Loading...
Specifications (2) t 0 , I / s.t),(.)1 J Do l (,-- I S2 3 U S ww"v r r5 (/Y Zw_} MICHAEL K. BROWN, S.E. 5346 E. Branchwood Dr., Boise, ID 83716 SEP 7 2015 811) 208-850-7542, mikebrown.se@gmail.com an ARD BUILDING NG DI GENERIC RETIANING WALL WITHOUT KEY STRUCTURAL DESIGN CALCULATIONS (LONG HEEL) ENGR. JOB # DM12-069.01 OriRg0,4* ,GIN(,..�f.� - ':ece "P -,-: .ORE •;'f a o1` tio 4-7Ncs\- i EXPIRATION GATE: 12—.51 —15 Prepared for: StoneBridge Homes, NW, LLC Date: 08-27-14 : , R " /-A-/ (2) # 4 CONT. MIN cr TOW. Ru c r u-k 5 ;:- T \ l /��\\-„,------------- ,r r� N ,p/, •.. 11-1 11=111-1 , -� 1 ' y r r ''...t:'. - 11-11 I-111=111-1 I 1a z = ';‘\1\-<" t : l1v r / z . - 11- ------11F--111=-111=-11 I -- , _ o II-1 I I—IIIIII-1 I I y y �, � ,„. ,r 7-4.14— .= 11=111=-11 - �,, 10, + 111—III K/N G S\-r '. 1 i'+t—.1s-- EXPIRATION DATE. 1 2-31—1 5 • _sfa� 1-/' "H”BARS •' ..T--oT�.Y.iY •: : •:: Y • : 1 1/2"CL•.1.I 12"WIDE(MIN) DRAIN ROCK UP TO = i `.. ; �Y .Y .Y . 12"FROM T.O.W. DRAIN PIPE AT BOTTOM "''""'' ' "V"BAR DOWELS ,�T�T•. iir _ �."�� "F"BARS G3' _I w .... 's - .'li� • Ll..1 J . .. - ..�..� _ _ �i��iT• "r LI) w ¢ = =1=I- X BARS - "r•"; - % a!\, . '_ Ili. • .: .n. 'q: ,q• •1 .w. 311_ .4 • 4"• irtiY�:YeiYeGTeireieriYsiY�iY�i'"�6�i"siY6i1 CLR TYP. ``- .9...... 1 1 COMPACTED GRAVEL #4 CONT.TYP A—B / / W Cantilevered Retaining Wall Schedule Generic Retaining Wall For Standard Practice Values H(Ft) W A B D "V"Bars "H"Bars "F"Bars "X"Bars rap Length r Dowel Hegilh DH 5'-0" 4'-3" 8" 0" 1'-0" #5@18"o.c. #5@18"o.c. #5@18"o.c. #5@18"o.c. 6-0" 5'-0" 0'-8" 0'-3" 1'-0" #5@14" #5@14" #5@14" #5@14" 7'-0" 6-0" 0'-8" 0'-6" 1'-0" #5@8"o.c. #5@12"o c. #5@12"o.c. #5@12"o.c. 8'-0" 6-9" 0'-8" 0'-9" 12 #5@t0'oc. #5@t2"o.c. #5@12"o.c. #5@12"o.c. 2'-8" 39" 9'-0" 8'-0" 0'-10" 1-3" 1'-0" #5@10'o.c. #5@12"o.c. #5@12'o.c. #5@12"o.c. 2'-8" 39" 10'-0" 8'-9" 0'-10" 1'-6" 1'-2" #5@7.5"o.c #5@tr'o.c. #5@12"o.c. #5@12"o.c. 2•-8" 39" Notes: 1. Design values are based on Standard Practice Values: 2. Allowable Soil Bearing=1,500 psf.Passive=250 psf/ft,Friction=.4,E.F.P.=40 psf/It 3. Footing and Wall F'c=2,500 psf @ 28 days.Fy=60 ksi 4. Geotech to verity by site observation and sign off on retaining wall design assumptions prior to concrete pour as per soils report and jurisdictional requirements. Geotech site visit reports to be copied to Core Engineering. 5. If no"T"bars are shown and no dimension is shown in the table above for Dowel Height DH,extend the"V"bar dowel from the looting to the top of the wall. ) CANTILEVERED RETAINING WALL 7 SCALE: N.T.S. Use menu item Settings> Printing&Title Block Title : 5'-0"Wall Page: to set these five lines of information Job# - Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 5'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Criteria 1 [Soil Data Retained Height = 5.00 ft Allow Soil Bearing = 1,500.0 psf ' ` ` " - � Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method -'4' Heel Active Pressure = 35.0 psf/ft . 4 •. Slope Behind Wall = 0.00: 1 = . : a?'! Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft • Water height over heel = 0.0 ft Soil Density,Heel = 110.00 pcf .. :. Soil Density,Toe = 110.00 pcf FootingiiSoil Friction = 0.350 :i i, ."' ':- = ,. a i{ ..i•;'" ''`x ` Y �;4 " Soil height to ignore for passive pressure = 12.00 in "t Fu-r i. '1:-::-• ..:: ... .- fi C....;“.•!..,,. .. . LSurcharge Loads ILateral Load Applied to Stem ` Adjacent Footing Load Surcharge Over Heel = 40.0 psf Lateral Load = 0.0#!ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf "".Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft Axial Load Applied to Stem has been increased 1.00 Footing Type by a factor of Base Above/Below Soil Axial Dead Load = 0.0 lbs Wind on Exposed Stem= 0.0 psf at Back of Wall = 0.0 ft Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in _Design Summary I Stem Construction 1 Top Stem Stem OK Wall Stability Ratios Design Height Above Ftg ft= 0.00 Overturning = 4.52 OK Wall Material Above"Ht" = Concrete Sliding = 1.64 OK • Thickness = 8.00 Rebar Size = # 5 Total Bearing Load = 3,302 lbs Rebar Spacing = 18.00 ...resultant ecc. = 6.43 in Rebar Placed at = Center Design Data Soil Pressure @ Toe = 1,365 psf OK fb/FB+fa/Fa = 0.407 Soil Pressure @ Heel = 189 psf OK Total Force @ Section lbs= 801.8 Allowable = 1,500 psf Moment....Actual ft-#= 1,421.2 Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,638 psf Moment Allowable = 3,493.2 ACI Factored @ Heel = 227 psf Shear Actual psi= 16.7 Footing Shear @ Toe = 0.0 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 28.4 psi OK Wall Weight = 100.0 Allowable = 75.0 psi Rebar Depth 'd' in= 4.00 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 12.00 LAP SPLICE IF BELOW in= Lateral Sliding Force = 706.4 lbs HOOK EMBED INTO FTG in= 6.00 less 100%0Passive Force= - 0.0 lbs Lap splice above base reduced by stress ratio less 100%Friction Force = - 1,155.6 lbs Hook embedment reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data ....for 1.5: 1 Stability = 0.0 lbs OK fm psi= Fs psi= Solid Grouting = Use Half Stresses = Modular Ratio'n' Load Factors Building Code IBC 2009,AC1 Short Term Factor = Dead Load 1.200 Equiv.Solid Thick. _ Live Load 1.600 Masonry Block Type = Medium Weight Earth, H 1.600 Masonry Design Method = ASD Concrete Data - -- - -- Wind,W 1.600 fc psi= 2,500.0 Seismic, E 1.000 Fy psi= 60,000.0 Use menu item Settings>Printing&Title Block Title : 5'-0"Wall Page: to set these five lines of information Job# Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 5'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING Footing Dimensions & Strengths I IL Footing Design Results Toe Width = 0.00 ft Toe Heel Heel Width = 4.25 Factored Pressure = 1,638 227 psf Total Footing Width = 4.25 Mu':Upward = 0 0 ft-# Footing Thickness = 12.00 in Mu':Downward = 0 411 ft-# Mu: Design = 0 411 ft-# Key Width = 0.00 in Actual 1-Way Shear = 0.00 28.42 psi Key Depth = 0.00 in Allow 1-Way Shear = 0.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #4 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #4 @ 18.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd,Mu<S'Fr Heel:Not req'd,Mu<S*Fr Key: No key defined _Summary of Overturning & Resisting Forces& Moments OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 630.0 2.00 1,260.0 Soil Over Heel = 1,970.8 2.46 4,845.0 Surcharge over Heel = 76.4 3.00 229.1 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 143.3 2.46 352.4 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= *Axial Live Load on Stem = = Soil Over Toe = 1,970.8 Surcharge Over Toe = Total 706.4 O.T.M. 1,489.1 Stem Weight(s) = 550.0 0.33 183.3 Earth @ Stem Transitions= = = Footing Weight = 637.5 2.13 1,354.7 Resisting/Overturning Ratio = 4.52 Key Weight = Vertical Loads used for Soil Pressure= 3,301.7 lbs Vert.Component - Total= 3,301.7 lbs R.M.= 6,735.3 *Axial live load NOT included in total displayed or used for overturning resistance,but is included for soil pressure calculation. DESIGNER NOTES: Use menu item Settings>Printing&Title Block Title : 5'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 5'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING Criteria I LSoil Data ,,- , Retained Height = 5.00 ft Allow Soil Bearing = 1,995.0 psf . , ••: Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method r .. .'4,,.;-'--; ,.' Heel Active Pressure 35.0 psf/ft wia Slope Behind Wall = 0.00: 1 = = Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft ,`:�_,., '�<'`;'.rs .: :s"'i'"- t s *1 9 n ,T Water height over heel = 0.0 ft Soil Density, Heel = 110.00 pcf ^ ; 7 4•i 1 n3 � r 1 Soil Density,Toe = 110.00 pcf , a lr-`4-;';',1�.)�' 'W ,•, FootingljSoil Friction = 0.350 ,, ' , f wt 0-{ Soil height to ignore - R s sfi "" for assive pressure = 12.00 in `tt ° " s ` ;fir �� Surcharge Loads 9 Lateral Load Applied to Stem 9 Adjacent Footing Load 9 Surcharge Over Heel = 40.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft Axial Load Applied to Stem has been increased by a factor of 1.00 Footing Type pp Base Above/Below Soil = 0.0 ft Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Earth Pressure Seismic Load 9 Kae for seismic earth pressure = 0.389 Added seismic base force 157.6 lbs Design Kh = 0.166 g Ka for static earth pressure = 0.277 Difference: Kae-Ka = 0.112 Using Mononobe-Okabe/Seed-Whitman procedure Stem Weight Seismic Load 9 FP/WP Weight Multiplier = 0.400 g Added seismic base force 157.1 lbs Use menu item Settings>Printing&Title Block Title : 5'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 5'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Design Summary ! [Stem Construction 1 Top Stem Stem OK Wall Stability Ratios Design Height Above Ftc ft= 0.00 Overturning = 2.55 OK Wall Material Above"Ht" = Concrete Sliding = 1.13 Ratio<1.5! Thickness = 8.00 Rebar Size = # 5 Total Bearing Load = 3,302 lbs Rebar Spacing = 18.00 ...resultant ecc. = 10.64 in Rebar Placed at = Center Design Data - Soil Pressure @ Toe = 1,777 psf OK fb/FB+fa/Fa = 0.712 Soil Pressure @ Heel = 0 psf OK Total Force @ Section lbs= 1,175.9 Allowable = 1,995 psf Moment....Actual ft-#= 2,488.6 Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,132 psf Moment Allowable = 3,493.2 ACI Factored @ Heel = 0 psf Shear Actual psi= 21.3 Footing Shear @ Toe = 0.0 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 28.4 psi OK Wall Weight = 100.0 Allowable = 75.0 psi Rebar Depth 'd' in= 4.00 LAP SPLICE IF ABOVE in= 16.67 Sliding Calcs (Vertical Component Used) LAP SPLICE IF BELOW in= Lateral Sliding Force = 1,021.1 lbs HOOK EMBED INTO FTG in= 6.00 less 100%Passive Force= - 0.0 lbs Lap splice above base reduced by stress ratio less 100%Friction Force = - 1,155.6 lbs Hook embedment reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data ....for 1.5: 1 Stability = 376.1 lbs NG fm psi= Fs psi= Solid Grouting = Use Half Stresses = Modular Ratio'n' = Load Factors Building Code IBC 2009,ACI Short Term Factor = Dead Load 1.200 Equiv.Solid Thick. = Live Load 1.600 Masonry Block Type = Medium Weight Earth,H 1.600 Masonry Design Method = ASD Wind,W 1.600 Concrete Data fc psi= 2,500.0 Seismic,E 1.000 Fy psi= 60,000.0 Footing Dimensions & Strengths ! Footing Design Results Toe Width = 0.00 ft Toe Heel Heel Width = 4.25 Factored Pressure = 2,132 0 psf Total Footing Width = 4.25 Mu':Upward = 0 0 ft-# Footing Thickness = 12.00 in Mu':Downward = 0 411 ft-# Mu: Design = 0 411 ft-# Key Width = 0.00 in Actual 1-Way Shear = 0.00 28.42 psi Key Depth = 0.00 in Allow 1-Way Shear = 0.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #4 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #4 @ 18.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd,Mu<S*Fr Heel:Not req'd,Mu<S*Fr Key: No key defined Use menu item Settings>Printing&Title Block Title : 5'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 5'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\bl RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING Summary of Overturning & Resisting Forces& Moments OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft 04 lbs ft 04 Heel Active Pressure = 630.0 2.00 1,260.0 Soil Over Heel = 1,970.8 2.46 4,845.0 Surcharge over Heel = 76.4 3.00 229.1 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 143.3 2.46 352.4 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= 'Axial Live Load on Stem = Seismic Earth Load = 157.6 3.60 567.3 Soil Over Toe = 1,970.8 Seismic Stem Self Wt = 220.0 3.75 825.0 Surcharge Over Toe = Total 1,021.1 O.T.M. 2,645.7 Stern Weight(s) = 550.0 0.33 183.3 Earth @ Stem Transitions= = = Footing Weight = 637.5 2.13 1,354.7 Resisting/Overturning Ratio = 2.55 Key Weight = Vertical Loads used for Soil Pressure= 3,301.7 lbs Vert.Component = Total= 3,301.7 lbs R.M.= 6,735.3 If seismic included the min.OTM and sliding 'Axial live load NOT included in total displayed,or used for overturning ratios may be 1.1 per IBC'09, 1807.2.3. resistance,but is included for soil pressure calculation. DESIGNER NOTES: Use menu item Settings> Printing&Title Block Title : 6'-0"Wall Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 6'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Criteria 9 Soil Data _'9 {.,,:;„ : �SaL 3 Retained Height = 6.00 ft Allow Soil Bearing = 1,500.0 psf 1,;,,, ,v ;93 } ;3 ,,�,,:,`, Equivalent Fluid Pressure Method f' ==;•. Wall height above soil = 0.50 ft :?•� s -; Heel Active Pressure = 35.0 psf/ft Slope Behind Wall = 0.00: 1 = •, Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft Water height over heel = 0.0 ft Soil Density,Heel = 11 '' g ty, 0.00 pcf :,:.' .:--ut^::r":�zi,aa,f}.•�z,•:f Soil Density,Toe = 110.00 pcf '-.z.0 t�i a`:; X91�•e Y . ;. FootinglISoil Friction = 0.350 " 'w}.; 1; t,- .;4c , ,u = t� -,-=• Soil height to ignore . ,• t ,. for passive pressure = 12.00 in Et?�f' t:� Surcharge Loads I Lateral Load Applied to Stem I Adjacent Footing Load Surcharge Over Heel = 40.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft 9 has been increased 1.00 Footing Type Axial Load Applied to Stem by a factor of Base Above/Below Soil 0.0 ft Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Design Summary 9 [Stem Construction 9 Top Stem Stem OK Wall Stability Ratios Design Height Above Ftc it= 0.00 Overturning = 4.63 OK Wall Material Above"Ht" = Concrete Sliding = 1.57 OK Thickness = 8.00 Rebar Size = # 5 Total Bearing Load = 4,258 lbs Rebar Spacing = 14.00 ...resultant ecc. = 6.34 in Rebar Placed at = Center Soil Pressure @ Toe = 1,391 psf OK Design Data Soil Pressure @ Heel = 312 psf OK /FB+fa/Fa = 0.541 Allowable = 1,500 Total Force @ Section lbs= 1,130.2 psf Moment....Actual ft-#= 2,382.5 Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,670 psf Moment Allowable = 4,407.9 ACI Factored @ Heel = 374 psf Shear Actual psi= 23.5 Footing Shear @ Toe = 0.0 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 37.1 psi OK Wall Weight = 100.0 Allowable = 75.0 psi Rebar Depth 'd' in= 4.00 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 12.65 LAP SPLICE IF BELOW in= Lateral Sliding Force = 946.6 lbs HOOK EMBED INTO FTG in= 6.00 less 100%Passive Force= - 0.0 lbs Lap splice above base reduced by stress ratio less 100%Friction Force = - 1,490.4 lbs Added Force Req'd = 0.0 lbs OK Masonry Data Hook embedment reduced by stress ratio ....for 1.5: 1 Stability = 0.0 lbs OK fm psi= Fs psi= Solid Grouting = Use Half Stresses = - Modular Ratio'n' = Load Factors Building Code IBC 2009,ACI Short Term Factor = Dead Load 1.200 Equiv.Solid Thick. = Live Load 1.600 Masonry Block Type = Medium Weight Masonry Design Method = ASD Earth,H 1.600 _ Wind,W 1.600 Concrete Data -- - ---- fc psi= 2,500.0 Seismic, E 1.000 Fy psi= 60,000.0 Use menu item Settings>Printing&Title Block Title : 6'-0"Wall Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 6'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING Footing Dimensions & Strengths I [ Footing Design Results ,I Toe Width = 0.25 ft Toe Heel Heel Width = 4.75 Factored Pressure = 1,670 374 psf Total Footing Width = 5.00 Mu':Upward = 51 0 ft-# Footing Thickness = 12.00 in Mu':Downward = 6 534 ft-# Mu: Design = 46 534 ft-# Key Width = 0.00 in Actual 1-Way Shear = 0.00 37.11 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #4 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #4 @ 18.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd,Mu<S*Fr Heel: Not req'd,Mu<S*Fr Key: No key defined _Summary of Overturning & Resisting Forces & Moments OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 857.5 2.33 2,000.8 Soil Over Heel = 2,695.0 2.96 7,972.7 Surcharge over Heel = 89.1 3.50 311.8 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 163.3 2.96 483.2 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= *Axial Live Load on Stem = = Soil Over Toe = 2,695.0 Surcharge Over Toe = Total 946.6 O.T.M. 2 312,7 Stem Weight(s) = 650.0 0.58 379.2 Earth @ Stem Transitions= = = Footing Weight = 750.0 2.50 1,875.0 Resisting/Overturning Ratio = 4.63 Key Weight = Vertical Loads used for Soil Pressure= 4,258.3 lbs Vert.Component = Total= 4,258.3 lbs R.M.= 10,710.1 Axial live load NOT included in total displayed,or used for overturning resistance,but is included for soil pressure calculation. DESIGNER NOTES: Use menu item Settings> Printing&Title Block Title : 6'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 6'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro iD (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING Criteria .: Soil Data Retained Height = 6.00 ft Allow Soil Bearing = 1,995.0 psf _ ;x- y Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method 'i c Heel Active Pressure = 35.0 psf/ft Slope Behind Wall = 0.00: 1 = '.,"%f4,..R':- ;;` A %;a'.7'!„'... Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft t '” 1+-/f;:,'..-1,,,,',, t : rte" Water height over heel = 0.0 ft Soil Density,Heel = 110.00 pcf ,, " fr tg , Soil Density,Toe = 110.00 pcf . j4� ? ' Footinglf Soil Friction = 0.350 a —/ Soil height to ignore , .> ,Vtt-h 4.1,,611-v r-141-0,,,..-v., for passive pressure = 12.00 in s:Aileii: Surcharge Loads Lateral Load Applied to Stem II Adjacent Footing Load Surcharge Over Heel = 40.0 psf = FootingLoad = 0.0 lbs Lateral Load 0.0#/ft Adjacent Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft has been increased 1.00 Axial Load Applied to Stem Footing Type —k by a factor of Base Above/Below Soil Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall = 0.0 ft Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Earth Pressure Seismic Load 1 Kae for seismic earth pressure = 0.389 Added seismic base force 214.5 lbs Design Kh = 0.166 g Ka for static earth pressure = 0.277 Difference: Kae-Ka = 0.112 Using Mononobe-Okabe/Seed-Whitman procedure Stem Weight Seismic Load 1 Fp/WP Weight Multiplier = 0.400 g Added seismic base force 185.7 lbs Use menu item Settings> Printing&Title Block Title : 6'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 6'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Design Summary A LStem Construction 1 Top Stem Stem OK Wall Stability Ratios Design Height Above Ft€ ft= 0.00 Overturning = 2.68 OK Wall Material Above"Ht" = Concrete Sliding = 1.11 Ratio<1.5! Thickness = 8.00 Rebar Size = # 5 Total Bearing Load = 4,258 lbs Rebar Spacing = 14.00 ...resultant ecc. = 11.10 in Rebar Placed at = Center Soil Pressure @ Toe = 1,802 psf OK Design Data Soil Pressure @ Heel = 0 psf OK Total T +fa/Fa = 0.913 Allowable = 1,995 psf Total Force @ Section lbs= 1,612.1 Soil Pressure Less Than Allowable Moment....Actual ft-#= 4,026.6 ACI Factored @ Toe = 2,163 psf Moment Allowable = 4,407.9 ACI Factored @ Heel = 0 psf Shear Actual psi= 29.0 Footing Shear @ Toe = 0.0 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 37.1 psi OK Wall Weight = 100.0 Allowable = 75.0 psi Rebar Depth 'd' in= 4.00 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 21.38 Lateral Sliding Force = 1,346.8 lbs LAP SPLICE IF BELOW in= less 100%Passive Force= - 0.0 lbs HOOK EMBED INTO FTG in= 7.39 less 100%Friction Force = - 1,490.4 lbs Lap splice above base reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data Hook embedment reduced by stress ratio ....for 1.5: 1 Stability = 529.8 lbs NG fm psi= Fs psi= Solid Grouting = Use Half Stresses = Modular Ration' = Load Factors Building Code IBC 2009,ACI Short Term Factor = Dead Load 1.200 Equiv.Solid Thick. = Live Load 1.600 Masonry Block Type = Medium Weight Masonry Design Method = ASD Earth,H 1.600 Concrete Data Wind,W 1.600 fc psi= 2,500.0 Seismic,E 1.000 Fy psi= 60,000.0 Footing Dimensions & Strengths 1 Footing Design Results Toe Width = 0.25 ft Toe Heel Heel Width = 4.75 Factored Pressure = 2,163 0 psf Total Footing Width = 5.00 Mu':Upward = 66 0 ft-# Footing Thickness = 12.00 in Mu':Downward = 6 534 ft-# Mu: Design = 61 534 ft-# Key Width = 0.00 in Actual 1-Way Shear = 0.00 37.11 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #4 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #4 @ 18.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd,Mu<S*Fr Heel:Not req'd,Mu<S*Fr Key: No key defined • Use menu item Settings>Printing&Title Block Title : 6'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 6'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,AC1 530-08 License To:CORE ENGINEERING _Summary of Overturning & Resisting Forces & Moments a OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 857.5 2.33 2,000.8 Soil Over Heel = 2,695.0 2.96 7,972.7 Surcharge over Heel = 89.1 3.50 311.8 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 163.3 2.96 483.2 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= •Axial Live Load on Stem = Seismic Earth Load = 214.5 4.20 900.8 Soil Over Toe = 2,695.0 Seismic Stem Self Wt = 260.0 4.25 1,105.0 Surcharge Over Toe = Total 1,346.8 O.T.M. 4,002.8 Stem Weight(s) = 650.0 0.58 379.2 Earth @ Stem Transitions= = = Footing Weight = 750.0 2.50 1,875.0 Resisting/Overturning Ratio = 2.68 Key Weight = Vertical Loads used for Soil Pressure= 4,258.3 lbs Vert.Component = Total= 4,258.3 lbs R.M.= 10,710.1 If seismic included the min.OTM and sliding 'Axial live load NOT included in total displayed,or used for overturning ratios may be 1.1 per IBC'09, 1807.2.3. resistance,but is included for soil pressure calculation. DESIGNER NOTES: Use menu item Settings>Printing&Title Block Title : 7'-0"Wall Page: to set these five lines of information Job# Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 7'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Criteria I1 Soil Data Retained Height = 7.00 ft Allow Soil Bearing = 1,500.0 psf .�* - xxt 1 a,',,. .1,, Equivalent Fluid Pressure Method ::-.1.,.• , Wall height above soil = 0.50 ft q - j ! <;l ''',-; `�"°'_li' •,i Heel Active Pressure - 35.0 psf/ft ,;,2,*,-,r',1-+c„ ,,_ �• ;;' Slope Behind Wall = 0.00: 1 = t r ,.4" '4 „`�' Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft :• r.x sari `ms`s u;; Water height over heel = 0.0 ft Soil Density,Heel = 110.00 pcf j,l<?%Y--'•, �3, ' ", -,,,.`;',‘"';.:;'-';.:Fti . .. < ,:j14,;:z.;' r -'1'za: +.,...�, Soil Density,Toe = 110.00 pcf r" r "s' . t r.p t'' `' t. Footin Soil Friction = 0.350 4 ' ,� „: ' '; Soil height to ignore i�S, �c !'P F, for passive pressure = 12.00 in ,$ ' Q x#stP.a r 't'^''- �;-£^� .��a:i»'€�t�wz`fSt% t>tl'>�a <s rao:. Surcharge Loads i LLateral Load Applied to Stem 1 Adjacent Footing Load Surcharge Over Heel = 40.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft Axial Load Applied to Stem has been increased 1.00 Footing Type pp by a factor of Base Above/Below Soil Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall = 0.0 ft Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Design Summary I Stem Construction 9 Top Stem Stem OK Wall Stability Ratios Design Height Above Ftc ft= 0.00 Overturning = 5.11 OK Wall Material Above"Ht" = Concrete Sliding = 1.59 OK Thickness = 8.00 Rebar Size = # 5 Total Bearing Load = 5,565 lbs Rebar Spacing = 8.00 ...resultant ecc. = 5.90 in Rebar Placed at = Center Design Data Soil Pressure @ Toe = 1,383 psf OK fb/FB+fa/Fa = 0.512 Soil Pressure @ Heel = 472 psf OK Total Force @ Section lbs= 1,514.5 Allowable = 1,500 psf Moment....Actual ft-#= 3,700.2 Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,660 psf Moment Allowable = 7,221.8 ACI Factored @ Heel = 566 psf Shear Actual psi= 31.6 Footing Shear @ Toe = 0.0 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 49.5 psi OK Wall Weight = 100.0 Allowable = 75.0 psi Rebar Depth 'd' in= 4.00 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 12.00 LAP SPLICE IF BELOW in= Lateral Sliding Force = 1,221.8 lbs HOOK EMBED INTO FTG in= 6.00 less 100%Passive Force= - 0.0 lbs Lap splice above base reduced by stress ratio less 100%Friction Force = - 1,947.8 lbs Hook embedment reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data - ....for 1.5: 1 Stability = 0.0 lbs OK fm psi= Fs psi= Solid Grouting = Use Half Stresses = Modular Ration' = Load Factors - Short Term Factor = Building Code IBC 2009,ACI Dead Load 1 200 Equiv. Solid Thick. = Live Load 1.600 Masonry Block Type = Medium Weight Earth,H 1.600 Masonry Design Method = ASD Concrete Data Wi - -- --- - nd,W 1.600 fc psi= 2,500.0 Seismic, E 1.000 Fy psi= 60,000.0 Use menu item Settings> Printing&Title Block Title : 7'-0"Wall Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 7'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Footing Dimensions & Strengths 8 Footing Design Results Toe Width = 0.50 ft Toe Heel Heel VVidth = 5.50 Factored Pressure = 1,660 566 psf Total Footing Width = 6.00 Mu':Upward = 204 0 ft-# Footing Thickness = 12.00 in Mu':Downward = 23 748 ft-# Mu: Design = 181 748 ft-# Key Width = 0.00 in Actual 1-Way Shear = 0.00 49.52 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #4 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #4 @ 18.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes& Spacings Cover @ Top 2.00 @ Btm= 3.00 in Toe: Not req'd,Mu<S'Fr Heel:Not req'd,Mu<S*Fr Key: No key defined Summary of Overturning & Resisting Forces & MomentsII 1 OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 1,120.0 2.67 2,986.7 Soil Over Heel = 3,721.7 3.58 13,336.0 Surcharge over Heel = 101.8 4.00 407.3 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 193.3 3.58 692.8 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= *Axial Live Load on Stem = = Soil Over Toe = 3,721.7 Surcharge Over Toe = Total 1,221.8 O.T.M. 3,393.9 Stem Weight(s) = 750.0 0.83 625.0 Earth @ Stem Transitions= = = Footing Weight = 900.0 3.00 2,700.0 Resisting/Overturning Ratio = 5.11 Key Weight = Vertical Loads used for Soil Pressure= 5,565.0 lbs Vert.Component = Total= 5,565.0 lbs R.M.= 17,353.8 *Axial live load NOT included in total displayed,or used for overturning resistance,but is included for soil pressure calculation. DESIGNER NOTES: Use menu item Settings>Printing&Title Block Title . 7'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 7'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING Criteria b [Soil Data I 3 ,, ti;. spa ;°- Allow Soil Bearing = 1,995.0 psf , , Retained Height = 7.00 ft 9 P .xs. , 1 i� .- Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method - _`.--,, ._ tr,•f�.,,.-:-.1.,-,...,.`;. • Heel Active Pressure = 35.0 psf/ft � � .:.,:r,47',,_ ,- � � Slope Behind Wall = 0.00. 1 = P • .,&1-.-_ `={' is t.t;F} # . c , { �� r ' ler- Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft ;' 7.:-.,,,A`'''4 ` "x_,a 4,, ,-. t ` Water height over heel = 0.0 ft Soil Density,Heel = 110.00 pcf j 1"t"4.f:' fi'yt'4:, -c Soil Density,Toe = 110.00 pcf �_, i ; � ,4e t . r1 ,,,O,T FootingilSoil Friction = 0.350 grid' `0 ,tii"r;$x;tet .: Soil height to ignore x �s 1 ���r' w for passive pressure = 12.00 in r.y, ,4,:,:•:,:..-,-.,,,,,„-•,. ..s`, i Surcharge Loads Lateral Load Applied to Stem 1 Adjacent Footing Load Surcharge Over Heel = 40.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft l has been increased 1.00 Footing Type Axial Load Applied to Stem 9 by a factor of Base Above/Below Soil Axial Dead Load = 0.0 lbs = 0.0 ft Wind on Exposed Stem = 0.0 psf at Back of Wall Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Earth Pressure Seismic Load 0 Kae for seismic earth pressure = 0.389 Added seismic base force 280.1 lbs Design Kh = 0.166 g Ka for static earth pressure = 0.277 Difference: Kae-Ka = 0.112 Using Mononobe-Okabe/Seed-Whitman procedure Stem Weight Seismic Load 0 Fp/WP Weight Multiplier = 0.400 g Added seismic base force 214.3 lbs Use menu item Settings>Printing&Title Block Title : 7'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 7'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Design Summary Stem Construction I Top Stem Stem OK Wall Stability Ratios Design Height Above Ftc ft= 0.00 Overturning = 3.01 OK Wall Material Above"Ht" = Concrete Sliding = 1.13 Ratio< 1.5! Thickness = 8.00 Rebar Size = # 5 Total Bearing Load = 5,565 lbs Rebar Spacing = 8.00 ...resultant ecc. = 10.99 in Rebar Placed at = Center Design Data - Soil Pressure @ Toe = 1,777 psf OK fb/FB+fa/Fa = 0.844 Soil Pressure @ Heel = 78 psf OK Total Force @ Section lbs= 2,116.6 Allowable = 1,995 psf Soil Pressure Less Than Allowable Moment....Actual ft#= 6,094.0 ACI Factored @ Toe = 2,133 psf Moment Allowable = 7,221.8 ACI Factored @ Heel = 93 psf Shear Actual psi= 37.8 Footing Shear @ Toe = 0.0 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 49.5 psi OK Wall Weight = 100.0 Allowable = 75.0 psi Rebar Depth 'd' in= 4.00 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 19.75 LAP SPLICE IF BELOW in= Lateral Sliding Force = 1,716.3 lbs HOOK EMBED INTO FTG in= 6.84 less 100%Passive Force= - 0.0 lbs Lap splice above base reduced by stress ratio less 100%Friction Force = - 1,947.8 lbs Hook embedment reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data ....for 1.5: 1 Stability = 626.6 lbs NG I'm psi= Fs psi= Solid Grouting = Use Half Stresses = Modular Ratio'n' = Load Factors Building Code IBC 2009,ACI Short Term Factor Dead Load 1.200 Equiv.Solid Thick. = Live Load 1.600 Masonry Block Type = Medium Weight Earth,H 1.600 Masonry Design Method = ASD Wind,W 1.600 fConcrete Data Seismic,E 1.000 Fy psi= 2,500.0 Fy psi= 60,000.0 Footing Dimensions& Strengths-1 Footing Design Results Toe Width = 0.50 ft Toe Heel Heel Width = 5.50 Factored Pressure = 2,133 93 psf Total Footing Width = 6.00 Mu':Upward = 259 0 ft-# Footing Thickness = 12.00 in Mu':Downward = 23 748 ft-# Mu: Design = 237 748 ft-# Key Width = 0.00 in Actual 1-Way Shear = 0.00 49.52 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #4 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #4 @ 18.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd,Mu<S'Fr Heel:Not req'd,Mu<S*Fr Key: No key defined Use menu item Settings>Printing&Title Block Title : 7'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 7'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Summary of Overturning & Resisting Forces & MomentsI OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft4 lbs ft ft-# Heel Active Pressure = 1,120.0 2.67 2,986.7 Soil Over Heel = 3,721.7 3.58 13,336.0 Surcharge over Heel = 101.8 4.00 407.3 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 193.3 3.58 692.8 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= 'Axial Live Load on Stem = Seismic Earth Load = 280.1 4.80 1,344.7 Soil Over Toe = 3,721.7 Seismic Stem Self Wt = 300.0 4.75 1,425.0 Surcharge Over Toe = Total 1,716.3 O.T.M. 5,756.5 Stem Weight(s) = 750.0 0.83 625.0 Earth @ Stem Transitions= _ = Footing Weight = 900.0 3.00 2,700.0 Resisting/Overturning Ratio = 3.01 Key Weight = Vertical Loads used for Soil Pressure= 5,565.0 lbs Vert.Component = Total= 5,565.0 lbs R.M.= 17,353.8 If seismic included the min.OTM and sliding *Axial live load NOT included in total displayed,or used for overturning ratios may be 1.1 per IBC'09, 1807.2.3. resistance,but is included for soil pressure calculation. DESIGNER NOTES: Use menu item Settings>Printing&Title Block Title : 8'-0"Wall Page: to set these five lines of information Job# Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 8'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING [Criteria 1 Soil Data u, Retained Height = 8.00 ft Allow Soil Bearing = 1,500.0 psf ?'; ,., .y„_ , �-y?,z, ',`.� _' Equivalent Fluid Pressure Method +' Wall height above soil = 0.50 ft = !-.-.: ."-7,,,t.: Equivalent Heel Active Pressure 35.0 psf/ft •_ ,', Slope Behind Wall = 0.00. 1 = {;t ;' ^:. .+ r:. ,,4`, Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft .1s:;{„lixs: ' Water height over heel = 0.0 ft Soil Density,Heel = 110.00 pcf 7.' < ;It n< .r;: +Y E ,,"- fTiV Soil Density,Toe = 110.00 pcf } f e,i , . t *:' FootingllSoil Friction = 0.350 n' $I {a: V-'''' +"', `{ t, .' lri , , Soil height to ignore "e` " -ss- , _ , for passive pressure = 12.00 in x '� ,: s , .S,; *,`-a (5s :;fts.-'.r-..moth'e'. :1n.n.RJe.'.tai».':.:41;i::=41'.:i.Yk4 Surcharge Loads 0 Lateral Load Applied to Stem ` Adjacent Footing Load 1 Surcharge Over Heel = 40.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft has been increased 1.00 Footin T e Axial Load Applied to Stem g by a factor of gType Base Above/Below Soil 0.0 ft Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Design Summary ! Stem Construction 1 Top Stem Stem OK Wall Stability Ratios Design Height Above Ftc ft= 0.00 Overturning = 5.11 OK Wall Material Above"Ht" = Concrete Sliding = 1.55 OK Thickness = 8.00 Rebar Size = # 5 Total Bearing Load = 6,769 lbs Rebar Spacing = 10.00 ...resultant ecc. = 5.74 in Rebar Placed at = Edge Soil Pressure @ Toe = 1,430 psf OK Design Data Soil Pressure @ Heel = 576 psf OK fb/FB+fa/Fa = 0.564 1500 Total Force @ Section lbs= 1,954.9 , Allowable = psf Moment....Actual ft-#= 5,430.3 Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,715 psf Moment Allowable = 9,623.1 ACI Factored @ Heel = 691 psf Shear Actual psi= 26.3 Footing Shear @ Toe = 0.6 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 60.8 psi OK Wall Weight = 100.0 Allowable = 75.0 psi Rebar Depth 'd' in= 6.19 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 13.20 LAP SPLICE IF BELOW in= Lateral Sliding Force = 1,532.0 lbs HOOK EMBED INTO FTG in= 6.00 less 100%Passive Force= - 0.0 lbs less 100%Friction Force = - 2,369.2 lbs Lap splice above base reduced by stress ratio Hook embedment reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data ....for 1.5: 1 Stability = 0.0 lbs OK fm psi= Fs psi= Solid Grouting = Use Half Stresses = Modular Ratio'n' = Load Factors Building Code IBC 2009,ACI Short Term Factor = Dead Load 1.200 Equiv.Solid Thick. = Masonry Block Type = Medium Weight Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data -- - Wind,W 1.600 fc psi= 2,500.0 Seismic,E 1.000 Fy psi= 60,000.0 Use menu item Settings>Printing&Title Block Title : 8'-0"Wall Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 8'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING [Footing Dimensions & Strengths I Footing Design Results j Toe Width = 0.75 ft Toe Heel Heel Width = 6.00 Factored Pressure = 1,715 691 psf Total Footing Width = 6.75 Mu':Upward = 472 0 ft-# Footing Thickness = 12.00 in Mu':Downward = 51 910 ft-# Mu: Design = 421 910 ft-# Key Width = 0.00 in Actual 1-Way Shear = 0.63 60.82 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #5 @ 18.00 in f = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #5 @ 10.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd,Mu<S*Fr Heel:Not req'd,Mu<S*Fr Key: No key defined Summary of Overturning & Resisting Forces& Moments OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 1,417.5 3.00 4,252.5 Soil Over Heel = 4,693.3 4.08 19,164.4 Surcharge over Heel = 114.5 4.50 515.5 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 213.3 4.08 871.1 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= *Axial Live Load on Stem = = Soil Over Toe = 4,693.3 Surcharge Over Toe = Total 1,532.0 O.T.M. 4,768.0 Stem Weight(s) = 850.0 1.08 920.8 Earth @ Stem Transitions= = = Footing Weight = 1,012.5 3.38 3,417.2 Resisting/Overturning Ratio = 5.11 Key Weight = Vertical Loads used for Soil Pressure= 6,769.2 lbs Vert.Component = Total= 6,769.2 lbs R.M.= 24,373.6 *Axial live load NOT included in total displayed,or used for overturning resistance,but is included for soil pressure calculation. DESIGNER NOTES: Use menu item Settings>Printing&Title Block Title : 8'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 8'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING LCriteria 1 LSoil Data Retained Height = 8.00 ft Allow Soil Bearing = 1,995.0 psf " Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method ; Heel Active Pressure = 35.0 psf/ft • . '}: -7'.:, - ,;, : Slope Behind Wall = 0.00: 1 _ r > ' =:: -"' "`' Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft • .':;�z .i.547,--,-:-.1••„,..'F; --• ; Water height over heel = 0.0 Soil Density,Heel = r `y'` ft 110.00 pcf }� r"��.x j'j.;:..e,;,,�",' ari};_,. Soil Density,Toe = 110.00 pcf i �"1� 4 " .,,=4^i;• FootingliSoil Friction = ., .,�„ .•• ,;e ' .ar�=•'.`, 0.350 r�f_s,_.�c;�, r t.. '� „�t:".;••n+�F= Soil height to ignore -V;N rKt -a;*Ly.fi§ � t.: Y n for passive pressure = 12.00 in 41,4t,ti$ ! ,.kjf 5 Surcharge Loads r Lateral Load Applied to Stem ` Adjacent Footing Load Surcharge Over Heel = 40.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft has been increased 1.00 Axial Load Applied to Stem Footing Type by a factor of Base Above/Below Soil Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall = 0.0 ft Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Earth Pressure Seismic Load j Kae for seismic earth pressure = 0.389 Added seismic base force 354.6 lbs Design Kh = 0.166 g Ka for static earth pressure = 0.277 Difference: Kae-Ka = 0.112 Using Mononobe-Okabe/Seed-Whitman procedure Stem Weight Seismic Load 1 Fp/Wp Weight Multiplier = 0.400 g Added seismic base force 242.9 lbs Use menu item Settings>Printing&Title Block Title : 8'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 8'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING [-Design Summary 1 _Stem Construction �1 Top Stem Stem OK Wall Stability Ratios Design Height Above Ftc ft= 0.00 Overturning = 3.06 OK Wall Material Above"Ht" = Concrete Sliding = 1.11 Ratio< 1.5! Thickness = 8.00 Rebar Size = # 5 Total Bearing Load = 6,769 lbs Rebar Spacing = 10.00 ...resultant ecc. = 11.40 in Rebar Placed at = Edge Soil Pressure @ Toe = 1,850 psf OK Design Data - Soil Pressure @ Heel = 156 psf OK /FB+fa/Fa = 0.911 Allowable = 1,995 Total Force @ Section lbs= 2,689.5 psf Moment....Actual ft-#= 8,769.3 Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,219 psf Moment Allowable = 9,623.1 ACI Factored @ Heel = 187 psf Shear Actual psi= 30.9 Footing Shear @ Toe = 0.8 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 60.8 psi OK Wall Weight = 100.0 Allowable = 75.0 psi Rebar Depth 'd' in= 6.19 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 21.32 Lateral Sliding Force = 2,129.5 lbs LAP SPLICE IF BELOW in= less 100%Passive Force= - 0.0 lbs HOOK EMBED INTO FTG in= 7.84 less 100%Friction Force = - 2,369.2 lbs Lap splice above base reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data Hook embedment reduced by stress ratio ....for 1.5: 1 Stability = 825.0 lbs NG fm psi= Fs • psi= Solid Grouting = Use Half Stresses = Modular Ratio'n' = Load Factors Building Code IBC 2009,ACI Short Term Factor = Dead Load 1.200 Equiv.Solid Thick. = Live Load 1.600 Masonry Block Type = Medium Weight Earth,H 1.600 Masonry Design Method = ASD Wind,W 1.600 Concrete Data fc psi= 2,500.0 Seismic,E 1.000 Fy psi= 60,000.0 Footing Dimensions & Strengths 1I Footing Design Results Toe Width = 0.75 ft Toe Heel Heel Width = 6.00 Factored Pressure = 2,219 187 psf Total Footing Width = 6.75 Mu':Upward = 603 0 ft-# Footing Thickness = 12.00 in Mu':Downward = 51 910 ft-# Mu: Design = 552 910 ft-# Key Width = 0.00 in Actual 1-Way Shear = 0.83 60.82 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #5 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #5 @ 10.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd,Mu<S'Fr Heel: Not req'd,Mu<S*Fr Key: No key defined Use menu item Settings> Printing&Title Block Title : 8'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 8'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Summary of Overturning & Resisting Forces & Moments OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 1,417.5 3.00 4,252.5 Soil Over Heel = 4,693.3 4.08 19,164.4 Surcharge over Heel = 114.5 4.50 515.5 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 213.3 4.08 871.1 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= 'Axial Live Load on Stem = Seismic Earth Load = 354.6 5.40 1,914.6 Soil Over Toe = 4,693.3 Seismic Stem Self Wt = 340.0 5.25 1,785.0 Surcharge Over Toe = Total 2,129.5 O.T.M. 7,957.6 Stem Weight(s) = 850.0 1.08 920.8 Earth @ Stem Transitions= Footing Weight = 1,012.5 3.38 3,417.2 Resisting/Overturning Ratio = 3.06 Key Weight = Vertical Loads used for Soil Pressure= 6,769.2 lbs Vert.Component = Total= 6,769.2 lbs R.M.= 24,373.6 If seismic included the min.OTM and sliding 'Axial live load NOT included in total displayed,or used for overturning ratios may be 1.1 per IBC'09, 1807.2.3. resistance,but is included for soil pressure calculation. DESIGNER NOTES: Use menu item Settings>Printing&Title Block Title i 9'-0"Wall Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 9'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Criteria 1 [Soil Data -I ( , Allow Soil Bearingx Retained Height = 9.00 ft = 1,500.0 psf t>'� C , Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method Kzi``�,, -ti Heel Active Pressure = 35.0 psf/fl Slope Behind Wall = 0.00: 1 = Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft Water height over heel = 0.0 ft Soil Density, Heel = 110.00 pcf z `•I,1y'.,_',7, ,, Soil Density,Toe = 110.00 pcf i • s ti f ,' FootingilSoil Friction = 0.350 ` , z a. Soil height to ignore `t. ` i l c_46: ,4 P- i ', 4 ,tn- - 'tro for passive pressure = 12.00 in s .7 Surcharge Loads 1 Lateral Load Applied to Stem ` Adjacent Footing Load Surcharge Over Heel = 40.0 psf = FootingLoad = 0.0 lbs g Lateral Load 0.0#/ft Adjacent Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft has been increased 1.00 Axial Load Applied to Stem Footing Type by a factor of Base Above/Below Soil Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall = 0.0 ft Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Design Summary ! Stem Construction ` Top Stem �1 Stem OK Wall Stability Ratios Design Height Above Ftc ft= 0.00 Overturning = 5.80 OK Wall Material Above"Ht" = Concrete Sliding = 1.58 OK Thickness = 10.00 Rebar Size = # 5 Total Bearing Load = 8,482 lbs Rebar Spacing = 10.00 ...resultant ecc. = 4.09 in Rebar Placed at = Edge Design Data Soil Pressure @ Toe = 1,331 psf OK fb/FB+fa/Fa = 0.588 Soil Pressure @ Heel = 789 psf OK Allowable = 1,500 Total Force @ Section lbs= 2,451.3 psf Moment....Actual ft-#= 7,628.7 Soil Pressure Less Than Allowable ACI Factored©Toe = 1,598 psf Moment Allowable = 12,971.1 ACI Factored @ Heel = 947 psf Shear Actual psi= 24.9 Footing Shear @ Toe = 7.4 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 74.3 psi OK Wall Weight = 125.0 Allowable = 75.0 psi Rebar Depth 'd' in= 8.19 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 13.76 Lateral Sliding Force = 1,877.3 lbs LAP SPLICE IF BELOW in= less 100%Passive Force= - 0.0 lbs HOOK EMBED INTO FTG in= 6.03 less 100%Friction Force = - 2,968.6 lbs Lap splice above base reduced by stress ratio Hook embedment reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data ....for 1.5: 1 Stability = 0.0 lbs OK fm psi= Fs psi= Solid Grouting = Use Half Stresses = Modular Ration' = Load Factors - - Short Term Factor = Building Code IBC 2009,ACI Equiv.Solid Thick. Dead Load 1.200 Masonry Block Type = Medium Weight Live Load 1.600 Masonry Design Method = ASD Earth,H 1.600 Concrete Data Wind,W 1.600 fc psi= 2,500.0 Seismic,E 1.000 Fy psi= 60,000.0 Use menu item Settings>Printing&Title Block Title : 9'-0"Wall Page: to set these five lines of information Job# • Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 9'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING _Footing Dimensions & Strengths ! Footing Design Results Toe Width = 1.25 ft Toe Heel Heel Width = 6.75 Factored Pressure = 1,598 947 psf Total Footing Width = 8.00 Mu':Upward = 1,222 0 ft-# Footing Thickness = 12.00 in Mu':Downward = 141 1,120 ft-# Mu: Design = 1,081 1,120 ft-# Key Width = 0.00 in Actual 1-Way Shear = 7.41 74.32 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #5 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #5 @ 10.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd,Mu<S*Fr Heel:Not req'd,Mu<S*Fr Key: No key defined _Summary of Overturning & Resisting Forces& Moments OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 1,750.0 3.33 5,833.3 Soil Over Heel = 5,857.5 5.04 29,531.6 Surcharge over Heel = 127.3 5.00 636.4 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 236.7 5.04 1,193.2 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= *Axial Live Load on Stem = = Soil Over Toe = 5,857.5 Surcharge Over Toe = Total 1,877.3 O.T.M. 6,469.7 Stem Weight(s) = 1,187.5 1.67 1,979.2 Earth @ Stem Transitions= = = Footing Weight = 1,200.0 4.00 4,800.0 Resisting/Overturning Ratio = 5.80 Key Weight = Vertical Loads used for Soil Pressure= 8,481.7 lbs Vert.Component = Total= 8,481.7 lbs R.M.= 37,503.9 *Axial live load NOT included in total displayed,or used for overturning resistance,but is included for soil pressure calculation. DESIGNER NOTES: • Use menu item Settings>Printing&Title Block Title : 9'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 9'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Criteria LSoil Data q t :,.. Retained Height = 9.00 ft Allow Soil Bearing = 1,995.0 psf Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method _.-'`` Heel Active Pressure = 35.0 psf/ft ',- ;'. ,'-, .•I Wall Slope Behind Wall = 0.00: 1 fT r Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft Water height over heel = 0.0 ft Soil Density, Heel = 110.00 pcf ;..} :? 4 ,.,k°;s=ix<• Soil Density,Toe = 110.00 pcf s t') ` ,1,} zr,"'"•`"«'?,,>� Footin Soil Friction = 0.350 r:,;1.,";.,-,:-.':?',x -' ---;,;•;.'1,74-4-,4',2,_1,,,..L', 911 r� ,•:-, 1 r iris-v-� Soil height to ignore p ;,. , w� n. ' �_-1' for passive pressure = 12.00 in %`'-":'h�,„.a`w , ,yi i Surcharge Loads Lateral Load Applied to Stem ' Adjacent Footing Load Surcharge Over Heel = 40.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft Axial Load Applied to Stem i has been increased 1.00 Footing Type Line Load by a factor of Base Above/Below Soil Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall = 0.0 ft Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Earth Pressure Seismic Load a Kae for seismic earth pressure = 0.389 Added seismic base force 437.7 lbs Design Kh = 0.166 g Ka for static earth pressure = 0.277 Difference: Kae-Ka = 0.112 Using Mononobe-Okabe/Seed-Whitman procedure Stem Weight Seismic Load 1 Fp/Wp Weight Multiplier = 0.400 g Added seismic base force 339.3 lbs Use menu item Settings>Printing&Title Block Title : 9'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 9'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING II Design Summary ! LStem Construction 4 Top Stern Stem OK Wall Stability Ratios Design Height Above Ftc ft= 0.00 Overturning = 3.39 OK Wall Material Above"Ht" = Concrete Sliding = 1.12 Ratio<1.5! Thickness = 10.00 Rebar Size = # 5 Total Bearing Load = 8,482 lbs Rebar Spacing = 10.00 ...resultant ecc. = 10.57 in Rebar Placed at = Edge Design Data Soil Pressure @ Toe = 1,760 psf OK fb/FB+fa/Fa = 0.970 Soil Pressure @ Heel = 360 psf OK Allowable = 1 995 Total Force @ Section lbs= 3,425.7 psf Moment....Actual ft-#= 12,581.6 Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,113 psf Moment Allowable = 12,971.1 ACI Factored @ Heel = 432 psf Shear Actual psi= 29.8 Footing Shear @ Toe = 10.0 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 74.3 psi OK Wall Weight = 125.0 Allowable = 75.0 psi Rebar Depth 'd' in= 8.19 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 22.70 Lateral Sliding Force = 2,654.3 lbs LAP SPLICE IF BELOW in= less 100%Passive Force = - 0.0 lbs HOOK EMBED INTO FTG in= 8.26 less 100%Friction Force = - 2,968.6 lbs Lap splice above base reduced by stress ratio Hook embedment reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data ....for 1.5: 1 Stability = 1,012.8 lbs NG fm psi= Fs psi= Solid Grouting = Use Half Stresses = Load Factors Modular Ration' _ Building Code IBC 2009,ACI Short Term Factor = Dead Load 1.200 Equiv.Solid Thick. = Live Load 1.600 Masonry Block Type = Medium Weight Earth,H 1.600 Masonry Design Method = ASD Wind,W 1.600 Concrete Data fc psi= 2,500.0 Seismic, E 1.000 Fy psi= 60,000.0 Footing Dimensions & Strengths 1 Footing Design Results i Toe Width = 1.25 ft Toe Heel Heel Width = 6.75 Factored Pressure = 2,113 432 psf Total Footing Width = 8.00 Mu':Upward = 1,582 0 ft-# Footing Thickness = 12.00 in Mu':Downward = 141 1,120 ft-# Mu: Design = 1,441 1,120 ft-# Key Width = 0.00 in Actual 1-Way Shear = 9.96 74.32 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #5 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #5 @ 10.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd,Mu<S*Fr Heel:Not req'd,Mu<S*Fr Key: No key defined • Use menu item Settings>Printing&Title Block Title : 9'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 9'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING L Summary of Overturning & Resisting Forces& Moments OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-it . Heel Active Pressure = 1,750.0 3.33 5,833.3 Soil Over Heel = 5,857.5 5.04 29,531.6 Surcharge over Heel = 127.3 5.00 636.4 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 236.7 5.04 1,193.2 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= 'Axial Live Load on Stem = Seismic Earth Load = 437.7 6.00 2,626.4 Soil Over Toe = 5,857.5 Seismic Stem Self Wt = 475.0 5.75 2,731.3 Surcharge Over Toe = Total 2,654.3 O.T.M. 11,047.0 Stem Weight(s) = 1,187.5 1.67 1,979.2 Earth @ Stem Transitions= Footing Weight = 1,200.0 4.00 4,800.0 Resisting/Overturning Ratio = 3.39 Key Weight = Vertical Loads used for Soil Pressure= 8,481.7 lbs Vert.Component = Total= 8,481.7 lbs R.M.= 37,503.9 If seismic included the min.OTM and sliding 'Axial live load NOT included in total displayed,or used for overturning ratios may be 1.1 per IBC'09, 1807.2.3. resistance,but is included for soil pressure calculation. DESIGNER NOTES: Use menu item Settings> Printing&Title Block Title : 10'-0"Wall Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 10'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Criteria I Soil Data f Retained Height = 10.00 ft Allow Soil Bearing = 1,500.0 psf r ' ' k Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method -li} Heel Active Pressure = 35.0 psf/ft Slope Behind Wall = 0.00: 1 = P -, Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft . Water height over heel = 0.0 ft Soil Density,Heel = 110.00 pcf 43 110.00 1,.., g, Soil Density,Toe = pcf .'; r;::! ., FootingllSoil Friction = 0.350 . ' . i-:' -.;':'-'-'..-A4'.,''-1':.,..i:i. Soil height to ignore1. v ,v s. -T;, ;` 15' for passive pressure = 12.00 in _ • s V .a.26a 11}''r:='3c ;I. Surcharge Loads ` Lateral Load Applied to Stem IIAdjacentFooting Load Surcharge Over Heel = 40.0 psf ® Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft has been increased 1.00 Axial Load Applied to Stem Footing Type Line Load by a factor of Base Above/Below Soil Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall = 0.0 ft Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in jDesign Summary 8 LStem Construction 1 Top Stem Stem OK Wall Stability Ratios Design Height Above Ftc ft= 0.00 Overturning = 5.58 OK Wall Material Above"Ht" = Concrete Sliding = 1.55 OK Thickness = 10.00 Rebar Size = # 5 Total Bearing Load = 10,159 lbs Rebar Spacing = 7.50 ...resultant ecc. = 4.26 in Rebar Placed at = Edge Design Data Soil Pressure @ Toe = 1,444 psf OK fb/FB+fa/Fa = 0.610 Soil Pressure @ Heel = 878 psf OK Total Force @ Section lbs= 3,003.6 Allowable = 1,500 psf Moment....Actual ft-#= 10,351.5 Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,733 psf Moment Allowable = 16,968.2 ACI Factored @ Heel = 1,054 psf Shear Actual psi= 30.6 Footing Shear @ Toe = 7.4 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 74.1 psi OK Wall Weight = 125.0 Allowable = 75.0 psi Rebar Depth 'd' in= 8.19 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 14.28 Lateral Sliding Force = 2,324.3 lbs LAP SPLICE IF BELOW in= less 100%Passive Force= - 45.1 lbs HOOK EMBED INTO FTG in= 6.21 less 100%Friction Force = - 3,555.6 lbs Lap splice above base reduced by stress ratio Hook embedment reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data - ....for 1.5: 1 Stability = 0.0 lbs OK fm psi= Fs psi= Solid Grouting = Use Half Stresses = Load Factors -- _ Modular Ratio'n' _ Building Code IBC 2009,ACI Short Term Factor Dead Load 1.200 Equiv.Solid Thick. = Live Load 1.600 Masonry Block Type = Medium Weight Earth, H 1.600 Masonry Design Method = ASD Concrete Data Wind,W 1.600 fc psi= 2,500.0 Seismic, E 1.000 Fy psi= 60,000.0 Use menu item Settings> Printing&Title Block Title : 10'-0"Wall Page: to set these five lines of information • Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 10'-0"retained This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING [Footing Dimensions & Strengths I Footing Design Results Toe Width = 1.50 ft Toe Heel Heel Width = 7.25 Factored Pressure = 1,733 1,054 psf Total Footing Width = 8.75 Mu':Upward = 1,905 0 ft-# Footing Thickness = 14.00 in Mu':Downward = 236 1,318 ft-# Mu: Design = 1,669 1,318 ft-# Key Width = 0.00 in Actual 1-Way Shear = 7.43 74.12 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #5 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #5 @ 10.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm= 3.00 in Toe: Not req'd,Mu<S*Fr Heel:Not req'd,Mu<S*Fr Key: No key defined _Summary of Overturning & Resisting Forces& Moments OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 2,182.2 3.72 8,122.5 Soil Over Heel = 7,058.3 5.54 39,114.9 Surcharge over Heel = 142.1 5.58 793.5 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 256.7 5.54 1,422.4 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= *Axial Live Load on Stem = = Soil Over Toe = 7,058.3 Surcharge Over Toe = Total 2,324.3 O.T.M. 8,916.0 Stem Weight(s) = 1,312.5 1.92 2,515.6 Earth @ Stem Transitions= = = Footing Weight = 1,531.3 4.38 6,699.2 Resisting/Overturning Ratio = 5.58 Key Weight = Vertical Loads used for Soil Pressure= 10,158.8 lbs Vert.Component = Total= 10,158.8 lbs R.M.= 49,752.1 *Axial live load NOT included in total displayed,or used for overturning resistance,but is included for soil pressure calculation. DESIGNER NOTES: Use menu item Settings> Printing&Title Block Title : 10'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 10'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To:CORE ENGINEERING Criteria Soil Data ` ..`. tl a -,. Retained Height = 10.00 ft Allow Soil Bearing = 1,995.0 psf -_ Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method Heel Active Pressure = 35.0 psf/ft - !iY', Slope Behind Wall = 0.00: 1 _ 4 Height of Soil over Toe = 0.00 in Passive Pressure = 250.0 psf/ft ;tj Water height over heel = 0.0 ft Soil Density, Heel = 110.00 pcf Soil Density,Toe = 110.00 pcf • _ FootingllSoil Friction = 0.350 p0- ` Soil height to ignore r uti tF *sx for passive pressure = 12.00 in I '_, ' , ,, Surcharge Loads 9 Lateral Load Applied to Stem 9 Adjacent Footing Load 9 Surcharge Over Heel = 40.0 psf Lateral Load = 0.0#/ft Adjacent Footing Load = 0.0 lbs Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in Used for Sliding&Overturning The above lateral load Wall to Ftg CL Dist = 0.00 ft has been increased 1.00 Axial Load Applied to Stem Footing Type Line Load by a factor of Base Above/Below Soil Axial Dead Load = 0.0 lbs Wind on Exposed Stem = 0.0 psf at Back of Wall = 0.0 ft Axial Live Load = 0.0 lbs Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in I Earth Pressure Seismic Load ii Kae for seismic earth pressure = 0.389 Added seismic base force 545.8 lbs Design Kh = 0.166 g +t Ka for static earth pressure = 0.277 Difference: Kae-Ka = 0.112 Using Mononobe-Okabe/Seed-Whitman procedure Stem Weight Seismic Load 9 Fp/Wp Weight Multiplier = 0.400 g Added seismic base force 375.0 lbs Use menu item Settings>Printing&Title Block Title 10'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 10'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING Design Summary ' Stem Construction I Top Stem Stem OK Wall Stability Ratios Design Height Above Ftc ft= 0.00 Overturning = 3.32 OK Wall Material Above"Ht" = Concrete Sliding = 1.11 Ratio<1.5! Thickness = 10.00 Rebar Size = # 5 Total Bearing Load = 10,159 lbs Rebar Spacing = 7.50 ...resultant ecc. = 11.42 in Rebar Placed at = Edge Design Data Soil Pressure @ Toe = 1,919 psf OK fb/FB+fa/Fa = 0.990 Soil Pressure @ Heel = 403 psf OK Total Force @ Section lbs= 4,145.2 Allowable = 1,995 psf Moment....Actual ft-#= 16,806.9 Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,303 psf Moment Allowable = 16,968.2 ACI Factored @ Heel = 484 psf Shear Actual psi= 35.9 Footing Shear©Toe = 10.1 psi OK Shear Allowable psi= 75.0 Footing Shear @ Heel = 74.1 psi OK Wall Weight = 125.0 Allowable = 75.0 psi Rebar Depth 'd' in= 8.19 Sliding Calcs (Vertical Component Used) LAP SPLICE IF ABOVE in= 23.18 Lateral Sliding Force = 3,245.1 lbs LAP SPLICE IF BELOW in= less 100%Passive Force= - 45.1 lbs HOOK EMBED INTO FTG in= 8.57 less 100%Friction Force = - 3,555.6 lbs Lap splice above base reduced by stress ratio Hook embedment reduced by stress ratio Added Force Req'd = 0.0 lbs OK Masonry Data ....for 1.5: 1 Stability = 1,266.9 lbs NG fm psi= Fs psi= Solid Grouting = Use Half Stresses = Load Factors Modular Ratio'n' = Building Code IBC 2009,ACI Short Term Factor = Dead Load 1.200 Equiv.Solid Thick. = Live Load 1.600 Masonry Block Type = Medium Weight Earth,H 1.600 Masonry Design Method = ASD Wind,W 1.600 Concrete Data fc psi= 2,500.0 Seismic, E 1.000 Fy psi= 60,000.0 Footing Dimensions & Strengths I Footing Design Results Toe Width = 1.50 ft Toe Heel Heel Width = 7.25 Factored Pressure = 2,303 484 psf Total Footing Width = 8.75 Mu':Upward = 2,474 0 ft-# Footing Thickness = 14.00 in Mu':Downward = 236 1,318 ft-# Mu: Design = 2,237 1,318 ft-# Key Width = 0.00 in Actual 1-Way Shear = 10.06 74.12 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = #5 @ 18.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = #5 @ 10.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min.As% = 0.0018 Other Acceptable Sizes&Spacings Cover @ Top 2.00 @ Btm.= 3.00 in Toe: Not req'd,Mu<S*Fr Heel:Not req'd,Mu<S'Fr Key: No key defined Use menu item Settings>Printing&Title Block Title : 10'-0"Wall with seismic Page: to set these five lines of information Job# : Dsgnr: DNS Date: 20 JUN 2012 for your program. Description.... 10'-0"retained with seismic This Wall in File:g:\structural projects\projects\2012 projects\b1 RetainPro 10 (c)1987-2011, Build 10.12.1.13 License:KW-06059393 Cantilevered Retaining Wall Design Code: IBC 2009,ACI 318-08,ACI 530-08 License To: CORE ENGINEERING Summary of Overturning & Resisting Forces & Moments OVERTURNING RESISTING Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 2,182.2 3.72 8,122.5 Soil Over Heel = 7,058.3 5.54 39,114.9 Surcharge over Heel = 142.1 5.58 793.5 Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = 256.7 5.54 1,422.4 Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem= Load @ Stem Above Soil= *Axial Live Load on Stem = Seismic Earth Load = 545.8 6.70 3,657.0 Soil Over Toe = 7,058.3 Seismic Stem Self Wt = 525.0 6.42 3,368.8 Surcharge Over Toe = Total 3,245.1 O.T.M. 14,979.2 Stem Weight(s) = 1,312.5 1.92 2,515.6 Earth @ Stem Transitions= Footing Weight = 1,531.3 4.38 6,699.2 Resisting/Overturning Ratio = 3.32 Key Weight = Vertical Loads used for Soil Pressure= 10,158.8 lbs Vert.Component = Total= 10,158.8 lbs R.M.= 49,752.1 If seismic included the min.OTM and sliding *Axial live load NOT included in total displayed,or used for overturning ratios may be 1.1 per IBC'09, 1807.2.3. resistance,but is included for soil pressure calculation. DESIGNER NOTES: