Loading...
Report Fuis .- (JCIe SYSTEM RECORD OF COMPLETION � fo,zY This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modem this form as needed to provide a more complete and/or clear record Insert N/A in all unused lines. Attach additional sheets,data, or calculations as necessary to provide a complete record. Form Completion Date: 11-05-15 Supplemental Pages Attached: 1. PROPERTY INFORMATION Name of property: IFly Indoor Skydiving Address: 10655 SW Greenburg Rd.Tigard,OR.97233 Description of property: B-Business Group Name of property representative: IFly Indoor Skydiving Address: 10655 SW Greenburg Rd.Tigard,OR.97233 Phone: Fax: E-mail: 2. INSTALLATION, SERVICE,TESTING, AND MONITORING INFORMATION Installation contractor: Ertel!Electric Address: 5293 NE Elam Young Parkway Hillsboro,OR.97124 Phone: Fax: E-mail: Service organization: SimplexGrinnell Address: 6305 SW Rosewood St Lae Oswego OR.97035 Phone: Fax: E-mail: Testing organization: Address: Phone: Fax: E-mail: Effective date for test and inspection contract: Monitoring organization: SimplexGrinnell Address: Phone: Fax: E-mail: Account number: 302-1198 Phone line 1: Phone line 2: Means of transmission: SDACT/Cell Entity to which alarms are retransmitted: Phone: 3. DOCUMENTATION On-site location of the required record documents and site-specific software: Site Office 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: ®New system ❑Modification to existing system Permit number: NFPA 72 edition: 2013 4.1 Control Unit Manufacturer: SimplexGrinnell Model number: 4010ES 4.2 Software and Firmware Firmware revision number: 3.02.09 4.3 Alarm Verification ®This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds Copyright 02012 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 AC Control panel amps: 8 Overcurrent protection: Type: Breaker Amps: 20 Branch circuit disconnecting means location: 1L1 Sect 2 Number. 71 5.1.2 Secondary Power Type of secondary power. Fire Alarm Panel Location,if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode(hours): 24 In alarm mode(minutes): 5 5.2 Control Unit ® This system does not have power extender panels ❑ Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line Device Power Initiating Device 1 B Notification Appliance 1 B Other(specify): 7. REMOTE ANNUNCIATORS Type Location SCU LED Main Lobby 8. INITIATING DEVICES Addressable or Type Quantity Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 1 Addressable Alarm Smoke Detectors 6 Addressable Alarm Duct Smoke Detectors 13 Addressable Supervisory Heat Detectors 3 Addressable Alarm Gas Detectors Watertlow Switches 5 conventional Alarm Tamper Switches 7 conventional Supervisory Copyright©2012 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible Visible 19 Combination Audible and Visible 11 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers 1 Door Unlocking Elevator Recall 3 Elevator Shunt Trip 1 11. INTERCONNECTED SYSTEMS ® This system does not have interconnected systems. ❑ Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as spe • •• h in has ••-n installed according to all NFPA standards cited herein. Signed: • Printed name: ---5oS‹,c\A. \t Date: 11/05/15 Organizatio • rtell Electric Title: Foreman \ Phone: 12.2 em Operational Test This system as sp• fies herein , ested aces • _ • all NFPA standards cited herein. Signed: /(A ` . Printed name: Ralph MacRoberts Date: 11/05/15 Organization: SimplexGrinn-/ Title: Tech Rep Phone: 12.3 Acceptance Test Date and time of acceptance test: C D�,t� 2' -� e^ Installing contractor representative:.c P Testing contractor representative: /A��I Property representative: AHJ representative: I ) .4 f Copyright O 2012 National Fire Protection Association.This form may be copied for individual use other than for resale.It may not be copied for commercial sale or distribution. (p. 3 of 3) LOCATION M & SETTING S TIC PRESSURE RES ID• = PRESSURE FLOW RATE PRESSURE " &FLOOR MOD I G) REDUCING LET(PSI) UTLET(PSI) INLET(PSI) 0.4, ET(PSI) FLOW(GPM) VALVE TEST HYDROSTATIC:Hydrostatic tests shall be made at not less than 200 PSI(13.6 bars)for 2 hours or 50 PSI(3.4 bars) TEST above static pressure in excess of 150 PSI(10.2 bars)for 2 hours. Differential dry-pipe valve clappers shall be left DESCRIPTION open during the test to prevent damage. All aboveground leakage shall be stopped. PNEUMATIC:Establish 40 PSI(2.7 bars)air pressure and measure drop,which shall not exceed 1'/a PSI(0.1 bars) In 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop,which shall not exceed 1'/:PSI(0.1 bars)in 24 hours. ALL PIPING HYDROSTATICALLY TESTED ATatoo PSI BARS FOR 2 FIRS IF NO,STATE REASON DRY PIPING PNEUMATICALLY TESTED ❑ YES ❑ NO EQUIPMENT OPERATES PROPERLY i YES ❑ NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVITIVES OF SODIUM SILICATE,BRINE,OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? YES ❑ NO TESTS DRAIN READING OF GUAGE LOCATED NEAR WATER RESIDUAL PRESSURE WITH VALVE TEST IN TEST SUPPLY TEST CONNECTION: VA PSI ( BARS) CONNECTION OPEN WIDE: 1i PSI( BARS) UNDERGROUND MAINS AND LEAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING VERIFIED BY COPY OF THE U FORM NO.85B ❑ YES ❑ NO OTHER EXPLAIN FLUSHED BY INSTALLER OF UNDER- GROUND SPRINKLER PIPING ❑ YES ❑ NO IF POWDER-DRIVEN FASTENERS ARE USED IN ❑ YES ❑ NO IF NO,EXPLAIN CONCRETE,HAS REPRESENTATIVE SAMPLE TESTING BEEN SATISFACTORILY COMPLETED? BLANK TESTING NUMBER USED l LOCATIONS NUMBER REMOVED GASKETS WELDED PIPING YES ❑ NO IF YES.... DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING YES ❑ NO PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.9,LEVEL AR-3? WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS Q YES ❑ NO QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS D10.9,LEVEL AR-3? DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALIT\ CONTROL PROCEDURE TO ENSURE THAT ALL DISCS ARE RETRIEVED,THAT OPENINGS IN PIPING ARE Ths YES ❑ NO SMOOTH,THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO YES ❑ NO (DISCS) ENSURE THAT ALL CUTOUTS(DISCS)ARE RETRIEVED? HYDRAULIC NAMEPLATE PROVIDED IF NO,EXPLAIN DATA ' ] YES ❑ NO NAMEPLATE DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN 1_CJ REMARKS NAME OF SPRINKLER CONTRACTOR -7C+ ��Y�- tOeGTIor% TEST WITNESSED FOR PROPERTY OWNER(SIGNED) TITLE DATE BY FOR SPRINKL C ACTO (,•' D) TITLE DATE �1-S-1S ADDITIONAL EXP ON I I TES Page 2 of 2 L Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work,inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving acuiorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship,or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME: Z ray PROPERTY ADDRESS: I0&SS SW Z-,reensbyrot 1Za, "Ts c‘. C)r DATE: 1%-S-1S ACCEPTED BY APPROVING AUTHORITIES(NAMES) \ PLANS +l1 0 1►c"° ADDRESS 1 INSTALLATION CONFORMS TO ACCEPTED PLANS YES ❑NO EQUIPMENT USED IS APPROVED ' YES ❑NO IF NO,EXPLAIN DEVIATIONS HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTR UCTED AS YES ❑NO TO LOCATION OF CONTROL VALVES AND CARE AND MAINTENANCE IF NO,EXPLAIN INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES? 1.SYSTEM COMPONENTS INSTRUCTIONS ']YES ❑NO 2.CARE AND MAINTENANCE INSTRUCTIONS YES ❑NO 3.NFPA 25 •]YES ❑NO LOCATION SUPPLIES BUILDINGS OF SYSTEM AI 1 YEAR OF ORIFICE TEMPERATURE M KE MODEL MANUFACTURE SIZE QUAANNTIIY� �RAQTING Vne..Ul,c, Yd-7o4 AotS Vir4-n.,`ic. V.2'10 44 ants '/ . \p 1"S S SPRINKLERS V`'' s•61`1a VeZ'1Co IN ..20 1S '(j Let 1 S PIPE AND TYPE OF PIPE (.Oak- =Yea r► , SAiw.-, FITTINGS TYPE OF FITTINGS Gn..s 4 T-4-0.— ALARM MAXIMUM TIME TO OPERATE ALARM DEVICE THROUGH TEST CONNECTION VALVE OR FLOW TYPF 1 MAKF MODFI. MIN SFC INDICATOR e/ Sylr•ern V 0.Y1L Ser.soi DRY VALVE Q.O.D. MAKE MODEL SERIAL NO. MA MODEL SERIAL NO. TIME TO TRIP TIME WATER ALARM THROUGH TEST WATE' AIR TRIP POINT REACHED OPERATED DRY PIPE CONECTION PRESSURE •• SSURE AIR PRESSURE TEST OUTLET PROPERLY OPERATING MIN SEC PSI ' I PSI MIN SEC YES NO TEST WITHOUT O.O.D. WITH 00D IF NO,EXPLAIN OPERATION ❑ PN MATIC El E CTRIC ❑ HYDR•LIC DELUGE A PREACTION PIPING SUPERVISED ■ YES ❑ NO 'ETECTING MEDIA SUPERVISE► ❑YES ❑NO VALVES 1•. VALVE OPERATE FROM THE a ANUAL TRIP,REMOTE,O' BOTH ❑ ❑ NO CO '.I L STATIONS IS THERE •■ ACCESSIBLE FACILITY IN CH CIRCUIT IF NO, ' .PLAIN FOR TESTING ❑ YES ❑ NO DOES EACH CIRCUIT OPER TE DOES EACH C I'CULT MAXIMUM P E TO MAKE MODEL 'ERVISION LOSS ALARM? OPERATE VALV' ' LEASE OPERATE RE .•SE S NO YES i NO MIN j SEC Page 1 of 2 Al armLog_2015_11_5.txt Service Port Page 1 Report 1 : Alarm Historical Log 11:58:12 am THU 05-NOV-15 ENTRY 1 9:20:21 am THU 05-NOV-15 LVL 1 SALES HALL 106 M1-7 PULL STATION FIRE ALARM ENTRY 2 9:24:12 am THU 05-NOV-15 FIRE ALARMS ACKNOWLEDGED AT MAIN PANEL ENTRY 3 9:24:13 am THU 05-NOV-15 ALARM SILENCE REQUESTED AT MAIN PANEL ENTRY 4 9:24:18 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 5 9:25:52 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 6 9:30:13 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 7 9:40:05 am THU 05-NOV-15 LVL 1 STAIR 3 105 WF/TAMPER M1-10 SPRINKLER MONITOR WATERFLOW ALARM ENTRY 8 9:40:07 am THU 05-NOV-15 FIRE ALARMS ACKNOWLEDGED AT MAIN PANEL ENTRY 9 9:40:26 am THU 05-NOV-15 ALARM SILENCE REQUESTED AT MAIN PANEL ENTRY 10 9:40:31 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 11 9:42:21 am THU 05-NOV-15 LVL 1 RISER RM 115 WF/TAMPER M1-11 SPRINKLER MONITOR WATERFLOW ALARM ENTRY 12 9:42:22 am THU 05-NOV-15 FIRE ALARMS ACKNOWLEDGED AT MAIN PANEL ENTRY 13 9:42:33 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 14 9:45:27 am THU 05-NOV-15 LVL 2 STAIR 206 WF/TAMPER M1-18 SPRINKLER MONITOR WATERFLOW ALARM Service Port Page 2 Report 1 : Alarm Historical Log 11: 58:13 am THU 05-NOV-15 ENTRY 15 9:45:29 am THU 05-NOV-15 FIRE ALARMS ACKNOWLEDGED AT MAIN PANEL ENTRY 16 9:45:33 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 17 9:49:03 am THU 05-NOV-15 LVL 3 STAIR 3 306 WF/TAMPER M1-26 SPRINKLER MONITOR WATERFLOW ALARM ENTRY 18 9:49:06 am THU 05-NOV-15 FIRE ALARMS ACKNOWLEDGED AT MAIN PANEL ENTRY 19 9:49:12 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 20 9:51:14 am THU 05-NOV-15 PENTHOUSE MECH ACCESS M1-33 SPRINKLER MONITOR WATERFLOW ALARM ENTRY 21 9:51:15 am THU 05-NOV-15 FIRE ALARMS ACKNOWLEDGED AT MAIN PANEL ENTRY 22 9:51:21 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 23 10:11:39 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 24 10:12:11 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 25 10:30:05 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 26 10:31:43 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 27 10:35:18 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 28 10:49:11 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 29 10:57:12 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 30 11:01:08 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL Service Port Page 3 Report 1 : Alarm Historical Log 11:58:14 am THU 05-NOV-15 ENTRY 31 11:11:35 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 32 11:11:44 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 33 11:12:08 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 34 11:23:37 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 35 11:30:53 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 36 11:31:13 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 37 11:31:20 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 38 11:35:35 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 39 11:41:45 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 40 11:45:26 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ENTRY 41 11:48:56 am THU 05-NOV-15 SYSTEM RESET REQUESTED AT MAIN PANEL ALARM HISTORICAL LOG REPORT COMPLETED Page 1 Al armLog_2015_1]L5.txt Page 2 TroubleLog_2015_11_5.txt Service Port Page 1 Report 2 : Trouble Historical Log 11:58:20 am THU 05-NOV-15 ENTRY 1 9:11:19 am THU 05-NOV-15 SYSTEM TIME/DATE INVALID OR NOT SET TROUBLE POINT ABNORMAL ENTRY 2 9:11:19 am THU 05-NOV-15 COLD START TROUBLE POINT ABNORMAL ENTRY 3 9:11:34 am THU 05-NOV-15 CARD 2, IDNET2 CARD IDNET FAULT SEARCH TROUBLE ENTRY 4 9:11:34 am THU 05-NOV-15 CARD 2, IDNET2 CARD IDNet CHANNEL INITIALIZATION TROUBLE ENTRY 5 9:11:36 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 6 9:11:39 am THU 05-NOV-15 LVL 3 PATIO 313 A1:2-6 AUDIBLE/VISUAL NO ANSWER ENTRY 7 9:11:40 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 8 9:11:50 am THU 05-NOV-15 PENTHOUSE MECH ACCESS 401 A1:2-14 AV WRONG DEVICE ENTRY 9 9:11: 52 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 10 9:12:22 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR NO ANSWER Service Port Page 2 Report 2 : Trouble Historical Log 11:58:21 am THU 05-NOV-15 ENTRY 11 9:12:22 am THU 05-NOV-15 MEZZ CELL DIALER TROUBLE M1-42 TROUBLE MONITOR NO ANSWER ENTRY 12 9:12:23 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 13 9:13:16 am THU 05-NOV-15 PENTHOUSE MECH ACCESS 401 A1:2-14 AV NO ANSWER ENTRY 14 9:13:19 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 15 9:25:44 am THU 05-NOV-15 LVL 2 LOBBY 217 Al-10 AUDIBLE/VISUAL NO ANSWER ENTRY 16 9:25:48 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 17 9:26:27 am THU 05-NOV-15 LEVEL=3 AT MAIN PANEL BY OPERATOR 3 ENTRY 18 9:26:28 am THU 05-NOV-15 SIGNAL BYPASS SUPERVISORY POINT ABNORMAL ENTRY 19 9:26:29 am THU 05-NOV-15 ELEVATOR RECALL BYPASS SUPERVISORY POINT ABNORMAL ENTRY 20 9:26:29 am THU 05-NOV-15 HVAC/FSD CONTROL BYPASS SUPERVISORY POINT ABNORMAL ENTRY 21 9:26:30 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL Service Port Page 3 Report 2 : Trouble Historical Log 11:58:22 am THU 05-NOV-15 ENTRY 22 9:29:34 am THU 05-NOV-15 MEZZ EQUIP RM 114 AHU-4 M1-3 DUCT DETECTOR TEST ABNORMAL ENTRY 23 9:29:36 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 24 9:32:04 am THU 05-NOV-15 LVL 2 CLASSROOM 202 Al-11 STROBE NO ANSWER ENTRY 25 9:32:04 am THU 05-NOV-15 LVL 2 TOILET 2B 217 A1-12 STROBE NO ANSWER ENTRY 26 9:32:04 am THU 05-NOV-15 LVL 2 TOILET 2A 214 A1-13 STROBE NO ANSWER ENTRY 27 9:32:04 am THU 05-NOV-15 LVL 2 LAUNDRY 203 A1-14 STROBE NO ANSWER ENTRY 28 9:32:04 am THU 05-NOV-15 LVL2 GEAR UP 204 Al-15 AUDIBLE/VISUAL NO ANSWER ENTRY 29 9:32:08 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 30 9:33:48 am THU 05-NOV-15 CARD 1, EXTENDED SYSTEM SUPPLY Page 1 TroubleLog_2015_11_5.txt IDNAC 1 Short Circuit TROUBLE ENTRY 31 9:39:06 am THU 05-NOV-15 LVL 1 STAIR 3 105 WF/TAMPER M1-10 SPRINKLER MONITOR ABNORMAL Service Port Page 4 Report 2 : Trouble Historical Log 11:58:23 am THU 05-NOV-15 ENTRY 32 9:39:09 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 33 9:41:02 am THU 05-NOV-15 SIGNAL BYPASS SUPERVISORY POINT ABNORMAL ENTRY 34 9:41:04 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 35 9:41:55 am THU 05-NOV-15 LVL 1 RISER RM 115 WF/TAMPER M1-11 SPRINKLER MONITOR ABNORMAL ENTRY 36 9:41:57 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 37 9:42:09 am THU 05-NOV-1S LVL 1 RISER RM 115 WF/TAMPER M1-11 SPRINKLER MONITOR ABNORMAL ENTRY 38 9:42:11 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 39 9:43:29 am THU 05-NOV-15 LVL 1 STAIR2 SPRINK RISER M1-41 SPRINKLER MONITOR ABNORMAL ENTRY 40 9:43:36 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 41 9:44:54 am THU 05-NOV-15 LVL 2 STAIR 206 WF/TAMPER M1-18 SPRINKLER MONITOR ABNORMAL ENTRY 42 9:44: 59 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 43 9:45: 56 am THU 05-NOV-15 LVL 3 STAIR 3 306 WF/TAMPER M1-26 SPRINKLER MONITOR ABNORMAL Service Port Page 5 Report 2 : Trouble Historical Log 11:58:24 am THU 05-NOV-15 ENTRY 44 9:46:00 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 45 9:46:53 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 46 9:46:55 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 47 9:51:02 am THU 05-NOV-15 PENTHOUSE MECH ACCESS M1-33 SPRINKLER MONITOR ABNORMAL ENTRY 48 9:52:08 am THU 05-NOV-15 ELEVATOR RECALL BYPASS SUPERVISORY POINT ABNORMAL ENTRY 49 9:52:08 am THU 05-NOV-15 HVAC/FSD CONTROL BYPASS SUPERVISORY POINT ABNORMAL ENTRY 50 9: 52:09 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 51 9:53:00 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR OPEN CKT TROUBLE ENTRY 52 9:53:01 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 53 9:53:06 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 54 9:53:08 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL Service Port Page 6 Report 2 : Trouble Historical Log 11:58:24 am THU 05-NOV-15 ENTRY 55 9: 54:40 am THU 05-NOV-1S OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR OPEN CKT TROUBLE ENTRY 56 9:54:42 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 57 9:54:44 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR OPEN CKT TROUBLE ENTRY 58 9:54:45 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 59 9:54:54 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 60 9:54:56 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL Page 2 TroubleLog_2015_11_5.txt ENTRY 61 9: 55:28 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR OPEN CKT TROUBLE ENTRY 62 9:55:30 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 63 9:55:46 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 64 9:55:48 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 65 9:56:46 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR OPEN CKT TROUBLE Service Port Page 7 Report 2 : Trouble Historical Log 11:58:25 am THU 05-NOV-15 ENTRY 66 9:56:49 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 67 9:57:00 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 68 9: 57:04 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 69 9:57:04 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 70 9: 57:06 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 71 9:57:07 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 72 9:58:00 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 73 9:58:01 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 74 9:58:04 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 75 9:58:04 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR OPEN CKT TROUBLE ENTRY 76 9:58:07 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL Service Port Page 8 Report 2 : Trouble Historical Log 11:58:26 am THU 05-NOV-15 ENTRY 77 9:58:24 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 78 9:58:29 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 79 9:59:36 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR OPEN CKT TROUBLE ENTRY 80 9:59:43 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 81 10:00: 58 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR OPEN CKT TROUBLE ENTRY 82 10:01:04 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 83 10:03:36 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 84 10:03:39 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 85 10:03:42 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR OPEN CKT TROUBLE ENTRY 86 10:03:46 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 87 10:09:44 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR OPEN CKT TROUBLE ENTRY 88 10:09:46 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL Service Port Page 9 Report 2 : Trouble Historical Log 11:58:27 am THU 05-Nov-15 ENTRY 89 10:10:32 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 90 10:10:34 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 91 10:10:44 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL Page 3 TroubleLog_2015_11_5.txt ENTRY 92 10:10:46 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 93 10:11:16 am THU 05-NOV-15 MEZZ EQUIP RM 114 AHU-4 M1-3 DUCT DETECTOR TEST ABNORMAL ENTRY 94 10:11:17 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 95 10:11:18 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 96 10:11:57 am THU 05-NOV-15 MEZZ EQUIP RM 114 AHU1-3 M1-2 DUCT DETECTOR TEST ABNORMAL ENTRY 97 10:11:58 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 98 10:12:25 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 99 10:12:27 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL Service Port Page 10 Report 2 : Trouble Historical Log 11:58:28 am THU 05-NOV-15 ENTRY 100 10:12:29 am THU 05-NOV-15 HVAC/FSD CONTROL BYPASS SUPERVISORY POINT ABNORMAL ENTRY 101 10:12:30 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 102 10:12:39 am THU 05-NOV-15 OUTSIDE VAULT TAMPER M1-34 SPRINKLER MONITOR ABNORMAL ENTRY 103 10:12:41 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 104 10:23:53 am THU 05-NOV-15 LEVEL=1 AT MAIN PANEL BY OPERATOR 1 ENTRY 105 10:29:18 am THU 05-NOV-15 LVL 1 FLEX RM 1 109 AHU-2 M1-5 DUCT DETECTOR TEST ABNORMAL ENTRY 106 10:29:20 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 107 10:29:48 am THU 05-NOV-15 LEVEL=3 AT MAIN PANEL BY OPERATOR 3 ENTRY 108 10:31:24 am THU 05-NOV-15 LVL 1 FLEX RM 1 109 AHU-2 M1-5 DUCT DETECTOR TEST ABNORMAL ENTRY 109 10:31:27 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 110 10:33:55 am THU 05-NOV-15 LVL 1 CASH RM 103 AHU-1 M1-8 DUCT DETECTOR TEST ABNORMAL ENTRY 111 10:33:57 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL Service Port Page 11 Report 2 : Trouble Historical Log 11:58:28 am THU 05-NOV-15 ENTRY 112 10:36:26 am THU 05-NOV-15 LVL 3 MANAGER 303 AHU3-2 M1-27 DUCT DETECTOR NO ANSWER ENTRY 113 10:36:31 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 114 10:48:54 am THU 05-NOV-15 LVL 2 VIP 210 AHU2-3 M1-12 DUCT DETECTOR TEST ABNORMAL ENTRY 115 10:48:56 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 116 10:56:55 am THU 05-NOV-15 LVL 2 VIP 210 AHU2-4 M1-13 DUCT DETECTOR TEST ABNORMAL ENTRY 117 10:56:58 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 118 10:57:47 am THU 05-NOV-15 LVL 3 MANAGER 303 AHU3-2 M1-27 DUCT DETECTOR NO ANSWER ENTRY 119 10:57:50 am THU 05-NOV-15 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 120 11:00:41 am THU 05-NOV-15 LVL 2 VIP 210 AHU2-4 M1-13 DUCT DETECTOR TEST ABNORMAL ENTRY 121 11:00:43 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 122 11:10:58 am THU 05-Nov-15 LVL 2 CLASSROOM 202 AHU2-5 M1-15 DUCT DETECTOR TEST ABNORMAL ENTRY 123 11:11:03 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL Service Port Page 12 Report 2 : Trouble Historical Log 11:58:29 am THU 05-NOV-15 ENTRY 124 11:11:37 am THU 05-NOV-15 LVL 2 CLASSROOM 202 AHU2-2 M1-16 Page 4 TroubleLog_2015_1L5.txt DUCT DETECTOR TEST ABNORMAL ENTRY 125 11:11:40 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 126 11:23:12 am THU 05-NOV-15 LEVEL=1 AT MAIN PANEL BY OPERATOR 1 ENTRY 127 11:23:14 am THU 05-NOV-15 LVL 2 LAUNDRY 203 AHU2-1 M1-17 DUCT DETECTOR TEST ABNORMAL ENTRY 128 11:23:18 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 129 11:30:27 am THU 05-NOV-15 LVL 3 STORAGE 314 AHU3-3 M1-40 DUCT DETECTOR TEST ABNORMAL ENTRY 130 11:30:30 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 131 11:35:26 am THU 05-NOV-15 LVL 3 STORAGE 314 AHU3-3 M1-40 DUCT DETECTOR TEST ABNORMAL ENTRY 132 11:35:28 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 133 11:41:24 am THU 05-NOV-15 LVL 3 MANAGER 303 AHU3-2 M1-27 DUCT DETECTOR TEST ABNORMAL ENTRY 134 11:41:28 am THU 05-N0V-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 135 11:45:15 am THU 05-NOV-15 LVL 3 CEO 302 AHU3-1 M1-28 DUCT DETECTOR TEST ABNORMAL Service Port Page 13 Report 2 : Trouble Historical Log 11:58:30 am THU 05-NOV-15 ENTRY 136 11:45:17 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL ENTRY 137 11:48:38 am THU 05-NOV-15 PENTHOUSE MECH ACCCESS 401 AHU4-1 M1-32 DUCT DETECTOR TEST ABNORMAL ENTRY 138 11:48:44 am THU 05-NOV-15 SUPERVISORIES ACKNOWLEDGED AT MAIN PANEL TROUBLE HISTORICAL LOG REPORT COMPLETED Page 5