Loading...
Permit � _ . „ CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT '�'-!° r COMMUNITY DEVELOPMENT Permit#: FPS2014-00160• TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/21/2014 Parcel: 1 S126BC01506 Jurisdiction: TIGARD Site address: 9020 SW WASHINGTON SQUARE RD 170 Project: Pioneer Design Group Subdivision: 2005-035 PARTITION PLAT Lot: 3 Project Description: Fire sprinklers,add(7)heads,relocate(3)heads and plug(2)heads. Contractor: AFP SYSTEMS INC Owner: WISCO REAL ESTATE EQUITY FUND I 19435 SW 129TH AVE 1501 SW TAYLOR ST STE 100 TUALATIN, OR 97062 PORTLAND, OR 97205 PHONE: 503-692-9284 PHONE: FAX: 503-692-1186 FEES Description Date Amount Specifics: Permit Fee-COM 10/21/2014 $80.68 12%State Surcharge-Building 10/21/2014 $9 68 Type of Use: COM Plan Review-Fire Life Safety-COM 10/21/2014 $32.27 Class of Work: ALT Type of Const: IIB Info Process/Archiving-Sm$0.50(up to 10/21/2014 $5.00 Occupancy Grp: B Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: Hazard: LT Density: 0 Design Area: 1500 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: • Battery Calcs Provided: Cut Sheets Required: Total $127.63 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $1,600.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 • This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. . may obtain a copy of the rules or direc estions . •UNC by�calling 503.232.1987 or 1.800.332.2344. I 11110 Issue By: t 4 / I Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Applica r Fire Protection System ') :FOR.OHHI( :t,I ON L-1 City of Tigard Received 4/_ UPI `' g 6 2 Q i Dateray: I1/ (p I y Penult No,:�i05 OC/ ° 13125 SW Hall Blvd.,Tigard,OR 972 Plan Review '�/ p �[ / a Phone: 503.718.2439 Fax: 503. •r.t, Date/By: '" v`a, [ 1"�.Other Permit: At/Vey/'DODO 7 ti G,s R D Inspection Line: 503.639.4175 I. IIGAHD Date Ready/By: / �/ orris; 0 See Page L for Internet: www.tigard-or.gov BUIp DIN nfinRIOV Notified/Meth..' (#g/7 Air lJ LI.pIIV@ i'�t Ll �+ Supplemental Information I /) .. ,....r,..•.. - . ........... .. :. :v,::. .. .%�;':. .;,.;TYPE,.-UF.�'W ` - ,::,REQUIREDDATA:�f;=AND;2;IcAMILY+•DWELLING:`'.:. ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(romded to the nearest dollar)of all ®Addition/alteration/replacement Cl Other: equipment,materials,labor,overhead,and the profit for the 'CATEGORY;OF.CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling Q Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION:='AND.IsOGATIO ::,.--: :; :,:r ':: ::`, ".. :: Total number of ours: Job site address: 't 0 2_0 St) ti)6Lsu.2a �t New dwelling area: square feet City/State/ZIP: Tine p 'L 9iZZi Garage/carport area: square feet Suite/bldg./apt.no.: ) Project name: pi gtr Covered porch area square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED. __ ,. Subdivision: 1 Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(romded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the .: .:DESCRIPTION OF WORK`:,.,r..-.- work indicated on this application. G-i , -4 6.(6.e.,-,215 , V'2-.F,(AL S e- S Larz kJ. Valuation: $ ` t L2• O "/ Pa ki...a. Existing building area square feet New building area: square feet : PROPERTY OWNER-'` :`.:; i ;; r:.."::..` : v=;:❑:TENANT:- .':;.`.: - Number Number of stories: Name: Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New IJ APPLICANT ':'•:,°;;':.: 0„CONTACT PERSON.:;;'.:,:',;;, : ::`. :' i', NOTICE.: : Business name: Ac-Pb„(S el el,„, • . All contractors and subcontractors are required to be Contact name: 5t .' CIS-tint two licensed with the Oregon Construction Contractors Board - -- - - under ORS 701 and may be required to be lensed in the Address: - tet LA, C, St4_5 v2-Pt s- Ab,e jurisdiction in which work is being performed.If the City/State/ZIP: �^ p 4:41-10(62_ applicant is exempt from licensing,the following reasons ( �1,k apply: Phone:(6o3 ) 624i/. '. ) ( Fax::(40 ) f$dl'L' (.1• ‘0 E-mail: 5 4.-_....;- , at-4.. Sy$ .C¢at-'1 Business name: 6 _ ci..� aja3Up_� (Please.refer tof esche le) Address: Permit fee: City/State/ZIP: State surcharge(12%of permit fee): Phone:( ) Fax: FLS plan review(40%ofpermit fee): ( ) (Due upon application.) CCB lic.: 6,'75j?je--/ Total permit fees: / Z7, (e-• Authorized signature C.7 �/ ” Amount received: f This permit application expires if a permit is not obtained Print name: auLs, Date: 1p,(9 (i within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. 1:18uilding\Pertnits\FPS-PermitApp.doc Rev 01/05/2012 440-0613T(1 I/02/COM/WE8) S • tIjCO Worldwide www.tyco-fire.com Fire Protection Contacts Products Series TY-B, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General NOTICE The Series TY-B Sprinklers described . Description herein must be installed and maintained . -3 r in compliance with this document, as The TYCO Series TY-B, 5.6 K-factor, well as with the applicable standards -- -, Upright (TY315) and Pendent(TY325) of the National Fire Protection Associa- *-' -.__,-7 ," Sprinklers described in this data sheet tion, in addition to the standards of any f F * j ; 4 itaa . are standard response,standard cover- other authorities having jurisdiction. age, decorative 5 mm glass bulb type Failure to do so may impair the perfor- E spray sprinklers designed for use in mance of these devices. . light, ordinary, or extra hazard, corn- 1----4-- mercial occupancies such as banks, The owner is responsible for maintain- --` I ^'hotels, shopping malls, factories, in g their fire protection system and - ,1 " refineries, and chemical plants. devices in proper operating condition. The installing contractor or sprinkler The recessed version of the Series manufacturer should be contacted with TY-B Pendent Sprinkler, where appli- any questions. cable,is intended for use in areas with a finished ceiling.This recessed pendent —s pr�nkler sprinkler uses one of the following: • A two-piece Style 15 Recessed ,� Escutcheon with recessed adjust- Identification WV, _ F ment up to 5/8 inch (15,9 mm) from Numbers (SINs) �` -,e,‘;:.,,, *,r the flush pendent position. -. -.-,� "' • A two-piece Style 20 Recessed TY315 Upright 5.6K, 1/2"NPT Escutcheon with recessed adjust- TY325 Pendent 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm) from _ .Y-1` the flush pendent position. Technical The adjustment provided by the Temperature Ratings Recessed Escutcheon reduces the Data 135°F(57°C) accuracy to which the fixed pipe drops 155°F(68°C) to the sprinklers must be cut. Approvals 175°F(79°C) UL and C-UL Listed 200°F(93°C) Intermediate level versions of Series FM, LPCB,and VdS Approved 286°F(141°C) TY-B Sprinklers are described in CE Certified 360°F(182°C)t Technical Data Sheet TFP352.Sprinkler guards and shields are described in Sprinklers with Polyester Finish are t UL,C-UL,and VdS Approved only Technical Data Sheet TFP780. UL and C-UL Listed as Corrosion- Resistant Sprinklers. Finishes Sprinkler: Refer to Table A Maximum Working Pressure Recessed Escutcheon:White Coated, 175 psi(12.1 bar) Chrome Plated,or Brass Plated 250 psi(17.2 bar)* *The maximum working pressure of 250 psi Physical Characteristics (17.2 bar)only applies to the listing by Un- Frame Bronze IMPORTANT derwriters Laboratories,Inc.(UL). Button Brass/Copper Always refer to Technical Data Sealing Assembly Stainless Sheet TFP700 for the "INSTALLER Discharge Coefficient Steel w/TEFLON WARNING" that provides cau- K=5.6 GPM/psi��2(80,6 LPM/bar��2) Bulb Glass tions with respect to handling and Compression Screw Bronze installation of sprinkler systems and Deflector Bronze components. Improper handling and . installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP152 TFP152 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* cr, i .6711E „ \\' /Trim i_141\N. } .---- --- / 5 yin 7/16" . (11,1 mm) — — } 111fc 4 NOMINAL fill 2" U �I MAKE-IN (50,8 mm) 2 �- 1-3/8" �� 3 L W i (50,82 2„mm) (34,9 mm) I `_, F WFLATSH 1 / — 1 f 1/2" NPT** DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE L, Operation Installation WRENCH RECESS ,..../... The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor, expands when exposed to heat. When Upright(TY315) and Pendent (TY325) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss of ' SPRINKLER WRENCH Design liquid from the bulb. With the sprinkler held horizontally, a small air bubble WRENCH Criteria should be present.The diameter of the RECESS The TYCO Series TY-B, 5.6 K-factor, air bubble is approximately 1/16 inch Upright TY315 and Pendent(TY325) inch (2,4 for the for t 135°F (57 C) to 3/32 ( ) ( ) inch (2,4 mm) for the 360°F (182°C) ��1 Sprinklers are intended for fire protec- temperature ratings. / tion systems designed in accordance with the standard installation rules A leak-tight 1/2 inch NPT sprinkler recognized by the applicable Listing joint should be obtained by applying a or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14 All is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels 4..., 13, and FM Approval is based on the of torque may distort the sprinkler inlet PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the IN TO ENSURE tion Data Sheets). Only the Style 15 sprinkler. ENGAGEMENT or Style 20 Recessed Escutcheon, as Do not attempt to compensate for WITH SPRINKLER applicable, is to be used for recessed insufficient adjustment in the escutch- WRENCHING AREA pendent installations. eon plate by under-or over-tightening FIGURE 3 the sprinkler. Readjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- I. tighten the sprinkler into the sprinkler fitting. i. TFP152 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 2-7/8" DIA. - 6 Sprinkler Wrench (Figure 2). With I (73,0 mm) reference to Figure 1, apply the W-Type 2-1/4" DIA. 6 Sprinkler Wrench to the wrench flats. FACE OF (57,2 mm) Torque sprinklers 7 to 14 ft.-Ibs. (9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers \ No FLUSH The Series TY-B Recessed Pendent 3/8±5/16" —1 I I I Sprinklers must be installed in accor- (9,5±7,9 mm) AN" % r % + t dance with the following instructions. } / Step A.After installing the Style 15 or MOUNTING ` ' 1/8" Style 20 Mounting Plate,as applicable, SURFACE (3,2 mm) over the sprinkler threads and with pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) threads, hand-tighten the sprinkler into TY-B PLATE the sprinkler fitting. 3/4"(19,1 mm) Step B. Tighten the sprinkler into the FIGURE 4 sprinkler fitting using only the W-Type SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) • 7 Recessed Sprinkler Wrench ( -Type WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. - sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After the ceiling is installed or SPRINKLER _ 2-1/4" DIA. - the finish coat is applied, slide on the FITTING (57,2 mm) Style 15 or Style 20 Closure over the 5/16±1/4" 12,7 mm Series TY-B Sprinkler and push the (7,9±6,4 mm) 1/2"( ) Closure over the Mounting Plate until + - FLUSH its flange contacts the ceiling. _ 27Z_Care and f I _&,,,,�0 1/8" Maintenance SOURFACE (3,2 mm) The TYCO Series TY-B, 5.6 K-factor, –" Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-B PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) main control valve for maintenance WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. The owner is responsible for the system from the proper authorities Sprinklers that have been exposed to inspection,testing,and maintenance of and notify all personnel who may be corrosive products of combustion, but their fire protection system and devices affected by this action. have not operated, should be replaced in compliance with this document, as Absence of the outer piece of an if they cannot be completely cleaned by well as with the applicable standards escutcheon, which is used to cover wiping the sprinkler with a cloth or by of the National Fire Protection Associa- a clearance hole, can delay sprinkler brushing it with a soft bristle brush. tion (e.g., NFPA 25), in addition to the operation in a fire situation. Care must be exercised to avoid dam standards of any other authorities hav age to the sprinklers - before, during, ing jurisdiction. Contact the installing The owner must assure that the and after installation. Sprinklers dam- contractor or sprinkler manufacturer sprinklers are not used for hanging regarding any questions. any objects and that the sprinklers are aged by dropping, striking, wrench only cleaned by means of gently dust- twist/slippage, or the like, must be Automatic sprinklers are recommended ing with a feather duster; otherwise, replaced. Also, replace any sprinkler to be inspected,tested,and maintained non-operation in the event of a fire or that has a cracked bulb or that has lost by a qualified Inspection Service in inadvertent operation may result. liquid from its bulb. (Ref. Installation accordance with local requirements Section.) and/or national codes. Sprinklers which are found to be leak- , ing or exhibiting visible signs of corro- Thereafter, annual inspections per sion must be replaced. NFPA 25 are required; however,instead of inspecting from the floor level, a Automatic sprinklers must never be random sampling of close-up visual painted, plated, coated, or otherwise inspections should be made. altered after leaving the factory. TFP152 -- - Page 4 of 4 P/N* 77 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 570 5.6K UPRIGHT(1/2"NPT) TY315 1 NATURAL BRASS 135 135°F(57°C) 571 5.6K PENDENT(1/2"NPT) TY325 3 PURE WHITE(RAL9010" 155 155°F(68°C) POLYESTER *Use suffix"I"for ISO 7-1 connection; SIGNAL WHITE(RAL9003) for example,77-570-4-175-I 4 POLYESTER 175 175°F(79°C) 9 CHROME PLATED 200 200°F(93°C) Eastern Hemisphere sales only 286 286°F(141°C) 360 360°F(182°C) 000 OPEN"' "'OPEN indicates sprinkler assembly without Glass Bulb, Button,and Sealing Assembly TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating,(specify)finish, P/N (specify, refer to Table A) Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N(specify*) Specify:Style 20 Recessed Escutcheon with(specify*)finish, P/N(specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. t o TEFLON is trademark of The DuPont Corporation. Fire Protection Products • >� NOTES ? A-TOTAL TO ADD 155 DEG. SR CHR PEND 2 R-TOTAL TO RELOCATE 155 DEG. SR CHR PEND . HEAD- 1/2 "TYCO K=5.6 155 DEG. SR CHROME PEND SEMI-REC ESC • ALL PIPE TAPPED W/MECH SADDLES o - -- - --- -� ALL PIPE SCH 40 ui I-3 ALL WORK PER N.F.P.A. &LOCAL AUTHORITY -I ______ji 2 - , ,Il ,, il ,_____, . I/ ' I I RECEIVED z o a E . I ' X X 4 + 4- ' :-; � ' OCT 62014 Q ¢ ¢ Oo �� as CITY OFTIGARD w w a 0 BUILDING DIVISION o w o f ♦ 10'-0" I N Ft IiIr4ii4 4- I W Il' N � , iii_ 1 - e . /� CITY OF'I'IGAI2I) ®um�TTc` FIRE PROTECTION RE VIEWED O F R CODE COMPLIANCE 111111.111111E11; I © SYSTEMS, INC. _, I 1 � Approved [�� 1 _ I�/. OTC: [ ] 8. r- ± ; 1 ( r I i � A - -- Permit#: l�—� ���� Address: ��)�Q �lcSlS�—F i 1 I T _ ! , Suite #: •s R r By: Date: 16• 16!33 39 Mb AVENUE �� - NAtANA OREGON I 'll 1 , OR CCS#0067534 . I Xf ♦ . — , , __- _ °!1 OFFICE COPY • I f ; , SIX FAN (503)682-11135 ' --� I h , T / _4P. .' -._..-- ----e_._ DRAWN BY: S.F. — �. I // - • .—. j CHECkED BY: O 1 ! I 1 I I DATE: 09/25/14 I i __-1 1 1 , —.-_ 1`i PROJECT AFP. PROJECT a J' '!Q TITLE: Fire Sprinkler Plan 9a REFLECTED CEILING PLAN %, , SCALE: 1/8"= 1'-0" - SHEET: FP-1 0 f 1 _j