Loading...
Report ff2oI1-I - oor-7-1 r ‘20[0q Co s:604-h . Vico RECEIVED Worldwide www.tyco-fire.com Fire Protection OCT 27 2014 Contacts ciTyoF[IGLU Series TY-B, 5.6 K-factorcu 1nse Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General NOTICE _ s The Series TY-B Sprinklers described { '",.1" a....--.1. Description herein must be installed and maintained in compliance with this document, as .. -.1 The TYCO Series TY-B, 5.6 K-factor, well as with the applicable standards Upright(TY315)and Pendent(TY325) of the National Fire Protection Associa- r Sprinklers described in this data sheet tion,in addition to the standards of ecti .. _ - , Ar.i are standard response,standard cover- other authorities having jurisdiction. . 2 age, decorative 5 mm glass bulb type Failure to do so may impair the perfor- (` spray sprinklers designed for use in mance of these devices. - _ -� light, ordinary, or extra hazard, com- . -- mercial occupancies such as banks, The owner is responsible for maintain- -- �-- hotels, shopping malls, factories, ing their fire protection system and -�--- refineries,and chemical plants. devices in proper operating condition. The installing contractor or sprinkler The recessed version of the Series manufacturer should be contacted with TY-B Pendent Sprinkler, where appli- any questions. _ . cable,is intended for use in areas with a I finished ceiling.This recessed pendent sprinkler Sprinkler ..., sprinkler uses one ne of the following: • A two-piece Style 15 Recessed identification Escutcheon with recessed adjust - 't' ment up to 5/8 inch (15,9 mm)from Numbers (SINS) fi., the flush pendent position. • A two-piece Style 20 Recessed TY315 Upright 5.6K, 1/2"NPT +f' Escutcheon with recessed adjust- TY325 Pendent 5.6K, 1/2"NPT ,,•ment up to 1/2 inch (12,7 mm) from the flush pendent position. Technical The adjustment provided by the Temperature Ratings Recessed Escutcheon reduces the Data 135°F(57°C) accuracy to which the fixed pipe drops (68°C) Approvals to the sprinklers must be cut. pp 175°F(79°C) UL and C-UL Listed 200°F(93°C) Intermediate level versions of Series FM,LPCB,and VdS Approved 286°F(141°C) TY-B Sprinklers are described in CE Certified 360°F(182°C)t Technical Data Sheet TFP352.Sprinkler guards and shields are described in Sprinklers with Polyester Finish are t UL,C-UL,and VdS Approved only Technical Data Sheet TFP780. UL and C-UL Listed as Corrosion- Resistant Sprinklers. Finishes Sprinkler:Refer to Table A Maximum Working Pressure Recessed Escutcheon:White Coated, 175 psi(12.1 bar) Chrome Plated,or Brass Plated 250 psi(17.2 bar)* *The maximum working pressure of 250 psi Physical Characteristics (17.2 bar)only applies to the listing by Un- Frame Bronze IMPORTANT derwriters Laboratories,Inc.(UL). Button Brass/Copper Always refer to Technical Data Discharge Coefficient Sealing Assembly Stainless Sheet TFP700 for the "INSTALLER K=5.6 Discharge Coefficient ient LPM/bar��) Steel w/TEFLON WARNING" that provides cau- Bulb Glass tions with respect to handling and Compression Screw Bronze installation of sprinkler systems and Deflector Bronze components.Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP152 V TFP152 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* ,. — 5 =5 7/16" R_(11,1 mm) !' ' t lE c 4 NOMINAL /111 � ' MAKE-IN (50,82"m m) �2 D 2" 1-3/8"3 ' (50,8 mm) (34,9 mm) I ` WRENCH S f ! / FLATS 1/2"NPT** DEFLECTOR* -- 2-7/8"(73,0 mm)DIA. - CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE cc, Operation Installation WRENCH RECESS The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor, expands when exposed to heat.When Upright(TY315)and Pendent(TY325) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. ,...../17... glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb y type sprinkler if - W-TYPE 6 the bulb is cracked or there is a loss of SPRINKLER WRENCH Design liquid from the bulb.With the sprinkler held horizontally, a small air bubble WRENCH Criteria should be present.The diameter of the air bubble is approximately 1/16 inch RECESS The TYCO Series TY-B, 5.6 K-factor, (1,6 mm) for the 135°F (57°C) to 3/32 Upright(TY315)and Pendent(TY325) inch (2,4 mm) for the 360°F (182°C) �,yr Sprinklers are intended for fire protec- temperature ratings. sl tion systems designed in accordance IIwith the standard installation rules A leak-tight 1/2 inch NPT sprinkler recognized by the applicable Listing joint should be obtained by applying a or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14 is based on the requirements of NFPA ft.-Ibs. (9,5 to 19,0 Nm). Higher levels ...,0 13, and FM Approval is based on the of torque may distort the sprinkler inlet PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the tion Data Sheets). Only the Style 15 sprinkler. IN TO ENSURE or Style 20 Recessed Escutcheon,as p p ENGAGEMENT Do not attempt to compensate for WITH SPRINKLER applicable, is to be used for recessed insufficient adjustment in the escutch- WRENCHING AREA pendent installations, eon plate by under-or over-tightening FIGURE 3 the sprinkler. Readjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in . the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP152 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/8"DIA. sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench (Figure 2). With reference to Figure 1,apply the W-Type 2-1/4'DIA. 6 Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15.9 mm) Recessed Pendent Sprinklers \ - FLUSH The Series TY-B Recessed Pendent — 1 I Sprinklers must be installed in accor- 3/±7,9 m dance with the following instructions. (9,5±7,9 mm) : 1v Step A.After installing the Style 15 or MOUNTING �d 1/8" J Style 20 Mounting Plate,as applicable, SURFACE (3,2 mm) over the sprinkler threads and with –�-- pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34.9 mm) threads,hand-tighten the sprinkler into TY-B PLATE 3/4 the sprinkler fitting. "(19,1 mm) FIGURE 4 Step B.Tighten the sprinkler into the SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) sprinkler fitting using only the W-Type WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench (Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. — sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After the ceiling is installed or SPRINKLER 2-1/4"DIA. the finish coat is applied, slide on the FITTING (57,2 mm) Style 15 or Style 20 Closure over the 5/16±1/4" Series TY-B Sprinkler and push the (7,9±6,4 mm) 1/2"(12,7 mm) Closure over the Mounting Plate until ; FLUSH its flange contacts the ceiling. _, I . i Care and t I /�T " — } MOUNTING ' J 1/8" Maintenance SURFACE (32 mm) The TYCO Series TY-B, 5.6 K-factor, - 1 Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-B PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) main control valve for maintenance WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. The owner is responsible for the system from the proper authorities Sprinklers that have been exposed to inspection,testing,and maintenance of and notify all personnel who may be corrosive products of combustion, but their fire protection system and devices affected by this action. have not operated,should be replaced in compliance with this document, as Absence of the outer piece of an if they cannot be completely cleaned by well as with the applicable standards escutcheon, which is used to cover wiping the sprinkler with a cloth or by of the National Fire Protection Associa- a clearance hole, can delay sprinkler brushing it with a soft bristle brush. tion (e.g., NFPA 25), in addition to the operation in a fire situation. Care must be exercised to avoid dam- standards of any other authorities hav- age to the sprinklers -before,during, •ing jurisdiction. Contact the installing The owner must assure that the and after installation.Sprinklers dam- contractor or sprinkler manufacturer sprinklers are not used for hanging aged by dropping, striking, wrench regarding any questions. any objects and that the sprinklers are twist/slippage, or the like, must be Automatic sprinklers are recommended only cleaned by means of gently dust- replaced. P ing with a feather duster; otherwise, replaced. Also, replace any sprinkler to be inspected,tested,and maintained non-operation in the event of a fire or that has a cracked bulb or that has lost by a qualified Inspection Service in inadvertent operation may result. liquid from its bulb. (Ref. Installation accordance with local requirements Section.) and/or national codes. Sprinklers which are found to be leak- Thereafter, annual inspections per ing or exhibiting visible signs of corro- NFPA 25 are re uired;however, instead • Sion must be replaced. q of inspecting from the floor level, a Automatic sprinklers must never be random sampling of close-up visual painted, plated, coated, or otherwise inspections should be made. altered after leaving the factory. TFP152 Page 4 of 4 P/N* 77 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 570 5.6K UPRIGHT(1/2'NPT) TY315 1 NATURAL BRASS 135 135°F(57'C) 571 5.6K PENDENT(1/2"NPT) TY325 3 PURE WHITE(RAL9010)" 155 155`F(68°C) POLYESTER 'Use suffix"I"for ISO 7-1 connection; SIGNAL WHITE(RAL9003) for example.77-570-4-175-I 4 POLYESTER 175 175°F(79°C) 9 CHROME PLATED 200 200°F(93°C) Eastern Hemisphere sales only 286 286°F(141°C) 360 360°F(182'C) 000 OPEN"' —OPEN indicates sprinkler assembly without Glass Bub. Button,and Sealing Assembly TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- . www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent(specify)Sprinkler,SIN (specify), K=5.6, Standard Response, (specify) temperature rating,(specify)finish,P/N (specify,refer to Table A) Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify')finish, P/N(specify*) Specify:Style 20 Recessed Escutcheon with(specify*)finish,P/N(specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. tyco TEFLON is trademark of The DuPont Corporation. Fire Protection Products Dyna-Thread® - M-SSAT® Submittal Data Sheet 0 Full Line Sch-40 Replacement Dyna-Thread-M-COAT Specifications Dyna-Thread`-M-Coat sprinkler pipe represents an engineering NPs Nominal I.D Wt. Wt.(1-120 Filled) CRR CRR advancement for the sprinkler pipe industry.It combines the safety In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/m Unthreaded Threaded and longevity of traditional Sch-4r pipe with quality and superior 1" 1.080 1.330 1.75 11.39 1.00 - hydraulic advantages. 25 27.4 2.0 2.60 11/4" 1.408 1.870 2.54 9.50 1.00 Comparison to Schedule 40 32 35.8 2.8 3.78 — — 1'/" 1.639 2.290 3.22 9.14 1.00 Dyna-Thread"-M-Coat'inside diameter is up to 3.6%larger than Sch-40 40 41.6 3.4 4.79 — - giving it superior hydraulics.Also,when used in combination with Dyna- 2" 2.104 3.050 4.57 8.41 1.00 Flow-M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 - - approved UL, ULC,and FM for fire sprinkler applications.The life expectancy of Dyna-Thread-M-Coat and Sch-40 are equal based on the calculated wall ® c® thicknesses per UL.The consistent quality of steel used to make Dyna-Thread- APPROVED M-Coat facilitates smooth threading and lower maintenance costs.The exterior of Dyna-Thread-M-Coat is protected by a clean,durable mill coating for ® American Made extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available and lighter weight,Dyna-Thread-M-Coat reduces installation fatigue and through distributors in the USA,Canada, Mexico,and - is ideal for letro-fit applications.Corrosion Resistance Ratio(CRR)is a UL Latin America. (Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed O Specifications & Approvals - thread,assumed to be the weakest point of the pipe length.Dyna-Thread- M-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread-M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CPR of 1.00. 135,Type E Grade A,and is in compliance with NFPA-13.All sizes of Dyna-Thread-M-Coat are rated at 300 psi working OO Comparison to L.W.T. Pipe pressure.Dyna-Thread-M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread-M-Coat dry and pre action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints.Dyna-Thread- use in wet systems. Dyna Thread-M-Coat is approved for all M-Coat is approved for standard hanger spacing(15 ft.0.C.),can be used as threaded couplings and welded outlets and is suitable for all earthquake sway bracing,and is safe to use as drops.Dyna-Thread-M-Coat roll grooved,and plain end fittings.(See listing information). is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread-M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. Project: Sprinkler Contractor: Date: ' Engineer: Specification Reference: Type: System T Y Y Locations: Comments: allied Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com • 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUIT° Harvey,IL 6042 6 Philadelphia,PA 19154 Phoenix,AZ 85009 """=", ®2013 Atkore International,Inc.All Rights Reserved.STP-53-4M-1301 v S \ . Y 1 ucti e ron fittings - ass I I 1 / QUALM P1115 C10 US APPROVED • Fig. 35E 3-90°Elbow LISTED A Size A Packing Weight o, ` in Part Number in Inner Master lb '::' \ 1/2 35E 3004 1.13 100 200 0.2 41 s' 1 ' •• 3/4 35E 3006 1.31 70 140 0.3 `l - A 1 35E 3010 1.50 40 80 0.5 �MB 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow �_ , Size Part Number A B Packing Weight ft \r► 0,P-.� in in in Inner Master , lb F' ' 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 A 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 liji-' 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 • 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 , 2 x 1-1/4 35RE3020012 1.90 2,10 12 24 1.3 ) 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 „:. •q 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 . 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 ra Fig. 35F 3-45°Elbow Size part Number A Packing Weight A L\ '`A in in Inner Master lb >• 1/2 35F 3004 0.88 150 300 0.2 A 3l4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 ±- IA 2 35F 3020 1.69 10 20 1.6 2-1/2 35F3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size J Part Number A Packing Weight TA in in Inner Master lb I 1/2 35T 3004 1.13 80 160 0.3 Il 3/4 35T 3006 1.31 30 60 0.5 . 04 - 1 35T 3010 1.50 25 50 0.7 '7° 1-1/4 35T 3012 1.75 10 20 1.1 A A 1-1/2 351 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL" • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com .sQ i. Ductile Iron Fittings- Class 300 UL/FM Qi Ititry PLUS c ® uS APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size Part Number A Packing Weight `'""^`""' in in Inner Master lb 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 02 -''- 1 35CP3010 1.75 60 120 0 4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling tl Size Part Number A Packing Weight in in lb a i A 1 x 1/2 1 x 3/4 35RC3010004 1.69 80 160 0.3 35RC3010006 1.69 60 120 0.4 0.6 - _ 1-1/4 x 3/4 35RC3012006 2.06 40 Inner Master 80 2 x 1(not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb ■ 11 11), 1 x 1/2 35HB3010004 1.06 180 360 0.2 1x 3/4 35HB3010006 1.06 180 360 0.1 - cIA 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 D 2 x 1 35HB3020010 1.38 40 80 0.6 U 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 C 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 T 1 Fig. 35SP3 -Square Head Plug L E Size Part Number A Packing Weight in in inner Master lb 1/2 35SP3004 0.94 600 1200 0.07 (-JA 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3- Union with Brass Seat A Size A Packing Weight Part Number in in Inner Master lb 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 Ill 'ow., 1-1/2 35U 3014 2.62 10 20 1.7 -1-16-f---- '- 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL" • TOLL FREE 1-800-76b-0076 • FAX(323)890-4456 • www.smithconper.com r e Pipe Hangers Fig.200- "Trim line"Adjustable Band Hanger (B-Line Fig.B317ONF) ®TOLCO Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B311ONFF) c UL us Fig.200C- "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15tr-r)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled --- V swivel nut design permits hanger adjustment after installation. Features: 0-, t , __, • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe ...411. ' , types and protect CPVC plastic pipe from abrasion.Captured design `'! keeps adjusting nut from separating with hanger.Hanger is easily g B - installed around pipe. ® :- A For hanger with non-captured nut order Fig. 200S. " • (21/2" (65mm)thru 8" (200mm))Spring tension on nut holds it securely in ' `. \,,_,--hanger before installation.Adjusting nut is easily removed. ' 1 - i Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) / Fg, th.zooa/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and '✓ Fig.200-1 to 200-2 Fi 200.21/z to 200-8 Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (2oomm)). g' Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, .,,,R Type 10. .2'yti.Th, Maximum Temperature: 650°F(343°C) ,00 Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts • in place of a knurl nut. Order By: Figure number and pipe size P Designed to meet or exceed requirements of FM DS 2-0. µ Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 ,.1" Part No. in. (mm) is (mm) in. (mm) lbs. (kg) "'rep-_ 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4' (20) 3/e"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) 3/8"-16 33/8' (85.7) 25/e' (66.7) 12 (5.5) 200-11/4 11/4 (32) 3/8"-16 33/4 (94.0) 27/8 (73.0) 13 (5.9) 200-11/2 11/2' (40) 3/8"-16 37/8' (98.4) 21/8' (73.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) AI 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/e"-16 57/8" (149.1) 4' (101.6) 29 (13.3) Fig.200S . 200-31/2 31/2' (90) 3/8"-16 73/8' (1873) 51/4' (133.3) 34 (15.6) 200-4 4' (100) 3/8'-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5' (125) 1/2%13 91/8 (231.8) 61/4' (158.7) 66 (30.2) ' 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 13l/8 (333.4) 83/4" (2222) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by E T•N • Threaded Accessories B3205 -Threaded Rod (right-hand threads- both ends) (TOLCO Fig.103) B3205L - Threaded Rod (right& left hand threads) TI. .� Size Range: 3/8"-16 thru 3"-4 rod ! 9� 1�� Material: Steel ,,,. - i Function: Recommended for use as a hanger support in hanger assemblies. � TL �1�-11, Rod is threaded on both ends with right hand threads of the length shown.Also �ll��ll� A available with left and right hand threads-specify Fig.B3205L when ordering. �� s._ Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number,rod size,length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 83205-3/8 x'1' 3/8"-16 21/2" (63.5) 730 (3,25) 572 (2.54) 83205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/6 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (1437) 2530 (11.25) 83205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) 53205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 63205-11/a x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (4225) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) ' B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21/4x'L' 21/4"41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 83205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99- All Threaded Rod Cut To Length Size Range: 3/s"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length It 41) Material: Steel 6 �" I Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. 1 Order By: Part number, rod diameter and finish s Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 991/4"x length 20 240 (1.07) 12 (5.44) ATR 3/s"x 120 99-3/a"x length 16 730 (3.24) 29 (13,15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) • ATR 5I8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) AIR 7/8"x 120 99-7/8"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers&Supports 236 Revised 4.28/2014 by EA•N