Loading...
Report FIRE SPRINKLER o RECEIVED Cr 22014 Product Data and Calculations For: ��I T y0F O C©11v''+�y�,Slf��r TVF&R #51 8935 SW Burnham St. Tigard, OR 97223 City of Tigard PREPARED BY: Apw.yeq Plans B Date �6t14 Y _ E3U FIRE PROTECTION OFFICE COPY Viking Automatic Sprinkler Co. 3245 NW Front Avenue Portland, OR 97210 24 Hrs. 0: 503.22 7.1171 F: 503.227.1552 OR CCB #64837 • Metro Lic #2816 • WA LIC #VI-KI-NA-5373NT Boise • Longview • Medford • Portland • Seattle do PACE Submittal Date: September 24, 2014 Fs,; F y" ' OPP-oREG0 -31 N � 1M toux- /o 02/ 14 TABLE OF CONTENTS SECTION #1 — Sprinkler Heads A. Viking, Quick response, pendent, SIN VK302 B. Viking, Quick response, upright, SIN VK300 C. Viking, Standard response, dry HSW, VK 156 D. Vic Flex 48" SECTION#2— Hydraulic & Seismic Calculations A. City of Tigard Flow Test B. Hydraulic Calculations C. USGS Report D. Seismic Calculations December 4, 2013 Sprinkler 41a NIKING MICROFAST®AND TECHNICAL DATA MicrofastHP° QUICK RESPONSE PENDENT SPRINKLERS The Viking Telephone: 269-945-9501 Technical rSery Services: 877-384-5464 1 Fax: 269-818-1680 Ema l: techsvcs@vikingcorp.com DESCRIPTION @vlkingcorp.com Viking Microfastt and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes "�`�"—'- ±�� and temperature ratings and K-Factors to meet design requirements. The special Polyester,Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) — ■Ir` coatings can be used in decorative applications where colors are desired. In ad- dition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval • Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corrosion resist- ant.) 2. LISTINGS AND APPROVALS ' :41‘ eos cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2015, and 2017 NYC Approved:Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 PN 12979 PN 06666B ABS Certified: Certificate 04-HS407984C-PDA VdS Approved: Certificates G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. Nos. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificates of conformity 0786-CPD-40130, 0786-CPD-40170 and 0786-CPD- 40279, 0832-CPD-2001, and 0832-CPD-2003 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on page 41d for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria on page 41f for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for Viking Technical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar) up to 250 psi(17 bar)for high-pressure systems. High-pres- http:/Iwww.vikinggroupinc.com. sure (HP) sprinklers can be identified by locating "250" stamped on The Web site may include a more recent the deflector.All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar)wwp. edition of this Technical Data Page. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: Refer to the Approval Charts Nominal K-Factor Refer to the Approval Charts Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing. FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12979 and 12282. Brass UNS-C84400 for all other sprinklers. Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 for Sprinklers 12979, 06666B, and 06765B. Copper UNS- C19500 for Sprinkler 12282. Phosphor Bronze UNS-C51000, Copper UNS-C19500 or Brass UNS-C26000 for Sprinkler 067208. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed. Screw and Pipcap- ENT coated. Form No F_081296 Replaces page 41a-f, dated June 28, 2013. (Changed 06932B to VK3311.) Sprinkler 41b December 4, 2013 NIKING® MICROFAST®AND TECHNICAL DATA MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Ordering Information: (Also refer to the current Viking price list.) Order Microfast®and MicrofastHP®Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome= F, White Polyester= M-/W, Black Polyester = M-/B, Black PTFE = N, and ENT=JN Temperature Suffix: 135 °F (57 °C) =A, 155 °F (68°C) = B, 175 °F (79°C) = D, 200 °F (93 °C) = E, and 286 °F (141 °C) = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No 10896W/B (available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B*(available since 2011) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) *A'A"ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No 01724A(available since 1971) B. Twelve-head capacity: Part No 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance require- wrench ±_ ments. t Flat iNi�IN III iN,Q i Protective 7. AVAILABILITY Protective l'i�` ilSprinkler Sprinkler Cap The Viking Microfast®and MicrofastHP®Quick Response Pendent 10 I Shield Sprinklers are available through a network of domestic and 144,..„. international distributors. See The Viking Corporation web site for ,�j I I II, the closest distributor or contact The Viking Corporation. \ 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule 10896 or contact Viking directly. `I�• Figure 1: Standard Sprinkler Wrench 10896W/B December 4, 2013 Sprinkler 41c NIKINei. MICROFAST°AND TECHNICAL DATA MicrofastHP° QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification - 1,-1 _ . , .fig Temperature' Ordinary 135°F(57°C) 100 °F (38 °C) Orange Ordinary 155°F(68 °C) 100 °F (38 °C) Red Intermediate 175°F(79 °C) 150°F (65 °C) Yellow Intermediate 200°F(93 °C) 150 °F (65 °C) Green High 286°F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C). Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading.sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE. and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. 1 / 1 1 i a� AliFill A\ 11 iiitiniilt t= Sprinkler Wrench a'- - 16036W/Bo* for installing recessed r I 71.-71 pendent sprinklers I I.I j ,II h ■N■A 1/2 ratchet is required (not available From Viking). r -4 1 .� I I I I I Carefully slide the f 1 '===4° = J I I wrench sideways i 1 around the protective cap, ensuring engage- ment with the sprinkler wrench flats. Figure 2: Wrench 16036W1B for Recessed Pendent Sprinklers Sprinkler 41 d December 4, 2013 NitaNG A MICROFAST®AND TECHNICAL DATA MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 1 (UL) Temperature KEY Microfast®and MicrofastHP®Quick Response Pendent Sprinklers ' Finish At 4-Escutcheon(if applicable) Maximum 175 PSI (12 bar)WWP Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.' NPT BSP U.S. metric' Inches mm cULus4 NYC' VdS LPCB C E 0 Standard Orifice 12979 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 57 A1X,B1Y,C4,E4Z A1X,B1Y — — — - 18021 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 A1X,B1Y A1X,B1Y A2 A2X,B2Y • C2X,E2Y" C2X,E2Y14 Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 A1X,B1Y,C4,E4Z A1X,B1Y A2 A2X C2" -- 06765B15 VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 A1X,B1Y,C4,E4Z AIX,B1Y A2 -- • A212 -- Small Orifices 06718B' VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 A1X,B1Y AiX,B1Y -- -- -- -- 06720B4 VK331 112" 15 mm 4.2 57 2-1/4" 58 A1X,B1Y A1X,B1Y — — -- -- 06932B VK3311 — 10 mm 4.2 57 2-3/8" 60 -- -- A2 -- G3'' -- Maximum 250 PSI (17 bar)WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metric' Inches mm cULus' NYC10 VdS LPCB CE 0 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 A1X,B1Y A1X — -- -- -- Maximum 250 PSI(17 bar)WWP Small Orifice' 12290'° VK342 1/2" 15 mm 2.8 40.3 2-3/16" 56 A1X,B1Y A1X — -- -- -- Approved Temperature Ratings Approved Escutcheons A-135°F(57°C),155°F(68°C), 175°F(79°C),200°F(93°C),and Approved Finishes X - Standard surface-mounted escutcheon or 286°F(141 °C) 1 - Brass, Chrome, White Polyester", Black the Viking Microfast'" Model F-1 Adjustable B-135°F(57°C),155°F(68°C),175°F(79°C),and 200°F(93°C) Polyester67,and Black PTFE' Escutcheon C-155°F(68°C), 175°F(79°C),200°F(93°C),and 286°F(141 2-Brass, Chrome,White Polyester',and Black Y - Standard surface-mounted escutcheon or °C) Polyester' the Viking Microfast" Model F-1 Adjustable D-135°F(57°C), 155°F(68°C), 175°F(79°C),and 286°F(141 Escutcheon or recessed with the Viking °C) 3-Brass and Chrome Micromatic'Model E-1,E-2,or E-3 Recessed E-155°F(68°C),175°F(79°C),and 200°F(93°C) 4-ENT' Escutcheon F-155°F(68°C),175°F(79°C),and 286°F(141 °C) Z-Standard surface-mounted escutcheon or re- G-155°F(68°C) cessed with the Viking Micromatice Model E-1 Footnotes Base part number is shown For complete part number,refer to Viking's current price schedule 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals 4 Listed by Underwriters Laboratories Inc.for use in the U.S and Canada. 'Accepted for use,City of New York Board of Standards and Appeals,Calendar Number 219-76-SA. 6 cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 6 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet systems only. Exception:4 2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized 9 The sprinkler orifice is bushed. 1'Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol.16. 11 CE Certified,Standard EN 12259-1,EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. 12((Certified,Standard EN 12259-1,EC-certificate of conformity 0786-CPD-40279. "((Certified,Standard EN 12259-1,EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170 4 O MED Certified,Standard EN 12259-1,EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. i5 The 1/2"NPT Large Orifice Sprinkler is Listed and Approved for retrofit only. December 4, 2013 Sprinkler 41e NI KiNa, MICROFAST®AND TECHNICAL DATA MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1 on page 41d) cULus Listing Reauirements: Microfast®and MicrofastHP®Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies(exception:small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size, 2-5/16' (58.7 mm) minimum 2-1/8' 2-1/2' (63.5 rIm) maximum (54 rim) 1/2' ill] IN<LS nn) � 1RNE∎_�M■ NPT �‘ __- �� � I i ¶lz• I 2 1/4' ØJ 1-3/4' 1-5/8' 11111 (58 rom) (4 4.5 mm) 2' JiJ� 1 1/2' (38.1 7r1) (50.8 Mro) Minimum (41 '^^) �0 Maximum j Installed with a Pendent Sprinkler standard 1/8' surface- mounted escutcheon. Installed with a Microfast Model F-1 Adjustable Escutcheon s Note, At maximum, adapter is exposed 1/2' (12.7 mm) from face of ceiling. Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon 2-1/8' Ceiling Opening Size: 2-1/8• (54 rim) 2-5/16' (58.7 mm) minimum (54 mm) 2-1/2' (63.5 mm) maximum 1U iM■ : _ 111 irti i ... ' . _..: N Irail II ...,...7„.:::::::,::,,..... 1-3/4' 411 1-1/8' (28.6 trim) (44.5 mm) Minirnurn 2• 1_ (28.6 rnro) _ t (50.8 trim) S Miniyyrnum Maximum _ Maxirnurn 1 i Installed with a Micrornatic Model E-1 Recessed Escutcheon Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Sprinkler 41f December 4, 2013 NIKING MICROFAST®AND TECHNICAL DATA MicrofastHP° QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 2 (FM) r__ Temperature KEY Microfasr°'Quick Response Pendent Sprinklers I•f�Finish Maximum 175 PSI (12 bar)WWP A1xt Esculdreon tit applicable) Sprinkler pprovals SIN Thread Size Nominal K-Factor Overall Length FM A 3 Base Part No.' NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) Standard Orifice 12979 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 57 A2X, B2Y,C3, D3Z 18021 VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 A2X, B2Y Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 A2X, B2Y, C3, D3Z 06765B7 VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 A2X, B2Y,C3, D3Z Small Orifice' 0671886 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 A1X Approved Temperature Ratings Approved Escutcheons A-135°F(57°C), 155°F(68°C), 175°F(79°C), X-Standard surface-mounted escutcheon or the Viking 200°F(93°C),and 286°F(141 °C) Approved Finishes Microfast®Model F-1 Adjustable Escutcheon B- 135°F(57°C), 155°F(68°C), 175°F(79°C), 1 -Brass and Chrome Y - Standard surface-mounted escutcheon or the and 200°F(93°C) 2 - Brass, Chrome, White Polyesters, and Viking Microfast®Model F-1 Adjustable Escutcheon C-155°F(68°C), 175°F(79°C),200°F(93°C), Black Polyesters or recessed with the Viking Micromatic®Model E-1, and 286°F(141 °C) 3-ENT' E-2,or E-3 Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F Z-Standard surface mounted escutcheon or recessed (93°C) with the Viking Micromatic®Model E-1 Footnotes ' Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 'FM Approved as quick response control mode standard spray Non-storage sprinklers.For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). 'Other colors are available on request with the same Listings and Approvals as the standard colors. 6 The sprinkler orifice is bushed. 'The 1/2"NPT Large Orifice Sprinkler is Listed and Approved for retrofit only 8 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-storage standard spray pendent sprinklers as indicated in the FM Approval Guidet. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheets 2-0 and 8-9).FM Global Loss Prevention Data Sheets contain guidelines relating to,but not limited to:minimum water supply requirements, hydraulic design.ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. tSprinklers VK302 and VK352 are also FM Approved as quick response Rack Storage standard spray pendent sprinklers. Refer to technical data page 131a-e for Intermediate Level In-Rack Sprinklers. IMPORTANT:Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to page QR1-3 for gen- eral care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_081296 Replaces page 41a-f, dated June 28, 2013. (Changed 069328 to VK3311.) December 4, 2013 Sprinkler 51a MICROFAST®AND TECHNICAL DATA MicrofastHP° QUICK RESPONSE UPRIGHT AND The Viking CONVENTIONAL SPRINKLERS Telephone: 269-945-9501 Technical rSery ces: 877-384-5464' Fax: 269-818-6801 Email l: tech8 1. DESCRIPTION Svcs @vlkingcorp.com Viking Microfast°and MicrofastHP®Quick Response Upright and Conventional(Old Style)Sprinklers are small,thermosensitive,glass-bulb spray sprinklers available in several different finishes,temperature ratings,and K-Factors to meet design require- ments.The special Polyester,Polytetrafluoroethylene(PTFE),and Electroless Nickel PTFE(ENT)coatings can be used in decorative applications where colors are desired. In addition,these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM _ Global has no approval classification for PTFE and Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS - 0,,, cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984B-PDA VdS VdS Approved: Certificates G4060054, G4060056, G4880046, G4930039, and G4980020 e9r a LPC Approved: Ref. No. 096e/03, TE30401, and TE30872 c CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, 0786-CPD-40171, and 0786-CPD-40278 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on pages 51c-d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 51e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Viking Technical Data may be found on Available since 1987. The Viking Corporation's Web site at Minimum Operating Pressure: 7 psi (0.5 bar)* http://www.vikinggroupinc.com. Maximum Working Pressure: Sprinklers VK315 and VK340 are rated for The Web site may include a more recent use with water working pressures ranging from the minimum 7 psi(0.5 edition of this Technical Data Page. bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure (HP)sprinklers can be identified by locating "250"stamped on the de- flector.All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: Refer to the Approval Charts *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass for Sprinklers 12978, 06766B, 07060, and 12281. Brass UNS-C84400 for all other sprinklers. Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 12978, 06764B, and 12281. Copper UNS-C19500 for Sprinklers 066656, 07060, and 14817. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Form No. F_080488 Replaces page 51a-e, dated June 28, 2013. (Changed 06931 to VK3271) Sprinkler 51b b December 4, 2013 im N MICROFAST®AND TECHNICAL DATA MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap-ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Microfast®and MicrofastHP®Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass=A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, and Black PTFE = N, ENT= JN Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2"thread, Brass finish and a 155°F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No 10896W/B (available since 2000) Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection. Testing and Maintenance requirements. 7. AVAILABILITY The V king Microfast®and MicrofastHP®Quick Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F(68°C) 100 °F (38 °C) Red Intermediate 175°F(79 °C) 150 °F (65°C) Yellow Intermediate 200 °F(93 °C) 150 °F (65 °C) Green High 286°F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE. and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply.depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51c-e.These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment.For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers with Polyester, ENT,and PTFE coatings. For ENT coated automatic sprinklers,the waterway is coated. December 4, 2013 Sprinkler 51c NIIKING. MICROFAST®AND TECHNICAL DATA MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 1 (UL) Temperature KEY Microfast and MicrofastHPe Quick Response 4-- Flnish Upright and Conventional Sprinklers A1XF Escutcheon(if applicable) Maximum 175 PSI(12 bar)WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals' SIN (Refer also to Design Criteria on page 51d.) Number' NPT BSP U.S. metric' Inches I mm cULus* I NYC' VdS LPCB (E O Upright-Standard Orifice 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B4 See Footnote 7 -- -- -- - 07060 VK345 -- 15 mm _ 5.6 _ 80.6 2-3/16 56 -- -- A2 A2 8212 _ B2t5 Conventional-Standard Orifice 06766B VK310 1/2" 15 mm 5.6 I 80.6 I 2-3/16 I 56 A2 A2 -- ' A2 I B212 1 8215 Upright-Large Orifice 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 Al, B4 Al A2 A2 B212 -- 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, B4 Al A2 A2 8212 -- 06764B 6 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al, 64 Al A2 -- A2'3 -- Conventional-Large Orifice 06768B I VK354 3/4" 20 mm 8.0 115.2 2-5/16 59 Al A2 -- A2 B272 -- Upright-Small Orifice" 06717B" VK325 1/2" 15 mm 2.8 40.3 2-3/16 56 Al Al -- -- -- -- 06719B" VK327 1/2" 15 mm 4.2 57 2-3/16 56 Al Al -- -- -- -- 06931 B" VK3271 -- 10 mm 4.2 57 2-3/16 56 -- -- A2 -- C3" -- Maximum 250 PSI (17 bar)WWP Upright-Standard Orifice Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals' SIN (Refer also to Design Criteria on sage 51d.) Number' NPT BSP _ U.S. metric2 Inches mm cULus4 NYC' VdS LPCB (E 0 12281 VK315 1/2" 15 mm 5.6 _ 80.6 2-3/16 56 Al _ Al -- -- -- -- Upright-Small Orifice10 12286" VK340 1/2" 15 mm 2.8 40.3 I 2-3/16 56 I Al Al -- -- I -- -- Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 1 - Brass, Chrome, White Polyester", Black Polyester", and 286 °F(141°C) Black PTFES B- 155 °F(68 °C), 175°F (79°C), 200°F(93 °C), and 286°F (141°C) 2 - Brass, Chrome,White Polyester", and Black Polyester56 C 155°F(68°C) 3- Brass and Chrome 4- ENT5 Footnotes 'Base part number is shown.For complete part number,refer to Viking's current price schedule 2 Metnc K-factor measurement shown is when pressure is measured in Bar When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of panting.Check with the manufacturer for any additional approvals. °Listed by Underwriters Laboratories Inc.for use in the U.S and Canada s cULus Listed as corrosion resistant. 'Other colors are available on request with the same Listings and Approvals as the standard colors. 'Meets New York City requirements,effective July 1,2008. 'Accepted for use.City of New York Board of Standards and Appeals,Calendar Number 219-76-SA. 0 Accepted for use,City of New York Department of Buildings,MEA 89-92-E,Vol. 16. 10 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet systems only. Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. "The sprinkler orifice is bushed. '2 ((Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13 ((Certified,Standard EN 12259-1,EC-certificate of conformity 0786-CPD-40278. 1* ((Certified,Standard EN 12259-1,EC-certificate of conformity 0766-CPD-40131. 15 0 MED Certified,Standard EN 12259-1,EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. '6 The 1/2"NPT Large Orifice Sprinkler is Listed and Approved for retrofit only Sprinkler 51d December 4, 2013 N11(INGot MICROFAST®AND TECHNICAL DATA MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com DESIGN CRITERIA- UL (Also refer to Approval Chart 1 on page 51c) cULus Listina Reauirements; Microfast®and MicrofastHP®Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers,or old style(conventional)sprinklers. • Designed for use in Light and Ordinary Hazard occupancies (exception:small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers, refer to the installation guidelines for old style(conventional)sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Protective Wrench Sprinkler Flat �'i i-�=!, il/ Cap 10896 CD) i® Figure 1: Standard Sprinkler Wrench 10896W/B December 4, 2013 Sprinkler 51e N1KING. MICROFAST°AND TECHNICAL DATA MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 2 (FM) Temperature KEY Microfasr Quick Response Upright Sprinklers f� Escutcheon A1X4-Escutcheon(If applicable) Maximum 175 PSI (12 bar)WWP Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals' Number' NPT BSP U.S. metric2 Inches mm (Refer also to Design Criteria below.) Standard Orifice 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 A2, B3 07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 A2 Large Orifice 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 A2, B3 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 A2, B3 • 06764B' VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 A2, B3 Small Orifice' 06717B6 VK325 1/2" 15 mm 2.8 40.3 2-3/16 56 Al Approved Finishes Approved Temperature Ratings 1 - Brass and Chrome A- 135°F (57°C), 155°F(68 °C), 175°F(79°C), 200°F(93°C), and 286 °F (141°C) 2 - Brass, Chrome, White Polyesters, and Black B- 155 °F(68°C), 175°F(79°C), 200 °F(93°C), and 286°F(141°C) Polyesters 3-ENT8 Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 'Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing.Check with the manufacturer for any additional approvals. ° FM Approved as quick response Non-Storage pendent sprinklers. For specific application and installation requirements, reference the latest appli- cable FM Loss Prevention Data Sheets(including Data Sheet 2-0). Other colors are available on request with the same Approvals as the standard colors. 6 The sprinkler orifice is bushed. The 1/2"NPT Large Orifice Sprinkler is Listed and Approved for retrofit only h FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Aooroval Reauirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-Storage upright sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to,but not limited to:minimum water supply requirements.hydraulic design,ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes, ordinances, and standards,whenever applicable. THIS PAGE INTENTIONALLY LEFT BLANK Form No F_080488 Replaces page 51a-e, dated June 28, 2013. (Changed 06931 to VK3271) February 26, 2014 Sprinkler 102a NIKING® STANDARD RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com 1. DESCRIPTION Viking Standard Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the supply nipple before sprinkler operation. ;I They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Standard Response Dry Horizontal Sidewall Sprinklers are available in - -- - various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) N 1)11 111.1i OTE: When installed in some corrosive environments, the Polyester finish 'I may change color.This natural discoloration over time is not in itself an indi- cation of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. For Light Hazard Occupancies Only 2. LISTINGS AND APPROVALS ut „s cULus Listed: Category VNIV <`■> FM Approved: Class 2013 and 2015 NYC Approved: MEA 89-92-E, Volume 2 Refer to Approval Chart 1 and Design Criteria on page 102d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 102e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1991. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. *Metric K-factor measurement shown is when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F (-55 °C) Material Standards: tr.` Frame Casting: Brass UNS-C84400 :• Deflector: Phosphor Bronze UNS-C51000 Bulb: Glass, nominal 5 mm diameter w , Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600 The Viking Corporation's Web site at Pip Cap Adapter: Brass UNS-C36000 http://www.vikinggroupinc.com. Orifice: Copper UNS-C22000 or UNS-C11000 The Web site may include a more recent Tube: ERW Hydraulic Steel Tube edition of this Technical Data Page. Inlet and Barrel Threads: QM Brass Support(Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Form No. F_073091 Replaces page 102a-i, dated July 17, 2013. (Removed Seal Part Number) Sprinkler 102b February 26, 2014 NIKING* STANDARD RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Order Standard Response Dry Horizontal Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish, the ap- propriate suffix for the temperature rating, and then the suffix for the length ("A" dimension)to sprinkler base part number. Order in a specific length noted as the"A"dimension (see Figures 2. 4, and 6). The"A"dimension is the distance from the face of the fitting (tee) to the desired finished surface of the wall in which it is to be installed. These sprinklers are listed and approved in lengths from 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) for the adjustable standard style, 3"to 47" (76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4"to 47-1/2" (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a "made-to-order" basis: Recessed Dry Horizontal Sidewall up to 65-1/4" (1,664 mm). Adjustable Standard Dry Horizontal Sidewall up to 63-1/2" (1,613 mm). Plain Barrel Dry Horizontal Sidewall up to 65" (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, and ENT=JN Temperature Suffix (°F/°C): 155°/68° = B, 175°/79°= D, 200°/93° = E, 286°/141° = G Escutcheon Suffix = Y for the adjustable recessed sprinkler with the Model G-1 Escutcheon (no suffix needed for the Model E-1 Escutcheon). For example, sprinkler VK162 with 1" NPT Threads, a Chrome finish, a 155 °F/68°C temperature rating, a Model G-1 Escutcheon, and "A" length of 10" = Part No. 07856UFBY10. Available Finishes And Temperature Ratings: Refer to Table 1. NOTE: Sprinkler is turned sideways for clarity. (Refer to Figures 2-7 Accessories: (Also refer to the "Sprinkler Accessories" section of the for correct deflector orientation.) Viking data book.) Protective Sprinkler Wrenches: sprinkler A. Standard Wrench: Part No. 07297W/B (available since 1991) Shield B. Recessed Sprinkler Wrench: Part No. 07565W/B** (available since "1 ' • irk- 1991) **A'A"ratchet is required(not available from Viking). 1I �.� Dry Sprinkler Protective Cover: Part No. 15610 di ■ Replacement Escutcheons: 'n A.Adjustable Standard Dry Escutcheon: Base Part No. 08086F Wrench B. Model E-1 Recessed Dry Escutcheon Cup: Base Part No 05459A Flat 4. INSTALLATION Refer to appropriate NFPA Installation Standards. VIKING °,"„ O�) 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, Figure 1: causing the glass to shatter, releasing the internal parts to open the water Standard Sprinkler Wrench 07297W/B way. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Standard Response Dry Horizontal Sidewall Sprinkler is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. February 26, 2014 Sprinker 102c NIKING. STANDARD RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Classification Maximum Ambient Temperature Rating' Ceiling Temperature Bulb Color Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F(79°C) 150 °F (65 °C) Yellow Intermediate 200°F(93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating', : White Polyester and ENT in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof. Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 'When installed in some corrosive environments,the Polyester finish may change color.This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. Step 2: Press the wrench onto /l the sprinkler wrench flats and /l V turn slightly to ensure engage— '1/` Sprinkler Wrench Part dent with the wrench flats. No, 07565W/Bmm for installing recessed dry sprinklers. NO A 1/2' ratchet is required. (Not available from Viking,) •-----__ is 1 ---_i .--------, `----t 1. 1 I i I.,C :.,.. , 1i' -.Vi=m iN s l ------------ 1 Step 1: Carefully slide the Note: The Model E-1 Escutcheon wrench sideways around the is shown. Installation is similar deflector and protective shield as shown, with the Model G-1 Escutcheon. Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Horizontal Sidewall Sprinklers Sprinkler 102d February 26, 2014 R: STANDARD RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com Approval Chart 1 (UL) Temperature KEY Standard Response Dry Horizontal Sidewall Sprinklers Finish AIX4--Escutcheon(if applicable) Maximum 175 PSI(12 bar)WWP Sprinkler Thread Size Nominal K-Factor2 Order Length Listings and Approvals° Base Part SIN Style _ Increment (Refer also to Design Criteria below.) Number' NPT BSP U.S. metric' Inches mm cULuss NYC6 VdS LPCB (E p 07857U Adjustable 1" -- 5.6 80.6 1/2" 12.7 A1,A5 Al -- -- -- -- VK156 Standard --07860U 25 mm 5.6 80.6 1/2" 12.7 Al,A5 -- 07856U Adjustable 1" -- 5.6 80.6 1/4" 6.35 B2, B6 B2 -- -- -- -- VK162 Recessed --07859U 25 mm 5.6 80.6 1/4" 6.35 B2, B6 -- 07858U Plain 1" -- 5.6 80.6 1/2" 12.7 A3 A4 -- -- -- VK152 Barrel 07861U 25 mm 5.6 80.6 1/2" 12.7 A3 -- -- -- -- -- Approved Finishes and"A"Dimensions 1 -Chrome, Brass, or White Polyester' sprinkler with a Chrome, Brass, or White Polyester Sleeve and Approved Temperature Ratings Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) A- 155°F (68°C), 175 °F(79°C), 200 °F (93 2-Chrome,Brass,or White Polyester'with"A"dimensions 3-1/4"to 47-1/2"(82.5 to 1,207 mm) °C),and 286°F(141 °C) 3-Chrome,Brass,White Polyester',or ENT'with"A"dimensions 3"to 47"(76.2 to 1,194 mm) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F 4-Chrome or Brass with"A"dimensions 3"to 47"(76.2 to 1,194 mm) (93°C) 5- ENT'sprinkler with an ENT'Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) 6-ENT'with"A"dimensions 3-1/4"to 47-1/2"(82.5 to 1,207 mm) Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths("A"Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing.Other approvals may be in process.Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S.and Canada. 6 Accepted for use, City of New York Department of Buildings,MEA 89-92-E,Vol. 2. 'cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) NOTE:When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. cULus Listina Reauirements: Standard Dry Horizontal Sidewall Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray horizontal sidewall sprinklers. • Limited to Light Hazard occupancies,where allowed by the installation standards being applied,with smooth ceilings only. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft.(1.8 m). • Deflector must be positioned between 4"and 6"(102 mm and 152 mm) below the ceiling. Keep the top of the deflector oriented parallel with the ceiling. • Locate no less than 4"(102 mm)from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F 091699 - Care and Handling of Sprinklers. Also refer to page DRYI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,whenever applicable. February 26, 2014 Sprinker 102e NEKiNG® STANDARD RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com • Approval Chart 2 (FM) Standard Response Dry Horizontal Sidewall Sprinklers f Temperature KEY ♦ ��Finish Maximum 175 PSI(12 bar)WWP A1Xf Escutcheon(if applicable( Sprinkler Thread Size Nominal K-Factorz Order Length Base Part SIN Style Increment FM Approvals' Number' NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) 07857U Adjustable 1" -- 5.6 80.6 1/2" 12 7 VK156 Al 07860U Standard -- 25 mm 5.6 80.6 1/2" 12.7 Al 07856U Adjustable 1" 5.6 80.6 1/4" 6.35 VK162 B2 07859U Recessed -- 25 mm 5.6 80.6 1/4" 6.35 63 07858U Plain 1" VK152 5.6 80.6 1/2" 12.7 A3 07861U Barrel -- 25 mm 5.6 80.6 1/2" 12.7 A3 Approved Finishes and "A" Dimensions Approved Temperature Ratings 1 -Brass, Bright Brass, Chrome, White Polyester, or ENT'with "A"dimensions 1-1/2" A- 155 °F (68 °C), 175 °F(79°C), 200°F(93°C), and to 45-1/2"(38.1 mm to 1,156 mm) 286 °F(141 °C) 2-Brass, Bright Brass, Chrome, White Polyester, or ENT5 with "A"dimensions 3-1/4" B- 155°F(68°C), 175°F(79°C),and 200°F(93°C) to 47-1/2"(82.5 mm to 1,207 mm) 3 - Brass, Bright Brass, Chrome, White Polyester, or ENT'with "A" dimensions 3" to 47"(76.2 mm to 1,194 mm) Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. K-Factor applies for standard lengths("A"Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. 5 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) NOTE:When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. FM ADoroval Reauirements: Dry horizontal sidewall sprinklers VK152.VK156,and VK162 are FM Approved as dry standard response Non-Storage sidewall sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(in- cluding Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to,but not limited to minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes,ordinances,and standards, whenever applicable. 1 Sprinkler 102f February 26, 2014 \Ilium. STANDARD RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com For 'A' Dimension: 1. Determine the distance from the face of the tee to the face of the finished wall. NOTE: To locate the 2. Round to the nearest 1/2' (12.7 mm) 11111111111111111111111111111111111111111E deflector at the between 1-1/2' (38.1 mm) and 45-1/2' \ T minimum distance (1,156 mm). L Finished Ceiling from the wall, NOTE: The deflector will extend approx- with no adjust meat available, imntely 4-1/4' (108 mm) from the wall Finished Wall order the stan- with 2' (+/- 1' (25.4 mm) of horizon- tal adjustment available. 4' (102 mm) Minimum 3-1/4 A 6' (152 mm) Maximum* (82.6 mm) 1 (25.sidewall sprinkler l' (25.4 mm) shorter Deflector at than the 'A' Minimum Distance 'A' dimension. From Wall fir' ' 1II ■ 5/8' (15.9 mm) t\ I I. 3-1/16' 111111111111101111011111111,111 „ „ "∎•t∎%`'` I (77.8 mn) NOTE, To locate the Minimum wall opening deflector at the P 9 I maximum distance diameter: 1-3/4' (44.5 mm) I L from the wall, Maximum wall opening l with no adjust- diameter: 2-1/4' (57 mm) Sleeve diameter: a I-I meat available, 13/16' 1-1/2' (38.1 mm). order the stan- (20.6 nn) Sleeve finish matches 5 1/a' dard horizontal finish of escutcheon. (133.4 mm) sidewall sprinkler ix May be allowed up to 18' (457 mm) for certain 1' (25.4 mm) longer Deflector at than the 'A' FM installations. Refer to the appropriate installation Maximum Distance 'A' dimension. standards, including NFPA 13 and/or FM Loss From wall Prevention Data Sheet 2-0. Figure 3: Adjustable Standard Dry Horizontal Sidewall Sprinkler VK156 111111111111111111111111111111 111111111111 11111111111111111111I11II1111111111111111E 111111IIIIIIIIIIIIIIIIII111111111111IIIIIE 4II1111I 1111111111111111111111111 1111 1111E Slot- _ — — i Slot Deflector i— Push and _ — / Ph _ �� Alb rotate swot ._ ! 0 'Al. - I Sleeve I i i i STEP 1: Align the slot in STEP 2: Push the rounded STEP 3: Pull the escutcheon STEP 4: Push and rotate STEP 5: To minimize the escutcheon with the end of the slot against the away from the near edge the escutcheon onto the visibility of the slot horizontal surface of near edge of the deflector. of the deflector. Move the sleeve, in the escutcheon, the deflector as shown. Push the Far side of the near side of the escut- position the slot escutcheon past the deflec- cheon over the deflector. at the top of the tor, toward the sleeve. sprinkler sleeve. Figure 4: Adjustable Standard Escutcheon Installation I February 26, 2014 Sprinker 102g IN j I KI NG* STANDARD RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com For 'A' Dimension' 1. Determine the distance from the face of the tee to the face of the finished wall. 1111111IIIIIIt111F 2. Round to nearest 1/4' (6.35 mm) between 3-1/4' (82.5 mm) and 47-1/2' (1,207 mm) Ceiling I NOTE: The sprinkler will be recessed approxi- Wall mately 5/16' (7.9 mm) with 5/8' (15.8 mm) horizontal adjustment available. 4' (102 mm) Minimum 6' (152 mm) Maximum( L A —I \���NV I 17 ( Ji1 5/8' (15.9 mm) r. I ] -- 3-1/16'NI F I �� Minimum ceiling opening' t 2-1/8' (54 mm) diameter. t t Maximum ceiling opening' 2-1/2' (63.5 mm) diameter. I Available Adjustment 1■ May be allowed up to 18' (457 mm) for certain I 1-7/8' (47.6 mm) Minimum FM installations. Refer to the appropriate Installation 2-1/2' (63.5 mm) Maximum standards, Including NFPA 13 and/or FM Loss 5/16' (7.9 mm) Outward Adjustment Prevention Data Sheet 2-0. 5/16' (7.9 mm) Inward Adjustment Figure 5: Adjustable Recessed Dry Horizontal Sidewall Sprinkler VK162 with the Model E-1 Escutcheon Side outlet of--� 1plwll Tee turned to 1, _\`1 req'd angle for �i W�,\1 For 'A' Dimension, slope of ceiling '1k1�'/1i,1'l1 1. Measure N Dimension from centerline of the face of the tee to the horizontal centerline 1i::. ,r'/ Adjustab(e� `%t�1 ,�� 2. Measure of the wail C Dimension opening. from the centerline of Adapter the Face of the tee to the finished wall Ring Il I q 3. Calculate A Dimension using: A = "1B2+C 2 ], NOTE.A Dimension will provide npproxkgtely 1/4' (6.33 M) of adjustment In either direction. ■ B Depth. 1-1/16' (27 nn) /�� 1/8' 7. '(3.2 mm) e ��� Ceiling Outer Cup I I I ��Q I l 41 ''''F F • Deflector distance �\ rte . �4-6' (102 to 152 mm) 2-5/8' 4. . - below the ceiling*. (66 ""') (IO2 "^) Minimum wall opening: - 9 When measuring for 2-5/8' (66 mm) diameter, the A Dimension, the Maximum well opening, exact deflector 3-3/4' (95 nm) diameter. ?r�Wall distance below the ceiling must be known. m _ 1-v^6'I C c May be allowed up to 18' (457 mm) (27 ) For certain FM installations. Refer to the appropriate Installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 6: Adjustable Recessed Dry Horizontal Sidewall Sprinkler VK162 with the Model G-1 Escutcheon Sprinkler 102h February 26, 2014 STANDARD RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com For 'A' Dimension: 111111111111111111111: 1. Determine the distance from the face of tee to the base of the sprinkler. Ceiling 2. Round to next highest 1/2' (12.7 mm) increment, between 3' (76.2 mm) and Wall 47' (1,194 mm), 4' (102 mm) Minimum 6' (152 mm) Maximum* A _ 2-7/16' .{ (61.9 mm) 5/8' (15.9 mm) Outside diameter: 1-5/16' (33.4 mm). (Same as 1' Do not exceed 6' (152 mm). (25 mm) Schedule 40 pipe. Do not recess wrench boss. NE May be allowed up to 18' (457 mm) for certain FM installations. Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 7: Plain Barrel Dry Horizontal Sidewall Sprinkler VK152 Top View- Dry HSW Sprinkler Side View-Sprinkler Cover 15610 NOTE: Shown with an Adjustable Standard Dry HSW Sprinkler. The protective cover may also be used with the Adjustable Recessed or Press the cover together Plain Barrel style Dry HSW Sprinkler. U until it snaps closed. • 8.p •Y 1" After the sprinkler is installed, carefully place the cover over ' NOTE: Remove the sprinkler clip and cover the dry sprinkler as shown. before placing the system in service! Figure 8: Dry Horizontal Sidewall Sprinkler Cover Part Number 15610(shown with an Adjustable Standard Dry HSW Sprinkler) (Optional for temporary use with Viking Dry HSW Sprinklers until finish work is completed around the sprinkler.) I February 26, 2014 Sprinker 102i NIKING. STANDARD RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs @vikingcorp.com MO 5-1/4' Seal the clearance space around the sprinkler barrel to avoid (133.4 mm) leakage of air into the protected area and consequent formation Maximum of condensate around the sprinkler frame, which could Inhibit oper- ation or cause premature operation. Refer to Figure 10 below. IF humidity and temperature ,� 1 • differential causes condensation ,,,, 1 '' on the exposed dry sprinkler 1111 = ITN 'barrel, consider wrapping the 1111 =exposed barrel with insulation, 1111 = NOTE To locate the foam insulating tape, 1111 / Deflector at deflector at the or equivalent. 1111 13/16' Maxinun Distance maximum distance From ;In (20.6 mm) Ceiling From Vali the wall, with no Install 1 Inch NPT threaded ilii 4' (102 mm) Minimum adjustment available, ye 6' <152 nn) Maximums order the standard end of dry sidewall sprinkler ,1 - dry horizontal side- Up the 1 inch NPT outlet of �i;; Up to 2' (50,8 mm) wall sprinkler 1' a malleable iron tee fitting t1 of adjustment longer than the 'A' per ANSI B 16.3 (Class 150) or ����� dimension. cast Iron threaded tee fitting •'\ I I I is available. 5/8' (153 mm) per ANSI 16.4 (Class 125) only. �\\II �...•.��� i I 3-1/16' Minimum wall opening / (77.8 mm) 3-1/4' NOTE: To locate the diameter, 1-3/4' (445 nm� �� J (826 mm) deflector at the (Exposed ', Minimum minimum distance from Maximum wall opening 1-1/2' (38.1 mm) diameter, 2-1/4' (57 rim). Barrel) ,l' (Protected the wall, with no Area) diameter. Sleeve adjustment available, finish matches , r order the standard Ambient Ex sed Harr escutcheon finish I 1 dry horizontal side- Ambient Temperature Surface 1 Temperature p Surface snot sprinkler 1' of Protected 40'F/4•450'F/10•C160'F/16Y of the \Wall MO shorter than the Areaww at the Exposed Minimum Barrel 'A' dimension. Discharge End Lengthww■Face of the Deflector at of the Sprinkler Tee to the Outer Minimum Distance Surface of the Vall From Vali In.(re)_in.(nn) In.(ccl 40'F (4'C) 0 0 0 *May be allowed up to 18' (457 mm) for certain FM 30'F (-1'C) 0 0 0 installations. Refer to the appropriate installation standards, 20'F (-7•C) 4 (100) 0 0 Including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. 10'F (-12•C) 8(203) 1(25.4) 0 0'F <-18'G 12 (305) 3 (76) 0 wwThe protected area refers to the area below the ceiling, -10•F (-23'C)14 (356) 4(102) I (25.4) The ambient temperature is the temperature at the discharge end of the sprinkler. -20'F (-29'C)14 (356)6 (152) 3 (76) For protected area temperatures that occur between the values listed, use the next cooler temperature. -30'F C-34'0 16 (406)8 (203)4 (102) *wwThe minimum required barrel length is not the same as the 'A' dimension, -40•F (-40'C)18 (457)8(203)4 (102) -50'F C-46'0 20(508)10(254)6 (152) Refer to Figures 3, 5, and 7 for the 'A' dimension. -60•F (-51'C)20(508)10 (254)6 <152> Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 9: Dry Horizontal Sidwall Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry HSW Sprinkler is Shown) Seal ` Seal z (or equivalent , C . k r)ethod) i; L III II;■I�NI ■; , 111 II! i ■�1 I : . Clearance j Opening 1 ■ Insulated 2 k Wall Insulated Wall Dry Sprinkler Seal on the Exterior of the Wall Dry Sprinkler Seal Within the Wall Figure 10: Dry Sprinkler Seal(Adjustable Standard Dry HSW Sprinkler is Shown) Form No. F_073091 Replaces page 102a-i, dated July 17, 2013. (Removed Seal Part Number) VicFlex M Sprinkler Fittings Jctaulr,c- Series AH1, AH2 and AH4 Braided Flexible Hose Assemblies 10.85 •Brackets: 11111 Style AB1 for suspended and hard-lid ceilings, allows VIC installation before ceiling tiles in place Mopp".=;;Iip. „... ow. Style AB2 for hard-lid ceilings,allows for vertical sprinkler adjustment Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment Approvals/Listings: Style AB7 for suspended ceilings and hard-lid ceilings 4 e@us CB Style AB7 Adjustable for suspended and hard-lid ceilings Style AB8 for hard-lid ceilings(regionally available) See Victaulic Publication 10.01 for more details. Style AB9 for hard-lid ceilings with hat furring channel grid systems Product Description: Style AB10 for Armstrong®TechZone'"'ceilings VicFlex sprinkler fittings provide sprinkler installation on suspended ceiling grids, wood or metal stud/joist or hat furring channel hard-lid ceilings utilizing a flexible, stainless steel hose and steel bracket assembly. Refer to the Installation Manual for all applicable ASTM ceiling material and installation standards. System Components • Hoses: Series AH1 Braided Hose Series AH2 Braided Hose Series AH4 Braided Hose Assembly lengths: 31, 36,48, 60, 72790,914, 1220, 1525, 1830mm. Note: length includes branch-line nipple and 5.75"/140mm straight reducer. •Sprinkler Reducers: W and W/15 and 20 mm sprinkler connections and 5.757140mm,9"/230mm, 137330mm straight lengths and short, long 90° elbows. Note: The short 90°elbow is typically used with concealed sprinklers while the long 90°elbow is typically used in the installation of recessed pendent sprinklers. • Branch Connections: 1"/25mm NPT or BSPT branch line nipples for attaching to rigid pipe. 3 /20mm NPT or BSPT available for VdS. Job/Owner Engineer System No. Spec Section Location Paragraph L Contractor Approved Submitted By UciIc Date victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 10.85 5839 Rev U Updated 08/2014 0 2014 Victaulic Company.All rights reserved. 1 .ctaulic victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 Technical Specifications: Material Specifications: Maximum Working Temperature: 225°F/107°C • Series AH1 Maximum Working Pressure: Flexible Hose: Type 304 Stainless Steel • 200 psi/1375 kPa (FM Approval) Collar/Weld Fitting: Type 304 Stainless Steel • 175 psi/1206 kPa (cULus Listed -Series AH2 only) • 1600 kPa/232 psi (VdS Approved) Gasket Seal: Victaulic EPDM Connections: Isolation Ring: Nylon To branch line (inlet) via 1 725.4 mm NPT or BSPT male Nut and Nipple: Carbon Steel, Zinc Plated thread OR Reducers(1/2 or 3/a"): Carbon Steel, Zinc-Plated To branch line (inlet) via 3/a"/20 mm BSPT male thread • Series AH2 (VdS only) To sprinkler head (outlet)vial" or 34"/15 mm or 20 mm Flexible Hose: Type 304 Stainless Steel NPT or BSPT female thread Collar/Weld Fitting: Type 304 Stainless Steel Minimum Bend Radius: Gasket Seal: Victaulic EPDM • 7"/178 mm (FM Approval) Isolation Ring: Nylon • 2"/51 mm (cULus Listed - Series AH2 only) • 3 776.2 mm (cULus Listed - Series AH1 only) Nut and Nipple: Carbon Steel, Zinc Plated •3776.2 mm (VdS Approved) Reducers ('/z or 3/a"): Carbon Steel, Zinc-Plated Maximum Allowable Sprinkler K-Factors: • Series AH4 • FM (W/15mm reducer) K5.6/8,1 (S.I.) (34720mm reducer) K14.0/20,2 (S.I.) Flexible Hose: Type 304 Stainless Steel • cULus (1"/15mm reducer) K8.0/11,5(S.I.) Collar/Weld Fitting: Type 304 Stainless Steel (3/a"/20mm reducer) K14.0/20,2 (S.I.) •VdS (1/2"/15mm reducer) K5.6/8,1 (S.I.) Gasket Seal: EPDM per ASTM D2000 (34720mm reducer) K8.0/11,5(S.I.) Isolation Ring: N/A Nut and Nipple: Carbon Steel, Zinc-Plated Reducers(1 or 3/a"): Carbon Steel, Zinc-Plated • Brackets: Carbon Steel, Zinc-Plated victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 l us FRICTION LOSS DATA: p�O -Series AH2 Braided Hose with Straight 5.75" Reducers -Style AB1 and AB10 Brackets Series AH2 Hose Maximum Length of Equivalent Length Number of Stainless Steel of 1"/33.7mm 90°Bends at 2"/51mm Flexible Hose Oulfet Sae Sch.40 Pipe(C=120) Bend Radius inches inches/type feet/meters 31 W/Straight 16/4.9 4 3/4"/Straight 17/5.2 j 4 36 W/Straight 21/6.4 5 W/Straight 23/7.0 5 48 16'/5traight 32/9.8 8 lie/Straight 37/113 8 14"/Straight - 46/14.0 10 3/4"/Straight _ 46/14.0 - 10 72 W/Straight _ 55/16.8 - 12 W/Straight 53/16.2 12 Series AH2 Braided Hose Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2'/51mm center line bend radius Length of ! 1 Stainless Steel Flexible Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Hose Size 0 Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches inches feet/meters 31 /' 5.0/15 8.5/2.6 11.0/3.4 13.0/4.0 16.0/4.9 NA NA NA NA NA NA NA NA 14' 6.5/2.0 10.0/3.0 123/3.8 14.0/43 17.0/5.2 NA N.A NA NA • NA NA NA NA 36 W 105/3.2 135/4.1 16.0/4.9 18.0/5.5 19.0/5.8 21.0/6.4 N.A . NA NA NA NA NA NA W 12.0/3.7 14.0/4.3 17.0/5.2 19.5/5.9 20.0/6.1 23.0/7.0 N.A NA NA NA NA NA NA 12' 115/3.5 155/4.7 17.0/52 19.5/5.9 20.0/6.1 21.0/6.4 22.0/6.7 28.0/83 32.0/9.8 NA , NA NA NA W 13.0/4.0 17.0/5.2 19.0/5.8 21.5/6.6 24.5/7.5 26.0/7.9 27.0/8.2 30.0/9.1 37.0/113 NA NA NA NA W 153/4.7 215/6.6 24.0/73 27.0/8.2 285/8.7 30.0/9.1 31.0/9.4 37.0/113 42.0/12.8 44.0/13.4 46.0/14.0 NA NA 60 W 16.0/4.9 23.0/7.0 24.0/73 28.0/8.5 295/9.0 305/93 31.0/9.4 38.0/11.6 42.0/12.8 44.0/13.4 46.W14.0 NA NA 72 W 283/8.7 30.0/9.1 32.0/9.8 365/11.1 375/11.4403/123 41.0/12.8 42.0/12.8 46.0/14.0 49.0/14.9 52.0/15.8 54.0/163 55.0/16.8 W 24.0/73 32.0/9.8 325/9.9 35.0/10.7 353/10.8 40.0/123 403/123 41.0/123 46.0/14.050.0/152 51.0/155 52.0/15.8 53.0/162 Note:Values for use with 5.75'straight reducers. How to use this Design Guide: 1 For some systems,it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends.In this case,the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. 2 It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected.When this happens,the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations.The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 10.85 5839 Rev U Updated 08/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 3 jctauIuc victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 Ous FRICTION LOSS DATA: ustEn -Series AH1 Braided Hose with Straight 5.75"Reducers -Style AB1 and AB1)Brackets Series AH1 Hose I Maximum Length of Equivalent Length Number of Stainless Steel of 1%33.7mm 90°Bends at 3"/76.2mm Flexible Hose Outlet Size Sch.40 Pipe(C=120) Bend Radius inches inches/type feet/meters 31 'I"/Straight 52/15.8 3 %%Straight 55/16.8 3 1/2"/Straight 63/19.2 4 %%Straight 66/20.1 4 %%Straight 78/23.8 4 %/Straight 80/24.4 4 W/Stralght 88/26.8 - 4 - %Strai4ht 90/27.4 4 72 '%%Straight 112/34.1 5 se/Straight 118/36.0 5 Series AH1 Braided Hose Equivalent Length Design Guide Length of i Stainless Steel Flexible Outlet 1 2 3 4 5 Hose Size 0 Bends Bends I Bends Bends Bends Bends inches inches feet/meters I 31 W 22 32 42 52 NA NA 1 314' 22 33 44 _ 55 NA NA W 23 33 43 53 63 NA 36 W 26 36 46 56 66 NA W 36 46 57 68 78 NA 48 314' 40 51 60 71 80 NA IA' 46 56 67 77 88 NA 60 W 47 58 69 80 90 NA 72 1h' 59 69 79 91 102 112 314' 62 73 84 95 106 118 • Note:Values for use with 5.75'straight reducers. How to use this Design Guide: 1 For some systems,it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends.In this case,the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. 2 It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected.When this happens,the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations.The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 10.85 b839 Rev U Updated 08/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 etalluIi4'r victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 11> FRICTION LOSS DATA: -Series AH1, AH2 and AH4 Braided Hose -Various brackets specific to hose Series AH1 Hose Series AH2 Hose I Series AH4 Hose For use with Style AB1,AB2, For use with Style AB1,AB2, AM,A87,AB7 Adj.,AB8,AB9 AB4,AB7,AB7 Adj.,AB8,AB9 For use with Style AB1,AB7,AB8, and*810 VicFlex Brackets and AB10 VicFlex Brackets and AB9 VicFlex Brackets Length of Maximum Maximum Maximum Stainless Equivalent Number of Equivalent Number Equivalent Number Steel Length of 90°Bends at Length of of 90°Bends at Length of of 90°Bends at Flexible Sprinkler Outlet 1"/33.7mm 7"/178mm Bend 1"/33.7mm 7'/178mm 1"/33.7mm 7"/178mm Hose* K-Factor Size Sch.40 Pipe Radius Sch.40 Pipe Bend Radius Sch.40 Pipe Bend Radius inches Imperial/S.I. inches/type feet/meters feet/meters feet/meters 1/2'/Straight 53.8/16.4 235/7.1 20.6/6.3 31 5.6/8.1 2 2 WElbow 53.8/16.4 23/7.0 21.7/6.6 1/2"/Straight 63.7/19.4 27.8/85 29.7/9.0 36 5.6/8.1 Wes.Elbow 63.1/192 2 27.7/8.4 2 29.8/9.0 'k"/Stralght 87.9/26.8 382/116 27.5/8.3 48 5.6/8.1 l,5'/90°Elbow 85.8/26.1 3 _ 37.4/11.4 1 3 29.2/8.9 3 _ 'A"/Straight 112.2/34.1 42.4/12.9 35.7/10.9 60 5.6/8.1 ,/,/90°Elbow 108.4/33.0 4 ___1 43/13.1 4 37.2/11.3 4 1/2"/Straight 136.5/41.6 46.6/142 _45.9/14.0 72 5.6/8.1 y=•/90°Elbow 131.1/39.9 4 48.5/14.7 4 47.5/14. 4 34"/Straight 44.4/135 20.7/63 133/4.0 31 84/11.5 14'/90°Elbow 47.6/145 2 _ 205/62 2 14.6/4.4 2 34"/Straight 55.6/16.9 25.0/7. _ 21.7/6.6 36 84/115 -3./90'Elbow 575/175 2 24.6/7.5 2 22.4/6.8 2 _34'/Straight 82.8/25.2 353/10.8 21.2/6.4 48 80/115 34•/90°Elbow 81.7/24.9 3 34.7/10.6 3 _ 222/6.7 3 _34"/Straight 110.1/335 39.6/12.1 27.9/8.5 60 84/11*". 34"/90°Elbow 105.9/32.2 4 40.1/12.2 4 28.9/8.8 4 _x/1'/Straight 137.3 435/13.2_ 38.8/11.8 72 80/115 14"/90°Elbow 1302/39.7 4 45.2/13.7 4 39.4/120 4 31 112/161 3''"/Straight 45.5/13.8 2 17.8/5.4 2 16.4/5.0 2 34'/90°Elbow 47.1/143 18/53 _ 19.9/6.1 _ 34"/Straight 66.3/20.2 22.2/6.7 21.7/6.6 36 111/161 W/90 Elbow ' 57.5/17.5 2 22.1/6.7 2 24.2/7.4 2 34•/Straight 82.7/25.2 32.9/10.0 285/8.7 48 11.2/16.1 /90 Elbow 82.8/25.2 3 32.1/9.8 3 29.9/9.1 3 � 34'/Straight_109.1/332 36.8/11.2 34.7/105 60 112/161 x./90-Elbow 108.1/32.9 _ 4 37.1/113 4 30.3/9.2 4 34"/Straight 1355/413 405/12.3 38.6/11.6 72 112/16.1 3/4790-Elbow 133.4/40.6 4 41.9/12.7 - 4 -_386/11.7 4 31 14.0/20.2 34"/Straight 44.3/13.5 2 _14.9/45 2 16.3/5.0 2 34"/90'Elbow 46.4/14.1 155/4.72 _ 19.9/6.1 _ 34'/Straight 55.5/16.9 19.4/5.9 21.8/6.7 36 144/201 I4790-Elbow 56.7/173 2 19.6/5.9 2 24.2/7.4 2 IV/Straight _ _83.0/253 303/9.2 _ 283/8.6 _ 48 14.0/202 W . ]Elbow 82.1/25.0 3 295/8.9 3 _ 29.9/9.1 3 IV/Straight 110.4/33.6 _33.9/10.3 34.9/10.6 60 14A/20.Z Wes-Elbow 1075/32.7 4 34.1/10.4 4 303/92- 4 34•/Straight 137.9/42.0 37.5/11.4 413/12.6 72 1441201 '1"/90'Elbow 132.8/40.4 4 38.6/11.7 4 38.6/11.7 4 FM Nobs: Series AH1,AH2 and AH4 have been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 130 and FM data sheets 2-0,2-5,and 2-8.FM 1637 and Vds standards for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance,leakage,mechanical and hydrostatic strength. Differences in equivalent lengths are due to varying test methods,per FM 1637 and VdS standards.Refer to these standards for additional information regarding friction loss test methods. EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends at a 7-inch bend radius is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. 10.85 5839 Key U Updated 08/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 5 victaulia victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 VdS FRICTION LOSS DATA: , -Series AH1, AH2 and AH4 Braided Hose -Style AB1, AB2, AB4, AB7, AB7 Adj., AB8, AB9, and AB10 Brackets Series AH1 Hose _ Series AH2 Hose Series AH4 Hose Equivalent Length of Equivalent Length of Equivalent Length of steel pipe according to steel pipe according to steel pipe according to EN 10255 DN 20 EN 10255 DN 25 EN 10255 DN 25 Maximum Number (26,9 x 2,65)and (33,7 x 3,25)and (33,7 x 3,25)and of 90°Bends at Length of Stainless Outlet relating to a flow relating to a flow relating to a flow 3"/76.2mm Bend Steel Flexible Hose Size velocity of 5 m/s velocity of 5 m/s velocity of 5 m/s Radius mm/inches mm/inches type meters/feet meters/feet meters/feet 790/31 15mm/'h"/Straight 4.0/12.9 5.5/18.0 55/18.0 3 20 mm/i4'/Straight _ 915/36 15mm/'f.'/Straight 4.6/15.0 6.4/21.0 6.4/21.0 3 20 mm/'14'/Straight 1220/48 15mm/'fi'/Straight 6.1/20.0 85/27.9 85/27.9 3 20 mm/14'/Straight - 1525/60 15mm/1/2'/Straight 7.6/25.0 10.7/35.1 10.7/35.1 4 20 mm/i4'/Straight 1830/72 15mm/WI Straight 9.2/30.0 12.8/42.0 12.8/42.0 4 20 mm/16'/Straight _ VdS Ceiling Manufacturers List AB1,AB2,AB7,AB10 AB3 AB4/9 A88 1.AMF No specific approval No specific approval 1.Hilti 2.Armstrong 2.Knauf 3.Chicago Metallic 3.Lafarge 4.Dipling 4.Lindner 5.Durlum 5.Rigips 6.Geipel 7.Gema-Armstrong 8.Hilti 9.Knauf 10.Lafarge 11.Linder 12.Odenwald 13.Richter 14.Rigips 15.Rockfon Pagos 16.Suckow&Fischer 17.USG Donn victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 Product Details- Series AH1 Braided Hose Series AH2 Braided Hose Series AH4 Braided Hose Item Description 49 O O 0 0 1 flexible Hose 2 Isolation Ring(series AH2 only) 111.:il'I11M■�14►iuumi11iim,m,„110,111 3 Gasket A 4 Nut B 5 Branch Line Nipple 6 Braid Hose Length Dimensions 7 Collar/Weld fitting 8 Sleeve(AH2 Only) Hose Length A B 31 25.25 31 36 31.25 36 48 42.25 48 60 54.25 60 72 66.25 72 Standard 111H1 111 5.75"/140 mm straight reducer Optional 1C '=11 9.0"/229 mm straight reducer 1G II 13.0'/330 mm straight reducer 2.62"/ 2.627 665 mm 665 mm 630'/ 4.83? 160.0 mm 122.7 mm IBM Short 90°elbow reducer Long 90°elbow reducer Note:The Short 90°elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 VicFlex Brackets Style AB1 p • Suspended Ceilings `y • Hard-Lid Ceilings (FM Only) Item Description 4� 1 24"/610mm or 48"/1219mm Square Bar* i ►t 2 Patented 1-Bee"Center Bracket 3 End Bracket *Both sizes FMNdS approved,cULus listed 0 1 ft. ifrii Style AB2 iK • Hard-Lid Ceilings 4, Item Description illitil°111114 ( 1 24"/610mm or 48"/1219mm Square Bar' 2 Patent-Pending adjustable Center bracket p 3 End Bracket 'Both sizes FM/VdS approved. ,r ••:- • - Note: She or 4mm hex key required for adjustment 17 O Style AB4 1.- • Hard-Lid Ceilings with Hat furring channel grid system I Item Description %,N...,,, \ 1 24"/610mm or 48"/1219mm Square Bar" .1 19 2 Patent-Pending adjustable Center bracket 3 End Bracket for Hat Furring Channel X'..�` 'Both sizes FM/VdS approved. . � Note: Via or 4mm hex key required for adjustment O victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 VicFlex Brackets Style AB7 in • Suspended Ceilings • Hard-Lid Ceilings • v' Item Description .^ 1 24"/610mm or 48"/1219mm Square Bar' 2 Patented 1-Bee'•Center Bracket 3 End Bracket �t�`�J 'both sues F M/VdS approved. 'e �� O Style AB7 Adjustable 3 •- •Suspended Ceilings , ;, • Hard-Lid Ceilings . Item Description © 1#1, 1 700mm or 1400mm Square Bar" 2 Patented 1-Bee2°Center Bracket ��� 3 End Bracket(adjustable) .,„A\�_i`{' 0 *Both sizes FM and VDS approved. r Style AB8 '`�� • Hard-Lid Ceilings �4.1• Item Description .. 1 700mm or 1400mm Square Bar• 2 Patented 1-Bee'•Center Bracket 3 i End Bracket(adjustable) - - *Both sizes FMNdS approved. i Style AB9 • Hard-Lid ceilings with Hat furring channel 0 4+ J grid system ...! �\ Item Description 1 24'/610mm or 48Y1219mm Square Bar` 2 Patented 1-Bee"Center Bracket �.. 3 End Bracket for Hat Furring Channel V li *Both sizes FMNdS approved. •�` O Style AB10 �j • Suspended ceilings ��.��0, • Armstrong®TechZone'" (9 C���\0 0 0, Item Description •4 ter 0 �, 1 6'7152mm Square Bar" Y� ' 2 Patented 1-Bee' Center Bracket j 3 End Bracket 'FMNdS approved,cULus listed. 1�gf 10.85 5839 Rev U Updated 08/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 9 t9ul, C •C victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 Braided Hose Assembly Suspended Ceiling Grid with Recessed Sprinkler - Clearances above ceiling tile at various center-line bend radii -----I I Hose Clearance Chart 7 R / See chart Dimension Inches/mm Minimum Bend 2/50 3/80 4/100 5/125 W150 7/175 ___ Radius It" A r See Char: •MI• Braeketassemby Minimum A' 10.75/273 11.75/298.5 12.75/324 13.75/349 14.75/375' 15.75/400 rL� 4"A81 ■_ < TT] II 4 4'/ -- 113Imm _ sh%16 mm U Tri } ( r cM mg rile 17743 mm ,i.7•II Typical ceiling grid , WWII _ 14eFt' Finished See note ���� ceiling face 247610 mm or 48712I9mm on Center V2707 Mr/19 MM MAX.RECESS V2707 3,4719mm Max. Recess Suspended Ceiling Grid with 90°Elbow (Long) 11:1111 Bracket assembly Style ABI '- Hose Clearance Chart • all Inches/ seecr,art III t!TI IM■SM Dimension mm 447 13mm A Min. 200 3/4716 mfr ceiMr o rile ir Note: Style AB1 and Series AH2 figures shown. "'/4°Tm 11± .i Typal ceLng grid� "Y-+,! Variations of ceiling grids, sprinkler heads, brackets, — -i1!7 �n� Finished and hoses are permitted but may result in clearance seenote ceiling lace 24%610 mm differences from the figures above. or4871219min on Center V2707 3,44719mm Max. Recess victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 Series AQB Braided Hose Assembly Suspended Ceiling Grid with Hat Furring Channel Hose Clearance Chart Dimension Inches/mm Minimum Bend Radius"R" 2/50 3/80 4/100 5/125 6/150 7/175 / " � See Minimum"A" 10.3/262 11.3/287 12.3/313 13.3/338 143/363.51 153/389 1 \ U. -- KIWI See Chat 1 ,r, 97 mm i6, / \ See Nae _- Mini !- 1 ■■ !_.. 1 1' N V2708 W/12.7mm Max. Recess Suspended Ceiling Grid with 90°Elbow(Short) II7!I 'I� Hose Clearance Chart Inches/ Dimension mm ��,� III IL" 8 i9./ =∎� _f•7 r -•NM See Chart A Min. 200 99 mm ��._ iv j See Note: Style AB9 and Series AH2 figures shown. L,,.1 'I i:P_I.∎ r1. Variations of ceiling grids, sprinkler heads, brackets, \ ' 16411 and hoses are permitted but may result in clearance .\.._ _i differences from the figures above. V3802 W/12.7mm Max.Recess HYDRANT FLOW REQUEST FORM PROJECT: TIGARD FIRE STATION ADDRESS: 8935 SW BURNHAM ST TIGARD OR CROSS STREET: FLOW HYDRANT LOCATION: NE CORNER OF FIRE STATION STATIC: 104 RESIDUAL: 92 GPM: 1610 @ 20 PSI = 12,112 GPM DATED: 09.18.14 12:30 PM MONITOR HYDRANT LOCATION: NW CORNER OF FIRE STATION STATIC: 104 RESIDUAL: 102 GPM: DATED: 09.18.14 .t 0965 02A0222 — 6- DU 02A0290 Q2A0221— [eV • / Monitor Hydrant ""*" ..---F------.1ow Hydrut t ) az. ,2 :2A02139 02A0218 02A02 40 2A0207 + 0 , ‘,.. 0.7A0214 04210 •. gq 02A0217 4■4•?■ c/, .., le, It "Y. ,, 1,, 6',.. 0 4t, % Nie , Feet E 3 .1•511111i 1 , HYDRAULIC CALCULATION SUMMARY SHEET ***TVFR #51 New Area*** PROJECT NAME:--> TVFR #51 PROJECT ADDRESS:--> 8935 SW Burnham st. DRAWING SHEET NUMBER:--> FP2.1 DATE CALCULATED:--> 9/23/2014 AUTHORITY HAVING JURISDICTION:--> City Of Tigard SYSTEM INFORMATION: Size Of System: > 10,512 sq. ft. +/- Type Of System: > Wet Vol. Of Dry/Preaction/Anti-freeze Syetem: > N/A gallons Available Pressure > 103.6 psi Required Pressure > 88.8 psi Safety Factor > 14.8 psi / 14% DESIGN DATA: Remote Area Number: > #1 Remote Area Location: > Fitness/Dining pR Occupancy Classification: > Light Q.�I ac& Storage Commodity Classification: > N/A ���4, sU0 Storage Height: > N/A :1/ 13; Density: > .10 gpm/900 Area Of Application: > 981 SQ. FT. (2-31 j-. Coverage Per Sprinkler: > 225 sq. ft. max. OREGON Type Of Sprinkler Calculated: > Q.R. SSU VK302 ♦ ri0, ',� Sprinkler K-Factor: > 5.6K 4A, M Number Of Sprinklers Calculated: > 7 /O 021 (4 In-Rack Sprinkler Demand: > N/A Number Of In-Rack Sprinklers Calculated: > N/A Hose Streams Inside + Outside: > 100 gpm Total Water Required (including hose) : > 243.2 Flow And Pressure At Base Of Riser: > 143.2 gpm @ 86.7 psi WATER SUPPLY: Static psi:---> 104 Residual psi:--> 92 Flowing GPM:--> 1610.0 GPM @ 20 psi:--> 12, 112 Test Date:----> 9/18/2014 Location: > NE corner of Fire Station Info From: > City of Tigard Water Dept PUMP INFO: Pump Type:--> N/A PSI Rating:--> N/A GPM Rating:--> N/A INSTALLING CONTRACTOR: Name: > Viking Automatic Sprinkler Co. Address: > 3245 NW Front Avenue, Portland, OR 97210-1509 Phone: > (503) 227-1171 Fax:--> (503) 227-1552 Designer: > Dave Bateman Oregon CCB#: > 64837 Washington Lic.#:--> VI-KI-NA-5373NT Calculations performed by HASS 8.4 under license # 38030713 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 9/24/2014BS\HYDRAULIC CALCULATION\TVFR #51\TVFR 51 .10-NEW AREA.SDF JOB TITLE: TVFR 51 .10-900 new area WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 104.0 92.0 1610.0 103.6 243.2 88.8 Required pressure is 14.8 psi (14%) less than available pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 243.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 143.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 9.0 K= 5.60 10.9 18.5 2 9.0 K= 5.60 11.9 19.3 3 9.0 K= 5.60 15.7 22.2 4 9.0 K= 5.60 15.0 21.7 5 10.0 K= 5.60 9.3 17.1 6 10.0 K= 5.60 8.4 16.2 7 8.5 K= 5.60 25.3 28.2 lA 9.0 - - - - 14.4 - - - 2A 9.0 - - - - 15.7 - - - 3A 9.0 - - - - 20.6 - - - 4A 9.0 - - - - 19.7 - - - 5A 10.5 - - - - 12.1 - - - M1 9.0 - - - - 24.8 - - - M2 12.3 - - - - 30.6 - - - M3 10.7 - - - - 61.2 - - - M6 11.3 - - - - 69.8 - - - M7 11.3 - - - - 74.6 - - - TOR 11.3 - - - - 74.7 - - - BF1 2.5 - - - - 85.9 - - - BF2 2.5 - - - - 78.9 - - - BOR 0.8 - - - - 86.7 - - - SRC -4.0 SOURCE 88.8 143.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 9/24/2014BS\HYDRAULIC CALCULATION\TVFR #51\TVFR 51 .10-NEW AREA.SDF JOB TITLE: TVFR 51 .10-900 new area PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -18.5 1.049 PL 26.00 PF 3.5 1 9.0 5.6 10.9 18.5 6.9 120 FTG T PE 0.0 1A 9.0 0.0 14.4 0.0 0.113 TL 31.00 PV Pipe: 2 -19.3 1.049 PL 26.00 PF 3.8 2 9.0 5.6 11.9 19.3 7.2 120 FTG T PE 0.0 2A 9.0 0.0 15.7 0.0 0.122 TL 31.00 PV Pipe: 3 -22.2 1.049 PL 26.00 PF 4.9 3 9.0 5.6 15.7 22.2 8.2 120 FTG T PE 0.0 3A 9.0 0.0 20.6 0.0 0.158 TL 31.00 PV Pipe: 4 -21.7 1.049 PL 26.00 PF 4.7 4 9.0 5.6 15.0 21.7 8.1 120 FTG T PE 0.0 4A 9.0 0.0 19.7 0.0 0.151 TL 31.00 PV Pipe: 5 -17.1 1.049 PL 26.50 PF 3.1 5 10.0 5.6 9.3 17.1 6.3 120 FTG T PE -0.2 5A 10.5 0.0 12.1 0.0 0.097 TL 31.50 PV Pipe: 6 -16.2 1.049 PL 38.50 PF 4.0 6 10.0 5.6 8.4 16.2 6.0 120 FTG ET PE -0.2 5A 10.5 0.0 12.1 0.0 0.088 TL 45.50 PV Pipe: 7 -18.5 1.049 PL 11.50 PF 1.3 1A 9.0 0.0 14.4 0.0 6.9 120 FTG ---- PE 0.0 2A 9.0 0.0 15.7 0.0 0.113 TL 11.50 PV Pipe: 8 -37.8 1.049 PL 11.50 PF 4.9 2A 9.0 0.0 15.7 0.0 14.0 120 FTG ---- PE 0.0 3A 9.0 0.0 20.6 0.0 0.423 TL 11.50 PV Pipe: 9 -60.0 1.380 PL 10.12 PF 4.2 3A 9.0 0.0 20.6 0.0 12.9 120 FTG T PE 0.0 M1 9.0 0.0 24.8 0.0 0.261 TL 16.12 PV Pipe: 10 -55.0 1.049 PL 1.00 PF 5.1 4A 9.0 0.0 19.7 0.0 20.4 120 FTG T PE 0.0 M1 9.0 0.0 24.8 0.0 0.845 TL 6.00 PV Pipe: 11 -33.3 1.049 PL 11.75 PF 6. 9 5A 10.5 0.0 12.1 0.0 12.4 120 FTG 2ET PE 0. 6 4A 9.0 0.0 19.7 0.0 0.334 TL 20.75 PV Pipe: 12 -28.2 1.049 PL 16.00 PF 6. 9 7 8.5 5.6 25.3 28.2 10.5 120 FTG E2T PE -1.7 M2 12.3 0.0 30.6 0.0 0.246 TL 28.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 9/24/2014BS\HYDRAULIC CALCULATION\TVFR #51\TVFR 51 .10-NEW AREA.SDF JOB TITLE: TVFR 51 .10-900 new area PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -115.0 1.610 PL 5.58 PF 7.2 M1 9.0 0.0 24.8 0.0 18.1 120 FTG ET PE -1.4 M2 12.3 0.0 30.6 0.0 0.411 TL 17.58 PV Pipe: 14 -143.2 1.610 PL 36.58 PF 29. 9 M2 12.3 0.0 30.6 0.0 22.6 120 FTG ET PE 0.7 M3 10.7 0.0 61.2 0.0 0.616 TL 48.58 PV Pipe: 15 -143.2 2.067 PL 28.33 PF 8.8 M3 10.7 0.0 61.2 0.0 13.7 120 FTG 2ET PE -0.3 M6 11.3 0.0 69.8 0.0 0.183 TL 48.33 PV Pipe: 16 -143.2 2.067 PL 16.58 PF 4.9 M6 11.3 0.0 69.8 0.0 13.7 120 FTG T PE 0.0 M7 11.3 0.0 74.6 0.0 0.183 TL 26.58 PV Pipe: 17 -143.2 3.260 PL 4.62 PF 0.1 M7 11.3 0.0 74.6 0.0 5.5 120 FTG ---- PE 0.0 TOR 11.3 0.0 74.7 0.0 0.020 TL 4.62 PV Pipe: 18 -143.2 3.260 PL 8.83 PF 0.4 TOR 11.3 0.0 74.7 0.0 5.5 120 FTG 2E PE 3.8 BF2 2.5 0.0 78.9 0.0 0.020 TL 18.83 PV Pipe: 19 FIXED PRESSURE LOSS DEVICE BF1 2.5 0.0 85.9 0.0 7.0 psi, 143.2 gpm BF2 2.5 0.0 78.9 0.0 Pipe: 20 -143.2 4.100 PL 1.75 PF 0.0 BF1 2.5 0.0 85.9 0.0 3.5 140 FTG ---- PE 0.8 BOR 0.8 0.0 86.7 0.0 0.005 TL 1.75 PV Pipe: 21 -143.2 6.280 PL 80.00 PF 0.1 BOR 0.8 0.0 86.7 0.0 1.5 140 FTG ET PE 2.1 SRC -4.0 SRCE 88.8 (N/A) 0.001 TL 136.00 PV NOTES (HASS) : (1) Calculations were performed by the HASS 8.4 computer program under license no. 38030713 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.062 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 22.6 ft/sec at pipe 14. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 9/24/2014BS\HYDRAULIC CALCULATION\TVFR #51\TVFR 51 .10-NEW AREA.SDF JOB TITLE: TVFR 51 .10-900 new area (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) PIPE FITTINGS TABLE Pipe Table Name: VIKINGFM.PIP PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T F B G C A D U Ell Tee 45e11 Bfyvlv Gatvlv Chkvlv Almvlv Dryvlv Udelug V R Viccup Runtee 1.049 2.00 5.00 1.00 2.20 1.00 5.00 10.00 0.10 0.00 2.00 2.00 1.380 3.00 6.00 1.00 2.00 1.00 7.00 10.00 0.10 0.00 2.00 2.00 1.610 4.00 8.00 2.00 2.50 1.00 9.00 10.00 0.10 0.00 2.00 2.00 2.067 5.00 10.00 2.00 8.00 1.00 10.00 10.00 0.10 18.00 2.00 2.00 PAGE: B MATERIAL: SCH10 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T F B G C A D U Ell Tee 45e11 Bfyvlv Gatvlv Chkvlv Almvlv Dryvlv Udelug V R Viccup Runtee 3.260 5.00 13.00 2.60 5.00 1.00 10.00 10.00 1.60 29.00 2.00 2.00 PAGE: D MATERIAL: DUCTL HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T F G C Ell Tee 45E11 Gatvlv Chkvlv 4.100 11.00 27.00 6.00 2.00 10.00 6.280 16.00 40.00 10.00 3.00 11.00 WATER SUPPLY ANALYSIS o ?:, Static: 104 . 00 psi Resid: 92. 00 psi Flow: 1610. 0 CO H 120. 0 9Pm H m w: 0. 0 H H ip 1 E�aDlable pressure � r\v 103.69 psi @ 243.2 gpm III H N 2 Required Q pressure or 100. 0 88.81 psi @ 243.2 gpm X) CO G A. Source Supply Curve Cl) A B. System Demand Curve x U C. Available at Source 1-' O to G . •• i : :U ms E 80 . 0 ` s - ootx r P E yn x R r w a C) k E n c Cl) I'D r H S °i y 3 S 60. 0 o x U z o R H > E C H 40 . 0 > z p c r s Cl) i ~ Cn (n N N 20. 0 O z xi 0 . 0 av Po• �4 a tn a m ro rn -14 . 7 00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 9/24/2014BS\HYDRAULIC CALCULATION\TVFR #51\TVFR 51 .10-NEW AREA.SDF JOB TITLE: TVFR 51 .10-900 new area WATER SUPPLY CURVE 108+ *0\\\\\\\ I \\\\\\\\\ 99+ \\\\\\\\\ I \\\\\\\\\ I \\\\\\\\ 92.0 psi @ 1610 gpm-> * 90+ Flow Test Point Ix 81+ 1 1 1 P 72+ R 1 E 1 S 1 S 63+ U I R 1 E I 54+ ( 1 P I S 1 I 45+ 36+ 1 1 27+ 1 1 1 18+ LEGEND It 1 X = Required Water Supply " 1 88.81 psi @ 243.2 gpm 9+ 1 0 = Available Water Supply " I 103.64 psi @ 243.2 gpm " " 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) HYDRAULIC CALCULATION SUMMARY SHEET ***TVFR #51 .10-900*** PROJECT NAME:--> TVFR #51 PROJECT ADDRESS:--> 8935 SW Burnham st. DRAWING SHEET NUMBER:--> FP2.1 DATE CALCULATED:--> 9/23/2014 AUTHORITY HAVING JURISDICTION:--> City Of Tigard SYSTEM INFORMATION: Size Of System: > 10,512 sq. ft. +/- Type Of System: > Wet Vol. Of Dry/Preaction/Anti-freeze Syetem: > N/A gallons Available Pressure > 103.5 psi Required Pressure > 58.6 psi Safety Factor > 44.9 psi / 43% DESIGN DATA: Remote Area Number: > #2 Remote Area Location: > Dayroom/Kitchem pR Occupancy Classification: > Light/Ordinary i�F.0 UFFS, Storage Commodity Classification: > N/A (f"�1Cs�MF^ * U91. Storage Height: > N/A :i :/ Density: > .10 gpm/sq. ft. � i Area Of Application: > 900 sq. ft. II-3i Coverage Per Sprinkler: > 225 sq. ft. max. OREGON+ Type Of Sprinkler Calculated: > Q.R. SSU VK302 • "-tY2Q,' ' Sprinkler K-Factor: > 5.6K � M L Number Of Sprinklers Calculated: > 9 IQ 42114 In-Rack Sprinkler Demand: > N/A Number Of In-Rack Sprinklers Calculated: > N/A Hose Streams Inside + Outside: > 100 gpm Total Water Required (including hose) : > 280.1 Flow And Pressure At Base Of Riser: > 180.1 gpm @ 56.4 psi WATER SUPPLY: Static psi:---> 104 Residual psi:--> 92 Flowing GPM:--> 1610.0 GPM @ 20 psi:--> 12,112 Test Date:----> 9/18/2014 Location: > NE corner of Fire Station Info From: > City of Tigard Water Dept PUMP INFO: Pump Type:--> N/A PSI Rating:--> N/A GPM Rating:--> N/A INSTALLING CONTRACTOR: Name: > Viking Automatic Sprinkler Co. Address: > 3245 NW Front Avenue, Portland, OR 97210-1509 Phone: > (503) 227-1171 Fax:--> (503) 227-1552 Designer: > Dave Bateman Oregon CCB#: > 64837 Washington Lic.#:--> VI-KI-NA-5373NT Calculations performed by HASS 8.4 under license # 38030713 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 9/23/2014NI JOBS\HYDRAULIC CALCULATION\TVFR #51\TVFR #51 .1-900.SDF JOB TITLE: TVFR #51 .1-900 WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 104.0 92.0 1610.0 103.5 280.1 58.6 Required pressure is 44.9 psi (43%) less than available pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 280.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 180.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 10 8.5 K= 5.60 31.1 31.2 11 8.5 K= 5.60 11.7 19.2 12 8.5 K= 5.60 12.1 19.5 13 8.5 K= 5.60 15.1 21.7 14 8.5 K= 5.60 8.5 16.3 15 8.5 K= 5.60 9.2 17.0 16 8.5 K= 5.60 8.9 16.7 17 8.5 K= 5.60 10.6 18.2 18 8.5 K= 5.60 13.2 20.3 1B 12.3 - - - - 34.0 - - - 2B 12.3 - - - - 13.7 - - - 3B 12.3 - - - - 14.1 - - - 4B 12.3 - - - - 16.2 - - - 5B 12.3 - - - - 10.1 - - - 6B 12.3 - - - - 10.3 - - - 7B 12.3 - - - - 10.6 - - - 8B 12.3 - - - - 12.5 - - - 9B 12.3 - - - - 16.0 - - - B1 10.7 - - - - 24.6 - - - B2 10.7 - - - - 21.6 - - - M3 10.7 - - - - 35.3 - - - M6 11.3 - - - - 36.7 - - - M7 11.3 - - - - 44.1 - - - TOR 11.3 - - - - 44.3 - - - BF1 2.5 - - - - 55.6 - - - BF2 2.5 - - - - 48.6 - - - BOR 0.8 - - - - 56.4 - - - SRC -4.0 SOURCE 58.6 180.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 9/23/2014NI JOBS\HYDRAULIC CALCULATION\TVFR #51\TVFR #51 .1-900.SDF JOB TITLE: TVFR #51 .1-900 PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -31.2 1.049 PL 8.17 PF 4.5 10 8.5 5.6 31.1 31.2 11.6 120 FTG ET PE -1.7 113 12.3 0.0 34.0 0.0 0.297 TL 15.17 PV Pipe: 2 -19.2 1.049 PL 23.00 PF 3.6 11 8.5 5.6 11.7 19.2 7.1 120 FTG ET PE -1.7 2B 12.3 0.0 13.7 0.0 0.121 TL 30.00 PV Pipe: 3 -19.5 1.049 PL 23.00 PF 3.7 12 8.5 5.6 12.1 19.5 7.2 120 FTG ET PE -1.7 3B 12.3 0.0 14.1 0.0 0.124 TL 30.00 PV Pipe: 4 -21.7 1.049 PL 9.00 PF 2.7 13 8.5 5.6 15.1 21.7 8.1 120 FTG 2ET PE -1.7 4B 12.3 0.0 16.2 0.0 0.152 TL 18.00 PV Pipe: 5 -16.3 1.049 PL 26.17 PF 3.3 14 8.5 5.6 8.5 16.3 6.0 120 FTG 3ET PE -1.7 5B 12.3 0.0 10.1 0.0 0.089 TL 37.17 PV Pipe: 6 -17.0 1.049 PL 23.50 PF 3.1 15 8.5 5.6 9.2 17.0 6.3 120 FTG 2ET PE -1.7 7B 12.3 0.0 10.6 0.0 0.096 TL 32.50 PV Pipe: 7 -16.7 1.049 PL 24.00 PF 3.1 16 8.5 5.6 8.9 16.7 6.2 120 FTG 2ET PE -1.7 6B 12.3 0.0 10.3 0.0 0.093 TL 33.00 PV Pipe: 8 -18.2 1.049 PL 24.00 PF 3.6 17 8.5 5.6 10.6 18.2 6.8 120 FTG 2ET PE -1.7 8B 12.3 0.0 12.5 0.0 0.109 TL 33.00 PV Pipe: 9 -20.3 1.049 PL 24.00 PF 4.4 18 8.5 5.6 13.2 20.3 7.6 120 FTG 2ET PE -1.7 9B 12.3 0.0 16.0 0.0 0.134 TL 33.00 PV Pipe: 10 -31.2 1.610 PL 5.75 PF 0.7 1B 12.3 0.0 34.0 0.0 4.9 120 FTG ET PE 0.7 M3 10.7 0.0 35.3 0.0 0.037 TL 17.75 PV Pipe: 11 -31.2 1.610 PL 28.33 PF 1.6 M3 10.7 0.0 35.3 0.0 4.9 120 FTG 2ET PE -0.3 M6 11.3 0.0 36.7 0.0 0.037 TL 44.33 PV Pipe: 12 -19.2 1.380 PL 14.00 PF 0.4 2B 12.3 0.0 13.7 0.0 4.1 120 FTG ---- PE 0.0 3B 12.3 0.0 14.1 0.0 0.032 TL 14.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 9/23/2014NI JOBS\HYDRAULIC CALCULATION\TVFR #51\TVFR #51 .1-900.SDF JOB TITLE: TVFR #51 .1-900 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -38.7 1.380 PL 17.42 PF 2.0 3B 12.3 0.0 14.1 0.0 8.3 120 FTG ---- PE 0.0 4B 12.3 0.0 16.2 0.0 0.116 TL 17.42 PV Pipe: 14 -60.4 1.380 PL 5.75 PF 4.7 4B 12.3 0.0 16.2 0.0 13.0 120 FTG 2T PE 0.7 B2 10.7 0.0 21.6 0.0 0.264 TL 17.75 PV Pipe: 15 -16.3 1.380 PL 7.00 PF 0.2 5B 12.3 0.0 10.1 0.0 3.5 120 FTG ---- PE 0.0 6B 12.3 0.0 10.3 0.0 0.023 TL 7.00 PV Pipe: 16 -33.0 1.380 PL 4.33 PF 0.4 6B 12.3 0.0 10.3 0.0 7.1 120 FTG ---- PE 0.0 7B 12.3 0.0 10.6 0.0 0.086 TL 4.33 PV Pipe: 17 -49.9 1.380 PL 10.00 PF 1.9 7B 12.3 0.0 10.6 0.0 10.7 120 FTG ---- PE 0.0 8B 12.3 0.0 12.5 0.0 0.186 TL 10.00 PV Pipe: 18 -68.1 1.380 PL 10.50 PF 3.5 8B 12.3 0.0 12.5 0.0 14.6 120 FTG ---- PE 0.0 9B 12.3 0.0 16.0 0.0 0.330 TL 10.50 PV Pipe: 19 -88.5 1.380 PL 2.67 PF 7.9 9B 12.3 0.0 16.0 0.0 19.0 120 FTG 2T PE 0.7 B1 10.7 0.0 24.6 0.0 0.536 TL 14.67 PV Pipe: 20 -60.4 1.380 PL 11.25 PF 3.0 B2 10.7 0.0 21.6 0.0 13.0 120 FTG ---- PE 0.0 B1 10.7 0.0 24.6 0.0 0.264 TL 11.25 PV Pipe: 21 -148.9 1.610 PL 10.75 PF 12.4 B1 10.7 0.0 24.6 0.0 23.5 120 FTG 2E PE -0.3 M6 11.3 0.0 36.7 0.0 0.662 TL 18.75 PV Pipe: 22 -180.1 2.067 PL 16.58 PF 7.4 M6 11.3 0.0 36.7 0.0 17.2 120 FTG T PE 0.0 M7 11.3 0.0 44.1 0.0 0.279 TL 26.58 PV Pipe: 23 -180.1 3.260 PL 4.62 PF 0.1 M7 11.3 0.0 44.1 0.0 6.9 120 FTG ---- PE 0.0 TOR 11.3 0.0 44.3 0.0 0.030 TL 4.62 PV Pipe: 24 -180.1 3.260 PL 8.83 PF 0.6 TOR 11.3 0.0 44.3 0.0 6.9 120 FTG 2E PE 3.8 BF2 2.5 0.0 48.6 0.0 0.030 TL 18.83 PV Pipe: 25 FIXED PRESSURE LOSS DEVICE BF1 2.5 0.0 55.6 0.0 7.0 psi, 180.1 gpm BF2 2.5 0.0 48.6 0.0 i SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page DATE: 9/23/2014NI JOBS\HYDRAULIC CALCULATION\TVFR #51\TVFR #51 .1-900.SDF5 JOB TITLE: TVFR #51 .1-900 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) NODES (FT) (K) (PSI) (GPM) (FT) P FL/FT (PSI) Pipe: 26 -180.1 4 .260 PL 1.75 PF 0.0 BF1 2.5 0.0 55.6 0.0 4. 1 120 FTG BOR 0.8 0.0 56.4 0.0 5 PE 0.7 0.008 TL 1.75 PV Pipe: 27 -180.1 6.280 PL 80.00 PF 0.1 BOR 0.8 0.0 56.4 0.0 1.9 140 FTG ET PE 2. 1 SRC -4.0 SRCE 58.6 (N/A) 0.001 TL 136.00 PV NOTES (HASS) : (1) Calculations were performed by the HASS 8.4 computer program under license no. 38030713 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.057 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 23.5 ft/sec at pipe 21. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) PIPE FITTINGS TABLE Pipe Table Name: VIKINGFM.PIP PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T F B G C A D U Ell Tee 45e1l Bfyvlv Gatvlv Chkvlv Almvlv Dryvlv Udelug V R Viccup Runtee 1.049 2.00 5.00 1.00 2.20 1.00 5.00 10.00 0.10 0.00 2.00 2.00 1.380 3.00 6.00 1.00 2.00 1.00 7.00 10.00 0.10 0.00 2.00 2.00 1.610 4.00 8.00 2.00 2.50 1.00 9.00 10.00 0.10 0.00 2.00 2.00 2.067 5.00 10.00 2.00 8.00 1.00 10.00 10.00 0. 10 18.00 2.00 2.00 L SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 9/23/2014NI JOBS\HYDRAULIC CALCULATION\TVFR #51\TVFR #51 .1-900.SDF JOB TITLE: TVFR #51 .1-900 PAGE: B MATERIAL: SCH10 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T F B G C A D U Ell Tee 45e11 Bfyvlv Gatvlv Chkvlv Almvlv Dryvlv Udelug V R Viccup Runtee 3.260 5.00 13.00 2.60 5.00 1.00 10.00 10.00 1.60 29.00 2.00 2.00 4.260 6.80 16.00 3.40 12.00 2.00 13.00 13.00 5.90 35.00 2.00 2.00 PAGE: D MATERIAL: DUCTL HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T F G C Ell Tee 45E11 Gatvlv Chkvlv 6.280 16.00 40.00 10.00 3.00 11.00 WATER SUPPLY ANALYSIS o - 120. 0 Static: 104 . 00 psi Resid: 92 . 00 psi Flow: 1610 . 0 gpm ,..3 . I-I LEGEND y 1 r � Available pressure .. N 103.53 psi @ 280.1 gpm I H N < o 100 . 0 — 2 Required pressure G 58.60 psi @ 280.1 gpm 4u H A A. Source Supply Curve ul B. System Demand Curve o U w v, .� C. Available at Source ~' CA Pt) ..■...■ E ._..........••... 0 K Z G 80. 0 ` o o r ', r4 P c x r R I-1 1!1 n K E n .3 S 60 . 0 ' S U • x > o R E z r • H 1-3 H () 40. 0 m z p / H # r in s K N w i H cn 20. 0 z cr. 1- 1 LED 0 0 . 0 o ro • a r m M -14 . 7 ∎ bi . 61 : 11 611 11 • 11 .11 : 11 600 SPRINKLER HYDRAULIC DATE: 9/23/2014NI JOBS\HYDRAULIC SYSTEM CALCULATION\TVFRA Page 8 #51\TVFR #51 .1-900.SDF JOB TITLE: TVFR #51 .1-900 WATER SUPPLY CURVE 108+ f *\0\\\\\\ 1 \\\\\\\\\ 99+ \\\\\\\\\ I \\\\\\\\\ 1 \\\\\\\\ I 92.0 90+ psi @ 1610 gpm-> Flow Test Point I I I 81+ 1 1 1 P 72+ R I E I S I S 63+ U I R I X E I 54+ ( I P S I I 45+ I 1 I 36+ I I I 27+ I I 1 18+ LEGEND I " I X = Required Water Supply " I 58.60 psi @ 280.1 gpm /I 9+ „ I 0 = Available Water Supply " I 103.53 psi @ 280.1 gpm " I I1 0++ +---.4- -f- + + + + + 400 600 800 1000 1200 1400 1600 1800 + 2000 FLOW (GPM) Tol-Brace Seismic Calculations Viking Sprinkler Project Address: TVFR#51 3245 nw Front Ave B-Line 8935 sw Burnham St Portland Or 97210 503-227-1171 by E_T•N Tigard,OR 97223 OR:64837 WA:VIKINAS-3737 Job#OpC 4894 Calculations based on 2010 NFPA Pamphlet#13 Brace Information Tolco Brace Components Maximum Spacing 9'0"(2.74 m) Tolco Component Fig. Number Adjusted Load Maximum Brace Length 7'0"(2.13 m) Fig.4LA(Lat)Clamp 707 lbs(321 kg) Bracing Material 1"Sch.40 Fig.980 Universal Swivel 1955 lbs(887 kg) Angle from Vertical 45°Min. 'Calculation Based on CONCENTRIC Loading 'Please Note:These calculations are for Tolco components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42"(11 mm) Assembly Detail L/R Value 200 1310 lbs(594 k 6 -E,VEL&A SWAY Max Horizontal Load ( 9) urAVC"sALMENT BRACE ATTACHMENT __-_ Force Factor(Cp) 0.51 'O SPACE PIPE 'I Fastener Information 6-UNE I TOLCO FIG ALA NFPA T e B E ATTACHMENT Fastener Orientation GRACEAtt-•CIP) MaximumLoad 260 lbs(118 kg) Diameter 1/tin.(13 mm) , Length 3-1/2in.(89 mm) FIG ALA M ALA It.-iIE61 iY•i NA Type Dual Lag Bolts-Fig.906 Brace Identification on Plans #101 LATERAL Orientation of Brace Lateral Braced Pipe:1.5"Sch.10 Steel Pipe Load INformation Size and Type of Pipe Total Length Total CalculatedLoad 1.5"Sch.10 Steel Pipe(38.1 mm) 9ft(2.7 m) 14 lbs(6 kg) 1.25"Sch.10 Steel Pipe(31.75 mm) 10ft(3 m) 13 lbs(6 kg) 1"Sch.10 Steel Pipe(25.4 mm) 108ft(32.9 m) 100 lbs(45 kg) Percentage added for Fittings and Sprinklers 15% 19 lbs(8.62 kg) Total Adjusted Load of all pipe within Zone of Influence 145 lbs(66 kg) frol-Brace Verizon 71 Tol-Brace Seismic Calculations TVFR#51 Job#opc4894 B-Line 8935 sw Burnham St Brace Identification #101 LATERAL by E.T•N Brace Type(Per NFPA#13) NFPA Type B Braced Pipe 1.5"Sch.10 Steel Pipe Spacing of Brace 9'0"(2.74 m) Orientation of Brace Lateral Bracing Material 1"Sch.40 Maximum Brace Length 7'0"(2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 1/2 x 3-1/2(13 x 89 mm)Dual Lag Bolts Parallel to Beam-TOLCO Fig 9 Length of Fastener 3-1/2in.(89 mm) Summary of Pipe within Zone of Influence 1.5"Sch.10 Steel Pipe(38.1 mm) 91t(2.7 m) 1.25"Sch.10 Steel Pipe(31.75 mm) 10ft(3 m) r Sch.10 Steel Pipe(25.4 mm) 108ft(32.9 m) G-Factor Used 0.51 Allowance for Heads and Fittings 15% Conclusions (1,0 PRCFTotal Adjusted Load of Pipe in Zone of Influence 145 Ibs(66 kg) JGIfVF �, Material Capacity 1310 Ibs(594 kg) dyy .Fastener Capacity 260 Ibs(118 kg)Fig.4LA(Lat)Clamp 707 Ibs(321 kg) REGQ,��'3f Fig.980 Universal Swivel 1955 lbs(887 kg) uttP Structural Member WOOD JOIST 4A/ M " Calculations prepared by Bateman /0 ozi 14 The description of the Structural Member is for informational purposes only. Tol-Brace software calculates the brace assembly only,not the structure it is attached to. Calculated with Tol-Brace 7 Visit us at www.tolco.com Tol-Brace Seismic Calculations Project Address: TvFR#51 Viking Sprinkler - 3245 nw Front Ave B-Line 8935 sw Burnham St Portland Or 97210 503-227-1171 by . ! e Tigard,OR 97223 OR:64837 WA:VIKINAS-3737 by Job#opc 4894 Calculations based on 2010 NFPA Pamphlet#13 Brace Information Tolco Brace Components Maximum Spacing 9'0"(2.74 m) Tolco Component Fig. Number Adjusted Load Maximum Brace Length 7'0"(2.13 m) Fig.4LA(Long)Clamp 707 lbs(321 kg) Bracing Material 1"Sch.40 Fig.980 Universal Swivel 1955 lbs(887 kg) Angle from Vertical 45°Min. 'Calculation Based on CONCENTRIC Loading 'Please Note:These calculations are for Tolco components only.Use of any Least Rad.of Gyration 0.42"(11 mm) other components voids these calculations and the listing of the assembly. L/R Value 200 Assembly Detail Max Horizontal Load 1310 lbs(594 kg) " 17pCp�M _.. Force Factor(Cp) 0.51 we��trr�prr . ."1C.r.. • Fastener Information Fastener Orientation NFPA Type H MaximumLoad 360 lbs (163 kg) Z1V Diameter 1/2in.(13 mm) i, Q PO ALA Length 3-1/2in. (89 mm) . " Type Dual Lag Bolts-Fig.906 Brace Identification on Plans #201 LONGITUDINAL Orientation of Brace Longitudinal Braced Pipe: 1.5"Sch.10 Steel Pipe Load INformation Size and Type of Pipe Total Length Total CalculatedLoad 1.5"Sch.10 Steel Pipe(38.1 mm) 9ft(2.7 m) 14 lbs(6 kg) 1.25"Sch.10 Steel Pipe(31.75 mm) 1Oft(3 m) 13 lbs(6 kg) 1"Sch.10 Steel Pipe(25.4 mm) 108ft(32.9 m) 100 lbs(45 kg) IPercentage added for Fittings and Sprinklers 5% 1 1 19 lbs(8.62 kg) Total Adjusted Load of all pipe within Zone of Influence 145 lbs(66 kg) iTol-Brace Verizon 71 Tol-Brace Seismic Calculations TVFR#51 Job#opc 4894 8935 sw Burnham St B Li ne Brace Identification #201 LONGITUDINAL by E=T•N Brace Type(Per NFPA#13) NFPA Type H Braced Pipe 1.5"Sch.10 Steel Pipe Spacing of Brace 9'0"(2.74 m) Orientation of Brace Longitudinal Bracing Material 1"Sch.40 Maximum Brace Length 7'0"(2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 1/2 x 3-1/2(13 x 89 mm) Dual Lag Bolts Perpendicular to Beam-TOLCI Length of Fastener 3-1/2in.(89 mm) Summary of Pipe within Zone of Influence 1.5"Sch.10 Steel Pipe(38.1 mm) 98(2.7 m) 1.25"Sch.10 Steel Pipe(31.75 mm) 1108(3 m) 1"Sch.10 Steel Pipe(25.4 mm) 1088(32.9 m) G-Factor Used 0.51 Allowance for Heads and Fittings 15% Conclusions �F.d F ��'`��Gli+�c ,s�0 Total Adjusted Load of Pipe in Zone of Influence 145 lbs(66 kg) e t • y Material Capacity 1310 lbs(594 kg) / r Fastener Capacity 360 lbs(163 kg) 12-31 OREGON Fig.4LA(Long)Clam 707 lbs(321 kg) . y a, Fig.980 Universal Swivel 1955 lbs(887 kg) ��1 M L � Structural Member WOOD JOISTS \ /O OZ/ (4 Calculations prepared by Bateman 'The description of the Structural Member is for informational purposes only. Tol-Brace software calculates the brace assembly only,not the structure it is attached to Calculated with Tol-Brace 7 Visit us at www.tolco.com