Loading...
Report F .2O IS' 00 1S`d ti teeo sw 72 Metro Safety & Fire 14324 SE Stark Street; Portland, Oregon 97233 PHONE (503) 231-2999 CCB#63651 UPS Distribution Center 14160 SW 72nd Avenue Tigard, Oregon PROpe C.? �NGINEF9 4(2 12089PE "57r 0,/th". Clh4P'%'- OREGON <4 '(/)' 20, Ago� /qN C 5 EXPIRES: 12/31/2016 FIRE PROTECTION EQUIPMENT SUBMITTAL UPS Distribution Center 14160 SW 72nd Avenue Tigard, Oregon FIRE PROTECTION EQUIPMENT SUBMITTAL INDEX PRODUCT MAKE MODEL I DESCRIPTION 1. SPRINKLERS GLOBE Model GL ELO Storage Upright SIN#GL1167 Bronze Finish 2. PIPING BULLMOOOSE TUBE Black Steel, Schedule 10,ASTM A795 3. PIPE FITTINGS SMITH COOPER Ductile Iron, Grooved,ASTM A536 4. HANGERS COOPER B-LINE Figure 2NFPA Band Hanger Ring COOPER B-LINE Figure ATR All Thread Rod COOPER B-LINE Figure 65 C-Type Beam Clamp COOPER B-LINE Figure 69 Retainer Strap 5. SEISMIC BRACING TOLCO Model 4L Seismic Clamp TOLCO Model 1001 Fast Clamp TOLCO Model 980 Seismic Attachment **The above listed items are the proposed equipment to be used on this project, however we reserve the right to use an 'equivalent'product or manufacturer at our discretion. MODEL GL1167 • 412o\ EXTRA LARGE ORIFICE • AUTOMATIC SPRINKLERS FIRE SPRINKLER CORPORATION FOR USE IN NFPA 13 231, 231C DESCRIPTION AND OPERATION 231D & 231 F SYSTEMS The Globe Model GL1167 Extra Large Orifice Upright Sprinkler is intended for use in NFPA 13, 231, 231C, 231 D and 231 F Systems,when installed in accordance with the Standard Sprinkler Positioning and area/density flow calculation requirements as specified in each respec- tive standard. When acceptable to the Authority having Jurisdiction the Model GL1167 Sprinkler may be used as a"special application"sprinkler when installed to protect single, double and multiple-row and portable rack storage of Class I - IV group A and B plastics, cartoned, expanded or unexpanded, as well as exposed unexpanded with a maximum storage height of 20 feet, maximum ceiling height of 25 feet, 36 inches it minimum deflector to top of storage clearance, design density of 0.60 gpm/sq. ft., and a design area of 2,000 sq. ft. for wet systems or 2,600 sq. ft. for dry systems. The Model GL1167 Sprinkler is a low profile yet durable design which utilizes a 5mm frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it serves to protect various area coverages. This sprinkler series is available in the upright style and several temperature ratings and finishes to meet varying design requirements. The heart of Globe's Model GL1167 sprinkler proven actuating UPRIGHT assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the pre- scribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Rating - 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C). • Water Working Pressure Rating - 175 psi (12 Bars). • Minimum Operating Pressure - 10 psi (0.7 Bars). • Factory tested hydrostatically to 500 psi (34 Bars). • Maximum low temperature glass bulb rating is -67°F (-55°C). • Frame - bronze • Deflector - brass • Screw - brass • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with glycerin solution, 5mm size. • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A.MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 155°F 68°C RED 100°F 38°C INTERMED IATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C HIGH 286°F 141°C BLUE 225°F 107°C 4077 Al RPARK DRIVE,STANDISH,MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 AUGUST2002 A-82 BULLETIN GL1167,REV #1 MODEL GL1167 • EXTRA LARGE ORIFICE A UTOMATIC SPRINKLERS FOR USE IN NFPA 13, 231C 1 231D & 231F SYSTEMS SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES Factory Bronze Satin Chrome' 11.5 (166 metric) 3/4" NPT 2 7/16" (6 19 cm) Bright Chrome White Polyester2 Black Polyester2 Lead Coated' NOTE: 'Finishes available on special order. Metric Conversions are approximate. 2Available as cULus listed corrosion resistant when specified on order. APPROVALS SIN K 155°F I75°F 200°F 286°F NYC-DOB STYLE MODEL FACTOR 68°C 79°C 93°C 14I°C cULus MEA I0I-92-E UPRIGHT GL1167 11.5 X X X X X X ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured products found to be defective in mate- •Quantity • Model Number • Style real or workmanship for a period of one year from date •Orifice • Temperature • Finishes desired of shipment •Quantity-Wrenches- P/N 333010 For specific details of our warranty please refer to Price List Terms and Conditions of Sale(Our Price List). GL • 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 FIRE SPRINKLER CORPORATION 989-846-4583 FAX 989-846-9231 1-800-248-0278 www globesprinkler.com AUGUST 2002 PRINTED U.S A BULLETIN GL1167, REV #1 Schedule 10 and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. other fine pipe products. Schedule 10 Pipe Nominal Pipe Size O.D. I.D. ! Nom.Wall Weight/Ft Bundle • (in) (in) (in) (in) Size 1 1.315 1.097 0.109 1.40 lbs/ft 61 1-1/4 1.660 1.442 0.109 1.81 lbs/ft 37 1-1/2 1.900 1.682 0.109 2.08 lbs/ft 37 2 2.375 2.157 0.109 2.64 lbs/ft 37 2-1/2 2.875 2.635 0.120 3.53 lbs/ft 37 3 3.500 3.260 0.120 4.33 lbs/ft 24 4 4.500 4.260 0.120 5.62 lbs/ft 19 Schedule 40 Pipe Nominal Pipe Size O.D. I.D. Nom. Wall Weight/Ft Bundle (in) (in) (in) (in) Size 1 1.315 1.049 0.133 1.68 lbs/ft 61 1-1/4 1.660 1.380 0.140 2.27 lbs/ft 37 1-1/2 1.900 1.610 0.145 2.72 lbs/ft 37 2 2.375 2.067 0.154 3.65 lbs/ft 37 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, A Chesterfield,MO 63017 contact your salesperson today at c L us LW� II BULL MOOSE TUBE CANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED --7--- -- FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 41> AL A O company e-mail info(bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication But Moose Tube reserves the nght to change product specifications without notice and without incurring obligation 06/01 SMITHCOOPER® I N T E R N A T I O N A L CORPORATE OFFICE TEL(800)766-0076 LOCAL(323) 890-4455 FAX (323)890-4456 W W W.SMITH000PER.COM .: .t om ,' a. k ' , � fs``1 .4 ' Z t ty ; A of sT t E • '` . ,r w....f&.^ f• ~yam.. �w.`° '� l•+• +,yice�" J .�,. 11 # / : : �,- // > '14 j /, / 4 ftj v AI 0OPO ff o v Grooved Couplings & Fittings SMITHCOOPER® I N T E R N A T I O N A L• GROOVED COUPLINGS & FITTINGS TABLE OF CONTENTS Lightweight Couplings 1-2 Concentric Reducers & Reducing Tees 10 Standard Weight Couplings 3-4 Threaded Mechanical Tees 11-12 Reducing Couplings 5 Grooved Mechanical Tees 13 Hinged Flange Adapters 6 Strap Tees 14 Short Radius Fittings 7 Adapter Elbow 15 Drain Cap 7 COOPLET® Adapter Nipples. 16 Drain Elbow 7 Standard Roll Groove Specifications 17 Standard Radius Elbows 8 Standard Cut Groove Specifications 18 Tee 9 UL Listed/FM Approved Sprinkler Pipe • Cross 9 and Warranty Information 19 Caps 9 Installation Instructions 20 Grooved x Flange Adapter 9 Housing •Ductile Iron Conforming to ASTM A536 Coating •Orange Paint • Hot Dipped Galvanized Conforming to ASTM A153 Hardware •Electroplated Track Bolts Conforming to ASTM A183 • with a minimum tensile strength of 110,000 psi • 100%Magnetic Particle Inspection of Each Bolt Gaskets •Grade E EPDM(Green Stripe) • Temperature Range:—30°F(-34°C)to+230°F(+110°C) • •Grade T Nitrite(Orange Stripe) Temperature Range:—20°F(-29°C)to+180°F(+82°C) Grooves •Dimensions to AWWA C606 All COOPLOKT"'Grooved products CO Us UL Listed and FM Approved. LISTED APPROVED SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4436 • www.smithcooper.com {{��',€ F . � 500 Series Lightweight Flexible Couplings • k: 1 , _ ____ _ - .,- *,, ;, /re-" 1 1001 Iv 1 �1 a 000S 1i? IGeill IT A A „, IUIII I A , ■ , , _ s -...„„,„,„„,,,..„,60,, ,,-.," APPROVED 101 sa■Lilmiew 0 -.;:".' -- 1a1 Fig. 65LF& 66LF-Lightweight Flexible Couplings C B Part Number Max Pipe Max Working . Dimensions Pipe Size Pipe OD End Gap Pressure A B C Bolt Size Deflection Weight Painted Galv IN/mm IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm IN/mm Degrees LB/kg 1-1/4 1.66 1/8 500 2.58 4 09 1.85 3/8" x 2 1 2 651/3012 661/3012 2 1° 32 42.2 3.2 34.5 65.5 103.9 47.0 M10 x 52 0.5 1-1/2 1 900 1/8 500 2.85 4 37 1.85 3/8" x 2 1 3 65113014 66113014 1.9° 40 48.3 3.2 34.5 72.4 111.0 47.0 M10 x 52 0.6 ' 2 2.375 1/8 500 3.37 4 8 1.85 3/8" x 2-1/2 1.7 651/3020 66113020 2 0° 50 60.3 3.2 34.5 85.6 121.9 47.0 M10 x 60 0.8 2-1/2 2 875 1/8 500 3 88 5.28 1 85 3/8"x 2-1/2 1.9 • 65113024 661/3024 2.3° 65 73.0 3.2 34.5 98.6 134.1 47.0 M10 x 65 0.9 3 3 500 1/8 500 4 4 5.91 1 85 3/8"x2-1/2 2.1 65113030 661/3030 2.0° 80 88.9 3 2 34.5 111 8 150.1 47.0 M10 x 65 0.9 4 4 500 1/4 500 5.75 7 44 2.01 1/2" x 3-1/4 3 6 65113040 66113040 2 2° 100 114.3 6.4 34.5 146.1 189.0 51.1 M12 x 80 1.6 5 5 563 1/4 500 6 79 9.13 2.01 5/8"x 3-3/4 5 1 65113050 661/3050 1 8° 125 141.3 6.4 34.5 172.5 231.9 51.1 M16 X 95 2 3 6 6.625 1/4 500 7.95 10 31 2 01 5/8"x 3-3/4 6 0 651/3060 661/3060 1 6° 150 168.3 6.4 34.5 201.9 261.9 51.1 M16 X 95 2.7 65113080 66113080 8 8 625 1/4 500 10 8 13 07 2 52 3/4" X 5-1/4 1 4° 10.6 200 219.1 6.4 34.5 274.3 332.0 64.0 M19 X 110 4.8 NOTES: 1. All bolts and gaskets identified by SCI logo. 2. 100% Magnetic particle inspection of each bolt. Each bolt has a minimum tensile strength of 110,000 psi. 3. Gaskets are pre-lubricated. 4. Gasket Grade E EPOM(green stripe): • Temperature range:-30°F(-34°C) to+230°F(+110°C). 5. Gasket Grade T Nitrite(orange stripe): • Temperature range:-20°F(-29°C) to+180°F(+82°C). _ 6. See Installation Instructions on Page 20. 7. SMITH-COOPER Warranty(see page 19) only applies to assemblies made up using gaskets, housings, and bolts with the CI logo. c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.sminccooper.com 1 f:0. I -; 500 Series Lightweight Rigid Couplings .G1 ,t -1� B • ��c us � j d �� .. ® ,.. pig- � APPROVED will I III L____" I C Fig. 65LR & 66LR-Lightweight Rigid Couplings Part Number Max Pipe Max Working Dimensions Pipe Size Pipe OD End Gap Pressure A B C Bolt Size Weight Painted Galv IN/mm IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm IN/mm LB/kg 1-1/4 1.660 1/8 500 2.66 4 09 1.85 3/8" x 2 1.2 85L113012 66118012 32 42.2 3.2 34.5 67.6 103.9 47.0 M10 x 52 0.5 1-1/2 1.900 1/8 500 2.93 4.37 1.85 3/8" x 2 1.3 65113014 66LR3014 40 48.3 3.2 34.5 74.4 111.0 47.0 M10 x 52 0.6 2 2 375 1/8 500 3 44 4.8 1 85 3/8"x2-1/2 1 7 65113020 86118020 50 60.3 3.2 34.5 87.4 121.9 47.0 M10 x 60 0.8 2-1/2 2.875 1/8 500 3.96 5.28 1.85 3/8"x 2-3/4 1 9 851R3024 66113024 65 73 0 3.2 34.5 100.6 134.1 47.0 M10 x 65 0.9 3 3 500 1/8 500 4.55 5.91 1.85 3/8"x 2-3/4 2.1 65113030 66113030 80 88.9 3.2 34.5 115.6 150.1 47.0 M10 x 65 1.0 4 4.500 1/4 500 5 83 7.28 2.01 3/8"x 2-3/4 3.6 65113040 66118040 100 114.3 6.4 34.5 148.1 184.9 51.1 M10 x 65 1.6 5 5.563 1/4 500 6.87 8.62 2.01 1/2" x 3-3/4 5.1 65113050 66113050 125 141.3 6.4 34.5 174.5 218.9 51.1 M12x95 2.3 6 6 625 1/4 500 8 03 9 76 2 01 1/2"x 3-1/4 6.0 65113060 66113060 150 168.3 6.4 34.5 204.0 247.9 51.1 M12 x 95 2.7 8 8.625 1/4 500 10.16 12.52 2.52 5/8"x4-1/2 10.6 65118080 86113080 200 219.1 6.4 34 5 258.1 318.0 64.0 M16 x 120 4.8 NOTES: 1.All bolts and gaskets identified by SCI logo. 2. 100% Magnetic particle inspection of each bolt. Each bolt has a minimum tensile strength of 110,000 psi. 3. Gaskets are pre-lubricated. 4. Gasket Grade E EPDM(green stripe): • Temperature range:-30°F(-34°C)to+230°F(+110°C). - 5. Gasket Grade T Nitrile(orange stripe): • Temperature range: -20°F(-29°C)to+180°F(+82°C). 6. See Installation Instructions on Page 20. 7. SMITH-COOPER Warranty(see page 19) only applies to assemblies made up using gaskets, housings, and bolts with the CI logo. c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 2 c, i 500 Series Reducing Couplings . t B - 7/#"" .gr .,,c,;(.....A.0z -....04.--- . -,. c 0 us 111PA eu* 4. : Inli 1pi( 41 A �� APPROVED II!llhI p 0".• -4 7-,11577."-.., , 1.,-, ..i v• II '9Fr Er ■ . r Fig. 65RC& 66RC-Reducing Couplings Part Number Max Pipe Max Working Dimensions Pipe Size End Gap Pressure A B C Bolt Size Deflection Weight Painted GaIv IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm IN/mm Degrees LB/kg 2 x 1-1/2 1/8 300 3.43 4.88 1.85 3/8x2-1/4 1 9 65E3020014 666C3020014 2 0° 50 x 40 3.2 20.7 87.1 124.0 47.0 M10 x 57 0.9 65RC3024020 66E3024020 2-1/2 x 2 1/8 300 3 98 5 35 1.85 3/8 x 2-1/2 1 5° 2 3 65 x 50 3.2 20.7 101.1 135.9 47.0 M10 x 64 1.0 3 x 2 1/8 300 4 59 6.34 1 85 3/8x2-1/2 3.1 65RC3030020 66E3030020 1 8° 80x50 3.2 20.7 116.6 161.0 47.0 M10x64 1.4 3 x 2-1/2 1/8 300 4 51 6 34 1.85 3/8x2-1/2 2.9 65RC3030024 66RC8030024 1 8° 80 x 65 3.2 20.7 114.6 161.0 47.0 M10 x 64 1.3 4 x 2 1/4 300 5.83 7 52 2.01 1/2 x 3 4.8 65RC3040020 66RC8040020 1 2° 100x50 6.4 20.7 148.1 191.0 51.1 M12x76 2.2 4 x 2-1/2 1/4 300 5 83 7.52 2 01 1/2 x 3 4 8 65RC3040024 66RC3040024 1.2° 100x65 6.4 20.7 148.1 191.0 51.1 M12x76 2.2 4 x 3 1/4 300 5 83 7.52 2.01 1/2 x 3 4 4 65E3040030 66RC3040030 1.2° - 100 x 80 6.4 20.7 148.1 191.0 51.1 M12 x 76 2.0 65E3060040 66RC8060040 6 x 4 1/4 300 7 99 10.35 2 01 5/8 x 3-3/4 0 9° 9 150 x 100 6.4 20.7 202.9 262.9 51.1 M16 x 95 4.1 8 x 6 1/4 300 10 12 13.15 2 48 5/8 x 3-3/4 14 6 65E3080060 66RC3080060 0 8° 200 x 100 6.4 20.7 257.0 334.0 63.0 M19 x 108 6.6 NOTES: 1. All bolts and gaskets identified by SCI logo. 2. 100% Magnetic particle inspection of each bolt. Each bolt has a minimum tensile strength of 110,000 psi. 3. Gaskets are pre-lubricated. 4. Gasket Grade E EPDM(green stripe): • Temperature range:-30°F(-34°C) to+230°F(+110°C). - 5. Gasket Grade T Nitrite(orange stripe)available: • Temperature range:-20°F(-29°C) to+180°F(+82°C). . 6. See Installation Instructions on Page 20. 7. SMITH-COOPER Warranty(see page 19)only applies to assemblies made up using gaskets, housings, and bolts with the<>logo. c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • ww∎%.smithcooper.com 5 f t sOa � c,6 ti,4"'. ., 500 Series Hinged Flange Adapter 1 U 11k is ,t , _ 1. _./ ,:,..__ , . -„,-1::, .,_,,,,,: 4' Ill \ '''''''' ' ce0 us jr-__ _Fl i .„., ,... iwir . ,t, „,, 0_,„,-0 B ii � r � A � APPROVED s',° ` -- 4:21 i ....IF Fig. 65FH& 66FH-Hinged Flange Adapter Part Number Max Working Dimensions Flange Bolt Number Pipe Size Pipe OD Pressure A B C Size of Flange Weight Painted Galv IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm IN/mm Bolts LB/kg 2 2.375 300 6.00 4 75 0 75 5/8 x 3 3 6 65FH3020 66FH3020 4 50 60.3 20.7 152.4 120.7 19.1 M16 x 76 1.6 2-1/2 2 875 300 7 00 5.50 0.88 5/8 x 3 3.6 651/13024 66F118024 4 65 73.0 20.7 177.8 139.7 22.4 M16 x 76 1.6 3 3.500 300 7 50 6 00 0 94 5/8 x3 4 8 65FH3030 66FH3030 4 80 88.9 20.7 190.5 152.4 23.9 M16 x 76 2.2 4 4 500 300 900 750 094 5/8 x 3 66 65FH3040 661113040 8 100 114.3 20.7 228.6 190.5 23.9 M16 x 76 3.0 6 6.625 300 11.00 9 50 1.00 3/4 x 3-1/2 8 4 65FH3080 66FH3060 8 150 168.3 20.7 279,4 241.3 25.4 M19 x 89 3.8 8 , 8 625 300 13.50 11 75 1 12 3/4 x 3-1/2 14 3 651i13080 661113080 8 200 219.1 20.7 342.9 298.5 28.4 M 19 x 89 6.4 NOTES: 1. All bolts and gaskets identified by SCI logo. 2. 100% Magnetic particle inspection of each bolt. Each bolt has a minimum tensile strength of 110,000 psi. 3. Gaskets are pre-lubricated. 4. Gasket Grade E EPDM(green stripe): • Temperature range:-30T(-34°C)to+230°F(+110°C). 5. Gasket Grade T Nitrite (orange stripe): • Temperature range: -20°F(-29°C) to+180°F(+82°C). 6. Matches class 125/150 flange dimensions. 7. See Installation Instructions on Page 17 8. SMITH-COOPER Warranty(see page 19) only applies to assemblies made up using gaskets, housings, and bolts with the<>logo. c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com ' 6 • 0 0500 r4, < ' Series Short Radius Grooved Fittings - COUS APPROVED __ 1{ t- 1 0u. a -1"NPT C fi,x s x ," A , ., DRAIN I %;.lam I Ml= A I I_p_I I e l 1"DRAIN DRAIN 90°Elbow Tee Drain Cap Drain Elbow Fig. 65ES & 66ES- 90°Elbow, Short Radius Fig. 65TS & 66TS- Tee, Short Radius Part Number Nominal Actual Part Number Nominal Actual Pipe Size Pipe OD A Weight Pipe Size Pipe OD A Weight Painted Galv IN/mm IN/mm IN/mm LB/kg Painted Galv IN/mm IN/mm IN/mm LB/kg 65ES3020 66E63020 2 2.375 2.75 1 7 65183020 66153020 2 2.375 2 75 2,4 50 60.3 69.9 0.8 50 60.3 69.9 1.1 65E63024 66E63024 2-1/2 2 875 3.00 3.1 65183024 66158024 2-1/2 2 875 3 00 3.6 65 73.0 76.2 1.4 65 73.0 76.2 1.6 65E63030 66E63080 3 3 500 3,38 4.0 65153030 66183030 3 3 500 3 38 5 3 80 88.9 85.9 1.8 80 88.9 85.9 2.4 65E63040 66E63040 4 4 500 4.00 6.5 65153040 66133040 4 4 500 4 00 8 7 100 114.3 101.6 2.9 100 114.3 101.6 3.9 65ES3050 86ES8050 5 5.563 4.88 12 6 65133050 66133050 5 5 563 4.88 15.7 125 141.3 124.0 5.7 125 141.3 124.0 7.1 - 65E63060 68ES3060 6 6.625 5 50 18 3 65153060 66133060 6 6 625 5 50 22 7 150 168.3 139.7 8.2 150 168.3 139.7 10.2 65E63080 66E63080 8 8.625 6 81 25 5 65113080 66188080 8 8.625 6 94 38 7 200 219.1 173.0 11.5 200 2191 176.3 17.4 500 Series Grooved Fittings w/ Drains . Fig. 65DC& 66DC-Drain Cap Fig. 65DE& 66DE-Drain Elbow Part Number Nominal Actual Part Number Nominal Actual Pipe Size Pipe OD A Weight Pipe Size Pipe OD A B C Weight Painted Galv IN/mm IN/mm IN/mm LB/kg Painted Galv IN/mm IN/mm IN/mm_IN/mm IN/mm LB/kg 65063020 66068020 2 2 375 0.88 0.6 650E3020 660E3020 2 2 375 3 25 2.76 1.30 21 50 60.3 22.4 0.3 50 60.3 82.6 70.1 33.0 0.9 65068024 66068024 2-1/2 2 875 0 88 1.0 650E3024 660E3024 2-1/2 2 875 3 75 2 70 1 68 5 2 65 73 22.4 0.5 65 73.0 95.3 68.6 42.7 2.3 65068080 66068080 3 3 500 0 88 1.2 650E3030 660E3030 3 3 500 4.25 2.70 210 5 5 88.9 88.9 22.4 0.5 80 88.9 108.0 68.6 53.3 2.5 65063040 66068040 4 4.500 1 00 2 5 650E3040 688E3040 4 4 500 5.00 2.75 2 60 8 8 100 114.3 25.4 11 100 114.3 1270 69.9 66.0 4.0 65068050 66068050 5 5 563 1 00 4 6 650E3060 660E3060 6 6 625 6.50 s 2 75 3 65 18 7 125 141.3 25.4 2.1 150 168.3 165.1 69 9 92.7 8.4 • 65063060 66068060 6 6 625 1 00 6 1 650E3080 660E3080 8 8.625 7.75 12 75 4.57 28 6 150 168.3 25.4 2.7 200 219.1 196.9 69.9 116.1 12.9 65063080 66068080 8 8 625 1 20 13 1 200 219.1 30.5 5.9 c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 7 C. _ ; �. 500 Series Mechanical Tee-, Threaded � -• - , .Y I APPROVED • . i 1 B A .." • .. .14 .' -'''i ----1111114(S { ‘�,, T11. , M VJ c ___]________ iIr If_ . c \ O /may,,,,.............j 41. Fig. 65MT& 66MT-Mechanical Tee, Threaded Part Number Size Hole Diameter Max Working Dimensions Equivalent Run x Branch +1/8, -01+3.2, -0 Pressure A B C Length in Weight Painted Galv IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm Feet* LB/kg 65MT8020004 66MT3020004 2 x 1/2 1-1/2 500 2.50 4.96 2 80 3 1 - 50 x 15 38 ' 34 5 64.0 126.0 71.1 1.4 65MT8020006 66MT8020006 2 x 3/4 1-1/2 500 2 50 4 96 2.80 3 1 50 x 20 38 34.5 64.0 126.0 71.1 1.4 65MT3020010 66M13020010 2 x 1 1-1/2 500 2 50 4 96 2.80 2 3.0 50 x 25 38 34.5 64.0 126.0 71.1 1.4 2 x 1-1/4 1-3/4 500 2 80 4 96 2.80 3 5 65MT3020012 66M13020012 50 x 32 45 34.5 70.1 126.0 71.1 4 1.6 2 x 1-1/2 1-3/4 500 2.80 4.96 2 87 3 6 65M18020014 66M18020014 50 x 40 45 34.5 70.1 126.0 72.9 9 1.6 65MT3024004 66MT8024004 2-1/2x1/2 1-1/2 500 2 80 5 20 2 80 3.0 65 x 15 38 34.5 70.1 132.1 71.1 1.4- 65M18024006 66MT8024006 2-1/2x3/4 1-1/2 500 2 80 5.20 2 80 3.0 - 65 x 20 38 34.5 70.1 132.1 71.1 1.4 2-1/2 x 1 1-1/2 500 2.80 5 20 2.80 3.0 M13024010 65MT8024010 T3024010 65 x 25 38 34.5 70.1 132.1 71.1 2 1.4 2-1/2x1-1/4 1-3/4 500 3.00 5.20 3.03 3 5 65MT8024012 66M13024012 65 x 32 45 34.5 75.9 132.1 77.0 4 1.6 65M18024014 66MT3024014 2-1/2 x 1-1/2 2 500 3 00 5 20 3.27 3 6 65 x 40 51 34.5 75.9 132.1 83.1 9 1.6 65M13030010 66MT3030010 3 x 1 1-1/2 500 3.10 5.91 2 80 3 3 80 x 25 38 34.5 78.0 150.1 71.1 2 1.5 65M13080012 665113030012 3 x 1-1/4 1-3/4 500 3.27 5.91 3 03 4 3.8 80 x 32 45 34.5 83.1 150.1 77.0 1.7 65M13030014 66M13030014 3 x 1-1/2 2 500 3 50 5 91 3.27 3 4 1 80 x 40 51 34 5 88.9 150.1 83.1 1.8 65MT3030020 66=030020 3 x 2 2-1/2 500 3.50 5.91 3 78 5 4.9 80 x 50 64 34.5 88.9 150.1 '96.0 2.2 65MT8040010 66M18040010 4 x 1 1-1/2 500 3 54 7.09 2 80 2 3 6 100 x 25 . 38 34.5 89.9 180.1 71.'1 1.6 4 x 1-1/4 1-3/4 500 3 78 7 09 3.03 4.0 65M18040012 66MT8040012 100 x 32 45 34.5 96.0 180.1 77.0 4 1.8 65M13040014 665113040014 4 x 1-1/2 2 500 4 02 7.09 3.27 4.2 100 x 40 51 34.5 102.1 180.1 83.1 3 1.9 • NOTES: 1. All bolts and gaskets identified by SCI logo. 5. Gasket Grade T Nitrile(orange stripe): 2. 100% Magnetic particle inspection of each bolt. Each • Temperature range: -20°F(-29°C) to+180°F(+82°C). - bolt has a minimum tensile strength of 110,000 psi. 6. See Installation Instructions on Page 17 3. Gaskets are pre-lubricated. 7. SMITH-COOPER Warranty(see page 19) only applies to assemblies 4. Gasket Grade E EPDM(green stripe): made up using gaskets, housings, and bolts with the<>logo. • Temperature range:-30°F(-34°C)to+230°F(+110°C). c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wx%w.smithcooper.com ®i 1 8 £, I '0 . t t: '500 Series;Mechanical Tee, Grooved P MP c'0 us APPROVED 4t:i/ B ie.'1111 59 1 .V reir, rinli •� c .;s .. .. k�alP" 'U. Fig. 65MG & 66MG-Mechanical Tee, Grooved Part Number Size Hole Diameter Max Working Dimensions Equivalent Run x Branch +1/8, -0/+3.2, -0 Pressure A B C Length in Weight Painted Galv IN/mm IN/mm PSI/bar IN/mm IN/mm _ IN/mm _ Feet* LB/kg 3 x 1-1/4 1-3/4 500 3 50 5 90 3 00 3 7 65MG3030012 66MG8030012 4 80 x 32 45 34.5 89.9 150.1 77.0 1.7 3 x 1-1/2 2 500 3 50 5.90 I 3.30 3 8 65MG8080014 66MC3080014 80 x 40 51 34.5 89.9 150.1 83.1 3 1 7 65MG3030020 66MG3030020 3 x 2 2-1/2 500 3 50 5 90 3 80 5 4 6 80 x 50 64 34 5 89.9 150 1 96 0 2.1 65MG8040012 66MG3040012 4 x 1-1/4 1-3/4 500 4 00 7 10 3 00 4 3 6 100 x 32 45 34.5 102.1 180.1 77.0 • 1.6 65MG3040014 66MG3040014 4 x 1-1/2 2 500 4 00 7 10 3 30 3 3 9 100 x 40 51 34.5 102.1 180.1 83.1 1.8 . 65MG3040020 66MG3040020 4 x 2 2-1/2 500 4 00 7.10 3 90 5 4 6 100 x 50 64 34.5 102.1 180.1 100.1 21 65MG3040024 66MG3040024 4 x 2-1/2 2-3/4 500 4 00 7 20 4 20 11 5 0 100 x 65 70 34.5 102.1 183.9 106.9 2.3 - 65MG3040030 6611463040030 4 x 3 3-1/2 500 4 10 7.20 4 80 13 6 4 100 x 80 89 34 5 104.9 183.9 120.9 2 9 85M68050014 66M03050014 5 x 1-1/2 2 500 4 80 8.00 3 30 3 7 6 125 x 40 51 34.5 120.9 202.9 83 1 3.4 65MG3050020 66MG3050020 5 x 2 2-1/2 500 4.80 8.70 3 90 5 8 0 125 x 50 64 34.5 120.9 220.0 100.1 3.6 65MG8050024 663%3050024 5 x 2-1/2 2 3/4 500 4 80 8 70 4 20 11 8 0 125 x 65 70 34.5 120.9 220.0 106 9 3.6 65MG3050030 66MG3050030 5 x 3 3-1/2 500 4 80 8 70 4 90 13 8 8 125 x 80 89 34.5 120.9 220.0 125.0 4.0 65M63060012 66MG3060012 6 x 1-1/4 1-3/4 500 5 10 9.10 3 00 4 4 8 150 x 32 45 34.5 130.0 231.9 77 0 2.2 65MG3060014 663163060014 6 x 1-1/2 2 500 5 10 9.10 3 30 3 5 1 150 x 40 51 34.5 130 0 231.9 83 1 2 3 65MG3080020 66M63060020 6 x 2 2-1/2 500 5 10 9 80 3 90 5 5 6 150 x 50 64 34.5 130.0 247.9 100.1 2.5 65MG3060024 66MG3060024 6 x 2-1/2 2-3/4 500 5 10 9.80 4 20 11 7 6 150 x 65 70 34.5 130.0 247.9 106.9 3.4 65MG3060030 666163060030 6 x 3 3-1/2 500 5 10 9 80 4 90 13 8 4 150 x 80 89 34.5 130.0 247 9 125:0 3.8 65MG3060040 66MG3080040 6 x 4 4-1/2 500 5.40 9 80 5 90 15 10 1 150 x 100 114 34 5 136.9 247.9 150 1 4.5 65MG3080020 66MG3080020 8 x 2 2-1/2 500 6 26 11 81 3.94 5 11 6 200 x 50 64 34.5 159.0 300.0 100 1 5.2 65M68080024 66MG3080024 8 x 2-1/2 2-3/4 500 6 26 11 81 4.21 1 11 11 6 200 x 65 70 34.5 159.0 300.0 106.9 5.2 65MG3080030 66MG3080030 8 x 3 3-1/2 500 6 26 11 81 4.92 13 11 6 200 x 80 89 34.5 159.0 300.0 125.0 5.2 65MG3080040 66MG3080040 8 x 4 4-1/2 500 6 38 11 81 , 5 91 1 15 12 5 200 x 100 114 34.5 162.1 300.0 150.1 5.6 NOTES: 1. All bolts and gaskets identified by SCI logo. 5. Gasket Grade T Nitrite(orange stripe): 2. 100%Magnetic particle inspection of each bolt. Each •Temperature range:-20°F(-29°C)to+180°F(+82°C). bolt has a minimum tensile strength of 110,000 psi. 6. See Installation Instructions on Page 20. 3. Gaskets are pre-lubricated. 7. SMITH-COOPER Warranty(see page 19)only applies to assemblies 4. Gasket Grade E EPOM(green stripe): made up using gaskets, housings,and bolts with the.O.logo. •Temperature range:-30°F(-34°C)to+230°F(+110°C). 8. Equivalent Length in Feet of Schedule 40 Outlet Pipe with a Hazen-Williams Coefficient of 120 per UL 213. c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 13 'c, ; ije 500 Series Strap Tee, Threaded 1 i,, ;r , �� .� B C0US • 4 �l I_- .{ / APPROVED ■ 9 ■ 1 /4,..„..t: :.4,:; ,.. ‘,, z A UPI _ VIM + nvqy - it - - \,.....L. 1 / .'' ill ta' Fig. 65MU& 66MU-Strap Tee, Threaded Part Number Size Hole Diameter Max Working Dimensions Equivalent Run x Branch +1/8, -0/+3.2, -0 Pressure A B C Lenght in Weight Painted Galv IN/mm IN/mm PSI/bar IN/mm IN/mm IN/mm Feet* LB/kg 65MU8012004 66M08012004 1-1/4 x 1/2 i 1-1/4 300 1.65 3 54 2.28 3 1 - 32 x 15 32 20.7 41.9 89.9 57.9 1.4 65MU8012006 66M08012006 1-1/4 x 3/4 1-1/4 300 1.85 3.54 2 28 3 1 - 32 x 20 32 20.7 47.0 89.9 _ 57.9 1.4 1-1/4 x 1 1-1/4 300 2.13 3.54 2.28 3.0 65MU8012010 66MU3012010 32 x 25 32 20.7 54.1 89.9 57.9 5 1.4 65MU3014004 66M08014004 1-1/2 1-1/2x1/2 1-1/4 300 1.77 3.54 2 28 3.1 - 40 x 15 32 20.7 45.0 89.9 57.9 1.4 65M08014006 66M08014006 1-1/2x3/4 1-1/4 300 1.97 3.54 2.28 3.1 - 40 x 20 32 20.7 50.0 89.9 57.9 1.4 1-1/2 x 1 1-1/4 300 2.24 3 54 2 28 3 0 65M08014010 66M08014010 40 x 25 32 20.7 56.9 89.9 57.9 5 1.4 65M08020004 66MU3020004 2 x 1/2 1-1/4 300 2.01 3.74 2.28 3.1 - 50 x 15 32 20.7 51.1 95.0 57.9 1.4 65M08020006 66M08020006 2 x 3/4 1-1/4 300 2 20 3.74 2 28 3.1 - 50 x 20 32 20.7 55.9 95.0 57.9 1.4 65MU8020010 66M08020010 2 x 1 1-1/4 300 2 48 3.74 2.28 5 3 0 50 x 25 32 20.7 63.0 95.0 57.9 1.4 65MU3024004 66M03024004 2-1/2 x 1/2 1-1/4 300 2.26 4 29 2 28 3 0 - 65 x 15 32 20.7 57.4 109.0 57.9 1.4 65MU8024006 66M08024006 2-1/2 x 3/4 1-1/4 300 2 50 4 29 2 30 3 0 - 65 x 20 32 20.7 62.5 109.0 57.9 1.4 65MU3024010 665108024010 2-1/2 x 1 1-1/4 300 2.70 4.29 2 30 5 3 0 65 x 25 32 20.7 69.6 109.0 57.9 1.4 NOTES: 1. All bolts and gaskets identified by SCI logo. 2. 100% Magnetic particle inspection of each bolt. Each bolt has a minimum tensile strength of 110,000 psi. 3. Gaskets are pre-lubricated. 4. Gasket Grade E EPDM(green stripe): • Temperature range:-30°F(-34°C)to+230°F(+110°C). 5. Gasket Grade T Nitrile(orange stripe): . •Temperature range:-20°F(-29°C)to+180°F(+82°C). 6. See Installation Instructions on Page 17. 7. SMITH-COOPER Warranty(see page 19)only applies to assemblies - made up using gaskets, housings, and bolts with the<>logo. 8. Equivalent Length in Feet of Schedule 40 Outlet Pipe with a Hazen-Williams Coefficient of 120 per UL 213. 9. 1"outlets not listed by UL for direct connection to 1"sprinkler heads. c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smiEhcooper.com 14 . , "ctillv,,, �� � i . . `< � UL Listed FM A pp roved-Sp rinkler Pi p e ad' mation ' ' SCI COOPLOKrM Grooved Couplings are UL Listed and FM Approved c 0 us for use on the following types of sprinkler pipe:* APPROVED PIPE NAME MANUFACTURER • Dyna-Thread, Centr®l-T ®read , XL®, XL-II®, Dyna-Flow®, Allied Tube and Conduit Corp. Super 40®, Super-Flo®,TL®, Central 7®, BLT® Eddy lite®, Eddy Flow®, Eddy Thread 40® Bull Moose Tube Co. Gal-7® IDOD Systems Co. EZ-Flow® Northwest Pipe & Casing Co. WLS®, Mega-Flow®, Mega-Thread®, MLT®, GL® Wheatland Tube Company Steady Flow®, Steady Thread® Welded Tube Corp. • Fire-Flo®, EZ-Thread® Youngstown Tube Co. Tex Flow® Tex Tube International SPSF® Yieh Phui Enterprise Co. Ltd. ' *NOTE:Includes any manufacturer of Schedule 10 or Schedule 40 steel pipe. Check www.SmithCooper.com for updated list of UL Listed/FM Approved sprinkler pipe manufacturers. WARRANTY AND LIMITATIONS OF LIABILITY SMITH-COOPER INTERNATIONAL(SCI)warrants to its initial purchaser only,that its products which are delivered to this initial purchaser will be of the kind described in the order or price list and will be free of defects in workmanship or material for a period of five years from the date of delivery to our initial purchaser Should any failure to conform to this warranty appear within five years after the date of the initial delivery to our initial purchaser,SCI will,upon written notification thereof and substantiation that the goods have been stored,installed,maintained and operated in accordance with recognized engineering and piping practices and industry standards,correct such defects by suitable repair or replacement(which alternative shall be at the discretion of SCI)of product at SCI's own expense upon return of the defective part to SCI. In the event that SCI elects to replace the defective product,SCI shall pay up to S50 per defective product for total cost of replacement. In the event of multiple claims, such payment shall be no greater than S1,000 for each installation project. This warranty applies only during normal use that meets the above referenced conditions of installation and operation and is absolutely void if the product has been damaged after purchase or if it has been misused,repaired,altered or modified in any manner whatsoever. SCI shall not warranty any of its products if any portion of the product including without limitation,any component,gasket,housing or bolt has been modified,altered,remanufactured or replaced in any manner by any customer, user of the product or third party Correction of non-conformities,in the manner and for the period of time provided above,shall constitute fulfillment of all liabilities of SCI to our initial purchaser,with respect to the goods,whether based on contract,negligence,strict tort,or otherwise. It is the intention of SCI that no warranty of any kind,whether expressed or implied shall pass through our initial purchaser to any other person or corporation. No returns will be allowed unless prior written permission of SCI is first obtained. Buyers shall be responsible for all costs of transportation as well as a restocking charge. This warranty is exclusively for the benefit of the initial purchaser of this product from SCI and,except to the extent prohibited by applicable law,the foregoing warranty is in lieu of all other warranties,express or implied,including but not limited to warranties of fitness or merchantability LIMITATIONS OF LIABILITY:SCI shall not under any circumstances be liable for special or consequential damages such as,but not limited to damage to loss of other property or equipment,loss of profits or revenue,cost of capital,cost of purchased or replacement goods,claims of customers of our initial purchaser,any labor cost for repair or replacement of the product or damage caused by the product. The remedies of our initial purchaser,and all others,set forth herein are exclusive,and the liability of SCI with respect to same shall not,except as expressly provided - herein,exceed the price of the SCI products on which such liability is based. DISCLAIMER.Smith-Cooper International cannot be held responsible for omissions or errors in this catalog. Please refer to www.smithcooper.com for current information c Ous SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 19 • Pipe Hangers • Fig. 2 - Adjustable Band Hanger (B-Line B3170) c UL us Fig. 2F - Adjustable Band Hanger Felt Lined for Copper Tubing (B-Line B3170F) usrmo • Size Range: ®TOLCO- Fig. 2 - 21/2"(65mm)thru 6"(150mm) pipe i" Fig. 2F - 21/2" (65mm)thru 6" (150mm) pipe " • Material: Pre-Galvanized Steel i c B ^ Function: Recommended for the suspension of non- '• insulated pipe or insulated pipe with B3151 shield. / t r. Fig. 2NFPA accomodates the reduced rod schedule of (' o the National Fire Pretection Association Pamphlet 13. \,,,,,,\,,v4O_;,/- Approvals: Factory Mutual Engineering Approved. _J Underwriters Laboratories Listed. Conforms to Federal - Specification WW-H-171 E&A-A-1192A Type 10 and Fig.2 Manufacturers Standardization Society ANSI/MSS SP-69 &SP-58,Type 10. Standard Finish: Pre-Galvanized ( Note: Available in Stainless Steel material. • Order By Part number and finish. 1/7"- ' c 3 'v['� .. B I f '., / '1 U . Fig.2 Fig.2F Nominal Pipe S ze F ,i Rod-Sized; . B'• a (1. C r ,;; I. Dt ' ii: Max:Rec Load i Approx Wt./100, , $ _Part Nod in ,' (mm i. A. 1L m 'Only`Ji` m_,_(mm) ,11 L ui (mm) `L lbs.. (kN)T �_Ibs l_� (kg)J• 2-2'12 21/2" (65) 1/2"-13* 53/4" (146.0) 41/4" (107 9) 15/8" (41 3) 600 (2.67) 41 (18.6) m 2-3 3" (75) 1/2"-13* 6" (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4) `1 2-31/2 31/2" (90) 1/2"-13" 73/8" (187.3) 51/4" (133 3) 21/8" (54.0) 600 (2 67) 52 (23.6) 2-4 4" (100) 5/8"-11 * 73/8" (187.3) 5" (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6) 2-5 5' (125) 5/8"-11 " 9' (228.6) 61/8" (1556) 21/4" (57.1) 1250 (5.56) 97 (44.0) 2-6 6" (150) 3/4"-10" 93/8" (238.1) 61/2" (165.1) 17/8" (47.6) 1250 (5.56) 139 (63.0) Fig.2F Bernina-11j Pipe Size •I1 Rod Size *lI B- I _ Of T1r Max. Load i1 Approx Wt/100 Part No ll in (mm) ;, A �( .m (mm) �t in (mil)., •in: + (mm). It t Ibs (kN) i Ibs (kg)_J 2F-21/2 21/2 (65) 1/2"-13' 53/4" (146.0) 41/4" (107.9) 15/8" (41.3) 600 (2.67) 41 (18.6) 2F-3 3' (75) 1/2"-13* 6' (152.4) 41/8" (104.8) 11/4" (31.7) 600 (2.67) 45 (20.4) 2F-31/2 31/2' (90) 1/2"-13" 73/8" (187.3) 51/4 (133.3) 21/8" (54.0) 600 (2.67) 52 (23.6) 2F-4 4" (100) 5/8"-11 * 73/8" (187.3) 5' (127.0) 15/8" (41.3) 1000 (4.45) 59 (27.6) 2F-5 5' (125) 5/8"-11 " 9 (228.6) 61/8 (155 6) 21/4" (57.1) 1250 (5.56) 97 (44.0) 2F-6 6' (150) 3/4"-10" 93/8" (238.1) 61/2' (165.1) 17/8' (47.6) 1250 (5.56) 139 (63.0) *3/8 nut is used when requested. " 1/2 nut is used when requested. B-Line All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. by E...T.N 59 Pipe Hangers&Supports Threaded Accessories • Fig. B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) ®TOLCO Fig. B3205L - Threaded Rod (right& left hand threads) . Size Range: 3/8"-16 thru 3"-4 rod TL Material: Steel Specify Length Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown.Also TL \� ��l�l111111111 available with left and right hand threads-specify Fig. B3205L when ordering. Maximum Temperature: 750°F(399°C) ��l�lll�l� A p ( Thread Size Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2 (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2' (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2' (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 133205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (1560) For larger sizes consult full line pipe hanger catalog. s a' Fig. ATR - All Threaded Rod (TOLCO Fig.99&Fig. 100) ■ C. CD n Size Range: 3/8"-16 thru 11/2"-6 rod in 10' (3.05m)lengths �� H 1111 Material: Steel ° �� 11. in Maximum Temperature: 750 F(399°C) � ''111111 o. 1:e 111 H Finish: Plain . Contact Cooper B-Line for alternative finishes and materials. x 111 1 Order By: Figure number, rod size, length and finish , Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. lb Part No. Threads Recommended Load Approx.Wt./100 Ft. &Size Per Inch Lbs. (kN) Lbs. (kg) ATRIA"x'L' 20 240 (1.07) 12 (5.44) '-'< ATR 3/8"x'L' 16 730 (3.24) 29 (13.15) AIR 1/2"x'L' 13 1350 (6.00) 53 (24.04) ATR 5/8"x'L' 11 2160 (9.60) 89 (40.37) ATR 3/4"x'L' 10 3230 MEM 123 (55.79) ATR 7/8"x'L' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line • Beam Clamps • Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (ID TOLCO' Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) c 0 US . Size Range: USTED Fig. 65 - 1/2"-13 rod sizes, and 5/8"-11 rod sizes Fig. 65XT - 3/8"-16 rod size(see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). B D Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip .42 allows hanging from top flange where clearance is limited.) May be installed with set ilIP E screw in up or down position. Offset design permits unlimited rod adjustment by 4/��/ ,(r 0 allowing the rod to be threaded completely through the clamp. Open design permits /, inspection of thread engagement. F �C Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada (cUL). A Exce eds requirements of the National Fire Protection Association (NFPA), pamphlet 13, %we 3/8"-16 rod will support 1/2" (15mm)thru 4"(toomm) pipe `/ 1/2"-13 rod will support thru 8"(200mm) pipe Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Set Screw add Locknutlnclued Order By: Figure number and finish Fig.65 Patent#4,570,885 L.. mt , R. to 21 L- itCM Part Rod Size B C D E • ; No. A in. (mm) in. (mm) in. (mm) in. (mm) 65-1/2 1/2"-13 11/2" (38.1) 3/4" (19.0) 1" (25.4) 9/16" (14.3) .� f 65-5/8 5/8"-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) 9/16" (14.3) d Part F Approx.Wt./100 '_ No. in. (mm) Lbs. (kg) I i ., 65-5/2 11/4" (31.7) 55 (24.9) iiti 65-5/8 11/4" (31.7) 55 (24.9) •Maximum loads for clamp with set screw in up or down position. Fig. 65XT-3/8 - Beam Clamp - .(5.4 ) c ® us Feature: Extruded holes allows for more thread 1.ISTEp engagement of threaded rod and set screw. 18ii8" Weight: Approx.Wt./100 - 28.0 Lbs. (12.7kg) i',70„ (39'7) Finish: Plain or Electro-Galvanized 3/," 'ei ` , / f Order By: Figure number and finish (1901 �� - Approvals: Underwriters Laboratories Listed %�f ," . (cULus)and FM Approved (FM)for up to 4" *00 ----pi,- +,i • (100mm) pipe. + Set Screw and �e Locknut Included 13/8" (22.2) - ..--r Designed to meet or exceed requirements of (34,9) . FM DS 2-0. ,._ _ io All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Beam Clamps Fig. 69 - Beam Clamp Retaining Strap (Cooper B-Line B3367) ®TOLCO' Size Range: 3/8"-16 thru 3/4"-10 rod C OUS 4" (101.6mm)thru 16"(406.4mm) lengths LISTED Note: longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas.Satisfies requirements of NFPA 13. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly.Therefore a locking mechanism of some kind, such as a hex for the Fig. 69 will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). Approved for use with any listed beam clamp. Finish: Pre-Galvanized Order By: Figure number, length (L), and finish. Note: Minimum return on strap is 1"(25.4mm) For Use With: Any Cooper B-Line or TOLCO beam clamp. co U; E co Hole Dia.D Length mos Part No. in. (mm) 69-3/8-L 7/16" (30.1) Specify ii 69-1/2-L 9/16" (30.1) Specify E a� 69-5/8-L 11/16" (50.8) Specify 69-3/4-L 13/16" (63.5) Specify 1o1 11 All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Seismic Bracing • Fig. 4L - Longitudinal "In-Line" Sway Brace Attachment ®TOLCO' Size Range: 2" (50mm)through 8" (200mm) IPS. (20 Material: Steel C US o Function: For bracing pipe against sway and seismic disturbance. �S�O ro. Set Bolt&Hardware Included 6 Approvals: Underwriters Laboratories Listed in the USA(UL) and se ri Canada (cUL) 2" (50mm)through 8" (200mm) pipe. � For FM Approval information refer to page 47. AIL mr ' Installation Instructions: Fig. 4L is the "braced pipe" attachment /41/1 .-1.."›„W# tO•t.' component of a longitudinal sway brace assembly. It is intended to be Ljr. combined with the "bracing pipe" and Cooper B-Line,TOLCO structural A attachment component to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts.Then engage "bracing pipe" into law opening and tighten set bolt 0 until head snaps off. Jaw attachment can pivot for adjustment to proper b ilk , )- race angle. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. C J / ..... ...=.' -,--, fir,- .1 / \ E: 7 0„.:,,. ... `!i �r f+ 11 4-Way Riser Brace i'— ... (plan view) Longitudinal Brace Pipe Max.Rec.Load Approx. Part Size A C D Bolt Size (cULuc) Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 41-2 ® (50) 53/8" (136.5) 21/16 (52 4) 21/16" (52.4) 1/2"-13 2015 (8 96) 247 (112.0) 4L-21/2 ® (65) 67/16" (163.5) 21/2" (63.5) 23/4" (69.8) 1/2"-13 2015 (8.96) 253 (114.7) 4L-3 ® (80) 7" (177.8) 23/4" (69.8) 31/16 (77 8) 1/2"-13 2015 (8 96) 268 (121 5) 41-4 n (100) 81/2" (215.9) 33/8" (85.7) 311/16" (93.7) l/2"-13 2015 (8.96) 348 (157.8) 41-5 ® (125) 93/4" (247.6) 37/8" (984) 43/s" (1111) 1/2"-13 2015 (8.96) 380 (172.3) 41-6 6" (150) 111/2" (292.1) 5" (127.0) 51/8" (130.2) 1/2"-13 2015 (8.96) 640 (290.3) 41-8 8' (200) 131/4" (336.5) 55/8" (142.8) 55/s" (142 9) 1/2"-13 2015 (8.96) 728 (330 2) The loads listed are axial loads on the brace.The horizontal load capacity, H, of the brace is: H = F x sin ?, where?the installation angle measured from the vertical. Cooper B-Line, Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified COOPER B-Line Seismic Bracing • Fig.4L - Longitudinal "In-Line"Sway Brace Attachment ®TOLCO• Size Range: 21/2" (65mm)through 8" (200mm)IPS. • Material: Steel APPROVED Function: For bracing pipe against sway and seismic disturbance. Set Bolt&Hardware Included c Approvals: Approved by Factory Mutual Engineering(FM),21/2" (65mm) ctr through 8" (200mm)pipe. ��A I m For UL Listed information refer to page 46. °7 Installation Instructions: Fig.4L is the "braced pipe" attachment rni component of a longitudinal sway brace assembly. It is intended to be A combined with the "bracing pipe"and Cooper B-Line/TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or FM guidelines should be followed. tLI To Install: Place the Fig.4L over the pipe to be braced and tighten 0 bolts.Then engage"bracing pipe" into jaw opening and tighten set bolt until head snaps off.Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. c Order By: Figure number, pipe size and finish. Designed to meet or exceed requirements of FM DS 2-8. let t* I�I Iolp Q 4-Way Riser Brace (plan view) Longitudinal Brace Pipe *Max.Design Load(FM) Approx. Part Size A C D Bolt Size 30 0-44° 450-59° 60°-74° 750-90° Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs. (kg) 4L-2112® (65) 67/16" (163.5) 21/2" (63.5) 23/4" (69.8) 1/2"-13 1030(4.58) 1180(5.24) 1420(6.31) 1590(7.07) 253 (114.7) 41-3 ® (80) 7" (177.8) 23/4" (69.8) 31/16" (77.8) 1/2"-13 1030(4.58) 1180(5.24) 1420(6.31) 1590(7.07) 268 (121.5) 41-4 4" (100) 81/2" (215.9) 33/8" (85.7) 311/16" (93.7) 1/2"-1 3 530(2.36) 730(3.25) 890(3.96) 990(4.40) 348 (157.8) 41-5 ® (125) 93/4" (247.6) 37/8" (98.4) 43/8" (111.1) 1/2"-13 530(2.36) 730(3.25) 890(3.96) 990(4.40) 380 (172.3) 41-6 6" (150) 111/2" (292.1) 5" (127 0) 51/8" (130 2) 1/2"-1 3 530(2.36) 730(3.25) 890(3.96) 990(4.40) 640 (290.3) 41-8 (200) 131/4" (336.5) 55/s" (142.8) 53/8" (142.9) 1/2"-13 490(2.18) 680(3.02) 830(3.69) 930(4.13) 728 (330.2) FM Approved when used with 1", 11/4", 11/2"or 2"Sch.40 brace pipe. FM Approved design loads are based on ASD design method. Cooper B-Line, Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Seismic Bracing Fig. 1001 - Sway Brace Attachment ®TOLCO' Size Range: Pipe size to be braced: 21/2" (65mm)thru 8" (200mm) IPS. C ® US ' Pipe size used for bracing: 1" (25mm)and 11/4" (32mm)Schedule 40 IPS. cn. Material: Steel USTED aFunction: For bracing pipe against sway and seismic disturbance. 5; The pipe attachment component of a sway brace system: Crt Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13,forming a complete 2,;' sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced ilet and tighten two hex head cone point set bolts until heads bottom cluded out.A minimum of 1" (25mm)pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). UL Listed Design Load For FM Approval information refer to page 65. Sch.7 - 1600 lbs.(7.11 kN) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Sch.10&40 w/1"(25mm)Brace Pipe Order By: Order by figure number, pipe size to be braced,followed by pipe 2015 lbs.(8.96kN) size used for bracing (1" (25mm)or 11/4" (32mm)) , and finish. Sch.10&40 w/11/4"(32mm)Brace Pipe • Important Note: Fig. 1001 is precision manufactured to perform its 2765 lbs.(12.30kN) function as a critical component of a complete bracing assembly.To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other Cooper B-Line/TOLCO bracing products. Pipe Part Number&Approx.Wt./100 Design Size 1"(24mm)Brace Pipe 11/4"(32mm)Brace Pipe Load in. (mm) Lbs. (kg) Lbs. (kg) ** �. ® (65) 1001-21/2 X 1 138.6 (62.8) 1001-21/2 X 11/4 160.4 (72.7) UL 1131 (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) UL (100) 1001-4 X 1 160.9 (73.0) 1001-4 X 11/4 182.4 (82.7) UL 6" (150) 1001-6 X 1 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) UL 8" (200) 1001-8 X 1 217.4 (98.6) 1001-8 X 11/4 238.8 (108.3) UL "See load ratings in UL Listed Design Load chart. ' The loads listed are axial loads on the brace.The horizontal load capacity, H,of the brace is H=F x sin?,where?is the installation angle measured from the vertical. . .4 •All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - 3/8" to 3/4" ®TOLCO- Size Range: One size fits bracing pipe 1" (25mm)thru 2" (50mm), Cooper C ® US B-Line 12 gauge(2.6mm)channel, and all structural steel up to 1/4" (31.7mm)thick. LISTED m Material: Steel 3. Function: Multi-functional attachment to structure or braced pipe fitting. cot Features: This product's design incorporates a concentric attachment %!_ s, opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on 980 \ concentric loading. Mounts to any surface angle. Break off bolt head assures ©1� verification of proper installation. o Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined A with the "bracing pipe" and Cooper B-Line/TOLCO "braced pipe" attachment, B Fig. 1000, 1001,2002, 4L, 4A or approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. Set Bolt To Install: Place the Fig. 980 onto the "bracing pipe".Tighten the set bolt until Included the head breaks off.Attachment can pivot for adjustment to proper brace angle. Mounting Hardware Is Not Included Approvals: —Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). For FM Approval information refer to page 61. Note: Fig. 980 Swivel Attachment and Fig. 1001, 1000,2002, 4A or approved ; t` attachment to pipe that make up a sway brace system of UL Listed 4 ,� attachments and bracing materials which satisfies the requirements of - Underwriters Laboratories and the National Fire Protection Association(NFPA) A Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish. Pat.#6,273,372, Pat.#6,517,030, Pat.#6,953,174, Pat.#6,708,930, Pat.#7,191,987, Pat.#7,441,730, Pat.#7,669,806 -- Fig.980 : 4A FIg.4L AO/ +#4, Lateral Brace Longitudinal Brace Part Mtg.Hdw. Mounting Hole Max.Design Approx. Number Size A B D Load(cULus) Wt./100 in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 980-3/8 Ez (9.5) 51/4" (133.3) 17/8" (47.6) 13/32" (10.3) 2765 (12.30) 133 (60.3) 980-1/2* ® (12 7) 51/4" (133.3) 17/8" (47.6) 17/32" (13.5) 2765 (12.30) 132 (59.7) 980-5/8 Ei (15.9) 51/4" (133.3) 17/8" (47.6) 11/16" (17.5) 2765 (12.30) 131 (59.4) 980-3/4 1121 (19.0) 51/4" (133.3) 17/8" (47.6) 13/16" (20.5) 2765 (12.30) 130 (58.9) •Standard size. Cooper B-Line, Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line • bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 60 0011 COOPER B-Line Win Metro Safety & Fire 14324 SE Stark Street; Portland, Oregon 97233 PHONE (503)231-2999 CCB#63651 UPS Distribution Center 14160 SW 72nd Avenue Tigard, Oregon P R()Fes, ‘AG INEF9 X02 cc A 12089PE(11(0;41 061" OREGON �4Y 20, 1g� �C� i4N C 0\-5 EXPIRES: 12/31/2016 FIRE PROTECTION SEISMIC CALCULATIONS Tol-Brace Seismic Calculations Metro Safety&Fire PI oject Address: UPS Distribution Center —._ _ 14324 SE Stark Street B -L.jfle • 14160 SW 72nd Avenue Portland,Oregon 97233 _._ --------- (503)231-2999 by FIT.N Tigard, Oregon CCB 63651 Job# 15-1106-MS Calculations based on 2013 NFPA Pamphlet#13 Brace Information Tolco Brace Components Maximum Spacing 21'0" (6.4 m) Tolco Component Fig. Number Adjusted Load Maximum Brace Length 7' 0" (2.13 m) Fig.1001 Clamp 1425 lbs(646 kg) Bracing Material 1" Sch.40 Fig.980 Universal Swivel 1425 lbs(646 kg) Angle from Vertical 45° Min. "Calculation Based on CONCENTRIC Loading 'Please Note:These calculations are for Tolco components only.Use of any other components voids these calculations and the listing of the assembly Least Rad.of Gyration 0.42" (11 mm) Assembly Detail UR Value 200 Max Horizontal Load 1310 Ibs`(594 kg) TOLCO FIG. 981 UNIVERSAL SWAY BRACE Force Factor(Cp) 0.5 ATTACHMENT STEEL PIPE �o • Fastener Information •�� Fastener Orientation NFPA Type B Maximum Load 2050 lbs(930 kg) �.�r// ♦�' Diameter 4�� 1/2n.(12 mm) TOLCO FIG. 1001 .♦ FAST CLAMP ' Length N/A �� Type Bolt Brace Identification on Plans Lai Orientation of Brace Lateral Braced Pipe:6"Sch.10 Steel Pipe Load Information Size and Type of Pipe Total Length Total Calculated Load 6"Sch.10 Steel Pipe(152.4 mm) 21ft(6.4 m) 242 lbs(110 kg) 2"Sch.40 Steel Pipe(50.8 mm) 18ft(5.5 m) 46 lbs(21 kg) 2"Sch.10 Steel Pipe(50.8 mm) 168ft(51.2 m) 354 lbs(161 kg) Percentage added for Fittings and Sprinklers 115% 96 lbs(43.55 kg) Total Adjusted Load of all pipe within Zone of Influence 739 lbs(335 kg) ITol-Brace Verizon Bt } Tol-Brace Seismic Calculations UPS Distribution Center Job#15-1106-MS B I..ine 14160 SW 72nd Avenue r Brace Identification Lal by E_ Brace Type(Per NFPA#13) NFPA Type B Braced Pipe 6" Sch.10 Steel Pipe Spacing of Brace 21' 0" (6.4 m) Orientation of Brace Lateral Bracing Material 1"Sch.40 Maximum Brace Length 7' 0" (2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 1/2 (12mm) Bolt Length of Fastener N/A Summary of Pipe within Zone of Influence 6"Sch.10 Steel Pipe(152.4 mm) 21ft(6 4 m) 2"Sch.40 Steel Pipe(50.8 mm) 18ft(5.5 m) 2"Sch 10 Steel Pipe(50.8 mm) 168ft(51.2 m) Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 739 lbs (335 kg) Material Capacity 1310 lbs(594 kg) Fastener Capacity 2050 lbs(930 kg) Fig. 1001 Clamp 1425 lbs(646 kg) Fig.980 Universal Swivel 1425 lbs(646 kg) Structural Member Top Chord of Truss of Joist Calculations prepared by M.Walter,SET *The description of the Structural Member is for informational purposes only. Tol-Brace software calculates the brace assembly only,not the structure it is attached to. Calculated with Tol-Brace 8 Visit us at www tolco com • Tol-Brace Seismic Calculations Metro Safety&Fire IProject Address: UPS Distribution Center 14324 SE Stark Street B-Line Portland,Oregon 97233 14160 SW 72nd Avenue (503)231-2999 by EffeRI Tigard, Oregon CCB 63651 Job#15-1106-MS Calculations based on 2013 NFPA Pamphlet#13 Brace Information Tolco Brace Components Maximum Spacing 63' 0" (19.2 m) Tolco Component Fig. Number Adjusted Load Maximum Brace Length 7' 0" (2.13 m) _ Fig.4L Clamp 1425 lbs(646 kg) Bracing Material 1" Sch.40 Fig.980 Universal Swivel 1425 lbs(646 kg) Angle from Vertical 45° Min. `Calculation Based on CONCENTRIC Loading `Please Note These calculations are for Tolco components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42" (11 mm) �T w Assembly Detail L/R Value 200 TOLCO FIG. 98 Max Horizontal Load 1310 lbs (594 kg) UNIVERSAL SWAY BRACE ATTACHMENT $ Force Factor(Cp) 0.5 STEEL PIPE j Fastener Information ice . Fastener Orientation NFPA Type B TOLCO FIG. 4L PIPE CLAMP FOR Maximum Load 2050 lbs(930 kg) SWAY BRACING if • Diameter 1/2n.(12 mm) Length N/A C Type Bolt Brace Identification on Plans Lol Orientation of Brace Longitudinal Braced Pipe:6"Sch.10 Steel Pipe Load Information Size and Type of Pipe Total Length Total Calculated Load 6"Sch.10 Steel Pipe(152.4 mm) 63ft(19 2 m) 725 lbs(329 kg) Percentage added for Fittings and Sprinklers 115% 109 lbs(49.44 kg) Total Adjusted Load of all pipe within Zone of Influence 834 lbs(378 kg) (Tol-Brace Verizon 8) • Tol-Brace Seismic Calculations UPS Distribution Center Job#15-1106-MS B I..ine 14160 SW 72nd Avenue Brace Identification Lol by Fa1•N Brace Type(Per NFPA#13) NFPA Type B Braced Pipe 6" Sch.10 Steel Pipe Spacing of Brace 63'0" (19.2 m) Orientation of Brace Longitudinal Bracing Material 1" Sch.40 Maximum Brace Length 7'0" (2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 1/2 (12mm) Bolt Length of Fastener N/A Summary of Pipe within Zone of Influence 6"Sch.10 Steel Pipe(152.4 mm) I 63ft(19.2 m) Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 834 lbs(378 kg) Material Capacity 1310 lbs(594 kg) Fastener Capacity 2050 lbs(930 kg) Fig.4L Clamp 1425 lbs(646 kg) Fig.980 Universal Swivel 1425 lbs(646 kg) Structural Member Top Chord of Joist or Truss Calculations prepared by M.Walter,SET 'The description of the Structural Member is for informational purposes only. Tol-Brace software calculates the brace assembly only,not the structure it is attached to. Calculated with Tol-Brace 8 Visit us at www tolco.com