Loading...
Report PS20/•!S- OG 11 1 (a (35 3U' `702hd. HYDRAULIC DESIGN INFORMATION SHEET - . I NAME B/P/J 4e.:A2 T A/cT�IBvTON DATE /2/ // i3 LOCATION /&(e SW-7Z^)C4tE 77 4 �DL BUILDING OBP /3LQG. 1010) SYSTEM NO. CONTRACTOR .N I ', i ✓.LLD, CONTRACT NO, CALCULATED BY 15,1106 ' ' ' A" DRAWING NO. CONSTRUCTION: k'COMBUSTIBLE ❑ NON-COMBUSTIBLE CEILING HEIGHT FT. OCCUPANCY ic/AfEii eV;/N4 til NFPA 13: ❑ LT. HAZ. ORD. HAZ. GP. ❑ 1 ❑ 2 ❑ 3 ❑ EX. HAZ. rg NFPA 231 N. NFPA 231C: FIGURE ; CURVE 0 ❑ OTHER (Specify) W ❑ SPECIFIC RULING MADE BY DATE 0 w• AREA OF SPRINKLER OPERATION 2000 YS_ aLEM TYPE DENSITY +29 2 WET ❑ DRY O DELUGE Q PRE-ACTION >- AREA PER SPRINKLER 1 DC, SPRINKLER OR NOZZLE HOSE ALLOWANCE GPM: INSIDE — MAKE. LeMTIal- MODEL HOSE ALLOWANCE GPM: OUTSIDE 500 SIZE jilt_ _ K-FACTOR 5.6 RACK SPRINKLER ALLOWANCE TEMPERATURE RATING 11160 :pv,z Ac� IL_g.co CALCULATION GPM REQUIRED PSI REQUIRED_ AT BASE OF RISER . SUMMARY "C" FACTOR USED: OVERHEAD UNDERGROUND Y19IER FLOW TEST PU;,1P_DATA TANtS.O115ESSERVOIR • } DATE & TIME _ RATED CAPACITY CAPACITY J a STATIC PSI /03 AT PSI ELEVATION - RESIDUAL PSI GtZ ELEVATION D GPM FLOWING 114+ WELL w ELEVATION PROOF FLOW GPM • LOCATION I 810 04 /1o/2 ig. o/ S'/W e ©gP1-3 SOURCE OF INFORMATION Q ClM0��� I LOCATION COMMODITY SCO4 4/2 Ifi1 G�ONIi/A i!ZS CLASS w STORAGE HEIGHT_—_.-_1 AREA - _- AISLE V,IDTH Q• STORAGE METHOD: SOLID PILED % PALLETIZED % RACK cc O ❑ SINGLE ROW CONVENTIONAL PALLET ❑ AUTOMATIC STORAGE ❑ ENCAPSULATED >- 0 DOUBLE ROW 011 SLAVE PALLET [7] SOLID SHELVING ® NON- E- . ❑ MULTIPLE ROW [7 OPEN ENCAPSULATED Y - -- -- - - -- -- --- ----- o a FLUE SPACING IN INCHES CLEA 'ANCE FROM 10P OF Si ORAG_ TO CEILING O LONGITUDINAL TRANSVERSE - 4 - FT. 0 IN. HORIZONTAL BARRIERS PROVIDED-__._ - --- .0,0 PR ac - /SO Form SPRS-9 ' 4"GIN�F'9�p4 . r - ' 6 OREGON / HD. ' 6xPIRs.v(jd HYDRAULIC CALCULATIONS . JOB NO. 6PL .- 1 - - DRAWING NO.- --------- SHEET NO. r OF _2 - NAME BR(a Ek02 r L! S /$(ll`f o4._ ___ BY 5•ii4.0.0"J LOCATION 193, [�L0 •' /b - S'tS% Z DATE (119/13 . Zg PM vivo 50. j. /OOS.. T D. 20,,•S. owbw4 NOZZLE FLOW Fl NG FRICTION HYD. TYPE & IN PIPE PIPE EQUIV. LOSS REQUIRED REF. PT. ELEV. NOTES LOCATION G.P.M. SIZE DEVICES LENGTH P.S.I./FT. P.S.I. • Q LGTH. '•4, PT 2G.E2• i . 1 > QZ'.0 14" , • c. 0G: •-- .ors' ,-E - � t qv ,e 5..4 Z7.3S Q '.3 LGTH. 7 3 MIN v FTG. I PF .600 Q S$.3 14 .lo TOT. •v> PE - -Q REEMInilli PT 2715 Q .3 (4/ " 122"11111 Z4g PF Z•4$ S8 scr . -0 TOT. PE Q LGTH. PT 30. '3 5.8.3 FTG. PF Q TOT. PE 30.x}' k /0•S-7 Q LGTH. ' • PT 21..g1 r Y FTG. PF .4. Q Zq.D 14 S .4'o TOT. • • .. •048 RE ,5.6. v .4.1 Q 2.'.7! ME FTG. ..��AA�� I PF 21.31 Q S •3 TOT. q.L.- •7A• 7P -- 5".‘419.75 Q 30.4 LGTH. .(. PT V .85 . Q 88.9 IZ4 sca• TOT. ($4- •ZSlo PE •••�© (D.S? 3t.' Q (al.S." 1 LGTH. . ' PT 32.22. 4• .4 2/A-) FTG. L0 I la, PF .Z.S Q ( TOT. I PE .L •S Q LGTH. /0.33 j PT 3s.12- - misi.4 Q (4• • Z N v m TFTOGT. D. Ms P•E F .02 /: ZS 7...5'13:1514- Q I.,5 f. FTG.H. 10.33 11 I'"PT 3 . S j- Q 3oZ.y ZZ TOT. (0.33 V •3°S -PE - i Z•SV40.$' Q [S .g LGTH 0 33 i PT 40.81 N FTG. VS) PF Z.• 0 - 6z•? 3 r-- - TOT. ../1 1------; �� -ZS 43.3c Q (64.5 LGTH.Zo.44. PT 110 24 FTG. PF (. 1 Q 62/.7. 3 j TOT. Zo.(. . •4 0 PE - Q _ LGTH. ;O.ti - -�� PT Sl•'l Jy FTG. PF (,.?.4. Q62-7.2 3t ------ TOT. 31i •101 PE Q LGTH.4I.3Z?��._.._.� PT S1.1-1 y FIG. PF .4.p> 0 GZ7 2 4 - - TOT. • :5Z. 401 PE - -- Q LGTH. Z'S PT w2.'1 of T FTG. ZS P F .O2. 0 Ca1.7 / TOT. 2.1.-S- •0al PE - Q LGTH. 7(0 'T (i3•' - {j'' Z E FTG. 1, P F • 2 Q (0721:1 V TOT, i l2 .0038 PE - Q LGTH. ZZ PT,v •`I g+ w a w a FTG. '.; P r .?. Q G71.1 A. .IS L TOT. 11 .0036 PE Q LGTH. 20 PT 73.11 4 FTG. 0 PF .■ S Q(0 .2 D C- Cr,(O TOT. ' 0 .0°•S •E •- HYDRAULIC CALCULATIONS JOB NO. 5PD -1 DRAWING NO. SHEET NO. Z OF NAME &14,4EPoRI- UW Sr x60170, �_ BY 8. Pi1-i2-se,A1 LOCATION O P lit, t • !b S�ISI"em DATE .r2t9113 .Z9 ' , • .• , /Oo - kilt. ZO • ■S -Cora 4 NOZZLE FLOW FITT G FRICTION HYD. TYPE& IN PIPE i PIPE EQUIV. LOSS REQUIRED REFS PT. ELEV. NOTES LOCATION G,p M, SIZE DEVICES LENGTH P.S.I./FT. P.S.I. a , a F/Ost Q cob ,LGTH. 1. S r PT 74•2. [ Q 1(t7 tact 213. • 0039 PF t-1 s Q LGTH. PL 4L. Q FTG. PF TOT. PE Q LGTH. PT FTG. , P F Q TOT. PE Q LGTH. PT FTG. PF Q TOT. PE Q LGTH. PT Q FIG. PF TOT. PE Q 4 LGTH. PT FTG. _ PF Q TOT. PE Q ,LGTH. 1 PT FTG. PF Q . TOT. -PE Q 1 LGTH. PT FTG. PF Q TOT. PE Q LGTH. PT FTG. PF Q TOT. PE Q LGTH. : PT ' , FIG. ~PF --� Q TOT. PE • Q _LGTH. PT 4. FTG. PF Q TOT. PE Q LGTH. PT FTG. PF Q TOT. i PE Q LGTH. f PT FTG. PF _ Q TOT. PE Q LGTH. PT FTG. _ PF Q TOT. PE Q LGTH. PT ' FTG. PF Q TOT. PE Q LOTH. PT Q FIG. PF TOT. PE Q LOTH. PT FTG. PF Q TOT. PE Q LGTH. PT FTG. PF Q TOT. PE PT I� HYDRAULIC CALCULATIONS JOB NO. _ (3PD- Z DRAWING N0.- - SHEET NO. _ 1 OF _ 4- NAME IM/b4EPOkr ()isTei5u7,, Sysr n *13 _ 'BY & 'C 44-7150A! LOCATION O / etb4• /P /64,21;' 5d-7z'Sbii, . 7764726, ©, DATE /2 /4/ 13 .u!y_im 2Cac�n so.,Fr, 5 . r/41, f NOZZLE FLOAT FITTING FRICTI N HYD. TYPE & IN PIPE A PIPE EQUIV. LOSS REQUIRED REF. PT. ELEV. I N O T E S LOCATION G.P.N. SIZE DEVICES LENGTH P.S.I./FT. P.S.1. a I- Q LGTH. '. ' r_PT /2.5'0 " FTG. PF hit Q IR•i V o . 4 , ,12;1 .33E - C G• ti Q 2p.7 LGTH. '. ' f PT 1111. ,, I N FTG. I PF 1.Z 1 d1 Q 4..c I4 TOT. '•1, ••/74 PE — rf,1rV '¢, 13 Q 11.b LGTH. 4-5 PT 14.13 Q IPZ., I k r FTG. PF J•(,G TOT. j Z..'Z • 131 -PT/4..9 PE --, Q LGTH. .? 02,1 21j Al r FTG. /V PF 2 Q (s2•I TOT. 1a,1, = p37 PE a 31, .`K ' I(r,i3 ° g_ (5:21 Q LGTH. PT 1i.Z7 4,2.1 Q FTG. PF — y Q TOT. PE l?.Zi -_,c • (4.14 Q LGTH. e•(r rPT 12.512 FTG. Q j' IN TOT. `.(y ;, , 1V1 PE — y 40,,I3.12 Q ill LGTH. r•C, PT 13•37. FTG. P Q stO..S I" TOT. •,(,, .48 PE — r 74 1&33 Q ZA,P LGTH. ri, PT I t.33 1. ,1 I H FTG. (P I PF 3,44 Q 6:'4S 14 TOT. !I.' .3 PE — , 15.1144 Q 11,1, LGTH. ;7c PT 21.75 Q 135•1 2-/hI PF ��FTG. TOT. JL PE • S" ,'7S Q LGTH. 117.33 i PT 233 • _ 1354 Q 13 7 !" n? r , . or. /0,•31 .I4.5 -P; 1/10 ' ■7:14 "K'=-21.8 1,74■ Q 140,5 LGTH. 0.33 I PT '6,44 ' Zip OT. _el z.loL '. Q2-164 To T. 1v. ,2�8 Zi. 7Zi Q f 4- LGTH. /0l3 PT 28.Zb di FTG. PF Z O�Q 4��,S 5 TOT. /0,13 .Il Q PE — ('4.54 307 Q ?.."l.Z LGTH.'Woke PT 10,2.5] , Q 6v t, I 3" TOT. 'ZL'• } s 27L RE --7 , Q LGTH. 4 , + PT 3S.15. I w PF Q �nCr 32 TOT. 4 I. , 13� . Sg PE • Q LGTH. ' It PT 41,53 " FTG. •3.t?( Q 506, 4 I TOT. ' . r 074 PE Q LGTH. 'I- PT 44,59 PI FIG. r PF -1.1i Q 50( 7 TOT. `&1 , G�1.5 RE — Q LGTH. . • I PT 0,71 Q 7�le LP, 1F FTG. 21 47-1 PF ,q Tor. V.5 . 01 PE -- Q LGTH. PT 47•411 FTG. PF Q TOT. P E HYDRAULIC CALCULATIONS JOB NO. $p1)" DRAWING NO.- _--- - . SHEET NO. Z OF 4 NAME i 3 i Q I P 4 0/0,l /5 1/2/0 0 1 2.0 A) -- ______ BY BY 8. PE,Q'l2 Sd/.1 LOCATION 0/3P 1D4. 'c S?Sldil 43 DATE X2/4 /13 •20 i 2G0b ,II. • NOZZLE FLOW ITTING FRICTION HYD. PIPE PIPE EQUIV. REQUIRED ELEV. NOTES TYPE SIZE a LENGTH LOSS P.S.I. REF PT. LOCATION N G.P p..M. DEVICES P.S.I./FT. `nl Q LGTH. 20 PT ' . . FTG. •. Q CO& lo CV Our:: o . - - .0 . PF ..�. _ 2a' Q LGTH. PT__5T13 lt FTG. PF 00 Q SO& 'CZ TOT. 2. .OOZ •E . .f Z Q LGTH. 20 PT Q col Z ��TOT. 'P • Oo Z RE I S � 40S Q ‘00 AIi Cr FTG PF Z.00 O p PPF ill 0 =- Q 100 b ^ TOT. 2DO G PE Q LGTH. 1.-9S GOMM 4 FTG. PF . in Q /06'4 loci TOT. Z' Ill •002 PE - Q PT &b. I4 EN F (� AULT PF LCC.4 Q num.TOT. 1 PE Q LGTH. i PT Q FTG. PF TOT. 'E Q LGTH. PT FTG. ! P F Q TOT. PE Q LGTH. � PT FTG. 1 PF Q TOT. PE Q LGTH. i PT FTG. P F Q TOT. PE . Q LGTH. PT FTG. P F Q TOT. Q LGTH. PT FTG. PF Q TOT. PE Q LGTH. i PT FTG. _ PF Q TOT. PE Q LGTH. PT FTG. PF Q TOT. PE Q LGTH. PT FIG. PF Q TOT. PE 11111__ Q FTG.H PF Q TOT. PE Q LGTH. PT • Q FTG. PF • - TOT. PE Q EMI PF Q TOT. PE HYDRAULIC CALCULATIONS JOB NO. _ BPD-3 DRAWING NO._ SHEET NO. 3 OF 4- NAME 6/2ii e/'o,2r I)/ci21$0Tlo i -- --BY 13•744V0A1 LOCATION 06P 81.04. 10 ' T Al 2 ^DATE 12/4/93 ..20 owl 1 / U c-'�C' L4.Fr. 5q 6'c. e. , 21 /j S i o 4 / NOZZLE FLOW PIPE FLING PIPE EQUIV. FRICTION R�UIRED HYD. ELEV. TYPE& IN LOSS REF. p7. LOCATION G.P.M. SIZE DEVICES LENGTH p,S.l./FT. P.S.- Q LGTH. 0. PT fl 5c7 III FTG. €�F i lL Q i.P"�ry f O 41"& 12-7 E ._ G,6.1 r Inv Q W7 LGTH. '•'- _ 1-PT T L.L Q 1 'I FTG. PF 1,7,i . 4c' ' 1 4 TOT. `.4 ,1Z/ PE -- 5,fe/(4, 3 Q 214, LGTH. '.2 - Pr 14..83 Q b .I /-2-,, FTG. L P F 1,73 TOT. 13,25 ' 6' PE -' y Q LGTH. PT 1(,({it la,1 FTG. PF ^ ,/ Q TOT. PE ' V ic,W, r:./S.2l Q LGTH. -. ., PT i2,cca 1,4,1„ Q 1 I©.O I ' TOT. 1.C 427 PE 9,(1J1371 Q 710,7 LGTH. .(i, PT 1* a'Z2 FT . �� PF •�I T i Q dm t TOT. ' •t, 1 e - 7• , is,3Z Q i4,c LGTH. •b t PT 1g,3; i•Q 6.4-C 14 TOT. ' •It�I , ; PE Z.$$ c%4> 21.21 Q 2,5,g LGTH. •4 PT '21.'11• 1 a FTG. PF '3.2,4, i I7 Q tiv, TOT. 12.i, v-Zb PE -- 15.22 24.Q 1 Q '15.3 LGTH. , PT 24.41 Q I ,G 2yl�U TOT. /0,1C ,231 PE 2 b4 131 ,?S Q LGTH. 0.33 ; PT V1.24 ___.0 FTG. _ _PF z.4s Z� z¢ - <- 3 J,'?3 is _ Q l bs.l j e i TOT. /0,33 �3 l PE — . 31.73( z9.49 Q MI LGTH. .,'3' _ PT Si.bq i FTG. PF 3.gs Q 3324; Ls' TOT. /0,3T-74 37(, pe_ 31.13 ?;.c7 Q Ifq.iv LGTH. W4&, PT 33,0 , Q 7Z�•1 3 ' FTG. PF 6,44, —. TOT. IV.id, t , LIP? PE Q LGTH. a PT 3'03 , 14 FTG. ,,, 4;,07 2 Q ., 32 TOT. 1.33 r 14 PE Q LGTH. 41.33 PT 45,to Q ,.1 4-4 TpT;�T , `�t PE 31 _. Q LGTH. 0 PT 4141 1 _ 4 FTG. 11- , PF 3. 33 511.Q � • 1 '7 TOT. 141., .027 RE Q LGTH. i U PT 171..q4' �! se FTG. 3 PF ,`3v Qc7 •I TOT. 112- ,0027 PE — Q LGTH. 2'2, PT 53,Z4 ___i Q giS,I bf 1 VA,i:1S°ER TOT. '11 ,0/727 PE �5� ._... 1 3 Z2` • Q LGTH. PT c/l•`;iii, FTG. PF Q TOT. P E HYDRAULIC CALCULATIONS • JOB NO. 5P,p "3 DRAWING NO. SHEET NO. 4- OF 4- NAME lie 1 D4C,102 f iS/E/$ r7o4 _BY a•776 sore LOCATION )B/ &isv. 1!o ��sfl iZ DATE V4-113 zo G ��, �•tea �.F� NOZZLE FLOW FITTING FRICTION HYD. TYPE& IN PIPE & PIPE EQUIV. LOSS REQUIRED REF PT. ELEV. N 0 T E S LOCATION G.P.M. SIZE DEVICES LENGTH P.S.1./FT. P.S.I. Q LGTH. 2.133 _ PT 62.'76. Q S$$ 8`c2 6'T FTG.`TOT. `w— •004 -PE -'� OJE Q C__. _ LGTH. tct P7 3. ( �lJ y FTG. P F Q IOU Icier ^TOT. vtg . 002. RE - Q LGTH. PT (05.13 a v.4ar Q FTG. PF — Co Cho/41 TOT. PE Q LGTH. PT FIG. PF Q TOT. PE Q LGTH. PT FTG. PF Q TOT. PE Q LGTH. PT FTG. _ PF Q TOT. PE _... Q LGTH. PT FTG. PF Q _TOT. -PE Q LGTH. PT FIG. PF • Q TOT. PE Q LGTH. PT FTG. j PF Q TOT. PE Q LGTH. LPT FTG. Pr Q TOT. PE Q LGTH. PT FTG. Pr Q TOT. PE Q LGTH. PT FTG. PF Q TOT. PE , Q _ LGTH. PT FTG. 1 PF Q TOT. PE 1 Q LGTH. PT FTG. PF Q TOT. PE Q LGTH. PT FTG. PF Q TOT. PE Q LGTH. PT FTG. PF Q TOT. PE . Q LGTH. PT FTG. PF Q TOT. PE Q LGTH. PT FTG. PF Q TOT. -PE — , PT G.P.M. MULTIPLY SCALE BY 1-0V 1 2 ! 8 9 10 11 12 � 13 14 15 lifll !!il11lmmultrammisi _ _ . •I■o■■■■■■■■--1■.---i6w■.i�- ��■■T■w■■._.■-t■■ / j'}-y. 1 - ■IIII■■■I■■■■..---.----�---- �t�— (N /�,r ��/�'s` sr�c . 11 ■■■ ■■■■ .■1-11._ _-1- --- -�Qi-�-9ZPSi Res• ``?Ne+6MI ■ 111■■■■■■■.■.--..-�- oomMis o _ — aIIIIIIliiiill�lili!l�1aaa� .111.............._.__----_ iiiiii ofonnummsom•m iiiiti�ii-----,II nu■■■■■■■■-■■.11-1■■ .1111.....■■.....ENE SYSj'. DE,n4A40 FORM 111 4L(< s"-'I"%4F Alec �— ..... _ — r111 ■■■■■■■■■■�MEM ...�.i , ( 1 11 /1 ■■■rte■■ rw�wl■■1�■t■ _ - . IIIIHNII:::111rIO ad «2741"Q 7 411S4 VI'n -------- --- , aIl1i !liI,iiii!il !liiIili !■ 111111111 ■It 1■■li■■■■ .. =C-ni--_�-1tt■w■-�wwtw-r�■ O ::1� 11■I't:•::=:mim--= i==:—mi-- ■..._.. --,—_ ; ■I� ��I�■=■:■■111.1 wg■r■■ --■■l-ww- -■-i -■---1■■ Ii ................. .. . ......1....■ .1■■t.�111 r■--- _":--_-----.—.—I 1 • t0 III ■_■u'■i■ :--i--i-.. moiler! -------. _::_. __=-.Y.:..*----•- _ - ss ■■■. ■: .. _�..-. _ --aaa_ !Wink Alm•Raillem... 11 1 11111 ■■■111 .m -- -- .1-__-:.:-:777.: _.–_. , • X11■■■■..■._ : S 0 ,,,1111111111:11ritritiall ICIZt 4PA1 e 417 AS 1 -21 ... . i Hai:1M liONZ= 1 -:--.7 77:- -::: a r ._.. Y 11Se..1a11i111111_ w i t r I6 30 UW { .2,‘[ t, fps 203- COt 19 RECEIVED Worldwide tqco www.tyco-fire.com DEC 1 2013 Contacts CITY TIGARn BUILD Series TY-B — 2.8, 5.6, anc� .u -Q�actor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General be consulted with respect to the suit- ' ability of these coatings for any given �-- Description corrosive environment.The effects of n "`ambient temperature,concentration of The TYCO Series TY-B, 2.8, 5.6, and chemicals,and gas/chemical velocity, 8.0 K-factor, Upright and Pendent should be considered, as a minimum, Sprinklers described in this data sheet along with the corrosive nature of the are standard response - standard chemical to which the sprinklers will be r coverage,decorative 5 mm glass bulb exposed. type spray sprinklers designed for use An intermediate level version of the ' - in light, ordinary,or extra hazard,corn- Series TY-B Pendent Sprinkler can be �' '^' mercial occupancies such as banks, obtained by utilizing the Series TY-B Viiiirdalb hotels, shopping malls, factories, Pendent Sprinkler in combination with refineries,and chemical plants. the Model S2 Shield. The recessed version of the Series ,,,„drommouft` TY-B Pendent Sprinkler, where appli- NOTICE cable, is intended for use in areas with The TYCO Series TY-B Sprinklers ,;,.;4K a finished ceiling. It uses a two-piece described herein must be installed r' Style 10(1/2 inch NPT)or Style 40(3/4 and maintained in compliance with . inch NPT)Recessed Escutcheon.The this document, as well as with the Recessed Escutcheon provides 1/2 applicable standards of the National inch(12,7 mm)of recessed adjustment Fire Protection Association, in addition 1 or up to 3/4 inch (19,1 mm) of total to the standards of any other authori adjustment from the flush pendent ties having jurisdiction. Failure to do so ' fJ position.The adjustment provided by may impair the performance of these r, the Recessed Escutcheon reduces the devices. "' f�' accuracy to which the fixed pipe drops ''' to the sprinklers must be cut. The owner is responsible for maintain- ing their fire protection system and Corrosion resistant coatings, where devices in proper operating condition. applicable, are utilized to extend the The installing contractor or sprinkler life of copper alloy sprinklers beyond manufacturer should be contacted with that which would otherwise be obtained any questions. when exposed to corrosive atmo- spheres.Although corrosion resistant coated sprinklers have passed the Sprinkler standard corrosion tests of the appli- cable approval agencies, the testing identification is not representative of all possible corrosive atmospheres. Consequently, Numbers it is recommended that the end user TY1151 Upright 2.6K, 1/2"NPT TY1251 . . . . Pendent 2.8K, 1/2""NPT TY3151 Upright 5.6K, 1/2"NPT IMPORTANT TY3251 . . . . Pendent 5.6K,1/2-NPT Always refer to Technical Data TY4151 Upright 8.0K,3/4"NPT "' - Sheet TFP700 for the "INSTALLER TY4251 . . . . Pendent 8.0K, 3/4 NPT WARNING" that provides cautions TY4851 Upright 8.0K, 1/2-NPT with respect to handling and TY4951 . . . . Pendent 8.0K, 1/2""NPT installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 MARCH 2013 TFP151 t tf TFP151 " Page 2 of 8 . CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 7 3 - Sealing 6- Deflector* r„-,-----;-,,t Assembly 7 - Bushing r .--r-- T 1 4 - Bulb_______ (11/1mm) 2-1/4" � a, 3•' NOMINAL (57,2 mm) "., 111_ — MAKE IN ` + 2 *Temperature rating is 111 II r�r 2-3/16" I 1-9/16" 4 indicated on Deflector. (55,6 mm) (39,7 mm) I ° 5 ** Pipe thread connections \ /Pl!ti\\ r ,�g��", 6* per ISO 7-1 can be provided on special 1/2"NPT** t WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT(TY1151)AND PENDENT(TY1251)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression - is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE . Ti 'L 1 7116" . -' � 3 _________- 1 / m,_-.=-_-(11,1 mm) NOMINAL o/- -2 3/16MAKE-IN (55,6 mm) `-- 4 — 2-3/16" 1-1/2" (55,6 mm) I (38,1 mm) C— 5 - \ _ AA+ j 6* 1/2"NPT** I WRENCH STYLE 10 Imo—2-7/8'(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 SERIES TY-B UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE r Ri TFP151 " Page 3 of 8 . *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE I' Air- 1/2' Or/• (12,7 mm) 1 3 I / n NOMINAL } 2-5/16" A 2 MAKE IN (58,7 mm) ` — r 2 1/4" 4 1-9/16" I (57,2mm) (39,7 mm) _ . —�5 3/4"NPT** t WRENCH STYLE 40 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 SERIES TY-B UPRIGHT(TY4151)AND PENDENT(TY4251)SPRINKLERS 8.0 K-FACTOR,3/4 INCH NPT, STANDARD RESPONSE CEILING PLATE 1 - Frame 5 - Compression - SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector* I r � � ; 1 4 ie Assembly 7 F 3 4 - Bulb ' 7/16" 2-1/4" (11,1 mm) (57,2 mm) % !J 2 NOMINAL - MAKE-IN *Temperature rating is 1 II I 2-3/16" I 1-9/16" 4 indicated on Deflector. + (55,6 mm) I (39,7 mm) _ . I ��5 ** Pipe thread connections \ -- -- 1I —�i+�" 6* per ISO 7-1 can be provided on special 1/2"NPT** f WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE c TFP151 Page 4 of 8 SPRINKLER FINISH(See Note 8) K TYPE TEMP. BULB LIOUID NATURAL CHROME WHITE*** LEAD WAX WAX OVER BRASS PLATED POLYESTER COATED COATED LEAD COATED 135°F(57`C) Orange UPRIGHT 155`F(68`C) Red 2.8 (Tand 1) 175`F(79`C) Yellow 1.2,3 1/2" PENDENT N/A NPT (TY1251) 200°F(93°C) Green Figure 1 286T(141°C) Blue 360`F(182"C) Mauve 1,2 135°F(57`C) Orange UPRIGHT 155`F(68`C) Red (Tand i) 175°F(79°C) Yellow 1,2,3,5 1,2,3,5 PENDENT 1,2,3,4,5,6,7 1,2,3,5 (TY3251) 200°F(93°C) Green 5.6 Figure 2 286°F(141°C) Blue 1/2" 360`F(182°C) Mauve N/A NPT 135°F(57`C) Orange RECESSED 155`F(68"C) Red PENDENT 1,2,3,4,5 (TY3251)* 175`F(79`C) Yellow N/A Figure 5 200°F(93`C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange UPRIGHT 155`F(68"C) Red 1,2,3,5 1.2.5 (TY4151)1) 175`F(79`C) Yellow PENDENT 200°F(93°C) Green 1,2,3,4,5,6,7 1,2,5 (TY4251) _ Figure 3 286°F(141°C) Blue 8.0 3/4' 360°F(182°C) Mauve N/A NPT — 135°F(57`C) Orange RECESSED 155`F(68`C) Red PENDENT 1,2,3,4,5 (TY4251)* 175`F(79`C) Yellow N/A Figure 6 200°F(93`C) Green 286°F(141°C) Blue 1,2 135'F(57°C) Orange UPRIGHT 155`F(68`C) Red 8.0 ( and 1) 175°F(79`C) Yellow 1/2 PENDENT 200°F(93°C) 1,2,3,4,5,6 N/A NPT (TY4951) 93°C) Green Figure 4 286°F(141°C) Blue 360`F(182°C) Mauve NOTES 1. Listed by Underwriters Laboratories,Inc.(UL) 2. Listed by Underwriters Laboratories,Inc.for use In Canada(C-UL) 3. Approved by Factory Mutual Research Corporation{FM) 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03) 5. Approved by the City of New York under MEA 354-01-E 6. VdS Approved(For details contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 8. Where Polyester Coated,Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax over Lead Coated Sprinklers are noted to be FM Ap- proved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. ' Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon.as applicable 150°F(66-C)Maximum Ceiling Temperature Frame and deflector only.Listings and approvals apply to color(Special Order) TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS • TFP151 Page 5 of 8 SPRINKLER FINISH K TYPE - NATURAL CHROME WHITE LEAD WAX WAX OVER LEAD BRASS PLATED POLYESTER COATED COATED COATED 2.8 UPRIGHT(TY1151) 1/2" and 175 PSI(12,1 BAR) N/A NPT PENDENT(TY1251) UPRIGHT(TY3151) and 175 PSI(12,1 BAR) 5.6 PENDENT(TY3251) 250 PSI(17,2 BAR) 1/2"" OR NPT 175 PSI(12,1 BAR) RECESSED PENDENT (SEE NOTE 1) (TY3251) N/A UPRIGHT(TY4151) and 175 PSI(12,1 BAR) 8.0 PENDENT(TY4251) 3/4" NPT RECESSED PENDENT 175 PSI(12,1 BAR) N/A (TY4251) 8.0 UPRIGHT(TY4851) 1/2" and 175 PSI(12,1 BAR) NPT PENDENT(TY4951) NOTE 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York TABLE B SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE Technical Physical Characteristics Design Frame Bronze Data Button Brass/Copper Criteria Sealing Assembly.. . Beryllium Nickel Approvals w/TEFLON The TYCO Series TY-B, 2.8, 5.6, UL and C-UL Listed Bulb Glass and 8.0 K-factor, Upright and Pen- FM, LPCB, VdS, and NYC Approved Compression Screw Bronze dent Sprinklers are intended for (Refer to Table A for complete approval Deflector Copper fire protection systems designed information including corrosion resis- Bushing(K=2.8) Bronze in accordance with the standard tant status.) installation rules recognized by the applicable Listing or Approval Maximum Working Pressure Operation agency (for example, UL Listing is Refer to Table B The glass bulb contains a fluid which based on the requirements of NFPA g 13, and FM Approval is based on the Discharge Coefficient expands when exposed to heat.When requirements of the FM Loss Prevention K = 2.8 GPM/psiv2 (40,3 LPM/bar"2) the rated temperature is reached, the Data Sheets). Only the Style 10 or 40 K = 5.6 GPM/psiv2 (80,6 LPM/bar112) fluid expands sufficiently to shatter the Recessed Escutcheon, as applicable, K = 8.0 GPM/psi1/2(115,2 LPM/bar"2) glass bulb, allowing the sprinkler to is to be used for recessed pendent activate and water to flow. installations. Temperature Ratings Refer to Table A Finishes Sprinkler:Refer to Table A Recessed Escutcheon:Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass • r:. TFP151 Page 6 of 8 2-7/8"DIA. Gl 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) - (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) /' RENCH W RECESS FACE OF (57,2 mm) MOUNTING (E 1/2"NPT MODELS) SPRINKLER PLATE FITTING ... / 1/8° (3,2 mm) WRENCH RECESS —1 t' I (END"B"USED FOR j r$111 j I 3/4" NPT MODELS) -J 1 FIGURE 7 t� MOUNTING W-TYPE 6 SURFACE ,� SPRINKLER WRENCH CLOSURE SERIES 1-1/4'(31,8 mm) TY-B 3/4°(19,1 mm) WRENCH RECESS FIGURE 5 �,yr SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY /i WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8"DIA. (73,0 mm) 3/4"(19,1 mm) \� 5/8±1/4" PUSH WRENCH - (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) • INTO ENSURE FACE OF (57,2 mm) MOUNTING ENGAGEMENT SPRINKLER PLATE WITH SPRINKLER FITTING WRENCHING CHHININ AREA AREA / 1/8" FIGURE 8 r (3,2 mm) W-TYPE 7 RECESSED I SPRINKLER WRENCH r w�� f Installation MOUNTING . I The TYCO Series TY-B, 2.8, 5.6, and SURFACE ------ 8.0 K-factor, Upright and Pendent CLOSURE SERIES 1-5/16"(33,3 mm) Sprinklers must be installed in accor- TY B 13/16'(20,6 mm) dance with this section. NOTICE FIGURE 6 Do not install any bulb type sprinkler if SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY the bulb is cracked or there is a loss of WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT liquid from the bulb. With the sprinkler STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT held horizontally, a small air bubble should be present.The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F(57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Obtain a leak-tight 3/4 inch NPT sprinkler joint by applying a minimum to maximum torque of 10 to 20 ft-lbs. (13,4 to 26,8 Nm).Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. 1 IS TFP151 Page 7 of 8 Do not attempt to make-up for insuf- Recessed Pendent Sprinklers replaced. Also, replace any sprinkler ficient adjustment in the escutcheon The Series TY-B Recessed Pendent that has a cracked bulb or that has lost plate by under- or over-tightening the Sprinklers must be installed in accor- liquid from its bulb. (Ref. Installation sprinkler. Readjust the position of the dance with the following instructions. Section.) sprinkler fitting to suit. Step A. After installing the Style 10 The owner is responsible for the Upright and Pendent Sprinklers or 40 Mounting Plate, as applicable, inspection,testing,and maintenance of The Series TY-B Upright and Pendent over the sprinkler threads and with their fire protection system and devices Sprinklers must be installed in accor- pipe-thread sealant applied to the pipe in compliance with this document, as dance with the following instructions. threads,hand-tighten the sprinkler into well as with the applicable standards of the sprinkler fitting. the National Fire Protection Association Step 1. Install pendent sprinklers in (for example, NFPA 25), in addition to the pendent position; install upright Step B.Tighten the sprinkler into the the standards of any other authorities sprinklers in the upright position. sprinkler fitting using only the W-Type having jurisdiction. Contact the install- 7 Recessed Sprinkler Wrench (Figure in contractor or sprinkler manufacturer Step 2. With pipe-thread sealant 8).With reference to Figure 3 or 4,the ing p applied to the pipe threads, hand- W-Type 7 Recessed Sprinkler Wrench regarding any questions. tighten the sprinkler into the sprinkler to the sprinkler wrench flats. Automatic sprinklers are recommended fitting. to be inspected,tested,and maintained Step C.After the ceiling is installed or by a qualified Inspection Service in Step 3. Tighten the sprinkler into the the finish coat is applied, slide on the y q p sprinkler fitting using only the W-Type Style 10 or 40 Closure over the Series accordance with local requirements 6 Sprinkler Wrench (Figure 7). For TY-B Sprinkler and push the Closure and/or national codes. wax-coated sprinklers, use an 8 or over the Mounting Plate until its flange 10 inch adjustable Crescent wrench. contacts the ceiling. With reference to Figures 1 through 4, apply the W-Type 7 Sprinkler Wrench Care and or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. Mai � /� ntenance When installing wax-coated sprinklers The TYCO Series TY-B, 2.8, 5.6, and with the adjustable Crescent wrench, 8.0 K-factor, Upright and Pendent exercise care to prevent damage to the Sprinklers must be maintained and ser- wax coating on the sprinkler wrench viced in accordance with this section. flats or frame arms and,consequently, exposure of bare metal to the corrosive Before closing a fire protection system environment. Open the jaws of the main control valve for maintenance wrench sufficiently wide to pass over work on the fire protection system the wrench flats without damaging the that it controls, obtain permission to wax coating. Before wrench tightening shut down the affected fire protection the sprinkler, adjust the jaws of the system from the proper authorities wrench to contact only the sprinkler and notify all personnel who may be wrench flats. After wrench tightening affected by this action. the sprinkler, loosen the wrench jaws Owners must ensure that sprinklers before removing the wrench. are not used for hanging any objects. After installation, inspect the sprinkler Otherwise, non-operation in the event wrench flats and frame arms and of a fire or inadvertent operation may retouch(repair)the wax coating when- result. ever the coating has been damaged Absence of an escutcheon, which is and bare metal is exposed. Retouch used to cover a clearance, may delay the wax coating on the wrench flats the time to sprinkler operation in a fire by gently applying a heated 1/8 inch situation. diameter steel rod to the damaged areas of wax, to smooth it back over Sprinklers which are found to be leak- areas where bare metal is exposed. ing or exhibiting visible signs of corro- sion must be replaced. NOTICE Automatic sprinklers must never be Only retouching of the wax coating painted, plated, coated, or otherwise applied to the wrench flats and frame altered after leaving the factory. arms is permitted, and the retouching Modified sprinklers must be replaced. is to be performed only at the time of Sprinklers that have been exposed to the initial sprinkler installation. corrosive products of combustion, but have not operated, should be replaced The steel rod should be heated only to if they cannot be completely cleaned - the point at which it can begin to melt by wiping the sprinkler with a cloth or the wax, and appropriate precautions by brushing it with a soft bristle brush. need to be taken when handling the heated rod in order to prevent the Care must be exercised to avoid dam- installer from being burned. age to the sprinklers before, during, and after installation.Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be • • TFP151 Page 8 of 8 P/N 57 - XXX - X - XXX I I SIN SPRINKLER TEMPERATURE FINISH RATINGS 530 2.8K UPRIGHT(1/2"NPT) TY1151 1 NATURAL BRASS 135 135°F(57°C) 531 2.8K PENDENT(1/2"NPT) TY1251 3 PURE WHITE(RAL9010)' 155 155°F(68°C) 570 5.6K UPRIGHT(1/2"NPT) TY3151 4 SIGNAL WHITE(RAL9003) 175 175°F(79°C) 571 5.6K PENDENT(1/2-NPT) TY3251 X JET BLACK(RAL9005)`° 200 200°F(93°C) 590 8.0K UPRIGHT(3/4"NPT) TY4151 6 WAX COATED 286 286°F(141°C) 286°F(141`C)MAX 591 8.0K PENDENT(3/4"NPT) TY4251 7 LEAD COATED 360 360`F(182°C) 560 8.0K UPRIGHT(1/2"NPT) TY4851 8 WAX OVER LEAD 286°F 286°F(141°C)MAX 561 8.0K PENDENT(1/2"NPT) TY4951 9 CHROME PLATED •Eastern Hemisphere sales only. • **Available in only 8.0K,155°F(68°C) or 200°F(93°C);requires lead time to manufacture. TABLE C SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating,P/N(Refer to Table C). Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with(specify)finish,P/N*. •Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. GLOBAL HEADQUARTERS 1400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700 Copyright 0 2013 Tyco Fire Products,LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. 0 2 ., ,- TOLD:3 www.toice.com NIBCC1 Revision 12/10/2007 - Fig. 2 — Adjustable Band Hanger C 0 US LISTED Fig. 2NFPA — Adjustable Band Hanger with Reduced Rod Size Range — Size 21/2" thru 6" pipe. fa, Material — Carbon Steel, Pre-Galvanized .---1,. Function — Recommended for the suspension of non-insulated pipe or / / insulated pipe with Fig. 220 shield. 1- 1 Fig. 2NFPA accommodates the reduced rod schedule of the National Fire / \ \\ ), Protection Association Pamphlet 13. . Approvals — Factory Mutual Engineering approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-171 E, i 1 / .''\ Type 10 and Manufacturers Standardization Society SP-69, Type 10. B ' / Finish — Pre-Galvanized 1/ j,/ Note — Available in Stainless Steel materials. .,,. Order By — Figure number, pipe size and material A :. / . ?// Dimensions •Weights Pipe Max.Rec. Approx WtJ100 Size Rod Size A B C Load Lbs. Fig.2 Fig.2NFPA 21/2 1/2* 53/4 41/4 15/8 600 41 40 3 1/2* 6 41/8 11 600 45 43 31/2 1/2* 73/8 51/4 21/8 600 52 50 4 5/8` 73/8 5 15/8 1000 59 56 5 5/8" 9 61/8 24 1250 97 95 6 3/4" 93/8 61/2 17/Et 1250 139 105 3/8" nut is used when NFPA rod sizing is requested. " 1/2" nut is used when NFPA rod sizing is requested. OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•COHONA,CA 92873•PH: 951.737.5599•FAX. 951.737.0330 8 CUSTOMER SERVICE•800.786.5266 www.tolco.com 142:4 Z'OLCO www.tolco.com . NIBCO. Revision 9/1/2006 Fig. 2F - Adjustable Band Hanger with Felt Lining c 0 US LISTED Size Range— 1/2" thru 6" copper tubing Material —Carbon Steel, Pre-Galvanized Function — Recommended for the suspension of copper tube so c as to prevent electrolysis. The felt lining also acts to reduce noise in i copper or other pipe types. 1 Approvals—Underwriters'Laboratories Listed in the USA(UL) and ! Canada (cUL). Conforms to Federal Specification WW-H-171 E,Type 10 and Manufacturers ` ;, Standardization Society SP-69, Type 10. B ') Finish— Pre-Galvanized +; , !,' Note—When used for steel or other pipe types, consult factory , , /,. for proper size. Available in Stainless Steel materials. A , ,-i/ ,/! Order By— Figure number and copper tube size .h,, '+1 tz T Dimensions •Weights Copper Tube Max. Rec. Approx. Size Rod Size A B C Load Lbs. WtJ100 1/2 3/8 3'/e 25/8 13/8 400 12 3/4 3/8 3'/8 2b 1'/8 400 12 1 3/8 33/8 25/8 1 1/8 400 13 1 1/4 3/8 33/4 27/a 1'/4 400 14 1'/2 3/8 37/8 27/8 1 1/8 400 15 2 3/8 41/4 3 1 400 16 2'h' 1/2 53/4 41/8 13/4 600 41 3* 1/2 6 4 1'h 600 46 31/2" 1/2 73/8 51/4 13/8 600 53 4` 5/8 73/8 5 17/8 1000 60 5** 5/8 9 611e 21h 1250 98 6"' 3/4 93/8 61/2 21/4 1250 140 3/8" nut is used when requested. "` 1/2" nut is used when requested. OFFICE/MANUFACTURING FACILITY•1275 SAMPSON AVE.•CORONA,CA 92879•PH: 3^1.737.5599•I AX 95'.737.0330 CUSTOMER SERVICE•800.786.526E III www.tolco.com 0 .: TOLCO www.tolco.com NIBCO' Revision 3/1/2007 Component of State of California OSHPD Approved • Fig. 2WON - Adjustable Band Hanger w/o Swivel Nut Seismic Restraints System Fig. 2FWON - Felt Lined Band Hanger w/o Swivel Nut COOS` O Size Range— (Fig.2WON) Size 2" thru 8" pipe. A (Fig.2F WON) 1/2" thru 8" copper tube E I Material — Pre-Galvanized Steel - j) ,, . Function— Recommended for the suspension of non-insulated D pipe or insulated pipe with Fig.220 shield. Approvals— Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Conforms to Federal Specification WW-H-171 E, Type 7, and Manufacturers Standardization Society SP-69, Type / 01'-g 7, 3/4" thru 6". Figure 2WON is included in our Seismic Restraints catalog approved by the state of California. c Finish— Pre-Galvanized Note—Available in Stainless Steel materials. B Order By—Figure number and pipe size �. y Fig. 2WON• . i, 7. . j �`. �: i - :1 \ I # f .... i! - h :� Fig• . 2F WON g Dimensions •Weights Pipe Rod Size Max.Rec. Approx. Size A B c D Load Lbs. WtJ100 1/2 3/8 25/8 2'/e 11/4 400 14 3/4 3/8 25/8 2 1 400 14 1 3/8 27/8 21/a 1 400 16 11/4 3/8 33/s 21/2 11/4 400 17 1 1 3/8 31/2 21/2 1 400 18 2 3/8 33/4 21/2 7/8 400 20 21/2 1/2* 5 31/2 11 600 27 3 1/2" 51/2 35/e 1 1/4 600 40 31/2 1/2" 63/4 45/8 2 600 48 4 5/8* 6'/4 45/8 112 1000 53 5 5/8" 81/2 55/8 21/8 1250 91 6 3/4" 91/4 57/8 15/8 1250 99 8 3/4"" 12!/4 77/e 25/e 1250 120 " 3/8" nut is used when NFPA rod sizing is requested. "' 1/2"nut is used when NFPA rod sizing is requested. ® OFFICE/MANUFACTURING FACILITY•1275 SAMPSGN A.VL.•;ORONA,CA 92879•PH: 951.737.5599•FAX 951.737.0333 CUSTOMER SERVICE•800.786.5266 www.toico.com i 'D LCD www.toico.com a row rn MAO' Revision 9/1/2006 Component of State of Fig. 3 - J-Hanger for Pipe or Conduit California OSHPD Approved Fig. 3F - Felt Lined J-Hanger for Copper Tubing Seismic Restraints System Fig. 3PVC - PVC Coated J-Hanger for Pipe or Conduit Size Range— 1/2" thru 12" pipe size Material —Carbon Steel A Function — Recommended for the suspension of non-insulated pipe, or /t insulated pipe with Fig.220 shield. Side hole allows for wall mounting. LE4 . c Fig. 3F and Fig.3PVC are designed to reduce noise and vibration and/or /' i '' y prevent electrolysis between pipe and hanger. �' =o ` Approvals—Conforms to Manufacturers Standardization Society SP- / n a1n 69,Type 5. Included in our Seismic Restraints Catalog approved by the i - State of California Office of Statewide Health Planning and Development a Fy (OSHPD). For additional load. spacing and placement information relating F — % to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems B Guidelines. Finish— Electro-Galvanized Note—Available in HDG finish or Stainless Steel materials. Fig. 3 Order By— Figure number, pipe size and finish tai L ' f! i-. \ © � y ; I - i ' . i /r •�� / Fig. 3F Fig. 3PVC Dimensions •Weights Copper Tube Rod Size Max.Rec. Approx. Size A B C D E F Load Lbs. Wt./100 1/2 3/8 2% 134 7/16 11/2 115/is 400 18 3/4 3/8 21/2 11/2 7/16 111/16 21/8 400 21 1 3/8 215/i6 115;le 7/16 113hs 2 5/ts 400 22 11:4 3/8 31/4 2 7/16 21/is 2% 400 25 11/2 3/8 33'l6 24/16 7/16 27/is 21/2 400 27 2 3/8 3"/ie 21/2 7/16 29/,6 31/16 400 29 21/2 1/2 47/1c 27/1e 9/16 34'16 35e 500 64 3 1/2 413/16 2t% 9/16 31 41'16 500 72 3-1/2 1/2 51/2 2% 9/16 34/4 4% 500 84 4 5/8 61/2 Vit. 9/16 4% 54/is 550 138 5 5/8 63/4 3'4 9/16 51/16 534 550 162 6 3/4 73'4 3y'I6 9/16 513he 658 600 249 8 7/8 93'ic 315 is 9/16 615hs 8 760 291 10 7/8 103'4 Ks 9/16 7% 91s 760 315 OFFICE/MANUFACTURING FACILITY•1:75 SAMPSON AVL.•CO-IONA.CA 92879•PH. 951.737.5599•FAX 951.737.0330 CUSTOMER SERVICE•800.706.5265 II wwwto/co.com (1) To Loa www.toico.com 111�BC0' Revision 3/7/2007 Fig. 4 - Standard Pipe Clamp Cal omao OSHPD Approved c011$LISTED Fig. 4F - Standard Pipe Clamp Felt Lined Seismic Restraints System Fig. 4PVC - Standard Pipe Clamp PVC Coated Size Range— (Fig.4) Size 1/2"thru 30" pipe. . B I Size Range— (Fig.4F) Size 1/2" thru 2?/2" copper tubing . .. Material —Carbon Steel - Function —Recommended for the suspension of non-insulated pipe or insulated pipe with , Fig.220 shields. (Use Fig.330 Weldless Eye Nut, Fig. 102 Eye Rod or Fig. 101 Welded Eye A Rod.) Also recommended for attachment of sway bracing up to 31/2" pipe size, for larger pipe sizes use Fig.4A. Fig.4F and Fig.4PVC are designed to reduce noise and vibration , and/or prevent electrolysis. Approvals— Underwriters'Laboratories Listed in the USA(UL), Canada(cUL) 1/2" - 8", , , and approved by Factory Mutual Engineering, 3/4" - 8". Federal Specification WW-H-171 E, I • Type 4, 11/2"thru 24" and Manufacturers Standardization Society SP-69,Type 4. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide r Health Planning and Development(OSHPD). For additional load. spac- Fig. 4 ing and placement information relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines, Note—When the Fig.4 is used as a sway brace,to ensure perfor- mance, the UL Listing requires that it must be used with other TOLCO® brace products. • • Maximum Temperature—750`F Finish— Plain t4) Note—Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By— Figure number, pipe size and finish. Fig. 4F Order Note—When ordering Fig.4F allow for 3/16" felt on each half of clamp. Fig. 4PVC Dimensions •Weights Max.Design Load Lbs. Pipe For Service Temp. Approx. Size A B C D Bolt Size 650` 750`F Wt./100 1/2 37/16 1/4 11/s 1% 5/16 500 445 29 3/4 39/16 1/4 11/4 11/4 5/16 500 445 31 1 39/e 1/4 11/4 15/16 5/16 500 445 35 11/4 4356 3/8 1% 111/46 5/16 500 445 40 11/2 49/16 3/8 1% 17/s 5/16 800 715 42 2" 59/16 3/8 2 21/4 3/8 1040 930 93 21" 67/ie 3/8 21/2 23/4 1/2 1040 930 126 3" 7 3/8 23/4 31/46 1/2 1040 930 141 31:2" 711/m 3/8 31/s 3% 1/2 1040 930 154 4 81 5/8 35x6 31t/is 1/2 1040 930 229 5 9% 3/4 37/s 4% 5/8 1040 930 261 6 11% 3/4 41/2 51:/s 3/4 1615 1440 537 8 135/16 1 53 6 3/4 1615 1440 625 10 161/2 1 71/4 71/4 7/8 2490 2220 1378 12 181/2 1 81/4 81/4 7/8 2490 2220 1574 14 20 1% 9 9 7/8 2490 2220 2103 16 23 1% 101/4 101/4 7/8 2490 2220 2314 18 251/2 11/4 111 111 1 3060 2730 3276 20 28 1% 121/2 121/2 11/4 3060 2730 3863 24 331 1% 151/4 151/4 11/4 3060 2730 5222 30 41% 2 19 19 13/4 3500 3360 10511 "Meets UL 203A requirements for attachment of sway bracing. Horizontal design load for 112"-2"-360#,212"-3954,3"-435#,31/2"-5404 ® OFFICE/MANUFACTURING FACIUTY•;75 SAM'S(N AVE.•0O9ONA.CA 92879•Ph 951.737.5599•FAA 951.;37.0330 CUSTOMER SERVICE•800.786.5266 www.toko.com T O L C O www.tolco.corn NIBCO Revision 3/1/2008 Fig. 4A - Pipe Clamp for Sway Bracing Cornia OSlot State of C u� US LISTED California OSHPD Approved Seismic Restraints System Size Range—4" thru 8" pipe. For sizes smaller than 4" use TOLCO®Fig.4. t3 Material —Carbon Steel i Function — For bracing pipe against sway and seismic disturbance. _ . j Approvals— Underwriters' Laboratories Listed in the USA (UL) and Canada , (cUL) 4" thru 8". Included in our Seismic Restraints Catalog approved by / AS I the State of California Office of Statewide Health Planning and Development (OSHPD). i Installation Instructions—The Fig.4A is the "braced pipe" attachment --� i A . component of a longitudinal, lateral or riser brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO transitional and structural - attachment component(s) to form a complete bracing assembly. NFPA 13 0 - and/or OSHPD guidelines should be followed. To Install— Place the Fig.4A over the pipe to be braced. Attach TOLCO transitional fitting, either Fig.980, 910 or 909,to the clamp ears. Tighten bolts and nuts;torque requirement is a minimum of 50 ft. lbs. Transitional fitting � attachment can pivot for adjustment to proper brace angle. C Finish— Plain Note—Available in Electro-Galvanized and HDG finish or Stainless Steel materials. - Order By— Figure number, pipe size and finish e Fig. 4A - Longitudinal Brace TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCOf)brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER—NIBCO does NOT warrant against the failure of TOLCO®brand bracing components,in the instance that such TOLCO'brand bracing components are used in combination with products,parts or systems which are not manufactured or sold under the TOLCO®brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect. incidental or consequential damages of any kind, including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been.or are used. Dimensions •Weights Pipe Max.Horizontal Approx. • Sizes A B C D Bolt Size Design Load Wt./100 4 81 9/16 338 3'1/le 1/2 2015 221 5 93/4 9/16 37/8 43/8 1/2 2015 253 6 111/2 5/8 5 51/2 1/2 2015 513 8 131/4 3/4 61116 61/s 1/2 2015 601 OFFICE,/MANUFACTURING FACILITY•1?75 SAMPSON AVE.•CORONA.CA 92873•PH: 951.737.5599•FAX 95 1.37.0330 CUSTOMER SERVICE•800.1R6.5266 www.tolco.com i 'D L CO www.tolco.com NIB= Revision 9/1/2006 • Fig. 4B - Pipe Clamp for Sway Bracing Component of State of California OSHPD Approved C 0 U LISTED Seismic Restraints System Size Range—3/4" thru 8" pipe. Material —Carbon Steel Function— For bracing pipe against sway and seismic disturbance. c . Features—This product's design incorporates concentric loading of the "brace pipe", A. connection components and fasteners which is critical to the performance of seismic - ' 6 bracing assemblies. e. Approvals— Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). y' Included in our Seismic Restrains Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). Finish— Plain • Note—Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By— Figure number, pipe size and finish. Installation Instructions—The Fig.4B is the 'braced pipe" attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO transitional and structural • attachment component(s) to form a complete bracing 4., assembly. NFPA 13 and/or OSHPD guidelines should be - Shown with two TOLCO® followed. Fig. 980's and Schedule 40 • To Install— Place the Fig.4B over the pipe to be braced. brace pipe. - Attach other TOLCO transitional fitting, Fig.909, 910 or 980. Tighten bolts and nuts. Transitional fitting attach- ment can pivot for adjustment to proper brace angle. t I Fig.4B - Hanger/Longitudinal Brace TOLCOe brand bracing components are desgined to be compatible ONLY with other TOLCO5'brand bracing components,resulting in a Listed seismic bracing assembly. DISCLAIMER—NIBCO does NOT warrant against the failure of TOLCO®brand bracing components,in the instance that such TOLCO'®brand bracing components are used in combination with products,parts or systems which are not manufactured or sold under the TOLCO®brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect,incidental or consequential damages of any kind, including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been,or are used. Dimensions •Weights Pipe Rod Size Max.Design Approx. Sizes A B C D Bolt Size Load Lbs. Wt./100 3/4 3/8 1 27/s 2% 5/16 330 56 1 3/8 1 314 215/ie 5/16 330 60 11/4 3/8 1 3y;6 31 5/16 330 74 12 3/8 1 313/16 Pis 5/16 330 79 • 2 3/8 11/2 51/8 4% 5/16 440 156 21/2 1/2 13 5% 5% 3/8 440 176 3 1/2 1 7.43 63/4 61/2 3/8 660 198 31/2 1/2 2 71/4 63!, 3/8 660 219 4 5/8 2 8We 71/4 1/2 800 288 5 5/8 2 97/s 8&Vic 5/8 980 390 6 3/4 22 1015'16 91/2 5/8 980 448 8 7/8 214 13-/is 111/2 3/4 1200 691 ® OFFICE/MANUFACTURING FACILITY• 375 SAMISEN AVE.•;Ci'iONA CA 92879•PH: 951.737.5599•FAX: 95`.737.0333 CUSTOMER SERVICE•800.786.5266 www.toko.com lg. TOLCD www.tolco.com NIBCC1 Revision 5/27/2008 Fig. 4L c 0 US LISTED Longitudinal "In-Line" Sway Brace Attachment t ► Size Range — 21/2" through 8" IPS. II' Material — Carbon Steel , ,' f, Function — For bracing pipe against sway and seismic disturbance. Approvals — Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL) 21/2" - 8". Approved by Factory Mutual Engineering (FM), 2'/2" - 8" pipe. Installation Instructions — The Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be D A combined with the "bracing pipe' and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install — Place the Fig. 4L over the pipe to be braced and tighten ILI bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to c proper brace angle. Finish — Plain / J� . • Note — Available in Electro-Galvanized and HDG finish. - Order By — Figure number, pipe size and finish. r 4* 9;--/4110 M A © 4-Way Riser Brace r-, (Plan view) I ' I ! I : Dimensions •Weights 111 J Max.Rec. `Max Rec. Sizes A C D Bolt Load Lbs. Load Lbs. App (cULus) (FM) Longitudinal Brace 21/2 6716 2;'z 23/4 1/2 2015 3000 253 3 7 23/4 31/16 1/2 2015 1550 268 4 81 3% 311/1e 1/2 2015 1550 348 5 93/4 31/2 4% 1/2 2015 1450 380 6 111 5 51/2 1/2 2015 1450 640 8 131/4 6"1'ir. 61/2 1/2 2015 1450 728 *Load shown is allowable with brace installed,between 30`-90'.No reduction of load based on brace angle is required. . FM approved when used with 1",11/4",11/2"or 2"Sch.40 brace pipe. TOLCOa brand bracing components are designed to be compatible ONLY with other TOLCO'r'brand bracing components.resulting in a Listed seismic bracing assembly. DISCLAIMER— NIBCO does NOT warrant against the failure of TOLCO0 brand bracing components,in the instance that such - TOLCO®brand bracing components are used in combination with products,parts or systems which are not manufactured or sold under the TOLCOe brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect,incidental or consequential damages of any kind, including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been.or are used. OFFICE/MANUFACTURING FACIUTY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.7 37.5599•FAX 951.7371330 CUSTOMER SERVICE•800.786.5266 III www.tolco.com ot TOLCO www.tolco.com N1BCQ Revision 9/1/2006 Fig. 6 - Riser Clamp C 0 US LISTED Fig. 6F - Felt Lined Riser Clamp 4> Fig. 6PVC - PVC Coated Riser Clamp - Size Range— (Fig. 6) 1/2" thru 20" pipe (Fig. 6F) 1/2" thru 21" copper tubing (Fig. 6PVC) 1/2" thru 6" pipe Material—Carbon Steel - Insulation Material—(Fig. 6F) 3/16" felt. Function —Used for supporting vertical piping. Approvals— Underwriters' Laboratories Listed in the USA(UL), Canada /�/ (cUL) 1/2" -8". Factory Mutual Engineering Approved, 3/4" thru 8". / // I� Conforms to Federal Specification WW-H-171 E,Type 8, 3/4" thru 20" and I Ad��/ f;.� ,� Manufacturers Standardization Society SP-69, Type 8. ��%<<; �� Maximum Temperature—650°F B • �/ Finish— Plain { Fig. 6 Note—Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By— (Fig.6 and Fig.6PVC) pipe size and finish. (Fig.6F) copper tube size and finish.(Fig.6F is available for Iron Pipe Size, consult factory. . , / Y r \ If '06 , 4j1 - ' - - ,,....00000.0°' my Fig. 6PVC Fig. 6F Dimensions •Weights Pipe Max. Rec. Approx. Size A B C Bolt Size Load Lbs. Wt./100 1/2 914 1/2 11/2 3/8 255 144 3/4 91/4 1/2 11/2 3/8 255 144 1 99/is 1/2 11/4 3/8 255 147 11/4 911/is 1/2 1% 3/8 255 150 11/2 103/4 1/2 11/2 3/8 255 153 2 103/4 1/2 2 3/8 255 165 21 11 5/8 214 3/8 390 228 3 12 5/8 3 3/8 530 246 31 13 5/8 314 1/2 670 264 4 13' 3/4 33 e 1/2 810 347 5 141 314 43 e 1/2 1160 385 6 151/8 7/8 478 1/2 1570 564 8 181/2 1 534 5/8 2500 1017 10 201 1 71.:4 5/8 2500 1138 12 223/4 1 814 5/8 2700 1759 14 24 11/2 9 5/8 2700 1922 16 26 11 101/4 3/4 2900 3245 18 28 11/4 111/2 3/4 2900 3372 20 30 13%; 121 3/4 2900 3499 ® OFFICE/MANUFACTURING FACILITY• 275 SAAIFSC N AVE.•C0$0NA.CA 32879•PN: 951.737.5539•FAX. 951.:37.0330 CUSTOMER SERVICE•800.786.526E www.tolco.cwn 1"DLCD _ www.tolco.com NIBCO Revision 3/1/2008 Fig. 25 - Surge Restrainer 0 0 US LISTED Size Range — One size fits 3/4" thru 2" pipe. Material — Pre-Galvanized Steel Function — Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2007 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals — Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA(UL) and )/ 1111 Canada (cUL). Finish — Pre-Galvanized Order By — Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent#5,344,108 _ I SL -; • • • • • OFFICE/MANUFACTURING FACIUTY•'?75 SA61PCr N AVE•CORONA.CA 92879•PH. 951.737.5579•FAX 951.737.0i30 CUSTOMER SERVICE•810.786.526E www.tolco.com TOLCO www.tolco.com ^ NIBCO' Revision 9/1/2006 Component of State of Fig. 120 - "U" Hanger California OSHPD Approved C O us usTEO Seismic Restraints System Size Range— Size 3/4"thru 8" pipe Material —Carbon Steel Function — Used to support piping from wood beams where no contraction is expected. Used extensively in automatic fire sprin- kler systems. Approvals— Meets or exceeds the requirements of National Fire Protection Association (NFPA), Pamphlet 13. Underwriters Laboratories Listed in the USA (UL) and Canada(cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development _A (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Maximum Temperature—750°F LENGTH Finish— Plain (SPECIFY) !� Note—Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By—Figure number, pipe size, length and finish Dimensions Pipe Fastener Max Rec. Size A Size Load Lbs.*** 3/4 5/16 16 x 2* 250 1 5/16 16 x 2* 250 11/4 5/16 16 x 2* 250 11/2 5/16 16 x 2* 250 2 5/16 16 x 2* 250 21/ 3/8 3/8 x 21** 320 3 3/8 3/8 x 21"" 320 31 3/8 3/8 x 21/2— 560 4 3/8 1/2 x 3"* 560 5 1/2 1/2 x 3** 560 6 1/2 1/2 x 3** 760 8 1/2 5/8 X 3** " Drive screw *" Lag bolt *** With minimum safety factor of 5 Fastener schedule per NFPA OFFICE/MANUFACTURING FACIUTY• 375 SAMPSON AVE.•CORONA CA 92879•PI-I. 951.73755N•I AX 95`•.;37.O 3O 36 CUSTOMER SERVICE•800.786.5266 www.tolco.com T O L CO www.tolco.com NIB[X7 Revision 9/1/2006 Fig. 120MJ - Mutt & Jeff "U" Hanger Size Range — Size 3/4" thru 8" pipe Material — Carbon Steel Function — Used to support piping from wood beams where no contraction is expected. Used extensively in automatic fire sprinkler systems. The Mutt & Jeff is used when the wood beam is on a * diagonal. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, pipe size, side length and finish / Fig. 120W - Wrap Around "U" Hanger Size Range — Size 3/4" thru 2" pipe Material — Carbon Steel Function — Required for automatic fire protection agencies to be used on the end of branch lines to prevent pipe from whipping vertical and striking ceiling or beam Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, pipe size, length and finish OFFICE/MANUFACTURING FACILITY•1275 SAMPSON AVL.•CORONA,CA 92879•PH: 9.1.7337.5599•FAX 951.737.0's.30 CUSTOMER SERVICE•800.786.5266 www.tolco.com i' D LCD www.tolco.com NIBCO Revision 6/9/2008 • Fig. 120RWA (Model B) Califorrnia nia OSHPD olStateof O SHPD Approved C ()� US LISTED Seismic Restraints System Retrofit Wrap Around U-Hanger Clamp Size Range— 1" thru 8" pipe Material—Carbon Steel Function—Clamp Model"B"is designed to restrain movement = of the pipe within standard U-hangers as is required by NFPA 13. Where retrofit capability is crucial, the Fig. 120RWA is a labor efficient alternative to the standard TOLCO®Fig. 120W Wrap Around U-Hanger. Features— Installs easily by tightening two hex nuts. Features \ j a unique bracing slot that locks onto a standard U-hanger to become a solid unit that will stabilize the pipe during seismic I` activity or sprinkler head activation. Designed to be used in ret- rofit or new construction applications. Will clamp to existing I U-Hangers without restriction to leg angle �. Approvals— Underwriters' Laboratories listed in the USA (UL) and Canada(cUL) as a restrainer.Included in our Seismic ,� Restraints Catalog approved by the State of California Office '� of Statewide Health Planning and Development(OSHPD). For 1 ! additional load, spacing and placement information relating to „� OSHPD projects. please refer to the TOLCO Seismic Restraint = Systems Guidelines. NFPA 13 (1999) A-6-2.3.3. Finish— Plain and Galvanized. Consult factory for Stainless Steel material. Order By— Figure number, type numbers and pipe size Ordering Note—Order by the following type and pipe size: Type 1 —(1" and 11/4" pipe size) Type 2—(11/2" and 2" pipe size) Type 3 —(21/2" and 3" pipe size) Type 4 —(4' pipe size) Type 6—(5" and 6" pipe size) Type 8—(8" pipe size) Important Note—The bracing slot feature is sized to fit the U- Hanger rod schedule as required by NFPA 13 as follows: 5/16" rod for up to 2" pipe 3/8" rod for 21" - 6" pipe 1/2" rod for 8" pipe For other rod size requirements consult factory. OFFICE/MANUFACTURING FACILITY• 275 SAMI'cC N ra.VE.•:19R0NA.CA 32879•PH: 951.727.5539•1-A.X. 95`.737.0333 CUSTOMER SERVICE•100.786.5265 www.tolco.com (i) ToLco. www.tolco.com NIBCO Revision 3/1/2008 Fig. 200 - "Trimline" Adjustable Band Hanger C UL US LISTED Size Range— 1/2" thru 8" pipe Material —Carbon Steel, Mil.Galvanized to G90 specifications Function— For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger ,"; ;$ adjustment after installation. - i.1::::*: ' Features— I , • (1/2" thru 2") Flared edges ease installation for t I 1 ` I l all pipe types and protect CPVC plastic pipe from / 1 abrasion. Captured design keeps adjusting nut 'Ai p 9 P 1 9 � B I from separating with hanger. Hanger is easily o I ,/ 1 j J l installed around pipe. Il f • (21/z" thru 8") Spring tension on nut holds it A �I, A + securely in hanger before installation. Adjusting / - `� nut is easily removed. l' Approvals—Underwriters'Laboratories listed (1/2" ---1--- thru 8"} in the USA(UL) and Canada(cUL)for steel i and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal 112 THRU 2 INCH PIPE ---'- 2 1/2 THRU 8 INCH PIPE Specifications WW-H-171 E,Type 10 and Manufacturers Standardization Society SP-69,Type 10. Maximum Temperature—650°F ∎s''{ Finish— Mil.Galvanized. For Stainless Steel materi- -- — •als, order TOLCO®Fig.200WON. r.ri Order By— Figure number and pipe size 1, `� Note— For removable nut feature, order Fig.200 S 'i�,, ',, �\ /,, - / , Dimensions •Weights Pipe Rod Size Max.Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31 2% 400 11 3/4 3/8 8mm or 10mm 31/2 21/2 400 11 1 3/8 8mm or 10mm 33% 2% 400 12 13/4 3/8 8mm or 10mm 33/4 2% 400 13 11/2 3/8 8mm or 10mm 37'8 27/3 400 14 . 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 558 41/2 600 27 3 3/8 10mm 57 4 600 29 31/2 3/8 10mm 731/2 51/4 600 34 4 3/8 10mm 7% 5 1000 35 5 1/2 12mm 91/2 61/4 1250 66 6 1/2 12mm 101/2 63/4 1250 73 8 1/2 12mm 1311/2 834 1250 136 OFFICE/MANUFACTURING FACILITY•1'75 SAMPSON AVE.•CO.1ONA,CA 92879•PH. 951.737.5599•FAX 951.737.0330 CUSTOMER SERVICE•800.708.5266 III www.tolco.com TDLco" „r,�„„,.toico.�o�„ a 'NIBCO' Revision 4/30/2008 • Fig. 200H - Heavy Duty Band Hanger (for Trapeze) c 0 US USTEG Size Range — 2" thru 4" trapeze pipe size. Used to support up to 8" pipe. For 6" and 8" trapeze pipe, consult factory. Material — Carbon Steel — Pre-Galvanized to G40 Spec Function —Designed primarily to support ! T O L C O www.tolco.com NIBCO' Revision 1/24/2007 Fig. 200WON - "Trimline" Adjustable Band Hanger w/o Swivel Nut Size Range— 1/2" thru 8" pipe Material —Carbon Steel A c e US LISTED Function — Recommended for the suspension of fire ...• sprinkler and non-insulated pipe or insulated pipe with .- Fig.220 shield. Generally installed with two hex nuts. _� Features— Flared edges on sizes 1/2"thru 2". Eases � , installation and protects CPVC pipe from any abrasion. Approvals—Underwriters' Laboratories listed I (1/2" thru 8") in the USA (UL)and Canada(cUL)for steel and CPVC plastic pipe. Conforms to Federal / Specifications WW-171E, Type 7 and Manufacturers ,, Standardization Society SP-69,Type 7 ..-,..,\ Maximum Temperature—650°F 1• Finish— Mil.Galvanized to G-90 C Note— Available in Stainless Steel materials Order By— Figure number and pipe size B / Dimensions •Weights Pipe Rod Size Max. Rec. Approx. Size A B C Load Lbs. WtJ100 1/2 3/8 21/2 2 400 8 3/4 3/8 21/2 2 400 8 1 3/8 21/2 21/4 400 9 11/4 3/8 3% 21/2 400 10 11/2 3/8 3" 21/2 400 11 2 3/8 33/4 21 400 12 21/2 3/8 51/2 3% 600 24 3 3/8 5% 31 600 27 31/2 3/8 63/4 4% 600 32 4 3/8 63/4 41/2 1000 33 5 1/2 83 51 1250 60 • 6 1/2 9% 6 1250 68 - 8 1/2 12% 8 1250 130 OFFICE/MANUFACTURING FACILITY•1?75 SAMPSON AVL.•CORONA.CA 92879•P11: 951.737.5599.1AX 951.737.0330 CUSTOMER SERVICE•R00.7116.5266 www.toko.com FireLock EZ® Rigid Coupling ✓4taulicr Style 009N 10.64 Material Specifications: • .410:"I*; 1 - Housing: • Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. PATENTED Housing Coating: Approvals/Listings: Orange enamel (North America,Asia Pacific) Red enamel (Europe) c WE eus FM LPCB CM Optional: Hot dipped galvanized See Victaulic Fubllcabon 10.01 for more details. Gasket: — — — — — Grade "E" EPDM (Type A) Product Description: — — FireLock EZ products have been Listed by Underwriters The FireLock EZ Style 009N coupling is a rigid, Laboratories Inc.,Underwriters Laboratories of Canada Limited,and Approved by Factory Mutual Research for installation-ready coupling for fire protection pipe joining. wet and dry(oil free air)sprinkler services within the rated The coupling's unique design eliminates loose parts, working pressure. insures consistent installation and provides substantial gains in productivity. Bolts/Nuts: IMPORTANT Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and FireLock EZ Style 009N couplings are recommended for use physical requirements of ASTM A 183. se ONLY on fire protection systems. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date • Couplings I Rigid I Style 009N I Publication 10.64 10.64 7072 Rev D Updated 11/2013 0 2013 Vlctaullc Company.All rights reserved. victaulic.com 1 ictaulic ll 1 r 4 Couplings I Rigid I Style 009N I Publication 10.64 .. Listings/Approvals I The information provided below is based on the latest listing and approval data at the time of publication. . Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size cULus FM Vds LPCB Sch.5 Sch.10 Sch.40 Sch.5 Sch.10 50.40 inches psi psi psi psi psi psi psi psi mm kPa kPa kPa kPa kPa kPa kPa kPa 1V4 363 363 363 232 365 365 365 365 32 2502 2502 2502 2000 2517 2517 2517 2517 11 363 363 363 232 365 365 365 365 40 2502 2502 2502 2000 2517 2517 2517 2517 2 363 363 363 232 365 365 365 365 50 2502 2502 2502 2000 2517 2517 2517 2517 21 363 363 363 365 365 365 365 65 2502 2502 2502 N/A 2517 2517 2517 2517 76.1 mm N/A WA N/A N/A N/A N/A 1 365 2517 2517 3 363 363 363 365 365 365 365 80 2502 2502 2502 N/A 2517 2517 2517 2517 4 363 363 363 365 365 365 365 100 2502 2502 2502 N/A 2517 2517 2517 2517 133.0mm Refer to Submittal 10.61 139.7 mm Refer to Submittal 10.61 165.1 mm Refer to Submittal 10.61 6 Refer to Submittal 10.61 150 1 Listed/Approved for wet and dry pipe systems(>-407/-40`C)for continuous use in freezing conditions,use of silicone gaskets Is recommended. Please refer to the Victaulic Installation Manual(I-009N/009H)for details concerning when supplemental lubrication Is required. Speciality Pipe i- - Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe Size Pressure Rating cULus FM cULus FM cULus ' FM Sch. inches psi psi Sch. Inches psi psi Sch. inches psi psi kPa kPa kPa kPa kPa kPa BLT 114-2 300 300 EZT 116-2 300 300 MT 114-2 300 300 2068 2068 2068 2068 2068 2068 DF 176-4 2 6 2 FF 114-4 300 2068 MIT 176-2 N/A 300 DT 114-2 2068 � 2068 FLF 114-4 WA 2 ST 114 2 WA I 2068 EF 1 Y4-4 175 175 FLT 174-2 N/A 300 STF 114-4 N/A 300 1206 1206 __I _—_— 2068 - 2068 EL 114-2 2068 2068 FLTL 114-2 N/A Z�B TF 274-4 l N/A 2�8 _ __ _ 1-...--+ -- — ET40 134-2 300 300 1 -2 300 300 WLS 1 Y4-2 300 300 2068 2068 I 2068 2068 2068 2068 300 300 ( I 300 300 I 300 EZF 3-4 2068 2068 MF 114-4 1 2068 I 2066 WST 114-2 WA 2068 . 300 300 XL 1 114-2 2068 2068 — — —__ 10.64 7072 Rev D Updated 11/2013 0 2013 Vlctaullc Company.All rights reserved. victaulic.com 2 rctaul,c • / 4 Couplings I Rigid I Style 009N I Publication 10.64 Style 009N Dimensions: \,J 7 r \,� Style 009N Pre-Assembled Style 009N Joint Assembled (Push On Condition) F _ Dimensions Pre-assebled Actual Maximum Maximum Allow. (StabinConditior>) Joint Assembled Approx. Nominal Outside 1 Working End Pipe End Weight Size Diameter i Pressure' Load' Separation' Bolt/Nuts X Y X Y Z Each inches inches psi lbs. : inches (No.)size inches Inches Inches Inches inches lbs. mm mm kPa N mm inches mm mm mm mm mm kg 11/4 1.660 365 790 0.10 (2)3/4x2 3.10 4.90 2.70 4.90 1.92 1.4 32 42.4 2517 3514 254 (M)10 x 2 79 124 69 124 49 0.7 11/2 1.900 365 1035 0.10 (2)3/4x 2 3.30 5.10 1 3.00 5.10 1.92 1.5 40 48.3 2517 4604 2.54 (M)10 x2 84 129 76 129 49 0.7 2 2.375 365 1616 0.12 (2)34x2 3.90 5.60 3.50 5.60 1.95 1.9 50 60.3 2517 7193 3.05 (M)10 x 2 99 142 l 89 142 50 0.9 215 2.875 365 2370 0.12 (2)3/4 x 216 4.50 6.10 4.00 6.10 1.95 2.1 65 73.0 2517 10542 3.05 (M)10 x 216 114 155 102 155 50 1.0 76.1 mm 3.000 365 2580 0.12 (2)%x 215 4.56 6.00 4.05 6.06 1.94 2.1 76.1 2517 11476 3.05 (M)10 x 21/2 115.7 152.5 102.8 153.9 49.2 1.0 3 3500 365 3512 0.12 (2)34 x 214 5.10 6.70 4.60 6.70 1.95 2.3 80 88.9 2517 15622 3.05 (M)10 x 215 129 170 117 170 50 1.0 - 4 4.500 365 5805 0.17 (2)%x2½ 5.95 7.80 554 7.47 2.14 2.9 100 114.3 2517 25822 4.32 (M)10 x 216 151 199 141 190 55 1.3 108.0mm Refer to Submittal 10.61 133.0mm Refer to Submittal 10.61 139.7 mm Refer to Submittal 10.61 165.1 mm Refer to Submittal 10.61 6 Refer to Submittal 10.61 150 1 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See page 1 of this document for Listed/Approved ratings on other pipe.WARNING:FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be Increased to 1/times the figures shown In the chart on page 1,specific to pipe schedule and size. 2 The allowable pipe separation dimension shown is for system layout purposes only.FlreLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 3 Number of bolts required equals number of housing segments. General Notes: NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZ Style 009N couplings,use FlreLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ" marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There Is no interchanging of gaskets or housings between coupling styles. Use Of Flushseal Gaskets For Dry Pipe Systems NOTE:FireLock EZ couplings are supplied with FireLock EZ Grade"E"Type A gaskets.These gaskets Include an integral pipe stop,that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. • Installation Note Reference should always be made to the I-100 Victaullc Field Inlisilabon Handbook for This product shall be manufactured by Victaulic or to Vlctaullc specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic 10 be installed in accordance with current Victaulic installation/assembly Instructions. products for complete installation and assembly data,and are available In PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www,victaullc.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaullc for details. Victaullc and FireLock E2 are registered trademarks of Victaulic Company. 10.64 7072 Rev D Updated 11/2013 O 2013 Vlctaullc Company.All rights reserved. victaulic.com 3 rctaulic ,, . . Dyna-Flow® High Strength Steel Pipe The original high-strength lightwall sprinkler pipe with hydraulics superior to Schedule-10. Dyna-Flow pipe is the`original"high- Specifications strength lightwall sprinkler pipe.Dyna- Flow has outstanding hydraulic NPS Nominal I.D. Wt. WI.(H20 Filled) Pcs/ WI/Lift(21') Wt/Lift(24') Wt/Lift(25') capabilities and is recognized as the In;mm In;mm Lbs/Ft;Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg most popular alternative to Schedule-10 1' 1.191 0.830 1.31 91 1,586 1,812 1,888 pipe.Lightweight,easy to cut and easy 25 30.3 1.2 1.95 91 719 822 856 to handle for installation.Dyna-Flow is a 1'/<" 1.536 1.059 1.87 61 1,356 1,550 1,615 valuable addition to any fire protection 32 39.0 1.6 2.78 61 615 703 733 system. 11/2" 1.728 1.667 2.71 61 2,135 2,440 2,542 Superior Hydraulics 40 43.9 2.5 4.03 61 968 1107 1153 2' 2.203 2.104 3.79 37 1,634 1,868 1,946 With an inside diameter of up to 11% 50 56.0 3.1 5.64 37 741 847 883 larger than Schedule-40 and up to 7% 21/2" 2.703 2.564 5.10 30 1,615 1,846 1,923 larger than Schedule-10, Dyna-Flow 65 68.7 3.8 7.59 30 733 837 872 pipe hydraulics are exceptional.Larger 3" 3.314 3.387 7.18 19 1,351 1,544 1,608 I.D.s enable Dyna-Flow,and related 80 84.2 5.0 10.69 19 613 700 729 components,to be down-sized within the 4" 4.310 4.473 10.86 19 1,784 2,039 2,124 system,thus increasing the potential for 90 109.5 6.7 16.16 19 809 925 963 job cost savings.For complete Hazen- Williams charts,refer to"Dyna-Flow Hydraulic Data Tables." Coatings & Fabrication Specifications & Approvals Additional Benefits Dyna-Flow products are coated with Dyna-Flow/Super Flo pipe is manufac- • Lightweight and easy to install, an environmentally approved and Lured to meet ASTM A-795 Type E, resulting in more efficient use of your specially formulated modified-acrylic or Grade A and is in compliance with freight and labor dollars. water-based coating.This durable coating NFPA-1 3 and NFPA-14.All sizes of is paintable.The black coating acts as Dyna Flow/Super Flo are UL Listed,FM • Provides stability needed to comply Approved and ULC Listed. an excellent primer and is resistant to with standard hanger spacing (15 ft O.C.)per NFPA. weathering and U.V. degradation from outdoor storage. Q ® ® • Available in Standard lengths for your Metallurgical properties provide excellent Listed Approved Listed convenience,or can be ordered in fabrication characteristics for end prep custom lengths upon approval. finishes,welding and roll grooving. Dyna-Flow/Super Flo is UL/ULC Listed ' g g for use with roll grooved,plain-end • Fast cutting and welding,as well as There is no special process or equipment couplings,and welded joints for wet,dry, easy roll grooving and end preparation. needed for fabrication and installation. preaction and deluge systems. It is FM • Available in Factory roll grooved form The internal surface of all black Allied Approved for roll grooved,plain-end,and for quicker shop turnaround. Tube&Conduit Fire Sprinkler pipe welded joints for wet systems.Refer to products up to 4.5000"in diameter is appropriate documentation for up-to-date • Clean,durable mill coating provides coated with our new Antibacterial listing and approval information. Dyna- longer"shelf life"and acts as an Formula,"ABF". In scientific laboratory Flow/Super Flo is now available"hot- excellent primer for custom paint test,ABS proved to have superior dip"galvanized and has been specifically applications. resistance to microbial colonization of approved by FM for dry systems uses. pipe walls,thereby delaying or possibly _ preventing the onset of Microbiologically Influenced corrosion(MIC)when the . First Sprinkler System is first installed. 16100 S. Lathrop• Harvey, IL 60426 Customer Service: N CO/Flow Control allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800)882-5543 TUBE&CONDUIT 2525 N.27th Ave. •Phoenix,AZ 85009 Fax 708-339-1806 S2- 3 , , , Dyna-Thread® - M-COAT® Submittal Data Sheet ® Full Line Sch-40 Replacement Dyna-Thread—M-COAT Specifications Dyna-Thread`'—M-Coat'sprinkler pipe represents an engineering NPs Nominal I.D. Wt. Wt.(H20 Filled) ERR ERR advancement for the sprinkler pipe industry.It combines the safety In;mm In;mm Lbs/Ft kg/m LbsIFt;kg/m Unthreaded Threaded and longevity of traditional Sch-40 pipe with quality and superior 1" 1.080 1.330 1.75 11.39 1.00 hydraulic advantages. 25 27.4 2.0 2.60 — — 11b" 1.408 1.870 2.54 9.50 1.00 ® Comparison to Schedule 40 32 35.8 2.8 3./8 - - 11/2" 1.639 2.290 3.22 9.14 1.00 Dyna-Thread¢'—M-Coat'inside diameter is up to 3.6%larger than Sch-40 40 41.6 3.4 4.79 - - giving it superior hydraulics.Also,when used in combination with Dyna- 2" 2 104 3.050 4.57 8.41 1.00 Flow—M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 - - approved UL,ULC,and FM for fire sprinkler applications.The life expectancy - of Dyna-Thread—M-Coat and Sch-40 are equal based on the calculated wall ® a® - thicknesses per UL.The consistent quality of steel used to make Dyna-Thread— APPROVED M-Coat facilitates smooth threading and lower maintenance costs.The exterior • of Dyna-Thread—M-Coat is protected by a clean,durable mill coating for 4 American Made extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available and lighter weight, Dyna-Thread—M-Coat reduces installation fatigue and through distributors in the USA,Canada,Mexico,and is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR)is a UL Latin America. (Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed 4 Specifications &Approvals thread,assumed to be the weakest point of the pipe length.Dyna-Thread— M-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread—M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with NFPA-13.All sizes of Dyna-Thread—M-Coat are rated at 300 psi working O Comparison to L.W.T. Pipe pressure.Dyna-Thread—M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread—M-Coat dry and pie-action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints.Dyna-Thread— use in wet systems.Dyna Thread—M-Coat is approved for all M-Coat is approved for standard hanger spacing(15 ft.O.C.),can be used as threaded couplings and welded outlets and is suitable for all earthquake sway bracing,and is safe to use as drops.Dyna-Thread—M-Coat roll grooved,and plain end fittings.(See listing information). is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread—M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: 9'allied Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com • 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUIT' Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 "'""`:mil` 02013 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1301 CA = .. . e= •- , i�' ; 7 x f (11.! t /.0 it-- :'..L.,.4.1.1t..4, P2- ',. ro, .ri f�� E.r 't 1.0 4rf '. ai. ; �S 'K r,' Oda Y1", { i a 5 UfI (/Ih/I 4 i}, 4" "`i " ° y+ 4 _ ;! i ..yr „ a 4,y d •.) fik.- 4 k °b& a 4 . - , .4 °Ytp`y y Y1'M{�+ + V.4, ..,;‘,... ..:,..,..,..„.....h....„::„.,,,,,,,A'.,-',',,'::.:4L., , ., 1_., . I, \ ,tt • .L t .., .._ N_ ; i , . 1,, 4i 14. ..4...„. . .„.,. ., ,, .,,,„.„..,,,,..4.1.,...,,..„.,,,0,4,;,,, El.” - - l' ; l' ' •1 I. •-`,; _ - '.,:--b•+',--k0,-,: +1,./t-si.-+r--„N.t,,,,..-..+, : k,,+, _„_,_a 3 ..* �,FMS4i.4> '4'" s.ss 4a♦ �'4 'M `. x ' tl � = _t.-,1,,••,, • r g"T a� «° 4 �rx,y x a 4+.+Z. ..-,,.-4 . 'a'. g'� +1 Y 3 � T F Jr t s}Z r' a x yi' . 'I P T ^O u'' ' 4"'" :r :h h x1�}rte , moill t •diz r IQ a • fi Jr, } 'T eft € .� �, ,�«:w ,.,k�- ,, ' I N T E R N A T I O N A L Ductile Iron Threaded Fittings Specifications • branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP C 4 L us • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 41> • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 k / a " -' Ductile Iron Fittings-Class 300 UL/FM . c (14) us 40111" APPROVED Fig. 35E 3- 90°Elbow LISTED A Size A Packing Weight `■ in Part Number in Inner Master lb %\. 1/2 35E 3004 1.13 100 200 0.2 `" i 3/4 35E 3006 1.31 70 140 0.3 11I I A 1 35E 3010 1.50 40 80 0.5 1= 1 1-114 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow B Size A B Packing Weight (---) in Part Number in in Inner Master lb I 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 .` I 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 IIFM A 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 v 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 . 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 . 1-1/4 x 1 35RE301201D 1.58 1.67 30 60 0.7 • 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 • 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 4` 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 13 "f 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 :.f} 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 E Fig. 35F 3- 45°Elbow Size A Packing Weight Part Number X∎, in in Inner Master lb � 1/2 35F 3004 0.88 150 300 0.2 � i1 3/4 35F 3006 0.98 80 160 0.3 1%41k 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 • IA 1-1/2 35F 3014 1.44 20 40 1.0 !� 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size Part Number A Packing Weight 4. - __ in in Inner Master lb • �! 1/2 35T 3004 1.13 80 160 0.3 " I I IA 3/4 35T 3006 1.31 30 60 0.5 . 11 \i; I= =I 1 35T 3010 1"50 25 50 0.7 \L�4 1-1/4 35T 3012 1.75 10 20 1.1 A I A 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 . 2-1/2 35T 3024 2.70 4 8 4.3 111 S'\11TH-COOPER 1NTERNAT1ONAL • TOLL FREE 1-800-7(>6-0076 • FAX(323)890-4456 • \IAN w.smithcooper.corn r / 6 t`) i f uctile Iron Lttings- ass 11 T u•.u.r� ills • . C ® Ds APPROVED Fig. 35RT3-Reducing Tee LISTED _ Size A B C Packing Weight 1111 __ { r LIPI in Part Number in in in Inner Master Ib �� r IC 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 x,1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1x314 35RT3010006 1.38 1.38 1.45 25 50 0.6 B�A 1 x 3/4 x 314 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75, 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 ' 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 • 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 • 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 . 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 • 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 • 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 . 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 l x 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 lI I ' 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 I` :< 1 -1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 f t, 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 i 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 . Fig. 35BT3-Bull Head Tee - Size A B C Packing Weight _- ; Part Number in in in in Inner Master lb r �C 314 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 • 1 \ -, 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 !^ 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 A{B 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 358T3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNAT1ON.A1 • TOLL FREE 1-800-7r66-0076 • FAX(323)S%-1456 • www.sminccooper.ccm 112 r, 1. Pt t .., , ,i Ductile Iron Fittings-Class 300 UL/FM . ',4L'.L.riii?WS , 4 . C41) US APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size Part Number A Packing Weight in in Inner Master lb 1/2 35C P3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35C P3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size Part Number A Packing Weight Ain% IA in in Inner Master Ib x 1/2 35RC3010004 1.69 60 0.3 1 x 3/4 35RC3010006 69 60 120 0.4 0.6 -_ 1-1/4 x 3/4 35RC3012006 2.06 20 2 x 1(not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight ?' B in in Inner Master lb • 1 x 1/2 35HB3010004 1.06 180 360 0.2 ^A 1 x 3/4 35HB3010006 1.06 180 360 0.1 ``` s;= IMMI'III 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 • -e:...-ry,;=:� � 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug Size Part Number A Packing Weight in in Inner Master lb 1/2 35SP3004 0.94 600 1200 0.07 A 3/4 35SP3006 1.12 350 700 0.1 ' `"_""° ell' f 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U3- Union with Brass Seat !. A Size A Packing Weight Part Number ,. . in in Inner Master lb rt, 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1,‘�� 1-1/2 35U 3014 2.62 10 20 1.7 ,;' ...0` 2 35U 3020 3.12 6 12 2.4 0 .,3 113 SMITH-COOPER INTERNATIONAL"' • TOLL FREE 1-SOO-766-O(J7h • FAX 323)890-•45h • VANcsmithamIper.coM l 1 V I}, 7 0 i ucti le ron fittings- ass I I 1 Y . I Qtiit.>rz PLES . C4) US APPROVED Fig. 35X 3- Cross LISTED A A Size A Packing Weight p Part Number ..iiIiiti 35X 3010 in 1 in 1.50 Inner 20 Master 40 lb i 0.9 ___1___ I 1-1/4 35X 3012 1.75 12 24 1.4 I �_ I A 1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 B B Fig. 35RX3-Reducing Cross ` '` ' Size part Number A B Packing Weight �'!�I� I A in in in Inner Master lb 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 s, .‘ lir -I I 111 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 A 2 x 1 35RX3020010 2.02 1.73 8 16 4 Fig. 35C3- Cap - Size part Number A Packing Weight ii ` I\ in in Inner Master Ib A 112 35C 3004 0.87 3U0 600 0.1 3/4 35C 3006 0.97 200 400 0.1 I _ 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 350 3024 1.70 18 36 1.6 Fig. 35BC3-Beam Clamp Size A Packing Weight �I Part Number 4 A in in Inner Master lb ■ 3/8 35BC3003 0.75 100 200 0.3 II In 1/2 35BC3004 0.75 80 160 0.5 a SMITH-COOPER INTERNATIONAL' • TOLL FREE I-800-766-0076 • FAX(323)510-4.156 • w w.srnithcuilper.wm 114