Loading...
Permit p CITY OF TIGARD ENT Permit#:MECHANICAL MEC2015-00154 PERMIT `�'! COMMUNITY DEVELOPM TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 03/30/2015 Parcel: 2S112AA00300 Jurisdiction: Tigard Site address: 14200 SW 72ND AVE Project: Gerber Blades Subdivision: MILLMONT PARK Lot: 49 Project Description: Add 15K ductless mini split to a modular building. Contractor: SPECIALTY HEATING&COOLING INC Owner: ASGARD LLC 7500 SW TECH CENTER DR STE 130 BY GERBER LEGENDARY BLADES TIGARD, OR 97223 14200 SW 72ND AVE PORTLAND, OR 97223 PHONE: 503-620-5643 PHONE: 503-403-1251 FAX: 503-681-0793 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 03/27/2015 $232.50 Class of Work: ALT Type of Const: VB Plan Review 03/27/2015 $58.13 Occupancy Grp: F-1 Occupancy Load: 12%State Surcharge-Mechanical 03/27/2015 $27.90 Stories: Info Process/Archiving-Sm$0.50(up to 03/27/2015 $4.00 11x17) Project Valuation: $5,888.00 Fuel Air Handlers Fuel Types: Units< 10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $322.53 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: 15K mini split Duct Work: system Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-1090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.:'+ • 44. I AIssued By: •: mittee Signature: / id- Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until comp -tion • the pr•'e t. Approved plans are required on the job site at the time of each inspe '• . Mechanical Permit Applicati 4ECEIVED FOR OFFICE USE ONLY Received City of Tigard Date/ y , Pennit No./ ( 0/5 _��2S y _ • 13125 SW Hall Blvd.,Tigard,OR 97223 MAR 2 2015 Plan vi Phone: 503.718.2439 Fax: 503.598.1960 Date/By rrte�!i Other Perm'',,'Q /pOD e-� �C7 �� Ste/�1/�" !/ _J TIGARD Inspection Line: 503.639.4175 CITY OF TIGARD Date Rea By: Juru ® See Page 2 for Internet: www.tigard-or.gov BUILDING DIVISION . Notified/Method: 3 6.77 77( Supplemental Information ' .' it(-AM R AL F oit Mechanical permit lees*are based on the value of the work ❑New construction X Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overh d.and profit. Value:$ 5, 8 g A i EQUIPMENT/SYS ❑ 1-and 2-family dwelling x Commercial/industrial ❑Accessory building For special information use checklist. ❑Multi-family ❑Master builder ❑Other: Description I Qty. I Ea. I Total ICON Heating/cooling: y2Q0 s Air conditioning 46.75 � Job site address: 7 71„oL AUK Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:'r'i��� t o k 9 7123 £LA6Ey Furnace 100,000+BTU(ducts/vents) 54.91 Heat r 2 .32 Suite/bldg./apt.no.: Project name: fOdv IA( b !;/ri- n) Duct work 23.32 Cross street/directions to job site: 71 not_ ol- 80(1,1-c.,... Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. _ 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: __ Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORKIIIIF Gas fireplace/insert 33.39 Flue vent for water heater or gas ADD 0._ /Sk &;k.et 0i-'cTle$$ Al:its, S9ei 7-e, c,.. fireplace 23.32 Log lighter(gas) I 1 23.32 I rnoci,lo,r by;fd i()) i(i S%)C Gerber 13ki45 Pobin5 Wood/pellet stove 33.39 C M M 1VIaG k;/1e. Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 _ Other: 23.32 02 PROPERTY OWNER Environmental exhaust and ventilation: Name: i' S)Car's (Yana& =N�• Range hood/other kitchen _ equipment 33.39 _ Address: Z5 37 0 Qn;e t S f . Clothes dryer exhaust 33.39 City/State/ZIP:so.a.�Son = S 3 7/Q Single duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 Other 1 23.32 Fuel piping: Business name: $14.15 for first four;$4.03 for each additional Contact name: /9—A446 igE,,9 Fuace,etc. Address: /N Furnace,Gas heat pump Wall/suspended/unit heater City/State/ZIP: Water heater Phone`( 3 ) 6 v� —Se y3 Fax.. Fireplace Range E-mail: Barbecue -. ,CONTRACTOR Clothes dryer(gas) Other: Business name: 5 f ec;a I Ty itea..i n COO(in o 7 Address:'7SOc7 Su-, mec11 CenTer U! .-J.w/30 Subtotal City/State/ZIP: i p�� O �Z Minimum permit fee(n t fee) J ` Plan review(25%of permit fee) Phone:(co N )6 Z0 —s 6 Lf 3 Fax:( ) State surcharge(12%of permit fee) CCB lic.:66 sj 7,,1 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within ISO ,Glt� days after it has been accepted as complete. Authorized signature: /1 • Fee methodology set by Tri-County Building Industry Service Board Print name: 6 f eg 7^ee/c.. Date:3-?...4-/c- , I:\Building\Permits\MEC_PcnnitApp_040I 13.doc 440-4617T t I I/02/COM/WEB) RECEIVED 3 �yv. P •� Y. LEADING TECHNICAL PERFORMANCE MAR 24 2015 CITY OF TIGARD J Quaternity Premium Efficiency System Performance :UILDING DIVISION Indoor Model FTXGO9HVJU FTXG12HVJU FTXG15HVJU Outdoor Model RXGO9HVJU RXG12HVJU RXG15HVJU Cooling Capacity(Rated) Btu/h 9,000 12,000 15,000 Cooling Capacity(Min—Max) Btu/h 5,300-12,300 5,300-15,700 5,300-18,000 Heating Capacity(Rated) Btu/h 12,000 16,000 18,000 Heating Capacity(Min—Max) Btu/h 4,400-18,000 4.400-19,100 4,400-21,200 SEER 26.1 24.2 21.0 EER 15.8 14.0 12.9 HSPF 11.0 10.6 10.0 Power Supply Single phase 60Hz 208/230V Minimum Circuit Amps A 14.5 14.5 14.5 Maximum Overcurrent Protection A 15.0 15.0 15.0 Power Consumption-Cooling W 250-900 260-1,300 260-1,930 Power Consumption-Heating W 220-1,900 220-2,100 230-2,120 Operating Current-Cooling A 3.1 4.3 5.64 Operatin. Current-Heatin• A 4.04 5.64 6.36 Indoor Units-FTXG_HVJU Wall Mounted Units Model Name FTXGO9HVJU FTXG12HVJU FTXG15HVJU Moisture Removal gal/h 3.3 4.1 4.8 Airflow-Wet(H/M/L) CFM 420/325/230 459/346/240 487/371/258 _ Airflow-Dry(H/M/L) CFM 438/346/258 470/367/272 494/392/293 Sound Pressure-Cooling(H/M/L) dB(A) 42/33/26 43/35/27 45/37/29 Sound Pressure—Heatin H/M/L dB(A) 42/35/28 - 43/36/29 44/38/31 Piping Connections Liquid(O.D.) in. 01/4 0 1/4 01/4 Gas(O.D.) in. 0 3/8 0 3/8 01/2 ' Condensate Drain in. 0 11/16 0 11/16 0 11/16 Dimensions(H x W x D in. 12 x 35-1/32 x 8-7/32 Outdoor Units-RXG_HVJU Heat Pump Model Name RXGO9HVJU RXG12HVJU _ RXG15HVJU Sound Pressure Level-Cooling/Heating dB(A) 46/46 49/48 50/50 Operating Range-Cooling °F DB 14-109 14-109 14-109 Operating Range-Heating °F DB -4-75 -4-75 _ -4-75 Max.Piping Length ft. 32 32 32 Max.Piping Height ft. 26 26 26 Dimensions(H x W x D) in. 22-3/8 x 31-9/32 x 11-7/32 Net Weight lbs. 99 99 99 Options Part Number Indoor Unit Condensate Pump • 1 DACA-CP1-1 Outdoor Unit . Mounting Bracket DACA-WB-3 Air Adjustment GnlICITY OP TIGARD KPW937A4 REVIEWED FOR CODE COMPLIANCE Approved: [t„..} OTC: [ Pc'rniit #: tA. Z4%tS-Of)( A, :4.ress: V-z�j© caw`Z1 . S Ate 4 I3_,: `0 ilk Date: 3601(47— OFFICE COPY sr*5, 4t 1 s t .,:17,,,,, ,7117,:.,:.r j e ,y_T.,.l:;,y; : ' au., -t" ; `''t1 �T;, {A _"'jG r ti`a .,,- ' ' �r 9 rs,.i: RECEIVED SITE PLAN Ge f}�f. O/ S MAR 2 4 2015 . CITY OF TIGARD BUILDING DIVISION PT 1 madvkkc Go; i"5 P L Inside PL 007-boor vn jT On [ way •►,ec. fiber inch, aca•■ ilitct • FL STREET NOTE — Please show the following on the site plan: • Location of Indoor Unit and Outdoor Unit :• Indicate how the flue will be run (thru the roof— out the sidewall — etc) • Indicate with dotted line how the lineset will be run and approx. distance :• Indicate how the condensate will be run f.� S `'I 7500 SW Tech Center Drive pecialty Suite #130 Tigard, OR. 97223 HEATING &COOLING INC. (503)620-5643 Fax: (503)681-0793 www.specialitvheatina.com We're not iuuilortnblr lentil you ii Specifications 60Hz 230V EDUSO4-906_b . 3. Specifications 60Hz 230V Indoor Units FTXGO9HVJU FTXG12HVJU Models Outdoor Units RXGO9HVJU RXGI2HVJU Capacity Btu/h 9,000(5,300-12,300) 12,000(4,400-18,000) 12,000(5,300-15,700) 16,000(4,400-19,100) Rated(Min.-Max.) Moisture Removal Pt/h 3.3 - 4.1 - Running Current(Rated) A 3.10 4.04 4.30 5.64 Power Consumption Rated(Min.-Max.) W 570(250-900) 780(220-1,900) 860(260-1,300) 1,160(220-2,100) Power Factor % 80.0 84.0 87.0 89.5 EER(Rated) Btu/11-W 15.8 - 14.0 - COP(Rated) W/W - 4.51 - 4.04 Energy SEER/HSPF 26.1 11.0 24.2 10.6 Efficiency Liquid inch(mm) 0 1/4"(6.4 mmm) 0 1/4"(6.4 mmm) Piping Gas inch(mm) 0 3/8"(9.5 mm) 0 3/8"(9.5 mm) Connections inch(mm) Drain 011/16"(17.5 mm) 0 11/16"(17.5 mm) Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes Max.Interunit Piping Length feet(m) 32 ft(10 m) 32 ft(10 m) Max.Interunit Height Difference feet(m) 26 ft(8 m) 26 ft(8 m) Chargeless feet(m) - - Amount of Additional Charge of oz/ft - Refrigerant - !;i'a f'fY N. ! i . : i.,7 .-.!. _ i. -r.i_ `,. .I. - a ih414,. x Front Panel Color White White H 420(11.9) 438(12.4) 459(13.0) 470(13.3) Airflow Rate cfm(m3/min) M 325(9.2) 346(9.8) 346(9.8) 367(10.4) L 230(6.5) I 258(7.3) 240(6.8) 272(7.7) Type Cross Flow Fan Cross Flow Fan Fan Motor Output I W 57 57 Speed j Steps 5 Steps,Quiet and Auto 5 Steps,Quiet and Auto Air Direction Control Right,Left,Horizontal and Downward Right,Left,Horizontal and Downward Air Filter Removable/Washable/Mildew Proof Removable/Washable/Mildew Proof Running Current(Rated) A 0.12 0.14 0.14 0.15 Power Consumption(Rated) W 24 26 29 I 31 Power Factor _ % 87 80.7 90.1 89.9 Temperature Control Microcomputer Control Microcomputer Control . Dimensions(HxWxD) inch(mm) 12 x 35.1/16 x 8-1/4"(305 x 891 x 210 mm) 12 x 35-1/16 x 8-1/4"(305 x 891 x 210 mm) Packaged Dimensions(HxWxD) inch(mm) 11 x 37-5/8 x 14-7/8"(279 x 956 x 378 mm) 11 x 37-5/8 x 14.7/8"(279 x 956 x 378 mm) Weight Lbs(kg) 31 lbs(14 kg) 31 lbs(14 kg) Gross Weight Lbs(kg) 38 lbs(17 kg) 38 lbs(17 kg) Operation Sound H/M/L dBA 42/33/26 42/35/28 43/35/27 43/36/29 Casing Color Ivory White Ivory White Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type Compressor Model 2YC36CXD 2YC36CXD Motor Output I W 1,100 1,100 Refrigerant Type FVC5OK FVC5OK Oil . oz 13.5 13.5 Refrigerant Type R-410A R-410A Charge Lbs 3.1 3.1 Airflow Rate cfm(m3/min) H 1,178(33.4) 1,095(31.0) 1,262(35.7) 1,111(31.5) L - - - - Fan Type Propeller Propeller Motor Output W 60 60 Running Current(Rated) A _ 2.98 _ 3.9 4.16 5.49 Power Consumption(Rated) W 546 754 831 1,129 Power Factor % 79.7 84.1 86.9 89.4 Dimensions(HxWxD) inch(mm) 22-3/8 x 31-5/16 x11-1/4" 22-3/8 x 31-5/16 x11-1/4" (568 x 795 x 286 mm) (568 x 795 x 286 mm) Packaged Dimensions(HxWxD) inch(mm) 25-3/16 x36-7/16 x14-7/8" 25-3/16 x36-7/16 x14-7/8" (568 x 795 x 286 mm (568 x 795 x 286 mm) Weight Lbs(kg) 99 lbs(45 kg) 99 lbs(45 kg) Gross Weight Lbs(kg) 104 lbs(32 kg) 104 lbs(32 kg) Operation H/L dBA 46/- I 46/- 49/- I 48/- Sound Drawing No. 3D062857 3D062858 Note: - Conversion Formulae •The data are based on the conditions shown in the table below. " Cooling Heating Piping Length to h=kWx 414 Btu/h=kWx3414 Indoor;80°FDB/67°FWB Indoor;70°FDB/60°FWB 25f1(7.5 m) cfm=m'/minx35.3 Outdoor;95°FDB/75°FWB Outdoor;47°FDB/43°FWB - 4 Room Air Conditioners H-Series EDUSO4-906_b Specifications 60Hz 230V 60Hz 230V Indoor Units FTXGI5HVJU • Model Outdoor Units RXGI5HVJU Cooling Heating Capacity Btu/h 15,000(5,300-18,000) 18,000(4,400-21,200) Rated(Min.-Max.) Moisture Removal Pt/h 4.B - Running Current(Rated) _ A 5.64 6.36 Power Consumption Rated(Min.-Max.) W 1,160(260-1,930) 1,320(230-2,120) Power Factor % 89.0 99.0 EER(Rated) Btu/h•W 12.9 - COP(Rated) _ WAN - 3.99 Energy SEER/HSPF 21.0 10.0 Efficiency Liquid inch(mm) 0 1/4"(6.4 mmm) Piping Connections Gas inch(mm) 0 3/8"(9.5 mm) Drain inch(mm) 0 11/16"(17.5 mm) Heat Insulation Both Liquid and Gas Pipes Max.Interunit Piping Length feet(m) 32'(10 m) Max.Interunit Height Difference feet(m) 26'(8 m) Chargeless feet(m) - Amount of Additional Charge of Refrigerant oz/ft - ou160unit , FTXG75HVJU Front Panel Color White H 487(13.8) 494(14.0) Airflow Rate cfm(m3/min) M 371(10.5) 392(11.1) L 258(7.3) 293(8.3) Type Cross Flow Fan Fan Motor Output W 57 Speed Steps 5 Steps,Quiet,Auto Air Direction Control Right,Left,Horizontal,Downward Air Filter Removable/Washable/Mildew Proof Running Current(Rated) A 0.15 0.16 Power Consumption(Rated) W 33 35 Power Factor °r, 95.7 95.1 • Temperature Control Microcomputer Control Dimensions(HxWxD) inch(mm) 12 x 35-1/16 x 8-1/4"(305 x 891 x 210 mm) Packaged Dimensions(HxWxD) inch(mm) 11 x 37-5/8 x 14-7/8"(279 x 956 x 378 mm) Weight Lbs(kg) 31 lbs(14 kg) ' Gross Weight Lbs(kg) 38 lbs(17 kg) Operation H/MIL dBA 45/37/29 44/38/31 Sound Outdoor Unit RXGISHVJU Casing Color Ivory White Type Hermetically Sealed Swing Type Compressor Model 2YC36CXD Motor Output I W 1,100 Refrigerant Model FVC5OK Oil Charge I oz 13.5 Model R-410A Refrigerant Charge Lbs 3.1 H 1,262(35.7) 1,195(33.8) Airflow Rate cfm(m3/min) L - - Fan Type Propeller Motor Output W 60 Running Current(Rated) A 5.49 6.2 Power Consumption(Rated) W 1,127 1,285 Power Factor % 89.3 90.1 Dimensions(HxWxD) inch(mm) 22-3/8 x 31.5/16 x11-1/4" (568 x 795 x 286 mm) 25-3/16 x36-7/16 x14-7/8" Packaged Dimensions(HxWxD) inch(mm) (568 x 795 x 286 mm) Weight Lbs(kg) 99 Gross Weight Lbs(kg) 104 Operation H/L dBA 50/- 50/- Sound Drawing No 3D062859 Note: • •The data are based on the conditions shown in the table below. Conversion Formulae Cooling Heating Piping Length kcal/h=kWx860 Indoor;80°FDB/67'FWB Indoor;70°FDB/60°FWB Blu/h=kWx3414 Outdoor;95°FDB/75°FWB Outdoor i 47°FDB/43°FWB 25 ft(7.5 m) cfm=m3/minx35-3 Room Air Conditioners H-Series 5 Dimensions EDUS04-906 b 4. Dimensions FTXG09/12/15HVJU THE MARK(-s)SHOWS PIPING DIRECTION REQUIRED SPACE 4(), %fee ,r2 35-1/16(690) [>AIR FLOW(INDOOR) •0•It REAR / WQ ----� (INCLUDING ) i LEFT =--—== RIGHT \MOUNTING PLATE/ Q w+i _�� 10.13'16(275 Imo_ I ��ry!�� 1-15/16(50/MIN. CI 1 1.15/15509.). GEAR CASE UIfT FD(ED SCREWS -- (SPACE FOR (SPACE FOR 7 (INSIDE PANEL) ,r . MAINTENANCE) PERFORMANCE) NAME I NI PLATE (INSIDEBANEL)CREWS iR � 'I �' (INSIDE PANEL) V. I BOTTOM i M)LIICOLOR®R& ATOR UMW TIMER LAMP INDOOR IRITCWCIT SWITCH OPERATING STATE ROOM TEMP. THERMISTOR 1 M._ TERMINAL BLOCK WITH EARTH TERMINAL GAS PIPE 43AT(9.5)CN DRAIN HOSE CONNECTING PART 11� - - LIQUID PIPE 41/4(6.4)CUI LD• 4116(14) SIGNAL RECEIVER O.D.411/15(16) SIGNAL TRANSMITTER BLADE ANGLE 1.7/16(37) B38 9/16 15 2-12(63) 1-1116(269) UP/DOWN(AUTOMATIC) \ m_ 1 COOLING AIR PURIFYING NMI {{�� DRY COOLING HEATING (INDIVIDUAL OPERATION) I I DRY 15: - I WALL HOLE . /� / I �HOLE( )aiM ■ zo (/Q//7®/ 15� ir° `� \ , WALL EM B DDEDPttIG 2516158.5) 7� 42-9/16(651 HOLE APPROX.21.9/16(548) I. • 55° 70' 55' 55 1.7.47)-2 .60 APPROX.23-9/16(598) e�• 4. APPROX.25.13/16 655 Y ! RIGHT/LEFT WIRELESS REMOTE CONTROLLER STANDARD LOCATIONS OF WALL HOLES (AUTOMATIC) (ARC447A3) / 3D061002 RXG09/12/15HVJU 22-5/8(574) 3-3/4)95.5) 0 19-7/8(505) N I* ''DRAIN OUTLET (1.045/6)15.9) 'r� ' 1 4-HOLES FOR ANCHOR BOLTS HOSE FOR CONNECTION I 1 1 I I I (MB OR M10) ll 1 i y I HANDLE BRAND NAME LABEL GAS STOP VALVE OUTDOOR AIR THERMIS70R 9/16)15) 31-516(795) 2-12(63) (43/8(9.5)CuT) It= _ LIQUID STOP VALVE I=--_ 0 -- -_ _= i 11 ` GAS SERVICE II� ���. (Ot/4(6.4)CuT)II-_-_ Oa - II :,.-:: —II j (I NAMEPLATE y,I -4 Ij���= 0 II III I 1�P. - 1. `C� O� 11 III h1J I a L !!!I! 00• II _ III =���i "• 00 II _--_== mil AI I I :. : >,■I I13/16(20) 11/16(17) 11-1/4(285) • 5/8(15.7) .... 12(13) ,— 12-1/4(311 4.5/9(116) WALL HEIGHT ON AIR OUTLET SIDE 'q-' (BASE PITCH) MINIMUM SPACE FOR AIR PASSAGE I =LE55 THAN 47-3/76(12D0) P IN CASE OF REMOVING (6 STOP VALVE COVER Cr Ig .. I. C. .. Si Y .. .. 4y I � � ) I � � I s - 4 1-1516)50) ,h 1-15/16(50) I -f/'1-1576(--' W C. 1 UNIT=INCH(mm) • N 3D062671A 6 Room Air Conditioners H-Series EDUSO4-906_b Wiring Diagrams 5. Wiring Diagrams FTXG09/12/15H VJU AlP-ASP :PRINTED CIRCUIT BOARD FG :FUME GROUND F1U '.FUSE HIP MULTI MONITOR oLr CAUTION 142P H3P PILOT LAMP outdoor NOTE THAT OPERATION WILL SIC :LIMIT SWITCH FOR PANEL i RESTART AUTOMATICALLY IF WC :ME SWITCH FOR STREAMER TURNED OFF AND THEN BACK MI F :FAN MOTOR i A3P 1 ® ON AGAIN. RIT I2T :TIERISIOR RECEIVER)I WIRELESS' I SI-S403,CN1:CONNECTOR I 556 'LL,_,WIRELESS/ NTROLEER 1,1!”‘ SIW :OPERREN SWITCH ' .---- -----.---T SIN :TERMINAL STRIP I ' mmm )• YISY2S :SOLENOID VALVE �� ZIC :FERRITE CORE I LEp3L�D2 MULTI \11 ® :PROTECTIVE GROUND S5T Qfl H2 MONITOR %1M U©©., JUMPER S1W •JA H3P N2P ® [,. 21 0 13 556 HIP JA IYIr�3NMffmmGISE1 IBII 1 Ni; z -. J A2P r ----'---- uuuulou R7T AtP r.T.T.T.T.T.T.T.T.T.Y.T.T.] TRANSMISSION ii-I, ' S48 13 CIRCUIT I n2 Fr xK i!S32 HI :.I ItF 6 521 1 FtLI •1 RI HA (H250V,T3.I5A 1 111 1 .I Mimic I. s Iffi ix 1 S43 S52 S41 S1 S51 ® I1 4 1 5 16PIN ..... 1 4 7 1 7 =zz: C1 5 E3•ZI•>a•7 EZIZ)[Z77 L L 3 � : @Bs e0; 0000 0 lI i � Islt STREAMER PART 0 to 1 .1 j--a-C 1 M1S M2S M3S M1F r A 5 yd . I S2C S403 Lt• ��6RN C ' $401 6 U 11� rr �s+oz - - - - - - - - - - J I ASPS indoor 3D052766C RXG09/12/15HVJU Lt Tom KID WIRING indoor n '�I L�74OS� S45 3 1 or 1 ii0 HL130A —A 20 DB1 IPMI �; liC MRM10 HRI HR2I + +s+ + 4.2 �R IOC"' ..7^� i v w L1{ I XTM Z4C Li ■VI N=2 • HSA1 FU1 II 11® N=3 3.15A FU2 II j 3.15A PCB1 MR4 �o p 1 S20 1 S90 6 1 523 4 7 OL1 OL2 U V W 673•T•FT 7 10 0 I 0 9 01 E T.=., egg tij il I 3 outdoor X1/1f L r r r 1 1 VIE * B,a Y 1 R y. NOTE R1T Or R3T i7 N_3 I.REFER TEl THE NAMEPLATE FOR THE POWER REQUIREMENTS. (OUTDOOR) (DISCHARGE) M1 F U W (CONDENSER) OIL M1C D1111,D132,DB3 :DIODE BRIDGE Flit FU2.FU3 :FUSE J IPM1 :INTELUGENT POWER MODULE I L.,L :LIVE PCB1 :PRIMED CIRCUIT BOARD X11.1 :TERMINAL STRIP LIR :REACTOR OIL :OVERLOAD PROTECTOR YIE :ELECTRONIC EXPANSION VALVE COIL MR4,MRM10 RIT R2T,R3T :THERMISTOR VIR :REVERSING SOLENOIDE VALVE COIL MRM20 :MAGNETIC RELAY SAt :SURGE ARRESTER ZI C.Z2C.Z3C.Z4C :FERRITE CORE MIC :COMPRESSOR MOTOR VI,V2 :VARISTOR Q :PROTECTIVE GROUND T IMF :FAN MOTOR XIA :CONNECTOR 3D061486 Room Air Conditioners H-Series 7 Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 14200 SW 72ND AVE, TIGARD, OR, 97224 Commercial - Mechanical 699 Mechanical final PASS - No C of O MEC2015-00154 Jeff Grove Violation Summary: Inspector Contractor