Loading...
Plans tke� 1,. , , !...... 2014 C : • ;� 1.0 CITYOFTIGARD r {q 4 ' C. }° BUILDING DIVISION , •:, , 14100 .. r - •r v 1111 ,, . ... ... '}..31147§ 'I: _:: ss • City of Tigard __ . ,- App oved Plans ...: ..........._..._...» ,.. ...... By ,sz Date _... •.».4_., ...-.»»»-. . ...» _-. X4-24& Gt4 - n� ' WASHINGTON SQUARE MALL ,„ REVISION I b OFFICE COPY ----»--.- _ „ » i..............» . _._„ 54 n , 1 . _ w.www..,, 6 _. •, , 9585 Sw WASHINGTON SQUARE RD. __.__ .. N- o .. _.._..._._....»..__ T � � ., �� = A SPACE NO. K05 w_w I PORTLAND, OR 97223 _ _. ..»».»._ I--- --- w Al3BREVIAT1ONS PROJECT DATA SITE LOCATION PLAN DEFALJED SCOPE OF WORK A.F.F. ABOVE FINISHED FLOOR JT. JOINT 1 PROJECT NAME. HOT TOPIC # 422A PROJECT SCOPE: EXISTING HOT TOPIC SPACE TENANT REMODEL REMOVE STOREFRONT AND SALES AREA FIXTURES. ` .,.,-_. A.F.C. ABOVE FINISHED CEILING MFR. MANUFACTURE (R) REPLACE WITH NEW. ALTER UGHTING AS REQUIRED & SHOWN. HVAC & ELECTRICAL TO REMAIN, A ww� AC.T. ACOUSTICAL TILE MECH. MECHANIC (AL) 2. PROJECT DESCRIPTION: . CLOTHING SALES (RETAIL) - INTERIOR REMODEL OF EXIST. TENANT SPACE MINOR MODIFICATIONS AS NOTED IN THIS PLAN SET. MINOR SPRINKLER MODIFICATIONS. s ADJ. ADJACENT MTh. METAL 3. PROJECT LOCATION:. WASHINGTON SQUARE MALL SW DENNEY RD ALT. ALTERNATE ME/Z. MEZZANINE 9585 SW WASHINGTON SQUARE RD. APPROX. APPROXIMATE MIN. (') MINIMUM, MINUTE PORTLAND, OR 97223 7.„..... -..»_ _,.,........-.s.-.-.» ARCH. ARCHITECT (URAL) MISC. MISCELLANEOUS BLK. BLOCK N.I.C. NOT IN CONTRACT 4• TENANT:• HOT TOPIC GARDEN HOME RD ��++��pp//�� /I�N�G BLKG. BLOCKING N.T.S. NOT TO SCALE RJP CONSULTING GROUP, LLC. D.z.) 'TV1��IwRa Nf��EX BD. BOARD NO. or f NUMBER 112 E. LANCASTER AVENUE, FIRST FLOOR _ wxi.:rc:ii :ivrciiiiv :,xv::i:w:;::.i,.vw:,,:}wwirce:xn:j r. S CLG. CEILING O.F.C.I. OWNER FURNISHED CONTRACTOR DOWNINGTON, PA 19335 2V.i/SW �G0 SHEET DESCRIPTION REV DATE CLG.HT. CEIUNG HEIGHT INSTALLED (610) 518-2930 EXT. 17 d' ......rc...__ w.__. ... __ _...... CLR. CLEAR (ANCE) O.F.0.1. OWNER FURNISHED OWNER .. CONTACT: JASON ADAMS (MANAGER OF CONSTRUCTION) WASHINGTON �''4 1 T TITLE SHEET Q 08/18/14 CLO. CLOSET INSTALLED EMAIL: jadamsOrjpconsultinggroup.com ' SQUARE MALL COL COLUMN O.C. ON CENTER (S) '` C.M.U. CONCRETE MASONRY UNIT OPP. OPPOSITE 5• DLO MACERICH COMPANY �� 2 D1 DEMOLITION PLAN Q 08/18/14 CONST. CONSTRUCTION P. L PLASTIC LAMINATE 11411 NORTH TATUM BOULEVARD �,� COORD. COORDINATE PLBG. PLUMBING PHOENIX, AZ 85028 1-- 602-953-6750 v CORR. CORRIDOR PWD. PLYWOOD � 3 Al A 1 FLOOR PLAN © 08/18/14 C I i ONTACT: AARON PRATT, TENANT COORDINATOR w.,....,. �. .. CTR. CENTER PVC. POLYVINYL CHLORIDE EMAIL: aaron.prattOmacerich.com `' 4 A2 REFLECTED CEILING PLAN A 08/18/14 C.T. CERAMIC TILE P.M. PROJECT MANAGER 5 A3 INTERIOR ELEVATIONS Q 08/18/14 » . �..... ».w DET. DETAIL RA RETURN AIR 6. TENANTS ARCHITECT:. ARCVISION INC. m DIAG. DIAGONAL R.C.P. REFLECTED CEIUNG PLAN 1950 CRAIG RD. - SUITE 300 6 A4 GENERAL SPECIFICATIONS Q 07/11/14 ..., DNA. DIAMETER REF. REFERENCE ST. LOUIS, MO 63146 7 A4A GENERAL SPECIFICATIONS Q 08/18/14 J � 8 • ; ' I ► ' i k L ATION Q 08/18/14 rcrcw. Q NDIE. DIFFUSER REG. REGISTER 314-415-2400 . b w:w:DIM. DIMENSION REINF. REINFORCE (D), (ING) CONTACT: GREG WINCHESTER m 08 18 1 4 ».......... _°.rcM_. .- ` ___ "'' "�"DISP. DISPENSER REQ D. (REQ.)REQUIRED 9 A5A STOREFRO T E TI N © © / / �.7. BUILDING DEPARTMENT: !CITY OF TIGARD BUILDING DEPARTMENT A . L� I PLAN Q 08 1 DR. DOOR REV. REVISION (S), REVISED 13125 SOUTHWEST HALL BOULEVARD • DWG. DRAWING R.O. ROUGH OPENING TIGARD OR 97223 101 A7 NOT USED Q 03/1$/13 w g■ w»�».. » w.� �a ELEC. ELECTRICAL SHT. SHEET 503-718-2436 12 A8 SECTIONS & DETAILS Q 07/11/14 `d a E.P. ELECTRIC PANEL SIM. SIMILAR CONTACT: DAN NELSON _ • • ELEV. ELEVATION S.C. SOLD CORE 13 A9 FITTING ROOM ELEVATIONS & DETAILS Q 07/11/14 s, ; H' 8. GOVERNING CODES: . ALL WORK SHALL BE IN CONFORMANCE WITH, BUT NOT LIMITED TO, �. £.may... .�,......�.:.. E.W.C. ELECTRIC WATER COOLER S.S. STAINLESS STEEL „rww.w....I�d.�......».� THE REQUIREMENTS OF THE FOLLOWING: AND ANY OTHER STATE AND N EXIST EXISTING STD. STANDARD H N f LOCAL CODES HAVING JURISDICTION. Z EQUIP. EQUIPMENT STL. STEEL 1 .. 14,4'3 .» EXH. EXHAUST STO. STORAGE BUILDING: 2010 OR STRUCTURAL SPECIALTY CODE SPACE LOCATION PLAN 0 .. °' O# EXP. JT. EXPANSION JOINT S.D. STORM DRAIN PLUMBING: 2011 OR PLUMBING CODE .-..°,..µl♦♦--�-' '--} ---E- �y�.. »``» FIN. FINISH (ED) STRUCT. STRUCTURAL MECHANICAL 2010 OR MECHANICAL CODE v I Q - - F.E. FIRE EXTINGUISHER SUSP. SUSPENDED FIRE: 2010 OR FIRE CODE - ww -- I B s FP. FIREPROOFING T.B.D. TO BE DETERMINED ELECTRICAL 2011 OR ELECTRICAL CODE JC PENNEY �irt„ - „ !_„.....„ F.D. FLOOR DRAIN TEL TELEPHONE ENERGY: - a FLUOR. FLUORESCENT T5. TUBE STEEL 9. TYPE: 11_B ._.__., a mow,.»»,. . Q µ._ F.R.T. FIRE RETARDANT TREATED TYp. TYPICAL =uric FURR. FURRED (ING) U.N.O. UNLESS NOTED OTHERWISE 10. OCCUPANCY: to (MERCANTILE) SPACE #K05 WI GA. GAUGE VERT. VERTICAL GALV. GALVANIZED VEST. VESTIBULE 11, GROSS LEASED PREMISES: . . . . 9,809 SQ. FT. G.C. GENERAL CONTRACTOR V.C.T. VINYL COMPOSITION TILE 12. OCCUPANCY LOADS SALES FLOOR 1,419 SQ. FT. DIVIDED BY 30 = 47 _ I GYP. BD. GYPSUM BOARD V.I.F. VERIFY IN FIELD H.V.A.C. HEATING/VENTILATION/ FITTING ROOM 54 SQ. FT. DIVIDED BY 30 = 1 DICK'S I . AIR CONDITIONING W.C. WATER CLOSET STOCK ROOM 251 SQ. FT. DIVIDED BY 300 = 1 H.C. HOLLOW CORE WP. WATERPROOFING) WS. WEATHER STRIPPING HALLWAY 85 SQ. FT. H.M. HOLLOW METAL TOTAL OCCUPANTS = 46 .- o HORIZ. HORIZONTAL W/ WRH * TOTAL NUMBER OF EMPLOYEES AT ONE TIME = JL 3 H.W. HOT WATER W/O WITHOUT 13. ' IN.(") INCH WD. WOOD 14. F RE SUPPRESSION SYSTEM:. . . . YES 30 NO ❑ r o o i § INT. INTERIOR r I �-r § p, MISCELLANEOUS NOTES:, TENANT'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND VERIFY j ° ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION AND SHALL -2— HOT TOPIC PRE/POST PUNCHUST 15 rf o ICs REPORT ALL DISCREPANCIES TO TENANT'S ARCHITECT. TENANT'S GENERAL I I g , CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING CONSTRUCTION PROCEDURES, INSURANCE, ETC., AS SET FORTH BY THE T� DETAIL NUMBER ROOM NUMBER 15. LANDLORD. �_ —L J Ste' 1. DOES FRONT DOOR AND BACK DOOR HAVE A 7-PIN CYLINDER FOR HT PROVIDED CORES? W,- - °O alk MACY'S 2. IF NOT ALREADY EXISTING, GC TO FURNISH AND INSTALL A PEEP HOLE AT 5'-0' AFF IN BACK DOOR c FIRE SPRINKLERS: AN AUTOMATIC FIRE SPRINKLER SYSTEM IS EXISTING WITHIN THIS SPACE. 3. GC TO INSTALL A PRY PLATE ON BACKDOOR IF NOT EXISTING --w•- SHEET WHERE �� KEY NOTE ® THE CONTRACTOR SHALL REWORK AND MODIFY FOR NEW ROOM LAYOUT v 4. GC TO FURNISH AND INSTALL A NEW BATTERY FOR THE DETER IN BACK DOOR ` .�■DETAIL IS SHOWN & CEIUNG HEIGHTS IN CONFORMANCE WITH N.F.PA. 13 STANDARDS & 5. GC TO INSTALL SECURITY MIRROR IN LOCATION DIRECTED BY HT OPERATIONS TEAM ,_. �....»....»... 3 PARTITION TYPE © LOCAL CODES & REGULATIONS. ALL WORK SHALL BE DONE BY A QUALIFIED 6. GC TO INSTALL 2 INK TAG DETACHERS IN CASHWRAP W SECTION CUT MOO SPRINKLER CONTRACTOR WHO SHALL DESIGN & PREPARE SHOP DRAWINGS 7. GC TO INSTALL METAL STRAPS ON FRONT OF CASHWRAP AND BACKWRAP �, ! & SUBMIT THEM TO THE LANDLORD FOR APPROVAL PRIOR TO FABRICATION 8. ORK BOARDS TO BE INSTALLED IN THE BACK ROOM/HALLWAY BY GC AT STORE OPERATIONS DISCRETION a u u CI I CO DOOR NUMBER & INSTALLATION. SPRINKLER CONTRACTOR SHALL BE LANDLORD APPROVED. 9. ;AC STICKERS AND SIGNS TO BE INSTALLED BY GC ON CASHWRAP, FRONT WINDOW, AND FITTING ROOM NORDSTROM 11110435.... CKING COVER ON THERMOSTAT 0 W BUILDING CROSS 4 11. TO SUPPLY 8 KEYS FOR FITTING ROOM DOORS (IF MULTIPLE FITTING ROOMS, EACH DOOR IS TO BE KEYED ALIKE) '� LI SECTION A100 DOORTKNV BENCHMARK 12. TO CAULK AROUND FITTING ROOM BENCHES AND BASE BOARDS WITH CLEAR SILICONE N HANGER TfrE TO BE INSTALLED IN BACKROOM PER HT OPERATIONS TEAM DIRECTION 0 IF WE ARE REUSING AN ADA FITTING ROOM, GC TO ADD A FITTING ROOM HOOK AT 48' NEXT TO FITTING ROOM BENCH ° ELEVATION A1400 REVISION NUMBER Q SLATWALL SCREW CHECK. MAKE SURE HARDWARE SLIDES FLUSH ALONG SLATS WHERE SCREW HEADS STICK OUT. _ T LEVEL: 1 OF 2 4 # c 3 i tkit 0 i ,.-4t» p S m to 1 EXISTING EXIT1 EMERGENCY °' LIGHTING AT STOREFRONT TO `• - ''' t . BE RELOCATED TO NEW SOFFIT �� c' 4' EXISTING TRACK T,0 EXISTING CASHWRAP TO BE G.C. TO REPLACE WITH NEW AS _ * ua i BE RAISED TO 13-0 AFF REMOVED - G.C. TO VERIFY REQUIRED ,-. ........,, . ...r .., °t4 .n.. EXISTING SERVICE DOOR '_ �� TO REMAIN - G.C. TO EXISTING POWER STUB-UP G.C. TO RELOCATE THERMOSTAT TO d�� REP.ACE HARDWARE AS EXISTING GYP. BD. CEILING LOCATIONS BELOW AND EXTEND EXISTING PENDANT LIGHTS STOCKROOM & PROVIDE REMOTE SENSOR EXISTING DEMISING EXJSTIUG ACT CEILING 0 LEASE LINE EEXISTINGG SOFFIT »..._ J ak REp D - SEE HARDWARE TO REMAIN TO NEW LOCATIONS AS REQ D OVER CASHWRAP AREA TO IN SALES AREA CONFIRM REQUIREMENTS/ WALL TO REMAIN 15-6 AFF TO REMAIN SCHEDULE TYP. FOR BOTH SIDES BE REMOVED - TYP. OF 6 LOCATIONS ONSITE W/ HOT TOPIC P.M. EXISTING NEUTRAL I - - - - - - PIER TO REMAIN .. , . �• � - - - I - - EXISTING RECEPTACLE f f r T - - - - - - - - - - EXISTING STOREFRONT 411 : f f• GLAZING TO REMAIN • �� . : • -. • • ' :j' %∎ I ' • I �i a (STING STOREFRONT J ; LEASE LINE ;• '.` .r .• • ' r . '' ; — — LIGHTING TO REMAIN .». .._• EXISTING DEMISING \ ■ffig�� =�� M� + ., WALL TO REMAIN l■' :■ I, 31 1• ,' , 3' _ . ;. or—HEAD TO RE r r �• • U.N.O. EXIST. FIRE SPRINKLER . ........ r _ _ HEAD TO REMAIN - TYP. �»m�. �. ......... `�..... _.......imal EXISTING DOOR TO IXI NG FLU a REUCE I- ' . REMAIN - G.C. TO U.N.O. g ..»...... EXISTING SPEAKER U NG TO E REM• D I 3 REPLACE HARDWARE �� REMOVE EXISTING SUBSTRUCTURE ENTRY •c AS REQ D - SEE TO BE REMOVED MIMI HARDWARE SCHEDULE PORTAL AN '' »•• STI G ACT CEILING ® EXISTING TRACK HEADS IXISTIN• SMOKE DETECill!15-6� AFF TO REMAIN TO BE REMOVED TYP TO BE 'EMOVED . — t _ L— r : r- t�`• ; > PO RT10N 0 EXIST( G CK TO - -T r- . �' _./ NO WORK SIATWALL -0 BE R OVED 0. `L� XISTING SENSOR TIC' TO BE DOSE EDEST TO BE REMOVECI I I I I ' • o � FCR NEW CONSTRU ON ��` I »..»».»». ; � ».»..... i ,, �,, I I 1 I I EXISTING STOREFRONT ROWNG • Cif Ca II GRILLE TO BE REMOVED »..».., f . f; r,' PORTIO OF EXI' �� EXISTING RECEPT _iH f f FITTING ROOM W. iuz: v r I- TO REMAIN - TYP.• '' OVED%r .. . . . _ . REMAIN TYP ...__•• • •.• 4 • • -- - r Cif Ai HEAD TO • _ I R OrED. .. WM a - DUSTING STOREFRONT I SENS•R TIC •' '� :U� �_ EXISTING STOREFRONT (STING F LORE a NT EXIST. FIRE SPRINKLER•' 1111- i. ,'. : { ► HTING R:l OVED HEAD TO REMAIN TYP. ► LIGHTING TO REMAIN �� _►.d i •' Kr ■ U.N.O 8 EXISTING NEUTRAI_• • ,. .. div►a PIER TO REMAIN » - - - - - EXISTING RESTROOM TO REMAIN EXISTING FITTING ROOM SCONCE EXISTING DEMISING LEASE LINE ' NO WORK TO BE DONE TO BE REMOVED- CAP ELECTRIC WALL TO REMAIN © - _ »._.. ...___.. PATCH AND PLANT GYP. B.D AS REQUIRED DEMOLITION PLAN EXISTING SOFFIT SCALD jd4 es f.. 5 — piiiir% EXISTING BRICK SOLDIER COURSE TO REMAIN Ark EXISTING STOREFRONT ..... . SIGNAGE TO BE REMAINT i EXISTING BRICK SOLDIER IITICOURSE TO REMAIN EXISTING BRICK VENEER EXISTING BRICK VENEER m .. ......_ ................._...... r...........WAIL TO REMAIN '/ WALL TO REMAIN _ 1 1 J 1 1 1 J l I t 1 I-1 1 t 1 1 1 , 4 1111111 ■111111/1/1/1 ,IN, 1 _� L _ f ._ . EXISTING RICKS I € rk E �� EXISTING BRICK SOLDIER ..... »_ .. ...... ., . (NI - \ EXISTING MALL BULKHEAD COURSE O REMAIN COURSE TO REMAIN _._.. .►. MI ■�pI ,PIR TO REMUAIN 1 EXISTING NEUTAL, � -• PIER TO REMAIN fcrl-Uri I 1EN Ic� TO REMAIN I n '- T w��� _-.. EXISTING BRICK VENEER I I EXIST. STOREFRONT I � ARCHWAY TO REMAIN I SECURITY GRILLE ..,■ TO BE REMOVED ■ E ............... ._.». EXISTING STOREFRONT GLAZING IL 11 REMOVE EXISTING I EXISTING STOREFRONT GLAZING __I SYSTEM TO REMAIN 1 1 I ENTRY PORTAL AND I == I SYSTEM TO REMAIN �j J� O; 1 I NE , i� 111 ILIA - 1 �E: !� ». ... ID EXISTING SENSORMATIC EXISTING BRICK VENEER M I I PEDESTALS TO BE REMOVED I 1 I ARCHWAY TO REMAIN EXISTING MDF BRICK SOFFIT TO REMAIN _ £: : ; 1 a ■ � \1 4 1 I •J\ <. .-I I SECURITY GRILLE f 1 1 a I I I SCALE 'V4' - f-O' ` I I II 1 I A DEMOLITION NOTES; W t 1 I I I 1 I 1. IN ALL WAILS AND CEILINGS THAT ARE REMOVED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR _ DISCONNECTIONS AT SOURCE AND REMOVING OR CAPPING ANY ELECTRICAL, PLUMBING, GAS, UNES AND I I I I TTY MECHANICAL DUCTWORK THAT IS DISCLOSED AND NOT SCHEDULED FOR REUSE. REROUTE AND CONTINUE ANY 1 =NI SYSTEM THAT MUST BE RETAINED FOR ADJACENT BUILDING AREAS THAT ARE NOT IN THE CONTRACT. I 1 1 I I I I I I DUSTING TO STOREFRONT GLAZING 2. ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE DISCONNECTED AT SOURCE Z , AND REMOVED a I 1 I I-I I 3. CONTRACTOR TO VERIFY CONDITION OF ANY EXISTING DOORS TO REMAIN. VERIFY CONDITION OF HARDWARE. - g 1 1 I I EXISTING MDF BRICK I I I I FINISH AND WALL TO REMAIN REPLACE IF NECESSARY. PROVIDE HARDWARE AS SPEC'D ON DRAWINGS. i 1 4. ALL GAS, WATER AND DRAIN UNES SUPPLYING EQUIPMENT THAT IS TO BE REMOVED SHALL BE 1 I I I I I DISCONNECTED, REMOVED AND CAPPED ABOVE CEILING OR BELOW FLOOR IF CONTINUITY OF SYSTEM MUST BE ° c I I MAINTAINED FOR USE BY ADJACENT AREAS, CONTRACTOR SHALL REROUTE, AS NECESSARY, TO BE BEHIND NEW 1 c - I I CONSTRUCTION. (PATCH FLOOR BACK PRIOR TO TOPPING) o I 5. G.C. TO VERIFY AND REMOVE ADDITIONAL ITEMS PER PLANS AS REQ'D. . z. 1 __ I I 6. GENERAL CONTRACTOR TO MAINTAIN THE INTEGRITY OF ALL ARE-RATED CONSTRUCTION. G.C. TO REPLACE W 03 n I 1 I I 1• G.C. TO VERIFY All DIMENSIONS WITHIN (1) DAY OF START OF PROJECT OR RELOCATE, IN ACCORDANCE W/ LOCAL CODES. ALL FIRE SUPPRESSION & ARE ALARM EQUIPMENT ^ 8 _`„TI„ -- .1 I &/OR BEFORE ANY NEW CONSTRUCTION BEGINS. ANY DISCREPANCIES TO BE DISTURBED BY DEMOLITION OR CONSTRUCTION. i I I 1 I I RESOLVED WITH HOT TOPIC PROJECT MANAGER PRIOR TO START OF FRAMING 7, REMOVE ALL DEMOUTION MATERIALS INCLUDING RUBBISH AND DEBRIS PRIOR TO NEW CONSTRUCTION. t a .4 ... » 0 OR ROUGH-IN. - -� ,»,. 8. REMOVE OR RELOCATE ANY SPRINKLER UNES AS REQUIRED, IN FIELD PER LANDLORDS'S AND/OR LOCAL N E DEMO SECTION 2. G.C. TO a _ a T —� AUTHORITY APPROVALS. 3 3. CONTRACTOR TO VERIFY, PRIOR TO BIDDING, COMPLETE SCOPE OF 9. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL CEILINGS, WALLS, AND FLOORS AS REQUIRED TO O 1/2' ■ 1-0' DEMOLITION. ALL REQUIRED DEMOLITION TO BE INCLUDED IN THE RECEIVE NEW FINISHES. (G.C. TO MAINTAIN 1-HOUR ARE RATED CONSTRUCTION THROUGHOUT TENANT'S SPACE k ` BASE BID. DEMOLITION PLAN IS ONLY AN ESTIMATE OF SCOPE WHEN REQUIRED). = i‘:1 W OF WORK. 10. TENANT G.C. TO VERIFY IF SENSORMATIC WIRING IS AT DEMO PARTITION OF ENTRY. IF EXISTING WIRE Q 4. ALL DEMOUTION WORK IS BY G.C. UNLESS NOTED OTHERWISE. FOUND, TENANT G.C. TO CONTACT SENSORMATIC FOR RELOCATION OF EQUIPMENT/WIRING ETC. AS REQUIRED. 5. G.C. SHALL CONTACT THE MALL OPERATIONS MANAGER & CONFIRM THE 11. EXISTING SLATWALL IN SALES AND STOCK AREAS TO REMAIN -REQUIREMENTS FOR THE STOREFRONT BARRICADE & PROVIDE ACCORDINGLY D1 I 1 I 7 - It-4'-' • ' 0 9 , i • I ce : ...:1 1 • ;� . .. . . 2 V` a, c�i 44 mm .. G ....., r+1 ADJACENT "- _ _ * TENANT _.». 81'-10 3/4" LEASE LINE DIM. 2co ~ _ u_........»» 12'-5" A.F.F. . - For\ 30 -3 8'-6" / 17 -2 / 5 -8 M I\ \ - - -- - - -- - - -- - - -- - - -- -- - - -- - - -- - - -- - - -- - - -- - - ; ; "- -- -- - -- \ \ — ..._........W.....,..,a ... _ __ I M #6 BLACK TRIM-HEAD SCREWS 0 6 O.C. HORIZONTALLY do EVERY 1� 3 SLATWALL SLOTS VERTICALLY, i i I __ 1 = 1 INSTALL NEW SLATWAU_SII- 3 \PER MANUFACTURERS INSTRUCTIONS i I I I I I ;n > O OVER DaIST. TIYALL EXISTING DEMISING " \ 6 I I * R!9KpZ �I/\ P-1 I I I \ SEE DETAIL 3 \ PARTITION M �' I EXISTING METAL STUD PARTITION i - - - _ J I L - i µ.......... _.rc: ..........,.m,.....m. M �, & GYPSUM BOARD TO REMAIN - - - - - - - J 1 • �`1 1 _ - INSTALL NEW SLATWALL ■ I -, .:'frtN. ,I I c° > ON EXISTING DEMISING :- EXISTING SLATWALL TO REMAIN © I S1r- o I I o _ ::: N ii., . w i . .. — _.......t EXI ING '�" `� . I I 6'-0" V.I.F. „ 6 t i _..__..— ! :. J L NEW 4'x8' OSB SLATWALL,631 N I I ISTOC ROOM , __ . . i i w • PRE-STAINED BY TENANTS L_ - r - -- - -I o ..._....._._.» •• MANUFACTURER J I 0 WORK THIS AREA I 1 1 "°""" ' N SALES AREA _I J , 4 CASH t 3 y..._.,...». i S. M L// I © 0 ` . I WRAP ' M j _' + ...:: p4 N EXIST! G , — �� I — ; £... -c., :11 r., m..g.-----J TOIL 'BOOM ), z 3 m.....m .. ' £ INSTALL \ \P i I I © £ `3 \ EXISTING DEMISING I = �I »» , r�/ o EXISTING SLATWALL TO REMAIN I I 4 I I I 1 I PARTITION i c � r7 cN :II; 1 1 L- - --J - - - EXIS ,G OUTLINE OF CASH / WRAP INSTALL NEW SLATWALL 'n 1' \� i SITTING R01 N INSTALL NEW SLATwALL� UNIT. SEE FIXTURE PLAN ON EXISTING DEMISING •I - - _ OVER EXIST. TWALL G.C. TO VM1FY EXISTING POWER ,_ _ `� MANUFACTURE SLATWAT �` F. I - - O SEE DETAIL 3 STUB-UP LOCATIONS FROM OLD _I 0.PARTMON i M\ „„„.L__ ___ _ _._... .... PRE-STAINED BY TENANTS CASHWRAP & WEND TO NEW in �►1 0 .••40, BY POWERPOLE AS REQUIRED _ _...:............. 16 BLACK TRIM-HEAD SCR 0 \ - - -- - -- - - -- - - -- - - -- - -- - - -- - - -- - i- 16 O.C. HORIZONTALLY & EVERY �� 3 SLATWALL SLOTS VERTICALLY F NOT EqpY I G G C. To I sTALL A ADJACENT I/\ PER MANUFACTURERS INSTRUCTIONS MAIN WA SH -0 �yj�VE AT E /\/\ LEVEL WITHIN TH R�M. TENANT ... _ ....m, _ .»n N _........ :,_- -:._ /b EXISTING METAL STUD PARTITION 3 ,., �: _�do GYPSUM BOARD TO REMAIN ._...».............»»......»_. -....__..._» I »...........;........_... %► FLOOR PLAN .._.._ /I 1 ' --- '���� 4” HIGH WOOD BASE OVER 5" WOOD • '/• - BACKING SCRIBED TO FLOOR. 1 1/4' • f-O' . _ F. FOR DOOR DESCRIPTIONS) ' - 8LA 'T ALL DElAIL SEE DOOR SCHEDULE, SHEET MA I SCALE: 3' - f-0' SALES: 1,419 SQ.FT. jNSESEES FITTING ROOM: 54 SQ.FT. » �.d.............4 .....W ».». .» »»»_ SLATWALL "SW-1': 59 SHEETS HALLWAY: 85 SQ.FT. 1. G.C. TO INSTALL STOREFRONT BARR E GRAPHICS SLAT STOCKROOM: 182 SQ.FT. �... .._....... ._...._.. ... .».... .... w...a SUPPLIED BY OWNER. COORDINATE W/ WALL "SW-2': - HOT TOPIC BRICK FLATS: - Q. . RESTROOM: 69 SQ.FT. PROJECT MANAGER. BRICK CORNERS: - QTY. TOTAL BUILDING: 1,809 SQ.FT. 1-1, ak 1. G.C. TO VEMFY ALL &EN 1 01*1 ' DAY OF0 Sri OF WALL PARTITION LEGEND d •4- OR MORE IINY NEW OONSIRUCt10N EEGINS. IW1f D�( MICAS ........_ '.. ....___ �... ..» STIR MINING RESOLVED OR GUESS U�l PROJECT WAVER PRIOR TO REIN DESCRIPTION W r NEW FULL HEIGHT PARTITION, MTh. STUDS & FINISH .... ------ LEASE UNE TO CEILING �.»..» .� I ENFRM1 NOTE' CONTRACTOR'S NOTES; ------- EXISTING DEMISING PARTITION NEW PARTITION, MIL. STUDS AND GYP. BD. ; i . I—I STOPS SHORT OF CEILING 1. CONTRACTOR TO INCLUDE IN BASE BID TO PATCH FLOAT OR REPLACE 1. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. m m<I ......-._ •�._._ • =_r. ... YP.GBOARY OR ON MISSING FOR AN "AS WHERE EW"GYP. IS FA DAMAGED, C DNO IT DEMO..MCONCONTRACTORS MUST VISIT JOB SITE TOPVVERIFY ANY LI GCI NEW DEMISING PARTMON - PER MALL CRITERIA NEW ONE-HOUR PARTITION Z, H N OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER DIECUTION OF ao 1,°�°"" 2. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. EXISTING PARTITION TO REMAIN x PARTITION TYPE - SEE SHEET Al - in jiff 50E DEM. CONTRACTORS MUST VISIT JOB SITE To To TENANT REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS O' AND BEFORE START OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB ".»........,,J. 1 w .N. .»»....__ VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS. OR CODE COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. © DOOR TYPE - SEE SHEET MA g Q I PARTITION TYPE PARTITION TYPE PARTITION TYPE ,STUD GA. LIMITING HT. SCHEDULE _ _ - _ .. 'NOT USED EXIST DECK EXIST DECK EXIST DECK A. TABLE BELOW IS BASED ON UNIVERSAL INDUSTRIES UNIMAST (USG) CORPORATION'S UMMNG Qa 2 HEIGHT TABLES FOR UNBRACED STUDS SPACED 16 AND 12 O.C. SYSTEM FOLDER ' - SALE NOT TO SCALE ±3T1 7 1/7'AF.E ± 317 7 1/7'AF.F. ± 30I-7 1/7'AF.F. SA-923-1990 DEFLECTION 9 -1 SEEEDITION),FLEIBLREQUIREMENT SWITH RI SLAYER OF GYP.BD PER AND OF 2ST40uU ALLOWABLE I _� (cc TO VLF.) (cc TO V.I.F.) (GC T>7 V.I.F.) €0 B. SCHEDULED HEIGHTS MAY BE INCREASED BY 50% WHERE THE STUDS ARE DIAGONALLY w ` BRACED AT THE MAXIMUM HEIGHT POINT TO THE STRUCTURE ABOVE 0 4-0' O.C. - EXIST ACT CEILING EXIST ACT CEILING EXIST ACT CEILING C ' WHEN USING STUDS MANUFACTURED BY A COMPANY OTHER THEN USG VERIFY I 0 15'-6' A.F.F. / 0 15-6 A.F.F. 0 15'-6" AF.F. �RERS STUD STRENGTH AND UNITING HEIGHT. ADJUST GAUGE AND MAXIMUM HEIGHT • G.C. T�"PATCH & FLOAT 5 8" G.C. TO PATCH & FLOAT 5/8' RECOMENDED BY MANUFACTURER'S CURRENT PRINTED SPECIFICATION. TYPE X GYP. BD. TO MAKE TO MAKE LIKE NEW MAINTAIN ALL Stud Stud Stud Stud Maximum Z w f UKE NEW. MAINTAIN ALL FIRE RATING REQUIREMENTS Width Type Gauge Spacing Height E°l — \FIRE RATING REQUIREMENTS —� " ' " a£g , 1-5/8" 158ST25 25 16 9-6 158ST25 25 24" 7'-3" `' )_1 m c, I INSTALL NEW SLATWALL INSTALL NEW SLATWAU. ° x$ c� ^OVER EXISTING SLATW/LL INSTALL NEW SLATWALL ........---INSTALL EXISTING SLAT / .L o FROM BASE TO 12 -5 A.F.F. ON WALL PARTITION FROM FROM BASE TO 12-5 A.F.F. 2-1/2" 212ST25 25 16 12'-611 g. o \ I BASE TO 12 -5 A.F.F. 212ST25 25 24" 10'-9" I EXISTING METAL STUDS 3 5`8" 20 Mm. EXISTING METAL STUD 212ST22 22 16' 13'-0' DEMISING WALL TO REMAIN 5�8 GYP. BD. STUDS AT 16�O.C. WALL TO REMAIN 2125T22 22 24" 11'-6" "' C G. TO BE EXTENDED BY G.C. - W - 1 ;n c� ON 6 20 G�. Mm. In 212ST20 20 16 14'-0" a - k I STUDS 0 16 O.C. 1 • z BY G.C. IN 212ST20 20 24" 12'-3" ~', ADJACENT TENANT/ TENANT SPACE w 5/8' GYP. BD. STOCK ROOM SAI FS AREA 3-5/8" 358ST25 25 16" 16'-0" .�i �� ..... ..._. Q MALL CORRIDOR = SAI ES AREA 358ST25 25 24" 13'-6" N Cl- NOTE; 5/8" GYP. BD. SECURE BOTTOM TRACK 3585T22 22 16' 17'-3' `�' ONE-HOUR WALL PER i- TO CLG. ABOVE S SE CONCRETE SLAB USING ca M cc UL #U465 POWER DRIVEN FASTENERS 358ST22 22 24' 15'-0" M • 0) IN. .145 AT 18 O.C. 358ST20 20 16" 18'-3' V Malin! - TTING ROOM /l p \ FINISH FLOOR \ ■M1 FINISH FLOOR l \ FINISH FLOOR 358ST20 20 24: 16'-0" NO O 6" 600ST25 25 16' 20'-0" EXISTING ONE—HOUR RATED WALL p N.T.S. MULL PARBION N.T.S. DEYLSN�G WAIL PAR?�TION N.T.S. O O 600ST25 25 24' 15'-0" Al 1 _ . tr, ,_, i , l- e s tM tM att J4 *Or" * . i lel 1! • 1 - illt iiii • ID [ I 6 ., • kmw 4 EXISTING GYP. BD. EXISTING DECK HT. IS DUSTING,A.C.T. CEILING NEW EMERGENCY LIGHT TO BE NEW SUSPENDED LCD N. EXISTING TRACK LIGHTING BOSE DS100SE SPEAKERS. EXISTING DECK HT. IS •• CLG. TO REMAIN APPROX. 0 30'-7 I/2_ A.F.F. 0 15-6 AF.F T INSTALLED ABOVE SLATWALL - PROVIDE CAT-5 CABLING TO TO REMAIN THROUGH OUT BIM. OF SPEAKER TO BE MID. APPROX. 0 30'-7 1/2" A.F.F. EXISTING RECEPTACLE ° G.C. TO VERIFY IN REMAIN - PAINT P_1 G.C. CAN REUSE EXISTING IF CASHWRAP. COORDINATE WITH SALES AREA - TYP. 0 12-8 A.F.F. MP.) G.C. TO VERIFY IN TO REMAIN EXISTING FIRE SPRINKLER IN PROPER WORKING ORDER HOT TOPIC REPRESENTATIVE EARS TO REMAIN - TYP. i "SPIDER TRACK" DISPLAY SYSTEM � ANODIZED SILVER FlNISH ,..,, _.. __ ._ _._..._._........__._..........,. :: _ :::::::a::r::i. _»__........._._._ I♦ '.... .: ;.I ... � :. .. ..:,....:::;:::: :: _......._,... .. � Y �6 XA E I ATTACHED TO STOREFRONT SOFFIT. .... :..; I , I p € �) EXISTING MONOPOINT LIGHT W", _.,.,_,.,,__. _ ._-' - ' 2 :NEWT CK HEADS ,... ... ° �• � FIXTURES TO REMAIN-TYP.k. j. ; DON CH SECTION s OF b(ISTING TRACK ;(Tl(P.) " NK - r,(E) ;-- - (E) 2. .CONDUff HIXIEASDn.S 7 EEMSAPWRI tYP. ►s: 3 WEIR PO C ,j 1 ..... c (E)~' ' c „ ( ) wp c ( oc (E me - :EEE: ►- 'f f HVAC NOTE; I�I. ,. i I � k �,; �. �g tv € €€ €€ (......_ EXISTING MDF BRICK VENEER I € € € €; € ' OFFlT TO paM G.C. TO RELOCATE THERMOSTAT TO STOCKROOM & PROVIDE REMOTE SENSOR IN--.-..-......... ... :: ' :::::::::::.::::: € € S REMAIN - - H I P� 0 € € 0 , ® € SALES AREA, CONFIRM REQUIREMENTS LOCATIONS ONSITE W OT TOP C .M.tit t EXISTING LIGHTING IN s € _:� ` jx : .. >k � _ I 0._ .,,,, - .. .a � ) ! EXISTING FIRE SPRINKLER II■ a STOCKROOM TO REMAIN 1 y µ,-' I w „ " ._ _ -s I € o "" _ 3 CJ(31I ` HEADS TO REMAIN - "HP. SPRINKLER NOTES: , 1 27 -0 %�$ £ POWER€ P€4LE �� ) : NO WORK TO BE DONE s EXIS LNG `��� r ``w ~' C ', ,-- C 3 € € EXISTING c 1. EXISTING SPRINKLER HEADS AND ONES TO REMAIN - U.N.O. �.-.-" " .,."" m.."" "."""m I, C . . F....:C, ...; VC € pC EXISTING ELEC EQUIP I I S 1 C " 1 ! I �- r p' ALES AREA �C I C� PATCH/ REP R AREA WHERE (E) 3_.. _.,....,.', (E (E) ,-- : -., (E) ROWNG GRILLE WAS REMOVED TO 2. CONTRACTOR TO PROVIDE RECESSED HEADS WITH BLACK CAPS AT STOREFRONT, ��� ( )_NEW TRACK H S t $ € t (E) MATCH EXISTING SOFFIT PRIOR FITTING ROOM, ALCOVE, AND RESTROOM LOCATIONS AS SHOWN IN DRAWINGS AND TO REMAIN (E) INSf1ND ON EACH SECT P4-,„ € € € € z - --T....7„.. a € €ti , TO PAINTING ' AS REQUIRED BY CODE. PROVIDE UPTURNED HEADS & EXTENSIONS IN OPEN TO W __ tti NO TRACK. --.° °, €s � € DECK LOCATIONS AS SHOWN OR REQUIRED. .... DSTIN e- ACT 'DUNG tr € _ _.,_ 0 15- 1�2 F.F a € y °. .:z �� ' :; - € € € € € 3. CONTRACTOR TO PROVIDE ALL NECESSARY MATERIAL AND EQUIPMENT TO RELOCATE ~ , TORS N - P NT f i € ' a € t € € t € € r ° € € I OR ALTER HEAD LOCATIONS AS SHOWN IN DRAWINGS AND AS REQUIRED BY CODE. i `....._........ ........... £ / / AC E (E) 'C € C ' E) (E) EXISTING BRICK ARCH 4. CONTRACTOR TO COORDINATE ALL SPRINKLER WORK WITH MALL MANAGEMENT AS EXISTING FIRE SPRINK �I' € € € E) _ REQUIRED PRIOR TO PROCEEDING. ,_"."""." ._..." i C (E) C (E) € ( ) € € C3� ►% TO REMAIN - PAINT® HEADS TO REMAIN - TYP. 9 i (E) I .......:. € X72 - ) _ _ , ,e `� x 5. CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL EXISTING SPRINKLER HEADS r ..:> 0 15TIN , 8 p -.% €€ WITHIN THE FIRST 3 DAYS ON-SITE AND REPLACE ANY THAT HAVE PAINT ON THEM. si ' : ? i � ,._.,",�,, ......,..W....... € \ . SHALL INCLUDE IN THEIR BID TO REPLACE A MINIMUM OF 5 HEADS - COORD. _, _._ EXISTING GYP. BD. w.. " _ €€ € € € € r t r I € # E I W f HOT TOPIC P.M. IF ADDITIONAL HEADS ARE REQUIRED TO BE REPLACED. CLG. & LIGHTING ,, i • 1 ! ,... g ;r C t t £ (E pC (E) (E) C . t ' . ) F EXISTING STOREFRONT TO REMAIN ;i. € ! ; _ fi E W..-W , .;� (E E 1 SI C E • S .1 �� 0 1 1 c . ttNr; �` LIGHTING NOTES: w, FAT NG. ROOM - ' '3 It' 1. FINAL LOCATIONS OF ALL TRACK LIGHTING & HEADS IN SALES AREA TO BE (E) �2IiEW TRACK HEADS EXISTING FIRE SPRINKLER !.. APPROVED BY HOT TOPIC PROJECT MANAGER. G.C. TO COORDINATE LOCATIONS WITH •• 3 1 DON EACH SECTION HEADS TO 1117, I. = E EXISTING FIR(_ SPRINKLER HEAD REMAIN TYP. FINAL STORE FIXTURE LAYOUT AS INSTRUCTED BY P.M. OF TRACK. (TYP.) , HEADS TO REMAIN TYP. r • ; 2. G.C. TO REMOVE EXISTING TRACK HEADS AND RESECURE EXISTING TRACK AS REVD. �. --.,, ,, ,._, . ,,,,.,,,,,___.„ XA , R A ' t t „., . , ,, , _ -�- • G.C. TO VERIFY EXISTING CIRCUITRY IN FIELD AND MAKE DETERMINATION ON BEST LOCATION T CONNECT NEW UGHTING AND ELECTRICAL LOADS. G.C. TO CONNECT TO ~ 4- "SPIDER TRACK" DISPLAY SYSTEM EXISTING &/OOR OPEN CIRCUITS BASED ON FIELD CONDITIONS._ _ _ xA4„,t„ 7 EXISTING GYP. BD. EXISTING ,14.C.T. CEIUNG EXISTING TRACK LIGHTING BOSE DS100SE SPEAKERS. EXISTING ,A.C.T. CEILING EXISTING LIGHTING TRACK TO NEW EMERGENCY LIGHT TO BE WITH ANODIZED SILVER FlNISH CLG. TO BE EXTENDED 0 15-6 A.F.F F 1 TO REMAIN THROUGH OUT BIM. OF SPEAKER TO BE MID. 0 15-6 AF.F T� REMAIN. G.C. TO REPLACE INSTALLED ABOVE SLATWALL - ATTACHED TO STOREFRONT SOFFIT. 4. G.C. TO CONNECT ALL NEW LIGHTING TO APPROPRIATE DISPLAY / LIGHTING TIMERS I REMAIN - PAINT _ SALES AREA - TYP. 0 12'-8" A.F.F. (TYP.) REMAIN - PAINT _1 HEADS AS SHOWN, TYP. G.C. CAN REUSE EXISTING IF " AND TIME CLOCK. IN PROPER WORKING ORDER 1 -0 6 ,_„__. _. ...»..., EXISTING MDF BRICK VENEER 5. G.C. TO BALANCE PANELS WITH NEW ELECTRICAL LOADS AS REQUIRED BY CODE. REFLECTED CEILING PLAN SOFFIT TO REMAIN - PAINT ,.........,. ,._ p.._....., ......_..:_»,."_.... �..... 6. ALL RECEPTACLES IN STOREFRONT SOFFIT TO BE BLACK W/ BLACK PLATE COVER. 1 7. G.C. TO VERIFY ALL EXIT AND EMERGENCY LIGHTING IS IN PROPER WORKING ORDER ' "'" 8CALE' 1/4' • I-Q' ON THE FIRST DAY OF CONSTRUCTION, REPORT ANY BROKEN LIGHT FIXTURES TO I HOT TOPIC P.M. WITHIN 24 HOURS SO THEY CAN ORDER REPLACEMENTS FROM " VENDOR. FAILURE TO CHECK OR REPORT BROKEN LIGHTING WILL RESULT IN G.C. I RESPONSIBLE FOR PAYING ALL EXPEDITED SHIPPING COSTS. OPEN TO DECK CEILING NOTES; -L.W „_ -I- REFLECTED CEIUNG PLAN NOTE; I 1. THE REFLECTED CEIUNG PLAN SHALL GOVERN ALL CEILING PENETRATION 1. ANY EXISTING DUCTWORK IS TO BE RESECURED AS REQUIRED AND IS TO BE ~M -~~ LOCATIONS. MECHANICAL DUCTWORK AND ALL ELECTRICAL CONDUITS SHALL BE CLEANED THOROUGHLY. ANY EXTERIOR INSULATION IS TO BE REMOVED. C\ L RUN TO AVOID CONFUCT WITH THE REFLECTED CEIUNG PLAN. - G.C. SHALL 2. G.C. TO REMOVE ALL ABANDONED OR UNUSED DUCTWORK, PIPING CONDUIT, "_" "" 2 -" ". mss" NOTIFY TENANT UPON THE START OF PROJECT IF EXISTING DUCTWORK, CONDUIT INSULATION, ETC. FROM THE SALES AREA, FITTING ROOMS & STOCKROOM. , OR OTHER EXISTING SYSTEMS WILL CONFUCT WITH THE PROPOSED REFLECTED 3. ALL NEW CONDUIT ETC. TO BE PLACED IN AN ORGANIZED MANNER RUNNING - W W 4P - CEIUNG PLAN. NO MODIFICATIONS TO THE REFLECTED CEIUNG PLAN WILL BE IN STRAIGHT UNESi OR 90 DEC. ANGLES. HOLD CONDUIT AS TIGHT AS POSSIBLE LA ' - ACCEPTED DUE TO INSTALLATION OF CONTRACTOR PROVIDED SYSTEMS OR TO UNDERSIDE OF EXISTING JOISTS. EXISTING ROOF STRUCTURE. EQUIPMENT. 4. G.C. TO RESECURE ALL EXISTING EQUIPMENT. i j VERIFY DETAILS IN FIELD EXISTING STRUCTURE ABOVE V.I.F. �' ID MK- / 5. EXISTING STRUCTURE TO BE CLEANED THOROUGHLY. G.C. TO PAINT "P-1" ALL i` r �---_ CHANNEL NUT I �� CONTRACTOR'S NOTES; SUPPORT BRACING,STRUCTURAL SSYSTEM do WALL (SURFACES ABOVE 12 5" A.F.F. ""1.2"" ""."".""" ..""" ; mac • . i .1. ' 0 4 x _ ♦ q„ „ .,, ,,.. Ll. �.. 1 c!) L!) „, ,,,,:: It -I.i , 1. ' ' r /• firr- _ : H<-BOSEDS1OOSES ~..of SPEAISER TO E ~~ ~.„....._ ABOVE 12�-5' MTD. 0 12-8 A.F.F. �IYP.) _ I 1 --4.17 O 1- 085B _- _I ©� =© $ — 1 .v OIFFlIT,,GPAINT�DF _Alill a \ �� Q �� 11l1 € , ..,,,,. . . N : ' Y'Y Nil: I_ X s.. m,...~_..~..„w _in o �� w in o Yi1 .. O,_ N . \ ,_ N 1 1si�f1 •1� .. .� T/Nrp+) ice �i'1 EXISTING BRICK '0. .... .. ... • • •� ARCHWAY, PAINT - LL In _.. _. _. _ _.. _... _ _ -_ -- _ __ ■�■ ..� VIII. qq / \ - ■■� ! N• \ \ \ \f I 11 4” " WOOD BASE OVER R © 4' HIGH BASE OVER II1 i Ac---0 raj gC 5" WOOD BACKING ~ SCRIBED TO FLOOR. AS SCRIBED TO FLOOR. CI SALES AREA ELEVATION 1 SALES AREA ELEVATION 1 , . SCALD 1/4' • f-0' I SCALD 1/4 • f-o' „._ _„_„__ ......_ .1 . mil I _ _ _ f __i_ ...._....._.„._, mi 1 __ ___ maw , 1 BOSE DS 1 00SE SPEAKER. BIM. OF SPEAISER TO E MTD. 0 12'-8 A.F.F. .) ... .._, \ 0 TO DECK ABOVE EXISTING BRICK - - - • ARCHWAY, PAINT �" ', EXISTING BRICK v � µ �. P-5 k . I L P 5 ABOVE 121-5" _ ABOVE 12-5 \ O ARCHWAY PAINT i i \--\ _. .._...,.___ Q IMPIP"-- 111111=1 ek1=11111.111110■■ rhilli....1111111MMIL to >7 ��h�,�� �� ,� k� ,pa" EXISTING BRIO MDF ;�mot ���� ���©' �r m ~ _ ...._......... I - a EXISTING BRICK SOLDIER EXISTING BRICK SOLDIER SOFFIT, PAINT _ ii..1 ¢ ~~~ II : C0uRsElbO ` �f � COURSE, PAINT _ .�; \• .4Id Z N — / \ ■ ill t p 3 a _� 1 ._ _ : E I 1 OPEN I I o _ ¢.._.... ...• E- Y z�_ - lb ill we : :>EXISTING BRK LDIER ■ EXITING BCK LDIER B \I : E, P ARCHWAY 1� `" _.~/in 0 N — _ EXISTING STOREFRONT ! ," („1„J� w X ■ GLAZING SYSTEM kW 2 �' r — _� k\ mM ■ - ?�� m; OPEN N .■ \ 0 • EXISTING STOREFRONT ON TEMP.ALUM. OR NT NEW FRAME WI DOORS NEW DOOR PULLS TEMP. FRAME 4" " HIGH BASE R 1+1��I 4" " WOOD BACKING ISIa GC TO PAINT DOOR .._......~Me. ~!._......... BY G.C. © vow SCRIBED TO FLOOR. SCRIBED TO FLOOR. © © PAINT NEW ADA SIGNAGE, �,,.. .. SEE DTL 6/A3A O ~ - Q SALES AREA ELEVATION SALES AREA ELEVATION ._�..~ a . 3 4 • f- 4 us • f-0' 1 A ...±.... IL.ENI ? coi ® \ \ w qd DOOR-MOUNTED SIGNAGE .. ~. .� ..~w.~.. ...._ N _. IT-\ IN \ N APPROPRIATE TO ROOM USE. 1 � 9H / c ., \ WOMEN MEN \ cn .‘ -_71., 8" 8" la \ § g 3 —4— F--____\ 3 so 6 _ _ _ - = o g \ \ \ E5 0 Q - - 1 (I) STRIKE SIDE 13 N ELJ O • 9 O .,...,, .. , CD Cl. O O O -I W\ CO J - o - ON DOORWAYS LEADING TO "' a.c - LLJ '6- ~ � MEN WOMEN RESTROOM S�Y4iB0�LS TO�EPf�OwDED ARE ^�;-- •••• :.•.:.::.:::: 12 EQUILATERAL TRIANGLE .a •4 1 u� \ \ C�RCLEEFbR WOMEND 1/4 ... N _..__ ......._... CC THAI( CENTERED OP DOOR \ Q \ \ - \ \ RAISED BRAILE LETTERS C6OLOR WITHFD FLOOR, CONTRASTING CONTRACTOR'S NOTES; N 1. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. -4 Ch w p� I PANE . .D4 i QI SALE DRAWL • CONTRACTORS MUST VISIT JOB SITE TO .J SEE ICAL SH�S VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING N 'Q ADA DOOR SIGNAGE BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY O Cl) SALES AREA ELEVATION INTERFERE WITH THE PROPER D ELUTION OF, TO TENANT REPRESENTATIVE REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF GOALS 1J4' • f-or COMPLIANCE CO DITIONS AFTER COMMENCEMENT NOT OAF FOR JOB CODE u� - f-or � A 3 FINISH SCHEDULE HOT TOPIC'S VENDORS RE8PONSIBILflY SCHEDULE RESPONSIBILITY SCHEDULE I 1 ty ..,,».._ 111�cJ ,..,.. 1 UGIif1NG SLATWALL METAL FIXTURES ITEM FURNISHED INSTALLED EXIST. REMARKS ITEM FURNISHED INSTALLED EXIST. REMARKS AMC ANO GULASARIAN ATTN: TERRY SEXTON ATTN: BLAIR BUCHANAN RESPONSIBILITY SCHEDULE IS RESPONSIBILITY SCHEDULE IS _. ,-._. � ?1.._..._.... MS; LA-SHEEN EGGSHELL LATEX MST UGRIC SPACEWALL LAUREL MANUFACTURING z GENERAL IN NATURE AND DOES NOT z GENERAL IN NATURE AND DOES NOT 4•11%, ► F v" . DOORS MD TER SEMI-GLOSS ALKYD PHONE.{323) 957-6012 PHOf 4714) 961-1300 PHONE:(856)-461-660 x306 0 o w w 2 e b ° REFLECT EVERY COMPONENT OR o o REFLECT EVERY COMPONENT OR �► �_=ilk FLAT LAID( FAX:(323) 462-2108 FAX:(714) 961-0976 FAX:((85 ) 461-6622 °It cg °i RESPONSIBILITY. U.O.N. °� �° RESPONSIBILITY. U.O.N. !Q � L LOS ALL Kip agulasarianOmidwestlighting.com tsextonOspacewallwest.com blair.bOlaurelmfg.com c RESPONSIBILITY IS G.C. FURNISHED o o J RESPO IBIUTY IS G.C. FURNISHED i " ,,,,�, z AND INSTALLED. AND INSTALLED. , INSTALLATION: GYPSUM BOARD TO RECEIVE LATEX PAINT TO BE PRIMED WITH (1) COAT OF VINYL PLASTIC SENSORMATIC T-1 TERMINATIONS STOREFRONT DOORS k c) I-' c1 i E g 1=' 8 I-`' c., °z °vs I� SEALER PRIOR TO RECEMNG (2) COATS OF PAINT. WOOD TRIM AND SLATWALL TO RECEIVE OR ATTN: MIKE UPTON ATTN: KURTIS SISCO ATTN: SHANE BRUSCOE "` _ .•.., - ` - ENAMEL PAINT TO BE PRIMED / ONE COAT OF ENAMEL UNDERCOATER PRIOR TO RECEMNG 2 COATS 1O INTERNAIONAL ( DESCO , i Li 3;; •.,i _ _ _ _ _ ; " ''► OF PAINT. PAINT ALL WIRES, RETURN AIR GRILLE, & SUPPLY AIR GRILLE TO MATCH ADJACENT CEIUNG AREAS 949 770-1880 PHONE (949)-861-2830 x228 PHONE: 860 870-7070 - a ' ( ) ( LCD SIGN & BRACKET • • NEUTRAL PIERS ■i �■■■min VERIFY DETAILS WITH LANDLORD / •..._..: b ;."....,.. FAX:(9 9 454-8105 FAX: FAX:(860 70-1074 mu ton coint.com ksiscoOworidlinkinte ration.com sbrusco esco ro.com N.,^7 `r 1�••�4 /�•• r 1.4 rir A?7,..r. �������� „w,_,.W,,,..._. P g p PROJECTION & BRACKETS • • �s'•�r �Ri'R *�� /��/►^' ►^� ► A<^T �` ,,,-..... ..._......._..... .............�..........,. P-1 BENJAMIN MOORE f HC-69 "WHITALL BROWN" - FIAT LATEX PLEXI HARDWARE BARRICADE GRAPHICS ANCHOR SIGNS COMPANY REAR DOOR SIGNAGE • • REPLACE AS REQUIRED STOREFRONT FRAMING SEE SHEET A5 ...._... ATTN: JOHN STEGER ATTN: RICHARD DE LA ROSA ATTN: JOSH MUCKLEVANEY P-2 BENJAMIN MOORE #2134-10 "NIGHT HORIZON" OR GROUP - THE �Y ANCHOR � ��� VINYL WINDOW GRAPHICS • • PR. ENTRY DOORS/HARDWAR: a`d „ SHEENS: PHON F4800) 418-8899 PHONE.(323)-551-6586 PHONE:(843)-576-3275 CEILINGS: FLAT LATEX FAX:(817) 453-9139 FAX:(323) 256-8600 FAX: (843) 747-5907 BARRICADE GRAPHICS • • BRICK PAINT SEE SHEET A5 FOR APPLICATION PROCESS johnOkastongroup.com richard.delarosaOthegarveygroup.co Mucklevaney®anchorsign.com CODE-RELATED SIGNAGE 4 7 "-""-" "..'v 1^� •r W^W III -_._gt s.Ira• • PER INSPECTORS REQUIREMENTS T � '�''S / ���` ,������������� ���������������� P-3 BENJAMIN MOORE - READY MIX "WHITE DOVE" SEMI-GLOSS. AT ANY DOOR • /r��..-'1.�....�. AL AL . AAA A. 11 AAA .. . AL A. A A. -� BRICK VENEER SIGN PERMIT & APPL • • WHEN REQUIRED 7♦r`rithr ∎�������� /1r ■ 1�l' 70'►�/�1r r�•�� �* P-4 BENJAMIN MOORE 2022-30 "BRIGHT YELLOW" P42-84; P42-3B ATTN: GEORGE DE LOS SANTOS �r�L��.4∎■ ■ ■ ■ ■ .. 1/�..����1/�.6.4..I/A. . .4.`1 .��14∎AAL A. . . . . . . . SUPER SPEC HP WATERBORNE POLYAMIDE EPDXY HIGH ARID BRICK ••EI•■CI■■ STOREFRONT SIGN • • GLASS TRANSOM .. � � %-" PAINT: "BEHR" - CUSTOM WHITE: BASE 2050, INT. EGGSHELL ENML/EGGSHELL, LOW PHONE:(310) 768-8500 .. �► .. �' 1 P-5 I FAX: TOILET ROOM L T C L T C N S /���,?;;1�►�>t?�A��. ����.����' ^�����, ^,��������`��� �+1� y,1,�������������� ; yl:►ITItoll �•• �"i∎ 4 ∎ ∎r►∎ ∎ ∎ .► � � ... ∎ .► ∎ L .. ∎ .► ∎ AL .. A � 1. AL*∎•∎ ∎ ∎ ∎ ∎ ∎ ∎ ∎ ∎ � �., a .""," ;/Y�t':i .■•.i George0artobrick.com �� �� .. � ��►� �� �•.� � ∎`1, Vir 1 1f;.111INi. EllKI WATER CLOSET & LAV. • / ry �,yt��♦������� ►^�/� ♦��^���-���♦�♦�♦�♦�♦�♦�♦�♦�♦�♦�♦�♦�♦�♦� _.......�, STAIN: "BEHR" - LODEN ISTC-22, SEMI-TRANSPARENT CONCRETE STAIN PER HT DIRECTIVE. MOP SINK • ∎41.7. �..'A,����������►���/�^�/��������`�/������T�t�T���*�''7����'������������� " • SEE SHEET A5 FOR PAINT/ STAIN APPLICATION PROCESS DOOR SCHEDULE ``∎∎ ∎4∎�A&i•A•A • ■ .4. ���l& Al�4/∎A•.0. .4.4;141 .4. A.414:-.4.44:40.. .. .*' •.15*** *** DRINKING FOUNTAIN • �:��5�=�t!►�'Rt�t�������/ ����1�•���NI rs' M707������������������������ w..,._."... 1 V�r1�V.414.4 4•. . .. L A...�.1►�.CA��11�.►.•��.5�6.♦.♦. .•&•. •&•. KEY O.''.'PION T.P. & TOWEL DISPENSER • 3 mz..�y-7_, 7∎r: I ;�/��1 r∎r��go�/�`:�1►t3/~.���=������������������������ ^Wry ADM \- .I �I-.��I \r - NPA�A��V�� A���_�■.._'►_�.._..�1►..._ ..._1►_...∎w_∎I._w_.i∎._�_..�._._._._._.i� I y� "...,,, ., i... El GRAB BARS • • • ��►.� ; ,.H•i .� "." , . .." -__ CS-1 LM. SCOFIELD CO. UTHOCHROME CONCRETE STAIN "CS1". COLOR: BLACK IN SALES AREA, ALCOVE, " " " FLOOR CORING/CgNC. AND FITTING ROOM FLOORS. BY G.C. - CLEAR SEALER TO BE MATTE FINISH. 2 CUSTOM 31-0" X 9 -0 ALUM. FRAME W/ 1/r TEMP. GLASS INSERTS & TRANSOM ABOVE MIRROR(S) • INFILL/PATCH D(T'G. • •• G.C. TO COORD. W/ OWNERS VENDOR LD VERIFY EXISTING OPENING WIDTH. `� -._...._. ... .._.. ._ CS-2 SURTECH ICS-672 WITH #575 CONCRETE SEALER APPUCATION HARDWARE MARUTE PANELS/J-MOLDING • CONCRETE SEALER • • MATTE FINISH - STOCK / HALL ' AREA APP ED: STOCKROOM AND HALLWAY G.C. TO SUBMIT HARDWARE TO HOT TOPIC P.M. FOR REVIEW & APPROVAL PRIOR TO PURCHASE. BACKING FOR ALL ITEMS NOTE: INSTALL & MAINTAIN PER MANUFACTURER'S RECOMMENDATIONS • SHT. VINYL 0 TOILET R . • • : ■ PLEASE NOTE THAT SOLVENT BASED SEALER'S ME NOT ALLOWED SPINE: LISTED ABOVE AS RED. PROVIDE - SIGN ABOVE DOOR IN 1" HIGH LETTERS ON A CONTRASTING BACKGROUND STATING "THIS DOOR TRASH CAN • FLOOR TRANSITIONS • • • VF-1 ARMSTRONG CONNECTION, TILE VINYL FLOORING, CORLON #88724 "PORCELAIN" TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" WHEN REQUIRED BY CODE HEAT W HEAT WELDED SEAMS & 6 COVED SELF BASE SOAP DISPENSER • RUBBER BASE • • MFGR'S RECCOMENDED ADHESIVE. A ALUM • • , E iNIS. To MA CH EXISTING STOREFRONT BASE VINYL BASE • • NON-PUBLIC AREAS ONLY _�,, ,,,,,,,,-. :.,.t1 , rt'.'it' '.Ihl•ia.i..'11 ,,4.n•.p, : •.• g�� T� Z © ❑NEW 0 EXISTING - PROVIDE AS NOTED BELOW IF EXISTING IS UNSUITABLE. LT C LT C NS MALL FLOORING O STRFROM • • WERE ��H_I DO WrmO N I - DOOR SALES FLOOR FLOORING • • B-1 4" HIGH WOOD BASE PAINTED P-1 3'-0" x 7'-0" x 1-3/4" SOLID CORE WOOD DOOR. PAINT PER INTERIOR ELEVATIONS " AREA APPLIED: ITEM BASE THROUGHOUT STORE WOOD BASE • • REPRESENTATIVE: FP - . NOTE: INSTALL & MAINTAIN PER MANUFACTURER'S RECOMMENDATIONS 3-0 X 7'-0" TIMELY 'C' SERIES K/D 18 GA. STEEL DRYWALL FRAME EMBOSSED FOR 1-1/2 PR. BUTTS. IMO LT C LT C NS __"" _ COLOR: FACTORY FINISHED BLACK. NOTE: FRAME USES PRE-THREADED SCREWS. DOOR USED WOOD SCREWS. - G.C. TO PROVIDE AS NEEDED. DEMISING PART. STUDS • • • ......_...-.._.."... . - '... ._ B-2 JOHNSONITE # 40, BLACK, 4" RUBBER COVED BASE - N STOCI(ROOY / HALLWAY ONLY WM,. " " DEMISING PART. DRYWALL • • • PATCH, REPAIR, & REPLACE AS REQUIRED LOCKS PAIR PTBRC—RP 4 x 4 BLACK (3/BOX) 345 NEW W FRAMING/ FALCON/18101x626 LEVER TYPE PASSAGE SET INSTALLED 30-44" A.F.F. SILVER W/ SILVER STRIKE. g�p��I C • B . • • CLOSER: TOILET R 1� FRAMING/ • • g�� •N gp BF-1 "ARTO BRICK" 2 1/2" X 8" "TAN DISTRESSED BRICK" BRICK VENEER TILES DORMA 7601 TOP JAMB MOUNT FIJ�t18NGG NO • ARTO BRICK - (3 01 768-8500. " NOTES: COLUMNS AT DEMISE • • GROUT: POLYBLEND 110 ANTIQUE WHITE SANDED GROUT - G.C. TO PURCHASE AT HOME DEPOT. • PROVIDE DOOR BUMPER "QUALITY" NO. 302. (VERIFY W/ PLAN WHEN DOOR SWINGS TO WALL) INTERIOR COLUMN FURRING • • w..-•...•. £ .".._ STAIN: "BEHR" - LO ISTC-22, SEMI-TRANSPARENT CONCRETE STAIN PER HT DIRECTIVE. • PROVIDE 12" x 32' STAINLESS STEEL KICK PLATE. SEE INTERIOR ELEVATIONS 5 BLOCKING FOR DOORS I • • _-__.... _...._._. DOSi1NG San i>b011 TO D05iNG RE'SITRDOY DOOi� © WALL PREP. AND PAINT • • WD1 WOOD CASING - 1"x6" QUALITY GRADE CASING AT SPECIFIED LOCATIONS. PAINT "P-2" ❑NEW ® EXISTING - PROVIDE AS NOTED BELOW IF EXISTING IS UNSUITABLE. "4—""' CORNER GUARDS • • G.C. TO CUT DOWN IN FIELD AS NEEDED 1 CG1 CORNER GUARDS - 1"x1"x12'-0" HIGH BLACK METAL CORNERGUARD (#110165-023 FLAT BLACK) 3-0 Sx 7'-0" x 1 3/4" SOLID CORE, PAINT GRADE WOOD DOOR. � L T C L T C N S MANUFACTURER: STYLMARK, INC. (800) 328-2495 . STAIN FINISH 626 } G.C. TO MODIFY IN FIELD AS NEEDED PER APPLICATION 3'-0 X 7'-0" TIMELY 'C' SERIES K/D 18 GA. STEEL DRYWALL FRAME EMBOSSED FOR 1-1/2 PR. BUTTS. GYP. BD. CEIUNGS • • PATCH & REPAIR AS REQUIRED WC1 FRP WAINSCOT - MARUTE - COLOR: P-100 WHITE COLOR: FACTORY 'NAVAJO WHITE' PAIN IPOSED DECK 1 1-1/2 PAIR PB-RC-RP 4" x 4" SATIN CHROME (3/BOX) 345 SEE PLAN SHEETS FOR ANY MEP WORK AT PUOLIC AREAS REP OF EXPOSED SMALL LOCKS / LATCHES: ALL MEP WORK TO BE BY CONTRACTOR U.N.O. DECK READY TO PAINT • • mum=- . FALCON LEVER TYPE PRIVACY SET. SATIN CHROME W/ CHROME STRIKE. SUSPENDED ACT CEIUNG • • PROVIDE NEW TO MATCH EXISTING SW-1 "SPACEWALL" OSB PANEL W/ METAL REINFORCED SLATS 0 2 2/3" O.C. - STAINED BY ".."...-.--.....".�"...................-- ..""".. MANUFACTURER (SPACEWALLS SEE DETAILS ON SHEET A8 INTERNATIONAL SYMBOL OF ACCESSIBILITY AS REQUIRED BY CODE 1 SW-2 "SPACE WALL" PAINT GRADE MDF PANEL SLATWAIl W/ METAL REINFORCED SLATS 0 6" 0.C. NORTON T C L T C N S / NORTON NO 1603 ALUMINUM DOOR CLOSURE. W/ 90' HOLD OPEN � LEAVE UNPAINTED - SEE DETAILS ON SHEET AS NG ROOM DOOR/FRAME STOCKW • DE DOOR BUMPER "QUALITY" NO. 302. (VERIFY W/ PLAN WHEN DOOR SWINGS TO WALL) M DOOR • • REPLACE AS REQUIRED IMMUNE SALES AREA TO EXISi1NG FRIMIG ROOM Dl - •i i iii.R • N 0 ❑ NEW ® EXISTING - PROVIDE AS NOTED BELOW IF EXISTING IS UNSUITABLE. FRAME/HARDWARE / • • REPLACE AS REQUIRED <M-1 CHEMETAL � 719 - SATIN SILVER ALUMINUM } FIRE RATINGS: FIXTURE CONTRACTOR TO SUPPLY DPP REAR DOOR AND FRAME • • • REPLACE AS REQUIRED d AREA APPUED: FIXTURE FINISH SLAIWALL 3-0 x 5'-0" x 1 3/4' SOUD CORE PAINT GRADE WOOD FITTING ROOM DOOR. THIS DOOR IS PROVIDED REAR DOOR PANIC BAR/ �._.. - REPRESENTATIVE: (800) 807-7341 WWW.CHEMATALCO.COM WITH THE FRAME TRIM KIT BY G.C. 7 •pIN �1 • •• •• REPLACE PER HARDWARE SCHEDULE AS REQUIRED w LU _.._ "_-"- NOTE: INSTALL & MAINTAIN PER MANUFACTURER'S RECOMMENDATIONS FRAME: KEY ALr laDRS ALIKE w`. , TIMELY CLASSIC C-SERIES METAL FRAME IN BLACK FINISH TURN V • • • "' w I/MGES: ACCESS pS REQ'D 11 4 1/2" X 4 1/2" BLACK BOMMER SINGLE ACTIN SPRING HINGE WITH 2 HINGE STOPS - TOP FOR OT� IAV/ETC. • •• AS REQUIRED - - --. & BOTTOM LLB 4311C/450BP-601 OR APPROVED EQUAL i ta.4 i 1.--- LOCKS LATCHES F.C.I.C. "`m INSTATED 30-44 A.F.F.- CYLINDRICAL LEVER SET W/ FRTMIG ti00Y LT C LT C NS 1 CAL ROYAL STOREROOM LOCKSET N BRUSHED CHROME i$L05 BENCH • PAINT P-1 _..... !. -.,..._.....,�`. INTERIOR PRIVACY SET. KEYED OUTSIDE. C)1•PROVIDE CLOTHES HOOK ON INSIDE 0 48' A.F.F. - AMEROCK H55451 HOOKS • • SPEC: AMEROCK H55451 w ....._._...... 1 NOTE: (8) EXTRA KEYS TO BE FURNISHED FOR OWNER. < 41 g� J " 4. R W IgiEUGGESICKS © 1 CAULKS/SILICONES/ • • AS REQUIRED __ ._ A .. NOTE n o n ARE DUSTING. REPLACE DAMAGED OR MISSING LID'S A S SHOWN HERE. SALES A R E A & FIXTURES LT C L T C NS <1 AC-1 ` 36" GRAB BAR PROVIDE SOLID BLOCKING IN WALL REAR BAR TO EXTEND 12" FREESTANDING FLOOR • • .._..._ir• ___: s 1.BEYOND THE CENTER OF THE WATER CLOSET TOWARD THE SIDE WALL AND AT LEAST L T C L T C N S FIXTURES • COI 24" TOWARD THE OPEN SIDE OF THE WATER CLOSET AND MOUNTED NOT MORE PICK-UP PERMIT/ CASH WRAP/ COUNTERS • • G.C. TO ASSEMBLE AS REQUIRED THAN 9 BEHIND THE WATER CLOSET SEAT. #8-490, 36 LONG, SURFACE MOUNTED. PAY PERMIT FEES • • WALL & DISPLAY FIXTURES • • gall" " CONSTRUCTION SITE • • PROVIDE INFORMATION TO HT AND I I AC-2 42 GRAB BAR - PROVIDE SOUD BACKING IN WALL BOBRICK 1B-490, 42 LONG, PHONE AND FAX ARCHITECT. MISC. SALES WOOD TRIM • • G.C. TO ASSEMBLE AS REQUIRED SURFACE MOUNTED. 0 BEa- Q� CONSTRUCTION SITE PROVIDE WEEKLY E-MAIL PHOTO'S. • TOILET PAPER DISPENSER - CENTERED Al 19" A.F.F. MIN. BOBRICK 6-685, ❑ NEW ❑NOT USED ® EXISTING - PROVIDE AS NOTED BELOW IF EXISTING IS UNSUITABLE. DIGITAL CAMERA • • TO HOT TOPIC SLATWALL • • 1 O AC-4 OBTAIN 0j0 APPROVALS SURFACE MOUNTED. DpOI IN WRITI A.W.A. • LOOSE HARDWARE AND g 3-0 x 7-0 METAL DOOR AND FRAME. • • G.C. TO CLEAN AND INSTALL ; 1- • SPRINK SYS. PLANS/ CHANG ORDERS NOT PROCESSED WITHOUT SH x LOCKS / LATCHES: PLANS/ PERMIT/ FEES • • A.W.A. 'S. RECEIVING •G�HApRDW[ApRRE 6 1 Q At WALL MOUNTED 18"x36" MIRROR - WITH BOTTOM AT +40" A.F.F. NEW DUD( V4OXEB PANIC / ALARM HARDWARE W/ 7-PIN MORTICE CYLINDER & SATIN CHROME STRIKE. � C DISPOSE 0 • • R u V (ALWAYS PROVIDE THIS UNLESS SUITABLE EXISTS) MODIFY SPRINKLER SYS. • • VERIFY MALLS REQUIRED CONTRACTOR • • OFFLOAD FROM TRUCK ° AMERICAN DRYER f SP1-T WHITE POLYCARBONATE AUTOMATIC ELECTRIC MALL D�E�PEOSyI�(T� FlXTU WRAPPINGS 1 g AC-7 HAND DRYER. G.C. TO INSTALL PER MANUFACTURER'S INSTRUCTIONS. �4WE L�ALL SIDE WITH TENANT'S NAME AND SPACE NO. PER LANDLORD'S REQUIREMENTS JAN �RiAL SIEItVECE • i, LAY - ° ° g I ll- CLOSER: TWO CLEANINGS: FIRST AT PUNCHUST, Ass. _ _ - - _ A 8 1 U AC-8 WALL MOUNTED WATER HEATER BELOW LAVATORY NORTON #1603 SINGLE DOOR KEEPER OR EQ. FINAL CLEANING / • SECOND CLEANING DAY PRIOR TO OPENING. CASHWRAP METAL STRAPPING •• •• T LU TRASH REMOVAL// © 15 f I CI- VES 7698 190 deg. DOOR VIEWER. DUMPSER RENTh.. • 7 it' ;;,i r N S E I AC-9 SIGN WITH RAISED BRAILLE LETTERS - MOUNTED AT +60 A.F.F. ROOF PENETRATIONS • • VERIFY MALL'S REQUIRED CONTRACTOR - - - - - - - - ,- - - - - , - - �.+, CO *TENANT'S G.C. SHALL MAINTAIN TIGHT FITTING SMOKE AND DRAFT CONTROL ASSEMBLY HAVING A FIRE DEMOLITION PERMIT AND 416 Ali`41►AI►�ii►iii►����I■ AMC 414 .∎ �A 5.OW∎/���������������∎. J■ AC-10 PLASTIC TRIM Al +48" AT MARLITE WAINSCOT. RATING OF NOT LESS THAN 90 MIN. WHEN ILSILD. INSTALL GASKET MATERIAL AS TO PROVIDE A SEAL FEES AS REWIRED?SI � J i�=m*bir•M a :',Mr l�'wir N ============�=�=� Q WHERE THE DOOR MEETS THE STOP ON ALL SIDES. OBTAIN INSPECTNNS • CC PROVIDE STATUS REPORT 7' it ►♦� ♦ ►�♦1►♦'►♦♦1►�► ►� ♦♦♦♦♦♦♦♦♦♦♦♦■ ♦♦♦ ■PAINT MALL SIDE OF DOOR AND FRAME TO MATCH ADJCENT MALL'S FINISH OR AS DIRECTED BY THE _ ,i'� Snit i'!i*;1 i�1►A� A. .0∎��A„i.1I Al( .�������������������������������1 " PROVIDE IT BUILT COPY � � � ymo � -. -. . � � � � • �'. yi1.:'� . . 1r ∎ IIV' ∎ `VV' NI ∎ IIV' ∎ 1r � � c:7 I— MALL'S ON-SITE REPRESENTITM� WHEN THE SPACE IS OCCUPIED. OF JOB SITE PLANS. • q!. ;*:/,� •♦♦ ►�►♦�v♦ s'♦1/♦ �'♦'/♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ` •� ABBRE1A11ONS RECEIVE/ UNLOAD ALL �►�L:.�►...���r��.►�►����-1....►�1��:►�� 1.J:►�.►� � ������ _ R. _. TT pppp��QQ • - - t-7.1t-To- �� - r1"R" r1 � '• / �V. '• ∎ ∎ ���� � � � � S O tACT6R �rAs�i�������� ■ . ilk I►��, ..�/�A���=�./Ah. ∎A.������Ak��. ''& Al.Al∎ A. I N 0 DOOR NOTES • PROVIDE TO OWNER AT TURNOVER rr♦ ■ ■ s AND WARRANTIES • ��..�j�,�'T.r��,}��� ��'��►���'�4 �`�4'�'/ � ��������� .- N c� r FURNISHED BY TENANT, INSTALLED BY CONTRACTOR - (F.T.I.C.) `►�rr�'jl►■ �`►�rl►■'IM■.■.�1-..���:.■ ■.-►���■1��.���..�.A5�.�.�.�.�.�.■.�.�.■.■.■. • EXIT DOORS SHALL BE OPENABLE FROM WITHIN WITHOUT THE USE OF ANY SPECIAL KNOWLEDGE OR EFFORT TEMPORARY BARRICADE • • COORDINATE WITH LANDLORD AND MALL -� -rl- ' •1.041� 1 c�� �► .∎Pte' `►�' WHEN THE SPACE IS OCCUPIED. 0'ai .•.41. w.�����..►��∎• /0∎∎w' wii��L^M&A�I. IL 46 �������I.■ A∎ ■ ■A∎A∎ ■I∎ G.C. PROJECT MGR. • � U FURNISHED BY CONTRACTOR, INSTALLED BY CONTRACTOR - (F.C.I.C.) o MAXIMUM PULL FORCES FOR INTERIOR AND EXTERIOR DOOR SHALL NOT EXCEED: 5 LBS. FOR INTERIOR DOORS 8UVRINO TENANT • AS REQUIRED: MINIMUM (1) AT FIELD N 5 LBS. FOR EXTERIOR DOORS / 15LBS. FORCE FOR FIRE RATED DOORS TURNOVER REQUIREMENTS • REPORT. !G.C. NOTE 0 Q CC • HARDWARE MOUNTING KIT FOR HOT TOPIC COORD. CLOSELY WITH TENANTS VENDOR G.C. TO REVD/ BILL OF LADING UPON RECEIPT OF ALL SHIPMENTS. ANY DAYAIGES OR FURNISHED BY LANDLORD, INSTALLED BY CONTRACTOR - (F.LI.C.) • LEVER HANDLED HARDWARE NOT REQUIRED TIGHT GRASPING, ETC. NOT EXCEED: 5 LBS FOR INTERIOR DOORS AUDIO SYSTEM • •• I g QN CQPL SHORT ES ARE TO BE NIDICATED AT RECEIPT, OR WITHIN 24 HOURS. FAILURE TO DO SO 5 LBS. FOR EXTERIOR DOORS / 15LBS. FORCE FOR FIRE RATED DOORS CONDUITS & PULL STRING ET TO PROVIDE 1 2 CONDUIT W PULL POWER FOR AUDIO SYS. • • gg I TS��H (� (�p�4T1�N• WILL REQUIRE G.C. TO CONTACT VENDORS LISTED ABOVE AM PURCHASE SAS ITEMS AT A4A FURNISHED BY LANDLORD, INSTALLED BY LANDLORD - (F.L.I.L) • ROOM IDENTIFICATION SIGNAGE WHEN PROVIDED SHALL COMPLY WI LOCAL AUTHORITY P.O.S. SYS. ( DATA AN G PIJJI,I B IASTALUAG G.C. OUST• • BOTTOM 10" AT ALL DOORS EXCEPT AUTOMATIC DOORS SHALL HAVE AN UN-INTERUPTED SURFACE. TELEPHONE EOUIPTMENf • • _ SHELVING AT CASHWRAP. ' A KEYED NOTES _. _.._. NOTES (N) -14,4„0 .. . �Ni f �LEASE LINE �' i .. .� s, !! EXISTING MALL BULKHEAD t tj N2 LIGHTING NOTES (L) `' `�` �,4 Lt NOT USED 'i .k u ... ., _.....,_.... CONSTRUCTION NOTES (C) filv ... ............. �E C1 NEW PAIR CUSTOM TEMP. GLASS STOREFRONT DOORS & FRAME, X • item _ TO MATCH EXISTING STOREFRONT SYSTEM FINISHES - SUPPLIED — ii ® & INSTALLED BY G.C. I g NEW GLASS TRANSOM W/ FRAME BY G.C. r C3 NEW DOOR PULLS - SUPPLIED & INSTALLED BY G.C. °.__.�. �' .......__. . IJ C4 EXISTING STOREFRONT SYSTEM TO REMAIN k _.--. C5 EXISTING BRICK VENEER TO REM p-g 3 REMAIN - PAINT w \ C6 EXISTING ARCHED SOFFIT TO REMAIN - PAINT 0 . r. £ 0 G.C. TO INFILL AREA AT ROLLING GRILL TO MATCH EXISTING '^ C7 ARCHED SOFFIT PRIOR TO PAINTING _.` '. .__........ II ii'''' } ----1- I I I .4 , 1 p 0 Ti V .4° X ti m \ Ea - w.� . - * ... I_____ _IL „__ __ ___ Co \ EJ ..4,44.4_ ........ _ r L I 1 4 __J 1--L. Li, ____I___ , , I :, i __, . _ . Z i F.: _ 7 -c< , [ w Ni. _ 11 .6=1117,, _r„,_4,:_II _ ro ..L_ I , -.4_ u: - ____ AI I L // r U 1 E N I IT --I I I I I I < c„,. d- E cn [ CC • LLII _r 1•4 •` , w\o N ..._.....M CV o c0 a.. a .�' .CO b) r [ ___ 0_.__ 3 ...._ rri „.._ \ ._____, LT. C Q COI 33 1 Co L C w,, _„ ____. _____I__ ® L 0 , 1 1 Cn I C o 4Z - . w® A I CD 1._ mC —II II \ \ II .\ \ N CONTRACTOR'S NO TE. ce• - M LL_ WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. .• Cr nQ MT DRAWINGS. CONTRACTORS MUST VISIT JOB SITE TO bo e ` Q VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITONS WHICH MAY 8°) INTERFERE WITH THE PROPER EXECUTION OF, TO TENANT REPRESENTATIVE. a = I Cl) STOREFRONT ENTRY SECTION AT DOOR REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START CI OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. MAX I s . %Ili.; ' 70 1 T, ._.... ` 0 - ..1—.-■ I-1. ... 7 iii....', 4_,.Ir. 1 :d , J. Ailp !!ikt 0 .Y to a �). _. ,e` ' , . gin.......... —1 1— \ Nt 114. "— --C ------I EXISTING BRICK O '1, 41a ARCHWAY, PA INSTALL NEW SLATWALL INSTALL NEW SLATW ON EXISTING SLATWALL, � . ON EXISTING SLATWALL NEW ALUM. FRAME W/ NEW TEMP. GLASS DOORS NEW ALUM. FRAME W/ = ..,rok ���, TEMP. GLASS STOREFRONT & ALUM. FRAME WITH TEMP. GLASS STOREFRONT I _ • __._.... �._ SYSTEM BY G.C. TRANSOM BY G.C. SYSTEM BY G.C. 7-EXISTING MDF BRICK � . . .. • �...._.... ....__........_.._._ _.....� '._._. SOFFIT, PAINT P_1 00 . —J 1 _ d c I . .,.... : -„,, MANNEQUINTYP.) . I I o MANNEQUINYP.) A? I \ N s :::::i2 "i ISG BIC STOONT ENG STONT CAY, AI TO REMAIN E E S -° m°° , 1 WALL, PAINT C) LEASE UNE\ EXISTING BRICK SOLDIER I P 5 LEASE UNE COURSE, PANTO .. .. '4i I EXISTING BRICK SOLDIER 8" 3'-5 3/4" EXISTING (V.I.F.) 2'-3 1/4" V.I.F. 6'-O" 2'-3 1/4" V.I.F. 3'-5 3/4" EXISTING (V.I.F.) 8" COURSE, PANT / / / / / / / / / / ....._._.. _.__...._.�.... "� -.._.._.�.._ P-5 / -8 1/2" 20'-1 3/4" EXISTING (V.I.F.) 7 1/4"J / 1 22'-1 3/4" LEASE LINE DIMENSION / _ ----- .. ---- STOREFRONT PLAN ........ .. .__���.. ...... A 1 I SCALER yr - T-0' 1 I \ \ I, . e . , ... ., • ' �? EXISTING BRICK VENEER EXI MALL T—." WALL, PANT P_5 SOFF� TO REMAIN �IIIII LINE OF EXISTING ARCHED °' I EXISTING STOREFRONT EXISTING BRICK EXISTING BRICK I SOFFIT BEYOND .r........rr .�........... N SIGNAGE TO REMAIN ARCHWAY, PA ® ARCHWAY, PA ® Mm n \ ma I I II I I I I I I III........,-,..J C�Om mow N N MIN — — EXISTING BRICK VENEER IIIIIII■Mil EN MI WEI__=Iiiimonsislilli ---iainICIMMINIIMM11111■■■ WALL, PANT __.J If._ __._.__.1._ ire W> III Q 3 NI z ADJACENT TENANT J - // / /,, EXISTING BRICK SOLDIER STOREFRONT W. / -, COURSE. PANT P_5/i DD __ _ "\' v EXISTING BRICK VENEER I � /� // P I � _ . , `° L WALL, PANT p-5 i / \ �., a II N A 3/4" BLACK MIL. I. -eta,.............. ( ... n.. �- EXISTING BRICK SOLDIER NM REVEAL BY G.C. }�, . ._ ...,...._ o v' COURSE, PANT P_5 I S_MIII / �. I OI v, T NM / \ EXISTING NEUTRAL ° ,ig ME M PIER TO REMAIN Q 4. m z ii EXISTING REVEAL TO • /% // LEASE LINE �' � Z o REMAIN, G.C. TO / \ 5 Lt REPLACE IF REQUIRED • _ �m lig W - o EXISTING MAl TILE QI o I i TO REMAIN • .' t 410 Ciii c..0 %.11 g LEASE UNE Z IN \ \----[I / W � \ � EXISTING DRINKING FOUNTAIN _ ' z I •II ` 1111.1- I TO REMAIN i O M -TI. SIGNAGE NOTE Z I Q 1. G.C. TO REFER TO APPROVED SIGN SHOP DRAWINGS ° // ,/ /i / // // ,/ mow - - // FOR FINAL PLACEMENT PRIOR TO STOREFRONT / I / / I / CONSTRUCTION. `� c U W �\ — 1 2. SIGNAGE UNDER SEPARATE PERMIT BY SIGN VENDOR `� o NEW ALUM. FRAME %V/ NEW TEMP. GLASS DOORS NEW DOOR PULLS NEW ALUM. FRAME W ce I EXISTING STOREFRONT TEMP. GLASS STOREFRONT & ALUM. FRAME WITH BY G.C. TEMP. GLASS STOREFRONT EXISTING STOREFRONT g f SYSTEM TO REMAIN TRANSOM, BY G.C. SYSTEM TO REMAIN BRICK PAINT STAIN APPLICATION PROCESS; I E Z AFTER BASE COATS ARE APPLIED, USE SYNTHETIC SPONGE TO APPLY STAIN. aWW SQUEEZE MOST OF STAIN FROM SPONGE AND LIGHTLY APPLY STAIN TO THE M ., BRICK. AFTER APPLYING STAN WITH SPONGE USE SMOOTH PAINTERS RAG TO W BLOT BRICK. ALL TO PARTIALLY DRY AND REPEAT PROCESS. 8 - 0- NOTE: G.C. TO PROTECT GROUT FROM STAN. WIPE STAN FROM GROUT WITH 2 ^ 8 , STOREFRONT ELEVA11ON CLEAN RAG IMMEDIATELY. 2 yr • 1-0' .�:�1;.� _�. a.. ..... ._...., o 0 CONTRACTOR'S NOTE; �„� CC WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. 2 g' \ W �Q tiff SALE . CONTRACTORS MUST VISIT JOB SITE TO .. VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING O CC BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF, TO TENANT REPRESENTATIVE. N �- REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START 0 Cl) OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE COMPLIANCE CONDITONS AFTER COMMENCEMENT OF CONSTRUCTION. A5 1111111 AR F11 ' I,........_ --..,,i,., c.1.1., 01 7., ___,,..„?..,, ,,,,, , ,T.::: ,.. . .54 ,I. : 0, z. , _ tall . 1.4 81'-10 3/4" LEASE LINE DIM. ��� ---- "., ---- 7 EXISTING EXIT 01 REMAIN THERMOSTAT - SERVICE DOOR ADJACENT TENANT T-SHIRT FIXTURES • LEASE UNE SLATWALL (TYP.) . .°°.- -.----,. - - - - - - wa,•,v °r•rn: erg ,+ ,;rrw. yxr. , xz': ... ." 7 .,,. ,.;. ,, .0.,+•7SDf!. •,...:. w1riA•:.Y.., .f..Ff:.: OW*.}.ne OWN. lIM N fir.. hMk�l... ., 1. ff"'"'""._'.'"-1 MALL XISTIN POWER POLE - NDIE CORRIDOR d I ACCESSIB ROUTE ■ I SEE POWER NOTE' AREA DENOTES 44" . THRU ST R ACCESSIBLE ROUTE___\_, LASE UNE I - - _ _ . THRU STORE .-._ _ .....,..., f ` F-22 ir''' ' 1 i 0 % i , i 1 - _ 44" MIN. _._.._w_..._. rdi IBly12A0:. FR ' S' a o rnNGUI" SALES AREA F 10 10 I`� _ .. �� .. _. w� _. w, F-22 0 } L_- — .I ``' RELOCATED THERMOSTAT gill �� v D (,'�� I - J r T 7 IN SALES REMOTE CS NSO `3 . 4 ... w EQUIP• EM TRICAL I NSIUTIERW H T PCP M © - 1 Z I I © 1 I �_ _c,+ ..... 4.._..._....I (1) TO TT N Ems' I TO RLAIN— J 0 1jI — �� J CASH PATCH REPAIR MALL 1.000 IIII - --� ��� J I ) ,v FLOORING AS REQUIRED BODY JEWELRY CASES -- sSY SYSTEM MALL Ui i I/ EXISTING ,I ] 344-HIGH , , . { B 110p ' ° G.C. TO INSTALL TENANT PROVIDED EXISTING STOREFRONT —_ STOCKROOM ACCESSIB w FLAT METAL STRAPPING TO SIGNAGE ABOVE TO REMAIN Ai I — COUNTTEER ❑ • CLOSE GAP ON C/W. (TYP. OF2 I IN NO WORK THIS AREA �' N '�XI$TING \ _ 'III �' _ -24 ill_z_,-� TOILET R0(1 ,1111 410 11P 0_ ' _I EXIST `G .II ‘°� b p F-24 F-24 x LEASE UNE ITNG ROOIdI- � � 1 2AIOBC FIRE F-10 1 __. _..., , 1 _ \ ® �1 CUSTOM C RAP BY NTENN IANNTTEG.C. - 1 -1 ical. _ �1�u (3) FITTING ROOM HOOKS © /w ] TO REMAIN.• h I 1111 :-, .- -ifow! ..l.�l± mom— I/�' '•—, f 7 r, -'-,:$ .' '1 "... n»�n. �!an,: nnan !.... 1,11•• n WWI,Nir“,J il Y SYI�..! !•Mm ...'<M�'. .... _ .. . / / ? r/C� r�/� !� 'L hii'w. !� .mow .,w.w.!Nn,. wiwe w!q.. nwMi+F.NN. "!!^7" .! , ........ WPM MOM MOM n...4I 411fkb WiWV MN�W. M..i.f, r.— Af ":� jr ., < /. i :: .i..W lfi I.-.1.. F .-,:ii{wif. .n....i iwWf.i fiirilF Mi�il 3+lif.N „pi nKY..K'Kni.fl( .WfyfW' •..•.f4Kii._ Fi K�( f .f.�iifk� ..,..,...... ..._ YW...W1WP ........ •......f 4. i...Y Lf•f•IY'Wa..Y / /..,.' , '`'. u�; i..6.Y'1...W- LWYG Y.Wtl � �Ifff.ftl"Y.W. .. .O•Wff. -,.:..,,.YYYY YYW.WWY •...aff..,,.,.,, .YWY'YYfIW �� XX gMIR" NGWROOt ' Rr{ 24• DEEP FIXED SEAT T-SHIRT FIXTURES U ASE UNE /\ } IN ACCESSIBLE FITTING MOUNTED 0 TO REMAIN. ROOM TO REMAIN. ADJACENT TENANT SEAWALL TIII(7_ FIXTURE / FLOOR FINISH PLAN ...__._...,,..._...._,.,, SCALE' 114' NI T-0' - . .......... „ NOTUSED �.,,.. . q_conhourdiane r 2 SCALD N.T • 1 AIININNIIIIII Antenna overview I ... Table 1.Manna -1 cNi ` Pmt of an UkraM I� system� Door Nax rrnna*NOW 215 Cori mm-. .._. .. .._ Doer-Mot oniennen Midi tathe Wd 'doofiome �, ■ �„�, 0 '1'' s+ulro�xdnQ an oAt.I *,Iwo Dlxot 11 _w._ W . w... ... . ( t)'Ian On 1l as t+ano nil�ws,lads,: I c if-1) W, or r�by con thane to r e 1 �Mx r� A.G,F.H. STAINLESS RECESSED ALUMINUM STAINLESS 21.or IJ � '1 I STEEL TOP-\,1/4 SLAT WALL STEEL TOP • Wide'< a Oen by when a i c� A,0,F,H, [•' �1 \ _ Plus sawn&es added: _ ••` �a In Tate I. . B A D E i' #i1!' r 1i�t or POWER NOTES I--- cNv ADA I ® is the use c a send 1. CONTRACTOR TO RECONNECT CASHWRAP TO EXISTING CASHWRAP CIRCUITS, • Of O' @aor Ilan, wAigarawrMur t;Rtr�s l rr N • •= • G.C. TO EXTEND POWER FROM PREVIOUS LOCATION -rp NEW AS REQ D. © � COORD. WITH MALL MANAGEMENT G.C. TO PROVIDE 3 POWER POLE l r�• 0 q= TO EACH CASHWRAP SIDE, COORD. W/ HOT TOPIC P.M. . Q r � �t• �'�lilax antenna l>� 1 �T4na+�l�rr A��H,K,L,M.NI _ mow. �.-..... CASHWRAP 2. CONTRA TOR TO LABEL / RELABEL ALL BREAKERS IN THE ELECTRICAL© '�I A 1 P/WEL(S� do EQUIPMENT PER FIELD CHANGES AND SITE CONDRIONS.IIII •SCAM 1/4' T-0�' _ ' d © t . , H� H 3. G.C. TO REPLACE ALL RECEPTACLES IN SALES AREA AND STOREFRONT Q. ... .� WITH A BLACK RECEPTACLE AND BLACK PLATE COVER. G.C. TO CONFIRM _. .__. _ .._ . ,�• -t L:IoI0 `. �Illal►�III 1I 1 Raw orReadvet EXACT AMOUNT AND LOCATIONS ON SITE. 2 Dow-Max Transosivere III t •H• ,L►lit.m € , �' '�'�+' 4. DUPLEX RECEPT LES AT THE CASHWRAP ARE TO BE LOCATED CENTER k•FV?" Rain Alone ". 2 De ist �roionrs It It. ,H.1t,1 M.t4 OF EACH POS OFF THE BOTTOM SHELF. PHONE AN COMPUTER W ! © .. 1 PIooif oc IP1 JACKS ARE Td BE MOUNTED TO THE LEFT OR RIGHT 3�ABOVE THE I P3000 UNISTRUT - PAINT P-1 © D 0 ' Thwrnluor BOTTOM SHELF. ....-. .. . _ ._ .�ri %, 5. 6NNY DaSTIN RECEPTACLES ABOVE 18' ON THE SALES AREA TO BE FIXTURE LEGEND , THREADED ROD TO STRUCTURE ABOVE 0 ► r '� .. , A. , ., sAFm OF AND ABANDONED OR RELOCATED TO 18 A.F.F. I PAINT �, ME GUMMY =BM OE9aW'110N P-1 NOTE: �� © � 1 plil lMncA�s O G.C. TO COORDINATE ALL WIRING 0 V Y4 © 1 P�lir r i"JK[i 1 QE1M )I C. NOTE F-27 1 o EXISTING NESTING TABLE AND RECEPTACLE LOCATIONS WITH ����iiii 0 1 U BOLT ATTACHED T SIDE OF FIXTURE DRAWINGS AND HOT ��� 0 Er 1 F1aOI S tP J$ MtIM1 1. G.C. TO REVIEW BILL OF LADING UPON RECEIPT OF ALL SHIPMENTS. ANY _ 2 E BLACK MANNEQUIN W/ STAND E g UNISTRUT - PAINT P_1 TOPIC P.M. PRIOR TO INSTALL. F. 1 ) DAMAGES OR SHORTAGES ARE TO BE INDICATED AT RECEIPT, OR WITHIN . tiirl�1r!i1111i1'' 16 G. 1 p p� ) 11 24 HOURS. FAILURE TO DO SO WILL REQUIRE G.C. TO CONTACT VENDORS F-10 4 W NEW OPEN 2-WAY �, J . O1 DUPLEX RECEPTACLE MOUNTED IN CASH/WRAP COUNTER. 1 � q fTLED0:RAG"E.AND PURCHASE SAID ITEMS AT G.CCOST. ° °'� T g ce ////////////////////// VERIFY IN FIELD H. 1 Prwwrd F-10 4 DOSTING OPEN 2-WAY ° 'Q• ® DEDICATED DUPLEX RECEPTACLE, HUBBELL OR EQUAL MID. IN CASH WRAP COUNTER. „ 2. OF TENANT SUPPLIED ITEMS ARE TO BE STORED IN (HUBBELL EQUAL) / � •�, F 3 NEW BODY JEWELRY e5 CEIUNG • (WHERE OCCURS) P-1 *'�` IatIVNrCan� t.+0151T 1 —� 3 FOUR PHONE/COMPUTER JACK IN CASH/WRAP. TWO RJ-45 CONNECTIONS AND ONE RJ-14 DUAL ..,.. x ,•t 3. G.C. TO PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY CODE. G.C. TO o P.,11 SEE POWER NOTES ON SHEET A6. y`_ •,-.. .•.....-, •,..'- + ' U It liPro `1 11 Idlii•A6a'>r- f F-16 2 - .____.. ”" ALSO PROVIDE THE FIRST SERVICE TAG WITH DATE PRIOR TO TURNOVER. 8 EXISTING 2-WAY POST �. PORT CONNECTION. •".i'.lI�IIItt,6 Vib+lw�r# 1 �•011r4Ir "' I 3 SCH ULE 40 THREADED STEEL PIPE 1I 4. GC TO REPORT ANY MISSING PIECES OF VENDOR SUPPLIED SHELVING F-24 4 e IXISIING ACCESSORY FIXTURE Oil PAINT. ® IF NOT EXISTING, PROVIDE A DELIVERY BUZZER SYSTEM SIMILAR OR EQUAL TO EDWARD'S �° i"' WITHIN 48 HOURS OF RECEMNG ORDER, FAILURE TO DO SO WILL Cn COMPLETE WITH TRANSFORMER, PUSH BUTTON, BUZZER OR CHIME. E.C. SHALL PROVIDE ALL J � ) RESULT IN C.C. HAVE TO REPLACE AT OWN EXPENSE. F-24 3 NEW ACCESSORY FIXTURE ,� CONDUIT FOR POWER. STEEL THREADED BOLTED TO J-BOXES, CONDUITS & WIRES TO COMPLETELY INSTALL THE SYSTEM. FIELD VERIFY PRIOR TO BID. �I M; �'I aIrZP Z K a iodate(21000 -.n:: CASHWRAP. PAINT t , GC-42 2 , NEW GLASS STICKER CASE �.` ,�..� ce P-1 ® SWITCH AND ROUTER FOR CASH/WRAP SYSTEMS IF EXISTING NOT BEING REUSED. G.C. TO L. 2 01O ) - CONTRACTORS NOTES' _ COORDINATE WITH HOT TOPIC P.M. TNt,Q0,1/4032.RCP,Its,'3t"�-1 ` - 3 � DUSTING 36' ROUNDER W -- ,...... �_ 1. WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. �0> imiiilllinnithilll!Illllli_III!Illllltminniall i....i lllinimininilll;llllll t1 1)' N 6 TYP. POWER POLE LOCATION, SEE PLAN ABOVE FOR CORRECT SIDE OF CASHWRAP - G.C. TO M, p i4to .SALE DRAWINGS. CONTRACTORS MUST VISIT JOB SITE TO w° > 1�. 1 1 •4i) FT-4 1Q NEW 36' ROUNDER m W G.C. TO DRILL OPENING IN CASHWRAP CASHWRAP CONSTRUCTION SHOWN FOR REFERENCE BRING POWER TO CASHWRAP THROUGH POWER POLE AND ROUTE TO NEIGHBORING CASHWRAP VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING `:; N c) r FOR CU CONDUIT. ONLY. VERIFY WITH FIXTURE VENDOR. AS REQUIRED - TYP. EACH SIDE. BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY _ 1 'mEntIm NEW LCD 1V INTERFERE WITH THE PROPER EXECUTION OF, TO TENANT REPRESENTATNE � �-i I CASHWRAP POWER POLE DETAIL TYP. CA P DETAIL - 1 I I EXISTING IMPULSE FIURE 4 5 DIC4TAL DOOR-MAX SYSTEM COMPLIANCE CONDITIONS AFTER COMMENCEMENT OD CONSTRUCTOIONCODE N SCALD N.T� SCALE; N.1.8 6 O LL SCALD TIE 2. FIXTURE PLAN, FLOOR PLAN, INTERIOR ELEVATION SHEET, REFLECTED - 1 CASH WRAP A CEIUNG PLAN, DEMOLITION PLAN ARE OF THIS SPECIFIC STORE. DETAIL SHEETS ARE GENERAL AND MAY OR MAY NOT BE STORE SPECIFIC. A6