Loading...
Permit r .t CITY OF TIGARD MASTER PERMIT • COMMUNITY DEVELOPMENT Permit#: MST2015 00130 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/30/2015 Parcel: 2S109DD10300 Jurisdiction: Tigard Site address: 12709 SW REMBRANDT LN Subdivision: BELLA VISTA Lot: 33 Project: BULLOCK Project Description: Window installation. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $800.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Typos Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add.'500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: BULLOCK,MOSES S BULLOCK,MOSES Required Items and Reports(Conditions) 12709 SW REMBRANDT LN 12700 SW REMBRANDT LN TIGARD,OR 97224 TIGARD,OR 97224 PHONE: PHONE FAX: Total Fees: $113.29 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a cop of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332 Issued By: rmittee Signature: Ca . 39.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Applicatio i 'C \V i% Residential I t►i t►hIl( I I SF ON I.1 City of Tigard ,U` 16 2015 DatcfB i1 Permit No.: !))CT )(S_,_ytl • 13125 SW Hall Blvd.,Tigard,OR 97223 ��yy Plan Rev' •• (�CJ� ( l.lt • I, �` 4LV .� Other Permit t,S Q Phone: 503.ine: 5 39 Fax: 503.598.1960 V�, l��A Date/B : r,ti a �. .U i t �`t Inspection Line: 503.639.4175 �11� �`,1Clo� Date ReadyBy: , 1 ® . ••Page 2 for Internet: www.tigard-or.gov 1ts1CgD i " Notified Method: � � �� � Supplemental Information TYPE OF WORK Permit fees"art based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑New construction ❑Demolition equipment,materials,labor,overhead,and the profit for the ©Addition/alteration/replacement ❑Other: work indicated on this application. CATEGORY OF CONSTRUCTION Valuation: $ 800.00 © I-and 2-family dwelling ❑Commercial/industri al Number of bedrooms: 0 Accessory building ❑Multi-family Number of bathrooms: ❑Master builder DOther: Total number of floors: JOB SITE INFORMATION AND LOCATION New dwelling area: square feet Job site address: 1 2709 sw Rembrandt lane Garage/carport area: square feet City/State/ZIP: Tigard, Or. 97224 Covered porch area: square feet Suite/bldg./apt.no.: Project name: �QLi//OC,(;( Deck area: square feet Cross street/directions to job site: S•� Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Permit fees*are based on the value of the work performed. Subdivision: Lot no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the Tax map/parcel no.: work indicated on this application. DESCRIPTION OF WORK Valuation: $ Legalize window Existing building area: square feet New building area: square feet Number of stories: © PROPERTY OWNER I ❑TENANT Type of construction: Name: Moca2,5 8 ut(`pd4 Occupancy groups: Address: 12709 sw Rembrandt Lane Existing: City/State/ZIP: Tigard, Or. 97224 _ New: Phone:( ) Fax ( 1 BUILDING PERMIT FEES* © APPLICANT 111 CONTACT PERSON (Please refer to fee schedule) Business name: Projective Const Design, INC Structural plan review fee(or deposit): Contact name: Terry Hellem FLS plan review fee(if applicable): Address: PO Box 6542 Total fees due upon application: City/State/ZIP: Beaverton, Or 97007 Amount received: Phone:( 503-270-6128 Fax: :( ) PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail: probUlld101 @gmall.COm Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. CONTRACTOR Submit two(2)sets of roof plan with connection details Business name: and fire department access,along with the 2010 Oregon � ti�✓� Solar Installation Specialty Code checklist. Address: Permit Fee(includes plan review City/State/ZIP: and administrative fees): $180.00 Phone:( ) Fax:( ) State surcharge(12%of permit fee): $21.60 Total fee due upon application: $201.60 CCB lit.: This permit application expires if a permit is not obtained Authorized signature: — / ��, * within 180 days after it has been accepted as complete. !/ Fee methodology set by Tri-County Building Industry Print name: Terry Hellem Date: 7/16/15 Service Board. REQUIRED DATA:1-AND 2-FAMILY DWELLING , I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB) 1 2 I 3 • % : a., ZI47 General Property Information 4 '" ' r Site Address: 12709 SW REMBRANDT LN. TIGARD OR, 97224 4 Ago 1.1`' .t ° Tax Lot ID: 2S109DD10300 Property Account ID: R2137633, CEWEP i .'h4 "' ,, ,, STEP To i z:, AT- • 47.71' — Add a new MSTC42 0�n OFw tObo� JUL 16 2015 mit M strap at corner cetered tp�� CITY(*TIGARD on f bor line - --------- - BUILDING DIVISION --)'-‘+''''Elltrg. \ -"------„,,..„..... 9.,A I8 ( 2,-0. A �, _ ToW Jr 64.97' Area of W. _ 217'4" ' (N) ■H= i'k 3x4 4 u, SH - E) - ,. 5'-0"IritiAr LTT ��`�� 1FFF 98.11' New window location—(E) - �— - 009'4" �1 zae�a• r tea, I 200 ..... CITY OF TIGARD '— . REVIEWED Z OR CODE COMPLUANCB 0 Right Elevation Appro edt 1 4- (E)Driveway Scale: 1/8" = l '-0" Legal: BELLA VISTA LfitiAt 1 1 85.69' Lot Size: A&T Acres: 0.1t#h v T-�_oc _co (mod l Code summary: Bldg Sq Ft: 2950Addres� 2--70 R t b�15 • 2011 ORSC ch 6 (S)11 Year Built: 2005_ 1 precriptive lateral wall brace method Suite#t B7 � l Da 7� �� Slte PIa n Perscrptive Shear Wall Per ORSC 2011 Section R602.10 r� LLL WSP to be Constructed in Accordance with Sections R602.10.2&R602.10.3 Scale: 1 "" = 20 ft PFH to be Constructed in Accordance with Section R602.10.3.3 Project summary: B OFFICE COPY Legalize new window add to NE corner side elev. B Pg - 1 Cover/Elevation Pg - 2 Wall plan/wall brace plan / I / I Design Firm Project Title Project Manager Project ID \\ \\ Projective Bldg. Design, LLC Rembrandt TH i/ \ / �\ P.O. Box 6542 Beaverton, OR 97007 12709 SW Rembrandt Ln Drawn By Scale i �ti i \� probuild101@gmail.com Tigard, OR 97224 CD T -I 1--1 I- f- http://www.probuildingdesign.com Reviewed By Drawing No TH 1 1 / 1 I Consultant Drawing Title Date . \ / \ / \, Site Plan/Elecation of CAD File Name `4. ./ 1 am/ \� i i/ 4 1 I 2 I 3 1 I 2 I 3 A. /\/ 1/2x10 Anchor Bolts 0 4'OC and 12"from ends —ads 7\r go Cont.PT 2x6 (N) Window to be Cont.(3)*3 Noriz.Reber ---r- , Legalized °'-4 i (N) 3'x4' w/ (2) 2x8 Header A A , , 1 1 2'-0-' i / / 221 , .. 0 Foundation Detail Scale: 1/4" = 1 '-0" 1\ Floor Plan } Scale: 1/4" = 1 '-O" E;1+ Perscriptive Shear Wall Per ORSC 2011 Section R602.10 WSP to be Constructed in Accordance with Sections R602.10.2 & R602.10.3 PFH to be Constructed in Accordance with Section R602.10.3.3 /,- G /\/ rid line #1 : - WSP-Wall brace (Side to Side) WSP brace panel: - Total length 21 ' 4'-0 width 15/32 APA osb/ply conn w/ - Min wall brace required: 13'-6" 8d @ 6/12, edges blocked and nailed. ' - - Actual wall bracing provided: 14' MSTC42 ' ` WSP WSP WSP 1 _ PFH B 2'-0"� 4'-0" 4'-0" I 4t-Orr 2 21 jr �"�, /- B 0 Shear-Wall Plan Scale: 1/4" = l '-0" --.- --- I -. ---- I . Design Finn Project Title Project Manager Project ID `\ Projective Bldg. Design, LLC TH / �\ / �\ P.O. Box 6542 Beaverton, OR 97007 Drag,By CD sale �� �� I� \� probuild101 @gmail.com Portland, OR T H I--1 I- +" http://www.probuildingdesign.com Reviewed By TH Drawing 1\ / 1\ / Consultant Drawing Title Date 2 / \ / lateral wall brace of \ / \ / CAD File Name ■`_ I Jam/ \ . l mo/ . 1 I 2 I 3