Loading...
Specifications RECEIVED MAY 5 2015 STRUCTURAL CALCULA BUILDING-DIVISION D FOR OFFICE COPY GOOD NEIGHBOR CENTER 11130 SW GREENBURG ROAD TIGARD, OR 97223 -- ROOF MECHANICAL REPLACEMENT UNIT -- THE ACTIVATION OF A DUCT \S��� P lu ' ,,,�Fs�/o ACTIVATE A VISIBLE AND 12, j AUDIBLE SUPERVISORY II SIGNAL AT A CONSTANTLY OREG. ATTENDED LOCATION c, OMSC 606.4.1 , ✓0 ✓Ll Y 1 5, ' tiN . NoR��"\ EXPIRES:12/31/16 . CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: 40 OTC: Permit iLte—Zc,/, C)02-6 C'> Addresu jj/SO Cri L,ec1`.0 rt (cb Suite m BY: XIM nts S--;--4 --/S Summary S1 Details A-B D1 -D2 Lateral Calculations L1 -L2 Contact Person: John E Nordling,PE Enclosures El -E3 NORDLING Proj. No.: 15-149 STRUCTURAL GOOD ROOF MECH UNIT CENTER 4, -v � ENGINEERS, LLC COLUMBIA HEATING&COOLING,INC. 6775 SW 111th,Suite 200 Beaverton 012,97008 Date: MAY 2015 By: JEN Sheet No.: COVER SUMMARY 2014 Oregon Structural Specialty Code Wind 120 MPH (3 sec gust, VuLT) Exp B Seismic Occupancy Catagory II Site Class - D Seisimic Design Catagory - D 55 = 0.914 51 = 0.424 SDs = 0.121 SDI = 0.445 There is one roof mounted replacement mechanical unit. weight 800 lbs (including curb) length 6.5' width 3.15' height 3.5' NORDLING Proj. No.: 15-149 GOOD NEIGHBOR CENTER STRUCTURAL ROOF MECH UNIT II 4,4516150 ENGINEERS, LLC COLUMBIA HEATING&COOLING,INC. 6775 SW 111th,Suite 200 Beaverton 012,97008 Date:MAY 2015 By:JEN Sheet No.: S1 II i i i i i i I I II i i i i i II i i i 2 i i ii i i i ., , !i i i i i © i i i - o ii i i I I i i' i i i i i . ii �t_i---i---i�f� � Q II I II I I-W.I I 11 II I i I i i i I I i I -1 H L- L L L- L--I L J- J t- - _1 SLOPED ROOF FLAT ROOF Q EXISTING ROOF MECHANICAL UNIT, TO REMAIN. B NEW ROOF UNIT TO REPLACE EXISTING UNIT. SEE DETAIL (B). NEW UNIT TO WEIGH NO MORE THAN THE EXISTING UNIT. NEW UNIT: CARRIER 4STC04-01, 6.5' x 3.15' x 3.5' TALL ±. MAXIMUM WEIGHT WITH CURB = 800 POUNDS. © FIELD VERIFY THAT THE EXISTING ROOF FRAMING SPANS AS NOTED. THE EXISTING FRAMING IS TO BE OBSERVED FOR �p PROF / CONDITION, FREE OF DECAY. ONCE EXPOSED, REPORT FINDINGS t�� F TO OUR OFFICE FOR REVIEW. PENDING AS-BUILT CONDITIONS, �'G 1 NE UPGRADE MAY BE REQUIRED. Vic, 12,187 ' 9 l 4 OREGON I i.--4) ✓ `ROOF FRAMING PLAN " LF„ 75. \40�ti N • NOR3 I EXPIRES: 12/31/16 NORDLING Proj. No.: 15-149 STRUCTURAL GOOD NEIGHBOR CENTER rc___1 _ ROOF MECH UNIT II ENGINEERS, LLC COLUMBIA HEATING&COOLING,INC. 5775 SW 111th,suite 200'[3eacerton OR,97008 Date:MAY 2015 By:JEN Sheet No.:DI (4) STEEL BRACKETS W/ (4) 1'10 x lip' TEK SCREWS TO CURB d (4) "10 x I�2' rp 411164 WARII TEK SCREWS TO UNIT BASE RAIL ' © MECHANICAL UNIT .—UNIT BASE RAIL (4) "10 SCREWS F______ f-(4) "10 SCREWS _ Lt.__ STEEL BRACKET / — _ J "12 WOOD SCREWS 612' o/c --CURB, FLASHING 4 ROOFING BY OTHERS 4,____--LEVELING CURB (AS REQ'D) II U (E) 2x RAFTER - El 5,,�D PROFF /o S 12,187 r- id DETAIL °G4 ,S. ,.. �0 yN . NOW- EXPIRES: 12/31/16 1---_- NORDLING Proj. No.: 15-149 GOOD NEIGHBOR CENTER STRUCTURAL ROOF MECH UNIT II 415 _ ENGINEERS, L L C COLUMBIA HEATING&COOLING,INC. 6775 SW 111th,Suite 200•Beaverton OR.97008 Date:MAY 2015 By: JEN Sheet No.:D2 ASCE 7.10 Standard Roof Top Meth Unit Location 45°26 23.38"N Ss and Si=Mapped Spectral Acceleration Values 122°46'45.67"W 11130 SW Greenburg Rd,Tigard,OR Ground Motion Ss 0.974 St 0.424 Occupancy Category II Site Coefficients Fa 1.11 Site Class D Fv 1.58 Importance Factor 1.00 Height of Structure 20.0 ft SMS Fa* Ss 1.082 SMt Fv* Si 0.668 Design Category(SDC) D SDS (2/3)SMs 0.721 SDI (2/3)SMt 0.445 Air Side HVAC FP MIN= 0.3 SDS IP WP ap 2.50 r Rp 6.0(1 = 0.216 WP->*0. 0.151 F 0.4•ap •Sps•jp C1+2 Z W FP MAX 1.6 SDSIP WP P= Rp h 1.15 WP->* 0. 0.808 z= 20.0ft ASD _ FP= 0.36 WP->*0.7 0.252 Eq= 0.286W+0.2 SDS W W :Weight of Unit z= 24.0 ft FP= 0.41 WP->* 0.7 0.286 ASCE 7.10 Wind Force Standard Roof TopMcch Unit Wind Speed: 120 mph Exposure : B Height of Structure 20'-0" assume Af<0.1 Bf::Force increase factor x=1.9 qz: 23.24 psf kz: 0.70 Unit Weight 800 lbs Gust: 0.85 Ka: 0.90 Unit Height 33" Cf: 1.30 Kzt: 1.00 Unit Length 74" x: 1.9 Unit Width 47" Curb Height 14" WP: 48.8 psf P: 497 lbs-ASD T= 497 lbs*(14"+33"/2)/47" - 0.6* 800 lbs/2 = 82 lbs Net Uplift NORDLING Proj. No.: 15-149 STRUCTURAL GOOD NEIGHBOR CENTER ROOF MECH UNIT II ENGINEERS, LLC COLUMBIA HEATING&COOLING,INC. 6775 SW 111th.Suite 200•Beaverton OR.97008 Date:MAY 2015 By:JEN Sheet No.: L1 . , i V EQ : 113 Ibs ,>1-. W: 11111111111111111k1 800 lbs Height 33" Weight 800 lbs Length 74" ;At' A11141:41141 Width 47" Curb 14" VEQ= 0.286* 800 lbs+0.2* 0.721 * 800 lbs VEQ = 2291bs+115lbs 224 lbs �' T= 229 lbs *(14"+33"/2)/47" + 115 lbs/2 G: 38 lbs - 0.6* 8001bs/2 = -34 lbs [0 Net Uplift] V= 229 lbs (4) STEEL BRACKETS W/ (4) "10 x I/2' TEK SCREWS TO ROOF CURB d (4) "10 x 1/2' TEK SCREWS TO UNIT BASE RAIL -01c.- *12 612' o/c SCREWS FROM CURB TO FRAMING BELOW. -ok- NORDLING Proj. No.: 15-149 GOOD NEIGHBOR CENTER n----- STRUCTURAL ROOF MECH UNIT II ENGINEERS, LLC COLUMBIA HEATING&COOLING,INC. 6775 SW 111th,Suite 200 Beaverton OR,97008 Date:MAY 2015 By:JEN Sheet No.:L2 CERTIFIED DIMENSION 48TC04-07 NOTES: 4gt UNITED P.O.ac MO Till O CONLAT IS Ile li![moss OSIER 01 ATIN ,miss 1 a THREE uulpt p NOCpN r{ TECHNOLOGIES nNACNEE.IT CRNRNn nu S7 HR nl<laro a SEN nr.sur CSP¢N KO N I IONITITurE PAST n.rfUAHR[w 1. DIMENSIONS ARE IN INCHES, DIMENSIONS UNIT J N CARRIER 14811 f.0.0.no.•s M inn OMIT. ACCaTAHR[Or 1WINAAI. IN f 1 ARE IN MILLIMETERS. /81[-401 33 318 "SIB 2. 19 CENTER OF GRAVITY [8171 11121 CONNECTION SIZES 481C-A05 33 318 1/Ile [8111 13111 A 13/8'1351 DIA FIELD POWER SUPPLY HOLE 3.y DIRECTION Of AIR FLOW 481C-A06 33 311 1/118 'CD 1' [501 OIA P00(1 SUPPLY KNOCRWT [8111 [3111 187E-ADi /1 318 1/7/8 I JIP{511 DIA GAUGE ACCESS PLUG [IOSII [3111 1/1•[211 OIA FIELD CONTROL WIRING MOLE ` 33.3/8 18181 E 7/1•-11 NPT CONDENSATE DRAIN F 1/2•-11 APT GAS CONNECTION . r G 2 Ill' 1611 DIA POWER SUPPLY KNOCKOUT 72-1/4 r ECONOMIZER HOOD 16 10181 IOPTIONAII 14061 • -TM-THE•BASE CHART FILTER ACCESS PANEL I THESE HOLES REQUIRED FOR USE (TOOL-LESS] CORP. CONDENSER THESE HOLED REQUIRED 003401 • ACCESS I COIL _ •PANEL .- .. _5--- I THREADED WIRE AEO'D HOLE INDOOR COIL er 1 , ,�P. CONDUIT SIZE USE SIZES I440.1 ACCESS PANEL I ? F— M 112' ACC. 110'121.11 25.8/8 ID-1/B % 112' 241 1/1'122.21 O („1I Fr �\� (6521 11771 T. 3/1 1001,0031 POWER 1 1/0'F21.11 _ y4 RETURN AIR RETURN Z•• 10031 •FPT GAS 1 7116' [30.01 y1691.)•l�is��BS�ria€1 11 y Ill” 1`\ �� �, .. - . AIR 1121 it 111\�V ���•=_ '�� f FOR'TNRU-TAE-BASEPAN•FACTORY OPTION. 2518 I \ ��� �-�-�--1� _ FITTINGS FOR 0411 E R. 1 2 ARE PROVIDED BACK [611 ��� 7 TYP SELECT EITHER 3/A'OR 1/2• �?W CONDENSATE I FOR POWER, DEPENDING ON WIPE SIZE CURB I 17-J// WIDTH I ] `% DRAIN OPENING 11311 •, !0011 PROVIDES 711•FPT THRU LURE 1 1 '1 IN BASEPAM SUPPLY 26;112. 29-3/0 SUPPLY FLANGE 1 FITTING. 18-I/8 AIR [bAIA [4591 1 16.1/1 // !1 11.1 12-1 ` (1111 17631 [3121 SEBASERCXA0.T [ 1I 1511 •\ = /B —.. 12-1/1 •-•-r-J-][851 110 [3011 25 LUE [6361 (1001 HOOD p.--18-1/2-� N TOP 11101 IO-112 1-111 4-5/8 11181 [2651 1321 LECTRICAL •II I I DISCONNECT •• .� • - �"'—� '-7 LOCATION• CONDENSER III CONTROL 80% ACCESS BLOWER E STD. ALTER COAL A, ACCESS PANEL ACCESS CONDENSATE •B, DRAIN G 15-1/6 �� • [6311 OUTSIDE OPTIONAL I li-3// AETUAN AIR E INSTALLED I. 19-I/2 �ACTOAT �.T ,,,------IIIIIIAMOLE II-3/8 I, SUPPLTIAI0.1 AIR 1 COMYENIEN[E II [1911 INSTALLED / / .[2891 I, . OUTLET DISCONNECT 1±.,......v-HANDLE 21.1/1 L �,_ - 15311 11681 �1 11158 ��� ��� 6-SIB ��O(] •� •I� ti�•. (](].L' 11551 3-1N HANDLE _A-Sf8 6-5/8 7 6 [951 16•311 30-1/0 12131 11681 11111 11521 [11811 11611 26-3/1 71•718 16811 BAROMETRIC [18881 11-1/4 RELIEF • 11931 FLOW SUPPLY RETURN LEFT FRONT AIR `'' RIGHT "EP SKEET RAE UuraClu8 48TC 04-07 SINGLE ZONE ELECTRICAL "n I OF 2 11-24-08 09-29-08 COOLING WITH GAS HEAT 481M500993 5. 0 C08023 • clI 48TC 48TC CERTIFIED DIMINSION 48TC04-07 UNITED R.O.IW 1111 1x15 00(3x111 15 iK 3111(11,11 CCRR[u 00301311M 141 311311 Or rx[Sl 0,3111 OR 10Nx[xr( TECHNOLOGIES 13138463.11 0 rs 0nnn[e UPON TK EIIKS(WIIII103 1x11 la OO[S 101 001 rK1St 11111 0 05 10(31 OR SID. UNIT CORNER CORNER CORNER CORNER C.G. HEIGHT CARRIER 15221 COMAAT nu ror TE 0uT[0n003lSU 11110410111131 ACCEPT/ACE Or COMEACT. UNtT e[IGNT v[IGxT[A7 BEIGNT IBl vEIGHi ICI vEIGXi 1D1 caKralna•s Km[1 c11suT. LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. 1 T 2 481C-A04 183 219 Ill 50 125 57 131 51 116 53 39 19111 23 15811 16 3/8 11161 411C-A05 531 244 124 56 139 _63 145 66 129 59 31 11111 23 15841 17 11321 481C•508 569 258 131 51 141 67 154 10 131 62 31 11911 23(5811 17 1/1 11381 48TC•801 652 296 ISO 88 169 16 176 80 157 II 39 11111_23 15841 20 1/8 15111 CORNER A CORNER B -rte•., 0 I, 1 1 1 1 I 1 1 7 e•1pn,1.,;;, . I • • CORNER D 112 ---� CORNER C TOP • a FRONT • SKEET 411E SIKK[O[1 48TC 04-07 SINGLE ZONE ELECTRICAL 1(R 48T0500993 zooz 11-24-08 09-29-08 COOLING WITH GAS HEAT 5. 0, C08024 (V‘ 1 v ROOF CURB DETAILS CONNECTOR D ALT ACCESSORY ROOFCURB PKG.AGCY. B C DRAIN GAS POWER CONTROL POWER ACCESSORY A UNIT SIZE HOLE CRBTMPWROO1A01 3/4" [19] 1'-2" 1'-91/16" 1'-4" 13/4" NPT 3/" [19] 1/2' [12.7] 1/2" [12.7] CRRFCURB001A01 [356] 48TC [551] [406] [44.5] 1/2" [127] NPT NPT NPT CRRFCUR6002A01 2.-0" A04-A07 CRBTMP W R003A01 NPT [610] NOTES: 1. Roof curb accessory is shipped disassembled. 2. Insulated panels. C 3. Dimensions in[ ]are in millimeters. -) 4. Roof curb:galvanized steel. \ I / 5. Attach ductwork to curb(flanges of duct rest on curb). -al.,, ,s,� 6. Service clearance:4 ft on each side. C �` 7. .\\\�•Direction of airflow. ..„),A...' __` 8. Connector package CRBTMPWRO01A01 is for 1 s� 1 thru-the-curb type gas. ` (-I --; CRBTMPWR003A01 is for thru-the-base type . / I / ruN1r gas connections. () ( F- e, /l NAIL -•- 0 GASKET 0'-0 1/4" �' E761 !, (SUPPLIED WITH CURB) . TYPICAL (4) SIDES (6.31 . .. . . _ - - -, (F IELD 9UPPL I ELD .57,/316. COUNTER SUPPLIED) .-. (..__ - ROOFING FELT • (FIELD SUPPLIED) 8 CANT STRIP 176) (FIELD SUPPLIED) RETURN AIR 1, ] O OPENII(ING 2.140318• \\_ r(F�ELO SUP 1IFO SECTION'4C-C- •('-1�/10" I BOPENING C \\\\\\\\\\ 1341] \ I I P--. � -- _-- /i -� RIGID INSULATION 0'-0 7/16' H L1'1 / (FIELD SUPPLIED) 111] _J."-7 13/16" 1/8"_ O'-0 7/16" (80LT HEADS) )504) [334] [111 0'-3' (BOLT HEADS) I 176) / OPENING FOR BASEPAN ENTRY 0'-0 7/16' 0'-0 7/I6' / SERVICE (SEE NOTE 4B) 7/I1 8; [914) [ill 11 / 0'-2 1/2' A (BOLT MEADS) BOLT HEADS){A [641 II / . _ .. I _. _._. .. . / CB31 441 ' (2307 / •1 SEE NOTE•2 I • 4 /'-4 3/16 • • [106) ' I I / GAS SERVICE / PLATE , (SEE NOTE•8) / 1'-4 13/16' O'-0)/4'[77 / [427) ,'-8' (INSIDE) [1527 14� O .4 /�(INSIDE) 0'-7 1/16- [179] 0'-4 9/16' 6` ! { I (INS10E) (115.5] I {{ I TYP 0 i "f ! SUPPLY AIR RETURN AIR S .\ 2 3/8' , VIEW "A-A" •.:., ` HEAD OF BOLT TO BE ON `� ` 1.110. INSIDE OF FLANGE #„../...7..' ' \�, 0'-1 7/8' / „,,,,%.,,,� �48] ` 1( [1705] I3'-0 15/16' NOTE1 CAMBRIDGEPORT SURE-LOCK'CORNER AREF ' I p�-y. C9381 , / ALTERNATE DEVICE ACCEPTABLE ' [761 VIEW "B" I�". ' (TOP. ALL CORNERS) SEE VIEW "8" C07503 7 ��