Specifications T u.pzo )3- ooZ601 I2 ooh s' ) Ma rl CONSULTING 503. .4 503.222248.926453 3 E N G I N E E R S vlmk @vlmk.com 3933 SW Kelly Avenue • Portland . OR • 97239-4393 www.vlmk.com STRUCTURAL CALCULATIONS for DR. SIERK DENTAL TI DRIVE THRU 12000 SW Main Street Tigard, OR for Norwest Contractors PO Box 25305 Portland, OR 97225 t��`;=D PPQF-4,„Z CP, ON =.�- ;- EXPIi FES: G-33-2019 I Prepared By: Stephen Stenberg, E.I.T. VLMK Job Number: 20130564 December 12, 2013 I Structural Engineering•Civil Engineering•Industrial Engineering•Planning•StudieslEvaluations•Entitlement VI_MK Consulting Engineers, Inc. Structural Calculations DC-1 Dr. Sierk Dental TI Drive Thru Dr. Sierk Dental TI Drive Thru 12000 SW Main Street Tigard, OR VLMK JOB NO. 20130564 STRUCTURAL CALCULATIONS FOR BUILDING PERMIT TABLE OF CONTENTS Design Outline and Criteria DC-1 thru DC-2 Lateral Load Design L-1 thru L-8 DESCRIPTION OF STRUCTURAL SYSTEM The 'Dr. Sierk Dental TI Drive Thru' project consists of the renovation of an existing building located on 12000 SW Main Street, Tigard OR. The scope of work includes the infill of an existing drive thru canopy structure. This package includes structural calculations verifying the adequacy of the existing shear walls to resist the out-of-plane loads. ***LIMITATIONS*** VLMK Consulting Engineers was retained in a limited capacity for this project. The design is based upon information provided by the client, who is solely responsible for the accuracy of the information. No responsibility and/or liability is assumed by, nor is any to be assigned to, VLMK Consulting Engineers for items beyond that shown in this Structural Calculation Package. File:G:1 Acad2 01 31201 30564\CalculationslPhase 2 Drive Thru\20130564-DC Drive Thru.docx Page 1 Printed:December 11,2013 Structural Calculations DC-2 Dr. Sierk Dental TI Drive Thru DESIGN CRITERIA CODES: 2010 Oregon Structural Specialty Code (Based on the 2009 International Building Code) DESIGN LOADS: Live Loads: Roof Snow Load Flat Roof Snow Load, Pf 25.0 psf Snow Drift As Required Dead Loads: Roof (Panelized) Roofing (new and future) 4.0 psf Insulation 1.5 psf Sheathing (5/8" plywood) 1.8 psf Sub-purlins (max 3x6 at 24") 1.2 psf Joists 3.0 psf Girders 1.0 psf Mechanical and Electrical 1.0 psf Miscellaneous 1.5 psf Total Roof Load 15.0 psf Wall Weights - Wood-stud Exterior Walls 15.0 psf Wind: Basic Wind Speed (3-second gust) 95 mph Wind Importance Factor, Ir„ I = 1.0 Occupancy Category II Wind Exposure B Internal Pressure Coefficient GCD; _ +/- 0.18 Seismic: Seismic Importance Factor 1.0 Occupancy Category II Mapped Spectral Response Accelerations Ss = 94.4% Si = 33.9% Site Class D Spectral Response Coefficients Sds = 70.6% Sdi = 38.9% Seismic Design Category D Basic Seismic force resisting system(s) Light Framed Wood Wall Seismic response coefficient(s) C5 = 0.078 • Response modification factor R = 6.5 Analysis procedure used Equivalent Static File:G:1Aced201 312 01 30 5 641CalculationslPhase 2 Drive Thrul20130564-DC Drive Thru.docx Page 2 Printed:December 11,2013 Design Maps Summary Report http://geohazards.usgs.gov/designmaps/us/summary.php?template=mini... Design Maps Summary Report I L_s I • User-Specified Input Report Title Dr. Sierk Dental TI Tue October 8,2013 20:16:45 UTC • Building Code Reference Document 2006/2009 International Building Code (which utilizes USGS hazard data available in 2002) Site Coordinates 45.43295°N, 122.76682°W Site Soil Classification Site Class D -"Stiff Soil" Occupancy Category I/II/III 1 , 14.0 a i:r:`..�.. `3,i e T. . ti � # i' r = i adz S t .} �1 } °. i � . d � r k f a 4f aF3- tK a� h • + a ,-X t .._ r � y; R 31 i • j USGS-Provided Output S = 0.944 g SMS = 1.060 g SD$ = 0.706 g S = 0.339 g S 0.584 g SD1 = 0.389 g MCE Response Spectrum Design Response Spectrum 1.10 0.72 0.99 0.64 _. 0.00 0.51 0.77 0.40 a 0.66 1 a 1 0.40 ass ; ta 0.32 0.44 a n 024 0.22 0.11 0.11 0.D0 a00 0.00 0.00 0.20 0.40 0.617 0.00 1.00 1.20 1.40 1.60 1.00 2.00 0.00 D.20 D.40 0.60 0.00.1.00 1.20 1.40 1.69 1.00 2.00 Period,T(sec, Period.T(sec) • Akhough this information is a product of the U.S.Geological Survey,we provide no warranty,expressed or Implied,as to the.acaracy of the data contained therein.This tool Is not a substitute for technical subject-matter knowledge. 1 of 1 10/8/2013 1:18 PM CONSULTING P 503.222.4453 Job Dr. Sierk Dental -TI E-N G I N E E R S F 503.248,9263 Job No. 20130564 3933 SW Kelly Avenue • Portland • Oregon 97239-4393 E vlmk @vlmk.com Date 10/13 Vv www.vlmk.com v2.00-Software Copyright 2010 VLMK Consulting Engineers. All Rights Reserved. Sheet No L-2 Wind Loads - Main Wind-Force Resisting Systems Based on the 2009 International Building Code and ASCE 7-05, 6.4 (Method 1 -Simplified Procedure) Exposure Category [Section 6.5.6.3] Kn = Topographic Factor [Figure 6-4] I = Importance Factor[Table 6-1] Roof Slope = Degrees • V = ; Basic Wind Speed 3-Second Gust [Figure 6-1] Per ASCE 7-05, 6.4.2.1 and Figure 6-2 Horizontal Loads Height Adjustment End Zones Interior Zones (ft) A (psf) (psf) Wall (A) Roof(B) Wall (C) Roof(D) 15 1.00 14.4 -7.5 9.5 -4.5 20 1.00 14.4 -7.5 9.5 -4.5 • 1 CONSULTING 503.222.4453 Job Dr. Sierk Dental - TI E N G I N E E R S 503.248.9263 Job No. 20130564 3933 SW Kelly Avenue • Portland • Oregon 97239-4314 vlmk @vlmk.com Date 10/13 . www.vlmk.com v2.00-Software Copyright 2010 VLMK Consulting Engineers. All Rights Reserved. Sheet No. L-3 Wind Loads - Main Wind-Force Resisting Systems Based on the 2009 International Building Code and ASCE 7-05, 6.4 (Method 1 -Simplified Procedure) - / f '- � - , ' 0.--� .- f.t c '--< -' o 6-iii •„--"t 0 ill010 Alto, - il OP i,,• ' #,: A. ,,,,,,,,,, ilit , 1-:. 4".* l'•'lk ,44. .....0.449;tc4a46- ...r. 4.: - cm .... .,-- .7,-- e ip ),--r) Reteteaci\. ''''..:tle ,-/-. . Comer --......, 0 ti 1._ ,.."..r. I Transverse , . 4 a k.‘i,\.s. \.* 1 ,1..ie..#•,1 Longitudinal End Zone Length [Figure 6-2/Note #10] L = Least Horizontal Dimension h = Mean Roof Height 2 ft- Smaller of 10% of Least Horizontal Dimension 6 ft Smaller of 40% of Mean Roof Height 1 ft Not Less Than 4% of Least Horizontal Dimension 3 ft Not Less Than 3 ft 2a = 6 ft End Zone Length - CONSUNG Job W-' G(e-(2 4 t' V G T1-i• 1 VLMK ENGINLETEIRS C -,t N`JP-"`'•1' Job NoiCJl30S-44 By K-1"u- • 3933 SW Kelly Avenue • Portland • Oregon 97239-4393 1Z( III I-3 Sheet No. L--gi" Date Q 503.222.4453 503.248.9263 0 M Y:FtX i5 �Y'V -t�Sn Rtlr '.i•�f--i .w1. r-. a.t. it r�.4u wa .LMYit 8 a8 . 1--465-11.-- X:-o t t 1" i 1. i V_ CS "'� '.1 05 : i . .f TlieS:de { (12„,ii I). . i : ( M '> .....w ._ .. -4 r _ v� :o . l.�q u/ �, 09 ' � 1 I ..± /� .,,.-. ..,. 4 i i. . --ts"'IC.ci tUDtt-1 VI, = --0-'(:)116Elq-rse-6 ÷: Is et6t.4t,q - C.i-- -, ------ - - . 7 \N � $ .-c+ is 5f` Ci., /3)C27) 1� S 2 VI 410 ckrITt/- S d tcrtJ 'Y 1 5 P.�--T1 °r1 , CONSULTING Joba�'S� -� �(�vr �}� V L M K E N G I N E E R S Chant N°�''=�T • 3933 SW Kelly Avenue • Portland • Oregon 97239-4393 '�b`V ``� -_ P 503.222.4453 503.248.9263 Q Date 121■���� sheet No. W t -O(4(oTU P cAct W wtN a = 1k..et-,, ,f - ,,,�� : , , „, . .. . ... • -- A -s vsc-'..._ rir4t ; -24,rAel- -'--- ' .::-.. .el,:t..e----.5---s-i-e- r• _ __ . j f _ Fa Llt,ir. y.sr)_ 44 I.,c, 1•9_P$e V2' ; _7.- tIir,`. . ., z i t '_ V * .__ : ; : i • ' _ _ - _., _ _ - -r_!-Tyr-•-.� _. _- _ �_ V G = 1 -\ -�. 1-116446 l l52 pc�F $ cos �-t V= M l N1 1 M J M C 0 - l fl= S' % W vsli- 1 O Nett A-7- �" o c _ - -- - V L M K CONSULTING P 503.222.4453 Job Dr. Sierk Dental TI E N G I N E E R S F 503.248.9263 Job No. 20130564 3933 SW Kelly Avenue • Portland • Oregon 97239-4393 E vlmk @vlmk.com • �'� www.vlmk.com Date 10/13 v3.02-Software Copyright 2013 VLMK Consulting Engineers. All Rights Reserved. Sheet No. L- Wood Shearwall Overturning Analysis Based on the 2009 International Building Code ROOF/FLOOR LOAD Design Input P Floor DL . : psf Roof DL - psf lir WAS HEIGH Wall DL = psf•Tolerance � Ibs �^ Holdown Offset = . In (see Note 3) Load Combination = SDs = short period factor P up+ WIDTH .? Notes: 1. Input Seismic loads as 0.7E values. 2. Input Wind loads as 1.0W values. 3. Holdown Offset measured from centerline of holdown to end of wall. 4. Simpson Holdowns are based on a minimum 3 1/2" stud/post width (2x4 wall) except as noted. 5. At Simpson HDU14, HD12, and HD19 holdowns, designer is to verify anchor bolt requirements and post size &capacity considering effective post height. Shearwall Overturning Design, Wall (W)ind Roof Floor holdown Uplift Total Height Width Load -or- Trib Trib -or- MOT MRES Above Uplift (ft) (ft) (plf) (S)eis (ft) (ft) strap (lb-ft) (1b-ft) (Ibs) (Ibs) Holdown Required Drive Thru Exterior Line ,s'pr ° w > , f A k i 'r 13376 5472 ,, 1054 DTT2Z 2-7 SIMPSON Anchor DesignerTM Company: VLMK Date 10/9/2013 Engineer: SMS Page: 1/2 Strong-Tie Software Strong Project: Dr.Sierk Dental-TI • Version 2.0.4896.6 Address: Phone: E-mail: 3.Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Naa(lb) Vaax(Ib) Vuay(Ib) I(Vuax)2+(Voay)2(lb) 1 1961.0 0.0 0.0 0.0 Sum 1961.0' 0.0 0.0 0.0 Maximum concrete compression strain(%o):0.00 Maximum concrete compression stress(psi):0 Resultant tension force(Ib):1961 Resultant compression force(Ib):0 Eccentricity of resultant tension forces in x-axis,e'rtt(inch):0.00 Eccentricity of resultant tension forces in y-axis,e'ny(inch):0.00 4.Steel Strength of Anchor in Tension(Sec.D.5.1) Ma(Ib) 0 ON.(Ib) 8095 0.75 6071 5.Concrete Breakout Strength of Anchor in Tension(Sec.D.5.2). Nn=kc14foher1 s(Eq. D-7) ke A f (psi) her(in) Nn(Ib) 17.0 1.00 2500 4.000 6800 0Nm=0(AN./An.)ne,NYcNWon,NNn(Sec. D.4.1 &Eq.D-4) Ank(in2) Anion(in2) 'Yee,N Vc,N 'fcp,N Nn(Ib) 0 ,ONw(Ib) 108.00 144.00 0.850 1.00 1.000 6800 0.65 2818 6.Adhesive Strength of Anchor in Tension(AC308 Sec.3.31 rk,or= rk,rrfshort-rermKsal rx.cr(psi) fshort-term Ksof nca(psi) 995 1.00 1.00 995 Nao=rx,Q2rdaher(Eq.D-16f) zk„(psi) di.(in) her(in) Nao(Ib) 995 0.50 4.000 6252 ON.=0(ANa/ANao)'Ye1Ne`'ewoNeo(Sec.D.4.1 &Eq.D-16a) ANa(in2) ANao(in2) y%qN, Svp,Na Nao(Ib) 0 ¢N•(Ib) 108.00 144.00 0.850 1.000 6252 0.55 2192 • Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.5%0.9000 Fax:925 847.3871 www.strongtie.com I 1- e SIMPSON Anchor DesignerTM Company: VLMK Date 10/9!2013 Engineer: SMS Page: 2/2 Software StrongTie Project: Dr.Sierk Dental TI • Version 2.0.4896.6 Address: Phone: E-mail: 11.Interaction of Tensile and Shear Forces(Sec.D.71 Tension Factored Load,N.(Ib) Design Strength,eNn(Ib) Ratio Status Steel 1961 6071 0.32 Pass Concrete breakout 1961 2818 0.70 Pass Adhesive 1961 2192 0.89 Pass(Governs) SET-XP w/112"0 A193 Gr.B8/B8M(3041316SS)meets the selected design criteria. 12.Warnings -Concrete compressive strength used in concrete breakout strength in tension,adhesive strength in tension and concrete pryout strength in shear for SET-XP adhesive anchor is limit to 2,500 psi per ICC-ES ESR-2508 Section 5.3. -Designer must exercise own judgement to determine if this design is suitable. -Refer to manufacturer's product literature for hole cleaning and installation instructions. Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strong-Tie Company Inc. 5956 W Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925 847.3871 www strongtie.corn bui2ZO ►3- 1502 1 VLMKCONSULTING 503.222.4453 E N G I N E E R S 503.248.9263 vlmkOvlmk.com 3933 SW Kelly Avenue . Portland • OR . 97239-4393 www.vlmk.com STRUCTURAL CALCULATIONS for DR. SIERK DENTAL TENANT IMPROVEMENT 12000 SW Main Street Tigard, OR for Norwest Contractors PO Box 25305 Portland, OR 97225 '(ocTU 1 A�'/'s 5„00 PRO,cer, S'EGO G 7- 23 ti [EXPIRES: 6-30-20/S , Prepared By: Stephen Stenberg, E.I.T. VLMK Job Number: 20130564 October 09, 2013 I Structural Engineering•Civil Engineering•Industrial Engineering•Planning•Studies/Evaluations•Entillement VLMK Consulting Engineers. Inc. r , Structural Calculations DC-1 Dr. Sierk Dental — Tenant Improvement Dr. Sierk Dental Tenant Improvement 12000 SW Main Street Tigard, OR VLMK JOB NO. 20130564 STRUCTURAL CALCULATIONS FOR BUILDING PERMIT TABLE OF CONTENTS Design Outline and Criteria DC-1 thru DC-2 Lateral Load Design L-1 thru L-9 DESCRIPTION OF STRUCTURAL SYSTEM The 'Dr. Sierk Dental — TI' project consists of the renovation of an existing building located on 12000 SW Main Street, Tigard OR. The scope of work includes the addition of multiple interior and exterior walls and the removal of (2) exterior walls at the front entry of the building. This package includes structural calculations verifying the adequacy of the existing shear walls to resist the out-of-plane loads. • ***LIMITATIONS*** VLMK Consulting Engineers was retained in a limited capacity for this project. The design is based upon information provided by the client, who is solely responsible for the accuracy of the information. No responsibility and/or liability is assumed by, nor is any to be assigned to, VLMK Consulting Engineers for items beyond that shown in this Structural Calculation Package. File:G:lAcad2013\20130564tCalwla4onst20130964-DC.doa Page 1 Pr.nted.October 09.2013 Structural Calculations DC-2 Dr. Sierk Dental — Tenant Improvement DESIGN CRITERIA CODES: 2010 Oregon Structural Specialty Code (Based on the 2009 International Building Code) DESIGN LOADS: Live Loads: Roof Snow Load Fiat Roof Snow Load, Pr 25.0 psf Snow Drift As Required Dead Loads: Roof (Panelized) Roofing (new and future) 4.0 psf Insulation 1.5 psf Sheathing (5/8" plywood) 1.8 psf Sub-purlins (max 3x6 at 24") 1.2 psf Joists 3.0 psf Girders 1.0 psf Mechanical and Electrical 1.0 psf Miscellaneous 1.5 psf Total Roof Load 15.0 psf Wall Weights Wood-stud Exterior Walls 15.0 psf Wind: Basic Wind Speed (3-second gust) 95 mph Wind Importance Factor, IH, Iw = 1.0 Occupancy Category II Wind Exposure B Internal Pressure Coefficient GC„; = +/- 0,18 Seismic: Seismic Importance Factor 1.0 Occupancy Category U Mapped Spectral Response Accelerations S5 = 94.4% S1 = 33.9% Site Class D Spectral Response Coefficients Sd5 = 70.6% Shc = 38.9% Seismic Design Category D Basic Seismic force resisting system(s) Light Framed Wood Wall Seismic response coefficient(s) CS = 0.078 Response modification factor R = 6.5 Analysis procedure used Equivalent Static Fie:G:4A;ad201 3120 1 3 05541Calculation!420130564-DC.do x Page 2 Printed October 08,2013 Design Maps Summary Report http:/lgeohazards.usgs.gov/designmaps/us/summary.php?template=mini... LUSGS Design Maps Summary Report L--1- User-Specified Input Report Title Dr. Sierk Dental TI Tue October 8,2013 20:16:45 UTC Building Code Reference Document 2006/2009 International Building Code (which utilczes USGS hazard data available in 2002) Site Coordinates 45.43295°N, 122.76682°W Site Soil Classification Site Class D - "Stiff Soil" Occupancy Category I/II/111 1.- _-;� ,-„ Jiic7Rre[ a 4 t x 't - . verto 1=04 --? ,ref- ry..i. 7 3 k.` ,_, 4 J• alt r► , �v&-y - , . ' L _ s - r" - ' _ i" - - Ittnap _ F .- _''4. rd r _ i s' .. 1 .•• 4, o= 1.' . 4 - err-. ie' -_ .., -:• _ �_ _ ._. . .__. _..� �^'IF ' � z*Von L i _-- -v p� a s x� - t i k w -- - r t �--'° . l3 . -..�.m 11dP4aest USGS-Provided Output SS = 0.944 g S = 1.060 g S05 = 0.706 g Si = 0.339 g SMI = 0.584 g S0 = 0.389 g MCE Response Spectrum Design Response Spectrum 1.10 0-72 0.99 0.61 0.22 0.56 0.77 0.45 C 0.66 r to H 0.55 t IA 0.40 ) D.32 0.44 0.73 0.24 0 22 0.16 0.11 0.06 0.00 0.00 0.00 0.20 0.40 0.60 0.20 1.00 1.20 1.40 1.60 1.20 ZOO 0.00 0.20 0.40 0.60 0.20 1.00 1.20 1.40 1.60 1.50 2.00 Period, T Isec) Period,T Isec) Although this information is a product of the U.S.Geological Survey,we provide no warranty,expressed or Implied,as to the accuracy of the data contained therein.This tool is not a substitute for technical subject-matter knowledge. I oft 10/8/2013 I:18 PM CONSULTING P 503.222.4453 Job Dr. Sierk Dental -11 VLMK ENGINEERS r 503.248.9263 Job No. 20130564 3933 SW Kelly Avenue Portland • Oregon 97239-4393 vlmk @vlmk.com Date 10/13 • '�'� www.vlmkcom v2.00-Software Copyright 2010 V1.111(Consulting Engineers. All Rights Reserved. Sheet No. "2 Wind Loads - Main Wind-Force Resisting Systems Based on the 2009 International Building Code and ASCE 7-05, 6.4 (Method 1 - Simplified Procedure) Exposure Category [Section 6.5.6.3] KZt =rte:',`:.-s'gy='~ _Topographic Factor [Figure 6-4] I =1- j` i01-->=Importance Factor [Table 6-1] Roof Slope Degrees V =tWO----577W07-tI,:-Basic Wind Speed 3-Second Gust [Figure 6-1] Per ASCE 7-05, 6.4.2.1 and Figure 6-2 Horizontal Loads Height Adjustment End Zones Interior Zones (ft) A (psf) (psi) Wall (A) Roof(B) Wall (C) Roof (D) 15 1.00 14.4 -7.5 9.5 -4.5 20 1.00 14.4 -7.5 9.5 -4.5 ING I S03.222.4453 Job M E N G s N ETE R S r 503.248.9263 Job No. 220130564 Dental --1-1 3933 SW Kelly Avenue • Portland • Oregon 97239-4314 E www.v vlmk @ mkvlmk,com com Date 10/13 v2.00-Software Copyright 2010 VLMK Consultlng Engineers. All Rights Reserved. Sheet NO. Z'3 Wind Loads - Main Wind-Force Resisting Systems Based on the 2009 International Building Code and ASCE 7-05, 6.4 (Method 1 -Simplified Procedure) " ter -. ,ter '--1.1:-1-. -f-r----. 4,1 .- 1-,, _ I 1-1-1.;fi .-- 1 .,,..,®1:01 L. ji I} .- YYY �, :=i":.f: ...„-•" N....* ..><>- ,.. „5„." .„.■ ...„- 101111.111t , ---1; ,,'-- 42tv 46%,`fir ` .1.•^� _ ,y j ,. k - ' Ca nar ` A)` e E I,te3s- „..t.. .... p,._, ,, ,,Transverse - - ” e_rAe i.‘,..,�, \ i - ��i riere ce s , Cotner Longitudinal End Zone Length(Figure 6-2/Note #10] t L = 5 Least Horizontal Dimension h = 5 t: Mean Roof Height 2 ft Smaller of 10% of Least Horizontal Dimension 6 ft Smaller of 40% of Mean Roof Height 1 ft Not Less Than 4% of Least Horizontal Dimension 3 ft Not Less Than 3 ft 2a = 6 ft End Zone Length CONSULTING job Di. 5xe,ck 04-s-14 ►r E N G I N E E R S Client .Pcrays,er fo.�sT .Job No. Zia'1G470 Y gy 5,1 g • 3933 SW Kelly Avenue • Portland • Oregon 97239-4393 gi 503.222.4453 503.248.9263 ® °ate io,//3 sheet No. L-41 1A P IAL Al.,,Atysss .5 r >,c • LS . W rAsaE >-oS J_saa iz.g;1 sos (R4 ?-o tA✓ n a-e'1 • s d+yogi X.d v R (Croon- ff,rix.n 1-woo.. ti,Avr.) Cs : o. /al V• 0,/al W rvtr a a.Jo•1 w a a. o)8 rAfy _ • lo�,Gz,�,fls,.►ai .. w . 0.0%, r!cr, (57+ ) f' iSr ("433A )(2,,A,4S ) >> P'.� P • 1.444.-"S T-PoPsvf1G3+E • 141,)et 0.o,8 fir/3%P- (3s. t 1 S p5t (!`-34A. 7 wAws = S- 1 -►a eop rags rte;,, CONSULTING Job Dt- 3-40 DF..�u•- rr • E N G I N E E R S Cient '44'4rsr (ams'-. 3933 SW Kelly Avenue • Portland • Oregon 97239-4393 Job Na. ZoI3asr,y By SMS GI 503.222.4453 503.248.9263 0 Date )n/,3 Sheet No. L-5 • IAA-re/Ai- ,d •AL-y4rS (1,P44 Nr►aid • 19MGZ1vA3r1.4L 0 �+CE P`u a 20.15 Lc `J f;`_..._.,.... • t 9,s P'ir• rr,.rr, 20.`•E fG (iv.yPsF a 23.3 (1.1" _3[-4-' , z . 1.3.8 ' • a - E(i I-(l5'sf f•sF}, + 5's 14- ( is, ) .) i. ..J. ..z...,�./ k • s _ - _.r.._..11...,11{. __. c • • • CONSULTING Jobe- '51-4•4k f>rr.14 - Tz E N G I N E E R S• CEenc 14n1LwESf e°• Sr. • 3933 SW Kelly Avenue • Portland • Oregon 97239-4393 Jobrvo. 707i30S4Y By 5/16 P 503.222.4453 503.248.9263 Q Date /o/f 3 Sheet No L_ b IA7E/JA. 4.''iys 2s (oval.) WTNo La.+TF 4-s ✓3 s • V r s/ of o /f IQ k Et 10 Q W V L . , , rb \ K i , . ct Ar. - /DS 21°.. • LOAD L vLATZOrs k 1,380 r I ] . li: s / 38 N" : Ll r /1/8 PLF 3 B /O'-D" 45(1.•1 , 2,/to 4 I V, 7,11 k . = r 23o � , 9.1z'. L LoS LW) 1 •AsLS A-1- G" o.L. ALL ,o)"474- Bv6ES drill IL .' D.L. -row -L,rE,.p . ( V,,«.,4: Lilt/ POs ) CONSULTING 503.222.4453 Job Dr. 5ierk Dental TI V T . M K E N G I N E E R S 503.248.9263 Job No. 20130564 3933 SW Kelly Avenue Portland Oregon 97239-4393 vlmk @vlmk.com Date 10/13 • • www.vlmk.com v3.02-Software Copyright 2013 VLMK Consulting Engineers. All Rights Reserved. Sheet No. L ) Wood Shearwall Overturning Analysis Based on the 2009 International Building Code ROOF/FLOOR LOAD Design Input p _ . T=T=1`ZUZIZTTZTT=T= Floor DL =RV psf Roof DL = 15 O ..psf + W WTALL IE[GI-i Wall DL ==_f5.0__psf Tolerance = Ibs Holdown Offset =-_6D== in (see Note 3) Load Combination = SOS = : ._.r=:short period factor p wron► Notes: 1. Input Seismic loads as 0.7E values. 2. Input Wind loads as 1.0W values. • 3. Holdown Offset measured from centerline of holdown to end of wall. 4. Simpson Holdowns are based on a minimum 3 1/2" stud/post width (2x4 wall) except as noted. 5. At Simpson HDU14, HD12, and HD19 holdowns, designer is to verify anchor bolt requirements and post size &capacity considering effective post height, ShearWUall.Overturning Design Wall (W)ind Roof Floor holdown Uplift Total Height Width Load -or- Trib Trib -or- MOT MRES Above Uplift (ft) (ft) (plf) (S)eis (ft) (ft) strap (lb-ft) (1b-ft) (Ibs) (Ibs) Holdown Required - Line 1 _ µ,1 1W �.9' =24r W 4� W0... LT-strep= 25047 6616 WE ' 1961 STHD14 Line B �31_fJ 8 mm W 7.43.E _0 0 -vo downy 12617 5676 957 DTT2Z (M. ) 5'04 o'V '111•41"-Z£E Aa•✓' (741-4-0•1/ 3,sca —B SIMPSON Anchor DesignerTm Company: VLMK Date: 10/9/2013 Engineer: SMS _Page: _ 1/2 Strong-Tie Software Project: Dr.Sierk Dental-TI • Version 2.0.4896.6 Address: Phone: E-mail: 3.Resultlrlg Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, N. (Ib) Vo..(Ib) V..,(Ib) Y(V...)a+(V.ay):(lb) 1 1961.0 0.0 0.0 0.0 Sum 1961.0• 0.0 0.0 0.0 Maximum concrete compression strain(%o):0.00 Maximum concrete compression stress(psi):0 Resultant tension force(Ib):1961 Resultant compression force(Ib):0 Eccentricity of resultant tension forces in x-axis,e'H.(inch):0.00 Eccentricity of resultant tension forces in y-axis,e'Ny(inch):0.00 4.Steel Strength of Anchor in Tension(Sec.D.5.11 N,e{Ib) 0 ¢•:.(Ib) 8095 0.75 6071 5.Concrete Breakout Strength of Anchor in Tension(Sec.D.5.21 Nb=kci1 4fcher'•S(Eq.D-7) kc Pc(psi) he(in) Nb(lb) 17.0 1.00 2500 4.000 6800 0Nco=0(Ark/ANco)VagN T'c,N'rp,nrvb(Sec.D.4.1 &Eq.D-4) Ark(in2) ANCO(in2) y%,N 'Yc,N V.p,N Nb(Ib) ¢ 9Nm(Ib) 108.00 144.00 0.850 1.00 1.000 6800 0.65 2818 6.Adhesive Strength of Anchor in Tension(AC308 Sec.3.31 rkc= nr,of,barrlemrKsa! nca(psi) f,aoy term Kre! rkc(psi) 995 1.00 1.00 995 N.0= rkvrrdaher(Eq.D-161) rk,or(psi) do(in) her(in) Na0(Ib) 995 0.50 4.000 6252 0Na=¢(AN,/ANao)Vcamc%NAL('(Sec. D.4.1&Eq.D-16a) AN,(in2) AN.o(in2) yr gr„ gjp,Na Nao(Ib) 0 ¢Na(Ib) 108.00 144.00 0.850 1.000 6252 0.55 2192 Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. Simpson Strcrg-Tie Company Inc 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:525.847.3871 www.stronghe.com 1- 1 SIMPSON Anchor Designer TM Company: VLMK Date. 10/9/2013 Engineer: SMS Page: 2/2 Strong-Tie Software Project: Dr.Sierk Dental-71 • Version 2.0.4896.6 Address: Phone: E-mail: it Interaction of Tensile and Shear Forces(Sec.D.71 Tension Factored Load,N.(Pb) Design Strength,iaNr.(Pb) Ratio Status Steel 1961 6071 0.32 Pass Concrete breakout 1961 2618 0.70 Pass Adhesive 1961 2192 0.89 Pass(Governs) SET-XP w/1/2"0 A193 Gr.B8/B8M(304/316S5)meets the selected design criteria. 12.Warninas -Concrete compressive strength used in concrete breakout strength in tension,adhesive strength in tension and concrete pryout strength In shear for SET-XP adhesive anchor is limit to 2,500 psi per 1CC-ES ESR-2508 Section 5.3. -Designer must exercise own judgement to determine if this design is suitable. -Refer to manufacturer's product literature for hole cleanino and installation instructions. Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. oanpson Strong-Tie Company lac. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.8473871 w •w.strongtie.com