Loading...
Report -�, RECEIVED Carrier (�w FEB 10 2015 co united Technologies CITY OF TIGAR BUILDING DIVISION SUBMITTAL Project TruGreen Date Wednesday, December 17, 2014 CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: 4-44:4- 4e s rwA 1rx4 kttA OTC: Permit#: Address: 75 b Suite#: By: ��-----� Date: • Table Of Contents Project: TruGreen 12/17/2014 Prepared By: 08:51 PM Untitled/ 3 Unit Report 4 Certified Drawing 5 Performance Summary__ 8 cr nOi i TIC+' s.ovau`IMo:}auoD 1101 aavatvan I l ;PTO giV4 1;61121 2iiu2 M1sQ — t� Packaged Rooftop Builder 1.39m Page 2 of 10 Untitled1 Project:TruGreen 12/17/2014 Prepared By: 08:51 PM Untitled1 Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.39m Page 3 of 10 • Unit Report For UntitledI Project: TruGreen 12/17/2014 Prepared By: 08:51 PM Unit Parameters Dimensions(ft. in.)&Weight(lb.)*** Unit Model: _ 48TCDA05A2A5-0A0A0 Unit Length:_.._ _.._.___.. __. 6'2.375" Unit Size: 05(4 Tons) Unit Width. 3'8" Volts-Phase-Hertz. 230-3-60 Unit Height T 9.375" Heating Type: Gas ••• Total Operating Weight: 547 lb Duct Cfg Horizontal Supply I Horizontal Return Low Heat "' Weights and Dimensions are approximate. Weight does Round Tube Plate Fin Coils not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size.. ...... . . 1/2 Condensate Drain Line Size. 3/4 Return Air Filter Type. Throwaway Return Air Filter Quantity: 2 Return Air Filter Size. 16 x 25 x 2 Unit Configuration Medium Static Option Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA05A2A5-0A0A0 Rooftop Unit 1 Base Unit None None Packaged Rooftop Builder 1.39m Page 4 of 10 Certified Drawing for Untitled1 Project TruGreen 12/17/2014 Prepared By: 08:51PM NOTES: UNITED ••O.NON ANON NOu KCNKNT II TEE rp10Nn HO CANDIED CA•ONAIINN TECHNOLOGIES 41NACINE.NO AN I6 NOLIONEN NlOE THE[1110[1 CO[NITICN"'TNT [DOESE6ADT CM[i11UEI/Alf r[MOANANC[CO 1.DIMENSIONS ARE II INCHES,DIMENSIONS UNIT 1 X CARRIER ISM CONnn/nu NOr NE DIARNOEDd N[[N NI TNNOT CANOI[N ACC[rtAK[a CNOTNACT. IN I I ARE IN MILLIMETERS. 33 3/0 18 SIT caArpula•4 wtnd cONSE AT. 481C-A04 1817] [1121 2.• CENTER OF GRAVITY 33 318 14 716 481C-A05 CDIINECT IOM SIZES 1811] [3711 A 1 378. 1351 DIA FIELD POWER SUPPLY ROLE 3.y DIRECTION or AIR FLOW 481C-A06 33 3/8 14 7/8 18171 13711 A 2' 1501 DIA POWER SUPPLY NNOCNOUT 48TC-407./1 710 11 7/8 C 1 3/4' 151]DIA GAUGE ACCESS PLUG 110511 13111 - D 7/8' 1221 DIA FIELD CONTROL AIRING HOLE t-- 10401 18 E 3/4'-14 NPT CONDENSATE DRAIN 816 [ 1!2'•11 APT GAS CONNECTION • I ■ • ---f 6 2 1/2' 1641 DIA POWER SUPPLY NIKKX-OUT 32.114 ECONOMIZER HOOD li 1818] [OPTIONAL) [40i] FILT/183LCLES7]ANEL CONP. I ♦ THESE HOLES REQUIRED FOA NSF CONDENSER CAATNPWR001A01,IO3A01 • - ACCESS I COIL THREADED R1RE REO'D HOLE -PA II INDOOR COIL - - - - [ CONDUIT SIZE USE SI/ES IRAN.) ACCESS PANEL \ I Ill' ACC. 7/8' 122.21 © / --- ' 10.716 1 r 112' 248 7/D' 122.27 ///�///�/ \\1 is-s/e _ _ H!IIIII \ RDIANE AIR E2111 R N E 3/4' 1001,0031 POWER 1 1/6' [28.41 Y'11161)♦-1 —��•1•] 44 •'1'1W'' �'/,1 ll _ AIR ZIN 46031 112'OPT GAS i 3116' 130.01 I£ 111171 1\\�� /���� 0 I ION'711A-TIE-DASEPAN'FACTORY OPTION, 2-5/8.-I - /// I IITTIN6S FOR ONLY X.Y. 6 Z ARE PROVIDED•BACK 1671 __ is E ALT.v O SELECT EITHER 3/4'OR TIP•TIP ^W CONDENSATE ' N FOR PURER. DEPENDING Ca WIRE SI2E WIDTH - -- •k DRAIN OPENING [45111 NN 10011 PROVIDES 3/4.OPT 11119 CURB IN BASEPAN 20-318 CURB T 1` ,i SUPPLY . 26-1/2 17/71 FLANGE 6 FITTING. 10-1!1 I J AIR E6135 AIRPIT 145!1 I • I I AIR 1 18.113 f1-171 12-111 7 r 5 III! f11�1 [1131 iii;;4 SEE T f'� -511 t !1 J� 11571 ` �J r ••— 3-3/8 —.+ 11-iq (A51 25 L\,-FLUE 136T1 ~ 16361—^ 1101] NOON "'—11.112-+ .'— N TOP 11111 4-5/6 10.5/1 1-1/4 11181 12651 1321 • 1EC70Ul ,�' .. �,� •E- __ 1 DISCONNECT - ----- _= LO[A71011 CONDENSER —— �II CONTROL BOA • INDOOR BLOWER E STD.COtI °_A. ACCESS PANEL ACCESS CONDENSSATE I ILTER =6 253116 t U OUTSIDE OPTIONAL =- • I ® { 16-3J4 1 I 6[TUAN I i _ AIR INSTALLED — 111 A] FACTORRY �„ ADDLE 121118 SIPPLYIAll I AIR I ` �� CONVENIENCE _-=--•.=.• INSTALLED 2531] OUTLET == DISCONNECT O ,/ 11.91 I ii�� _�� nun , JI 0 A .-£ II1. 0O�j 11551 3-3/4 H ANDLE U-3/U U 6-518 7 6 3 1151 163/1 ■ 30-1/8 12131 11651 11711 11521 11187] [7641 16-311 148381 14111 31.111 BARCNETRIC 1 RELIEF 7131 LOR LIFT AIR ft RETURN FRONT AIR RIGHT 3NIET Not 7NOPCCIE7 48TC 04-07 SINGLE ZONE ELECTRICAL 4811/500993 101 1 OF 2 11-24-08 09-29-08 COOLING WITH GAS HEAT 5. 0 Packaged Rooftop Builder 1.39m Page 5 of 10 Certified Drawing for UntitledI Project: TruGreen 12/17/2014 Prepared By: 08:51 PM UNITED 1.0.00X 1.w 1.11 00(w1N1 11 III/00/0110 01 CAw111*0010ellw mutual 01 11111 010/1116[C0 OC(wE11S lE(HNOLOGIES 311+(10[.A 10(1 Of lIOtl00 UBM 111 059 0R(wM IIN I1(114 lots w1[**11101[10/1 110(010000 OR STD.UNIT CORNER CORNER CORNER COINER CARRIER 0221 CO1rtR3 tlll MI BE DESOlf6r0 0...0 N1TIg1T CANIf1 N(V101(t OR C101000 UNIT WIGHT RI6NT (0/1 11E1GNi III 0016112 (C) BEIGNT ID) C.G. NEIGNT tOwwula'S MIMEO(Mfr. LBS. 30. LBS. 116. LBS. 39. LBS. NG. LBS. 00. I T I 4876A64 463 216 111 51 125 SI 131 59 116 53 30 19611 23 15841 16 3/6 11161 411C-805 531 I44 124 56 136 63 115 66 126 59 39 16911 23 15841 IT 11321 4171C-A/6 569 256 131 59 147 67 151 70 137 62 39 19911 23 15811 17 1/1 11361 INTC-ANT 652 211 150 611 169 76 176 80 157 71 36(9611 23 15841 20 1/8 15111 CORNER A CORNER B 0 'I ' ItS) ) . CORNER D CORNER C x TOP 1• •1 • t jIiiI 0 1 1 .C]: • 00 FRONT 611[[1 411 1H01Ew1 48TC 04-07 SINGLE ZONE ELECTRICAL g8TM500993 REO 20r2 11-24-08 09-29-08 COOLING WITH GAS HEAT 5- 0 Packaged Rooftop Builder 1.39m Page Certified Drawing for Untitled1 Project: TruGreen 12/17/2014 Prepared By 08:51 PM Service Clearance %. 1 .: "N./ ' l. 00133, LOCATION DIMENSION CONDRION 48-in(1219 mm) •Unit disconnect is mounted on panel-- A 18-In(457 mm) •No disconnect,convenience outlet option •Recommended serviceckarance 12-in(305 mm) •Minimum clearance 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall) 8 36-In(914 mm) 'Surface behind sencer is electrkally non-conductte(e.g.,wood,fiberglass) Special 'Check for sources of flue products within 10-ft.of unit fresh air intake hood C 36-In(914 mm) •Side condensate drain is used 18-In(457 mm) •MINmum clearance 48-In(1219 mm) •No flue discharge accessory installed,surface is combustible material 42-in(1067 mm) •Surface behind servtcer is grounded(e.g.,metal,masonry wall,another unit) D 361n(914 mm) •Surface behind servicer is electrically non-conducthe(e.g.,wood,fiberglass) l •Check for adjacent units or building fresh air intakes within 10-ft.of this unit's Specia flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. Packaged Rooftop Builder 1.39m Page 7 of 10 Performance Summary For Untitled1 Project: TruGreen 12/17/2014 Prepared By: 08:51 PM Part Number:48TCDA05A2A5-0A0A0 ARI SEER . .. . ......................13.00 Base Unit Dimensions Unit Length• 74.4 in Unit Width- 44.0 in Unit Height 33.4 in Operating Weight Base Unit Weight 537 lb Medium Static Option. 10 lb Total Operating Weight 547 lb Unit Unit Voltage-Phase-Hertz- 230-3-60 Air Discharge Horizontal Fan Drive Type: . Belt Actual Airflow 1450 CFM Site Altitude 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB 80.0 F Evaporator Entering Air WB• 67.0 F Entering Air Enthalpy 31.44 BTU/lb Evaporator Leaving Air DB• 59.0 F Evaporator Leaving Air WB• 56.8 F Evaporator Leaving Air Enthalpy:_ 24.26 BTU/lb Gross Cooling Capacity 46.84 MBH Gross Sensible Capacity. 32.82 MBH Compressor Power Input 3.31 kW Coil Bypass Factor 0.229 Heating Performance Heating Airflow 1450 CFM Entering Air Temp 70.0 F Leaving Air Temp 107.7 F Gas Input Capacity: 72.0 MBH Gas Heating Capacity 59.00 MBH Temperature Rise. 37.7 F Supply Fan External Static Pressure. 0.50 in wg Fan RPM' 883 Fan Power 0.55 BHP NOTE: Selected IFM RPM Range: 770- 1175 Electrical Data Voltage Range 187-253 Compressor#1 RLA 13.7 Compressor#1 LRA 83 Indoor Fan Motor Type:_ MED Indoor Fan Motor FLA 5.2 Combustion Fan Motor FLA(ea)- 0.48 Power Supply MCA. 24 Power Supply MOCP(Fuse or HACR): 30 Min. Unit Disconnect FLA 23 Min. Unit Disconnect LRA• 106 Electrical Convenience Outlet None Packaged Rooftop Builder 1.39m Page 8 of 10 Performance Summary For Untitled1 Project: TruGreen 12/17/2014 Prepared By: 08:51 PM Outdoor Fan [Qty/FLA(ea)]. 1 /1.5 Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 84.0 80.6 90.9 125 Hz 76.5 72.7 84.6 250 Hz 64.8 59.6 79.5 500 Hz 57.9 56.0 77.9 1000 Hz 59.1 54.9 76.5 2000 Hz 56.4 51.4 71.1 4000 Hz 57.1 50.4 66.9 8000 Hz 53.4 50.1 62.5 A-Weighted 66.6 62.4 81.0 Advanced Acoustics O It 0 �O O O Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver:_ 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction• 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 90.9 84.6 79.5 77.9 76.5 71.1 66.9 62.5 92.4 Lw B 64.7.68.5 70.9 74.7 76.5 72.3 67.9 61.4 80.8 LwA C _58.5.52.2 47.1 45.5 44.1 38.7 34.5 30.1 60.0 Lp D 32.3 36.1 38.5 42.3 44.1 39.9-35.5 29.0 48.4 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.39m Page 9 of 10 Performance Summary For Untitled1 Project: TruGreen 12/17/2014 Prepared By: 08:51 PM Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 20 \ ,, . 18 16 im'-i ,= - Mil Mak I= . : MEM 11110/ ,_, pm 2 iii is: - fl 7COFPM cn BEM MIM IL 930RFM MOM Milltlk- . IEN us 02 man iiiiIIIIIIIIIIIIIIIIIIIIII IMMIIMIMM 1.0081-12'NI•CO CO 03 06 CO 12 15 18 21 24 Air low(CFM-thousands) RPM=883 BHP=0.55 MaximumBHM=1175 MaximumBHP=2.40 Note:Pleasecontactapplicationengineelingforselectionsoutsidetheshadedregian SC-SystemCurve RP-RatedPoint Packaged Rooftop Builder 1.39m Page 10 of 10 Certified Drawing for Untitled1 Project: TruGreen 12/17/2014 ,Prepared By: 08:51 PM NOTES: 30(1(2 P.R.IN AIM rill AUCA7NT a INS PNnnt a CNnu CUPOAAIIa N DIMENSIONS ARE IN INCHES DIMENSIONS _UNIT J N i fFi 7ECNNOL06)ES t+I+CAAF.n '�lA AulxwA oNC c'C 00(00 Cawltu t S MI S `66•UCQ tINt!APNT ALNOIMR2 wA IN( I ARE IN IN INCHES, 'N"/CARRIER toll cenfnt me 117 6F 0111001 N usro ntat unlu .cc11.1 c ar alMACI. ]]310 18 5/0 CaIraA7l01't 077711 Cp15(At. 48%404 !0117 [1721 2.fli CENTER Of GRAVITY /OTC-005 33 3/8 14 7/8 CONNECTION SIZES 10477 []771 A 1 3/0' 1351 DIA FIELD POWER SUPPLY HOLE 3.Imp,DIRECTION OF AIR ROW 48TC•A06 33 310 II 110 (0111 13171 0 2.1501 DIA POWER SUPPLY KNOCKOUT 48TC407 11 311 11 1/0 C 1 3/4'1517 DIA GAUGE ACCESS PLUG 11051] [7711 D 1/0 1221 DIA FIELD CONTROL WIRING POLE 33-318 1-4-- 18481 E 3/4'-14 OPT CONDENSATE DRAIN A 1(2'•14 NPT GAS CONNECTION • . ---f 6 2 112'1641 DIA POWER SUPPLY KNOCK-OU1 32.111 ECONOMIZER HOOD 18181 [OPTIONAL) 16 [4067 F tLTER ACCESS PANE[ TNAU-THE-BASE CHART I700L-LESS[ COOP I ♦ I THESE HOLES RESPIRED FOR USE • ACCESS CONDENSER DENSER .. •. _ . . . �, ( CPBTNP0030IA01, 003AO1•PANEL I THREADED WIRE REO'D MOLE 100000 COIL S CONDUIT SIZE USE SIZES 1011.1•I ACCESS PANEL % \\ L{ W 1!2' ACC. 7/0'122.21 \����� 25-5/0 10.1/6 A If?' NY TIO'(22.27 -—_ p I—_—_ ♦ ' �( TURt7 - (2111 RETURN / • S/4. 1001,0031 POWER 1 110. 128.A7 I".— RETURN AIR Ia3Af!♦f>♦1�— �03101�'i 44 •'1,111 71` / ��' „ AIR ZN. (1071 1/Z'PRO GAS 1 3f lf' (30.01 111171 ,� / i FOR'TMRU•TNE•OASEPAN'FACTORY OPTION, 2-5/8 / . I Flill N65 FM ONCE 1.1, 0 Z ARE PROVIDED BACK 1611 E ALT. SELECT EITHER 3/1.OR TIP TYP Jr CONDENSATE ' ' FOR POWER. D[P(NDIM6 ON WIRE SIZE CURB DRAIN AIM OPENING tl-3/I CIDTN [1511 PP (001)PROVIDES 3/1•FPT 1NRU CURB 2 IN DAWNS SUPPLY 26-1/2 !11710 FLANGE 6 PITTING. 18-UI 1 11 AIR 16737 SUPPLY _ 70-1/ 1 AIR 10-I/R 11-I/1 12-111 _ 01111 (3031 (3121 SEE TARS THE 8- N 1 1 1 BASE CHART •• i 1571 . V l-3!e 12•110 [85) 25 Elb\--f LOE ~, [3071 [6361 HOOD —10.112+t [100] f K TOP 11101 4-516 10-I12 '•P-. 11101 12657 1 / I 132-I 1 l LSCTgECT 1 1 LOCATION ' `� Iv LOCATION I • Ti CONDENSER CONTROL 001 INDOOR BLOWER OIL A. ACCESS PANEL ACCESS E STD— I llTER B COMDE NSATE G DRAIN t5 1!B 1438) OUTSIDE OP7]OIAL • 16-311 RETURN AIR• FACTORY OPTIONAL I/tll AIR ��__ 11.1/I ll 11-3/8 CONVENIENCE I 11013 INSTALLED IONAL IL t ANDLE SUPPl7 AIR OUTLET DISCONNECT i 1 [ 21.1/1� ---- I 6-5/R IS3f1 (= —1il6El 11611 X00 i�� �: OOs 11551 11 -+— 3-3/4 : HANDLE 8-3/8 1—4•6-5/0 I-i t 6 I051 /6-311 30-1/8 12131 11681 11521 111071 17641 11-3!0 26-3(4 118081 11811 31-1/4 BAROMETRIC (7031 RELIEF LEFT SUPPLY FLOW 4 FRONT AIR AIR RIGHT 1141(1 WI IAPCCCK3 - 48TC 04-07 SINGLE ZONE ELECTRICAL 4870500993 PCI I OF 2 11-24-08 09-29-08 COOLING WITH GAS HEAT 5. 0 Packaged Rooftop Builder 1.39m Page 5 of 10 Certified Drawing for Untitled1 Project: TruGreen 12/17/2014 Prepared By: 08:51 PM VV UNIT ED O61E5 P6.R Ra.n s Raa1 EISla3 i rYi l ll s O rram n a d s l c aUtx[mwroI a F maa Ltt E aa P Aan 0R0en STD UNIT CORNER CORNER CORNER CORNER CARRIER ItAI Rr0a[Os05n x C.6. HEIGHT UNIT WEIGHT HEIGHT(Al WIGHT 161 111611 ICI WEIGHT IDI LBS. KG. LBS. R6. LBS. KG. LBS. RU. LBS. 16. R 1 Z 461C-A04 463 211 111 50 125 51 131 59 116 53 39 11111 23 15641 16 3/6 14163 431C-4/5 531 244 124 56 131 63 145 66 121 51 39 19111 23 15611 17 1432] 461C-406 S69_ 258 131 59 147 67 154 10 137 62 31 19911 23 15641 11 1/4 14361 4$1C-407 652 216 150 68 161 76 176 60 151 71 31 1111)23 15641 21 1/1 15111 CORNER A CORNER B 0 ill\ ®/ y • CORNER D CORNER C R TOP • • s0 jIiI O I �: : OO FRONT MCI 1.n 44r[ACINR 48TC 04-01 SINGLE ZONE ELECTRICAL 48TN500993 2042 11-24-08 09-29-D8 COOLING WITH GAS HEAT 5. 0 Packaged Rooftop Budder 1.39m Page 6 0 • • SITE PLAN P L L./ ei Jc\\ Li Strew,' Per T3r-c.-e i 3(:9 I /411 in Cog ROT Rcs p-r ` LcActc.e,r 9 Ali P L - Zexxe, .n s i 1 PL/ Iv E a'. o au 3 v STREET vs. Rukftec sr y .4+ • NOTE — Please show the following on the site plan: •:• Location of Indoor Unit and Outdoor Unit •:• Indicate how the flue will be run (thru the roof— out the sidewall — etc) •:• Indicate with dotted line how the lineset will be run and approx. distance •:• Indicate how the condensate will be run S ■ 7500 SW Tech Center Drive pecialty Suite X130 Tigard,OR. 97223 HEATING&COOLING INC. (503)620-5643 Fax:(503)681-0793 www.specialitvheatinst.com Ilu'rc not comfortable until you ore! • Product 48DJD/DJE Data Single-Package Rooftop Units Carrier Electric Cooling/Gas Heating HEATING•COOLING 3 to 12-1/2 Nominal Tons Single-Package Rooftop Units with the Following Premium Features as Standard: • 2-in. return-air filters • direct spark ignition • induced draft fan • Turbo-tubular— heat exchangers • solid-state controls • full-perimeter base rails • high-pressure, low-pressure/loss- of-charge cutout switches and freeze protection thermostat • corrosion-resistant condensate pan with internal trap • • refrigerant filter driers • galvanized steel cabinet with painted protection on externally r ::;:<., ,'s .x• >, exposed surfaces e., � s • motors with permanently lubricated ,ha•'• a •:;r r ball bearings •.•try ,..• „o, rte•... ;... _ _ `4 y 16 J�'y } Features/Benefits - Compact, vertical discharge units easily convert to �£ s ' F horizontal discharge, com- r# R ' � '� bining installation flexibility -- with efficient performance and easy maintenance Easy maintenance and installation All units are factory shipped in the ver- tical discharge configuration for fit- up to standard roof curbs. (One accessory curb fits sizes 004-007; an- other accessory curb fits sizes 008- 014.) The contractor can order and install the roof curbs early in the con- struction stage, before decisions on size requirements have been made. All units feature roll-formed baserail qp design with forklift slots and rigging holes for easier maneuvering. Stretch- wrap packaging protects the unit during shipment and storage. Copyright 1991 Carrier Corporation Form 48DJ-4PD r Units are easily converted from�verti- The induced draft combustion'sys- protection switch which allows opera- cal to horizontal applications to make tern eliminates the unsightly,appear- tion at lower ambient conditions retrofit and add-on jobs easier'To ante of flue stacks, and diminishes while protecting against low-charge op- convert from vertical to horizontal dis the effects of winds on heating opera- eration; 2) freeze protection thermo- charge, simply move 2 panels. The tion. The inducer fan draws hot stat, which protects against evaporator same basic unit can be used for a vari- combustion gas through the heat ex- coil frost build-up; 3) high-pressure ety of applications and can be quickly changer at the optimum rate for the switch, which protects against above • modified at the jobsite. most effective heat transfer normal operating pressure; 4) replace- Ductwork connections are made The direct spark ignition system able filter driers, which trap moisture easy by the logical 2 to 1 aspect ratio. saves operating expense when corn- and dirt; and 5) Carrier's exclusive On vertical discharge units, duct- pared to old-style pilot ignition systems Acutrol r" metering device, which pre- work attaches directly to the roof curb. No crossover tube is required, there- cisely controls refrigerant flow, pre- Accessory thru-the-curb service con- fore no sooting or pilot fouling venting slugging and floodback, while nections allow power, gas and control problems can occur.All ignition compo- maintaining optimum wiring to be routed through the curb, nents are contained in a compact unit performance. thereby minimizing roof penetrations. module that is easily accessible for ser- VarislideT" economizer permits low- Both power and control connec- vice Standard units are designed for cost operation by utilizing cool out- tions are made on the same side of the natural gas. An LP conversion kit door air for free cooling Reliable sliding unit to simplify installation. is available as an accessory, if required. plate damper is easily adjusted for The Drain Guard"" non-corrosive A solid-state control system is 100% outdoor air, 100% return air or condensate drain is factory installed and readily adaptable to all conventional any proportions of mixed air. Econ internally trapped. This eliminates and programmable thermostats In ad- omizer operation is controlled by the need for a field-supplied conden- dition, units are suitable for integra- Accusensor" I dry-bulb thermostat sate drain, saving time and money. tion into monitor control systems if which senses outdoor air temperature. Standard 2-in. throwaway type fil- required. Optional accessory upgrade kits in- ters are easily accessed through a Refrigerant circuit protection assures elude AccusensorT" II solid-state hinged access door located directly dependability All units have stan enthalpy control and Accusensor Ill above the air intake hood; no tools are dard: 1) loss-of-charge/low-pressure differential enthalpy control required to change the filters. Rounded corners on panels help to prevent Table of contents damage or puncture of roof materials. Weather-resistant cabinet is coated Page with a pre-painted enamel finish Model Number Nomenclature . . . . . 2 on all externally exposed surfaces to ARI Capacities 3 • ensure long life and attractive Physical Data 4, 5 appearance. Options and Accessories. . . 6, 7 Base Unit Dimensions . . . . . . 8,9 Quiet, efficient operation and Accessory Dimensions. . . . . . . . . . . . . . . . . 10,11 dependable performance Selection Procedure . . . . . 12 Compressors are fully hermetic with in- Performance Data 13-24 ternal vibration isolators for extremely Electrical Data. . . . . . . . . . . 25 quiet operation. Efficient condenser Typical Piping and Wiring . 26 fan and motor design permits opera- Application Data . 27 tion at a low sound power of 8.2 bels Typical Control Wiring Schematic 28,29 for sizes 004- 007, 8 6 bels for sizes Controls 29 008. 009 and 014 and 8.8 bels for size 012. Guide Specifications 30-35 All coils use state-of-the-art inter- nally enhanced copper tubing and are Model number nomenclature completely degreased before leav- ing the factory to eliminate coil blowoff problems. Condenser coils have louv- 48 DJ E 004 - 3 0 1 AA ered aluminum fins providing max- imum heat transfer for optimum Gas Heat efficiency DJ—Constant Volume FIOP Codo* Turbo-tubular" heat exchangers op- timize heat transfer for improved effi- D—Low Heat Packaging ciency. The tubular design permits E—High Heat hot gases to make multiple passes Series across the path of the supply air. In ad- Nominal Capacity dition, turbolators inside the heat ex- 004—3 Tons 008 — 71/2 Tons 1 —575-3-60 changer tube act as baffles, forcing 005—4 Tons 009 —81/2 Tons 3 —208/230.1-60 0 the hot gases to stay in close contact 006—5 Tons 012 —10 Tons 5 —208/230-3-60 with the cell walls and improving heat 007—6 Tons 014 —121/2Tons 6—460-3-60 transfer. i_ *Refer to 48DJ price pages for FIOP (Factory-Installed Options) code table. O 2 ARI* capacities NET COOLING SEER UNIT MODEL NOMINAL STANDARD CAPACITY(Btuh) TOTAL t SOUND 48 TONS CFM Single-Phase Three-Phase kW With Without EER RATING Units Units Timer" Timer (Bela) III DJE004 3 1200 34,800 34,600 4.1 9 7 9 5 8 4 8 2 DJD/DJE005 4 1600 48,000 48,000 5.8 9 3 9 1 8 3 8 2 DJD/DJE006 5 2000 60,000 59,500 7.0 9.5 9 3 8.6 8.2 NET UNIT MODEL NOMINAL STANDARD COOLING TOTAL SOUND RATING 48 TONS CFM CAPACITY kW EER (Bela) IPLV (Btuh) DJD/DJE007 6 2400 71,000 845 8.4 - 8.2 - tt DJD/DJE008 71/2 3200 89,000 10 4 8.5 8.6 tt DJD/DJE009 81/2 3400 100,000 11 2 8 9 8.6 tt DJD/DJE012 10 4000 118,000 13 7 8 6 8.8 tt DJD014 121/2 5000 144,000 17.5 8.2 8.6 7 9 LEGEND Rated in accordance with ARI Standards 210/240-89 or 360-86 (014 units) and 270-84 Bels — Sound Levels (1 bel = 10 decibels) EER — Energy Efficiency Ratio "°b•.. IPLV — Integrated Part-Load rgy Eff OD SEER — Seasonal Energy Efficiency Ratio i c2. ,, 'Air-Conditioning & Refrigeration institute. � tApplies only to units with capacity of 65,000 Btuh or less. Ratings are net values,reflecting the effects of circulating fan heat Rat- ' SEER ratings with timer are made using time delay relay part number ings are based on: HN67SK031. Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature tt-The IPLV is not required by certification agencies for 10-ton or smaller and 95 F db air entering outdoor unit units. IIIHEATING CAPACITIES AND EFFICIENCIES UNIT OUTPUT CALIFORNIA HEATING INPUT TEMPERATURE AFUE STEADY STATE MODEL (Btuh) CAPACITY RISE(°F) (%) EFFICIENCY(%) SEASONAL 48 (Btuh) EFFICIENCY(/o) DJE004 74,000 58,460 25-55 76 80 73 3 DJD005 74,000 58,460 25-55 76 80 73 3 DJE005 115,000 90,850 35-65 76 80 741 DJD006 74,000 58,460 25-55 76 80 73 3 DJE006 115,000 90,850 35-65 76 80 741 DJD007 74,000 58,460 25-55 76 80 73 3 DJE007 115,000 90,850 35-65 76 80 741 UNIT HEATING INPUT OUTPUT CAPACITY TEMPERATURE AFUE STEADY STATE CALIFORNIA SEASONAL MODEL (Btuh) (Btuh) RISE(°F) (%) EFFICIENCY(%) EFFICIENCY(%) 48 First Stage/Second Stage First Stage/Second Stage DJD008 120,000 96,000 20-50 78 5 80 75.3 DJE008 120,000/180,000 94,800/142,200 35-65 78 5 80 76.5 DJD009 120,000 96,000 20-50 78 5 80 75 3 DJE009 120,000/180,000 94,800/142,200 35-65 78 5 80 76 5 DJD012 120,000/180,000 94,800/142,200 35-65 78 5 80 76 5 DJE012 180,000/220,000 142,200/173,800 35-65 78 5 80 76 3 DJD014 180,000/220,000 142,200/173,800 35-65 78 5 80 76 3 LEGEND AFUE — Annual Fuel Utilization Efficiency co . NOTE NO„ Levels are 40 nanogramsfjoule with accessory kit. C 4i 3 - — Physical data BASE UNIT 48 DJE004 DJD/DJE005 DJD/DJE006 DJD/DJE007 NOMINAL CAPACITY 3 4 5 6 OPERATING WEIGHT(lb) Unit 530 540 560 615 • With Economizer 564 574 594 649 Roof Curb 115 115 115 115 COMPRESSOR Hermetic Quantity 1 1 1 1 Oil(oz) 55 55 70 70 REFRIGERANT TYPE -22 Operating Charge(lb-oz) 3-13 I 5.8 I 6.11 I 9-0 CONDENSER FAN Propeller Quantity...Diameter(in.) 1...28 1 .26 1..26 1 26 Nominal Cfm 3500 4100 4100 3800 Motor Hp...Rpm 1/3. 850 'h 850 1/3 850 1/3 850 CONDENSER COIL Enhanced Copper Tubes,Aluminum Lanced Fin Rows...Fins/In. 1...17 1 .17 1...17 2..17 Total Face.Area(sq ft) 7.78 12 25 12.25 12 25 EVAPORATOR FAN Centrifugal Size(in.) 10x10 10x10 10x10 10 x 10 Type Drive Std Direct Direct Direct Belt Alt Direct Belt Belt Belt Nominal Cfm 1200 1600 2000 2400 Horsepower per National Std 1/3 1/2 3/4 1 0 Electrical Code(NEC)* Alt 9.2 3/4 1.0 1.5 Maximum Continuous Bhp Std 3e 87 1 29 1 70 Alt 78 1.30 1.70 2.40 Motor Frame Std 48 48 48 56 Alt 48 56 56 56 Nominal Rpm High/Low Std 860/845 1080/970 1080/1040 — Alt 1080/970 — — — Fan Rpm Range Std — — — 875-1190 Alt — 800-1130 875-1190 1070-1460 Motor Bearing Type Ball Ball Ball Ball Maximum Fan Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Std — — — 2.8-3.8 A/B(In.) Alt — 2 4.3 4 2 8-3 8 2.8-3.8 Fan Pulley Pitch Diameter(In.) Std — — — 5 5 Alt — 52 55 45 Belt—Type...Length(In.) Std — — — A 40 Alt — A 40 A 40 A..39 Pulley Center Line Distance(in.) Std — — — 14 7-15.5 Alt — 14 7-15.5 14 7-15.5 14 7-15 5 Speed Change Per Full Turn of Std — — — 63 Movable Pulley Flange(rpm) Alt — 66 63 79 Movable Pulley Maximum Full Std — — — 5 Turns from Closed PosItion Alt — 5 5 5 Factory Setting—Full Turns Open Std — — — 3 Alt — 3 3 3 Factory Speed Setting(rpm) Std — — — 1000 Alt — 930 1000 1230 Fan Shaft Diameter at Pulley(in.) '/9 we 4'e EVAPORATOR COIL - Enhanced Copper Tubes,Aluminum Double Wavy Fin Rows...Fins/in. 2. 15 2...15 3..15 4..15 Total Face Area(sq ft) 4 17 5.5 5 5 5 5 FURNACE SECTION Burner Orifice Diameter(In. _drill size)t Natural Gas —Std 113...33 .113 33 113...33 113..33 Liquid Propane— Alt 089..43 089 43 089..43 089 43 Thermostat Heat Anticipator Setting(amps) 208/230/460 v 1.0 1 0 1 0 1 0 Gas Input 74,000 74,000/115,000 74,000/115,000 74,000/115,000 Efficiency(Steady State)(%) 80 80 80 80 Temperature Rise Range 25-55 25-55/35-65 25-55/35-65 25-55/35-65 Manifold Pressure(in.wg) Natural Gas— Std 3 5 3 5 3.5 3 5 Liquid Propane—Alt 3.5 3.5 3.5 3.5 Maximum Static Pressure(In.wg) 75 75 75 75 Field Gas Connection Size(In.) 5 : 5 5 5 HIGH-PRESSURE SWITCH(psig) Cutout 428 Reset(Auto.) 320 LOSS-OF-CHARGE/LOW-PRESSURE SWITCH (Liquid Line)(psig) Cutout 7 ± 3 Reset(Auto.) 22 ± 5 OUTSIDE-AIR INLET SCREENS Cleanable Quantity...Size(In.) 1...20 x 24 x 1 RETURN-AIR FILTERS Disposable Quantity...Size(in.) 2 16 x 25 x 2 LEGEND Bhp—Brake Horsepower 'Used to determine wire sizing per NEC t48DJD005-007 and 48DJE004(74,000 Btuh)units have 2 burners 480JE005-007(115,000 Btuh)units have 3 burners. ii 4 BASE UNIT 48 DJD/DJE008 DJD/DJE009 DJD/DJE012 DJDO14 NOMINAL CAPACITY(tons) 7'/2 81/2 10 121/2 OPERATING WEIGHT(lb) Unit 870 880 I 1035 I 1050 With Economizer 914 924 1079 L 1094 Roof Curb 143 143 143 143 COMPRESSOR Hermetic Quantity 2 2 2 2 Oil(oz)(each compr) 55 55 70 70 REFRIGERANT TYPE R-22 Operating Charge(lb-oz) Circuit 1 4-5 6-2 1 I 8-0 B- 3 Circuit 2 4.5 5-5 7-3 6-11 CONDENSER FAN Propeller Quantity...Diameter(in.) 1 .26 1.26 1..26 1 .26 Nominal Cfm 6500 6500 7000 8200 Motor Hp...Rpm 3/4 1100 3 1100 3 1100 l 3/4 1100 CONDENSER COIL Enhanced Copper Tubes,Aluminum Lanced Fins Rows...Fins/In. 1 ..17 2..17 2..17 2...17 Total Face Area(sq ft) 18 0 15 5 18 9 25 0 EVAPORATOR FAN Centrfugal Size(In.) 15 x 15 15 x 15 15 x 15 15 x 15 Type Drive Std Belt Belt Belt Belt Alt Belt Belt Belt — Nominal Cfm 3000 3400 4000 5000 Horsepower per NEC' Std 1 5 1 5 1 5 3 5 Alt 1 5 1 5 2 0 — Maximum Continuous Bhp Std 2 4 2 4 2 4 4 2 Alt 24 24 29 — Motor Frame Std 56 56 56 56 Alt 56 56 56 — Fan Rpm Range Std 600-800 600-800 700- 950 860-1080 Alt 700-900 700-900 850-1100 — Motor Bearing Type Ball Ball Bell Ball Maximum Fan Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Std 2 4-3 4 2 4-3 4 2 8-3 8 4 0-5 0 A/B(In.) Alt 2.8-3 8 2 8.3 8 3 4-4 4 — Fan Pulley Pitch Diameter(In.) Std 7 0 7 0 7 0 8 0 Alt 70 70 70 — Belt —Type...Length(in.) Std A 48 A 48 A 51 A 57 Alt A..48 A..48 A..51 — Pulley Center Line Distance(In.) Std 16 75-19 25 16 75-19 25 18 25-20 75 18 25-20 75 Alt 16 75-19.25 16 75.19 25 18 25-20 75 — Speed Change per Full Turn of Std 40 40 50 44 • Movable Pulley Flange(rpm) Alt 40 40 50 — Movable Pulley Maximum Full Std 5 5 5 5 Turns from Closed Position Alt 5 5 5 — Factory Setting —Full Turns Open Std 5 5 5 5 Alt 5 5 5 — Factory Speed Setting(rpm) Std 600 600 700 860 Alt 700 700 850 — Fan Shaft Diameter at Pulley(in.) 1 1 1 1 EVAPORATOR COIL =nhanced Copper Tubes,Aluminum Double Wavy Fins Rows...Fins/in. 3..15 3..15 3...15 4 15 Total Face Area(sq ft) 8 0 8 0 10 0 11 1 FURNACE SECTION Burner Orifice Diameter(in....drill size) Natural Gas— Std 120 31/120 31 120 31/120 31 120 31/120 31 .120 31 Liquid Propane— Alt .096 41/096 41 096 41/096 41 096 41/096 41 096 41 Thermostat Meat Anticipator Setting(amps) 208/230/460-v Stage 1 1 0 1 0 1 0 1 0 Stage 2 0 6 0 6 0 6 0 6 Gas input 120,000/120,000-180.000 120,000/120,000-180,000 120,000-180,000/180,000-220,000 180,000-220,000 Efficiency(Steady State)(%) 80 80 80 80 Temperature Rise Range 20-50/35-65 20-50/35-65 20-50/35-65 20-50 Manifold Pressure(In.wg) Natural Gas—Std 3 5 3 5 3 5 3 5 Liquid Propane— Alt 3 5 3 5 3 5 3.5 Maximum Static Pressure(In.wg) 1 0 1 0 1 0 1.0 Field Gas Connection Size(In.) 5/75 5/75 75/75 75 HIGH-PRESSURE SWITCH(psig) Cutout 428 Reset(Auto.) 320 LOSS-OF-CHARGE/LOW-PRESSURE SWITCH (Liquid Line)(psig) Cutout 7 ± 3 Reset(Auto.) 22 ± 7 OUTSIDE-AIR INLET SCREENS Cleanable Quantity...Size(In.) 1 20 x 25 1 16x25 RETURN-AIR FILTERS Disposable Quantlty...Size(in.) 4 16x20x2 I 4 16x20x2 i 4..20x20x2 14 20x20x2 LEGEND Bhp—Brake Horsepower 0 'Used to determine wire sizing per NEC. 5