any time in an un-safe condition Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work PFI_Utilities 15-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads,ditches,etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 16-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 17-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection,and after completing work covered by the permit PFI_Utilities 18-PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 19-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 20-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing,of any/all assignment changes. PFI_Utilities 21 -OTHER Applied Notice City of Tigard PUBLIC WORKS—ENGINEERING Public Facility Improvement (PFI) Permit DESCRIPTION OF WORK(in the right-of-way) REQUIRED SUBMITTAL Check one: N Utilities ❑ Sidewalk/driveway approach ❑ Street improvements ELEMENTS Detailed description: Comcast proposes to overlash 1,055'of new Fl Minor work in right-of-way (sidewalk repair,curb cut,street 48et fiber optic cable to existing strand and construct 31'of.25 EHS opening,etc.)requires: strand and lashed 48ct fiber optic cable. •application form,completed and signed •Submit one(1)copy of scaled sketch Property address/location(s): 10580 SW McDonald St.Tigard,OR 97224 of the proposed work to be done •Submit one(1)copy of traffic control plan —OR— Applicant's name: Comcast; Attn: Scott Sarber ❑ Substantial project work requires above items and professional Address: 11308 SW 68th Parkway engineered plans for: Zi , City/state: Tigard, OR 97223 •Street widening Zip: •Subdivision infrastructure Phone: (503) 596-3819 Email: Scott_Sarber@cable.comcast.com •Main utility line extension: - Storm Drain,Sanitary—Tigard Water—Tigard Water Service Contractor's name: Texstar Enterprises Area(includes Durham,King City CCB#: 178798 Expiration: 10/10/2017 and a portion of unincorporated Address: 14122 Arndt Rd Washington County) City/state: Aurora, OR 97002 DELIVER APPLICATION TO: '"/.ih: Phone: (503) 793-3109 1 ;mail: Jimminer@texstarenterprises.com City of Tigard Planning/Engineering 13125 SW Hall Blvd. Engineer's name: Jack Nygard Tigard,OR 97223 6566 SE Lake Rd applications for"minor work in right-of-way" Address: only may be emailed to: City/state: Milwaukie, OR Zip: 97222 EQ ermits(g>a^Torgov Phone: (503)650-6041 Ext.203 Email: Jack_Nygard@kbmail.net Case No.:�Tl-�U�S= 00/ / Estimated value of work (within the public right-of-way): $1,200.00 Application submitral fee: Is work related to a LAND-USE DECISION? ❑ Yes p No Application accepted: If so,please specify(MLP,SDR,SUB,etc.) case #: By: L--S Darer Is work related to a BUILDING PERMIT? ❑ Yes .❑ No APP licatio re wed: By: Date: If so,please specify(BUILDING PERMIT)case#: Applicant otified: A(e /`v /YDS I�� Ll�v' irk— s 3 — (G�+'^- By: Date: a �� C,7 l:%CURVLMVAaAi&n%Lnnd Use Applications Rev,07/16/2014 City of Tigard 13125 SW Hall Blvd. Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 4 w R APPLICANTS NOTE: Person specified as`Applicant"shall be designated"Permittee"and shall provide financial assurance for work. *when the owner and the applicant are different people,the applicant must be the puichaset of record ora lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written authorisation with this application. BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY THAT: • The above request does not violate any deed restrictions that may be attached to or imposed upon the subject perr<. • If the application is granted,the applicant will exercise the rights granted in accordance xvith the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in the plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. SIGNATURES of each owner of the subject property required. ,,i rd Jack Nygard 12/15/15 Applicant/ orized Agent's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT Cityof Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • \v%v\v tigard-or.gov 503-718-2421 • Page 2 of 4 ci o ZD \ 2 Di � Z> OZm \ : T O'0 oO o �m? \ nN FA p C N y O DMZ opo —__— '33'� Iv �_--3AV H180L MS i q nyp o mu a I Zf/1 p 2 :@ oZ : a 90 0 $ - j - -- - SW 104TH AVE 105 N 10375 r y 10375 > 10362 I U 10345 j I, 10342 j --- --_ i10345 � I 1 9 10315 : I i a I10330 ------J � i 10290 i 10315 10285 � L i j = 10255 10255 _ r- << m I� _ I I g N C j 10225 g�, I QLSfF C12 °'nCm ,4150 OA (Gn 3AV OWN MS oW OT Z 14154 O- 458ZDm ZAmDNN00 I� 10195I �m ppZm ZOp DNi NO3C OD mm' cOi� x�^ 3 Z o M y Z 00;D >m Opo �y r . .. _ 0z yon mm $m r j Otnp Op mm - 10160 maz Cm 0 r N p 10100 Q A 10105 10165 p 70 £ I 3T vsrs cevc er�eereowxsau arvs 10580 SWMCDONAIDST. N CCO mcast ° TIGARD,OR 97724 7ECMNIGM saimoRs F _Contact:Scott Sarber Po BO%2529.Gaatli—,,OR 97015 46177 Phone:(503)596-3819 0�.150316506041 Ext.216CITY OF TIGARD Scott Sarber@cable.comcast.com E-11:GlenWllll—@kbmA-t - ROW PERMIT DRAWING Page 80 2011 Edition 5.3 Two-Lane, Two-Way Roads Shoulder Work w/ Minor Road Encroachment Diag. 300) Use this detail for non-freeway work which extends into a travel lane and maintains a minimum 10 foot travel lane. If a minimum 10 foot travel lane can not be maintained, or when traffic can not safely pass by in both lanes simultaneously, use the appropriate lane closure diagrams—for example, Diagrams 310 through 350. A lane closure may be appropriate for conditions such as high traffic volumes, high speeds, and inadequate approach sight distance to the work space, or heavy equipment adjacent to the travel lane. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4 3—Lights and Lighted Signs for exceptions. 2 For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Cones shall be placed along the entire length of the work space If a protection vehicle is used and work is in place one hour or less, the taper and tangent devices may be omitted. 4. If the speed is 45 mph or higher, volumes exceed 2000 ADT, or there is limited sight distance, consider placing cones or tubular markers on centerline. 5. An arrow board in caution mode or truck-mounted PCMS with "SHOULDER WORK" or other appropriate message may be used for higher visibility. Sign Spacing and Buffer Lengths(feet) Posted Spacing Between Signs Buffer Speed A B C Space 20 50 25 100 100 100 75 30 100 35 40 350 350 350 125 150 45 180 50 500 500 500 210 55 250 Chapter 5 December 2011 2011 Edition Page 81 Shoulder Work w/ Minor Road Encroachment Dia g 03 ROAD A°�> l T� Initial Warning A • Sign • • • (Optional) • • Protection Vehicle • w/TMA(both Optional) See Chapter 4 . Buffer • 10' • minimum • 1-13 • • A ROAD M NARROWS (Optional) B 1 1 % ROAD WORK AHEAD Initial Warning Sign December 2011 Chapter 5 f Page 84 2011 Edition Stationary Lane Closure with Flagging Diagram 0011 Diagram 320 covers total closure of one lane of a two-lane, two-way roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles See Section 4 3—Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340—Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4) should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the"Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The"ONE LANE ROAD AHEAD"(W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. Chapter 5 December 2011 CD ---- - N No CD N Single Flagger Operation isL--i- ; I for Low Volumes "Aa I (Optionao o aa (ADT<400)4.1 BE; nwooE" c I PREPARED O ROS E CU 'a 1• H H 2• I TO STOP ��AHEAD r 0 0 0 N — — — — — — I • ROAD m ' —► r•®, ♦ I WORK KOK8K9KA I- J I AHEAD n � W N .Sn° I C (A W _ m amv I 0000(nONO • A B B C I------------------------ 3 1 mile I -n f max. >y • • FRO ® •• B B A Buffer Protection Vehicle ROAD • w/TMA(both Optional) WORK See Chapter 4 _0 AHEAD BE ONE LANE PREPARED ROAD TO STOP Two Flagger Operation 3 AHEAD N m m 0D 01 (Optional) p cn