Specifications A4Ee IolS-ooG?l 56l1SwGfJce-s 203 • MITSUBISHI ELECTRIC _sER1Es C O O L I N G & H E A T I N G SUBMITTAL DATA SLZ-KAO9NA &SUZ KAO9NA <. 9 t)OO BTU/H CEILING CASSETTE HEAT PUMP SYSTEMS Job Name: Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference ElApproval ElConstruction System Designation: Schedule No.: - ECEIVED 0 //- t, Ali !1 , I1lij 1 OCT 8 2015 41 I E it j CIIIVOFTIGARD ,mot BUILDING DIVISION Indoor Unit SLZ-KAO9NA Outdoor Unit SUZ-KA09NA GENERAL FEATURES f • Four-way 25x2'ceiling-cassette indoor unit for ceiling recessed applications • Built-in drain mechanism for condensate removal,lifts to 19-11/16" • Wide air-flow pattern for better air distribution • Design features ventilation air intake knockout • Long-life air filter included with indoor unit • Indoor unit powered from outdoor unit using A-Control • Choice of fan speed Low,Medium,High • Automatic restart following a power outage • Limited warranty five years parts and seven years compressors ACCESSORIES Indoor Unit ❑ Grille(SLP-15AAUW;required-shipped with unit) ❑ Outdoor Unit ❑ Drain Pan Heater(MAC-640BH-U) ❑ Drain Socket(MAC-860DS) ❑ Three-pole Disconnect Switch(TAZ-MS303) ❑ Air Outlet Guide(MAC-856SG) ❑ Mounting Base(DSD-400N) ❑ Mounting Pad(ULTRILITE1) Controller Options ❑ Wireless Wall-mounted Remote Controller Kit(MHK1)* ❑ Portable Central Controller(MCCH1)* ❑ Outdoor Air Sensor(MOS1)* ❑ Wired Wall-mounted Controller(PAR-31 MAA)* ❑ Simple MA Remote Controller(PAC-YT53CRAU)' *See Submittal for information on each option. ❑ Remote Temperature Sensor(M21-JKO-307) ❑ Hand-held Wireless Remote Controller (PAR-FL32MA,req PAR-FA32MA-E) ❑ Wireless Signal Receiver PAR-FA32MA(for PAR-FL32MA) ❑ Lockdown Bracket for Hand-held Controller(RCMKP1CB) .QA I N ER R Specifications are subject to change without notice f ©2013 Mitsubishi Electric US,Inc I C. SPECIFICATIONS SLZKA09NA'&SUZ KA09Nk.' .LL Cooling* Indoor Unit Rated Capacity . . . 8,400 Btu/h MCA . . 1 A Minimum to Maximum Capacity Range . .. . ...3,100-10,900 Btu/h Fan Motor Output . .. 15 W SEER . .. . . . . . . .. . . . . . 15 0 Btu/h/W Fan Motor(ECM) . . . . .. . . . . . .. . . .0.23 F.L A EER . . 12 0 Btu/h/W Airflow(Lo-Med-Hi) . . 280.-320-350 Dry CFM Total Input . . 700 W 250-290-320 Wet CFM Heating at 47°F* Air Filter . . .. . .. Polypropylene Honeycomb Rated Capacity 10,900 Btu/h Sound Pressure Level(Lo-Med-Hi) . 29-32-38 dB(A) Minimum to Maximum Capacity Range . . 3,100-14,100 Btu/h DIMENSIONS UNIT INCHES/MM GRILLE INCHES/MM HSPF . . . . . . . .. .. 9 6 Btu/h/W W 22.7/16/570 25-5/8/650 COP . .. . . . 3.44 Total Input. . . . . . . . . . . 930 W D 22-7/16/570 25-5/8/650 Heating at 17°F* H 9-1/4/235 _13/16/20 Rated Capacity .. . . . . . .. 6,200 Btu/h Weight(Unit/Grille) Rated Total Input . . . . .. . . ... . 740 W Lbs. 36/7 COP . . . .. . .. . .2 46 Maximum Capacity** .. 6,200 Btu/h Eternal Finish(Unit/Grille) Galvanized-steel Sheets 3/ Maximum Total Input . . ... . 1,040 W Munsell 6 4Y 8 9/0 4 Field Drainpipe Size 0 D. . .1-1/4"/32 mm *Rating Conditions per AHRI Standard Cooling I Indoor 80°F(27°C)DB/67°F(19°C)WB Outdoor Unit Cooling I Outdoor 95°F(35°C)DB/75°F(24°C)WB Compressor DC Inverter-driven Heating at 47°F I Indoor.70°F(21°C)DB/60°F(16°C)WB MCA. .. . . . .. . .12 A Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)WB MOCP .. . . .. .. .. . 15 A Heating at 17°F I Indoor:70°F(21°C)DB/60°F(16°C)WB Fan Motor(ECM) .. 0.50 F L A. Heating at 17°F I Outdoor 17°F(-8°C)DB/15°F(-9°C)WB Sound Pressure Level Cooling .. ... . .. . . . . 46 dB(A) **Maximum Capacity is at full speed and performance for Heating . . 50 dB(A) INVERTER-driven System. DIMENSIONS INCHES/MM ] W 31-1/2/800 D 11-1/4/285 Electrical Requirements H 21-5/8/550 Power Supply 208/230V, 1-Phase,60 Hz i Recommended Fuse/Breaker Size . . . .15 A Weight 66 lbs /30 kg Voltage External Finish Munsell No.3Y 7 8/1 1 Indoor-Outdoor S1-S2 . .AC 208/230V Refrigerant Type . . . .. .R410A Indoor-Outdoor S2-S3 . . . DC±24V Refrigerant Pipe Size 0 D. Gas Side . . .. 3/8"/9 52 mm Liquid Side . .. .1/4"/6 35 mm OPERATING CONDITIONS Max.Refrigerant Pipe Length . .. .. .. 65'/19 m Indoor Intake Air Outdoor Intake Air Max.Refrigerant Pipe Height Difference . 40'/12 m Connection Method .. . . . . Flared Temp. Temp. -Maximum 95°F(35°C)DB 115°F(46°C)DB Cooling 71°F(22°C)WB Minimum 67°F(19°C)DB 14°F(-10°C)DB 57°F(14°C)WB Maximum 80°F(27°C)DB 75°F(24°C)DB Heating • 67°F(19°C)WB 65°F(18°C)WB Minimum 70°F(21°C)DB -4°F(-20°C)DB 60°F(16°C)WB -5°F(-21°C)WB Notes Specifications are subject to change without notice ©2013 Mitsubishi Electric US,Inc i�� �w� ��� "", � r w, 4�*�� �F 7"�` z 4 �"�1zej�avt' e: +t�i�''''' w -; � r {� f , � DIMENSIONS �SLIZ=KA09NAt •,� --,, '4 ;. ' <,. ,€ ,t*V. ' 1,4:3 .,, . ,r. .< ro Vi, =1., ° i f�� � -'' . x'z -1 ; i''', , .,''r':'„3 ,y ;`''''' Unit: inch (mm) 1 r , r Fresh air I Detail drawing of fresh air intake ., intake ti N t `�� I �. g3-15n6(g100) 1(25) ► \ / �, 02-7/8(073 4) 3-01/8(02 8 � g �\ 20-7/8(530) /' 8) Cut out hole \$uspensio(i bolt pitch/ Burring hole ll N C M N W ) M r M - M N / ` ,_ O \ • N p N N N I I r:, °1 r'n /2-7/16k570) ` o �0. M ` / \ -m- N i c� r m �•�1i1 1111 Ceiling surface F, 3 I7-27/32(199) i V N • En 13-27/32(352) N A r 13-3/16(335) , 19/32-1-15/32(15-37) 22-11/16-24-13/32(576-620) Ceiling hole 19/32-1-15/32(15-37) Drain pipe Winng entry m VP-25 connection co Refrierant 21/32(17) 7-15/16 202 9-1/16(230) (O D 01-1/4(032)) g M pipe(gas) ' I Suspension bolt M10 or W3/t `�� li !r r' Refngeranl ;11 - 7I� I�� �, pipe squid) ;11—e-R :I11 112) I 1 Mil 11 rn n Iii lei — — — � �r∎L . _ N m ° Terminal block Grille M 0 Ceiling surface v N M E. roo zil W '''13, / N ,- av i N ,8 N �_ Models Refngerent pipe Refngerent pipe 25-19/32(650) (liquid) (gas) m 11-27/32(301) 1/4 inch 3/8 inch Air outlet hole Brand label SLZ-KAO9NA (0 6 35mm) (0 9 52mm) r/Grille flared connection flared connection in 'YiM'-18 4' Drain hole 1/4 inch 3/8 inch N SLZ-KAl2NA (0 6 35mm) (0 9 52mm) 1, — - non flared connection flared connection Auto vane I. MI / 6 inch 1/2 inch o SLZ-KA15NA (0 6 35mm) (0 12 7mm) Mrn N H = flared connection flared connection L 7 0 c O " ` IEU! _ __. '0� Air intake grille -Vane motor 14-27/32(377) Air intake hole 1-3/8(35) 2-5/32(55) Specifications are subject to change without notice ©2013 Mitsubishi Electric US,Inc r :","'""o DIME,tsita s SUZ , < 09.16 y , `: b &',. 4';',... - °/",' `mss; 9 15-3/4 Drain hole 951-5/8 Unit: inch cl 0 Air in , NA _ - 1 M N Air In b 1 rn N �'L 1-9/16 V Air Out 2-3/8 x 13/16 Oval hole 7/8_ 29/32 11-1/4 .17/32 . 29/32 a handle /re 111111111111111111111111111111111111111111 1 I'� 1 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII N M IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 13 N ���� Liquid pipe 1/4(flared) IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII °$—� °O °' 1 Gas pipe :3/8(flared)(KA09/12) ,f,, _ 1/2(flared)(KA15) M 11-29/32 6-23/32 1 5-15/16 19-11/16 31-1/2 2-23/32 REQUIRED SPACE Basically open 4 inch or more without any obstruction in front and on both sides of the unit. oye &V`'°` 4,•,7 or ■ 80.°` C>11411 ►►ft ore Open two sides of lef t, right,or rear side. MITSUBISHI ELECTRIC A����� C E R T i F i E�v. E N E R G Y IAR C O O L I N G & H E A T I N G www.ahrPolrectgrv.nrg ; PARTNER Live Better Unitarysmai HPw r ' AHHIStandard210/240, ,, ,, US 1340 Satellite Boulevard t dlopp pPL1 N nlm ryleGk 1 tee M L (ISTEO Suwanee,GA 30024 Tele 678-376-2900•Fax 800-889-9904 Intertek Toll Free 800-433-4822 www mehvac corn FORM#SLZ-KAO9NA-SUZ-KAO9NA-201311 Specifications are subject to change without notice ©2013 Mitsubishi Electric US,Inc ■i�—,it IC COOLING & HEATING M® and P-SERIES Model: PAR-31 MAA Job Name: Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: -- ----—--- - BACKLIT MA REMOTE CONTROLLER(PAR-31 MAA) F .L MITSUBISHI ELECTRIC SPECIFICATIONS • Controls group operation for up to 16 indoor units in a single group 1 14:30 Fn g • Features selectable multi-lingual LCD(English, Spanish,and e O a 4 Oa �,i French) o�g . Room 2$°C a • Supports both Fahrenheit and Celsius Q • User functions allow user to set Cool Set temp. Auto -On/Off 28.c x o -Operation modes cool, heat,dry,fan -Set temperature -Fan speed setting Airflow direction {' - i II I • Timer Operation: [ -Weekly Timer On/Off/Temperature setting up to 8 times per day of the week in 1-minute increments • -Simple Timer On and Off time can be set once within 72-hour g ) 01, V\ period in 1-hour increments -Auto-off Timer Turns indoor unit Off based on countdown time up to 4-hours in 30-minute increments • Room Temperature Displays room temperature sensed either at the indoor unit(default)or at the remote controller • Set Temperature Range Limit: From the Backlit MA Controller,the allowable set temperature range can be reduced for cool and heat modes • Special Function Rotation/Backup(Lead/Lag for P-Series) • Static pressure setting(model dependent) • Fan speed setting for use with supplemental heating function (model dependent) • Set P-Series twinning function • Function Lock Out Prohibits all functions or all functions except On/Off from the backlit MA controller • Addressing No addressing required • Wiring connects using two-wire,stranded,non-polar control wire to indoor unit connection terminal or control adapter(MAC-3331F for M-Series)requires crossover wiring for indoor unit grouping • Dimensions 4-3/4 x 3/4 x 4-3/4"(120 x 19 x 120 mm) Notes Specifications are subject to change without notice ©2013 Mitsubishi Electric US.Inc Model: PAR-31 MAA - DIMENSIONS Unit:mm[in.] • (Front view) (Side view) (Rear view) 46[1-13/16 120[4-3/4] 19[3/4] N M V M M V 4' U7 N i � CO CO 0000 a Ft JU I SUBISH 1340 Satellite Boulevard ELECTRIC Tele'678-376-29004•Fax.800-889-9904 FORM#PAR-31 MAA-201309 Toll Free'800-433-4822 Specifications are subject to change without notice. COOLING & HEATING www mehvac corn ©2013 Mitsubishi Electric US,Inc Live Better