Loading...
Permit CITY OF TIGARD MASTER PERMIT IN a-. COMMUNITY DEVELOPMENT a i 1 Permit#: MST2015 00008 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Pl Date Issued: 02/24/2015 Parcel: 2S109DB05900 Jurisdiction: TIGARD Site address: 13293 SW HAZELCREST WAY Subdivision: SEQUOIA HEIGHTS Lot: 7 Project: Sequoia Heights, Lot 7 Project Description: New SF. Sewer connection for lot done previously for temporary sales trailer on this lot. 7/7/15: Reprinted permit to include A/C unit. BUILDING Floor Areas Required Setbacks Required Stones: 2 Bedrooms: 4 First: 1074 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 23 Bathrooms: 3 Second: 1318 sf Garage: 701 sf Front: 15 Smoke Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Yes Total: 2392 sf Value: $294,781.60 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain 0 Other Fixtures' 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf. 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener N All Other N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2392 Owner: Contractor: LENNAR NORTHWEST INC LENNAR NORTHWEST INC Required Items and Reports(Conditions) 15060 SW 133RD AVE 11807 NE 99TH STREET SUITE 1170 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97224 VANCOUVER,WA 98682 PHONE- 360-258-7900 PHONE: 360-216-6423 FAX: 360-258-7901 Total Fees: $22,609.39 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. - � Issued By: .f/_ - %1� •ermittee Signature: maniplIr Cal175 by 7:00 a.m,for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13293 SW HAZELCREST WAY, TIGARD, OR, 97224 Residential - Master Permit 399 Plumbing final FAIL MST2015-00008 David Young House locked, provide access for inspections. Recall with access provided. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13293 SW HAZELCREST WAY, TIGARD, OR, 97224 Residential - Master Permit 199 Electrical final FAIL MST2015-00008 David Young Receptical and cover still missing in garage as noted on previous failed inspection. wires not safed off. All else ok. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13293 SW HAZELCREST WAY, TIGARD, OR, 97224 Residential - Master Permit 399 Plumbing final FAIL MST2015-00008 David Young cleanout plug needs approved thread sealant at: 316.1.1l, Secure faucet at right side of garage and seal penetration. Violation Summary: Inspector Contractor Jul. 7. 2015 7:08PM LENNAR N. W. 360-258-7901 No. 0253 P. 2 Mechanical Permit Application FOR OFFICE USE ONLI City of Tigard " � V r ee 7 III‘ • 13125 SW Hall Blvd..Tigard.OR 97223 Phone. 503.718.2439 Fa 503.598.1960 Review Date/By: odor Permit. 1 1G ARll Inspection Line; 503.639.4175 RECEIVE Date Ready/By torts: Fl See Page 2 for Internet www.tigard-or.gov s Notr5ed/Method: rt t�' supplemental Information S N y� e dF:r h l l!ytMYR�u M; ip �' F �s 13:17,4„._.7i.- Foil..Ip NF. T { a�a �-: 7 Ye L. «: � ' ; " Mechanical permit fees'arc based on the value of the work ®New construction ❑Addition/altetat ►at+tiGAIRD performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other rt ' 11 NG DiVlt.iS, �I O..N�.._� r. mechanical materials,equipment labor,overhead,and profit v alue S 11Irt M ; Vtxe 1� d1;tiyy154.`d'l ia7..N19)i `11 li r_ 'l r' s i i F;YY s`)�lii r Ii tif: t ii ,��J e y,a a :y.-�.�a• ® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information wse checklist_ u1 ❑Multi-family 0 Master builder ❑Other: Description I Qty. r Ea- 1 Total �.• t • Heating/cooting• . :. . '1.l" .71.:,tit,g it '" 1!f 4 e41�I I I„�1.0;f4.:.0,(00 •t AAI,'-,FS .;.:.T l ,F; Air conditioning 1 46.75 Job site address:13293 SW Hazclerest Way Furnace 100,000 BTU(ducts/veers) 46.75 City/Stale/DP:Tigard,OR Furnace l00 000+BTU(ducls/vena) 54.91 Beat pump 61.06 Suite/bldgiapt no.: I Project name: Duct work 23.32 Cross street/directions to job site: Ilydronie hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision:Sequoia Heights ILot no.:7 Omer. 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 2332 " € I r ' ^ 1?r 'o"ik( t tom. I'1 0 y d , �r ry t:''1':'''''''''''''''''-1" -`�3 7 i : k Gas fireplace/Insert 3339 ,�, wi.�,'' °`7" "' " ' � "� ' ''`' Flue vent for water heater or gas NSFR fireplace 23.32 Add A/C to permit 0 MST2015-00008 Log lighter(gas) 2332 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 i sr, r r`• 4i 'yF 1 ,1; ;t'erAr`3 6J 7°u ;V t !t ,::; `yRcr:�;•t Other: 23.32 , ; lit a k',r Nria, ,: ",„i,• •k , - ! d, kl,. , '•, ,,-1 •< s Environmental exhaust and ventilation: Name:Lennar NW Inc. Range hood/other kitchen equipment 33.39 Address:11807 NE 996 St,Suite 1170 Clothes dryer exhaust 33.39 City/State/ZIP:Vancouver,WA 98682 Single-duct exhaust(bathrooms. toilet compartments,utility rooms) 23.32 Phone:(360)25`8.-7900 p gyp, Fax:(g3�60))258-7901 Attic/erawlspace fans 23.32 1 ''.'NW,' /.-•'d inn,sue °�,q,,i,,t i!l{S,;' rr � iattlii;t �:'tl . , '.^• Other. 23.32 —,1 is .. . - Fuel piping: Business name:SAME $14.15 for first four;$4.03 for each additional Contact name: Furnace,etc. Address: Gas heat pump ,, Wall/suspended/unit hey ter — City/State/ZIP: Water heater Phone:( ) Fax::( ) Fireplace r Range E-mail:jj } �} j����jj Barbecue I o:4P.u,'r��^df;i,+ ;M„irt,ik l4 ,n .`r'riq a�' i 1`c a5:b➢� rr,i t t 4 j,. ' i t 4fi 41, �.H' i Clothes dryer(gas) Business name:Tri County Temp Control Other Address:13150 S.Clackamas River Dr. Subtotal — City/State./ZIP:Oregon City,OR 97045 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(503)557-2220 Fax:(503)557-0919 State surcharge(12%ofpermit fee) CCB lie.:72623 TOTAL PERMif FEE This permit application expires if a permit is not obtained within 180 days after It has been accepted as complete. Authori2ed signature: 01 / i • Fee methodology set by Tri-Coanry Building Industry Service Board Print name: /iL ,i Date: 7 j 1111 CITY OF TIGARD MASTER PERMIT • COMMUNITY DEVELOPMENT Permit#: MST2015-00008 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 02/24/2015 Parcel: 2S109DB05900 Jurisdiction: TIGARD Site address: 13293 SW HAZELCREST WAY Subdivision: SEQUOIA HEIGHTS Lot: 7 Project: Sequoia Heights, Lot 7 Project Description: New SF. Sewer connection for lot done previously for temporary sales trailer on this lot. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 1074 sf Basement: 0 sf Left: 5 Parking Spaces: 0 Height: 23 Bathrooms: 3 Second: 1316 sf Garage: 701 sf Front: 15 Smoke Dwelling Units: 1 Third: 0 sf Right: 5 Detectors: Yes Total: 2392 sf Value: $294,781.60 Rear: 15 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 4 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 5 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2392 Owner: Contractor: LENNAR NORTHWEST INC LENNAR NORTHWEST INC Required Items and Reports(Conditions) 15060 SW 133RD AVE 11807 NE 99TH STREET SUITE 1170 1 Ersn Cntrl 503-639-4175 TIGARD,OR 97224 VANCOUVER,WA 98682 PHONE: 360-258-7900 PHONE: 360-216-6423 FAX: 360-258-7901 Total Fees: $22,506.42 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. A • 10 : ` egon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-01 -0010 through 0A• •52-r• -00•• You may obtain a copy of the rules or direct questions to OUNC by cal 232.1987 or 1.800.332.23 Issued By: I ..7 'l 4 A a/ ' ' Permittee Signat re: -/-' �'gill (61." Call 503.639.4175 by 7:00 a.m.for the next available inspection d e. This permit card shall be kept in a conspicuous place on the job site until co. •letion of the project. Approved plans are required on the job site at the time of each inspection. . 3 t • Building Permit Application RECEIVED Residential l 0R 0 I I ICE USE ONLY City of Tigard JAN 6 2015 /©Agre� 1'7'Srax�axeir / Permit No.: a • 13125 SW Hall Blvd.,Tigard,OR 972238 OF TIGARD Pl••' . liTa e� • Phone: 503.718.2439 Fax: 503.598.1 DatdB : '■ a " Permit: ' TIGARD Inspection Line: 503.639.4175 ILDING DIVISIO Dstc Ready Jam: 0 See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ®New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ®1-and 2-family dwelling Valuation: $ ''r `r W ❑Commercial/industrial j ❑Accessory building ❑Multi-family Number of bedrooms: jet ❑Master builder ❑Other: Number of bathrooms: 2 , 5 JOB SITE INFORMATION AND LOCATION Total number of floors: Z Job site address:i 32 Ty 514/ WA zet.4,4 es r IA)4 y New dwelling area: 2, 3'1 2 square feet City/State/ZIP: re;AIR p I OR C/ 72 2 3 Garage/carport area: 7 Q / square feet Suite/bldg./apt.no.: ( Project name: Covered porch area: 56 square feet/3 ffits Cross street/directions to job site: Deck area: square feet 1024 Other structure area: CjOft.3 square feet 'Z3 REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: _5-6 Q u O/A ,Lf( r q H 75 Lot no.: 7 — Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. N S F R Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name:LENNAR NW,INC Type of construction: Address:11807 NE 99"Street,Suite 1170 Occupancy groups: City/State/ZIP:Vancouver,WA 98682 Existing: Phone:(360)258-7900 Fax:(360)258-7901 New: ® APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:LENNAR NW,INC Structural plan review fee(or deposit): Contact name:ERIK.PETERSON FLS plan review fee(if applicable): Address:11807 NE 99*Street,Suite 1170 City/State/ZIP:Vancouver,WA 98682 Total fees due upon application: Phone:(360)258-7900 Fax::(360)258-7901 Amount received: 75 , /51 E-mail:erik.peterson@lennar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name:LENNAR NW,INC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:11807 NE 99"'Street,Suite 1170 Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver,WA 98682 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(360)258-7900 I Fax:(360)258-7901 State surcharge(12%of permit fee): $21.60 CCB lic.: / 1 .j 3 0 7 Total fee due upon application: $201.60 Authorized signature:[ ,....,..„.....Z4 This permit application expires if a permit is not obtained / within 180 days after it has been accepted as complete. Print name: Date: *Fee methodology set by Tri-County Building Industry ���� ��/ " �/V Service Board. I:I Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-46131(11/02/COM/WEB) Electrical Permit Applicatio FOR OFFICE USE ONLY City of Tigard E C E I V E D Received r a G / �, lid„ Permit No.: ilt2T��/�—a,r'�}7 Date/By: !��"� '� 13125 SW Hall Blvd.,Tigard,OR 97223 2 6 Plan Review t ��i�_ gS Q Phone: 503.718.2439 Fax: 503.598.1960.�AN fi 6 2015 Date/By: Other Permit: Inspection Line: 503.639.4175 Date Ready/By: Juris: E7 See Page 2 for I IC AI.D Internet: www.tigard-or.gov RR�� '' CITY OF TIGARD Notified/Method: Supplemental Information TYPE OF'{VDRIIPIG DIVISION PLAN REVIEW Please check all that apply(submit 2 sets of plans w/items checked below): gNew construction ❑Addition/alter ation/replacelnent ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition ❑Other: where the available fault current ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. less to ground,or exceeds 14,000 ❑Commercial-use agricultural ;I-and 2-family dwelling ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings. ❑Fire pump. ❑Installation of 150 KVA or ❑Multi family ❑Master builder ❑Other: ❑Emergency system. larger separately derived system. JOB SITE INFORMATION AND LOCATION ❑Addition of new motor load of ❑"A","E","I-2","1-3", 3Z 1 Six or o e res. R occupancy.r Job no.: Job site address• g �Z EI G(LT w)S y 0 or more residential units. ❑Recreational vehicle parks. ❑Health-care facilities. ❑Supply voltage for more than City/State/ZIP: ---Ti� �p I ®�, �7 Z2 z' ❑Hazardous locations. 600 volts nominal. Suite/bldg./apt.no.: Project name: ❑Service or feeder 600 amps or more. FEE SCHEDULE Cross street/directions to job site: Description I Qty. I Fee. I Total I ' New residential single-or multi-family dwelling unit. Includes attached garage. Subdivision: `� Lot no.: 1,000 sq.ft.or less ( 168.54 4 r _..) - ?u Ol-A- �-i C i-4--('S ' Ea.add'l 500 sq.ft.or portion 45 33.92 1 Tax map/parcel no.: Limited energy,residential 1 75.00 2 DESCRIPTION OF WORK (with above sq.ft.) Limited energy,multi-family N 5F residential(with above sq.ft.) 75.00 2 Renewable Energy ❑ See Page 2 Services or feeders installation,alteration,and/or relocation )) OWNER I ❑ TENANT 200 amps or less 100.70 2 PROPERTY» 201 amps to 400 amps 133.56 2 Name: LE,N N A g-. N IN I J N G . 401 amps to 600 amps 200.34 2 Address: \ ,?)c,---7 1 I G1 —'n S.1- ' S ( l -7 C) 601 amps to 1,000 amps 301.04 2 u l-e c Over 1,000 amps or volts 552.26 2 City/State/ZIP: V CCrU V EZ I Uv 1 5 4, Z Temporary services or feeders installation,alteration,and/or relocation Phone:(3(p� 2_5 S S • �� a o Fax:(3400) 2S2D . -lei°I 200 amps or less 59.36 1 Owner installation:This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits-'new,alteration,or extension,per panel A.Fee for branch circuits with El APPLICANT I ❑ CONTACT PERSON above service or feeder fee, each branch circuit 7.42 2 3usiness name: - S p t.l e _ B.Fee for branch circuits without contact name: service or feeder fee,first 56.18 2 branch circuit kddress: Each add'l branch circuit 7.42 , 2 Miscellaneous(service or feeder not included) iity/State/ZIP: Each manufactured or modular 67.84 2 dwelling,service and/or feeder 'hone:( ) Fax: ( ) Reconnect only 67.84 2 -mail: - Pump or irrigation circle 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 3usiness name: Signal circuit(s)or limited-energy See �g 0 trGH L6C-�R1� panel,alteration,or extension. Page 2 2 ddress: I I o 5-.2, S O NI NI �( 1>J1= Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr :ity/State/ZIP: 14 frc-p \iPS.LLe 1 d Investigation(1 hr min) 66.25/hr Fax: Industrial plant(1 hr min) 78.18/hr 'hone:(50 3) 3 ebo. 5p-3 ( ) Inspections for which no fee is 90.00/hr :CB Lie.: ! 9 5 39 9 Electrical Lic.: G g I I Suprv.Lie.: -¢07o s specifically listed(%:hr min) ELECTRICAL PERMIT FEES N. uprv.Electrician si ature,required: ,�`i� Subtotal: Date: 1 Gt Platt review(25%of permit fee): rint name: �ONYO(2O SLpc\(ETS ' r U I� State surcharge(12%of pennit fee): .uthorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 rint name: Date: days after it has been accepted as complete. ' Number of inspections allowed per permit. uilding■Permits\ELC PermitApp ELR ERE.doc Rev 05/21/2013 440.4615T(11/05/COM/wEB Mecr a hanical Permit Applicrtic FOR OFFICE USE()NIA of Tigard E I V E D ()NIA Received /5 �Date/By: / Date/By: p Permit No.:/7 ,S VC g • 13125 SW Hall Blvd.,Tigard,OR 97221p- 2 6 2015 Plan Review a Phone: 503.718.2439 Fax: 503.598.196U'` 2 Date/By: Other Permit: tQ —� / l' ¢S r 1 c n R 1 Inspection Line: 503.639.4175 Date Ready/By: Iuria: See Page 2 for Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method: Supplemental Information BUILDING DIVISION 1 TYPE OF WORK COMMERCIAL FEE* SCHEDULE - USE CHECKLIST Mechanical permit fees*are based on the value of the work ®New construction ❑Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information use checklist. ❑Multi-family ❑Master builder ❑Other: Description I Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling: `• , Air conditioning 46.75 Job site address: /32)3 S w 1-hi ZG LL'RL15T WA Furnace 100,000 BTU(ducts/vents) I 46.75 City/State/ZIP: 776 API) ` O R Q 7 2 Z 3 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldgfapt.no.: Project name: Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: s(_QU0/A 27L—'/Qh/TS Lot no.: 7 Other: 23.32 1 Other fuel appliances: Tax map/parcel no.: Water heater I 23.32 • DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas NSFR fireplace 23.32 _ Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 _ Chimney/liner/flue/vent 23.32 ® PROPERTY OWNER ❑ TENANT Other: 23.32 Environmental exhaust and ventilation: Name:LENNAR NW,INC Range hood/other kitchen equipment 1 33.39 Address:11807 NE 99th Street,Suite 1170 Clothes dryer exhaust I 33.39 City/State/ZIP:Vancouver,WA 98682 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 5 23.32 Phone:(360)258-7900 Fax:(360)258-7901 Attic/crawlspace fans 23.32 ® APPLICANT ❑ CONTACT PERSON Other. 23.32 Business name:LENNAR NW,INC Fuel piping: W $14.15 for first four;S4.03 for each additional Contact name:ERIK PETERSON Furnace,etc. Address:11807 NE 99th Street,Suite1170 Gas heat pump Wall/suspended/unit heater City/State/ZIP:Vancouver,WA 98682 Water heater I Phone:(360)258-7900 Fax::(360)258-7901 Fireplace I Range I E-mail:erik.peterson@lennar.com Barbecue CONTRACTOR Clothes dryer(gas) �1 Other: Business name: TR I Co NA)-7-7 (;M p t..UN%,D L MECHANICAL PERMIT FEES* Address: 13 j .b--0 S CG A G K/{M/)5 f i✓�iQ De. Subtotal City/State/ZIP: 026:-.6-6,4 CI T ,R. 9 7 0 4 5 Minimum permit fee($90.00) Y Plan review(25%of permit fee) Phone:(6-03) 5 7- 22.76 Fax:(6-113) 55-7- 0 9/9 State surcharge(12%of permit fee) CCB lie.: 72 6 2 3 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: d y (((y * Fee methodology set by Tri-County Building Industry Service Board Print name: Date: I:1Building/Permits 1 MEC_PennitApp_040I13.doc / 440-4617T(11/02ICOM/WEB) Pluming Permit Application ECEIVED Building Fixtures FOR OFFICE USE ONLY City of Tigard JAN 2 6 2015 Received Permit No.: u 13125 SW Hall Blvd.,Tigard,OR 97223 JAN /LQ(p /S flj / �jro'tQ/S ■ Phone: 503.718.2439 Fax: 503.s�I119$6 OF TIGARD Date/By:Review Other Permit No. /4! �� Inspection Line: 503.639.4175 BUILDING DIVISION Date Read B turis: l See Page 2 for I I L 1 R D Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction 0 Demolition For special information use checklist. Description I Qty. I Ea. I Total ❑Addition/alteration/replacement ❑Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(I)bath 312.70 ® 1-and 2-family dwelling ❑Commercial/industrial SFR(2)bath 437.78 building SFR(3)bath 500.32 ❑Accesso ry g ❑Multi-family Each additional bath/kitchen 25.02 ❑Master builder ❑Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: / Catch basin or area drain 18.76 Job site address: 1 3 213 SW 1- A z&.-Leg G S r �'4 y Drywell,leach line,or trench drain 18.76 City/State/ZIP: l/(7/a I D / OR 9 7 2 Z 3 Footing drain(no.linear ft.: ) Page 2 Suite/bldg./apt.no.: I Project name: Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.: ) Page 2 Storm sewer(no.linear ft.:_) Page 2 Water service(no.linear ft.:_) Page 2 Subdivision: SC 4 a,,,,4 /-/ /c H75- I Lot no.: 7 Fixture or item: Tax map/parcel no.: Backflow preventer I 31.27 - DESCRIPTION OF WORK Backwater valve 12.51 Clothes washer 1 25.02 NSFR Dishwasher I 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 ® PROPERTY OWNER 1 ❑ TENANT Expansion tank 12.51 Name:LENNAR NW,INC Fixture/sewer cap 25.02 Floor drain/floor sink/hub 25.02 Address:11807 NE 99th Street,Suite 1170 Garbage disposal I 25.02 City/State/ZIP:Vancouver,WA 98682 Hose bib 2.. 25.02 Phone:(360)258-7900 Fax:(360)258-7901 Ice maker j. 12.51 0 APPLICANT ❑ CONTACT PERSON Interceptor/grease trap 25.02 Business name:LENNAR NW,INC Medical gas(value:$ ) Page 2 Primer 12.51 Contact name:ERIK PETERSON Roof drain(commercial) 12.51 Address: 11807 NE 99th Street,Suite 1170 Sink/basin/lavatory j 25.02 City/State/ZIP:Vancouver,WA 98682 Solar units(potable water) 62.54 Phone:(360)258-7900 Fax::(360)258-7901 Tub/shower/shower pan 3 12.51 E-mail:erik.peterson @lennar.com Urinal 25.02 CONTRACTOR Water closet 3 25.02 Water heater ! 37.52 Business name: W Q LCD TT a cryrl3)N� ' / Water piping/DWV 56.29 Address: / b 75 f. /-l/5-7-0R I C Cp'o 1.UM�►?�),4 Rl✓( /2 yW)/ Other: 25.02 City/State/ZIP: j/2p u�AL L ) O t[ q 76 6,Q / Subtotal L Fax:(5 i1 3) 7. Minimum permit fee: $72.50 Phone:( jo3) 6(c 7�76/ x 3 69? / Plan review (25%of permit fee) CCB Lic.: // 2 2z o Plumbing Lic.no.: Zt . g24P(3 ' State surcharge(12%of permit fee) Authorized signature: TOTAL PERMIT FEE Print name: CL ,--� �U W MA Date: This permit application expires if a permit is not obtained within 180 days / after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. 1:\Building\Permits\PLMU-PermitApp.doe 10/01/09 440.4616T(10/02/COM/WEB) 1111 City of Tigard ■ COMMUNITY DEVELOPMENT DEPARTMENT T n �� Building Permit Review — Residential Building Permit #: N'o2O l 5-0006 8 Site Address: 132'13 SW k{azeicres+ Vk 1 Project Name: SrQjp_, 4 e Lot #: 1 (New dwelling=subdivi on name;Addition or Alteration=last name of owner) Planning Review Proposal: new $[ VVerify site address/suite #exists and active in permit system. Si$ Plan Elements: ree(3)copies of site plan xisting structures on site VP e plan must 12t on 8-1/2"x 11"or 11 x 17"paper :4 Footprint of new structure(including decks)with finished rawn to scale(standard architect or engineer scale) oor elevations ►T. •rth arrow Utility locations(required for new,may apply for additions) $ire address,project or subdivision name and lot number 711 •cation of wells/septic systems V •plicant information(name and phone number) U Erosion control(including drainage-way protection,silt fence F, .t dimensions and building setback dimensions sign,location of catch basin,etc.) i'i Lot area,building coverage area,percentage of coverage and reet names pervious area(applicable if R-7,R-12,R-25&R-40) eet tree size,type and location Property corner elevations(2 foot contour lines if more than 416-41, -sting trees to be retained with drip line,and tree 4 foot differential) protection measures Clean Water Services—Service Provider Letter: (lot platted prior to 9/10/1995): Required: 0/Yes,applicant was notified Received: ❑ Yes L`7 No ❑ No //Land Use Case#: SUP)201�—OWDZ I VAR2O 1 1-1`occo5 Zoning: R-7 t Setbacks: cr L red) Front 2 l ')ear 211 0 S`) Side 5 t(5..)Street Side() t`g'/Garage 2L11 C MI andscape Requirement: 20 % ` � �� .}� k of Coverage Maximum: $Q % t s cov I /4 a4P e '/Building Height: Maximum Height 35 Actual Height 23 �isual Clearance asements ensitive Lands: ❑ Yes 111 No Type Urban Forestry Plan Conditions Met o yej t . Notes: t n<i1L•1 ',_1.,.I �..:.-.i1iL_.Y 49\71(} - 0 A ■ $1 7,• • '.! ■ 0.rou a exitiry3 ,et Gr \71 corne.i • l }- Approved By Planning: % _ CI 1-en t k. ,A Date: (}2611 5 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved I:\Building\Forms\BldgPermitRvw_RES_100I 14.docx Building Permit Submitta Original Submittal Date: / V// Site Plans: # 3 Building Plans: # 3 Building Permit#: e Enter building permit#above. Workflow Routing: Manning 0—Engineering Permit Coordinator ifrT3uilding Workflow Sign-off: al Sign-off for Planning(include notes from planning review) Route Application Documents: I2"E ngineering: (1) copy of permit application, (1) site plan, (1) building plan and on ' al plan review routing form. ..2 Building: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: j/4/,S Date: Engineering Review ❑ Actual Slope: ❑ Conditions Met ❑ Easements (encroachments) ❑ Water Quality/Quantity Facility: Assess Water Quality Fee: ❑ Yes ❑ No Assess Water Quantity Fee: ❑ Yes ❑ No Notes: � �,g rN f G eR -t t�. p o 4_ .5 p is w 14o—u4-C 4 T' JC,c T. Approved by Engineering: Date: ` ,2 7'5 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Permit Coordinator Review Conditions Met-Prior to Issuance of Building Permit Notes: .ge.c�f d <1 e1(A.4 I 4 ' s, rlti,J .c fir.i s l;ne trck.. A ppr • d ) . Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: OK to Issue Permit Approved by Permit Coordinator: 014, a . eak/Lt-✓ Date: ,) -13 -IS 1:\B u i I d in g\Fo rm s\B I d gPerm i t Rv w_RE S_100114.do cx Albert Shields From: Albert Shields Sent: Tuesday, January 27, 2015 1:19 PM To: erik.peterson @lennar.com Subject: MST2015-00008, 13293 SW Haze!crest Way, Lot 7 Erik, On reviewing the site plan, Engineering has the following request: Submit detail for sidewalk at existing tree. Please submit the appropriate detail. Albert Shields City of Tigard 111 : r Permits/Projects Coordinator TIGAR A, Aber;t ard-or.gc. (503) 713-2426 • (503)624.3631 13125 SW ma Blvd. Tigard,OR 97223 1 • MAY 302014 NOTICE OF TYPE I DECISION BY: DEVELOPMENT ADJUSTMENT (VAR) 2014-00005 ill SEQUOIA HEIGHTS LOT 7 TIGARD 120 DAYS = 08/12/2014 sPa001-4 SECTION I. APPLICATION SUMMARY FILE NAME: SEQUOIA HEIGHTS LOT 7—SETBACK ADJUSTMENT CASE NO.: Development Adjustment(VAR) VAR2014-00005 PROPOSAL: The applicant requests approval for an adjustment to reduce the street side yard setback requirement from 10 to 8 feet on Lot 7 of the Sequoia Heights Subdivision (SUB2013-00002). APPLICANT Lennar Northwest,Inc. AND OWNER: 1807 NE 99th Street,Suite 1170 Vancouver,WA 98682 ZONING: R-7: Medium-Density Residential District. The R-7 zoning district is designed to accommodate attached single-family homes, detached single- family homes with or without accessory residential units, at a minimum lot size of 5,000 square feet, and duplexes, at a minimum lot size of 10,000 square feet. Mobile home parks and subdivisions are also permitted outright. Some civic and institutional uses are also permitted conditionally. LOCATION: Sequoia Heights Subdivision, Lot 7; 15060 SW 133'd Avenue; WCTM 2S109DB,Tax Lot 00800. • APPLICABLE REVIEW CRITERIA: Community Development Code Chapter 18.370.020.B SECTION II. DECISION Notice is hereby given that the City of Tigard Community Development Director's designee has APPROVED the above request.The findings and conclusions on which the decision is based are noted in Section IV. THIS APPROVAL SHALL BE VALID FOR 18 MONTHS FROM THE EFFECTIVE DATE OF THIS DECISION VAR2013-00005 Sequoia Heights Side Yard Adjustment Decision Page 1 of 5 SECTION III. BACKGROUND INFORMATION Site History and information. The application is for lot 7 of Sequoia Heights (SUB2013-00002), an approved 14 lot subdivision located at 15060 SW 133`d Avenue,WCTM 2S109DB00800. As approved,Lot 7 would be located at the northwest corner of the subdivision,at the future intersection of 133`d Avenue and SW Hazelcrest Way. Proposal Description: The applicant requests an adjustment to reduce the street side yard setback by 2 feet, or 20% of the minimum required,in order to construct a new single family home SECTION IV. APPLICABLE REVIEW CRITERIA AND FINDINGS COMPLIANCE WITH COMMUNITY DEVELOPMENT CODE SECTIONS: RESIDENTIAL ZONING DISTRICTS (18.510) TABLE 18.510—DEVELOPMENT STANDARDS IN RESIDENTIAL ZONES STANDARD—R-4.5 ZONE Standard Proposed Minimum Setbacks -Front yard 15 ft No change -Side facing street on corner&through lots 10 ft 8 Ft. -Side yard 5 ft No Change -Rear yard 15 ft No change -Distance between property line and front of garage 20 ft No change DEVELOPMENT ADJUSTMENT—APPROVAL STANDARDS: Section 18.370.020.B.1.b provides that up to a 20% reduction of the dimensional standards for the side yard setback required in the base zone may be approved as a Type I Development Adjustment. DEVELOPMENT ADJUSTMENT—APPROVAL CRITERIA: Section 18.370.020.B.2, Approval Criteria, provides that a development adjustment shall be granted if there is a demonstration of compliance with all of the applicable standards: a. A demonstration that the adjustment requested is the least required to achieve the desired effect; The applicant has requested, a 20% reduction in the required street side yard setback of 10 feet,reducing the side yard setback to 8'. All other setbacks will be adhered to. The purpose of the adjustment is to accommodate a particular housing design, as demonstrated in the attached plot plan. The adjustment is being requested now, rather than with the original subdivision approval, because an additional two feet of right-of-way dedication was required along 133`d avenue as a condition of approval of the subdivision. This condition resulted in an unexpected narrowing of the lot from 66 feet to 64.37 feet in width. As demonstrated in VAR2013-00005 Sequoia Heights Side Yard Adjustment Decision Page 2 of 5 the site plan, the proposed structure will extend into the required setback by approximately '/2 foot (5% of the required setback) rather than the full 2 feet (20%) requested, and appears to be the minimum amount necessary.This criterion is met. b. The Adjustment will result in the preservation of trees, if trees are present in the development area; No trees will be removed due to this construction and there are none that need protection. This criterion does not apply. c. The Adjustment will not impede adequate emergency access to the site; The Adjustment for a side yard setback will not impede emergency access on or across the property. This criterion is met. d. There is not a reasonable alternative to the Adjustment which achieves the desired effect. Adjustment of the interior side-yard setback with this housing design is not possible to the location of utility boxes that prevent movement of the associated driveway entrance. This criterion is met. FINDING: Based on the analysis above,the adjustment approval criteria have been satisfied. SECTION V. PROCEDURE AND APPEAL INFORMATION Notice: Notice was mailed to the applicant and owners. Final Decision: The decision of the Director on Type I Procedure is final on the date it is mailed or otherwise provided to the applicant, whichever occurs first. The Director's decision may not be appealed locally and is the final decision of the City. THE DECISION IS FINAL ON MAY 28, 2014 AND BECOMES EFFECTIVE ON MAY 29, 2014. Questions: If you have any questions, please call the staff person below or stop by the Planning office at the Tigard Permit Center, 13125 SW Hall Boulevard,Tigard,OR 97223. II"— May 28,2014 4, p ved by: John Floyd Date G Associate Planner 503-718-2429 johnfl@tigard-or.gov tigard-or.gov VAR2013-00005 Sequoia Heights Side Yard Adjustment Decision Page 3 of 5 PLOT PLAN LOCATED IN THE SOUTHEAST QUARTER OF SECTION 9, TOWNSHIP 2 SOUTH, RANGE 1 WEST, WILLAMETTE MERIDIAN, WASHINGTON COUNTY, OREGON I � c m 4Y E n �N N g DOC. NO. 2004-064783 2'00 ^r N89'52'00 11 440.54' I f ''1 64.37' I 25' Ir.-8.00' PUE • • POTENTIAL HOUSE . ;:`. FOOTPRINT 2.00' ROW--- rf-- . DEDICATION I 51.37' _ _ ---5.00' R7 8.00' PROPOSED SIDE YARD I o STREET SIDE _ I S SETBACK YARD SETBACK j 7 0 6 10.00' R7 5,430 SF 5,t0O Sr Z STREET SIDE M YARD SETBACK o ti 49.37' . _ \--- -- --- CC I ; r,i..,'� 1 J o 0 ,/ co ` CV \\:: ..,_ CI - U) `�' ' L a ., F ���^-, 50.47' 1 U. v 0 �1 b -C1 ay C m p 3 Lb C Z L=21.89' o r 3 LL 4 SW HAZEL_CREST WAY o 1 CO o T ? "• / N89'52'001 355.43' - _ > 'L C O p - n o W d o T SCALE 1" = 20 FEET Q u.&ti) -m IMO NI PREPARED FOR 20 0 8 12 16 20 DATE:02/25/14 LENNAR HOMES SEQUOIA HEIGHTS 3346 022514 PLOT 11807 NE 99TH STREET, SUITE 1170 DRAW"! BY:JOHICHECKE°BY:MS IDWI;:PLAN-WITH FOOTPRINT k,106: 3346 VANCOUVER, WASHINGTON 986B2 AKS ENGINEERING & FORESTRY, LLC 1AMLS 13910 SW GALBREATH DR SUITE 100 SHERWOOD, OR 97140 www.oks-eng.com PHONE: 503.925.8799 FAX: 503.925.8969 VAR2013-00005 Sequoia I Ieiihts Side Yard Adjustment Decision Page 4 of 5 ..fl /.... . ..•!.• - . 11 v, '; A t f '?• , ,., :,,,,, , t 9i Ci) 1 i 1 5 i•-., 8 i ' .; ' •:::••' s ■••• - . C 1?! .. _ LE •3 7 Iv 6, P t : r.-.. -,..)-, .s.., c • , .• ,,,, :, P ' (-I-' 4i115, :k :: ,;'. J -I I; . ., -.1..p:• -.- N E ti r., III . F\\' • ‘2... • '• - --. . ' •....••. .... co• In N I vm 1- i N 0 Dvio u) 0 U rs. fr — ir 0 1 DI--p Lu ,0 N 7.,..35 ‘1: I :r. co• 1 i a II i Ii3.1. ONZ£1. a .....N•••• ••■•••■•■•6"11111111111••••••■■■•••••••01"•••• I i I 1 i 1 * I I e . r s g ..•.,....... p i P II p 1 !1 P p 1 I )1 ... 3AV CLUI • ... 0 .-, • • . • I I 1 CD VAR2013-00005 Sequoia Heights Side Yard Adjustment Decision Page 5 of 5 Zen Dutson From: Zen Dutson Sent: Monday, February 23, 2015 9:52 AM To: 'Mike.Loomis @Lennar.com' Cc: Albert Shields Subject: MST2015-00008 Attachments: IMG_2963.JPG; IMG_2964.JPG; IMG_2965.JPG; 20150220092614953.pdf; Sidewalk Extensions.pdf Importance: High Mike Here is the APPROVAL for the sidewalk extensions. We added a detail to eliminate the pointed part of the planter because it's difficult to maintain. Thanks, Zen Original Message From: Michael Loomis [mailto:Mike.Loomis@Lennar.com] Sent: Friday, February 20, 2015 9:51 AM To:Jeffrey Hess; Charles Webb; Erik Peterson;#CD PoD Cc: Michael Loomis Subject: FW: Importance: High All: Attached hereto, please find the schematic plan for the sidewalk extensions for Sequoia Heights Lots 1, 7 &8. As noted on the plan, all subject walks need to be transitioned from planter strip to curb-tight walks due to existing trees that were preserved at all three locations. Elevations are set based on the existing, prior-approved sidewalks and curb that were installed during public improvements. I have also included some pictures showing the existing conditions and trees. Please let me know if you have any questions and/or need additional information. Thank you, Mike Mike Loomis Director of Land Development Lennar Northwest, Inc. mike.loomis@lennar.com www.lennar.com Office: 360-258-7900 Cell : 503-519-6147 Fax: 360-258-7901 1 Zen Dutson From: Zen Dutson Sent: Wednesday, January 28, 2015 5:59 PM To: 'Erik.Peterson@Lennar.com' Cc: Albert Shields Subject: FW: MST2O15-00008, 13293 SW Hazelcrest Way, Lot 7 Erik, The sidewalk needs to extend to the lot line even though it wasn't caught during development construction.The code requires it. Use an "S" curve to end the sidewalk over to be against the curb at the property line. During the past year the City has directed not to leave sidewalks gaps such as this. This was a fast paced development& unfortunately the gap didn't come to our attention soon enough. And it's certainly not fair to push it on to the adjacent property when future improvement occurs. Thanks,Zen From: Erik Peterson [mailto:Erik.Peterson©Lennar.com] Sent:Tuesday,January 27, 2015 4:14 PM To: Albert Shields Subject: RE: MST2O15-00008, 13293 SW Hazelcrest Way, Lot 7 Albert, Per the approved plans (please see attached)the sidewalk improvements end well short of the tree location. I think that the submitted site plan for Lot 7 permit confused the matter, we can resubmit a new site plan that correctly shows the end of the sidewalk, if needed. Thank you, Erik LENNAR Erik Peterson Director of Architecture Lennar Portland eri k.Peterson P LE N NAR.com www.LENNAR.com Office: 360.258.7900 Direct: 360.258.7876 11807 NE 99th Street,Suite 1170 Vancouver,WA 98682 You 1 Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13293 SW HAZELCREST WAY, TIGARD, OR, 97224 Residential - Master Permit 199 Electrical final FAIL MST2015-00008 David Young Work not complete. Receptacle and cover missing in garage by mechanical room door. Receptacle and boxes not secured in kitchen. 314.20, 21, 22, 23. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13293 SW HAZELCREST WAY, TIGARD, OR, 97224 Residential - Master Permit 199 Electrical final PASS MST2015-00008 David Young Correction done. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13293 SW HAZELCREST WAY, TIGARD, OR, 97224 Residential - Master Permit 299 Final inspection FAIL MST2015-00008 David Young Provide final PLM for backflow devise. Provide ELC final for change of contractor. Provide approved mechanical final with AC added to permit. Provide approved building final inspection. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13293 SW HAZELCREST WAY, TIGARD, OR, 97224 Residential - Master Permit 699 Mechanical final FAIL MST2015-00008 David Young Add ac to existing permit. All else ok. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13293 SW HAZELCREST WAY, TIGARD, OR, 97224 Residential - Master Permit 699 Mechanical final PASS MST2015-00008 David Young Correction done. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13293 SW HAZELCREST WAY, TIGARD, OR, 97224 Residential - Master Permit 399 Plumbing final PASS MST2015-00008 David Young Corrections done. Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13293 SW HAZELCREST WAY, TIGARD, OR, 97224 Residential - Master Permit 299 Final inspection PASS - C of O MST2015-00008 David Young Final erosion control approved. Street tree certification received. Moisture content form received. High efficiency lighting form received. Duct seal test report checked. Insulation certification checked. C of O left on site. Note: drainage swale installed at left side of house below sidewalk. Violation Summary: Inspector Contractor