Report f t3 z41+ 000 a 0 � —101 Sw d P RFD FIRE SPRINKLER MAY 21 2014 CITYOF r1GARD Product Data For: BUILDIN(4rWltSIO Bridgeport Village Pizzasmith 7331 SW Bridgeport Rd Tigard, OR 97224 PREPARED BY: rt FIRE PROTECTION Viking Automatic Sprinkler Co. 3245 NW Front Avenue Portland, OR 97210 24 Hrs. 0: 503.227.1171 F: 503.227.1552 OR CCB #64837 • Metro Lic #2816 • WA LIC #VI-KI-NA-5373NT Boise • Longview • Medford • Portland • Seattle Submittal Date: May 20, 2014 TABLE OF CONTENTS SECTION#1 — Sprinkler Heads A. Viking, Concealed Pend, VK 462 B. Viking, Upright, VK 100 C. Viking, Dry Pend, VK 154 D. Viking, Horizontal Sidewall, VK 116 January 27, 2012 Sprinkler 54a NIKING® MIRAGE" STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION Viking Mirage' Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. -- ` The sprinkler is pre-assembled with a threaded adapter for installation with a low-pro- file cover assembly that provides up to 1/2" (12.7 mm) of vertical adjustment.The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate.The"push-on", "thread-off' design of the concealed cover plate assembly .- allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS c Ous cULus Listed: Category VNIV FM FM Approval: Class 2015 VdS NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPC LPCB Approved: Ref. No. 096e/12 (E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 Refer to Approval Chart 1 on page 54c and Design Criteria on page 54d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 54e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to-65°F (-55°C) Patents Pending °cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Viking Technical Data may be found on Phosphor Bronze UNS-C51000 for Sprinkler VK463 The Viking Corporation's Web site at Deflector Pins: Stainless Steel Alloy http://www.vikinggroupinc.com. Bulb: Glass, nominal 3 mm diameter The Web site may include a more recent Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel edition of this Technical Data Page. UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-C51000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 Replaces page 54a-f, dated April 8, 2011. (Revised VdS Approval.) Sprinkler 54b January 27, 2012 R MIRAGE STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage" Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E For example, sprinkler VK463 with a 155 °F (68 °C) temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504(2-3/4"diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate. 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper= E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black= M-/B Temperature Suffix: 135 °F (57 °C) UL(139 °F (59°C) FM and LPCB) =A, 165 °F (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 °F (74 °C)temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135°F (57 °C)temperature rated cover plate only Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 14047W/B (available since 2006), or B. Head Cabinet Wrench Part No, 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a '/2" ratchet(not available from Viking). ** Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. - January 27, 2012 Sprinkler 54c iuNG® MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Temperature Rating of Cover Classification Temperature.Rating' Ceiling Temperature' Assembly (Required) Bulb Color 135 °F (57 °C) cULus Ordinary 155 °F (68° C) 100 °F (38 °C) 139 °F (59 °C) FM and LPCB Red Intermediate 175 °F (79 °C) 150 °F (65 °C) 165 °F (74 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) 165 °F (74 °C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes 'The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Approval Chart 1 (UL) "Cover Plate Temperature Rating 1 --Cover Plate Temperature Rating Mirage®Concealed Pendent Sprinklers VK462 and VK463 AW14-Cover Plate Finish KEY NPT Thread Nominal Maximum Listings and Approvals° Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria on page 54d.) Base Part No.' Inch mm U.S. metric Pressure cULus5 NYC VdS' LPCB CE Standard Response Applications 13503A VK462 1/2" 15 _ 5.6 80.6 175 psi(12 bar) — — AY1, CZ1 AY1, BZ1 AY1, CZ16 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1. BX1 AV1, BW16 — — — 13667A VK463 1/2" 15 5.6 80.6 250 psi (17.2 bar)' AV1, BX1 AV1, BW16 — — — Cover Plate Assembly Temperature Ratings9 Cover Plate Assembly Finishes10 Sprinkler Temperature Ratings V- 135 °F (57 °C) cULus Listed cover 13504', 13642' (large diam- 1 - Polished Chrome,Brushed Chrome, eter), or 15394' (square cover plate) A-155°F(68°C) W-165°F(74 °C)cover 135041 or 13642' (large diameter) Bright Brass, Antique Brass, B-175°F(79°C)and 200°F(93°C) X-165°F(74°C)cover 135041, or 136421 (large diameter) Brushed Brass, Brushed Copper, C-200 °F(93°C) Y- 135°F(57°C)cover 13504' LPCB Approved as 139 °F(59 °C) Painted White, Painted Ivory, or Z-165°F(74°C)cover 13504' Painted Black Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'The Water Working Pressure rating is stamped on the deflector. °This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S.and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E,Vol. 32. 'VdS Approved,standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999+A1:2001 +A2:2004+A3:2006,Certificate G4080021. °CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 'The 135/139°F cover has an orange label.The 165°F(74°C) cover has a white label. i0Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. • Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Sprinkler 54d January 27, 2012 MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com DESIGN CRITERIA--'UL (Also refer to Approval Chart 1 on page 54c.) cULus Listing Requirements: Mirages Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard, Group II. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Approval Reauirements: a)The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. b)This sprinkler is deflector fixed type and can be only activated by heat.The housing is not tight. c)Follow installation guidelines of current standards, CEA4001VdS and EN12845.These sprinklers can only be installed in LH and OH occupan- cies, except in OH4. NOTES: Due to the design the sprinkler type 'Domed-CCP'shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type 'Domed-CCP'shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. 4. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 or QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. • CUSTD ,j \' ,6 DO NOT PAINT Z cr o n — O VIKING �o Identification of Custom Paint Color: All custom color painted cover plates will have on identifying label affixed to the inside of the cover that indicates custom color and will have a representative sample -3-5/16" (84.1 nrl)-111N- (a paint dot) of the paint on the label, Figure 1: Identification of Custom Paint Color for Concealed Covers Figure 2: Square Cover Assembly 15394 January 27, 2012 Sprinkler 54e NlluNG. MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 2 (FM) -^Sprinkler Temperature Rating • ,`�--Cover Plate Temperature Rating Miragee Standard Response Concealed Pendent Sprinkler VK462 I AW1t Cover Plate Finish KEY Maximum Sprinkler Base NPT Thread Size Nominal K-Factor FM Approvals' Part No.' SIN Water Working (Refer also to Design Criteria below.) Inch mm U.S. metric' Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AW1,BX1 Cover Plate Assembly Temperature Ratings' Cover Plate Assembly Finishes' Sprinkler Temperature Ratings W- 139 °F (59 °C) cover 13504', 13642' (large diameter), 1 - Polished Chrome, Brushed Chrome, Bright A- 155°F(68°C) or 15394' (square cover plate) Brass, Antique Brass, Brushed Brass, B-175°F(79°C)and 200°F(93°C) X-165°F(74°C)cover 13504', 13642'(large diameter),or Brushed Copper, Painted White, Painted 15394' (square cover plate) Ivory, or Painted Black Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This chart shows the FM Approvals available at the time of printing. Other approvals may be in process.Check with the manufacturer for any additional approvals. The 139 T(59°C)cover has an orange label.The 165 °F(74°C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. ' Sprinkler 54f January 27, 2012 MIRAGES STANDARD AND • VIKING® TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Mil Sprinkler Wrench = Sprinkler III Ii Flat 2-1/4' (57.2 mm) Frame I,II� diameter opening Arms _ is required in -I�`'`10",I ��! the ceiling, — �_ ���-�ilr Sprinkler and �r!!�_—. 7-A-dapter Assembly — ! Bali (Protective Cap 1 is removed for _ Q Installation--use III Wrench 14031**) NEVER install the sprinkler by applying the installation Sprinkler wrench across the frame arms. Wrench — CPnrt No. DO NOT overtighten. 14047W/Bsw J Use only the designated is shown) 1 sprinkler wrench, Viking Part 1 Number 14047W/B or 14031. - **A 1/2' ratchet is required (not 1 t DO NOT apply more than f— ;=; available from Viking). 25 ft. lbs. of torque. A leak tight seal should be achieved Step 2: Carefully press the by turning the sprinkler Step 1: Carefully slide the wrench upward and turn slightly clockwise 1 to 1-1/2 turns wrench sideways around to ensure engagement with the beyond finger tight. the deflector and pins. sprinkler wrench flats. Figure 3: Sprinkler Installation and Correct Use of Wrenches - 1/2' (15 mm) NPT \ — 4 ■t ___—_-- 4 _ 2-9/16' ____ 2-1/16' 2-3/16' ��� (65 mm) (52 mm) 11011 (55 mm) Maximum l Minimum r. —t•∎ - 'ZEII::::::::::15 2-3/4' (70 mm) or 3-5/16' (84.1 mm) Note: Upon sprinkler activation, the deflector descends - to approximately 13/16' (20.6 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 Replaces page 54a-f, dated April 8, 2011. (Revised VdS Approval.) June 28, 2013 Sprinkler 11q\HIKING® MICROMATICT'AND TECHNICAL DATA MicromaticHP STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION _ Viking Micromati& and MicromaticHP°S Standard Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature rat- i- ings, and K-Factors to meet design requirements. The special Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings • can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres �:—�_ and are listed/approved as corrosion resistant as indicated in the Approvals> •+ Chart. (Note: FM Global approves the ENT coating as corrosion resistant. FM "-� Global has no approval classification for PTFE and Polyester coatings as corro- — sion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprin- klers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page 11r. 2. LISTINGS AND APPROVALS cOus cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, and 2016 NYC Approved: MEA 89-92-E, Volumes 3 and 12 vds] ABS Certified: Certificate 04-HS407984B-PDA VdS Approved: Certificates G4060055, G4980001, G4980003, G4980004, G4980006, and G4980008 PCB LPC Approved: Ref. No. 096e/06 (E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40137, Q 0786-CPD-40142, 0786-CPD-40177, and 0786-CPD-40182 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on pages 11t-u for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 11v for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1997. Viking Technical Data may be found on Minimum Operating Pressure: 7 psi (0.5 bar)" The Viking Corporation's Web site at Maximum Working Pressure: Sprinklers VK021 and VK124 are rated for http://www.vikinggroupinc.com. use with water working pressures ranging from the minimum 7 psi The Web site may include a more recent (0.5 bar) up to 250 psi (17 bar)for high-pressure systems. High-pres- edition of this Technical Data Page. sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: Refer to the Approval Charts 'cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 09993, 12986, 10227, and 10233. Brass UNS-C84400 for all other sprinklers. Form No. F_080106 Replaces page 11q-v, dated June 11, 2013. (ENT finish is now approved as corrosion resistant.) ' Sprinkler 11r June 28, 2013 MICROMATIC°AND TECHNICAL DATA MicromaticHP° STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 12986 and 12993.Copper UNS-C19500 for Sprinklers 10141, 10169, 10174, 10220, and 10233. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 09995, 10191, 10192, 10218, and 10219): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap for Sprinkler 09993: Brass UNS-C31400 or UNS-C31600. Pip Cap and Insert Assembly for all other Sprinklers: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment(for Sprinklers 09995, 10192, and 10218): Brass UNS-C36000 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap-ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® and MicromaticHP® Standard Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, and Black PTFE = N, Wax Coated = C, Wax Over Polyester=V-/W, ENT= JN Temperature Suffix (°F/°C): 135°168°=A, 155°/68° = B, 175°/79° = D, 200°/93° = E, 212°/100° = M, 286°/141° = G, 360°/182° = H, 500°/260° =L, OPEN=Z (PTFE only). For example, sprinkler VK100 with a 1/2"thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12986AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000) B. Wrench for wax-coated sprinklers: Part No. 13577W/B**(available since 2006) —A1/2"ratchet is required(not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B.Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Micromatic° and MicromaticHP° Standard Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. June 28, 2013 Sprinkler 11s MICROMATIC(9 AND TECHNICAL DATA MicromaticHP ' STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature -Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green Intermediate 212 °F (100 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Extra High 360 °F (182 °C) 300 °F (149 °C) Mauve Ultra High' 500 °F (260 °C) 465 °F (240 °C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings`: White Polyester, Black Polyester,and Black PTFE in all temperature ratings. ENT in all tempurature ratings except 135 °F (57 °C). Wax-Coated Brass and Wax over Polyesters for sprinklers with the following temperature ratings: 135 °F (57 °C) Off-White Wax 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 212 °F (100 °C) Dk. Brown Wax6 286 °F (141 °C) Dk. Brown Wax6 Footnotes The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300 °F (149°C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), response time may be severely retarded. 'The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester,ENT,and PTFE coatings. For PTFE coated open sprinklers only,the waterway is coated. For ENT coated sprinklers, the waterway is coated. Wax Over Polyester is unavailable for Sprinklers VK021 and VK124. 'Wax melting point is 170°F(76 °C)for 212°F (100°C) and 286°F (141 °C)temperature rated sprinklers. Wrench Protective Sprinkler Cap Flat li w�►°�il 10896 m)) Figure 1: Standard Sprinkler Wrench 10896W/B • - Sprinkler 11t June 28, 2013 R: MICROMATIC®AND TECHNICAL DATA MicromaticHP® STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 1 (UL) Temperature KEY Micromatic®and MicromaticHP'Standard Response Upright and Conventional Sprinklers 1 Finish Al X4--Escutcheon(if applicable) Maximum 175 PSI (12 bar)WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals' Number' SIN (Refer also to Design Criteria on page 11u.) , NPT I BSP U.S. I metric' Inches I mm cULus4 NYC' j VdS I LPCB I (E"I (J" Upright-Standard Orifice 12986 _ VK100 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B4, C5, D3, F6 See Footnote 7. — 10233 VK145 1/2" 15 mm 5.6 80.6 2-3/16 56 — — A2 A2, B4 A2 E2 10174 VK145 — 15 mm 5.6 80.6 2-3/16 56 — — A2 A2, B4 — — 12993 VK100 — _15 mm 5.6 _ 80.6 2-3/16 56 Al, B4, C5, D3, F6,_Al, B4, C5 — — — — Upright-Large Orifice 10220" VK200 1/2" 15 mm 8.0 115.2 2-3/8 60 Al, B4, C5, D3, F6 Al, B4 A2 — E3 E3 10141 VK200 3/4" 20 mm _ 8.0 115.2 2-5/16 59 Al, 64, C5, D3, F6, Al. B4, C5 A2 A2 E3 E3 10169 VK200 — 20 mm 8.0 115.2 2-5/16 59 Al, B4, C5, D3, F6 — A2 A2 E3 E3 Upright-Small Orifice' 1021810 VK001 1/2" 15 mm 2.8 . 40.3 2-3/16 56 Al, B4, C5 See Footnote 7. — _ _ _ 1021910 VK002 1/2" 15 mm 4.2 57 2-3/16 56 Al B4, C5 See Footnote 7. — _ — _ 1019110 VK002 — 15 mm 4.2 57 2-3/16 56 Al, B4, C5 — — — _ _ 1019210 VK001 — _15 mm 2.8 40.3 2-3/16 56 Al, B4, C5 — — — — ' — Conventional-Standard Orifice 10227 VK118 1/2" 15 mm 5.6 _ 80.6 2-3/16 56 . Al, B4 Al, B4 A2 A2, B4 A2 E2 10172" VK118 — 15 mm 5.6 80.6 2-3/16 56 Al, B4 — — A2, B4 — — Conventional-Large Orifice 10228 VK120 3/4" 20 mm 8.0 115.2 2-5/16 59 Al, B4 Al, B4 A2 A2 E3 E2 . 1016811 _VK120 — 20 mm_ 8.0 115.2 , 2-5/16 59 Al, B4 — A2 A2 ' E3 _ E3 Maximum 250 PSI (17 bar)WWP Upright-Standard Orifice 09993 I VK124 I 1/2" 115 mm I 5.6 I 80.6 2-1/4 I 58 I Al, D3 I See Footnote 7. I — — _ _ Upright-Small Orifice' 099959 I VK021 1 1/2" 115 mm I 2.8 I 40.3 I 2-1/4 I 58 I Al I See Footnote 7. I — I — 1 — I — Approved Temperature Ratings A- 135 °F (57 °C), 155 °F (68 °C), 175 °F(79 °C),200 °F (93 °C), 286 °F Approved Finishes (141 °C), and 360°F(182 °C) 1 -Brass, Chrome,White Polyester`', Black Polyester', and Black PTFE' B-135°F(57 °C), 155°F(68 °C), 175°F(79 °C), and 200°F(93 °C) 2-Brass, Chrome,White Polyester, and Black Polyester C-286°F(141 °C) 3-Brass and Chrome D-500°F(260 °C)6 4-Wax-Coated Brass and Wax over Polyesters E- 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 5-200 °F (93 °C) High-Temperature Wax Coating (corrosion resistant); 360 °F (182 °C) maximum ambient temperature allowed at ceiling= 150 °F (65 °C) F- 155 °F (68°C), 175°F(79 °C), 200°F(93 °C), 286 °F(141 °C), 360 °F 6-ENT' (182 °C), and 500°F(260 °C)0 Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 'Listed by Underwriters Laboratories Inc.for use in the U.S. and Canada. 5 cULus Listed as corrosion resistant. 6 Upright sprinklers Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E,Vol. 12. Conventional sprinklers accepted for use.City of New York Department of Buildings, MEA Number 89-92-E,Vol. 3. 'Meets New York City requirements, effective July 1,2008. 'Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet systems only.Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 10The sprinkler orifice is bushed. "Sprinklers 10168 and 10172 are available on special order. 12((Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40137, 0786-CPD-40142, 0786-CPD-40177, 0786-CPD-40182, 0832- CPD-2001, and 0832-CPD-2003. '3 O MED Certified, Standard EN 12259-1,EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. "The 1/2"NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. - • June 28, 2013 Sprinkler 11u MICROMATIC®AND TECHNICAL DATA MicromaticHP® STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com DESIGN CRITERIA- UL (Also refer to Approval Chart 1 on page 11t) cULus Listina Reauirements: Micromatice and MicromaticHP°Standard Response Upright and Conventional Sprinklers are cULus Listed as indicated in the Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style(conventional)sprinklers. • Designed for use in Light, Ordinary, and Extra Hazard occupancies. (Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized.) • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed.For conventional sprinklers, refer to the installation guidelines for old style(conventional)sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Sprinkler Wrench 13577W/B** must be used for installing wax coated sprinklers Step 1: Carefully slide the wrench sideways around the deflector, ensuring engagement •:,• .,�-�,. with the sprinkler r w- wrench flats. / rt _Olt It s II/ ��I NiK�ir Ill J Wax Coated / C Upright Sprinkler w*A 1/2' ratchet is required Step 2: Carefully press the wrench (not available from Viking). downward and ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 13577W/B for Wax Coated Sprinklers Sprinkler 11v June 28, 2013 NIKING C MICROMATIC®AND TECHNICAL DATA MicromaticHP® STANDARD RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 2 (FM) Temperature KEY Micromatic�Standard Response Upright Sprinklers l��Finish AiX 4—Escutcheon(if applicable) Maximum:175 PSI (12 bar)WWP Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals' Number' I NPT BSP U.S. metric2 I Inches mm (Refer also to Design Criteria below.) Standard Orifice 12986 VK100 1/2" 15 mm 5.6 80.6 2-3/16 56 _ Al, C5, E6, Fl, G4, H7 10233 VK145 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, D2, E6, Fl 10174 VK145 — 15 mm 5.6 80.6 2-3/16 56 Al, D2, Fl 12993 VK100 — 15 mm 5.6 80.6 2-3/16 56 Al, D2, Fl, G4, H7 Large Orifice 10220' VK200 1/2" 15 mm 8.0 115.2 2-3/8 60 B1, D5, Fl, H7 10141 ' VK200 3/4" 20 mm 8.0 115.2 2-5/16 59 B1, D5, Fl, H7 10169 VK200 — 20 mm 8.0 115.2 _ 2-5/16 59 B1, D5, Fl, H7 Small Orifice' 102186 VK001 112" 15 mm _ 2.8 40.3 2-3/16 56 D3, D5 - 101926 VK001 — 15 mm 2.8 40.3 2-3/16 56 D3, 05 Approved Temperature Ratings A-135°F(57°C), 155 T (68 °C), 175°F(79°C), 200°F(93°C), 212 °F(100°C), Approved Finishes 286°F(141 °C), and 360°F(182°C) 1 -Brass, Chrome,White Polyester, and Black Polyester B-135°F(57°C), 155 °F(68 °C), 175°F(79°C), 200°F(93°C), 286°F(141 °C), 2-White Polyester and Wax-Coated Brass(corrosion resistant) and 360°F(182 °C) 3-Brass and Chrome C-135°F(57°C), 155°F(68°C), 175°F(79°C),200°F(93°C),and 212°F(100°C) 4-Wax-Coated Brass and Wax over Polyester D- 135°F(57°C), 155 °F (68°C), 175°F(79°C), and 200°F(93 °C) 5-Wax-Coated Brass(corrosion resistant) E-286°F(141 °C) 6 - 200 °F (93 °C) High-Temperature Wax Coating (corrosion F-500°F(260 °C)5 resistant); maximum ambient temperature allowed at ceiling G- 155°F(68°C) = 150 °F(65°C) H-155°F(68°C), 175°F(79°C),200°F(93°C),286 °F (141 °C), 360 T (182 °C), 7-ENT' 500°F(260 °C)5 Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. ' FM Approved as standard response Non-Storage upright sprinklers. For specific application and installation requirements, reference the latest ap- plicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). 5 Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above 300°F(149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. The sprinkler orifice is bushed. 'The 112" NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. r FM approved as corrosion resistant. DESIGN CRITERIA- FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: The sprinklers indicated in Approval Chart 2 are FM Approved as standard response Non-Storage upright sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet - 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699- Care and Handling of Sprinklers.Also refer to page SR1-3 for gen- eral care, installation, and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_080106 Replaces page 11q-v, dated June 11, 2013. (ENT finish is now approved as corrosion resistant.) February 26, 2014 Sprinkler 101a N KING® STANDARD RESPONSE TECHNICAL DATA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION Viking Standard Response Dry Pendent Sprinklers are thermosensitive spray sprin- klers suitable for use in areas subject to freezing.The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or conden- sation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Standard Response Dry Pendent Sprinklers are available in x' • various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been in- vestigated for installation in corrosive atmospheres and are listed/approved as corro- sion resistant as indicated in the approval charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) NOTE: When installed in some corrosive environments, the Polyester finish 8 may change color. This natural discoloration over time is not in itself an indi- cation of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. 2. LISTINGS AND APPROVALS �� us cULus Listed: Category VNIV FM FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E, Volume 37 LPCB Approved: Ref. No. 096e/06 C E O CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 0 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 101d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 101f for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1991. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**)for all listed and approved lengths. Glass-bulb fluid temperature rated to-65 °F (-55 °C) * cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). **Metric K-factor measurement shown is when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 5 mm diameter Viking Technical Data may be found on Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with The Viking Corporation's Web site at PTFE Tape http://www.vikinggroupinc.com. Compression Screw: Brass UNS-C36000 The Web site may include a more recent Pip Cap: Brass UNS-C31400 or UNS-C31600 edition of this Technical Data Page. Pip Cap Adapter: Brass UNS-C36000 Seat (for Sprinklers VK151, VK155, and VK159 only): Copper UNS-C21000 Orifice: Copper UNS-C22000 or UNS-C11000 (Copper UNS-C21000 for Sprinklers VK151, VK155, and VK159) Form No. F_071591 Replaces page 101a-g, dated July 17, 2013. (Removed Seal Part Number.) • Sprinkler 101 b February 26, 2014 NIKING® STANDARD RESPONSE TECHNICAL DATA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Gasket (for Sprinklers VK151, VK155, and VK159 only): Buna-N Tube: ERW Hydraulic Steel Tube Barrel End and Threads (for Sprinklers VK150, VK154, and VK158): QM Brass Support(Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Order Standard Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A" dimension)to sprinkler base part number. Order in a specific length noted as the"A"dimension (see Figures 3 through 5).The"A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2"to 45-1/2"(38.1 to 1,156 mm)for the adjustable standard style, 3"to 47" (76.2 to 1,194 mm)for the plain barrel style, and 3-1/4"to 47-1/2" (82.5 to 1,207 mm)for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a "made-to-order" basis: Recessed Dry Pendent up to 65-1/2" (1,664 mm).Adjustable Standard Dry Pendent up to 63-1/2" (1,613 mm). Plain Barrel Dry Pendent up to 65" (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass=A, Chrome= F,White Polyester= M-/W, and ENT= JN Temperature Suffix(°F/°C): 155°/68° = B, 175°/79° = D, 200°/93° = E, 286"/141° = G For example, sprinkler VK154 with 1" NPT Threads, a Chrome finish and a 155 °F/68 °C temperature rating, and"A" length of 10" =Part No. 07740UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Wrench Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking Flat data book.) Protective Sprinkler Wrenches: Sprinkler A. Standard Wrench: Part No. 07297W/B (available since 1991) 0 Shield B.Wrench for recessed sprinklers: Part No.07565W/Bt(available since 1991) hi tA'A"ratchet is required (not available from Viking).Sprinkler Guard: Chrome,with no listings or approvals, for installation on dry pendent sprinklers manufactured after May 1994 only(Part No.08954). Replacement Escutcheons: A.Adjustable Standard Dry Escutcheon: Base Part No. 07741 VIKING "297 Q�) B. Recessed Dry Escutcheon Cup: Base Part No. 05459A , 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Figure 1: Standard Sprinkler Wrench 07297W/B 5. OPERATION During fire conditions,the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Standard Response Dry Pendent Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. February 26, 2014 Sprinkler 101c - NIKING® STANDARD RESPONSE TECHNICAL DATA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 155 °F (68 °C) 100 °F (38 "C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 "F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating34: White Polyester and ENT in all temperature ratings Footnotes 'The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13. Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Note:These coatings are NOT cor- rosion proof. Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. When installed in some corrosive environments,the Polyester finish may change color.This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. 7-7 :m 1 1' Wrench 07565W/B** -' must be used for - -�', _ _ .. installing recessed '. dry sprinklers ' Step 2: Carefully press Step 1: Carefully — w*A 1/2' ratchet the wrench upward and slide the wrench is required (not ■ ! turn slightly to ensure sideways around the available from Viking). engagement with the the sprinkler deflector # sprinkler wrench flats, Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers - ' Sprinkler 101d February 26, 2014 NIKING. STANDARD RESPONSE TECHNICAL DATA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 1 (UL) Temperature KEY - Standard Response Standard Orifice Dry Pendent Sprinklers 1i Finish Maximum 175 PSh(12 bar)WWP MX 4-Escutcheon(if applicable) Sprinkler Nominal Order Length Listings and Approvals° Thread Size K-Factor2 Increment (Refer also to Design Criteria below.) Base SIN Style 9 Part No.' NPT BSP U.S. metric' Inches mm cULus' NYC' VdS LPCB (E' co 07740U VK154 Adjustable 1" - 5.6 - 1/2" 12.7 Al,A6 Al - - - - 07854U Standard - 25 mm - 80.6 1/2" 12.7 Al,AS - - - - - 09341 VK155 - 25 mm - 80.6 1/2" 12.7 - - - A2 A2 A2 06530U VK158 Adjustable 1" - 5.6 - 1/4" 6.35 B3, B7 B3 - - - - 07853U Recessed - 25 mm - 80.6 1/4" 6.35 B3, B7 -- - - - - 09342 VK159 - 25 mm - 80.6 1/4" 6.35 - - - B3 B3 B3 07852U VK150 Plain 1" - 5.6 - 1/2" 12.7 A4,A8 A5 - - - - ■07855U Barrel - 25 mm - 80.6 1/2" 12.7 A4,A8 -- - - - - 09343 VK151 _ - 25 mm - 80.6 1/2" 12.7 - -- - A5 AS A5 Approved Finishes and "A" Dimensions 1 - Chrome or White Polyester' sprinkler with a Chrome or White Polyester Sleeve and Escutcheon with "A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) Approved Temperature Ratings 2-Chrome with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) A- 155 °F (68 °C), 175 °F (79°C) 200 °F (93 °C), 3-Chrome or White Polyesters with"A"dimensions 3-1/4"to 47-1/2" (82.5 to 1,207 mm) 4-Chrome, White Polyester'', or Brass with"A"dimensions 3"to 47"(76.2 to 1,194 mm) and 286°F (141 °C) 5-Chrome or Brass with"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) B-155°F(68°C), 175°F(79°C), and 200°F(93°C) 6-ENT'sprinkler with an ENT°Sleeve and Escutcheon with "A"dimensions 1-1/2"to 45-1/2" (38.1 mm to 1,156 mm) 7-ENT°with"A"dimensions 3-1/4"to 47-1/2"(82.5 to 1,207 mm) 8-ENT°with"A"dimensions 3"to 47"(76.2 to 1.194 mm) Footnotes ' Part number shown is the base part number. For complete part number,refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A"Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings,MEA 89-92-E,Vol. 37. ' (E Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. e p MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003. °cULus Listed as corrosion resistant. DESIGN CRITERIA- UL (Also refer-to Approval Chart 1 above.) NOTE:When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees. When selecting other CPVC fittings, contact Viking Technical Services. cLJLus Listino Reauirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray pendent sprinklers. • Designed for use in Light, Ordinary. and Extra Hazard occupancies. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • • Locate no less than 4" (102 mm)from walls. • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured per- pendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. ' February 26, 2014 Sprinkler 101e • NHKING® STANDARD RESPONSE TECHNICAL DATA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com For 'A' Dimension: 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2' (12.7 mm) between 1-1/2' and 45-1/2' (38.1 mm and 1,156 mm). NOTE: The deflector will be located approximately 3-7/16' (87.3 rim) below the ceiling. with 1' (25.4 mm) upward and 1' (25.4 rim) downward adjustment. Deflector at minimum distance below ceiling. NOTE: To locate the deflector *M CtRR at the minimum distance below the ceiling, with no upward adjustment available, 2-7/16' 1 order the dry pendent (61.9 mm) sprinkler 1' (25.4 mm) Minimum ceiling opening Minimum shorter than the A dimension. A / diameter: 1-3/4' (44.5 mm). Maximum ceiling hole diameter: 2-1/4' (57 rim). I=I 13/16' NOTE: To locate the deflector Finished — (20.6 mm) at the maximum distance Ceiling 4 7/16' below the ceiling, with no 1-1/2' III Sleeve finish (112.7 mm) downward adjustment available, (38.1 mm) a matches _ Maximum order the dry pendent diameter escutcheon 'I'. I sprinkler 1' (25.4 rim) 3-1/16' a' ` longer than the A dimension. (77,8 mm) Deflector at maximum distance below ceiling. Figure 3: Adjustable Standard Dry Pendent Sprinkler I ITI _ 110 1 r. For 'A" Dimension r. f Mi II I 1. Determine the distance i mmEmmm from the face of the A tee to finished ceiling. UMMTM 1-- 2. Round to the nearest Minimum ceiling 1/4' (6.35 mm) between Outside A opening size: e For °A' Dimension 2 1/8' (54 mm) 3-1/4' (82.5 mm) and diameter: 47-1/2" (1,219 mm). 1-5/16° 1. Determine distance diameter. (33.4 rim) k from face of' the Maximum ceiling NOTE: The sprinkler will be (same as 1' tee to the base opening size: recessed approximately (25 rim) of the sprinkler. 2-1/2' (63.5 m Schedule 2. Round up to next 5/16' (7.9 mm) above the 40 pipe). higher 1/2' (12.7 mm) diameter. i finished ceiling with 5/8' pp increment between Adjustment: , T (15.8 rim) vertical adjust- 3' (76.2 mm) and 47'-5/16' t- LL Vi meat available. (1,194 mm), ' (7.9 rim) ■I Imp I_,..'-:�I Minimum: C::±-- ``i'� Finished ceiling I i 1-5/8' 1' (25.4 mm) L'._... �i'l(48,3 mm) • Maximum: 3-1/16' _ \ , 1-5/8' (42.1 mm) (77.9 mm) Figure 4: Adjustable Recessed Dry Pendent Sprinkler Figure 5: Plain Barrel Dry Pendent Sprinkler ' Sprinkler 101f February 26, 2014 STANDARD RESPONSE TECHNICAL DATA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 2 (FM) Temperature KEY Standard Response Standard Orifice Dry Pendent Sprinklers l+— Finish AIXf-Escutcheon(if applicable) Maximum 175 PSI (12 bar)WAR Sprinkler Thread Size Nominal K-Factor2 Order Length Increment FM Approvals' Base Part No.' SIN Style NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) 07740U Adjustable 1" — 5.6 — 1/2" 12.7 Al VK154 Standard 07854U — 25 mm — 80.6 1/2" 12.7 Al 06530U Adjustable 1" — 5.6 — 1/4" 6.35 B2 VK158 Recessed 07853U — 25 mm — 80.6 1/4" 6.35 B2 07852U Plain 1" — 5.6 — 1/2" 12.7 A3 VK150 Barrel 07855U — 25 mm — 80.6 1/2" 12.7 A3 — Approved Temperature Ratings Approved Finishes and "A" Dimensions A-155°F(68°C), 175°F(79°C),200°F(93°C), and 1 -Brass, Chrome,White Polyester, or ENT5 sprinkler with a Brass, Chrome, White Polyester, or 286°F (141 °C) ENT''Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2" (38.1 to 1,156 mm) 2-Brass,Chrome,White Polyester,or ENT5 with"A"dimensions 3-1/4"to 47-1/2"(82.5 to 1,207 mm) B-155°F(68°C), 175°F(79°C), and 200°F(93°C) 3-Brass, Chrome,White Polyester, or ENT' with"A"dimensions 3"to 47"(76.2 to 1,194 mm) Footnotes - 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. ' K-Factor applies for standard lengths("A"Dimensions indicated above). _ ' Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. s FM Approved as corrosion resistant. DESIGN CRITERIA- FM (Also refer to Approval Chart 2 above.) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Reauirements: Standard Dry Pendent Sprinklers in the Approval Chart above are FM Approved as standard response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and . standards, whenever applicable. _ j . • February 26, 2014 Sprinkler 101g NIKING® STANDARD RESPONSE TECHNICAL DATA DRY PENDENT STANDARD ORIFICE SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Ambient Exposed Barrel Install 1 inch NPT threaded Up to 2' (50.8 mm) Ambient Temperature end of dry pendent sprink- adjustment available. Temperature 40'F/4•C150'F/10'C160'F/16'C ler into the 1 inch NPT of Protected outlet of a malleable iron BThirEE NEEEEEE Note: Areal, et the Exposed Minimum Barrel Discharge End Length,' Face of Tee n tee fitting per ANSI B 16,3 I- To locate the of the sprinkler to Top of Ceiling V (Class 150) or cast iron deflector at the In.(mm) In.On) In. (rim) threaded tee fitting per minimum distance 40T (4•C) 0 0 0 ; ANSI 16,4 (Class 125) only. 2-7/16' below the ceiling, (61.9 mm) with no upward 30'F (-1'C) 0 0 0 Minimum ceiling opening diameter: VP Minimum adjustment avail- 20'F (-7'C) 4 (100) 0 0 --- able, order the 10'F (-12'C) 8 (203) 1 (25.4) 0 _(Exposed 1-3/4' (44.5 rim) dry pendent sprink- 0'F (-18'C) 12 (305) 3 (76) 0 Barrel) / Maximum ceiling opening diameter: Deflector at ler 1' (25.4 mm) -10'F ( 23•C> 14 (356) 4 (102) 1 (25.4) 2-1/4' (57 mm), minimum distance shorter than the Seal the clearance below ceiling 'A' dimension. -20T (-29'C)l4 (356) 6 (152) 3 (76) / space around the g -30'F (-34'C)16 (406)8 (203)4 (102) sprinkler to avoid leak- -40'F (-40'C)18 (457)8 (203) 4 (102) age of air into the '�-"�� +++++ Note 50•F C-46'C)20 (SOB)l0 (254)6 (152) _ protected area and I�I To locate the -60'F (-51•C)20 (508)10 (254)6 (152) / �; '�r 13/16' consequent formation deflector at the JI i r maximum the(20.6 mm) of condensate around below the telling, Ceiling the frame, which could MINIM with no downward Inhibit operation or ad justment avail- cause premature opera- 4-7/16' able, order the . . \1 1/2' (38.1 mm) tion. Refer to Figure (112.7 mm) dry pendent sprink- 11' Sleeve 7 below. Maximum ler 1' (25.4 mm) diameter longer than the .1 finish If humidity and temp- 'A' dimension. matches erature differential II' 3-1/16' escutcheon causes condensation (Protected Area) on the exposed dry . (77.8 mm) sprinkler, consider Deflector at wrapping the exposed maximum distance barrel with Insulation, below ceiling foam insulating tape, or equivalent. wThe protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. waThe minimum required barrel length is not the same as the 'A' dimension. Refer to Figures 3-5 for the 'A' dimension. NOTE; Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is shown) MIN Il■ ll Seal (or equivalent method) �� Seal RIR ■ .IIIIIII Clearance Insulated Opening '11'• Ceiling 1 Ill , Dry Sprinkler Seal on the Dry Sprinkler Seal Within the Ceiling Exterior of the Ceiling • Figure 7: Dry Sprinkler Seal(Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_071591 Replaces page 101a-g, dated July 17, 2013. (Removed Seal Part Number.) • ' December 12, 2013 Sprinkler 14e MICROMATIC® AND TECHNICAL DATA MICROMATICHP® STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION Viking Micromatic@ and MicromaticHP"'Standard Response Horizontal Sidewall - Sprinklers are small thermosensitive glass bulb spray sprinklers available with various finishes and temperature ratings to meet design requirements. The r I Nickel PTFE ENT coatin s can [1111111 lljl special Polyester, PTFE, and Elect o ess ( ) g �, /.I be used in decorative applications where colors are desired. In addition, • these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion Sprinkler Base Part No. 09849 resistant.) Viking standard response sprinklers may be ordered and/or used as open sprin- klers (glass bulb and pip cap assembly removed) on deluge systems. Refer to - �� Ordering Instructions on page 14f. --•.��!'��1 I I!�; I ICI - ` 2. LISTINGS AND APPROVALS II i ut o5 cULus Listed: Category VNIV FM FM Approved: Classes 2012 and 2015 LPC Approved: Ref. No. 096e/06 Sprinkler Base Part No. 10224 PCB CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD- C E 2001 and 0832-CPD-2003 • Refer to Approval Chart 1 and Design Criteria on page 14h for cULus Listing requirements that must be followed. Refer to Approval Chart 2 and Design Criteria on page 14j for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1996. Minimum Operating Pressure: 7 psi (0.5 bar)' Viking Technical Data may be found on Maximum Working Pressure: Sprinklers VK116 and VK015 are rated for The Viking Corporation's Web site at use with water working pressures ranging from the minimum 7 psi http://www.vikinggroupinc.com. (0.5 bar) up to 250 psi (17 bar)for high-pressure systems. High-pres- The Web site may include a more recent sure (HP) sprinklers can be identified by locating "250" stamped on edition of this Technical Data Page. the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to-65 °F (-55°C) Overall Length: Refer to the Approval Charts "cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinkler 10224. Brass UNS-C84400 for all other sprinklers. Deflector: Copper UNS-C19500 Bushing (for high pressure sprinkler 09997): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 • Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment (for sprinkler 09997): Brass UNS-C36000 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Form No F 123096 Replaces page 14e-k, dated September 30, 2013. — (Added E-3 Escutcheon.) Sprinkler 14f December 12. 2013 NEK6ING® MICROMATIC'''AND TECHNICAL DATA MICROMATICHP'' STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap-ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Standard Response Horizontal Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, and Black PTFE = N, Wax Coated = C, Wax Over Polyester= V-/W, and ENT= JN Temperature Suffix: 135 °F (68 °C) =A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 212 °F (100 °C) = M, 286 °F (141 °C) = G, 360 °F (182 °C) = H, OPEN = Z (PTFE only). For example, sprinkler VK104 with a 1/2" thread, Brass finish and a 155 °F (68 °C)temperature rating = Part No. 10224AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for recessed sprinklers with protective shields: Part No. 13655W/B** (available since 2003) C. Wrench for wax coated sprinklers: Part No. 13577W/B** (available since 2006) "A'A" ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. . 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. Wrench Protective 7. AVAILABILITY Flat Viking Standard Response Horizontal Sidewall Sprinklers are available .QO .� Sprinkler Shield through a network of domestic and international distributors. See The � fi0 - Ir I Viking Corporation web site for the closest distributor or contact The 1 ' Mi it IIIIITiII) Viking Corporation. �' �— III�IIIIIINI 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. 10096 Figure 1: Standard Sprinkler Wrench 10896W/B • . - December 12, 2013 Sprinkler 14g MICROMATIC® AND NIKING. TECHNICAL DATA MICROMATICHP® STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 135 °F (57 °C) 100 °F (38 'C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Extra High 360 °F (182 °C) 300 °F (149 °C) Mauve Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE in all temperature ratings. ENT in all temperature ratings except 135°F (57°C). Wax-Coated Brass and Wax over Polyester for sprinklers with the following temperature ratings: 135 °F (57 °C) Off-White Wax 155 °F (68 °C) Lt. Brown Wax 175°F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 286 °F (141 °C) Dk. Brown Wax' Footnotes The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13. Other limits may apply,depending on fire loading, sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. -The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart.These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester,ENT,and PTFE coatings.For PTFE coated open sprinklers only,the waterway is coated. For all ENT coated sprinklers,the waterway is coated. Wax melting point is 170 °F(76°C)for 286°F(141 °C)temperature rated sprinklers. Sprinkler Wrench Part No. 13655W/B* for Recessed Horizontal Sidewall Sprinklers Protective Fit the wrench over the sprinkler Sprinkler and protective shield as shown. Shield I —... -4—* r4 1' 1 i..___. . / 4- " , I 11 11 I , ,...._II ___ ,, 1111 , \\,,,,-_-_-_-_, I' -- U II *Note: A 1/2' ratchet is required (not available from Viking), Figure 2: Wrench 13655W/B for Recessed Horizontal Sidewall Sprinklers Sprinkler 14h December 12, 2013 MICROMATIC AND TECHNICAL DATA MICROMATICHP® STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 1 (UL) =-Temperature KEY Micromatic°and MicromaticHP°Standard•Res onse Horizontal Sidewall Sprinklers •� Flnisn P,_., . ., p A1X�-Escutcheon ofappllcable) Maximum 175 PSI (12 Bar)WWP (See Footnotes Below for Allowable Deflector Distance Below the Ceiling.) Thread Size Nominal K-Factor Overall Length Listings and Approvals' Base Part Maximum 9 Number' SIN Pressure (Refer also to Design Criteria on pg 141.) NPT BSP U.S. metric' Inches mm cULus" I NYC6 LPCB C E'° (Q" Standard Orifice 10224 VK104 175 psi 1/2" 15 mm 5.6 80.6 2-7/16 62.4 B3W, B1W, B3V, B1V, 10171 VK104 175 psi — 15 mm — 80.6 2-7/16 62.4 A1X A1X A2Y D2Y D2Y Small Orifice 09126 VK016 175 psi — 10 mm 4.2 57 2-7/16 62.4 cULus NYC LPCB E 4.+1 Maximum 250 PSI(17 Bar)WWP Standard Orifice,for Installation 4"to 12" (102 mm to 305 mm) Below the Ceiling. cULus",6 NYC LPCB C E 0 09849 VK116 250 psi 1/2" 15 mm 5.6 80.6 2-11/16 67.6 A1X, B1W, ESZ, D5Y See Footnote 7. — — -- Maximum 250 PSI(17 Bar)WWP Small Orifice6,for Installation 4"to 6" (102 mm to 152 mm)Below the Ceiling. 0999712 VK015 250 psi 1/2" 15 mm 2.8 40.3 2-3/4 69 cULus" NYC LPCB E • Al X, B1W See Footnote 7. — — -- Approved Escutcheons Approved Temperature Ratings Approved Finishes V-Installed with standard surface-mounted escutcheons or the 1 - Brass, Chrome, White Polyester"", Black Viking Microfaste Model F-1 Adjustable Escutcheon, or re- A- 135 °F (57 °C), 155 °F (68 °C), 175 °F(79 ,,, „ cessed with the Viking Micromatic"' Model E-1, E-2, or E-3 Polyester ,and Black PTFE °C),200°F(93°C), 286°F(141 °C),and 360 Recessed Escutcheon 2 - Brass, Chrome, White Polyester, and Black °F(182°C) W - Installed with standard surface-mounted escutcheons or Polyester B-135°F(57°C),155°F(68°C),175°F(79°C), the Viking Microfaste Model F-1 Adjustable Escutcheon, or 3-Wax-Coated Brass and Wax Over Polyester(cor- and 200°F(93°C) rosion resistant) recessed with the Viking Micromatic'Model E-1,E-2, E-3,or C-286°F(141 °C) Model G-1 Recessed Escutcheon D-155°F(68°C), 175°F(79°C),200°F(93°C), 4-High Temperature 200°F(93°C)Wax Coating(cor- X- Installed with standard surface-mounted escutcheons or the rosion resistant); maximum ambient temperature 286°F(141°C),and 360°F(182°C) allowed at ceiling=150°F(65°C) Viking Microfastr Model F-1 Adjustable Escutcheon E-155°F(68°C),175°F(79°C),and 5-ENT" Y-Installed with standard surface-mounted escutcheons only 200°F(93°C) Z-Standard surface-mounted escutcheons or recessed with the Viking Micromatic Model E-1 Recessed Escutcheon. Footnotes 'Base part number shown. For complete part number,refer to Viking's current price schedule. 2 Mefic K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing.Other approvals may be in process. 'Listed by Underwriters Laboratories Inc.for use in the U.S and Canada. cULus Listings limited to Light Hazard Occupancies where allowed by the installation standards being applied,with the deflector 4"to 12`(102 mm to 305 mm)below the ceiling. Approved by the New York City Board of Standards and Appeals under Calendar Number 219-76-SA. Meets New York City requirements,effective July 1,2008. 5cULus Listed for Light Hazard Occupancies where allowed by the installation standards being applied,and Ordinary Hazard Group I and II Occupancies. 'cULus Listings limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet systems. "CE Certified, Standard EN 12259-1,EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. • " p MED Certified,Standard EN 12259-1,EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. • '=The sprinkler orifice is bushed. "cULus Listed as corrosion-resistant. "Other colors are available on request with the same Listings and Approvals as the standard colors. December 12, 2013 Sprinkler 14i NIKING® MICROMATIC®AND • TECHNICAL DATA MICROMATICHP® STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1 on page 14h.) cULus Listing Reauirements: Standard Horizontal Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. • Designed for use in occupancy hazard classifications as indicated in the approval chart, below smooth, flat ceilings only. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m). • Align the top of the deflector parallel with the ceiling. • Locate no less than 4"(102 mm)from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Carefully press the wrench onto the sprinkler wrench flats. Wax Coated . NSW Sprinkler I! L I r 101r i �IiI Y { I 711 l ► 1 NEW 1/2' ratchet is required q ed • (not available from Viking). Sprinkler Wrench 13577W/B*w for installing wax coated sprinklers • Figure 3: Wrench 13577W/B for Wax Coated Sprinklers • . - Sprinkler 14j December 12, 2013 NnuNG. MICROMATIC® AND TECHNICAL DATA MICROMATICHP® STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 2 (FM) Temperature KEY Micromatic°Standard Response Horizontal Sidewall Sprinklers . Finish A iX4—Escutcheon(if applicable) Maximum 175 PSI(12 Bar)WWP Base Part SIN Maximum Thread Size Nominal K-Factor Overall Length FM Approvals' Number' Pressure NPT BSP U.S. metric Inches mm (Refer also to Design Criteria below.) 10224 VK104 175 psi 1/2" 15 mm 5.6 80.6 2-7/16 62.4 A1X, B1W 10171 VK104 175 psi — 15 mm — 80.6 2-7/16 62.4 Approved Escutcheons Approved Temperature Ratings W- Installed with standard surface-mounted escutcheons or the A-135°F 57°C), 155 °F(68°C), 175°F 79°C , Approved Viking Microfast° Model F-1 Adjustable Escutcheon, or re- 200 ( ( ) pproved diCishes cessed with the Viking Micromatic° Model E-1, E-2, E-3, or 200 °F(93°C), and 286°F(141 °C), 1 -Brass and Chrome g B-135°F(57°C), 155°F(68°C), 175°F(79°C) Model G-1 Recessed Escutcheon and 200°F(93°C) X - Installed with standard surface-mounted escutcheons or the Viking Microfast6 Model F-1 Adjustable Escutcheon Footnotes 'Base part number shown. For complete part number, refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Other approvals may be in process. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Sprinkler VK104 is FM Approved as a standard response Non-Storage sidewall sprinkler as indicated in the FM Approval Guide. For specific applica- tion and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including 2-0)and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply require- ments, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations,and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. • • Sprinkler 14k December 12, 2013 • a NUKING® MICROMATIC® AND TECHNICAL DATA MICROMATICHP® STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Wall Opening Size: 2-5/16' (58.7 mm) minimum 2-1/2' (63.5 mm) maximum 2"(50,8 M Z 7/l6' _ 2-11/16' (61.9 m ) rs) (68.3 mm) �- I Minimum T-_ �I I'Il C31.8 mm) '_��`�i C541 m8) J I Ii!,� ; — M (15 mm) �' NPT NSW Sprinkler pl 2-1/2' 09849 (VK116) - (63.5 mm) Installed with a standard Maximum 1/8' (3.1 rim) surface- mounted escutcheon Installed with a Microfast Model F-1 Adjustable Escutcheon Figure 4: Sidewall Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Wall Opening Size with the A 1-5/8' Model E-1 or E-2 Escutcheon: 2-5/16' (58.7 mm) minimum 1-3/4' - • I(41.3 mm) 2-1/2' (63.5 mm) maximum , (44.5 mm) Minimum t - - Minimum — Nil, m,„_. li '��`�,' �� 2-1/8' Fillip ,� (54 mm) I Alin/: (54 mm) ' i, I i 1, IIIIUI� 2-1/4' 2-5/8' (57.2 mm) (67 mm) _ Maximum ' Maximum Installed with a Micromatic Installed with a Model E-2 Model E-1 Recessed Escutcheon Thread-on Recessed Escutcheon Figure 5: Sidewall Sprinkler Dimensions with the Model E-1 or E-2 Recessed Escutcheons Wall Opening Size with the Model G-1 Escutcheon 1/8' 2-5/8' (66 mm) minimum (3.2 mm) 3-3/4' (95 mm) maximum Adjustable 1 Adjustable- Outer Cup IIII Adapter Ring _ Nal � \ 'I\I I■ !I' , � (66 m8) (102 mm) /I` , ,/•-�\ NI:A-. ,i, Depth: . • . 1-1/16' , II (27 mm) 1-1/161 Y Maximum Recess: (27 mm) 1/2' (12.7 mm) Figure 6: Sidewall Sprinkler Dimensions with the Model G-1 Recessed Escutcheons am m 441-G E INTENTIONALLY LEFT BLANK Form No. F_123096 Replaces page 14e-k, dated September 30, 2013. (Added E-3 Escutcheon.)