Code Analysir)
BASED ON THE 2010 OREGON STRUCTURAL AND SPECIALTY CODE
OCCUPANCY AND CONSTRUCTION
ASSUMED OCCUPANCY: B/S2
NON—SEPARATED USE BETWEEN: N/A
CONSTRUCTION TYPE: V—B
FIRE—RESISTANCE RATING REQUIREMENTS
STRUCTURAL FRAME: 0 HRS.
EXTERIOR BEARING WALLS: 2 HRS.
EXTERIOR NON—BEARING WALLS: 0 HRS.
INTERIOR NON—BEARING WALLS: 0 HRS.
FLOOR CONSTRUCTION: 0 HRS,
0
EXITING:
B OCCUPANCY: COMMON PATH OF EGRESS TRAVEL DISTANCE DOES NOT EXCEED 75'-0" PER OSSC SECTION 1014.3
EXIT ACCESS TRAVEL DISTANCE DOES NOT EXCEED 200'-0" PER OSSC SECTION 1016.1
S2 OCCUPANCY: COMMON PATH OF EGRESS TRAVEL DISTANCE DOES NOT EXCEED 758-0" PER OSSC SECTION 1014.3
EXIT ACCESS TRAVEL DISTANCE DOES NOT EXCEED .300'-0" PER OSSC SECTION 1016.1
EMERGENCY LIGHTING: IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM
SHALL AUTOMATICALLY ILLUMINATE THE PORTION OF THE EXTERIOR EXIT DISCHARGE
IMMEDIATELY ADJACENT TO EXIT DISCHARGE DOORWAYS IN BUILDINGS REQUIRED
TO HAVE TWO OR MORE EXITS WITH THE EXIT ILLUMINATION SUPPLEMENTED WITH
AN EMERGENCYPOWER SUPPLY CAPABLE OF PROVIDING POWER FOR A DURATION OF
NOT LESS THAN 90 MINUTES PER OSSC SECTION 1006.3.
Plumbing Requirements
PER TABLE 29-A
B OCCUPANCY 1:200, 6792 SF = 34 OCC = 17 MALE, 77 FEMALE
S1 OCCUPANCY 1:5000, 2301 SF = I OCC = I MALE, I FEMALE
LAVATORIES
WATER CLOSETS
REQUIRED
I MALE, 1 FEMALE
2 MALE, 2 FEMALE
t
PROVIDED
1 MALE, 1 FEMALE
3 MALE, 3 FEMALE
DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN
PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE
BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS
HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE
BUILDING. THE DEFERRED SUBMITTAL DOCUMENTS SHALL NOT BE INSTALLED UNTIL THE
SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL.
NOTE: SUBMIT SHOP DRAWINGS FOR REVIEW OF DESIGN INTENT COMPLIANCE PRIOR TO
FABRICATION OF THE FOLLOWING
1. INTERIOR PLUMBING SYSTEM
2. ELECTRICAL SYSTEM
3. MECHANICAL SYSTEM
cc
A. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS.
NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO START
OF WORK.
B. ALL HARDWARE IN ACCORDANCE WITH ANSI 117.1.
C. PROVIDE (1) APPROVED FIRE EXTINGUISHER WITH RATING OF
NOT LESS THAN 2-A:10B FOR EACH 3,000 SQ.FT, OF FLOOR
AREA TRAVEL FROM ANY PORTION OF BUILDING NOT TO
EXCEED 75`. FIRE EXTINGUISHERS NEED TO BE NEAR EACH
REQUIRED EXIT AND EVERY SEVENTY FIVE FEET ALONG THE
PATH OF EGRESS.
D. ALL FINISHES (IE BASE, ETC.) TO MATCH EXISTING UNLESS
NOTED OTHERWISE,
E. COORDINATE LIGHTING AND MECHANICAL FOR REVISED AREAS
WITH BUILDING OWNER.
F. VERIFY POWER AND DATA REQUIREMENTS WITH OWNER.
G. FURNISH THREE SILENCERS FOR SINGLE ACTING SINGLE DOORS.
H. DO NOT PLACE OPPOSING ELECTRICAL OR DATA MUDRINGS WITHIN
SAME CAVITY.
I. WOOD STUDS AT CONTRACTOR'S OPTION.
J. PROTECT ALL EXISTING CARPET DURING CONSTRUCTION.
KC REMOVE AND STORE ALL DOORS AND FRAMES IN LOCATION
INDICATED BY BUILDING OWNER U.N.O.
CITY OF TIGARD
Approved ....... ...................
q --
Conditionally Approv d ..............
See tt r to: Follow... .......
AI tats h ca
it r:
Address: _7 i
33,
RIM111-1 �
1.
REMOVE ALL EXISTING FURNITURE THIS ROOM
2.
NO DEMOLITION THIS ROOM
3,
REMOVE ALL EXISTING FURNITURE THIS ROOM
U.N.O.
4.
EXISTING CASEWORK TO REMAIN
5.
EXISTING DOOR, FRAME AND HARDWARE TO BE
RELOCATED
6.
EXISTING RELITE TO BE RELOCATED
7.
REMOVE ALL FURNITURE AND WORK STATIONS
THIS AREA
B.
REMOVE AND RELOCATE EXISTING COFFEE BAR,
SINK AND
UPPERS
9,
REMOVE FOLDING DOOR AND TRACK; STORE IN
LOCATION
AS DIRECTED BY BUILDING OWNER
10.
EXISTING STRUCTURAL COLUMN
11.
REMOVE EXISTING GLASS BLOCK
12.
REMOVE EXISTING WINDOW
13.
REMOVE EXISTING RECEPTION DESK
14,
REMOVE EXISTING TOILET AND LAVATORY AND
CAP OFF
15.
REMOVE EXISTING SINK
I:Demolition Plan
t
MILDREN DESIGN GkIOUP, P.C.
7650 SM, B eliand. St -lite 12()
T gai-d, T' '(:T2 972' 2? -8692
U` v 3" 244-055 �2
McCormack
Properties
7190 SW Sandburg St.
Tigard, Oregon 97223
Project:
t
MIEDREN DESIGN GROUP, P.C., 2013, ALL
RIGHTS RESERVED D
THESE DRAWINGS ARE THE PROPERTY OF
MA.DREN DESIGN GROUP, P.C., AND ARE
NOT TO 9E USED OR REPRODUCED IN ANY
MANNER, EXCEPT WITH THE PRIOR WRITTEN
PERMISSION OF MILDREN DESIGN GROUP, P.C.
Lute: 4 September 2013
Drawn by: Checked by:
BK WE
Job Number: 112029.06
(1) #14 SCREW
1
1
X10'-0" MAX,
WASHER 16 GA. x 4" x
.3" AT SCREW
#10 SCREWS
5./8" GYP BD AT
EACH SIDE SECURE
TO STUDS WITH
TYPE 'S' SCREWS
AT 5"-7" O/C
#16 WOOD SCREW
x 2" OR '5/jr," LAG
3" = 1,-0"
1b1a-r5
#12 WIRE TO TOP TRACK AT
6`-0" O/C NOTE; PROVIDE
3 ,5"x25 GA. DIAGONAL KICKER
AT 12`-0" O/C FOR ERECTION
(ALT. DIRECTION); TIGHTEN
WIRE AFTER WALL IS PLUMBED
SUSPENDED CEILING
J CASING BEAD
24" O/C
STUD
CHART;
362
S
125-18
TO
9'-11
"
-362
S
137-33
TO
17`-6"
400
S
162-33
TO
19'-10"
600
S
162-33
FO
279-7P,
SEE
AIE
FOR
ALTERNATE
SIZES
4" RUBBER BASE. TYPICAL
POWER -ACTUATED FASTENERS°
0.145" 0x '3" MIN. EMBED AT
12" O/C'
WALL TO 228-0"
2.145" 0 x 4" MIN, EMBED AT
6" Of C, WALL TALLER THAN
2 9 99
ndeCf
teilinq
t,
Floor Plan
a
. S v. S2S ,3}.,\y„ \
M 1 A f" T I fl ( A® E f A t A -T-r— r— A /I r—
0
i
i
0
SIZE HEQUIHEMEN I S
�00
c
` s
s
S t
i
x=1. -O.
3d -r2
NO BASE
TE HOT &
vvA� I L (,UNTINUE
FLOORING AND BASE UNDER
SINKP• MIN. CLEAR SPACE
WIDTH ALLOWABLE IS 2'-699
SHIM CABINET
BOX AS REOUIf
Legend
0 EXISTING DOOR
ROOM NAME
OFFICE ROOM NUMBER
ROOM AREAAOAD 101 ROOM FINISH
FACTOR B4BB9
XXX/l OO: 2--_ NUMBER OF
B. 2 E (TS OCCUPANTS
OCCUPANCY GROUP PER NUMBER OF
IBC TABLE 1004.1,2/NUMBER EXITS PROVIDED
am m0ml-or
1, 2x7' TEMPERED RELITE„ MATCH EXISTING
2, RELOCATED EXISTING COFFEE BAR, SINK AND UPPERS;
ADJUST CASEWORK ACCORDINGLY
3. CONCRETE SLAB WITH THICKENED EDGE
4. STOREFRONT OR GLASS BLOCK PER BUILDING OWNER
DIRECTION
5, RELOCATED DOOR, FRAME AND HARDWARE
6, RELOCATED TEMPERED RELITE
7. COORDINATE WITH OWNER THE REMOVAL OF EXISTING
CARPET IN THIS AREA FOR CARPET PATCHING; REPLACE
WITH NEW CARPET, STYLE & COLOR TBD
& COORDINATE WITH OWNER THE REMOVAL OF EXISTING
CARPET AND PATCHING CARPET WITH REMOVED CARPET
9. WALL TO ALIGN WITH DEMOLISHED WALL
10. EXISTING STRUCTURAL COLUMN
11, PLASTIC LAMINATE COFFEE BAR WITH SINK AND UPPERS
- SEE DETAIL 2/A3
12, PATCH GYPSUM BOARD CEILING AS REQUIRED
13. PROVIDE SUSPENDED ACOUSTIC TILE CEILING TO MATCH
EXISTING
14. FUR EXISTING COLUMN TO 10"x1O" FINISHED SIZE TO
BOTTOM OF SUSPENDED CEILING
Wall
EXISTING WALL TO REMAIN
EXISTING WALL TO BE REMOVED
NEW WALL
2'- 1 "'
1Y2"°=1` -O„
19o4 -r2
d-6410—cosawork—bola cobinat with drawer
Fill
�2WIN
at.
CONTINUOUS
FRENCH CLEAT
MOUNTS TO IN -
WALL BLOCKING.
(TWP) 3/4" MDF
ADJ. SHELVING
MELAMINE FINISH.
3/4" MDF DOORS
COVER BOTH FACES
AND EDGES W/
PLASTIC LAMINATE
MELAMINE INTERIOR
WIRE PULLS TYPICAL
Vpp�r
tf' Cabinet
vd- 647 0- casework- upper cab[net
00
E
%,P PLYWOOD WITH PLASTIC
LAMINATE. ATTACH TO STUDS
WITH (2) 2y2" TYPE S BUGLE
HEAD SCREWS, COUNTERSUNK.
SET IN SEALANT BED
NOTE: HIGH DENSITY PARTICLE
BOARD MAY BE SUBSTITUTED
FOR PLYWOOD UPON
ARCHITECT'S REVIEW
%" PLYWOOD WITH PLASTIC
LAMINATE AT COUNTER IOP
AND EDGE, ATTACH TO
SUPPORT W/ #10 x 2"
SCREWS AT 6" O/C ,
COUNTERSUNK
INSULATE PIPES
SASE CABINET AT
`SON -ACCESSIBLE PORTION
)NLY
MILDREN DESIGN Gpoup, w.
''kRC I UHC L.0 T 3_'tlC I'•: 'SPACE PLANNING
7650 -SAV. Bev€',land, ,111th . 0
as c 1! - "Y .... Lt00
7190 S' Sandburg St,
Tigard, Oregon 97223
Revisions:
MILDREN DESIGN GROUP, P.C., 2013, ALL
RIGHTS RESERVED Q
THESE DRAWINGS ARE THE PROPERTY OF
MILDREN DESIGN GROUP, P.C., AND ARE
NOT TO BE USED OR REPRODUCED IN ANY
MANNER, EXCEPT WITH THE PRIOR WRITTEN
PERMISSION OF MILDREN DESIGN GROUP, P.C.
Date: 29 August 2013
Drawn by: Checked. by:
BK WEM
Jab Number: e 112029,06
Sheet