Loading...
Plans BUP2013 - 00113 r ti V MENT WORK FOR ennet i ar LL, Architecture MAY 9 2013 Urban Planning IA Store Design 360 Lexington Avenue CITY OF TI Mixed-Use New.York,NY10017 BUILDING DIVISO Retail Development www.kennethpark.com MEP Consultant c< � don penn a consulting engineer 635 Westport Parkway Suite 300 Grapevine,Texas 76051 CITY OF TIGARD Phone:817-410-2858 Fax:817-251-8411 Approved.........i 7......**04anowma.a r Conditionally Approved..........""[ j See Letter to:Follow. SEAL: ..R...a.a......s. Attached................[ j I HEREBY CERTIFY THAT THIS DRAWING Permit Number:FWPZ& ,�t,a WAS PREPARED BY ME OR UNDER MY BOUTIQUE # 057Address: �2'�-�Q3 I �' DIRECT SUPERVISION AND THAT I AM A By:•�.. Date: DULY REGISTERED/LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF Approved plansOREGON shall be on job site. ARCHITECTURAL REG. ##: 3721 REGISTRATION EXPIRES : 6/30/2013 OFFICE COPS _ : . t; Al?o DEFERRED 1(31 PAM 585 SW WASHIN �`tr�SPrtnl�i � Q ,9 RD . .. Fire Atum ;K 0 o f' ti mechante Pfumbin TIGAR OR 97223 Etcctr[ca! � �* Tmss Engineertn ., Shop Drawings ON Other SAY 0 2 2013 STORE LOCATION: WASHINGTON SQUARE MALL LIGHTING FIXTURES TBD OWNER L'OCCITANE THE WORK DELINEATED IN THESE DRAWINGS AND DESCRIBED IN THE ARCHITECTURAL 9585 SW WASHINGTON SQ. RD. 1430 BROADWAY,2ND FLOOR SPECIFICATION SHALL CONFORM TO ALL CODES AND STANDARDS THAT HAVE A000 COVER SHEET TIGARD, OR 97223 NOTE: PROVIDED BY JURISDICTION IN THE CITY OF TIGARD AND STATE OF OREGON. NEW YORK, NY 10018 ASOI ARCHITECTURAL SPECIFICATIONS OWNER/TENANT: L'OCCITANE L'OCCITANE, G.C.TO TEL: (646) 284-9256 1. ALL REQUIREMENTS AND REGULATIONS PERTAINING TO THE AS02 ARCHITECTURAL SPECIFICATIONS L A INSTAL S PER DWG'S 1430 BROADWAY, 2ND FLOOR FAX: (212) 213-0803 HANDICAPPED AND OSHA MUST BE INCORPORATED IN THE WORK EVEN AS03 ARCHITECTURAL SPECIFICATIONS - THOUGH THEY MAY NOT BE LISTED INDIVIDUALLY AND SEPARATELY IN NEW YORK, NY 10018 EITHER THE DRAWINGS OR SPECIFICATIONS. A001 ADA COMPLIANCE &STANDARDS A002 SCHEDULES � . 2. THESE GENERAL NOTES SHALL APPLY TO ALL DRAWINGS AND GOVERN A003 DOOR SCHEDULES "R UNLESS OTHERWISE NOTED OR SPECIFIED.'�nneCODE REVIEW INFORMATION: r 9 A004 PARTITION TYPES & FRAMING DETAILS „re'✓..�_: , ....is,�'.. y.:.......... .'Y .: .,i✓"✓,s{?,<,y?.,::f f:. ��, „� ..�.t�� ,�;.r:a ,f3 g...:w y4 m-n,✓ y.�., - r�' r, 'sr,., .': r'..: 3f. c..,.:0,5,7, .12,y k,i a.as:',bs,,,..,.7.b,f^'.Y? ?nui4 ,st4•>54:..r.!.,,.:5': ...:. <.s#,l,.5..,%t,,.:,..v?v :E:,��h:�r�3,:,,:'y;<.},._...<,.,i>,,<e,,`�<,,::. :.��`:. _.y. ..r,+,,.^.,>.r^':,. .....s:yr:y.,:>,r3,x.,r,:r,..>?•,,a�.:.s.l.>,::F>z':'<;s.v.:�v,..<;:>,x,.�sx6n<.`sf,„...<9^>c,':.:.,a�...,,.r/s<s,..:.,3:,=F�f<,.„(.:.>,i../.,<:_:,y�y..,:.,.,,..,:s.d<:�,.;...!,,,;.S..:5G..'�a.,,,<.!_�.y,/t:..,/<,�.:,(r./..,.�y.5..,.�y.r.(,..,p..,.,..s.�y"l_:..,s.;,,,r,;y�..a,:,,..h,,y��s.:n.,i,.�..'�;',�.a�ft.h.'."f:s.`,.�.,..,::.'.,..:ss�.fsr,s,.i:?..<,<`..,.2.;�.,s.�:.,.�.,:,,,,r.,��.-vM:E_,,r.�y,,..sA,,,.W.s...�:,,/rf,.x,,f,�,,.y,,as.sbr%,,s.,.a..r:.��<f.:/F,,.�,s.:r,::....4y.�,:,,K...,E,,:q...,.,,,�,S..f_,x,s.r:,r�,:,..,.�.,a,Y,„:�.9,,.x.y�,.,,::.�_f,'"�yy.,:d:�:_.:,.s.,Y,.s�,.�b',.:....,�,:.:,,•.:,.�rri,..rs..:.,.,,.s�.<.,.:�:.y„�,�x:,,,�....�„'.�r✓ A005 EGRESS SS &ACCESSIBILITY3. VERIFY ALL EXISTING DIMENSIONSS N CONDITIONSS AT THE JOB SITE05-02-13 I'. � �-,Y,:�:,.s,:.,::,,:,,.",,,,...«=.'<:,,.S..�:.;.;>.;,,�....z,a;�f.r,�<:,,�..,._ R>�'�7�s��. .f,..<�:,,.�y1_y�..7.y.,..b,.,.2<�,�:.,<.5'.�..y,..�..,._:�:�f:>.H.���.:,�y,a�,,b,,>�,.,.�.,�sa,5�.,.5.�.,�s:,,�k-.s..r,�,s�/�::.j�fx�,"x`-�r„K..>-�......':y w�.�,:;:.g`�.�„vss.�r<.,f./;,,ar....r�,:,``,,��,.:,,.�,r5fr6��,:g/,h�,.,,✓�x„.,c,f:�.�i!`,`,<„:sr,.,b4i.l,<;,,.,,,K��x:,,,.,,;r;.r,s,.,..ti,&:�ae�,':�.,�,..��;�:�,..f�,,rss:�,�;,��,f5.,,;r�.r.,li,..:,�<",,4,.>?<�s.'..:u,�,:,,.f�':',^v',5.s....x:,�;,.•:��:,,,�5,�.n.,.F,.,Y,.:.>issy.»<s..y,,'s,,r;,i,:�..,.���.vi,,�Y..�:.x...,y:.,,f..J�z��r:,y,.�..,v�,,.F';.f<.�<::.,rc:-.,,...isr,.yy,b�Y,:..z�,,��/.„,.,'�'y��.�ya,�.'",.;u,.<.��..s..,�'r,,,,:,,.�:.::,.�r,.r��.,,,,,.y:.�,.���,.�,�s,,.�.�.:.:e::,a,�f�'�,r:,..,,�,�,�k"➢,,,.f.�,,r'.,s:��..rt�;./i5::.r�'s,a..<<i.x..�.=':..a�':��� ISSUE FOR LANDLORD & PERMIT3APPLICABLE CODES ALL WORK DONE UNDER THIS CONTRACT SHALL l, AUDIOSY TEM MICHAEL TIN ON OWNER1s REP./ JAVIER ORTIZ PRIOR TO SUBMISSION OF BIDS.COMPARE ARCHITECTURAL DRAWINGS A006 LANDLORD NOTES COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, DRAWINGS DMX CONSTRUCTION PM. WITH MECHANICAL AND ELECTRICAL DRAWINGS AND REPORT ANYPROJECT MANAGERCONSTRUCTI N CRITERIA OF THE LANDLORD, AND SHALL SATISFY ALL D100 DEMOLITION PLAN O4-19- 13 PRELIM PACKAGE ISSUEDISCREPANCIES TO THE ARCHITECTS.NO INFORMATION OR DETAIL N NOTE. PROVIDED BY 1703 W. FIFTH STREET SUITE 600 L'OCCITANE x APPLICABLE CODES ORDINANCES AND REGULATIONS F A A100 BARRI ADE DETAIL �.w^v ...: '. .i^,, 9'¢h��.� 3;-;lss�r,� ..�.���yl/'!%.'s��gys,�ry��1£0 �"`r'q �✓fi/ra xx51:.,5.� .(%i. ;: � , O S O ALL , ;� THE DRAWINGS OF THIS PROJECT MAY BE USED WITHOUT THE WRITTEN C S .:.::x f,3..� s.: <' .,�y4r„ r ...::. .v.. L OCCITANE G.C.TO AUSTIN TX 78703 s a: 1430 BROADWAY 2ND FLOOR -sc..,rc.•.: <. y.,:. r..y?f..,x. ::., : z y D. .'F."'a"✓:rfs.4'Ya?,fH:y,„/:y`ff5. �' .':dr' >3. ::,3'F,Nr� GOVERNING BODIES INVOLVED. ANY , PERMISSION ,, MODIFICATIONS TO THE CONTRACTOF THE ARCHITECTS. A 1 Ol NEW WORK PLAN RUN SPEAKER WIRE TEL. 512 380-8561 D DATE REVISIONS _..ya` .4i .< v$ %r✓'�M ..yvy,.yyy'S✓y'r,yhj,`r, x , r� shx-,9€ ( ) h;r.. sMr., x� fh , f�«nd `,<7; WORK REQUIRED BY SUCH AUTHORITIES SHALL BE PERFORMED BY THE NEW YORK, NY 10018 y ;� y' f w �:w ya% A102 REFLECTED CEILING PLAN y, FROM CONTROLS AT FAX: (XXX) XXX-XXXX 4. DO NOT SCALE DRAWINGS!!! z F TENANTS CONTRACTOR.ALL PERMITS AND LICENSES NECESSARY FOR THE TEL: (646) 284-9221 v 3" • 5 u :;xfn,'x r A103 POWER PLAN ROOM TO EMAIL: michael.stinson@dmx.com KEY.x.PLAN: EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE FAX (212) 213-0803 s .�...y;,,„..2:>'� ': s : .,�r„„n.y;,sr.`>�. ? �. ,./5...,,s.:1.."✓r.:�.v,s:.>;,. -..: ...,.�,f4,.,",,,,,: rhy,y4....,.0...:.::• 0803j SPEAKERS REFER TO TENANT S CONTRACTOR(S). APPLICABLE CODES INCLUDE. BUT ARE NOT A104 FIXTURE PLAN5. UNLESS OTHERWISE SHOWNWN R NOTED,ALL TYPICAL SHALL BE .;. /... .w, n ,ubH. , EMAIL. 1ortiz@us.loccitane.com USED WHERE APPLICABLE. ELECTRICAL FOR DETAILS A105 FIXTURE SCHEDULE ..,. .>. 'i i s<sya:s✓%.n-�.a:;:1':::v;r,ss.,l:;:s.Yr,avb;.,>`r.-`r b<.-..t,<5..F''.,r,?�sr, n....sr".;j,.<,;:y:�F/xr">4>rrk,.:,:.�;fri,yi�'.:,ti..s..,>,,;s;3,gg_.5..<;'�..,.>.Y~..->Y-.,.,;.�.�...>,.,s..:.:,:_.,,F>�ixi�:�.i:��,.<Y�r.�;.:)�•'%.r.�64:..."a,.>,.�.a._.:_b_/-::��S.;,I,Y..��.:?..,.,,a,:,::�c�>s:_:..,h�.::� Sn^,_�_,�.,. . :=:.¢L,rY:.-!.f'�,iby`�..,....y;�::,..E5:.,.':Y.4.,a%,N�.T:y_s3.,. �yi sy�::'r.',1:J,,�10:?,�/r:`_',R�.:b��.':vi_;..Sy,,,ir:,,;;,�v,f LIMITED TO THE FOLLOWING: IN A 1 Ob FINISH PLAN y' ?v 2 6. ALL DETAILS SHALL BE CONSIDERED TYPICAL AT SIMILAR CONDITIONS. My . 7. SAFETY MEASURES. AT ALL TIMES THE CONTRACTOR SHALL BE SOLELYSTOREFRONT SIGNAGE TBD LANDL RD AAR N PRATT , A201 SALES AREA ELEVATIONSA200 SALES AREA ELEVATIONS ,. MGR.TENANT COORDINATION AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE f . NORDSTROM A A� THE NOTE: PROVIDED BY 202 BACK OF HOUSE ELEVATIONS SAFETY OF THE PERSONS&PROPERTY AND FOR ALL � G MACERICH y.,5 4,k;.,Y.s.::F.':-.�..'d✓.:�.;., �'�r4(.'.:t r;,:�r.�u...FY�„,�✓4,::.'3:,3...'�<:.r:.+;9:b: ✓x. ,..£�. ... :s,fir..,5;,.:."..b..,.',:.�..:,;r,,..,�fi..>e,„:,:a._�,..9.s.rY�:_,,,�..;<�.F>::)..,,i:t�✓��m,.....,,...�.,,�...<',ryf.b�i7f.fGjr.,,�.�v.,.,.s,��>.£,�.�,a3�.,::.(:.�..,,._r,,.a�y...',a,.,,.�:.�s,�,.,,Is,.�,,l9:.Jao:f..><.,....,.a�,.. ,..�.3:..;��,,y.,_A,..,..,.,<.,,,;f�.,'yY�..._,:...�....:...._M.,�_.,,..�.�r:,.:'>_:i_.-.::,.,.;.,_�.�.::�...'a,,n.�....y,:�":�,..�.,>.,",,._Y..Y,�.r.r 9..n�,.f,.�":..:._,��a,<'..5s_.;::_.�.v.r...i...,...,..},..,,.,._��.,',,..r.y,,,,�k,:,s.�:r�.y.�<£„.r.'rs,.s,,�:,.,s.d<,�>..,:.�<.,r,�,:firw,,�s�ib2,,:x,�, INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS.THE A300STOREFRONTPLA N & ELEVATION L'OCCITANE VENDOR1141 N. ATUM BLVD ARCHITECTS OR ENGINEER'S JOBSITE REVIEW IS NOT INTENDED TO A400 CEILING DETAILS BUILDING AND STRUCTURAL: 2010 OREGON STRUCTURAL SPECIALTY CODE G.C.TO COORDINATE& .N ...�._,. .,...: . ..,..;.,,. .5 PHOENIX, AZ 85028 INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTORS SAFETY INSTALL AS PER DWG'S A401 FIXTURE DETAILS ( ) MEASURES. F Er£ ' s Y : f ✓b TEL: 602 953-6750 bi L'OCCITANE, MECHANICAL: 2010 OREGON MECHANICAL SPECIALTY CODE A402 FIXTURE DETAILSx "" 1 E-MAIL: aaron.pratt@macerich.com r F, :.w t.. ,� , T , , SUITE #H6 8. CONSTRUCTION WORK WILL NOT BLOCK HALLWAYS OF MEANS OF RD' xis PLUMBING: 2011 OREGON PLUMBING SPECIALTY CODE EGRESS. MECHANICAL ELECTRICAL: 201 1 OREGON ELECTRICAL SPECIALTY CODE 9. CONTRACTOR SHALL REFER TO GENERAL NOTES AS DESCRIBED ON EACH M100 MECHANICAL PLAN L'OCCITANE TB A D DRAWING SHEET AND INCORPORATE AS A PART OF THIS SCOPE OF STORAGE SHELVING D ARCHITECT ARIAN OUSO WORK. M200 MECHANICAL DETAILS &SPECIFICATIONS SPACE #H6 FIRE: 2007 PORTLAND FIRE CODE KENNETH PARK ARCHITECTS M300 MECHANICAL SPECIFICATIONS LOCATION MAP 7NOTE: PROVIDED BY 360 LEXINGTON AVENUE, 7TH FLOOR 10. ABSOLUTELY NO SUBSTITUTIONS WILL BE ALLOWED,UNLESS APPROVED BY LOCATION: ENERGY: 2010 OREGON ENERGY EFFICIENCY SPECIALTY L'OCCITANE VENDOR, THE ARCHITECT IN WRITING. NEW YORK, NY 10017 ELECTRICAL CODE G.C.TO COORDINATE& TEL: (212) 599 0044 EXT.238 11. G.C.SHALL FURNISH ONE EMPTY DUMPSTER AT STORE TURNOVER TO E100 LIGHTING PLAN NTS INSTALL AS PER DWG'S. FAX: (212) 599 0066 OWNER FOR STORE'S DISPOSAL OF CARDBOARDS,TRASH,ETC. 1. BUILDING DEPT: CITY OF TIGARD-BUILDING DEPARTMENT REFER TO FIXTURE PLAN E-MAIL: adouso@kennethpark.com E200 POWER PLAN 1312 SW HALL BLVD. FOR DETAILS 12. HAZARDOUS SUBSTANCES:IT IS THE RESPONSIBILITY OF THE TENANT AND E300 ELECTRICAL SPECIFICATIONS, PANELS & RISER TIGARD, OR 97223 THE TENANT'S CONTRACTOR(S),WHEN PREPARING FOR AND E400 ELECTRICAL SPECIFICATIONS EN PROVENCEPROCEEDING WITH CONSTRUCTION IN THE PREMESIS TO COMPLY WITH TEL: (503) 639-4171 ALL REQUIREMENTS OF ALL APPLICABLE Q C BLE LAWS CONCERNING HAZARDOUS BOUTIQUE #057 LOW VOLTAGE/DATA/ SARAH K. LATHERS M.E.P. ELIZABETH VENEGAS SUBSTANCES.THE TENANT SHALL NOT PERMIT THE INSTALLATION OR USE OF SPRINKLER ANY HAZARDOUS SUBSTANCES IN ANY COMPONENT OF THE PREMISES WASHINGTON SQUARE MALL 2. BUILDING DATA: TELECOM SYSTEM ACCOUNT MANAGER PROJECT MANAGER DURING ITS TENANCY. F100 FIRE PROTECTION PLAN - INTEGRA SERVICE GROUP DON PENN CONSULTING ENGINEER SPACE #H6 - A. CONST. CLASSIFICATION: TYPE IIB NOTE. G.C.TO RUN 318 BROADWAY 635 WESTPORT PARKWAY,SUITE 300 9585 SW WASHINGTON SQ. RD. B. OCCUPANCY CLASS: MERCANTILE LINES, TERMINATION SCHENECTADY, NY 12305 GRAPEVINE, TX 76051 Q TIGARD, OR 97223 C. SPRINKLER SYSTEM: FULLY SPRINKLERED PROVIDED BY VOICEMAIL:(518) 346-0250 X-16 TEL: (817) 410-2858 EXT.219 r < • IMPORTANT NOTE. � D. TOTAL (LEASE) AREA: 621 SQ. FT. L'OCCITANE VENDOR. CELL: (518) 320-4043 FAX: (614) 251-8411 GENERAL NOTES GC TO NOTIFY ARCHITECT & L'OCCITANE PM IMMEDIATELY F �_if�� REFER TO ELECTRICAL FAX: (518) 393-7581 E-MAIL: evenegas@donpenn.com ° AREA: 621 SF E. TOTAL (OCCUPIABLE) AREA: 576 SQ. FT. ANY INCONSISTENCIES OR DISCREPANCIES WITH PLANS (TYP). FOR DETAILS EMAIL: slathers@integra123.com � ' SALES (NET) AREA: 442 SQ.FT. NTS SHEET TITLE. STOCK NET AREA: 134 SQ.FT. 2 x rte; TRAFFIC COUNTER AMY REILLY F. TOTAL OCCUPANCY LOAD 15 PERSONS TOTAL T. SYSTEM CLIENT MANAGER STOREFRONT SALES NET AREA 442 SF : 14 PERSONS @ 30 SF/PERSON ' ( ) ( ) SHOPPERTRAK RCT CORPORATION 1. EXISTING STOREFRONT TO REMAIN&BE REFURBISHED. COVER SHEET STOCK (NET) AREA (134 SF): 1 PERSONS @ 300 SF/PERSON NOTE: G.C.TO RUN 200 W. MONROE, 11TH FLOOR 2. GC TO REFURBISH&RECAULK MALL TILES AND NEUTRAL PIERS. G. # OF EXITS REQUIRED: (1) REQ'd / (2) PROVIDED LINES, TERMINATION CHICAGO, IL 60606 NOTE: H. TOTAL EMPLOYEES: 3 PER SHIFT PROVIDED BY OFFICE: (312) 676-8260 SIGNAGE ALL VISIBLE FIXTURES AND FITTINGS TO BE OIL-RUBBED BRONZE. I. HANDICAPPED TOILET: 0 REQUIRED/ 0 PROVIDED L'OCCITANE VENDOR. MOBILE: (917) 302-1542 1. SIGNAGE IS SHOWN FOR INFORMATION ONLY. SIGNAGE IS NOT INCLUDED ( ) ( ) REFER TO ELECTRICAL FAX: XXX XXX-XXXX IN BUILDING DEPARTMENT REVIEW. SIGNAGE PERMITS AND APPROVALS PROJECT N0. 13-1802 (XXX) SHALL BE OBTAINED SEPARATELY 8Y SIGNAGE VENDOR' FOR DETAILS EMAIL: oreilly@shoppertrak.com INTERIOR SCALE: NTS 1. NO CHANGE IN OCCUPANCY OR EXTENT OF EXISTING DEMISING WALLS. CUSTOM MILLWORK RICK WOLF NOTE: 2. INTERIOR RENOVATION OF EXISTING DEMISED RETAIL TENANT SPACE; WASHINGTON SQUARE MALL VISION WOODWORKING FOR VENDORS SEE ADJACENT VENDOR DIRECTORY DATE: 04/17/13 2.1. NEW FLOORING O G 9585 SW WASHINGTON SQ. RD. NOTE: PROVIDED BY 7890 HICKORY STREE NE 2.2• NEW FINISHED CEILING NOTE: TIGARD, OR 97223 UOCCITANE VENDOR, FRIDLEY, MN 55432 FOR LANDLORD REQUIRED SUBCONTRACTORS SEE DIRECTORY ON 2.3. INSTALLATION OF NEW FINISHES AND FIXTURES GC TO REVIEW L'OCCITANE GREENHOUSE CONCEPT BOOK ' DRAWN BY. KJ G.C.TO COORDINATE& OFFICE: (763) 571-5767 x 24 DRAWING A006 2.4. NEW ELECTRICAL PANEL-VERIFY W/MEP SEPTEMBER 2012 FOR SUPPLEMENTARY INFORMATION. INSTALL AS PER DWG'S. - 1 2.5. NEW LIGHTING MOBILE: 612 875 88 0 CONSTRUCTION DRAWINGS SUPERCEDE GREENHOUSE ( ) 2 REVIEWED BY: AD REFER TO FIXTURE PLAN .6. NEW DUCTWORK EMAIL: rwolf@visionwoodworking.com CONCEPT BOOK. FOR DETAILS SHEET NO. VICINITY MAP 8 BUILDING DEPT. DATA6 VENDOR DIRECTORY5PROJECT DIRECTORY 4 SCOPE OF WORK 3 DRAWING INDEX 1 NTS NTS NTS NTS NTS NTS _ PART 2 - SITE WORK PART 1 - GENERAL L'OCCITANE - SPECIFICATIONS 07250 - FIREPROOFING 02060 - BUILDING DEMOLITION QUALITY ASSURANCE: e,�t- TABLE OF CONTENTS - MATERIALS 1<e n n Application f fireproofing • o e oofin shall include the following: Fabrication:o . pp p g J Selective Demolition. This section is Included for general reference of Obtain materials from reputable manufacturers regularly engaged GENERAL : work to be removed by the General Contractor. in the production of products and materials for the intended use. Architecture Fireproofing of new structural steel framing members, and Workmanship: Use material of size and thickness indicated or, if not PART 1 - GENERAL Urban Planning patching and repairing of existing fireproofing system which is indicated provide as required to produce strength and durability in Consult demolition plans included with project documents for Quality Standards: Except as otherwise shown orspecified, comply Quality Assurance Store Design Mixed-Use 360 Lexington Avenue removed to accommodate the installation of new work, or finished product for use intended. Work to dimensions shown, using additional notes and site specific items. with specified provisions of the following: New York,NY10017 damaged as a result of work under this Contract. proven details of fabrication and support. Submittals Retail Development www.kennethpark.com Demolition includes removal of the existing interiors, if required, but Structural Steel: Job Conditions Fireproofing System: Provide fireproofing of same material and Form exposed work true to line and level with accurate angles and p g p g not limited to Interior partitions, cabinets, suspended ceiling tile, AISC Specifications for the Design, Fabrication and Erection of MEP Consultant manufacturer as used on the existing steel, or as approved by surfaces and straight sharp edges. Ease exposed edges to a radius storefront, electrical, mechanical, etc., as required, as shown or as Structural Steel For Buildings, latest edition, including supplements Project Handling and Storage the Landlord and the Building Department. of approximately 1/32" unless otherwise shown. Form bent metal directed. there to as issued . s /(i r• 53 fro ' Y � corner to smallest radius possible without causing grain separation j - or otherwise impairing work. All items indicated or required to be demolished or removed to be AWS Dl .l "Structural Steel Welding Code". PART z SITEWORK 07270 FIRE STOP INSULATION AND SEALING legally disposed of in coordination and compliance with all landlord 02060 Building Demolition don penn consulting engineerineer Applications for fire stop insulation and sealing include, but are Weld corners and seams continuously, omplyiwith AWS procedures and regulations. All items indicated to be relocated or Qualifications for Welding Work: 635 Westport Parkway not necessarily limited to the following: recommendations. At exposed locations- and polish exposed welds reinstalled to be cleaned, serviced and prepared for proper re-use. Qualify welding processes and welding operators in accordance Suite 300 Grapevine,Texas 76051 smooth and flush to match and blend with adjoining surfaces. Any items stored during construction are to be protected to avoid with AWS "Standard Qualification Procedures". Phone:817-410-2858 Sealing pipe, duct, conduit and similar penetrations through fire damage or theft. PART 3 - PRODUCTS Fax:817-251-8411 rated walls and partitions and floors. Provide for anchorage of type required for a secure and complete Millwork/Casework: 03732 Concrete Repair SEAL: installation, coordinated with the supportingstructure. Fabricate All items indicated as existing to remain shall be cleaned, serviced Architectural Woodwork Institute (AWI) Quality Standards". � I HEREBY CERTIFY THAT THIS DRAWING in and space anchoring devices to provide adequate support for and prepared for proper continued re-use. Protect all items - 05100 Structural Steel Sealing partitions at tops where partitions join structure or p p p p WAS PREPARED BY ME S OR UNDER MY other rated construction. intended use. sufficiently during construction to avoid damage or theft. Wood Doors: NWMA Industry Standard I.S.I. - Wood Flush Doors. 05500 Miscellaneous Metals DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED/LICENSED ARCHITECT Sealing expansion and control joints in rated partitions. Shop Primer: Remove scale, rust, and other deleterious materials Cooperate and coordinate with landlord, the tenants of the Fire Rated Hollow Metal Frames: Provide fire-rated hollow metal 06100 Carpentry, General UNDER THE LAWS OF THE STATE OF from metal surface before applying shop primer. Immediately after adjacent spaces and the tenant, in scheduling work in order to frames investigated and tested as a fire rated assembly. IdentifyOREGON 06400 Millwork / Casework Fire stopping contractor should provide fire stopping certification surface preparation, brush or spray on primer at a rate to provide a cause the least inconvenience to personnel and property. See fire-rated frames with recognized testing laboratory labels, ARCHITECTURAL REG. #: 3721 as required by applicable codes. uniform dry film thickness of 2.0 mils. Provide UL label on each piece mechanical and electrical plans for specific demolition items under indicating applicable fire-rating of frame. 07200 Insulation and Waterproofing REGISTRATION,ECPIRES : 6/30/2013 of fire-retardant treated lumber. those trades. x ,07250 Fireproofing One-Part Fire-Stopping Sealant: To be used for sealing openings Fire Resistant Drywall Assemblies: Comply with fire resistant ratings 3 - PRODUCTS = `;. around cables, conduit, pipes and similar penetrations through 06100 - CARPENTRY, GENERAL as indicated and as required by governing authorities and codes. 07270 Fire Stop Insulation and Sealing - walls and partitions. 03732 - CONCRETE REPAIR Provide materials, accessories and application procedures which _ p Miscellaneous Lumber: Wood and plywood for support p p - p y or 07900 Caulking and Sealant - have been listed b UL or tested in accordance ccordance with ASTM E 119 and furring,blocking,Hailers , g, ug, - � • Biotherm Firestop Sealant: Bio Fireshield, Inc. attachment of other work includingThe extent of concrete repair work includes remaining floor for the type of construction indicated. 08100 Hollow Metal Doors and Frames `v � � n� K0, similar members. S4S, 19% moisture at time of dressing. j • Dow CorningFire Stop Sealant; Dow Corning g areas after demolition providing a level floor throughout to k^ p Co ing Corp. p g g 08210 Wood Doors • 3M Fire Barrier Caulk CP-25; Electrical Products Div. 3M receive future finishes. UL Fire Hazard Classification: Acoustical ceilings to comply with a / Grade: "Standard" grade, any species, free from knots, or other g p y ASO 1 ,.;�k�..��;- . SpecSeal Sealant; STI, Inc. fire hazard classification for flame spread, including fuel °��'' • "The Fire Satin Mineral Wool Satin Insulation: Insulation" defects that might impair the strength of finished appearance. Comply with manufacturer's requirements for installation of items contribution and smoke development classifications specified, ( Continued on ) AS02 F Sating gby pY q p p USG, or approved equal. Structural Lumber: For members 2 to 4 thick and more than 4" and finishes by other trades, including those items and finishes provide tile which has been tested, rated and labeled by UL. 08310 Access Panels MAY Q 2 2013 provided and/or installed by tenant. 07900 - CAULKING AND SEALANT in width, provide the following grade and species: Ceramic Tile Work: TCA "Handbook for Ceramic Tile Installation". 08710 Finish Hardware Applications of caulking Floor leveler concrete to be installed at low areas, holes and 08800 Glass and Glazing pp caw g and sealant include, but are not Grade: No.2 Grade or better, S4S and kiln dried. SUBMITTALS: necessarilylimited to the following: depressions. Patch cracks and broken concrete with floor patch g� Species: Douglas Fir or Yellow Pine. troweled smooth in accordance with manufacturer's instructions Manufacturers Data: Before starting any work, submit list of 09250 Gypsum Drywall Systems Strength: Fiber stress rating of not less than 1350 psi. and landlord specifications. Underlayment compound to be free materials and accessories to be incorporated in the work. List All caulking and sealant work not specifically mentioned in other 09300 Tile and Marble sections, but required to provide a neat appearing construction. Plywood Panels: Provide fire-retardant treated plywood with flowing, self-leveling, pumpable, and cement based for shall include descriptive data, catalog cuts, and other such applications from one inch thick to feathered edges. information to identify the materials as to the location or 09660 Resilient Flooring grade designation, APA A-D INT with exteriorlue, in thickness g locations of their use in the work, and the methods of Single-Component Polyurethane Sealant (General Interior indicated, or if not indicated, not less than 3/4". 05100 - STRUCTURAL STEEL 09675 Resilient Base Sealant and Caulking): Provide one of the following: installation. No consideration will be given to partial lists Rough Hardware Nails, screws, bolts, etc.. : Provide t Steel Shapes, Plates, and Bars: Comply with ASTM A 36, except submitted from time to time. 09900 Painting and Finishing 05-02-13 ISSUE FOR LANDLORD & PERMIT g ( ) type, size, • Dynatrol; Pecora Corp. material and finish as required for the applications indicated. where other type of steel is indicated. Samples: When requested, submit samples of materials to Architect for review. 10520 Fire Extinguishers and cabinets 04-19-13 PRELIM PACKAGE ISSUE • Dymonic; Tremco, Inc.. Screws for the attachment of plywood panels shall be Steel Tubing: ASTM A 500, Grade B. i none T..,i..+ n • 921; Mameco International, Inc. self-drilling, self-taping screws with countersunk type heads. Hardware Schedule: Submit final hardware schedule organized DATE REVISIONS "sets" to indicate Miscellaneous Materials: Provide primer/sealers, bond breaker Pressure Treatment: Steel Pipe: ASTM A53, Type E or S, Grade B. by specifically the product to be furnished for 11001 Equipment KEY PLAN: each item required on each door. Horizontal hardware tape and backer rod as recommended by the respective schedule are not acceptable. caulking and sealant manufacturer's for use with their product All wood and plywood permanent) installed within the interior type Y Anchor Bolts: ASTM A 307, non-headed t e unless otherwise PART 4 EXECUTION Indicated. 3 F 3 Irl r ED and substrates to which they are applied. of the building shall be fire retardant treated with Hoover Installation General Templates: Furnish templates to each fabricator of doors and "Pyro-Guard", or approved equal system containing no � ti •y, .1 Y fc / S frames, as required for re preparation to receive hardware. yF `. z K 08100 - HOLLOW METAL DOORS AND FRAMES ammonium phosphates. Threaded Fasteners: ASTM A 307, Grade A, regular low carbon steel p p DemolitionY ��Yf ,, HIM bolts and nuts. Provide hexagonal heads and nuts on all s ay� . Doors: Flush design doors, 1-3/4" thick, seamless hollow metal connections. Shop Drawings: Submit shop drawings for the following items Concrete Repair yf :.n / g _ _ _€ Provide UL label on each iece of fire re . . p tardant treated lumber. � � � � showing dimensioned plans, elevations, large scale details of construction, with smooth surfaces without visible joints or seams Millwork Casework ' . xl s,y r s=f r / .. on exposed surfaces or stile edges, except around lazed inserts. 06400 - MILLWORK/CASEWORK WeldingElectrodes: Provide electrodes, weldingrods and filler constructions, and methods of installation. Show details and �t # 1- g 1- g yy�3 f :s ; az 1. ..::.,uS 4✓has e'r'g 1f�i\11�:1 R.J� t� 'za sf�y metals equal in strength and compatible in appearance with parent locations of anchorage and fittings. Hollow Metal Frames ayss 3 ✓ 3 'moi 3S '�'/ �'I'"y&�s`k All woodwork and wood products shall comply with the Face Sheets: 18 gauge, cold rolled steel. metal joined. Finish Hardware L'OCCITANE requirements of the Architectural Woodwork Institute (A.W.I.) Mechanical & sprinkler installation, millwork, and signage. Internal Reinforcing: Channel shaped sections or continuous truss "Quality Standards," latest edition. Grade shall be "Premium". Primer: Fabricator's standard, fast-curing, lead-free, universal primer. Glass and Glazing SPACE #H6 Where the drawings or specifications conflict with these JOB CONDITIONS: AS02 form liner core reinforcement welded to both face sheets. LOCATION: standards, the more stringent shall apply. Fabrication: Fabricate and Assemble structural assemblies in shop to All work must be erformed in cooperation with the Landlords ( Continued on ) AS03 p Reinforce tops, sides and bottoms of doors with 1/8 11 channels. greatest extent possible. Fabricate items of structural steel in requirements for schedule and access to areas of work. Drywall Work All work shall have a one year guarantee. Guarantees shall be op fiff Sound Deadener: Non-combustible on all surfaces. accordance with AISC Specifications as indicated on shop against warping, delamination, opening of joints and other drawings. Properly mark and match-mark materials for field Contractor must examine the s Tile and Marble L10 (,U I A defects in materials, construction and workmanship and shall be g p Y paces in which, and the EN PROVENCE Frames: Full-welded unit construction, with corners mitered, p assembly. substrates to which the work required by this Contract is to be Resilient Flooring and Base in effect from date of substantial completion. G.C. shall repair or BOUTIQUE #057 reinforced, and continuously welded full depth and width of � installed. Notify the Owner's Representative in writing of any frame. All welds shall be ground smooth and flush. Knock down replace all defective work during this period. Connections: Weld or bolt shop connections as indicated. Bolt field conditions detrimental to the proper and timely completion of Painting and Finishing WASHINGTON SQUARE MAIL type frames are not acceptable. All cut-outs shall be protected connections, except where welded connections or other the work. Starting installation of work required by this Contract Equipment SPACE #H6 with metal dust covers, welded to frame, at back of finish Provide blocking, framing, shimming, etc. as shown and required connections or indicted. indicates acceptance of the spaces and substrate conditions 9585 SW WASHINGTON SQ. RD. hardware cutouts. for all work of this section. All blocking, framing and shimming and full responsibility for completed work. TIGARD, OR 97223 shall be of fire-retardent treated lumber or plywood. Holes for Other Work: Provide holes required for securing other work SHOP DRAWING SUBMITTAL REQUIREMENTS Gauge: 1 steel f w through PROJECT HANDLING AND STORAGE: AREA: 621 SF g 6 to structural s ee members, and or passage of other work ough SEE SHOP DRAWING SUBMITTAL REQUIREMENTS ON SHEET 07200 - INSULATION AND WATERPROOFING steel members. Cut, drill, or punch holes perpendicular to metal AS03. SHEET TITLE: Floor Anchors: Securely welded inside each jamb. Anchors shall For insulation required at ductwork, plumbing lines, etc. see surfaces. Do not flame cut holes or enlarge holes by burning. Deliver all finished materials in manufacturer's unopened containers, be properly punched for anchoring to floor. Mechanical/Electrical specifications and drawings. bundles or packages, fully identified with manufacturer's name, ARCHITECTURAL Shop Primer: Remove scale, rust, and other deleterious materials brand, type and grade. Protect from soiling and damage using Jamb Anchors: Provide minimum of 4 double stud anchors per Batt insulation: Furnish and install 3 1/2 It min.. batt insulation at from metal surface before applying shop primer. Immediately after handling equipment and storage techniques recommended by the SPECIFICATIONS jamb for use with steel stud walls and partitions. Anchors shall be exterior walls or as sound attenuation blanket where shown and surface preparation, brush or spray on primer at a rate to provide a manufacturer. standard type used by frame manufacturer for the particular as specified on drawings. Extend from floor tight to roof deck uniform dry film thickness of 2.0 mils. above unless noted otherwise. _ PROJECT N0. 13-1802 type of wall and partition construction. Where fire rated e ise. Furnish and install .004 mil. All pre finished items shall be shipped, delivered and stored In assemblies are indicated, provide anchors required to meet UL visqueen vapor barrier at exterior walls on warm side of studs. 05500 - MISCELLANEOUS METALS protective wrapping. Cut openings in wrappings as necessary to SCALE: NONE ratin avoid condensation. g Definition: Miscellaneous metals include items made from iron and G.C. shall sleeve, firestop, flash and caulk all penetrations of DATE: 04/17/13 steel shapes, plates and bars, which are not art of structural steel p p p Mortise, reinforce, drill, and to as required to accommodate all floors so that the odors or liquids will not penetrate the slab at Protect lumber and finish carpentry and millwork against dampness p q � q or other metals stems specified elsewhere. p y g p mortised template hardware. these openings. Such sleeves shall be installed according to the Y p and injury during and after delivery, and store under cover in well DRAWN BY: KJ landlord standard details. Metals: Provide steel plates, shapes and bars complying with ASTM ventilated portions of the building not exposed to humid conditions REVIEWED BY: AD Hardware Reinforcement: Not less than 1/8" thick at hinges and A 36. and maintain temperature of at least 70 degrees F. strike plate clips. Tenant is required to waterproof all wet areas of their space. SHEET NO. Tenant must use laticrete 9235 waterproof membrane or Fasteners: Provide type, sizes, materials and finish as required for the Store hollow metal work under cover on the building site on wood approved equal. Membrane to be installed per manufacturers application indicated. sills or on floors in a manner that will prevent rust and damage. Care recommendations and ANSI A108. Membrane must be shall be taken to avoid creating a humidity chamber by using a extended up the wall a minimum of 6" above-the floor slab. Primer: Fabricator's standard, fast-curing, lead-free, universal primer, plastic or canvas shelter and not venting the area covered. 09900- PAINTING AND FINISHING 09250- GYPSUM DRYWALL SYSTEMS Remove high floor levels and loose concrete. PART 4 - EXECUTION Spreader Bars: Provide removable spreader bars across bottom th Colors: As scheduled where not scheduled provide colors as Gypsum Board. Provide gypsum board of types indicated in INSTALLATION GENERAL: � � maximum lengths available to minimize end-to-end joints. Comply of frames, tack welded to jambs. � Rough in concrete in areas where patching is required such as selected by the Architect. Colors shall not be limited to g J p Y ' paste with ASTM C 36. Thickness: 5/8", except where indicated as 1/4". cracked, spalled, or holes due to removal of existing work. Comply with each manufacturers specifications and manufacturers standard colors. All paints, varnishes, stains, p Stops and Moldings: Form fixed stops integral with frames. recommendations for the installation of the various work under fillers, thinners, colors and similar materials shall be delivered in Edges shall be tapered. Gypsum board used in conjunction with fire rated walls and partitions shall be e "X". Provide 5/8" thick Provide removable stops around glazed panels; secure with Architecture Grind high spots. this section.. original containers with seals unbroken and labels intact. p type machine screws spaced uniformly not more than 12" O.C. Urban Planning water resistant gypsum complying with ASTM C 630 at all wet areas Store Design i.e. toilet rooms, mo sink area, PMU, kitchenette if sink provided). 360 Lexington Avenue At locations of construction joints in existing slab, continue joints Set all work plumb, level, true to line, and in correct relationship Paints, Enamels and Stains: Provide the best quality grade ( p p )' Finishes: Manufacturer's standard rust inhibitive primer. Mixed-Use New York,NY10017 through new floor in leveling area. Saw cut joint or place 1/1611 /16" to adjacent work. products of following manufacturer: Retail Development www.kennefhpark.com wide metal bar in the joint location coincident with existing. Studs and Runners: Screw type, roll formed, channel shaped 08210-WOOD DOORS Securelyanchor all work in lace. Benjamin Moore sections, ASTM C 645, with flange edges of studs bent back 90 p 1 MEP Consultant degrees and doubled over to form 3/16" minimum lip (return) 20 Manufacturers: Provide products of one of the following: Trenching and grooving of the floor slab are prohibited. Coring : u � ryrA3 alvanized steel with cutouts for utility runs. Include 25 3� �- ',F'� ;. x ;��r� �� "," .>�` � �10 81 and repair of slab penetrations must conform to landlords Ensure that operating parts work freely and fit neatly. Adjust All materials such as thinners, dryers, etc., shall be of same brand gauge J Y � to and bottom runners and all accessories required for a Algoma Hardwoods, Inc.. Tenant Design Criteria manual. If conduit is required for electrical hardware and catches as required. as that of painting materials or of brand recommended by the gauge p q Eggers Industries, Ar i equipment, it shall be run overhead where manufacturer of the brand of painting materials used. complete installation as recommended by the manufacturer. All gg dus es, ch tectural Door Division Fey � x r , z d ere possible. Conduit may be run below the floor slab using core holes for access Repair or replace damaged materials as acceptable to the accessories shall have a galvanized coating. Top runner track for • Weyerhaeuser Company partitions extending to structure above shall be dee le type. • VT Industries don penn consulting engineer subject to the aforementioned mall requirements. Architect. All materials shall be used as delivered, from the cans, without p g p g Yp 635 Westport Parkway thinning or adulteration, whenever possible to do so. 0Fenestra Suite 300 Furring Channels: 7/8" deep, 25 gauge roll formed galvanized hat Grapevine,Texas 76051 Clean areas removing all waste material, broom clean. Coordinate and cooperate with other trades for proper location Phone:817-410-2858 of roughing-in services and service connections required for All primers and undercoats of paint shall be tinted slightly lighter shaped sections. Flush Wood Doors: All interior flush wood doors shall be Premium Fax:817-251-8411 MILLWORK/CASEWORK: equipment and fixtures. than shade of finish coat. Grade" as defined in the AWI Quality Standards, Section 1300. Furring Channel Clips: Heavy gauge galvanized wire clips by the All interior flush doors shall have rotary cut birch veneers suitable SEAL: General: Comply with the most stringent Premium Subfloors: Prior to start of laying the finish flooring, broom clean Interior Painting: manufacturer of the furring channels used. for painted finish, 1-3/4 thick, AWI type PC-5 or PC-7 I HEREBY CERTIFY THAT THIS DRAWING requirements of AWI 1700 - Installation of Architectural _ _ WAS PREPARED BY ME OR UNDER MY q and vacuum all surfaces to be covered and inspect the (particleboard core, 5 ply or 7 ply) construction. DIRECT SUPERVISION AND THAT I AM A Woodwork Interior" as a minimum level of quality for the subfloor. Ferrous Metal Surfaces (Including existing exposed structure): Metal Trim and Reinforcement: DULY REGISTERED/LICENSED ARCHITECT installation of millwork and casework. One (1) coat Benjamin Moore "Interior Trim Primer and two (2) Fire Rated Doors: Provide faces and grade to match non-rated UNDER THE LAWS OF THE STATE OF Use latex type leveling compound for filling cracks, depressions coats Benjamin Moore "Pro-Hide Plus Alkyd Satin". Corner Beads: U.S. Gypsum "Dur-A-Bead", or an approved equal. flush wood doors. Materials and construction of labeled doors OREGON Condition finish carpentry and millwork to average prevailing shall meet the requirements of UL for class of opening. Provide ARCHITECTURAL REG #: 3721 humidityconditions in installation r and surface irregularities in subfloors to receive resilient flooring, • o areas prior to installing. sheet flooring, and carpeting. Existing Painted Metal Surfaces: Two (2) coats Benjamin Moore Casing Beads: U.S. gypsum #200A , or approved equal. additional hardware blocking in doors containing mineral type REGISTRATION EXPIRES : 6/30/2013 g Pro-Hide Plus Alkyd Satin". Spot prime damaged areas of cores for the attachment of surface mounted hardware without Install the work plumb, level, true and straight with no distortions. Remove coatings and adhesives form subfloors that would existing ferrous metal surfaces with Benjamin Moore "Interior Trim Reveal Trim: Extruded aluminum trim of sizes and shapes indicated. the use of through-bolts. Affix UL labels to doors. g g 1 prevent adhesive bond, or telegraph through the new finished Primer . Scribe and cut work to fit adjoining work, and refinish cut Water: Potable. Edge Construction: Provide manufacturer's standard laminated } floor systems. surfaces or repair damage to finish at cuts. p g Interior of ducts connecting to exhaust or return grilles, registers, edge construction for improved screw-holding power capability P R-T! Repair damaged areas in new and existing drywall surfaces or diffusers shall be given two (2) coats of flat black enamel to a Insulation: Semi-rigid mineral fiber without membrane, unless and split resistance. Cleaning and Protection: Repair damaged and defective items prior to application of finishes. Apply texture on repaired areas distance of 2 feet from outlet. otherwise indicated; USG Thermafiber Sound Attenuation Blankets", rr p pp pp Y p 08310-ACCESS PANELS y f. j�f .�k 1 to eliminate defects functionally and visually; where not possible friction fit (self-supporting). to repair properly, replace items. Adjust joinery for uniform as required to match existing adjacent surfaces. tr Wood (Painted): One 1 Benjamin Moore Interior Trim Primer - ( ) O J , . Fi r I appearance. and two 2 coats Benjamin Moore Pro-Hide Plus Alkyd Satin". Joint Treatment: U.S. Gypsum "Perf-a-Tape"joint system, or be g ass reinforced gypsum ceiling access panel as O 1 y DEMOLITION: approved manufactured by "Wind-lock" with tapered edge for tape joints CTS `=" equal.qual. Clean finish millwork on exposed surfaces. Drywall surfaces not receiving other applied finishes shall be seamless into drywall ceiling, see finish schedule. 2��3 HOLLOW METAL FRAMES: Arrange with the landlord a convenient time to perform painted. Provide the following system at locations scheduled: Joint Compound: Ready-mixed vinyl type for interior work or demolition work and install temporary protected means of p g Y approved equal. 08710- FINISH HARDWARE p y p pp q Placing Frames: Set frame accurately in position, plumbed, egress from required exits. Include temporary lighting and safety Eggshell Finish: One (1) coat Benjamin Moore "Pro-Hide Plus PVA aligned, and braced securely until permanent anchors are set. devices, all in accordance with governing state and local Acoustical Sealant for use with sound rated walls partitions): General: Furnish and install finish hardware for interior and After wall construction is complete, remove temporary braces g g Primer/Sealer ; and two (2) coats Benjamin Moore Pro-tilde Plus - ( - p ) exterior doors. p p y codes and landlord requirements. Latex Eggshell". Provide non-drying, non shrinking sealant recommended by the and spreaders leaving surfaces smooth and undamaged. drywall manufacturer. Provide sealant which is aintable wherever Y p FINISH HARDWARE: The contractor shall remove, repair, restore, and replace where Flat Finish: One (1) coat Benjamin Moore "Pro-Hide Plus PVA exposed to view. Follow DHI (Door and Hardware Institute) standards and any such work is necessary or as indicated on the drawings. Cut Primer Sealer" two (2) coats Benjamin Moore "Pro-Hide Plus guidelines and AWI (American Woodworking Institute) standards Install each hardware item in strict compliance with the all necessary openings, and patch/repair/seal same to degree Latex Flat . ( ) 1 09300-TILE AND MARBLE for hardware installed on wood doors. manufacturer's instructions and recommendations. Wherever necessary to satisfy all requirements. Insofar as possible, all Marble/ceramic/quarry tile, refer to finish and responsibility cutting and fitting is required to install hardware onto or into protrusions, marks, cracks or other evidence of a deficient or ExistingPainted Walls And Ceilings: Spot rime repaired areas, Fire rated hardware shall follow guidelines as established by: 05-02-13 ISSUE FOR LANDLORD & PERMIT g p p p schedule for sizes, colors, and manufacturers. surfaces which are later to be painted or finished in any other damaged condition shall be eliminated, unless specifically and apply finish systems of the types and number of coats Install grout as recommended by the tile manufacturer. NFPA 80 - Fire doors and windows - - way, install each item completely and then remove and store in noted otherwise. Any parts which are split, cracked, chipped, 04 19 13 PRELIM PACKAGE ISSUE specified for Drywall Surfaces. Refer to finish schedule for specifications. NFPA 101 - Life Safety Code a secure place during the finish application. After completion of spalled, broken, missing, or out of line or adjustment, 0 DATE REVISIONS ' the finishes, re-install each item. Do not install surface mounted mechanically or structurally unsafe or unsound, bent, torn or NFPA 252 - Fire tests of door assemblies 10520- FIRE EXTINGUISHERS 09660- RESILIENT FLOORING UL 1 OB - Safety fire tests of door assemblies items until finishes have been completed on the substrate. otherwise deficient or injured in any manner, shall be removed, KEY PLAN: UL 305 - Safety Panic Hardware relaced restored or repaired. Landlords representative, Fire Extinguishers: Multi-purpose dry chemical type, UL rated Resilient Tile: Refer to Finish Legend" for type, pattern, color and r^(y s # s Set units level, plumb and true to line and location. All mortises architect and tenant's construction manager must notified 1 I nominal in n I steelcontainer, manufacturer. irk g» j ,.s tix `s �s Lj s rfk ' p age us be o ed 4-A:40BC, 0 b.. capacity, enameled ed s ee h Mr rfi f�F<p Furnish owner with maintenance data, maintenance M � , R f , '& ss shall be smooth and tight. immediately of any structural or safety defects before for Class A, B, and C fires. x = t 4 rz proceeding with repairs or removals. Only the tenant's Adhesive: As recommended by the manufacturer for use with his procedures, manufacturer warranties and special tools. IN Q,i .,, 12�f�R0 Adjust and check each operating item of hardware and each construction manager need to be contacted if the defect(s) Wall Mounting Brackets: Fire extinguishers manufacturer's product and substrate to which it is applied. y Finishes: As noted on plans and schedules. f q 4 ✓ : �4 . fi fi it %S'r door, prior to acceptance or occupancy of area, to insure are limited to cosmetic finishes. standard � ba ta Mr F zj yw Y , sh M F proper operation or function of every unit. Lubricate moving (Fire extinguishers should be mounted as inconspicuously as Edge Strips. 1/8" thick vinyl with tapered or bullnose edge. A F, r xt r Keying: Genera! Contractor to coordinate cylinder and core with type lubrication recommended b the hardware Exercise extreme care during demolition so as not to damage or possible). Provide where the edges are exposed in the finished work. f fi psi y rf_yspecs. with Locksmith. General contractor to install constructionmanufacturers (gra(graphite-type) if not other recommended. disrupt an utilityorsprinkler lines which might ass through this space to service other malls aces or tenants. G.C. will bear Leveling And Patching Compounds: Latex type as cores during construction and replace with permanent at end of GLASS AND GLAZING. r LET ROOM ACCESSORIES oprior o urn-over. sole responsibility of any such disruption or damage. recommended by flooring manufacturer. job tt j p L OCCITANE General: Comply with combined recommendations and p y Accessory Items: Item in shall be models Manufacturers: See door schedule for specific items, SPACE #H6 technical reports by manufacturers of glass and glazing products All abandoned electrical and telephone conduit, plumbing as listed in the Toilet Roo e edule and 09675- RESILIENT BASE as used in each glazing application, and with recommendations lines, drain lines, and all mechanical iteryis shall be capped at manufacturers & model numbers. LOCATION: manufacture o rick Washroom E ui m c. or ,. r q p Base: Vinyl base, 0.125 gauge by high as scheduled. Style shall f FI source and removed in m o at Glass Marketing Association "Glazing Manual . a manner to meet all landlord and g g a ed equal units by ASI or Bradley. be coved. is F code requirements, unless directed otherwise. 08800- GLASS AND GLAZING �A Set glass plumb, level, true to line and in correct relationship to 11001 - EQUIPMENT Colors: As scheduled. Clear Tempered Glass: ASTM C 1048 Condition A (uncoated adjacent work. G.C. responsibilities: p - ( e EN PROVENCE Contractor shall coordinate all equipment work and placement surfaces), Type I (transparent glass, flat), Class I (clear), Quality y . q3 (glazing select), kind and thickness indicated below: BOUTIQUE #057 Adhesive: As recommended bthe resilient base manufacturer. Unify appearance of each series of glass lites by setting each 1 .- G.C. is to notify tenant immediately of any severe with the work of all other trades and make adjustments as WASHINGTON SQUARE MALL piece to match others as nearly as possible. discrepancies or irregularities discovered during demolition required to accommodate locations of equipment. SPACE #H6 which might affect the current store design. General Contractor Kind: FT (fully tempered). Thicknesses: As indicated. 9585 SW WASHINGTON SQ. RD. Install setting blocks of proper size in glazing rabbets, located is to pay special attention to available height for intended All equipment shall comply with all governing building codes TIGARD, OR 97223 1/4th of glass width from each corner. ceiling elevation, mechanical ductwork and recessed lighting. and local codes. Glass Edges: Edges not concealed b stops or moldings shall be 2. G.C. is to erect construction barricades and debris/duct g g Y p g AREA: 621 SF In addition to top and bottom "J" moldings, glass shall be set in screens per landlord's specifications. Contact landlord's Equipment shall be furnished, unloaded, unpacked or uncrated ground and polished flat, with edges slightly eased. adhesive in accordance with manufacturer's instructions. representative prior to the commencement of all demolition and placed according to the construction documents. SHEET TITLE: work. Glazing Sealants: Provide glazing sealants and preformed Remove and replace glass which is broken, chipped, cracked, 3.- G.C. is responsible for patching, repairing and leveling of the glazing tapes selected for compatibility with surfaces contacted ARCHITECTURAL abraded or damaged in other ways during construction period. existing floor slab, repair of demising walls and roof deck after in the installation. completion of all demolition and prior to the commencement SPECIFICATIONS Wash and polish glass upon completion of installation. of new construction. Coordinate with landlord responsibility in Setting Blocks: Neoprene or EPDM, 70-90 durometer hardness, performing any and all roof work. with proven compatibility with glazing sealants used. PROJECT NO. 13-1802 Spacers: Neoprene or EPDM, 40-50 durometer hardness, with SCALE: NONE CONCRETE REPAIR: proven compatibility with glazing sealants used. Do not proceed with work until visiting the site and.determining DATE: 04/17/13 conditions to decide methods of repair. Coordinate with Framing 4/17/13Framing System: Fabricate from ASTM B 221 (ASTM B221 M), conditions to decide methods of repair. Coordinate with tenant's construction manager. 6063-T5 Aluminum Alloy to profile indicated U.O.N. Form frames DRAWN BY: KJ in maximum lengths and keep joints to a minimum. To the REVIEWED BY: AD Remove and dispose of existing floor finishes where indicated on greatest extent possible, complete fabrication, assembly, and demolition plan. other work before shipment to project site. Disassemble SHEET NO. components only as necessary for shipment and installation. Ar Thoroughly clean floor slab removing conditions that will affect bond including residue from removal of adhesives, underlayments, stains, oils, etc. i SHOP DRAWINGS SUBMITTAL : " Completed Work: Match approved samples for color, texture RESILIENT FLOORING AND BASE: DRYWALL WORK: _ NOW W.Ar­'m ir = n1a G.C. TO SUBMIT (4) FOUR SETS OF DRAWINGS ON 24" X 36" SHEETS. and coverage. Cloudiness spotting, holidays, laps, brush marks g p g' Y ' p ' Match file for color and pattern by using tele from cartons In the General:- The installation required for the various drywall systems I<e n n h, k runs, sags, ropiness or other surface imperfections will not be same sequence as manufactured and packaged. Cut tile neat) shall be in accordance with USG "Systems Folder SA/923-1990", NO FAXES. acceptable. Remove, refinish, or repaint work not in q p g Y Y to and around all fixtures. Broken, cracked, chipped or deformed ASTM C754 for metal support installation, and ASTM C 840 for compliance with specified requirements. Architecture PROVIDE (4) FOUR SAMPLES NO SMALLER THAN 12' X 12 . file are not acceptable. gypsum board application and finishing. Urban Planning Clean-up and Protection: Store Design Mixed-Use 350 Lexington Avenue SHOP DRAWINGS MUST BE SUBMITTED IN A TIMELY AND Tightly adhere tile to subfloor without open cracks, voids, raising and Partition Framing: Erect framing plumb and true within 1/8 in New York,NY10017 PROFESSIONAL MANNER ON ALL ITEMS SCHEDULED BELOW: puckering at joints, telegraphing of adhesive spreader marks 12'-0". Retail Development www.kennethpark.com During progress of work, remove from site discarded paint materials, rubbish, cans and rags at end of each work day. through tile, or other surface imperfections. All partitions shall be aligned accurately according to partition MEP Consultant t' w' layout. Floor and ceiling runners shall be attached 1 x 3 ARCH.ELEMENT DESIGN/SPECIFIED REVIEWED BY COMMENTS Lay tile In grid pattern with grain in all file running in the same y g e 6 O.C. Upon completion of painting work, clean window glass and � �sf prior to direction. Consult with Architect to determine direction SUBMIT SHOP DWGS other paint-spattered surfaces. p x. aa . STOREFRONT ARCHITECT ARCHITECT beginning installation. Avoid use of cut widths less than 1/2 file at Studs shall be positioned vertically in the runners, spaced no ���� &SAMPLES room perimeter. greater than 16" o.c. or as otherwise noted. Anchor all studs s - : SIGNAGE ARCHITECT OWNER/ARCHITECT/LL SUBMIT SHOP DWGS Protect work of other trades, whether to be painted or not, located adjacent to door frames, partition intersections and j p don enn co engineer ------- ----------- -- ---------------- - ---- --- against damage b paintingand finishing work. Correct any . . . . p 9 9 g g y g. Place resilient edge strips tightly butted to tile and secure with corners to runner flanges with screws or other positive 635 Westport Parkway SPRINKLER ARCHITECT/MEP ARCHITECT/MEP/LL SUBMIT SHOP DWGS damage as acceptable to Owner. Suite 300 adhesive. Provide edging strips at all unprotected edges of tile. engagement through each stud flange and runner flange. Use Grapevine,Texas 76051 SUBMIT SHOP DWGS full length studs between floor and ceiling runners, splicing of Phone:817-410-2858 FIRE ALARM CONTRACTOR ARCHITECT/MEP g g p g & CUT SHEETS Provide Wet Paint signs as required to protect newly-painted _ Fax:817-251-8411 -- --- - --SU- --T---- - - Base: Install in as long lengths as practicable. rightly bond base to stud s shall not be permitted. HVAC ARCHITECT/MEP ARCHITECT/MEP SUBMIT SHOP DWGS finishes. At completion Of work Of other trades, touch-up and &CUT SHEETSbacking throughout the length of each piece with continuous -- restore all damaged or defaced painted surfaces. contact at horizontal and vertical surfaces. Isolate studs stem from transfer of structural loading to system SEAL. DOOR/DOOR ARCHITECT OWNER/ARCHITECT SUBMIT SHOP DWGS Y I HEREBY CERTIFY THAT THIS DRAWING HARDWARE &CUT SHEETS b use of dee le t0 runners. • y p g p WAS PREPARED BY ME R ---__--� --_ -_--- .-_ S O UNDER MY EQUIPMENT. Remove an excess adhesive or other surface blemishes from the MILLWORK ARCHITECT OWNER/ARCHITECT SUBMIT SHOP DWGS Y DIRECT SUPERVISION AND THAT I AM A — - --- - ---- -- - -- - Gen r ( Contractor's installation of tenant supplied equipment is and base, using neutral type cleaners as recommended by the All door openings shall be double studded to comply with DULY REGISTERED/ ICENSED ARCHITECT PLUMBING FIXT. �� �� UNDER THE LAWS OF THE STATE OF ARCHITECT ARCHITECT SUBMIT CUT SHEETS to be included in general bid. manufacturer. Protect installed work from damage until final Gypsum Construction Handbook published by USG. Double &ACCESSORIES OREGON � ___-....____ _- ____--_ ________....._ . __-- ____ __ acceptance b the Owner/Tenant. studs shall be secure) anchored to the jamb and head anchor p Y Y 1 STRUCTURAL ARCHITECT/STRUCT. ARCHITECT/STRUCT. SUBMIT SHOP DWGS Clips Of each door frame by screw attachment. ARCHITECTURAL REG. #: 3721 FRAMING G.C. shall notifythe construction manager immediate) of an PAINTING AND FINISHING: g Y Y REGISTRATION EXPIRE6/30/2013 -- ---- ---- __.-- - - --- -- --- S . FLOORING SAMPLES ARCHITECT OWNER/ARCHITECT SUBMIT SAMPLES damage to the equipment prior to installation. Storage Of Materials: SEE NOTE BELOW Install supplementary framing, blocking and bracing for support ii --- --- ------- -- -- --- -- All materials used on the job shall be stored in a single place SUBMIT SAMPLES and attachment of wall mounted cabinets, fixtures, equipment, WALL FINISH SAMPLES ARCHITECT OWNER/ARCHITECT G.C. shall be responsible for final hookup of all equipment, designated by the Owner. Such storage places shall be kept neat SEE NOTE BELOW and similar work. Coordinate the location of framing, blocking ------ - -- - -- - - -- --- - - -- - - includingall mechanical, plumbing and electrical work. g' g p g and clean, and any damage there to or to Its surroundings shall be - AS-BUILT DRAWINGS ARCHITECT OWNER/ARCHITECT SUBMIT AS-BUILT and bracing in wall and partitions for wall mounted equipment DRAWINGS repaired to original condition at no additional cost. Any oily rags, ;°�" A, :F All equipment manuals, instruction booklets and warrant and furniture furnished by Tenant. - , y waste, etc.., shall be removed from the building every night, and j ,x.>#:. r NOTE: FINISH SAMPLES information shall be neatly bound and turned over to the ever precaution taken to avoid dan danger of fire. Empty paint cans C, 0 F, N GC TO SUBMIT FINISH SAMPLES IN THE FOLLOWING FORMAT: y p g p y p Gypsum Board Application and Finishing: Comply with USG -WALL FINISH SAMPLES: construction manager prior to the turnover. shall be laced in the dum ster dr and with the lids off. ,� p p y "Systems Folder SA/923 and ASTM C840. -PAINTED STUCCO.3 x 3 BOARD y -WALL TILE:3'x 3' BOARD WITH GROUTING COFa� - FLOOR SAMPLES: END OF MATERIALS GENERAL Condition of Surfaces: Install gypsum exposed sum board with face side out. Do not install p -TILE:3'x 3BOARD WITH GROUTING Remove all loose dirt, oil, grease, rust, dust, paint and other foreign imperfect, damaged or damp boards. MAI 0 2Q13 material before beginning painting and finishing. Locate either edge or end joints on supports. Position boards so that like edges abut, tapered edges against tapered edges Remove hardware, hardware accessories, machined surfaces, and mill-cut or field cut ends against mill-cut or field cut ends. Do plates, lighting fixtures, and similar items in lace and not to be g IMPORTANT BID s� CONSTRUCTION NOTES FOR GC: p g g p not place tapered edges against cut edges or ends. Stagger painted, or provide surface protection prior to surface preparation vertical joints over different studs on opposite sides ofpartitions.GENERAL CONTRACTOR SHALL SUBMIT SEPARATE SHOP DRAWING/SUBMITTAL andaintin operations. Following completion letif painting of each SCHEDULE TO ARCHITECT/ PM AT SAME TIME CONSTRUCTION SCHEDULE IS p g peraons. owg m pon op g SUBMITTED. space or area, reinstall removed items. p Screw attach gypsum board to supporting members. Space fasteners in sum boards in accordance with referenced LIST PRODUCTS, MATERIALS AND EQUIPMENT FOR WHICH SHOP DRAWINGS AND gypsum Repair defects to new and existing surfaces to avoid finish failures or OTHER SUBMITTALS ARE REQUIRED IN THE ORDER N p g QU OR E I WHICH THEY APPEAR IN standards and manufacturer's recommendations. SPECIFICATIONS. the recurrences of previous failures. INCLUDE PRODUCT DATA AND SAMPLE SUBMITTALS IN SCHEDULE. Finishing: All joints to be taped and spackled. All fasteners and 05-02-13 ISSUE FOR LANDLORD & PERMIT Cut out scratches, cracks and abrasions in new and existing surfaces, metal trim shall be spackled. Apply joint compound in 3 coats 04-19-13 PRELIM PACKAGE ISSUE ALLOW SUFFICIENT TIME TO PERMIT PROPER CONSIDERATION AND APPROVAL OF fill with approved material, bring flush with adjoining surface and _ not including re fill of openings in base , and sand between ALL SUBMITTALS. finish to match adjacent surface texture. Patched area shall not ( gp ) 1 s be last two coats and after last coat. D DATE REVISIONS visible In the finished work. Seal before application of rime coat. TIME SUBMISSION TO ASSURE ADEQUATE LEAD TIME FOR PROCUREMENT OF pp p CONTRACT-REQUIRED ITEMS. Casing Beads: Provided on all exposed edges of drywall, and KEY PLAN: Existing Painted Surfaces: Remove all loose and scaling paint. Make where drywall meets dissimilar material. g Y DELAYS ATTRIBUTABLE TO UNTIMELY AND REJECTED SUBMITTALS WILL NOT SERVE AS Y certain that all paint remaining is adhered well to the surface. A BASIS FOR EXTENDING CONTRACT TIME FOR COMPLETION. , 15r R{*¢ Remove all grease, oil, and other surface contaminants which would Corner Beads: Provided at all exposed corners. � ri "`' `� ` ,sY affect adhesion of the new paint finish. Sand surfaces for proper p ' � £f Y, " s .5 R � uss�*...:.. s' £c 5 -N.5 Y ids £ 01 ? ys# z s ,., �u >s paint adhesion, and to remove glossy areas in the existing paint Sound Insulation: Fill all voids in partitions and walls indicated finish. Sand rough edges of bare areas to feather edge ar adjacent using batt or blankets in as long lengths as possible. All insulation sound. t ' shall be secure) held in lace b friction, or tin to prevent r x bM Y p Y Y tying p sagging and eventual gaps. Cut and pack insulation carefully rr f § layer Painting and finishing of patched or damaged surfaces occurring 3s „N, ,;t” NORD$]ROMy around all obstructions to provide complete and continuous ) outside the contract limit area, shall be contained to the nearest .' seal. yy .ff y. k ..r sZ ys; S!Fl,t$ £t`P IEFi i T,.y,s y change in plane or interruption of surface. L'OCCITANE Materials Preparation: TILE AND MARBLE: SPACE #H6 Refer to section 03732 "Concrete Repair" and to section 07200 LOCATION: Mix and prepare painting materials in accordance with "Insulation and Waterproofing" LIA"..10 manufacturer's directions. N EC Before setting any tile, the contractor shall assure himself that no Stir materials before and during application to produce a mixture Of tiles will have to be removed after installation to accommodate the EN PROVENCE uniform density. Do not stir surface film into material. work of other trades. All cutting, fitting, drilling and grinding of the BOUTIQUE #057 work, where necessary in relation to the work of other trades, shall WASHINGTON SQUARE MALL Application: Paint. be performed so that the work will be neatly and accurately done SPACE #H6 General: Apply paint in accordance with manufacturer's directions. and cut edges shall be uniform. 9585 SW WASHINGTON SQ. RD.TIGARD, OR 97223 Use applicators and techniques best suited for substrate and type of Conform to requirements under American National Standards material being applied. Institute ANSI A-137.1 for ceramic tile material and ANSI A-108 for AREA: 621 SF installation. Apply additional coats when undercoats, stains or other conditions SHEET TITLE: show through final coat of paint, until paint film is a uniform finish, Install per landlord's specifications, where applicable. color and appearance. ARCHITECTURAL Paint surfaces behind movable equipment and furniture same as Lay out the pattern symmetrically with even joint on all floor and wall SPECIFICATIONS surfaces. Align joints with mall pattern, where applicable.Cut and similar exposed surface. drill tile as required without marring tile, grind and fit around fixtures, etc... leave completed work free from cracked, broken, or - p PROJECT NO. 13 1802 Sand lightly between each succeeding enamel coat. damaged tile. SCALE: NONE Allow sufficient time between successive coatings to permit proper All transitions between new and existing or unlike finishes shall be drying. DATE: 04/17/13 flush and smooth. No reducer strips permitted in storefront or sales Recoat primed and sealed surfaces where there is evidence of area. DRAWN BY: KJ suction spots or unsealed areas in first coat, to assure a finish coat Protect heavily traveled, newly tiled areas as required. REVIEWED BY: AD with no burn-through or other surface defects due to insufficient priming or sealing. Install tiles using thinset method with 1/16"joints at walls and floors SHEET NO. U.O.N. Seal/wax all tile per manufacturer's specifications. Seal grout with (2) two coats of sealer. Cover finished floor with layer of building paper & masonite for protection. i I -----------------------, ----------------------------------------- r --------------------------------------- L32"MIN. w I 1 I f______________� X `_Z I I I I 36"e [ h MIN. U_ � 18" 24" X 24" ennek- dF 48"MIN.(Y) I I O MIN. PREFERREDoo MIN. Architecture FRONT APPROACH HINGE SIDE APPROACH LATCH SIDE APPROACH FRONT APPROACH 42"MIN. Urban Planning SWINGING DOOR SWINGING DOOR SWINGING DOOR SLIDING DOOR Store Design PULL SIDE PULL SIDE PULL SIDE 360 Lexington Avenue FIRE X NOTE: 54"MIN. NOTE: Mixed-Use DESCRIPTION SWITCHES TELEPHONE EXTINGUISHER New York,NY10017 X=36"MIN.IF Y=6 ", Y=54"MIN.IF DOOR HAS A CLOSER ------------------------ ---�-------------- X=42"MIN.IF Y=5 "MIN. Retail Development www.kennethpark.com I ! I I I I I I 22" ; 42"MIN.(Y) ® z I I I '� I f *+24 }NOTE: MIN.MOUNTING HEIGHTZ " Z1 1 I I 1 MEP Consultant FROM FINISHED X X I I I iv I IN. I N C— g b FLOOR TO HIGHEST Q Q X , 48"MIN. OPERABLE CONTROL ' I ' 1 POCKET APPROACH - b 00 00 9 �F SLIDING DOOR Z 10 •a' ------------------- U a �? u✓w � ',r §: }y, £s� s '' h'"F' `V 1 1 ' FRONT APPROACH HINGE SIDE APPROACH LATCH SIDE APPROACH 42"MIN.(Y) 24" don penn consulting engineer I U U 635 Westport Parkway SWINGING DOOR SWINGING DOOR SWINGING DOOR i MIN. p y PUSH IDE PUSH SIDE P IDE I US S PUSHSIDE 48"MIN. Suite 300 NOTE: NOTE: NOTE: �� Grapevine,Texas 76051 X=12"MIN.IF DOOR HAS Y=48"MIN.IF DOOR HAS Y=48"MIN.IF DOOR HAS A CLOSER BOTH A LATCH AND A CLOSER BOTH A LATCH AND A CLOSER LATCH APPROACH Phone:817-410-2858 SLIDING DOOR Fax:817-251-8411 SEAL: NOT USED 7 FIXTURES & ACCESSORIES 4 MANEUVERING CLEARANCES AT DOORS 1 I HEREBY CERTIFY THAT THIS DRAWING _ WAS PREPARED BY ME OR UNDER MY NTS NTS DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED/LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF ANY 36"MIN. 36"MIN. ANY ANY OREGON INTERNATIONAL SYMBOL OF ACCESSIBILITY DOOR SIGN AT TOILET ROOMS DIST. TER.WIDTH LR.WIDT DIST. DIST. NOTES:LETTERS AND NUMBERS ON SIGNS SHALL SIGNAGE 4 ARCHITECTURAL REG. #: 3721 BE RAISED,CONTRASTING IN COLOR,AND HAVE MAX. REGISTRATION EXPIRES : 6/30/2013 A WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5 AND 32"MIN. 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO g 4" LR.WIDT BETWEEN 1:5 AND 1:10,AND RAISED 1/32"MIN. ® ® MAX. POINT , AND BE ACCOMPANIED BY BRAILLE RAISED LETTERING. PASSAGE �� ` `vA, U_ WHERE PERMANENT SIGNAGE IS PROVIDED FOR & >� % ¢ � U Ab 3" ROOMS AND SPACES,SIGNAGE AS DESCRIBED Q Q ABOVE SHALL BE PROVIDED ON THE STRIKE UNISEX � N Q -" < ; 4�` ''�_ r. § ` uNisEx ADDITIONAL PROTECTION L WOMENS RESTROOM N 04 N E 3"MAX. SIDE OF THE DOOR. NOT REQUIRED BETWEEN WING WALLS c . t UNISEX O MIN.6"x 6"x 1/4"FIELD TRIANGLE 1/4"THICK 1 z v) WITH SYMBOLS. SUPERIMPOSED ON 12" WALKING PARALLEL TO A WALL \ I DIA.CIRCLE WALKING PERPENDICULAR OBJECTS MOUNTED Q LU TO A WALL ON POSTS OR PYLONS PROTRUDING OBJECTS 't 3" o HANGING ON WALL Q' I \ 1. SEE SPECIFICATIONS s WITH LEADING EDGES \ 5/8"HIGH MIN.TYPE FOR SIGNAGE ~ RAISED 1/32"HELVETICA ,��y 12"MIN. ABOVE 27" I + MANUFACTURER& I CLEAR WIDTH I i MA j \ 6 A.F. MEDIUM UPPERCASE MOUNTING � I�! \ LETTERS. NOTE:THE SYMBOL SHALL BE A WHITE FIGURE ON A BLUE BACKGROUND.THE \ P TECT THIS BLUE SHALL BE EQUAL TO COLOR NO. UNISEX fj;ESTROOM 2. PROVIDE SIGNAGE AREAROM \ AT ALL DOORS o 15090 IN FEDERAL STANDARDS 595B. MIN.2"x 6"x 1/4"FIELD 2 NOTED ABOVE CROSS i 0 X WITH TEXT AND GRA TRAFFIC BRAILLE BELOW TEXT. Li U_ ;� ^ 36"MIN. Q N N CD MENS RESTROOM CLR.WIDTI FOR USE IN CALIFORNIA ONLY CANE FREE-STANDING OVERHANGING PROTECTION AROUND HANDRAIL DETECTION OBJECTS WALL-MOUNTED OBJECTS TITLE 24 D-6.3.2 R R NOBJECTSNOT USED 3 ACCESSIBLE SIGNAGE 5 P OT UDI G 2 NTS NTS 05-02-13 ISSUE FOR LANDLORD & PERMIT 04-19-13 PRELIM PACKAGE ISSUE NOTE:X<48" .o Z 36 12 ,�. -� ce) MIN. MIN. I _ DATE REVISIONS — z KEY PLAN: N. - 0 \ imlvy �r<.i3t`C4 a p c w Z CCEn 36" 48" 36" 42" X 42" r°i 60"MIN. 60"MIN. x ar x j z ? awn as isF u j s y MIN. MIN. MIN. MIN. MIN. £ �, •f Y 3 1W.k ars T SHAPE 180 TURNS CLEAR WIDTH FOR WHEELCHAIR 90°TURNS TURN AROUND ° AN OBSTRUCTION TWO WHEELCHAIRS TURNING DIAMETER fg E UMEN WHEELCHAIR TURNING REQUIREMENTS IN AN ACCESSIBLE ROUTE ''P r N' � F s£r NOTE: X 5 25"; Zz 25" F' X ?vORDSTk{O�,1 IF X<20",Y=48"MAX. �, , d 10" 30 IF X=20"-25",Y=44"MAX. E _ _ MAX. X X 30" 24r£�'y3 vsa ...m, � QfFtf (d ..� 00 � r ­' L'OCCITANE � z ( , Q SPACE #H6 CD 30 10„ 30 '- J I LOCATION MAX. Z Z 48" 48" alfCLEAR FLOOR SPACE CLEAR FLOOR SPACE HIGH&LOW MAX.FORWARD REACH MAX.SIDE REACH L 0 JL PARALLEL APPROACH SIDE REACH LIMITS OVER AN OBSTRUCTION OVER AN OBSTRUCTION EN PROVENCE WHEELCHAIR CLEAR FLOOR SPACE AND REACH REQUIREMENTS BOUTIQUE #057 X FINISH FLOOR FINISH FLOOR WASHINGTON SQUARE MALL MAXIMUM SLOPE CARPET SPACE #H6 = X FINISH FLOOR Q 9585 SW WASHINGTON SQ. RD. 2 r r TIGARD, OR 97223 DOOR AREA: 621 SF DOOR FRAME BEYOND "SADDLE"TYPE THRESHOLD SHEET TITLE: CARPET(WHERE OCCURS)-114"COMP.MAX. ADA COMPLIANCE THRESHOLD PARAMETERS -------- — - -------------— & STANDARDS NOTE: CHANGES OF ELEVATION ALONG ACCESSIBLE ROUTE. FLARED SIDES =1:12 MAX. 48" PROJECT NO. 13-1802 STREET MIN. 1:10 X STREET 48 Y CURB(BEYOND) SCALE: NTS WALK ff STREET 1:12 MAX.SLOP 1:12 MAX.SLOPE DATE: 04/17/13 WALK X 1:10 WALK ADJOINING SLOPE SLOPE=Y:X NOT TO EXCEED 1:20 WHERE X IS LEVEL PLANE DRAWN BY: KJ 1:12 MAX.SLOPE CURB RAMP WITH FLARED SIDES(PLAN) BUILT-UP RAMP WITH FLARED SIDES(PLAN) CURB RAMP(SECTION) REVIEWED BY: AD CURB RAMPS SHEET NO. NOT USED 9 NOT USED 6 ACCESSIBLE ROUTE 3 NTS A F M S NUM. SPACE WALL BASE FLOOR CEILING REMARKS A.B. ANCHOR BOLT(S) F.A. FRESH AIR MACH MACHINE S SOUTH MATERIAL FINISH HEIGHT ARAN. ABANDON FIRE ALARM ABV.B. ABOVE CEILING MAS MASONRY SOIL F.B. FLAT BAR F.A.I. FRESH AIR INTAKE 100 SALES AREA P-1/P-4/WT-1 B-1/B-2 CT-1 GWB P-6 VARIES, SEE RCP - ennet dr ABV ABOVE MAT MATERIAL SAN SANITARY - A.C. AIR CONDITION (ING) MAX MAXIMUM S.C. SOLID CORE 101 STOCKROOM P-2 B-3 VCT-1 ACT ACT 12'-0" - ACOUS. ACOUSTICAL F.C. FIRE CODE MCF METAL CAP FLASHING SCHED SCHEDULE - ---F.C.E. FINISH CEILING ELEVATION AC.PNL. ACOUSTICAL PANEL MECH MECHANICAL SCR SCREEN __._______—___ - ______ __ - - .______ _- ___-_-__ _ ___ ___ __ Architecture AC.T. ACOUSTICAL TILE F.C.O FLOOR CLEANOUT S.D. STORM DRAIN A.C.T. ACOUSTICAL CEILING TILE F.D. FLOOR DRAIN MED MEDIUM Urban Planning SOAP DISPENSER --------- ----- --------__- -- -------- -------- - FIRE DAMPER MEMB MEMBRANE Store Design A.D. ACCESS DOOR,AREA DRAIN 360 Lexington Avenue ADD. ADDENDUM FDN FOUNDATION MET METAL SDG SIDING ------- _-- ________ __—_________-___ _ _ __�______ Mixed-Use New York,NY10017 ADDL. ADDITIONAL FE FENCE MFD MANUFACTURED SECT SECTION Retail Development www.kennethpark.com ADJ. ADJUST(ABLE),ADJACENT F.E.C. FIRE EXTINGUISHER CABINET MFG MANUFACTURING S.E.F. SMOKE EXHAUST FAN - -- - ---- - -- -- A.F.F. ABOVE FINISH FLOOR F.F. FINISH FLOOR MH MAN HOLE SERV SERVICE ALT. ALTERNATE F.H FLAT HEAD MIN MINIMUM SF SQUARE FEET MEP Consultant ALUM. ALUMINUM --- --- -------_-- -- ----- -- A.P. ACCESS PANEL S.H. SPRINKLER HEAD F.H.0 FIRE HOSE CABINET MIR MIRROR �" ��� �� APPROX. APPROXIMATE LY --------- ----- - --- -- -- --- - -- - --- - - - -------- - — �. ( ) FIB FIBER � MISC MISCELLANEOUS SH SHELF ARCH. ARCHITECT(URAL) FIN FINISH MLDG MOULDING SHT SHEET ? � ASPH. ASPHALT ---- --_----- ------ ----- - - -------- - - - - - - ------ ---- - :. � �� �. x :�� � � � �, ; _______ _ _ #.s�;h .y3r, .'farm. u.<fk 73> lam Y>Y -_._. 3'a^;>'�# ^ .. s..:b� H off. �' F' � N'� ��`,�-� '_ FIN.GR. FINISH GRADE SHTH SHEATHING � Es � � �• FIXT FIXTURE M.O. MASONRY OPENING SL SLEEVE �-t, �����_ AT C. AT CEILING MOD MODULE -` FL FLOOR S.O.A. SLAB ON GRADE don enn consulting engineer B FLUSH MTD MOUNTED S.N.D. SANITARY NAPKIN DISPENSER - p 9 9 MTG MEETING 635 Westport Parkway B.C. BOTTOM OF CURB FLASH FLASHING S.N.R. SANITARY NAPKIN RECEPTACLE -- - -- -------- ---------- - ------- -- - - ---- - - ---- - - ---- p y BRICK COURSE, FLDG FOLDING MULL MULLION SPEC(S) SPECIFICATION(S) Suite 300 BLOCK COURSE FL.GL. FLOAT GLASS SPKR SPEAKER - Grapevine,Texas 76051 Phone:817-410-2858 BD. BOARD FLUOR FLUORESCENT N SQ SQUARE ----------------- - -- --------- -------------- BEL. BELOW F.O.C. FACE OF CONCRETE N NEW S.R. SPRINKLER RISER BIT. BITUMINOUS F.O.F. FACE OF FINISH BLDG BUILDING F.O.M FACE OF MASONRY NORTH STA STATION SEAL: BLK. BLOCK F.O.S. FACE OF STUD NAT NATURAL STD STANDARD BLKG. BLOCKING F.P. FIRE PROOF(ING) NEG NEGATIVE sTL STEEL ROOM H E D U L E 1 I HEREBY CERTIFY THAT THIS DRAWING BM. BEAM F.R FIRE RETARDANT N.I.C. NOT IN CONTRACT S.S. STAINLESS STEEL WAS PREPARED BY ME OR UNDER MY BOT. BOTTOM F.R.P. FIBERGLASS REINFORCED PLASTIC NO NUMBER SERVICE SINK NTS DIRECT SUPERVISION AND THAT I AM A B.O. BOTTOM OF STOR STORAGE DULY REGISTERED/LICENSED ARCHITECT F.S. FULL SIZE NOM NOMINAL UNDER THE LAWS OF THE STATE OF BRK. BRICK STRUCT STRUCTURAL BRKT. BRACKET FT FOOT N.T.S. NOT TO SCALE SURR SURROUND OREGON BASMT. BASEMENT FEET KEY DESCRIPTION NOTES GENERAL LOCATION RESPONSIBILITY BULL. BULLETIN FTG FOOTING O SUSP SUSPEND(ED) ARCHITECTURAL REG. #: 3721 BULL.BD. BULLETIN BOARD FUR FURRING SW SWITCH WALL BASE REGISTRATION EXPIRES : 6/30/2013 FURN FURNISH(ED) O OIL S.W. SIDE WALK -- C FUT FUTURE OA OVERALL SYM SYMMETRICAL B-1 CLEAR PINE- 1/2"x 4"CLEAR PINE BASE PAINTED P-4 G.C.To PROVIDE AS SPETID SALES AREA FURNISHED & INSTALLED BY G.C. SYMB SYMBOL G.C.TO RUN BASE BEHIND FIXTURES TYP.SEE DETAIL 3/A106. 1. i CAB CABINET OUTSIDE AIR 3 „ STOREFRONT BASE, PROVIDED & INSTALLED BY GC B-2 STONE SOURCE-MARBLE SLAB MATERIAL BASE /8 X 12 L. MIN. CREMA MARFIL HONED FINISH STOREFRONT FURNISHED & INSTALLED BY G.C. CAR CARPET OBS OBSCURE _ _PROVIDE MITERED CORNERS & 1/8"BEVELED EDGES C.B. CATCH BASIN COLOR #46'CONCH' NOT IN PUBLIC VIEW B.O.H. FURNISHED & INSTALLED BY G.C. G GAS O.C. ON CENTER T B-3 ARMSTRONG-4 HIGH VINYL BASE, - C.B.C. CONCRETE BLOCK COURSE I GA G AGE O.D. OUTSIDE DIAMETER TREAD CEILING DIFFUSER 777777'_ - --- - ----- -- ------- - -- - ---- : J_ CEM CEMENT GAL GALLON(S) OUTSIDE DIMENSION TAPD TAPERED ----- - — -- Y , I _ GALV GALVANIZED IRON CEM.PL. CEMENT PLASTER OFCI OWNER FURNISHED,CONTRACTOR T.B. TOWEL BAR ' � CER CERAMIC GL GLASS INSTALLED T.C. TENANT COORDINATOR WALL FINISH Al, C.G. CORNER GUARD LZD G GLAZED OH OVERHEAD TOP OF CURB PRE-MIXED STUCCO PTD: BENJAMIN MOORE-"MUSHROOM CAP #177"LATEX PAINT-FLAT STUCCO FURNISHED 8Y L OC ITANE INSTALLED CEILING GRILLE G.M. GAS METER P-1 SALES AREA C T.D. TOWEL DI FINISH OPER A TO DISPENSER _ BY G.C.,PAINT FURNISHED&INSTALLED BY GC. C.H. CABINET HEATER GND GROUND OPERATOR , TEL TELEPHONE P-2 BENJAMIN MOORE- MUSHROOM CAP #177 LATEX PAINT-EGGSHELL FINISH DOOR FRAME TO BE PAINTED WITH SEMI-GLOSS FINISH ON STOCK ROOM SIDE B.O.H. FURNISHED & INSTALLED BY G.C. COAT HOOK GR GREASE OPENG OPENING - -,� - - _ -- — - -- - ---- _ -� � CHKD CHECKERED OPP OPPOSITE TEMP TEMPERED «;EIZ DRYLAC OSA INC-FKCTOR"PPLIED BRE�c��M MA-I`TE'-D-RYCAC�60034-BATCH. -- ------- OF O C.I. CAST GRADE TER TERRAllO P-3 CAL]31581H,CONTACT NO.: (909) 930-9100 MUST BE APPLIED AT FACTORY, NOT IN FIELD STOREFRONT AREA/LIGHT BOX FURNISHED 8, INSTALLED BY G.C. `� C.I.P. CAST-INN-PLACE GRAN GRANITE ORG OPPOSITE HAND T&G TONGUE&GROOVE P-4 BENJAMIN MOORE-"MUSHROOM CAP #177" LATEX PAINT-SEMI-GLOSS FINISH PAINT STOCK ROOM DOOR & FRAME ON SALES AREA SIDE. SALES AREA FURNISHED & INSTALLED BY G.C. MAY 2 201`' GRAV GRAVEL ORG ORGANIZED CONTROL JOINT THK THICK BENJAMIN MOORE: AURA EXTERIOR -BASE 632-4x, Y3-1x0, R2-0x8, Yl-12x0 RAL#1007 CK.BD CHALK BOARD GRD.RL. GUARD RAIL OSCI OWNER SUPPLIED,CONTRACTOR P_5 ( ): STOREFRONT FINISH PROVIDED BY G.C. STOREFRONT PANELS FURNISHED & INSTALLED BY G.C. II GWB/GYP.BD.GYPSUM WALL BOARD INSTALLED THR THRESHOLD FLAT FINISH _ C.L. CENTER LINE SPRAY APPLIED ENAMEL PAINT W�FLAT FINISH, BENJAMIN MOORE: T.MH TELEPHONE MANHOLE P-7 W1-0x5,Y2-4x30 (RAL #8017) STOREFRONT FINISH PROVIDED BY G.C. STOREFRONT AREA FURNISHED & INSTALLED BY G.C. CLG CEILING AURA EXTERIOR-BASE 4 632-4x, R2-4x0 Sl-5x0, — -- _ T.P. TOP OF PAVEMENT CLKG CAULKING H P CLO CLOSET T.P.D. TOILET PAPER DISPENSER - ___- --- - -- -- ---- - - --- ---- --------_ -_ _— ---- — - ---------- --- — --- - I' H HIGH PART.BD. PARTICLE BOARD T.P.H. TOILET PAPER HOLDER CLR CLEAR H.B. HOSE BIBT.O. -- _ ---- -- - - -- - -- - -- ----------- -- — - - ------ ------- --TOP OF � CMU CONCRETE MA P CONCR MASONRY UNIT P.B. PUSH BUTTON , ., •; H.C. HOLLOW CORE CNTR COUNTER T.O.C. TOP OF CONCRETE P.C. PLUMBING CONTRACTOR -------- _---- ------------- - -- --- - ---- --- - --- - - ---- ----- I C.O. CLEAR OPENING H.D. HUB DRAIN T.O.F. TOP OF FLOORING WT-1 4"x 4"GLAZED CERAMIC WALL TILE, ZELLIGES BLUE/GREY SET TILES USING BOSTIK"TILE MATE" (762 GRAY) NON SANDED THIN SET MORTAR OR OTHER THIN SKIN CARE WALLS TILE FURNISHED BY L'OC,INSTALLED BY GC.GC PERIM PERIMETER TO PROVIDE ADHESIVE,GROUT AND SEALER (TYP). CLEANOUT HD.BD. HEADBOARD --- - --------------------- ------- --- ----- - --- - ------- ---- ---- SET MORTAR COMPLYING W/ANSI Al 181. GROUT JOINTS SHALL BE 1/16" IN LATICRETE:SMOKE -------- PERF PERFORATE(D) T.O.W. TOP OF STEEL COL COLUMN HDWR HARDWARE T.O.W. TOP OF WALL GRAY #89. G.C.TO THOROUGHLY MIX TILE AS COLOR VARIES FROM BOX TO BOX. COMP COMPRESSIBLE H.D.F. HANDICAP DRINKING FOUNTAI PERP PERPENDICULAR COMPACTOR PG PAGE TOL TOLERANCE CEILING HDWD HARDWOOD T.PTN TOILET PARTITION CONC CONCRETE HK HOOK PL PLATE P-6 BENJAMIN MOORE-"DECORATOR'S WHITE„LATEX PAINT-FLAT FINISH ALL GYP. BOARD CEILINGS SALES AREA & B.O.H. FURNISHED & INSTALLED BY G.C. COND CONDITION HM HOLLOW METAL P.L. PROPERTY LINE IRAN TRANSOMI��TCEICIT�G, 2'X�r4� 1-HR-RATE�FiNE FI�SUf�ED #T$10-WTPRELQDEXL-FIRE ----- -- -- -------- ------- --- 05-02-13 ISSUE FOR LANDLORD & PERMIT CONDENSOR TRANSF TRANSFORMER ACT �%6”HEAVY DUTY T-BAR SYSTEM EXPOSED GRID AS PER ASCE STANDARD 13.5.6.2.2 STOCKROOM FURNISHED & INSTALLED BY G.C. HO HOUSE PLASTIC LAMINATE CONF CONFERENCE HORIZ HORIZONTAL PLAS PLASTIC TV TELEVISION FLOORING 04-19-13 PRELIM PACKAGE ISSUE CONN CONNECTION TYP TYPICAL H.P. HIGH POINT PLUMB PLUMBING „ „ SET TILES USING BOSTIK TILE MATE RAY-76 R OTHER IN ETM COMPLYING CONNECTOR CT-1 4 x 4 HEXAGONAL CERAMIC TILE (G O)0 0 ER TH S MORTAR CO ING W/ANSI Al 181. SALES AREA TILE FURNISHED BY L OCCITANE INSTALLED BY � DATE REVISIONS CONST CONSTRUCTION HR HOUR PLYWD PLYWOOD GROUT JOINTS SHALL BE 3/16"(5mm)IN LATICRETE 89 SMOKE GRAY&SEALED W/AQUA MIX#15 GOLD SEALER, GC. GC TO PROVIDE ADHESIVE GROUT AND CONT CONTINUOUS HT HEIGHT P.M. PRESSED METAL U MAT FINISH,G.C.TO TREAT ON SITE. PROVIDE 3/8"CONTINUOUS EXPANSION JOINT AGAINST DEMISING WALLS SEALER (TYP). CONTR CONTRACTOR HTR HEATER AND INTERIOR PARTITIONS. CAULK EXPANSION JOINT WITH LIGHT GRAY LATEX AS NECESSARY.COORDINATE KEY PLAN: PROJECT MANAGER UC UNDERCUT TILING STARTING POINTS WITH LOCATION OF ENTRANCE DOORS AND COCOMAT,SEE FINISH PLAN. RD COORDINATE HVAC HEATNIG VENTILATION &AIR _ r rpp U.F. UNDER FLOOR -- ---- - - - .- ------ ---_- ----------- - ------------ -- -------__ ----- „---------- ,<�� CORR CORRIDOR CONDITIONING PNL PANEL ARMSTRONG STANDARD EXCELON IMPERIAL TEXTURE COMMERCIAL FLOORING�8 THICK _ f, x, ti < js3 " 2y U.H. UNIT HEATER VCT-1 „ „ STOCKROOM FURNISHED & INSTALLED BY G.C. POL POLISHED 12 xl2 VINYL COMPOSITE TILE L R #51$79-ETR AN_RED-_-__ ___ _ -- - ----- ----- ._COL--- — --- 3C ---- - - - -------- _—__ .---- ------ - - ----- ---- -- . C.R. COLD ROLLED - ---- - -_- ---- - ---- ----- - xJ.. ,. HYD HYDRANT .., 2 ...,.. . ,i..^„ e. ....., ✓f:...,.., x fes• ,.,,.,,�.,,...,y.,..,:.. CEILING REGISTER POS POSITIVEITIVE UL UNDERWRITERS LABORATORY HWHOT WATER UNEX AV UNEXCAVATED <f .,.,f.. < . . 'tfkiK.:.,./CS COURSE(S) PG POLISHED PLATE GLASS HOT WATER HEATER ei c`> : s.. .. t. ... , .. �%may.. .. � CSK COUNTERSUNK UNFIN UNFINISHED . ,, :: g.. Y PAIR �;:::_. ,...,ANN �' � C.T. CERAMIC TILE U.N.O. UNLESS NOTED OTHERWISE _ ,, ;.. �. CT COUNT 1 PRE.CONC.PRECUT CONCRETE PRKG PARKINGgi U.O.N. UNLESS OTHERWISE NOTED x COURT UR URINAL I.D. INSIDE DIAMETER CTR CENTERPT POINT - - INSIDE DIMENSION IRESSURE TREATED .� P.T. IN INCHES v � Y � J ® PTD PAINTED INCAN INCANDESCENT D.A. DOUBLE ACTING INCL INCLUDEPIN PARTITION V VENT ;1 y (S) i w F# ..... ...... a. s,1.z k/s. 9 NORDSTROM FINISH & MATERIAL SCHEDULE 2 Z DBL DOUBLE V.B. VAPOR BARRIER INST INSTALL(ED) P.T.D. PAPER TOWEL DISPENSOR � .�..�>..,.., . .,,, v, �;,,.•...,.. ._. DEG DEGREE INSUL INSULATION PVC POLYVINYL CHLORIDE VC VITRIFIED CLAY _ L'OCCITANE DEP DEPRESSED INT INTERIOR V.C.T. VINYL COMPOSITION TILE • CONTRACTOR SHALL REFER TO ARCHITECTURAL SPECIFICATIONS FOR COMPLETE FINISH SPECS AND REQUIREMENTS.ALL FINISHES TO BE APPROVED BY ARCHITECT.LARGE PAINT SAMPLES TO BE APPROVED ON SITE BY ARCHITECT.PAINT TO BE LEVEL 5 FINISH. SPACE #H D.F. DRINKING FOUNTAIN INV INVERT VERT VERTICAL NOTE. NTS SAC 6 DIA DIAMETER OR ROUND Q VEST VESTIBULE DIFF DIFFUSER QT QUARRY TILE VIN VINYL LOCATION: SYMBOL DESCRIPTION DIM DIMENSION i V.J. V-JOINT DISP DISPENSOR JAN JANITOR DK DARKJ,C. JANITOR'S CLOSET R VNR VENEER ,00-41 DN DOWN JT JOINT R COEFFICIENT OF THERMAL- V.R. VENT RISER F_ ROOM NUMBER, SEE ROOM SCHEDULE L, Ocul .1 MA D.O. DOOR OPENING J.F. JOINT FILLER V.S. VENT STACK tos HC FTG RM DOM DOMESTIC RESISTANCE V.T. VINYL TILE ROOM NAME EN PROVENCE DP DEEP JST JOIST RISER V.I.F. VERIFY IN FIELD DAMPR F TNG RADIUS BOUTIQUE #057 DR DOOR K R.A. RETURN AIR 3 DETAIL NUMBER Ao05 DS DOWNSPOUT WASHINGTON SQUARE MALL SPACE #H6 K.E. KITCHEN EXHAUST RAD RADIUS �� ��� DWG(S) DRAWINGR.C. REINFORCED CONCRETE S) K.P. KICK PLATE W WEST SHEET NUMBER DWL DOWEL K.O. KNOCK OUT R.D. ROOF DRAIN WIDE 9585 SW WASHINGTON SQ. RD. E RDWY ROADWAY WASTE 2 -0 ELEVATION NUMBER TIGARD, OR 97223 W/ WITH SHEET NUMBER A005 EA EACH REFR REFER W/O WITHOUT E.A. EXHAUST AIR L LENGTH REF REFRIGERATE W.B. WOOD BASE 621 S F AREA: E.F. EACH FACE L.D. LINEAR DIFFUSER REG REGISTER 3 SECTION / DETAIL NUMBER W.C. WATER CLOSET A005 SHEET NUMBER SHEET TITLE: E.H.H. ELECTRIC HAND HOLD LAB LABORATORY REINF REINFORCE(D) EL ELEVATON LAM LAMINATE(D) WD WOOD ELEC ELECTRIC (AL) RELOC RELOCATE WDW WINDOW ELEV ELEVATOR LAV LAVATORY REM REMOVAL W.G. WIRE GLASS EMER EMERGENCY L. POUND REMOD REMODEL W.H. WALL HUNG 2A �- PARTITION TYPE, SEE DETAILS,SHEET A004 E.MH ELECTRIC MANHOLE L.C. LEAD COAT(ED) ENCL ENCLOSURE LG LONG RET RETAIN W.I. WROUGHT IRON SCHEDULES ENT ENTRANCE LH LEFT HAND RETURN W.M. WIRE MESH E.O.D. EDGE OF DECK L.H.R. LEFT HAND REVERSE REQ'D REQUIRED WATER METER O NEW DOOR (SEE DOOR SCHEDULE,SHEET E.O.F. EDGE OF FLANGE LKR LOCKER RESIL RESILIENT WP WATERPROOF(ING) ', - A003) E.O.R. EDGE OF ROAD LL LEASE LINE REV REVISED W.P. WORK POINT PROJECT NO. 13-1802 O i O EDGE OF ROOF LANDLORD R.H. RIGHT HAND W.S. WASTE STACK E.P. ELECTRIC PANELBOARDL.P. LIGHT POLE R.H.R. RIGHT HAND REVERSE WT WEIGHT EXISTING DEMISING PARTITIONS TO REMAIN SCALE: NTS EQ EQUAL LOW POINT RM ROOM W.W.F. WELDED WIRE FABRIC (FIELD VERIFY EXACT LOCATION) EQUIP EQUIPMENT 04/17/13 LTL LINTEL RND ROUND W.W.M. WELDED WIRE MESH E.W. EACH WAY DATE: E.W.C. ELECTRIC WATER COOLER LT LIGHT R.O. ROUGH OPENING E.W.H. ELECTRIC WATER HEATER LTG LIGHTING RR RAILROAD Y NEW PARTITION EXIST EXISTING LT.WT. LIGHT WEIGHT YD YARD (SEE PARTITION TYPES) DRAWN BY: KJ EXH EXHAUST EXP EXPANSION REVIEWED BY: AD EXPD EXPOSED E.J. EXPANSION JOINT SHEET NO. EXT EXTERIOR ABBREVIATIONS 5 NOT USED 4 SYMBOL LEGEND 3 NTS NTS QTY. DESCRIPTION MANUF. MODEL FINISH REMARKS DOOR # DOOR SIZE / LOCATION MATERIAL DOOR HARDWARE HARDWARE THRESHOLD H/J DETAIL FRAME RATING RESPONSIBILITY REMARKS TYPE FINISH GROUP FINISH DETAIL EXISTING DOOR & HARDWARE TO REMAIN.GC TO CONFIRM ALL 3'-0" 10'-0" (enne HARDWARE SET 1 -EXISTING ROLLING GRILLE O A EXSTG 3-0 X 10-0 EX. EX. 1 EX. 4B/AO03 - AL N/A GC EXISTING TO REMAIN. GC TO VERIFY ALL CONTROLS IN WORKING CONDITION & CONTROLS IN WORKING CONDITION & REFURBISH TO LIKE-NEW. STOREFRONT ROLLING GRILLE REFURBISH TO LIKE-NEW. al NEW 3-0"X 7-0"X 1 3/4" P4:SALES SIDE OIL RUBBED B SALES AREA TO STOCK ROOM HM P2:STOCK SIDE 2 BRONZE 4C/AO03 3C/Ao03 HM N/A GC HEAD DETAIL SIMILAR TO JAMB; REFER TO HARDWARE SCHEDULE FOR MORE INFO. 2 . 3O C EXISTING REAR EXIT DOOR HM P2:STOCK SIDE 2 OIL RUBBED 4D/AO03 3C/AO03 HM N/A GC EXISTING TO REMAIN. GC TO REFURBISH TO LIKE-NEW. Architecture _. E: MALL SIDE BRONZE Urban Planning --- Store Design 360 Lexington Avenue Mixed-Use New York,NY10017 Retail eve opmen www.kennefhpark.com MEP Consultant DOOR SCHEDULE Iy �»c3: :£�Q '' r.x yr /FX� syr � Yx --- -- -- ---- --- NTS ti t? $`: .�'�- .�• y?��� ;:. 3Yfi �aORFCLic ASF .. k don pann consulting engineer 635 Westport Parkway Suite 300 HARDWARE SET 2 - STOCK ROOM DOOR EXISTING DOOR&HARDWARE TO REMAIN; Grapevine,Texas 76051 GC TO VERIFY ALL CONTROLS IN Phone:817-410-2858 1 LEVER SCHLAGE AL10S-ATHENS OIL RUBBED BRONZE _ Fax:817-251-8411 613 WORKING CONDITION &REFURBISH TO --1 _1 I -- LIKE-NEW. - -- - HINGES - ---- I-- --- - 3 (41''x 42') BALL BEARING BALDWIN 1046-102 OIL RUBBED BRONZE - 1_� _L I 1__.. SEAL: -- CLOSER U EXISTING ROLL UP I HEREBY CERTIFY THAT THIS DRAWING CLP-1 601(BF)-T PROVIDE PARALLEL ARM MODEL - GRILLE TO REMAIN WAS PREPARED BY ME OR UNDER MY 1 CLOSER NORTON STOCK RM.SIDE OIL RUBBED BRONZE PREFIX" " HOLLOW METAL =-L_. -_-=1 ( P IF NECESSARY EXISTING HOLLOW / } _� EXISTING R.U.G.PANIC DIRECT SUPERVISION AND THAT I AM A OIL RUBBED BRONZE \ METAL FRAME & DOOR / FRAME � HARDWARE TO 1 KICKPLATE Iv / Z_ -_L.-__ _ DULY REGISTERED/LICENSED ARCHITECT ES 10 x 34 - \ USI OB HOLLOW METAL - J REMAIN;GC TO VERIFY \ / -__i_._- _ UNDER THE LAWS OF THE STATE OF DOOR —: ___ _ _ ALL CONTROLS IN \ / 11 -f --� --I---J WORKING CONDITION OREGON 1 DOME FLOOR STOP IVES FS 17 OIL RUBBED BRONZE - \ / REFER TO SCHEDULE > _ - __ &REFURBISH TO LIKE p \ / FOR NEW FINISH (TYP). o _ _ -- __-- _ _-1 ARCHITECTURAL REG. #': 372 _ NEW. 3 SILENCER GLYN JOHNSON #20 BROWN - --I- --- - -- EXISTING DOOR � - REGISTRATI PIRES : 6/30/2013 "—J HARDWARE TO EXISTING R.U.G. EXISTING DOOR & HARDWARE TO REMAIN. GC TO CONFIRM ALL Q \ - Z - I-- I INTERIOR KEY ACCESSNi HARDWARE SET 3 - EXISTING REAR EXIT DOOR REMAIN _ CONTROLS IN WORKING CONDITION & REFURBISH TO LIKE-NEW. / \ G.C.TO PROVIDE 10 X 34 _ 1 1 TO REMAIN;GC TO A0131 ` - / \ KICK-PLATE W/ BEVELED _z __- __1__ __ -r VERIFY ALL CONTROLS / C� \ EDGES @ 3 SIDES FOR - --_- IN WORKING : 1 N \\ STOCKROOM DOOR ON M = CONDITION & ' SALES AREA SIDE REFER TO 4 REFURBISH TOF. / ::::::::::: :: SCHEDULE FOR SPEC. LIKE-NEW. / � 3-0 R Se� Ji F' ................................. -- - - -- -- 6'-0"(V.I.F.) TOP OF FLOOR LINE 3'-011 - -- -- - ------ - TYPE D - NOT USED TYPE C TYPE B TYPE A Y OF vv MAY 1 9. ;01 tiff HARDWARE SCHEDULE 5 DOOR TYPES 2 NTS %11 _ 11-0,1 1. ALL DOORS MUST BE OPERABLE WITHOUT SPECIAL KNOWLEDGE OR EFFECT W/ LEVER TYPE HARDWARE IN COMPLIANCE WITH STATE & LOCAL CODES. 20 GA.STEEL STUDS RUNNER FASTENED @ DOOR OPENING, 2. LATCHING AND LOCKING DOORS THAT ARE HAND-ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A WITH SCREWS TO TYP. -- HM FRAME TO BE SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO STUDS (AT HEIGHT PAINTED TO MATCH PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE PERMITTING SCREW ADJACENT WALLS AS ABOVE IN EGRESS DIRECTION. ATTACHMENT OF 2 REFER SCHEDULE FACINGLO 3. ALL HARDWARE FINISHES FOR PARTITION TYPE 05-02-13 ISSUE FOR LANDLORD & PERMIT N SHES TO BE AS SCHEDULED. ADJACENT FINISHED TO MATCH. SUBMIT HARDWARE SELECTIONS TO ARCHITECT � DOUBLE FOR REVIEW WITH CLEAR NOTATION OF FINISHES BEING UNAVAILABLE. LOCATE JAMB ANCHOR REINFORCING BOXED STUDS @ JAMB 04-19-13 PRELIM PACKAGE ISSUE 4. ALL DOORS TO BE KEYED ALIKE. CLIPS ABOVE HINGE REINFORCEMENTS&JUST D DATE REVISIONS 5. HAND-ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30"AND 44"ABOVE THE FLOOR. BELOW TOP w REINFORCEMENTS � O Z Q KEY PLAN: � o � 6. ALL DOORS TO BE SINGLE ACTION U.O.N. - CLIPS ON STRIKE SIDE > TO OCCUR DIRECTLY _ LU< y A jr 7. ALL HOLLOW METAL FRAMES PAINTED TO MATCH DOOR FINISH AND ALL DOORS TO BE SHOP PAINTED PER SCHEDULE. OPPOSITE OF HINGE SIDE FLOOR ANCHOR as N ' ' ' k � CLIPS SECURED TO yY x � �%•n.. ,� `u' ,/�trliY �� d -: g �� -zi : ',s �sPs '��. �1�4$ a s d'`x.:.o z���x " �' �:�'',:�¢r�'�,,�2:Yrrw '�.,� xis tn; £irp/L 1�,✓,.� 8. G.C.TO PROVIDE CONSTRUCTION CORES FOR ALL DOORS REQUIRING SECURITY DURING CONSTRUCTION. ALL CONSTRUCTION FLOOR CORES MUST BE COMPATIBLE WITH SPECIFIED CYLINDERS. G.C.TO VERIFY PRIOR TO CONSTRUCTION. WITH NO LESS THAN .. TWO SUITABLE sX 9. UNLESS OTHERWISE SPECIFIED ALL HARDWARE IS FURNISHED BY THE G.C. FASTENERS y ` ELF DOOR AS ANCHOR PER MANUF. .1 10. AT THE TIME OF TURNOVER, THE GENERAL CONTRACTOR SHALL ENSURE THAT ALL CONSTRUCTIONS CORES HAVE BEEN REPLACED SCHEDULED RECOMMENDATIONS w 5 �1 h y 7� ¥�( ..,,,,,/:. l y;£f'CX 13a:.n:. :ORI)STRO 11. ALL DOORS SHALL BE 1 3/4 THICK, UNLESS NOTED OTHERWISE. ,� � 12. ALL DOORS SHALL BE TRIMMED AT THRESHOLD TO PROVIDE 3/4"MINIMUM CLEARANCE ABOVE FLOOR FINISH MATERIAL TO PERMIT /.,,., ...�.....,,..,.s..fi:'i..,.,nac...l u ...s<......,N FULL DOOR SWING. f L'OCCITANE 13. CONTRACTOR SHALL VERIFY ACTUAL DOOR HEIGHT REQUIRED FOR DOOR FRAME SYSTEM. DETAIL D DETAIL C DETAIL B DETAIL A SPACE #H6 TYP. DOOR FRAMING TYPICAL JAMB DETAIL NOT USED NOT USED 14. PROVIDE DOOR AND FRAME ASSEMBLY WITH APPROPRIATE LABELS FOR USE IN WALLS WITH REQUIRED FIRE RATING AS NOTED ON LOCATION: SCHEDULE. 15. DIMENSIONS FOR UNDERCUT DOORS IF ANY SHALL BE MEASURED FROM TOP OF FINISH FLOORING MATERIAL. DOOR DETAILS 3U f.1 I-X 16. DOOR IN THE FULLY OPEN POSITION SHALL NOT REDUCE THE REQUIRED EXIT WIDTH BY MORE THAN 4 INCHES. N.T.S. EN PROVENCE 17. EXIT DOORWAYS SHALL BE NO LESS THAN 36" IN WIDTH AND NO LESS THAN 6'-8"IN HEIGHT. PROJECTIONS, INCLUDING PANIC BOUTIQUE #057 HARDWARE,SHALL NOT REDUCE THE OPENING TO LESS THAN 32"CLEAR WIDTH. WASHINGTON SQUARE MALL 18. THERE SHALL BE A LEVEL AND CLEAR FLOOR OR LANDING ON EACH SIDE OF A DOOR. THE LEVEL AREA SHALL HAVE A LENGTH IN MALL CORRIDOR STOCK ROOM i SALES AREA STOCK ROOM MALL SALES AREA SPACE #H6 THE DIRECTION OF DOOR SWING OF AT LEAST 60"AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 48"AS _ ----_- - 9585 SW WASHINGTON SQ. RD. MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN THE CLOSED POSITION. THE FLOOR OR LANDING SHALL BE LESS THAN TIGARD, OR 97223 OR EQ.TO 1/2" LOWER THAN THE THRESHOLD. _ ! CERAMIC TILE (CT-1) ON MASTIC 19. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND A MINIMUM OF 18"PAST THE STRIKE EDGE AREA: 621 SF FOR INTERIOR DOORS. HM DOOR HM i 1/8"MAX. GREY VINYL COMPOSITE TILE DOOR OF ROLLING GRILLE CE - JOINT SHEET TITLE: 20. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR (VCT-1) VINYL COMPOSITE TILE (VCT 1) E EXISTING MALL TILE TO REMAIN DOORS SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING - - ARMSTRONG VT8 RUBBER MTL U CHANNEL P 3 OR FOLDING DOORS. COMPENSATING DEVICES, FIRE RATED DOORS OR AUTOMATIC DOOR OPERATORS MAYBE INCREASED TO TRANSITION STRIP, SCHLUTER-RENO RAMP 1.8 I OIL RUBBED BRONZ SCHLUTER FINISH, PROVIDED BY DOOR THE MAXIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. SHADOW GRAY ANODIZED, G.C.TO SELECT ALI1PN STRIP TO TRANSITION FROM S.F. VENDOR, APPROPRIATE SIZE j ALIGN INSTALLED BY GC. SCHEDULES MALL TO SALES FLOOR. 21. ALL METAL FRAMES ARE TO BE WELDED FRAMES. CERAMIC TILE (CT-1) MOSAIC TILE CERAMIC TILE (CT-1) PROJECT NO. 13-1802 DOOR Q 00U DOOR � SCALE: AS NOTED 1 4 LINE OF EXISTING CONCRETE SLAB LINE OF EXISTING CONCRETE SLAB LINE OF EXISTING CONCRETE SLAB /$ 1�211 LINE OF EXISTING DATE: 04/17/13 NOTE:TRANSITION SHALL BE FLUSH U-CHANNEL FRAME TO BE CONCRETE SLAB G.C.TO PREP SLAB AS REQUIRED ADHERE TO BLOCKING. DRAWN BY: KJ ENSURE NO VISIBLE FASTENERS. WATERPROOF WOOD BLOCKING TRANSITION D TRANSITION C TRANSITION B TRANSITION A FASTENED TO SLAB REVIEWED BY: AD VCT TO SLAB TILE TO VCT ENTRY THRESHOLD ENTRY MAT SHEET N0. DOOR & HARDWARE NOTES 5 SILL & FLOOR TRANSITION DETAILS 4 NTS NTS I HEIGHT STUDS BOTTOM TOP TRACK 362 CJS 20 VERTICAL STRUT AT 8'-0" 362 CJS 20 VERTICAL STRUT o X TRACK 8'-0"SPAN 1 1'-6"SPAN � 3/4" 16 GA. COLD-ROLLED °` 3-5/8"x 18 GA. NESTED * ... . , di O.C. MAX. EACH WAY WITH FIRST 4'-0"EACH WAY (TYP.) AS NOTED 2 1/2 x 19 GA. 2 1/2 x 18 GA. 2 1/2 x 16 GA. N.A. STRUT TO BE WITHIN 4'-0"OF EACH + + CHANNEL SPACED AT 4'-0" BRACES EACH WAY AT N-0"O.C. HORIZONTALLY. -- ---- - - WALL FASTENED TO MAIN RUNNER O.C. MAX. SCREW UP TO 16 FT. 3-5/8"x 25 GA.** 3-5/8"x 18 GA. 3-5/8"x 18 GA. -5/8"x16 GA D AND STRUCTURE ABOVE 250 S 137-33 DIAGONAL u TOGETHER @ 7'-0"O.C. EACH 16FT.TO 20FT. 6"x 20 GA. 6"x 18 GA. 6"x 18 GA. 6"x 18 GA. BRACING (TYPICAL) OFLANGE 20FT.TO 26FT. 6"x 18 GA. 6"x 18 GA. 6"x 18 GA. 6"x 18 GA DL Architecture 1-1/2 x 3 x 16 GA. Urban Planning CHANNEL CLIP ANGLE 1/4" 45 + + + LESS THAN STUD WIDTH.-TYP. NESTED STUD BRACING Store Design New York,Lexington Avenue 17 ue Mixed-Use 360 Lexin t t4- 4 ATTACH WITH (4) 5/8" #S-12 Retail Development www.kennethpark.com 362 CR S @ U O.C. . �/7, SCREWS OR 3/4"WELDS IN (3) * NON-BEARING STUD WALLS ONLY. CROSS RUNNERS PLACES ** SEE PARTITION DETAIL TYPES FOR EXACT MTL. GA NUMBERS (LAID FLAT) NOTE: 4'-0"O.C. 1.ALL STUD WALLS AND PARTITIONS REQUIRE GYP. BD.BOTH SIDES FOR THE MEP Consultant ONLY APPLY TO HT. >4' 3/4"MIN. CLR. CROSS OR MAIN RUNNER FULL HEIGHT OF THE STUDS UNLESS SPECIFICALLY DETAILED OTHERWISE). 362 CJS 20 @ 16"O.C. BETWEEN STRUCTURAL 2'-o i/z' STUDS ( DECK AND CEILING MAx• 2.ALL SUSPENDED WALLS SHALL HAVE GYP.BD.WHICH EXTENDS 4"ABOVE CEILNG MAIN RUNNERS METAL STUD FRAMING.-TYP. 362CJS20 VERTICAL STRUT THE SUSPENDED CEILING (UNLESS SHOWN AND/OR NOTED OTHERWISE BY THE r ARCHITECT). o N CLG ELEV. 3.ALL STUD WALLS AND PARTITIONS SHALL HAVE CONTINUOUS LINES OF TYP. SEISMIC FRAMING D ETA I L 45° don penn consulting engineer BPLUS 4" BRIDGING SPACED AT 4'-0"MAX.ON CENTER.THE BRIDGING SHALL BE 635 Westport Parkway SCALE: N.T.S. SECURELY FASTENED TO THE STUDS WITH EITHER SCREWS OR WELDS. Suite 300 E/50 GYPSUM BOARD CEILING ON �\ // Grapevine,Texas 76051 z Z SUSPENDED FRAMING SYSTEM 4.ALL STUDS SHALL BE"CEE"STUDS WITH FLANGE STIFFENERS. LL w \\ // Phone:817-410-2858 \\ // 5.THE MATERIALS AND DETAILS SHOWN ARE FOR TYPICAL INSTALLATIONS. Fax:817-251-8411 \\ // WHERE THE STUD MANUFACTURERS RECOMMENDATIONS OR LOCAL PER PLANS \ // ORDINANCES ARE MORE RESTRICTIVE,THEY SHALL APPLY. SEAL: NESTED BRACING @ 6.TYPICAL FASTENER: I HEREBY CERTIFY THAT THIS DRAWING EMT TIGHT TO STRUCTURE ABOVE 4'-0"O.C. MAX. BRACE WAS PREPARED BY ME OR UNDER MY Ole LENGTH MAY NOT A.STEEL STUDS TO STEEL STUDS OR TRACKS: T 12 GA. VERTICAL HANGER WIRE 1/2"EMT TIGHT TO STRUCTURE EXCEED 16'-0" #8-18 x 1/2"TEKS/2 WITH PHIL. PAN HEAD FOR 25GA.OR 20GA. #10-16 x 9/16" DIRE SUPERVISION C SU SION A ND THAT I AM A DULY EDAICENSED ARCHITECT ABOVE TEKS/3 WITH PHIL. PAN HEAD FOR INTERCONNECTION OF 18GA.OR 16 GA. UNDER THE LAWS OF THE STATE OF STRUT REQUIRED @EACH SEISMIC RESTRAINT, 12' 12 GA. VERTICAL HANGER WIRE B.STEEL STUDS OR TRACKS TO WOOD PURLINS,GIRDERS AND BEAMS: OREGON O.C. EACH WAY.3/4" EMT NOTCH #14-10 x 1/2"H.W.H.TYPE"S"METAL-TO-WOOD TEKS. ARCHITECTURAL REG. #: 372 4-12 GA.SPLAY WIRES EACH SEISMIC RESTRAINT, 12-0 3-5/8 x 18 GA.TOP TRACK. OVER MAIN RUNNER COMPRESSION STRUT REQ'D @ 16 GA.TRACK OVER— C.STEEL STUDS OR TRACKS TO STRUCTURAL STEEL(TUBE STEEL,WIDE REGISTRATION EXPIRES : 6/30/2013 O.C. EACH WAY SCREW TOGETHER AT FLANGE BEAMS, COLUMNS,GIRDERS,ETC.): 4"MIN LAP 12"O.C.,STAGGERED TEKS/3 OR TEKS/4-GAUGE AND LENGTH AS REQUIRED FOR THE COMBINED WALL ANGLE 3/4" EMT NOTCH OVER MAIN THI KNES F THE MATERI L T D C S O A O BE RILLED. � ?, RUNNER � D. PLYWOOD TO STEEL STUDS: DRILL 5/32"HOLE FOR 1/8" BOLT&LOCK NUT 25 GA 5 —', DRILL 5/32" HOLE FOR 1/8"BOLT& #10-24 x 3/4"TEKS/3 (PLYMETAL TEKS) WITH THIN WAFER HEAD. !' p AFTER CEILING IS LEVELED. LOCK NUT AFTER CEILING IS t MAIN BEAM LEVELED. E.GYP. BD.TO STEEL STUDS: . CEE STUDS AT #7 x 1/4"HI-LO TYPES BUGLE HEAD SCREWS FOR 3/8 TO 5/8"GYP,BD.TO 1! 1I! 16 O.C. MAX.SEES, _. 25GA. OR 20GA.STUDS. 4-12 GA.SPLAY WIRES. OTHER DETAILS FOR ADDT. INFO. #6 x 1/4"TYPE"S-12"BUGLE HEAD SCREWS FOR 3/8"TO 5/8"GYP. BD.TO 18GA. OR 16GA.STUDS OR TRACKS 5/8 TYPE X GWB. ATTACHED TO CEILING , FRAMING W/ #8 BUGLE HEAD SCREWS @ 12" 4 ,� O/C-MIN. 1/4"THROUGH METAL FRAMINGNOTE: q 5 — INSTALL BRACING AT IMPORTANT NOTE: 1 . 12'-0"O.C. EA.WAY 3/4 18 GA. COLD MAY 0 ROLLED CHANNEL. INTERIOR NON LOAD BEARING FRAMING AND WITHIN 4'-0"OF BRIDGING SPACED AT METAL STUDS TO BE DEITRICH METAL'PRO STUD'. ICC NUMBER-ER0171, OR EQUIVALENT. CROSS FURRING CHANNEL SCREW TO MAIN BEAM W/ PERIMETER WALLS N-0"O.C. HORIZONTALLYICC REPORT CAN BE DOWNLOADED AT: #8 BUGLE HEAD SCREWS-MIN. 1/4"THROUGH METAL http://www.dietrichmetalframing.com/library/pdf/ER_0171%20DMFCWBS.pdf FRAMING AND SECURE ENDS TO WALL ANGLES WITH NOTE: STOREFRONT&LOAD BEARING FRAMING POSITIVE ATTACHMENT.SEE ALSO SPECIFICATION SHEETINSTALL BRACING AT 12'-0" METAL STUDS TO BE DEITRICH METAL'HDS'. ICC NUMBER-ESR 1166P, OR EQUIVALENT. AS02 AND USG TYPICAL INSTALLATION O.C. EA. WAY AND WITHIN MAIN RUNNER BOTTOM TRACK WITH ICC REPORT CAN BE DOWNLOADED AT: 4'-0"OF PERIMETER WALLS HILTI #37NKS12 DRIVE http://www.dietrichmetaIframing.com/PDF/Structural%2OProducts%20-%20%201CC%20-% CROSS TEE PINS AND R36 DISCS AT 20ESR-1 166P%20with%20CBC%202007%20Supplement%20Aug%201%202010.pdf i NOTE: FOR REFERENCE ONNOTE: A MINIMUM WALL ANGLE OF E.M.T. DIA. MAX LENGTH MTL. ANGLE MAX. LENGTH AT LEAST A TWO INCH HORIZONTAL E.M.T. DIA. MAX LENGTH MTL. ANGLE MAX. LENGTH 24"O.C., MAX. TYP.SUSPENDED CEILING SEE 4/A401 1/2" 3-9 L 2 x 2 x 1/8 LESS THAN 6-6 LEG SHALL BE USED AT PERIMETER 1/2" 3'-9" L 2 x 2 x 1/8 LESS THAN 6-6" WALLS AND INTERIOR FULL HEIGHT 3/4" 5-2" L 3 x 3 x 3/16 GREATER THAN 6-6" PARTITIONS.THE FIRST CEILING TILE 3/4" 5-2" L 3 x 3 x 3/16 GREATER THAN 6'-6" 05-02-13 ISSUE FOR LANDLORD & PERMIT 1" 6'-6" SHALL MAINTAIN 3/4"CLEAR FROM 1" 6'-6" ` THE FINISH WALL SURFACE. 04-19-13 PRELIM PACKAGE ISSUE ` TYP. � DATE REVISIONS GWB CLG. DETAIL TYP. SEISMIC A.C.T. CLG. DETAIL C SCALE: N.T.S. A SCALE: N.T.S. KEY PLAN: {r�h✓'� L 'c. s Yr f ks , o ( `C �i3: £ A f / y 112" k S P 10 k3�isv s "y,4 3 , .•Gf+'�i."-';i k`5r 4 gy w`v s£Y# fsa 'e �jY➢s . SEISMIC CEILING DETAILS 3hq PARTITION FRAMING SCHEDULE & DETAILS MIN ,k z �. +I x NTS NNI s NTS $ S- ^o'h i?' .w fes., MOORE r� ':34..s. Clx :w .✓ ;..r > rr NOTE: BLOCKING FOR WALL FIXTURES t y ., GC TO PROVIDE ALL NECESSARY FIRE RETARDANT s �� NORDSTROM xs -, BLOCKING REQUIRED FOR ALL WALL MOUNTED FIXTURES. SEE FIXTURE DRAWINGS FOR MORE INFORMATION, EXACT r UNDERSIDE OF DECK UNDERSIDE OF DECK UNDERSIDE OF DECK "# w" " �.sr"k'""# `"'"' `' h"-"N`'`" DIMENSIONS AND FURTHER FIXTURE DETAILS. L'OCCITANE ❑ 18 GA.TOP TRACK WITH HILTI ❑ 18 GA.TOP TRACK WITH ❑�.....; PAINTABLE FIRESTOP SPACE #H6SEALANT "X-U" FASTENERS AND R36 HILTI"X-U"FASTENERS AND LOCATION: DISCS AT 24 O.C., MAX. R36 DISCS AT 24„O.C., (ICC#-ESR-2269) MAX. (ICC#-ESR-2269) FULL HEIGHT INSULATION _ BY TENANT GC IF NOT ” ��------ EXISTING (TYP) E VA -A EN PROVENCE z z (1) LAYER OF 5/8"GYP. BD. ON ONE SIDE OF NEW BOUTIQUE #057 ADJACENT LOITAN METAL STUDS TO 6 ABOVE E FINISHED CEILING TENANT WASHINGTON SQUARE MALL SPACE #H6 UNDERSIDE OF CEILING AS UNDERSIDE OF CEILING ❑ 9585 SW WASHINGTON SQ. RD. ❑ SCHEDULED. SEE 3/A004 ❑ AS SCHEDULED. SEE 6 MTL DEMISING WALL STUDS BY LL: TIGARD OR 97223 NEW METAL STUDS & BRIDGING 3/A004 GC TO INSTALL 5/8" AS SCHEDULED; BY GC V TYPE'X' GYP. BD.AS AREA: 621 SF 1 LAYER OF 5 8"GYP. BD. ON NEW METAL STUDS & BRIDGING REQUIRED TO BOTH SIDES OF NEW METAL STUDS \ rAS SCHEDULED; BY GC RE ACHIEVE FI o- TO 6 ABOVE FINISHED CEILING V, U 3/4 THK. FRT PLYWD BLOCKING; RATIN SHEET TITLE: w G. w U U ❑ 3/4"THK. FRT PLYWD BLOCKING; � ❑ EXACT LOCATION REQ'D TO BE j w EXACT LOCATION REQ'D TO BE j w VERIFIED IN FIELD. PARTITION TYPES CSC VERIFIED IN FIELD. BASE AS SCHEDULED 18 GA.BOTTOM TRACK WITH 18 GA.BOTTOM TRACK WITH BASE AS SCHEDULED HILTI"X-U" FASTENERS AND R36 HILTI"X-U"FASTENERS AND R36 n FRAMING DETAILS DISCS AT 24"O.C., MAX. DISCS AT 24"O.C., MAX. ❑ ❑ (ICC#-ESR-2269) El (ICC#-ESR-2269) PAINTABLE FIRESTOP BASE AS SCHEDULED SEALANT PROJECT NO. 13-1802 2 3 EXIST. CONCRETE SLAB EXIST. CONCRETE SLABrL--,-_ EXIST. CONCRETE SLAB SCALE: N.T.S. NEW NON-RATED IN PARTITION NEW NON-RATED CHASE PARTITION EXISTING 1-HR RATED DEMISING WALL 3 5/8"GWB ON BOTH SIDES OF 20 GA.3 5/8"METAL STUDS @ 16"oc 2> 5/8"GWB0N ONE SIDE OF 20 GA.3 5/8"METAL STUDS @ 16"oc W/ 1 EXISTING 6"METAL STUD DEMISING WALL W/ 5/8"G Y�PBD.EXTENDED DATE: 04/17/13 W/BRIDGING @ 4'-0"oc;UP TO 6"ABOVE FINISHED CEILING. BRIDGING @ 4'-0"oc;EXTEND GWB TO 6"ABOVE FINISHED CEILING. TO BOTTOM OF DECK ABOVE BY LL TO REMAIN; STUDS TO BE DIETRICH'PRO STUD'(ICC#-ER0171 OR EQUIVALENT). STUDS TO BE DIETRICH'PRO STUD'(ICC#-ER0171 OR EQUIVALENT) GC TO VERIFY THAT EXISTING DEMISING WALLS ARE 1 HR RATED. IF NEW WALL TO ALIGN WITH EXISTING WHERE APPLICABLE.GC TO NOT G.C.SHALL UPGRADE AS REQUIRED. G.C.TO PAINT EXISTING DRAWN BY: KJI ENSURE SMOOTH,SEAMLESS TRANSITION. GC TO PROVIDE FIRE-RETARDANT BLOCKING IN NON-FIRE RATED GYP.BD.AS PER FINISH SCHEDULE&MAINTAIN FIRE RATING. PARTITION FOR ALL WALL-MOUNTED FIXTURES. GC TO PROVIDE FIRE-RETARDANT BLOCKING IN NON-FIRE RATED NO BLOCKING IN FIRE-RATED DEMISING WALLS. REVIEWED BY: AD PARTITION FOR ALL WALL-MOUNTED FIXTURES. SHEET NO. PARTITION TYPES 2 NTS <enne' '. ar Architecture Urban Planning Store Design 360 Lexington Avenue Mixed-Use New York,NY10017 Retail Development www.kennethpark.com MEP Consultant y t ilk� e�� � � k Z i Y /a � \ ��`�1 6 1s� $s %P a< z 101 STOCK ROOM 100 SALES AREA don penn a consulting engineer 635 Westport Parkway I I Suite 300 Grapevine,Texas 76051 Phone:817-410-2858 Fax:817-251-8411 41'-8" SEAL: I HEREBY CERTIFY THAT THIS DRAWING 15-3" I 4-3 10 2-2 WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED/LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF OREGON L'OCCITANE,SPACE #H6 ARCHITECTURAL REG. #: 3721 LEVEL 2 OF 2 I I REGISTRATION EXPIRES : 6/30/2013 I _ . - ► ' Co —w1AA�CEhT F TRAV L= 19'-9" — ,® v o ®010� _ - --- I - -- — ,i 44"MIN. CL =I NNW ,- '":<":^r.cIV U 00 „sw. .....,... / ..,a! H. '�>r.r r. .:F: ..:.. XE. .t. a r• i ... n 5,x.,, F c .. :.r.s ,a ,.,v.: s>i r•a!: .y..:a..,H „r....s,....... ,r,:as,s.. ..::/, �4,,.. .. ,. ..a /.. `a•... ,f ,. .,w.5 ...,,,,i>,.,,.,,,. ts,fr, .r„, .,„„-}..,.,.,,a,.,,,. .,.,' c'r„d.>�,..s,,.sa,,, r:' s .!.{. ..,. .s.-. � 5 a' , �a ...�z ,r ., ,., ,.x ,,.,,,..... ..!✓.sr',.wr,.,. .,.,....s,s,.,G.?.,.M',,.....,,,.. s.,.. ,,..., „/r, r ..,1r .:..er<[ ...,s, .:rc s, ,., .... ....,... ...:.:.,. r,^...E's/./ r < ,. ,rcc. ..<./. , :H'e .:::.... .., ,r•,a ,r:,:-,. �.., r, ,.. ,.. ,.,a:,., ,...sr',r,r,».,,.... r..r. .., .., ,,>,.,.,...,. /.... ... r ,,: z•. .r, ,. k 3, .:x .�.„s :. :•:; ..... ,H'. !.]Y/... a,rF .. ,.y 3..,.. :.. T. r: ..,.:..:. /;/:. u cx,,._6.,r,,,i^ :.s:,. .^-.:,:.,..,.. !': ..., a, .,..., t3 .e.,, rs.. ,.. __.:.. r.: '.{,r-'>r"s:.,, ,..,rs / ;;,,.;3.:,fG. r. 3✓ ... .. : G /-�{ 0� .a,usx5i! ,'x/ fly,'r.o.. /. li,A n S. ,s.l...f.:� /••5 .... ?'r'^f ..•<., y"''.,.x .k 5 < -.:. ,[ Y _;,_', i- \P i .�2 :<s', ./y✓.ss:�.� .Y/,/,/ s1.7/.a ,4:<.Y <.;�F3i/. .,H✓r f s },. / O Xv �t}! x - - 44I I MIN. CLR. .., - - .. ,_. ,....,.,✓. n.,.,, r.,,s r,u.✓,;r,.5. of,s 5,!%'. ,. t> 'f i.H : ,.5.,.3� ,.„.,Z`.j,,,,,;�.,,,,. ,,,s_.�, b /`s, a,. s ,�„ ,,,,.,r.. - � I Co 0 ,<.,3#•, r:. :r.. a.., „... ,n.ri, .<. ., ,,.,„. <4,,.. ..,..,..h3r[ .:.: ,,:./r. x G:f:e��a-/r,s:t:.,..e, r/., :' .-„/',rx,.,,%,.>:»..x,.,.,.F-:., ori :,f.: I 'i 4.../ .>Fi ,:” ,, r. ./ .; :/ YF,'>'/.m Yc;...<..¢ ✓/,'/ Y/ ':'N' '' .... - -. D..v ,s-,s /.. .:,,,: ,...,<s,• ^ ,,,,r.r,s.,6HiE,.,,.5 a. ,,.,,.,./f.., r... '''r sk r s. - ,.,r ,. .. ,:.. :9,s+x' •:r,3.,,,Hr«a�':..f-:.,,r.,;<.x ;. >:. i.f::::s b: „ ,x!:,<,s,.€.„ 1><. '`fir r s�:.:� Ms's `.;.. f.$ rc,:i�>f, `s.. Yrfi.�i'r. 5' x! nyu'� � � - __r.. y•:�: .gi.�''<: .... �Y??.., r�#,,, .Y,.:.��i:f4. ., Yrs :..3� f 6 r3,r':. ?.sy;;s}Ilz/,sr:.a>.,('',:/,i'r%!�9 zs�rr�x fy SsH? ';3„„,.H ,,,:.:.9Yr,' a�,:.`s`.trnNjw'`„,,i`,`:`i1F s F..<-'..,s�>.rJ>,:l.';E.ss.. ./...., i:>s, r ✓-',�5/rr':s :<f"�Es#3✓A:i/✓frbjs9..^': y y�//'h�,•LA-E':' L�j',{FF�`�.sii�a''S ' . 00 � N 00 3 � •r , � 00 MAX. L NGTH OF T_R— VEL— =46,-p3 nor, SO I, � _ MAY 0 2 2013 Q 10 000 zr ” 100 ®®{ ir,a6rw - - ---- ------ 360 ✓53p” .. :.,a✓�, aMIiyf/i:;i r /sari✓3:c «zYst3<st "' '�Fs,. ' : -'�✓r. ✓p k`r F , ...c:',?X ...s .. s ,Ni>;�i'. <.a ,.a ,t»: :?. � rf: ..� ; ;. 3”, 00 F s rf ys� fix, r iR 5 TYPE 2-A.I OBC FIRE EXTINGUISHER TO BE ✓ .l '' s / }sr,y„u .rr'<7.0 a wr r, ., NO ;110� 'r ,^> ,kms/ PROVIDED PER NFPA 10.4.1 &CHAPTER ' 02-13ISSUE FOR LANDLORD & PERMIT5 EXTINGUISHER LOCATION PER NFPA 05 {. � ANNEX E.3.2. ,Hx3 x:> 'H': { �. / ,r>,./:�6//.� '.S`<'.x:.,,.„^.;.., i'� ,.![..,.... ,.,.£.:: :. 3.i.,.3 .� .sa,...a^.. ,- <� ....... ..,:. ...,.. ,,,j//?�h a„. .3..3 �%./y; >” -19-13 - l:r ., hn1 Fyr//x/Wx x>✓/' vY hE 's3 rl'xa, k .. 0 " ' / cEsat� 5 t {:hs r/✓a,' 6 y xs pak r £s _ {. ._ R D1<°" � � ✓�, k�,� � ,� �� � �, NOTE:PER NFPA 10:6.2.1.1,TYPE 2-A FIRE 04 19 13 PRELIM PACKAGE ISSUE �3r 3s� EXTINGUISHER COVERS 11,250 SF FLOOR Mai'3N 7/iJs1-xr'S 3/;i}•'x p# 5/�s€H 5 1l•Yis/in I: </ '. . D DATE REVISIONSAREA.PROVIDED COVERAGE: 11,250 -r,w;3✓ 5 ''.. x :p h.& £x �,s zt s ti �: �tx<: n Sl ', nY y� F>607SF REQUIRED COVERAGE, ,9 >r{x.a"�> r•>>u > u ...,,,„ „!.x.....,,^DY.3 ,>t ,,, "^..,r t., :�'9.,........... ..,x Z.. Sa.. .>,. THEREFORE 3,c SIZE TYPE 2-A EXTINGUISHER.r3°ti"'It,`Fb,_ 3 .fit, ;3.3'h�E�yr x 3 .� ksz'>s:.s „� .�,: .3 Y3::• v / y� { a•:.x ISUFFICIENT. IS x s a.>rrs„u<,..,.,rre.<...s..�,..s.a•,w..ts,.,.,_...v,.[>.u, ......w,�.....u,..L,».>�>.,h'..,,:f,5..w�.,,.s.�r.w...�7<.,,.<>x<r.�.<«�.✓ .:srz.�r�""..>.we..r.t Y ✓r : ,.. �xs���� �� �k r�6� rst xky�xy c.✓ yt m��:!�ss,£�.�/>S px4 £#�lx�s 12'� NOTE: EXISTING CONDITIONS is �' � gH!p � �� r; Y s"�3 R •H.<} & ry?:E�/.!ssF s"'r�osZ� r /"xH'rsr r'%'r.5r/rAi GC TO FIELD VERIFY ALL DIMENSIONS AGAINST LOD. »> a 3 NOTIFY ARCHITECT IMMEDIATELY OF FINDINGS. •,Gxr,e�.< {x.� '( 3u Hr,.Ye 4 A>Yk>.✓ r7 ' E'j y5. ' a f a, ,xxat, NIJKU',T }tal faa £pt ; # ; �p)� /5 SITE PLAN 4 EGRESS PLAN 1 y;a ss a F fxF x y I ��3 a��a�� ��x', ,,., ,s ,�./y�}ktj)��FpS����`o�� -,✓,,a .,.,„..x>��i.�s.<��..�.;::..,,.w.,,,, L'OCCITANE 1/4 ” = 1'-0" SPACE #H6 LOCATION: 1. PROVIDE 80"HEADROOM FROM THE WALKWAY SURFACE TO ANY OVERHANGING BUILDING DATA: OBSTRUCTION. A. CONST. CLASSIFICATION: TYPE II-B 2. HEADROOM OF 80"MINIMUM SHALL BE MAINTAINED FOR WALKS, CORRIDORS, B. OCCUPANCY CLASS: MERCANTILE 10 AISLES, ETC. C. SPRINKLER SYSTEM: FULLY SPRINKLERED SEN PROVENCE D. TOTAL (LEASE) AREA: 621 SQ. FT. 3. OBSTRUCTIONS WITHIN THE WALK PATHWAY (i.E POLES OR FIRE HYDRANTS SHALL E. TOTAL (OCCUPIABLE) AREA: 576 SQ. FT. BOUTIQUE #O57 PROVIDE A 36"MIN. CLEAR WIDTH TO THE EDGE OF THE WALK. SALES (NET) AREA: 442 SQ.FT. WASHINGTON SQUARE MALL 4. PROTRUDING OBJECTS WITH LEADING EDGES BETWEEN 27"AND 80"ABOVE THE STOCK (NET) AREA: 134 SQ.FT. SPACE #H6 FINISHED FLOOR SHALL NOT PROTRUDE MORE THAN 4"INTO WALKS,CORRIDORS, F. TOTAL OCCUPANCY LOAD: 15 PERSONS TOTAL ETC. SALES (NET) AREA (442 SF): 14 PERSONS @ 30 SF/PERSON 9585 SW WASHINGTON SQ. RD. STOCK (NET) AREA (134 SF): 1 PERSONS @ 300 SF/PERSON TIGARD, OR 97223 5. OBJECTS WITH PROTRUDING EDGES LESS THAN 27"ABOVE THE FINISHED FLOOR MAY PROTRUDE ANY AMOUNT. G. # OF EXITS REQUIRED: (1) REQ'd / (2) PROVIDED H. TOTAL EMPLOYEES: 3 PER SHIFT AREA: 621 SF 6. FREE STANDING OBJECTS MOUNTED ON POSTS BETWEEN 27"AND 80"ABOVE THE I. HANDICAPPED TOILET: (0) REQUIRED/ (0) PROVIDED FLOOR MAY PROJECT A MAXIMUM OF 12". SHEET TITLE: 7. FREE-STANDING SIGNS WHERE THE BOTTOM EDGE IS AT OR LESS THAN 80''ABOVE EGRESS THE FINISHED FLOOR SHALL HAVE THE EDGES ROUNDED OR EASED WITH A MIN. RADIUS OF 1/8". SECTION 1015.1 & ACCESSIBILITY 8. ABRUPT CHANGES IN LEVEL OF 4"OR MORE ADJACENT TO WALKS, EXCEPT SPRINKLED BUILDINGS; BETWEEN WALKS AND ADJACENT STREETS OR DRIVES,SHALL BE IDENTIFIED BY 6" HIGH WARNING CURBS ABOVE THE WALK SURFACE. TRAVEL DISTANCE SHALL NOT EXCEED 250 FT. PROJECT NO. 13-1802 NOTE: PRIOR TO STOCKING THE STORE,THE FOLLOWING SHALL BE COMPLETED IN ORDER: ALLOWED TRAVEL DISTANCE = 250FT. ACTUAL TRAVEL DISTANCE GROUND FL. = 57-2"" SCALE: 1/4 = 1'-0" A. A COMPLETED SAFE PATH OF TRAVEL IS PROVIDED TO INSIDE THE BUILDING. B. THE INSIDE SHALL BE COMPLETED AND SIGNED OFF BY THE BUILDING INSPECTOR EXIT DOORS DATE: 04/17/13 C. THE FIRE DEPARTMENT PROVIDED A RELEASE FOR STOCKING SHELVES ACTUAL ACTUAL#OF PEOPLE THRU EXIT DOOR DRAWN BY: KJ e ALLOWED ALLOWED#OF PEOPLE THRU EXIT DOOR D. THE BUILDING INSPECTOR HAS THE FINAL WORD IF IT WILL BE SAFE FOR EMPLOYEES REVIEWED BY: AD TO STOCK SHELVING IN A CONSTRUCTION SITE. .2 PER PERSON SHEET N0. NOT USED 5 HAZARD & EGRESS NOTES 3 BUILDING & EGRESS INFO. 2 N.T.S. N.T.S. _._._._ __-___ _.___.___.. I_ _ __. - ___ __.__- _ _ _ - _._ _._ 1. NO IMPROVEMENTS SHOULD BE INSTALLED DURING INCLEMENT WEATHER.TIE-IN OF 1. ALL HOT WORKS MUST BE PRE-APPROVED BY THE CENTER MANAGER OR F. DAMAGE REPAIR PRECONSTRUCTION REQUIREMENTS FIRE ALARM SIEMENS BUILDING TECHNOLOGIES, INC. FLASHING MATERIALS TO MOIST OR DUSTY SURFACES SHOULD NOT BE ATTEMPTED. OPERATIONS MANAGER. TENANT'S CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR REPLACEMENT JEFF NEELY "" ° EXISTING MATERIALS, AS WELL AS ALL METAL OR CONCRETE SURFACES,SHOULD BE 0.SLAB PENETRATION /STRUCTURAL SUPPORT OF ANY DAMAGES CAUSED BY TENANT'S CONTRACTOR OR HIS SUBCONTRACTOR TO PRIOR TO ENTERING THE PROJECT OR COMMENCEMENT OF CONSTRUCTION, ALL TEL: (503) 234-9995 ken H eth pd. k CLEANED PRIOR TO APPLICATION OF NEW MATERIALS. 1. NO PENETRATIONS OR SAW CUTTING MAY BE MADE THROUGH SUSPENDED SLAB-IF THE CENTER OR SURROUNDING TENANTS. ALL DAMAGE MUST BE REPAIRED WITHIN A (24) TENANT CONTRACTORS MUST SCHEDULE A PRECONSTRUCTION MEETING WITH THE ti 2. THE IMPROVEMENTS SHOULD IN NO WAY DIMINISH OR INTERFERE WITH THE APPLICABLE-WITHOUT MANAGEMENT APPROVAL AND NOTIFICATION OF DATE HOUR TIME PERIOD, OR THE LANDLORD WILL COMPLETE ALL NECESSARY REPAIRS AT THE TENANT COORDINATOR AND/OR OPERATIONS MANAGER AND PROVIDE THE STRUCTURAL INTEGRITY OF THE BUILDING, ROOF STRUCTURE, OR WITH ROOF AND TIME. X-RAYS OF THE AREA OF THE PROPOSED FLOOR OPENING MUST BE TAKEN SOLE COST AND EXPENSE OF THE TENANT'S CONTRACTOR, PLUS A TWENTY-FIVE PERCENT FOLLOWING: DRAINAGE. BEFORE CENTER MANAGEMENT APPROVAL. A QUALIFIED X-RAY CONTRACTOR (25%) SURCHARGE. 1. A FULL SIZE SET OF LANDLORD-APPROVED PLANS. Architecture 3. NO IMPROVEMENTS SHOULD BE INSTALLED IN ANY ROOF WATERWAY OR AREA OF HIRED AT GENERAL CONTRACTOR'S EXPENSE SHALL PERFORM ALL X-RAYS. G. CONSTRUCTION NOISE 2. EVIDENCE OF TENANT'S BUILDING PERMIT AND THE BUILDING DEPARTMENT Urban Planning THE ROOF WHICH PONDS WATER. 2. CENTER MANAGEMENT OFFICE APPROVAL SHALL NOT RELIEVE CONTRACTOR FROM ANY WORK INCLUDING, BUT NOT LIMITED TO,SAW CUTTING, BORING OR DRILLING THAT APPROVED SET OF PLANS. Store Design 4. ALL ELECTRICAL CONDUIT, METAL PIPE, OR PLASTIC PIPING SHOULD BE RESTRAINED RESPONSIBILITY FOR DAMAGE TO MACERICH PROPERTY AND/OR ANY TENANT'S CREATES EXCESSIVE NOISE LEVELS OR VIBRATION,SHALL BE PERFORMED DURING 3. A COMPLETED COPY OF THE "PRECONSTRUCTION MEETING INFORMATION SHEET," 360 Lexington Avenue TO APPROPRIATELY SIZED AND APPROVED ROOF SUPPORTS SET INTO ROOFING PROPERTY DUE TO PENETRATION OR SAW CUTTING OF THE FLOOR SLAB. NON-MALL HOURS.THIS IS TO ENSURE THAT NEIGHBORING TENANTS AND PASSING FOUND ON THE LAST PAGE OF THESE RULES AND REGULATIONS, MUST BE SUBMITTED FIRE SPRINKLER SYSTEM WYATT FIRE PROTECTION, INC. Mixed-Use New York,NY10017 CEMENT. ATTACHMENT TO BLOCKING SHOULD ALLOW FOR MOVEMENT DUE TO CONTRACTOR SHALL COORDINATE WITH THE CENTER MANAGEMENT OFFICE WHEN CUSTOMERS ARE NOT DISTURBED. A FINE WILL BE IMPOSED FOR EACH VIOLATION.* TO BOTH CENTER MANAGEMENT AND THE TENANT COORDINATOR. KEN SUTHERLAND Retail Development www.kennethpark.com THERMAL EXPANSION AND CONTRACTION. ANY CORE BORING OR SAW CUTTING OF THE FLOOR SLAB IS ATTEMPTED,AND I. PRELIMINARY CONSTRUCTION POWER USAGE 4. A CERTIFICATE OF INSURANCE VERIFYING MINIMUM COVERAGE AS SPECIFIED IN TEL: (503) 684-2928 5. PROVIDE NEW PREFABRICATED LEAD OR METAL PIPE SLEEVE FLASHING TO SEAL ANY PROVIDE A WATCHMAN IN THAT SPECIFIC ARE BELOW THE TENANT SPACE,WHERE PRELIMINARY ELECTRICAL FACILITIES FOR CONSTRUCTION POWER MAY BE AVAILABLE EXHIBIT B. PRIOR TO COMMENCING CONSTRUCTION,TENANT'S CONTRACTOR MUST NEW PIPE PENETRATIONS THROUGH THE ROOF. FLASHING FLANGES SHOULD BE CORE BORING WILL OCCUR FOR THE DURATION OF SUCH WORK. FROM LANDLORD.TENANT'S GENERAL CONTRACTOR MUST PROVIDE TEMPORARY HAVE INSURANCE APPROVED BY MACERICH TENANT COORDINATION IN THE MEP Consultant f a_3':t M� ; Gf .t;i? p A 3;?.vi.s .<':'::$ 33f:: Y REQUIRED COVERAGE AMOUNTS AND VERBIAGE SPECIFIED AND rF:".'"h" ,::..>:f,Y,. .t.,...fy s.>,...f"._.,,s2.,.",'R U O GE ASS CIF D IN EXHIBIT B A v:.4": .. r..r ..., . . .. " . , :.. _ „ .Y ,r. .. ..d"y". .. SEALED IN A MANNER ACCEPTABLE TO THE ROOFING MANUFACTURER. 3. LANDLORD DOES NOT ACCEPT RESPONSIBILITY FOR WATER VAPOR EMISSIONS FACILITIES FROM TENANT'S PANEL AND MAKE APPLICATION FOR ELECTRICAL SERVICE TO Q r ;Y � g < 5N - ry s � 4b°. r; 6. AT AREAS WHERE ELECTRICAL CONDUITS OR OTHER ROOF PENETRATIONS ARE THROUGH THE SLAB THAT MAY EXCEED FLOORING MANUFACTURER'S THE SERVING UTILITY COMPANY, IF APPLICABLE.THIS SHOULD BE THE FIRST ITEM EXHIBIT C OF THESE RULES & REGULATIONS. IF A CRANE OR HELICOPTER WILL BE � r k °' � �s REMOVED, THE ROOF DECK MUST BE REPAIRED TO ITS ORIGINAL CONDITION OR RECOMMENDATIONS OR WHICH MAY OCCUR AS A RESULT OF SAW CUTTING OF ITS ACCOMPLISHED FOR CONSTRUCTION POWER PURPOSES.WHEN PRELIMINARY USED DURING CONSTRUCTION, HIGHER EXCESS UMBRELLA LIABILITY COVERAGE _ q g ,y BETTER, AND BE FREE FROM OPEN PENETRATIONS. SLAB BY TENANT OR ITS CONTRACTOR St. SHOULD TENANT CHOOSE TO SAW CUT ELECTRICAL SERVICE IS PROVIDED, A CHARGE BASED OFF OF GROSS LEASABLE AREA OF AMOUNTS APPLY, AND ARE DETAILED IN EXHIBIT B. NO CONTRACTOR WILL BE 1. _ � "i" R. FIRE PROTECTION THE CONCRETE SLAB FOR PLACEMENT OF CONDUITS, PLUMBING PIPING OR OTHER THE DEMISED PREMISES, SHALL BE PAID BY TENANTS GENERAL CONTRACTOR TO PERMITTED TO START WORK UNTIL THE REQUIRED INSURANCE CERTIFICATE IS ON FILE BUILDING ROOFING BOB CARLSON ROOFING, INC. `" ., 1. ALL FIRE SPRINKLER WORK WITHIN TENANT'S SPACE MUST BE PERFORMED BY A UNDER SLAB ITEMS, THEN TENANT OR TENANT'S CONTRACTOR MUST REPAIR THE LANDLORD AT PRECONSTRUCTION MEETING.** WITH THE LANDLORD. BOB CARLSON LANDLORD-APPROVED FIRE SPRINKLER CONTRACTOR.ALL WORK SHALL BE THE CRUSHED ROCK, VAPOR RETARDED AND SLAB IN ACCORDANCE WITH LANDLORD'S 5. PROGRESS SCHEDULE OR BAR CHART SHOWING THE WORK SCHEDULE AND TEL: (503) 640-3623 don pens consulting engineer TENANT'S SOLE COST AND EXPENSE. SPECIFICATIONS. J. DELIVERIES ANTICIPATED COMPLETION OF TENANT'S WORK. Westport Parkway Suite 300 2. IN THE EVENT OF A BROKEN SPRINKLER HEAD OR LINE, PLEASE NOTIFY CENTER 4. ALL PENETRATIONS ARE TO BE PROPERLY SEALED WITH EXPANDING FOAM, FILLED 1. ALL DELIVERIES ARE TO BE MADE DURING OFF MALL HOURS.ANY OTHER DELIVERY 6. A 24-HOUR, EMERGENCY TELEPHONE NUMBER FOR THE GENERAL CONTRACTOR, Suite MANAGEMENT IMMEDIATELY. WITH CONCRETE FILL, AND FIRE STOPPED, OR AS APPLICABLE PER BUILDING TIME MUST BE PRE-APPROVED BY MALL MANAGER OR OPERATIONS MANAGER.A PROJECT MANAGER,SITE SUPERINTENDENT, AND FOR ALL MAJOR Grapevine,Texas 76051 3. AT NO TIME WILL THE SPRINKLER SYSTEM BE SHUT DOWN WITHOUT FIRSTN OTIFYING CODE(S). FINE WILL BE IMPOSED FOR EACH VIOLATION.* SUBCONTRACTORS. I Phone:817-410-2858 THE CENTER MANAGEMENT OFFICE. ANY WORK REQUIRING DRAINING THE FIRE 5. NOTHING IS PERMITTED TO BE ATTACHED TO, OR SUSPENDED FROM, OR PENETRATE 2. DELIVERIES MUST BE MADE THROUGH REAR DOORS AT ALL TIMES. EXCEPTIONS ARE 7. A COMPLETE LIST OF SUBCONTRACTORS AND SUPPLIERS,THEIR ASSOCIATED TRADE, Fax:817-251-8411 SPRINKLER SYSTEM MUST BE PERFORMED MONDAY THROUGH FRIDAY BEFORE THE ROOF DECK ABOVE. TENANT'S CONTRACTOR IS REQUIRED TO FRAME, BRACE 4' X 12' DRYWALL, LONG METAL OR WOODPIECES THAT CANNOT BE MOVED CONTACT AND PHONE NUMBERS.THE GENERAL CONTRACTOR AND ALL � CENTER OPENS. CONTACT CENTER'S SECURITY PRIOR TO ANY WORK ON THE FIRE AND/OR SUSPEND, AS NEEDED TO/FROM THE TOP CHORD OF JOISTS OR THROUGH SERVICE CORRIDORS, OR SPACES WITHOUT REAR DOORS .THESE ITEMS SUBCONTRACTORS MUST BE BONDABLE AND MEET ALL LICENSING AND INSURANCE SEAL: SPRINKLER SYSTEM. A MINIMUM TWENTY-FOUR (24) HOURS NOTICE OF INTENT MUST STRUCTURAL STEEL WHICH EXIST ABOVE TENANT SPACE. MUST BE DELIVERED BEFORE 9:30 A.M. CONTRACTOR IS RESPONSIBLE FOR REQUIREMENTS BY THE STATE AND CITY WHERE THE WORK WILL OCCUR. (SEE ELECTRICAL PORTLAND GENERAL ELECTRIC CO. I HEREBY CERTIFY THAT THIS DRAWING BE GIVEN TO LANDLORD PRIOR TO PERFORMING THE ABOVE MENTIONED WORK. P. ELECTRICAL CLEANING UP ANY TRACKED DUST OR DEBRIS ON MALL FLOORS AFTER DELIVERY IS ATTACHED EXHIBIT A.) TIFFANY RITCHEY WAS PREPARED BY ME OR UNDER MY REFER I E EACH VIOLATION. 8. PAYMENT OF ALL LANDLORD REQUIRED FEES I.E. BARRICADE TEMPORARY POWER TEL: (503) 228-6322 TO MALL SPECIFIC RULES AND REGULATIONS ADDENDUM FOR NOTICE OF 1. FOR ALL WORK IN LANDLORD'S SWITCHGEAR GENERAL COMPLETED. A FINE WILL BE IMPOSED CH , oR s swlTc G (SES),TENANT'S G ( INTENT REQUIREMENTS. DRAINAGE REQUIRED BY TENANT WILL BE PERFORMED BY THE CONTRACTOR MUST CONTRACT WITH A LANDLORDAPPROVED ELECTRICAL 3. UNDER NO CIRCUMSTANCES WHATSOEVER ARE THE MALL ENTRY DOORS TO BE DUMPSTER,SPRINKLER SHUTDOWN, BARRICADE SIGNAGE, ETC.) AS OUTLINED IN THE DIRECT SUPERVISION AND THAT I AM A FOR FINAL CONNECTIONS: DULY REGISTERED/LICENSED ARCHITECT LANDLORD'S CONTRACTOR, UPON RECEIPT OF SPRINKLER SHUT DOWN FEE CONTRACTOR, AT TENANT'S SOLE COST AND EXPENSE.ALL WORK SHALL BE USED FOR MOVEMENT OF CONSTRUCTION MATERIAL OR EQUIPMENT. "PRECONSTRUCTION MEETING INFORMATION SHEET." ADAM ETHCONN ON UNDER THE LAWS OF THE STATE OF PAYMENT BY GENERAL CONTRACTOR. IT IS ASSUMED THAT THE GENERAL PERFORMED DURING OFFHOURS, AND NO ONE WILL BE PERMITTED TO WORK ON 4. LOADING BAYS AND TRUCK COURTS ARE TO BE USED FOR LOADING AND 9. A $5,000 (FIVE THOUSAND DOLLAR) DEPOSIT, IN THE FORM OF A BANK OR CERTIFIED TEL: (503) 639-4627 OREGON CONTRACTOR WILL REQUIRE A MINIMUM OF TWO 2 SPRINKLER SHUT DOWNS FOR WIT WHILE UNLOADING ONLY. ANY VEHICLE LEFT UNATTENDED WILLBE TOWED AWAY AT CHECK OR AS SET FORTH IN THE LEASE DOCUMENT WILL BE REQUIRED OF THE ( ) SWITCHGEAR LE ENERGIZED. , ( ) Q THE BUILD-OUT.SUCH FEES WILL BE COLLECTED DURING THE PRECONSTRUCTION 2. ALL ELECTRICAL CONTRACTORS MUST GO THROUGH CENTER MANAGEMENT OWNER'S EXPENSE. A FINE WILL BE IMPOSED FOR EACH VIOLATION.*CONTRACTOR TENANT'S GENERAL CONTRACTOR AT THE TIME OF JOBSITE CHECK-IN TO ENSURE ARCHITECTURAL REG. #: 3721 MEETING. FEES FOR ADDITIONAL SPRINKLER SHUT DOWNS MUST BE PAID PRIOR TO OFFICE AND/OR THE OPERATIONS MANAGER FOR ACCESS INTO ELECTRICAL PERSONNEL ARE TOPARK ONLY IN AREAS DESIGNATED BY THE OPERATIONS PAYMENT OF ANY DAMAGES TO FACILITIES OR MALL LABORERS REQUIRED TO REGISTRATION EXPIRES : 6/30/2013 THE WORK BEING PERFORMED. ROOMS AND WILL BE RESPONSIBLE FOR REPLACING ALL PANEL COVERS AFTER USE. MANAGER OR CENTER MANAGER. A FINE WILL BE IMPOSED FOR EACHVIOLATION.* REPAIR DAMAGES.THIS DEPOSIT WILL BE RETURNED AFTER COMPLETION OF PUNCH NATURAL GAS NORTHWEST NATURAL -----, 4. SPRINKLER HEADS AND ALL FIRE PROTECTION COMPONENTS ARE TO REMAIN 3. ELECTRICAL CONTRACTOR SHALL SUBMIT TO THE LANDLORD A SCHEDULE OF WORK 5. AT NO TIME WILL HARD CAST STEEL WHEELS BE ALLOWED TO CROSS MALL LIST ITEMS AND CLOSE OUT DOCUMENTS HAVE BEEN RECEIVED (LESS COST OF TEL: (503) 226-4211 OPERABLE DURING CONSTRUCTION, INCLUDING SMOKE DETECTORS (EXCEPT AFFECTING THE MALL'S METER SWITCHBOARD.THE SCHEDULE SHALL IDENTIFY THE FLOORING. A FINE WILL BE IMPOSED FOR EACH VIOLATION.* DAMAGES AND/OR UNPAID FINES WHERE APPLICABLE) WITHIN LANDLORD DURING SYSTEM MODIFICATION DOWNTIME). EXTREME CAUTION AND AWARENESS ESTIMATED TIME OF WORK IF ANY),).POWER OUTAGES AND THE DESCRIPTION OF K. TRASH REMOVAL PRESCRIBED TIME FRAME. „1 "., ��� MUST BE UTILIZED AT ALL TIMES. CAUTION SHOULD BE USED WHEN WORKING NEAR THE WORK TO BE DONE. 1. THE TRASH FROM ANY REMODEL OR BUILD-OUT IS THE RESPONSIBILITY OF THE 10. MATERIAL SAFETY DATA SHEETS (MSDS) ON ALL HAZARDOUS SUBSTANCES USED BY I 4..�- - PRESSURIZED LINES OR HEADS. 4. UPON APPROVAL OF THE ABOVE SCHEDULE BY THE LANDLORD, THE ELECTRICAL GENERAL CONTRACTOR.SOME PROPERTIES MAY HAVE A DESIGNATED TRASH ANY CONTRACTOR MUST BE PROVIDED TO LANDLORD 48 HOURS PRIOR TO THE 5. ANY FIRE PROTECTION SYSTEM IMPAIRMENT, INCLUDING THE TEMPORARY CONTRACTOR MAY PROCEED WITH HIS WORK.ANY VARIATIONS IN THE SCHEDULE REMOVAL SERVICE THAT THE GENERAL CONTRACTOR WILL BE REQUIRED TO USE. START OF WORK INVOLVING THE HAZARDOUS SUBSTANCE. l ����e :� COVERING OF SMOKE DETECTORS, REQUIRES THE FORMAL NOTIFICATION OF THE MUST BE APPROVED BY THE LANDLORD. DUMPSTER FEES AND/OR PARKING LOT DUMPSTER RENTAL FEE WILL BE ESTABLISHED 11. LANDLORD RESERVES THE RIGHT TO REFUSE THE USE OF ANY SUBSTANCE LANDLORD S } k , it". . r ` PROPERTY'S ALARM MONITORING COMPANY. 5. ANY OUTAGES WILL BE COORDINATED WITH THE MALL MANAGER , LOCAL UTILITY AND CHARGED AT THE PRECONSTRUCTION MEETING.TENANT'S GENERAL BELIEVES MAY BE HAZARDOUS WHEN USED IN THE SHOPPING CENTER. I , - , 1, ®cfr"'�, 6. ANY SPRINKLER IMPAIRMENT, WHETHER PLANNED OR UNPLANNED,WHICH EXCEEDS COMPANY, AND ALL AFFECTED TENANTS FROM THE PARTICULAR METER CONTRACTOR MUST NOTIFY MALL OPERATIONS MANAGER AT LEAST 24 HOURS 12. BOND-LANDLORD RESERVES THE RIGHT TO REQUIRE A PERFORMANCE BOND 0j ��.jrd , OR IS LIKELY TO EXCEED EIGHT (8) HOURS MUST BE REPORTED TO CENTER SWITCHBOARD.THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR TENANT PRIOR TO DUMPSTER PLACEMENT AND DUMPSTER PULLS. MALL OPERATIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.TENANT SHALL OBTAIN OR TELEPHONE/DATA �, .�-f MANAGEMENT, THE ALARM MONITORING COMPANY,THE LOCAL FIRE DEPARTMENT COORDINATION, SAFETY DURING THE PERFORMANCE OF WORK,AND THE MANAGER WILL ESTABLISH THE LOCATION OF DUMPSTER PLACEMENT IN THE CAUSE ITS CONTRACTOR TO OBTAIN PAYMENT AND PERFORMANCE BONDS .1 .. AND ALLIANZ IMMEDIATELY. AVOIDANCE OF ANY UNSCHEDULED SHUTDOWNS OF MALL POWER. PARKING LOT. ALL DUMPSTER FEES ARE TO BE PAID AT THE TIME OF ORDER. NO COVERING THE FAITHFUL PERFORMANCE OF THE CONTRACT FOR THE � -4� k. `;';- S. SMOKE DETECTORS/TESTING 6. AT NO TIME SHALL THE METER SWITCHBOARD BE LEFT UNATTENDED OR THE COVERS EXCEPTIONS! CONSTRUCTION OF TENANT'S WORK AND THE PAYMENT OF ALL OBLIGATIONS �OF '�`' 1. IT IS THE SOLE RESPONSIBILITY OF THE TENANT AND ITS CONTRACTOR TO PROVIDE A ON THE SWITCHBOARD BE LEFT OFF WHILE WORK IS BEING PERFORMED. IT IS THE 2. ANY CONTRACTOR USING THE MALL'S REFUSE CONTAINERS WITHOUT ARISING HEREUNDER.SUCH BONDS SHALL BE FOR THE MUTUAL BENEFIT OF BOTH . SMOKE DETECTOR SYSTEM WITHIN EACH SPACE-AS MAY BE REQUIRED BY RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO MAINTAIN THE AREA WHILE AUTHORIZATION OR LEAVING DEBRIS OR MATERIAL IN COMMON AREAS WILL BE LANDLORD AND TENANT, AND SHALL BE ISSUED JOINTLY TO LANDLORD AND AY 0 2 2013 APPLICABLE CODE(S). AT NO TIME WILL TENANT'S CONTRACTOR BE ALLOWED TO WORKING AND MAINTAIN SAFETY STANDARDS FOR ALL INDIVIDUALS. COMPLIANCE CHARGED A FINE FOR AN ADDITIONAL DUMPING FEE, AND IF DAMAGE OCCURS TENANT AS OBLIGES AND BENEFICIARIES. PRIOR TO THE DATE TENANT COMMENCES TAMPER WITH OR DISCONNECT ANY PART OF THE MALL'S SMOKE DETECTORS. WITH OSHA'S LOCKOUT STANDARD IS MANDATORY. DUE TO CONTRACTOR'S USE, CONTRACTOR WILL BE HELD OBLIGATED FOR ALL CONSTRUCTION OF TENANT'S WORK, TENANT SHALL SUBMIT EVIDENCE INTERFERENCE WITH MALL LIFE SAFETY SYSTEM WLIL AUTOMATICALLY MAKE YOU OR 7. UPON COMPLETION, THE METER SWITCHBOARD SHALL BE CLEAR OF ALL DEBRIS.ALL REPAIRS AND CLEANUP AS THE RESULT OF THAT DUMPING, PLUS A TWENTY-FIVE SATISFACTORY TO LANDLORD THAT SUCH BONDS HAVE BEEN ISSUED.ALL BONDS YOUR COMPANY RESPONSIBLE FOR ANY DAMAGE THAT MIGHT OCCUR TO MALL COVERS AND ASSOCIATED HARDWARE SHALL BE REPLACED IN THEIR ORIGINAL PERCENT (25%) SURCHARGE. MUST CARRY AN INSURANCE RATING OF NO LESS THAN A-VIII.CHECK WITH MALL SEE WASHINGTON SQUARE MALL LOCAL EQUIPMENT. ALL CONNECTIONS REQUIRED BY TENANT OF TENANT'S LIFE SAFETY LOCATION OR POSITION. 3. ALL DISPOSAL OF HAZARDOUS WASTE SHALL BE IN ACCORDANCE WITH ALL LOCAL, OPERATION'S MANAGER FOR ADDITIONAL BOND REQUIREMENTS. UNION SUB-CONTRACTORS DOCUMENT FOR SYSTEM TO MALL LIFE SAFETY SYSTEM MUST BE PERFORMED BY MALL LIFE SAFETY 8. ALL CONDUCTORS ARE TO BE COPPER INSTALLED IN CONDUIT. STATE AND FEDERAL REGULATIONS. ANY CONTRACTOR USING THE MALLS REFUSE 13. COMPLETED, INITIALED AND SIGNED COPY OF THESE CONTRACTOR RULES AND RECOMMENDED LOCAL UNION CONTRACTOR AT TENANTS EXPENSE. 9. KEEP ALL PIPING AS CLOSE TO WALLS AND AS HIGH TO UNDERSIDE OF ROOF CONTAINERS FOR THE DISPOSAL OF HAZARDOUS WASTE WILL BE CHARGED A FINE. REGULATIONS. CONTRACTOR CONTACT INFORMATION. 2. SMOKE EVACUATION / ALARM TESTING FEE: A SMOKE EVACUATION/FIRE ALARM FRAMING AS POSSIBLE. CONTRACTOR WILL BE HELD OBLIGATED FOR ALL CLEANUPS AS THE RESULT OF THAT TEST IS REQUIRED ON THET ENANT'S INSTALLED SYSTEM, IF APPLICABLE CODES APPLY. Q. ROOF ACCESS AND ROOF-RELATED IMPROVEMENTS DUMPING, PLUS A TWENTY-FIVE PERCENT (25%) SURCHARGE. CONSTRUCTION RULES THE FEE FOR EACH TEST CHARGED TO THE TENANT'S GENERAL CONTRACTOR IS 1. ACCESS TO THE MALL'S ROOF IS RESTRICTED TO LANDLORD'S PERSONNEL AND 4. TENANT'S CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO PARKING SURFACES A. QUALITY OF WORKMANSHIP REFERRED ON THE PRECONSTRUCTION MEETING INFORMATION SHEET OF THIS LANDLORD'S DESIGNATED CONTRACTORS ONLY. NO TENANT CONTRACTOR OR CAUSED BY TENANT'S ROLL-OFF TRASH CONTAINER OR STORAGE BOX CONTAINERS. TENANT'S WORK SHALL BE PERFORMED IN A THOROUGH, FIRST CLASS AND MANUAL THESE TESTS ARE TO BE PERFORMED PRIOR TO THE MALLS' OPERATING SUBCONTRACTOR WILL BE PERMITTED ON THE ROOF UNLESS ARRANGED WITH THE TENANT'S CONTRACTOR TO ENSURE EXISTING PARKING SURFACES ARE ADEQUATELY WORKMANLIKE MANNER AND SHALL BE IN GOOD AND USABLE CONDITION AT THE DATE HOURS AND WILL BE CONDUCTED WITH THE LOCAL FIRE MARSHAL SUPPORT STAFF. LANDLORD AND SUPERVISED BY MALL PERSONNEL.TENANT CONTRACTOR PROTECTED. OF COMPLETION THEREOF. IF IN THE LANDLORD'S JUDGMENT,THE TENANT'S WORK IS 3. IF ADDITIONAL MALL STAFF IS REQUIRED TO BE ON SITE DURING A PRELIMINARY TEST ACCESSING THE ROOF MUST CHECK IN AND OUT WITH MALL OFFICE OR A FINE WILL L.SAFETY NOT COMPLETED IN A FIRST CLASS WORKMANLIKE MANNER OR IN COMPLIANCE WITH THAT DOES NOT INVOLVE THE FIRE DEPARTMENT,THE TENANT'S GENERAL BE IMPOSED. 1. TENANT'S GENERAL CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE SAFETY APPROVED PLANS, THE TENANT WILL NOT BE ALLOWED TO OPEN UNTIL SAID 05-02-13 ISSUE FOR LANDLORD & PERMIT CONTRACTOR WILL BE CHARGED FOR EACH TEST.** 2. CONTACT LANDLORD'S APPROVED CONTRACTOR FOR ANY AND ALL ROOF WORK REGULATIONS. TENANT'S CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DISCREPANCIES ARE CORRECTED. T. LANDLORD'S PUNCHLIST WITHIN THE CENTER. (MALL MANAGEMENT OFFICE TO PROVIDE REQUIRED ROOFING TO SAFEGUARD ALL CONTRACTOR PERSONNEL AND THE PUBLIC FROM ACCIDENT, B. WORK COORDINATION 04-19-13 PRELIM PACKAGE ISSUE 1. PHYSICAL REQUIREMENTS: UPON COMPLETION OF THE TENANT'S WORK,THE TENANT CONTRACTOR INFORMATION.) ALL WORK SHALL BE AT THE TENANT'S SOLE COST AND TO PRESERVE ALL PRIVATE AND PUBLIC PROPERTY. LANDLORD RESERVES THE 1. ANY MECHANICAL, ELECTRICAL, OR PLUMBING ITEM WHICH NEEDS TO BE ROUTED OR HIS CONTRACTOR SHALL NOTIFY THE LANDLORD'S TENANT COORDINATOR AND AND EXPENSE. RIGHT TO STOP ALL WORK UNTIL SUCH CONDITIONS OR PRACTICES ARE RESOLVED. THROUGH ANOTHER TENANT'S SPACE MUST BE COORDINATED WITH THE CENTER CENTER MANAGEMENT OFFICE OF THE SAME. WITHIN TEN (I 0) DAYS OF SUCH 3. ROOF AREA MUST BE KEPT CLEAN OF ALL DEBRIS.ALL EXCESS MATERIALS, FLASHING, 2. CONTRACTORS OR SUBCONTRACTORS ARE PROHIBITED FROM CONSUMING OR MANAGEMENT OFFICE AND THE TENANT WHOSE SPACE THE ITEMS WILL PASS 0 DATE REVISIONS NOTIFICATION,THE TENANT COORDINATOR OR OPERATIONS MANAGER SHALL SHEET METAL SCREWS, ETC., MUST BE REMOVED. A FINE WILL BE IMPOSED FOR ANY BEING UNDER THE INFLUENCE OF ALCOHOL OR ANY INTOXICANT WHILE ON MALL THROUGH, ALL AT TENANT'S CONTRACTOR'S SOLE RISK AND EXPENSE AND DURING INSPECT THE PREMISES AND PREPARE A PUNCHLIST OF DEFECTIVE ITEMS, IF ANY. DEBRIS THAT HAS TO BE REMOVED BY THE CENTER MANAGEMENT OFFICE, PLUS A PROPERTY (INCLUDING TENANT'S PREMISES, EATING AREAS, OR VEHICLES PARKED HOURS AND TIMES THAT ARE COMMERCIALLY REASONABLE FOR THE OTHER TENANT. KEY PLAN: SUCH PUNCHLIST SHALL BE PASSED TO THE TENANT'S CONTRACTOR. ALL PHYSICAL TWENTY-FIVE PERCENT (25%) SURCHARGE.*ALL ROOF PENETRATIONS MUST BE ON MALL PROPERTY). SMOKING IS NOT PERMITTED IN THE CENTER.A FINE WILL BE 2. NO CONTRACTOR OR SUBCONTRACTOR PARTICIPATING IN TENANT'S WORK WILL r 111, -j�z„"',�y z � ., z PUNCH ITEMS SHALL THEN BE REPAIRED WITHIN THE NEXT FIFTEEN (15) DAYS. COORDINATED WITH THE OPERATIONS MANAGER 48 HOURS PRIOR TO WORK IMPOSED FOR EACH VIOLATION. AT ANY TIME DAMAGE, INJURE, INTERFERE WITH OR DELAY ANY OTHER �,0 xr y :E r y ' y yk rte.:;" F .. 3r £r�Y Y l r �k 9 /" £:.✓3 T fi'f f f }}.y /r/ f f ' ... N e k aH s :Cx^i Y F f`h 4k /t ,,£r t r� l 5 Y ,� 2. PAPERWORK REQUIREMENTS: UPON APPLICATION TO LANDLORDS TENANT COMMENCING. 3. ROUTINE INSPECTIONS WILL BE PERFORMED BY THE LANDLORDS REPRESENTATIVE, CONSTRUCTION WITHIN THE MALL. , 4 ,p ,-. ," y NF3, £spy 1 y �, COORDINATOR BY THE TENANTS CONTRACTOR FOR THE REFUND OF THE 4. THERE SHALL BE NO PENETRATIONS OF THE ROOF WITHOUT PRIOR WRITTEN OPERATIONS MANAGER OR MALL SECURITY PERSONNEL WITH REGARDS TO 3. ALL REQUIRED TENANTS WORK ON FIRE SPRINKLER, ROOF, AND ELECTRICAL WITHIN ;. -� x x R :: s ��f 5 ter= `�,.":� u x,�;.:soa'>�� s,.,y F�..y {d3%z r s s3:� s CONTRACTOR'S SECURITY DEPOSIT IF ANY),SUCH DEPOSIT SHALL BE RETURNED APPROVAL OF BOTH THE TENANT COORDINATOR AND THE CENTER MANAGEMENT ACCURATE PERFORMANCE OF CONTRACTOR'S WORK, GENERAL SAFETY MALL'S SERVICE ENTRANCE SECTION (SES), MUST BE PERFORMED BY THE LANDLORD = �' �`.00" � �uy 4 's1 1-r 3 ,� ( ) ( ) WITHIN FORTY-FIVE (45) DAYS TOGETHER WITH A STATEMENT OF DEDUCTION, OFFICE. ANY AND ALL ROOF PENETRATIONS REQUIRED BY TENANT SHALL BE AT REQUIREMENTS, AND TO ENSURE ADHERENCE TO THE CONTRACTOR RULES AND APPROVED CONTRACTOR, IF APPLICABLE.THE NAMES AND CONTACT , ,u � .t... � b�M ,�,, 3o -� frb� y, PROVIDED THAT: TENANT'S EXPENSE, AND WILL BE PERFORMED BY LANDLORD'S APPROVED ROOFING REGULATIONS. INFORMATION FOR EACH ARE AVAILABLE IN THE MALL MANAGEMENT OFFICE. !ii �" f� � A. ALL CONSTRUCTION IS COMPLETE INCLUDING ALL LANDLORD PUNCHLIST ITEMS. CONTRACTOR. 4. AT LANDLORD'S REQUEST, CONTRACTOR MUST PROVIDE ADDITIONAL VENTILATION 4. ALL WORK BY THE LANDLORD'S APPROVED FIRE SPRINKLER, ROOFING AND 11 -�, "' {} s .Y 3�rS7•� £a sk1. ..a". t.,,oy a,:. 3 .eau . £h� B. A COMPLETE CLOSEOUT/COMPLIANCE PACKAGE HAS BEEN SUBMITTED TO 5. PRIOR TO INSTALLATION OF NEW MECHANICAL EQUIPMENT,TENANT SHALL HAVE WHEN NECESSARY. ELECTRICAL CONTRACTOR CAN BE SCHEDULED THROUGH THEIR RESPECTIVE .R: L ._ � ; <,yfi„ LANDLORD. S BMITTE LAND S. MISCELLANEOUS SAFETY RULES: REPRESENTATIVE BY THE TENANT'S GENERAL CONTRACTOR. .� _ �. '�xs U D FOR LORD S APPROVAL, HEATING, VENTILATION, AIR �_...` -€ f� w s . C. ALL RUBBISH, DEBRIS, PACKING, STORAGE VESSELS,TRANSPORTATION ITEMS,TOOLS, CONDITIONING DESIGN INFORMATION, COOLING AND HEATING LOADS, AND - FIRE EXTINGUISHER: MINIMUM 20 LB.ABC FIRE EXTINGUISHER TO BE LOCATED ON SITE. 5. ALL PRIOR TENANT IMPROVEMENTS SERVING THE DEMISED PREMISES AND NOT w. `, I,11g 4 E VEHICLES, CONTAINERS AND THE LIKE WHETHER OWNED, LEASED, HIRED OR OFF-HIRED EQUIPMENT DATA. ALL CHANGES, ADDITIONS, OR REPLACEMENTS OF MECHANICAL - HARD HATS, EYE AND FOOT PROTECTION SHALL BE WORN ON SITE AT ALL TIMES. NO BEING REUSED MUST BE FULLY REMOVED DURING DEMOLITION. REMOVALS SHALL �y I 0"Ai 1, s.1�� 4 s�' 'rY 111¢4 3�s /rf,. x BY THE TENANT OR HIS CONTRACTOR ARE REMOVED FROM THE PREMISES AND THE MALL EQUIPMENT SHALL BE APPROVED BY THE LANDLORD PRIOR TO INSTALLATION.SUCH METAL HATS OR BUMP CAPS PERMITTED. INCLUDE, BUT NOT BE LIMITED TO: PIPING, CONDUIT, METAL STUDS, HANGING WIRE, f , ,k, - ,", IN GENERAL. CHANGES, ADDITIONS, OR REPLACEMENTS OF MECHANICAL EQUIPMENT SHALL BE - SIGNAGE: POST SAFETY OR HAZARD SIGNAGE PER OSHA REGULATIONS BILINGUAL IF ROOFTOP EQUIPMENT, CURBS, FLOORING AND PREVIOUSLY ADANDONED �' 'r"/ '"°"" "`" � ��"`�`����"'`��""'"�`��"`�""������`° ( U. COMPLIANCE/CLOSEOUT PAPERWORK SUBJECT TO LANDLORD'S MECHANICAL CONTRACTOR'S FINAL INSPECTION AND NECESSARY). IEQUIPMENT. ALL SURFACES AFFECTED SHALL BE RESTORED TO THEIR ORGINAL UOCCITANE GENERAL CONTRACTOR SHALL DELIVER THE FOLLOWING TO LANDLORD WITHIN APPROVAL. - ELECTRIC CORDS:TOOLS AND EXTENSION CORDS SHOULD NOT BE FRAYED OR CONDITION. DO NOT ABANDON PRIOR TENANT IMPROVEMENTS IN PLACE. SPACE #H6 FORTY-FIVE (45) DAYS OF COMPLETION OF TENANT'S WORK OR TENANT'S OPENING FOR 6. ALL APPLICATION OF ROOF MATERIALS FOR EQUIPMENT MOUNTING PLATFORMS, DAMAGED AND SHOULD BE EQUIPPED WITH GROUND. USE NO TOOLS WITHOUT SCHEDULE AND COORDINATE WITH MALL REPRESENTATIVE AND/OR TENANT(S) AS BUSINESS, WHICHEVER FIRST OCCURS: CURBS AND PIPE PENETRATIONS WILL BE PERFORMED BY LANDLORD'S ROOFING GROUND FAULT CIRCUIT INDICATOR (GFCI). APPROPRIATE. LOCATION: 1. NOTICE OF COMPLETION- FOR STATES WHICH PROVIDE FOR THE FILING OF SUCH IN CONTRACTOR, AT TENANT'S EXPENSE, AS PER LOCAL CODE AND LANDLORD - HOUSEKEEPING: DEPOSIT ALL TRASH AND DEBRIS IN DUMPSTER DAILY. WORK,STORAGE C. SUPERVISION CONNECTION WITH THE MECHANIC'S LIEN STATUTES, GENERAL CONTRACTOR SHALL REQUIREMENTS.THE FOLLOWING CRITERIA FOR ROOF RELATED WORK APPLIES: AND BREAK AREAS TO BE BROOM CLEANED DAILY. TENANT'S CONTRACTOR SHALL PROVIDE A FULL TIME SUPERVISOR OR REPRESENTATIVE OBTAIN, RECORD IN THE COUNTY RECORDER'S OFFICE, AND POST ON THE PREMISES - ALL EQUIPMENT PLATFORMS, CURBS, SINGLE AND MULTIPLE PIPE PENETRATIONS WILL - WORK CLOTHING: MINIMUM SLEEVE LENGTH AT FOUR (4.0) INCHES OVER SHOULDERS. ON SITE AT ALL TIMES (FOR ANSWERING QUESTIONS, MEETING WITH CITY OFFICIALS,THE E A- A RECORDED NOTICE OF COMPLETION, IF REQUIRED OR PERMITTED BY LAW, WITHIN CONFORM TO LANDLORD'S TECHNICAL CRITERIA. NO SLEEPERS ARE ALLOWED.THIS NO TANK TOP, NET SHIRTS, SHORTS, CUT-OFFS, ETC. MALL MANAGEMENT TEAM, ETC.) WHENEVER CONSTRUCTION IS BEING PERFORMED IN I %,.WP "la L" 'Mu" U"I'"A THREE (3) DAYS FOLLOWING SUBSTANTIAL COMPLETION OF TENANT'S WORK AND INCLUDES WOOD, METAL, EXPOSED AND ENCLOSED TYPES.ALL PLATFORMS, CURBS AND 6. VIOLATION OF ANY OF THESE WORK SAFETY RULES WILL RESULT IN A FINE FOR EACH TENANT'S SPACE. A FINE WILL BE IMPOSED FOR EITHER OF THE FOLLOWING FORWARD TO LANDLORD A CONFORMED COPY OF THE RECORDED NOTICE OF MULTIPLE PIPE PENETRATIONS WILL BE A MINIMUM HEIGHT OF EIGHT (8) INCHES. VIOLATION, AND WILL BE SUBJECT TO ALL PERSONAL AND/OR PROPERTY DAMAGE OCCURRENCES: EN PROVENCE COMPLETION WITHIN THREE (3) DAYS THEREAFTER. - THE INSTALLATION OF ANTENNAS OR SATELLITE DISHES IS NOT PERMITTED WITHOUT CLAIMS. 1. SUPERVISOR NOT PRESENT DURING DURATION OF CONSTRUCTION.* 2. CERTIFICATE OF OCCUPANCY-A COPY CERTIFICATE OF OCCUPANCY OR THE PRIOR WRITTEN APPROVAL FROM THE LANDLORD. M. HAZARDOUS MATERIALS 2. SITE SUPERVISOR IS CHANGED WITHOUT LANDLORD PRE-APPROVAL PRIOR TO FINAL BOUTIQUE #057 EQUIVALENT FOR THE JURISDICTION IN WHICH THE CENTER IS LOCATED, IF - ALL SINGLE AND MULTIPLE PIPE ENCLOSURE PIPING PENETRATIONS FOR ROOFTOP 1. CONTRACTOR MUST PROVIDE MSDS FORMS FOR ANY CHEMICAL OR ITEMS NOTED CHECKLIST.* WASHINGTON SQUARE MALL APPLICABLE IN CONNECTION WITH THE SCOPE OF TENANT'S WORK IN LANDLORD'S EQUIPMENT WILL BE LOCATED A MINIMUM OF FOURTEEN (14) INCHES AND A MAXIMUM BELOW FORTY-EIGHT (48) HOURS PRIOR TO USE OF THESE MATERIALS FOR D.WORK HOURS SPACE #H6 REASONABLE DISCRETION, PROOF OF PASSING ALL FINAL INSPECTIONS AND/OR OF TWENTY-FOUR (24) INCHES AWAY FROM THE EQUIPMENT IT IS SERVING. LANDLORD'S REVIEW AND APPROVAL. (CONTRACTOR SHALL ADDITIONALLY NOTIFY 1. PLEASE VERIFY AT PRECONSTRUCTION MEETING FOR THE SPECIFIC HOURS FOR THIS COPY OF ALL BUILDING PERMITS WITH SIGN-OFFS EXECUTED BY APPROPRIATE - ELECTRICAL CONDUIT WILL PENETRATE THROUGH ROOF NO FURTHER THAN MALL MANAGEMENT OFFICE 24-HOURS IN ADVANCE OF THE USE OF ANY OF THESE CENTER. 9585 SW WASHINGTON SQ. RD. GOVERNMENTAL AGENCIES. TWENTY-FOUR (24) INCHES FROM THE ROOFTOP UNIT. ITEMS), (A) TOXIC CHEMICALS; (B) EPDXIES, GLUES; (C) VINYL OR SHEET FLOORING; 2. ALL WORK WHICH MAY PRODUCE FUMES OR NOXIOUS ODORS OF ANY KIND IS TIGARD, OR 97223 3. LIEN WAIVERS-COPIES OF ALL FINAL UNCONDITIONAL LIEN RELEASES FROM ALL - ALL HVAC CONDENSATION DRAIN LINES WILL BE PIPED BACK INTO THE TENANT'S VINYL BASED MATERIALS; FLOORING, MIRROR AND ROOF MASTIC (PROVIDE MSDS REQUIRED TO BE PERFORMED AFTER THE CENTER CLOSES FOR BUSINESS.THERE ARE CONTRACTORS, SUBCONTRACTORS AND MATERIALS AND SERVICE SUPPLIERS, ON SPACE. ALL PIPING WILL BE COPPER,TYPE "M". (CHECK WITH OPERATIONS MANAGER AS AND PROOF THAT IT DOES NOT CONTAIN ASBESTOS); (D) PAINT, LACQUER, NO EXCEPTIONS! PROPER VENTILATION IS TO BE PROVIDED BY THE GENERAL AREA: 621 SF ACCOUNT OF TENANT'S WORK, SHALL BE SUBMITTED IN A LANDLORD APPROVED TO LANDLORD'S REQUIREMENT.) URETHANES, ETC., AND (E) ANY MATERIALS REQUIRING SPECIAL VENTILATION WILL BE CONTRACTOR, AND MUST BE PRE-APPROVED BY LANDLORD. FORM, NOTARIZED AND EXECUTED BY AN OFFICER OF THE COMPANY. 7. AT NO TIME MAY HEAVY EQUIPMENT BE MOVED ALONG THE ROOF. USED ONE (1) HOUR AFTER THE CLOSING OF THE MALL AND/OR COMPLETED 1 1/2 3. FOR AFTER-HOURS WORK AND ACCESS TO THE PREMISES,AN AFTER-HOURS PERMIT 4. GENERAL CONTRACTOR AFFIDAVIT-SEPARATE AFFIDAVIT FROM TENANT'S 8. LADDERS WILL NOT BE PERMITTED ON THE SIDE OF THE BUILDING FOR ROOF ACCESS. HOURS PRIOR TO MALL OPENING.THIS WILL INSURE THAT ALL ODORS WILL BE IS REQUIRED. PLEASE OBTAIN PERMIT AND COORDINATE ACCESS THROUGH THE SHEET TITLE: CONTRACTOR THAT NO LIENS EXIST AS A RESULT OF TENANT'S WORK. 9. UNDER NO CIRCUMSTANCE WILL ANY AIR OR CRANE LIFTS OF HVAC EQUIPMENT BE DISSIPATED TO A LEVEL SATISFACTORY WITH CENTER MANAGEMENT. MALL MANAGEMENT OFFICE PRIOR TO ANY WORK BEING PERFORMED. 5. AIA DOCUMENT REQUIREMENTS- ALLOWED WITHOUT PRIOR WRITTEN APPROVAL.A FORTY-EIGHT (48) HOUR NOTICE IS 2. ABSOLUTELY NO ASBESTOS-CONTAINING MATERIALS, INCLUDING BUT NOT LIMITED 4. ROUTINE INSPECTIONS WILL BE PERFORMED BY LANDLORD'S REPRESENTATIVE, REQUIRED. AIR OR CRANE CONTRACTOR MUST PROVIDE THE APPROPRIATE TO, FLOOR TILE, FLOOR MASTIC OR ROOFING MASTIC ARE ALLOWED WITHIN THE TENANT COORDINATOR, OPERATION'S MANAGER OR MALL SECURITY PERSONNEL LANDLORD NOTES INSURANCE REQUIREMENTS AS OUTLINED IN EXHIBITS B AND C OF THESE PREMISES. WHILE SOME OF THESE MATERIALS ARE STILL USED AND CAN BE WITH REGARDS TO ACCURATE PERFORMANCE OF CONTRACTOR'S WORK, SEE WASHINGTON SQUARE MALL RULES AND REGULATIONS DOCUMENT FOR MORE CONTRACTOR RULES AND REGULATIONS,AND BE IN COMPLIANCE WITH ALL PURCHASED THROUGH NORMAL DISTRIBUTION CHANNELS SUCH AS HARDWARE GENERAL SAFETY REQUIREMENTS, AND TO ENSURE ADHERENCE TO THESE INFORMATION ON CONTRACTOR RULES. APPLICABLE LAWS REGULATING SAID OPERATIONS. STORES, THEY ARE STRICTLY PROHIBITED BY THE LANDLORD. IF IT IS DISCOVERED THAT CONTRACTOR RULES AND REGULATIONS. 10. ANY UNAPPROVED WORK WILL BE SUBJECT TO CORRECTIVE ACTION BY THE THE CONTRACTOR INSTALLED ASBESTOS OR OTHER HAZARDOUS MATERIALS,THE E. WORK AREAS NOTE: LANDLORD REGULATIONS LANDLORD AT THE EXPENSE OF THE TENANT, GENERAL CONTRACTOR AND/OR CONTRACTOR WILL BE HELD RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ITS 1. TENANT'S CONTRACTOR SHALL CONTAIN ALL OPERATIONS WITHIN THE PREMISES OF SUBCONTRACTOR. REMOVAL AND DISPOSAL. THEIR SPACE AND SUCH OTHER SPACE AS LANDLORD MAY SPECIFICALLY PERMIT. GC MUST BE IN FULL COMPLIANCE WITH ALL PROJECT NO. 13-1802 11.11 ] I. ALL ROOF TOP UNITS ARE TO BE CLEARLY STENCILED WITH THE TENANT'S NAME AND N. HOT WORK COMMON AREAS, PUBLIC CORRIDORS, SERVICE CORRIDORS AND EXTERIOR OF LANDLORD CONSTRUCTION REQUIREMENTS. GC SPACE NUMBER. 1. WHENEVER ANY HOT WORKS IS PERFORMED WITHIN THE PREMISES, A FIRE WATCH LANDLORD'S BUILDING MUST BE KEPT CLEAR OF TENANT'S EQUIPMENT, IS TO CONTACT TENANT COORDINATOR SCALE: NTS 12. ANY DAMAGE TO THE ROOF INFLICTED BY TENANT'S GENERAL CONTRACTOR WILL BE IN EFFECT DURING AND UP TO ONE HOUR AFTER THE COMPLETION OF SAID MERCHANDISE, FIXTURES AND TRASH AT ALL TIMES. AND/OR ARCHITECT WITH ANY QUESTIONS AND/OR HIS SUBCONTRACTORS WILL BE CORRECTED AT THE EXPENSE OF THE WORK. A FIRE EXTINGUISHER MUST BE ON SITE.THE PROVISIONS OUTLINED IN THE HOT 2. ALL PRECAUTIONS MUST BE TAKEN TO INSURE THAT DUST AND FUMES FROM REGARDING SUCH COMPLIANCE. DATE: 04/17/13 RESPONSIBLE PARTY. WORKS POLICY SHALL BE ADHERED TO AT ALL TIMES. CONTACT THE CENTER DEMOLITION AND CONSTRUCTION REMAIN WITHIN THE BARRICADE AND SHALL NOT COORDINATE W/ MALL MANAGEMENT AS 13. ALL ROOF-RELATED IMPROVEMENTS MUST BE INSTALLED WITH FLASHING APPLIED IN MANAGEMENT OFFICE FOR SPECIAL REQUIREMENTS AND A PERMIT PRIOR TO ACCUMULATE INTO THE COMMON AREA. IF THE CENTER MANAGER OROPERATIONS REQUIRED ON TENANT CONSTRUCTION RULES DRAWN BY: KJ A MANNER ACCEPTABLE TO THE MANUFACTURER, BY A MANUFACTURER COMMENCING ANY HOT WORKS. MANAGER DEEMS DUST ACCUMULATION EXCESSIVE, IT IS THE CONTRACTOR'S APPROVED ROOFING CONTRACTOR. (CHECK WITH MALL MANAGEMENT OFFICE 2. UNDER NO CIRCUMSTANCES WHATSOEVER WILL ANY HOT WORKS BE PERMITTED RESPONSIBILITY TO PAY FOR THE CLEANUP, OR PROVIDE THE SERVICES TO CLEAN UP AND REGULATIONS. FOR REQUIRED ROOFING CONTRACTOR INFORMATION). CONTRACTOR CHARGES DURING A SPRINKLER SHUT DOWN. THE AREA, AS SOON AS REASONABLY POSSIBLE. A FINE MAY ALSO BE IMPOSED. REVIEWED BY: AD ARE AT THE TENANT'S EXPENSE. SHEET N0. TENANT CONSTRUCTION RULES & REGULATIONS EXTRACTED FROM THE TENANT HANDBOOK 2 LANDLORD REQUIRED SUBCONTRACTORS 1 /N __ - ------- NTS NTS 1_1­­___________­___­____ ­________________� ­___ - __ _________ __ - __ � - -I—-__­­­- I - � . _ _ 1 � - - - y. �s < s,t.`w / h .n' �. "F ,. y F==r,,.. ,., >, s s« r ri �. "n �.� n Eaffim s /a / .s rs ti s it'Y'> - % hfY ref 1'rz9.c z /�z h i: fi k/rf k3I .,'s �£, , I-XI ,r',•�,`' $ iY ✓/d 5/y I /� r>; ,ff/.<f -: i2� ic y'1's,/p�mo$"y� �. NOTE: CONCRETE SLAB PENETRATIONSer) l ) e,, t � a[ y r 3 //fg .. «„ fk� a :✓,t o 's w y rr dr s , z.s v c rs � � x r k/�1 �f' t g f� X335' " ALL PENETRATIONS THROUGH ANY CONCRETE FLOOR ­ 10", u/ / x 1'.. :r y s's £ t x £rS =3lw�:zi f h,, /� r,rte z� :w s;�y 11 /; s,� <;, h: ,, SLABS MUST BE COORDINATED WITH CENTER s:G,n /✓5s�,/ 1f .,:5 A �( �Aif'.Aye..',�.�iy 6: d j'. ,'i, SY / y G/f y, rR< 1. ,y��„ /" ,��gs�a,� 'g z/ �$ x .; MANAGEMENT. CORE DRILLING, SAW CUTTING, JACK /r`�i':`'/ '� 'h` f y" '4 c:'i'✓6. '/,i;',//'•,tf� .S/3': sH^ i G' ,,.i.l,' ,. d, '"`. JS f .5 5 rn x3F✓- ,g�-: yM h / $ '. aA,>!f',A Hyx r ,� ,(k < { � <y, ! �d,<tr.-n y x ..", HAMMERING, BUSH HAMMERING, CHIPPING, ETC., ARE n% t, 3,i':.>�`srfi>Ds t,.a<: any, '�';. ra s.✓ "'.:'y'�'<ry, s N �, s,,,; ,.sA dam" .: y ' 'y <.:' F> y �.xA; �/ s., NOT PERMITTED WITHOUT PRIOR APPROVAL. X-RAYS OF Architecture y a Urban Planning Y5 £1;, ,' y ,� THE AREA OF THE PROPOSED FLOOR OPENING MUST BE a ;, , :,� s Store Design Q' 3, y ff � ,"' kb;,„ TAKEN BEFORE CENTER MANAGEMENT APPROVAL. A 360 Lexin ton Avenue ,i�A':: Y $ <:. i< ,g c C 9 1'ya'N g�dr/%:,.erg` E Mixed-Use y! y l..v ` " yyk QUALIFIED X-RAY CONTRACTOR HIRED AT THE G.C.S ! �, . � New YorkONY10017 t f f ,%' j' 't%a Retail Development www.kennethpark.com a �. ���' �y;x I ' EXPENSE SHALL PERFORM ALL X-RAYS. ry/`/` '' / CENTER MANAGEMENT OFFICE APPROVAL SHALL NOT �' y s? r F' ;! t..;,.,,. ' RELIEVE CONTRACTOR FROM RESPONSIBILITY FOR YNr' /G ;i 1111�4 ' r 'j : _;' DAMAGE TO MACERICH PROPERTY AND/OR TENANTS r MEP Consultant _ PROPERTY DUE TO PENETRATION OR SAW CUTTING OF " ate. , .<,:.<, ,-.', ., ,>, ?',::: ,, ..::,,a .�.. ... y,a...€,✓:j :xaA�.4." 'aF.y,j t}j :; £ ::, ¢r a ,�rxE. �`s y5. 2'v ZI: f'sl.r�*P10 :c,i aa,"� '< t fsr., :' -. . .'. Y, ':_:.' '; .'. k.::2' l..._,.., > -.'r ..:.° f, s„ W: THE FLOOR SLAB. CONTRACTOR SHALL COORDINATE R " WITH THE CENTER MANAGEMENT OFFICE WHEN ANY 7 Y `I «. ,' r,.dA'_,s_. ,a_.,.,.<: ,✓N,.s.d�,.:;,,, �u,.«2;,r.;<,,.�,9,....r<'s�✓<..� "...,t'2�a;,: �111- >� L 1 / i yp: � 'a 'a s CORE BORING OR SAW CUTTING OF THE FLOOR SLAB IS a ,11 y' ( ) (: )B A ATTEMPTED AND PROVIDE A WATCHMAN IN H SPECIFIC AREA BELOW THE TENANT SPACE, WHERE CORE x y:,. ry P,, , m %. . < v ;F <j... n consulting engineer G, WILL OCCUR R THE DURATION OF SUCH BORING O C O S C don pen CO •n en In 5'c a, a dzz r:,.Fr / °; 'as ;?/ s ; , / Fll �Ny WORK. 635 Westport Parkway .-,y'r/ Hr > :h- /a ,&.:': S.n i; ,,y/,'<fi r 5 r 9/,i,G 2�; .o a f Suite 300 ., ,s ALL PENETRATIONS N ARE BE PROPERLY SEALED WITH P E N E A O S A O O S 'WY!.�„` /. x <k3 F.,.> �,.<:.; '•'F"' ''<..a ,. -T'c:ri'.g ,�./ ! X i, r5? / .. >•;. v, 7,r , y i':i £ f r. �{ x;. k er r« r$r v ... ... ". T. .... A , .. , ,,'. ,,,:/; fx :F;s .�,,f.: .,Y.,, ,,.r„ ..,.n.,a .., _ 4. y di,a, a .. f ..I, ,9f .b kn.. ,a,c.,<,,;; k r, r/ r.., r.v ,F.Y / , ./�./E6,f!/r.' , . ✓<Y e.. .. ,,, „l.£r ,>�. / �,.. ,. ., w y ,f ,M y. 3 K Y .,,.d> Grapevine,Texas 76051 ... <,A, r,„«,c .,,sa., ///a<, ...a:-/ti<� >. ss,.✓ ,....,,. r� f'„`..1,. ,,.,;: .: .,,, .,,, 'g.:f a., ,.yr z .'/F„sr.h,.,. a�i�f.. �,' � ': �/>. ,.;a.: ,fj,,.r.:..:. .s,:,% _,., d:,<..s s., ,,:..f 3 y,.n`y,. p s a /�:,., ,r x r ky, h t,.y„ ,,,; k EXPANDING FOAM AND FILLED WITH CONCRETE FILL OR .tip k:A:� .y ! a b s J a s y Vic, / r h,U,s:, :Y..n.,,.�Y. ,,. s;' f':, .e•3'„7£ 4, .i y rsG rs A „ ,r..,,'; _A ,, h tea: Phone:817 410 2858 !,'.f. ?',r3y�. Yv ..ipp, >l' D <; !.,A'?' » s,.'. ',r9 ��. n:�',/b r,lf, , .< .<t, AAPPLICABLEP R LD D F � s., S E BLDG CO E(S). ,l.,fs /,,,.;,,✓'y,✓ �'/r'fi< 1. i , . ) a /j/_. y ,d,/ ✓.:h`. � s ,f;/` Fax:817-251-8411 �yA . w+y 5/.xy' I'l '� >,$ f � 6 s.<�'�/ 7 >'i/. 11'11-51E 4 1 cg_' ,:,1. , 11 11 k ,�. .. ,, y" m K y 3r ,£, 1.11-1 , . EXISTING COLUMN & ENCLOSURE TO EXISTING DEMISING WALLS TO .. a .a �< ,,.,.. r.<. „: x.,. y„ ,. ,.,..,:, �.. ,� <, f<. ,.. '•h ,;. ...r, �: � .� ., . , ; REMAIN. GC TO PREPARE SURFACE TO REMAIN.GC TO PROVIDE GWB , :> . ✓ I HEREBY CERTIFY THAT THIS DRAWING H .., ACCEPT NEW FINISHES VERIFY EXACT (TYP). PATCH & REPAIR AS `_ r= NOTE. SPRINKLER SYSTEM& FIRE ALARM WORK WAS PREPARED BY ME OR UNDER MY s. i" LOCATION & NOTIFY L OCC PM & REQUIRED & PREPARE TO k t.1 "3 M Y ,-� : AGC TO MAINTAIN A VIABLE AUTOMATIC SPRINKLER w :, xs f ARCHITECT IMMEDIATELY OF ANY ACCEPT NEW FINISHES (TYP). DIRECT SUPERVISION AND THAT I AM A n :f SYSTEM DURING CONSTRUCTION. GC TO COORDINATE DISCREPANCIES. DULY REGISTERED LICENSED ARCHITECT r h: F w DESIGN, PLAN CHECK AND MODIFICATION OF EXISTING UNDER THE LAWS OF THE STATE OF Cr"�*' a # ' < FIRE SPRINKLER SYSTEM WITH LANDLORD'S DESIGNATED OREGON <: h ' � � �h FIRE SPRINKLER CONTRACTOR. 11 & 1. tt >�' tY ;fir ALL OF TENANT'S FIRE ALARM&FIRE PROTECTION ARCHITECTURAL REG. #: 372 s , r 3F :' ­01 i°gn y 11� °- REGISTRATION EXPIRES 6/30/2013 -' �. ,� a� SYSTEM WILL BE DESIGNED AND INSTALLED BY " '' LANDLORD'S FIRE PROTECTION CONTRACTOR. :: ^ �, «. . �: ,fa TENANTS G.C. IS REQUIRED TO USE L.L.S CONTRACTORS1. .,_� M..wwk.M. � � .; : r :,. � � ;'; �:- �, �. w w ._M, �.�,���.<�..�n.�.._,�.,. ,�,:<" ....... �.�..M�..�_w,,,M.....�., .�., ._._. -._.... .._._. .w ._... _,�.��_.�_.._._..,_.-.w.__ (N} TEMPORARY BARRICADE.SEE A100 D(: ' - ' 4 < (�) AT TENANT G.C.S EXPENSE, G.C.TO COORDINATE WITH FOR DETAILS. ._ _ _ _ -� ,f . MALL OPERATIONS DIRECTOR. y.; f _ Ar - # s t t NOTE: BARRICADE GRAPHICS: ALL IMAGES AND GRAPHICS ARE INDICATIVE ONLY. _ SIGNAGE CONTRACTOR TO SUBMIT ALL SIGNAGE SHOP DRAWINGS TO ARCHITECT AND LANDLORD AS PER LLBMI T SU T AL CRITERIA PRIOR INSTALLATION. Architecture Urban Planning Store Design 360 Lexington Avenue Mixed-Use New York,NY 10017 Retail Development www.kennethpark.com SQU PROVIDE Vf E DUST BARRIER 131-611 (V.I.F.) V.I.F. , b T.O. BARRICADE 3 i MEP Consultant ? r < a „ SELF-SUPPORTING BARRICADE fo 2 STUDS HEADER a.. ____ __. , . _ __ _ __ _. _. ._ __ _ __ _.___ . ___ ___.. _ _ ._. , ___ __ GC PER LL SPECIFICATIONS , CONSTRUCTED OF 2-1/2"METAL PROVIDE VI .f, S UE DUST BARRIER . f. �. ..... .:,..,.. ............., ...... , :.. ..... .E6. �.� � � ... ....,,, ......,.... ....,....., ..:.:: „.:; • S,R.. .r. f ,.v. pw ,q< ..rS.,:h..:.: .: ,o, ... ,o„3.t .3 >, ,.a STUDS &% PLYWOOD PAINTED LEASELINE `:��A.�sszP3�-w<L' ha3�:4::1>3� 3.,� a.ty "" ' y' � � � � ��� ~`� � USING AN ENAMEL OR ACRYLIC "IZVACA 1.1. n nn consulting STOREFRONT BARRICADE.3-5/9' BASED PAINT TO MATCH RAL 1028 do e c su 3 11 -- 'MELON YELLOW W L OSS GC TO 6 35 Westport Parkway yMTL.STUDS @ 161O.0 AND A Suite 300 r � >£,,:., � COORDINATE W/LANDLORD. EXTERIOR RATED PLYWOOD. ,:,� 9 �o y Grapevine,Texas 76051 PAINT AND FINISH PER SPECS P . � Phone:817-410-2858 PROVIDE ACOUSTICAL .., , FULL COVERAGE GRAPHIC Fax:817-251-8411 �e ` �. INSULATION ?, ., � � . ,. �. SIGNAGE PROVIDED & :. ., . P ;: k : INSTALLED BY SIGN VENDOR PER ROVIDE BRACING AS REQUIRED �� :.. " , :.: N .�.� � �. > SEAL:L OCCITANE TANDARDSTYP. 2x4 PRESSURE-TREATED SOLE 4 OF ALL ELEVATIONS I HEREBY CERTIFY THAT THIS DRAWING PLATE-EXTREME CARE MUST BE .r .. f: .;t: l ;� , � .; , :. . . ,s .:,; ..��� �: , .,;. ::; � � , , „ s WAS PREPARED BY ME OR UNDER MY TAKEN TO PREVENT DAMAGE TO � �; $S ,5 � .,. �..,. a�,f< ' :b y :? ,... DOUBLE DOORS TO BE FLUSH FMALL FLOORING.GC TO PROTECT - 3..., �� F� o �,� � k � � � ,�, DIRECT SUPERVISION AND THAT I AM A WITH FA BARRICADE AND RESTORE ALL MALL SPACES. DULY REGISTERED/LICENSED ARCHITECT ;. . ': N 1 11 ,;�� .k�,..< °... .. _; <:. ....� '� 5:�_ ,. ..,:: .... ., ....a ,._ GRAPHIC IS APPLIED EVENLY E.L. of F FINISH FLOOR LINE UNDER THE LAWS OF THE STATE OF 4'-5" 6'-0" 9'-11OREGON 2' ARCHITECTURAL REG. #: 3721 5'-s' 3'-11" V.I.F. 20'-5"V.I.F. V.I.F. REGISTRATION EXPIRES : 6/30/2013 BARRICADE ELEVATION BARRICADE SECTION 4 ELEVATIONBARRI ADE 1 �� �c C , ... „ X11 = 1 1_011 Z4 = 1 1_011 f� MAY a 2 2M i t Fill I I _. 05-02-13 ISSUE FOR LANDLORD& PERMIT ,o.,,® „-,� HOLD HOLD 1 — `� ' 004-19-13 PRELIM PACKAGE ISSUE CY) o , w D DATE REVISIONS KEY PLAN: z LEASE LINE vi n t. s 3 h 41_511 1.011 91 11 ?. 00 V.LF HOLD V.I.F y, 31 PROVIDE VISQUE DUST BARRIER � a�� y x:F 'Yy 20'-5"V.I.F. s yy »± GC TO PROTECT EXISTING DOOR MUST OPEN W SELF-SUPPORTING BARRICADE BY G.C., , MALL FLOOR DURING ONLY AND MUST BE CONSTRUCTED OF 2-1/2"METAL STUDSSa �g CONSTRUCTION. HIDDEN HINGED &5/"PLYWOOD PAINTED USING AN < a t 5 NORDSTROM FRAMELESS FLAT DOOR SO ENAMEL OR ACRYLIC BASED PAINT TO GRAPHICS CAN BE MATCH RAL 1028'MELON YELLOW INSTALLED OVER TOP OF IT. GLOSS'.GC TO COORDINATE W/MALL sk�A µ ► 3 ,5 a ,m : .�,. MANAGEMENT. L'OCCITANE SPACE #H6 LOCATION: 1 NOT USED 5 BARRICADE PLAN 2 L j2d N.T.S. 411 = 7 1_011 I BOUTIQUE #057 WASHINGTON SQUARE MALL GENERAL BARRICADE NOTES SPACE #H6 1. COORDINATE ALL BARRICADES AND GRAPHICS INSTALLATION WITH MALL OPERATIONS DIRECTOR. BARRICADE INSTALLATION TO BE 9585 SW WASHINGTON SQ. RD. COORDINATED W/ MALL OPERATION OFFICE. TIGARD, OR 97223 2. THE TEMPORARY BARRICADE WILL BE PROVIDED AND INSTALLED PER SPECIFICATIONS BY G.C. U.O.N. AREA: 621 SF 3. STOREFRONT BARRICADE MUST BE CONSTRUCTED WITH ONE LAYER OF 5/"THK G.W.B. ON METAL STUDS, FINISHED AND PAINTED AS DIRECTED U.O.N. SHEET TITLE: 4. THE BARRICADE CONSTRUCTION MUST EXTEND FROM FLOOR TO UNDERSIDE OF LANDLORD'S BULKHEAD AND MAY NOT EXTEND MORE THAN 3'-0" BEYOND THE LEASE LINE U.O.N. BARRICADE DETAILS 5. EXTREME CARE MUST BE TAKEN TO PREVENT DAMAGE TO THE MALL FLOORING, BULKHEAD, AND NEUTRAL PIERS. ALL DAMAGE RESULTING DURING CONSTRUCTION WILL BE ADDRESSED BY G.C. PER LANDLORD SPECIFICATIONS. 6. G.C. TO COMPLETELY SEAL OFF FROM TOP OF TEMPORARY BARRICADE TO THE BOTTOM OF SIGN FASCIA ON THE INSIDE OF TENANT'S PROJECT NO. 13-1802 SPACE SO AS TO CREATE A DUST PROOF ENCLOSURE.THE MATERIAL USED FOR THIS SHOULD BE A MINIMUM OF 4 MIL.THK.CLEAR FLAMEPROOF OR FIRE RETARDANT, POLYETHYLENE FILM. SCALE: AS NOTED 7. THE BARRICADE SHALL HAVE A FACTORY MADE DOOR WITH LOCK SET AS PER LL GUIDE LINES, WHICH SHALL BE KEPT CLOSED. DOOR SHALL SWING INTO STORE AND BE EQUIPPED WITH A DOOR CLOSER. A COPY OF THE KEY SHALL BE LEFT AT THE MALL OFFICE. DATE: 04/17/13 8. COORDINATION OFCONSTRUCTION BARRICADE AND CONSTRUCTION TRASH DUMPSTER SHOULD BE SCHEDULED WITH ON SITE DRAWN BY: KJ f MANAGER. REVIEWED BY: AD h P k SHEET NO. NOT USED 6 BARRICADE NOTES 3 N.T.S. N.T.S. -31ine /777777 ar NOTE: NOTE: EXISTING CONDITIONS GC TO PREPARE EXISTING SLAB/SUBFLOOR TO ACCEPT GC TO FIELD VERIFY ALL DIMENSIONS AGAINST LOD. NEW FINISHES AS SCHEDULED (TYP).SEE FINISH PLAN FOR NOTIFY ARCHITECT IMMEDIATELY OF FINDINGS. Architecture ADDITIONAL INFORMATION. Urban Planning Store Design 360 Lexington Avenue Mixed-Use New York,NY10017 Retail Development www.kennethpark.com NOTE: BLOCKING FOR WALL FIXTURES GC TO PROVIDE ALL NECESSARY FIRE RETARDANT MEP Consultant BLOCKING REQUIRED FOR ALL WALL MOUNTED FIXTURES. F3ry 1 £rEgS x n REFER TO PARTITION SCHEDULE FOR ADDITIONAL INFORMATION. SEE FIXTURE DRAWINGS FOR MORE Z INFORMATION, EXACT DIMENSIONS AND FURTHER FIXTURE � ': ... DETAILS. �a, F 101 STOCK ROOM 100 SALES AREA don penn m consulting engineer 635 Westport Parkway I i Suite 300 Grapevine,Texas 76051 Phone:817-410-2858 Fax:817-251-8411 41'-8" SEAL: I HEREBY CERTIFY THAT THIS DRAWING 15-3" 4'-3" 2'-2" WAS PREPARED BY ME OR UNDER MY A V.I.F. V.I.F. DIRECT SUPERVISION AND THAT I AM A 2 DULY REGISTERED/LICENSED ARCHITECT ° 4 B 14'-5 1/4" 22'-10 1/4" A3oo UNDER THE LAWS OF THE STATE OF A202 EXISTING COLUMN & ENCLOSURE TO OREGON C REMAIN. GC TO PREPARE SURFACE TO ARCHITECTURAL REG. #: 3721 1 I 1 I ACCEPT NEW FINISHES.GC TO VERIFY . EXACT LOCATION PRIOR TO REGISTRATION EXPIRES 6/30/2013 2'-1" I CONSTRUCTION, NOTIFY ARCHITECT AND L'OCC PM OF ANY DISCREPANCIES - � q IMMEDIATELY. a- ; 0o Z 2 � 0 LO o � I co 1 = - `r Q _ 00 i ti F i.G �0 7-10 3/4 YI. �t LO =C0 _ 2 Ili p , - - - 1 40.5 `- 9 ° 2 -� 0 3 3 - I - = MALL O r I A200 I o0 0 co 2 co LO CORRIDOR 4 1 GT 0 7'-9 3/8" Z A200 A201 I I 1 _ � 2 MAY 0 2 2013 ` A .. 300 _ o' 3 � Q � I I o 0- 3 I cry A200 I � 1 10 EXISTING ELECTRICAL PANEL TO REMAIN. REFER TO u. ;o A200 MEP FOR ADDITIONAL INFORMATION. GC TO VERIFY = Z - - - - - - - --- - -- -- - �o N EXACT LOCATION OF ELECTRICAL PANELS - I I FIELD �o U - � 2 AND EQUIPMENT AND NOTIFY ARCHITECT OF ANY 00 �� 1'-0" 1 DISCREPANCY `o m '2 z � ! {= 1 a 2 _ 00 GC TO PROVIDE F.T. I I 1'- "1'-0" BLOCKING FOR INSTALL OF 1 LINE OF NEW CEILING SOFFIT ABOVE,TYP. 1 EXISTING STOREFRONT TO REMAIN;GC TO WALL-MOUNTED CABINETS. SEE RCP FOR DETAILS. REFURBISH. SEE A300 FOR DETAILS. 6'-6 1/2" 6'-1 5/8" 22'-10 1/4" 05-02-13 ISSUE FOR LANDLORD & PERMIT 04-19-13 PRELIM PACKAGE ISSUE D DATE REVISIONS KEY PLAN: y i Pc r ray 03' i�� n a r 'F F 5W Y% 4. 7h. iffy S gXs al r s d� $ 9 3tys - Or r all k Sn ` 0. for agjl 0 ) f y3q ;Y z _£' f Yi }i S f Y } y NORD ? P 4 Y fir s.n NEW WORK PLAN I � y: y 3 ri Y i�r� �' � z'f'E, ��dFm�Ft��� ' yN �+�7s'RQ�I�F r '4�Fiz , ..,;.... .i.�.,. � �....::1� ...r. ���V 5..:: H.....tib... .b...,uf...-..:.5...,.....F.:..i...,dC........H.(x4, - -_- - ------- --- L'O C C ITA N E 1/4" = 1'-0" SPACE #H6 LOCATION: 1. SEE FIXTURE PLAN AND FIXTURE DETAILS FOR FIXTURE INFORMATION. SYMBOL DESCRIPTION 18. TENANTS ARE PROHIBITED FROM ALLOWING MUSIC OR OTHER SOUNDS TO EMINATE 11. ALL OUTSIDE CORNERS AT DRYWALL PARTITIONS AND FURRINGS TO HAVE METAL FROM THEIR SPACE INTO THE MALL COMMON AREA OR TO ADJACENT TENANT CORNER BEADS-SPACKLE AND SAND SMOOTH. 2. SEE REFLECTED CEILING PLAN FOR SOFFIT AND LIGHTING INFORMATION. SPACES.TENANTS WHO GENERATE MODERATE OR HIGH SOUND LEVELS (GREATER ROOM NUMBER, SEE ROOM SCHEDULE L 0 C I THAN 40 DECIBELS) OR AS OTHERWISE REQUIRED BY LANDLORD,SHALL INSULATE 12. THE CONTRACTOR IS TO REPLACE ANY FIREPROOFING REMOVED FROM THE 3. NOTIFY ARCHITECT IMMEDIATELY OF ANY INCONSISTENCIES OR DISCREPANCIES tos HC FTG RM ROOM NAME PROVENCE THEIR DEMISING WALLS AND CEILINGS AGAINST SOUND TRANSMISSION. BUILDING STRUCTURE DURING DEMOLITION/CONSTRUCTION. WITH PLANS RELATING TO EXISTING FIELD CONDITIONS. INSTALLATION METHODS MUST BE THOROUGHLY DETAILED ON TENANT'S PLAN AND 4. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE ON THE CONSTRUCTION J 3 DETAIL NUMBER BOUTIQUE #057 ARE SUBJECT TO LANDLORD'S APPROVAL.TENANTS SHALL NOT LOCATE OR DIRECT 13. ACCESS PANELS IN WALL FOR PLUMBING, MECHANICAL OR ELECTRICAL ACCESS DOCUMENTS. DO NOT SCALE DRAWINGS. Aoos WASHINGTON SQUARE MALL SPEAKERS OR ANY NOISE GENERATING DEVICES WITHIN 15' OF ANY STOREFRONT. TO BE FLUSH FRAMELESS GYP. BD. PANELS. (SEE SDETAILS ON SHEET A400) SHEET NUMBER SPACE #H6 5. DIMENSIONS ARE FROM THE FACE OF FINISHED WALL (GWB) TO FACE OF FINISHED 9585 SW WASHINGTON SQ. RD. 19. IT IS THE ARCHITECT'S RESPONSIBILITY TO INCORPORATE ALL APPLICABLE LANDLORD 14. PROVIDE DIAGONAL BRACING TO STRUCTURE ABOVE ALL DOORS, GLAZING HEADS WALL (GWB) UNLESS OTHERWISE NOTED ON PLANS. 2 ELEVATION NUMBER TIGARD, OR 97223 DESIGN AND CONSTRUCTION CRITERIA PER THE LEASE AND DESIGN MANUAL INTO AND JAMBS AS REQUIRED TO MAKE ASSEMBLY RIGID. A005 SHEET NUMBER THE PLANS.THIS CRITERIA WILL BE ENFORCED ON THE JOB WITHOUT EXCEPTION. 6. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED, AREA: 621 SF 15. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARITIONS & INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED IN 3` SECTION / DETAIL NUMBER 20. DEMISING PARTITIONS MUST BE OF FIR ECODE"X"SHEETROCK,TAPED AND SEALED STRUCTURE PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES. ACCORDANCE WITH THE MANUFACTURER'S WRITTEN SPECIFICATIONS OR INSTRUCTIONS. A005 SHEET NUMBER SHEET TITLE: AIRTIGHT TO DECK ABOVE. 16. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE FINAL CLEANUP OF THE 7, ALL WORK SHALL BE EXECUTED IN A MANNER ACCEPTABLE TO THE OWNER. 21. TENANT STOREFRONT MUST BE SELF-SUPPORTED.STOREFRONT CANNOT BE ENTIRE PREMISES INCLUDING BUT NOT LIMITED TO FLOORS, MILLWORK, FIXTURES, ETC. 2A PARTITION TYPE, SEE DETAILS,SHEET A004 NEW WORK PLAN SUSPENDED FROM MALL SOFFIT. FOLLOWING THE INSTALLATION OF THE MILLWORK. 8. ALL WOOD MEMBERS ARE REQUIRED BY CODE TO BE FIRE-RETARDANT TREATED, PROVIDE PRESSURE IMPREGNATION WITH FIRE RETARDANT CHEMICALS TO PROVIDE 22. SUSPENSION OF ANY LOAD FROM THE BAR JOISTS WILL REQUIRE LANDLORD'S FIELD 17. G.C.SHALL SUPPLY & INSTALL PROPER AND ADEQUATE WOOD BLOCKING TO UL PRS FIRE HAZARD CLASSIFICATION. ALL SUCH WOOD SHALL BE IDENTIFIED WITH A O NEW DOOR (SEE DOOR SCHEDULE,SHEET APPROVAL. NOTHING MAY BE ATTACHED TO THE OVERHEAD METAL DECKING. SUPPORT ALL OWNER SUPPLIED AND MWC APPLIED & INSTALLED ITEMS FOR FIRM UL LABEL CERTIFYING THIS CLASSIFICATION AND FM DIAMOND. X `,, �_____:_: A003) T 1 - PROJEC N0. 3 1802 AND SECURE INSTALLATION ON WALLS, COLUMNS, ETC. GC SHALL COORDINATE 9. APPROVED FIRE EXTINGUISHERS SHALL BE INSTALLED AS REQUIRED BY LOCAL 23. ALL FLOOR PENETRATIONS MUST BE SLEEVED AND SEALED LIQUID TIGHT. WITH MWC FOR REQUIRED LOCATIONS AND ADEQUACY OF BLOCKING AUTHORITY. EXISTING DEMISING PARTITIONS TO REMAIN SCALE: 1/4" = 1'-0" REQUIREMENTS AND PROVIDE ALL SUCH BLOCKING PRIOR TO CLOSING UP ANY (FIELD VERIFY EXACT LOCATION) 24. PROVIDE FLOOR DRAIN WITH CLEANOUT AND EXHAUST FAN IN TOILET&SINK AREAS. AND ALL WALLS, COLUMNS, ETC. IF REQUIRED BY CODE AND LOCAL BUILDING 10. ALL PENETRATIONS OF FIRE RESISTIVE FLOOR OR SHAFT WALLS SHALL BE PROTECTED DATE: 04/17/13 OFFICIAL, SUCH BLOCKING SHALL BE FIRE RETARDANT TREATED TO MEET SUCH BY MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO UL STANDARDS FOR NEW PARTITION 25. ONLY FIRE RETARDANT WOOD IS PERMITTED.THIS INCLUDES BACKING. REQUIREMENT. THROUGH PENETRACTION FIRESTOP SYSTEMS. THE CONTRACTOR SHALL SUBMIT (SEE PARTITION TYPES) DRAWN BY: KJ SHOP DRAWING DETAILS WHICH SHOW COMPLETE CONFORMANCE TO THE UL LISTING TO THE ARCHITECT. SUCH DRAWINGS SHALL BE AVAILABLE TO ANY CITY REVIEWED BY: AD INSPECTOR. THE DRAWINGS SHALL BE SPECIFIC FOR EACH PENETRACTION WITH ALL VARIABLES DEFINED. SHEET N0. NOT USED 4 CONSTRUCTIONNOTES 3 SYMBOL LEGEND 2 NTS NTS I 7", , - _7i777 7,7 -wen n eth KEY: 100 SALES AREA 101-0" GWB-P6 CEILING MATERIAL Architecture CEILING HEIGHT Urban Planning Store Design 360 Lexington Avenue Mixed Use New York,NY10017 Retail Development www.kennethpark.com MEP Consultant j s�' a; ; eie > 9 u tr NOTE: SUSPENDED CEILING 101 STOCK ROOM 100 SALES AREA don penn consulting engineer eerALL CEILINGS SHALL BE SUSPENDED FROM PURLINS,TOP CHORD OF BAR JOISTS, BEAMS AND/OR FLOOR 121-011 ACT 11 -0 GWB-P6 I Suite 300 estport Parkway DECKING. NO ATTACHMENT TO ROOF DECKING WILL BE Grapevine,Texas 76051 PERMITTED. Phone:817-410-2858 Fax:817-251-8411 41'-8" SEAL: NOTE: NIGHT LIGHTS & EMERGENCY LIGHTS I HEREBY CERTIFY THAT THIS DRAWING PROVIDE SEPARATE CIRCUITS FOR NIGHT LIGHTS AND 15'-3" I 1 I 4'-3" 2'-2" WAS PREPARED BY ME OR UNDER MY 01 EMERGENCY LIGHTS. PROVIDE BACK OF HOUSE LIGHTS DIRECT SUPERVISION AND THAT I AM A ON AT LEAST 2 DIFFERENT CIRCUITS FOR A400 TYP. DULY REGISTERED/LICENSED ARCHITECT CONTROLLABILITY. NEW ACCESS PANEL UNDER THE LAWS OF THE STATE OF 5 1 1 1 1 111 , 1 , 1 . 4'-0" 2'-68" 2-64" 2'-b4" 2'-b4" '-64" 2'-6- 2-64 1'-2"1 -010 JL. 2 LOCATION TO BE OREGON COORDINATED ONSITE 3'-34 8'-0" 3'-2" 1'-6" W/ L'OCCITANE PM & ARCHITECTURAL REG. #: 372 7777777 ARCHITECT TYP . ( ) REGISTRATION E IRES . 6/30/2013 NOTE: FIXTURE MOUNTED LIGHTING SEE FIXTURE DETAILS ON SHEET A401 FOR PROPER 'J2' FIXTURE MOUNTED LIGHTING INSTALLATION. i START POINT I R A EX4 C _ 4 NL F4 FOR ACT I B B B B - A $W T8 T4 C .1 " WIN. Ili : NOTE:ACCESS PANELS ;�, � A A A A A q " , NJ RE El- G.C. IS RESPONSIBLE FOR PROVIDING ACCESS PANELS - �- - IST - ---- - -�-------- 40.5 C MI9¢ �I• w _ 'I i THROUGHOUT THE LEASED PREMISES. G.C.SHALL AT MINIMUM PROVIDE 24" X 24" FLUSH MOUNT ACCESS o A A PANELS IN THE CEILING WITHIN THE LEASED PREMISES AT00 EX4 �` I "...' -- ® - - - - o DAMPERS, HVAC EQUIPMENT AND ELSEWHERE AS •i OF A A A/ L A A A/ L r : REQUIRED BY LANDLORD OR AS REQUIRED BY CODE IN 11-Aco LO ORDER TO PROVIDE ACCESS TO EQUIPMENT. Cj EMI c� A A SAY Q 70 � I I I _ rn F4 CL EN — - - - - 1 _ TRY ; ( - 00 4 1 rA:''_'A q A ;q A A A q A i NOTE: SPEAKERS _ Ts B B T PROVIDE POWER AND WIRING TO SPEAKER RUNS TO .J7 ova STOCK ROOM.SPEAKER LAYOUT, QUANTITIES AND l M4' M1' SPECIFICATIONS AS DETERMINED BY AUDIO I 1 J2 1 J2 1 J2 112 00CONSULT NT SHALL BE CO-ORDINATE WITH OWNER AND ARCHITECT. 1 -71., 1'-71 EQ. EQ. 3-6 8 8 8 lo /777777 LINEAR DIFFUSER IN EXISTING RECESSED DOWN LINEAR DIFFUSER IN TOP OF 2 FACE OF SOFFIT (TYP). LIGHTS IN BOTTOM OF NOTE: SPRINKLER SYSTEM& FIRE ALARM WORK COVE (TYP).SEE MEP 05-02-13 ISSUE FOR LANDLORD & PERMIT TY SEE MEP DRAWINGS CORNICE TO BE REMOVED' ' A400 , GC TO MAINTAIN A VIABLE AUTOMATIC SPRINKLER DRAWINGS FOR DETAILS FOR DETAILS GC TO PATCH & REPAIR SYSTEM DURING CONSTRUCTION. GC TO COORDINATE 9'-11" GWB-P1 CORNICE TO 'LIKE NEW' 04-19-13 PRELIM PACKAGE ISSUE DESIGN, PLAN CHECK AND MODIFICATION OF EXISTING CONDITION TYP . FIRE SPRINKLER SYSTEM WITH LANDLORD'S DESIGNATED 0 DATE REVISIONS FIREE SPRINKL R CONTRACTOR. 6-0 GWB-P6 8-10 GWB- ALL OF TENANT'S FIRE ALARM & FIRE PROTECTION KEY PLAN: SYSTEM WILL BE DESIGNED AND INSTALLED BY LANDLORD'S FIRE PROTECTION CONTRACTOR. , �& €: TENANT'S G.C. IS REQUIRED TO USE LL.'S CONTRACTORS 1 y itsW AT TENANT G.C.S EXPENSE, G.C.TO COORDINATE WITH MALL OPERATIONS DIRECTOR. o , �� y tZ;>xti z�4 � . ALL SPRINKLER SHOP DRAWINGS AND PERMITS SHALL BE Wyk> =f jFyx` 151s PROVIDED BY GC.SHOP DRAWINGS WILL BE SUBMITTED ¢Kf /yy MUST BE SUBMITTED TO LL REVIEW AND APPROVAL.FOR ALL FIRE PROTECTION SYSTEMS. SHOP DRAWINGS ; , 0 I NORDSTROM rp REFLECTED CEILING PLAN 1 _ _ - - --- ----- -- --- ---- L'OCCITANE 1/4" = V-0" SPACE #H6 1. SEE POWER PLAN FOR POWER AND OUTLET LOCATIONS. 1. EMERGENCY LIGHTS TO BE INSTALLED ON SEPARATE CIRCUIT.SEE ELECTRICAL SYMBOL TYPE MANUF. MODEL # LAMP QTY. RESPONSIBILITY SYMBOL TYPE MANUF. MODEL # LAMP QTY. RESPONSIBILITY LOCATION: DRAWINGS. 2. ALL ELECTRICAL AND TELEPHONE WORK SHALL BE INSTALLED IN STRICT EMERGENCY LIGHT I ACCORDANCE WITH THE ELECTRICAL CODE, NATIONAL BOARD OF FIRE 2. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO SUBMIT PLANS FOR GENERAL 169-704-10 UNDERWRITERS, PUBLIC UTILITIES COMPANY, TELEPHONE COMPANY, AND ALL MODIFICATION OF THE FIRE SPRINKLER SYSTEM AS REQUIRED TO ACCOMMODATE -_®_ DUAL HEAD,RECESSED, ENCORE EMR-12-100-250-PT 50W MR]6 2 L'OCCITANE Oq AMBIENT/ACCENT NORDIC LIGHT MEDIUM BEAM MT 35 W, G12 33 UOCCITANE OTHER AUTHORITIES HAVING JURISDICTION. THE NEW TENANT SPACE. G.C. MUST USE L.L.SPRINKLER CONTRACTOR FOR EMI CONCEALED 3000K RECESSED LIGHT WHITE EN PROVENCE -------------_ __-- --- ------ --------- -- ----- ------------------ ---- - - -- ALTERATIONS. SUBMIT SHOP DRAWINGS TO THE LANDLORD/OWNER AND � UNIV. DUAL HEAD 3. ALL COVER PLATES AND DEVICES (TELEPHONE, DATA, ELECTRIC,SWITCH) SHALL ARCHITECT FOR REVIEW. BOUTIQUE #057 32W MR16 ISI EXC2-32-X-R-U-W INC. 2 L'OCCITANE MATCH THE WALL PAINT COLOR, SEE NOTE ON A103 FOR MORE INFO.COVER EX4 EMERGENCY UNIT A LOGO PLATES TO BE RECTANGULAR. ALL OUTLETS AND SWITCHES TO BE FACING REAR OF 3. ALL FIXTURES TO BE INSTALLED IN ACOUSTIC CEILING AREA SHALL BE LOCATED AT WASHINGTON SQUARE MALL STORE. THE CENTER OF 2'-0"X 4'-0" CEILING GRID, UNLESS OTHERWISE NOTED. ECI6RWWU,6"RED LETTERS - -- SPACE #H6 4. ALL TELEPHONE OUTLETS SHALL BE PROVIDED WITH 2(TWO) PULL STRINGS BACK TO 4. ALL FINISHING AND PAINTING REQUIREMENTS SHALL BE DIRECTED TO THE FINISHES '" EX RECESSED EXIT SIGN ENCORE ON EDGE LIT CLEAR LED INC. 1 L'OCCITANE T2W TRACK, FOR SURFACE LT2P (WHITE) 0 THE TELEPHONE EQUIPMENT. SCHEDULE, SPECIFICATIONS, AND INTERIOR ELEVATIONS. EX1 ACRYLIC,WHITE TRIM - - T4W MOUNT TO FASCIA LT4P (WHITE) 2 9585 SW WASHINGTON SQ. RD. ACT CEILING 1 HR RATED'S�6"HEAVY DUTY T-BAR SYSTEM T6W SEE DETAIL DWG CONTECH LT6P (WHITE) NA 0 UOCCITANE TIGARD, OR 97223 5. THE GENERAL CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING OF ALL 5. ALL LIGHT FIXTURES INCLUDING EXIT LIGHTS, EMERGENCY LIGHTS, ETC.,SHALL BE ARMSTRONG EXPOSED GRID (AS PER ASCE STANDARD G.C. T8W 1-A400) LT8P (WHITE) 5 CHASES IN FLOOR, WALLS AND CEILING AS REQUIRED. DO NOT CUT ORGINAL FURNISHED BY L'OCCITANE, INSTALLED BY THE CONTRACTOR.SEE ELECTRICAL 2'x 2'x 3/4" 13.5.6.2.2). SEE FINISH SCHEDULE FOR SPECS. AREA: 621 SF FLOOR SLAB DRAWINGS FOR MANUFACTURER AND MODEL NUMBER. ______ _______T__________________-._.._.____._ -_ -_____ ___-_ TRACK MNTD. LED HORNET-I5-LED-E-WT- G.C. RESPONSIBLE FOR ROUGH IN, INSTALLATION BY DMX, G.C.TO B HORNET FIXTURE @ AMERLUX CFT-120-FL-3000 LED/120/FL/3000 15W 13 L OCCITANE 6. ALL SURFACES WITH EXISTING OUTLETS TO BE REMOVED,SHALL BE PATCHED FLUSH 6. CONTRACTOR TO USE LASER FOR LEVELING OF ALL SOFFITS, CEILINGS AND ® AUDIO SPEAKER 2 DMX PERIMETER SOFFIT. WITH ADJACENT WALL SURFACES. SUSPENDED GRIDS. ELECTRICAL CONTRACTOR TO VERIFY IF SERVICE PROVIDED IS COORDINATE. SHEET TITLE: ADEQUATE. IF NOT, NOTIFY ARCHITECT IMMEDIATELY. --_-_.-------___----_._.. _-----.-_-_._ ----- - -____ -- _-- - 7. EXCEPT WHERE NOTED, ALL ELECTRICAL,TELEPHONE, AND DATA OUTLETS ARE TO BE G.C. RESPONSIBLE FOR ROUGH IN &WIRING, INSTALLATION BY SHOPPER H REFLECTED MOUNTED 15"A.F.F. 7. ALL EQUIPMENT SHALL BEAR U.L. LABELS. SHOPPER TRACK 1 SHOPPERTRACK, G.C.TO COORDINATE. TRACK 8. CENTERLINE TO CENTERLINE DIMENSIONS OF ANY OUTLET PAIR OR GROUP SHALL 8. ELECTRICAL CONTRACTOR MUST PROVIDE AN IDENTIFICATION NAMEPLATE ON _ _ NOT EXCEED 6". TENANTS MAIN ELECTRICAL SERVICE FUSIBLE DISCONNECT SWITCH IN LANDLORDS 1 TC4W TRACK HUNG FROM DISTRIBUTION PANEL. NAMEPLATE MUST BE 1/8"THICK PLASTIC, BLACK ON WHITE GFRG ACCESS PANEL TR-AP018 (18"x 18') CLG @ STOREFRONT IGUZZINI 3' (WHITE) 1 L'OCCITANE CEILING PLAN 9. ALL EXISTING OUTLETS TO REMAIN,SHALL BE REPLACED WITH MATCHING ETCHED TO LEAVE WHITE LETTERS. THE SIZE SHALL BE ONE INCH HIGH BY REQUIRED / \ (SALES AREA) WIND-LOCK ROUGH OPN'G.=24"x24" (SEE NOTE: G.C. ACCESS PANELS) TabTRACK MNTD ZOOM � SPOTLIGHT WITH COVERPLATE AND DEVICE, IF REQUIRED. LENGTH, WITH TENANT'S SPACE NUMBER ENGRAVED ON IT. PERMANENTLY AFFIX TO --------------- ------ --- ------------- -------------- - - - - ---- - - - C SPOTLIGHT FIXTURE @ IGUZZINI STRAIGHT ROD 50W 4 L'OCCITANE DISTRIBUTION PANEL. SUPPLY AIR DIFFUSER/ WINDOW TABLE _ _ _ _ 50W 12 V QR CBC 51 _ _ _ PROJECT NO. 13-1802 10. PROVIDE MINIMUM 10%SPARE CIRCUITS IN EXISTING ELECTRICAL PANEL. PROVIDER A RETURN AIR GRILLES SEE MEP G.C. S401-24/30/WH,22"7W BREAKER LOCKOUTS FOR A.C. UNITS AND SEPARATE CIRCUIT OUTLETS AT TELEPHONE 9. ALL FIRE DAMPERS MUST BE IDENTIFIED BY A STICKER INSTALLED ON CEILING BELOW. FIXTURE MOUNTED T5 LED STRIP W/3000K EQUIPMENT. DUCT FIRE DAMPER MUST BE INSTALLED WITH A BREAKAWAY CONNECTION. PLENUM (SEE MECH. DINGS.) -- LINEAR LED JESCO LIGHTING WHITE,SG-BM, COM. INCLUDED 29 L'OCCITANE SCALE: 1/4 = 1'-0" CANNOT CONTAIN ANY COMBUSTIBLES. _ _ _ GRADE 80X 11. ALL WHIPS AS INDICATED FOR DISPLAY FIXTURE LIGHTS SHALL NOT BE VISIBLE FROM _ J2 (3) WIRE JESCO LIGHTING SG-CC 12 (12;,CABLE) NA lb DATE: 04/17/13 THE STORE. ALL BOXES, CONDUITS, AND WIRING MUST BE COMPLETELY HIDDEN. 10. TAPER ANY CEILING TILE EDGE THAT IS CUT TO FIT INTO THE CEILING GRID. CONNECTING CABLE SG-CC24 (24 CABLE) 3 L'OCCITANE APPROXIMATE LOCATION OF WHIPS SHALL BE 8'-6"A.F.F.. - ---- - ------ -- - ------- --- -- - --- (3)WIRE PWRCORD/PLUG__ JESC_O__LIGHTING SGPC24-W NA______ _ __ 7 L'OCCITANE 11. IF REQUIRED, ALL LIGHT FIXTURES SHALL BE TENTED IN ACCORDANCE WITH 2/32W 4' DECOR - - DRAWN BY: KJ • 12. MECHANICAL CONTRACTOR SHALL REMOVE AND REPLACE OUT FILTER AT HVAC UNDERWRITERS' LABORATORIES #P231 G4 FLUOR WALL/CLG FIXT MERCURY LIGHTING MP682320CTASWEL8120 SYLVANIA UNIT TWO (2) DAYS AFTER TURN OVER OF SPACE TO OWNER. 3 L'OCCITANE 12. SEE SEISMIC BRACING/SUPPORT DETAILS ON FRAMING/SEISMIC DETAIL SHEET IF F4 F032/835/ECO ELB UNIV _ -__ - REVIEWED BY: AD 13. PROVIDE LOCKS ON EM LIGHTS, AC,SENSORMATIC,SHOPPER TRACK REQUIRED BY BUILDING DEPARTMENT. LINEAR LED @ eW Fuse Powercore 3000 K LED INCLUDED, G oM CEILING COVE PHILIPS 1 ft: 523-000065-13 PROVIDE MOUNT TRACK& 5 L'OCCITANE SHEET NO. WALL GRAZER 4 ft:523-000065-21 LEADER CABLE AS REQ'D 3 MEP NOTES 4 GENERAL CEILING NOTES 3CEILING PLAN SYMBOL LEGEND 2 NTS NTS NTS G.C.TO PROVIDE J BOX FOR: (2) 20A DEDICATED F QUADRUPLEX OUTLETS (TYP). ennet , G.C.TO PROVIDE J BOX & 1.5"CONDUIT FOR (8) CAT .O. m.r..........._._.._... .._._. CD C5 12 $ omo�000000®®® omom00000- o o ABLE TERMINATING AT THE TELE/DATA PATCH PANEL AT I.T. CABINET; (4) FOR EA. EPOS UNIT (TYP). 6000 000 000 000 000 Architecture NOTE: RUN RIGID CONDUIT FROM J BOXES AT WALL Urban Planning SHOPPERTRAK TO OUTLETS ATTACHED TO THE INTERIOR OF THE Store Design 9 CASHWRAP. REFER TO ENGINEERS ELECTRICAL PLANS 360 Lexington Avenue AMP Mixed-Use g ❑SM O 0000 ® 4 FOR ADDITIONAL INFO (TYP). Retail Development www.kennethk,NY100 17 park.com T1 G.C. TO PROVIDE J BOX FOR CASH DESK LIGHT O 0D FIXTURES;SEE RCP FOR SPECS. I E z° ° ° 0 3 NOTE:ALL FIXTURE MOUNTED LIGHTS TO BE ON MEP Consultant DEDICATED CIRCUITS W/SWITCH CONTROL.SWITCHESxyyt�All , TO BE LOCATED BOH @MAIN SWITCH BANK (TYP). Y 011 I.T.CABINET EQUIPMENT LEGEND ' '� . ....: 1. MODEM 101 STOCK ROOM 100 SALES AREA don penn a consulting engineer 2. ROUTER 635 Westport Parkway 3. DMX EQUIPMENT SINGLE PORT CAT 6 NETWORK j SINGLE PORT CAT 6 NETWORK Suite 300 4. AMPLIFIER FOR MUSIC SYSTEM (BY VENDOR) JACK: EMPLOYEE TIME CLOCK JACK: MENS (BEHIND MENS Grapevine,Texas 76051 5.SHOPPER TRACK EQUIP. (N) THERMOSTAT(S) TO BE LOCATED UNIT FIXTURE) Phone:817-410-2858 �--- 6. POWER OUTLET STRIP (BY VENDOR) AS REQUIRED REFER TO MEP FOR Fax:817-251-8411 SINGLE PORT CAT 6 NETWORK 7. PATCH PANEL (BY VENDOR) ADD'LINFORMATION (TYP). s 41 -8 JACK: FRAGRANCE #3 (BEHIND 8. 24 PORT SWITCH PANEL (BY VENDOR) FRAGRANCE UNIT FIXTURE) SEAL: 9. 66 BOARD PROVIDED & INSTALLED BY VENDOR (N) SWITCH BANK 15-3" � 4'_3" 2'_23 I HEREBY CERTIFY THAT THIS DRAWING L. SINGLE PORT CAT 6 WAS PREPARED BY ME OR UNDER MY 4 PORT NETWORK JACK UNDER NETWORK JACK DIRECT SUPERVISION AND THAT I AM A MANAGER'S DESK, INSTALL HOUSE ABOVE CLNG DULY REGISTERED/LICENSED ARCHITECT WIRING RUN FROM MANAGER'S UNDER THE LAWS OF THE STATE OF CEILING MOUNTED OREGON DETAIL I .T. C `�/�t DESK TO I.T.CABINET (TYP). DUPLEX OUTLET ARCHITECTURAL REG. #: 3721 j 8, 5, 0„ I 3- Vit, DISPLAY TABLE POLE REGISTRATION EXPIRES : 6/30/2013 1-1/2 "=1'-0" AND MOUNTING PLATE IfNEW WALL MOUNTED I.T. - - - - = °o CABINET BY G.C.TO lg22 2 ACCOMMODATE AUDIO, N -4 DETAIL @ DISPLAY WINDOW t� TRAFFIC COUNTER & LOW VOLTAGE/DATA/TELECOM -104 54 l 1_0„ 48484848'60"60' j j ? SYSTEMS (TYP).SEE DETAIL o T --- - ___ --- - - - ---- - NOTE: ELECTRICAL OUTLET & WA 4/A 103. 84 S ALL PLATES COLOR REF. 74 ALL NEW ELECTRICAL OUTLETS AND WALL PLATES IN - J --� - - - ------ -_-- 40.5 - , 1 -� S i SALES AREA SHALL BE LUTRON 'DEC ORA'STYLE W/ DESIGNER COLOR WALL PLATES, 22"83'22' 1 J � _ _ SINGLE PORT CAT 6 NETWORK � .�^^ -AT TYP. P-1 SALES AREA WALLS- (CUSTOM COLOR- __ _ SINGLE PORT CAT 6 NETWORKj j o0 o JACK ABOVE CLNG P-4) ()V JACK:SKINCARE#2 (BEHIND o, 4'-3" / ( J �� -AT WT-1 SALES AREA TILED WALLS- BR (BROWN, SKINCARE UNIT FIXTURE) I r ARCHITECTURAL MATTE, FIN.) c� 1 -AT TYP. P-6 GWB CEILING-SW SNOW SATIN FIN. w SINGLE PORT CAT 6 NETWORK CLG.MOUNTED DUPLEX �� �+ + 3 -( ) I JACK ABOVE CLNG: FOR - RECEPTACLE. ALL NEW ELECTRICAL OUTLETS AND WALL PLATES IN BOH WI I - RELESS ACCESS POINT AREA SHALL BE WHITE. - 'O J BOX FOR SUSPENDED GC MUST CONFIRM COLOR SPECS WITH ARCHITECT ) TRACK LIGHT FIXTURE, (TYP). PRIOR TO ORDERING COVER PLATES. I 63_23, -- --- - -- - - - j 31_81, 3 - I (E) ELECTRICAL PANELS TO - - -- �IN /777777777 REMAIN, SEE MEP FOR MORE NOTE: EXISTING POWER FOR , �, INFO. 3 22 22 83 18" 22", _ , NOTE: T ,� 3, (� . CUSTOM COLOR OUTLETS P-4 O - GC TO REFURBISH TO LIKEIN ROLL UP GRILLE TO REM P-4 CUSTOM OUTLETS PROVIDED BY L'OCCITANE, - � - -� `-" NEW CONDITION. INSTALLED BY GC. TOTAL P-4 COUNT: 11 REF. 4'-3" EQ. EQ. M/WAVE j /77777777 SINGLE PORT CAT 6 NETWORK 05-02-13 ISSUE FOR LANDLORD & PERMIT NOTE: JACK:SKINCARE#1(BEHIND G.C.TO VERIFY LOSS PREVENTION SYSTEM SKINCARE UNIT FIXTURE) ' REQUIREMENTS W/ P.M. GC TO COORDINATE 04-19-13 PRELIM PACKAGE ISSUE ONSITE AS NECESSARY. G.C.TO PROVIDE (2) DUPLEXES (22"&83" G.C.TO PROVIDE (1) DUPLEX (83"AFF) FOR GC TO PROVIDE'J' BOX FOR NEW AFF) FOR EVERY GROUP OF SKINCARE EVERY GROUP OF FRAGRANCE WALL UNIT STOREFRONT SIGNAGE. GC TO COORDINATE DATE REVISIONS WALL UNIT LIGHT FIXTURES;SEE RCP FOR LIGHT FIXTURES;SEE RCP FOR SPECS. CONDUIT RUNS WITH SIGN VENDOR. NOTE: LOW VOLTAGE/DATA/TELECOM SYSTEM SPECS. NOTE:ALL FIXTURE MOUNTED NOTE:ALL FIXTURE MOUNTED LIGHTS TO BE KEY PLAN: G.C.TO RUN LINES FROM THE SPECIFIED LIGHTS TO BE ON DEDICATED CIRCUITS W/ ON DEDICATED CIRCUITS W/SWITCH NOTE: ALL SIGNAGE AND DISPLAY WINDOW LIGHTING SWITCH CONTROL. SWITCHES TO BE SINGLE PORT CAT 6 NETWORK CONTROL.SWITCHES TO BE LOCATED BOH NETWORK JACK LOCATIONS TO THE I.T. ~� � Cr��r=ry JACK: FRAGRANCE #1(BEHIND SHALL BE ILLUMINATED DURING MALL HOURS AND x f r a yjF £f n w u CABINET TELE/DATA PATCH PANEL IN THE LOCATED BOH @MAIN SWITCH BANK (TYP). @ MAIN SWITCH BANK (TYP). CONTROLLED BY A SEPARATE 7 DAY/24 HOUR TIME CLOCK. FRAGRANCE UNIT FIXTURE ) �� y. s ,✓a x � � ,�'r .as/; tx5��s'�� z f,r/Nn& a'§ -Olifl STOCK ROOM (TYP). TERMINATION PROVIDEDREFER TO STOREFRONT & ELECTRICAL DWGS FOR FURTHER y q 9 h N CEILING MOUNTED REMOTE y a a 3FrSFfY3 , 'rNrf A j BY L OCCITANE VENDOR. REFER TO TEMPERATURE SENSOR(S) TO BE SINGLE PORT CAT 6 NETWORK DETAILS. GC TO VERIFY WITH L OCCITANE PM & MALL ��c� £ s >/ t f yx / 5/ h y � 5s xs�y, xw$ xxY�cx3 ELECTRICAL DWGS FOR ADD'L DETAILS JACK: FRAGRANCE#2 BEHIND OPERATIONS IF STOREFRONT SIGNAGE &WINDOW DISPLAY Y fxt LOCATED AS REQUIRED REFER TO ( l ,. G MEP FOR ADD'L INFORMATION (TYP). FRAGRANCE UNIT FIXTURE) LIGHTING IS TO BE WIRED TO NEW DEDICATED ? xis W: CIRCUIT/TIMER OR IF TO BE CONNECTED TO LANDLORD Cir {.J Y'. 3�i%•.. »r..4 M yh`x .e..s,. , CIRCUIT TIMER REQUIRED Q CIRCUIT/TIMER. t y �I(.}R `TR{}I�'1 POWER PLAN NOTES 5 POWER PLAN Ix � i'tSTd1� 3_ z - --------- -- - --- - - - - - - ---------- - UOCCITANE 1/4 If = 1'-0" SPACE #H6 11. ALL TELEPHONE OUTLETS SHALL BE PROVIDED WITH 2 (TWO) PULL STRINGS BACK TO 1. ALL OUTLETS SHALL BE INSTALLED AS DIMENSIONED ON THIS PLAN. ANY SYMBOL MANUF. REMARKS SYMBOL MANUF. REMARKS LOCATION: THE TELEPHONE EQUIPMENT. DISCREPANCIES AS TO LOCATION BETWEEN PLAN AND EXISTING FIELD CONDITIONS SHALL BE CLARIFIED WITH THE ARCHITECT BEFORE COMMENCEMENT OF WORK. in 12. THE GENERAL CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING OF ALLI In GROUNDED 15 AMP DUPLEX RECEPTACLE SEE ELEC. DRAWINGS FOR WIRING I® DATA CABLES/FAX LINE RECEPTACLE SEE ELEC. DRAWINGS FOR WIRING CHASES 1N FLOOR, WALLS AND CEILING AS REQUIRED. 2. ALL ELECTRICAL AND TELEPHONE WORK SHALL BE INSTALLED IN STRICT EN PROVENCE WITH THE ELECTRICAL CODE, NATIONAL BOARD OF FIRE ---- ________ _.__-__-_ _ __ __________ _-_ _-.- ____ _ ______ _- _ _ - 13. ALL SURFACES WITH EXISTING OUTLETS TO BE REMOVED,SHALL BE PATCHED FLUSH UNDERWRITERS, PUBLIC UTILITIES COMPANY, TELEPHONE COMPANY, AND ALL LOCATED IN REST ROOM WITH ADJACENT WALL SURFACES. OTHER AUTHORITIES HAVING JURISDICTION. �GFI GROUND FAULT INDICATOR 15 AMP DUPLEX RECEPTACLE SEE ELEC. DRAWINGS FOR WIRING b DOUBLE JACK TELEPHONE RECEPTACLE SEE ELEC. DRAWINGS FOR WIRING BOUTIQUE #057 - - -- ---- ----- - - --- - ---- --- -- -- - -- ----- ------ - -- - - - ------- - -- - - ---- - - --- WASHINGTON SQUARE MALL 14. EXCEPT WHERE NOTED, ALL ELECTRICAL, TELEPHONE,AND DATA OUTLETS ARE TO BE 3. ALL NEW ELECTRICAL OR TELEPHONE OUTLETS SHALL BE RECESSED MOUNTED.THERE ISOLATED GROUND 15 AMP DUPLEX SPACE #H6 MOUNTED VERTICALLY 18"A.F.F. SHALL BE NO NEW SURFACE MOUNTED CONDUIT OR OUTLETS. =0 RECEPTACLE (ORANGE) -DEDICATED OUTLET SEE ELEC. DRAWINGS FOR WIRING I® COMBINATION VOICE/DATA OUTLET/RECEPTACLE SEE ELEC. DRAWINGS FOR WIRING 9585 SW WASHINGTON SQ. RD. 15. CENTERLINE TO CENTERLINE DIMENSIONS OF ANY OUTLET PAIR OR GROUP SHALL 4. IT IS THE INTENT OF THESE PLANS TO PROVIDE A COMPLETE OPERATING ELECTRICAL TIGARD, OR 97223 NOT EXCEED 6". SYSTEM. G.C. SHALL FURNISH AND INSTALL WIRING, EQUIPMENT, ETC. REQUIRED. ® GROUNDED 15 AMP DUPLEX MTD. IN CLG.-FLUSH MTD. SEE ELEC. DRAWINGS FOR WIRING POWER PANEL LOCATED AS PER CODE AFF SEE ELEC. DRAWINGS FOR WIRING 16. PROVIDE MINIMUM 10%SPARE CIRCUITS IN EXISTING ELECTRICAL PANEL. PROVIDE 5. ALL WIRING INSTALLED UNDER THIS CONTRACT SHALL BE TESTED FOR PROPER - --- -- - - --- - - _ - - -- --- ---- - - ----- - AREA: 621 SF BREAKER LOCKOUTS FOR A.C. UNITS AND SEPARATE CIRCUIT OUTLETS AT TELEPHONE CONNECTIONS, SHORT CIRCUITS AND GROUNDS PRIOR TO TURNING OVER THE ILL GROUNDED 15 AMP DOUBLE EQUIPMENT. WORK AS A COMPLETE UNIT. DUPLEX RECEPTACLE SEE ELEC. DRAWINGS FOR WIRINGF❑ FIRE ALARM MANUAL PULL STATION LOCATED AS PER CODE AFF SEE ELEC. DRAWINGS FOR WIRING SHEET TITLE: 17. TELEPHONE PANEL TO BE MOUNTED ON A 18"X 24" PTD. PLYWOOD SHEET MOUNTED 6. G.C. TO REFER TO ELECTRICAL DRAWINGS FOR IT/TELECOM LINE DIAGRAM. FIRE ALARM STROBE/SPEAKER SIGNAL DEVICE LOCATED AS PER CODE AT 48"A.F.F. W/AN OUTLET MOUNTED AT 60"A.F.F. ® GROUNDED 15 AMP QUAD MTD. IN CLG. - FLUSH MTD. SEE ELEC. DRAWINGS FOR WIRING FS] AFFSEE ELEC. DRAWINGS FOR WIRING POWER PLAN 7. SEE COLOR REFERENCE NOTE ON PLAN FOR OUTLET COVER PLATE SPECIFICATION 18. LL PANELS AND BRANCH CIRCUITS IN PANELS SHALL BE LABELED IN A CLEAR LEGIBLE INFORMATION. MANNER. 8. ALL EXISTING OUTLETS TO REMAIN SHALL BE REPLACED WITH 'DECORA'STYLE $ LIGHT SWITCH SEE ELEC. DRAWINGS FOR WIRING AD ALARM KEYBOARD SEE SHOP DRAWINGS FOR WIRING 17. ALL WORK MATERIALS AND EQUIPMENT TO BE GUARANTED FOR A PERIOD OF ONE COVERPLATES AND 'DECORA'TYPE DEVICE, IF REQUIRED.SEE NOTE#7 ABOVE --- -- ----- --------- - -- --- ---- --- -- -- --------- ------------------- - PROJECT NO. 13-1802 YEAR FROM DATE OF FINAL ACCEPTANCE. REGARDING COLOR. DOOR CHIME AT CEILING @ STOCKROOM&CASHWRAP FIXTURE SEE ELEC. DRAWINGS FOR WIRING (2) VOLUME CONTROL SEE ELEC. DRAWINGS FOR WIRING 9. THE G.C.SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL ELECTRICAL WIRING, _ _ __ _ _ _ SCALE: 1/4 II= 11-0'1 OUTLET INSTALLATION, AND CONNECTION OF POWER FEED OUTLET BOX AT ALL LOCATIONS. 0 PUSH BUTTON FOR STOCK ROOM DOOR SEE ELEC. DRAWINGS FOR WIRING 0 JUNCTION BOX SEE ELEC. DRAWINGS FOR WIRING DATE: 04/17/13 10. EXACT LOCATION FOR CORE DRILL POWER FEEDS SHALL BE FIELD VERIFIED PRIOR TO - SEE ELEC. DRAWINGS FOR WIRING, ARNEV PRODUCTS ----- ---_ - ----- ---- CORING. G.C.SHALL COORDINATE WITH ARCHITECT & LL PRIOR TO CORE DRILLING. RECESSED FLUSH MOUNT BOX:AP-1102-58 DRAWN BY: KJ NO TRENCHING ALLOWED GROUNDED 15 AMP DUPLEX FLOOR RECESSED-FLUSH MTD. (RECTANGULAR- DOUBLE FOR CONCRETE FLOORS) THERMOSTAT SEE MECH. DRAWINGS FOR WIRING W/AP-6304-DP COVER PLATE REVIEWED BY: AD CEILING RECESSED DATA PORT SEE ELEC. DRAWINGS FOR WIRING Q TEMPERATURE SENSOR SEE MECH. DRAWINGSSHEET FOR WIRING S T N0. POWER/SIGNAL PLAN NOTES - 3 SYMBOL LEGEND 2 NTS NTS t m <ennet , ar Architecture Urban Planning Store Design 360 Lexington Avenue Mixed-Use New York,NY10017 Retail Development www.kennethpark.com MEP Consultant �7 Y l>'<�l'Y/�5 3 ,� 3Yt $ Y .M 4 A• S 1,,G;". < L 1f>L$ s„ " �kl>.V�y Yk ;'S x �£ 4 „ x' ' a �� Y . �: sF� � � � �:4 r�� z ryz �� � 1,01gk 3 zID "RNs114 Y. >:s�; 101 STOCK ROOM 100 SALES AREA i I P-2 ACT P-1/P-4/WT-1 P-6 don penn consulting engineer VCT-1 B-3 CT-1 B-1 Suite 300 estport Parkway NOTE: RUST FINISH IRON BAR Grapevine,Texas 76051 G.C.TO CUT ALL RUST FINISH IRON BAR PROVIDED BY Phone:817-410-2858 UOCCITANE IN FIELD TO CONFORM WITH DESIGN 41'-8" Fax:817-251-8411 REQUIREMENTS. ALL ROUGH EDGES MUST BE GROUND SMOOTH. ALL SCREW HEADS MUST BE PAINTED TO MATCH THE IRON FINISH (REFER TO ELEVATIONS FOR 15'-31 4'-3" 2'-2' SEAL. I HEREBY CERTIFY THAT THIS DRAWING LOCATIONS). „ WAS PREPARED BY ME OR UNDER MY �" 14'-54 22-10 4� DIRECT SUPERVISION AND THAT I AM A VINTAGE MosAlc PROVIDED B DULY REGISTERED/LICENSED ARCHITECT L'OCC. INSTALLED BY GC. UNDER THE LAWS OF THE STATE OF I NOTE: FASTENING FIXTURES ALL FIXTURES MUST BE FASTENED TOGETHER BY GC. E.Q.A E.Q.A E.Q.A B E. B I CUSTOM COLUMN DISPLAY 70 70 70 80 85 35 35 36 5 35 SHELVES W/HANGING OREGON BASE SECTIONS-GC TO REMOVE TOP DRAWER,SCREW HAND CREAM FEATURE ARC H ITECTU RAL REG. #: 3721 FIXTURES TOGETHER THROUGH THE SIDE, AND LEVEL REGISTRATION EXPIRES : 6/30/2013 BOTTOM OF FIXTURES WITH LEVELERS. 12'k36" 12'k36" 12'k36" CTATi 00 UPPER SECTIONS-GC TO SCREW TOGETHER BEHIND TRANSLUCENT PLASTIC PANEL AT INCONSPICUOUS LOCATIONS I 5515 15 ALL FASTENINGS MUST BE HIDDEN FROM SALES AREA =C82 71 I Il caw- _........._... 31 `-' �' . .o 1 1 1 67 7 20 51 I 4 I - - 70 - 35 LO S WINDOW ao 90 C 78 ,€. _ PAP�C NOTE: BLOCKING FOR WALL FIXTURES 40.5 GC TO PROVIDE ALL NECESSARY FIRE RETARDANT - — — ' \W w i — � - - - �t url , BLOCKING REQUIRED FOR ALL WALL MOUNTED FIXTURES. - 63 GC MUST PATCH AND REPAIR AT DEMISING WALL TO b °0 MAINTAIN FIRE RATING.SEE FIXTURE DRAWINGS FOR c� 1 - - MORE INFORMATION, EXACT DIMENSIONS AND FURTHER 5 6 23 `r' `�' �/ ; 18OF ' 6 10 11 10 O A402 — - - - - FIXTURE DETAILS. 70 = 5 18 18 M i N iUj — — 18 2 �O -r - I M 2 1-58 111 -J NOTE. FIXTURES 4'-1 1" I , 57 ALL WOOD FIXTURES SHALL BE KILN-DRIED, MILL QUALITY :o I 5 6 4 4 4 — — FINISH AND ALL WOOD SHALL RECEIVE A FIRE RETARDANT COATING OR TREATMENT WHERE REQUIRED BY CODE. 73 45 0 66 -- - -- — 8 N co 74 6-6111 ,-1 6'-11„ 22'-101„ 2 4 NOTE: FIRE EXTINGUISHER 2 5.' 01 Ve GC SHALL PROVIDE 5 LB FIRE EXTINGUISHER TYPE"ABC" ALL-PURPOSE CHEMICAL IN ACCORDANCE TO LATEST VINTAGE WORKBENCH 2PC ADDITION OF NFPA 10 FOR SPRINKLER BUILDING. 36 65 35 37 35 35 PROVIDED BY L'OCCITANE, 35 36 INSPECTED AND TAGGED ANNUALLY BY A LICENSING INSTALLED BY GC. AGENCY. 05-02-13 ISSUE FOR LANDLORD & PERMIT 04-19-13 PRELIM PACKAGE ISSUE NOTE: CLEANING DATE REVISIONS GENERAL CONTRACTOR TO CLEAN STORE AT TURN OVER AND PRIOR TO OPENING OF SPACE. KEY PLAN: � '��•, �' .". !,.S`2 s r �✓ )Fi s t s$'3 gj $ n f Y $;y �sf !/y y ,1 Z 4r Y 3 ` S 8 4 7 ri 4„y a5 NOTE: FIXTURE DELIVERY RNA GC TO ACCEPT FIXTURE DELIVERY AT SITE & CONFIRM ; 'y'°zr �> 4` ys SGS ' 'y , �s FIXTURE COUNT AGAINST PLAN. Fy ` x x f NOTIFY CONSTRUCTION PM OF j. yx O Y DISCREPANCIES. x r ,xh ot €. U €,z< .Y�,.,v<. wya>i�,€n9e" &z s�,s•,Y �`'' "��,:Sz ,ry r k Y e ,10, t , Iiff IN NUh13`TROM FIXTURE PLAN 1 1 F3£Gy $ y1p(7( �rCk�• y' � /b•�+d''Z�.% k �,b,P::.,Y >. �` s -«T 1F___3F - --- - -- L'OCCITANE THIS DRAWING IS TO BE READ IN CONJUNCTION W/ A105 (FIXTURE SCHEDULE) 1/4„ „= 1 -0 SPACE #H6 LOCATION: 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT 1. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT AS TO ANY DISCREPANCIES IMMEDIATELY. THE JOB SITE AND NOTIFY THE ARCHITECT AS TO ANY DISCREPANCIES IMMEDIATELY. 10 AN 13. NO FIELD FINISHING OTHER THAN MINOR TOUCH-UPS OF MILLWORK WILL BE 2. GENERAL CONTRACTOR IS TO PROVIDE ALL NECESSARY FIRE RETARDANT BLOCKING PERMITTED. REQUIRED FOR ALL WALL MOUNTED FIXTURES. GC MUST PATCH AND REPAIR AT �7 DEMISING WALL TO MAINTAIN FIRE RATING. ENEN PR®�rV PROVENCE 14. MILLWORK IS TO BE FURNISHED UNDER SEPARATE CONTRACT BY TENANT U.O.N. GENERAL CONTRACTOR IS TO COORDINATE SCHEDULING WITH MILLWORKER, 3. ALL WOODWORK ATTACHED TO THE PREMISES, BLOCKING, GROUNDS ETC.,SHALL BOUTIQUE #057 ACCEPT FIXTURE DELIVERY AT SITE & CONFIRM FIXTURE COUNT AGAINST PLAN. BE FIRE RETARDANT AND COMPLY WITH THE LANDLORD'S REQUIREMENTS AND WASHINGTON SQUARE MALL 15. GENERAL CONTRACTOR IS TO PROVIDE ALL NECESSARY FIRE RETARDANT BLOCKING GOVERNING BUILDING CODE REQUIREMENTS. SPACE #H6 REQUIRED FOR ALL WALL MOUNTED FIXTURES. GC MUST PATCH AND REPAIR AT 4. ALL MILLWORK IS TO CONFORM TO A.W.I. PREMIUM STANDARDS. 9585 SW WASHINGTON SQ. RD. DEMISING WALL TO MAINTAIN FIRE RATING. TIGARD, OR 97223 5. ALL WOOD FIXTURES SHALL BE KILN-DRIED, MILL QUALITY FINISH AND ALL WOOD 16. GENERAL CONTRACTOR IS TO INSTALL ALL FIXTURES U.O.N. SHALL RECEIVE A FIRE RETARDANT COATING OR TREATMENT AS REQUIRED BY CODE. AREA: 621 SF 17. GENERAL CONTRACTOR TO CLEAN STORE AT TURNOVER AND PRIOR TO OPENING 6. ALL CABINET AND DRAWER INTERIORS TO BE CLEAR MAPLE LACQUERED PLYWOOD OF SPACE. VENEER UNLESS OTHERWISE NOTED. SHEET TITLE: 7. ALL FINISHED VENEERED WOOD SHALL BE FREE FROM KNOTS,SHAKES AND OTHER DEFECTS AFFECTING EITHER DURABILITY OR APPEARANCE, &SHALL BE CAREFULLY I XT U R PLAN SELECTED FOR GRAIN &COLOR FOR MARKED VARIATIONS AT JOINTS BETWEEN VENEERS. 8. MILLWORK CONTRACTOR TO COORDINATE WITH OTHER TRADES AND PROVIDE CONCEALED GROUNDS AS REQUIRED. PROVIDE CUTOUTS IN FIELD FOR OUTLETS PROJECT NO. 13-1802 AND EQUIPMENT AS REQUIRED. VERIFY ALL DIMENSIONS PRIOR TO FABRICATION. 9. ALL MILLWORK HARDWARE TO BE FURNISHED & INSTALLED BY MILLWORK SCALE: 1/4 It = 1'-0" CONTRACTOR U.O.N. DATE: 04/17/13 10. MILLWORK CONTRACTOR TO FURNISH & INSTALL RUBBER BUMPERS ON ALL DOORS AND DRAWERS. DRAWN BY: KJ 11. MILLWORK CONTRACTOR IS TO FURNISH FIXTURE SHOP DRAWINGS TO THE REVIEWED BY: ,gyp ARCHITECT & PROJECT MANAGER FOR APPROVAL PRIOR TO FABRICATION. SEE GENERAL NOTES ON COVER SHEET AND AS03. SHEET NO. NOT USED 3 FIXTURE PLAN GENERAL NOTES 2 NTS NTS I RESPONSIBILITY RESPONSIBILITY SYMBOL FIXTURE SKU # DESCRIPTION QTY. SYMBOL FIXTURE SKU # DESCRIPTION QTY. FURNISH INSTALL FURNISH INSTALL MANAGERS DESK 1 GC GC (D Skincare - "'Skincare"METAL LETTERS H 18cm 1 SIGNAGE SIGNAG enne aF © - IT CABINET 1 UOC UOC 20 55MOSASOL FLOOR MOSAIC LOGO (1250x800mm) 1 UOC GC REFRIGERATOR (DANBY-DAR195BL) 1 UOC GC — 73 Rte. MICROWAVE ( )EMERSON-MW8889SB 1 L'OC GC O © -- -_-- - -- --- _--- — ---- Architecture ------- — ---- — — --- ---------- -- - - --- - - -- ---------- Urban Planning 74 - LOCKERS (A+WAREHSE PR6T1 W 121812S-SU) 1 L'OC GC ® 55CSGPA2H PERFUME(FRAGRANCE) UNIT UPPER (US/CAN.) 7 MW GC Store Design O5 - BREAK DESK 1 GC GC 55CSGPA2B PERFUME(FRAGRANCE) UNIT LOWER (US/CAN.) 7 MW GC Mixed-Use Ne Lexington Avenue ---- ------------ -__------- ___- ----------- - — ------- ------ New York,NY 10017 -- --- ----- - -- 76 - O 55CSGS03H SKINCARE UNIT- DWRS.-UPPER (US/CAN.) 4 MW GC Retail Development ww.kennethpark.com 77 - NOTICE BOARD (18"x 2411) 2 GC GC 55CSGS03B SKINCARE UNIT- DWRS. -LOWER (US/CAN.) 4 MW GC ® - FILE CABINET 1 L'OC GC © 55CSGSO4H SKINCARE UNIT-GLASS-UPPER (US/CAN.) 2 MW GC MEP Consultant 79 - MANAGER'S DESK CHAIR 1 L'OC L'OC 55CSGSO4B SKINCARE UNIT-GLASS-LOWER (US/CAN.) 2 MW GC 80 - COAT HOOKS (6 HOOKS) 1 GC GC O ❑ _ 55MSM054 MEN'S UNIT 2 MW GC _.l 81 938536 ANTI-FATIGUE MAT 1 LOC GC b VGS ELECTRONIC SAFE 10"H x 14"W x 10'D 1 L'OC L'OC 90 55CSGBOIT SET OF 10 CASHIER BOXES 1 MW GC 'Am � ® - ( ) 83 - PRINTER: XEROX WORKCENTRE 3220 1 L'OC UOC CUSTOM CASHIER -EPOS (US/CAN.) 2 MW GC -- - - - --- ---- -- o ------- — --- -- -- - _ -- -------- --- ----- ---- don penn consulting engineer 84 - DRAWING TUBE 1 GC GC 10 CUSTOM CASHIER -EPOS VISUAL-LEFT (635x760mm) 1 MDSE GC 635 Westport Parkway 85 - MOP/BROOM HOOKS MOUNTED @ X'-X"AFF 1 GC GC CUSTOM CASHIER -EPOS VISUAL-RIGHT (635x760mm) 1 MDSE GC Suite 300 -- ._------ - -- -- ------- -- -------- - -- --_ --- -------- - - — - ---- gb - HARPER NYLON HAND TRUCK (PGLYSKI9BLK) 1 L'OC L'OC 1 1 CUSTOM CASHIER -WRAPPING COUNTER (US/CAN.) 1 MW GC Grapevine,Texas 76051 Phone:817-410-2858 87 - LOUISVILLE QWIK STEP STOOL,34 INCH (L-4362-03) 1 L'OC L'OC CUSTOM CASHIER-WRAP.CNTR.VISUAL(1085x760mm) 1 MDSE GC Fax:817-251-8411 gg - 13 QUART TRASH CAN (±10"DIA.) 1 L'OC L'OC 12 SEAL: 90 - CHARTER FRAME (55x72 CM) 1L'OC GC 13 I HEREBY CERTIFY THAT THIS DRAWING _-- --- --- ------------- ----- -- --- -- - -- -- - - - --- -- - -- --- WAS PREPARED BY ME OR UNDER MY - -- - - DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED/LICENSED ARCHITECT - UNDER THE LAWS OF THE STATE OF 15 55CSGARBQ CASHIER -STORAGE UNIT 3 MW GC OREGON 16 CUSTOM CASHIER -DOORS + HANDICAP SHELF 2 (1 SHLF) MW GC ARCHITECTURAL REG. ##: 3721 17 --- - - - - -- REGISTRATION EXPIRES 6/30/2013 18 m 55CSGTABI MINI-TABLE WITH INSERTS (500x500mm) 4 MW GC 19 0o ❑ 55CSGTAB3 PERFUME(FRAGRANCE)TESTER TABLE(500x500mm) 1 MW GC ' - SMALL ANIMATION TABLE 1000x500mm --- 1 MW_ -- ---- r! t'= (�3 0 55CSGTAB4 ( ) GC 55CSTA080 WINDOW TABLE (800mm) IRON FRAME 1 MW GC � 55CSVE080 WINDOW TABLE (800mm) -GLASS 1 MW GC _7 WINDOW TABLE 800mm -PACKAGING i--a � .� 55CSEM8080 ( ) 1 MW- —GC ��� 04 o. ---- - --- --- - --- - --- - - - - - -- ---- - - ---- MAY ?n 1 @7 55CSG9002 POSTER HOLDER (SET OF 2 BARS- 1 p/window) I MW GC 30i -- -- - - - - -- --- — ----- 05-02-13 ISSUE FOR LANDLORD & PERMIT 31 55VITABLE WINDOW TABLE-TABLE POLES (2 p/window) 2 MW GC 04-19-13 PRELIM PACKAGE ISSUE 32 f -- - -- - - - - - - --- -- ---- ---- 33 - - DATE REVISIONS POSTERFRAMES- LARGE 816x816mm 14 MW KEY PLAN: 35 55CSG6080 ( ) GC © 55CSG6125 POSTER + MIR. FRAMES-TALL (1290x595mm) 4 MW GC 37 55CSG6MIR MIRROR FRAME 1256x556mm-MIRROR 1250x550mm 1 MW GC 38 -- ---- -- -- ----- - q y ,> ;.�LaY K k� G i�/ya�F �h; & S �a yy xy... c� 9 E heF gg (s /s iid 3 yf hx r� si$ .10 40 - - - ----- --------- ---- £ p 41 u s - ---------------- x+ G" xi,3v o s :r,. NORDSTRoM ui t i ua :f,..,?�.sz..s. t'.,f; ,s,. �r.' 43 -- -- - -- - - - ------------- ------- - --- L'O C C ITA N E - =- --_ _ — --- -------- SPACE #H6 44 ----- - - - - -- -- ----- - -- - --- -- - - ---- - - -- - - - LOCATION: 45 ❑ - STOOLS(AT HANDCREAM BAR;RESTORATION HARDWARE) 1 L'OC GC it- -- --- - - --- --- -- - --- - - -- - -- --- - 1 46 47 �-- ]EN PROVENCE 48 49 ❑ -- - - -- _ _-- -- - - -- BOUTIQUE #057 50 �---- - -- ---__------ - - - ------- ----- -- -- --- -- ----- -- WASHINGTON SQUARE MALL 51 55CSG9001 PERFUME (FRAGRANCE) TESTER 1MW GC_ SPACE #H6 ---- -- ----- -_ _, ---- -- -_ _-_ __ 9585 SW WASHINGTON SQ. RD. 53 TIGARD, OR 97223 54 �, 55CSGTAB6 FOLDING WRAPPING TABLE 1 MW GC 55WN 55CSUPSOI SILK PAPER HOLDER 1 MW GC AREA: 621 SF 56 ® 55COLBOIT GIFT BOXER HOLDER 1 MW GC ------- -- --- - SHEET TITLE: 57 O`p 55ALC05L 5L COLUMN ALEMBIC 1 MW GC FIXTURE SCHEDULE 63 55BROUET120 WHEELBARROW (1200mm) 1 MW GC PROJECT N0. 13-1802 64 � - - -- - ----- -_ =--- _ - --- - ---- - -- ---- SCALE: NTS 65 55JAR50 EARTHENWARE JARRE (500mm) 4 MW GC 66 Q 55JAR70 EARTHENWARE JARRE (700mm) 1 MW GC DATE: 04/17/13 67 0 55ESTAG70 ESTAGNON (H 700 H x dia 400mm) 1 MW GC 68 55PANIERS BASKET HOLDER 1 MW GC DRAWN BY: KJ it bq - ------ - - ---- - _ __ --- ------ -- ----- -- ------ REVIEWED BY: AD OO - STOCK SHELVING (SEE PLAN/ELEV'S FOR SIZES) 6 STOR GC SHEET NO. F RNIT RE ( FIXTURES) ACCESSORIES SCHEDULE - ALL SKU # 's AS PER L'OCCITANE 'GREENHOUSE CONCEPT 2012' ' DESIGN GUIDE U .O. N . 2 U U & THIS DRAWING IS TO BE READ IN CONJUNCTION W/A104 (FIXTURE PLAN) NTS W AN enne ,'' car KEY: 4 P1 100 SALES AREA Architecture WALL P-1 P-6 CEILING Urban Planning Store Design 360 Lexington Avenue THIN BEAD OF CAULK FLOOR CT-1 B-3 BASE Mixed-Use New York,NY10017 /2 BETWEEN BASE AND Retail Development www.kennefhpark.com STUCCO FINISH FOR CLEAN EDGE MEP Consultant +. 1:.n •xs z; £'`,,,xa_k < y. .,.;x s zs ? ' :. �����i.�rs4`^�3.��ti,'., B-1 BASE AT SALES KEY LOCATION NET AREA (SQ.FT.) Y Z Y FLOOR, FINISH P-4. WALL FINISH INITIAL REV.1 REV. 2 REV. 3 6 F r9f to k a P-1 SALES AREA 770 101 STOCK ROOM 100 SALES AREA don penn consulting engineer 635 Westport Parkway WT-1 SALES AREA 330 P-2 ACT P-1/P-4/WT-1 P-6 Suite 300 FLOOR FINISH Grapevine,Texas 76051 VCT-1 B-3 CT-1 B-1 Phone:817-410-2858 CT-1 CT-1 SALES AREA 442 Fax:817-251-8411 VCT-1 STOCK 134 41'-8" 7 SEAL: NOTE: AREAS GIVEN IN NET SQUARE FEET. GC TO VERIFY ALL AREA I HEREBY CERTIFY THAT THIS DRAWING CALCULATIONS. 15-3' I 41-31 „ 2'-2' I 2I WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY REGISTERED/LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF TYP . BASE DETAIL SALES 3 OREGON CH C ARCHITECTURAL ITE T RAL REG #: 3721 � A REGISTRATION EXPIRES : 6/30/2013 6"=V-0" -- 13 A 42”x 30"MOSAIC TILE LOGO. G.C.TO ENTRY MOSAIC TILE ENSURE THAT A FLUSH CONDITION EXISTS LOGO FRAME TO i A003 BETWEEN THE FLOOR TILE MOSAIC TILE, HAVE MITERED (51 r AND METAL ANGLE FRAME. METAL CORNERS,TYP. ANGLE TO BE INSTALLED LAST.SEE 11 @g pp ff TRANSITION DETAIL. i -- ---- - -- —- -!- -- -- -Ii — J40.5 ; r4 D • 00 0 1 - Y �, a CY) to 4B r 4A w i I A003 Alf o M3 _ LEASE LINE -- — WT- r 4 B I FACE OF _ AO03 A003 2,-6,1 41, _- _ - — FASCIA (TYP). ( ENTRANCE. I DOORS E l CL OF DOOR/ENTRY --- -- i( ---- ---.-. -._.- ------- io,TRANSITIONLJ 1 -- ---� Z ENTRANCE OPENING A106 u_. U 001 J M (f) / , t 1 , START POINT FOR TILE START POINT FOR TILE 2 2'-3" 05-02-13 ISSUE FOR LANDLORD & PERMIT 04-19-13 PRELIM PACKAGE ISSUE ®� G.C.TO LEAVE Y4"GAP BETWEEN BRASS INLAY TILES PROVIDED BY WALL AND TILE TO ALLOW FOR ANY L'OCCITANE TO BE INSERTED AT DATE REVISIONS NOTE: MOVEMENT THAT MAY OCCUR IN RANDOM INTERVALS WITHIN TYP. FLOOR PRIOR TO INSTALLING P-1 PAINTED STUCCO, THE FUTURE. FILL GAP WITH GRAY TILES. G.C.TO CONFIRM NUMBER & KEY PLAN: BRASS INLAY TILES PROVIDED BY GC TO CONSTRUCT MOCK-UP OF FINISHED COLORED CAULK (TYP). LOCATION OF BRASS TILES ON SITE WITH r L'OCCITANE T BE INSERTED AT �" L'OCCITANE l s �# OCC O �+ SURFACE FOR APPROVAL BY CONSTRUCTION L OCCITANE PM &ARCHITECT �'y f k ' y RANDOM INTERVALS WITHIN TYP. t3 s L xs x 'L'OCCITANE' f / '. � /'...: r . � z;Nf Yd k.)• It y° ry`$ I 3 V PM. MOCK-UP TO BE 10 HIGH x 3 WIDE Fx Lx x ,xk, � ry 4�s �" n✓L,�y z n.r . c A 5 3 FLOOR TILES. L OCCITANE LOGO ILLUSTRATING SURFACE FINISH & COLOR. NOTE: GC TO TAPE OVER LOGO ON TO ORIENTATION TO MATCH FLOOR ''a BRASS TILES PRIOR TO GROUTING FLOOR qy MAT. G.C.TO CONFIRM NUMBER & s�� Q h� If LOCATE WHERE DIRECTED BY CONSTRUCTION TO ENSURE NO GROUT FILLS LOGO ILES SITE �, .w .A•,.,, I WiTHAL'OCCIOTAN PSM T&AROCH TECT PM. MOCK-UP MAY REMAIN AS PART OF THE N WORK. �NsE�� .xio .4.p,s9,6� �;-;}.` z ,•$.✓✓� � t�i E FOR 6' 37 s,�' . }y >ss,v,:. f,7.a.....,: s ✓,,.:' �V(,}RDD T{(.3r'+� NO FINISH PLAN 1 MOSAIC INLAY 4 �Ms%:z�"`�f.,@:,, ra ..:... .s:�-)� ,�«�g�f�{�IE��!>•1�2. N'........,`Y.......:F.....H....a.s�F.� L'OCCITANE 3/4" = 1'-0" 1/4' = 1'-O" SPACE #H6 LOCATION: 12. THE FINISHED FLOORING IS TO BE PROTECTED BY G.C. FOLLOWING INSTALLATION. 1. ALL INTERIOR FINISHES ON WALLS IN PREMISES SHALL HAVE A MINIMUM CLASS II KEY DESCRIPTION NOTES GENERAL LOCATION RESPONSIBILITY FLAME SPREAD RATING AS REQUIRED BY CODE. 13. THE FLOORING CONTRACTOR SHALL HAVE A MINIMUM OF FIVE YEARS EXPERIENCE WALL BASE Uff .11 WORKING WITH THIS TYPE OF PRODUCT. 2. ALL ADHESIVES AND SEALANTS, INTERIOR PAINTS AND COATINGS, CARPET SYSTEMS, LO A COMPOSITE WOOD AND LAMINATE ADHESIVES, MATERIALS, FURNITURE AND B-1 CLEAR PINE- 1/2"x 4"CLEAR PINE BASE PAINTED P-4 _ G.C. T RU VIDE A P D, SALES AREA _ FURNISHED & INSTALLED BY G.C. N PROVENCE 14. THE G.C.SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL FINISHES IN THE SEATING USED IN THE BUILDING INTERIORS SHOULD NOT EXCEED THE VOC CONTENT G.C. N BASE BEHIND FIXTURES, TYP.SEE DETAIL 3/A106. B-2 STONE SOURCE- MARBLE SLAB MATERIAL BASE, 3/$'X 12" L. MIN., CREMA MARFIL, HONED FINISH STOREFRONT RUN BASE, PROVIDED &INSTALLED BY GC STOREFRONT FURNISHED & INSTALLED BY G.C. STORE. G.C.SHALL TOUCH UP ALL CORNER BEADS, WALLS, CEILINGS AND LIMITS AS SET FORTH IN THE GUIDELINES PRESCRIBED BY LEED IEQ CREDITS 4.1, 4.2, PROVIDE MITERED CORNERS & 1/8" BEVELED EDGES ---- BOUTIQUE #O57 , FLOORING AS REQUIRED, INCLUDING ANY DAMAGE CAUSED BY OTHER TRADES 4.3, 4.4 AND 4.5. B-3 ARMSTRONG -4" HIGH VINYL BASECOLOR #46'CONCH' NOT IN PUBLIC VIEW B.O.H. FURNISHED & INSTALLED BY G.C. INCLUDING MILLWORKER, PRIOR TO TURNOVER WASHINGTON SQUARE MALL 3. EXAMINE ALL SURFACES TO BE PAINTED UNDER THIS CONTRACT AND SEE THAT THE WALL FINISH SPACE #H6 15. G.C.SHALL CAULK BETWEEN MILLWORK AND GYPSUM BOARD WALLS IF REQUIRED WORK OF OTHER TRADES HAS BEEN LEFT OR INSTALLED IN A SATISFACTORY P-1 PI E- IXED STUCCO, PTD: BENJAMIN MOORE-"MUSHROOM CAP #177"LATEX PAINT-FLAT _ -_ _ SALES AREA — -- STUCCO FURNISHED BY L'OCCITANE, INSTALLED 9585 SW WASHINGTON SQ. RD. TO CREATE A SMOOTH FINISH. CONDITION TO RECEIVE PAINT OR SPECIFIED FINISH. PAINT FURNISHED&INSTALLED BY GC. P-2 BENJAMIN MOORE-"MUSHROOM CAP #177"LATEX PAINT-EGGSHELL FINISH DOOR FRAME TO BE PAINTED WITH SEMI-GLOSS FINISH ON STOCK ROOM SIDE B.O.H. FURNISHED & INSTALLED BY G.C. TIGARD, OR 97223 4. INTERIOR GYPSUM WALLBOARD SURFACES SHALL BE WIPED WITH A DAMP CLOTH - --- -- -- - -----� -- -- -- -- 16. ALL FLOORING TRANSITIONS MUST BE SMOOTH AND FLUSH. THE USE OF PLASTIC, O-EI�ISRYCA�US�TTO-F�CfiORYAPPLiEIS"BR�OCT��fvTMATTE`rDRYD���600�4 gAT ' VINYL, OR RUBBER TRANSITION STRIPS IS STRICTLY PROHIBITED. TENANTS MUST UTILIZE JUST PRIOR TO APPLICATION OF THE FIRST COAT OF PAINT IN ORDER TO LAY FLAT P-3 CAL131581H,CONTACT NO.: (909) 930-9100 MUST BE APPLIED AT FACTORY, NOT IN FIELD STOREFRONT AREA/LIGHT BOX FURNISHED & INSTALLED BY G.C. A HARD SURFACE TRANSITION. NO RUBBER OR VINYL BASE IS PERMITTED IN THE SALES ANY NAP WHICH MAY HAVE FORMED IN SANDING. AREA: 621 SF P-4 BENJAMIN MOORE-"MUSHROOM CAP #177" LATEX PAINT-SEMI-GLOSS FINISH PAINT STOCK ROOM DOOR & FRAME ON SALES AREA SIDE. SALES AREA FURNISHED & INSTALLED BY G.C. AREA OF THE PREMISES. P-5 BENJAMIN MOORE: AURA EXTERIOR - BASE 632-4x, Y3-1x0, R2-0x8, Y1-12x0 (RAL#1007): STOREFRONT FINISH PROVIDED BY G.C. STOREFRONT PANELS FURNISHED & INSTALLED BY G.C. SHEET TITLE: 5. PAINTER SHALL BE RESPONSIBLE FOR THE REMOVAL OF HARDWARE,SWITCH AND FLAT FINISH OUTLET COVERS, ETC., AND REINSTALLATION OF SAME AFTER PAINTING. P-7 SPRAY APPLIED ENAMEL PAINT 1N/ FLAT FINISH, BENJAMIN MOORE: STOREFRONT FINISH PROVIDED BY G.C. STOREFRONT AREA FURNISHED & INSTALLED BY G.C. AURA EXTERIOR-BASE 4 632-4x, R2-4x_0,S1-5x0, W l-Ox5,Y2-4x30_LRAL #8017 6. FOR PAINTING APPLICATION PROCEDURES SEE SPECIFICATIONS. WT-1 4"x 4"GLAZED CERAMIC WALL TILE, ZELLIGES BLUE/GREY SET TILES USING BOSTIK"TILE MATE" (762 GRAY) NON SANDED THIN SET MORTAR OR OTHER THIN SKIN CARE WALLS TILE FURNISHED BY L'OC,INSTALLED BY GC.GC ---- ---- --- -- - -- --- - SET MORTAR COMPLYING W/ANSI A]181. GROUT JOINTS SHALL BE 1/16" IN LATICRETE:SMOKE TO PROVIDE ADHESIVE,GROUT AND SEALER TYP). FINISH PLAN GRAY #89. G.C.TO THOROUGHLY MIX TILE AS COLOR VARIES FROM BOX TO BOX. 7. AT COMPLETION OF PAINTING, ALL PAINT MATERIALS AND EQUIPMENT SHALL BE REMOVED, ALL PAINT SPOTS REMOVED, AND ALL AREAS THOROUGHLY CLEANED. CEILING ANY DIRT OR DEBRIS CAUSED BY WORK SHALL BE CLEANED UP AS WORK PROGRESSES. P-6 BENJAMIN MOORE-"DECORATOR'S WHITE"LATEX PAINT-FLAT FINISH ALL GYP. BOARD CEILINGS _ SALES AREA &B.O.H. FURNISHED & INSTALLED BY G.C. PROJECT NO. 13-1802 _WWSTR­ON_G_A­C1­ x x 44", 1 HI�RRTED-FNE-H-SSURE RELUD-EXL-FIR �s „ ACT �6 HEAVY DUTY T-BAR SYSTEM EXPOSED GRID (AS PER ASCE STANDARD 13.5.6.2.2) STOCKROOM FURNISHED & INSTALLED BY G.C. EN WORK A DIRECTED 8. RETOUCH OR REFINISH SURFACES DAMAGED BY SUBSEQUENT s SCALE: 1/4 11= 1'-0" BY GENERAL CONTRACTOR. THE COST OF SUCH RESTORATION WORK SHALL BE FLOORING BORNE BY THE CONTRACTOR. CT-1 4"x 4"HEXAGONAL CERAMIC TILE SET TILES USING BOSTIK'TILE MATE"(GRAY-760)OR OTHER THIN SET MORTAR COMPLYING W/ANSI Al 181. SALES AREA TILE FURNISHED BY L'OCCITANE, INSTALLED BY DATE: 04/17/13 GROUT JOINTS SHALL BE 3/16 (5mm)IN LATICRETE 89 SMOKE GRAY&SEALED W1 AQUA MIX#15 GOLD SEALER, GC. GC TO PROVIDE ADHESIVE, GROUT AND 9. WIPE CLEAN ALL SURFACES WITH A DAMP CLOTH. MAT FINISH,G.C.TO TREAT ON SITE. PROVIDE 3/8"CONTINUOUS EXPANSION JOINT AGAINST DEMISING WALLS .SEALER (TYPJ AND INTERIOR PARTITIONS. CAULK EXPANSION JOINT WITH LIGHT GRAY LATEX AS NECESSARY.COORDINATE DRAWN BY: KJ 10. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROPER PROTECTION AGAINST TILING STARTING POINTS WITH LOCATION OF ENTRANCE DOORS AND COCOMAT,SEE FINISH PLAN. — ' ARMSTRONG STANDARD EXCELON IMPERIAL TEXTURE COMMERCIAL FLOORING- 8'THICK DAMAGE TO EXISTING FURNITURE, ADJACENT FINISHED WORK, FLOORING, ETC. VCT-1 ,I I, II Ii - STOCKROOM FURNISHED & INSTALLED BY G.C. 12 x12 VINYL COMPOSITE TILE, COLOR #51879 ETRUSCAN RED — _- __________ ___ __________.,_____ _ ___._ ___ _ REVIEWED BY: AD 11. REFER TO DETAIL SHEETS FOR APPLICABLE FLOOR TRANSITION DETAILS NOTE: CONTRACTOR SHALL REFER TO ARCHITECTURAL SPECIFICATIONS FOR COMPLETE FINISH SPECS AND REQUIREMENTS.ALL FINISHES TO BE APPROVED BY ARCHITECT.LARGE PAINT SAMPLES TO BE APPROVED ON SITE BY ARCHITECT.PAINT TO BE LEVEL 5 FINISH. SHEET NO. LEGENDFINISH NOTES 5 FINISH SCHED LU E 8� 2 NTS NTS J i I 4 LU W Z Z QQn n eth ar 0 0 O O , „ _ E.L.29 4 B.O.E. DECK B.O.E. DECK Architecture I ` 4 Urban Planning Store Design 360 Lexington Avenue Mixed-Use New York,NY 10017 77777 Retail Development www.kennethpark.com , MEP Consultant SILK PAPER HOLDER, f F = s PROVIDED BY L'OCCITANE, y INSTALLED BY GC. g'Y .•sSy %�' a. G.C.TO PROVIDE (2) G.C.TO PROVIDE (2) VINTAGE MOSAIC 816mm POSTER DUPLEXES 22"&83"AFF PROVIDED BY L'OCCITANE, SEE 2-A401 FOR k J y DUPLEXES (22"&83"AFF) ( ) TA B FOR EVERY ROUP OF FOR EVERY GROUP OF INSTALLED Y GC. DETAILS (TYP). SKINCARE WALL UNIT SKINCARE WALL UNIT don pens consulting engineer LIGHT FIXTURES (TYP). LIGHT FIXTURES (TYP). 635 Westport Parkway 2 22 Suite 300 A400 A400 A400 — i„ 1„ Grapevine,Texas 76051 3'-2' 2-1 12 3' 1" 4' 6" CE 4' 6" 4' 6" 4' 6" 1 -92 Fax 817-251-84118 858 EQ EQ. 12 T.O.SOFFIT 1 11 T.O.SOFFIT . ......... .. SEAL: 11 -o - ER BY ERTIFY THAT THI D AWIN i� B.O.CLG @ SALES I H E C S R G - ao B.O.CLG @ SALES - iv - - - - WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A 816cm 816cm 816 m 816cm _ 816cm - 816cm _ 816cm DULY REGISTERED/LICENSED ARCHITECT POSTER T - _ POSTER POS ER POSTER POSTER POSTER POSTER 8'-10" UNDER THE LAWS OF THE STATE OF B.O.E. ENTRY SOFFIT OREGON - EQ. ARCHITECTURAL REG. #: 3721 EQ. EQ. - - REGISTRATION EXPIRES : 6/30/2013 ° f POSTER FRAME .1.E (595xl 290mm) - G.C.G C TO PROVIDE (1) ° REFER TO DTL. ° 116-1 ❑ EX (83' AFF) FOR EVERY P1 P1 DUPLEX R 4-A401. GROUP OF FRAGRANCE UNITS LIGHT FIXTURES (TYP). POSTER FRAME = ° 595xl 290mm I"i > ° REFER TO DTL. ° lr:'! 4-A401. , I � o 0 0 o i o 0 0 0 I w: s- i O O O O L. O O I; { 0 0 :I O O O O O O I 01 Oil E.L.ol_oll - MAY p 2 2013 E.L.E. . RMA M�Iwgm 027 Mmmmm�- FINISH FLOOR LINE FINISH FLOOR LINE SKINCARE UNIT SKINCARE UNIT SKINCARE UNIT SKINCARE UNIT CASHIER CASHIER MENS MENS FRAGRANCE FRAGRANCE B1 W/STORAGE W/STORAGE W/STORAGE W/GLASS STORAGE STORAGE UNIT 011 UNIT UNIT UNIT FOREGROUND BASE TO BE CONTINUOUS BEHIND FIXTURES, (TYP) ELEVATIONRINTERIOR ELEVATION 3 INTERI® 1 I� 3/811 _ 1 1.011 3/811 _ 1 1_O 05-02-13 ISSUE FOR LANDLORD & PERMIT 04-19-13 PRELIM PACKAGE ISSUE w w _Z Z_ J A DATE REVISIONS 0 0 J J KEY PLAN: ' A Y ..... r .. j .. .:.. :.,:.. ::. .-::. ... ... 2 4 E. 7777 7 EL.29'-4" *B.O.E. DE B.O.E. DECK t .�'`.a>s' ys'xS.ssv. ,m?.. ✓F .: 3£y 1�/ r u �. �y�`y_: :CM6:, y,?x " "L y 4 r� .�'� � tr..vc/,< rhe-sar,3• : V e j"? ',.s ,w u,.. n!Nra,may s S•fiYf,d / :n,:,a' y Yj:.,y<sP B v ��i... ...�� _ ! ,.fi fir. •' fs,,�,? `r SY PIN MOUNT LETTERS ! G.C.TO PROVIDE (1) i �,,," a s„ xs hs /sal PROVIDED & INSTALLED BY l OL ALEMBIC PROVIDED BY L£� y, '�ct4rROM rr;r L'OCCITANE SIGN j DUPLEX (83 AFF) FOR EVERY L'OCCITANE, INSTALLED BY GC. GROUP OF FRAGRANCE N <_ $£ ' VENDOR;SIGN TO BE 3 j , R u F Sys/? Psi §s? ✓ w S 3/s UNITS LIGHT FIXTURES (TYP). MOUNTED W/ 1/2" MIRROR FRAME (595x1290mm) ( , UOCCITANE SPACERS FOR UNIFORM VINTAGE 2PC 'WORK BENCH' REFER TO DTL 4-A401. G.C.TO PROVIDE (2) SPACE #H6 GAP BETWEEN LETTERS & UNIT PROVIDED BY DUPLEXES (22'&83"AFF) FASCIA. L'OCCITANE, INSTALLED BY GC. FOR EVERY GROUP OF 2 SKINCARE WALL UNIT LOCATION: 1 EQ. EQ. EQ. EQ. 1 1 11 1 11A400 1 11 1 11 400 LIGHT FIXTURES (TYP). A400 A400 2-6 41-611 41-61 4-6 41-61t 2'-4" 3-1 - r — — — — — — - -- -- EQ. EQ. 12'-011 121_011 T.O.SOFFIT T.O.SOFFIT EN PROVENCE O 111_oll 11'-011 BOUTI UE #057 LL' u 00 — — --- — B.O.CLG @ SALES - B.O.CLG @SALES Q WASHINGTON SQUARE MALL #H 816cm 816cm 816cm 816cm 816cm 816cm 816cm SPACE 6 POSTER POSTER POSTER POAv- STER POSTER POSTER POSTER 9585 SW WASHINGTON SQ. RD. TI ARD, OR 972FP11 23 P1 WT 1 EQ. EQ. EQ. Q. OPEN O POSTER FRAME AREA: 621 SF SKINC E EQ. EQ. r ° (595x1290mmj EREFER TO DTL.4-A401. SHEET TITLE: P4 _ 55x72cm SALES AREA CHARTER- POSTER FRAME � � FRAME CHARTER FRAME (55X72) (595x1290mm) _..._ a 0REFER TO DTL. ° r ° ELEVATIONS m PROVIDED BY L'OCCITANE, i I INSTALLED BY GC. 4-A401. BLUE VINYL GRAPHIC ON DOOR PROVIDED & �. ,,' PROJECT NO. 13-1802 / INSTALLED BY SIGN VENDOR. ,,� { _ S 0 0 SCALE: AS NOTED O O I I ............ DATE: 04/17/13 � , I E.L.01_0„ O I - ,. ... ... , � FINISH FLOOR LINE .. ,. -� FINIS0'-U' HOFLOOR LINE .. .. :F. ; . ,: _. DRAWN BY: KJ ' B1 B1 B1 FRAGRANCE FRAGRANCE FRAGRANCE FRAGRANCE FRAGRANCE B1 SKINCARE UNIT SKINCARE UNIT TO STOCKROOM UNIT UNIT UNIT VINTAGE'WORKBENCH' UNIT UNIT W/GLASS W/STORAGE REVIEWED BY: AD SHEET NO. INTERIOR ELEVATION 4 INTERIOR ELEVATION 2 13/8 11 - 1 1_011 3/811 = 11.011 chn h k net ar E.L.29'-4" B.O.E. DECK Architecture Urban Planning Store Design 360 Lexington Avenue Mixed-Use New York,NY10017 Retail Development www.kennethpark.com LINE OF COLUMN IN MEP Consultant FOREGROUND;SEE A402 g n yY, rsF F Y �" �� � ..3�x1�"ms c•zs r i �s:. r a d 9 '� FOR DETAILS. C, CLG. MOUNTED EXIT , : s SIGN, SEE RCP FOR � y �rs� SPECS. don penn consulting engineer 635 Westport Parkway Suite 300 1 Grapevine,Texas 76051 A400 A400 Phone:817-410-2858 --- -- — — — ._._ Fax:817-251-8411 2-011 T.O.SOFFIT . SEAL: — — — — EXIT — — — — B.O.CLG @ SALES I HEREBY CERTIFY THAT THIS DRAWING I WAS PREPARED BY ME OR UNDER MY DIRECT I I SUPERVISION C SU SIONANDTHATIAMA DULY REGISTERED/LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF I OREGON ARCHITECTURAL REG. #: 3721 REGISTRATION EXPIRES : 6/30/2013 I I I I — I I ! I A I I ! I I I I ! I I I I I I a"; OPEN TO MALL I I I COMMON AREA ( F_ I JrF$ rI I I I / ! I I I / 1 I IT V OF I • 5 r—� I I MAY 1 0 2 l�y� 0)j I I E.L.0'-0" FINISH FLOOR LINE B1 B2 B1 1131 WINDOW TABLE EXISTING STOREFRONT BEYOND. NOT USED 3 INTERIOR ELEVATION 1 3/8 11 = 1'-0" 05-02-13 ISSUE FOR LANDLORD & PERMIT • 04-19-13 PRELIM PACKAGE ISSUE NOTE: BLOCKING FOR WALL FIXTURES NOTE: FASTENING FIXTURES GC TO PROVIDE ALL NECESSARY FIRE RETARDANT ALL FIXTURES MUST BE FASTENED TOGETHER BY GC. DATE REVISIONS BLOCKING REQUIRED FOR ALL WALL MOUNTED BASE SECTIONS-GC TO REMOVE TOP DRAWER,SCREW FIXTURES. GC MUST PATCH AND REPAIR AT DEMISING FIXTURES TOGETHER THROUGH THE SIDE, AND LEVEL WALL TO MAINTAIN FIRE RATING.SEE FIXTURE BOTTOM OF FIXTURES WITH LEVELERS. KEY PLAN: DRAWINGS FOR MORE INFORMATION, EXACT UPPER SECTIONS-GC SCREW TOGETHER BEHIND '':b r�✓< :,. F ry 2 3 4 ' �) Y t„S . s.� Fh Y S 3 GRAPHIC PANEL AT INCONSPICUOUS LOCATIONS. s y j3 h= Frx � DIMENSIONS AND FURTHER FIXTURE DETAILS. ALL FASTENINGS MUST BE HIDDEN FROM SALES AREA 4 r2 f Fri rr y k �, Et3• �' s y � e J , i � ,v, eta 'f �' s ' ¢ J �rNor 4�s yY Y i EM rL 1 s r ', 4 .✓ i..F ��0{R6/'11`()I�'f R ES L'OCCITANE SPACE #H6 d. LOCATION: A 1 D B A202 \ 1 EN PROVENCE A200 0 _j C BOUTIQUE #057 WASHINGTON SQUARE MALL A2oo SPACE #H6 4 9585 SW WASHINGTON SQ. RD. 2 W 3 A2oo A2oo TIGARD, OR 97223 A200 I j – -- ---- --- --- --- -- - -- - - I AREA: 621 SF SHEET TITLE: SALES AREA ELEVATIONS PROJECT NO. 13-1802 SCALE: AS NOTED DATE: 04/17/13 DRAWN BY: KJ REVIEWED BY: AD SHEET NO. NOT USED 4 KEY PLAN 2 NTS I I J W OZ LL_ _J j. __.. , _ �- _ _ 1 - _ 4 __._. __ _24 11 A F •,.., _._ _ 4 _ _2 11 A.F.F. _ . _ _ __ _ _ .F. . _,_ __. : _ __ 2 1 1 A.F.F. 24 1 A F 1 . .F. old B.O.E. DECK (V.I.F.) B.O.E. DECK (V.I.F.) B.O.E. DECK (V.I.F.) B.O.E. DECK (V.I.F.) <e n n* et ar Architecture Urban Planning n Store Desi g — — xih 360 Lexington Avenue e ue i Mixed-Use New York,NY 10017 � G.C.TO SECURE HEAD SECTION Retail Development www.kennethpark.com TO WALL USING WALL ANCHORS & BLOCKING AS REQUIRED. 12'-0"A.F.F. 12'-0"A.F.F. 12'-0"A.F.F. 12'-0"A.F.F. _ PROVIDE CROSS BRACING AS MEP Consultant B.O.ACT CLG 'I' B.O.ACT CLG B.O. ACT CLG _v REQUIRED TYP. FOR ALL UNITS B.O ACT CL ( ) .g s G F 3 , / K�7 A202 ) 5 PROVIDE (8) ADJ. TRIPP LITE 9U WALL MOUNT RACK 5 � v A202 A202 [P2] 8 SHELVES P/UNIT P2 / ENCLOSURE SERVER CABINET, i PROVIDED BY L OCCITANE L n U.O.N. (TYP). — —� WALL MOUNTED EXIT �o A202 INSTALLED BY GC � n FPj SIGN,SEE RCP FOR �.. _ — GC TO PROVIDE - PENCO"CLIPPER P2 EXIT _ BLOCKING IN WALL PROVIDE (8) ADJ. 4 NEW WALL MTD.I.T. (N) LOCKERS BY G.C. SPECS. SHELVES P UNIT N 2'_15„ HI-PERFORMANCE SHELVING" don penn Consulting engineer 1 OR Westport k AS REQUIRED F 635 We ort Par wa RAY FINISH, B STORAGE E EJ CABINET BY G.C. (— G IN Y O G p Y DRAWING TUBE / — _ _� CABINETRY. U.O.N. (TYP). i VENDOR. Suite PROVIDED P2 — ° N MOP BROOM _ Grapevine,Texas 76051 \ I ED O — N MICROWAVE BY ( ) / R IKEA NUMERAR #500.864.16, ( ) - - II _ Phone:817 410 2858 EXSTG.ELECTRICAL INSTALLED BY GC;SEE / �° G.C_ P2 HOOKS BY G.C. 73�"x 255" GC TO CUT ON SITE a 8 - Fax:817-251-8411 \ PANELS.SEE MEP. DETAILS 2/A202. / P2 (N) COAT HOOKS BY PER DETAILS \ I I SWITCH BANK / (N) NOTICE BOARD (N) BREAK DESK I / G.C. (24"X54") BY G.C. METAL BRACKET SECURED TO SEAL: / _ \ i - (N) MINI-FRIDGE o / WALL, BY G.C. � _ 4 z "' I HEREBY CERTIFY THAT THIS DRAWING / i \ _ PROVIDED BY � � \ °� 4� DO NOT INSTALL FRONT-MOST WAS PREPARED BY ME OR UNDER MY / I M \ _ L OCCITANE, BRACING FOR INSTALL OF SAFE. DIRECT SUPERVISION AND THAT I AM A \ INSTALLED BY GC E.L.o'-o" E.L.0'-0" 1j, E.L.o'-o" E.L.o'-o" / DULY REGISTERED/LICENSED ARCHITECT — — — — FINISH FLOOR LINE FINISH FLOOR.LINENk UNDER THE LAWS OF THE STATE OF TO ALL CORRI Q� 4' — — FINISH FLOOR LINE FINISH FLOOR LINE 2'-6" 2'-6 4'_6„ 3'-0" 3'-0" 3'-0" B1 B1 [B�l B1 MANAGER'S DESK TO BE FURNISHED AND INSTALLED BY G.C; OREGON MGR S DESK TO SALES SHELVING BY BREAK DESK SHELVING BY IKEA'NUMERAR'SURFACES TO BE FASTENED TO PENCO ARCHITECTURAL REG. ##: 3721 STORAGE VENDOR STORAGE VENDOR CLIPPER HI-PERFORMANCE STEEL SHELVING/FRAME SUPPLIED REGISTRATION EXPIRES 6/30/2013 ELEVATION D ELEVATION C ELEVATION B ELEVATION A BY STORAGE VENDOR(TYP). E STOCK ROOM ELEVATIONS 4 SECTION THRU MGR'S DESK 1 If(+ 2 LOOSE PVC TOP CAP � � 1/4"DIAMETER THRU BOLT 2'-6" 2'-0" TRIPP LITE 9U WALL MOUNT WALL CABINET W/2 DOORS ALL CAB.W/M/ VE SHELF A202 A202 RACK ENCLOSURE SERVER W/TOGGLE (TYP. OF 2j %J %% OF OV GC TO PROVIDE 3/" CABINET, PROVIDED BY F.T. PLYWOOD BLOCKING IN WAL L'OCCITANE, INSTALLED BY FOR INSTALLATION GC ° -- ° MAY f� C11 OF WALL MOUNTED _ COMBINATION DATA/ - -- — CABINETRY 1-6 `'�!'� VOICE CONNECTION FOR PAN HEAD SCREWS TO SHOPPERTRACK, DMX,L % %J SECURE STRAP LABEL ,o TELEPHONE 04 DUPLEX OUTLET FOR —_ 0 7 0 0 o (1) QUAD-OUTLETS FOR IT 3/4"X 2"POPLAR _ MICROWAVE - I.T.CABINET EQUIPMENT LEGEND EQUIPMENT, GC TO „ �� `��m PLYWOOD TRIM 2X4 M 8000aoo _..... 1. MODEM COORDINATE CONDUITS TO Gnu'oo-®®� ❑ 0 2. ROUTER SCREWED TO 2"X4". �� 6 000 0 0 o v 0 0 0 v �-- ACHEIVE ALIGNMENT AS 6"DIAMETER EXTENT OF WOOD 3. DMX EQUIPMENT SHOWN. ��, 4. AMPLIFIER FOR MUSIC SYSTEM (BY PVC TUBE HOLDER COUNTER TOP AS 9 DSL SH�PPERTRAK VENDOR) (1) DUPLEX OUTLET / MODEM AMP 5.SHOPPER TRACK EQUIP. METAL TRAP TYP OF SPECIFIED. GC TO � 4 z _ S — oo GC TO CONCEAL ALL POS 00000 m CUT IN FIELD. 6. POWER OUTLET STRIP (BY VENDOR) 4 2 = T1 7. PATCH PANEL (BY VENDOR) ,_� U r�� CONDUITS IN WALL (TYP). - ,N b 05-02-13 ISSUE FOR LANDLORD & PERMIT o o° 8. 24 PORT SWITCH PANEL (BY VENDOR) '= `�' _ 2 2 z o a a.s 3 9. 66 BOARD PROVIDED & INSTALLED BY ^ Q o ALL CONDUIT TO BE 1-1/2" 04-19-13 PRELIM PACKAGE E ' ® VENDORi� W/ PULL STRING TO RUN TO PVC BOTTOM CAP71: ISSUE DUPLEX OUTLET FOR `�'� _1--��� F1 o � �? �� �� I.T. CABINET GLUED IN PLACE M .� 7 4 0 DATE REVISIONS MINI-FRIDGE I I IKEA- NUMERAR SECTION SIDE ELEVATION END PANEL AS �O I 4 #500.864.16, 734'x 258', GC KEY PLAN: SPECIFIED (TYP) TO CUT ON SITE PER DETAILS f ,t p� K 4 PORT NETWORK JACK PLUMBING THIS TUBE CONTAINS STORE NOTE: PLINTH AS � x 7„ 1 7„ UNDER MANAGER'S DESK, CONTRACTOR MUST DRAWINGS AND IS NOT TO UPON COMPLETION OF PROJECT, G.C.TO b' <•f `£ ;� SPECIFIED (TYP). 1-O$ L— , 2'-34 1-� _ BE REMOVED WITHOUT THE PROVIDE A COMPLETE SET OF DRAWINGS -? fib EASE CABI T INSTALL HOUSE WIRING RUNS OPEN BSE CAB T PROVIDE AND ATTACH : �f , < ..... r9 Y Y fk :l g.. ffj9,n FROM MANAGER'S DESK TO f ff F, A LABEL WITH CLEAR CONSENT OF THE STORE FOR THE COMPLETED STORE x Y 5, <, I.T.CABINET (TYP). ( a�...y .,,,..... � ks � � , 41-611 41-011 ( ) TAPE) STATING: MANAGER. (ARCHITECTURAL, MECHANICAL AND g , 5.1 . � BREAK DESK MGR'S DESK ELECTRICAL) AND PLACE DRAWINGS INTO , =s Ey ELEVATION AT MANAGER'S DESK THANK YOU. DRAWING TUBE. ELEVATION AT BREAK DESK g s 3 3 3 0,...,:i..t„ S... 1.•.tr(5 N�1.}A\I!`1 R L..j BREAK DESK ELEVATION 8 DETAIL @ I .T. CABINET 7 ELEVATION @ MGR'S DESK 5 DRAWING TUBE DETAILS 2 r , � x £ 1 TE g yea fYs•�.ti�s,a �.� a sf„„�,l��ss£stt s.�s�'. r � UOCCITANE 1/2 " = 1'-0" 1-1/2 "—1'-0" 1/2 " = 1'-0" 3" = 11-0" SPACE #H6 ITEM MANUFACTURER i MODEL NUMBER REMARKS LOCATION: 100 a COUNTER TOP IKEA-'NUMERAR'#500.864.16,734'x 25$",GC TO CUT ON SITE PER DETAILS GC TO CUT IN FIELD;SEE ELEVATIO L kd%,j I FOR LENGTH EIS' PROVENCE WALL CABINET-2 IKEA-'AKURUM'30"x 30"UNIT,FRAME COLOR:BIRCH,FRONT:SOFIELUND WALNUT,LIGHT GREY BOUTIQUE #057 DOORS(1) ARTICLE#998.698.26 WASHINGTON SQUARE MALL CABINET#:AK W2 SPACE #H6 WALL CABINET- IKEA-'AKURUM'30"x 24"UNIT,FRAME COLOR:BIRCH,FRONT:SOFIELUND WALNUT,LIGHT GREY 9585 SW WASHINGTON SQ. RD. M/WAVE SHELF/1 DOOR(1) ARTICLE#898.698.17 TIGARD, OR 97223 CABINET#:AK WM BASE CABINET W/ IKEA-'AKURUM' 12"x 24, FRAME COLOR:BIRCH,FRONT:SOFIELUND WALNUT,LIGHT GREY AREA: 621 SF SHELVES(2) ARTICLE#:698.919.61 CABINET#:AK B1 SHEET TITLE: BASE CABINET IKEA-'PERFEKT SOFIELUND'24"x 30", FINISH:SOFIELUND WALNUT,LIGHT GREY BACK OF H END PANELS(4) ARTICLE#:602.012.70 ELEVATIONS WALL CABINET IKEA-'PERFEKT SOFIELUND'33", FINISH:SOFIELUND WALNUT,LIGHT GREY COVER PANELS(2) ARTICLE#:802.012.74 PROJECT NO. 13-1802 PLINTH (1) IKEA-'PERFEKT SOFIELUND'88"x 4-3/8", FINISH:SOFIELUND WALNUT,LIGHT GREY GC TO CUT IN FIELD TO FIT AT BASE SCALE: AS NOTED ARTICLE#:302.012.76 OF BASE CABINET UNITS(TYP) DATE: 04/17/13 CABINET HANDLES IKEA-'METRIK',4$",STAINLESS STEEL DRAWN BY: KJ [(3)SET OF 21 ARTICLE#:401.388.35 REVIEWED BY: AD NOTE:ALL BREAK DESK MATERIALS PROVIDED&INSTALLED BY GC. SHEET NO. NOT USED 6 BREAK DESK SCHEDULE 3 NTS NTS I F -. ,- , I � .,����:"�,,::�.,:e�,..�:,��4�.," -�,,,:-1-�. _,:.::�. : 1, ­ I. . � I.-I I I ­ .. ''. ­­, � �I ­:.:­.,...­,,:, ,. ..,:::�:,,��:�,,�,*,����,.:.�����:�:.,:�:.. ___i � .�­ _ � �.:,��.,:���:�'...,.,�;: ";.""%,�.'I ,. � .4 enne a r I . �� � ,�i�:..,�i,�.,.,��:��,��:�:.,�. . ::­ , ­: .- , I -�: . . , , �. ,.�,:.�........­ : 1 I ­.­­­­.­ ,,;:.q­­� ,:�'! �. �"­:�!!�i, - �­� :.___ ­­­. :,:,�11�:::, : : "'.. ­. ::­. ::.'�� ,Z5:�� ' I , 1- 1111. 1-11. 11 1, ­­­. .... , .1 �. . . � �� ..:��;�`,��,�',,�:::,��111 ., �4,,:��",�i�:i��_�!� ,. I ..: 1-', V".I..". . ­ ...­_-.�­ I .1 � ::.� �­�­��I ":_:, _,:­ .:��,��. - �11....... I . � 1 , ; :, I I ,.�­­ . ­_ .,1, ��;::,,���i�.,�������:,*���:.�!.::����:::.:�:�: � ,,. ,.. :,.�l::�,:,:.�:.����:��::..,:�:,.�1.1- ­��­.­., ­­,P�:i�.,.: '_� IV . _". . , �... I , �::"�,�::�',.:z:�,�,�� ,'.­�:,�..��_:.�.�4ele­ 1, , �"" , . , I � %. � .1 I , . _­_., ­:_ %.:,�__I_ 1111 : �­ 1 '1 -,: ,. _ � ,� � . "., ,�, _ ­. I ,: �:,�­ 11 .1 " %�..:";.,..��,�.,,�..�,.��,.,���:�.�:�:��-,,���:��������:�� , I ­�': e.:..o­ di:�,::�:�.4 " " :,: :: ,��. , :�� _ , ­:­ ­ 1: '�l''..;",.,:.:�� �,�".:::,." :''. � ,� t_ �.: �,�­],,�:. ,� ­*­ , , _':.:�,�. .­ . ,::..;: ­ .1 I., , � �,�4 . � - . . __ ��:,::;.:�:�,!:!�-���;�,.,i:::".,:,�,��,�� ,. -11111 - .. ...�."�ll,� 'll,���: ,.�.�.:�:%�,�,:: :�:�-,� �,.­, 01.. 11 '11 , - - F . _­­. 1. ­: , , '..."­ - ­ - - ., . '�:_:,:,. ,:,. ,, 14:1�,��: , ! .. � -, ,­,", ,.::i��;�,,�: I , I.......� ­­­.. �,: I ­�...I'��:�:::�:;��,.�: �, "�.:,��:�.''�!'!�Iii�.�.�,�,�,,��,,,�,�,:":� ,,� :_ ._':__. :! ­ �­::.­­,. �,� _',* �,��-,��-, � . �f�._ � �­_ :: .­­ 11 - .:� ­ - 1 ': � , - 1 ��� �i, :­ �_ ' ':1 ., ., . :" ':��' I.. " . . �'­;, - -_- -1:- I . �_ ::� %�,,�_ ­­ ­ I . 1�_:, :_ � ­,:�'�­:�., . 1:,�.,i�., ' '. F_:_% �:�_.I -_.,4 I , 1 , �: . ::�� :i.:�,, -'11 �� ,-",�­.�.-� �-�.�,: ��, ,.11�­­X. , : : �:: �: - " �*:�!��:..::­'__�,, �..", ,,, ­ K.'­�;�:!�_,' , W�!!:.".?, 11-1- � � " I ­­ .­ �:... . , 1,11.1 _�:�_:.�!�;�: ...I 1 . -­.­ ­­ ­­ , , EXIST.MALL BULKHEAD TO REMAIN. GC TO BE RESPONSIBLE FOR ANY Architecture DAMAGE THAT MAY OCCUR Urban Planning 3 DURING CONSTRUCTION (TYP). Store Design A300 360 Lexington Avenue /__,_ Mixed-Use New York,NY10017 EXISTING RECESSED LIGHTING AT Retail Development www.kennethpark.com UNDERSIDE OF CORNICE TO BE REMOVED; 1 _ GC TO PATCH &REPAIR 1 6 2 TO'LIKE NEW'CONDITION. EQ. EQ. MEP Consultant t r r '' e:rrt ! r,xyz r 7 <� 3 �>,, ,�k.�. .k i z T.O.E. 11 STOREFRONT ` -1 - � S O RONT ssa3 Ny 3 m k � J g£ ::J� � i .[ �. I __________1__-- F sr Y rf'1""rF r: € £ i::a Ufa. £ ; ,qMA .11 fi .. .Z"✓ ; EL. 11'-8" 1 . , . B.O.E.CORNICE 11 consulting engineer 1 don enn cons 'n n inee 1- p 9 9 II 2 635 Westport Parkway 1 THK BLE INT a a U S RA FCO LETTERS P Y PIN MOUNTED &LIT WITH LED Suite 300 1 N Grapevine,Texas 7 6051 E MALL CEILING; P O C ING, GC .?" 't' __ :,.. �n LIGHTING FROM BEHIND, ., .�- - - - TO PATCH RE1. ­111. N hone•817 410 2858 & PAIR PROVIDED A INSTALLED NSTALLED BY SIGN 4 - - F 7 A S REQUIRED V 1. 6 Fax:81 251 8411 Q % .1 1 t ENDOR � �::.. 1:4 �:"�:�:, I, �. , � 1. �, , :1 11, . ,�( I . f­_­:.��,��,�::.� �,,�:,�],���_:�: !;I I A300 3 % Is - SEAL: `V T;7. EL.o'-o" I HEREBY CERTIFY THAT THIS DRAWING T.O.E.I 4.1...;,� FT I GLAZING WAS PREPARED BY ME OR UNDER MY DIRECTSUPERVISION 1. G.C.TO CONFIRM THE CAND THAT I AM A . DULY RE I TERED LI E U G S N ED . C S ARCHITECT STRUCTURE OF EXISTING (E) STOREFRONT SYSTEM &ENTRY UNDER THE LAW F THE STATE MALL BULKHEAD;GC TO TO REMAIN U.O.N. FRAME& S O SAT OF PATCH &REPAIR AS MOLDING TO BE CLEANED & OREGON REQUIRED,V.I.F. PAINTED P-7 (TYP). RAISED PANELS ARCHITECTURAL REG. #: 3721 TO BE PAINTED P- TYP REFER TO 5 (TYP). REGISTRATION EXP EXPIRES :. 6/30/2013 EXISTING RAISED PANELS TO i = FINISH SCHEDULE FOR SPECS. ,�- BE REMOVED AND GLASS TO BE CLEANED & EXISTING RAISED PANELS TO REPLACED W/NEW PANEL = POLISHED AS REQUIRED &LEFT IN ,� W/P-5 POWDER COATED o "AS NEW"CONDITION. r�,�� BE CLEANED A _ AND PAINTED P-5. REFER TO FINISH GLOSS FINISH;SHEET METAL R- S OPEN TO SALES AREA I C. ' 1. 111. s _ 1 GC TO BE RESPONSIBLE FOR ANY SCHEDULE ON SHEET A002 (MIN. .080 THICK) oo ,, v t 11 I 1 B DAMA GE THAT MAY T � 6 OCCUR O THEA FOR SPEC. (TYP.) LAMINATED TO 3/4 t 2 E " I. PLYWOOD BY GC.ALL 1. GLAZING NUETRAL PIERS DURING FOP .. . - . P f . , 4 . A300 N TR T F . . . CO S UC ION TYP ( ) ,� EDGES TO BE SHOP1. w v FINISHED. REFER TO FINISH WHITE WINDOW VINYL'S FURNISHED & SCHEDULE FOR SPEC. NEW IN TALLED BY 1 N VEND R T . S S G YP . O ( ) PANELS TO BE MOUNTED s_w,�a NEWY xY WD.TRIM W P 7 4 4 W/Z-CLIPS.GC TO VERIFY L OCCITANE U SPRAY APPLIED ENAMEL PAINT . EN PROVSNCS IN FIELD ALL EXISTING i _ Sldncam•Bo `,m.P 0 t d (E) STONE BASE TO REMAIN.CLEAN v t11 FINISH AR UND NEW P-5 % I ll I PANELS REFER TO FINISH = PANEL SIZES (TYP). �o &POLISH AS REQUIRED TO LEAVE MAY Q --.icv 1 ,i I SCHEDULE FOR SPEC (TYP). IN NEW"CONDITION TYP ( ) CO O _ (TYP). SIGNAGE PROVIDED & 1.. 1IkE CID - -- INSTALLED BY SIGN '': _ r. „ LEASELINE - - ^icy EL.0'-O" 2 VENDOR. SIGN > � FLOOR FINISHED (E)STOREFRONT SYSTEM TO REMAIN NEW Y"xY"WD.TRIM W/P-7 SPRAY VENDOR TO SUBMIT ri�o N U.O.N. FRAME&MOLDING TO BE APPLIED ENAMEL PAINT FINISH SHOP DRAWINGS TO LL I NEW 1/4"x 1/4"WOOD TRIM AT CLEANED,STRIPPED,SANDED AND AROUND NEW P-5 PANELS REFER FOR APPROVAL PRIOR N PANEL EDGES, PAINTED P-7 (TYP). 9" 5'-1 1" 9" 4'-8" 5E 1 PAINTED W/SPRAY APPLIED ENAMEL TO FINISH SCHEDULE FOR SPEC(TYP). TO INSTALLATION. PAINT FINISH P-7(TYP).GC TO ENSURE 1 11 EXISTING DEMISING WALL FRAMING TO 15-0 _ SMOOTH UNIFORM APPEARANCE. REMAIN.GC TO PATCH AND REPAIR TO If at ADJACENT TENANT: Or ADJACENT TENANT: REFER TO FINISH SCHEDULE FOR SPECS. "AS NEW"CONDITION, PER APPROVAL NEWYaV''WD.TRIM W/ EDDIE BAUER BEN BRIDGE GLASS TO BE CLEANED&POLISHED AS OF UOCCITANE PM. P-7 SPRAY APPLIED REQUIRED&LEFT IN"AS NEW" ENAMEL PAINT FINISH CONDITION. AROUND NEW P-5 PANELS, REFER TO FINISH SCHEDULE 05-02-13 ISSUE FOR LANDLORD & PERMIT FOR SPEC (TYP). 04-19-13 PRELIM PACKAGE ISSUE LEASELINE -A A DATE REVISIONS TYP . CORNER SECTION 4 E 1/2"CLR.TEMPERED STOREFRONT ELEVATION( ) I KEY PLAN: GLAZING (TYP). _�__ - _._-_.s_<._.-_n_.-- -__.____-_--_.__- _ S k p� r' °#' Ya>^ i �f 3s s: S 3 � ----------_ __- �. {TZf f t� ,y � x .y '. � � i�. sy, � F �Y ;3e r 311 = 1 1.011 /211 = 1.011 a B Wrs E i 3 % j ,p 2kYt �3 fra r �Xs ?sn< zq sis r6 s'�g r .1 r r .T c r s r s "' 1,^ F s .c r a sr i s Y # z r< r s f s a s r r r rF ,h qv s r< .r 11: GENERAL g Sf >� G AL SIGNAGE NOTES: vU i t r. ? 1 is)y i t t s n i 11 � flu-- r I xRK- Lpg tr q "f r�varL`z ;�s '` sz F 1. 1.1-11111 11 .,ss 21 i i gra sy t , ,- r $r t", 3 rr ,.r:e$ir r,r 3'` fr err"' '' ° t 1. SIGNAGE CONTRACTOR TO SUBMIT ALL SIGNAGE SHOP DRAWINGS TO y r ARCHITECT AND LANDLORD AS PER LL SUBMITTAL CRITERIA PRIOR INSTALLATION. � : y � s � 1 2. SIGNAGE CONTRACTOR TO FABRICATE AND INSTALL ALL SIGNS AS PER LL SIGNAGE CRITERIA. 1 ., r Nip. x h s q 5 I x 3. STOREFRONT SIGNAGE IS TO BE SUBMITTED UNDER SEPARATE COVER FOR �k .t. �yJ"„ oe`�� MN ,k 6 LANDLORD APPROVAL F �y, £ 4. IF SIGNAGE REQUIRES A SEPARATE PERMIT. SIGN CONTRACTOR SHALL OBTAIN A311 �kM� F 3 ' f per +c, 2 s ✓ lx z SIGN PERMIT FROM THE LOCAL GOVERNING AUTHORITY PRIOR TO INSTALLATION. 1 a X'2'..� s", .. ; . LWI `�1'llflt"'t.,I1;).�. 5. SIGN CONTRACTOR MUST HAVE INSURANCE ON FILE WITH TENANT g COORDINATOR AT THE TIME OF CHECK-IN. A 02 UOCCITANE 6. GC TO VERIFY WITH "� H L OCCITANE PM IF STOREFRONT SIGNAGE G & LIGHTING SPACE #H6 DISPLAY TRACKS TO BE WIRED TO NEW DEDICATED CIRCUIT/TIMER OR IF TO BE > b� 1 . CONNECTED TO LANDLORD REQUIRED CIRCUIT/TIMER. �5i� o� LOCATION: I -1%­1., q FE11 - .­..,......_.1-11.,".:;::­;�,.: II . 1-1111.1.11 T= (E) STOREFRONT SYSTEM & ll' ­��:..:"1::':: §,�:,�:��,-�­1 ­".. .�:,�. %­�,,­:vl _1r__1%I :�::.�_­_ U .y ENTRY TO REMAIN U.O.N. 11-111, FRAME&MOLDING TO BE .�, - �:�..�%.­ I.. L 1 %('�..j dp"%I&'-" E CLEANED AND PAINTED T PROVENCE W/SPRAY APPLIED ENAMEL PAINT FINISH P-7 BOUTIQUE #057 (TYP). REFER TO FINISH LEASELINE WASHINGTON SQUARE MALL SCHEDULE FOR SPECS. _- ____ ____ 11 117771 7 . -. _ SPACE #H6 GLASS TO BE CLEANED & ____ POLISHED O SHED AS REQUIRED& Q 9585 SW WASHINGTON SQ. RD. Q LEFT IN"AS NEW" I 11 TIGARD OR 97223 CONDITION. % 1. ____ ..._ . .____._... ._._.___.. 7 3 .................... Ell, AREA: 621 SF L'OCCITANE - N ----- --- --- _ ___ __ r N SHEET TITLE: (E) STONE BASE TO q REMAIN. CLEAN &POLISH = AS REQUIRED TO LEAVE IN .. . ��,�, f,:� ,,. �,_.�f�.�,. ::,� >« L�,����>.y�,.,�. .��.�.s�. STOREFRONT "AS NEW"CONDITION. r - 1 PLAN & ELEVATION 1 1111 -- �,-0„ -_._-_ -�1 111 51_('� 11 5N 1it 2 2 2 2 �a J0 ol� 13'-s" PROJECT NO. 13-1802 I� II r I II EXIST. BASE BUILDING EXSTING ENTRY ROLLING (E) STOREFRONT SYSTEM &ENTRY TO REMAIN SCALE: 1/2 = 1 -0 . 9=110016112Mc ,,x,:, CONSTRUCTION TO REMAIN. GC GRILLE TO REMAIN, BE U.O.N. FRAME&MOLDING TO BE CLEANED, TO BE RESPONSIBLE FOR ANY REFURBISHED;SEE DOOR STRIPPED, PRIMED AND PAINTED W/SPRAY DATE: 04/17/13 DAMAGE THAT MAY OCCUR SCHEDULE FOR MORE INFO. APPLIED ENAMEL PAINT FINISH P-7 (TYP) FOR DURING CONSTRUCTION (TYP). SMOOTH UNIFORM APPEARANCE. REFER T O ( ) DRAWN BY: KJ FINISH SCHEDULE FOR O SPECS. LA T NOTE: C GLASS OBE ALL PLYWOOD USED IN THE CONSTRUCTION AND REPAIR OF THE CLEANED&POLISHED AS REQUIRED &LEFT IN "AS NEW" N REVIEWED BY: STOREFRONT SHOULD BE FIRE TREATED EXTERIOR GRADE CONDITION. AD PLYWOOD, (TYP). 1.111.1 SHEET NO. STOREFRONT NOTES 5 SECTION THRU GLAZING 3 STOREFRONT PLAN 2 -&$In% I - ____ - N.T.S. 111 _ 11-011 1/2 II = I 1_011 i i net en ar SCHEDULED WALL USG CEILING SYSTEM 12 GA GALVANIZED STEEL WIRE ACOUSTIC CEILING TILE FIRE PROOF & FIRE SEAL ALL PENETRATIONS Architecture Y4" PLENUM BOX AND SUPPORT UrbanPLENUManningDesign SYSTEM, REFER TO MEP DWGS. g 360 Lexington Avenue Mixed-Use New York,NY10017 ALL, G.C.SHALL _ Retail Development www.kennethpark.com VARIES DVERIFYI THAT ALL EXISTING - -- --- 12'-0"A.F.F. , SEE RCP ` B.O. LIGHT SOFFIT DEMISING WALLS ARE 1 HR RATED IF NOT G.C.SHALL UPGRADE C� tw MEP Consultant 2"X 2"STEEL ANGLE - I W r Is . LIGHT NOTE:A MINIMUM WALL ANGLE OF AT FASCIA MNTD FIXT RE U _ � a _ 11'-0"A.F.F. LEAST ATWO INCH HORIZONTAL LEG SHALL SEE RCP & ELECTRICAL DRAWINGS a .3y = B.O. CEILING @FRAGRANCE BE USED AT PERIMETER WALLS AND FOR TYPE & LOCATION. 3'-0" £ ' INTERIOR FULL HEIGHT PARTITIONS.THE PROVIDE BLOCKING & POWER 6"SUPPLY AIR DIFFUSER, REFER TO don enn consulting engineer �, p 9 9 MEP DWGS. FIRST CEILING TILE SHALL MAINTAIN 3/4 FEED AS REQUIRED (TYP). 635 Westport Parkway CLEAR FROM THE FINISH WALL SURFACE. Suite 300 Grapevine,Texas 76051 Phone:817-410-2858 MALL COMMON AREA SALES AREA SEAL: TYP . ACT CEILING DETAIL 4 TYPICAL CEILING SOFFIT DETAIL (@FRAGRANCE) 1 I HEREBY CERTIFY THAT THIS DRAWING WAS PREPARED BY ME OR UNDER MY 2„ DIRECT SUPERVISION AND THAT I AM A 6" = 1'-0" 1" = 1'-0" DULY REGISTERED/LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF OREGON 4ARCHITECTURAL REG. #: 3721 1 -3 VARIES 2%2"MTL.STUDS 16"O.C.TO REGISTRATION EXPIRES : 6/30/2013 4 N 82. Q 1 POSTER HANGER PROVIDED STRUCTURE ABOVE + Q V.I.F. - - BY L'OCCITANE, INSTALLED BRACE AS REQUIRED ' POS HANGER EXTENDS _ BY GC BEYOND WINDOW TABLE w 12 GA GALVANIZED x — i = _= _.-- __ - _ - t � {._ . T SALES SI E - O o J i FACE OF POSTER STEEL WIRE lil d 00 = Q ! PLENUM BOX AND SUPPORT . SEE RCP FOR LIGHT QUANTITY , "e� ; j `:baa F SYSTEM, REFER TO MEP DWGS. POSTER HANGER PROVIDED p w - - -` 5USG CEILING SYSTEM 4 00 BY L'OCCITANE, INSTALLED °° i SUSPENDED TRACK.SEE RCP 18�MTL.STUDS 16 O.C. TRACK LENGTH TH C G BY GC REFER TO SCHEDULE FOR :"� -_ - --- - PARTITION TYPE ``, Ar r- I + 12'-0"A.F.F. POSTER PROVIDED AND 4"SUPPLY AIR DIFFUSER, B.O. LIGHTING SOFFIT INSTALLED BY L'OCCITANE - - REFER TO MEP DWGS. 6-L COVE MNTD. LIGHT FIXTURE MAY 0 2 2013 -- - ---- -- -- NOTE: SEE RCP & ELECTRICAL --- - 1 1'-0"A.F.F. IF THIS DETAIL CAN'T BE DRAWINGS FOR TYPE & 8 ACHIEVED CONTACT ARCHITECT LOCATION. PROVIDE B.O. CEILING @ SKINCARE FOR ALTERNATE SOLUTIONS. BLOCKING &POWER FEED 11 3/4" LINE OF WALL BEYOND A400 AS REQUIRED (TYP). LIGHT POLES LOCATION 5 TYPICAL CEILING SOFFIT DETAIL (@SKINCARE) 2 EXISTING STOREFRONT.SE ----- --- - - -- --- -- - - ---- —-- -- - - - - ------ --- --- A300 FOR MORE 1" = 1'-0" 1" = 1'-0" 3 INFORMATION 05-02-13 ISSUE FOR LANDLORD & PERMIT 114 r 04-19-13 PRELIM PACKAGE ISSUE (3C 3'.MIN. DATE REVISIONS A400 WINDOW TABLE PROVIDED KEY PLAN: 1 X 1 9/16"X 1 s BY L'OCCITANE, INSTALLED BY GC KNURLED CHANNEL LU MOLDING ..,. ,y y 2&=1 r ,'.s,'ia�•.w.:% +a �:< �x .s..�.,s:;z..,. _zrR q r Rs e W * r:k : s u ( r.,h a .' m 5/8ii TH. GYP. kf, Q 8D. CEILING � Y pD 6 R r �er tl s§ s YRr 3 r t z < x L] Q Ll Q F �'&q PANEL FRAME 3 WIDE O OON ALL (4) SIDES. 5 � 04 , F 3 � .. .. .... .. .:. CLCL= S .j » ' 0 6 xX rTRs >. r s FF 8 MIN. ry �� a 3 ; r 7� -- - ----- 5/8'THICK 4 E ACCESS PANEL DOORV ' r � GYPBOARD CEILING w, :.,l"M TAPE & FILL NECCESSARY L'OCCITANE 0'-0"AFF FOR A SMOOTH FINISH Y FLOOR � � � _ � ��x�,�.� ��: �,��;�i� �;��,s�.,a., FINISHED SPACE #H6 LOCATION: = SECTION THRU WINDOW TABLE 3 NOT USED 6 SECTION 3" 1'-0" A EN PROVENCE BOUTIQUE #057 _- - -- _ - --_ --- ----- WASHINGTON SQUARE MALL 1" = 1'-0" 1" = 1'-0" 2'-0" SPACE #H6 SUPPORT 3" 1'-6' 3" _ 9585 SW WASHINGTON SQ. RD. CHANNEL (U.O.N.) TIGARD, OR 97223 1"X 1 9/16"X 1" "' I— � AREA: 621 SF KNURLED CHANNEL MOLDING E::] El R = 1%" 2 SHEET TITLE: PANEL FRAME 3"WIDE0 0 ON ALL (4) SIDES. CEILING o ­ o z D ELS N ACCESS PANEL 8 MIN. 3A PROJECT NO. 13-1802 DOOR TAPE& FILL AS �OO SCALE: AS NOTED NECCESSARY FOR A SMOOTH FINISH DATE: 04/17/13 c� Y$'THICK GYP. BD. CEILING DRAWN BY: KJ REVIEWED BY: AD DETAIL 6" = 1'-0" C PLAN lY2" = 1'-0" B SHEET NO. NOT USED 9 NOT USED 7 ACCESS PANEL DETAILS 3 AS NOTED 2'-2$' 2'-11 1. 2'-25,. 2'-3211 END PANEL EPOS UNIT WRAPPING MODULE EPOS UNIT END PANEL END PANEL 40 G.C.TO DRILL HOLE IN SIDE OF FIXTURE BEHIND TRANSLUCENT et ,- PLASTIC PANEL TO ACCOMMODATE WIRING FOR NEW LIGHTING. ALL WIRES MUST BE HIDDEN FROM SALES AREA. NOTE: DO NOT DRILL END FIXTURES G.C.TO SECURELY FIX - '�` d w Architecture FRAGRANCE/SKINCARE UNIT UPPER G.C.TO FIELD CUT FIXTURE PROVIDED BY L'OCCITANE L0100 TO REMOVE RUST FINISH IRON BAR CROSS BRACE allE PROVENCE N PROVENCE Urban Planning SECTIONS TO WALL. G.C.TO PROVIDE LIGHT FIXTURE TO BE BEHIND TRANSLUCENT PLASTIC PANEL. ALL ROUGH Store Design BLOCKING AS REQUIRED-SEE NOTE: MOUNTED TO ILLUMINATE 360 Lexington Avenue EDGES MUST BE GROUND SMOOTH AND PAINTED TO Mixed-Use New York,NY 10017 BLOCKING FOR WALL FIXTURES. PRODUCT BELOW - _— MATCH THE IRON FINISH (SKINCARE UNIT ONLY) (TYP). Retail Development www.kennethpark.com JESCO MOUNTING CLIP &a MA ffis ad 0�1 WA__ ME - M G.C.TO PROVIDE (1) DUPLEX (83"AFF) G.C.TO PROVIDE (2) DUPLEXS (22"&83" 'SG-MC-VH' PROVIDED BY FOR EVERY GROUP OF FRAGRANCE AFF) FOR EVERY GROUP OF SKINCARE GC (TYP) MEP Consultant WALL UNIT LIGHT FIXTURES. WALL UNIT LIGHT FIXTURES. OUTLETS TO BE HIDDEN FROM SALES OUTLETS TO BE HIDDEN FROM SALES AREA. r,xy s,Ff _ OWN x; s : , ..... ..... .. r"'z. ..f3:,�.., � �. �" �za',T-`"F .aSS3. Sim s•+e`�' AREA. NOTE: G.C.TO REMOVE EXISTING NOTE: G.C.TO REMOVE EXISTING o0 EUROPEAN FIXTURES AND REPLACE WITH EUROPEAN FIXTURES AND REPLACE WITH NEW SEE ELEC DWGS FOR SPECS (TYP). NEW SEE E W FORSPECS) ( ) ( ) LEC DWGS O ( / '. ...... ....., '. • '�„E� �” . �» „?�rl� �ii�':�i'n`E4':R�� :2 A�B'3T d� ', r— F �'" ¢�,� x'��:, ., � a£�s, :'t"S - N.0`tu,�x:�•, ads," N - don penn consulting engineer 0 635 Westport Parkway Suite 300 1 - - Grapevine,Texas 76051 A ! Phone:817-410-2858 11 H 11 Fax:817-251-8411 I \ SEAL: ^ice DETAIL A FRONT ELEVATION (SALES SIDE) SIDE ELEVATION I HEREBY CERTIFY THAT THIS DRAWING WAS PREPARED BY ME OR UNDER MY -! ANGLE TO MOUNT LIGHT 2'-28" 2'-11 2'-2$" DIRECT SUPERVISION AND THAT I AM A FIXTURE&CUP TO END PANEL EPOS UNIT WRAPPING MODULE EPOS UNIT END PANEL DULY REGISTERED/LICENSED ARCHITECT FIXTURE, PROVIDED BY LIGHTS AT CASHWRAP, SEE RCP UNDER THE LAWS OF THE STATE OF GC. - & LIGHT FIXTURE SCHEDULE G OREGON �— A 102. ARCHITECTURAL REG. #: 3721 REGISTRATION EXPIRES : 6/30/2013 ---- -- ANE 77 CELLOPH � A�f E NOTE: FIXTURES ( ALL WOOD FIXTURES SHALL BE KILN-DRIED, SAMPLES c t MILL QUALITY FINISH AND ALL WOOD SHALL RECEIVE A FIRE RETARDANT COATING OR r 0 f a O p, TREATMENT WHERE REQUIRED BY CODE. r '��` B EPOS UNIT, WRAPPING UNIT& _ OPP. � k 4 ; i I . . \ END PANELS PROVIDED BY V) 0 \ L'OCCITANE, INSTALLED BY G.C. N PAPER DETAIL B BAGS � �� O - OX DATA & POWER OUTLETS. SEE NOTE: OUTLET TO BE MEP &A]03 FOR DETAILS. LOCATED BEHIND OFFICE OFFICE NOTE: G.C.TO RUN RIGID CONDUIT FROM JAY 2 2013 1'-9�" 1' 85" DRAWER UNITS ONLY, 0 0 0 o BOXES AT WALL TO OUTLETS ATTACHED TO THE 4 4 2-7 g NOT GLASS. - INTERIOR OF THE CASHWRAP. REFER TO 01 PRINTER `- N PRINTER ENGINEERS ELECTRICAL PLANS FOR FRONT ELEVATION SIDE ELEVATION FRONT ELEVATION SIDE ELEVATION r ADDITIONAL INFO (TYP). FRAGRANCE UNIT SKINCARE UNIT BACK ELEVATION EPOSUNIT (CASHWRAP) FIXTURE DETAILSFRAGRANCE & SKINCARE FIXTURE DETAILS 5 1 3/411 = 11-01f III = 11-011 05-02-13 ISSUE FOR LANDLORD & PERMIT METAL EPDXY FINISH 04-19-13 PRELIM PACKAGE ISSUE 1'-11$"(595mm) /2'-8"(816m ) RAL48017 (TYP). DATE REVISIONS KEY PLAN: cc . C E METAL EPDXY FINISH �o / •o 3 f � d , RSk _ 9 F, G.C.TO PROVIDE (1) DUPLEX (83 AFF) FOR EVERY GROUP OF iF3 .s r z r € gy u, r.rp t rrr^- 4 1'-1 131, 595mm / SKINCARE WALL UNIT LIGHT FIXTURES. 8 ( ) RAL#8017 (TYP). / 00 / °0g 00 O� t] Asa sz h n it s s OUTLETS TO BE HIDDEN FROM SALES AREA. NOTE: G.C. TO % N % N / / REMOVE EXISTING EUROPEAN FIXTURES AND REPLACE WITH NEW (SEE ELEC DWGS FOR SPECS) / % ys /q �" O ° LO LO 12 CONNECTING CORD, ( L0 LF) 1) J2 / rii� % �i� �W H£ m yt y". ? # 4(f1 T,jt-t�A rry a�if qf. 7s�n. TYP. r , (1) J2 l J2 POSTER FRAME UNITS G.C.TO PROVIDE SCREWS L'OCCITANE O 1'-71.- / PROVIDED BY L'OCCITANE, TO MATCH FRAME (TYP.) SPACE #H6 2 / INSTALLED BY G.C. (TYP). E / E LOCATION: / E FRONT ELEVATION SIDE ELEVATION r<100 0 / 0, O N cv 1 ' �� ('14 N 1 J2 d v (1) J2 POSTER FRAME DETAILS 2 EN PROVENCE (1) J2 BOUTIQUE #057 (1) J2 / / 1 f1 = 1 1_011 WASHINGTON SQUARE MALL (1) 241"CONNECTING (1)_J2 0 / Or SPACE #H6 / METAL EPDXY FINISH 9585 SW WASHINGTON SQ. RD. CORD,TYP. (1) J2 31_101RAL#8017 (TYP). Z 2- TIGARD, OR 97223 / 621 F AREA: S MIRROR UNIT RECTANGULAR FRAME / i HE LE' UNIT PROVIDED BY L'OCCITANE, / SHEET TIT INSTALLED BY G.C. (TYP). FIXTURE FRONT ELEVATION SIDE ELEVATION j G.C. TO PROVIDE SCREWS TO MATCH - j - DETAILS FRAME (TYP.) MOSAIC CHARTER �0 / / PROJECT NO. 13-1802 G.C.TO PROVIDE (1) DUPLEX (22"AFF) FOR EVERY GROUP G.C.TO INSTALL (3) J2 OF SKINCARE WALL UNIT LIGHT FIXTURES. LIGHTING FIXTURES FOR OUTLETS TO BE HIDDEN FROM SALES AREA. NOTE:G.C.TO EACH SKINCARE FIXTURE / SCALE: AS NOTED REMOVE EXISTING EUROPEAN FIXTURES AND REPLACE WITH (SEE A-102 FOR SPECS) NOTE: BLOCKING FOR WALL FIXTURES NEW (SEE ELEC DWGS FOR SPECS) GC TO PROVIDE ALL NECESSARY FIRE RETARDANT DATE: 04/17/13 BLOCKING REQUIRED FOR ALL WALL MOUNTED FIXTURES. GC MUST PATCH AND REPAIR AT DEMISING WALL TO DRAWN BY: KJ s MAINTAIN FIRE RATING.SEE FIXTURE DRAWINGS FOR MOSAIC & CHARTER UNIT MORE INFORMATION, EXACT DIMENSIONS AND FURTHER PROVIDED BY L'OCCITANE, FIXTURE DETAILS. INSTALLED BY G.C. (TYP). REVIEWED BY: AD FRONT ELEVATION SECTION SHEET NO. PERIMETER FIXTURE LIGHTING DIAGRAM 6 FRAME DETAILS 4 MOSAIC & CHARTER DETAILS 3 NTS 111 = 11—Oft 11 = 1 1_011 i i I<ennet ark NOTE: BLOCKING FOR WALL FIXTURES EXISTING COLUMN ENCLOSURE GC TO PROVIDE ALL NECESSARY FIRE RETARDANT Architecture BLOCKING REQUIRED FOR ALL WALL MOUNTED FIXTURES. Urban Planning GC MUST PATCH AND REPAIR AT DEMISING WALL TO Store Design MAINTAIN FIRE RATING. SEE FIXTURE DRAWINGS FOR Mixed-Use 360 Lexington Avenue New York,NY 10017 MORE INFORMATION, EXACT DIMENSIONS AND FURTHER Retail Development www.kennethpark.com FIXTURE DETAILS. MEP Consultant CUSTOM COLUMN ENCLOSURE BY L OCCITANE. INSTALL BY G.C. (TYP.) E E'b,E�Er don penn m consulting engineer 2A _ 2C 635 Westport Parkway -1 Suite 300 _ _ Gra evine,Texas 76051 A402 r � � � � A402 p Phone:817-410-2858 Fax:817-251-8411 (^ SEAL: I HEREBY CERTIFY THAT THIS DRAWING WAS PREPARED BY ME OR UNDER MY 71DIRECT SUPERVISION AND THAT I AM A 2 DULY REGISTERED/LICENSED ARCHITECT op UNDER THE LAWS OF THE STATE OF OREGON ARCHITECTURAL REG. #: 3721 REGISTRATION EXPIRES : 6/30/2013 2 A A402 , PLAN K NET I 113K NJ OF O AY 022013 COLUMN DETAILS 1 - -1/2 If _ 1_0„ i 05-02-13 ISSUE FOR LANDLORD & PERMIT LINE OF EXISTING COLUMN 04-19-13 PRELIM PACKAGE ISSUE TO BE PAINTED P-1 . SEE FINISH SCHEDULE. (TYP.) 0 DATE REVISIONS - 000000 0 0 0 0 00 0 n_()_,q- 000KEY PLAN: 1. tf { �� tI'( oo �- 00 00 00 010 11 f '6 $dSu q O O O O O O O O no O s i y O O • O O /y JFc6 CUSTOM COLUMN ENCLOSURE O O O O 701 O O J Nf= Jty k £ ✓ 37f BY L OCCITANE. INSTALL BY G.C. 70 57 0 0 0 0 0 0� o o zs t01 iNORI TROM 7LL L'OCCITANE 00 00 0 o O o 0 00 0o SPACE #1 00 00 0 0 0 0 00 00 LOCATION: AV O O O O r O O O O O r O O O Gis 11 AL Llocu TO O 7-0 O O N PROVENCE 70 0 0 0 0 0 0 0 0 0 o BOUTIQUE #057 WASHINGTON SQUARE MALL 70 0 0 0 o O o 0 0 0' 0 0 SPACE #H6 7 -1 9585 SW WASHINGTON SQ. RD. 0 0 0 00 0 0 0 0 0 0 o TIGARD, OR 97223 O 70) E AREA: 621 SF TO 0 0 0 0 0 0 TO 0 0 SHEET TITLE: O 7LjT 11 00 57211FIXTURE L L L L L � 0000000 0 0 0 0 0 0 ° ° Oo D ETAILS PROJECT N0. 13-1802 LINE OF EXISTING COLUMN x,_32„ x,_72„ x,_32„ TO BE PAINTED P-1 . SEE o o _ o SCALE: AS NOTED FINISH SCHEDULE. (TYP.) � � r DATE: 04/17/13 DRAWN BY: KJ ELEVATION A ELEVATION B ELEVATION C REVIEWED BY: AD SHEET NO. NOT USED 3 COLUMN DETAILS 2 NTS1" = 1'-0" l - - ennet Architecture Urban Planning Store Design 360 Lexington Avenue I Z Qy Mixed-Use New York,NY10017 Retail Development www.kennethpark.com I 101 STOCK ROOM 100 SALES AREA MEP Consultant 12'-0" ACT I 11'-0" GWB-P6 I don penn consulting engineer 635 Westport Parkway Suite 300 (N) CEILING MOUNTED REMOTE j Grapevine,Texas 76051 (N) THERMOSTAT(S) TO BE TEMPERATURE SENSOR(S) TO BE Fax:817-251-8411 85$ LOCATED AS REQUIRED III LOCATED AS REQUIRED. I I NEW ACCESS PANEL LOCATION TO BE • i 6 4 ;f COORDINATED ONSITE SEAL. ® - - - - — ® � —' - - W/L'OCCITANE PM & ARCHITECT(TYP). I START POINT I FOR ACT A I i C1.4c� T` T I CL WIN : I I I I I ; . cc — - - - - -- - - - - - --- - - - - —19 0=11 ----- - ----- - ---- Q IUJI , : p CM 21 17 3 \� r^ i a k �7 r r , -- __; �_" - - -- __4L_ c- : - i - jY NEW 16 x12 .5) { I /�� 4� I V/�V-1 ` L -� J� J _ L J 3 yl '\x__11 F-fid-__;. �__.(\__+fit Ik-- I i k RI i �i r ► r , r r �,` � _ __:� a^o z I ! I l ST CL ENTRY 1 r 1 Z � - - --- - _ I _ i — — : i 's �_--- --- - -— ...... : I , I : : u u L1IT � = ; I LINEAR DIFFUSER IN EXISTING RECESSED DOWN LINEAR DIFFUSER IN TOP OF I ! 6 I FACE OF SOFFIT(TYP). LIGHTS IN BOTTOM OF COVE (TYP).SEE MEP i DRAWINGS FOR DETAILS - �� I SEE MEP DRAWINGS CORNICE TO BE REMOVED; FOR DETAILS GC TO PATCH &REPAIR GWB-P1 CORNICETO'LIKE NEW' CONDITION (TYP). 12'-0" GWB-P6 8'-10" GWB-P6 05-02-13 ISSUE FOR LANDLORD & PERMIT 04-19-13 PRELIM PACKAGE ISSUE "TGC SHALL ENSURE THE MECHANICAL SYSTEM IS BALANCED WITH THE FRONT DOORS OPEN". DATE REVISIONS EACH DUCT/SMOKE DETECTOR MUST HAVE A KEY PLAN: REMOTE KEY OPERATED RESET/TEST DEVICE urh5 F,�:u /�„'r�r'r �ys y G.h F $ � y�9r?.^•. ai 4 �' /'4Y S.� h f t!,7iG S' "4 e!� 7 §' 4 � '✓ 54 MOUNTED WITHIN THE TENANT SPACE AND ANOil 1 ADDRESSABLE RELAY MODULE. USE LANDLORD'S ie ,._ t f”`p y x k 9'd 5�� F wr'tr>�X./•,r DESIGNATED CONTRACTOR FOR CONNECTIONS rr3'���' r���• r �, y,, � s;Y'i r f THE MAIN FIRE ALARM LOOP 3' J_ s is Y.a yr�ryy�r r.Y' N4 RUST�ON! MECHANICAL PLAN 1r / z ✓ L'OCCITANE 1/4" = 1'-0" SPACE #H6 A. COORDINATE LOCATIONS OF DIFFUSER GRILLES W/ARCH REFLECTED CEILING LOCATION: SUPPLY/RETURN DIFFUSER SCHEDULE SYMBOL SYMBOL DESCRIPTION PLAN. 1 PROVIDE NEW T-STAT AS REQUIRED AT 48"A.F.F.ALSO PROVIDE NEW REMOTE -_ - SENSORS INSTALLED AT RETURN AIR GRILLE.VERIFY LOCATION WITH B. SUBMIT COPIES OF TEST&BALANCE REPORT TO LANDLORD,OWNER & CONSTRUCTION MANAGER PRIOR TO INSTALLATION.VERIFY ANY&ALL"B.M.S." MAX. NOISE DAMPERS REF. NOTES ® SUPPLY DIFFUSER O THERMOSTAT ENGINEER. MANUFACTURER MODEL NO. TYPE FINISH SIZE INTERFACE REQUIREMENTS W/LANDLORD. L' OCCITAN j CRITERIA FIRE VOLUME NOTE C. ADJUST DISCHARGE PATTERN OF THE DIFFUSER FOR A VERTICAL FLOW. NAILOR 61 DVO SD-1 ALUM.OFF-WHITE 12'x6" 35 X 1,2 1. SIDEWALL REGISTER D. REMOVE ALL EXISTING FIRE SPRINKLER HEADS AND DROP LEGS.PROVIDE NEW 2 EXISTING VAV UNIT VERIFY LOCATION IN FIELD. COORDINATE ALL CONTROLS EN PROVENCE HORIZONTAL BLADE 15 DEG. ® SUPPLY DIFFUSER OD DUCT DETECTOR HEADS OF TYPE SHOWN. REWORK BRANCHES AND MAINS AS REQUIRED FOR AND REQUIREMENTS WITH LANDLORD PRIOR TO BID. TITUS OMNI SD-2 ALUM.OFF-WHITE 24"x24" 35 X DOWN. NEW ELEVATION. HEADS TO BE UPRIGHT,SEMI-RECESSED OR FULLY RECESSED. BOUTIQUE #057 NAILOR 71 DVO RG-1 ALUM.OFF-WHITE 12'x6" 35 X 2. OPPOSED BLADE DAMPER RETURN AIR GRILLE —� VOLUME DAMPER FULLY RECESSED TO BE PROVIDED WITH WHITE COVERS UNLESS OTHERWISE WASHINGTON SQUARE MALL ® NOTED. FIRE PROTECTION WORK TO BE PROVIDED BY LANDLORD 3 T.G.C.TO SUPPLY AND INSTALL NEW SUPPLY DUCTWORK.AS INDICATED. TITUS 350FL I RG-2 ALUM.OFF-WHITE 24'x24" 35 X DUCT CONN.TO CONTRACTOR. SPACE #H6 RETURN AIR GRILLE RECTANGULAR DUCT E. CONTRACTOR SHALL COMPLETELY REMOVE FROM THE PREMISES ALL 4 COORDINATE THE MALL SUPPLY AIR DUCT LOCATION WITH MALL OPERATIONS 9585 SW WASHINGTON SQ. RD. W/SPIN-IN FITTING& EQUIPMENT, PIPING, DUCTWORK, DIFFUSERS, GRILLES,CONTROLS,CONTROL MANAGER. TIGARD, OR 97223 VOLUME DAMPER WIRING, ETC.AND ALL ASSOCIATED SUPPORTS, BRACING, PADS,ETC.NOT FKI EXHAUST FAN BEING REUSED OR SHOWN TO REMAIN WHETHER IN THE DEMISED SPACE,ON PROVIDE YOUNG REGULATORS WHERE ACCESS IS LIMITED. �-- TYPE OF AIR DEVICE THE ROOF OR OTHERWISE LOCATED OUTSIDE THE DEMISED SPACE.DO NOT5AREA: 621 SF EXISTING MECHANICAL EQUIPMENT SCHEDULE (VAV SYSTEM) FIRE PER �-- AIR QUANTITY (CFM) ABANDON. REFER TO ARCHITECTURAL DEMOLITION PLANS. 6 EXISTING OPENING IN DEMISING WALLS FOR RETURN AIR PATH. F. DIFFUSER RUNOUT EQUAL TO DIFFUSER CONNECTION UNLESS OTHERWISE VERIFY EXISTING LOCATIONS IN FIELD. REPORT ANY LOCATION CONFLICTS SHEET TITLE: PLAN MODEL SPECIFIED. WITH THE ARCHITECT. MIN. MIN INLET NOTES G. SPRINKLER HEAD LOCATIONS ARE FOR REFERENCE ONLY.THE FINAL MECHANICAL MARK MANUF. NUMBER CFM CFM PD DIA. ELECT. HEAT THERMOSTAT 5 LOCATIONS NEED TO BE INSTALLED PER CODE AND ARE THE RESPONSIBILITY OF SYMBOLSAND LEGENDS THE CONTRACTOR WHO INSTALLS. 1. COORDINATE ALL REQUIREMENTS H. REFER TO ARCHITECTURAL PLANS FOR CEILING HEIGHTS. PLAN VAV-1 TEMPMASTER HGFS 900 210 .25 10 7.5 KW AND FEES WITH LANDLORD PRIOR TO I. ALL EXPOSED ROUND DUCT SHALL BE PAINTABLE. BID. NTS J. PROVIDE YOUNG REGULATORS WHERE ACCESS IS LIMITED PROJECT NO. 13-1802 HVAC WORK TO CONFORM TO ALL APPLICABLE STATE, LOCAL AND REGULATORY AGENCY CODE IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT, LANDLORD AND REQUIREMENTS.TGC SHALL USE LANDLORD APPROVED AIR BALANCING CONTRACTOR.REPORT SHALL TENANT OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN EXISTING CONDITIONS INCLUDE OUTSIDE AIR CFM AND TOILET EXHAUST CFM. PRIOR TO COMMENCEMENT OF WORK. SCALE: 1/4" = 1'-0" = MECH . NOTES 3 BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND DATE: 04/17/13 SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK.THE BASE BID SHALL REFLECT NTS D LOCAL CODES MODIFICATIONS TO SYSTEMS AND DEVICES AS REQUIRED BY STATE AN O DRAWN BY. KJ WHETHER INDICATED OR NOT ON CONTRACT DOCUMENTS.THE SUBMISSIONS OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION AND COMPLIANCE WITH GOVERNING CODES/ SALES AREA 621 x.3= 186 REVIEWED BY: BB REQUIREMENTS HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT,OR MATERIALS STOCK AREA 134 x.15=20 REQUIRED OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN,HAD TOTAL REQUIRED=206 OSA SHEET NO. AN EXAMINATION AND CODE REVIEW BEEN MADE,WILL NOT BE ALLOWED. MECHANICAL SCHEDULE 7 CONTRACTOR NOTES 6 OSA CALCULATION 4 MECH . NOTES BY SYMBOL 2 NTS NTS NTS NTS PROVIDE EQUIPMENT INDICATED ON THE DRAWINGS,AND AS REQUIRED FOR A COMPLETE FUNCTIONING SYSTEM. DUCT LINER (ALL RECTANGULAR RETURN DUCT): PROVIDE MINIMUM 1"THICK,3 PCF DENSITY, NEOPRENE COATED, ken neth ark LONG TEXTILE FIBER TYPE DUCT LINER, WITH COATING ON THE AIR STREAM SIDE CONFORMING TO NFPA 90A.DUCT DEFINITIONS: FURNISH MEANS TO SUPPLY AND DELIVER TO PROJECT SITE, READY FOR INSTALLATION. INSTALL LINER ADHESIVE SHALL BE AS RECOMMENDED BY DUCT LINER MANUFACTURER,AND SHALL COMPLY WITH ASTM MEANS TO PLACE IN POSITION AND MAKE CONNECTIONS FOR SERVICE OR USE. PROVIDE MEANS TO FURNISH C-916. DUCT LINER FASTENERS SHALL COMPLY WITH SMACNA"HVAC DUCT CONSTRUCTION STANDARDS", LATEST EDITION.THERMAL CONDUCTIVITY SHALL BE EQUAL TO OR LESS THAN 0.26 AT 75°F. AND INSTALL, COMPLETE AND READY FOR INTENDED USE. Architecture Urban Planning WARRANTY: PROVIDE LABOR AND MATERIALS TO REPAIR OR REPLACE DEFECTIVE PARTS AND MATERIALS AS Store Design REQUIRED FOR ONE YEAR AFTER SUBSTANTIAL COMPLETION OR OWNER ACCEPTANCE OF THE COMPLETED ROUND VOLUME DAMPERS: PROVIDE MINIMUM 20 GAUGE GALVANIZED STEEL FRAME AND BLADES,MINIMUM Mixed-Use Ne Lexington Avenue New York,NY 10017 PROJECT. PROVIDE A SEPARATE LINE ITEM DEDUCT AMOUNT ON THE PROPOSAL FORM TO DELETE WARRANTY 3/8"SQUARE STEEL AXLE,MOLDED SYNTHETIC BEARINGS,WITH LOCKING POSITION REGULATOR. REGULATOR Retail Development www.kennethpark.com SERVICE,AT THE OWNER'S OPTION. SHALL BE POSITIONED WITH SHEETMETAL BRACKET BEYOND DUCT COVERING.WHERE POSITIONING REGULATOR IS NOT ACCESSIBLE, PROVIDE COUPLING AND EXTENSION ROD WITH REGULATOR FOR CEILING OR WALL COORDINATION: COORDINATE WITH THE WORK OF OTHER TRADES, EQUIPMENT FURNISHED BY OTHERS, INSTALLATION,AS REQUIRED. MEP Consultant REQUIREMENTS OF THE OWNER,AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. RECTANGULAR VOLUME DAMPERS: PROVIDE MINIMUM 16 GAUGE GALVANIZED STEEL CHANNEL FRAME, 16 ` DUCT DIMENSIONS: UNLESS OTHERWISE NOTED, DUCT DIMENSIONS ON THE DRAWINGS ARE INSIDE CLEAR GAUGE GALVANIZED STEEL BLADES, MINIMUM 1/2"HEXAGONAL AXLE, BOLDED SYNTHETIC BEARINGS,WITH 3/8" DIMENSIONS. SQUARE PLATED STEEL CONTROL SHAFT. LINKAGES SHALL BE CONCEALED IN THE FRAME.OPERATING SHAFT SHALL EXTEND BEYOND FRAME AND DUCT TO A LOCKING QUADRANT WITH ADJUSTABLE LEVER.MAXIMUM BLADE WIDTH SHEETMETAL DUCTWORK: PROVIDE SHEETMETAL DUCTWORK FABRICATED AND INSTALLED IN ACCORDANCE WITH SHALL NOT EXCEED 6". ASHRAE AND SMACNA STANDARDS, FOR 1"W.G. PRESSURE CLASS,SEAL CLASS"A".SHEETMETAL SHALL BE m m GALVANIZED SHEET STEEL OF LOCK FORMING QUALITY,WITH G90 ZINC COATING.SHEET STEEL SHALL COMPLY don pens a consulting engineer WITH ASTM A653 STANDARD SPECIFICATION FOR STEEL SHEETMETAL,ZINC COATED (GALVANIZED) OR ZINC-IRON DUCT TURNING VANES: PROVIDE FABRICATED TURNING VANES AND VANE RUNNERS,CONSTRUCTED IN 635 Westport Parkway ALLOY-COATED (GALVANIZED) BY THE HOT DIP PROCESS,AND A924 STANDARD SPECIFICATION FOR GENERAL ACCORDANCE WITH SMACNA"HVAC DUCT CONSTRUCTION STANDARDS".PROVIDE TURNING VANES Suite 300 REQUIREMENTS FOR SHEET, METALLIC-COATED BY THE HOT DIP PROCESS.ALL ANGLE IRON USED FOR SUPPORT CONSTRUCTED OF CURVED BLADES,SUPPORTED WITH BARS PERPENDICULAR TO BLADES,AND SET INTO SIDE STRIPS Grapevine,Texas 76051 SHALL BE GALVANIZED.CONNECTIONS TO WALLS OR FLOOR SHALL BE AIR TIGHT WITH ANGLE IRON AND SUITABLE FOR MOUNTING IN DUCTWORK. FOLLOW SMACNA GUIDELINES FOR SPACING SUPPORT,AND Phone:817-410-2858 CAULKING.SEAL ALL DUCT SEAMS,TRANSVERSE AND LONGITUDINAL,AIR TIGHT. PROVIDE TURNING VANES AT ALL CONSTRUCTION.ALL BLADES SHALL BE DOUBLE THICKNESS AIRFOIL TYPE. Fax:817-251-8411 U.L. ° 90ELBOWS. FLEXIBLE DUCT CONNECTORS: PROVIDE LABELED 30 OUNCE NEOPRENE COATED FIBERGLASS FABRIC DUCT i SEAL: CONNECTORS AT DUCT CONNECTIONS TO ALL VIBRATING EQUIPMENT. TRAPEZE DUCT HANGERS:PROVIDE MINIMUM 1"X 2"X 1"X 18 GAUGE CHANNELS WITH MINIMUM 1"X 18 GAUGE STRAPS TO STRUCTURAL SUPPORT. DUCT ACCESS DOORS: PROVIDE HINGED ACCESS DOORS IN DUCTWORK WHERE REQUIRED FOR ACCESS TO ROUND SHEETMETAL DUCT: PROVIDE SPIRAL SEAM (ALL SIZES) OR SNAP LOCK (DUCT SIZES UP TO 10") GALVANIZED EQUIPMENT. PROVIDE INSULATED ACCESS DOORS FOR INSULATED DUCTWORK.CONSTRUCT OF SAME OR THICKER STEEL COMPLYING WITH SMACNA STANDARDS.SPIRAL SEAM DUCTWORK SHALL HAVE SMACNA SEAM TYPE RL-1. GAUGE SHEETMETAL AS DUCT IN WHICH IT IS INSTALLED.PROVIDE FLUSH FRAMES FOR UNINSULATED DUCTS,AND EXTENDED FRAMES FOR EXTERNALLY INSULATED DUCTS. PROVIDE CONTINUOUS HINGE ON ONE SIDE,WITH ONE FLEXIBLE DUCT: PROVIDE FACTORY ASSEMBLED CLASS 1 AIR DUCT (UL 181) WITH 1"THICK 1 PCF FIBERGLASS HANDLE-TYPE LATCH FOR ACCESS DOORS 12"HIGH AND SMALLER,AND TWO HANDLE-TYPE LATCHES FOR LARGER ©�A�,, ACCESS DOORS. INSULATION AND REINFORCED OUTER PROTECTIVE COVER/VAPOR BARRIER.FLEXIBLE DUCT SHALL MEET NFPA 90A �� ®' C-4 WITH FLAME SPREAD UNDER 25,SMOKE DEVELOPED UNDER 50,AND SHALL BE RATED FOR MINIMUM 2"W.G. TESTING AND BALANCING:TEST AND ADJUST ALL MECHANICAL SYSTEMS AND EQUIPMENT TO ASSURE PROPER 4444 14qz► PRESSURE AND 0 TO 250OF TEMPERATURE. PROVIDE SCREW-OPERATED METAL ADJUSTABLE CLAMPING DEVICES. BALANCE AND OPERATION. PERFORM TESTS IN ACCORDANCE WITH THE MOST CURRENT NEBB OR AABC,AND USE TWIST-LOCK TAP COLLARS AT CONNECTIONS INTO SHEETMETAL DUCTWORK.MAXIMUM EXTENDED LENGTH OF ASHRAE STANDARDS. ELIMINATE OBJECTIONABLE NOISE AND VIBRATION,AND ASSURE PROPER FUNCTION OF ® A -3 Cm FLEXIBLE DUCT SHALL NOT EXCEED 5 FEET. CONTROLS. BALANCING CONTRACTOR SHALL BE AN INDEPENDENT CERTIFIED TEST AND BALANCE CONTRACTOR, o WITH NEBB OR AABC SUBMIT COMPLETED AND CERTIFIED TEST AND BALANCE REPORT CERTIFICATION. BALANCE �� Q� • ALL SYSTEMS TO WITHIN 5%OF AIR FLOWS TO OWNER'S REPRESENTATIVE. INDICATED ON THE DRAWINGS,AND EXPOSED DUCTWORK: EXPOSED DUCTWORK SHALL BE CLEANED OF DEBRIS AND OIL,THEN WIPED DOWN WITH REPORT ALL DISCREPANCIES TO HVAC INSTALLER FOR CORRECTION.MARK FINAL BALANCE POSITIONS ON VINEGAR OR OTHER SURFACE PREPARING CHEMICAL TO PREPARE DUCT FOR PAINT PER ARCHITECT'S DIRECTION. DAMPERS WITH PERMANENT MARKER. DUCT SEALANT: PROVIDE POLYMERIC RUBBER TYPE SEALANT FOR USE ON BOTH INTERIOR LOCATED DUCTWORK HYDRONIC PIPING:PROVIDE SCHEDULE 40 STEEL PIPE WITH WELDED FITTINGS,OR TYPE"L"COPPER PIPE WITH AND DUCTWORK EXPOSED TO OUTDOOR CONDITIONS.SEALER SHALL HAVE HIGH BONDING STRENGTH FOR SURE, BRAZED JOINTS. PROVIDE DIELECTRIC SEPARATION FROM DISSIMILAR METALS. FIRST TIME SEALING OF JOINTS IN LOW, MEDIUM,AND HIGH PRESSURE DUCT SYSTEMS.SEALER SHALL BE HIGH IN SOLID CONTENT. PROVIDE A TWO PART TAPE SEALING SYSTEM, CONSISTING OF WOVEN FIBER TAPE IMPREGNATED PIPE INSULATION: PROVIDE RIGID, ONE-PIECE FIBERGLASS PIPE INSULATION,COMPLYING WITH REQUIREMENTS OF WITH A GYPSUM MINERAL COMPOUND,AND A MODIFIED ACRYLIC/SILICONE ACTIVATOR THAT REACTS ASTM C-547;WITH A FACTORY APPLIED WHITE KRAFT BONDED TO ALUMINUM FOIL, REINFORCED WITH FIBERGLASS EXOTHERMICALLY WITH THE TAPE.TWO PART TAPE SEALING SYSTEM MUST BE RATED FOR BOTH INDOOR AND YARN VAPOR JACKET WITH SELF-SEALING ADHESIVE LAP LONGITUDINAL JOINTS AND BUTT STRIPS FOR TRANSVERSE OUTDOOR APPLICATION.TAPE SHALL NOT CONTAIN ASBESTOS. JOINTS.JACKETING SHALL CONFORM TO ASTM C-1136,TYPE I,AND SHALL HAVE A MAXIMUM VAPOR TRANSMISSION RATING OF 0.02 PERM WHEN TESTED ACCORDING TO ASTM E 96, PROCEDURE A. INSULATION AND JACKET SHALL BE RATED FOR OPERATING TEMPERATURES UP TO 850°F.***INDICATE THICKNESS HERE ALONG WITH K-VALUE.***MAINTAIN CONTINUOUS VAPOR BARRIER ON CHILLED WATER PIPING. LOAD CALCULATION 6 MECH . NOTES 1 NTS NTS 05-02-13 ISSUE FOR LANDLORD & PERMIT 3/8"0 x LENGTH AS REQUIRED STEEL BOTTOM CORD OF STEEL JOIST 04-19-13 PRELIM PACKAGE ISSUE 2"WIDE MIN. DUCT BOLT WITH TWO OVERSIZED STEEL (WHERE APPLICABLE) STRAP 48"O.C.MAX. WASHERS AND LOCKING NUT 8"0 x 1 1 2"LONG EXPANSION � DATE REVISIONS 3 I / 502OCC ROUND DAMPER OR RIGID ROUND METAL DUCT BOLT INTO CONCRETE DECK KEY PLAN' EXTERNALLY INSULATED CONCRETE DECK (WHERE P830ACC RECTANGULAR RIGID DUCTWORK RIGID DUCTWORK TRANSIOPPOSED BLADE DAMPER APPLICABLE) �6 isyyia69�yy�011 1 FLEXIBLE DUCTWORK RIGID ROUND DUCT ELBOW Mg, EXPANSION SHIELD EXTERNALLY INSULATED TRANSITION AS REQUIRED � s; , .. :� ¢ v .' _`� y,�i,/�.>/�,,y �. k�,'/ ,,s.!.�.,syr o.;, IJrs/'' Y k y .:✓si: • INSULATED FLEXIBLE DUCT HANGER ROD1/2" �' �. r 3/kms ! yP s 3Yf ydk 1 x 16 GAGE x LENGTH AS REQUIRED CONTINUOUS MAX.LENGTH 4'4'. •.,....f, 't:••• � FLEXIBLE CASING AND ���1�• WIRE 50'-0"MAXIMUM GALV.SHEET METAL s � ( ) HANGER STRAP (TYP.) t , "'JLy SPIN -IN FITTING WITH I >&z s,„ } .'.:.,. . BALANCING DAMPER AND LOAD RATED FASTENERS 9' 71 45 DEG. EXTRACTORyy; RACK 8�PINION OPERATOR VOLUME DAMPER (FOR METAL SUPPLY DUCT NEWS (DAMPER USED FORE yyL�¢ i •s G,S£! z` q:£::E v' / .:=r".J. >'./ s C",,.. '#s..s..l.: � h' r : FINAL BALANCE s BALANCING) CING) ADJUSTMENT) ROUND DUCTWORK DIE CAST MOUNTING CUP F7 It HANGER STRAP L'OCCITANE DIFFUSER TRIM FRAME DIFFUSER CEILING SPACE #H6 3"0 COVER PLATE LOCATION: SOCKET WRENCH LINEAR SLOT DIFFUSER WITH PLENUM BOX CONCEALED REGULATOR KIT L' OCCITAN STRAPPINGDETAIL 2SUPPLY DUCT DETAIL 4 TYPICAL DUCT EN PROVENCE NTS NTS BOUTIQUE #057 WASHINGTON SQUARE MALL SPACE #H6 9585 SW WASHINGTON SQ. RD. TIGARD, OR 97223 2Y2'MTL.STUDS 16"O.C.TO USG CEILING SYSTEM 12 GA GALVANIZED STEEL WIRE STRUCTURE ABOVE AREA: 621 SF 270�30 1 BOWDEN CABLE BRACE AS REQUIRED FIRE PROOF&FIRE SEAL ALL / PENETRATIONS SHEET TITLE: 12 GA GALVANIZED PLENUM BOX AND SUPPORT CONTROL SYSTEM STEEL WIRE SYSTEM, REFER TO MEP DWGS. MECH , DETAILS PLENUM BOX AND SUPPORT DEMISING WALL,G.C.SHALL _!-___--- ------------.._.__.--.------..-...._.................... ..... ................. NOTE: SCALE: N.T.S. SYSTEM, REFER TO MEP DWGS. VERIFY THAT ALL EXISTING _--_ -..-. :. 12'-0"A.F.F. & SPECS . / DEMISING WALLS ARE 1 HR RATED T.O. LIGHT SOFFIT 1) COORDINATE EXACT LOCATION OF CEILING MOUNTED CONCEALED REGULATOR WITH ARCHITECT 18"MTL.STUDS 16"O.C. USG CEILING SYSTEM IF NOT G.C.SHALL UPGRADE PRIOR TO INSTALLATION. 2) THE 270-301 BOWDEN CABLE CONTROL SYSTEM IS DESIGNED TO BE IMBEDDED IN THE CEILING FLUSH REFER TO SCHEDULE FOR PROJECT NO. 13-1802 WITH THE FINISHED SURFACE. PARTITION TYPE / _ TOP OF SOFFIT MNTD.CONTINUOUS 3) CABLE SHALL CONSIST OF BOWDEN CABLE 0.054 STAINLESS STEEL CONTROL WIRE ENCAPSULATED IN �. 12'-0"A.F.F. TRACK WITH LIGHT FIXTURE -- — 1 1'-0"A.F.F. 1/16"FLEXIBLE GALVANIZED SPIRAL WIRE SHEATH. 4"SUPPLY AIR DIFFUSER, T.O. LIGHTING SOFFIT SEE RCP 8�ELECTRICAL DRAWINGS ' SCALE: 1/4" = 1 —0" REFER TO MEP DWGS. B.O.CEILING @ FRAGRANCE 4) LOCKING RACK AND PINION GEAR DRIVE SHALL BE CONSTRUCTED OF 14 GAUGE STEEL AND SHALL BE FOR TYPE&LOCATION. REFER TO USED TO CONVERT ROTARY MOTION INTO PUSH-PULL MOTION. COVE MNTD. LIGHT FIXTURE PROVIDE BLOCKING&POWER FEED 6"SUPPLY AIR DIFFUSER, DATE: 04/17/13 SEE RCP&ELECTRICAL MEP DWGS. 5) CONTROL SHAFT SHALL BE"D"-STYLE FLATTENED 1/4"DIAMETER WITH 2650 ROTATION PROVIDING 1-1/2" DRAWINGS FOR TYPE& 1. . A.F.F. _ AS REQUIRED (TYP). ' B.00.CEILING @SKINCARE LINEAR TRAVEL CAPABILITY. LOCATION. PROVIDE VVTy DRAWN BY: KJ BLOCKING&POWER FEED LINE OF WALL BEYOND AS REQUIRED (TYP). REVIEWED BY: BB SHEET NO. YOUNG REGULATOR DETAIL 5 DIFFUSER FOR COVE & WALLS 3 NTS NTS I I DIVISION 15010 - GENERAL REQUIREMENTS 5.3 REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUND 8.5 ALL ELECTRICAL DEVICES, WIRING, CONDUIT, ETC., RELATED TO DEMOLISHED 3.7 SANITARY AND VENT MATERIAL SHALL BE AS FOLLOWS: 2.2 INSTALL COMPLETE AND PLACE IN PROPER OPERATION PER MANUFACTURER'S DEFECTIVE DURING THE WARRANTY PERIOD. IN THE CASE OF REPLACEMENT OR EQUIPMENT/SYSTEMS SHALL BE REMOVED. WIRING SHALL BE DISCONNECTED AT CIRCUIT RECOMMENDATIONS, LUBRICATE AND ADJUST AS REQUIRED. FURNISH AND INSTALL -- 1.0 GENERAL PAIR DUE TO FAILURE WITHIN THE WARRANTY PERIOD.THE WARRANTY ON THAT PORTION BREAKERS, REMOVED AND"SPARE" BREAKERS MARKED 3.7a BELOW GRADE STORM AND SANITARY INSIDE BUILDING. CLEAN SET OF FILTERS PRIOR TO BALANCING. ken neth P ark OF THE WORK SHALL BE EXTENDED FOR A MINIMUM PERIOD OF ONE (1) YEAR FROM THE 3.7al SERVICE WEIGHT-CAST IRON PIPE ASTM A-74-82 WITH ASTM C-564-70 NEOPRENE 1.1 SPECIFICATIONS ARE APPLICABLE TO ALL CONTRACTORS AND/OR CONTRACTORS DATE OF SUCH REPLACEMENT OR REPAIR. 8.6 MECHANICAL CONTRACTOR SHALL REMOVE AND RECLAIM ANY REFRIGERANT IN COMPRESSION JOINTS OR NO HUB WITH CLAMPS. 2.3 EQUIPMENT TO BE MAKE AND MODEL AS SCHEDULED UNLESS ALTERNATE EXISTING SYSTEMS PRIOR TO DEMOLITION OF ANY EQUIPMENT ACCORDING TO FEDERAL 3.7a2 PVC-DMV PLASTIC ASTM D-1785 WITH ASTM D-2665 DMV SOLVENT WELD EQUIPMENT OF EQUIVALENT QUALITY AND PERFORMANCE IS SUBMITTED AS A SUBSTATION FOR MECHANICAL SYSTEMS. REQUIREMENTS. SOCKET FITTINGS. PRIOR TO BIDDING.ALL SUBSTITUTIONS ARE SUBJECT TO ACCEPTANCE WITHOUT Architecture DIVISION 15050 BASIC MATERIALS AND METHODS QUALIFICATION BY OWNER, ENGINEER AND ARCHITECT. Urban Planning 1.2 CHECK OTHER PLANS AND SPECIFICATIONS AND FULLY COORDINATE WITH OTHER 8.7 ALL ASBESTOS REMOVAL WILL BE HANDLED BY THE OWNER AND IS NOT A PART OF 3.7b ABOVE GRADE SANITARY/STORM SEWER AND VENT MATERIAL SHALL BE AS Store Design TRADES, OWNER AND ARCHITECT REQUIREMENTS. - Mixed-Use 360 Lexington Avenue 1.0 GENERAL THIS WORK. FOLLOWS: 2.4 CONTRACTOR SHALL PERFORM ROUTINE SERVICE INSPECTION OF ALL EXISTING New York,NY10017 1.3 CONFORM TO ALL GENERAL AND SPECIAL CONDITIONS OF CONTRACTS 3.7bl NO-HUB CAST IRON PIPE CISPI 1-301-78. HVAC EQUIPMENT TO REMAIN. LUBRICATE BEARINGS, SERVICE CONTROL SYSTEMS, Retail Development www.kennethpark.com SPECIFIED BY ARCHITECT AND/OR OWNER. 1.1 PROVIDE ALL MATERIALS, LABOR, EQUIPMENT,AND ACCESSORIES REQUIRED TO 8.8 EXAMINE AREAS AND CONDITIONS UNDER WHICH DEMOLITION WORK MUST BE 3.7b2 SCH.40 GALVANIZED STEEL PIPE ASTM A-120-83 WITH CAST IRON SCREWED FITTINGS REPLACE FAN BELTS AND INSTALL NEW FILTERS IN EACH ROOFTOP UNIT. FURNISH AND INSTALL THE MECHANICAL ITEMS IDENTIFIED IN THIS SECTION. PERFORMED.THIS CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES ANSI B-16.22 1983. 1.4 VISIT SITE CHECK FACILITIES AND CONDITIONS AND MAKE ALL NECESSARY PERFORMING DEMOLITION WORK AND/OR DEMOLITION WORK PERFORMED BY THE 2.5 CONTRACTOR SHALL FIELD VERIFY REFRIGERANT CHARGE AND ADD REFRIGERANT IF MEP Consultant OBSERVATIONS AND MEASUREMENTS. NOTE CONDITIONS UNDER WHICH WORK IS TO BE 1.2 THIS SECTION INCLUDES BASIC MECHANICAL MATERIALS AND METHODS TO OWNER. 4.0 DOMESTIC WATER PIPING THE CHARGE IS LESS THAN MANUFACTURER'S SPECIFICATIONS PERFORMED AND TAKE ALL ITEMS INTO CONSIDERATION IN BID. COMPLEMENT OTHER DIVISION 15 SECTIONS IN THIS SPECIFICATION AND REQUIREMENTS INDICATED ON THE MECHANICAL DRAWINGS. 8.9 REMOVE ALL SUPPORTS, HANGERS, ETC., RELATED TO EQUIPMENT AND MATERIAL 4.1 INSTALL DOMESTIC WATER PIPING AS INDICATED ON DRAWINGS. INCLUDE ALL 2.6 SUBMIT SERVICE REPORT TO TENANT INDICATING CONDITION OF UNIT AND REPORT Ah INDICATED TO BE DEMOLISHED. FITTINGS,VALVES, HANGERS,AND OTHER ACESSORIES INCLUDING WATER METER AND ANY MAJOR COMPONENT FAILURES OR MALFUNCTIONS. REPORT SHALL INCLUDE COST 1.5 SYSTEMS ARE TO BE COMPLETE AND WORKABLE IN ALL RESPECTS, PLACED IN L INCLUDE OPERATION AND PROPERLY ADJUSTED. 2.0 SUPPORTS AND HANGERS BACKFLOW 8.10 WHERE TEMPERATURE CONTROLS ARE INDICATED FOR DEMOLITION,RETAIN THE EQUIPMENT REQUIRED RFOR TCOMPL EEND E INSTALLATION.STIC WATER PING TO ALL FIXTURES AND PARTS ANDTO LABOR,ALL AEQUIPMENT IS AL BE PLACED IN FULL NG OR DAMAGED ITEMS LOPERATION WITH ISTED. COST LCONTROLS 1.6 EACH CONTRACTOR SHALL PROVIDE FOR HIS OWN CLEANUP, REMOVAL AND 2.1 HANGERS AND SUPPORTS ARE TO BE PROVIDED TO PROPERLY SUPPORT,SECURE SERVICES OF A TEMPERATURE CONTROL CONTRACTOR TO PERFORM SUCH DEMOLITION. CALIBRATED UPON COMPLETION OF PROJECT. don penn a consulting engineer AND ALIGN PIPING AND TO MEET FIELD CONDITIONS AND AS MANUFACTURED BY 4.2 INCLUDE UNIONS, OR OTHER DISCONNECT MEANS,STOPS OR VALVES FOR 635 Westport Parkway LEGAL DISPOSAL OF ALL RUBBISH DAILY. GRINNELL OR MICHIGAN. DIVISION 15100 - INSULATION ISOLATION OF FIXTURES AND EQUIPMENT.VALVES TO BE FULLY COMPATIBLE WITH PIPING 3.0 COOLING COIL CONDENSATE DRAINS Suite 300 FOR SERVICE INTENDED AS MANUFACTURED BY NIBCO CRANE OR MILWAUKEE. INCLUDE Grapevine,Texas 76051 1.7 CONTRACTOR SHALL PROTECT HIS WORK,THE EXISTING AND ADJACENT PROPERTY Phone:817-410-2858 AGAINST WEATHER. 2.2 SPACING TO COMPLY WITH ASHRAE STANDARDS AND LOCAL CODE HOSE OR DRAIN VALVES AT LOW POINTS WHERE FIXTURES CANNOT BE USED FOR 3.1 PROVIDE EACH ROOFTOP UNIT WITH A FOUR (4) INCH DEEP TRAPPED CONDENSATE Fax:817-251-8411 REQUIREMENTS. 1.0 GENERAL DRAINAGE. DRAIN WITH CLEANOUT OF SCHEDULE 40 PVC.TERMINATE OVER CONCRETE SPLASH 1.8 CONTRACTOR SHALL PROTECT HIS WORK MATERIALS APPARATUS AND FIXTURES30 BLOCK ON ROOF ORAS REQUIRED PER LOCAL CODE. ESCUTCHEONS 1_1 FURNISH ALL MATERIAL, LABOR AND EQUIPMENT AS REQUIRED TO INSTALL 4.3 INSTALL SHOCK ABSORBERS AT EACH QUICK CLOSING FIXTURE AND WHERE SEAL: . FROM DAMAGE.ANY WORK DAMAGED BY FAILURE TO PROVIDE PROTECTION REQUIRED, COMPLETE PLUMBING AND HVAC INSULATION AS INDICATED ON MECHANICAL REQUIRED TO PREVENT WATER HAMMER AS MANUFACTURED BY J.R.SMITH SIOUX CHIEF 4.0 EQUIPMENT SCHEDULES SHALL BE REMOVED AND RELEASED WITH NEW MATERIAL AT THE CONTRACTORS EXPENSE. 3.1 FIT ALL PIPE PASSING THROUGH WALLS, FLOORS OR CEILINGS IN FINISHED ROOMS DRAWINGS AND IN THESE SPECIFICATIONS. OF ZURN. 1.9 CONTRACTOR MUST CONFIRM ALL UTILITY COMPANY REQUIREMENTS AND WITH STEEL OR BRASS ESCUTCHEONS.WHERE SURFACE IS TO RECEIVE A PAINT FINISH MAKE 4.1 SEE EQUIPMENT SCHEDULES ON MECHANICAL DRAWINGS. ESCUTCHEONS PRIME PAINTED; OTHERWISE MAKE ESCUTCHEONS NICKEL OR CHROME 1.2 INSTALL IN FULL ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 4.4 HANGERS ON INSULATED PIPE TO BE OUTSIDE OF INSULATION,SIZED ACCORDINGLY - CONNECTIONS POINTS IN FIELD PRIOR TO STARTING WORK. PLATED.WHERE PIPING IS INSULATED, FIT ESCUTCHEONS OUTSIDE INSULATION. AND WITH A SUFFICIENT SADDLE TO PROTECT INSULATION AS MANUFACTURED BY L 1 2.0 PLUMBING INSULATION GRINNELL OR MICHIGAN. 1.10 ARRANGE FOR AND OBTAIN OWNER'S AND INSURANCE REPRESENTATIVE'S 4.0 PIPE IDENTIFICATION PERMISSION FOR ANY SERVICE SHUTDOWNS. 2.1 INSULATE ALL ABOVE GRADE HOT AND COLD WATER PIPING WITH MOLDED 4.5 DOMESTIC WATER PIPING SHALL BE AS FOLLOWS: - 4.1 IDENTIFY EACH PIPE,VALVE IN EQUIPMENT ROOMS,ABOVE ACCESSIBLE CEILINGS FIBERGLASS HAVING AN ALL SERVICE JACKET. DIVISION 15500 AIR DISTRIBUTION SYSTEMS 1.11 THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR - CONSTRUCTION MEANS, METHODS,SEQUENCES OF CONSTRUCTION AND THE SAFETY OF AND IN ACCESSIBLE SHAFTS. 4.5a ABOVE GRADE-TYPR"L"HARD COPPER ASTM B 88-832 WITH WROUGHT ``•' ��' CL z �,, �� � 2.1 a INSULATION THICKNESS SCHEDULE: COPPER FITTINGS ASTM B 16.22 1980 AND NON-LEAD OR ANTIMONY SOLDER JOINTS. �� 0 WORKMEN. 2.1al LESS THAN 1-1/2" DIAMETER PIPE:3/4"THICK 1.0 GENERAL Q- o 2 M 4.2 COLOR CODE IDENTIFICATION BANDS OR MARKER BACKGROUNDS TO IDENTIFY w C CONTENTS OF PIPE AND DIRECTION OF FLOW LOCATED NEAR EACH VALVE AND FITTING 2.1a2 1-12"DIAMETER PIPE: I"THICK 4.5b BELOW GRADE-TYPE"K"SOFT COPPER WITHOUT JOINTS. 1.1 FURNISH ALL MATERIALS LABOR EQUIPMENT AND ACCESSORIES REQUIRED TO °� © LU U 1.12 NO PIPING, DUCTWORK, WIRING, ETC..SHALL BE INSTALLED OR ROUTED ABOVE ON BOTH SIDES OF PIPE PASSING THROUGH WALLS AND ON LONG RUNS AT NOT OVER 20 INSTALL COMPLETE AIR DISTRIBUTION SYSTEMS. ELECTRICAL PANELS AND EQUIPMENT OR THROUGH ELEVATOR EQUIPMENT ROOMS. FOOT INTERVALS. 2`2 INCLUDE INSULATION OF FITTINGS AND VALVES. KEEP VAPOR BARRIERS INTACT. 4.6 FLUSH, VENT AND SANITIZE ALL WATER PIPING WITH CHLORINE AS REQUIRED PER APPLY TO MANUFACTURER'S RECOMMENDATIONS. AWWA, LOCAL BUILDING DEPARTMENT AND HEALTH DEPARTMENT CODES. 1.2 CONTRACTORS BIDDING THIS PROJECT SHALL VISIT THIS SITE AND FAMILIARIZE 1.13 THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL 5.0 ROOF CURBS THEMSELVES WITH ALL CONDITIONS AFFECTING THEIR WORK.SUBMISSION OF A BID ON CONTRACTOR AND OBTAIN A WRITTEN APPROVAL IDENTIFYING THE ELECTRICAL 2.3 HANDICAPPED LAVATORY INSULATION -INSULATE ALL EXPOSED WASTE AND WATER 4.7 DOMESTIC HOT AND COLD WATER PIPING UNDER CONCRETE FLOOR TO BE THIS PROJECT SHALL BE CONSTRUED AS HAVING SUCH KNOWLEDGE. CHARACTERISTICS OF ALL MECHANICAL EQUIPMENT PRIOR TO ORDERING OF 5.1 CURB SHALL BE 18 GAUGE GALVANIZED STEEL WITH CONTINUOUS WELDED SEAMS, SUPPLY PIPING UNDER LAVATORY WITH SAFETY COVERS PER ADA REQUIREMENTS AS COVERED WITH SAND SO THAT PIPING WILL NOT BECOME EMBEDDED IN THE FLOOR EQUIPMENT. NO ADDITIONAL PAYMENT WILL BE MADE FOR LACK OF CONTRACTOR WOOD NAILER, COUNTER FLASHING AND INSULATION.TOP OF CURB SHALL BE A MINIMUMMANUFACTURED BY PLUMBEREX SPECIALTY PRODUCTS, MCGUIRE OR TRUEBRO. SLAB. 1.3 VERIFY EXACT CONDITIONS IN FIELD AND COORDINATE WITH THESE DRAWINGS AND COORDINATION OF ELECTRICAL CHARACTERISTICS. OF 12"ABOVE THE FINISHED ROOF SURFACE. OTHER TRADES BEFORE BEGINNING NEW WORK. 2.4 REPAIR SECTIONS OF EXISTING PIPING INSULATION DAMAGED OR DAMAGED 4.8 ALL PIPING UNDER CONCRETE FLOOR SHALL BE TYPE"K"SOFT COPPER 1.14 DURING CONSTRUCTION THE CONTRACTOR MAY UNCOVER AN EXISTING 1.4 DETERMINE EXACT LOCATIONS FOR ALL NEW AND RELOCATED DUCTWORK AND DURING THIS CONSTRUCTION PERIOD. USE INSULATION OF SAME THICKNESS AS EXISTING CONDITION THAT WILL HAVE TO BE MODIFIED.ANY SUCH WORK WHICH COMES UNDER 5.2 PROVIDE CURB FOR ALL ROOF PENETRATIONS OF DUCTS AND PIPING. CONTINUOUS. NO SPLICES OR FITTINGS WILL BE ALLOWED. ACCESSORIES FIELD. INSULATION, INSTALL NEW JACKET LAPPING AND SEALED OVER EXISTING. THE JURISDICTION OF THIS CONTRACTOR SHALL BE DONE BY THE CONTRACTOR WITHOUT 5.3 ALL CUTTING AND PATCHING OF EXISTING ROOF SHALL BE BY THE OWNER'S 4.9 EXTREME CAUTION MUST BE TAKEN SO THAT NO COPPER PIPING AND INSULATION 1.5 COORDINATE WORK OF THIS CONTRACT WITH OTHER TRADES. EXTRA COST TO THE OWNER,AS THOUGH FULLY DETAILED PLANS AND/OR DESCRIBED IN ROOFING CONTRACTOR AND PAID FOR BY THE MECHANICAL CONTRACTOR. 3.0 HVAC INSULATION UNDER CONCRETE FLOOR BECOMES CRUSHED, CUT,SPLIT OR DEFORMED DURING THE - THE SPECIFICATIONS. POURING OF THE FLOOR SLAB. 1.6 ANY DISCREPANCIES BETWEEN WHAT IS SHOWN ON DRAWINGS OR SPECIFIED AND 6.0 FIRESTOPPING 3_1 INSULATE ALL SUPPLY, RETURN,AND EXHAUST DUCTS WITH 1-1/2"THICK FOIL FACED THE ACTUAL CONDITIONS IN THE FIELD SHALL IMMEDIATELY BE BROUGHT TO THE 1.15 WORK RELATED TO THE EXISTING BUILDING SHALL BE COORDINATED TO MINIMIZE REINFORCED KRAFT JACKET, FIBERGLASS DUCT WRAP FULLY SECURED TO DUCT. LAP AND 5.0 FIRE PROTECTION PIPING ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. INTERFERENCE OR INTERRUPTION OF NORMAL BUILDING USE BY OWNER. REFER TO 6.1 ALL ROOF OPENINGS THROUGH FIRE RATED WALLS FLOORS AND/OR ROOFS FOR TAPE SEAMS AND SECURE TIGHTLY TO THE DUCTS WITH WIRE OR STICK PINS. ARCHITECTURAL PLANS FOR PHASING REQUIREMENTS. - 1.7 BUILDING AND SURFACE DAMAGED DURING INSTALLATION SHALL BE REPAIRED, DUCTWORK; PIPING , ETC.,SHALL BE FIRE SEALED WITH CALCIUM SILICATE,SILICONE "RTV" 3.2 ALL INSULATION TO BE APPLIED IN FULL ACCORDANCE WITH THE 5.1 SEE SECTION 15300, FIRE PROTECTION SYSTEMS. REPLACED,AND/OR RESTORED TO ORIGINAL CONDITION AFTER COMPLETION OF WORK 2.0 CODES, PERMITS,STANDARDS,AND REGULATIONS FOAM, 3M FIRE RATED SEALANTS, HILTI FIRESTOP SYSTEMS, OR APPROVED EQUAL TO - MAINTAIN THE INTENDED FIRE RATING AND ASSOCIATED 'UL' RATINGS MANUFACTURER'S RECOMMENDATIONS AND COMPLY WITH 25/50 FLAME AND SMOKE 6.0 FIRESTOPPING AND BEFORE ACCEPTANCE BY OWNER. HAZARD RATINGS PER ASTM E-84, NFPA 255 ABD UL 723. 1.8 PROVIDE ACCESS PANELS AT ALL GYPSUM BOARD CEILING WHERE 2_1 CONFORM TO APPLICABLE CODES (LOCAL, STATE, NATIONAL CODES, 7.0 CUTTING, PATCHING AND DRILLING 6.1 SEE SECTION 15050, BASIC MATERIALS AND METHODS. NFPA, OSHA, ETC.) GOVERNMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS,AND 3.3 INSULATE REFRIGERANT SUCTION LINE WITH 1/2 ELASTOMERIC FOAM INSULATION - MECHANICAL OR PLUMBING ARE CONCEALED ABOVE. APPLICABLE STANDARDS. 7.1 ALL CUTTING AND PATCHING OF THE BUILDING CONSTRUCTION REQUIRED FOR THIS WITH JOINTS AND SEAMS SEALED VAPOR TIGHT. DIVISION 15500 - HEAT GENERATION EQUIPMENT 2.0 DUCTWORK 2.2 OBTAIN PERMITS AND PAY ALL FEES.ARRANGE FOR ALL REQUIRED WORK SHALL BE BY THIS CONTRACTOR UNLESS SHOWN ON ARCHITECTURAL DRAWINGS AND CONFIRMED AS TO SIZE AND LOCATION PRIOR TO NEW CONSTRUCTION. CUTTING 3_4 INSULATE AIR CONDITIONING CONDENSATE DRAIN PIPING WITH 1/2" THICK 2.1 FABRICATE AND ERECT ALL DUCTWORK TO ASHRAE AND SMACNA OS-O2-13 ISSUE FOR LANDLORD & PERMIT INSPECTIONS AND APPROVALS. SHALL BE IN A NEAT AND WORKMANLIKE MANNER. MOLDED FIBERGLASS INSULATION. 1.0 GENERAL STANDARDS FROM NO. 1 GALVANIZED STEEL. COMPLY WITH NFPA 90A REQUIREMENTS. 3.5 PROVIDE REMOVABLE INSULATION SECTION TO COVER PARTS OF EQUIPMENT _ EQUIPMENT AND ACCESSORIES AS REQUIRED TO 04-19-13 PRELIM PACKAGE ISSUE. - 3.0 DRAWINGS WHICH MUST BE OPENED PERIODICALLY FOR MAINTENANCE. INCLUDE METAL VESSEL 1.1 FURNISH ALL MATERIAL, LABOR, 2.2 DUCTWORK SHALL BE SMACNA LOW PRESSURE CONSTRUCTION 2" STATIC 7.2 NEATLY SAW CUT ALL RECTANGULAR OPENINGS,SET SLEEVE THROUGH OPENING, DRAWINGS.L NICDRGS. H N ME EQUIPMENT AS INDICATED L EOMECHANICAL INSTALL AND FINISH PATCH OR PROVIDE TRIM FLANGE AROUND OPENING. COVERS, FASTENERS, FLANGES, CHILLED WATER PUMPS, FRAMES AND ACCESSORIES. IPRESSURE RATING WITH SEAL CLASS B SEAMS AND JOINTS. 3.1 THE SYSTEMS AS SHOWN ON MECHANICAL DRAWINGS ARE � DATE REVISIONS v DIAGRAMMATIC, CONFORM TO ALL DIMENSIONS BY FIELD MEASUREMENTS 1.2 INSTALL IN FULL ACCORDANCE WITH LOCAL CODE REQUIREMENTS OTHER 7.3 NEATLY SAW CUT FLOORS AND PATCH FLOOR TO MATCH EXISTING, 3.6 REPAIR DAMAGED SECTIONS OF EXISTING MECHANICAL INSULATION DAMAGED 2.3 INCLUDE ALL ACOUSTIC,AIRFOIL SHAPED PERFORATED ALUMINUM TURNING VANES, DURING THIS CONSTRUCTION PERIOD. USE INSULATION OF SAME THICKNESS AS EXISTING SPECIFICATION SECTION REQUIREMENTS,AND MANUFACTURER RECOMMENDATIONS. MANUAL DAMPERS, FLEXIBLE CONNECTORS, GRILLES AND DIFFUSERS,ACOUSTIC LINING, INCLUDING FLOOR COVERING. KEY PLAN: 3.2 THE EXACT LOCATIONS FOR FIXTURES, EQUIPMENT AND PIPING WHICH IS NOT INSULATION, INSTALL NEW JACKET LAPPING AND SEAL OVER EXISTING. AND OTHER SHEET METAL ACCESSORIES FOR THE PROJECT. r , y , ; 2.0 EQUIPMENT SCHEDULES 'y y q; ECr ertsy;: say £ y � siexi ✓y�.r i 'F ;s . COVERED IN BY DRAWINGS.SHALL BE OBTAINED FROM THE ARCHITECT OR HIS ft� u %�,,y . 7.4 CONTRACTOR SHALL FILE VERIFY SLAB-ON-GRADE OR SUPPORTED FLOOR 2.4 ALL BRANCH CONNECTION FITTINGS IN RECTANGULAR DUCTWORK SHALL BE 45 "' H=: REPRESENTATIVE IN THE FIELD AND THE WORK SHALL BE LAID OUT ACCORDINGLY. - � s,x,; 3.7 REPLACE DAMAGED INSULATION WHICH CANNOT BE REPAIRED SATISFACTORILY, 2.1 SEE EQUIPMENT SCHEDULES ON MECHANICAL DRAWINGS. s CONSTRUCTION TYPE PRIOR TO CUTTING. UNDER NO CIRCUMSTANCES SHALL THIS - - DEGREE TRANSITION TYPE, CONICAL FITTINGS OR SPIN-IN FITTINGS WITH INTEGRAL AIR INCLUDING UNITS WITH VAPOR BARRIER DAMAGE AND MOISTURE SATURATED UNITS. m �y ��,,� CONTRACTOR CUT A STRUCTURAL FLOOR SLAB, WHETHER ON GRADE OR SUPPORTED, SCOOPS. BUTT FITTINGS ARE NOT ACCEPTABLE. . 3.3 DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT ONE ANOTHER. ,, F WITHOUT PRIOR WRITTEN APPROVAL FROM THE ARCHITECT. IF FLOOR SLAB l �� ��.... ANY MATERIALS OR LABOR CALLED FOR IN ONE BUT NOT THE OTHER SHALL BE FURNISHEDINDICATED TO ' _ BE CUT ON MECHANICAL PLANS IS FOUND TO BE STRUCTURAL IN NATURE, DO NOT CUT. DIVISION 15500 REFRIGERATION EQUIPMENT 2.5 INSTALL TWO (2) INCH DEEP SECONDARY DRAIN PAN BELOW DOMESTIC WATER AS IF BOTH WERE MENTIONED IN THE SPECIFICATIONS AND SHOWN ON THE DRAWINGS. - ( I CONTACT ARCHITECT IMMEDIATELY FOR FURTHER DIRECTIONS. HEATERS. PIPE THREE_FOURTH (3/4) INCH DRAIN TO FLOOR DRAIN INDEPENDENTLY OF ALL , ys = OTHER DRAINS. 4.0 BASE EQUIPMENT, MATERIALS AND SUBSTITUTIONS 1.0 GENERAL 7.5 CORE DRILL AND SLEEVE ALL ROUND OPENINGS. E Ea 2.6 EXHAUST DUCT OUTLETS SHALL BE INSTALLED A MINIMUM OF 10'-0" FROM ALL 4.1 ALL EQUIPMENT AND MATERIALS SHALL BE NEW FREE OF DEFECTS AND U.L. 1_1 FURNISH ALL MATERIAL, LABOR, EQUIPMENT, AND ACCESSORIES AS REQUIRED TO n � Fy�� fyai 7.6 DO NOT CUT ANY STRUCTURAL COMPONENTS WITHOUT ARCHITECT'S IV N 1 - PIPING AND VALVES INSTALL EQUIPMENT AS INDICATED ON MECHANICAL DRAWINGS. OUTSIDE AIR INTAKES. �s �y NORD OM LABELED. WRITTEN APPROVAL, INCLUDING, BUT NOT LIMITED TO ROOF JOISTS, COLUMNS, FLOOR ®DIVISION 5 ®® 3.0 DUCT LINER JOIST, BEAMS, GIRDERS, STRUCTURAL FLOOR SLABS, TC. 1.2 INSTALL IN FULL ACCORDANCE WITH LOCAL CODE REQUIREMENTS, OTHER 4.2 BASE BID MANUFACTURERS ARE INCLUDED IN THE SPECIFICATIONS OR LISTED IN 1.0 GENERAL DAMAGED SCHEDULES ON THE DRAWINGS.ALL OTHER MANUFACTURERS ARE CONSIDERED A 7.7 PATCH AND FINISH TO MATCH ADJACENT AREA THAT HAVE BEEN CUT, SPECIFICATION SECTION REQUIREMENTS,AND MANUFACTURER RECOMMENDATIONS. 3.1 ACOUSTIC LINE ALL RECTANGULAR DUCTS INDICATED ON DRAWINGS WITH ONE (1) L'OCCITANE SUBSTITUTION. - 1.1 FURNISH ALL MATERIAL, LABOR, EQUIPMENT AND ACCESSORIES AS REQUIRED TO 2,0 EQUIPMENT SCHEDULES INCH THINK NON-FLAKING, COATED MEDIUM DENSITY LINER,APPLY TO MANUFACTURER'S SPACE #H6 OR MODIFIED ASA RESULT OF THE INSTALLATION OF THE MECHANICAL SYSTEMS. FIRE STOP INSTALL COMPLETE PLUMBING AND HVAC PIPING SYSTEMS AS INDICATED ON RECOMMENDATIONS. 4.3 THE NAME OR MAKE OF ANY ARTICLE, DEVICE, MATERIAL, FORM OF ALL PENETRATIONS OF FIRE RATED CONSTRUCTION IN A CODE APPROVED MANNER. MECHANICAL DRAWINGS AND IN THESE SPECIFICATIONS. 2.1 SEE EQUIPMENT SCHEDULES ON MECHANICAL DRAWINGS. LOCATION: CONSTRUCTION, FIXTURE, ETC.,STATED IN THIS SPECIFICATION, WHETHER OR NOT THE 3.2 DUCT DIMENSIONS INDICATED ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS (FREE WORDS"OR APPROVED EQUAL"ARE USED,SHALL BE KNOW AS"STANDARD." 7`8 ALL CONTRACTORS SHALL CONFIRM WITH OWNER, PRIOR TO BID,TIMES AVAILABLE 1 2 INSTALL IN FULL ACCORDANCE WITH LOCAL CODE REQUIREMENTS, OTHER AREA). WALLSFOR , TCISE P AS WELING L S TIMES OR WORK WHICH REQUIRES ACCESS N OORK SUCH AS CUTTING AND CORE DRILLING FADJOINING SPECIFICATION SECTION REQUIREMENTS AND MANUFACTURER'S RECOMMENDATIONS DIVISION 15700 - HVAC SYSTEMS AND EQUIPMENT 3.3 ALL RECTANGULAR DUCTWORK DOWNSTREAM OF FPVAV BOXES SHALL BE LINED 4_4 ALL PROPOSALS SHALL BE BASED ON STANDARDS SPECIFIED. TENANT SPACES, INCLUDE ANY PREMIUM TIME IN BID. WITH V COATED MEDIUM DENSITY LINER.APPLY TO MANUFACTURER'S L' OCCITAN 4.5 THE EQUIPMENT SCHEDULES ON THE DRAWINGS INDICATE MANUFACTURERS 7.9 EXACT LOCATION OF ROOF TOP AIR CONDITIONING UNITS SHALL BE APPROVED BY 2.0 CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS 1.0 GENERAL RECOMMENDATIONS. EN PROVENCE EQUIPMENT MODEL NUMBERS THAT THIS DESIGN HAS BEEN BASED ON.THE USE OF OTHER THE STRUCTURAL ENGINEER, MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL- PROVIDE VALVED WATER AND/OR GAS CONNECTION FOR EQUIPMENT FURNISHED 1 1 FURNISH ALL EQUIPMENT, MATERIALS, LABOR,TOOLS, ETC., FOR THE COMPLETE 3.4 DUCT LINER SHALL COMPLY WITH NFPA 90A AND 90B (LATEST EDITION) BOUTIQUE #057 MANUFACTURERS EQUIPMENT THAT IS LISTED AS ACCEPTABLE ALTERNATES THAT ENTAILS BY OTHER CONTRACTORS OR OWNER. REQUIREMENTS. GENERAL TRADES, STRUCTURAL, MECHANICAL, ELECTRICAL, ETC. REVISIONS ARE THE SUPPLEMENTAL SUPPORT STEEL FOR EQUIPMENT AND ROOF PENETRATIONS AFTER HVAC SYSTEM. INSTALL COMPLETE AND PLACE IN OPERATION. WASHINGTON SQUARE MALL APPROVAL OF STRUCTURAL ENGINEER CONTRACTOR'S RESPONSIBILITY.ANY ADDITIONAL COST OF SUCH CHANGES SHALL BE . 2.2 INCLUDE ACCESSORIES REQUIRED BY CODE, DRAWING OR MANUFACTURER'S 1.2 CONTRACTORS BIDDING THIS PROSECT SHALL VISIT THIS SITE AND FAMILIARIZE 4.0 DUCT ACCESSORIES SPACE #H6 PAID BY THE CONTRACTOR SUBMITTING THE ACCEPTABLE ALTERNATES WHICH INSTRUCTIONS. THEMSELVES WITH ALL CONDITIONS AFFECTING THEIR WORK.SUBMISSION OF A BID ON 7.10 THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL 4.1 FLEXIBLE DUCTWORK (AS MANUFACTURED BY CLEVAFLEX, FLEXMASTER OR 9585 SW WASHINGTON SQ. RD. NECESSITATES CHANGES IN INSTALLING SUCH SUBMITTED ALTERNATE EQUIPMENT, EVEN THIS PROJECT SHALL BE CONSTRUED AS HAVING SUCH KNOWLEDGE. TIGARD, OR 97223 THOUGH SUCH COST MAY BE A PART OF ANOTHER DIVISION OF WORK. CONTRACTOR PRIOR TO CONSTRUCTION.THE MECHANICAL CONTRACTOR SHALL 2.3 FULLY COORDINATE WITH KITCHEN EQUIPMENT AND LAUNDRY SUPPLIERS AND WIREMOLD).FLEXIBLE DUCTS SHALL BE INDEPENDENTLY SUPPORTED FROM THE STRUCTURE PROVIDE INFORMATION REGARDING OPENINGS IN WALLS, FLOORS, ETC.,CONCRETE CONFIRM ALL ROUGH-IN REQUIREMENTS PRIOR TO STARTING WORK. 1.3 VERIFY EXACT CONDITIONS IN FIELD AND COORDINATE WITH THESE DRAWINGS AND LIMITED CONNECTED WITH PLASTIC DRAW BANDS AND TIGHTENED. FLEXIBLE DUCTS SHALL BE 4.6 SUBSTITUTIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER. IF A SUBSTITUTION IS EQUIPMENT PADS AND FOUNDATIONS TO THE GENERAL CONTRACTOR. IF THE LIMITED TO 48"MAXIMUM STRAIGHT LENGTHS. FLEXIBLE DUCTS SHALL BE CONSTRUCTED OF MECHANICAL CONTRACTOR FAILS TO COMPLY WITH THIS REQUEST, OR IF INCORRECT OTHER TRADES BEFORE BEGINNING NEW WORK. 1-1/2"INSULATION WITH VINYL VAPOR BARRIER JACKET AND RATED AT 10 W.C. FOR SIZES AREA: 621 SF SUBMITTED, IT IS THE CONTRACTORS RESPONSIBILITY TO EVALUATE IT AND CERTIFY THAT THE INFORMATION IS GIVEN, THE NECESSARY CUTTING AND PATCHING WILL BE 3.0 SANITARY AND STORM SEWERS 1.4 DETERMINE EXACT LOCATIONS FOR ALL NEW AND RELOCATED EQUIPMENT, PIPING, THROUGH 12", U.L. LISTED,AND MEET 25/50 FLAME AND SMOKE TEST. FLEXIBLE DUCTS ARE SUBMISSION IS EQUIVALENT IN ALL RESPECTS TO THE BASE SPECIFICATIONS. PERFORMED BY THE GENERAL CONTRACTOR,AT THE MECHANICAL CONTRACTOR'S EXPENSECONDUITS AND DUCTWORK IN FIELD. NOT PERMITTED IN ROOMS WITHOUT CEILINGS. SHEET TITLE: . 3.1 INSTALL SANITARY AND STORM SEWERS,STACKS, VENTS, DRAINS, CLEANOUTS, ETC., 4.7 IF SUBSTITUTIONS ARE APPROVED, NOTIFY ALL OTHER CONTRACTORS, AS INDICATED ON THE DRAWINGS. 4.2 DAMPERS (AS MANUFACTURED BY RUSKIN, NAILOR OR SAFE-AIR) FABRICATE IN SUBCONTRACTORS, ETC., AFFECTED BY THE SUBSTITUTION AND FULLY COORDINATE WITH 1.5 COORDINATE WORK OF THIS CONTRACT WITH OTHER TRADES. CONFLICTS SHALL ACCORDANCE WITH SMACNA STANDARDS. PROVIDE END BEARINGS AND LOCKING MECHANICAL THEM.ANY COST RESULTING FROM SUBSTITUTION, WETHER BY THIS CONTRACTOR OR 8.0 DEMOLITION AND REMOVAL 3.2 SEWERS TO BE PITCHED A MINIMUM OF 1/4 PER FOOT FOR 3 SIZES AND UNDER AND RESOLUTIMMEDIAION BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.ARCHITECT'S INDICATING QUADRANT REGULATORS. BLADE TO BE SINGLE THICKNESS WITH CONTINUOUS �� �� RESOLUTION TO CONFLICTS SHALL BE FINAL. OTHERS,SHALL BE THE RESPONSIBILITY OF AND PAID FOR BY THE SUBSTITUTING CAP AND REMOVE ALL PIPING DUCTWORK AND EQUIPMENT 1/8"PER FOOT FOR 4"SIZES AND LARGER OR TO GRADES INDICATED ON PLANS. HINGE OR ROD. SPECIFICATIONS CONTRACTOR.APPROVED SHOP DRAWINGS DO NOT ABSOLVE THIS CONTRACTOR FROM 8=1 DISCONNECT, , INDICATED ON THE DRAWINGS OR AS REQUIRED FOR THE PROJECT. 1.6 ANY DISCREPANCIES BETWEEN WHAT IS SHOWN ON DRAWINGS OR SPECIFIED AND 4.3 CONTROL DAMPERS (AS MANUFACTURED BY RUSKIN, NAILOR OR SAFE-AIR) HIS RESPONSIBILITY. 3.3 CHANGES IN DIRECTION AND BRANCH CONNECTIONS SHALL BE MADE WITH THE ACTUAL CONDITIONS IN THE FIELD SHALL IMMEDIATELY BE BROUGHT TO THE FABRICATE BLADE OF DOUBLE THICKNESS SHEET METAL, OPPOSED BLADE TYPE WITH 8.2 ANY EQUIPMENT DESIGNATED 8Y OWNER TO BE SALVAGED SHALL BE PROTECTED APPROVED DRAINAGE FITTINGS COMPATIBLE WITH THE PIPING SYSTEM MATERIAL WHICH IS ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. SELF-ALIGNING ROD AND END BEARING SUITABLE FOR USE WITH AN ACTUATOR. 3_1802 . 4.8 ALL EQUIPMENT SHALL BE INSTALLED IN FULL ACCORDANCE WITH THE AND DELIVERED TO THE OWNER ON SITEINSTALLED. PROJECT N0. MANUFACTURER'S DATA AND INSTALLATION INSTRUCTIONS, IT IS THIS CONTRACTORS 1.7 BUILDING AND SURFACES DAMAGED DURING INSTALLATION SHALL BE REPAIRED, 4.4 BACKDRAFT DAMPERS (AS MANUFACTURED BY RUSKIN, NAILOR OR SAFE-AIR) RESPONSIBILITY TO CHECK AND CONFORM THESE REQUIREMENTS PRIOR TO STARTING 3.4 ALL FIXTURES AND SANITARY DRAINS SHALL BE VENTED AS INDICATED ON REPLACED AND/OR RESTORED TO ORIGINAL CONDITION AFTER COMPLETION OF WORK WORK. 8.3 DEMOLITION SHALL BE DONE IN A MANNER SO AS NOT TO DAMAGE ADJACENT DRAWINGS AND IN ACCORDANCE WITH CODE. AND BEFORE ACCEPTANCE BY OWNER. MULTIPLE BLADE, PARALLEL TYPE DAMPER CONSTRUCTED OF GALVANIZED STEEL WITH FELT SCALE: 1/4" = 1'-0" WORK AND NOT AFFECT THE OPERATION OF SYSTEMS TO REMAIN IN USE.ANY ITEM TO FO FLEXIBLE VINYL.SEALED EDGES, BALL BEARINGS, PIVOT PIN AND ADJUSTMENT DEVICE REMAIN THAT IS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED AND/OR REPAIRED 2.0 EQUIPMENT FOR VARYING PRESSURES. DATE: 04/17/13 ' 5.0 WARRANTY 3.5 VENTS ARE TO BE EXTENDED THROUGH ROOF AS INDICATED ON DRAWINGS AND AT THE CONTRACTOR'S EXPENSE. FLASHED WITH 4 LB. LEAD WITH VENT FLASHING TOP TURNED DOWN TWO (2) INCHES 4.5 FIRE DAMPERS (AS MANUFACTURED BY RUSKIN, NAILOR OR SAFE-AIR) FABRICATE IN 5.1 FULLY WARRANTY ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR ONE MINIMUM INSIDE PIPE 2_1 MECHANICAL CONTRACTOR TO FURNISH ALL HVAC EQUIPMENT INDICATED ACCORDANCE WITH NFPA 90A AND UL555. DAMPERS SHALL BE SUITABLE FOR USE IN THE DRAWN BY: KJ 1) YEAR FROM DATE OF ACCEPTANCE. 8.4 ALL OPEN ENDED PIPING AND DUCTWORK THAT IS TO REMAIN SHALL BE CAPPED AND/OR SCHEDULED ON THE DRAWINGS COMPLETE WITH BASES, ISOLATORS,SUPPORTS VERTICAL OR HORIZONTAL POSITION AS INDICATED ON THE DRAWINGS, BE TYPE'B'WITH ( AND PROPERLY SECURED. 3.6 PVC PIPING SHALL NOT BE INSTALLED UNLESS PERMITTED BY CODE AND AND OTHER REQUIRED ACCESSORIES. BLADES OUT OF AIRSTREAM, AND BE RATED FOR 1-1/2 HOURS MINIMUM (UNLESS REVIEWED BY: BB 5.2 EXTEND ALL MANUFACTURER'S WARRANTIES TO OWNER, INCLUDING FIVE (5) YEAR SHALL NOT BE INSTALLED IN RETURN AIR PLENUMS. NOTED OTHERWISE). COMPRESSOR EXTENDED WARRANTY ON HVAC EQUIPMENT. SHEET NO. MECHANICAL SPECIFICATIONS 1 NTS i 1 KEY: enne _ 100 SALES AREA 10'-0" GWB-P6 CEILING MATERIAL Architecture CEILING HEIGHT Urban Planning n Store Desi _ 9 360 Lexington Avenue Mixed-Use New York,NY 10017 Retail Development www.kennethpark.com 101 STOCK ROOM 100 SALES AREA 12' " ACT i l'-0" GWB-P6 MEP Consultant 0 NOTE: SUSPENDED CEILING ALL CEILINGS SHALL BE SUSPENDED FROM PURLINS,TOP don p enn a consulting engineer CHORD OF BAR JOISTS, BEAMS AND/OR FLOOR 635 Westport Parkway Suite 300 DECKING. NO ATTACHMENT TO ROOF DECKING WILL BE Grapevine,Texas 76051 PERMITTED. Phone:817-410-2858 Fax:817-251-8411 3 SEAL: NOTE: NIGHT LIGHTS&EMERGENCY LIGHTS PROVIDE SEPARATE CIRCUITS FOR NIGHT LIGHTS AND EMERGENCY LIGHTS. PROVIDE BACK OF HOUSE LIGHTS -- - - - -- - - - --- -- - — - -- -- -- --- ON AT LEAST 2 DIFFERENT CIRCUITS FOR (�J2 (1 _ jJ2 a FOR CIRCUITING SEE SHEET E2. 'L-13b CONTROLLABILITY. S - - L-7b �, I L-9b 4/NL FX4 j J 3 C ® j B B B B B i �\�� ��� 4 I 8W i T8 ! 3 i cVI> Uj - - - - 4 1 r A q q jq q y q rzdi V t NOTE: FIXTURE MOUNTED LIGHTING ❑ 1 - ❑❑ SEE FIXTURE DETAILS ON SHEET A401 FOR PROPER'J2' - - - - L-11 b r g` ! y� FIXTURE MOUNTED LIGHTING INSTALLATION. ! 1 ;A 9c A i. I Y L-13q L-19b M U)J2 d AO -7a,9 - - 9a 9a - 7a a 76 ` A i A A/NL 6 A ! A A A/ L ...: - a W EM 1 ......... '13 A 7a A = - L-1 3a m A ! I NOTE:ACCESS PANELS G.C. IS RESPONSIBLE FOR PROVIDING ACCESS PANELS F4 _ _ I /N L ani qa 9a 9a 9a THROUGHOUT THE LEASED PREMISES. G.C.SHALL AT 041 ; a a c 7d A 4 MINIMUM PROVIDE 24 X 24 FLUSH MOUNT ACCESS � W A A ; A ;A A ! a' PANELS IN THE CEILING WITHIN THE LEASED PREMISES AT 9a. 7a 9q g B B T8W B •'B T4 B i DAMPERS, HVAC EQUIPMENT AND ELSEWHERE AS J REQUIRED BY LANDLORD OR AS REQUIRED BY CODE IN 1 3 L-15 ORDER TO PROVIDE ACCESS TO EQUIPMENT. M4 _ _ Mil �e _ u 2 L-11 a 1 J2 1 J2 S 1)J2 _ �J2 _ WJ2 _ 5 y \—05 )TYP. NOTE:SPEAKERS PROVIDE POWER AND WIRING TO SPEAKER RUNS TO STOCK ROOM.SPEAKER LAYOUT,QUANTITIES AND SPECIFICATIONS AS DETERMINED BY AUDIO CONSULTANT SHALL BE CO-ORDINATED WITH OWNER 9'-11" GWB-P1 AND ARCHITECT. 12'-0" GWB-P6 8'-10" GWB-P6 05-02-13 ISSUE FOR LANDLORD & PERMIT 04-19-13 PRELIM PACKAGE ISSUE DATE REVISIONS KEY PLAN: Y.± e IN, � :. &r S 'r/`���y',#�•��£�' �s,'. ��r d /� s� y#'s ss�h�tw 'r�s s k3 Mn S jr 'y�lg9f i t 3 3 fir£ q;�. .� £ ��✓��� LIGHTING PLAN 1 -- L'OCCITANE SPACE #H6 1. EMERGENCY LIGHTS TO BE INSTALLED ON SEPARATE CIRCUIT,ON SALES FLOOR. SYMBOL TYPE MANUF. MODEL# LAMP QTY. RESPONSIBILITY SYMBOL TYPE MANUF. MODEL# LAMP QTY. RESPONSIBILITY LOCATION: 1 EMERGENCY/EXIT/NIGHT LIGHTING IN STOCK AREA SHALL BE CONNECTED TO LOCAL CIRCUIT ON UNSWITCHED LEG. 2. ALL EQUIPMENT SHALL BEAR U.L. LABELS. EMERGENCY LIGHT L' OCCITAN SWITCH LOCATIONS FOR CONTROL OF STORE LIGHTING.TGC SHALL PROVIDE ALL 3. ELECTRICAL CONTRACTOR MUST PROVIDE AN IDENTIFICATION NAMEPLATE ON ©.. ....... DUAL HEAD,RECESSED, ENCORE EMR-12-100-250-PT SOW MR16 2 L'OCCITANE q AMB E T/ACCENT NORDIC LIGHT MEDIUM1 EAM MT 35 W, G12 33 L'OCCITANE 2 TENANT'S MAIN ELECTRICAL SERVICE FUSIBLE DISCONNECT SWITCH IN EM1 CONCEALED ......... WHITE 3000K LABOR AND MATERIALS INCLUDING BUT NOT LIMITED TO CONTACTORS, ENCLOSURES, RECESSED LIGHT EN PROVENCE LANDLORDS DISTRIBUTION PANEL. NAMEPLATE MUST BE 1/8 THICK PLASTIC, CONDUCTORS, ETC.TO PROVIDE A COMPLETE SYSTEM.VERIFY EXACT LOCATION UNIV. DUAL HEAD -------------------- �- ---- - ---- - - - -- - - --- --- ---- - -- BLACK ON WHITE ETCHED TO LEAVE WHITE LETTERS. THE SIZE SHALL BE ONE INCH ---- PRIOR TO INSTALLATION. 32W MR16 ISI EXC2-32-X-R-U-W INC. 2 L'OCCITANE '<` HIGH BY REQUIRED LENGTH, WITH TENANTS SPACE NUMBER ENGRAVED ON IT. BOUTIQUE 057 EX4 EMERGENCY UNIT _ A LOGO PERMANENTLY AFFIX TO DISTRIBUTION PANEL. WASHINGTON RE MALL 3 SEE SHEET E300 DETAIL 1 FOR CURRENT LIMITER SIZE CHART. GTON $QUA ..-�,....._.... ECI6RWWU,6"RED LETTERS — - — -- ----- - - ....._ ..._....__.............. _ .. ...................................._. .. ...... .......... _.......... . ......._. 4. ALL FIRE DAMPERS MUST BE IDENTIFIED BY A STICKER INSTALLED ON CEILING RECESSED EXIT SIGN ENCORE ON EDGE LIT CLEAR LED INC. 1 L'OCCITANE T2W TRACK, FOR SURFACE LT2P (WHITE) 0 SPACE #H6 BELOW. DUCT FIRE DAMPER MUST BE INSTALLED WITH A BREAKAWAY EX1 ACRYLIC,WHITE TRIM 9585 SW WASHINGTON SQ. RD. q HOME RUN THROUGH CONTACTOR CONTROLLED BY TIME CLOCK.CONTACTOR CONNECTION. PLENUM CANNOT CONTAIN ANY COMBUSTIBLES. _ _ T4W MOUNT TO FASCIA, LT4P (WHITE) 2 -------____--_ ---__-- --_.___-- _.- - _- _ -_ CONTECH NA L'OCCITANE SHALL BE WALL MOUNTED ADJACENT TO PANEL. 1 HR RATED 15/6'HEAVY DUTY T-BAR SYSTEM T6W SEE DETAIL DWG LT6P (WHITE) 0 TIGARD, OR 97223 5. IF REQUIRED,ALL LIGHT FIXTURES SHALL BE TENTED IN ACCORDANCE WITH ACT CEILING T8W 1-A400) LT8P (WHITE) 5 UNDERWRITERS' LABORATORIES #P231 2'x 2'x 3/" ARMSTRONG EXPOSED GRID (AS PER ASCE STANDARD G.C. S REFER TO SHEET E200 FOR CONNECTION OF SKINCARE WALL UNIT FLUORESCENT LIGHT — a 13.5.6.2.2).SEE FINISH SCHEDULE-FOR SPECS._ TRACK MNTD. LED - - - - AREA: 621 SF HORNET 15 LED E WT FIXTURES. 6. SEE SEISMIC BRACING/SUPPORT DETAILS ON FRAMING/SEISMIC DETAIL SHEET IF B HORNET FIXTURE @ AMERLUX CFT-120-FL-3000 LED/120/FL/3000 15W 13 L'OCCITANE REQUIRED BY BUILDING DEPARTMENT. G.C. RESPONSIBLE FOR ROUGH IN, INSTALLATION BY DMX,G.C.TO PERIMETER SOFFIT. ® AUDIO SPEAKER COORDINATE. 2 DMX G EMERGENCY/EXIT/NIGHT LIGHTING IN SALES AREA SHALL BE CONNECTED TO --- -- -- - -- - - - - SHEET TITLE. DEDICATED CIRCUIT ON UNSWITCHED LEG. G.C. RESPONSIBLE FOR ROUGH IN &WIRING, INSTALLATION BY SHOPPER H LIGHTING „:. SHOPPER TRACK 1 „#. SHOPPER TRACK, G.C.TO COORDINATE. TRACK w " -- - ------ _. _ ._. . _ _____ _ _ PLAN 1 TC4W TRACK HUNG FROM IGUZZINI 3' (WHITE) 1 L'OCCITANE GFRG ACCESS PANEL TR-APO 18 (18"x 18") CLG @ STOREFRONT / \ WIND-LOCK SEE NOTE: ) G.C. � (SALES AREA) ROUGH OPN'G.=24"x24" ACCESS PANELS TRACK MNTD ZOOM SPOTLIGHT WITH ......................_ C SPOTLIGHT FIXTURE @ IGUZZINI STRAIGHT ROD 50W 4 L'OCCITANE SUPPLY AIR DIFFUSER/ _--- WINDOW TABLE - - --- ____-_------_- -- _ 50W 12 V QR CBC 51 -_ - _-- __ ---_- PROJECT NO. 13-1802 S401-24/30/WH,22 7W RETURN AIR GRILLES SEE MEP G.C. FIXTURE MOUNTED T5 LED STRIP W/3000K _ � ,1 ® /A (SEE MECH.DWGS.) LINEAR LED JESCO LIGHTING INCLUDED 29 L'OCCITANE SCALE. 1/411 1 -0 _- _ WHITE,SG-BM, COM. - - - - GRADE BOX :r J2 (3) WIRE JESCO LIGHTING SG CABLE NA 16L'OCCITANE DATE: 04/17/13 CONNECTING CABLESG-CC24 112" 24 CABLE 3 (3)WIRE PWR CORD/PLUG JESCO LIGHTING SGPC24-W NA 7 L'OCCITANEDRAWN , KJ# •, W 4' DEC `; 2/32 OR G4 FLUOR WALL/CLG FIX MERCURY LIGHTING MP682320CTASWELB120 SYLVANIA 3 L'OCCITANE ELB UNIV BY. REVIEWED BB LINEAR LED @ e 3000 K LE INCLUDED, G , <'' _ CEIL NG COVE PHILIPS 1 ff 523-000065-13 re PROVIDE MOUNT TRACK& 5 L'OCCITANE SHEET NO. f WALL GRAZER 4 ft: 523-000065-21 LEADER CABLE AS REQ D 3 LIGHTING KEYED NOTES 4 LIGHTING GENERAL NOTES 3 CEILING PLAN SYMBOL LEGEND 2 NTS NTS NTS kennethpark ALL SAW CUTTING/CORING OF MALL FLOORING MUST "ALL LOW VOLTAGE WIRING TO BE IN CONDUIT UNLESS BE COORDINATE WITH MALL SITE REPRESENTATIVE OTHERWISE APPROVED BY AUTHORITY HAVING PRIOR TO THE START OF CONSTRICTION. JURISDICTION". Architecture Urban Planning Store Design X-RAYS OF PROPOSED FLOOR AREA MUST BE REQUIRED Mixed-Use Ne Lexington Avenue New York,NY10017 PER MALL MANAGEMENT BY A LANDLORD APPROVED Retail Development www.kennethpark.com LICENSED X-RAY CONTRACTOR.VERIFY WITH MALL ON-SITE REPRESENTATIVE PRIOR TO THE START OF CONSTRUCTION. MEP Consultant .. .y ;,. G.C.TO PROVIDE J BOX FOR: (2) 20A DEDICATED QUADRUPLEX OUTLETS (TYP). 101 STOCK ROOM 100 SALES AREA,-] don penn a consulting engineer SINGLE PORT CAT 6 NETWORK SINGLE PORT CAT 6 NETWORK 635 Westport Parkway JACK: EMPLOYEE TIME CLOCKJACK: MENS (BEHIND MENS Suite 300 G.C.TO PROVIDE J BOX& 1.5"CONDUIT FOR (8) CAT (NJ THERMOSTAT(S) TO BE LOCATED 12 CABLES TERMINATING AT THE TELE/DATA PATCH UNIT FIXTURE) Grapevine,Texas 76051 Phone:817-410-2858 AS REQUIRED REFER TO MEP FOR PANEL AT I.T.CABINET; (4) FOR EA. EPOS UNIT(TYP). SINGLE PORT CAT 6 NETWORK Fax:817-251-8411 ADD'L INFORMATION (TYP). NOTE: RUN RIGID CONDUIT FROM J BOXES AT WALL JACK: FRAGRANCE#3 (BEHIND (N) SWITCH BANK TO OUTLETS ATTACHED TO THE INTERIOR OF THE FRAGRANCE UNIT FIXTURE) SEAL: CASHWRAP. REFER TO ENGINEERS ELECTRICAL PLANS FOR ADDITIONAL INFO (TYP). 4 PORT NETWORK JACK UNDER G.C.TO PROVIDE J BOX FOR CASH DESK LIGHT MANAGER'S DESK,INSTALL HOUSE FIXTURES;SEE RCP FOR SPECS. � WIRING RUN FROM MANAGER'S NOTE:ALL FIXTURE MOUNTED LIGHTS TO BE ON .� DESK TO I.T.CABINET(TYP). ► DEDICATED CIRCUITS W/SWITCH CONTROL.SWIT ES � TO BE LOCATED BOH @MAIN SWITCH BANK (TY �\O�P )0 tY CC zO V r� NEW WALL MOUNTED I.T. CABINET BY G.C.TO 22' El ACCOMMODATE AUDIO, 18 L-10b TRAFFIC COUNTER&LOW OVOLTAGE/DATA/TELECOM I4" L-10 4848484860 60 SINGLE PORT CAT 6 NETWORKSYSTEMS (TYP).SEE DETAIL 84.E L-l0a T `. ` JACK ABOVE CLNG: FOR VA103. 1 " WIRELESS ACCESS POINT L-4a 0L-1,3,5 L-7b ..... -1 7a SINGLE PORT CAT 6 NETWORK SINGLE PORT CAT 6 NETWORK 0 JACK ABOVE CLNG JACK:SKINCARE#2 (BEHIND L-1 5b EXISTIG 30 MP J SKINCARE UNIT FIXTURE) L-2b L-12b L-2a DISC OR V V L-19a G.C.TO PROVIDE (1) DUPLEX (83"AFF) FOR EVERY GROUP OF I CLG.MOUNTED DUPLEX FRAGRANCE WALL UNIT LIGHT FIXTURES;SEE RCP FOR SPECS. RECEPTACLE. L-6b NOTE:ALL FIXTURE MOUNTED LIGHTS TO BE ON DEDICATED I J BOX FOR SUSPENDED CIRCUITS W/SWITCH CONTROL.SWITCHES TO BE LOCATED TRACK LIGHT FIXTURE, (TYP). 18" L-12a BOH @ MAIN SWITCH BANK (TYP). L-12a (E) ELECTRICAL PANELS TO L-8b L-17b REMAIN,SEE MEP FOR MORE NOTE: EXISTING POWER FOR INFO. 64.5" ,f lg" - ROLL UP GRILLE TO REMAIN; GC TO REFURBISH TO LIKE - NEW CONDITION. REF. NOTE: M/WAVE SINGLE PORT CAT 6 NETWORK NOTE: ELECTRICAL OUTLETS&WALL PLATES COLOR REF. ALL LOW VOLTAGE WIRING TO BE IN CONDUIT JACK: FRAGRANCE #1(BEHIND ALL NEW ELECTRICAL OUTLETS AND WALL PLATES IN UNLESS OTHERWISE APPROVED BY"AUTHORITY SINGLE PORT CAT 6 NETWORK FRAGRANCE UNIT FIXTURE) SALES AREA SHALL BE LUTRON 'DECORA'STYLE W/ HAVING JURISDICTION." JACK:SKINCARE#1(BEHIND 05-02-13 ISSUE FOR LANDLORD & PERMIT 'DESIGNER'COLOR WALL PLATES; SKINCARE UNIT FIXTURE) -AT TYP. P-1 SALES AREA WALLS- (CUSTOM COLOR- P-4) G.C.TO PROVIDE (2) DUPLEXES (22"&83" GC TO PROVIDE'Y BOX FOR NEW 04-19-13 PRELIM PACKAGE ISSUE NOTE: STOREFRONT SIGNAGE.GC TO COORDINATE -A T-1 SALE AREA TILED WALLS-—BR (BROWN,O N G.C.TO VERIFY LOSS PREVENTION SYSTEM AFF) FOR GROUP F SKINCARE CONDUIT RUNS WITH SIGN VENDOR. ARCHITECTURAL MATTE FIN. WALL UNIT LIGHT FIXTURES;SEE RCP FOR 0 DATE REVISIONS REQUIREMENTS W/P.M.GC TO COORDINATE SPECS. NOTE:ALL FIXTURE MOUNTED -AT TYP. P-6 GWB CEILING-SW (SNOW,SATIN FIN.) ONSITE AS NECESSARY. ALL NEW ELECTRICAL OUTLETS AND WALL PLATES IN BOH LIGHTS TO BE ON DEDICATED CIRCUITS W/ NOTE:ALL SIGNAGE AND DISPLAY WINDOW LIGHTING KEY PLAN: AREA SHALL BE WHITE. SWITCH CONTROL.SWITCHES TO BE SHALL BE ILLUMINATED DURING MALL HOURS AND 3S� -E < f<r zryNi�rkrYxs fil yn3yyS„ J£ iFs:. GC MUST CONFIRM COLOR SPECS WITH ARCHITECT LOCATED BOH @ MAIN SWITCH BANK (TYP). CONTROLLED BY A SEPARATE 7 DAY/24 HOUR TIME CLOCK. PRIOR TO ORDERING COVER PLATES. NOTE: LOW VOLTAGE/DATA/TELECOM SYSTEM REFER TO STOREFRONT&ELECTRICAL DWG'S FOR FURTHER µ G.C.TO RUN LINES FROM THE SPECIFIED (N) CEILING MOUNTED REMOTE � a SINGLE PORT CAT 6 NETWORK DETAILS.GC TO VERIFY WITH L OCCITANE PM&MALL - sr�yY, �� TEMPERATURE SENSORS TO BE NETWORK JACK LOCATIONS TO THE I.T. OOPERATIONS < n .. . IFAGE WIND W DI PLAY F ..,. ..;.. . - .. ;. SIGN & O S JACK: FRAGRANCE#2 BEHIND . .....,... : . .: .. ; � LOCATED AS REQUIRED REFER TO ( ., ��� MR'��' ” CABINET TELE/DATA PATCH PANEL IN THE LIGHTING IS TO BE WIRED TO NEW DEDICATED �_ ��- � NOTE:CUSTOM COLOR OUTLETS P-4 STOCK ROOM (TYP). PROVIDED MEP FOR ADD'L INFORMATION (TYP). FRAGRANCE UNIT FIXTURE) ' ( ) CIRCUIT/TIMER OR IF TO BE CONNECTED TO LANDLORDq. P-4 CUSTOM OUTLETS PROVIDED BY LOCCITANE, BY LOCCITANE VENDOR. REFER TO REQUIRED CIRCUIT/TIMER. ss�r INSTALLED BY GC.TOTAL P-4 COUNT: 12 ELECTRICAL DWGS FOR ADD'L DETAILS 7041 R H ��Nf POWER PLAN 1 L'OCCITANE 1/411 = 1'-0" SPACE #H6 LOCATION: 11. ALL TELEPHONE OUTLETS SHALL BE PROVIDED WITH 2 (TWO) PULL STRINGS BACK TO 1. ALL OUTLETS SHALL BE INSTALLED AS DIMENSIONED ON THIS PLAN. ANY SYMBOL MANUF. REMARKS SYMBOL MANUF. REMARKS THE TELEPHONE EQUIPMENT. DISCREPANCIES AS TO LOCATION BETWEEN PLAN AND EXISTING FIELD CONDITIONS SHALL BE CLARIFIED WITH THE ARCHITECT BEFORE COMMENCEMENT OF WORK. 12. THE GENERAL CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING OF ALL DQ GROUNDED 15 AMP DUPLEX RECEPTACLE N DATA CABLES/FAX LINE RECEPTACLE L' OCCITAN WALL AND A REQUIRED. 2. ALL ELECTRICAL AND TELEPHONE WORK SHALL BE INSTALLED IN STRICT CHASES IN FLOOR, S CEILING S S LLED S C EN PROVENCE ACCORDANCE WITH THE ELECTRICAL CODE,NATIONAL BOARD OF FIRE --------------._.._.._....._...____......_.._....-......__.._....-.._..___-------------------------------._...--._..----..-......----- ----------.---......--- 13. ALL SURFACES WITH EXISTING OUTLETS TO BE REMOVED,SHALL BE PATCHED FLUSH UNDERWRITERS, PUBLIC UTILITIES COMPANY,TELEPHONE COMPANY,AND ALL GROUND FAULT INDICATOR 15 AMP DUPLEX RECEPTACLE LOCATED IN REST ROOM 14 DOUBLE JACK TELEPHONE RECEPTACLE BOUTIQUE #057 WITH ADJACENT WALL SURFACES. OTHER AUTHORITIES HAVING JURISDICTION. GFI WASHINGTON SQUARE MALL 14. EXCEPT WHERE NOTED,ALL ELECTRICAL, TELEPHONE,AND DATA OUTLETS ARE TO BE 3. ALL NEW ELECTRICAL OR TELEPHONE OUTLETS SHALL BE RECESSED MOUNTED.THERE ISOLATED GROUND 15 AMP DUPLEX SPACE #H6 MOUNTED VERTICALLY 18"A.F.F. SHALL BE NO NEW SURFACE MOUNTED CONDUIT OR OUTLETS. RECEPTACLE (ORANGE) -DEDICATED OUTLET b COMBINATION VOICE/DATA OUTLET/RECEPTACLE 9585 SW WASHINGTON SQ. RD. - ---------- -- ---------------- ---- - -- . OR 97223 15. CENTERLINE TO CENTERLINE DIMENSIONS OF ANY OUTLET PAIR OR GROUP SHALL 4. IT IS THE INTENT OF THESE PLANS TO PROVIDE A COMPLETE OPERATING ELECTRICAL TIGARD, NOT EXCEED 6". SYSTEM.G.C.SHALL FURNISH AND INSTALL WIRING, EQUIPMENT, ETC. REQUIRED. ® GROUNDED 15 AMP DUPLEX MTD. IN CLG.-FLUSH MTD. POWER PANEL LOCATED AS PER CODE AFF EXISTING' L PANEL. PROVIDE 5. ALL WIRING INSTALLED UNDER THIS CONTRACT SHALL BETESTED FOR PROPER - - ---- -- - -- — — _ -._._........_............----------- ----- - --- - - — -----------...--- - _.._.._........... ..........-........_.__...-_.............. _.._...------------------- - _._.-. ------ -----_..__ ----- ------- ------ ---...._......................_........ AREA: 621 S F 16. PROVIDE MINIMUM 10�SPARE CIRCUITS N ISTI G ELECTRICAL S C -- BREAKER LOCKOUTS FOR A.C. UNITS AND SEPARATE CIRCUIT OUTLETS AT TELEPHONE CONNECTIONS SHORT CIRCUITS AND GROUNDS PRIOR TO TURNING OVER THE GROUNDED 15 AMP DOUBLE EQUIPMENT. WORK AS A COMPLETE UNIT. DUPLEX RECEPTACLE FIRE ALARM MANUAL PULL STATION LOCATED AS PER CODE AFF SHEET TITLE: 17. TELEPHONE PANEL TO BE MOUNTED ON A 18"X 24"PTD. PLYWOOD SHEET MOUNTED 6. G.C.TO REFER TO ELECTRICAL DRAWINGS FOR IT/TELECOM LINE DIAGRAM. FIRE ALARM STROBE/SPEAKER SIGNAL DEVICE LOCATED AS PER CODE AT 48"A.F.F.W/AN OUTLET MOUNTED AT 60"A.F.F. ® GROUNDED 15 AMP QUAD MTD. IN CLG.-FLUSH MTD. 0 AFF POWER PLAN 7. SEE COLOR REFERENCE NOTE ON PLAN FOR OUTLET COVER PLATE SPECIFICATION 18. LL PANELS AND BRANCH CIRCUITS IN PANELS SHALL BE LABELED IN A CLEAR LEGIBLE INFORMATION. MANNER. $ LIGHT SWITCH QA ALARM KEYBOARD SEE SHOP DRAWINGS FOR WIRING 8. ALL EXISTING OUTLETS TO REMAIN SHALL BE REPLACED WITH 'DECO RA'STYLE 17. ALL WORK MATERIALS AND EQUIPMENT TO BE GUARANTIED FOR A PERIOD OF ONE COVERPLATES AND'DECORA'TYPE DEVICE, IF REQUIRED.SEE NOTE#7 ABOVE - ...... ............ -........ - -.....--------- -- ---- - — — -- - -- - -- PROJECT NO. 13-1802 YEAR FROM DATE OF FINAL ACCEPTANCE. REGARDING COLOR. BD DOOR CHIME AT CEILING @ STOCKROOM &CASHWRAP FIXTURE 0 VOLUME CONTROL - 1,-0„ 9. THE G.C.SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL ELECTRICAL WIRING, SCALE: 1/4„- OUTLET INSTALLATION,AND CONNECTION OF POWER FEED OUTLET BOX AT ALL • K ROOM DOOR J JUNCTION BOX SEE ELEC. DRAWINGS FOR WIRING DATE: 04/17/13 p LOCATIONS. � PUSH BUTTON FOR STOC 00 00 O 10. EXACT LOCATION FOR CORE DRILL POWER FEEDS SHALL BE FIELD VERIFIED PRIOR TO ^� _ -- u J DRAWN BY: KJ CORING.G.C.SHALL COORDINATE WITH ARCHITECT&LL PRIOR TO CORE DRILLING. ARNEV PRODUCTS RECESSED FLUSH MOUNT BOX: GROUNDED 15 AMP DUPLEX FLOOR RECESSED-FLUSH MTD. AP-1102-58 (RECTANGULAR-DOUBLE FOR CONCRETE QT THERMOSTAT SEE MECH. DRAWINGS FOR WIRING NO TRENCHING ALLOWED FLOORS) W/AP-6304-DP COVER PLATE REVIEWED BY: BB ® CEILING RECESSED DATA PORT QS TEMPERATURE SENSOR SEE MECH. DRAWINGS FOR WIRING SHEET NO. POWER/SIGNAL PLAN NOTES 3 SYMBOL LEGEND 2 NTS NTS LOAD SUMMARY 1 +�08 1E^I 1201208V208V 3 PH " 4' STING PANEL L enneth ar Se ice: 1201208 '/oits 3 Phaso. 4 V ire Cabinets: Surface Mounted LOAD DESCRIPTION CONNECTED AMPS DEMAND DEMAND AMPS Mans: 125 Amp I Y11-0_ Total Wottsy 19212 NEMA 1 LOAD (KW) LOAD (W} REM CKT DESCRIPTION WATTS WIDE BIER A B C B:KR WIRE DESCRIPTION WATTS CIT REM LIGHTING 499 ,17 5.0 9.25 5238.8 14.08 ''Fy POS 2a DED Architecture Urban Planning SIGNS .L{�j/^�y]�'�,(} (jam +{�+j''�' {8{8 a''/� j$ 11,20 /}} III}}} �[^�J V{*�/ii aT .(�Y V.i/ .L S 4 4J. 9 • - 12 POS 4 DE.Yl ,:; �:�; Store Design ;yam' ' ' �' �� �� IT CA®INET 360 Lexington Avenue RECEPTACLES 0.7 1.OQ 67$Q.0 18.8 HR E HVAC X47 10 3 `y y " Mixed-Use MVAC , 9.9 1.25 10309.3 28.6 .3 Y 120 12 SHQWIN REG_ 4b C1 New York,NY10017 Retail DevelDevelopment www.kennethpark.com WATER HEATER 0.0 1.40 0.0 0.0 � � 's tip 5� 1120 12 TC/CONTACTOR LD TOTAL 99212.0 18.1 23$2E .0 8fi.2 4 s=!: 1f 12 REFRIGERATOR f=yx 6b LID NOTES: 7a SALES LIGH71ING 2 12 1/20 1120 SPARE ', 8a MEP Consultant 1. 100% OF FIRST 10,000WATTS , PLUS 50% OF REMAINING LOAD. C'I 7b STOREFRONT TRACK 12 1/20 1.2 MICROWAVE �f1 8b l . 1/`.20 2. 100% OF ASC LOAD, PLUS 25%OF HIGHEST LOAD. ALE LIG 11( G 4 12 1I / ; 1�� 12 MANAGERS DESK ��;��� 10!a 3 s TOCIRII LTA 12 12fl ''s? y ', 1 12 B_O.H. RECP : r 10bah C2 11a TRACK LIGHTS 120 12 120 y � '�" ���,' 1 :20 12 SALES RECD. Ir I2a C2 11b TRACK LIC3HI 1 12 1� ,. 1,F 12 POS RECE PT s F; 12b LD 13a EMERGENCY/ IGHTLT X70 12 1120 .1, % 1120 SPARE 1 . X �'/ don penn consulting engineer C2 1C3b TRACK LIGHTS.TS 24� 12 1120 j�3 �5 1� SPARE 14b 635 Westport Parkway C1 15a SW LIGHTS 70 12 1/20 � 1/20 SPARE 1 y Suite 300 C2 �(- DISPLAY CASE RECE PT 0 92 120 y 1/201SPARE 16b Grapevine,Texas 76051 C1 17a STOREFROI TSIGN 12 120 ; e V20 SPARE I Phone:817-410-2858 CASE s Fax:817-251-8411 C2 `17b DIS PLAY CASE RECEIPT ` 12 1! : l 1/20 SPARE 18b C2' 1 PA's COUNTER LIGHTS 92 1/20 .F 1/20SPARE 20 G c� y. SPARE 20b SEAL: C2 1 CEILII' COVE. Q 1�' 12 1/20 120 TOTAL LOAD PHASE A X22 REMARKS TOTAL LOAD PHASE 'B' 8343 DED DEDICACATEDGROUND TOTAL LOAD PHASE 'C' 8247 HIS BREAKER SHALL B E "HACK"RATED _..® LD BREAKER.TO HA1,1E LOCK-ON CUPS AND RED MARIKING TOTAL LOAD ALL PHASES 19212 WATTS � C#CIRCUIT Otd CONTACTOR :53 AMPS Gj a N Uj 0- r� c L.a.� M LIMITER CONTECH REGI 1 AMP/120W LIMITER CONTECH REG3 2.5 AMP/300W I.6 E13 L..i1 ".{..' `�F£„ ..:3 H6 S?5...*.�.�4..`' 5: EY E j\'^..�0VV CONTECH ?,, : ,li { f n#sl :& 3 s MITER - �^ �e REG £ l z1'. z C1 14 APOP'l 6-010W 05-02-13 ISSUE FOR LANDLORD & PERMIT ELECTRICAL PANELS/CURRENT LIMITERS AND RISER 1 _ _ NOT USED 3 04 19 13 PRELIM PACKAGE ISSUE NTS NTS DATE REVISIONS KEY PLAN: T.G.C.SHALL REUSE EXISTING ELECTRICAL SERVICE IF IT MEETS ORJCPm key sr EXCEEDS THE LOADS SHOWN.SIZES SHOWN ARE MINIMUM REQUIRED BASED ON TENANT'S LOADSMERIFY EXACT SIZE AND �.' � ��l3y"�" q�qr f'Y�i /• r�"k. ^a sof`�i. LOCATIONS IN FIELD. NOTIFY THE FIELD REPRESENTATIVE AND �� s�� PIN n,�,s'`� Fx l tilzaY7 I's ENGINEER IF EXISTING ELECTRICAL DOES NOT MEET THE REQUIRED PF AS SHOWN. , ���� �s#��F•,,�• ���� � y .. / ° EXISTING 30A 2Y7TIMECLOCK SHALL CONTROL THE FOLLOWING: jp' € � ' -STOREFRONT SIGNAGE � DISCONNECT FOR � y -SHOW WINDOW LIGHTING f . EX.VAV � .. T. SALES LIGHTING ( L-9a) -SHOW WINDOW RECEPTACLES -ENTRY LIGHTINGADSTROM � Y y l f • ;, �� j ' SALES LIGHTING ( L-7a) TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL EX 3 #10 THWN CU. COPPER CONDUCTERS. O L OCCITANE G.C.TO COORDINATE STOREFRONT TIME (1) #10 G-3/4"C. HOMERUNS AND BRANCH WIRING FOR 20 AMP CIRCUITS SHALL SPACE #H6 CONTROL WITH LANDLORD TIME LIGHTING BE AS FOLLOWS: SCHEDULING. LIGHTING CONTACTOR #1 Z LENGTH CIRCUIT WIRE SIZE HOMERUN WIRE SIZE LOCATION: J ( 1 FT TO 50FT NO.12 AWG NO.12 AWG C2 Q 76FT TO 120FT NO.10 AWG NO.10 AWG 8 AWG 0-2 HOUR OVERRIDE 1 191 FT TO 30OFT NO.10 AWG NO.4 AWG L- 5b CASE RECEPTS CCITAN SWITCH.LOCATE NEAR L-17b CASE RECEPTS EX (4) #1 THWN, #6 LIGHT SWITCH LOCATION. L-11 a TRACK LIGHTS GND IN 1-1/2"C.TO I EN PROVENCE L-1 I b TRACK LIGHTS L-13b TRACK LIGHTS REMAIN.VERIFY IN BOUTIQUE #057 FIELD. I �-19a - PAY COUNTER LIGHTS I WASHINGTON SQUARE MALL SPARE 1 CEILING SPACE #H6 TIME CLOCK#2 TIME CLOCK 7 DAY TYPE TORK SERIES. 9585 SW WASHINGTON SQ. RD. Tc2 r- TC C1 TIGARD, OR 97223 o----I I 0---iSTOCK LIGHTING (L-9b) (E)3Pi100A DISC. ` EXISTING 8p 0---AF--o I PANEL A AREA: 621 S F o I 100 AMP I I M.L.O. TC1 C SHEET TITLE: LIGHTING I T(M") I 8p TIME CLOCK#1 CONTACTOR #2 � M �--- -� TRI A L SPECS,RKR BRKR ELEC C TC1 C1 (M� (M� PANELS & RISER °� � BRKR I BRKR 0-1117-0L-17a STORE FRONT SIGN I L-7b STORE FRONT TRACK L-15a STORE FRONT LIGHTS ( O I (M� I (M� I I PROJECT N0. 13-1802 L-4b SHOW WINDOW RECEPTACLE SPARE BRKR BRKR SPARE I SCALE: 1/4" = 1'-0" SPARE SPARE D D (M� (M BRKR BRKR DATE: 04/17/13 L-6a (HOT) DRAWN BY: KJ (NEUT) REVIEWED BY: BB SHEET NO. BUILDING SHUT OFF DETAIL 4 RISER DIAGRAM 2 NTS NTS I DIVISION 16050 - BASIC MATERIALS AND METHODS DIVISION 16060 - GROUNDING AND BONDING 1.2 CONDUIT SIZE SHALL BE 3/4"MINIMUM. 1.6 RECEPTACLES REQUIRING AMPERAGES,VOLTAGES OR 1.2b2 INSTALLATION OF EXTERNAL CONTROL DEVICES AND WIRING TO THE CONTROLLER. h k CONFIGURATIONS DIFFERENT FROM THE DUPLEX CONVENIENCE enne ar 1.0 NAMEPLATES 1.0 GROUNDING AND BONDING 1.3 CONDUIT SHALL BE SECURELY FASTENED IN PLACE. RECEPTACLES ABOVE SHALL BE AS INDICATED ON THE DRAWINGS. 1.2b3 INSTALLATION OF COMMUNICATIONS CONDUCTORS AND ASSOCIATED HARDWARE. 1.1 GENERAL: FURNISH AND MOUNT ON EACH PANEL BOARD/SWITCHBOARD 1,1GROUND ALL EQUIPMENT PER N.E.C. 1.4 ALL CONDUIT SHALL BE CONCEALED IN WALLS, FLOOR AND CEILINGS WHEREVER 1.7 PROVIDE OTHER RECEPTACLES OF A QUALITY,MATERIAL AND POSSIBLE. EXPOSED CONDUIT IN FINISHED AREAS WILL NOT BE PERMITTED.EXPOSED WORKMANSHIP EQUAL TO THAT SPECIFIED FOR DUPLEX CONVENIENCE RECEPTACLES. 1.3 WARRANTY:MANUFACTURER SHALL WARRANT SPECIFIED EQUIPMENT TO BE FREE (INCLUDING BRANCH SWITCHES), LARGE JUNCTION BOX,SAFETY SWITCH,TARTER, REMOTE - CONDUIT WILL BE PERMITTED IN UNFINISHED AREAS WITH THE SPECIFIC APPROVAL OF THE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR AT LEAST ONE YEAR FROM THE Architecture CONTROL, PUSHBUTTON STATION,AND ALL SIMILAR CONTROLS A NAMEPLATE 1.2 GROUND ALL DRY TYPE TRANSFORMERS AS PER DRAWINGS AND N.E.C. ARCHITECT. 1.8 PROVIDE COVER OR DEVICE PLATES FOR OUTLET BOXES AS FOLLOWS UNLESS DATE OF INSTALLATION OR EIGHTEEN MONTHS FROM DATE OF PURCHASE. Urban Planning DESCRIPTIVE OF THE EQUIPMENT OR EQUIPMENT CONTROLLED. OTHERWISE NOTED: Store Design 1.3 ALL CONDUITS SHALL CONTAIN ACODE-SIZED GROUND WIRE SIZE PER N.E.C.IN 360 Lexington Avenue Mixed-Use 1.2 PROVIDE BLACK AND WHITE NAMEPLATES CONSTRUCTED FROM LAMINATED ADDITION TO THE CONDUCTORS SHOWN ON THE PLANS.WHERE CIRCUIT CONDUCTORS 1_5 USE FLEXIBLE CONDUIT FOR THE CONNECTION TO RECESSED OR SEMI-RECESSED 2.0 PANELBOARDS New York,NY10017 PHENOLIC WITH A WHITE CENTER CORE. LETTERS SHALL BE ENGRAVED IN THE PHENOLIC TO ARE INCREASED IN SIZE FOR VOLTAGE DROP,THE GROUND WIRE SIZE SHALL BE INCREASE LIGHTING FIXTURES (6LENGTH MAXIMUM). USE LIQUID TIGHT METAL CONDUIT FOR ALL 1.8a FINISHED AREAS:THERMOPLASTIC-COLOR TO MATCH DEVICE. Retail Development www.kennethpark.com FORM WHITE LETTERS 3/8"HIGH. FASTEN THE NAMEPLATES WITH SCREWS AND ADHESIVE PROPORTIONATELY. CONNECTIONS TO MOTORS AND OTHER EQUIPMENT SUBJECT TO VIBRATION AND IN 2.1 ACCEPTABLE MANUFACTURERS:SQUARE D,CUTLER HAMMER,SEIMENS, G.E.. FOR FASTENER. AREAS SUBJECT TO MOISTURE. 1.8b UNFINISHED AREAS:ZINC COATED SHEET METAL,ALUMINUM, F OR CAST METAL PRICING AND ORDERING INFORMATION,PROVIDE EQUIPMENT AS SPECIFIED HEREIN, 1.4 WHERE AN ISOLATED, INSULATED GROUND IS REQUIRED A SEPARATE GREEN AS APPROPRIATE FOR THE TYPE OF BOX. NO SUBSTITUTIONS PERMITTED.CONTRACTOR SHALL CONTACT NO LATER THAN 5 DAYS MEP Consultant 1_6 USE WATERTIGHT JOINTS WITH BURIED AND CONCRETE ENCASED CONDUIT.ALL AFTER JOB IS AWARDED TO ENSURE LEAD TIMES DO NOT AFFECT PROJECT SCHEDULE . 2.0 MOUNTING ACCESSORIES GROUND SHALL BE RUN FROM THE PANEL GROUND BUS TO THE ISOLATED GROUND BURIED CONDUIT OUTSIDE OF BUILDINGS SHALL HAVE A MINIMUM OF 24"OF COVER. 1.8c EXTERIOR AREAS: COPPER FREE ALUMINUM WITH GRAY,POWDER EPDXY FINISH, PANELBOARDS SHALL BE ENCLOSED DEAD FRONT SAFETY TYPE WITH FEATURES AND CONNECTION OF THE DEVICE SERVED. IN NO CASE SHALL THE SYSTEM GROUND (WIRE METAL CONDUITS BURIED IN EARTH SHALL BE PAINTED (TWO COATS) WITH HEAVY GASKET, WEATHERPROOF, CROUSE-HINDS"WLRD"FOR DUPLEX RECEPTACLES AND WLRS RATINGS AS SCHEDULED ON THE DRAWINGS. 2.1 THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL ANGLE IRON, CHANNEL IRON, AND ASSOCIATED OUTLET BOXES, CONDUIT AND BUILDING STEEL) BE ALLOWED TO ASPHALTUM PAINT. FOR SINGLE RECEPTACLES OR EQUAL. a a fib RODS,SUPPORTS, HANGERS, CONCRETE OR PLYWOOD REQUIRED TO INSTALL,MOUNT CONTACT THE ISOLATED GROUND (GREEN WIRE AND DEVICE GROUND). 2.2 PANELS KNOWN AS"LOAD CENTERS"ARE UNACCEPTABLE. AND SUPPORT ANY ELECTRICAL EQUIPMENT OR DEVICE CALLED FOR ON THE PLANS. 1.7 SUPPORT RUNS OF CONDUIT AS DETAILED IN THE APPROPRIATE TABLE OF THE 1.8d TELEPHONE COMMUNICATIONS,AND SIGNAL OUTLET PLATES,SHAL MATCH THOSE mmmm 2.2 SUPPORTING MATERIAL SHALL BE COMPLETE WITH HANGERS, CONNECTORS,BOLTS, DIVISION 16120 - WIRE AND CABLE NATIONAL ELECTRICAL CODE(NEC). USED FOR RECEPTACLES AND SWITCHES.ALL OUTLET AND/OR JUNCTION BOXES SHALL BE 2.3 MOLDED CASE CIRCUIT BREAKERS SHALL BE AS SCHEDULED ON THE DRAWINGS don penn a consulting engineer CLAMPS,AND NECESSARY ACCESSORIES TO MAKE A COMPLETE INSTALLATION. COMPLETE WITH A COVER PLATE BY THIS CONTRACTOR. AND SPECIFIED IN THIS DIVISION. 635 Westport Parkway SUPPORTING MATERIAL SHALL BE GALVANIZED, PAINTED OR OTHERWISE SUITABLY1_8 INSTALL EXPOSED RUNS OF CONDUIT AND CONDUIT ABOVE LAY-IN CEILING Suite 300 FINISHED.PRODUCTS BY BINKLEY,STEEL CITY OR RACO WILL BE ACCEPTABLE. 1.0 WIRE AND CABLE PARALLEL OR PERPENDICULAR TO THE WALLS,STRUCTURAL MEMBERS OF INTERSECTIONS 1.8e WHERE DEVICES ARE GANGED,THEY SHALL BE INSTALLED UNDER A COMMON 2.4 ALL BUS BARS SHALL BE RECTANGULAR,SOLID COPPER. Grapevine,Texas 76051 OF VERTICAL PLANES AND CEILINGS.PROVIDE RIGHT ANGLE TURNS USING FITTINGS OR COVER PLATE. Phone:817-410-2858 2.3 ALL SURFACE-MOUNTED EQUIPMENT ON BLOCK WALLS SHALL BE MOUNTED ON 3/4" 1.1 COLOR CODE CONDUCTORS (EXCEPT CONTROL AND INSTRUMENTATION SYMMETRICAL BENDS.SUPPORT CONDUITS WITHIN 1"OF ALL CHANGES IN DIRECTION. 2.5 SPACE, WHERE SHOWN IN PANEL SCHEDULES, DESIGNATES SPACE FOR FUTURE Fax:817-251-8411 PLYWOOD BACKBOARD.ALL FLOOR-MOUNTED EQUIPMENT SHALL BE INSTALLED ON A 4" CONDUCTORS)AS FOLLOWS: 1.9 LOCATE THE SWITCHES APPROXIMATELY 4'-0"ABOVE THE FINISHED FLOOR PROTECTIVE DEVICES AND SHALL INCLUDE BUS AND SUPPORT. HIGH CONCRETE PAD. 1.9 IF A CONDUIT IS SUSPENDED, IT SHALL BE SUPPORTED ON TRAPEZE HANGERS WHICH ELEVATION OR NEAREST BLOCK COURSE (WITHIN A.D.A. REQUIREMENTS),UNLESS SEAL: 120/208 2'701/4$0 USE"ALL-THREAD"RODS FROM THE STRUCTURAL STEEL.THE USE OF CEILING SUPPORT WIRE OTHERWISE INDICATED.THE LONG DIMENSION OF THE SWITCHES SHALL BE VERTICAL. 2.6 INSTALL CABINETS SO THAT CENTER OF THE TOP BREAKER DOES NOT EXCEED 6'-6" 3.0 EXECUTION OR SIMILAR MATERIAL WILL NOT BE ACCEPTED. ABOVE THE FINISHED FLOOR. PHASE A BLACK SROWN 1,10 LOCATE RECEPTACLES APPROXIMATELY 1'-6"ABOVE THE FINISHED FLOOR 3.1 THE ELECTRICAL WORK FOR CONSTRUCTION PURPOSES SHALL CONFORM TO ALL1.10 INSTALL EMPTY CONDUIT FOR FUTURE USE AS INDICATED ON THE DRAWINGS. ELEVATION OR NEAREST BLOCK COURSE (WITHIN A.D.A.REQUIREMENTS), UNLESS NOTED 2.7 ENTRIES ON DIRECTORY CARDS SHALL BE TYPED,COMPLETE AND ACCURATE. FEDERAL (OSHA),STATE,ALL SPECIFIC SAFETY REQUIREMENTS AND THE CURRENT EDITION PHASE B REO ORAN6E CONDUIT SHALL BE COMPLETE WITH JETLINE OR PULL ROPE, JUNCTION/OUTLET BOXES, OTHERWISE THE LONG DIMENSION OF RECEPTACLES SHALL BE VERTICAL. OF THE NEC. TILE RINGS AND APPROPRIATE COVER PLATES. 2.8 ALL BOLTED CONNECTIONS SHALL BE TORQUED IN ACCORDANCE WITH PHASE G BLUE YELLOW MANUFACTURER'S STANDARDS. 3.2 CHECK THE HVAC AND PLUMBING SPECIFICATIONS FOR ELECTRICAL NMJAL WHI11! 6REY 1.11 PROVIDE PITCH POCKETS WHERE CONDUITS PENETRATE THE ROOF. T•R 2.9ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS AS NEAR AS POSSIBLE TO REQUIREMENTS AND INCLUDE THE SAME IN THE CONTRACT COST. �® - ®' c� 6ROUND 6REEN GREEN 1.12 THREAD LUBRICATION/SEALANT IS REQUIRED ON OUTDOOR AND DIVISION 15410 - SAFETY SWITCHES CIRCUIT NUMBERS ON THE DRAWINGS.AT COMPLETION OF JOB,ELECTRICAL ,�� Uj0 3.3 EQUIPMENT CONNECTIONS,STARTERS, DISCONNECT SWITCHES,CONTROL UNDERGROUND THREADED METAL JOINTS. CONTRACTOR SHALL TAKE CURRENT READING CHECKS OF RESPECTIVE PHASES.A 0 14 0, 0 0 V �, MINIMUM OF CIRCUIT CONNECTIONS SHALL BE REARRANGED TO BALANCE AS CLOSELY z � •- � TRANSFORMERS AND PUSH-BUTTON STATIONS FOR THE EQUIPMENT FURNISHED BY THE 1.0 SAFETY SWITCHES M W � OWNER OR UNDER A SEPARATE CONTRACT SHALL BE INSTALLED AND CONNECTED UNDER 1.13 INSTALL FIRE SEAL FITTINGS WHERE CONDUITS PENETRATE CONCRETE FLOOR SLABS AS POSSIBLE,THE LOAD IN THE PANEL. t 00 QC 1.1 a #12 AND #10 CONDUCTORS SHALL HAVE CONTINUOUS INSULATION COLOR, OR MASONRY WALLS REQUIRED TO BE FIRE RATED. 0 THIS DIVISION,AS INDICATED ON THE CONTRACT DRAWINGS. AS LISTED ABOVE. 1.1 SAFETY SWITCHES SHALL BE THE ENCLOSED HEAVY-DUTY TYPE (TYPE HD) WITH 2.10 ALL BREAKERS SHALL BE BOLT-ON TYPE. 1.14 HORIZONTAL PORTION OF CONDUIT EXPOSED ON THE ROOF AND FEEDING QUICK-MAKE, QUICK-BREAK MECHANISM AND EXTERNAL PAD LOCKABLE OPERATING 3.4 ALL CUTTING, PATCHING, EXCAVATING, BACK FILLING AND CONCRETE WORK 1.1 b CONDUCTORS LARGER THAN ABOVE,WHICH DO NOT HAVE CONTINUOUS EQUIPMENT SHALL NOT BE MORE THAN 5'-0"UNLESS THE WRITTEN APPROVAL FROM HANDLE. 2.11 PROVIDE (3) SPARE 1"CONDUITS INTO ACCESSIBLE CEILING SPACE WHERE PANELS RELATED TO THIS CONTRACT WILL BE THE RESPONSIBILITY OF THE ELECTRICAL INSULATION COLOR SHALL BE COLOR CODED BY APPLICATION OF AT LEAST TWO LAPS OF ARCHITECT OR ENGINEER IS OBTAINED. ARE FLUSH-MOUNTED. CONTRACTOR.THIS CONTRACTOR SHALL ASSUME THE RESPONSIBILITY OF PROVIDING THE COLORED TAPE ON EACH CONDUCTOR AT ALL POINTS OF ACCESS INCLUDING 1.2 SAFETY SWITCHES SHALL BE RATED FOR 240 OR 600 VOLTS AS APPLICABLE.THEY SLEEVES, CHASES AND OPENINGS NECESSARY FOR THE ELECTRICAL INSTALLATION AND JUNCTION BOXES.COLOR TAPE SHALL BE THE EQUAL OF 3M PRODUCTS SCOTCH #35. 2.0 PULL AND JUNCTION BOXES SHALL BE HORSEPOWER RATED WHEN USED IN MOTOR CIRCUITS. 3.0 DISTRIBUTION PANELS FOR THEIR REPAIR IN AN ACCEPTABLE MANNER,AS DETERMINED BY THE ARCHITECT.ALL HOLES SHALL BE CORE-DRILLED. PROVIDE FIRE STOP IN ALL OPENINGS CREATED THROUGH 1.1 c CONDUCTORS SHALL BE SOFT ANNEALED COPPER INSULATED FOR 600 VOLTS 2.1 INSTALL PULL AND JUNCTION BOXES WHERE SHOWN ON THE DRAWINGS,AND 1.3 SAFETY SWITCHES SHALL BE FUSIBLE OR NON-FUSIBLE 2,3 OR 4 POLE AS 3.1 ACCEPTABLE MANUFACTURERS:SQUARE D,CUTLER HAMMER,SEIMENS, G.E..FOR FIRE-RATED WALLS, FLOORS,OR CEILINGS. UNLESS SPECIFICALLY INDICATED OTHERWISE.ALUMINUM CONDUCTORS ARE NOT WHERE REQUIRED FOR CHANGES IN DIRECTION,AT JUNCTION POINTS,AND TO FACILITATE INDICATED ON THE DRAWINGS. PRICING AND ORDERING INFORMATION, PROVIDE EQUIPMENT AS SPECIFIED HEREIN, ALLOWED ON THIS PROJECT. WIRE PULLING. FURNISH BOX SIZES IN ACCORDANCE WITH NEC UNLESS LARGER BOXES ARE NO SUBSTITUTIONS PERMITTED.CONTRACTOR SHALL CONTACT NO LATER THAN 5 DAYS 3.5 THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL REQUIRED ACCESS INDICATED. 1.4 SAFETY SWITCHES SHALL BE SINGLE THROW UNLESS OTHERWISE INDICATED ON AFTER JOB IS AWARDED TO ENSURE LEAD TIMES DO NOT AFFECT PROJECT SCHEDULE . PANELS NECESSARY FOR HIS WORK, COORDINATE WITH ARCHITECT PRIOR TO 1.2 INSULATION TYPE SHALL BE TYPE THW FOR WIRE SIZES#8 AWG AND LARGER AND THE DRAWINGS. DISTRIBUTION PANELS SHALL BE DEAD FRONT TYPE WITH FEATURES AND RATING AS INSTALLATION. THHN OR THWN FOR #1 OAWG AND SMALLER.THHN SHALL NOT BE USED IN WET OR DAMP 2,2 PROVIDE STEEL BOXES AND REMOVABLE COVERS OF CODE GAGE, HOT ROLLED SCHEDULED ON THE DRAWINGS. LOCATIONS. SHEET STEEL, HOT DIPPED GALVANIZED INSIDE AND OUTSIDE, FOR ABOVE GROUND WORK. 1.5 ENCLOSURES SHALL BE NEMA 1 INDOORS AND NEMA 3R OUTDOORS UNLESS 4.0 MATERIALS AND WORKMANSHIP FURNISH WEATHERPROOF BOXES WHEN INSTALLED ABOVE GROUND OUTSIDE. OTHERWISE INDICATED ON THE DRAWINGS. 3.2 MOLDED CASE CIRCUIT BREAKERS SHALL BE AS SCHEDULED,OF SIZE AND NUMBER 1.3 PROVIDE WIRE AND RACEWAY SYSTEM AS DESCRIBED HEREIN AND AS INDICATED INDICATED ON THE DRAWINGS.ALL BREAKERS SHALL BE BOLT-ON TYPE. 4_1 ALL WORK SHALL BE INSTALLED IN A PRACTICAL WORKMANLIKE MANNER BY ON THE DRAWINGS.METAL-CLAD (MC.) ARMORED CABLE (AC)AND NON-METALLIC 2.3 PROVIDE CAST IRON BOXES, HOT DIPPED GALVANIZED INSIDE AND OUTSIDE WHERE 1.6 MANUFACTURER SHALL BE SQUARE D,SEIMENS OR CULTER-HAMMER. MECHANICS SKILLED IN THE SEVERAL TRADES NECESSARY SHEATHED CABLE (NMC) SHALL NOT BE PERMITTED UNLESS NOTED SPECIFICALLY SHOWN ON THE DRAWINGS. FURNISH REMOVABLE COVERS WITH GASKETS AND STAINLESS 3.3 ALL LUGS SHALL BE UL APPROVED CU/AL TYPE. OTHERWISE AND APPROVED PRIOR TO BIDDING. STEEL, BRASS OR BRONZE SCREWS. 1.7 MOUNT THE SAFETY SWITCHES SECURELY BETWEEN 3'X C LEVELS ABOVE THE - 4.2 ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECTS AND SHALL BE THE BEST OF FLOOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 3.4 PANELS SHALL BE MANUFACTURED AS A COMPLETE UNIT AND NOT AN ASSEMBLY OF THEIR SEVERAL KINDS UNLESS SPECIFIED OR INDICATED ON THE DRAWINGS TO THE 1.4 PROVIDE MINIMUM #12 CONDUCTORS, UNLESS OTHERWISE INDICATED. 2.4 PROVIDE CONCRETE BOXES FOR UNDERGROUND WORK UNLESS OTHERWISE PARTS SECURED FROM A SUPPLY HOUSE. CONTRARY. INDICATED ON THE DRAWINGS. FURNISH STEEL FRAMES AND COVERS WITH THE COVER 1.8 MOUNT THE SAFETY SWITCHES SECURELY BETWEEN SX& LEVELS ABOVE THE 1.4a CONTROL CONDUCTORS SHALL BE #14 MINIMUM FOR N.E.C.CLASS 1 AND #16 ATTACHED TO THE FRAME WITH HEXAGON HEAD, BRASS OR BRONZE CAP SCREWS,3/8"IN FLOOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 3.5 ALL PANELS SHALL BE CAPABLE OF ACCEPTING CIRCUIT BREAKERS SIZED UP TO AND 4`3 DURING EACH PHASE AND AT THE COMPLETION OF THE CONSTRUCTION,THIS FOR N.E.C.CLASS 2. DIAMETER. PROVIDE A RUBBER GASKET FOR SEALING BETWEEN THE COVER AND THE INCLUDING 400 AMPS. CONTRACTOR SHALL REMOVE ALL DEBRIS AND EXCESS MATERIALS CAUSED BY HIS WORK. FRAME. PAINT THE COVER WITH TWO COATS OF HEAVY ASPHALTUM. 1.9 SWITCHES ON BLOCK WALLS SHALL BE MOUNTED ON A 3/4" PLYWOOD HE SHALL LEAVE THE AREA OF OPERATION BROOM CLEAN. 1.5 CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED. BACKBOARD,WHERE LOCATED INDOORS. 3.6 VERTICAL BUSSING SHALL BE EXTENDED THE FULL LENGTH OF THE PANEL. CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLD 3.0 OUTLET BOXES DIVISION 16420 - MOTOR STARTERS 05-02-13 ISSUE FOR LANDLORD & PERMIT 4.4 ALL ELECTRICAL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL l.6_ 3.7 ALL BUS BARS SHALL BE RECTANGULAR SOLID COPPER. OR ETL LABEL. 3.1 USE SHEET STEEL BOXES,ZINC COATED OR CADMIUM PLATED, FOR CONCEALED 1.7 INSTALL ALL WIRING IN CONDUIT. INTERIOR WORK. 1.0 MOTOR STARTERS 3;8 DISTRIBUTION PANELS SHALL BE SQUARE D. 04-19-13 PRELIM PACKAGE ISSUE 4.5 THIS CONTRACTOR SHALL GUARANTEE HIS WORKMANSHIP AND MATERIAL (LAMPS - EXCEPTED) FOR A PERIOD OF ONE YEAR FROM THE DATE OF BUILDING OPENING AND 1.8 CONNECT#10 AND SMALLER WIRES WITH CONSTANT PRESSURE EXPANDABLE 3.2 USE CAST BOXES,ZINC-CADMIUM FINISH MALLEABLE IRON,FOR EXPOSED INTERIOR 1.1 PROVIDE MOTOR STARTERS (MAGNETIC OR FUSED COMBINATION)AND 3.9 INSTALL PANELS SUCH THAT HANDLE FOR THE TOP BREAKER DOES NOT EXCEED 6-6" A DATE REVISIONS LEAVE HIS WORK IN PERFECT ORDER AT THE COMPLETION.SHOULD DEFECTS DEVELOP SPRING TYPE CONNECTORS,"SCOTCHLOK"BY 3M OR B-CAP BY BUCHANAN. WORK,AND FOR EXPOSED OR CONCEALED WORK IN WET, DAMP OR EXTERIOR CONTROL EQUIPMENT WHERE SHOWN.STARTERS SHALL BE PROVIDED WITH 120 VOLT ABOVE FINISHED FLOOR. WITHIN THE GUARANTEE PERIOD, THE CONTRACTOR SHALL, UPON NOTICE OF THE LOCATIONS.CAST BOXES SHALL BE SERIES FD BY CROUSE HINDS OR APPLETON. COILS,3 OVERLOADS, CONTROL TRANSFORMER WITH FUSED 120 VOLT SECONDARY KEY PLAN: SAME, REMEDY THE DEFECTS AND HAVE ALL DAMAGES TO OTHER WORK OR FURNISHINGS 1.9 CONNECT#8 AND LARGER WIRES WITH COMPRESSION CONNECTORS OR CONTROL CIRCUIT, 2 N.O.AND 2 N.C.AUXILIARY CONTACTS, HAND-OFF-AUTO BE O O 3.10 PROVIDE PHENOLIC LABELS FOR EACH PANEL. ..,�yyi': �`�Y��i►i�}. ;: Fl.y�%�yyy�k$,�� '`..y�srS�,���r`y �s,jis�cni/y�./,a7^� y. ���;,'. CAUSED BY THE REPAIRS CORRECTED AT HIS EXPENSE TO THE CONDITION BEFORE SU H SPLICES AS MANUFACTURED BYBUR DY OR &B. 3.3 WALL BOX SIZES (MINIMUM) SHALL BE 4 SQUARE X 2_1/2 DEEP WHERE WALL SELECTORSWITCH AND RUNNING PILOT LIGHT, UNLESS OTHERWISE NOTED.WIRE THRUy;DAMAGE. CONTROL DEVICES FURNISHED BY OTHER TRADES.SINCE MOTOR DRIVEN EQUIPMENT CONSTRUCTION PERMITS.WHERE WALL CONSTRUCTION DICTATES, THE WIDTH MAY BE 3.11 ALL BOLTED CONNECTIONS SHALL BE TORQUED IN ACCORDANCE WITH IS FURNISHED BY OTHER TRADES,THE CONTROL INDICATED ON THE DRAWINGS SHALL MEN 1.10 INSULATE SPLICING CONNECTORS TO AT LEAST 200%OF THE WIRE REDUCED TO2-1/8, OR 1-1 2, UNDER SPECIAL CONDITIONS. MANUFACTURERS STANDARDS. v' -.; , � BE CONSIDERED AS FOR BIDDING PURPOSES ONLY.WIRE TO CONFORM TO THE o 5.0 SCOPE OF WORK INSULATION. USE PRE-STRETCHED TUBING CONNECTOR INSULATORS. 3M PST FOR #2 AND ACTUAL EQUIPMENT SUPPLIED AND INSTALLED BY THE OTHER TRADES.ALL FUSES '; �"g `f LARGER CONDUCTORS. 3.12 SURFACE-MOUNTED PANELS SHALL BE MOUNTED ON A 3/4 PLYWOOD ` '' 3.4 FIXTURE OUTLETS IN CEILINGS (MINIMUM) SHALL BE 4 OCTAGONAL X 1-1/2 DEEP SHALL BE DUAL ELEMENT TYPE. PROVIDE BLOWN FUSE INDICATOR LAMPS IN COVER. 5.1 THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL, - ' 4-11/16 OCTAGONAL X 2-1/2 DEEP WHERE REQUIRED TO ACCOMMODATE LARGER BACKBOARD. FLOOR-MOUNTED PANELS SHALL BE MOUNTED ON A 4 HIGH CONCRETE I STORAGE, UNPACKING AND PLACEMENT;TO INCLUDE BUT NOT BE LIMITED TO,THE 1.11 PULL CONDUCTORS USING RECOGNIZED METHODS AND EQUIPMENT LEAVING AS ( PAD. y ,� J ( FOLLOWING ITEM: CONDUIT OR LARGER NUMBER OF WIRES). 1.2 STARTERS SHALL BE SQUARE D,SEIMENS OR CUTLER-HAMMER. _: �> yj �,a N LEAST 6"WIRE AT ALL JUNCTION BOXES FOR CONNECTIONS. - 3.5 GANG BOXES SHALL BE ONE PIECE (MINIMUM),2-1/8"DEEP. 1.3 THE EXACT NUMBER OF NORMALLY OPEN AND NORMALLY CLOSED AUXILIARY 5.1a EMERGENCY LIGHTING AND POWER 1.112 CLEAN OUT EACH CONDUIT SYSTEM BEFORE PULLING WIRE. - CONTACTS IN EACH STARTER SHALL BE DETERMINED BY THE TEMPERATURE CONTROL . IF� ,�,y 3.6 PROVIDE FLUSH FLOOR BOX SERIES 880 BY WIRE MOLD WITH DUPLEX RECEPTACLE AND/OR FIRE ALARM CONTRACTOR. g£ yor�as�ror ;' ;f DIVISION 16451 DRY TYPE TRANSFORMERS - £E� f 3 5.1 b COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEM INCLUDING ALL 1.12 FORM AND TIE ALL WIRING IN PANEL BOARDS. - FOR WOOD PLATFORM AT DISPLAY SHOW WINDOWS,BOX WITH COVER PLATE FLANGE: ° r %f TRANSFORMERS AND FEEDERS 1.4 COORDINATE ALL EQUIPMENT INDICATED ON THE ELECTRICAL DRAWINGS WITH CAT. #880W1-817TCAL AND BRUSHED ALUMINUM COVER PLATE:CAT. #828R-TCAL WITH MECHANICAL EQUIPMENT SCHEDULES AND SPECIFICATIONS AND PROVIDE MOTOR 1.13 THERE SHALL BE NO WIRE NUT JOINTS OR SPLICES MADE INSIDE SWITCHBOARDS/ FLIP LID TO PROTECT RECEPTACLE WHEN NOT IN USE. BOTH FLANGE AND COVER PLATE 1.0 TRANSFORMERS L'OCCITANE 5.1c COMPLETE BRANCH CIRCUIT WIRING SYSTEM. PANEL BOARDS. SHALL HAVE BRUSHED ALUMINUM FINISH. UL SCRUB LISTED. STARTERS FOR ALL EQUIPMENT INDICATED AS BEING INTERLOCKED OR STARTED FROM A REMOTE LOCATION. SPACE #H6 5.1 d COMPLETE POWER WIRING FOR ALL AIR CONDITIONING EQUIPMENT, PLUMBING 1.1 TRANSFORMERS SHALL BE CONTINUOUSLY RATED ISOLATING TYPE FOR 60 HERTZ 1.14 BRANCH CIRCUIT WIRE SIZES (AND CONDUITS)SHALL BE INCREASED FROM THOSE 3.7 FLUSH MOUNT BOXES IN ALL FINISHED WALLS, INSTALL THE PLASTER RINGS IN DRY 1,5 STARTERS SUPPLIED AS AN INTEGRAL PART OF EQUIPMENT SHALL BE FURNISHED SERVICE UNLESS OTHERWISE INDICATED. LOCATION: SYSTEM, HEATING EQUIPMENT, VENTILATING AND EXHAUST EQUIPMENT. INDICATED ON THE PLANS TO PREVENT EXCESSIVE VOLTAGE DROP.BRANCH CIRCUITS WALLED PLASTERED WALLS AND RAISED COVERS AS REQUIRED IN WALLS WITH OTHER UNDER THE DIVISION PROVIDING THE EQUIPMENT.WIRING AND DISCONNECT SHALL SHALL BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE FINISHES SO THAT THE COVER PLATES FIT TIGHTLY AGAINST BOXES OR RINGS.3/16" BE BY THIS CONTRACTOR.ALL OTHER STARTERS AND AUXILIARY CONTROL EQUIPMENT 1.2 INSULATION SYSTEMS SHALL BE 220 DEGREES C (150 DEGREES RISE). 5.1 e COMPLETE LIGHTING FIXTURE INSTALLATION, INCLUDING ALL INCANDESCENT, PANEL AND THE LOADS DOES NOT EXCEED LIMIT OF 35. MAXIMUM GAPS ARE ALLOWED FOR NONCOMBUSTIBLE WALLS. SHALL BE SUPPLIED AND WIRED BY THIS CONTRACTOR UNLESS OTHERWISE NOTED. FLUORESCENT AND HID LAMPS. 1.3 ENCLOSURES FOR TRANSFORMERS SHALL BE METALLIC,SUITABLE FOR INDOOR AND L' OCCITAN 1.15 WIRE SIZES SHALL BE BASED ON THE 60°C.AMPACITIES FOR WIRE SIZES NO. 14-1 , 3.8 ADJUST LOCATION OF OUTLETS IN MASONRY OR TILE CONSTRUCTION TO OCCUR IN OUTDOOR INSTALLATION AS APPLICABLE AND RODENT PROOF. 5.1 f COMPLETE COMMUNICATIONS CONDUIT AND WIRING SYSTEM INCLUDING BOXES, A.W.G.,AND 75°C.AMPACITIES FOR WIRE SIZES #1/0 A.W.G.AND LARGER. THE NEAREST JOINT TO THE HEIGHT SPECIFIED. HEIGHTS SHALL MEET A.D.A. REQUIREMENTS. EN PROVENCE PLATES, JACKS, ETC.,AS SPECIFIED,SHOWN ON THE DRAWINGS AND REQUIRED BY THE 1.4 MANUFACTURERS SHALL BE SQUARE D. FRACTIONAL KVA TRANSFORMERS SHALL BE TENANT. 1.16 CIRCUITS MAYBE MULTI-PLEXED IN CONDUIT PROVIDED WIRE IS PROPERLY DERATED 3.9 SUPPORT ALL BOXES TO MAINTAIN PROPER ALIGNMENT AND RIGIDITY. DIVISION 16442 - DISTRIBUTION AND PANELBOARDS MANUFACTURED BY EDWARDS OR THE SPECIAL EQUIPMENT MANUFACTURER IN WHICH BOUTIQUE #057 AND CONDUIT SIZED PER CODE. UNDER NO CIRCUMSTANCES SHALL MORE THAN (9) THE TRANSFORMERS ARE USED. WASHINGTON SQUARE MALL 5.11 TEMPORARY ELECTRICAL POWER AND LIGHTING AS REQUIRED FOR CONSTRUCTION. CURRENT CARRYING CONDUCTORS BE RUN IN A SINGLE CONDUIT. 3.10 CLEAN BOXES OF ALL FOREIGN MATTER PRIOR TO THE INSTALLATION OR WIRING OR DEVICES. 1.0 LIGHTING CONTROL SYSTEM 1.5 FOUR APPROVED VIBRATION DAMPENERS PER TRANSFORMER SHALL BE EMPLOYED SPACE #H6 5.1 h TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. 1.17 PROVIDE WIRE AND RACEWAY SYSTEMS AS DESCRIBED HEREIN AND INDICATED ON AS NECESSARY TO AVOID TRANSMITTING ANY VIBRATION TO THE BUILDING STRUCTURE. DRAWINGS. METAL-CLAD MC) ARMORED CABLE AC) AND NON-METALLIC SHEATED 1.1 GENERAL INTRODUCTION:THE WORK COVERED IN THIS SECTION IS 9555 SW WASHINGTON SQ. RD. 3.11 MOUNTING HEIGHTS ON THE DRAWINGS ARE TO THE CENTERLINE OF THE BOX SUBJECT TO ALL THE REQUIREMENTS IN THE GENERAL CONDITIONS OF THE SIZES OF THE MOUNTINGS SHALL BE SELECTED ON THE BASIS OF THE WEIGHT OF THE 5.1 i EXIT LIGHT SYSTEM. CABLE (NMC) SHALL NOT BE PERMITTED, UNLESS NOTED SPECIFICALLY OTHERWISE AND UNLESS OTHERWISE NOTED. TRANSFORMER, USING: TIGARD, OR 97223 APPROVED PRIOR TO BIDDING. SPECIFICATIONS.THE CONTRACTOR SHALL COORDINATE ALL OF THE WORK IN THIS 5_1 j.WIRING DEVICES AND FLOOR BOXES. SECTION WITH ALL OF THE TRADES COVERED IN OTHER SECTIONS OF THE 621 SF SPECIFICATION TO PROVIDE A COMPLETE AND OPERABLE SYSTEM. 1.5a A MINIMUM 1"THICK RUBBER-CORK-RUBBER SANDWICH TYPE FOR FLOOR MOUNTING. AREA: 5.1k LIGHTING CONTROLS. DIVISION 16130 - RACEWAYS AND BOXES DIVISION 15140 - WIRING DEVICES 1.2 DESCRIPTION OF THE WORK: 1.5b A SPRING TYPE FOR SUSPENSION MOUNTING. SHEET TITLE: 5.11 GROUNDING OF THE ELECTRICAL SYSTEM. 1.5c TWO(2) SPRING TYPE AT THE TOP (WITH TWO (2) STEEL BRACKETS)AND TWO 1.0 RACEWAYS 1.0 WIRING DEVICES 1.22 THE EXTENT OF THE LIGHTING CONTROL SYSTEM WORK IS INDICATED BY THE (2) ELECTRICAL 5.1 m FIRE SUPERVISORY ALARM SYSTEM. DRAWINGS AND BY THE REQUIREMENTS OF THIS SECTION. IT IS DEFINED TO INCLUDE, RUBBER-IN COMPRESSION TYPE AT THE BOTTOM (STAND-OFF) FOR WALL MOUNTING. 1.1 ALL WIRE SHALL BE RUN IN ACCORDANCE WITH CODE IN CORROSION RESISTANT, 1.1 WIRING DEVICE COLOR SHALL BE WHITE,UNLESS OTHERWISE NOTED. BUT NOT BY WAY OF LIMITATION: 1_6 NO CONDUITS SHALL BE ATTACHED DIRECTLY TO THE TRANSFORMER.AT EACH SPECIFICATIONS RIGID,THREADED, METAL CONDUIT OR ELECTRICAL METALLIC TUBING (E.M.T.) UNLESS 5.1 n TELEPHONE AND ELECTRIC SERVICES OTHERWISE SPECIFICALLY STATED HEREIN. 1.2 PROVIDE TOTALLY ENCLOSED,20 AMPERE, 120/277 VOLT,QUIET A/C GENERAL 1.2a 1 PANELBOARDS CONTAINING INTEGRAL CONTACTORS. ATTACHMENT, PROVIDE A VIBRATION DAMPENING ASSEMBLY CONSISTING OF: 5.10 SOUND SYSTEM COMPONENTS, CONDUIT SYSTEM &WIRING USE SNAP SWITCHES. 1.1a CONDUIT IN EXTERIOR WALLS, BELOW FLOOR SLAB,OR UNDERGROUND SHALL BE 1.2a2 CONTROL ELECTRONICS FOR CONTACTORS AND 1.6a AT&B #5721,2,3 ETC., OR EQUIVALENT FEMALE HUB TYPE LIQUID-TIGHT CONNECTOR 5.1 p COMPLETE CONDUIT SYSTEM FOR SECURITY DEVICES, INCLUDING PULL STRING. RIGID THREADED, GALVANIZED, HEAVY WALL TYPE. 1.3 SWITCHES SHALL BE SPECIFICATION GRADE AS MANUFACTURED BE HUBBELL, TIMECLOCKS AND MONITORING THE STATUS OF THE SYSTEM. BY STEEL CITY, EFCOR OR APPROVED EQUAL. PROJECT NO. 13-1802 P&S, OR LEVITON. 1.1b CARLON PVC TYPE 40 HEAVY WALL CONDUIT WITH GROUND WIRE MAY BE USED 1.2a3 ASSOCIATED LOW AND LINE VOLTAGE OVERRIDE SWITCHES AND LIGHT 1.6b T&B #5331,2, 3 ETC., OR EQUIVALENT MALE HUB TYPE LIQUID-TIGHT CONNECTOR SCALE: 1/4 If = 1'-0" BELOW FLOOR SLAB OR UNDERGROUND IN LIEU SHALL NOT BE RUN IN OR ABOVE 1.4 PROVIDE NEMA CONFIGURATION 5-20R DUPLEX 125 VOLT GROUNDING TYPE SENSORS. WITH AN INSULATED THROAT BY STEEL CITY,EFCOR OR APPROVED EQUAL. FLOOR SLAB. PVC CONDUIT SHALL TERMINATE BELOW FLOOR SLAB WITH RIGID,THREADED RECEPTACLES RATED FOR 20 AMPERES UNLESS OTHERWISE INDICATED ON THE DATE: 04/17/13 METAL CONDUIT ADAPTER.CONDUIT ABOVE SLAB SHALL BE METAL. DRAWINGS. 1.2a4 TIMECLOCKS, CONTACTORS. 1.6c SHORT LENGTH (24"PLUS OR MINUS) OF LIQUID-TIGHT FLEXIBLE CONDUIT. 1.1c CONDUIT RUN EXPOSED TO THE WEATHER SHALL BE HEAVY WALL,METAL THREADED 1.5 RECEPTACLES SHALL BE SPECIFICATION GRADE AS MANUFACTURED BY HUBBELL, 1.2a5 ANY WORK STATIONS,SOFTWARE AND COMMUNICATIONS HARDWARE. 1.6d A BONDING JUMPER OF NEC SIZE OUTSIDE OF THE ASSEMBLY. DRAWN BY: KJ TYPE. P&S OR LEVITON. 1.2b SYSTEM INSTALLATION INCLUDES THE FOLLOWING: REVIEWED BY: BB 1.2b1 WIRING OF BRANCH CIRCUIT CONDUCTORS AND CONTACTORS SHEET NO. MECHANICAL SPECIFICATIONS 1 NTS enneth ar Architecture Urban Planning Store Design 360 Mixed-Use New LYork,NY 10017 exington Avenue Z Retail Development www.kennethpark.com I MEP Consultant 101 STOCK ROOM 100 SALES AREA 12'-0" ACT 11'-0" GWB-Pb I don penn a consulting engineer j 635 Westport Parkway Suite 300 I Grapevine,Texas 76051 Phone:817-410-2858 Fax:817-251-8411 I SEAL: —1 1++01 -- I s 0CC m Op z III ® ® y O O O O O O O ® � � `� w CM -- — — — — -- ---- -- -- — --- -- — — -I -- - — -- yd ,.♦ Q 5 I -- 40.5 O O y o i J I O O ® o li O O O O O O I O O O O I t I .. Z ..m.- ..-.- v......- ....® v....rs ' w....- .......v. ...-® 1 t 9'-11" GWB-P1 NOTE:SPRINKLER SYSTEM 12'-0" GWB-Pb 8'-10" GWB-Pb GC TO MAINTAIN A VIABLE AUTOMATIC SPRINKLER 05-02-13 ISSUE FOR LANDLORD & PERMIT SYSTEM DURING CONSTRUCTION.GC TO COORDINATE O4-1 9-13 PRELIM PACKAGE ISSUE DESIGN, PLAN CHECK AND MODIFICATION OF EXISTING FIRE SPRINKLER SYSTEM WITH LANDLORD'S DESIGNATED FIRE SPRINKLER CONTRACTOR. DATE REVISIONS ALL OF TENANT'S FIRE PROTECTION SYSTEM WILL BE DESIGNED AND INSTALLED BY LANDLORD'S FIRE KEY PLAN. PROTECTION CONTRACTOR. TENANT'S G.C.IS Q f i r lr REQUIRED TO USE L.L.'S CONTRACTORS AT TENANT G.C.'S EXPENSE,G.C.TO COORDINATE WITH MALL OPERATIONS DIRECTOR. ALL SPRINKLER SHOP DRAWINGS AND PERMITS SHALL BE 'e . R � PROVIDED BY GC.SHOP DRAWINGS WILL BE SUBMITTEDY3 FOR ALL FIRE PROTECTION SYSTEMS. SHOP DRAWINGS MUST BE SUBMITTED TO LL REVIEW AND APPROVAL. u r x /y g sad s9 r "` f f�:.. 4 ,. 9 ..... � yds NOIRDS FIRE PROTECTION PLAN 1 �I „ — � L'OCCITANE 1/4 — 1 -0 SPACE #H6 LOCATION: SYMBOL DESCRIPTION 16"MAX SEISMIC BRACE ROOF BEAMS UPRIGHT SPRINKLER HEAD MAXIMUM DISTANCE GOOSENECK (WHERE REQUIRED) f ABOVE BEAM SEMI-RECESSED SPRINKLER HEAD L' OCCI (SEE TABLE) EN PROVENCE ® DISTANCE TO BEAM SPRINKLER HEAD BOUTIQUE #057 OO CONCEALED SPRINKLER HEAD \-CLEVIS HANGER SPRINKLER BRANCH WASHINGTON SQUARE MALL (RISER NIPPLE CONCEALED SPRINKLER HEAD SPACE #H6 RE EXISTING SPRINKLER HEAD TO BE RELOCATED. � 9585 SW WASHINGTON SQ. RD. 6_,____SPRINKLER BRANCH TIGARD, OR 97223 N PROVIDE&INSTALL NEW SPRINKLER HEADFUSIBLE JOINT SPRINKLERS TO BE LOCATED IN DISTANCE FROM SPRINKLER MAXIMUM ALLOWABLE DISTANCE CENTER OF 2'X 2'CEILING TILES. CEILING PLATE AREA: 621 SF T.G.C.TO MODIFY AND ADJUST EXIST SPRINKLER HEADS AS REQUIRED FOR NEW LAYOUT& TO SIDE OF BEAM DEFLECTOR ABOVE (WHERE APPLICABLE) CEILING HEIGHTS-TYPICAL BOTTOM OF BEAM SHEET TITLE: LESS THAN 1 FT 0IN. CONCEALED SPRINKLER INSTALLATION 1 FT TO LESS THAN 2 FT 1 IN. NO SCALE FIRE PROTECTION PR I N K L E RSYMBOLS q, 2 FT TO LESS THAN 2 FT 6 IN 2 IN.S 2 FT 6 IN TO LESS THAN 3 FT 3 IN. 3 FT TO LESS THAN 3 FT 6 IN 4 IN. SEISMIC BRACE PLAN 3 FT 6 IN TO LESS THAN 4 FT 6 IN. GOOSENECK (WHERE REQUIRED) ROOF BEAMS 4 FT TO LESS THAN 4 FT 6 IN 7 IN. 4 FT 6 IN TO LESS THAN 5 FT 9 IN. 5 FT SFT 601NLESS THAN 5 FT 6 IN 11 T0 LESS THAN 6 FT 14(N: PROJECT N0. 1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL FEDERAL,STATE AND LOCAL CODES AND ORDINANCES. 13-1802 2. ALL DRAINAGE PIPING 4"AND LARGER SHALL BE SLOPED AT 1/8"PER FOOT MINIMUM. 3. ALL DRAINAGE PIPING 3"AND SMALLER SHALL BE SLOPED AT 1/4"PER FOOT MINIMUM. UPRIGHT SPRINKLER INSTALLATION SPRINKLER BRANCH SCALE: 1/4" = 1'-0" 4. REFER TO ARCH. REFLECTED CEILING PLANS FOR LIGHT FIXTURE,SPEAKER, DIFFUSER, ETC.LOCATIONS. NO SCALE �CLEVIS HANGER RECESSED SPRINKLER 5. SPRINKLER PIPING SHALL BE ROUTED TO AVOID CONFLICTS WITH NEW AND EXISTING DUCTWORK, PIPING CONDUITS AND DATE: 04/17/13 LIGHTING LAYOUT. 6. SPRINKLER CONTRACTOR SHALL OBTAIN DUCTWORK SHOP DRAWING FROM HVAC CONTRACTOR AND COORDINATE ROUTING DRAWN BY: KJ OF SPRINKLER PIPING. ANY RELOCATION REQUIRED BY SPRINKLER CONTRACTORS FAILURE TO COORDINATE SHALL BE DONE AT SPRINKLERS TO BE LOCATED IN NO EXTRA COST OR DELAY TO THE OWNER. GENERAL CONTRACTOR TO COORDINATE. CENTER OF 2'X 2'CEILING TILES. 7. FINAL CONSTRUCTION DOCUMENTS, HYDRAULIC CALCULATIONS AND PERMITTING SHALL BE BY THE SPRINKLER CONTRACTOR. RECESSED SPRINKLER INSTALLATION REVIEWED BY: BB 8. NSTALL INSPECTOR TEST CONNECTIONS PIPED TO FUNNEL DRAIN. 9. TENANT'S G.C.SHALL EMPLOY LANDLORDS FIRE SRINKLER CONTRACTOR TO MAKE ANY MODIFICATIONS TO THE EXISTING NO SCALE SHEET NO. SPRINKLER SYSTEM. FIRE ALARM SYSTEM 5 SPRINKLER NOTES 3 SPRINKLER DETAILS 2 NTS NTS NTS