Plans ELC2013 - 00176 GENERAL LIGHTING NOTES } 1. EXIT SIGN MOUNTING A WALL FIXTURE: CENTER 12" ABOVE DOOR OPENING. E „ ( B. CEILING/PENDANT FIXTURE: ON CEILING OR BUILD G � AT HEIGHT SPECIFIED ON DRAWINGS. C. THE USE OF TRITIUM BASED RADIOACTIVE EXIT SIGNAGE SHALL NOT BE ALLOWED. 2. EMERGENCY LIGHT INSTALLATION FIXTURE MOUNTING A. WALL FIXTURE: 12" BELOW FINISHED CEILING OR +10'-"0" IN AREAS OF EXPOSED STRUCTURE, UNLESS NOTED OTHERWISE. B. PENDANT FIXTURE: BOTTOM CHORD OF BAR JOIST OR AT HEIGHT SPECIFIED ON DRAWINGS. C. REMOTE HEAD FIXTURE: HEADS CENTERED ABOVE DOOR OPENING +9'-0", UNLESS NOTED OTHERWISE AND BATTERY PACK0ZQ � oa~ QZZWp 1 2 3 3.4 4 4.5 5 5.5 6 6.5 7 7.5 8 9 MOUNTED ON INTERIOR SIDE OF WALL 12 w 0 p dQo�� t d r r BELOW FINISHED CEILING OR AT BAR JOIST �� aZ�oa,;;�v,a�0 a IN AREAS OF EXPOSED STRUCTURE, a`;>.No�mmoamwoww t i 3 ELECTRICAL CONNECTION o a�No���WW�Z�Q� ELECT C CO NEC � �-Ho�oH� awZ��Q dd } I } I A. REFER TO MANUFACTURER'S WRITTEN g0z v o�- �� � ¢ NWW�pO�p I � Z Q�ZOOW UO a i I INSTRUCTIONS. ALLOW BATTERY TO CHARGE ��o o�0o�oaazza 3 I CONTINUOUSLY FOR A MINIMUM OF 168 J a HQ�w6KOf2p:?Q HOURS BEFORE INITIAL TESTING. Q k Q�-z�ir.Wcno=) ^-' B. AFTER EMERGENCY LIGHT HAS BEEN a. I Z) ozzODW WWWHO crW I I I I 3 I POWERED DO NOT TURN OFF FOR EXTENDED V) -D 'DZoavW,aWW¢lo- PERIODS OF TIME. 3. EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT ► 1 a n LIGHTS SHALL NOT BE SWITCHED. "Z)N1 } 4. IN AREAS OF OPEN STRUCTURE, MOUNT ®� o FLUORESCENT STRIP FIXTURE TO BOTTOM } I I I 3 CHORD OF BAR JOIST, UNLESS NOTED �� } 9 i G� M r _ } +10f-0,f TYP, UNLESS NOTEDi OTHERWISE. OTHERWISE. W■�p ��� `' I ' I 11 DO NOT INSTALL FIXTURE ACROSS CMU 5. PROVIDE SEPARATE BOXES FOR GANGED ® � } 3 1 I H1 P1 , W`� Ir.- o t I I , CONTF 01_ JOINT OR IN DOOR LINTEL 1 I SWITCHES ON SEPARATE BRANCH CIRCUITS. V_ ZO ;!o } +16'-0„ 5W 4 2 t 1 1 6• FIXTURES DENOTED WITH "ABJ" ARE TO BE ¢ �z 00 = M E1.1 } _~~ j 2 FASTENED ON UNISTRUT CHANNELS MOUNTED �� M 46 N E1.1 � qq 1 TO THE BOTTOM SIDE OF THE TOP CHORD OF ., a_._. 1_ BAR JOISTS. LOCATE THE FIXTURES RUNNING z �- . .w., _. ..,. _ ,,.w.,,,..�,.:... �.....,. W.. w.,...,,.,,..w,.W, ,..�..»..,, ..,. ».w,m,..n...... ...._.,..tr, .... ,...,,.,�•H..�.ra .,, .,....,., .. :� _�_, 1_, ,.,.. _»_,w». ....w,._," w .�.....,...: ... ...... _fit~,. ,_.,,._ ._w _., _.,�-. „1 _,._.�. .., ..., ..,,.�,.«:>,..,. .,...„a ......, »:�,� :aa.�, .,� .,. ,,., ...:eu ����"'� 1 P � ��-� :�� � e�, PERPENDICULAR TO BAR JOISTS WITHIN � (PART. 1/2)H 1 t ` JOISTS WEBBING SPACES. DO NOT FASTEN EDC1 3 REF 4-E1.1 6 ABJ I tia { �''�\ Ii FIXTURE OR UNISTRUT CHANNELS TO ROOF +10'-6" I , x�:.j _ H1 P1 .._ A ,� ► DECK. I 7. ALIGN N TI R ROWS OF LIGHTS ON SALES I � h ABJ ABJ `ABJ ABJ ABJ ABJ ABJ ( �,� ' � 3 r��m � RECEIVING � 1 I � € �°° � �-- � 3ENTIRE G r N ABJ ' 3. ,x ` 1 "' - ABJ3 �° '`�� FLOOR TO AVOID CONFLICTS WITH STRUCTURAL pi Iyy I ABJ ABTYP x' i ^y'�`' BRIDGING. THE ENTIRE ROW SHALL NOT DEVIATE Ir 1 L L E R e M I M. k � .._..,.. rte.. „_„!. I ! ^ ELI ,Y4 '� •� ' I?d::,NK \�� 1 x _w- _•_ ;, 1 r , ' �. I MORE THAN 6" IN EITHER DIRECTION FROM ir4 i � 1 , � ui La�. ni stn 3a ,....� Lax^6 .. p,.q r }�rt�•-. �5ry e .}t� F�&I rtbwa.: S`__.•'h aC_.,� eWw, t TYP OF 4 12 I ABJ A A J _ �,�. (:v� ,x -r �_" ::,' f y' *, ., � I ti`�!S Oti Ri �D �N D1 L Rr v+ m 4""D �, t Y DIM IEi i i! 1 1vTC (1 1 DA I C.. 3 9mtia,swaarh i t I I BU1 BJ AB 12 -- " �E: k I' • > +a �A t { ? +s """VI Iri T�_" 1 � L_...� 8. INSTALL FURNISHED PROTECT-A-LAMP COVERS I ABJ I bI � I "•_ �Ir � � + }.I ►� � „ w >- 1 TYP OF RECEIVINGI I►� �I a , as �. a =�t ,I_ , r . ON FIXTURES LABELED WITH THE LETTER P . 0 ,tip' ' 2 � +10 -6 d- � � _ � ABJ ? r I � _ ,� �,r��a I� .�'� � t'��- t t ��-'' �: _"i;"`� eR���r �:�� � t i 1I� t tk "" r' � Ej ` # r pQIP "fu ¢i > ►�:�"i ".,,, - ''' i 3•; IS " raa ��•'''••' i ,._ i " r '6F,r ABJ } r �% �».,n r , f3 r fat SSE 1 'n I t I ABJ �-, a ¢ _:_ �». �_.,� �x.._D{ dL' ;;GE1 ly Y ABJ ' ABJ , I ABJ ABJ ABJ I I IIt ,., I t � , I L i {t sa• prL ¢'i.t a a% es asrta 1 3 i .d_, M',a OCCUPANCY'� 1 N{ P+a F �..„ C 4:" } i 'Sud+� Y rf '^"-'t. �r^^-� r � r%i } YP OF ROW y I. � a., ,,..,....!..,_. .C'.,_.-..,".w� ,� �t_,.o A{�J ��°,'„^.,, i { a' j,�daE.y1'._i t'H;aJ:i r } itr•:'.t 1} k� 1:. •«e >� s..........� �;__..+ e f o [ :.:,,......,..,... _.._=:'7:;.�..,., wI 4 o H P i � .,, a =' +-�-t•, ----e4 zs^., t y r 2 . It .... .. ... ,._ � L J• I �t •..., ..,m»......,.,._ ._....._,-,....,.. ... r+_.,,....,.r...e.. ,w.w_..,.r«n..nv. .,,-. n.nnw a{w,..,.:.n..,,. ,.,r nw.o+w.»,•w, .,w w..,w,.... rr...v...:»n....... :w,...,. w:.- .w..e....-,,... ._f...,.., V �����Iff��� .� n{ t�-rN N:ai I H.,,:.5i ,1'.«._•:_{ t 1•J C.; { Y. a:u L/�r�J kyr i r•1' .•,.re--�, e a .7: - {i t,r-V P�9 � ! f M 1 f `E• "..n.It 4 dt'.r' d C S.a h ,.v r i` 3 r s' 3 3 y 20 16.026 t s, ,;,i , t, a 4' ? f cr _ tI v a .. ................,.. ,. ,:: , �„i".....r.+�i. .r.w'ns+rrrlt'.arr•..i... h.raa■1.•'..r.ro:€t.i�;...rt ,.:,�^ ,.r... _ _.,n.,..w !1. ,.,«1.,. .. ...,',+ ... ....W_..: -_.. �3._ �: _ ,. , .,. .. '`L . .�,. ..,. .., n .. .. ,. ,�>r' "4.�I14... n .. ,. r� •t!y d,» _� ....- -. ..,�_",:»,..,w.w.. <h: M..d,_r+....., ., .,,!•` ,,n_ aka: .U�a... ..,.. ,.r. _. �, .. --OH NOTES I ; _✓ -_. ---_ _--- -- }' 35 35 A 4 <= 0 Eg 2 1. OCCUPANCY SENSORS IN MEN'S AND z a.t.,ra yrs,.rr i...,s^..+�- rr.r..rvrrr v.rr�F•..ww;wwwur+wrr rrrwww�►ww.I.rvn..i wrr�+•�+■.,w�.ter,w.�e:v�..wa.�.ur...w�rxw4 ww.rw,.rs,ww:..r+ •�.es d 4 «.,....+w..w,wr ,.. nr.-....,.:+,_+, w...ww..,._...�wr, r»..........,,.:w.w„ .w.,..w...r•w„_, w.,+.n -�a>:w'Skdh.uwwa4i.Y�n»iw'G»::W6Yv+wwliiClAb '. .:w7�ru � _ W,n..:. .. ,..-,,,..,: , �AIOI�r J ' � r '�..:I.ti.WavrL'Siw':i..:i6Twww+SR'M4:w .... M� •.¢ µ �; `�_' r I "` ��'� WOMEN'S RESTROOMS SHALL BE r dI¢ �, ,; 15 T 9 t I 3 t , I E 9 15 1 { t W ' ' I P PROGRAMMED WITH MAXIMUM AVAILABLE � -- 'I�,. .� i ;: ___ ti �.._., ;} TIME DELAY SETTING. ►r� Ip 17 i ;°� 11 11 '� --- 4 y 5 5 11 1 '.3 1 f 17 � :^`� TYP o F ROW, YP OF ROW TYP1 1 I I c r_ g : ,,a 11 17 I 19 TYP 2. ALL OTHER OCCUPANCY SENSORS SHALL BE o Q 17 I - : 21 I 20 16 026 0 20 16.026 5 22 3 1 [ j � a I � E MINIMUM AVAILABLE I I PROGRAMMED WITH TH y 15 H1 P2 22 27 PROGRA ED i _1_3 �----- _ _ _ Ty _ 7 ..� ,.w- _ 1 wit _ _ _ -- - - -- _ __�._ _._ _ _ _ _ _ ____._ _ _ _ _.� . TIME AY SETTING. .; ., � � �----- -------� g ,., .:� /f'' ----� � E DEL SE NG P-d ..i �':li f1 '1 a. .�. �I :.Nf '� , ij' �: �i :i Fi 11 ji ,t y LS ( `� : _y �iti�iv- ''r'a�LT�i'�;wWitf.rr.iirk + } q ; $� 1 j i 7 } ,..w w. f�., , a I �P �� 1 7 m 1'x.0 (..� � :_ � � � H 1 P 1 5 ?{!� 5 ' 1 � �� KEYNOTES , �t e ty i t ; 1 F s yrs_' 27 -�'.' TYP z 21 I - a,:_ gip{ �.L.. � .5.. ,»„i.+. .,_._..'' i 1•. .»t• t f 1 �, �° r +� y f $+.,.j { ,•,'•�"t } 1,} 4 I M � '� I ' i ¢ ; `� 1 j �) + � 7§d E .1 29 p29 _ i P�3 P X23_ P I - j1 �..; j�� H1 P1 ..1 H1P2 ,�.; _w I .. .,! r .. 1 V T T M0 NT Ff T R } P I TYP 23 TYP 1 6.026 PRO IDE UNISTRU 0 U X U ES �-•, r s d t k d. 21 ; { BETWEEN BAR JOIST. 15 { {tI I . _I _� } pi 7 22 p Hl P 1 - - I i H1 P1 ISSUE BLOCK . I � _•__. � ILL G P .'.i { 3 .n.. y 7 1 3 "k"« Sa „•S ' S' I _ P 3 TYP :...».,.._......»,,.,...,.._„...,,,..,.w,.........•,_n,_.w..w............._.,.....,.. .,.,...�..:.,..�•. ,......„n. !..._.,....._ _.,....., .. .,�:.:.. .,, s wag,I. ...;� _... .,_.,.._ .......__..�...___. ._,,. y ....,........_..9a _. ......_._.,_.... ..... ,...- - a3 ...._ ...,.. .,... ..._ '3 .... ,.... .,..w.....,........_._ ..�_...:_._..._ .,_, ...., ....,_..,__.._,., .,._.._._,,..__..ter, _. _ .... ., ..., - .p, - '�� } ? I .+) :,1..,"�'•,� � I .•"M1�'± � �ny. '(�, .P� � "_""'7� ; �o;:.,,�,w✓9 � }�4..� � ,�ri' J""+»�: ; •-.�..+.`,w� Pi, t� P7Pq{ li H t q{ E{ 1 {{ i v ,,, .r, Lfi'�_.`.u'w@ i� 1 I •I I' �E�+E ! ? 1 a f It ` P 1 1+H � kk � ,I } P t g -' SALES , ' P . P I I �'w" 3-...•'y ( , i`�' 3 E gF 5 •.r I p 11 °I 5 S e p P r I le.- .,. ..» ,». »». �•-»��"6� ------- ^_• :.:.,... ». '!'. ,p.. ,»... rrt„» w. .�a::sx..'�Y +- �.».»,�r,»-ASn {s�.:.,.,» „gC._ Nn:w»•�• ,.: :.., yxmw. y�,,.,:....,..Ww. ..,.,..: .. :;p-y,,^+a..�y�.,..,.. a�»..w:,. «- �� �,:..,w ....»,_,... g 1 sp II.EE P Pi, i , ,f 15 -0 - - ' � - - CHECKED BY: r 1 # t 01 _M' ' _7 19 � DRAWN BY: T P �. � , I ► I } I I I TYP I„ 1 I . Uri 5 f # I I FILE NAME:AJ 1 dL�_,t s 1 t i i P �1 i + I PROTO CYCLE: 01271 E 20 DOCUMENT DATE: 0410 »... ..,. _ �� _,,.,.w�.,_ _�,,--_,-,: ..» _ .... ... �,...,�.._ -. _..�._»...... �-�'�»». .... ;� ..,_ ,,.,..._ �L. .»,w»w_ __°.. -::,� ..r...w»..... .... � _.....».....». _.. ......_. -_�_ ,»,.».,..w.:.-.». _... ..., .»_._»»..,, ..».n.. ............._:.... ..., .a..�__._..__.... w. -' _ ` '`- 1 ._ _ 4 ww » IL p _ I VZWED FOR DO NOT INSTALL PERIMETER FIXTURES ABOVERE I I � am az4s wv.em,roe fma cie mu,am r�sr.,tP , , , I ; ; I ; I a ROOF DRAINS. VERIFY EXACT LOCATION OF 6P-Os I_ _ _ ' I ROOF DRAINS PRIOR TO INSTALLATION CODE COAPLIAXCF, ADJUST BREAKS AS REQUIRED im lu o„ 4 -0, ,} 15'-0„ 4'-0»; 4,_0„j I 7,_0„ 4,_0„ i I 151-Olt 4,_0» I '��-�` 'r~ 1,_0„ 15� }„ 15,_0„ 15'- 11,_0„ 15,_0„ 6,-�» 16,_0„ -•- D„i 16,-0„ i '> 0» 11,_0„ 15 15,-0" , ,-0„ 15,_0„ 15,_0„ > t� - ,� I �i� } I 3 a I i 4 4 + r d4111I { ° I `',d .. .._..... ._ » .•-.».--� -» �a _......i .n. ' n. w .......».»d �t n, _ .-._.. i I I t INSTALL PERIMETER FIXTURES IN THE SALES FLOOR P - -- _ _, j}j9y ;I x AREA A MINIMUM OF 3'-0" AND A MAXIMUM OF �L ) 7 °t20 I 4 SSS , „ . ' ��,� � -�- I �-�•-' � `�• I---t�--- � ; ---t�-- - �----1�-- -� � 5 -0 FROM THE WALL UNLESS NOTED 0THERW!SE. ` 6 0 P 2 I I IDENTIFY .STRUCTURAL CONFLICTS PRIOR TO TYP INSTALLATION AND ADJUST FIXTURES AS NECESSARY TO MAINTAIN CONTINUOUS ROWS 5_1 L�- l2 9 I t 1 i 3 i `J a �$ { •",t"'.• y ' } `'. ,." I 3..,.w' $ 1 X73 s Y{ �� 1 r E 3 � `1E .` e„ A '- ` x,20 I ¢ I I I I - I .I � �- � ► �p PROF 1 I Approved............................. 1Rt ass' 3 I ... g q,1Ca EF i a �J �I 1 •%. P 1 a 1 i �ax7dit►an Ef A roved. �` tf. R b, h �t'� ........a..........� �'a ,� :(/ �.�fa 7 � q Y ,,' u ;•' "d �+93 } 3 I I For a�ll 'fl N`arC taC9�.3J°'° �Td ) �� 7233SPE VIC` i 3 I I ' , E R til I i`1l O. ,. .... .,» ...._n,».,,w...... _,.....- --- ._,....Mw._,__......,.,.,... _..rv-...,,...w�..^""--,-�.'�e ,- .. r .. £,,,..�y+.,,�» --, "'•i--¢""';'r' '^---�' .:..' _ .saw-. ,�,.__._ ,... .., .�. qm� w.sn• ,w. :. ...,... w_ waC w.w..._.... .�.. .»» ..#.•_-.w .e :as:.wa' -..�.. ••o-._...... _.�._.w..,.d.. ...., 11,11. ..........�w.r... ..» .w.»»_n.» ,...... .._.,... ..».....,.....:w,.. ..w .»...:,..-w., ...,..m,..,.....__.n. ,«...,,.._,...,wn... .,w .,...»»w....:: .....,.....mow.».w..»..n, R -.wr...•....r.� '1111- 'am'5 ... ,w. .:a ) :s 6„/ t it #i t •'•�I V `''1� 23 1 31 r ;ww"w..,. i ..6_ r m r a r r.:r r a a or+r a 1 r 1 ,+ '�+� '1L,,1 �. W� � � 1 1 } r 9 , r . 4e ��s_��f?r to:Follow. ,. !✓ d �t � "t @✓ ?'+.. ¢ _ ,... ..., ..._ _.. _. .+.w 1111. _ _ _.,...d.� _ .I"�.,. I .bwmu.:l.'.L,�a..r.. �. ^ O a i. ���r �.-:-'a� ����i sr-. '""'�= �.��. ����� �+ia�i��� -'�.� "`ate.�'-� ���a.Y...�ai.� � c da _._..._. _._1.111 �_... �1111_1111 ,.,.._.._,. ._.__1111._ 1111. 111_1 1111,_ 1_111.. , '� �� I 20 s/- _ ..w_ Address,. s !,.,4 GOIV y. ,'. *. /' _111°1 „„,.,_...M-�. i •-�'. _, _ yp,_,._.,,,,._._. u� .����._.,.._,.......^• ^- a�Y �{ , _1111. n. a � L,�, qua 4. # I� A rE r. � •.�: I E wG ».,. ».. _,, .._. r .� ` �.y f�', 4s.=..___...,............. ...'� ? _.1',� .V. ,r+,.aw.,. `+•., , I d 9 V S 1 + dYx - 1"y I I _..»r ._ I 3 I ¢ 1 � k wit wLj t a (�-'- t I - -_ _J °' 3 ~- -- TYP t 1111 t s �. .tit}� ��w� � �Q, -7 � ..� � # �� '� �' `° I 1 •.a: s• r; �'" ��a � t t1 a € ,"�--- ! � 6 :k6EXPIRES. n 13 � ; � , { Ij EDC2s ` ' } a ..n.-.....a,...... 1111.......,».«.._.., fi 7R`%''r.' kitLGtL.. u1i :da.'�Ci " .w,u ,.. .». .......»».w.. LL a 1111..w.r.»,..,..,.1111..»»._..,.......w.w:,._......_. »........mow...,...:..»...,,,,,..--1»111.1111 111_1_»._,_1111..,..,"_......,..1111_......,.».ww .»»....r,..,_.1111..»..»..w�. .,...•,.r..,�. EYP OF A ''- >,..... r._..3 16.026 201I a � , tir s # $ ..,.nr,y'IC"�-"•'.� �•'•�.Y :.r !tL". 1 i t Lj- xaaf;so�etaoen•..ser ,ex mew•.swt• sa '•_'.w-^• t v: .� ._,.,u r..,_»• I, Lr,amx+�•t�a-.rte�star a P k ; �I 1111. i a r ' .._..._........w...._.-�'11�i7ii �YY1W1.�>•Iias1Y.YhY:9YI.lY�4a;YYY14,a�:-�.-.. � ,A�•.,`•'n _ _wr+.»....ww.::w.u _ _ 7 1 � a -� _ .»...,r�•:fn t�w.....Mrv.Pn:t uu'ui,a,.w"Iw� cs�,w^'Yv._w.-,aKta.X' ._,-1111 1111..,..:...,..__,.w w...,w+,,...,_...w..».n_.,w..n..+:..•....++».,..»...._.,,.,.,,,. ._., ..,..,.........,,. 1111- ...,...,....:..w 1111.._.w.:.,..»r,.«...»«,._.a.+.c._.w..u: :..»»..,.........,1111..w.,,....nw.wn.1111.,._.-..-r>.......0 ..w..+.w..� .,'. ..,...,,..... 1111 1»1»11. ,.w»•..» ' _ } .....,.,..._.,......._....,...._.1111. ...._..._.,,:....,...... .._..,......,:.,... 1111;.,�,.a ... _�w r 1 i ..;:.:, t ipF...._- � 1 # };�..,._....�_, 1»1_11.-�•. .,d,....»,•.-�,.,..w„., .� ..,.......,. .,_.,.._....y.... .w.... y.....,.s� 7rrr7�� 11 1_11_1. }}�� � j � �.ys '^'_•� q� � t ����i -. a.� _�-sato a���aMtiva-,��aa-�������������-f+_�� ��--��-$�.��-.�a��,�� -.a���,t� a` e' A I1 .� L_ �j } ...n' i '"'+ I i d t6. "t•._.:....:` } T ; : a �� I YP OF 10 3E } EI •..-� I I I w , .�� a _�J ! 16.026 20 27 I jGE1 ► �a�a 7y� I3 11 Es I { � � I I _-�r.._....n_.....�� �i,�.�..........., ° } , a w o a a E a8 arw:s ty.w.va.+ i r } I G f. • i. :..ti TICE '?� E1.1 ._.�.r3 -•:. " 3 a a 9 tl I ! 3 . I E1.1 I t LIGHTIN,,"� I I n PLAN t m a 1% r, a s1 eft 3 3 S 1 I 8 f a i W LIGHTING PLAN Y _ lot = 20P-012 SHEET. 6 o., a 0 KEYNOTES 16.021 IN AREAS WITH FENCE: ROUTE CONDUIT DOWN FENCE POST AND MOUNT BOX TO POST. IN AREAS WITHOUT FENCE: MOUNT BOX TO BACK OF SHELVING RACKS. 16.023 REFER TO ARCHITECTURAL DETAIL FOR LIGHT FIXTURE INSTALLATION. 16.028 INSTALL FIXTURES ON UNISTRUT. UTILIZE ALL-THREAD TO SUSPEND FROM BAR JOISTS WITH BOTTOM OF FIXTURES AT HEIGHT INDICATED ON PLAN. MAKE FINAL CONNECTIONS WITH FLEXIBLE METAL 5 5.5 CONDUIT. 16.220 INSTALL PREFABRICATED ELECTRICAL i DISTRIBUTION CENTER (EDC). EQUIPMENT AND INTERNAL WIRING ARE SHOWN FOR INFORMATION PURPOSES ONLY. THE ENTIRE ASSEMBLY WILL ARRIVE COMPLETELY ._.L_««,...�r„n.r.,wr..«r..r".�,,.._„_......_..,,.:w...w.....�..._..-�.... ,.:...� ..w,,,,,.......rw..,,...:.+.,.r+....._.•,...,_w,..,,,_r+,......_s.... F E...«s.r�. r_.p.,.�.»rl r....,,,.,w.w,w_..,..r,�t.r,,,»..,..,.,n+...,._..,.-...,.�...w...+,_,.,.,..e.._._,.,.,,,,...a,....+...,-..+..,.,w.n...,«.,",....._..,.«.r,..,.,.....,.r...._,.X.,� PRE-WIRED AND IS AN ETL LISTED o � T� aZ Wp EzQ •. ASSEMBLY. u W r-iE a�o z"'Z -- EDC1 p �za o_wNL .�t–o 14 16.241 PROVIDE RESTROOM NEEDS CLEANING SIGN, 0': z'0 N w REFER TO TOILET ACCESSORIES 0 mw 0:0 wt–�xc��zcnQ� SPRINKLER ¢ 16.220 �--�►H1 P1 I 0- J V W•-•Q W O D SPECIFICATION. INSTALL SIGN AT CEILING �'- a�'o���w�aWZ a� WITH LETTERS FACING THE COUNTER. SIGN z a2 z�owoo�o`�u t 3 O �ww�pO�p 1 61 �- w'z O -,0.Z pZ + +" P SUCH THAT THE SIGN IS ON IF ¢ Z m <°-Wwao 0ap3 _ � � � f AND SWITCHES SHALL BE WIRED IN c�aoow���o azza , 3 _ 3 PARALLEL S C S t O o J w N 16.021 o z z o o w�w a v�o�a i EITHER SWITCH IS IN THE ON POSITION w w Jr a- oowv,O:WWF owo Nwv ot- �'ao�c=ia:DF Ileq Fo9v'za_OZ ix jw<w<o:o:Q� t h Z)HI C)L4ftR� 09 un �su N E wo C' W ^ (, M EDC/SPRINKLER `"� �� ®- ;Y� C too z o •� o LIGHTING PLAN Z W ��as ^ Z c•tz d °o T 1 8„ 1,_0„ w M � J z W O V z koO 7 7.5 to c) �O ,!", r ? S t a F i�•^=."'rc, �•', ip G11 S v ..,.... 7�7 i j{ ,{ + 1 j f i r' t ...., .,.....r_ .,. ._. .,. .,.. ' Y t i � ! f i � 1 H `t r I t �p � t.._....C;--.. t._....._.-.,.._.....,....,.."......,,,.....,.___.,...�.r_.....,._..�-..���..,, ..� ..«............._ ......,. _..,_....,,,.. ..,»......_.,....,.........,.«.«......,,.,_..,,............,....«. ® O i h E. J Z t "r'"' I1 16 T'{ W O 1F d] ABJ C 1 g OTYP t ABJ 19 ® C� 1 f k H1 P1 ABJ E ABJ ABJ O " �, I 10 R Y ' a G B AJ I I CO.. _ .. p ._ . _ _ ,«.w, _-. .. ..._ I.-.., _ w _ _. _ ABJ I t 19 i W .,, ��, F O , I s ABJ fe ' t r""" ¢ a F t } 4 # F r.••w===-=;.�...... ;T;.;-�,=:,_....�,_.,,'"�r'"'`''�, °`'` f a _b�..j _«..,_..,_..._� 1 F�•� «,.,.,.2,,.0 ti r 1' ' t ° ( + i t C ` I �r;sw'-,+-...:.:,a- .;.:#„ f� I r r-� `•. ,F„� a �`,' g a t + �' i t t4o—d" _ yy 6 .E _� ` TYP 17, c� Z 7 „f• - } t # lj ? ` , ° ! hk Y 4 O = H 2P v'p^J. (N VOI CI N �I i t _,:, _,.� «__} f �`, z "D g:; 4 TYP OF ROWS a I s I R, m' i,. . _�_;� t z i + rl r ; ABJ I ABJ ABJ F rrr� ; 3 ` .. T._..INA a `` a* 14 1E _ " _ ± ? ; ISSUE BLOCK e *"""S tv^"r. f .sr, F . ,@ ' {ng.,--- "vmk�?a” i'. d # eBREA d NIGHT LIGHT, --,, s _ {� € 1 - . 9 ---~ _. _ [- --- -- ---- --TYP �. _.. .. _ ; ROOM° z � E ..•�._E.," yY.rr � i .,-._. OF 5 � y �� TYP OF 3 ��� � ��° • w3i5g�jP.„'"`' �''°�'i,i�-u c. 'r'°°e+a'mw` `e�.� � I � �E I � { � {,,, � ',,,,.,,""' � �.:-t...-.-...�t M F i '""^�"•,.,.._««�...,«_..,.. g J'�i I ;I s ! �ti,t, y. OS G# AB &18 ;- ., --� k � ` s yam• 1 16.023 _ i. ;_ , � r , #; t __ .,AD n , ._ # I Pi'�a J �..f k, t 0 E i 3".�r "_ _ fE 'i(t# 18 ; ; J .p # OFFI�� t }#p H 2P t _ ., F :k e=; 47: �7t „_. _.,+ 7ffi AB �tk{ /yaml � ; � ?�`Y+� � � 4: F try j �� �,_. ,..........»-__....fir. , j'4. � �/ 4� p � l t A 4'J�",,�::T.�,1:�.. C.•:._,..��„t? :_•'�''� ! �: (PART. att� F 1 -'� Y R E F 1—E1.1 3»,..,...... d ++liwrassusw d� 1' rr + �• . „ 1k, { 8 t y '�' i �� . MEN { �. i s} i I -^--'1� �' '1 V "r�_1PFQSQNNUL" 7! 5 i iit ! 8t �` 3 1 � J.^I+ ij �Hc dc t � � ✓��� �.. � „rNlwa,. r V 1� t• l ( r _ ' �^i { r � t t f� ° �., ! E t k }..,:. ,«.,. sane.^'- .._.,. -•-.» -..^.,-,,A. r, 3 � 1 t r ��/�t" ,I � ( t, g t � 1; 4 41 P "'o$, (y # y-�--•^•�-^^-��^^--T7p �} �, ...........� i},.T�_...,.,,..... + ,_,,...,,� �- ,. I... -_. t _", { a:�.�._.3 3� P€ t ��� L 3� � 1 � �� i � � p } ?� Y��.i ��,,� :+t �+�y •"�'�, t ..!! { ._'•,..t� ! �! ii 4� .] 1 � � � � r�'I�1' p R• � � i G � � i 1 ,'q� � � �.{ M� � � � r f4a E t E e.. '„ ,'A'. ». ,..t:. �«,•-,—'-�•'-„_3.,-•,'.""„”`-y i e � �' - ;,,,, i._.",.4. 1".""`".� � K...,�" ...,, ;� w � �t---'-'---'' S-•Y,.••_�.•••,--:ii F �, � t y ;t � 3 � i � 3 G >> pi;t ; a- !" � " � 9 6r, � i -.st.,.�.�e.., r q v � � � 4 i '°+,.. p� I >s y 3 r}"_••,°'..q y...�.�._.._;a rr"'•-^--` i c"`"'" t t< Y"!^'Y 4 �➢E e �..�.... ,. '^"'€._ l t € t � Ir ¢ x i ii t F � + `�. >.� a .,r R n ��___r�.. —�e � Y""•�R � � }. � ai g � '� ''3$•t'�i?�tenreu�u �attueramu�lwwm�r te+a:, X� �: r! ',r d',' [ I �. i a E e � a ��. �,...._.,,.. � , .,,,i r er"g r a -�- { i ' r rix yy . r�-•'�#�`� .-.... . .,..._� .If'A!:F,.. ,_._.. . _ ,,.........,R:3a�"'. � _,..... ..a.,E.. t`t^a-i d -. y ,. .F r-,..:,»__.,., „_.,..._,.,F•,,.,,,....r.,.,..,,.....,_..,......<_...,t :t v ru.«ac«. 5., r.,� �11 i"1- ,_-wtr._....... _,,,.t_'••-_.,,. ,.. t S F � 'Y. ! 9y`� r F�"? f�r. € ' � i t ' ,._...,., ••--,-„•• •1 ! � i aS � � F s -- D ��; �,� 1 e t 4 l:A -.,..>~._,v�,...." '•„s' pp i :r ,� i t i � � 9 9 7 - $ 1, t s "� ^� j '� �+. b z�- .a e .,�` § � `{i 7 i -""� ._,...,: s� b� 4 a _"�,' ^••�R �! : � �� { 5 � ~, s � S tp'ga yulnq,. ? d R�� l3 i ,� i t ;{� � 1�,t t � 'f !{ r � s r��.�..r�L,,..f I... i + �" `+�''' '.M..2 Y""�' ..,.,.,;i R 2,..,,, �a � G 2 j "I: {�-•••-l}�-_•-•. r � i•t t f t .}q�;e �.1 ,� i I S + UPC � -J .E•,_-i- ^z,v-.._.. - v...____.,..... ut.. '^""^'-•j^__- .•t•W'S a ,'C'-v_... P! _...� ',� �' { V � t ! I Y t� I�°• SS a5� ,.,d,,...... �.,., ...t )}y _ 1 r E([{`I!� i + s r: v�` ',.'7 F_,..-'6°; 4 _§_._,..."j..i k : A f t: t • fi�� 1} R� 7 {I — t V + # i Y.' i `lI, Y ! J I !. 7i 4 ; .m.� F tP �'�4 s r _ ._a. h ..._-�.•�._..3,, P, € {, r r.. i h _ r j yy 3 �. ,.� `g�` t F F q' 1 t �-� FA YLA ��- -��- i- MIL is „{... rt b iia... V `�•• ,....., i �f° �; A.3 ( _ x + i e .: is#' 1 F a s i r. � 5 t I'--,.�+�'.� �i j r q F f / i t 3� �! t: q!9 = r .� t t 1 R a _. _ a F s ��; f., e .:.,... _«... .\r_ �..,.. 3 _� .,. .I [ t; 1 1 t t t 3 R t tr'-? ,f + .n. i !r.'. t^.,.. �i ✓•;^ _.Y f ,.�':� TOILET a � r ..._,....�,_ a � r't! a t:..._. B } I`• i5 a= L, s J^' -may + k' t # q ti i�: + k +l 1 p r, 3,:s t�,,.,»-.. �,,,.:.... t 3 V.,, 7�•„i: S ... j .E i � 7 ��' � arc' y i { R t it. f si ��3/ a� � 'vy M,._ ,.x.:..•"-^••..a 3 010 'i � ABJA O Yc.•.• .. 1.,,,,..-,1 LC E i t ri R t it'Y' E i "}3 s F �'. �FF � p. � F _.,.,...._...._._,.�....., ,.,.". s t . ....i g 4 ,�-.: ;s;PHARM C { 1 + r 4Fthr4 k 'g Q 4 i Fs:a_nr 2f. T'4-F ,., a _.� !_,i. e1� C + r � L-., �..E.m.,. ..�1 t �-- x,; g f3• t ; � �' e � � - BL � TRAI1 �w,. i r 3 9 k. t =e..= t.. �a � 4 d .-i x ' # t tai i a• ;R ( :� ( { x,F ,q ! t z scnavrc<nn x� ,IRHARMA C Y - t _ '7 z ; tt TYP ► i € 9 1 __. _ , c > x - _ _ I -- r �- t n ; g. r .. _r-- 10 t a i t"!` 6 f4 + - h -- "� € '�' ;' r fir---�t.: _ x { t t a x ae ww nee s caa I' 9 . t k t i ga {; t I6 1!� r t . T01 LET b WOMEN Laf`lJ� p c- # JANITOR ! - ,�t*--.�---- t = s r I 'i, 117st F !. .. E r t t ; g v }*-�•,,j' R l,.,,.._. f E i p s6� �� � �t � {� � .y � i .r t t t �I� az�,e kwW� ;ri two& erm*gantecrrt i .O• � � Gr 9 •r"' � ��'It S't � y f [ v %j F '•-••a a c�i :""°°`t",}- ri , t +a, 1 r� * 4 T � t :: 's" r �"�""�� � j TYP 2 68 � ��...._.:,,'.,..,.,1 • 3' d. S P � � r s+.n- : i � �."...�.._....�..-,per., 6_..,..�j p . , . -.•".-_ ,... .,,.®. �k� {ifpj�'''. S t { �,; �wucw.....,_,.,..,..wS,•.....,�.t'e..•ri."�_'^a- »tom E,�ua�:...,,,�.__..,.,,..r"".�..�`.t ; � I�-A�.LW.�' t 3• � � I � _ t(�� 'W� € f F�.,.L .4n.m.R? � 3 � a �# S � •� €f (� Fa a«_,«_,...,._,.,,................. ....,: 4 �. # 1, � I � •r'^t � s ryYr, { � � ! i !.� !�. t _ d s t '"•f._. d t 1 H a _ L, F i3' k_,,....:�,W-,,.»..w�..�....".......m._.•.,.,, .......,...a..�,...,....._.,._.,, .®,.,..,,...,,, ,�.,,:.... � ✓ `�, i v fi :4+' !r4•: J.'�y"""' t � t "tµ' .a �." ,....�..,.,,•r,"ti.. r..,�:_...,�...-.........�,..,.�._..,....�..., r,�..,.,..,. ......,.._.�.......—,.......,.«»_.,,, ,,..,.,,�".�.,�..,,,.,..,.,«... ..�.. ..,, .., r �,..x,.,.,,�,.. R_.,...�,.. .--^,�--••"^4- a'.. ,o x -;�•-�-- c fr. o° , PROVIDE STEEL ._,�.._. - - °� z 4 .e....,..,,..«....r,...»"..t. ,,..,..,,,,_..,._.,.,.. ...._.,,, „•...._....,_,_....,-.,,,,-1...........,_,,,..,,,...,.F..,.,,___._.....,.,.,.t..,.,,_,."..�,..i:,_.:..,...,.,,..,....._...,.......,....,.",,...,M,.,_„".,,._..,._..,.,,.,......_,.,.,,«..,",.,.,._d,..,.._,.._..,.,,.._....:..t..,.. ,.,.,,.{...,.,_......,.,.«..,...,! 6 _ ` VER�'cA- -=, -NN 1 CHECKED BY: RESTROOMS AND FAMILY TOILET TO CUSTOMER SERVIC k REF 1-E1.1 ; p DRAWN BY: TLC � R PHARMACY LIGHTING PLAN FILE NAME: E1.1 MIND 1/899 - 1'-0„ / OFFICE LIGHTING PLAN. PROTO CYCLE: 012712 f 1 2 DOCUMENT DATE: 041012 4 5 5.5 6 6.5 I • TYP OF RO x STORE 16.023 53B MANAGER'S TO REAR RESTROOM OFFICE REF 2-E1.1 t ------------_--______ _-_ ------------------------ �- _�.__-----.�___ --------------------------------i..-__--_____.�__�._-___,__-____________--...�.�-t--_-____-�,__. -----,___________._�.�._----___R---------------------------------- _j .�.______-_�.-.�____w________�.----__- 16.023 53B �' � � , ,�a '�c�:.:r Y„-.-„•...,...,.�x':.',,.,,..�.; ^;sz...^-,a,•%�•:. • s.'wc.^'ce.x.,.:. -- "c,.s•'.:. '.�.«''r „«»"^:ate-` `""_ �. �....,»,.,_.....�' """T” _,. »., ., .,,. ._,. ......:-. ,._..... ...., .,,. { `-T E.TUPRN N." © 2 � r STORGE � ST)RAGE 01 iPt I 19E t, T R- 1 d it { l I r� F 54 9� – rat � �� sa r 14 ® I , t r PRdI� 16.02.5 53B F t� I GUS T OM crR WI €F N ► I , ,. .,� , ' �., 7 c %.- go NIGHT LIGHT, �i SER /ICE rt rc g �G1NELc / .., ,�k "�O TYP F 68 f �'I�-1:P1 REFERENCE FOOD ... ... ,r _. Y F ---- i .. f � t � { 1 K F 4 N 33-1 SERVICE TENANT SHtETS �(° I. , 18 F ! c J J 7 I 7 ��'E t `•-': -"" ' ;,' t F '1 i, t : a T., taa,atvi ala. `�bw . "°+ti:ra� is a \�`. +L•rapa'' ji t! 23 � t n � I � �. Ia FOR WORK IN THIS AREA ,� .._. -'; .__.�.-r-'�------ --, r II _.—_.— i 8410 COUNTING �G2 1 TYP . ..� .�_. .i - .-- M MEN 't, . �j, OR ON o0 0 ! WOMEN �1 ti t� , A' 0; 3 , r 7 ---~- t ( -ART. �/2 33 2 €� / �.,, t ,fit ,v ¢�, j � �� I$ •� - t � x€ x t ;;,� � _ ;�""""1.-.r�t__.�..,._�•�• � �"`����' ���� °t�' ���,-�•s (y��/' . .. ._....... ..✓ ..._ _� ......� �. _........._.. ..�. ,.... .»._____.. �._.... _ ..... ...,. ... ..... .. ... 18 I t t `° '�(-f'-�rR�T:1-~/2- ._.. .`_` _._ NIGHT LIGHT, . x 4 PIRES: REF 3-E1.1 16.241 Nj I' ;+ TYP 16.023 68 , 2 O ITYP OF 4 PROVIDE STAINLESS STEEL TYP OF 2 . 1. L_ _ - COVER PLATES TYP IN A H2P1 1 t I F I N I . .. + I RESTROOMS AND 'A MILY TOILET o t{ --- t_i € 1 t: TYP .. f' ", 15 0", AIM FIXTURE t t ��' �• � � �� CASH 2 3 � � FOR OPTIMUM 70 € 1 I ELEC. RM. .€w LIGHTING OF FLAG q ..,,_,..:�... - - - --.,.,....- . ,..:...,,,,.,.,..,�,".,..,,:d,,......,.,..,_,...,,...:.«.............",.,.".. ".,�,.,,,._,....,..+,_.,,.....+...,._,..,„,.,,,.....,-,....:,...,,...,. ....,.._._.. Y ... ,._._._.......�,+,x'_ �_...�...._. -.; c c a,_...,".«.�5......,. H t Req jt � ..•.,,, ,,,,,,,..._�.«_.w.� ,.,�.�,_. • ....,.. ,._..,. R'i � VESTIBULE El-= ' OC TYPO ' ►: 1_..NL J *��r . -.---- I � � a CART a� � � s t �� � � � ENLARGED ------- -_ STORAGE B LIGHTING SUSPEND TO +12 -6 �r � PLANS ' a TYP OF 4 ROWS I w_._..,.:�... "F:.,..., h.�.tt�.,�.,....��:T:� ,j.,�F"_.'.'"""*'^,�'TS.sbF,':.'�'P-�:..•_.. L-.G-�."a1t�'`, 'td.�(�_+-,...1.-�u�••a*.�w^e�'k'4�ML �,ara+rz r w Wit'�� �.5 .ucw,.� 1!i .eyu:,v.w::j;{cc,res�Mn ! �'+•-c+�-”' � # 9754!1 cr;%R b . ••^_�^*•,� �"•'•�•�••,•_, 3•••••,,w••�n••gmlariaiy'p'v,wu.�c+_vactcgpn- a,�w:u wnr:«u1� ..ya,_;rm,• K ,nluoa*,•, �sv"�wr.,cm...r6wt,;wn ��:urwF'uwmw q 1 1 y j7 t F R d t 3 �. ...� p �.,. ,, �� r �} T LIGHTING PLAN. M UN�, TO UNDRSI FRON N. .� I OF�6ANOPY AND 27 i "_: 1/8 = 1'-0" w COI�dEAL CONDUIT r Fm � 2=3 Q SHEET: 0 o >, • Q o NO CONNECTION OF ANY KIND SHALL BE MADE TO THE JOIST LIGHTING FIXTURE SCHEDULE WEB MEMBERS OR JOIST BRIDGING NOTE: ALL FIXTURES AND LAMPS ARE FURNISHED BY THE OWNER FOR INSTALLATION BY THE CONTRACTOR PROVIDE 1-1/4" FENDER BOTTOM CHORD PROVIDE FLANGE CLIP UNLESS NOTED OTHERWISE ON THE DRAWINGS. WASHERS, TYP -- OF BAR JOIST (CADDY M24S OR EQUAL) NUT AND WASHER NOTE: REFERENCE SPECIFICATIONS FOR VENDORS AND CATALOG NUMBERS NOT LISTED IN FIXTURE SCHEDULE. SLIDING HANGER LAMP (PHILIPS/GE) 01.27.12 SLIDING HANGER FURNISHED FURNISHED WITH WITH FIXTURE, TYP FIXTURE, TYP TYPE DESCRIPTION VOLTS WATTS ORDER NUMBER QTY MOUNTING TIGHTEN FURNISHED 1 8' STRIP 120/277 112 F32T8XLSPX5OECO 4 SURFACE HANGER SCREW TO SECURE HANGER TO FIXTURE, TYP 2 4' STRIP 120/277 59 F32T8XLSPX5OECO 2 SURFACE PROVIDE 1/4" HEX HEAD TIGHTEN FURNISHED BOLT NUT AND LOCK HANGER SCREW TO SECURE 5W SECURITY LIGHT 120/277 101 INTEGRAL LED - WALL WASHER, TYP HANGER TO FIXTURE, TYP ' f ..,...... +��� ,�� ._....... .........«_.,. � ���.....,,.q...__.. —...... _.,_._.w.,�...._....-- pro^--•,.��;y _. ,r.. K 10 2 x 4 TROFFER 120/277 74 F32T8XLSPX50ECO 2 RECESSED ,! • ,, s j ., `�, wV) o o BAR JOIST a a� z¢ 0 cr END F BOTTOM D o0 908 2 ' �� CRD OF BAR ,` � aQuj *aZOoa2U�aWB 11 SECURITY LIGHT 120/277 20 INTEGRAL LED -- WALL •'� IST w k' �w 1�' a a r w L'a m 12 DOCK LIGHT 120 90 90PAR38/H FL28 1 WALL 20" _ �� -� ��._..m _.._..�_. .�_ _......... _� OL—Aw a"o�� W w z 00 Op z 13 EXIT SIGN (DOUBLE FACE) 120/277 1 INTEGRAL LED - STEM / CEILING +� , w__�v___ .�M.___. ..._....~ _ _._ �� LIGHT FIXTURE REFER c�aoow0� azz¢ a __�. ._ _.� _ z cn n. _,o_D: r��- O 4 ARCHITECTURAL FOR + ¢ * MWQ WORK6�npdW� ATTACH AND ALIGN FIXTURES ..,� aQk'af--Z�w z,�,� i MOUNTING DETAIL USING SCREWS, ANCHORS t . Mzz osiwF`'`f``www 0w `'"' 15 EXIT SIGN (SINGLE FACE) 120/277 1 INTEGRAL LED -- STEM/ CEILING 1 I --"-- Ili LIGHT FIXTURE a' cQw"mi-�`'waoac=�a��� a AND/OR TABS FURNISHED -- c~n �� Nzolma nuo- WITH FIXTURES PROVIDE 2x2 x3 16 t JOIST GIRDER / 16 EXIT SIGN (SINGLE FACE) 120/277 1 INTEGRAL LED WALL LIGHT ANGLE IRON (2 PER SPAN) ' FIXTURE BOLT ON BOTH ENDS � CONTRACTOR HAS THE OPTION Z 17 EMERGENCY LIGHT 120/277 2 INTEGRAL LED - WALL 3 I %A o w #16/3 SJ CORD TO USE EITHER METHOD OF PROVIDE 1-1/4"FENDER ®� o AND PLUG FURNISHED INSTALLATION SHOWN WASHER LOCK WASHER T 77 I W � E 18 EMERGENCY LIGHT 120/2 8 6V,20W SEALED HALOGEN 2 WALL I WITH FIXTURE AND NUT, TY tu M o { , `� i CONTRACTOR SHALL PROVIDE AND FIXTURES SHIPPED FULLY ASSEMBLED W -e— en v, 19 EMERGENCY LIGHT 120/277 8 6V, 20W SEALED HALOGEN 2 STEM FINISHED RECEPTACLE AS CONNECT ALL POWER AND CONTROL WITH ELECTRICAL & MECHANICAL END OF BOTTOM � ®� �� / SHOWN ON PLANS WIRING BETWEEN LIGHT FIXTURES WHEN CONNECTORS FOR CONTINUOUS ROW `�-�-` WYo .� o - FLOOR ROW OF FIXTURES IS INTERRUPTED MOUNTING CHORD OF BAR i�C'� �Mo s M 20 8' STRIP - PERIMETER (0.88 BF) 277 56 F32T8XLSPX5OECO 2 REF DETAILS JOIST z �Z co N • "f _ � TRUCK DOCK LIGHTING SALES FLOOR LIGHTING PROVIDE 1/4"HEX HEAD 0 21 8 STRIP MASTER (0.88 BF) 277 112 F32T8XLSPX50EC0 4 REF DETAILS q.. 3 BOLT AND 1-1/4"FENDER z w 5, NTS 01.30.04 EL09 NTS 11.27.09 EL05 p ~ c WASHER, TYP v 22 8' STRIP - SLAVE (0.88 BF) 277 112 F32T8XLSPX5OECO 4 REF DETAILS 23 4' STRIP - PERIMETER (0.88 BF) 120/277 29 F32T8XLSPX5OECO 1 REF DETAILS ' 27 EMERGENCY LIGHT - REMOTE HEADS 120/277 6 6V/12W SEALED HALOGEN 2 WALL 2 #10 (CKT. #11) 30 8' STRIP 120/27/7 1112 F 32T8XLSPX5OECO 4 REF DETAILS 1 #10 GND 50 ENCLOSED LED LIGHT 120/277 59 INTEGRAL LED — SURFACELn Q 53B TENANT SIGNAGE WALL WASH 277 60 F54T5/85OC/WM/ECO (51 W) 1 RECESSED --►---- � �=� '� � H 30A, STORE SIGN: 57 SPOTLIGHT-SPECIALTY 120 12 LRP38-10L-25D 1 BUSWAY �ur . 11 / � $ ; ; `° '�,•. t+. �. , � y p o #10 (CKT # ) j w .—- x_...... ' �°�, k � �, 2 #10 (CKT. #31) 3 f 2 #10 (CKT. #27) f __-; .k:.° _ d w4� ;; 1 #10 GND Z 58 GLASS PENDANT LIGHT 120 5 INTEGRAL LED — MONOPOINT CEILING F� g .._ ;f / f 1 #10 GND ` Lu »c. IN 1 f -- R . 68 DOWNLIGHT 120 13 INTEGRAL LED 1 RECESSED j; � ---~ k' ��. •� ..�...�; � .,�` ��,,� ry �.�....... ..�.�... P�7 f' 1 w� ++. x•.•`".w" .r'^. :..»p...+ """•.' ..,. .:...' '""�.:...'"" .;.'__.....r......,. M.��:...:.. iW�,u,:: ,-:_..., '" ."'i_".^�"w'v"M......�..........� �^ ^»1..^.+�7«`.'.:"'}�..�"...� O O O 70 FLAGPOLE FLOODLIGHT 120/277 185 MH/150/U 1 WALL f ° � :� _ 1 I $ I I t = k B SUSPENDED INDIRECT DIRECT 277 118 F54T5 850 WM ECO 51W 4 PENDANT jl , F32T8 TL850 PLUS ALTO 2 SUSPENDEDC SUSPENDED STRIP 120/277 32 n� ? 01(4 12 #10 (CKT. #11 t ,....-._.,. D +1 SUSPENDED STRIP 120/277 70 INTEGRAL LED 1 SUSPENDED #10 (CKT. #27) " I x t ►-� 1 #10 GND If 0 „ .' y_.� _""" i : + ! I = a y ( G"�as I € I { 5,._ ✓"" (s i N 1 C. h� /jj , —2 #10 (CKT. #31) 2 #10 (CKT. #31) ` 1 #1001GND / 1 #1,0 GND ' IN 1ISSUE BLOCK C. y / IN 1 C. { 1 { 11 €I t} 1 — . . A,,......,..,_ �f t,N.- .,� —,—I— r �.:.-+-- —�s ��i f --r...,:._. •-�� 7 : E 3 it �� a �I 2 #10 (CKT. #30) t 4 r " t ` L , 1 1 #10 GND 2 #10 (CKT. #31) 10 (CK . IN "C. 1 #10 GND ` 1 #10 GN DT. #31) � Ito -I If% Xz\ 1.Sir )�j I I # F �• y"+' i # + X" ! f 4 I { 1\ ,r!.^..-' „ "v'\„ ���~r..• F 9 ii 7 ( � tea+ fj j 1 ii !EE I `'r+� j I 1 1" t 3 ; ! r t a t ` t I �E " j F � E I i a {' I t y".. .-- •, �x-^"" 7 { r 4 i _ _ { } ` r {� .� _ x 4 j d i� , t 4.._� i �7. ! g. .. j f 4 t� iy rf ^, """""�«.. `t �1 arrs=;i f f""} t, +. ! 1 1 1 ; 9 .ten..... ) f^ q. 4"h �6,, \ •q+• p � I ( 3 j '` r rF 2 #10 (CKT. #11) � ..'"" ......�........,._,._ ..........,..,_...,._. .M� � ar 2 #10 (CKT. #27) d, - ___ ____ t 2 #10 (CKT: 1' 1 #10 GND ,\ 2 #10 (CKT. #27) ,,+ '',. ' IN 1"C. -' J ;: 1 #10 GND ` IN � (( f f ` 1ell- __w_ 2 #10 (CKT : ,r 30 ) ell' ; ��,,• '' ,. ` a—, I w:_- . -.__ - _ 1 10 GND j �' ,,"''`�,✓' t'' �'A,r'" •I k � 3 � #-w ,� � t & f I j g � � � � f� � � i � ;i y � � ' ,,, ""`".^`"_'.�. ...,"^+--,..,,~�,,.,., : 1; Al E. j i wx 2 #10 (CKT # 0) \\ / ,0 \ 2 10 CKT. 30 ° -..�. REF CIVIL SITE PLAN FOR FIXTURE TYPE 2 #10 (CKT # 4— ) ^ "'' (PAIN 1/ \ 1 0 GND # ) _ I 1 #10 GND . 3,, # k = P r ,t 3 r �aa r t 2 10 CKT. 11 AND LOCATION. SITE LIGHTING PLAN » �� a Es 'i I I- 1 r 6 I ��'r; °�,•,`� # /( # ) IN 1 C. F j f�"°``� �'�., IN 1 C. CHECKED BY. �l � I E cl € 1 ` s G 4 # l 71 ) It .'`'f I " 2 10 CKT. 19 RECEIVED 02/03/12. : fI ,h- I,� 2 #10 (CKT. #27) t}t� ~ 34 DRAWN BY: TLC, ( F i Ct na�u. 3i: ; ..__ _ _ 1.�........._r I'•� "^ 'L.:l i• B x ,` - r- ✓ ",, 2 #10 (CKT. #31) t I c 1 #10 GND _; ----- FILE NAME: E1.2 lig i t t k1 ff 2 #10 (CKT. #11) SITE LIGHTING IN 1 C. 2 #10 (CKT. #30) V\41 ,° ' E i i a ? PEN TRATI ON i 4 s t I I 3 i fV,�,� ���!� � �f�+ � ��� � � 2 #10 (CKT. #15) 2 #10 (CKT. #34) �� � � �� ��� �� PROTO CYCLE: 012712 k¢ 2 #10 (CKT. #19) REF —E2.4 3 �� 1 10 GND 2 #10 (CKT. 27 2 #10 CKT. #23) # „ ! I d , ,r ► 2 #10 (CKT. #30) DOCUMENT DATE: 041012 # ) 2 #10 (CKT. #27) z IN 1 C. ., ," �. s 3 I I1 #10 GND t a � 1 10 GND „ 2 10 CKT. 27 J . IN# *IC x a 1 #1�0 GND s _ �-� # # ) 3 �.I 30( AR /Z B- IN 1 C. I 1 C. �I 3 f INI 1 C. �____N2 #10 (CKT. #31) 30 P2 GND 10 1 j� �, # HlP2r r J, H2P1 2 #10 (CKT. #30) �.—.. � I 1911 1 #10 GND / -�.. 15 BOTTOM CHORD ATTACH AND ALIGN FIXTURES USING �"'\, �& 27 23 IN 1"C. PROVIDE 1 1/4 FENDER OF BAR JOIST SCREWS, ANCHORS, AND OR TABS -_.,t 31 19 +I / WASHERS, TYP / 23 ," `\ti FURNISHED WITH FIXTURESa --.R �a ° i r _ , -�- J 27 IES /`�_ 1 i s € I : o -�� �- r 2 #10 (CKT. #30} I _ 1 #10 GND SLIDING HANGER FURNISHED UNISTRUT SHALL SUPPORT NO ~" ,, . - _ W —_ =-° " --�---- -- - - - ---�-I-- - # f IN 1 C. WITH FIXTURE, TYP , MORE THAT 100LBS IF P3300 �` - ,� �-�.,, b - --�- -- _, w �� I SITE LIGHTING E �t f IS USED AND NO MORE THAN 30A, STORE SIGN � � A i _ � 2 10 CIT. 5 PENETRATION j _ �. �- TIGHTEN FURNISHED k�=,°',r. «°,�:,,E{:., . -� ____ _� � ( I # # I Ll REF 1-E2.2 215LBS IF P3000 IS USED ZZG : f 1 HANGER SCREW TO SECURE 2 #10 (CKT. #15) -- 2 #10 CKT. # 9) } HANGER TO FIXTURE, TYP 2 #10 (CKT. #23) 2 #10 (CKT. #23) ' INSET � ---�. �~�.., 1 10 GND 1 #10 GND BAR JOIST -� # TYP 15 I I f I I '\ _-._. � PROVIDE 1/4" HEX i t j HEAD BOLT, NUT AND -- ,.. -- -�.. .. ���'�•�—.�—..,._� P.,...,. 1 , � ,; �' �-°- JL@ , 2 10 CKT. 30 LOCKWASHER, TYP INSET Z2 #10 (CKT. #15) f .. `-,, r -�-- - --- — j # ( # ) PROVIDE UNISTRUT PER .� .�-��'. . I F to : f - }Mw._.__.__. I 1 #10 GND 1 #10 GND 2 10 CKT. 23 ,�' `. ! , + {{ SPECIFICATIONS. LENGTH AS # ( # ) ,. w I , 1 I , O FIXTURES POINTED TOWARD IN 1 C. I N 1 C. 1 10 GN ,'" ,. # D --� 10 C6T. 15 THE BUILDING SHALL BE I FLANGE CLIP (CADDY M24S OR REQUIRED TO SPAN JOISTS. ,� .,. ' 2 # ( # ) .b� EQUAL) NUT AND LOCKWASHER �r�''.w° —:: SECURE TO TOP CHORD OF IN 1 C. ! ' ,,y: 2 #10 (CKT. #23) CIRCUITED ON THE PARKING ' '�I i ;R� 1 10 GND ` SECURITY LIGHTING"T ING" CIRCUIT .r~� ,rte;r•''P ,, BAR JOIST. r �,'` # » I /—PROVIDE ALL THREAD CONNECTION .„,� r1s+'"'"`" 1 � i s d : f 4 + t t G � 6 � � � d rC i �s , 1� x ! .R 3 � s 1 h 1 �6 �t, nr ° F P 3 t F t d #, 3 ? • 9 r FOR END OF ROW FIXUTRES I. � � � rn . � EXTENDING FURTHER THAN 2'-0", '� `� ,,..w � �, ti��.w�- .-•�.__.�_._.�..•.,..,�........�..._.,..:�..___�_....� f; �� .....,......... .� �x � � � i;E � r •<<cQ`� N �S'cS j REF MANUFACTURERS GENERAL ;�r�fu +rF;,i, ;;; afar �, '" THE STORE SIGN WILL B INSTALLED BY OTHERS. '� . .- UNSUPPORTED , ,� I{ € II .... O E ; y9 FITTINGS SPECIFICATIONS" FOR ;; J �10� K �. 1� MAKE FINAL CONNECTION TO SIGN AFTER � r DESIGN BOLT TORQUE t # ( # ) �. 72336PE INSET \ � .•� t �`�� 2 #10 (CKT. #23) �' INSTALLATION. Ise NO CONNECTION OF ANY KIND SLIDING HANGER FURNISHED r ,�" ° 1 #1,0 GND ` -- ""� WITH FIXTURE, TYP 'fir' IN 1 C. NOTE: SIGN INSTALLER SHALL PROVIDE THE REQUIRED I, �® a SHALL BE MADE TO JOIST WEB �'. '' . 1 STEP—DOWN TRANSFORMER AND DISCONNECT WHEN Ogg N 20 MEMBERS OR JOIST BRIDGING .� 5 ! _R TIGHTEN FURNISHED 2 #10 (CKT. #23) .� �- ____ __..� � �� � SIGN VOLTAGE IS LESS THAN 480V. � ` HANGER SCREW TO SECURE 1044 / � fCONTRACTOR SHALL INSTALL LIGHT HANGER TO FIXTURE TYP ¢ �` 1 #10 GND ��; ,.� —.....,,� I---f S 2 #10 (CKT. #30) �-- lq9¢ p y V FIXTURES PER MANUFACTURER } ' " IN 1 C. I / 1 #10 GND PIRES:06130/201 IN 1 RECOMMENDATIONS PROVIDE LOCKING f x " � ``�`"'` 2 #10 (CKT. #23) SPRING NUT , ' a . ., / CONTRACTOR HAS THE OPTION TO USE , 1 #10 GND �,�� BLANK MALE CONNECTOR ,,, •i �� 2 10 CKT. 30 EITHER METHOD OF INSTALLATION SHOWN ALL-THREAD SHALL BE e'f IN 1 C. # ( # ) 2 #10 (CKT. #30) / AND DECORATIVE END CAP ,� � � ''� 1 10 GND A SOLID PIECE. NO I _ " # AT END OF EACH ROW � � �� � � � � ° � � f "��� # 1 10 GND FIXTURES SHIPPED FULLY ASSEMBLED '' i " `� IN 1"C. ' SPLICES ALLOWED .�°"� € p �e a I I I `' _ IN 1"C. FURNISHED WITH FIXTURE , __.L_ r . — =w� - WITH ELECTRICAL & MECHANICAL ,/ ..--- r. �: _ .— T .- ,+ � ..... �✓ 11, �nnewuw,xusaoiwtxnwu•••••,•• +ussa3wiwais„tumuay'ruwm.+.zmw�ww�amv�' "��"`�' SrG�.:.:�'.wwuc:�urwa:N.v:ruunaru,uoa' ,,,,,,r,........•-••---•-".......,.-, ""'u�.x � +',� CONNECTORS FOR CONTINUOUS ROW y``~ MOUNTING SLIDING HANGER FURNISHED � ��, ...-.�m--• ~�---.�.,_,.�...—...�._.....-. _`"�-- WITH FIXTURE, TYP UNISTRUT .y`� �" ''' �-°"�-"� "``�---- ———————--—— —— LIGHTING CONTRACTOR SHALL PROVIDE AND ,. CONNECT ALL POWER AND CONTROL TIGHTEN FURNISHED +� DETAILS WIRING BETWEEN LIGHT FIXTURES WHEN HANGER SCREW TO SECURE "N,,u ` `' ' PROVIDE LOCKING 2 #10 (CKT. #23) ,�� � �, '' ROW OF FIXTURES IS INTERRUPTED HANGER TO FIXTURE, TYP , INSET `r 1 #10 GND — �.., _ ,,. .-- - AND ' SPRING NUT, TYP » -- �- PROVIDE 1/4" ALL—THREAD, IN 1 C. 2 #10 (CKT. #23) SITE 1-1/4" 1 #10 GND FENDER WASHER, LOCK � .� ...-._�. IN 1"C. WASHER AND NUT, TYP LIGHTING 4 1ROVIDE P , SALES FLOOR LIGHTING / ” HEX HEAD BOLT 1-1/4" FENDER WASHER, AND INSET ,� TOP CHORD Q 2 NTS 11.27.09 EL02 LOCK WASHER, TYP OF BAR JOIST SITE LIGHTING PLAN _ - 1w - NTS SHEET: El 0 c� a • 0 GENERAL POWER NOTES 1. TELEPOWER POLE(S): MOUNT JUNCTION BOX(ES) TO TOP SIDE OF BOTTOM CHORD OF BAR JOIST. INSTALL FURNISHED PRE-WIRED POWER POLE AND TERMINATE PROVIDED FLEXIBLE CONDUIT AND WIRING TO JUNCTION BOX. PROVIDE UNISTRUT SUPPORTS AND HARDWARE TO SECURE TELEPOWER POLE PLUMB TO BUILDING STRUCTURE, REF POWER POLE CONNECTION DETAIL. 2. PROVIDE LIQUID-TIGHT FLEXIBLE METAL CONDUIT AND WIRING FROM DISCONNECT SWITCH OR JUNCTION BOX TO EQUIPMENT KNOCKOUT OR ELECTRICAL CONNECTION POINT. 3. WHERE EQUIPMENT NAMEPLATE PROTECTIVE DEVICE RATING DIFFERS FROM SIZE PROVIDED, CHANGE OUT BRANCH CIRCUIT WIRING AND OVERCURRENT DEVICE TO APPROPRIATE RATING PER NEC. w N moo& oa>nr azzwo Wiz¢ 4. ELECTRONIC FIRE PROTECTION/SECURITY w oF�zQaaa�z �a ALARM BOXES AND CONDUITS SHOWN ON POWER PLANS SHALL BE PROVIDED UNDER THIS 1r aaaoava E��wo�w C) O O O O O O O O O O O CONTRACT. IN ADDITION, UNLESS NOTED 1 2 3 3.4 4 4.5 5 5.5 6 6.5 7 7.5 8 9 APPLY: p w�� o ^ 0'¢<oo� OTHERWISE, THE FOLLOWING GENERAL NOTES nSw Y�c�ooro w �w� Z 3U6�4wiW a000�0 ~ ZN(LO JQJ WK4 Ga ZQ j KZ Z O�wFWWwa p OKw A. ALL ALARM JUNCTION BOXES SHALL BE ¢ s «"''aal-V awa J a ka�z 4"X4"X2-1/8" MINIMUM. tl maVwnw m�si&www I # B. ALARM RACEWAYS SHALL BE 3/4" MINIMUM ~ gwo�<Ozwmu 00 j f ? WITH PULL WIRE AND INSULATING BUSHINGS. �' "Za 4QNQrcrca C. VERTICAL RACEWAYS FROM ALARM BOXES i SHALL BE EITHER CONCEALED INSIDE WALL =)OR SURFACE MOUNTED (TO - 1 i i MATCH JUNCTION BOX MOUNTING). ALL VERTICAL {O� RUNS SHALL BE TURNED 90-DEGREES AT �W 1 ( 1 3 I ! TOP SIDE OF BOTTOM CHORD OF BAR JOIST W W AND EXTENDED HORIZONTALLY TO A Z z i I LOCATION ACCESSIBLE BY VERTICAL FLOOR �� � TYPE LIFT. z W= z� _° 2 I i 5. UPON COMPLETION OF ELECTRICAL � ! r I ; CIRCUITATION AND PRIOR TO ENERGIZING o 1 A. INSPECT WIRE AND CABLE FOR PHYSICAL p I WP, WR, GFIi DAMAGE. 3 I j j 16.223 I I B. PERFORM CONTINUITY TEST. E2.4 ��i � I--iI ' C. VERIFY PROPER PHASING CONNECTION TO ALL I i t _ _ — j _— _ -_- _ _ � THREE PHASE MOTOR LOADS 21 KEYNOTES I �3m Y} n i 1 i 1 j 1 (' o - LJ 46 I i 16.222 MOUNTING OF CABLE TRAY: CABLE TRAY TO - - - - -_ - {j 1 �.' BE MOUNTED ABOVE BAR JOIST. WHERE C!!=9 i_C) Q PERPENDICULAR TO JOISTS, UTILIZE TOP OF W I T E (i ��-- i(( I RECEIVING I I ;rte`, \ E2.4 BOTTOM CHORDS OF BAR JOISTS TO �� JOISTS, UTILIZE UNISTRUT ASSEMBLYNo SUPPORT TRAY. WHERE PARALLEL AS0 o O 2 i`.` u ` & _ `u € NECESSARY TO SUPPORT CABLE TRAY. Z GE2 '1� I ' , j _ 1 I 111 { (S I +s_- 11 r [ € .. 1- COORDINATE CABLE TRAY LOCATION WITH ' —J -- 4 L1D1 '` 1 ' ' ` " �- " STRUCTURAL SUPPORTS SO THAT CABLE Q L>J ------ -- �__-S - F , .fi 1 i ' IG s 0 4G ---- - - - - - - - -- - --- - -- -- - - - --- - - H TRAY DOES NOT HAVE TO BE NOTCHED FOR €ten --_ _ - --- -- - - - - - - --- - - --- - - --- -- - - ----- - -- X-BRACES. ADJUST FINAL LOCATION AS ------ �.�. --- - - '._-BUSWX�Y-BC1'1C �- + -- - a � o L---a :�-- I - - AND POWER FEED TYP 41 ^' _ t t � - NECESSARY IN ORDER TO AVOID INSTALLING r- - - -- - -- - -"' "T-" ''`- --- - " - -'- --" `"- i L1 D2 - CABLE TRAY DIRECTLY UNDER SKYLIGHT - --- - ----- - - -- ---I ----- ---W�(- "-� j { I WELLS. COORDINATE ROUTING WITH O � 5 ri 24'-1" SPRINKLER PIPING IN ORDER TO MAINTAIN oI E3 J, 3'-0" MINIMUM CLEARANCE FROM ALL w SPRINKLERS. t Ii D1 1 Z I L1 � III �� 16.223 JIB CRANE- MOUNT RECEPTACLE TO - -- - - -- -- -- - -- -=- �= -- _ ----- -— -— 00- -8 Y-E ---- -- -- - ---=- R - ---- -- ' --- -- -------- -- - - - -- - - - - - (� j GUARD-RAIL STRUCTURE. ROUTE CONDUIT -� yy5 ,- AND POWER FEED TIYP FROM RECEPTACLE ALONG GUARD-RAIL o --- Y - } STRUCTUREAND PENETRATE WALL 2'-0" HYBRID E N j j I BELOW ROOF DECK. (3) #8 AND (1p #8 GND = J i 16.229 AIR HANDLING UNIT IS PROVIDED WITH A i I I I ISSUE BLOCK { I -- COPPER IN 3/4" C. i i , I { i i 8'-10" DISCONNECT SWITCH AND GFI DUPLEX lot FOR CONDENSER POWER L --- ! ' -- - y 38 RECEPTACLE- II .do I o� ����L y� 16L18 + ; L1D2 lj 16.230 PROVIDE NEMA 3R 12"x12"x6" HINGED, I - LOCKABLE, GASKETED, JUNCTION 80X i MSB 6 �� �� �� L� JJ ; j A ? I 1 a) (HOFFMAN # A-1212CHNF OR EQUAL) 1 2 CONDENSER C i { I 1 MOUNTED 24" ABOVE SIDEWALK. PROVIDE j _- SIMPLEX TWISTLOCK RECEPTACLE, SIMPLEX f # nl ; I ! {( IG TWISTLOCK RECEPTACLE, AND f, - - --k�j-- 1 oL'o r---� a , I' �I - - --- - -- - - - VOICE/DATA JUNCTION BOX INSIDE 33 F 7 1 '. I f 1 1 I 1, L i CONDENSER CONTROL WIRING: � �1 � I i I 1 � ENCLOSURE. PROVIDE FEED THRU GFI PROVIDE (6) #12, (1) #12 GND IN 1/2" C L--- ! POWER ,�,; � USWAY BL1C FROM HYBRID HOUSE SAT. COMPRESSOR AND FEED DEVICE (LEVITON #6490-I) AHEAD OF EACH i t I ? ? RECEPTACLE. I L _Ji [ 1 ; t PANEL TO VFD PANEL AT CONDENSER (3) #10 AND (1) #10 GND COPPER IN 1/2" C. ! ii ,1 HYBRID 16.233 ROOF TOP UNIT IS PROVIDED WITH A HACR JJ8 FOR CONDENSER POWER RATED CIRCUIT BREAKER AND GFI DUPLEX PROVIDE (8) #12, (1) #12 GND IN 1/2" C. j HOUSE MIB ; 5' ; RECEPTACLE. FROM HYBRID HOUSE SAT. COMPRESSOR 1 ; L��� " (I PANEL TO JUNCTION BOX AT j GSI DUPLEX ;(3) #12 AND (1) #12 GND I� 16.234 EXTERIOR SIGN POWER: MOUNT JUNCTION CONDENSER. ; t RECEPTACLE FURNiSHD -�J COPPER IN 1/2" C. I ! I # I" BOX(ES) TO WALL IN CEILING SPACE 6" ' u WITH EIQUIPMENT TYP CONDENSER B J FOR CONDENSER POWER SALES ; i ; J 16.0222 ; BELOW BOTTOM CHORD OF BAR JOIST, TYPICAL OF 3 HYBRID HOUSES. REF HYBRID ! 3 /i ; UNLESS NOTED OTHERWISE- COORDINATE mmmmm-- - HOUSE AND CONDENSER EMS FIELD R oi I H Ar---i i I LOCATION OF ACCESS DOORS AND PROVIDE CONNECTION DETAIL ON SHEET REM2 _ I m 2� , FINAL POWER TERMINATIONS- REFER TO m ARCHITECTURAL DRAWINGS FOR EXACT SIGN HYBRID � � I I � � I ' � i � LOCATION(S) PRIOR TO INSTALLATION. I �� WHERE ELECTRICAL CONNECTIONS FOR r , I HOUSE LTA , 0 ` -,F jTW2 j i CHECKED BY: i _ i 1I SIGNAGE OCCUR ABOVE ROOF LINE, PROVIDE ---- ' -- - --- ��-- - OUTE-ALONG-Wf-TH ---- ; - - - --- --- - - -- --- -- - -- --- -- - - `- - -- - - -- - E UNISTRUT TO MOUNT JUNCTION BOXES TO DRAWN BY: 11C -- - -- -------'--- SG $--- --= -- ----- --y--------��- i -4'-------- i I CONDENSER A I REFRIGERATION PIPING. i ¢ — BACK SIDE OF PARAPET AND PROVIDE ONLY _ ; i FINAL TERMINATIONS I MSB ONE PENETRATION THROUGH THE ROOF. REF FILE NAME: E2 -` BY R.C., TYP ARCHITECTURAL EXTERIOR WALL SECTIONS A R ? AND WHIP DETAIL FOR ROOF AND PARAPET PROTO CYCLE: 012712 ! PENETRATION REQUIREMENTS. Ll �� i r I r--- -- i _ DOCUMENT DATE: 041012 16.403 MOUNTING OF TRACK BUSWAY: WHERE PERPENDICULAR TO JOISTS, MOUNT TIGHT J TO THE BOTTOM OF TOP CHORD OF BAR i ® I JOIST USING 3/8" THREADED ROD AND FURNISHED t 16.229 HANGERS SHALLNBE SPACED NATRA MAXIMUM 'yyt OF 10'-0" ON CENTER. WHERE PARALLEL -- - - -- - -------- _, - `-- �;- -- i - --- - — - --- - ---- -----�-- - - -- - --�--- IR --- ----- ---------- ------------------ - ----- D TO JOISTS UTILIZE UNISTRUT ASSEMBLY TO MOUNT BUSWAY TIGHT TO THE BOTTOM OF �m�s�s�_e� �€ + THE TOP CHORD OF THE JOIST GIRDER. COORDINATE EXACT LOCATION WITH ------- E T J= STRUCTURAL SUPPORTS. COORDINATE I j I ROUTING WITH SPRINKLER PIPING IN ORDER PTO MAINTAIN 18" MINIMUM CLEARANCE FROM ALL SPRINKLERS. e I i AO R I3 j 16.611 UNITS WITH SMOKE DETECTORS: PROVIDE NP 3/4" CONDUIT FROM LOW VOLTAGE WIRING 16.233 - - - - ---- - _ - ---- ENT, DOWN THROUGH ROOF CURB. TIP 16.611 r---I 29 I -� 1 �J TYP i 1 , BL2A �-- GE2 E3 i i I 3 i i 117 L# 8 1 i BUSWAY BL2A TYP , (- -� L2B AND POWER 16.403 i > i FEED TYl3 ; It s {r{; iI jf 1 9 30 I " 6 �ay0 pRofp 1 ! �1 - 24 ' BL -10" BL26 f c�5� tiNGINE 9/0 - € �_�yo 1 i 1 BL2 72336PE < - -_- o BUSWAY BL2U AND L2U i N j I 2 ti ep POWER FEED TYP 1 I I I z• . ._ - o` O N o - - — - — - -- - - -—-—-—-—-—- 24'-2" ----- ----- , - - - I - -- =----------------------- d� ; o2P��i e. ------- A R - A R-------- - S AND POWER FEED — 25 — p L2B I S:A6/3� 13 ------------ IL Do3 -R a �_2D1 16. 34 �` 30 � ' -- ----- - — -— - - 16.2 - - ---- -- - - -- A- - _ I J J J J J J J -- --- ------ - ----------- -- -- A.3 N L2D1 t € _ - - g lA CONTACTOR , 18 4 EDC2 s = 1 M` I J r- e -� I C1 REF 1-E4 L_D1 ----- -- - s !-- --' i 2 WP, WR, GFI, +24 ,1 !! 11 r 1 11 11 1 i 1 YNP, WR, GFI, +24" s �, E2.2 12 1' u I i J 7'-11 5'-11 5 -7 I - 1 12D1 11 J i tl 1: I E2.2 3'-O" 3' 9" 2'-5" POWER n — — I PLAN 2 { 1 ( EXTEND DATA BOX CONDUIT i6�D1 Le �,- I I E2.2 - - - - TO ACCESSIBLE SALES I ! 1 FLOOR CEILING PACE i 3 I 1 1 WP, WR, GFI, +24" , 1 I E2.3 1 TYP OF 2 , i i 1 i i i i { S f i11 POWER PLAN ' ' ' o1" = 20'-0" SHEET: Q E2 0 POWER DROP SCHEDULE 4 5 5.5 (:D (D 05.25.01 ES01 -- -� NO. DESCRIPTION 1,-7" 10'_10» 10,_4„ 5'--2" 11'_4» 7,_4„1 ,_5» 6,_1„ 1 ;-4 7,_5„ 7'_5„ 7'-5„ 6'-4„ 1, 1„ 7,_5„ 7,_5„ 7,_5„ 6,_8„ 70-5"» 7,_5» 7,_5„ 7'-599 ,_0,,, 5,_59" 7,_7„ 5'_7„ 6,_5„ MOUNT RECEPTACLE(S) ON TOP OF 6..-..+.,_......_ 1 '"i..., a t '_."' ...,...._+I .» Yf .mow....... ......T ._,,..._.. ....,....q..., _ ,_...............».... , . . .... .. .... ,.�� ..... l t DISPLAY UNIT(S) MOUNT RECEPTACLE(S) ON BASE OF BL2A " I BL2A - - —. I I .I; {� j }t i _ _� .. I w- � BL2A �' ► + ii .. ° ! �I i _.__�__..1_- __._.w.__ .__i PD2 DISPLAY UNIT(S) 1 day 1 I I 3� r ��� ! 3 �.° t1121 23 � �° i � � i, ( F ! a �, 4 � � r ., .. ._..M..__._.� 1 „ 3 f ! 3 ! -- - µ PROVIDE DIRECT CONNECTION TO ; j 1 i G " PD3 c 5 ` , 35 y f i - ° 'k F4 j _ ti 3 �: I _ :.9 I i { 3 i ._ I��M i EQUIPMENT MOUNT RECEPTACLE AT BAR JOIST AND r i f ! r E a 9 r a d t i ; „ ° PD4 }«. ,� _ _ ,.. Yr. ,, �.. +:�.. _� a.wr,. _. I .w ° g _4 �.: �; ;w _ �: �. ...._. F i R INSTALL FURNISHED CORD REEL cmd. ,1 u7,a ai x ,'.du.�.... ..0 J J J J J J -, �'._w ...E f s BL2A i ! ' BL2A; ' ' BL2A s �... �_ E - i x r ! i i E ; I I i ; _� a c ,BL2A t y € ! i i , i 7 r E I t ! 13 € a ► t 2 t 1 f k 10 I .:J 'Er9 9 , I 1 15 ! ° r 4 ! I 12 1 t BL2U f a d --°-i C7 I C� ! , �.�0. ._�_ € Ln—L.� _. ._.+ w _ � . _ r I L _L ; 11 p t r ,° i o POWERDROPNOTES , i "I 9 i , , 10 �w,.... � �..__'_�,� E �i� ! �- � '�� M�'15 R �� �� � � � �•_ .k 4 � I r.......«.,_l� x I I...._..w~.,+r I ! � _.. 6 TYP J I '�, ° ' � .� i d i „� j ' I � j P E3 �' J J ,F 1 J J �: J J' i J J `` ,v J J` '�,, ' J J ` .., I 4 J J J J ... 1. APPROXIMATELY 60 DAYS PRIOR TO s h P y I " I I ' POSSESSION DATE A REVISION OF THIS w o oo} I t }r � k t` , � o y "a "^. ,d I�/'� w # 4 3 ti .S 1y �,y 4 ? >� 4 ( A a t 1 1 x f �r Q Z Z< �—• �...,,.... a...«,.o+'•" •"\n.....«%d"'' "'4,,,..w✓' Yl ....... _,.«.,.,w«.•..A •:•r',� a°,'` f ,•, ,f' "y +.r" : >,r .� r� r'.- ^^.. r'�' T"�`,. ,+'"r r 4h . 1 I : BL2A , PLAN BASED ON THE FINAL MERCHANDISE off—— zsW� o .,_.,.✓'"" w•.....A• -w._.,,•+'' "`^...,..w'✓ "*. ..A+''r "+�,...,�:.•,' •'iw_...w"" '" ^'' ^•,d........d•" '� +,,..,.�✓'''J'. t � CJ F-}c`0 1-N N!Y 6 10 7 3 t I C� �►-�aZ�o-,w�via,�0 ' I i 8 ! LAYOUT WILL BE ISSUED TO SHOW FINAL w opiEz¢aaw z �►-o BL2U BL2U BL2U r a o a 6m<w BL2U �,i tf LOCATIONS FOR THE POWER DROPS. IF � 0 }wo Ln.EL wc�0 w w Bw$ -, ._.. _wL .-, -- _ ..�ww�_ _� . _ w ___�.., «_,__ � n_ __.._.w.. ... �. �. _ __. ..._ N._ �.,� __.. _.; .. MERCHANDISE PLAN DOES NOT CHANGE, o mwNa�HF-xC,'->-jz52a 3 .. ...,...,,...,.,.................» �a.�.ltl'laihaYasF6ti[�.dHS.•N 0. N� (n W } y� THIS PLAN WILL NOT BE REISSUED. PROVIDE o� w wz�a.a a x I< J1A I cnt?w,twt-, x o.www� z < ,-z Oow Uo .�.- ...w_.�� kPD1 CIRCUITRY TO DISPLAY RACKS AS THEY ARE o 3�.rt ��w,y,�oo�o SET. IN ADDITION, THE FOLLOWING POWER cin. o a. W2rl 10 zv)d W a.Opp 03 DROP NOTES APPLY: aa�k'a►¢-Z��wcnv�oN� �zz00w wwwwa aw DOO U���� U-OWO A. POWER DROPS FED FROM TRACK BUSWAY: a NWow��I��o������ CHECKSTAND POWER PLAN THERE SHALL BE NO ADDITIONAL CHARGE F= - w 2 �� zo��dcwn¢�a¢R 1/8%9 = 1'-0" FOR DROP RELOCATIONS THAT RESULT IN A BRANCH CIRCUIT LENGTH INCREASE OF LESS THAN 10 FEET FROM POWER DROP TO NEAREST POINT OF TRACK BUSWAY. cN INSTALL FURNISHED PLUG-IN UNIT AT A Q� POINT ON TRACK BUSWAY NEAREST TO &AW E POWER DROP(S). agW _ B. POWER DROPS FED FROM PANELBOARD: Luz ?�� �� a THERE SHALL BE NO ADDITIONAL CHARGE 011111111111111 zYa w o FOR DROPS RELOCATED TO WITHIN 10 zo o d011 FEET FROM LOCATION ORIGINALLY SHOWN. Q WZ ��o ''� M L'i 2. PROVIDE JUNCTION BOX AND CIRCUITRY TO :�:W M NEAREST JOIST ABOVE LOCATION SHOWN ON � DRAWING. EXTEND CONDUIT AND CIRCUITRY o FROM JUNCTION BOX TO ENDCAP OF c) DISPLAY RACK (AWAY FROM ACTION ALLEY). 3• PROVIDE CONDUIT AND RECEPTACLE(S) AT E3 DISPLAY RACK SHELVING PER POWER DROP (D 2 3 3.4 4 4.5 5 5.5 6 6.5 7 7,5 $ 9 SCHEDULE UNLESS NOTED OTHERWISE ON DRAWING. VERIFY EXACT HEIGHT AND I ! LOCATION OF RECEPTACLE(S) WITH STORE Z I j ; PLANNING SET-UP SUPERVISOR PRIOR TO a i 1 i 'INSTALLATION.I , TI .-......_u,�.-,..�....-w..,_.w._..._. ' wm,. _.__........... .�..� ' ,�n. ..�..... �I� ,;"w.�_......,.w�� � a ��:.•--�•�.h i s �,_ . .,..� � � i..w � � i I!v STA��..A OIv. ..,.:..,:.. ,..«d.d ...._,ter .,. ., ....•_.:..,.+ ....+..,.».,...........,. ....,,+...................+.,... ..,.. ...w'i�..,,,.- .... :.l' ._......,.,..........,......_..._.. +...+_,_,.... �.........,_�,._...........,..... e -» ..,. ..:... , ...« .......<..._:....+.,......:,............,..,._......_ .W.......�.,.....,....«..,....,_........,a..._..•.........,_.,,.�:,._......,. C"..,:,2,Y............-...,,._.._,—__ ___ . .... kl,w..�E......,..0 _.. �:.r.......,... aar,>: '•..... .,,...._..,.,.._.—, �p�._ ..,,...._. ....»...:�;:.~ W...:, ..._�ara�.w•,.� �,�r,_�'�,:'�."�, Y"y,,�.�..�a''�„.� .�....,_._.......,.. _.+..�.... .»,. - _.E —.._...,......,.. ._...... _,. ..._ �.,._m..�_ _ ,,,......«.,.._.. .... _..,.w._� .:... .,_,+.+,.... ._.�........... .....:..._.,.... ..,._+ _ .,..._w._.... .,_ .............._ ,,..- ..:,...._............._._...._._ r If i 4 y(( pp (t EDC1 , 'I �� i � i ; �, , �,�� i . �, _._. ..._}. { I! I KEYNOTES Lc) O k..t.J ` 16.401 IDF CABINET: INSTALL RECEPTACLE IN a �`` ° PREINSTALLED JUNCTION BOX INSIDE THE ® � O s �,; j a t I ; ,;a, `'tkh • -� ;s, ��ti !•rrj w •., ! IDF CABINET ENCLOSURE. IDF CABINET E E�rE _ -----===_ , �..... � �, PROVIDED BY OTHERS AT STRUCTURE. "_i'ur����r_.a r:a._,.�,......,...:.T r � � � ��"ryia,c s � � E r,ti tir � `', D L D B LOCATION ISE s�! 1 + +. �; L� 1 r COORDINATE FINAL IDF INET LO ATI —_iy«y WITH CABINET INSTALLER PRIOR TO # r: � � i ' t � ° � ,c'A6ms�dnav,�uzfa� �� µ�x��'', �' dn1 �'[F• T�� r�j� "�uwem �ri,.y,. Y([ �`y >w.,..:+ �/� i ? a..+,:1 I 4 [ cMM q d d s'�, s , � y i i E i ee°-� �Ki ._ w. 4 INSTALLATION. o I° _ — } d �� ���� � a �� �� p ► ° �! �' 16.407 IPTV WELCOME OR CATEGORY SCREEN: �M=, :� :�.�� �,�a � � ,�� � � �--.•��t� '-� �-.�� . MOUNT JUNCTION BOX AT STRUCTURE. � "� AFTER INSTALLATION OF DROP POLE AND .. ............................ ..... .»,�:-_: ..,.........,,.»r. .... ...,,._�..„..d,.•"":.....+,....«:......... ,.,..„...w-+.,_�.....,,...,", -«',....:»...�.`X._......y�».. w.».,..�...,.:".;:=.".,..M.. .» ....�..�,� i d,,,.. � � '°..,4, � +�', t�a U�� � „� f! g. �t �� f�� S�9 � ...... �¢ , ! TV COMPONENT TRAY, EXTEND CONDUCTORS "'� w +,mvm..,wn r... d++n KnkeM„Mdn,nrt. M„Yi4,Ml+W 9. ii MN' ,taF^.SkC.' ...K 9.' . dT" • Y T. i. p i e . .. «.ar`.nn ,w.ww n a „ u.,rt •fi k:T2H r cnm M M,.nA,,.+ ..... w...,-j)r .: ,.�.!.,« .,f'r�C�. d'.,,_«...•... ..•n._w.+ n.....«m..Vi,. .•Lnv 'S n«:sl..+,.dna 1„ ..�.a `F(yt.4._.. ... . .. .,...,.... .:...�....,....,...,,.. ,...,.,. ..«_......,......,.......................+...........:._..:,..........,_ ...r ...... .... ......+......,�+.... ......,..,...,.,,.,...,....,.,.,..:...,....,.,..... .................. (.,mT!.Mn,S. ..........F•t!C _. M.n�' . •,rlll►�11Mr.. j{ •1+1.„ ,SII, VMr► 4S r { d M wt ...•w...,.. rwr ..,......vn.....«m.. w:«...+.:.. w,r...,.:.._., ,.w. • �w•... w+ „ ... ..J ....�«._°i.'"d."�.,..'._.... ._.....",'J...._"....�,- ..SSS...+F:";.,,. .:1 ,,.. .. .i4MINC.. .. .. ._��.WM�MIfS.AIgMAF'�'".41MIF�MMiM!I°f... � �MiM►ZIIMulY�1'!M�M+R�SI 'MM1MF:�"MMM�M+Ys•.. .. _ Xt � �'4 4 '� •. OD"�+„T,,. ....(�"`" .E�P.91r1�-.. .. a .. :M�MR"A .. .... ..'ar+..K.. .. ..............'1".:..-'�'.,..__1.."�7G..M�... �..«is,. ��,C.._....�......... ia^._ ....._.»_«....:.;a.,._,...,•-'a.."=...:S!"`'?rn.._d..k3..._."F3~'."_....._......,-{..._..:.«...k.t!?...:,._..�Tt�'......._...�..1.'%'tSCN"�-:!�.....E;'�J,'A1'.�^[T4.z:w..'�+JXc"..N.....tv.........._:'G*.�1."��M.".",.«""1,2t",.;S....":".;.G.,,..«....k::Si.. i I IN 1/2" FLEXIBLE METAL CONDUIT, ROUTED INSIDE DROP POLE, TO TV COMPONENT BL1 A 2 11 A TRAY, TO MAINTAIN NEC REQUIRED z .. .. _. .. - r.� w.zr3 s_a:t a w 1 a....� ru.a• ,..ar ._, ; o PD2 is`4 SEPARATION OF POWER AND DATA. PROVIDE C ��'s I ��.•_ �lx„_�,,.�.,.,�.. ���I I 'I f � �� � � I i � � � '+,Sy 120V 20A DUPLEX RECEPTACLE AND FINAL o r TERMINATION. EXTERNALLY ROUTED CONDUIT -9" II AND EXTERNALLY MOUNTED RECEPTACLE � ' '°.. WILL NOT BE ACCEPTED. COORDINATE Is f N { 4 ` '•.mWvpa:xa.�+N'AcT: �A >.�hw,. t iL ,;n LOCATION WITH IPTV EQUIPMENT INSTALLER. ISSUE BLOCK I:"(, � , � I '� �, 4 16.408 IPTV SYSTEM CONDUIT: STUB 1 CONDUIT �.�+.�'.�"�.�� `�. �"�'�' w .�. �.. :�` ,. � � �j � � � J 17 � � � PRICE # S M. rmem i 16.408 OI I I12A 1 ? k (WITH PULL WIRE) FROM BELOW SHELVING } i I VERIFIER, UNIT TO BAR JOIST. PROVIDE BUSHING AT 15 PD1 Q E 19 -8 �� ! BL1B J +60" 10B EACH END. COORDINATE LOCATION WITH J 12B -�-t` F - -- --�-- �� a 9 BL1B 13 0 I +96" IPTV EQUIPMENT INSTALLER. s PTV 17 I f 16.409 IPTV ENDCAP SCREEN: MOUNT JUNCTION �7 I TYP OF 5 BOX AT STRUCTURE. AFTER INSTALLATION 3 ? 6 -5 1 15 j 16.401 1 F OF DISPLAY RACK AND TV COMPONENT I �-+- __.. ;.._ 1 +16.409 , 18 i 1 alyy{�� � �f� 13 �c ISI , ; -- i 1 IDF TRAY, EXTEND CONDUIT AND CIRCUITRY _ ►BL1 B i IPTV i i BL1 C 16 w I ; E FROM JUNCTION BOX TO TV COMPONENT 9 3 2 i PRICE i BL1 C TRAY. PROVIDE 120V 20A DUPLEX I PRICE c� 18 N N IDF � r z ; S t Ik a ; VERIFIER, iE2.3 E2.3 E VERIFIER, 05H ; �.� �= .+...:' 1 u 1 +60„ 201-3*' >. PRICE CD +60 0 1 0 x !� RECEPTACLE AND FINAL TERMINATIONS. I� �. - �;'; - _ rn 9 a VERIFIER, i 6 t t I , +60 0' 1� `B�1.�.. � �5� 0 9 C I f� COORDINATE WITH IPTV (D IPTV �+-►BL1 B 11'--8" Ic ' OgA L1 C BL1 C PD2 EQUIPMENT INSTALLER. 12 , (jkrk` 16.409 3 1 i O J 1` n! 11 20'—2 i PRICE J uli -j i" a VERIFIER, 9 to 16.408 +60" 3 1 BL1C g'_8" 9 77})l) t A H y �rb�r�crtav�a:ax::. rdratre�e�xr i � � � i � r L_j, C14 -7 CHECKED BY: v' 7 e yl DRAWN BY: TLC ti; N t ; 3 9 k , ax ' , '„ FILE NAME: E2.1 PROTO CYCLE: 012712 r' �•- a = t( DOCUMENT DATE. 041012 To I r 16.408 r � all i jai : J a AIN I IPTV 1 w. 33 16.407 i L1 D3 it I � �;. I L1 D3 92 4,L 5» 7I d 10 BL1C`4w alloil PRICE c If 13 —10 c " ! I 14 _I 6 TYP ° VERIFIER, I PRICE 1 ! � PRICE _-,_-- 1 ° ,✓ ,, VERIFIER, �� +60 i V RIF .� �R d,�..� �. °,�f I O E VERIFIER, J o - - v �- +60 _ w_ _. - _ ___�_ ___--___ w- 34A 1 ,pr t _ �c ws mx sty a�anca,ra mma wnn sag" �— a g �� B L 1 C N I$ 1 i J N g J �' o 1 J '• n � co GROCERYSALESPD3 i 18A, PD2 �I i � t a 2 TYP OF 3 a 16 n „ r ? 1 -6 I BL2A 2 - 07B 07A PD2 I BL2A .� . 99-71' a 14,_7„ PD4 y TYP OF 3 i 1 J J 11 o PRICE <11ir °: °" � o � 32A0 i VERIFIER, E � -• -- I v- 4 � _ 1 i oo i I +60" II to to i r !DF oo n I I d PD1 35 I u PRODUCE BL2A 3 2 i I .* ( tt •' 32 15 -10"I t (�PRS 1,: r T� �r i r I w r, » �,_n» n T- ! 34 Opp ��+ M.S,.Rs , —9 r 36 IDF t �r BL2A E-2.1 j i� B LG A (0 1 r � " � ,� ,... , L2D3 SYSTEM aI �, �BL2A ----- BL2B— e' 23 J 8 _3" I B L2B s 725 �'� 13 -11 1 IDF 10 a 8 BL2A 1 12 , N 16.407 31 J B 28 �'";� E3 2 a IPTV � l � !PTV I ►" �� OREG � ,Lo • I 40A 16.409ay ,, 1 g PD2 J : 16.408 5'4-5" 9 -7" o0 08A : = M,. .-._. _ _. .. _ - _ r _ _ _ ..._ .. _w.~.- _ _ _.�... w r I. RES:86�38/2A1 I . ,Y LR - .!L� ,..,��� ..,� •.�..___. - -------.. _ PRICE _ .... - � .�....- _ __ B ----------._---__-------.«....__---_--r ,�..._-_-_----_-- + _.wr__-_. �._�___�._ -_.-_____�_--- ....�_ �.- VERIFIER, , li$ t7__ '� f �igmti �smw , +60 BL2B + s, i � `V Add•� G ✓ �� � � � �tk � F_ ry, a �..Fii� W,�✓��"'�� �, ��k��'7's'?�-�=��e�� �k"'..� I"�'�'."^9 Z � � � � _� � 1 «tlE� f . � t r I 13 5 d� b�e � 3A. r'+,, f ..«.....,m....v_.,..,,. � t �� ��� a �a,...f � k�'1r�� a5v>Tip 7r�- nig'� w� � � �! iI;2E ,- pr91', -t r,; ,! qq :, 15 17 "4a�'�f !� i* i � A, ..._..........,.. _,.f } �d{ry"aa.:d ::1s``�,,;i,"'+a,: ll� ' iiel 3r'•� M Niaprr»................�t 46E, PD1 9 EDC I '�, �"° TYP OF 4 J qpy f vea,ua nmva+ -�J : .. .._. .. d _. --p.- ,._. _. _. _ ._^. ._._.__ _._ _ _..._ _ _� _ — .___ _ .. __- - _� - r} fi5 0 POWER .a-a�ammaam, r,,• .� LL •"«'- �.�a.mr�cL __._ d R ...w i+E.«,+,.,. .. ... ...: »., u_, _w+. '_. _ �k "a� 9-- - q�;h- "� J !u� _ DROP 7tz PLAN a E 1 i i 9 BB BL2B _� it ' ,wd:4 . 6 _ eGPah^.k��T"" � " "�4m�..}�p "R N79"fS���Q'Sm. S j u�..�.as a .�•.�»+ m ...a c .w 11 E tlzg i( I ? �. _ !y y�'` r.,,,.Lw✓ ° r,« P 3 3 4 } i �'""..._........ ..w....,......«,,..,.Q.t..—».,...,+.�....ln_.+..:.•-.:.«...-+-lW t { tl �� Y Lu Q _- POWER DROP PLAN. SHEET: 1" = 20,_0„ Q E2 * 1o KEYNOTES 16.220 INSTALL PREFABRICATED ELECTRICAL 16.606 PROVIDE THREE RECESSED ALARM JUNCTION DISTRIBUTION CENTER (EDC). EQUIPMENT BOXES (NTH ONE VERTICAL RACEWAY), ` 2 / 3 AND INTERNAL WIRING ARE SHOWN FOR INSTALL (2) BOXES +52" AND (1) BOX ��/ 7 s INFORMATION PURPOSES ONLY. THE ENTIRE +48" TO BOTTOM OF BOX AT 10" OC WITH ASSEMBLY WILL ARRIVE COMPLETELY 3/4" CONDUIT NIPPLES BETWEEN BOXES. ? PRE-WIRED AND IS AN ETL LISTED 1 +96" //j 4 ASSEMBLY. 16.618 FIRE ALARM BACKBOARD: PROVIDE 120V t 7 ` f 16.226 ELECTRONIC ARTICLE SURVEILLANCE SYSTEM: CONNECTIONS TO FIRE ALARM BACKBOARD 1 2LRC Iff `` PROVIDE 3 4" CONDUITS WITH PULL WIRE) EQUIPMENT AS REQUIRED BY BUILDING FIRE / ( ALARM INSTALLER. COORDINATE EXACT FROM EAS POWER MODULE TO EAS PROVISIONS WITH FIRE ALARM INSTALLER I ! PEDESTAL LOCATION AS SHOWN ON PLANS, PRIOR TO ROUGH-€N. it -- 1 a p LhtC 1; INSECT ( WITH OVERALL LENGTH OF EACH CONDUIT 16.619 PROVIDE RECESSED ALARM JUNCTION BOX j � " `` " ° g f " 4r i CONTROL WP, 1 I NOT TO EXCEED 36'. STUB CONDUITS 3" / f IN CEILING WITH 4"x4"x1-1 2" EXTENSION " y,. .. , - _- _ _,--. L 6'i' 411 ♦If' G/ iil L LOCATION NAND DEXTEND CONDUIT UP D WALL RING WITH RACEWAY ROUTED TO NEAREST ' � � GFl, +96"� 2 CONDUIT WITH PULL T I LRC RC LR• f ( _L - lRQ - LROb LR f -.LRQ . -1 R -LR ',' - ACCESSIBLE CEILING SPACE. I1 t r- TO THE HEIGHT OF THE EAS RECEPTACLE, WIRE) FOR DATA CABLE -� 10 7 1 25r - 31 37f 32= 38 - - s J EXTEND 2" CONDUIT 1 PROVIDE BUSHINGS AT EACH END. 16.621 PROVIDE RECESSED 4-GANG BACKBOX (WITH ' --- 3 EL 1 ! 1 s I " I S-0 1" CONDUIT FOR 120V - J L2D2 TO BAR JOIST IyP c n` ON VERTICAL RACEWAY) T +52". w N o Pz� - LR i { f 16.232 AUTOMATIC DOOR OPERATOR: VERIFY AY) Er;: <2 wo CONDUIT FOR 120V LG. _ _ ala-__ _ _._ 15.2� „_ _ _ _.-_ __�- _. - _ _ _-. _.- __ __ -__---------+8q _ _ LOCATION WITH MANUFACTURER'S COORDINATE EXACT BACKBOX PROVISIONS � ✓I - -- -= = --- - -- -= 4 WITH FIRE ALARM INSTALLER PRIOR TO "- - 1 +84' �- EF ( RECOMMENDATIONS PRIOR TO INSTALLATION. I LRC 16.232 1 ALL CONDUIT AND WIRING SHALL BE ROUGH-IN. a< woom E��w�o ow i TO REMOTE 8 O � y oNxo�zma> 16.601 li UTILITY BOLLARD 1 NEMA L15-20R +84" CONCEALED AT MAIN ENTRANCE DOORS. 16.622 PROVIDE RECESSED 4"x4"xl-1/2" ALARM i aN���N4w�Wz �<t ! PROCESSING ! I RECYCLING TYP OF 10 ' Now���o�r aw w� I ? TYP OF 3 % 26 (� 16.2421NSTALL MANUFACTURER FURNISHED JUNCTION BOX WITH VERTICAL RACEWAY) z 3LLzopww000 w� ;11 CENTER 12 s JUNCTION BOX CENTERED AT DOOR HEADER AT +52" WITH 4%4%1-1/2" EXTENSION O wgow rc�Uo�azo< _ , 7 7 C ,H zma �a w�e� oa J ---------------------- 4'a t LRG FOR SECURTY CABLING. PROVIDE 1' RING AND 4"x4" TWO-GANG DEVICE RING. ¢ s m wo_ao F wa L_- _ ({ INSTALL MANUFACTURER FURNISHED JUNCTION BOX CENTERED 3.AT �<1u< �w 5"pzN� I { LRC 1 DOOR HEADER FOR SECURITY CABLING. PROVIDE 1" CONDUIT 1�ITH CONDUIT (WITH PULL WIRE) FROM JUNCTION O g=go=w �wwwo gw € ( . 16.651 AP OFFICE CONDUIT: PROVIDE 2" CONDUIT a o wm Fu ow INSECT I 6 I i S BOX TO STRUCTURE. TERMINATE AT BAR - Nwp o,-w 1!2wo5umw�� __ _ _ _ __% __ PULL WIRE) FROM JUNCTION BOX TO STRUCTURE AND EXTEND;TO _ FROM 6" BELOW CEILING UP TO BAR JOIST, ~ _N �o"-aozw�wwoo 33 CONTROL WP, - --- - - - - -- - -i - I JOIST WITH BUSHING COORDINATE =�5Nzo5a<m<¢¢<r i I- _ { - i I1 -I - 1 j ! 1 ACCESSIBLE CEILING. TERMINATE WITH BUSHING. COORDINATE TURN 90 DEGREES AND ROUTE TO THE TOP GFI, +96" INSECT INSTALLATION WITH MANUFACTURER'S REQUIREMENTS 1 INSTALLATION WITH MANUFACTURER'S SIDE OF CABLE TRAY WITH CONDUIT i 1 (I II II ! { a 1 ; ! CONTROL L i �! REQUIREMENTS. CONNECTOR AND BUSHING EXTENDING NO z)m _ _ f +72 LAMLi f { ! t L + I H 11 L j i i 16.410 COUNTER MOUNTED DEVICES: STUB OUT OF MORE THAN 1" OVER CABLE TRAY. H - -- WALL AT +8". ROUTE FLEXIBLE METAL TERMINATE WITH BUSHING. ey-= - ---- A __ _ _JL -- ---JL----Jl- --JL- _ I _JL_----� - _ 3 1L H� -- - CONDUITS ALONG BACK WALL OF CABINET. ! L MOUNT DEVICES WITHIN CABINET AT +8" 16.659 CONDUIT SLEEVE: PROVIDE 2" (UNLESS e NOTED OTHERWISE) CONDUIT (WITH PULL am W UNLESS NOTED OTHERWISE . EACH DATA Z BOX IS TO HAVE A SEPARATE CONDUIT - ( ) WIRE) FROM 8" BELOW CEILING TO 12" Q I 1 r 7 -; r E r BUSHINGS.CEILING AND TERMINATE WITH z W Y o it +( 11 ROUTED TO 12" ABOVE ACCESSIBLE CEILING ! _� � o = --- i SPACE. VERIFY LOCATIONS WITH STORE J =W m W G € ` ! PLANNING SETUP SUPERVISOR. 16.661 DATA AND PHONE CONDUIT: PROVIDE { I s CONDUIT SLEEVE THROUGH WALL AND 16.600 PROVIDE SURFACE MOUNTED ALARM ROUTE ABOVE BAR JOIST, UNLESS NOTED RECYCLING CENTER P 0 WE R PLAN JUNCTION BOX (WITH VERTICAL RACEWAY) OTHERWISE. ROUTE CONDUIT TO THE TOP o 4 MOUNTED 2" ABOVE AND 8" IN FROM SIDE OF CABLE TRAY WITH THE CONDUIT STRIKE SIDE OF DOOR FRAME. CONNECTOR AND BUSHING EXTENDING NO 1 16.601 PROVIDE SURFACE MOUNTED ALARM MORE THAN 1" OVER CABLE TRAY. JUNC11ON BOX (WITH VERTICAL RACEWAY) 16.680 REMOTE ALARM BACKBOARD CONDUITS: O ADJACENT TO AND EVEN WITH TOP OF PROVIDE (1) 2" CONDUIT (WITH PULL WIRE) 3 q DOOR FRAME. FROM TOP OF BACKBOARD TO TOP SIDE OF __- 16.603 PROVIDE RECESSED ALARM JUNCTION BOX BOTTOM CHORD OF BAR JOIST, TURN O 6 C f€ ( L2D2 HORIZONTAL AND ROUTE TO ACCESSIBLE L2D2 WITH VERTICAL RACEWAY AT +80" wIT,H •�• L2D2 L202 �g SALES FLOOR SPACE. PROVIDE (1) 2" =2 m 7 I ° ____________________________ t2B -3 '- -" - 4"x4%1-1 2" EXTENSION RING UNLESS a r 39 3 Rj WAlE12, / 33 _ _ __ NOTED OTHERWISE). CONDUIT (WITH PULL WIRE) FROM TOP OF ' "".. "" ) BACKBOARD TO 1 " ABO CEILING OR BAR f -=---------_ ----__ - +60" BAC B D 2 VE N G yr - - 1 16.604 PROVIDE RECESSED ALARM JUNCTION 80X JOIST IN AREAS WITH NO CEILING. �.J Lo ! INSECT ,n ICE BAGGER +60" ! p CONTROL, Dl ;� = till (WITH VERTICAL RACEWAY) CENTERED 2° TERMINATE CONDUITS WITH BUSHINGS. I f' - f ABOVE DOOR FRAME. O -F60", NO +82", CENTER1 ICE MACHINE -- .- .- ,j- a +16" AND € Es - ,f- ALCOVE -- a EDCTENSION _. ON WALL +40" STACKED =;v RING }` +48" {CE MERCHANDISER, +60 1 O 4 16.603 - i ;l r E MAKER, _ ---------- -- -------- L14-30R, +6 0" W 3 ��! c L2D1{� :A R = __ RE TER A TE SFOOD SSEOR RVICE - -tip U ~ 2 ` +84" o WORK IN THIS AREA q �{ - TYP OF 4 l j! 16.226 LJ 3 i 92" L2D1 -_j *--- -- _J i! C 35 --- - --- - _--------®-- - - -_ t 4 i= l i L2D7 +52", NO �� r 16 651 1 L2D1 t+36", TYP OF 3 VESTIBULE 1 t I r ISSUE BLOCK i 6.659 + O" 31 RH, tAT -- -_r�=- 19 EXTENSION r ! I 3" C 29 1 STRU RE L2D1 L2D1 v� ° + 1317 17 IL -----, t L2D1 (( --------------------------__ _______- 40 42' H if 16.6°21 L2D1 GFI I --- ----- ----- ----- ---------- - - r ?f 15 TYP OF 5 p --------------------------- -----=---- 12D1 1 I i 16.622 t � ( CART STORAGE PROVIDE ON/OFF it L`�$ �O 37D ( PROVIDE 3" PVC CONDUIT (WITH PUL 1 WIRE) � cn cunr� r�o i i #2 16.2`1'2 I J FETY J.., ,�H ,�! r i / TYP OF 2 1 1 BELOW GRADE FOR POLE MOUNTED A S UNIT HEATER ++ SECURITY CAMERAS. STUB CONDUIT +6" ABOVE CEILING IN AP OFFICE, WITH - - - - T --- -= L 1 AP BUSHING. CONDUIT SHALL EXTEND TO PULL t BOX, COORDINATE WITH CIVIL DRAWINGS INSECT I e = _j ; f L OFFICE ; I TYP 16.232 CNtOl_ t n ALL CONDUITS 1N GROCERY ENTRY AND;VESTIBULE +96" COORDINATE;FINAL LOCATIb1J ! t FOR LP, VOICE OR DATA LOW VOLTAGE CABLES TO BE 1WTH ' I ` 1 ROUTED TO THE ACCESSIBLE SALES FL60R SPACE PRIOR TWINSTALLATIONSALL�3 _ UJI 11 - 11 26'-1 r VESTIBULE POWER PLAN AP OFFICE POWER PLAN 2 1/8» = 1'-°" CHECKED BY- DRAWN BY: TLC FILE NAME. E2.2 PROTO CYCLE: 012712 DOCUMENT DATE: 041012 O5 5.5 t PROVIDE 1 _ ------- __ CONDUIT SLEEVE __ --------- ---------- WITH BUSHINGS ABOVE BAR 1-1 2" C -----------------e._- _.__________---,_----------------___----__._.. b,+90" N +90" JOIST FOR SUB-METERING 16.661 CABLES. ROUTE TO ACCESSIBLE .................._....-.....-..... ......_. - - --SALES...AR€A..CEIL4NG..SP•ACE..._.....--...-..............._........... -- -- ------1 `• --------------- ------------------------------------------------ ------ - ................_..--_.._.._.._..--- _. -- ......................_.........._.... ..._............ - � 1 L2D2 I 1A 4 COUNTING bL2D a RETURN L# 12D ----if i ? 16.622 STORAGE JUNCTION BOXES CUSTOMER t! s A A rt - PROVIDED WITH SERVICE L GF! �II MILLWORK, REF ((( 7 i 6.619 i a +48" +20 , SPACE ARCHTECTURAL TYP L2 ;i I? I ! I s - ( J 5" ON CENTER, TYP OF 16 ------ 48' STORE ANAGER S '. � 2 16.410 +26" T I I r� OFFICE OL2D2 TYP OF 6 L COUNTER, !iI ................: p��C_ P 'eH�s�O.a +48 76.62 ? ' 16.680 2 H2A EF c c c c c 1 1 c IS s i 72jS3PE I i S[ 48" A t A ; L2D1 L2D2 3 L2D2 L2D219 L2D2 Zay R ry q.6.604 J 4 L2D1 EDC2 NSD/M1 ENCLOSURE 1 16.606 PROVIDE PROVIDE 1" CONDUIT TO i ' V (- LPTV, +90 H2P1 FOR POWER AAA b,+90" SUPPLY CABLES RES:06130/2013 i 16.618 L213 H211 +1 SITE LIGHTING 1 - --- -- -- -EF-F-1--El --- - --- ---- --- -- -----+ ? --- -------------- - A.3 - -CASK- � _....................... . ....... - ...._......._..--.._... -...... --- -.....-------. ......-_...-.._........................_-.........,..........__..... +48" 16.619 IL2D1/L2D2/T2D/ TFS/LFS BRKR/ s CONTACTOR H2P1/LASS { 7 j 28 ' + i 1 ; y L2D 48" I Cl STACKED STACKED L2D19 30 l AVS t- 9 it 1 228 301 6 L2D DATA BOXES INSIDE THE 1 9D1 I CASH/COUNT ROOMS TO WP, WR, GFI, +24" ENLARGED TYP OF 7 POWER BE PROVIDED WITH AN r b 1 INDIVIDUAL CONDUIT I ROUTED TO NEAREST PLANS C ACCESSIBLE CEILING SPACE , ' SAFE t si r A.2 i i w Q FRONT OFFICE POWER PLAN 1 SHEET: Q E2 . 2 0 KEYNOTES O 16.227 ELECTRIC WATER COOLER RECEPTACLE: 5 CONCEAL WITHIN CABINET PER MANUFACTURERS REQUIREMENTS. 16.2281NSTALL RECEPTACLE IN PROVIDED DATA ROUTE PHOTO LAB CIRCUITS t ENCLOSURE. COORDINATE LOCATION OF IN SURFACE-MOUNTED RECEPTACLE WITH ISD CABLE VENDOR. --PROVIDE 1" CONDUIT FOR CONDUIT UP TO BAR JOIST_ DATA ND SCE CABLING COORDINATE CONDUIT CHECKOUT CIRCUITRY IS 16.4081PN SYSTEM CONDUIT- STUB 1" CONDUIT ��QQ JOtST AND LOCATION WITH PHOTO LAB HORIZONTAL PRE-INSTALLED BY } (WITH PULL WIRE) FROM BELOW SHELVING TO .�`i�E TE,Fx`1NINA __ WI BUSHINGS FIXTURE PLACEMENT CHASE DUPLEX RECEPTACLE CABINET MANUFACTURER. UNIT TO BAR JOIST. PROVIDE BUSHING AT « -------- --- -----------------------__ __-_e._-____________ ___________________- !I REF ARCHITECTURAL. EACH END. COORDINATE LOCATION WITH H - --- -- - -- - ------ ---- ------ t- -- ---- r (REGISTER) ? i IPN EQUIPMENT INSTALLER. IG DUPLEX RECEPTACLE DUPLEX RECEPTACLE GENERAL EPOWER 16.413 ROUTE ALL CUSTOMER SERVICE COUNTER - '� " 'L---`- ® -- - - -` --- -� "- ® ---�`-- TASCO PROVIDE 2" CONDUIT WITH gU}q I ( ) (REGISTER) I TIONARY FILL PRIN € CONDUITS IN FLEXIBLE METAL CONDUIT THRU COLOR I pi I IA RADIUS THRU WALL AND DUPLEX RECEPTACLE 1 REFRIGERATOR ; FURNISHED CHASE AT FLOOR. DATA, POWER �f PRINTE p GROMMET XT COUNTER. IG DUPLEX RECEPTACLE ! VOICE/DATA GENERAL POWER 3 4 1 P 25 { TYP OF 2 ( (REGISTER) (TASCO) I { DOCUMENT { I VOICEj/DA A / " CONDJIT TYP AND LG. CIRCUIT SHALL BE ROUTED IN 1 8L1A I 3 4 C 4VI PULLW!RE, SCANNER 1 I VOICE/DATA SEPARATE CONDUITS_ REFRIGERATOR 16.452 SOUND SYSTEM CONDUIT: STUB CONDUIT w zQ 1 p ! { I { LASER PRINTER I y ooY 1 p WIDE FORMAT ! 1 TIP OF LASER PRINTER PHO E0 PH E� f GENERA I POWER to ozr� aizww �m� p 22 P UPS CCT b -` --VOi DATA (WITH PULL WIRE) FROM BELOW w cF a <ao�" z-z - PRINTER I ( ! k LRX-2,10 / SHELVING UNIT TO BAR JOIST. PROVIDE QaNa�g I !! LRX-2,10 P P _1 LRX-4 I . LRX-6 ® ! "�� I B If W Q a akN�w> -Q�ywmom 1 BUSHING AT EACH END. P t I CP _ CPU CP N t I CPU PI1 ? 16.612 PROVIDE RECESSED ALARM JUNCTION BOX allo��N�w�wi �a yVw�m�Om dW w� SP UNITo P- t P� � - ! °j � I � '1 I � � , I 11 j (WITH VERTICAL RACEWAY) MOUNTED 2" z aa<zoow oc~+o w HP STATION; P i 3�< w'wwwmao�a 2g �/ t UNCTION BOX FOR ( I } I o wmz oy z oz cv I d { ABOVE AND 8" IN FROM STRIKE SIDE OF oaoow�oo'o° az a p BL1A { ! JUNCTION BOX FOR TERMINATION (TYP 2) _ _ — DOOR FRAME. ¢ z "I{{,�m°-, 'aomF¢a3 Jr J Q F-ghm l ~V2NJ { p TERMINATION TYP 3 JUNCTION BOX JUNCTION BOX < I-"crzF mmo�o- i 20 ( ) IG DUPLEX RECEPTACLE 16.616 PROVIDE RECESSED SWITCH BOX WITH a 000 wu=�mz° � owo DL 1 { FOR DATA FOR DATA 1'-10" 1'-8' 1'-10' 2'-3" 4'-4" 4' ( V w Fs=mm BL1A JUNCTION BOX FOR DATA (TASCO H �w o� kzomoao� PRINTERS • { �— p p ) VERTICAL RACEWAY) AT +52" AND 6" FROM v,gyo" Qozwawwoo __ { IG TWIST LOCK RECEPTACLE ROUTE CIRCUITRY BELOW OVERHEAD ROLLING CLOSURE SWITCH �o NzslLLamammar IG DUPLEX RECEPTACLE JUNCTION BOX FOR DATA 7"1'-6" 1'-1" 4'-6" 1'-6" 3'-7" 3'-3" 10" DOOR FRAME. COORDINATE LOCATION WITH (REGISTER) BOTTOM SHELF ON THE AP INSTALLER PRIOR TO ROUGH-IN. 19 TASCO ROUTE 2" CONDUIT UNDER SLAB P BL1A pi ( ) INTERIOR OF CABINET, TYP p � IG TWIST LOCK RECEPTACLE 6"x6"x4" JUNCTION BOX TO RESTROOM WALL, STUB OUT 8" ABOVE 16.619 PROVIDE RECESSED ALARM JUNCTION BOX VIII ! (REGISTER) LAY-IN CEILING AND TERMINATE WITH BUSHING IN CEILING WITH 4"x4"x1-1/2" EXTENSION Qh o I RING WITH RACEWAY ROUTED TO NEAREST 23 ACCESSIBLE CEILING SPACE. lu E CHASE WALL 1 BLiA PREWIRED CHECKOUT COUNTER PHARMACY INTERIOR ELEVATION " °9W t 16.622 PROVIDE RECESSED 4"x4 x1-1/2" ALARM Wz a N { C PHOTO LAB j CHASE W LL } 3/8" = 1'-O" 02.10.11 E-PP-42NCRR-PREWIRE 1/4" = 1'-0" 02.10.11 ERX15R JUNCTION BOX (WITH VERTICAL RACEWAY) 1 w`� xP I AT +52" WITH 4"x4"x1-1/2" EXTENSION to Zo w o a o 16.413 : j 21 RING AND 4"x4" TWO-GANG DEVICE RING. z wz ! BL1A 16.668 CONDUIT SLEEVE: PROVIDE 2" (UNLESS _� - 1 ! NOTED OTHERWISE) CONDUIT (WITH PULL WIRE) FROM PROVIDED DATA ENCLOSURE TO zo 12" ABOVE CEILING AND TERMINATE WITH BUSHINGS. U +26" AT ER O rJ.rJ O 16.673 CONDUIT SLEEVE: PROVIDE (2) 1 1/2" COUNTER ! , 1" C 116_228 �J CONDUITS (WITH PULL WIRE) FROM BAR I 16.452 `1 ST TOP PROVIDED DATA ENCLOSURE AND I 16.408 Y{i { JOI R N I ------ - -------------- ------- ---------------- -------------------------------------- ----- ----------- - - t � TERMINATE WITH BUSHINGS. ! 16 H - - B�1A _ - _— - v- { - - - _ _—_ - 16.675 CONDUIT SLEEVE: PROVIDE 2" CONDUIT Ll OUTLET BOX PRE-INSTALLED BY CABINET 72M 7 9 72M� is 15117 I2M s 1 1012 72M ? } 1618 77M t - - SLEEVE (WITH PULL WIRE) FROM PROVIDED �-� r 3-`` 44 0`� DATA ENCLOSllRE. UTILIZING A 2" ALUMINllM P MANUFACTURER. PROVIDE RECEPTACLE, cm TYPE LB CONDUIT BODY, STUB OUT TO 8" __ COVERPLAT_E, AND CIRCUITRY ! LlDl ^0 — 3 (PART 2/2) ABOVE ADJACENT SUSPENDED CEILING. _ 2 ROUTE ALL CIRCUITRY THROUGH COUNTERS i B 2 -8 ! - t TERMINATE WITH BUSHING. Jt 1-J� Lo 6G AND WALLS UNLESS NOTED OTHERWISE 1 1 3 ! ' 6 0D7 ! w n H 16.677 CONDUIT SLEEVE: PROVIDE 2" CONDUIT iL r� N I PD2 ISLANDER. t ` 1 I` w 1-- F BL1A J � FROM 12" ABOVE PHARMACY SUSPENDED u I-�a 6j = — --i ! } ` I ! { } I ! { { CEILING TO ABOVE BAR JOIST. ROUTE Q VERIFY EXACT PHOTO { i j i 1 ISLANDER LOCATION IAND I STUB 1/2 CONDUIT 12" 1 - ' 1 O I CONDUIT TO ABOVE 1 i I I , ! CONDUIT TO THE TOP SIDE OF CABLE TRAY I ABOVE LAY-IN CEILING AND { J CONFIGURATION WITH INAL CEILING TYP 1 j 1 t ! { { 1 TERMINATE WITH BUSHING i j ! 3 } I WITH THE CONDUIT CONNECTOR AND MERCHANDISE PLAN ik I i I { BUSHING EXTENDING NO MORE THAN 1" W ! I U, I { I OVER CABLE TRAY. INSTALL FURNISHED OWER ( M1 r� e� 1 POLE FROM- STRUCT�RE TO ❑i Dl i ! I I { 1 ( { ( 16.679 DATA AND PHONE CONDUITS: PROVIDE (3) w O o VOICE/DATA DUPLEX II g 1B DIGITAL ISLANDER FTER JUNCTION SOX RECEPTACLE ! J ! t 3" CONDUITS (WITH PULL WIRE) FROM O ci 30 MILLWORK I SET IN LACE. 0{ � 1 { { j ! ENCLOSURE UP TO BAR JOIST, TURN 90 FINAL EQUIPMENT { 0 ; 10'-1" + 10'-6" 5' 2' i 1 10'-9" 10'-101' 2'; " 7'-8' 1 I 9'-O" I DEGREES AND ROUTE TO THE TOP SIDE OF 1 1 CONNECTION TO POWER j fl I. 0 1 1 I { CABLE TRAY WITH THE CONDUIT CONNECTOR 1 POLE BY OTHERS, ;TYP D j I D� RACK POST 1 AND BUSHING EXTENDING NO MORE THAN 1 w } 0 I n TIP I 1 I OVER CABLE TRAY. TERMINATE WITH HP EQUIPMENT 06H �f, ! ! + , In _ — _— _ _ _ _ _— _ { _ —_ —} 1 _ _ - _ ! BUSHINGS. � r ! 1 SPECIFIC POWER 3 .i t i ? ! ao 71SHELF { I Z [ OLE. LOCATE ON { ;,`-% ( } I DtDi TYP `/ 19 1 i I P PRINT STATION GL1 B BL1 B I ! ` �— � {' ; ; I t°s BL1 B 21 ? i — ' o !DE OF !SLANDER 12 ; 0 01 6 I ! } j 5i J 1 C7 0 -- ! 1 1 1 �{ 7 J 7 J L.._._.1. IR p 1 t { • PD2 PD2 PD 1 { ISSUE BLOCK t i ! 13'-2" 13'-O" { { I TYP 006B� I 1 t iot 876 I { I E3 1 ! PHARMACY RACK POWER ! { I 11'-0" �✓g" I 1 E v NTS 06.30.D6 ERX12R I i t 1 t I{ i BL1 B BL1 B r� 72 J / J (PART. 1/2) I,� t5G 2 N' 7 9 4T 5BL1B ! BL13B iBJ 1 BO5Q IL J (j5G J�2G 6 NP PD1 J J 05G - 1 PD2 72G PD2 t E3 PD2 ! PD2 3 PHOTO LAB POWER PLAN Q-4/ LECTRONICS POWER PLAN CHECKED BY- DRAWN BY: TLC O 6.rJ O 7.5 FILE NAME: E2.3 PROTO CYCLE 012712 1 ! DOCUMENT DATE: 041012 ----_-_ - -- ---- -------------------------------------------------------------_---I------------------------------- - i t SEASONAL KIOSK III --- - - - - - - --- - - -------fYP'�3-----�--1 ------------------------------------------------------------ ------------- 1---- ! 1---- 1— 1 ! t ! ! { t 1 � t i IAM EdIl IAI- SENT AM ' N TL2D2 EQUIP €NT 6-416->f6" JUNCTIOI�T>BOX CLOSET FR VESTIBULE HEA N. 20 �D32 34D2{ 1 L2D2 Ot�ITROLLER, +60" 1 t 2 ! ! PRE-WIRED COUNTER MOUNTED DEVICES: t i t L2D21 EF CHECKOUT CIRCUITRY IS v STUB 15' OF FLEXIBLE METAL CO DUIT ! I { i i { I 16.228 L2U J6 { +20" 1 PRE-INSTALLED BY OUT OF WALL AT FLOOR LEVEL. AFTER 12 I t I CABINET MANUFACTURER. COUNTERS ARE SET, ROUTE FLEXIBLE L2D2 16.227 + t 16.668 g 22 } REF ARCHITECTURAL ! METAL CONDUITS UNDERNEA H ! i � ! i L2D2 L2D2 ABINET TERMINATION I (PART. 2/3) (PART 1/3) JUNCTION BOINETRY OX. CCONDUIT DROPS ARE I t 1 E (PART 1/2) t NOT ALLOWED AT FRONT COUNTERS, TYP GFI L2U 1 ��� °� 4 OA t-0u i STALL FUR (SHED 2 02 LRX -I o i I LRX 6 RECIRCULA77NG } I r� - roe t} _ 3 BUTTON C' NTROL I ( ! I-t !O j ! t0 ! MEN PUMP STATION FOR OVERHEAD 4 PART 2 3 10 ! " WOMEN t ; 16.677 ROLLING CLOSURE RX 2 ROUTE 1" CONDUIT FROM ATA { �F t ___ V_E_R_H_E_A_D_ R_0_ IN ___ ___________ __LPART 212�� gXI ! BOX IN COUNTER TO 12 BOVE { ti (q� `- E r I 6X16 \LRX OCLOSURE MOTOR LAY-IN CEILING, T P OF1 2TE I t { 11 6-E2.3 CHECKOUT LR WITH BUSHING, TYP OF 2 r`SIPROF !+ a F o EACH DA t BOX INSIDE 11 A P III --- -- -- -- P 2 _ 91 + �—Y�a. 16.619 i i 14 PHARMACY T ' EI A ! 1 _ ---- 9 -- --- - - (PARI S S 6 �N� L2I - € L_�- i r L D2 16 SEPARATE C (PAR 3 �- -- --- i ---- I -� • +54" +4 " ¢ 723 i DATA BOX TOt 12t" OVE LAY- L J °' 1° - +3 " } [ (`� !t =-- _-_=yt s CEILING UNLES D OTHE SE`_ 1 1 +43" I TERMINATE COAD T WITH BU { t 3 ! r ° c LRX ° LRX LRX A I4 i1 L I !r t 1 !I }I I ate 1 1 EF 16.622 — { ! ' RX 5 7 4-E2.3 1LRX 3 r------ �1„C LRX (PART. 2/2) PHARMACY 5-y2.3 s 2"C 16.675 a 1 c1 I ct 1 c1 { t : 116.619 16.228 t I L2U 15 + LRX r r�i t i ! ! r' A (PART. 1LITE COUN •RII 1 I I I -- 3 ! LRX 1 Ii 1 1 I� 1 1 IR�jCUITRY UND It ENLARGED ------- TOILET i { 13 1 II 1 1 11 I 1 ISLAB TO PAN L�! 1 1 1� 1 L2D2 2 t 1 1 1 11 1 1 11 1 1 11 1 LRX TIP 111 1 I I I ! 6" 111 -- ti ' ti 1 i i1 I III POWER ---- VOLTAG�NTQIRE OTE WITH PRRIGA710ULL N CONTROLLER J J 'FOR LOJ L-J a � PLANS 1” CONDUIT FOR IRRIGATION POWER TO REMOTE IRRIGATION CONTROLLER ! i CONDUIT STUB UPS W}TH 1 1 ! DIMENSIONS SHOWN ON ({ I I I ARCHITECTURAL PLANS TYP { t , YPHARCY FRONT RESTROOM POWER PLAN Q MA � Q SHEET: s E2 . 3 Q 0 KEYNOTES 3.4 O 16.220 INSTALL PREFABRICATED ELECTRICAL DISTRIBUTION CENTER (EDC). EQUIPMENT AND INTERNAL WIRING ARE SHOWN FOR INFORMATION PURPOSES ONLY. THE ENTIRE ASSEMBLY WILL ARRIVE COMPLETELY ' t PRE-WIRED AND IS AN ETL LISTED ------------------------------------- 1 ASSEMBLY. ! f� I ) 16.227 ELECTRIC WATER COOLER RECEPTACLE: ?' PRO'A[ E ON/OFF CONCEAL WITHIN CABINET PER SIT. LIGHTIN +72" SAFETY SWITCH FOR MANUFACTURERS REQUIREMENTS. } RAF 1-Ei.2` . UI ITT HEATER 48" +48" +48" 30A, +60" +48" 16.228 INSTALL RECEPTACLE IN PROVIDED DATA ENCLOSURE. COORDINATE LOCATION OF RECEPTACE WITH IS CABLE VENDOR. J - j p +12" - - c -_ c c 16.427 PROVIDE RECEPTACLE AND 3/4" CONDUIT v c LID, c FROM FURNISHED LEVELER PUSH BUTTON +60" UH 5 L1 D1 j- - ---- -( CONTROLLER TO RECEPTACLE IN DOCK WELL 16.610 9 -0" } { 13 O PER MANUFACTURER'S INSTALLA11ON w c n oo� 6" BELOW L1 DI ?. INSTRUCTIONS. S*f2_ <z we z< ....... .. .. ..... .....t.,. . _ j t...} ....p. .. ........... .... t 6 60 w of Z<«o�w 2WF I ti BAR JOIST I 1 3 PROVIDE RECESSED ALARM JUNCTION BOX :Z<10 ww ao$ (WITH VERTICAL RACEWAY) AT +80" WITH < >_ Lr,32 6" BELOW w u w ' BAR JOIST } << cloo arc�woow INSECT 1 { + j - j 4"x4%1-1/2" EXTENSION RING (UNLESS o ay a=N w � yam I Ic 90" L1 D1 I 1 ] ti 3w�w� ,000 CONTROL, + '6" It )• z <�zoow o0 16.650 ! �- NOTED OTHERWISE m Yrc�ooraLw�w� I- 1 ° 16.610 PROVIDE SURFACE MOUNTED ALARM IL -,,i,1Z'oa aozQ !!! } LPTV, +90" ? j � i { } A } 1 e JUNCTION BOX (WITH VERTICAL RACEWAY) ¢ <W<, �ao--z-.a } 1 ,t ! t �ti \ } HALLWAY J a<k<tzF,wiK4U�ONJ 9 1 �zzoSw www 3 L1 D1 INSECTS ;' 7 \ \ i 16.650 16.622 j j_ - { AT +84" (UNLESS NOTED OTHERWISE). a 00o Na z s-owo� CONTROL16.650 16.622 ; 16.613 ALARM BACKBOARD CONDUITS: PROVIDE �gy_ZogoQNa��Qo N +96" j f +44" i (2) 2" CONDUITS (WITH PULL WIRE) FROM a ' "' .......... ""' '"'" "" BACKBOARD TO TOP SIDE OF THE BOTTOM A s " A ""' +48 ° CHORD OF BAR JOIST, TURN HORIZONTAL = �} °. J 3 X48" -�j } AND ROUTE TO THE TOP SIDE OF CABLE �� t F11 TRAY WITH THE CONDUIT CONNECTOR AND a. N 48':. ! t Ij +84 Vf L-: BUSHING EXTENDING NO MORE THAN 1" Li RECEIVING 1 t i 48" OVER CABLE TRAY. PROVIDE (1) 2" cgs" t INVOICING III o e _« .. t n t CONDUIT (WITH PULL WIRE) TO TOP SIDE OF OZ s Lu a 16.650 �-� �- THE BOTTOM CHORD OF BAR JOIST, TURN o t AD , j� IE ` N zo i } B HORIZONTAL AND EXTEND OUT OVER z W Jho OFFICE - I PER NEL IQ, t} AISLEWAY. STUB CONDUITS 2" BELOW THE a = mW< a: iJ I ° 1 1, TOP OF BACKBOARD AT STENCILED CONDUIT t i n 4 ': ENTRY AREA AND TERMINATE WITH €I tr ( ! [; t 1 1 I ;; �t� - i BUSHINGS z 1 I } 16.615 PROVIDE SURFACE MOUNTED SINGLE GANG 0 !!! ; -7- c_ m4 SWITCH BOX (WITH VERTICAL RACEWAY) AT +48" - ! ���-I� I, ----HD2 1D2 +48" AND 6" FROM DOOR FRAME. + --- -------;- ------ J L ! }j I 1--� t 16.618 FIRE ALARM BACKBOARD: PROVIDE 120V CONNECTIONS TO FIRE ALARM BACKBOARD INSTALL FURNISHED .................. .............................. ..... ....... I ? _......... i IRE LEVELER CONTROL, 1 ALARM INSTAL R COORDINATE BUILDING F -_ _---- -= L1D2 I} L1 2 I- _ } Ll2 L1D2 i wo PROVISIONS WITHFIREALARM INSTALLER ER • +54", TYP OF 2 _jl_ L- -- -- 40"x40" �d 0 i t PRIOR TO ROUGH-IN. O � t j = PACEI FOR DPS - __J ~ 16.650 TRAINING 16.619 PROVIDE RECESSED ALARM JUNCTION BOX �-PROVIDE ON/OFF ! }� _ ! r UPS UPC IN CEILING WITH 4"x4"x1-1/2" EXTENSION O 1 j I ] I=mo ! RING WITH RACEWAY ROUTED TO NEAREST SAFETY SWITCH FOR fi t / L1 D1 I t 1 ACCESSIBLE CEILING SPACE. F DOCK LEVELER, ° + Ln } j +60", TYP OF 2 L1D2 w I II J - JI -34 i 16.622 PROVIDE RECESSED 4"x4"x1-1/2" ALARM �Ny WPi i } Ila,+84" ! t 1 M--�-9 r ,-- JUNCTION BOX WITH VERTICAL RACEWAY w i Ln AT +52" WITH 4"x4"x1-1 2" EXTENSION Q AZ ' t ' 5'-5" 26 L1U k RING AND 4"x4" TWO-GANG DEVICE RING. _ ! ! ; 16.427 1 ! +84" +-. L1 D / ;! _ �_ 16.650 CONDUIT SLEEVE: PROVIDE 1-1/2 CONDUIT LJ } �2 ;j L6-30R 1 ;i jj SLEEVE WITH BUSHINGS ABOVE BAR JOIST Q M ' ' CBL J I (UNLESS NOTED OTHERWISE). O c INSECT } rl Ir -i� (: (fl' � RC � __ t 16.652 DATA AND PHONE CONDUITS: PROVIDE (3) O CO - CONTROL, ! �lJ I INSTALLED AS DIM STONED �!t j II -- jj 3" CONDUITS (WITH PULL WIRE) TO CABLE 0 +96" °► f3 , ® o ( TRAY. ROUTE CONDUIT TO THE TOP SIDE OF 4 ! CABLE TRAY WITH THE CONDUIT CONNECTOR C� ------- - 1 11 °° I AND BUSHING EXTENDING NO MORE THAN 1 3 lDlj j } gj 3 „ ' != L1U OVER CABLE(TRAY. PROVIDE (1) 2RA " AND (1) it L 'o 3 L6-30R, '� i 3" CONDUIT WITH PULL WIRE TO TOP SIDE 7 � 16.652 ' OF THE BOTTOM CHORD OF BAR JOIST, q PANED ABEL "UPS" I • L1U jl t i TURN HORIZONTAL AND EXTEND OUT OVER tt :' 3 1 L1 D2._............ - 1 - _-- AISLEWAY. STUB CONDUITS 6" BELOW DROP - CEILING AND TERMINATE WITH BUSHINGS. WPQJ j i BEL "SW/1" G , ---- ___ _ __ _---_ 16.658 CONDUIT SLEEVE: PROVIDE 2" CONDUIT a - PROVIDED DATIAEENC ENCLOSURE} 16.427 WALKIE-STACKER, j FROM ISSUE BLOCK MOUNT TO FRONT WITH OF RA , 2 0", L1 Dl 11 9U 16.659 ONDUITSSEEVE: PROVIDE 2" (UNLESS TYP16.658 11 I NOTED OTHERWISE) CONDUIT (WITH PULL LlU WIRE) W CEILING TO L� } 16.228 13 I Al FI "SW,/2" LlD5 ABOVE BUSHINGS- L5-30R GFROM MING ANDOTERMINATE WITH " 11, , ,, L5-30R 8 L1U 16.663 ENERGY MANAGEMENT CONDUITS: PROVIDE LTJ 8 6 (2) 2" CONDUITS (WITH PULL WIRE) FROM EMS BACKBOARD TO TOP SIDE OF THE I BOTTOM CHORD OF BAR JOIST. TURN -- ----------- =- - ----- --------------- ---------- ------------------- HORIZONTAL AND ROUTE TO THE TOP SIDE OF CABLE TRAY WITH THE CONDUIT tea t ; T CONNECTOR AND BUSHING EXTENDING NO OFFICE POWER PLAN MORE THAN 1" OVER CABLE TRAY. STUB 3 RECEIVING P 0 W E R PLAN 2 ,,4" - ,'_D" CONDUITS 2" BELOW THE TOP OF BACKBOARD AND TERMINATE WITH BUSHINGS. 16.664 TELEPHONE BACKBOARD CONDUITS: PROVIDE (3) 3" CONDUITS (WITH PULL WIRE) FROM BACKBOARD TO TOP SIDE OF THE BOTTOM CHORD OF BAR JOIST, TURN HORIZONTAL AND ROUTE TO THE TOP SIDE OF CABLE CHECKED BY: TRAY WITH THE CONDUIT CONNECTOR AND BUSHING EXTENDING NO MORE THAN 1" DRAWN BY: TLC OVER CABLE TRAY. PROVIDE (1) 2" AND (1) FILE NAME: E2.4 3" CONDUIT (WITH PULL WIRE) TO TOP SIDE OF THE BOTTOM CHORD OF BAR JOIST, PROTO CYCLE: 012712 /�� TURN HORIZONTAL AND EXTEND OUT OVER 4.5 O 5.5 b ) 6.rJ AISLEWAY- STUB CONDUITS 2" BELOW THE DOCUMENT DATE: 041012 �� TOP OF BACKBOARD AT STENCILED CONDUIT ENTRY AREA AND TERMINATE WITH BUSHINGS. (2) 4" CONDUITS FOR E3 = ! TELEPHONE SERVICE 1" FOR REMOTE t TVSS/H STACKED TAMPER DEVICE H1P1 STACKED L1®1-2/L1D2 BRKR/ } -- --� t �I INSECT r-- --__--, INSECT TE LIGHTING - 1 REF 1 E1.2 + j CT PULL L1D3 BRKR/ it, CONTROL,It - ! ; 6 } 26 22 18 + } T,D STACKED if If -____--_--_--�- -_ , - -_-_-_ s_ A �6 _-_-_ a_-_ _ L- --_ -- __-_-__-_ &-_-__-----_-- ------�+ _--_ ®__- = ---------- ----- b ( +12" - -0 1 SPRINKLER 2 I j 1 2 3 t L7,11f { ! I ,3 - I18 L1D1 L/01 RISERS E3 L1 D1 19 26 22 18 ! SPRINKL�Rj MSB H1A L1D1-1 TELEPHONE EDC1 16.613 ELECTR C 24 20 16 J CHASE 16.220 = PALLET JACK, L1D1 L1 D1 1 L D1 ------ FACE INSTALL FURNISHED 16.618 i EMS BOARD 16.650 MOUNTED HINGED TELEPHONE BOARD ALARM BOARD t ! O } -------------}---- iFf 9 i ENCLOSURE, +60" , j { I I i 1 }_ ! L _J 0 ��p PR6FfS I a 71 \� f5��NGINEF9`rj0 { I i If v }p It I 72336PE j ! 48" FOR BIKE ASSEMBLY. VERIFY ! 16 RECIRCULATING 1 _r1 Irl_ 18 LOC TION WITH STORE PLANNING SET-UP _ t j 1 ;(�' 2141 tia o 0 SUPERVISOR PRIOR TO ROUGH-IN, TYP OF 4 PUMP --- -- - - ------ ---- B 'Lo 1 E ® I R Ari 1 �i j 3 E +43" j 16.227 ;: i u F O PP Lo LIDI A- 1 16619 1 4 51 16.603 ; } # +60", NO} 'j '+ L1 b1 A PIRES. {} EXTENSION' .I ' 34 j ? + , # d MEN _ ; ; ; �!- � ' 1 t ! c, +5 E L "! RING }` i 36 WH, +20" ; _..- _- .: r- t BREAK L1 D1 ! L1 D1 J f _ - 16.650 j L7 2 I I E h L �- 1 I ! " 4 t -� ROOM TELXON CHARGER, / 49 ° ! t i ' S5 - _ _ P t MOUNT TO RACK 1 45 FAMILY I . g +48" l: 27 + !! 6 GW + I ? L1 D2 L1 D1 }� TOILET . L1 D2 ALCOVE . _ 1� 1 _ 43 47 i r I fT ! } j } ! ~! A !! 35 1 : . . I_ GFT, +4f i I MOU T TO CLAIMS ' ALLWAY ( t' ; EF . 21 } 1 RACX, +48" 36 45 i I - +46" 8 INSECT MOVABLE RACK JUNCTION BOX AND L1 1 +48" JANITOR 47 a, +54 -� CORD SET (FURNISHED WITH UNITS). 53 s } ' _ �` ` 1210 ! ENLARGED I =- 516.619 j : CONTROL, +96" { 1 MOUNT AT +48 AND CONNECT TO b 33! A WOMEN _= a 21 31 (�- D2 L1D 2 I + : 47 E 1 ,' _ lil JUNCTION BOX AS SHOWN, TYP OF 4 L1D2 L1b2 } .; =I _� POWER 16.619 a9 i �:pj i 12 j 1 I NS +48t E b' +43" Ll 2 - ( i'j p r --------------------------- --- ----- - ----------- --- --- ------------------------ ----- ---- J - J - J - J --- -- J --- --- - - -- - -- ------- .._.._.. .- - - - -- ------ 1. _----- -- -- -- - PLA .._. s r I T VA13LT } - i - } 1 I 10 2" MOUNT TO FRONT OF1 2 GFT, +46" AND } ! . I RACK +48", TYP OF i E24 , r � f � +24" STACKED f Y STOCKROOM POWER PLAN SHEET: 0 1 - a E2 . a GENERAL NOTES ELECTRICAL SYMBOLS A B C A B C A B C INSTALLED BY 10.28.05 VOICE/DATA ROUGH-IN SCHEDULE ES02 10.29.10 LEGEND ES03 OTHERS ..................•••••• SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS o 6: c., DROP ROUGH-IN NOTES: 1. PROVIDE SEALS AT RACEWAY PENETRATIONS AS ( ) o f --y j--- FOLLOWS: EMS 1/0 SYMBOL DESCRIPTION LOW VOLTAGE i I A. FIRE RATED WALLS: SEAL PER CABLING TO DATA 5 - '-- ;i ___-� I i REF EM1 I Vc -a FLUSH MOUNT JUNCTION BOX AT +20" (UNO) WITH (1) 3/4" CONDUIT STUBBED 12" ABOVE LAY-IN CEILING. INCANDESCENT OR HID FIXTURE " SPECIFICATIONS FOR FIRE STOPPING. / Q LOGGER BY OTHERS r - s (WALL MOUNTED/CEILING MOUNTED) REF 11-E3� J CST's. ;CTs ICT CT' . CT CTI CST I •CT (CTI " '""' B. NEUTRALIZATION AREA: SEAL PER LTA � 1 J i 1 LT u POTTED Vb , Vb FLUSH MOUNT JUNCTION BOX AT +20" (UNO) WITH (1) 3/4" CONDUIT ROUTED TO NEAREST ACCESSIBLE CEILING SPACE. MECHANICAL DETAIL 0 FLUORESCENT FIXTURE R BK Y R BK Ys RI BK! Yk_ ASSEMBLY TYP SURFACE MOUNT JUNCTION BOX AT +66" (UNO) WITH (1) 3/4" CONDUIT STUBBED TO ACCESSIBLE CEILING SPACE_ C. FREEZER/COOLER BOXES: SEAL WITH Vc �c FLUORESCENT FIXTURE, j ? ' ! DATA EXPANDING FOAM SEALANT. VOLTAGE 1, { W _i W W LOGGER SURFACE MOUNT JUNCTION BOX AT +60" WITH (1) 3/4" CONDUIT STUBBED TO CONDUIT SLEEVE. D. EXTERIOR: REFER TO ARCHITECTURAL NIGHT LIGHT REFERENCE {; I { ! i 3'� 1 1j � Vd �d DOCUMENTS FOR SEALING REQUIREMENTS AT ❑ ENCLOSED FREEZER LIGHT BREAKER R BK Y R BK Y R BK Y NEUTRAL VOLTAGE SURFACE MOUNT WEATHER PROOF JUNCTION BOX AT TRUSS WITH 1 3 4" CONDUIT ROUTED TO SEASONAL SHOP ACCESSIBLE ALL EXTERIOR MOUNTED DEVICES, FIXTURES, � I LEAD IF APPLICABLE TYP BELDEN Q - O / ST� bl 1120A, TYP e e CEILING SPACE. ENCLOSURES, AND RACEWAY PENETRATIONS. E TRACK LIGHTING 8 c s @ 2. PROVIDE A SEPARATE EQUIPMENT GROUNDING TO MAIN EMS 4 ...•• KWH Vf Vf MOUNT JUNCTION BOX WITHIN ENCLOSURE WITH (1) 3/4" CONDUIT STUBBED TO ACCESSIBLE CEILING SPACE. EXIT FIXTURE C IN-LINE FUSE TYP TO NEXT CT, REF 1-E4 CONDUCTOR (SIZE PER NEC) IN PVC TYPE / CONTROLLER, REF EMS CT WALL MOUNTED CEILING MOUNTED 15/3 •-............•• FOR CT LOCATIONS, TYP CONDUIT, POWER CIRCUITS, ISOLATED GROUND ( / ) ONE-LINE DIAGRAM (�) Vg -g SURFACE MOUNT WEATHER PROOF JUNCTION BOX 6" BELOW CEILING WITH (1) 3/4" CONDUIT STUB TO ACCESSIBLE CEILING SPACE. CIRCUITS, OR AS SHOWN ON PLANS. CONDUIT } VOLTAGE REFERENCE WIRING DIAGRAM SHALL BE SIZED PER NEC BASED ON THWN EMERGENCY FIXTURE w c '^ < oder <z wp �z< 11 FLUSH MOUNT 2 1/8" DEEP JUNCTION BOX WITH DOUBLE GANG PLASTER RING AT +20" WITH (2) 3/4" CONDUITS STUBBED 12" 600 VOLT COPPER SINGLE CONDUCTORS, PLUS w wF�zaa�w�z o SUB - METERING Vh ' -h ABOVE LAY-IN CEILING. THE EQUIPMENT GROUNDING CONDUCTOR. SWITCH, SINGLE POLE W� a apJNwv aoo NTS 05.29.09 EP41 aa'Nowy 2�zlwnww LOW VOLTAGE WIRING V , -• SURFACE MOUNT JUNCTION BOX ADJACENT TO RACK CONTROLLER WITH (1) 3/4" CONDUIT STUBBED TO BUILDING ACCESSIBLE 3. WIRING DEVICES: DEVICE MOUNTING HEIGHTS o ��y�wk xD w ow 1 1 CEILING SPACE. COORDINATE RACK CONTROLLER JUNCTION BOX LOCATION WITH EMS INSTALLER. ARE FROM FINISHED FLOOR TO CENTER OF $3 SWITCH, 3-WAY a 'a 1 O NTS 10.28.11 EP40-1 SURFACE MOUNT WEATHER PROOF JUNCTION BOX AT +24" WITH (1) 3/4" CONDUIT ROUTED TO GARDEN CENTER (INSIDE SALES) OUTLET BOX UNLESS NOTED OTHERWISE ON zo 3�Q�LL'NwB�po€p Vk -k ACCESSIBLE CEILING SPACE. PLANS. COORDINATE THE STANDARD MOUNTING $¢ SWITCH, 4-WAY s- zwoa o�ou ,'LL Qa HEIGHTS WITH MASONRY: J a 2aFzw ao F p3 SCHEDULE GENERAL NOTES: �a k< Fw Foow< A. SWITCHES +46" azznsw wwwwo �w 1 ALL JUNCTION BOXES SHALL BE DOUBLE GANG WITH SINGLE GANG PLASTER RING UNLESS NOTED OTHERWISE ON SCHEDULE. B. RECEPTACLES +20" $K SWITCH, KEYED d ao��rl�i�� sz�No� C. VOICE/DATA (REFER TO SCHEDULE) =�gNzs��avwa�rcDDR (2) ALL JUNCTION BOXES TO BE ROUGHED IN AT SCHEDULED HEIGHT UNLESS NOTED OTHERWISE ON DRAWINGS. $D SWITCH, DIMMER (3) ALL CONDUITS SHALL BE TERMINATED WITH BUSHINGS. 4. WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT IN CONFORMANCE WITH SWITCH, VARIABLE SPEED =)m NO CONNECTION OF ANY KIND PROVIDE UNISTRUT PER (4) PROVIDE PULL WIRE WITH EACH EMPTY RACEWAY (JUNCTION BOX/CONDUIT) INSTALLED. EQUIPMENT SUPPLIER WIRING DIAGRAMS. Owl SHALL BE MADE TO JOIST WEB SPECIFICATIONS. LENGTH AS 5_ CONTRACTOR IS RESPONSIBLE FOR PROVIDING 09 o (5) CONDUIT RUNS SHALL HAVE NO MORE THAN 90 DEGREES OF TRANSITION BETWEEN PULL BOXES. M SWITCH, MANUAL MOTOR %A 09 MEMBERS OR JOIST BRIDGING BAR JOIST, REQUIRED TO SPAN JOISTS. COMPLETE PANELBOARD IDENTIFICATION $ �W m e TYP SECURE TO TOP CHORD OF (6) WHERE CONDUIT(S) TRAVERSE AREAS WITH CEILINGS OPEN TO STRUCTURE, CONDUIT(S) SHALL BE CONCEALED AS WELL AS POSSIBLE SCHEDULES. =N; m N BAR JOIST FROM VIEW FROM CUSTOMER AREA. S SWITCH, OCCUPANCY SENSOR W= a REF MANUFACTURER'S "GENERAL 6. BRANCH CIRCUIT CONDUCTORS SHALL BE �� N o FITTINGS SPECIFICATIONS" FOR r (7) FOR CONDUIT RUNS SCHEDULED WITH 1-1/2" OR LARGER CONDUIT UTILIZE LARGE RADIUS SWEEPS AT POINTS OF TRANSITION. MINIMUM #12 AWG UNLESS NOTED OTHERWISE us ZO wYo - R DESIGN BOLT TORQUE ` �,� UNISTRUT SHALL SUPPORT NO IN SCHEDULES_ WHERE 20A BRANCH CIRCUITS SWITCH, BI-LEVEL z g i 1 MORE THAT 100LBS IF P3300 IS (8) ACCESSIBLE CEILING SPACE SHALL BE CONSIDERED 12 INCHES ABOVE A LAY-IN CEILING OR ABOVE BAR JOIST ACCESSIBLE BY AS OCCUPANCY SENSOR ¢ W mW� r ^� USED AND NO MORE THAN NOTE: SCISSOR LIFT FOR AREAS OPEN TO STRUCTURE. HAVE #8 AND LARGER WIRE SPECIFIED, #10 F =W 215LBS IF P3000 IS USED 9 AWG WIRE SHALL BE USED FOR THE FINAL Q RECEPTACLE, DUPLEX � (i) GFI PROTECTION FOR CIRCUITS PROVIDED IN SYSTEM. O WHEN CABLE TRAY IS NOT PROVIDED, STUB CONDUIT(S) TO TOP SIDE OF BOTTOM CHORD OF JOISTS AND EXTEND TO ACCESSIBLE CONNECTION (15-FT MAXIMUM). U CEILING SPACE ON SALES FLOOR. z t tt II 7. WHERE BRANCH CIRCUITS ARE GROUPED, SIZE RECEPTACLE, DUPLEX, o 8'-0" CONDUIT AND DERATE CURRENT CARRYING MOUNTED HORIZONTALLY 1 CONDUCTORS PER NEC. a RECEPTACLE, DUPLEX FLUSH FLOOR PROVIDE LOCKING UNISTRUT li 8. PROVIDE HANDLE TIES ON ALL MULTIWIRE { BRANCH CIRCUITS TO MEET NEC REQUIREMENTS. RECEPTACLE, DUPLEX ISOLATED SPRING NUT PROVIDE ALL-THREAD r !` CONNECTION TO { LEFT SIDE OF PREP ( 9. CONDUITS EXTENDING BEYOND EXTERIOR WALL: a GROUND FLUSH FLOOR PROVIDE 1 4" ALL-THREAD, ��� AQUARIUM WALL STATION I / / ELECTRICAL EQUIPMENT / I �( STUB OUT 2'-0" BELOW GRADE TO 5'-O" !RECEPTACLE, DOUBLE DUPLEX O O p 1-1/4" FENDER WASHER, NEMA 4 24"x 24"x 8" BEYOND EXTERIOR WALLS UNLESS NOTED LOCK WASHER AND NUT, TYP t PROVIDE AIRCRAFT CABLE jT 11 ' ? I FLUSH MOUiJ sT<^v �% !- 1{1 PROVIDE SEPARATE SEAL PANEL OTHERWISE. COORDINATEE LOCATION AND A RECEPTACLE, DUPLEX %� �� SUSPENSION SYSTEM FOR J NEUTRAL FOR EACH FLANGE TO ENCLOSURE PROVIDE CONNECTION TO SITE CONDUITS. }{ ISOLATED GROUND AL1-THREAD SHALL BE INSET ;' CONNECTION TO f r_ j ! i i CIRCUIT a% EXTERIOR WALL HOFFMAN #CFM24248LG Q ELECTRICAL EQUIPMENT Ir 10. DATA AND PHONE CONDUIT INSTALLATION RECEPTACLE, DOUBLE DUPLEX, A SOLID PIECE. NO 1_ � I s MILESTONE DATE: ALL RACEWAY AND CONDUIT �..J SPLICES ALLOWED �` 7 �r co SLEEVES FOR DATA AND PHONE CABLING TO ISOLATED GROUND M o --- UNISTRUT �� � '� f' =' I Ii {± — — .-REFER TO DRAWINGS FOR ING E ST 3 WEEK RECEPTACLE, SIMPLEX TWIST LOCK, w E-' { l �- m i� I B INSTALLED S PRIOR TO CONTRACT K �y Cn O CIRCUIT IDENTIFICATION PADLOCK n COMPLETION n L5-15R, UNO is�� L[� a SUBSTANTIAL DATE. PROVIDE LOCKING < HANDLE I RECEPTACLE, SIMPLEX TWIST LOCK, SPRING NUT, TYP i;v = HOFFMAN 6" CHASE NIPPLE WITH 11. SUPPORTS FROM STRUCTURE: NO ATTACHMENT Q 1(101 O jl _ #CWHPTO ` LOCKNUT AND INSULATED OF ANY TYPE SHALL BE MADE TO BRIDGING OR ISOLATED GROUND, LS-]SR, UNO 1sv z P1 ! o r BUSHING TYP OF 4 JOIST WEB MEMBERS. UTILIZE ONLY THE TOP RECEPTACLE, DUPLEX TWIST LOCK, UNISTRUT CAN BE MOUNTED TO THE TOP ! t I{ —� s �` I OF EITHER THE TOP CHORD OR BOTTOM s { I AND BOTTOM CHORDS FOR SUPPORTING THE L5-15R, UNO Q V--! CHORD OF THE BAR JOIST I / ! ICONNECTIONSp .n L1 - UGHTING PREP ' Li 0 GENERAILAELECTR CAL OEF o RECEPTACLE, DUPLEX TWIST LOCK, I I I I ISOLATED GROUND, L5-15R, LINO I- o PROVIDE 1/4" HEX HEAD BOLT, P1 - HEATER/PUMP ___� STRUCTURE DETAIL. O r CONTRACTOR HAS THE OPTION TO USE 1-1/4" FENDER WASHER, AND INSET 1 12. DEVICES SHOWN ON COOLER/FREEZER PANELS RECEPTACLE, SPECIAL 0 EITHER METHOD OF INSTALLATION SHOWN LOCK WASHER, TYP FINISH TOP CHORD 1'-6" GRADE SHALL BE SURFACE MOUNTED UNLESS NOTED GENERAL ELECTRICAL OF BAR JOIST --3 OTHERWISE. REFER TO ARCHITECTURAL (P RECEPTACLE, SIMPLEX E­4 W I `' @ • v DOCUMENTS FOR CONDUIT INSTALLATION AND A U A R I U M WALL POWER I SEALING REQUIREMENTS. RECEPTACLE, PLUG-MOLD Z CONNECTIONS TO STRUCTURE CONCRETE 13. ONLY FEEDER CIRCUITS NOTED ON THE ONE Q NTS 09.26.08 EP06 FLOOR SLAB LINE DIAGRAM AND BRANCH CIRCUITS NOTED JUNCTION BOX pa v NTS 11.27.09 EL33 PORTABLE GENERATOR BY LEGEND SHALL BE INSTALLED UNDER SLAB. 0 (WALL MOUNTED/CEILING MOUNTED) ALL OTHER FEEDER AND BRANCH CIRCUITS ALARM JUNCTION BOX, ff 1f SHALL BE INSTALLED OVERHEAD. (WALL MOUNTED/CEILING MOUNTED) C CABLE RACEWAY 14. DO NOT INSTALL EQUIPMENT OR CONDUITS ALARM JUNCTION BOX, ISSUE BLOCK 7 NTS 05.29.09 EP32 DIRECTLY UNDER SKYLIGHT WELLS UNLESS ® FOR REMOTE TEST/RESET INDICATED OTHERWISE ON PLANS. (WALL MOUNTED/CEILING MOUNTED) 15. WHERE GROUPED CONDUITS ARE INSTALLED EQUIPMENT CONNECTION POINT WITHIN THE JOIST SPACE, COORDINATE WITH j (PROVIDED WITH EQUIPMENT) SPRINKLER CONTRACTOR PRIOR TO f e n J NO CONNECTION OF ANY KIND ' // INSTALLATION IN ORDER TO MAINTAIN REQUIRED Eh NON-FUSED DISCONNECT jjjfff r SHALL BE MADE TO JOIST WEB jjj �` $i CLEARANCES FROM SPRINKLERS € ' MEMBERS VR J010I PRIVVIIVV I lz Ia SI_rL COLUMN 16. SEI S,MIv `(INF PCQI IIPCAAENTC. PROVIDE ra r„nrrt DISCONNECT d CABLE TO SATELITTE + 7`( errs rwEv f <� �'• �� I� 1-1/4" WEATHERHEAD EXPANSION COUPLINGS AND BRACING FOR REF MANUFACTURER'S "GENERAL - f •. -.ham .r PROVIDED BY OTHERS _ I I POINT TOWARD SATELLITE MAST ELECTRICAL EQUIPMENT AS REQUIRED BY LOCAL "�"t" ouNo CIRCUIT, CONCEALED IN WALLS OR %_' FITTINGS SPECIFICATIONS" FOR j " F I 3'-0" CODES. Ho' S CEILING, E INDICATES EXISTING s DESIGN BOLT TORQUE EMS CABLE ROOF MEMBRANE , I PROVIDED BY OTHERS "I7o\ WIRING / £< / PROVIDE 1-1/4" CIRCUIT, CONCEALED IN SLAB FLOOR f f /fit r` f SEAL SYSTEM I, FENDER WASHER, ti E INDICATES EXISTING WIRING LOCK WASHER AND ' �` o I 3 EXTEND POWER POLE 3" _ j j I r o NUT, TYP CIRCUIT, EXPOSED, MIN ABOVE CL OF UNISTRUT INSULATION n E INDICATES EXISTING WIRING I I II � ,I I +I Y F-I CONDUIT SLEEVE y ; 12" PVC SLEEVE r j 11 11 I ! s { - PROVIDE 2"x2"x3/16" t p ' ANGLE IRON, TYP + ttt , t /s r, ; i I�` �� s �I � � u U ,{ 1� FLUSH MOUNTED PANELBOARD i 1 jI1{ / INSET ' � PROVIDE 1/4" BOLT '�____.,/ f 7 f , AND 1-1/4" FENDER SURFACE MOUNTED PANELBOARD PROVIDE UNISTRUT PER WASHER, TYP CHECKED BY: ' 'tel IiL1 SPECIFICATIONS. LENGTH AS i 1 T s e REQUIRED TO SPAN JOISTS. t� i DRAWN BY: TLC f--------- MANUFACTURED WIRING SYSTEM _ SECURE TO BOTTOM CHORD !ice I (1) 1-1/4" GRID ATTACH 2-1/2" UNISTRUT �' OF BAR JOIST. / �i 3 TO STEEL JOIST GIRDER IN TELEPHONE / DATA BOX FOR ISD FILE NAME: E3 STRAP FIRMLY CLAMPED j' CONTRACTOR SHALL ATTACH POWER � ? "� fes` 1 � � I `: TWO PLACES - TO CONDUIT POLE PER MANUFACTURER l� ' LOW VOLTAGE CABLE PROTO CYCLE 012712 RECOMMENDATIONS 4 PROVIDE 3/8"x2-1/8" V BOX FOR OTHER PROVIDE 1/4" BOLT s U-BOLTS WITH NUTS, LOCK DOCUMENT DATE 041012 AND 1-1/4" FENDER r WASHERS, AND ANGLE IRON � TELEPHONE, FLUSH FLOOR j UNISTRUT WASHER TYP BACK PLATES, TYP It/ I { MOTOR II ' ROVIDE UNISTRUT t P1026 ANGLE NO CONNECTION OF ANY KIND O TELEPOWER POLE ` POWER POLE FITTING OR EQUAL SHALL BE MADE TO JOIST WEB i- r MEMBERS OR JOIST BRIDGING PROVIDE BUSHING 2-1/2 INSET f [� _ PUSH BUTTON PVC CONDUIT , f SATELLITE DISH i 6 BUZZER INSET: CLAMP A 12" LENGTH I It PROVIDE 1-1/4" BOTTOM AND SENSOR MAST INSET SS SAIL SWITCH OF PVC CONDUIT AND RUN THE i ❑ JUNCTION BOX POWER POLE THROUGH ITS CENTER FENDER WASHER, LOCK INSET CHORD OF FINISHED WASHER AND NUT, TYP NTS 11.27.09 EP03 FLOOR BAR JOIST INSET: MOUNT UNISTRUT ABOVE BOTTOM CHORD OF BARJOISTS USING I 2 SMOKE DETECTOR POWERPOLE CONNECTION LOCK WASHERS/ETWEENSBOLT HEAD DAND JOSTER RFLAN6E CONDUIT TO I HORN / STROBE 6 NTS 02.26.10 EP42 OTHER JUNCTION PROVIDE 4 11/16"x BOXES � ® DOOR HOLD OPEN PROVIDE 1/2" CONDUIT, CAULK 2 1/8" BOX AND MAKE WATERTIGHT _ TO NEAREST 120V CIRCUIT 1 ---- --------- PROVIDE WEATHERPROOF ABBREVIATIONS BACKBOX FOR BELL AS PROVIDE 50 VA, 120/12/24 VOLT, CONDUITS SHALL STUB UP REQUIRED 1� TRANSFORMER IN NEMA 1 ABOVE TOP OF BOTTOM CF CEILING FAN QEDPR0? TO UPS PANELBCARC Y� ENCLOSURE. TRANSFORMER TO I CHORD OF JOIST ( \���N F,9`s0 GINE / 24 VOLT SPRINKLER SYSTEM ELECTRIC BELL { HAVE PRIMARY T AND SECONDARY 1 d� � �9 FROM PANELBOARD / ( ) 11 FT� CO CHECK GUT 7P336PE FEEDING UPS SYSTEM 1-1 4" FLEXIBLE BY SPRINKLER CONTRACTOR FUSE BLOCKS. PROVIDE ( / Q < METAL CONDUIT, TYP TRANSFORMER, ENCLOSURE, AND � � ( CW CASH WRAP WATER FLOW SWITCH (BY FINAL CONNECTIONS { Z ory EF EXHAUST FAN SPRINKLER CONTRACTOR) PROVIDE 3/4" CONDUIT G GROUND �LEGON'� CONTRACTOR MILESTONE: ALL TO 12"x12" ENCLOSURE WORK SHALL BE COMPLETED FOR PROVIDE 1/2" LIQUID CONDUIT AND BOX GFl GROUND FAULT CIRCUIT INTERRUPTER INSTALL MAINTENANCE UPS SYSTEM INSTALLATION 2 TIGHT CONDUIT (( �� EXPOSED ON COLUMN IG ISOLATED GROUND y„ (v/f Y FLEXIBLE METAL CONDUIT BYPASS CABINET ON WEEKS PRIOR TO POSSESSION 1 I PROVIDE 1/2” FLEXIBLE mRE_q Tr>1 3 PROVIDE TIE WIRES FOR ' WALL. UNIT FURNISHED DATE. THIS APPLIES TO SUPERVISORY (TAMPER) I CONDUIT FOR 24 VOLT REC REFRIGERATION ELECTRICAL CONTRACTOR BOX HANGER - THIS IS BY OTHERS BRANCH CIRCUIT WIRING FROM SWITCH (BY SPRINKLER WIRING RC REFRIGERATION CONTRACTOR NOT PART OF THE CEILING PROVIDE (3) #6 IN 1-1/4" C. ? I _ 11 ADJUSTABLE T-BAR BOX UPS PANELBOARDS TO LOADS CONTRACTOR) SWITCH PROVIDE 1 2" ' SUSPENSION TYP REF MANUFACTURER'S / RH RADIANT HEATER HANGER F SPAN 24" INSTALLATION INSTRUCTIONS SERVED THROUGHOUT THE STORE SHALL BE LOCATED IN { j FLEXIBLE CONDUIT I LENGTH OF CEILING TILE SUPPORT CLIP TO TIE FOR TERMINATIONS THE 12 O'CLOCK C SC SECURITY CAMERA (BOX SUPPORT PER NEC) WIRE AT MAXIMUM 4'-6" POSITION SPACING. ROUTE CONDUIT I I PROVIDE ALARM JUNCTION JUNCTION BOX AND ALARM JUNCTION BOX UH UNIT HEATER TO JUNCTION BOX AT PROVIDE 1 1/4" PIPE SLEEVE. BOX FOR EACH VALVE CONDUIT FOR SMOKE AND CONDUIT FOR JUNCTION BOX I DETECTOR TEST-RESET RlU SMOKE DETECTOR WH WATER HEATER FLUSH MOUNTED BAR JOIST CAULK AND MAKE WATER TIGHT AND STUB-OUT SWITCH AS SHOWN POPIT DEVICE AS WP WEATHER PROOF COVERPLATE ELECTRICAL IN LAY-IN CEILING I ON DRAWINGS SHOWN ON DRAWINGS INSTALL UPS SYSTEM. PROVIDE 4 11/16"x2 1/8" BOX I SPRINKLER RISER WR WEATHER RESISTANT RECEPTACLE DETAILS T-BAR PROVIDE (4) #6 IN 1-1/4" C. UNIT FURNISHED BY 1 y _ REF MANUFACTURER'S OTHERS UPS OUTPUT NEUTRAL INSTALLATION INSTRUCTIONS IS BONDED TO EARTH PROVIDE EMPTY CONDUIT(S) SYMBOLS, FOR TERMINATIONS GROUND INSIDE UPS WITH PULL STRING FOR REMOTE COLUMN +74 INCHES __ __ SYSTEM DEVICES AS REQUIRED. -- AND CEILING COORDINATE WITH CIVILS COVERPLATE PROVIDE GROUNDING NOTE: CONCEAL CONDUIT RECEPTACLE MOUNTED SCHEDULES FINISHEDzo ELECTRODE CONDUCTOR. AND USE FLUSH BOX ON RECEPTACLE FLOOR �r� ON COLUMN FACING REAR BONS TO BUILDING STEEL WRAPPED COLUMN SPRINKLER SYSTEM TAMPER OF STORE AS SHOWN ON DRAWINGS Y CEILING MOUNTED RECEPTACLE 3 USPS SYSTEM CONNECTION AND FLOW SWITCH CONNECTION COLUMN DEVICE MOUNTING SHEET: LI. C3 NTS 04.26.02 EP23 � NTS 10.28.11 EF11-1 1 NTS 04.26.02 EP25 E3 o.. 0 CT'S FURNISHED BY UTILITY, INSTALLED BY CONTRACTOR CT SIZING PANELBOARD NOTES O SWITCHBOARD NOTES RECEIVED CT'S LOCATED AT CT SWBDAPR O8 n � METER BASE FURNISHED BY CONTRACTOR, INSTALLED BY CONTRACTOR METER FURNISHED BY UTILITY, INSTALLED BY UTILITY INCOMING EDC VENDOR SHALL PROVIDE CTS WITH (1) TERMINATE GROUND ON ISOLATED GROUND BUS. 1. THE SWITCHBOARD IS PART OF A UL LISTED PRIMARY SERIES RATED SYSTEM THAT REQUIRES THE CiTY� tIG� METER LOCATION OUTSIDE ON EXTERIOR REAR WALL BEHIND MS81 EXTERIOR (1) #3/0 BARE COPPER AMPERAGE RATING PER FEEDER LOAD (2) INSTALL LOCKING DEVICE FURNISHED WITH DOWN STREAM BREAKERS TO BE TESTED WITH METERING SEQUENCE HOT SEQUENCING (CT'S ON LINE SIDE OF MAIN) WALL UTILITY __ LISTED IN PANELBOARD SCHEDULE AND PANELBOARD (LOCK-OFF FOR MAINTENANCE). THE SWITCHBOARD AS A COMPLETE UL LISTED gU)LDiNGDIVLSION TRANSFORMER -F ; RANGES IN THE FOLLOWING CHART: (3} INSTALL LOCKING DEVICE FURNISHED WITH SYSTEM. THE MANUFACTURER WILL PROVIDE e VERTICAL TELEPHONE EQUIPMENT BARE COPPER O PANELBOARD (LOCK-ON FOR CRITICAL LOAD). SPECIFIC BREAKER TYPES (CATALOG NUMBERS) °,2 1 g fa e EUSERC 345 CT SWITCHBOARD OUTSIDE WALL STEEL BUILDING FEEDER AMPS CT SIZE (4) GFI BREAKER FOR PERSONNEL PROTECTION TO COMPLY WITH THE TESTS FOR A SERIES 0 - 125 100 (5 EDA). RATED SYSTEM. ANY REPLACEMENT BREAKERS WITH TEST BLOCK PROVISIONS ' MAIN SUPPLIED SHALL MATCH EXISTING TYPES PROVIDED BY EDC VENDOR AS �� SWITCHBOARD NEUTRAL BUS -- 126 - 375 300 (5) GFI BREAKER FOR EQUIPMENT PROTECTION (CATALOG NUMBERS) SUPPLIED BY THE SECONDARY TERMINATIONS SPECIFIED AND APPROVED BY CONTRACTOR TO PROVIDE (8) 5" (30 mA). ORIGINAL SYSTEM MANUFACTURER. FAILURE TO AT TRANSFORMER BY UTILITY MAIN BONDING JUMPER SCHED. 40 PVC CONDUITS WITH 376 - 500 400 (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR SUPPLY THE CORRECT BREAKERS WILL VOID UTILITY COMPANY INCOMING TERMINATIONS F - BOND TO BUILDING PULL WIRE. UTILITY TO PROVIDE VOLTAGE DROP. SIZE EQUIPMENT GROUNDING THE SERIES SYSTEM RATING OF THE COMPLETE AT TRANSFORMER BY STEEL WITH EXOTHERMIC EQUIPMENT BONDING JUMPER AND INSTALL CONDUCTORS. 501 - 1000 800 CONDUCTOR PROPORTIONALLY PER NEC. ELECTRICAL SYSTEM. SERVICE TRANSFORMER UTILITY COMPANY WELD (7) REFER TO ONE-LINE DIAGRAM FOR AVAILABLE 2. PROVIDE GROUND FAULT TESTING OF THE REF CIVIL PLANS EQUIPMENT GROUND BUS 1001 - 2000 1600 FAULT CURRENT FOR INTERRUPTING RATINGS. SERVICE DISCONNECTS TO COMPLY WITH NEC. OUTGOING TERMINATIONS EUSERC 345 RATED CHECK FACTORY SETTINGS AND ADJUST AS AT CT SWBD BY CONTRACTOR 2001 - 3000 2400 (8) REFER TO ONE-LINE DIAGRAM FOR WIRE SIZES. PRIMARY TERMINATIONS rIMUST FINISHED FLOOR CT SWITCHBOARD REQUIRED TO OBTAIN THE FOLLOWING SETTINGS. W " < LL0< REF CIVIL PLANS CT FINISHED (9) FACTORY WIRED TO LOAD. THE GROUND FAULT RELAYS CURRENT 5 ow��� t izowoGRADE SENSITIVITY SHALL BE SET AT 40% OF THE W orFzaarcw�TRANSFORMER PAD SWBD ` i MSB I KWH CT (10) REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. MAIN SWITCH AMPERE RATING, BUT NOT TOREF CIVIL PLANS TERMINATIONS // '�� ` / '� (11) THRU CONTACTOR. EXCEED 1200A MAXIMUM SETTING. THE TIME poNfDELAY SHALL BE SET TO THE MAXIMUM. PRIOR Z: a9fo�� °wwow2AT MSB BY CONTRACTOR �� \\ \�1GROUNDING ELECTRODE CONDUCTOR (X} DESIGNATES "SMART" BREAKER. TO FINAL INSPECTION, PROVIDE A WRITTEN z a�zoowoolow °�SHALL EXIT FOUNDATION AT EDC COPY OF PERFORMANCE TEST TO THE Sao ow0��o�azOOZ a0wo <GROUND CHASE Q w�zmo waozFzyMa ¢ zAUTHORITY HAVING JURISDICTION. J a< arz F 4¢y �ow< �zzo�w wwV#3/0 BARE COPPER CONDUCTOR FROM 3. PORTABLE GENERATOR QUICK CONNECT a oo8 wwo F55!wm - Nrw No 4H o:owowoGROUNDING ELECTRODENEUTRAL BUS. EXTEND 20'-0" AT BREAKER: BREAKER "QC" IS LOAD-LIMITED m ���yoaw<rca'o PRIMARY SERVCE TRENCH, BACKFILL, SYSTEM INSTALLATIONBOTTOM OF FOUNDATION WITH MINIMUM SUB-METERING CT FURNISHED BY EDC MANUFACTURER. CT'S THROUGH THE ENERGY MANAGEMENT SYSTEMREF CIVIL PLANS CONDUITS AND CONDUCTORS SHALL BE IN STRICT **OF 2" COVERAGE MARKED WITH ARE FACTORY INSTALLED BY EDC MANUFACTURER. TO SELECTED STANDBY LOADS. BREAKER "QC" PROVIDED BY CONTRACTOR COMPLIANCE WITH LOCAL ALL OTHER CT'S INSTALLED BY ELECTRICAL CONTRACTOR AND (8) SETS OF (4) 500kcmil COPPER IS PROPERLY INTERLOCKED WITH THE MAIN Z3NI TRENCH, BACKFILL, CODES AND/OR AUTHORITYIF WATER SERVICE LINE IS METAL, IT VERIFIED FOR PROPER INSTALLATION BY SUB-METER CONTRACTOR. EACH IN 4" CONDUIT OR SERVICE ENTRANCE BREAKER TO PREVENT HUTILITY COMPANY: PORTLAND GENERAL ELEC. CONDUCTORS CONDUITS AND PULL WIRE HAVING JURISDICTION BE BONDED TO GROUNDING CH-# INDICATES CHANNELS USED FOR EACH CT'S ADDRESS SIMULTANEOUS OPERATION FROM TWO POWER O (8) SETS OF (4) 750kcmil ALUMINUM o CONTACT: RALPH REISBACK PROVIDED BY UTILITY PROVIDED BY CONTRACTOR SOURCES. V!a° W ^ E ELECTRODE SYSTEM WITH A #3/0 SELECTION SWITCH. REFER TO MANUFACTURER'S INSTALLATION EACH IN 4" CONDUIT ADDRESS: 9480 SW BECKMAN RD THWN COPPER CONDUCTOR. INSTRUCTIONS FOR POSITIONING SELECTION SWITCHES. VOLTAGE 4. EDC VENDOR SHALL PROVIDE A LABEL ON THE �'W w: CITY, STATE, ZIP: WILSONVILLE, OR 97070 REFERENCE WIRING BY ELECTRICAL CONTRACTOR, REF 11-E3. LOW FACE OF EACH SWITCHBOARD AND/OR W�. m PHONE: 503-570-4409 VOLTAGE WIRING BETWEEN DATA LOGGER EMS 1/O KWH AND CT'S PANELBOARD NEAR THE LOCATION OF EACH �� WY ° FAX: 503-570-4420 COORDINATE ALL REQUIREMENTS m Ze wao 0 WITH LOCAL ELECTRICAL UTILITY OUNDING EL E SYSTEM PROVIDED BY SUB-METER CONTRACTOR, REF 10-E3 __ BREAKER NUMBER, OADSUB-METERING CT. LSSHALL INDICATE ERVED AND CT a MZ 2i; ry r m (OR PRIMARY SERVICE PROVIDER NTS 04.26.02 EP07-1 - - -- ------- - - ------ --- ---- - -- - --- - - --- -- _{U UTILITY LI TY C00RDI N ATI0N WHERE PROVIDE PRIOR TO CHANNEL NUMBER. J m - MAIN SERVICE (MSB) - 3000 AMP BUS - BID. PROVIDE ALL MATERIAL AND <52,145 LABOR NECESSARY TO COMPLY 480/277 VOLT, 3 PHASE, 4 WIREI o NTS 07-27.01 EP26 WITH LOCAL REQUIREMENTS. CH-13 I 1 CH-18 SHUNT TRIP SHUNT TRIP I CH-19 e I A�1 I 1 CH-20 ST G ST GF 0 0 Z AHU1 CH-25 L-O 160OA-3P MAIN L-0 3000A-3P MAIN AHU2 KIRK KEY CH-26 0 O "QC" BREAKER BREAKER AHU31 INTERLOCK, MSB MSB * '� w I� o Lo SECTION 3 480/277V, 3PH, 4W 480/277V, 3PH, 4W r-------- -------- CH-12 Ln P4 SERVES: 480V DISTRIBUTION 3000A, M.L.O. SERVES: MAIN SERVICE 3000A, M.C.B. r------- CH-7 0 LOCATION: EDC1 (7) AIC, FULLY RATED LOCATION: EDC1 (7) AIC, FULLY RATED 0 O PANEL PROVIDED WITH EDC GROUND BUS PANEL PROVIDED WITH EDC GROUND BUS i j r----- CH-8 * SECTION 3 I SECTION 2 SECTION 1 z PANEL SHALL HAVE FULL LENGTH BUS FLOOR MOUNT FLOOR MOUNTLLI BREAKER DESCRIPTION WIRE BRKR PL VOLT-AMP TOTAL TOTAL SECTION DESCRIPTION VOLT-AMP TOTAL TOTAL i I PLM UNDERGROUND CONDUIT STUB-UPS: �Q c� PER PHASE KVA AMPS PER PHASE KVA AMPS i i COORDINATE LOCATION OF THE SERVICE Iwt O o AHU1 #4 90 3 A 20,036 3000A MAIN BREAKER i i I ---------------------------1 ENTRANCE CONDUITS, TELEPHONE SERVICE 1 480/3 B 20,036 60 72 1 CONDUIT(S) AND UNDERGROUND FEEDERS L___-_-_____ .--I C 20,036 1 i 1 i 1 I WITH EDC VENDOR SHOP DRAWINGS. 0 t� AHU2 #4 90 3 A 20,036 1600A GENERATOR BREAKERA17 150,30 B8 1 46,186 B6 43,539 E-I w 2 480/3 B 20,036 60 72 2 I I i REPRESENTS THE AVAILABLE FAULT pq C 20,036O CURRENT IN RMS SYMMETRICAL AHU3 #4 90 3 A 20,036 DISTRIBUTION SECTION Al675,951 PANEL PANEL PANEL I AMPERES AT THE RESPECTIVE Z 3 480/3 B 20,036 60 72 3 480/277/3 Ell 678,827 2,026 2,436 H1A H1P1 H1P2 i TRANSFORMER, PANEL, OR EQUIPMENT W 1 20,036 C 670,857 BASED ON INFORMATION RECEIVED FROM C o HYBRID HOUSE LTA (8) 0 3 A 82,307 A 675,951 THE UTILITY 4 480/3 B 82,307 247 297 TOTALS B 678,827 2,026 2,436 A14 149,534 LOW TEMP REFRIGERATION C 82,307 C 670,857 i NOTE: DASHED LINE ISSUE BLOCK HYBRID HOUSE MTB (8) 300 3 A 61,522 #1/0 CU T1D TRANSFORMER SHALL INDICATES FACTORY 5 480/3 B 61,522 185 222 PER NEC ARTICLE 220 TOTAL FEEDER LOAD 1,955 2,351 GND u1� 480V HAVE CLASS 155 PROVIDED WIRING TYP 03/14/13 REV_ #2 MEDIUM TEMP REFRIGERATION C 61,522 225 KVA INSULATION OR HIGHER HYBRID HOUSE MTC (8) 350 3 A 73,162 LOAD CONNECTED LOAD VA DIVERSITY DIVERSIFIED LOAD VA PROVIDE EXOTHERMIC Ir208Y/120V I \,. 6 480/3 B 73,162 219 264 LIGHTS 153,883 125`0 192,354 WELD TO NEAREST \ `__________________________________________________________� MEDIUM TEMP REFRIGERATION C 73,162 GENERAL RECEPTACLES 68,585 57% 39,293 AVAILABLE BUILDING - `---__-____� STEEL PER NEC, TYP )110 PANEL H1P1 (9) (8) 125 3 A 16,948 SPECIAL PURPOSE 187,341 100% 187,3417 480/277/3 B 19518 55 66 HVAC HEATING+ 135,ssa D% 11,347C 18,697 HVAC COOLING+ 664,526 100% 664,526 1PANEL H1P2 (9) (8) 100 3 A 16,837 REFRIG COMPRESSORS 650,974 100% 650,974 (2) SETS OF (4) #1/0 (4) 250kcmil AND 8 480/277/3 B 14,304 45 54 MOTORS 63,307 100% 63,307 AND (2) #2 GND/IG (2) #2 GND/IG COPPER Cl13,984 KITCHEN APPLIANCES 237,019 65% 154,062 COPPER EACH IN 2" C. PANEL L1 D1 1 225A-3P IN 2-1/2" C. 125A-3P (4) #1 AND (1) #6 GND PANEL H1A (9) (8) 400 3 A 93,614 LARGEST MOTOR 11,640 25% 2,910 OR 2-SECT. BRKR OR I CROPPER IN 1-1/2" C. 9 480/3 B 93,614 281 338 DIVERSIFIED VA: 1,954,766 (2) SETS OF (4) #3/0 (4) 350kcmil AND Cl93,614 DIVERSIFIED AMPS: 2357 AND (2) #1/0 GND/IG (2) #1/0 GND/IG ALUMINUM 1 (4) #2/0 AND (1) #4 GND PANEL H2B (8) 600 3 A 134,798 + DIVERSIFIED VA DOES NOT INCLUDE NON-COINCIDENT HEATING/COOLING LOAD ALUMINUM EACH IN 2" C. ___� IN 2-1/2" C. I ALUMINUM IN 2" C. 10 480/277/3 B 139,296 407 490 EDC1 5,358 1,787 C 133,196 ------ -- - -- - - ----- - - - - --- - - --- ---- - -- -- - - - - - - - -- PANEL H2A (8) 400 3 A 67,786 REF 3-E3 REF 3-E3 11 480/3 B 67,786 203 245 (UPS/UPC ROOM) UPS 8 KVA 8 KVA UPS (UPS/UPC ROOM) C 67,786 TRANSFORMER T1D (9) (8) 300 3 A 58,152 #8 CU #8 CU CHECKED BY: 12 225 KVA, 480/3 B 55,969 171 205 GND - = GND DRAWN BY: TLC C 56,436 PANEL PANEL EANBALER #10 30 3 A 3,880 L1D2 L1U FILE NAME: E4 3 10 HP, 480/3 B 3,880 12 14 NOTE: FEEDER CONDUITS THAT ARE NOTED ASU G 17,29$ A17 14,343 A14 17,830 A15 PROTO CYCLE: 012712 C 3,880 SHALL BE INSTALLED UNDER THE FLOOR SLAB. / (CBL ROOM) (UPS/UPC PARENTHESIS INDICA (BAKERY COMPACTOR #10 30 3 A 3,880 UNDERGROUND CONDUIT SIZE IS BASED ON ROOM) LOCATION TYP UTILITY) DOCUMENT DATE: 041012 14 10 HP, 480/3 B 3,880 12 14 SCHEDULE 40 PVC. REF SPECIFICATIONS C 3,880 MAIN MAIN MAIN A 675,951 PANEL PANEL PANEL TOTALS B 678,827 2,026 2,436 C 670,857 (HYBRID (HYBRID (HYBRID HOUSE LTA) HOUSE MTB) HOUSE MTC) PER NEC ARTICLE 220 TOTAL FEEDER LOAD 1,955 2,351 _-_ _- - _ _ _ - - - _ _ - _ _ - -- -_ -_ A17 14,755 Mr (2"C U/G) (3 Portland General Electric Company I PANEL PANEL I 11/19/12 / PGE 07.30.04 ELECTRICAL ONE- LINE FEEDER SCHEDULE ESO4-1 H2A L2U ` / FEEDER CONDUCTOR SIZE (75•C) CONDUIT SIZE (EMT) CONTACT: Enc Jeter-Pacland Eng. I I I I PHONE: (503)659-9500 COPPER ALUMINUM 3 PHASE CONDUCTORS, r- CH-9 **-----------------------J i L-------------------------------------- CUSTOMER NAME: Walmart Stores Inc. CONDUCTORS CONDUCTORS 3 PHASE CONDUCTORS 3 PHASE CONDUCTORS, I I I FEEDER �F (THWN) (XHHW-2} AND GROUND NEUTRAL, AND GROUND NEUTRAL,ISOLATED GROUND AND i f iOVEHI IADDRESS: 7800 SW Dartmouth Street,Tig�/ard, r., 223 AMPACITY I * A15 19,93 TRANSFORMER SHALL * SDPM/ENGR:7R�aipOh N. Reisbeck, SDPM72 WR: 678995 SETS PHASE & GROUND PHASE & GROUND COPPER ALUMINUM COPPER ALUMINUM COPPER ALUMINUM i (HAVE CLASS 155 NEUTRAL & I.G. NEUTRAL & I.G_ NO. FEEDERS FEEDERS NO. FEEDERS FEEDERS NO. FEEDERS FEEDERS 1 7 T2D INSULATION OR HIGHER wl �� FS PHONE: (503) 570-4409 �� � ODN 30 1 10 10 - - Al 1/2" - 61 1/2" - Cl 3/4" - 18,824 I B6 48OV 480V 50 1 8 10 6 6 A2 3/4" 3/4" 62 3/4" 1" C2 3/4" 1" i #2/0 CU i 225 KVA #2 Cu 75 KVA 3-PHASE SECONDARY LINE-LINE FAULT CURRENT (RMS) GND i 208Y/120V GND i208Y/120V 60 1 6 10 4 6 A3 3/4" 1" 63 1" 1" C3 1" 1-1/4" = I * = I PAD MOUNT? YES PANEL I (3) SETS OF (4) 300kcmil I TRANSFORMER DATA 65 1 6 8 4 6 A4 3/4" 1" B4 1" 1" C4 1" 1-1/4" AND 2 2 0 GND IG COPPER H2P1 Ir ( ) # / / I XFMR Impedance (%): 5.32 % 3-PH SUBMERSI YES 85 1 4 8 2 6 A5 1" 1-1/4" B5 1-1/4" 1-1/4" C5 1-1/4" 1-1/4" I I EACH IN 2-1/2" C. i TRANSFORMER SIZE: 2500 KVA xFMR? NO OM36PE PI; 100 1 3 8 1 6 A6 1" 1-1/4" B6 1-1/4" 1-1/4" C6 1-1/4" 1-1/2" 1 i OR 115 1 2 6 1/0 4 A7 1-1/4" 1-1 4" B7 1-1/4" 1-1/2" C7 1-1/4" 1-1/2" 1 1 10,064 * (3) SETS OF (4) 4 kcmil 3,001 I Secondary VOLTAGE(L to L): 480 v WYE off BANK? NO 9 / I AND (2) #4/0 GND IG ALUMINUM 130 1 1 6 2/0 4 A8 1-1/4" 1-1/2" B8 1-1/2" 2" C8 1-1/2" 2" I 9,517 i EACH IN 3" C. i 1 I 150 1 1/0 6 3/0 4 A9 1-1/2" 1-1/2" B9 1-1/2" 2" C9 2" 2" I I BOCAOX TEDCINTEDCTTYP MS THAT ARE VAULT--> VAULT ( or Pole --> Pole) SECONDARY FROM MINIO-V I Secondary Wire LENGTH 60 Feet WIRE SIZE V 12,20112 175 1 2/0 6 4/0 4 A10 1-1/2" 2" 610 2" 2" C10 2" 2" BACKBOARD IR ----- PANEL PANEL PANEL 9 517 Number of SECONDARY RUNS: 8 Run(s)of: 750 QX UG REF 2-EM1 �- L2D1 L2B L2D2 1 1 200 1 3/0 6 250kcmil 4 A11 2" 2" Bit 2" 2-1/2" C11 2" 2-1/2" I 1 1 Secondary WIRE Resistance R: 0.0286 Ohms/1000' / ^' �/1 230 1 4/0 4 300kcmil 2 Al2 2" 2" B12 2-1/2" 2-1/2" C12 2-1/2" 2-1/2" I STORE SIGNAGE & i 1 1 SecondaryWIRE Reactance X: 0.0264 Ohms/1000' TENANT SIGNAGE Cl -� L_ J L__J 6 (4) #4/0 AND (2) #2 GND/IG EDC2 WILL BE SHIPPED IN SEPARATE SPLITS. 250 1 250kcmil 4 350kcmil 2 A13 2" 2-1/2" 613 2-1/2" 2-1/2" C13 2-1/2" 2-1/2" 225A-3P I REF 1-E2 BRKR / COPPER IN 2-1/2" C. ASSEMBLE SECTIONS AND TERMINATE FURNISHED 300 2 1/0 4 3/0 2 A14 1-1/2" 1-1/2" B14 2" 2" C14 2" 2" * C8 CS * OR FEEDER CABLING BETWEEN SECTIONS. FEEDERS VAULT ( or Pole) --> PANEL SECONDARY or Svc Drop) 350 2 2/0 3 4/0 1 A15 1-1/2" 2" B15 2" 2" C15 2" 2-1/2" 1 (4) 300kcmil AND (2) #1/0 IDENTIFIED WITH ASTERISK (*) REFER TO EDC Service Wire LENGTH: 0Feet WIRE SIZE NEMA 1, 30A 4P, 120V 2,097 GND IG VENDOR SHOP DRAWINGS FOR FINAL M 380 1 500kcmil 3 750kcmil 1 A16 2-1/2" 3" 816 3" 3-1/2" C16 3" 3-1/2" COIL MECHANICALLY HELD 1 2,764 5,489 1 / EDU/ CONNECTION REQUIREMENTS Number of Service RUNS: 8 Run(s)of: 750 QX UG ONE- LINE ALUMINUM IN 2-1/2" C. POWERWALL 400 2 3/0 3 250kcm it 1 A17 2" 2" 617 2" 2-1/2" C17 2" 2-1/2" _- _- _ _ _ _ _ - _ _ _ _ - _ _ _ _ _ _ -_ - _- _-_- _ _ _ Service WIRE Resistance R: 0.0286 Ohms/1000' DIAGRAM, 460 2 4/0 2 300kcmil 1/0 A18 2" 2-1/2" 618 2-1/2" 2-1/2" C18 2-1/2" 2-1/2" IN Service WIRE Reactance X: 0.0264 Ohms/1000' DETAILS 500 2 250kcmil 2 350kcmil 1/0 At9 2" 2-1/2" 819 2-1/2" 2-1/2" C19 2-1/2" 2-1/2" g6 C3 812 2,172 1 600 2 350kcmil 1 500kcmil 2/0 A20 2-1/2" 2-1/2" B20 2-1/2" 3" C20 3" 3" AND 760 2 500kcmil 1/0 750kcmil 3/0 A21 2-1/2" 3" B21 3" 3-1/2" C21 3" 3-1/2" PANELL2D3 MAXIMUM FAULT CURRENT*: 533347 Amps 177/o SCHEDULES 800 3 300kcmil 1/0 400kcmil 3/0 A22 2-1/2" 2-1/2" B22 2-1/2" 2-1/2" C22 2-1/2" 3" PANEL PANEL 2-SECT. PANEL LRC LRX LFS 'Maximum fault current based upon transformers/conductors sized for 100% ectrical anel raU NOTES: 1. CONDUIT SIZE BASED ON CONDUCTOR PROPERTIES LISTED IN THE CURRENT NEC EDITION, CHAPTER 9, TABLES 5 AND 5A, AND Based on a panel size 3000 Ames Y CONDUIT AREAS LISTED CHAPTER 9, TABLE 4 FOR EMT WITH 40% FILL, OTHER CONDITIONS MAY REQUIRE A LARGER CONDUIT, (RECYCLING (PHARMACY) FOOD TENANT 0 N E - LINE D I A G R A M a SIZED PER NEC. ( ) a CENTER) (ROTISSERIE NTS To Print This Page: "Ctrl M°and choose"Print 3-Phase Da ° = 812 0 2. COORDINATE SIZE, TYPE , AND QUANTITY OF LUGS WITH EDC VENDOR PREP) SHEET: Q E4 0 PANELBOARD NOTES ( ) (1) TERMINATE GROUND ON ISOLATED GROUND BUS. (2) INSTALL LOCKING DEVICE FURNISHED WITH PANELBOARD (LOCK-OFF FOR MAINTENANCE). (3) INSTALL LOCKING DEVICE FURNISHED WITH PANELBOARD (LOCK-ON FOR CRITICAL LOAD). (4) GFI BREAKER FOR PERSONNEL PROTECTION (5 mA). (5) GF] BREAKER FOR EQUIPMENT PROTECTION (30 mA). (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR VOLTAGE DROP. SIZE EQUIPMENT GROUNDING CONDUCTOR PROPORTIONALLY PER NEC. (7) REFER TO ONE-LINE DIAGRAM FOR AVAILABLE FAULT CURRENT FOR INTERRUPTING RATINGS. (8) REFER TO ONE-LINE DIAGRAM FOR WIRE SIZES. wo00, (9) FACTORY WIRED TO LOAD. D 23 ' _We oN� LJ o « Z -z (10) REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. �F�<z�oJw�v aoU (11) THRU CONTACTOR. F_xa�zZDW amo\�"W"�wz��a y Vw W4W� (X) DESIGNATES "SMART" BREAKER. zo oggot O680a 'Koo�o wiz oaz oz F zvaiaoj�5zo <az< Q ,j!jmd"3wx FQo3 wa J QQFQF-ZF 4WWW W 0i.0.wwo NJ d OOO wtn¢�¢�0=0WOW H NNK NOS'-QOZW�W WJO �ODNZ�JwQInQK R'Q'r Z) HI �W e W WZ H1 A PANELBOARD H2A PANELBOARD z WZ oxo 480V, 3PH, 3W 480V 3PH, 3W =W Ww M.L.O. 404ATv1.L.0. (7) AIC, 2ATED (7) AIC, FULLY RATED o0 �2 SERVES: HVAC GROUND BUS SERVES: HVAC GROUND BUS U LOCATION: EDC1 LOCATION: EDC2 PANEL PROVIDED WITH EDC SURFACE MO NTJ PANEL PROVIDED WITH EDC SURFACE MOUNT DESCRIPTION WIRE BRKRPL VA PL RKR WIRE DESCRIPTION DESCRIPTION WIRE RKR PL KVA PLBRK WIRE DESCRIPTION A A 1 RTU11 (6) #8 30 3 6.73 12.91 1 3 50 #4_ RTU12 (6) 2 1 RTU1 (6) #8 30 3 6.73 6.73 1 3 30 #10 RTU2 2 10 TON 6.73 12.91 20 TON 10 TON 6.73 6.73 10 TON O O p to 6.73 12.91 6.73 6.73 p1 �^ , 3 RTU13 #12 15 3 2.49 12.91 3 50 #6 RTU14 (6) 4 3 RTU3 #12 20 3 3.27 3.27 3 20 #12 RTU4 4 O 3 TON 2.49 12.91 20 TON 5 TON 3.27 3.27 5 TON 2.49 12.91 3.27 3.27c2l; Lo 5 RTU15 (6) #4 50 3 12.91 12.91 3 50 #4 RTU16 (6) 6 5 RTU5 #12 20 3 3.27 3.27 3 20 #12 RTU6 6 rn-J] o 20 TON 12.97 72.97 20 TON 5 TON 3.27 3.27 0 5 TON w 12.91 12.91 1 3.27 3.27 7 RTU17 (6) #6 50 3 12.91 6.73 3 30 #8 RTU18 (6) 8 7 RTU7 #12 15 3 2.49 12.91 3 50 #8 RTU8 8 �+V ® O 20 TON 12.91 6.73 10 TON 3 TON 2.49 12.91 20 TON �V 12.91 6.73 2.49 12.91 " LTJ 9 RTU19 #12 20 3 3.27 3.27 3 20 #12 RTU20 10 9 RTU9 #8 50 3 12.91 12.91 3 50 #8 RTU10 10 oo� m 5 TON 3.27 3.27 5 TON 20 TON 12.91 12.91 20 TON O o 3.27 3.27 12.91 12.91 cf) o 11 RTU21 #12 20 3 3.27 3.27 3 20 #12 RTU22 12 11 SPACE SPACE 12 0 5 TON 3.27 3.27 5 TON EE � w 13 SPACE SPACE 14 13 SPACE SPACE 14 z 15 SPACE SPACE 16 15 SPACE SPACE 16 p ti 17 SPACE SPACE 18 17 SPACE SPACE 18 ISSUE BLOCK TOTAL 93.61 93.61 93.61 KVA TOTAL 67.79 67.79 67.79 KVA PER NEC ARTICLE 220 338 338 338 AMPS PER NEC ARTICLE 220 245 245 245 AMPS TOTAL LOAD 280.84 KVA 338 JAMPS TOTAL LOAD 203.36 KVA 245 AMPS FEEDER LOADI 282.46 KVA 340 AMPS FEEDER LOADI 204.98 KVA 1 247 JAMPS I � L H1 P1 POWER SWITCHING PANELBOARD H213 PANELBOARD 480/277V, 3PH, 4W 480/277V, 3PH, 4W SERVES: LIGHTING 225A, M.L.O. SERVES: 48DV DISTRIBUTION 600A, M.L.O. LOCATION: EDC1 (7) AIC, SERIES RATED LOCATION: EDC2 (7) AIC, SERIES RATED PANEL PROVIDED WITH EDC GROUND BUS PANEL PROVIDED WITH EDC GROUND BUS SURFACE MO NTJ SURFACE MOUNT KVA K A V DESCRIPTION WIRE RK PL PL RK B WIRE DESCRIPTION DESCRIPTION WIRE RKRPL PL RK WIRE DESCRIPTION A EMS CONTROLLER SPACE 1 PANEL H2P1 (9) (8) 100 3 12.09 10.28 3 50 #6 8005L PAN WASHER (2) 2 POWER SUPPLY 3 480/277/3 15.24 10.28 37.1 A, 480/3 4 5 11.18 1 10.28 6 CHECKED BY: 1 GM SALES FLOOR LTG (6,X) #10 20 1 3.25 D.26 1 20 SECURITY LIGHTING (X) 2 7 SPACE 1 8.59 3 40 #8 D028A FRYER (2) 8 3 GM SALES FLOOR LTG (6,X) #10 20 13.25 2.59 1 20 RECEIVING LIGHTING 4 9 8.59 31.0 A, 480/3 10 DRAWN BY: TLC 5 GM SALES FLOOR LTG (6,X) 10 20 1 3.25 1 2.74 1 20 RECEIVING LIGHTING 6 11 8.59 12 7 GM SALES FLOOR LTG (6,X) #10 20 1 3.25 1.96 1 1 20 COOLER / STOCKROOM LTG 8 13 TRANSFORMER T2D (9) (8) 350 3 63.82 SHUNT-TRIP BREAKER 14 FILE NAME: E4.1 9 GM SALES FLOOR LTG (6,X) #10 20 1 1 3.36 2.08 1 20 HALLWAY LIGHTING 10 15 225 KVA, 480/3 66.68 11.92 3 60 #6 D028B FRYER (2) 16 PROTO CYCLE: 012712 11 GM SALES FLOOR LTG (6,X) #10 20 1 13.36 2.09 1 1 20 1 IREAR OFFICE LIGHTING 121 171 1 65.83 11.92 1 143.0 A, 480/3 18 13 GM SALES FLOOR LTG (6,X) #10 20 1 3.36 1 20 SPARE (X) 14 19 SUB-METERING (3) 15 3 0.14 11.92 20 DOCUMENT DATE: 041012 15 GM SALES FLOOR LTG (6,X) #10 20 1 3.36 1 20 SPARE(FUTURE WINE LTG) (X) 16 21 (VOLTAGE REFERENCE) 0.14 SHUNT-TRIP BREAKER 22 17 GM SALES FLOOR LTG 6,X) #10 20 1 3.02 1 20 SPARE 18 23 0.14 11.92 3 60 #6 D028B FRYER (2) 24 19 GROC. SALES FLOOR LTG (6,X) #10 20 14 1 20 SPARE 20 25 TRANSFORMER TFS (9) (8) 100 3 15.22 11.92 43.0 A, 480/3 26 21 GROC. SALES FLOOR LTG (6,X) #10 20 1 2.44 1 20 SPARE 22 27 75 KVA, 480/3 13.10 11.92 28 2.4 23 GROC. SALES FLOOR LTG (6,X) 10 20 1 2.44 SPACE 24 29 11.90 SHUNT-TRIP BREAKER 30 25 GROC. SALES FLOOR LTG (6,X) #10 20 1 1r4��� SPACE 26 31 SPACE SPACE 32 27 GROC. SALES FLOOR LTG (6,X) #10 20 1 2.44 SPACE 28 33 34 29 GROC. SALES FLOOR LTG (X) 20 1 1.51 SPACE 30 35 36 31 SPACE SPACE 32 37 SPACE SPACE 38 33 SPACE SPACE 34 39 40 35 EMERGENCY LIGHTING 3) 20 1 0.29 SPACE 136 41 142 TOTAL 16.95 19.52 18.70 KVA TOTAL 133.97 137.86 131.76 KVA PER NEC ARTICLE 220 61 70 67 AMPS PER NEC ARTICLE 220 484 498 476 AMPS TOTAL LOAD 55.16 KVA 66 jAMPS TOTAL LOAD 403.58 KVA 485 AMPS FEEDER LOAD 68.95 KVA 83 1AMPS FEEDER LOAD 327.55 JKVA 394 AMPS H1 P2 POWER SWITCHING PANELBOARD H2P1 POWER SWITCHING PANELBOARD 480/277V, 3PH, 4W 480/277V, 3PH, 4W SERVES: LIGHTING. 225A, M.L.O. SERVES: LIGHTING 225A, M.L.O. (LOCATION: EDC1 (7) AIC, SERIES RATED( (LOCATION: EDC2 (7) AIC, SERIES RATED I I PANEL PROVIDED WITH EDC GROUNDBUS PANEL PROVIDED WITH EDC GROUND BUS d n DRAa-_ SURFACE MOUNT SURFACE MOUNT DESCRIPTION WIRE BRKRPL KVA PL RKWIRE DESCRIPTION DESCRIPTION WIRE BRK PL VA PL RK WIRE DESCRIPTION �? 72336PE A B C Ri I A B C EMS CONTROLLER 1 3 30 #10 TVSS (3,9) EMS CONTROLLER 3 30 #10 TVSS (3,9) m POWER SUPPLY (SURGE SUPPRESSION) POWER SUPPLY (SURGE SUPPRESSION) �OL�OR GON 20� 1 GM SALES FLOOR LTG (6,X) #10 20 1 3.25 1 2.03 1 1 20 #10 PERIMETER LIGHTING (6,X) 2 1 VESTIBULE/AP OFFICE LTG 20 1 1.67 0.79 1 20 PERIMETER LIGHTING (X) 2 NPP 3 GM SALES FLOOR LTG (6,X) #10 20 1 3.36 2.03 1 20 #10 PERIMETER LIGHTING (6,X) 4 3 FRONT OFFICE LIGHTING 20 1 2.51 0.79 1 20 PERIMETER LIGHTING (X) 4 �! 5 GM SALES FLOOR LTG (6,X) #10 20 1 1 3.36 2.05 1 20 #10 PERIMETER LIGHTING (6,X) 6 5 IPHARMACY LIGHTING (X) 1 20 11 1.08 1 0.76 11 20 I PERIMETER LIGHTING (X) 6 PIRES:06/3012013 7 GM SALES FLOOR LTG (6,X) #8 20 1 3.60 SPACE 8 7 PHARMACY SALES LIGHTING 20 1 1.05 1.59 1 20 I BAKERY SALES LIGHTING 8 9 GM SALES FLOOR LTG (6,X) #8 20 1 3.60 SPACE 10 9 TENANT PERIMETER LTG (X) 20 1 1 3.00 D.82 1 20 PRODUCE LIGHTING 10 11 GM SALES FLOOR LTG (6,X) #8 20 1 3.60 I ISPACE 121 11 WAL-MART SIGN (X) 20 2 1.28 F 1.68 1 20 DELI LIGHTING 12 13 GM SALES FLOOR LTG (6,X) #8 20 1 3.83 SPACE 14 13 480/1 1.28 1 0.99 1 1 20 RECYCLE LIGHTING 14 75 GM SALES FLOOR LTG (6,X) #8 20 1 3.83 SPACE 16 15 WAL-MART SIGN (X) 20 2 1 1.28 1.37 1 20 BAKERY/FREEZER LTG 16 17 GM SALES FLOOR LTG (6,X) #8 20 1 3.83 SPACE i8 17 480/1 1 1.28 1 0.19 1 20 FLAG POLE LIGHT 18 19 GM SALES FLOOR LTG (6,X) #8 20 1 3.83 SPACE 20 19 PARKING LOT SEC LTS (X) 20 2 0.43 1 1 20 SPARE 20 PANELBOARD 21 SPARE (X) 20 1 SPACE 22 21 480/1 0.43 1 SPACE 22 SCHEDULES 23 SPARE (X) 20 1 SPACE 24 23 PARKING LOT LIGHTING (X) 20 2 2.09 SPACE 24 25 SPACE SPACE 26 25 480/1 2.09 SPACE 26 27 SPACE SPACE 28 27 PARKING LOT LIGHTING (X) 20 2 2.84 SPACE 28 29 SPACE 1.01 2 20 (10) PARKING LOT LIGHTING (X) 130 29 480/1 1 1 2.84 SPACE 30 31 SPACE 1.01 t1480/1 31 PARKING LOT LIGHTING (X) 20 2 2.22 SPACE 32 33 SPACE 0.21 2 20 (10) TRUCKWELL SECURITY LTG (X) 1332 4 33 48D/1 2.22 SPACE 34 35 EMERGENCY LIGHTING (3) 20 11 0.39 1 0.21 480/1 36 35 SPACE 1 20 1 ICONTACTOR CONTROL (9) 136 TOTAL 17.53 13.03 14.45 KVA TOTAL 12.09 15.24 11.18 KVA Y PER NEC ARTICLE 220 63 47 52 AMPS PER NEC ARTICLE 220 44 55 40 AMPS Q a TOTAL LOAD 45.01 KVA 54 AMPS TOTAL LOAD 38.51 KVA 46 AMPS FEEDER LOAD 56.26 KVA 68 JAMPS FEEDER LOAD 48.14 KVA 58 AMPS SHEET: Q E4 . 1 0 PANELBOARD NOTES ( ) Ll D1 PANELBOARD (1) TERMINATE GROUND ON ISOLATED GROUND BUS. (2) INSTALL LOCKING DEVICE FURNISHED WITH SECTION #1: BREAKERS 1-30 208/12OV, 3PH, 4W PANELBOARD (LOCK-OFF FOR MAINTENANCE). SERVES: MISC. 120V POWER SECTION #2: BREAKERS 31-60 300A, M.C.B. (3) INSTALL LOCKING DEVICE FURNISHED WITH LOCATION: EDC1 (7) AIC, SERIES RATED PANELBOARD (LOCK-ON FOR CRITICAL LOAD). PANEL PROVIDED WITH EDC GROUND BUS (BOTH SECTIONS) (4) GFI BREAKER FOR PERSONNEL PROTECTION TWO-SECTION PANEL ISOLATED GROUND BUS (BOTH SECTIONS) (5 mA). WITH FEED-THRU LUGS SURFACE MOUNT V (5) GFI BREAKER FOR EQUIPMENT PROTECTION DESCRIPTION WIRE BRKRPL PLBRKR WIRE DESCRIPTION (30 mA). 1 DOCK LEVELER (6) #10 20 1 1.52 A 6.88 3 100 #3 BUSWAY B1_1A 2 (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR 3 DOCK LEVELER (6) #10 20 1 1.52 7.36 208/120/3 4VOLTAGE DROP.L2B PANELBOARD CONDUCTOR PROPORTIONALLY IZE Y PER NEENT C. 5 RECEIVING RECEPTACLES 20 1 1 0.91 7.66 6 208/12OV, 3PH, 4W (7) REFER TO ONE-LINE DIAGRAM FOR AVAILABLE 7 RECEIVING RECEPTACLES 20 1 0.72 6.92 3 100 #3 BUSWAY BL1B 8 SERVES: 208V DISTRIBUTION BOCA, M.C.B. FAULT CURRENT FOR INTERRUPTING RATINGS. 9 RECEIVING RECEPTACLES (6) #8 20 1 1.08 7.90 208/120/3 10 LOCATION: EDC2 (7) AIC, SERIES RATED (8) REFER TO ONE-LINE DIAGRAM FOR WIRE SIZES. �� 11 RECEIVING RECEPTACLES (1) 20 1 0.18 8.09 12 PANEL PROVIDED WTH EDC GROUND BUS w o OOH 9 FACTORY WIRED TO LOAD. 0 <z WO z< 13 RECYCLING DESK (1) 20 1 0.18 1.44 1 20 #8 VENDING MACHINE (6) 14 ISOLATED GROUND BUS ( ) D Wv tom z 15 WALKIE-STACKERS 20 1 0.36 1.44 1 20 8 VENDING MACHINE 6 16 SURFACE MOUNT w 'Pisa << z ��z # ( ) (10) REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. �QazoonWJwW��wo 17 I.C. / PALLET JACKS 20 1 0.54 1.44 1 20 #8 VENDING MACHINE (6) 18 V a >NOWmm�zlz 'W DESCRIPTION WIRE BRKRPL PL RK WIRE DESCRIPTION (11) THRU CONTACTOR. o �NHow- z�om 19 PAYSTUB KIOSK 20 1 0.18 1.44 1 20 #8 VENDING MACHINE (6) 20 C 21 JIB CRANE 20 1 1.08 1.44 1 20 #8 VENDING MACHINE (6) 22 1 PANEL L2D1 (1,9) (8) 125 3 11.01 SPACE 2 (X) DESIGNATES "SMART" BREAKER. 3�Qooww 00,00 23 SPARE 20 1 1.44 1 20 #8 VENDING MACHINE (6) 24 3 208/120/3 9.56 4 zNooHa�z�aaoz< 25 SPARE 20 1 1.44 1 20 #8 VENDING MACHINE (6) 26 5 10.05 6 J a<mR"«zF ����ow< 27 SPARE 20 1 SPACE 28 7 PANEL L2D2 (1,9) (8) 125 3 9.65 SPACE 8 000Ow WWWHM �W 000 s ¢ O-OwOI d NNO�p���O¢Vdwn~ 29 BREAKROOM REC/I.C. (6) #8 20 1 1.08 SPACE 30 9 208/120/3 11.45 10 U) F_.9�^zS n2<0<¢M<o 11 10.01 12 31 RECIRC PUMP 20 1 0.09 0.92 1 15 UH (RECEIVING) 32 13 PANEL LRX (1) (8) 60 3 3.77 SPACE 14 33 SPARE 20 1 0.36 1 20 BIKE ASSEMBLY 34 15 208/120/3 3.23 16 ZNII 35 SPARE 20 1 0.54 1 20 BIKE ASSEMBLY 36 17 3.47 18 ON - 0 37 SPARE 20 1 1 20 SPARE 38 19 BUSWAY BL2A (1) #3 100 3 7.82 SPACE 20 HW ^ a W 39 SPARE 20 1 1 20 SPARE 40 21 208/120/3 9.03 22 W $ 41 SPARE 20 1 1 20 SPARE 42 23 9.46 24 z M 43 FLOOR SCRUBBER (6) #10 20 1 1.20 0.82 1 20 72A/878 ELECTR./DATA (1) 44 25 BUSWAY BL28 #3 100 3 4.22 SPACE 26 �� w 45 FLOOR SCRUBBER (6) #10 20 1 1.20 1.22 1 20 #8 RTU17 & 18 (6) 46 27 208/120/3 4.84 28 ~ ZZ Wao ® o z WZ �„zo r 47 FLOOR SCRUBBER (6) #10 20 1 1.20 0.18 1 15 DATA LOGGER (1,9) 48 29 4.10 30 F T.W 49 CLAIMS 20 1 1.08 0.72 1 20 EDC1 RECEPTACLES (9) 50 31 PANEL L2D3 (8) 225 3 19.12 SPACE 32 L2D3 PANELBOARD - 51 TELXON CHARGER 20 1 0.60 0.18 1 20 EDC1 EMS EQUIPMENT (3,9) 52 33 208/120/3 21.96 34 W 53 MOVABLE RACKS (2,6) #10 20 1 1.23 1.26 1 20 TELEPHONE BOARD (1,3,9) 54 35 22.08 36 SECTION #1: BREAKERS 1-30 208/120V, 3PH, 4W p F 55 WH (JANITOR) (2,6) #8 30 3 1.50 1.60 1 20 ALARM BOARD (1 9) 56 37 PANEL LRC (8) 100 3 8.22 SPACE 38 SERVES: : ROCESSERIE R SECTION #2: BREAKERS 31-60 225,0 M.L.O. LOCATION: ROTISSERIE PREP 10,000 AIC 57 4.5 KW, 208/3 1.50 1.58 1 20 ALARM BOARD (1,3,9) 58 39 208/120/3 6.62 40 PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS (BOTH SECTIONS) 59 1.50 1.58 1 20 ALARM BOARD (1,3,9) 160 41 6.66 142 TWO-SECTION PANEL TOTAL 28.65 28.82 28.83 KVA TOTAL 63.82 66.68 65.83 KVA WITH FEED-THRU LUGS FLUSH MOUNT VA PER NEC ARTICLE 220 239 240 240 AMPS PER NEC ARTICLE 220 532 556 549 AMPS DESCRIPTION WIRE BRK PL A K PL RKR WIRE DESCRIPTION O O ZO TOTAL LOAD 86.29 KVA 240 AMPS TOTAL LOAD 196.32 KVA 545 AMPS 1 I_FAK DETECTION (3) 20 1 0.10 1 20 SPARE 2 �� �a FEEDER LOAD 83.79 KVA 233 CAMPS I I FEEDER LOADS 165.42 KVA 459 �PIvIPS I 3 D004 SCALE / DELI RECEPTS 20 1 0.72 0.36 1 20 R/0 WATER FILTRATION 4 ....... O r, 5 D004 SCALE / DELI RECEPTS 20 1 0.90 0.36 1 20 R/O WATER FILTRATION 6 7 D004 SCALE / DELI RECEPTS 20 1 0.90 1 20 SPARE 8 L1 D2 PANELBOARD L2D1 PANELBOARD 9 Do07.1 SLICER 20 1 0.79 1.22 1 20 #8 RTU1 & AHU1 RECEPTS (6) 10rL-1 Ln F 208/12OV, 3PH; 4W / 11 DO07.1 SLICER 20 1 0.79 0.18 1 20 PRODUCE MISTING 12 O- O 208 120V, 3PH, 4W Q � C� SERVES: MISC. 120V POWER 225A, M.L.O. SERVES: MISC. 120V POWER 225A, M.L.O. 13 D007 SLICER 20 1 0.79 1 20 SPARE i ' � R LOCATION: CBL ROOM (7) AIC, SERIES RATED LOCATION: EDC2 10,000 AIC 15 0005 WRAPPER 20 1 0.96 1 20 SPARE 16 ((Iyl O O PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS PANEL PROVIDED WITH EDC GROUND BUS 17 D017 MICROWAVE 20 1 1.58 1 20 SPARE 18 ISOLATED GROUND BUS ISOLATED GROUND BUS 19 DELI FREEZER HTR (2,5) 20 1 0.26 SPACE 20 LLJ FLUSH MOUNT SURFACE MOUNT 21 EH1 LIGHTS / CONTROLS (2) 15 1 0.52 SPACE 22 � m V KVA 23 EFH1 (2,6 #10 20 1 1.56 2.97 3 35 #8 D059F ROTISSERIE 24 O o DESCRIPTION WIRE RKRPL A PLBRK WIRE DESCRIPTION DESCRIPTION WIRE RK PL PLBRK WIRE DESCRIPTION 25 EH2 LIGHTS/CNTRLS (2) 15 1 0.72 2.97 24.7, 208/3 26 1 CBL ROOM RECEPTS 20 1 1.08 1.08 1 20 BREAK RM REC/I.C. 2 1 WM GREETER CABINET 20 1 0.54 0.43 1 20 EDC2 RECEPT / EF (EDC2) 2 27 EFH2 (2) 20 1 1.56 2.97 28 O 3 MANAGER'S DESK RECEPTS 20 1 1.08 1.80 1 20 #10 TOASTER (6) 4 3 EAS (3) 20 1 0.57 1.66 1 20 REMOTE ALARM BOARD (1,3) 4 29 POULTRY COOLER HTR (2,5) 20 1 0.22 D059F SHUNT-TRIP BREAKER 30 ~ 'I 5 AD OFFICE RECEPTS 20 1 0.90 1.36 1 20 COFFEE MAKER 6 5 VENDING MACHINES (6 10 20 1 1.44 0.51 1 20 STORE FRONT SIGN (2,11 6 7 AD OFFICE RECEPTS 20 1 0.72 1.81 1 20 #10 ICE MACHINE (2,6) 8 7 VENDING MACHINES (6) #10 20 1 1.44 1.00 1 20 #8 TENANT SIGNAGE (2,6,11) 8 31 P005 WRAPPER 20 1 0.96 2.97 3 35 #8 D059F ROTISSERIE 32 9 PERSONNEL RECEPTS 20 1 1.44 1.63 1 20 #10 MICROWAVE (6) 10 9 VENDING MACHINES (6) #10 20 1 1.44 1 20 SPARE 10 33 P004 SCALE / RECEPTS 20 1 0.54 2.97 24.7, 208/3 34 z 11 PERSONNEL PRINTER 20 1 1.20 1.63 1 20 #10 MICROWAVE (6) 12 11 WATER RETURN BIN 20 1 0.18 0.18 1 20 EXTERIOR RECEPT 12 35 ROLLSEAL DOOR 20 1 1.20 2.97 36 1,3 TRAINING/UPS/UPC RECEPTS 20 1 0.54 1.44 1 20 REFRIGERATOR 14 13 GM AMUSEMENT 20 1 1.44 0.18 1 20 EXTERIOR RECEPTACLE 14 37 SPARE 20 1 D059F SHUNT-TRIP BREAKER 38 p 15 INVOICING RECEPTS 20 1 1.08 1.44 1 20 REFRIGERATOR 16 15 GM AMUSEMENT 20 1 1.44 0.08 1 15 SIDEWALK REGISTER (1) 16 39 SPARE 20 1 2.97 3 35 #8 D059F ROTISSERIE 40 17 INVOICING RECEPTS 20 1 0.72 1.44 1 20 REFRIGERATOR 18 17 PET TAGS 20 1 1.44 0.54 1 20 EXTERIOR RECEPTACLES 18 41 SPARE 20 1 2.97 24.7, 208/3 42 19 HAND DRYER (2) 20 1 1.14 SPACE 20 19 MOTORIZED CARTS 20 1 0.54 1.22 1 20 #10 RTU6-20 RECEPTS (6) 20 43 SPACE 2.97 44 ISSUE BLOCK 21 HAND DRYER (2) 20 1 1.14 SPACE 22 21 DOOR OPERATOR (2) 20 1 0.60 1 20 SPARE 22 45 SPACE D059F SHUNT-TRIP BREAKER 46 23 RESTROOM LIGHTING 20 1 0.43 SPACE 24 23 DOOR OPERATOR (2) 20 1 0.60 1 20 SPARE 24 47 SPACE 2.97 3 35 8 D059F ROTISSERIE 48 25 UPC EQUIPMENT (1) #10 30 1 2.40 1.80 2 30 #10 IBM BLADECENTER (3) 26 25 DOOR OPERATOR (2) 20 1 0.60 1.94 1 20 VENDING MACHINES (6) 26 49 R121B SERVICE CASE (2) #10 30 3 2.22 2.97 24.7, 208/3 50 27 EWC'S (4) 20 1 0.72 1.80 3.6 KW, 208/1 28 27 DOOR OPERATOR (2) 20 1 0.60 2.04 1 20 VENDING MACHINES (6) 28 51 18.5 A, 120/208/3 2.22 2.97 52 29 HIRING KIOSK (1) 30 1 0.36 3.41 2 50 #6 PANEL L1U (1,3) 30 29 MONITOR RACK SYSTEM 20 1 0.40 2.42 1r2D VENDING MACHINES (6) 30 53 222 D059F SHUNT-TRIP BREAKER 54 31 HIRING KIOSK (1) 20 1 0.36 2.85 208/120/1 32 31 AP OFFICE RECEPTACLES 20 1 1.08 1 SPARE 32 55 R122 SELF MULTI-DECK (2) 20 3 1.20 0.09 1 20 DELI CAN / PENDANT LTG 56 33 EF (REAR RESTRM) 20 1 0.86 2.70 2 50 #2 PANEL L2U (1,3,6) 34 33 VEST/RESTROOM LTG 20 1 0.37 1 SPARE 34 57 10.0 A, 120/208/3 120 SPACE 58 35 AC (REAR RESTRM) 20 1 1.73 1.32 208/120/1 36 35 REDBOX 20 1 0.73 1 20 SPARE 36 59 i.20 SPACE 60 37 SPARE 20 1 3.59 3 100 #3 BUSWAY BL1C (1) 38 37 COINSTAR 20 1 0.60 20 SPARE 38 TOTAL 19.12 21.96 22.08 KVA 39 SPARE 20 1 3.64 208/120/3 40 39 CART STOR. RECEPT/I.C. 20 1 0.36 0.40 1 20 RH (CART STORAGE) 40 PER NEC ARTICLE 220 159 183 184 AMPS 41 RTU19-22 20 1 1.22 4.12 42 41 CONTACTOR Cl CONTROL (9) 20 1 0.01 1.60 1 30 #10 UH (VESTIBULE) 42 TOTAL LOAD 63.16 KVA 175 AMPS TOTAL 18.81 19.34 19.84 KVA TOTAL 11.01 9.56 10.05 KVA FEEDER LOAD 44.34 KVA 123 AMPS PER NEC ARTICLE 220 157 161 165 AMPS PER NEC ARTICLE 220 92 80 84 AMPS TOTAL LOAD 57.99 KVA 161 AMPS TOTAL LOAD 30.62 KVA 85 AMPS FEEDER LOAD 54.19 KVA 150 AMPS FEEDER LOAD 27.36 KVA 76 AMPS LRC PANELBOARD 208/120V, 3PH, 4W SERVES: RECYCLING CENTER 100A, M.L.O. L1 D3 PANELBOARD L2D2 PANELBOARD LOCATION: RECYCLING CENTER 10,000 AIC 208/12OV, 3PH, 4W 208/12OV, 3PH, 4W PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS SERVES: MISC. 120V POWER 225A, M.L.O. SERVES: MISC. 120V POWER 225A, M.L.O. SURFACE MOUNT CHECKED BY: LOCATION: BAKERY UTILITY 10,000 AIC LOCATION: EDC2 10,000 AIC KVA PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS PANEL PROVIDED WITH EDC GROUND BUS DESCRIPTION WIRE RKRPL PL RK WIRE DESCRIPTION DRAWN BY: TLC ISOLATED GROUND BUS A FILE NAME: E4.2 FLUSH MOUNT SURFACE MOUNT 1 RECYCLING MACHINES 20 3 0.48 2.00 1 25 #10 WH (RECYC. CNTR) (2) 2 KVA KVA 3 4.0 A, 208/3 0.48 0.92 1 15 UH (RECYC. CNTR) 4 PROTO CYCLE: 012712 DESCRIPTION WIRE RKRPL PL RKR WIRE DESCRIPTION DESCRIPTION WIRE RKRPL PL RK WIRE DESCRIPTION 5 0.48 0.54 1 20 INSECT CONTROL 6 1 B020/BO21/BO24/BO25/BO28 20 1 0.72 A 0.53 C 3 20 B065G RACK OVEN (2) 2 1 COURTESY DESK RECEPTS 20 1 1.44 A 0.18 1 20 IRRIGATION CONTROLLER 2 7 RECYCLING MACHINES 20 3 1.20 0.70 1 20 EF (RECYCLE CENTER) 8 DOCUMENT DATE: 041012 3 BAKERY RECEPTS / I.C. 20 1 1.08 0.53 4.4 A, 208/3 4 3 COURTESY DESK RECEPTS 20 1 1.08 1.08 1 20 COUNTING RECEPTS 4 9 10.0 A, 208/3 1.20 0.18 1 20 RECEPTACLE 10 5 B007 BREAD SLICER 20 1 1.18 0.53 6 5 EF (FRONT TLT) (6) #8 20 1 1.18 0.72 1 20 CASH RECEPTS 6 11 1.20 0.60 1 20 DOOR OPERATOR (2) 12 7 8049 DONUT MACHINE #6 50 2 3.43 1.80 1 20 B065GA OVEN CONTROLS (2) 8 7 RUG DOCTOR 20 1 0.18 0.72 1 20 CASH RECEPTS 8 13 RECYCLING MACHINES 20 3 0.48 1 20 SPARE 14 9 33.0 A, 208/1 3.43 0.96 1 20 92A COFFEE GRINDER 10 9 REGISTRY IG (1) 20 1 0.55 1.OB 1 20 STORE MANAGER'S OFFICE 10 15 4.0 A, 208/3 0.48 1 20 SPARE 16 11 8033 ICING TABLE 15 2 0.90 0.72 1 20 WH GROC. RECIRC PUMPS (2)12 11 ATM MCX RECEPTACLE (1,6) 20 1 0.84 0.48 1 20 EWC'S (4) 12 17 0.48 1 20 SPARE 18 13 1800 W, 208/1 0.90 0.61 1 20 MECH /EF(MECH)/DEODORIZER 14 13 UTILITY BOLLARD 20 1 0.18 1.14 1 20 #10 HAND DRYER (2,6) 14 19 RECYCLING MACHINES 20 3 1.20 SPACE 20 15 TF (BAKERY AROMA) 20 1 0.86 1 20 SPARE 16 15 UTILITY BOLLARD (1) 20 1 0.16 1.14 1 20 #10 HAND DRYER (2,6) 16 21 10.0 A, 208/3 1.20 SPACE 22 17 B018B BAKERY DISPLAY (4 20 1 0.18 1 20 SPARE 18 17 SITE TO STORE RECEPT 20 1 0.18 0.72 1 20 SEASONAL AMUSEMENT 18 23 1.20 SPACE 24 19 GROCERY FREEZER HTRS (2,5) 20 1 0.73 SPACE 20 19 SITE TO STORE RECEPT (1) 20 1 0.09 0.36 1 20 SEASONAL KIOSK IG (1) 20 25 RECYCLING MACHINES 20 3 0.48 SPACE 26 21 LEAK DETECTION (3) 20 1 0.20 SPACE 22 21 SPARE 20 1 0.27 1 20 RECIRC PUMP 22 27 4.0 A, 208/3 0.48 SPACE 28 23 WASTE OIL TANK 20 1 1.84 SPACE 24 23 SPARE 20 1 0.05 1 20 EMS CONTROLLER (1,2) 24 29 0.48 SPACE 30 75_'m004 SCALE / RECEPTS 20 1 0.72 SPACE 26 25 SPARE 20 1 1.50 3 30 #10 WH (GM MECH ROOM) (2) 26 31 RECYCLING MACHINES 20 3 1.20 SPACE 32 27 MEAT COOLER HTRS (2,5) 20 1 0.41 SPACE 28 27 SPARE 20 1 1.50 4.5 KW, 208/3 28 33 10.0 A, 208/3 1.20 SPACE 34 29 ROLLSEAL DOOR 6) 10 20 1 1.20 SPACE 30 29 CULLIGAN WATER 20 1 O.6D 1.50 30 35 1.20 SPACE 36 31 BAKERY CAN / PENDANT LTG 20 1 0.03 SPACE 32 31 ICE BAGGER 20 1 0.24 1.75 1 20 #8 AC (FRONT RESTRM) (6) 32 37 RECYCLING MACHINES 20 3 0.48 SPACE 38 33 IPTV / PRICE VERIFIER 20 1 1.12 SPACE 34 33 ICE MERCHANDISER 20 1 0.97 1.75 1 20 #8 AC (FRONT RESTRM) (6) 34 39 4.0 A, 208/3 0.48 SPACE 40 35 RTU11&13,RACKA,B,C,AHU1(6) #8 20 1 1.22 SPACE 36 35 ICE MAKER #10 30 2 1.87 1 20 SPARE 36 41 0.48 SPACE 42 37 RTU16, AHU1 20 1 1.22 SPACE 38 37 120/208/1 1.87 SPACE 38 TOTAL 8.22 6.62 6.66 KVA 39 SPARE 20 1 SPACE 40 39 ICE MAKER #10 30 2 1.87 SPACE 40 PER NEC ARTICLE 220 68 55 56 AMPS 41 SPARE 20 1 SPACE 42 41 120/208/1 1.87 SPACE 42 TOTAL LOAD 21.50 KVA 60 AMPS TOTAL 10.69 8.59 7.77 KVA TOTAL 9.65 11.45 10.01 KVA FEEDER LOAD 21.73 KVA 60 AMPS I PER NEC ARTICLE 220 89 72 65 AMPS PER NEC ARTICLE 220 80 95 83 AMPS TOTAL LOAD 9705 (VA, 75 AMPS TOTAL LOAD 31.11 KVA 86 AMPS n PRQ FEEDER LOAD 22.79 KVA 63 AMPS I I FEEDER LOAD 31.55 KVA 88 AMPS I `4c����NG1NEFg`r,0'L LRX PANELBOARD 208/12OV, 3PH, 4W 72336PE SERVES: PHARMACY 100A, M.L.O. L1 U PANELBOARD L2U PANELBOARD LOCATION: PHARMACY 10,000 AIC W 240/12OV, 1PH, 3W 240/12OV, 1PH, 3W PANEL FURNISHED WITH EDC, INSTALLED BY E.C. GROUND BUS SERVES: CRITICAL ISOLATED GROUND EQUIPMENT 100A, M.L.O. SERVES: CRITICAL ISOLATED GROUND EQUIPMENT 100A, M.L.O. ISOLATED GROUND BUS LOCATION: UPS/UPC ROOM 10,OOD AIC LOCATION: EDC2 10,000 AIC KVA FLUSH MOUNTPANEL FURNISHED WITH EDC, INSTALLED BY E.C. EQUIPMENT GROUND BUS PANEL FURNISHED WITH EDC, INSTALLED BY E.C. EQUIPMENT GROUND BUS DESCRIPTION WIRE BRKRPL A B C PL RKR WIRE DESCRIPTION SURFACE MOUNT SURFACE MOUNT 1 EF (PHARMACY) / RECEPT 20 1 0.43 0.24 1 20 CASH REGISTERS (1) 2 KVA A 3 RECEPTACLE 20 1 0.18 0.72 1 20 RECEPTACLES 4 11 DESCRIPTION WIRE RK PL PL RK WIRE DESCRIPTION DESCRIPTION WIRE RKRPL PL RK WIRE DESCRIPTION 5 RECEPTACLES 20 1 0.90 0.36 1 20 RECEPTACLES 6 1 UPS SYSTEM MODULE 15 1 0.25 A 0.36 B 1 20 P.A. / TELEPHONE EQUIP. 2 1 BUSWAY BL2U #10 30 2 1.19 A 1.08 B 1 20 #8 PHARMACY IG RECEPTS (6) 2 7 LASER PRINTER 20 1 0.68 0.18 1 20 RECEPTACLE 8 3 UPS SYSTEM MODULE 20 1 0.25 0.05 1 20 EMS CONTROLLER 4 3 208/120/1 1.00 0.32 1 20 COURTESY CASH WRAP 4 9 LASER PRINTER 20 1 0.68 0.72 1 20 RECEPTACLES (1) 10 5 UPS SYSTEM MODULE 20 1 0.25 0.25 1 20 AP SYSTEM MODULE 6 5 DATA SYSTEM RACK 15 1 0.25 0.18 1 15 DATA SYSTEM RACK 6 11 OVHD ROLLING CLOSURE (2) 20 1 D.96 0.54 1 20 RECEPTACLES (1) 12 7 UPS SYSTEM MODULE 20 1 0.25 0.25 1 20 AP SYSTEM MODULE 8 7 SPARE 15 1 1 20 SPARE 8 13 WH (PHARMACY) (2) #10 25 1 2.00 0.24 1 20 40A BLOOD PRESSURE 14 PANELBOARD 9 UPS SYSTEM MODULE 20 1 0.25 1 20 SPARE 10 9 SPACE SPACE 10 15 PILL COUNTERS 20 1 0.93 1 20 SPARE 16 SCHEDULES 11 UPS SYSTEM MODULE 20 1 0.25 SPACE 12 11 SPACE SPACE 12 17 PHARMACY TOILET LTG 20 1 0.03 0.68 1 20 LASER PRINTER 18 13 UPS SYSTEM MODULE 15 1 0.25 SPACE 14 13 SPACE SPACE 14 19 SPARE 20 1 SPACE 20 15 SPARE 15 1 SPACE 16 15 SPACE SPACE 16 21 SPARE 20 1 SPACE 22 17 SPACE SPACE 18 17 SPACE SPACE 18 23 SPARE 20 1 SPACE 24 19 SPACE SPACE 20 19 SPACE SPACE 20 25 SPARE 20 1 SPACE 26 21 IBM BLADECENTER (3) #10 30 2 1.80 SPACE 22 21 SPACE SPACE 22 27 SPARE 20 1 SPACE 28 23 3.6 KW, 208/1 1.80 SPACE 24 23 SPACE SPACE 24 29 SPARE 20 1 SPACE 30 TOTAL 3.41 2.85 KVA TOTAL 2.70 1.32 KVA TOTAL 3.77 3.23 3.47 KVA Y PER NEC ARTICLE 220 28 24 AMPS PER NEC ARTICLE 220 23 11 AMPS PER NEC ARTICLE 220 31 27 29 AMPS a a TOTAL LOAD 6.26 KVA 30 AMPS TOTAL LOAD 4.02 KVA 19 AMPS TOTAL LOAD 10.46 KVA 29 AMPS _- SHEET: d FEEDER LOADI 6.26 KVA 30 AMPS FEEDER LOAD 4.02 KVA 19 AMPS FEEDER LOADI 10.72 KVA 30 AMPS E4. 2 g , a 0 PANELBOARD NOTES ( ) (1) TERMINATE GROUND ON ISOLATED GROUND BUS. (2) INSTALL LOCKING DEVICE FURNISHED WITH PANELBOARD (LOCK-OFF FOR MAINTENANCE). (3) INSTALL LOCKING DEVICE FURNISHED WITH PANELBOARD (LOCK-ON FOR CRITICAL LOAD). (4) GFI BREAKER FOR PERSONNEL PROTECTION (5 mA). (5) GFI BREAKER FOR EQUIPMENT PROTECTION (30 mA). (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR VOLTAGE DROP. SIZE EQUIPMENT GROUNDING CONDUCTOR PROPORTIONALLY PER NEC. (7) REFER TO ONE-LINE DIAGRAM FOR AVAILABLE FAULT CURRENT FOR INTERRUPTING RATINGS. (8) REFER TO ONE-LINE DIAGRAM FOR WIRE SIZES. N oor (9) FACTORY WIRED TO LOAD. cn o�`2 � pwp 4Z- ZVIS (10) REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. �Qaz�opaww��~Uo lr a rLu Now v_'m�Jwpom (11) THRU CONTACTOR. O s om �xo��Nar li a'n��on wwK (X) DESIGNATES "SMART" BREAKER. z0 aLLz oow N�u�oo w O o mooW 0�o'paazza zlna mawwzw pa W{y rc pwa �ZZpjW�W2W2 W�1p d'w d pOU wN�{yW��FS2Kf/10� NW pFLL�R'OKUd J� � F�ONZ0��6fw/IQ¢KQ� Zy Ogg H �_ adma o WT. M , in. XY e F Z.0 OXO s M z WZ Nwm W 0 W z f 0 U O 0 Lo O O O •-- rl, LIQ n �O O 0 z w b� 00 `o D � CD BL1 A TRACK BUSWAY 208/120W / z LENGTH: 100' 100A RATED 3 ED BUSUS WAYAY �/ �/ Z POWER FEED: CENTER 10,000 AIC oa SERVES: ELECTRONICS TV WALL CASE GROUND o LOCATION: ELECTRONICS DEPARTMENT BUSWAY SYSTEM FURNISHED FOR INSTALLATION BY THE E.C. B100C TRACK BUSWAY KVA DESCRIPTION WIRE BRKRPL PL RK WIRE DESCRIPTION ISSUE BLOCK 1 SPARE 20 1 A 1.44 B C 1 20 #10 11A SEASONAL (6) 2 3 72M TV WALL 20 1 0.96 0.72 1 20 05L GAME DISPLAY 4 BL2A TRACK BUSWAY 208/12OV, 3 PH, 4W 5 72M TV WALL 20 1 0.96 0.72 1 20 05L GAME DISPLAY 6 LENGTH: 150' 100A RATED BUSWAY 7 72M TV WALL 20 1 0.96 1 20 SPARE 8 POWER FEED: CENTER 22,000 AIC 9 72M TV WALL 20 1 0.96 0.96 1 20 72M TV WALL 10 SERVES: FRONT CHECKOUTS CASE GROUND 11 ISPARE 20 Ill 0.96 1 20 72M TV WALL 12 LOCATION: FRONT CHECKOUTS ISOLATED GROUND 13 SPARE 20 1 1 20 SPARE 14 BUSWAY SYSTEM FURNISHED FOR INSTALLATION BY THE E.C. B1 DOG TRACK BUSWAY 15 72M TV WALL 20 1 L 0.96 0.48 1 20 72M TV WALL 16 KVA 17 72M TV WALL 20 1 1 0.96 0.48 11 20 72M TV WALL 18 DESCRIPTION WIRE RKRPL A B PL RKR WIRE DESCRIPTION 19 DL PRINTER 20 1 1.60 1.44 1 20 HP STATION 20 1 FRONT CASH WRAPS 20 1 0.87 0.87 1 20 FRONT CASH WRAPS 2 21 PHOTO LAB RECEPTS 20 1 0.34 1.44 1 20 HP COLOR PRINTER 22 3 FRONT CASH WRAPS 20 1 0.87 0.87 1 20 FRONT CASH WRAPS 4 23 DL PRINTER 20 1 1.60 1.44 1 20 SP UNITS 24 5 FRONT CASH WRAPS 20 1 0.87 1 20 SPARE 6 25 HP WIDE FORMAT PRINTER 20 1 1.44 N/A 26 7 FRONT CASH WRAPS 20 1 1.67 0.30 1 20 CIA CIGARETTES 8 27 PHOTO LAB RECEPTS 20 1 0.54 N/A 28 9 FRONT CASH WRAPS 20 1 1.67 1.36 1 20 FRONT CASH WRAPS 10 29 PHOTO LAB RECEPTS 20 1 0.54 1 IN/A 30 11 jPAY STATION 20 1 0.24 1.35 11 20 1 FRONT CASH WRAPS 12 TOTAL 6.85 1 7.36 7.66 KVA 13 FRONT CASH WRAPS 20 1 1.67 0.90 1 20 1111A SEASONAL / P.V. 14 PER NEC ARTICLE 220 57 61 64 AMPS 15 FRONT CASH WRAPS 20 1 1.67 1.08 1 20 18A SEASONAL 16 17 SPARE 20 1 1 20 SPARE 18 TOTAL LOAD 21.90 IKVA 61 AMPS 19 SELF CHECKOUTS 20 1 0.66 1 20 SPARE 20 FEEDER LOAD 21.90 JKVA 61 AMPS 21 SELF CHECKOUTS (1) 20 1 0.96 0.22 1 20 34A / 34B FITTING ROOMS 22 23 SELF CHECKOUTS (1) 20 1 0.96 1.22 1 20 RTU8 RECEPT 24 CHECKED BY. 25 SPARE 20 1 1 20 SPARE 26 DRAWN BY: TLC 27 SPARE 20 1 1 20 SPARE 28 B L1 B TRACK BUSWAY 208/120V, 3 PH, 4W 29 ICOLUMN RECEPTACLES 20 1 0.72 1.22 1 20 RTU9 RECEPT 30 FILE NAME: E4.3 LENGTH: 100' 100A RATED BUSWAY 31 IPTV 20 1 0.53 0.35 1 20 32A JEWELRY 32 POWER FEED: CENTER 10,000 AIC 33 SPARE 20 1 0.32 1 20 32A JEWELRY C/W (1) 34 PROTO CYCLE: 012712 SERVES: ELECTRONICS POWER DROPS CASE GROUND 35 IDF CABINET 20 11 1.44 1.44 1 20 1 VDF CABINET 36 DDCUMENT DAIS: 041012 LOCATION: ELECTRONICS DEPARTMENT TOTAL 7.82 9.03 9.46 KVA BUSWAY SYSTEM FURNISHED FOR INSTALLATION BY THE E.C. B100C TRACK BUSWAY KVA PER NEC ARTICLE 220 65 75 79 AMPS DESCRIPTION WIRE BRKR PL PL RK WIRE DESCRIPTION TOTAL LOAD 26.31 KVA 73 AMPS 1 SPARE 20 1 0.72 1 20 05G/72G ELECTRONICS 2 FEEDER LOADI 26.39 KVA 73 AMPS 3 05C ELECTRONICS 20 1 0.36 0.36 1 20 87B CONN. CENTER 4 5 05Q VIDEO INTERACT 20 1 0.83 0.72 1 20 72G ELECTRONICS 6 7 72A CONN. CENTER 20 1 0.36 1 20 SPARE 8 9 72J AV ISLANDER 20 1 1.80 1 20 SPARE 10 BL2B TRACK BUSWAY 208/12OV, 3 PH, 4W 11 172J AV ISLANDER 20 Ill 1.80 0.36 1 20 1 105C ELECTRONICS 12 LENGTH: 60' 100A RATED BUSWAY 13 RTU15 &16, AHU3 RECEPTS(6) #8 20 1 1.22 1.22 1 20 #10 RTU12 & 14 RECEPTS (6) 14 POWER FEED: END 10,000 AIC 15 19A FABRIC TABLE 20 1 0.18 0.18 1 20 PRICE VERIFIER 16 SERVES: SALES FLOOR POWER DROPS CASE GROUND 17 05H MEDIA & GAMING P.V. 20 1 0.54 1.44 1 2D #10 IDF CABINET 6) 18 LOCATION: COSMETICS 19 72R LAPTOP ISLANDER 20 1 1.44 1.00 1 20 06H HP KIOSK 20 BUSWAY SYSTEM FURNISHED FOR INSTALLATION BY THE E.C. B100C TRACK BUSWAY 21 72R LAPTOP ISLANDER 20 1 1.44 1-OD 1 20 06H HP KIOSK 22 KVA 23 SPARE 20 1 1 20 SPARE 24 DESCRIPTION WIRE RKRPL A B PL RK WIRE DESCRIPTION 25 068 DPC 20 1 0.60 0.36 1 20 06G PHOTO GONDOLA 26 1 IPTV / PRICE VERIFIERS 20 1 0.62 1.20 1 20 46E RAIL CORNICE 2 27 068 DPC 20 1 0.60 1.80 1 20 06H HP PRINT STATION 28 3 SPARE 20 1 1.20 1 20 46E RAIL CORNICE 4 29 SPARE 1 20 1 1.80 1 20 1 106H HP PRINT STATION 1 30 5 IDF CABINET 20 1 1.44 1.22 1 20 RTU7 & 10 RECEPTS 6 31 SPARE 20 1 1 N/A 32 7 46E RAIL CORNICE 20 1 1.20 1 20 SPARE 8 33 06C FILM DROP 20 1 0.18 N/A 34 9 46E RAIL CORNICE 20 1 1.20 1.44 1 20 08A AQUARIUM WALL 10 35 06B DPC 20 1 0.60 N/A 36 11 SPARE 20 11 0.24 1 20 08A AQUARIUM WALL 12 ITOTAL 6.92 7.90 8.09 KVA 13 46E RAIL CORNICE 20 1 1.20 N/A14 I 15 46E RAIL CORNICE 20 1 1.00 N/A , ` kq�� 723361! 17 46E RAIL CORNICE 20 1 1.20 N/APER NEC ARIICLE 220 58 66 67 AMPSTOTAL LOAD 22.90 KVA 64 AMPSFEEDER LOAD 22.90 KVA 64 AMPS TOTAL 4.22 4.84 4.10 KVAPER NEC ARTICLE 220 35 40 34 AMPS TOTAL LOAD 13.16 KVA 37 AMPS o BL1C TRACK BUSWAY , FEEDER LOAD 15.21 KVA 42 AMPS ZpLp 1�.y��v 208/120V 3 PH, 4W � LENGTH: 100' 100A RATED BUSWAY POWER FEED: END 22,000 AIC BL2U TRACK BUSWAY � ' SERVES: SALES FLOOR POWER DROPS CASE GROUND 208/120V, 1 PH, 3W LOCATION: GM SEASONAL ISOLATED GROUND LENGTH: 150' 40A RATED BUSWAY BUSWAY SYSTEM FURNISHED FOR INSTALLATION BY THE E.C. B100G TRACK BUSWAY POWER FEED: CENTER 5,000 AIC K SERVES: FRONT CHECKOUTS CASE GROUN A D DESCRIPTION WIRE RK PL B PL RK WIRE DESCRIPTION LOCATION: FRONT CHECKOUTS ISOLATED GROUND 1 09A SPORTING C/W 20 1 1.661 20 SPARE 2 BUSWAY SYSTEM FURNISHED FOR INSTALLATION BY THE E.C. B40 TRACK BUSWAY 3 D9A SPORTING C/W 20 1 0.90 0.18 1 20 PRICE VERIFIER 4 DESCRIPTION WIRE BRKR PLA PL RK WIRE DESCRIPTION 5 09A SPORTING C/W 1) 20 1 0.16 1.44 1 20 IDF CABINET 6 AB BUSWAY 7 07A TOYS & P.V. 20 1 1.26 1 20 SPARE 8 1 SPACE 0.51 1 20 FRONT CASH WRAPS 2 SCHEDULES 9 07AB TOYS ACTION ALLEY 20 1 0.18 1 20 SPARE 10 3 FRONT CASH WRAPS 20 1 0.34 SPACE 4 11 SPARE 20 1 0.78 1 20 09C BAIT / 10B AUTO 12 5 SPACE 0.34 1 20 FRONT CASH WRAPS 6 13 12B PAINT MIXING BOOTH 20 1 0.67 1 20 SPARE 14 7 FRONT CASH WRAPS 20 1 0.34 SPACE 8 15 12B PAINT MIXING BOOTH 20 1 1.58 0.80M4.12 1 20 12B PAINT MIXING BOOTH (1) 16 9 SPACE 0.34 1 20 FRONT CASH WRAPS 10 17 12A COLOR CHIP BOARD 20 1 1 20 12B PAINT MIXING BOOTH (1) 18 11 PAY STATION 20 1 0.32 SPACE 12 TOTAL 3.59 3.64KVA TOTAL 1.19 1.00 KVA PER NEC ARTICLE 220 30 30AMPS PER NEC ARTICLE 220 10 8 AMPS TOTAL LOAD 11.35 KVA AMPS TOTALLOAD 2.19 KVA 11 AMPS FEEDER LOAD 11.40 KVA AMPS FEEDER LOAD 2.19 KVA 11 AMPS i. SHEET: E 4. 3 Q O GENERAL REFRIGERATION CHA1 PANELBOARDNOTES 208/120V, 3PH, 4W 1. PROVIDE ALL CONDUIT AND WIRE AS INDICATED ON DRAWING. NEATLY BUNDLE CIRCUITS AND SERVES: REFRIGERATED CASE FANS, LIGHTS, RECEPTACLES & A/S HEATERS 100A, M.L.O. CLEARLY TAG AND LABEL EACH CIRCUIT WITH LOCATION: HYBRID HOUSE DTA 10,000 AIC BRANCH CASE ELECTRIC DEFROST FEEDER SCHEDULE BRANCH CIRCUIT DESIGNATION AND PANEL PROVIDED WITH HYBRID HOUSE GROUND BUS REFRIGERATION SYSTEM NUMBER FOR TERMINATION BY REFRIGERATION CONTRACTOR. PANEL PROVIDED WITH 10DA FEEDER MINIMUM SURFACE MO NTI NO. CONDUIT NUMBER AND EQ. GROUND 2. COORDINATE ALL WORK WITH REFRIGERATION VA SIZE SIZE OF WIRE NOTES CONTRACTOR PRIOR TO INSTALLATION. DESCRIPTION WIRE BRKRPL PL RKR WIRE DESCRIPTION CONDUCTORS A B C 3. KEEP PENETRATIONS THROUGH COOLER AND 1 A01 CASE FANS 20 1 0.08 1.40 1 20 #8 A07 CASE A/S HTRS (6) 2 ❑ 1/2 (2) #12 (1) #12 E.C. SHALL PROVIDE CONDUIT AND WIRE FOR REFRIGERATED FREEZER BOXES TO A MINIMUM. ROUTE ALL 3 A01 CASE LIGHTS 20 1 1 0.06 1.12 1 20 2 1 2" CASE ELECTRIC DEFROST TO DESIGNATED PANEL IN #10 A07 CASE A/S HTRS (6) 4 ❑ / (2) #8 (1) #10 CONDUITS SERVING FREEZERS AND COOLERS ON COMPRESSOR RACK. FINAL TERMINATIONS AT CASE AND AT INSIDE OF BOX, 5 A01 CASE A/S HTRS 20 1 0.28 0.52 1 20 A07 CASE LIGHTS 6 ❑ 1/2" (3) #8 (1) #8 COMPRESSOR RACK BY R.C. REF DETAILS 3-RE1.1 AND 7 A02 CASE FANS 20 1 0.69 1.10 1 1 20 #10 A07 CASE FANS (6) 84-RE1.1. 4. UNDERSLAB CIRCUITS SHALL NOT BE ROUTED 9 A02 CASE LIGHTS 20 1 0.38 0.46 1 20 A08 CASE LIGHTS 10 ® 1/2 (3) #10 (1) #10 UNDER WALK-IN FREEZERS AND SHALL BE 11 A02 CASE A/S HTRS (6) #8 20 1 1 1.81 1 0.93 1 20 #10 A08 CASE FANS (6) 12 3/4" (3) #8 (1) #10 ROUTED ABOVE REFRIGERANT LINES WHERE THEY CROSS. 13 A03 CASE FANS 20 1 0.62 1.40 1 20 #8 A08 CASE A/S HTRS (6) 14 © 3/4" (3) #6 (1) #8 5. ON GROUPS OF THREE OR MORE REFRIGERATED LLJ 15 A03 CASE A/S HTRS (6) #8 20 1 1.67 0.84 1 20 #10 A08 CASE A/S HTRS (6) 16 CASES WITH ELECTRIC DEFROST, REFRIGERATION opt a9zwo �za 17 A03 CASE LIGHTS 20 1 0.35 1.12 1 20 #10 A09 CASE A/S HTRS (6) 18 CONTRACTOR SHALL CONNECT CASES TO w oFF_2aaao�z �o 19 A04 CASE FANS 20 1 0.62 1.40 1 20 #8 A09 CASE A/S HTRS (6) 20 HEATER A THREE-PHASE EATER CIRCUIT. N a¢ Nowa"< vi 0 21 A04 CASE A/S HTRS (6) #8 20 1 7.67 1.10 1 20 #10 A09 CASE FANS (6) 22 WALK- IN UNIT COOLER FEEDER SCHEDULE o Q}=N� 23 A04 CASE LIGHTS 20 1 0.35 0.52 1 20 A09 CASE LIGHTS 24 ELECTRIC PHASES AS EVENLY AS POSSIBLE (REF CASE ,nUwa�V opraw w� 25 A05 CASE LIGHTS 20 1 0.35 1 2D SPARE 26 CONDUIT COIL FANS EQ. GROUND DEFROST WIRING DETAIL). 3�<�E�Nww�oo�o NO. DEFROST NOTES SIZE (CF) WIRE Sao ow101z,a Qzoa 27 A05 CASE FANS 20 1 0.69 1 20 SPARE 28 (ED) 6. ROUTE REFRIGERATED CASE AND COIL FAN, z nd Ja w1z 29 A05 CASE A/S HTRS (6) #8 20 1 1.68 1 20 SPARE 30 7 LIGHTS, ANTI-SWEAT AND DEFROST BRANCH J <`k a�zFwa n��ow� ❑ 3/4„ (2) #12 (2) #8 (1) #8 �zzoow www F.+o ¢w CIRCUITS TO WIREWAYS PROVIDED AT 000 Dm-W=bwomv o� 31 A06 CASE LIGHTS 20 1 0.46-T-0.18 1 20 A02 CASE RECEPTACLE 32 g 3 4' 2 12 2 6 1 6 REFRIGERATION EQUIPMENT. PROVIDE AN N�NOLL� �o�o a�� ( ) #10 20 1 0.93 0.18 1 20 A03 CASE RECEPTACLE 34 ( ) aozw¢ww�o 33 A06 CASE FANS 6 / ( ) # ( ) # O # E.C. SHALL PROVIDE CONDUIT AND WIRE FOR EVAP. COIL FAN CF AND ADDITIONAL 6 FEET OF CONDUCTOR AT 35 A06 CASE A/S HTRS (6) #8 20 1 11.40 0.18 1 20 A04 CASE RECEPTACLE 36 0 1" (2) #12 (2) #4 (1) #8 ELECTRIC DEFROST (ED) TO DESIGNATED PANEL IN COMPRESSOR RACK. FINAL TERMINATIONS AT COIL AND AT COMPRESSOR RACK BY R.C. REF REFRIGERATION EQUIPMENT TO ALLOW 37 A06 CASE A/S HTRS (6) #10 20 1 0.84 0.18 1 20 A05 CASE RECEPTACLE 38 10 1/2" (2) #12 (3) #12 (1) #12 DETAIL 2-RE1-1. ADEQUATE LENGTH FOR TERMINATION. FINAL Z)NI 39 SPARE 20 1 1 0.18 1 20 A06 CASE RECEPTACLE 40TERMINATION AT REFRIGERATED CASES BY 41 SPARE 20 1 0.18 1 20 A08 CASE RECEPTACLE 42 11 3/4" (2) #12 (3) #10 (1) #10 REFRIGERATION CONTRACTOR. H� o TOTAL 9.30 9.28 9.32 KVA 12 '" c2> #'° (3) #8 (') #8 REFRIGERATED CASE WW LLI PER NEC ARTICLE 220 78 77 78 AMPS WIRING NOTES o zc� m TOTAL LOAD 27.90 KVA 77 AMPS FEEDER LOAD 29.04 KVA 81 AMPS _ PE WZ jxo d z r 1. E.C. SHALL PROVIDE CONDUIT AND WIRE FOR a =Lu REFRIGERATED CASE FANS, LIGHTS AND CHA2 PANELBOARD ANTI-SWEAT SWEAT HEATERS TO , UNLESS AT z W REFRIGERATION EQUIPMENT, UNLESS NOTED p OTHERWISE. WIRE SIZE AS INDICATED IN L 208/120V, 3PH, 4W SCHEDULE. FINAL TERMINATIONS AT CASE AND SERVES: REFRIGERATED CASE FANS, LIGHTS, RECEPTACLES & A/S HEATERS 100A, M.L.O. O O AT REFRIGERATION EQUIPMENT BY R.C. REF LOCATION: HYBRID HOUSE DTA 10,000 AIC CASE CONNECTION WIRING DETAIL. PANEL PROVIDED WITH HYBRID HOUSE GROUND BUS 2. REFRIGERATED CASE WIRING COMPARTMENT REPRESENTED ON DRAWING BY RECTANGULAR PANEL PROVIDED WITH 50A FEEDER MINIMUM SURFACE MOUNT �___ _ ___;__________ __ ________ _______ REF 1-REI.( BOX. OD Z DESCRIPTION WIRE BRKRPL KVA PL RK WIRE DESCRIPTION CD 3. CIRCUITS FOR REFRIGERATED CASES SERVED BY �1 AB C UNDERSLAB REFRIGERATION PIPING ARE TO BE v v 1 A10 CASE FANS 20 1 0.87 0.18 1 20 A10 CASE RECEPTACLE 2 I CHAT-38 ROUTED UNDERSLAB. REFER TO CASE 3 A10 CASE A/S HTRS (6) #8 20 1 1.67 0.18 1 20 A11 CASE RECEPTACLE 4 CONNECTION WIRING DETAIL. CHAT-7,9,11 4. ALL UNDERSLAB CONDUITS SHALL BE 3 4 MIN. �J� 1���� 5 A10 CASE LIGHTS 20 1 0.44 0-18 1 20 A17 CASE RECEPTACLE 6 / L 7 A10 CASE A/S HTRS 20 1 0.42 0.18 1 20 A17 CASE RECEPTACLE 8 I CHAT-25,27,29 =. A02 5. CIRCUITS FOR REFRIGERATED CASES SERVED BY of 9 A11 CASE LIGHTS 20 1 0.38 0.18 1 20 A19 CASE RECEPTACLE 10 I - ------- -- ------.- -- ----- -- -- ---- -- OVERHEAD REFRIGERATION PIPING ARE TO BE � Gw ROUTED DOWN FROM STRUCTURE AT THE SAME 11 A11 CASE A/S HTRS (6) #6 20 1 1.82 0.18 1 20 A19 CASE RECEPTACLE 12 iLIT ! HA1-32 LOCATION AS THE REFRIGERATION PIPING AND vV O 13 A11 CASE FANS (6) #10 20 1 0.77 SPACE 14 - = - _- -- _ EXTENDED TO THE FIRST CASE IN EACH V z 15 A16 FANS & A/S HTRS 20 1 0.91 SPACE 16 SYSTEM BY THE E.C. WIRE AND CONDUIT FOR 17 A17 FANS & A/S HTRS 20 1 0.42 SPACE 18 A05 _ - A02 ❑5 SLAVE WIRING BETWEEN CASES SHALL BELi 19 A18 FANS & A/S HTRS 20 1 0.65 SPACE 20 i CH AI-40 CHAT-13,15,17 PROVIDED BY THE R.C. 21 A19 FANS & A/S HTRS 20 1 0.42 SPACE 22 A06 A06 A06 _ A03. O 23 SPARE 20 1 SPACE 24 25 SPARE 20 1 SPACE 26 PANELBOARD NOTES 27 SPARE 20 1 SPACE 28 29 SPARE 20 1 SPACE 30 v r4 31 SPARE 20 1 SPACE 32 I -, ` _ _ _ -- (1) TERMINATE GROUND ON ISOLATED GROUND BUS. HAI-34 ERMINA 33 SPARE 20 1 SPACE 34 i �-- (2) INSTALL LOCKING DEVICE FURNISHED WITH z 35 Al2 EMS CONTROLLER 20 1 0.01 SPACE 36 6 - - - -- PANELBOARD (LOCK-OFF FOR MAINTENANCE). 0.1 REF 1-REI 1 _ CHA1-31;33,35,37 A07 A07 `A03 -❑ o 37 A13 EMS CONTROLLER 20 1 0.01 SPACE 38 ------` ---- ------ --- -- CHAT-42 CHAT-19,21,23 (3) INSTALL LOCKING DEVICE FURNISHED WITH qw 39 A14 EMS CONTROLLER 20 1 0.01 SPACE 40 _ A08 A08 A04 PANELBOARD (LOCK-ON FOR CRITICAL LOAD). 41 A15 EMS CONTROLLER 20 1 o-1 SPACE 42 A08 "- - A04 (4) GFI BREAKER FOR PERSONNEL PROTECTION TOTAL 3.08 3.75 3.06 KVA - = - -- - - - - -- ---- - - - 5 mA). ISSUE BLOCK REFRIGERATED -- O PER NEC ARTICLE 220 26 31 25 AMPS CASE ELECTRICAL '`, (5) GFI BREAKER FOR EQUIPMENT PROTECTION CONNECTION © (30 mA). TOTAL LOAD 9.89 KVA 27 AMPS ; POINT, TYP CHAT-36 "' (6) CONDUCTOR SIZE HAS BEEN INCREASED FOR FEEDER LOAD 10.31 KVA 29 AMPS =1 - - - - - VOLTAGE DROP. SIZE EQUIPMENT GROUNDING CHAT-,Q i2,14,i6 © �� Z%f * fes;- CONDUCTOR PROPORTIONALLY PER NEC. f o l 16 - ^- O !/ f r A09 A04 (7) REFER TO ONE-LINE DIAGRAM FOR AVAILABLE CHB PANELBOARD r;Hn2_A & A11 m " CHA2 911.13 CHA2-1,3,5,7 FAULT CURRENT FOR INTERRUPTING RATINGS. H, I A10 (8) REFER TO ONE-LINE DIAGRAM FOR WIRE SIZES. 208/120V, 3PH, 4W SERVES REFRIGERATED CASE FANS, LIGHTS, RECEPTACLES & A/S HEATERS 100A, M.L.O. A11 _ - , _ - (g) FACTORY WIRED TO LOAD. LOCATION: HYBRID HOUSE MTB 10,000 AIC PANEL PROVIDED WITH HYBRID HOUSE GROUND BUS CHC-6,8 _ CHC-14,_16 (10) REFER TO SITE LIGHTING PLAN FOR WIRE SIZES. C _ ._ __- _ . _ .._ - _.- _ ______ __ _. _- . __.__ _. _ .__.. . _--- -- -� _. _ _-_- _. _„___ _. _ . . _. -----_ _ - �_. . _ _ _ _- - _ -- - -- -- -_ _ ___. _ _- - - --- -- (11) THRU CONTACTOR. ROUTE CASE LIGHTS VIA LIGHTING CONTACTOR PROVIDED WITH HYBRID HOUSE - - - ---- _ -- --- - �-' PANEL PROVIDED WITH 60A FEEDER MINIMUM SURFACE MOUNT i CHA2-2 (X) DESIGNATES "SMART" BREAKER. VA BAKERY DESCRIPTION WIRE RKRPL A B C PL RK WIRE DESCRIPTION - - " - --- - -- " �' - SALES I 1 801 CASE FANS 20 1 0.24 0.18 1 20 B06 CASE RECEPTACLE 2 C12 C14 i KEYNOTES 3 B01 CASE LIGHTS (6,11) #10 20 1 D. 0.18 1 20 B06 CASE RECEPTACLE 4 16.710 i 16.708 5 B02 CASE LIGHTS (6,11) #8 20 1 1.26 0.18 1 20 807 CASE RECEPTACLE 6 CHC-38 16YP6 I 16.711 C14 TYP 7 B02 CASE FANS 20 1 0.36 0.18 1 20 B07 CASE RECEPTACLE 8 CHC-10,124 i TYP 16.708 PROVIDE WIRING AND FINAL CONNECTIONS CHC-22,24 CHC-18,20 9 B05 CASE FAN 20 1 0.31 1 20 SPARE 10 TO RECEPTACLE. RECEPTACLE FURNISHED 1111305 CASE LIGHTS (11) 20 1 0.50 1 20 SPARE 12 16.717 __ - - j--- WITH REFRIGERATED CASE. CHECKED BY: 13 B06 FANS & A/S HTRS (6) #10 20 1 1.00 SPACE 14 _ - - -_ +20" �� 16.710 ENERGY MANAGEMENT CONDUITS: PROVIDE _ DRAWN BY: TLC 15 B07 FANS & A/S HTRS 20 1 0.39 SPACE 16 J J J v 1" (UNLESS NOTED OTHERWISE) PVC 17 SPARE 20 1 SPACE 18 ----- CONDUIT (WITH PULL WIRE) UNDER FLOOR FILE NAME: RE1 19 SPARE 20 1 SPACE 20 SALAD = SLAB FOR LOW VOLTAGE CABLES. STUB 21 SPARE 20 1 SPACE 22 _ PREP NOTE: !PROVIDE 208V SUPPLY SOLENOID ' CONDUIT THROUGH PIT SIDEWALLS A PROTO CYCLE: 012712 ` VALVE !WIRING ( (2) #12 W/(1) #12 GND); k ss MINIMUM OF 2". WHERE UNDERSLAB 23 SPARE 20 1 SPACE 24 _ - CONDUIT IS SHOWN CONTINUING UP IN WALL DOCUMENT DATE: 041012 G L` C15 TO EACH REFRIGERATED CASE AND COIL.; ADJACENT TO PIT, PROVIDE 1" CONDUIT 25 SPACE SPACE 26 - # ':CHC 26,_- ; TERMINATION OF 208V WIRING AT C13 (WITH PULL WIRE) ROUTED FROM 6" ABOVE 27 SPACE SPACE 28 I r i CASE/COIL AND AT TERMINATION STRIP IN BOTTOM OF BAR JOIST IN SALES FLOOR 29 SPACE SPACE 30 s I COMPRESSOR RACK BY R.C. SOLENOID 31 SPACE SPACE 32 a ACCESSIBLE CEILING SPACE AND CONNECT u I I s, �. , WIRING FOR CASES AND COILS NOT SHOWN TO PVC CONDUIT STUBBED THROUGH PIT 33 SPACE SPACE 34 j��l, r' ON PLANS FOR CLARITY. COORDINATE I 35 SPACE SPACE 36 DRY iLl' I ' xl; 16.708 EXACt LOCATION OF SOLENOID VALVES WALL. 37 SPARE 20 1 SPACE 38 -PR.ODUC�- J ` TYP C16 WITH R.C. PRIOR TO INSTALLATION 16.711 POINT OF TRANSITION FROM EMT TO FLEX. 39 BD3 EMS CONTROLLER 20 1 0.01 SPACE 40 PREP " ` ' CF ' , `- ! \ \ � PROVIDE CONDUIT AND BRANCH CIRCUITS e FOR REFRIGERATED CASE FANS, LIGHTS, 41 B04 EMS CONTROLLER 20 1 0.01 SPACE 42 ANTI-SWEAT HEATERS, AND ELECTRICAL TOTAL 1.96 1.73 1.95 KVA 1' DELI CHC-40,4 24 DEFROST (IF REQUIRED). TERMINATION TO PER NEC ARTICLE 220 16 14 16 AMPS COOLER r( r '`,, ,i I �" REFRIGERATED CASE ELECTRICAL CONNECTION r' GROCERY POINT BY R.C. REFER TO CASE CONNECTION CHC-28', t r l ` r CHC 34,36 WIRING DETAIL. TOTAL LOAD 5.64 KVA 16 AMPS \ -'! SALES FEEDER LOAD 6.38 KVA 18 AMPS 16Y7P23r G >> '. s 16.716 SLAVE WIRING BETWEEN REFRIGERATED CASES IN WIREWAY PROVIDED BY REFRIGERATION CONTRACTOR. B ______ - ® ®� j mss; _ ` _ \z _ __ _ _-. _, _ _� _ _ _ �. e _ _ _ ® 16.717 ENERGY MANAGEMENT CONDUITS: PROVIDE CHC PANELBOARD \i RECESSED JUNCTION BOX WITH COVER DELI PREP 16.717 - I PLATE FOR DIRECT CONDUIT CONNECTION AT 208/120V, 3PH, 4W -: ! SERVICE' Y� r CHC-303 f' +80" (UNLESS NOTED OTHERWISE). PROVIDE SERVES: REFRIGERATED CASE FANS, LIGHTS & A/S HEATERS 100A, M.L.O. 3 4" CONDUIT WITH PULL WIRE FOR LOW DELI \ C19 I / ( ) LOCATION: HYBRID HOUSE MTC 10,000 AIC ------ VOLTAGE CABLES FROM JUNCTION BOX TO /�,//, _ PANEL PROVIDED WITH HYBRID HOUSE GROUND BUS �, - DELI POULTRY ' '� i J � I 6" ABOVE BOTTOM OF BAR JOIST IN SALES ROUTE CASE LIGHTS VIA LIGHTING CONTACTOR PROVIDED WITH HYBRID HOUSE J UTILITY COOLER `�6 510 ------= FLOOR ACCESSIBLE CEILING SPACE. PANEL PROVIDED WITH 60A FEEDER MINIMUM SURFACE MOUNT C18 " 1 16.723 REFRIGERATION ENERGY MANAGEMENT ponnllr� CHA2 35 B03 i ti r DESCRIPTION WIRE BRKRPL KVA PL RK WIRE DESCRIPTION COOLERSYSTEM ��._ CHB-39 CONTRACTOR ALL 120VAC (FINAL tm� A B C 16.717 ., ROTISSERIE - I / �5 ��1GfRE�c `r/O 1 C01 CASE FANS 20 1 0.17 0.22 1 20 C11 CASE FANS 2 N „ �- w- a- TERMINATIONS AT ENCLOSURE BY R.C. 0 9 y 3 C01 CASE LIGHTS (11) 20 1 0.50 0.55 1 20 #10 C11 CASE LIGHTS (6,11) 4 PREP 1! - I VERIFY EXACT LOCATION OF ENCLOSURE Q 72335PE r 5 CO2 CASE FANS 20 1 0.22 D.17 1 20 C12 CASE FANS 6 j ' F _ I r ^\ 1� WITH EMS CONTRACTOR. i 7 CO2 CASE LIGHTS (11) 20 1 0.45 0.34 1 20 C12 CASE LIGHTS (11) 8 I ;�; i//%� r I 10 ------------------------- 9 _______________________________ 2 ry �. Al2 j ORE N oO 9 CO3 CASE FANS 20 1 0.17 0.36 1 20 C13 CASE FANS 10 '�' J ! DELI ` 11 CO3 CASE LIGHTS (11) 20 1 0.34 0.79 1 20 #10 C13 CASE LIGHTS (6,11) 12 �`! i FREEZER CF if F3 \\ v ' ALL CONDUIT DROPS NEAR GROCERY FASCIA SHALL DROP 13 C04 CASE FANS 20 1 0.22 0.22 1 20 C14 CASE FANS 14 , 1 c A MINIMUM OF 2'-0" BEHIND 15 C04 CASE LIGHTS (11) 20 1 0.67 0.45 1 20 C14 CASE LIGHTS (11) 16 it -__ EQ ` � k.° ,r."` :. ; ' .r ( ( _< w -- - ._ -_ T , I FASCIA TO MINIMIZE VISIBILITY 17 CO5 COIL FANS 20 1 0.43 0.11 1 20 C15 CASE FANS 18 -- - _ - IXPIRES:O6/3p2pf$ 19 C06 COIL FANS 20 1 1.01 0.34 1 2D C15 CASE LIGHTS (11) 20 21 C06 COIL FANS 20 1 1.01 0.04 1 20 C16 CASE FANS 22 - .- 23 C07 COIL FANS 20 1 1.01 0.23 1 20 C16 CASE LIGHTS 11 24 ( ) ' it 25 C07 COIL FANS 20 1 1.01 0.54 1 20 #10 C17 COIL FANS (6) 26 ----------- 27 DIARY COOLER DR LTS (11) 20 1 0.64 0.43 1 20 #10 C18 COIL FANS (6) 28 - 29 DAIRY COOLER DR HTRS (6) 20 1 1.21 0.20 1 20 C19 CASE FANS 30 ,, i REFRIG 31 C08 CASE FANS 20 1 0.25 0.59 1 20 #10 C19 CASE LIGHTS (6,11) 32 _ _ I _ _L - JL_ _- _ I, u J _ 33 C08 CASE LIGHTS (11) 20 1 0.76 0.19 1 20 C20 CASE FANS 34 J ELECTRICAL 35 C09 CASE FANS 20 1 0.28 0.50 1 20 #10 C20 CASE LIGHTS (6,11) 36 „ - 37 C09 CASE LIGHTS (6,11) #10 20 1 0.84 0.36 1 20 C15 CASE RECEPTACLES 38 ! EDC4 :I - • J PLAN `; " - - ' - 39 C10 COIL FANS 20 1 0.32 0.18 20 C20 CASE RECEPTACLE 40 ) j 41 SPARE 20 1 0.18 1 20 C20 CASE RECEPTACLE 42 FRONT REFRIGERATION ELECTRICAL PLAN TOTAL 6.56 6.28 5.66 KVA PER NEC ARTICLE 220 55 52 47 AMPS TOTAL LOAD 18.50 KVA 51 AMPS a FEEDER LOAD 20.75 KVA 58 AMPS a d SHEET: Q RE1 0 I KEYNOTES 16.708 PROVIDE WIRING AND FINAL CONNECTIONS TO RECEPTACLE. RECEPTACLE FURNISHED WITH REFRIGERATED CASE. 16.710 ENERGY MANAGEMENT CONDUITS: PROVIDE 1 2 3 3.4 4 1" (UNLESS NOTED OTHERWISE) PVC CONDUIT (WITH PULL WIRE) UNDER FLOOR SLAB FOR LOW VOLTAGE CABLES. STUB CONDUIT THROUGH PIT SIDEWALLS A MINIMUM OF 2". WHERE UNDERSLAB P 0 3 CONDUIT IS SHOWN CONTINUING UP IN WALL ,I e 1 ,r r n ti d k t .. 1f ...w ....._�..,,.,:.a. _w w_ .. .• _ ._....-.w......, .M .._.__._. " ,, .. .N, _...W. _..,,...,.9....999,.._._,.. W. -w ,, w, ,, W ,W_.,,._ . _M.. ,_., ,,..w... .. .. w ». w. _. _._ W W. .,._, ., n a ADJACENT TO PIT, PROVIDE 1 CONDUIT TYPICAL REFRIGERATED CASE SYSTEM (WITH PULL WIRE) ROUTED FROM 6 ABOVE ___ - .-_,•._ �.-. __.. _�.-_, -_ .__ .. _..__.. ,—______ �._ a., _ �._....____ ._._ _ . N 3 BOTTOM OF BAR JOIST IN SALES FLOOR . _ .. _ __ .. ., .,_. .. _. .._. ,. _ .._ _._. ..... ,. n_ ..�..... .,.�._.� �. .�....�.,. _..._.......-,_...__...�w_.: .,�_..._�._... .w. �.._.._...,_ ,...�.�......... ...,. ._�...�_.. .._ .....,._.M...... ... �.._.�...,..__ .... ._.,....�.:.� . ...,.__...�._.._.�,_.._....._. �..M._,"...... _...__,...w,..:,. .�: .......µ_....., ..._ ..�._..._.K_,�:.. ,� .�t~�.. .._ _._........-�_ ....._�...���_-,.ww_.N ___._......4_.__ � ..,..._..�.._....�. .......-.,__.,.w...._.._._.�. _.__..�..�. ....,M.�.__,. ,.. . ..�... �. _:�.�.. .. n..._.._.., ,..�._, w . .._..._,.. _. ..._ .� .�:. q ._:,..—... ....w..,.__, ACCESSIBLE CEILING SPACE AND CONNECT H 5 O N CTH5 DOOR CASE 5 DOOR CASE 4 DOOR CASE TO PVC CONDUIT STUBBED THROUGH PIT WALL. t , I TYP 1 3 1 t i i .„.,,. ......_._.�..,.-.�....•"�<° ""Y r•:.«„ Y',r'f d kd F— I 12.6 A I 12.6 A r 9.9 A 6 a ; 16.723 ~; �, :� I 16.711 POINT OF TRANSITION FROM EMT TO FLEX. w o � oo� x __� PROVIDE CONDUIT AND BRANCH CIRCUITS cn � � ao '�-z¢ +�, �° P I "1 o H r z w r� � t� € i __ _ ._. _ .__ .._ _.� _� $ � I FOR REFRIGERATED CASE FANS, LIGHTS, t,,., or iEiEa o�z �z AND ELECTRICAL � o mow, ot:-'���'Q�0 _ . — _.� —zflmANTI SWEAT HEATERS, ¢a o a� �a TERMINATIONW as •—•..-d .. . ... ..._.v.._. _... w. I T _ �t iw �,,, ,� � ,.......—.,..,�.- � IF REQU RED 0 ,. AO !/f4m:7h.R l4:NMC1%.Jdtir)YCa.LY,WRM\iNYlb✓Y'1v��hyfYlWk NG11Y21i1V:iMYSC1YA 1 "RA➢Ei�IS0Lk4V1'9NNiWLL MUV.IIM1!W^'�""11 '4'Nw l^. 69'Lfi V.Wh 1 .K44A't4'AUOWw.Y iJW':XYWUI181Y91,MU9hi5pYtWW y A{ t I� J �j `� :� O �/�V!\w I— (]^.�' w•rsvw..rM.Nnwmn.erW.ar-inrrt'nr.mn ^^^- tea.,.+..i•..ne...-. V u G. Ij ' � _ �� ° REFRIGERATED CASE ELECTRICAL CONNECTION �- a N 5, W W 0., o>- ! 11 I F ►,a I E 3 o\ ..�- �wz�aa ` ;1 I '`, ....., r` . FTCF ., POINT BY R.C. REFER TO CASE CONNECTION z ¢�_zc`�oW 0Z3o. NO� wCF Ali �V¢ www w�Qo�oBoWIRING DETAIL. Wazo ��Qzzz Co C07 C06 C07 C06 I z V)a o J� z o a o► � z � �;.. { �� CF CF CFi#'> Q m° 4;�ao �PROVIDE 208/30 HOME RUN TO PRE-WIRED PANEL `� � ���� �__. _ .__ _�__�_.___._��__._,._._ __ _� _�,� .____ __ _ .._,1 � � t � 16.714 COOLER DOORS: PROVIDE WEATHERPROOF __, Q¢�Qa►-ww �vzN� j! ti I li I ! JUNCTION BOX FOR DOOR FRAME POWER. ozzc3DLu wwv�o �w IN COMPRESSOR RACK. FINAL CONNECTION AT l e� ,''"` t ,.�_.... A15 �,t I ; ' � '", :3 f v ED o0 w��ma o W o € E.r!..re..� I a p � ' ; t I( ) � t i � i;x v L �5=0.U7 EACH END BY REC ,�'`� 3 _ _,� _ _ _ �_ , e, >>' c 'c ;€ FINAL CONNECTION BY R.C. Nw �o�Waoava� ' 3a yaw t ICE CREAM -.. �..w�"'_. #-.,_ .. .. �c o z w w w o ?, r-- ( CHC-23 CHC-19 CHC-25 CHC-21 c o �„�...�..... ..._.._.�.�..,..,:.._.___.._,.........._,.�...,,>w....,...�.—:�..�. �..�,.�.�•�ti,::�:.:.��':_,.-x-.:.:J i k � � � �w¢cn¢�a¢F-• NOTE: ' �� f FREEZER " _ " � __��_� _��._ �� � ��_ �t DAIRY i I 16.716 SLAVE WIRING BETWEEN REFRIGERATED A14 CF C05 _ C05 r. I COOLER I CASES IN WIREWAY PROVIDED BY ON SYSTEMS WITH UNEQUAL LOADS, REC (REFRIGERATION ELECTRICAL GROCERY J 12 �- REFRIGERATION CONTRACTOR. ` CONTRACTOR SHALL ARRANGE CONNECTIONS FOR MAXIMUM BALANCE I ❑ '' `� �'' '� Z I 11 FREEZER � ED ;1� ,�''• � a �» � v � �I I 16.717 ENERGY MANAGEMENT CONDUITS: PROVIDE �. .•�.� � o E � RECESSED JUNCTION BOX WITH COVER C TYP V! CF J J PLATE FOR DIRECT CONDUIT CONNECTION AT W E. CALCULATION OF 30 UNBALANCED LOAD I —���� — - _ ,�— —— 16.714 � �;� „ 0 - � � a. ! I , , ,.. . ... � 1 ,. ;. S NOTED -OTHERWISE). PROVIDE W�-.- + N „..,........_..«..»._.._.:--._................_.._......._.....--.-......r-....y.:»_-:........�._......_...,.....,_,......,..,«,,..-.:.,..... ..-.. , 1 , .: 1 1 1 I 1 1 I ,. I .1 ' 1 f. 1 .�I .I ; ( I 1 3 3 I ...3 f: ,. 3 �l • � . � 80 (UNLESS E .,,..».,,....„.....,..................».,,.»....... _ .........«,...,...,..❑99.9..9„. ,.«,......,,w.,.,„_. :.,...,�:..«� a.....,_......,,.,. �...»...,.._ ......,.........•...�...... .,,.,....„_."...,«._,,..........,,....., a...«., ......,,:..........:,.,..........� '�. et ,mmclnmr+mhun' rg,x?uj. M°4� �' :wiumuw' xnwrina r.+h.,awm,mib,m ' itee�,ebac.� w_ .,..S,_,..,,�.+..,... .... AO LOAD 12.6A + 9.9A x .866 = 19.5A 3 G3/4- ie o M ( ) i l II d CONDUIT WITH PULL WIRE FOR LOW e 9 9f�..,..,.rr.w. F' ;; r. t I I i I S I 1 i i jj F I i — _ a� 4' y 3• �. � r I l i r i { i i i a ! � i I I 3 E N 11• BO LOAD 12.6 A + 12.6 A x .866 21.8 A HIGH LEG r X31 � � h � , � �_ � , I _, I �, IVOLTAGEW a . � ',� �s �� .� :�• >� A F OM J CTION B X TO ( � CABLES R UN 0 C ) C CO LOAD = 12.6 A + 9.9 A x .866 = 19.5 Ar= �. ____ ' �w_ ____ _. _, � __ __� �___ _ ;_� -_��, ..,. .� zo w . �_ ' -.:—w _.�_ �... � �._.�� W�,. 4 ,- -, a a► C ) ii I ,'-- > , � �: .tea. , . �„ �, a_ I 6 ABOVE BOTTOM OF BAR JOIST IN SALES z � ,o s M F.H _._ _�_ __ __ ��_ 6 g ; CHB-9,11 � "`*�"� �`` `` �� _�. ", ,�� ,�,!' '� ,, 13` r , � ,� ' r ,�; �`a,F `'°,,, `*,,�' ,� FLOOR ACCESSIBLE CEILING SPACE. Q_ Wi si■ �C14� ti I .. M 1 B 0 5 .....,,,:""" ,,.....r"'" N,r''` ...,.,.,,+'+ ...w'^'''" ...«..<„", ...,..✓' ...,,✓"� +"''". ....-«'y .......' .,« ""� .,«...+ ...a.„� ..,.»✓"�i .•_ ,...,' '� ✓' '"t --e -11......•r.s� < d$ ` C08 KJ CHC-27,29 I 16.723 REFRIGERATION ENERGY MANAGEMENT = � I SYSTEM CONTROLLER PROVIDED BY EMS 5 �', I m "� n CONTRACTOR. ALL 120VAC FINAL o CASE DEFROST WIRING - - � . - r�� }, _ /�_ _ ��°��. yt��w�1~�1��«ti � ~°°�� ����~~~ tea..r �` � � TERMINATIONS AT ENCLOSURE BY R.C. v _i" .__... _ �. c� t !..,.._.._.»......_:._._�..-".n..,..r ii;:ill:w�T3l.I.�•. ,!"�G"'1._.._ k; m k . NTS 05.29.09 ER03 C01 3 VERIFY EXACT LOCATION OF ENCLOSURE WITH EMS CONTRACTOR. I � I CHA2-39 I I� '� I �++r-❑1 � �..-. ..-. �.._. �...,:�- - �W�� �.._� �.,,,�.. CHA2-41 � � �� 1 1 � � I T 16.717 — REFRIGERATED CASE TOn„.__g. ...._ : _..� _-_.____ _ � m __�___._ _ ___.. CHC-1,3 — � J I GOS 607a -- CHC-13,15 Gj WIRING NOTES _ _ e R 6 romrx4:.::GY n n I IE.C. HA PROVIDE CONDUIT AND WIRE FOR E C SHALL RO DE U REFRIGERATED CASE FANS, LIGHTS AND 3 r. . t' ` 16.710 i ¢ CO3 - J CO2 C0� I CHC-5,7 ANTI-SWEAT HEATERS TO WIREWAY AT CONDUITS FOR REFRIGERATED CASE SYSTEM. CONDUITS) WILL SERVE 120V ? '' ,� c� CHC 9,11 I I CASE FAN, _ — _ _ _. ._ — — — ._. REFRIGERATION EQUIPMENT UNLESS NOTED CASE LIGHT AND CASE ANTI-SWEAT CIRCUITS, IN ADDITION, � 3' � s ' r� �i � � —�-- I _ 0° I I ( (� 1 OTHERWISE. WIRE SIZE AS INDICATED IN o CONDUIT(S) WILL SERVE 208V CASE ELECTRIC DEFROST CIRCUIT (IF I ___... „��•� w �,T -- r = i = r ( \ ( \ ( \ ( \ ( �1 H �4% m (_ — _ —I SCHEDULE. FINAL TERMINATIONS AT CASE AND APPLIrgBi �-1 NOTE: CIR �lTS MAY BE + PE I t "`, 71 �_-u I _ — _ —�� — —--— — — — -- I �. �. IC GROJ D TOGETHER TO MINIMIZE � � / / / / J � � . r r _ _ .1 - ,0• "-•• _ ^� r T^ 4T REFRIGERATION EQUIPMENT BY R.C. REF L NUMBER OF CONDUITS PROVIDED THAT ALL NEC REQUIREMENTS ARE MET k _ U t hYBR3D HO M 3�, - �� tia , - r;:T- -��t-® PANEL CHC CASE CONNECTION WIRING DETAIL. ' 16.717 ' a I PROVIDE 5 LENGTH OF LIQUID-TIGHT FLEXIBLE METAL CONDUIT. i .rw �� `------'-'- _ r �' a --, ,-�'"'" _ y; f �+�-►® s L ./ / / / .J 2. REFRIGERATED CASE WIRING COMPARTMENT 1 3 ---- - ----- -- — -- — — -- —-- -- -- — — REPRESENTED ON DRAWING BY RECTANGULAR -� FURNISH APPROXIMATELY 12 PIGTAIL STUBBED FROM END OF Ij �G I BOX. EACH FLEX CONDUIT FOR TERMINATION TO REFRIGERATED CASE t n ; - LiJ ELECTRICAL CONNECTION POINT BY R.C. °' - COg 16.711 I GROCERY 3. CIRCUITS FOR REFRIGERATED CASES SERVED BY ` CHB-41 I cy I= TYP SALES UNDERSLAB REFRIGERATION PIPING ARE TO BE c PROVIDE TRANSITION FROM PVC TO EMT 4 ' ROUTED UNDERSLAB. REFER TO CASE ® fi s 4 (� TYPICAL REFRIGERATED CASE SYSTEM s I �,_�„�;, .� � CONNECTION WIRING DETAIL. 4. ALL UNDERSLAB CONDUITS SHALL BE 3/4 MIN. ROUTE EMT CONDUITS UNDER CASES, ABOVE. . .� F .. — �. _ ._�..: _. ._ . .�.. _ .__.... -.__ _.._ "� ___ _. , �_ m I,-._. _ �_-._ _._ __ �. _ . ._ ._.� .._.�— _ __._._._ w _..._. _�_.___.._ .._ . ._ ___.w.. — _ _ ___._M _�. ._. .r. .... ,�_�.._ " M______ ..,�w. _, .,._.w. _. .-. .__-. w .__w . ._ -_ _ ( j___ F V Y � 5. CIRCUITS OR REFRIGERATED CASES SERVED � SLAB) TO POINT OF TRANSITION TO FLEX OVERHEAD REFRIGERATION PIPING ARE TO BE � ;!,� B06 ROUTED DOWN FROM STRUCTURE AT THE SAME i 12 WIRE PIGTAILS TYP r }} I x k LOCATION AS THE REFRIGERATION PIPING AND 5 FLEX CONDUIT TYP 4 I I # EXTENDED TO THE FIRST CASE IN EACH I FLOOR : o I; I SYSTEM BY THE E.C. WIRE AND CONDUIT FOR � BRACKET CONDUIT TO FLOOR € I 16.708 PANEL CHB SLAVE WIRING BETWEEN CASES SHALL BE I` TYP PROVIDED BY THE R.C. AS REQUIRED PER CODE TYP � �j� 0 � R 3 � — — — — — — — — — — — — r __ ` PROVIDE TRANSITION FROM EMT TO FLEX ' . �"# _ —Q ' ISSUE BLOCK ' / #�-----Ir C09 CHA2 10,12 NOTE: PROVIDE 208V SUPPLY SOLENOID I I ALL CONDUIT DROPS NEAR REFRIGERATION PIT ED °'� ''� `�`�' t 1 CHA2-21 VALVE WIRING ( (2) #12 W/(1) #12 GND) I ❑ L I®J I GROCERY FASCIA SHALL DROP i TO EACHI REFRIGERATED CASE AND COIL. „ UNDERSLAB PVC CONDUIT FOR � s J IS ® � TERINATION OF 208V WIRING AT I I A MINIMUM OF 2' -0 BEHIND REFRIGERATED CASE BRANCH CIRCUITS I I CF B04 € I - �� FASCIA TO MINIMIZE VISIBILITY I I> MEAT a II A19 I CASE/COEL AND AT TERMINATION STRIP IN L_ HYBRID HOUSE DTB --- — 1 & 9 COOLER I COMPRESSOR RACK BY R.C. SOLENOID I t I ❑ I I 13 WIRING FQR CASES AND COILS NOT SHOWN rk /10;-7CASE ®� E T� lJ9 �i ?+ CHC-35,37 ON PLI,NS FOR CLARITY. COORDINATE WIRING 4 J NTS 07.25.03 ER02 II3 ED ;r'; J E EXACT SOCA I ION OF SOLENOID VALVES — li A18 WITH C. PRIOR TO INSTALLATION. \ \ \ r � I J ® ,„ , 11 CF _.....___.,_. j 12 l 0 LCHA2-19 t � 3 v....w:t+.�+r,...wo, „n;.q m>+. r.azn.v:'w++9row„w..•c .�...y 5 1 CF gin' s t r r NOTE: TAP DEFROST CIRCUIT IN CONDULET AT CEILING PENETRATION g ”I PANEL JUNCTION BOX WITH #10 AWG FOR FILLED WITH SEALANT I! ED I I CONNECTION TO UNIT. MAXIMUM I i A19 CHA1/CHA2 STACKED CONDUIT PENETRATION LENGTH OF TAP CONDUCTOR 18” CONDUIT AND WIRING TO PRE-WIRED PANEL IN COMPRESSOR RACK F BAKERY SEALED WITH SILICONE II± FREEZER 10 j SEALANT FINAL CONNECTION TO PRE-WIRED Iti I i - -- - -- ------ -- --- -- - - - - - PANEL BY RCIi i f — I , +� CHA2-37 I I I I I CHA2-6,8L CONDUIT AND WIRING TO NEXT COOLER/FREEZER BOX CEILING l; �; 1 I JUNCTION BOX ON SAME SYSTEM , ' �I t t I . G r LCHA2-17 H jj i CHECKED BY: (WHERE SHOWN ON DRAWINGS) CEILING MOUNTED WP JUNCTION BOX 1t" ' =�=-- l t L - M I I I ,� ,, �; , A17 �- l `r"• O � DRAWN BY: TLC NOTE: CONDUIT AND WIRING SAME WITH THREADED HUBS AND GASKETED 1;4,4i� "�� � 4 - — --—— —-- -_ — —— -.- — — — — --- — — — -- — I SIZE AND QUANTITY AS WIRING COVERPLATE t€ I ,�' C10 I"''`. -" i �. _ w HYBRID HOUSE LTA FILE NAME: RE1.1 i Gal 5 �P4 t G , TO PRE-WIRED PANEL (UNO) t 1 I IZ, BAKERY It x, ,., r �t B02 I t. , PROVIDE CEILING MOUNTED MANUAL SWITCH s COOLER GHC '< PROTO CYCLE: 012712 j , , �; 9..✓ , 4 Y tem—, 3 m2 ear 4 1 i A A SQUARED TYPE K CLASS 2510 OR EQUAL € � DOCUMENT DATE: 041012 WITH NEMA 4 WATERTIGHT DIE CAST ZINC I t! °� t 2 CHA2-15 �d1 f t \ \ TYPICAL COIL °�� ,�; ,J- f r i ❑ L I I ENCLOSURE FOR CONNECTION OF EVAPORATOR r��,r COIL FANS CF AND OR ELECTRIC DEFROST FI w "" "" I ' I 1 C ) / � '� �� � � 3 (1-67717)- I 16.710 I �-••,--. r- ._ _ 1 • i (ED), (WHERE SHOWN ON DRAWINGS) r � ,..._...._.... ._....�......... .., .,�'�r ��. ._..,..»._...._......99..9..9..,_ .,_ �. .� -. ..�..,....:... ,...._,...,. ..� 1.„, � 9._99.. ....._._......9...._.� ..,.....,,...._., ;.�. ...�. , ..,.,.�,,..,.._...... —....,..,.... .... _.,.—...._.�...._..,.., __.�...._ w. .....,._.,....... ,..n...,,,... .�.. ...�......,,., .... ...•..,.,._,m,Mn ..,R,._.,..,., �. _ _ _ _.._.-.......~r _._......... 7-'�. 11 _ LIQUID TIGHT FLEX CONDUIT TO - - KNOCKOUT ON UNIT. FINAL I A ( REFR GERATE CASE --- ----- ICONNECTION T 1 Y C I 0 COIL B R � � � 3 ; g ELECTRICAL CONNECTION POINT, TYP NOTE: DO NOT LOCATE WP JUNCTION BOX DIRECTLY IN FRONT OF DISCHARGE FAN OFFSET TO SIDE. E BAKERY ! ' , mss"I i k - I CHB-5,7 7 >< ! 4 I UTILITY . _,� I d € J CHB-1,3 I I � f " 1 Bol EVAPORATOR COIL WIRING2 } NTS 05.29.09 ER01 I r ti, 16.716 TYP 01 CHA1-1,3,5 `�+' 16.717 R 1 F �'1 i �. � CAKE � � � f J �GtN,�F� REFRIGERATED CASE ELECTRIC DEFROST FEEDER SCHEDULE � ��7ECORATING '' j 4`` 72336PE NUMBER AND BAKERY f. " `�w A01 NO CONDUIT EQ. GROUND NOTES SIZE OF E 0— o SIZE CONDUCTORS WIRE `� �,� OL OREG Vit, �� � t � ,rte '� �'1 rF''''� ...... 'eQa'''°y �✓''" d ��"�►� , '� ��(je ❑1 1/2 (2) #12 (1) #12 E.C. SHALL PROVIDE CONDUIT AND WIRE FOR REFRIGERATED �.r - ---- - = '•°' w ' ❑2 1/2" (2) #8 (1) #10 CASE ELECTRIC DEFROST TO DESIGNATED PANEL IN D COMPRESSOR RACK. FINAL TERMINATIONS AT CASE AND AT � ,� �.� -- •f PIRES:t3Sl3Of2�93 ❑3 1/2 (3) #8 (1) #8 COMPRESSOR RACK BY R.C. REF DETAILS 3-RE1.1 AND mss, ® 1/2" (3) #10 (1) #10 4-RE1.1. �._.�_.._----------,^.----_..,�_ --- f' 0 3/4„ (3) #8 (1) #10 C11 © 3/490 (3) #6 (1) #8 WALK—IN UNIT COOLER FEEDER SCHEDULE REF 1-RE1 REF 1-RE1 REFRIG CONDUIT COIL FANS ELECTRIC EQ. GROUND ELECTRICAL N0. SIZE (CF) DEFROST WIRE NOTES (ED) PLAN 3/4 (2) #12 C2) #8 C1) #8 ® 3/4" (2) #12 (2) #6 (1) #6 E.C. SHALL PROVIDE CONDUIT AND WIRE FOR EVAP. COIL FAN (CF) AND 9❑ 1" (2) #12 (2) #4 (1) #8 ELECTRIC DEFROST (ED) TO DESIGNATED PANEL IN COMPRESSOR RACK. FINAL TERMINATIONS AT COIL AND AT COMPRESSOR RACK BY R.C. REF 10 1/2" (2) #12 (3) #12 (1) #12 DETAIL 2-RE1.1. Y 11 3/4" (2) #12 (3) #10 (1) #10 REAR REFRIGERATION ELECTRICAL PLAN Q 12 1" (2) #10 (3) #8 C1) #8 1/8" = 1'-0f, SHEET: co o.„ a 0 i BUSWAY LIGHTING NOTES 1. APPROXIMATELY 60 DAYS PRIOR TO POSSESSION DATE, A REVISION OF THIS PLAN BASED ON THE FINAL MERCHANDISE LAYOUT WILL BE ISSUED TO SHOW FINAL LOCATIONS FOR THE SPECIALTY LIGHTING. IF MERCHANDISE PLAN DOES NOT CHANGE, THIS PLAN WILL NOT BE REISSUED. VERIFY FINAL LOCATIONS AND EXACT AIMING OF ALL LIGHT FIXTURES WITH STORE PLANNING SET—UP SUPERVISOR AFTER DISPLAYS HAVE BEEN SET. 2. BUSWAY: OWNER FURNISHED 40A, 480V RATED MAX, 120V CONNECTED, SINGLE POLE, SMALL FRAME SIZE, WHITE. PROVIDE MOUNTING HARDWARE AND UNISTRUT AT STRUCTURE AS REQUIRED. UTILIZE SUSPENSION CABLE FURNISHED WITH gt4 BUSWAY SYSTEM. INSTALL PER �, o~} REF 2—GE1 a G r REF 2—GE1 ` ' c ui o — o¢ �Iti _ _ �y: 1 YW � ——�--—— -'------- MANUFACTURER'S RECOMMENDATIONS or�- zZ W w �� -- 1 ; � � 1I s W o� o¢'¢ao�z Z'z w w .r3 w" Y I r ...� _... -..-.r.ww ,.... w. _ -- (Y O_Q}^0ON_.�?^�Woawm FURNISH AND INSTALL n ' � w�_— I ` 'ER KEYNOTES it �w�,��W�W�Wz� < �. I ._, ,.._.wK .w af-O�WF^WX�aZVl4?- i I" L i = dl , ►E j COLER x "< N—W.}a O SENSORSWITCH MODEL N0. ; k � c i I �,M b ! ��t, l " o~° W U. W ! y ;tl p 3v�a��viW��oo�z CMR-10-LT CEILING MOUNTED i _ .,��"Ms I� I$ t Zia o�a�Wa�QOQ¢3 OCCUPANCY SENSOR WITH 5 r k ,I; €ywrc ir�� , IREFRIGERATIOIV i;i 16.027 BUSWAY PENDANT POWER FEED UNIT: a �a��¢� wZW MINUTE DELAY TYP OF I `" I mzz o~w W W W"o ON � n5u # `"'��J COIL, TYP ,d `_-. .... ,.,`_w�. w. ._.,-.�__,„� w,,,_ PROVIDE 3/4 CONDUIT FROM STRUCTURE 000 �cr�� c>�`'o�o '�' TO PENDANT POWER FEED UNIT AT BUSWAY. _ coo o COOLERS AND FREEZERS - �� - � � _,� u ` (Q W" s ar a 0 - _ .,. . +,. — , . -....,M. .w .- r _r.. ._ ..—.. . w.. ,. �w .—. _w .w �.— ._. PENDANT POWER FEED UNIT FURNISHED cn I �ti -fes -._•t � �+, �.;�-.. ���Nzo��..acn¢�ar¢E-- � ..I..,, �Y� WITH BUSWAY SYSTEM. o W�W W�p - � 16.715 JUNCTION BOX PROVIDED WITH 3*1 COOLER/FREEZER PANEL FOR N CONNECTION TO LIGHTS AND/OR DOOR ®� o ��—• I ;�-- ~ --- : ..,1 , ��. ai HEATERS. PROVIDE WEATHERPROOF iAW . �� ww.. w EXTENSION AND COVERPLATE FOR �!,W ,,, m o BAKERY �--, ��� �� I mar;.* kr -"-" "" "' RECESSED JUNCTION BOXES AS W �_ � �, ----- f �'' �-� I REQUIRED. FINAL TERMINATIONS BY OZ � , REFRIGERATION NTRACTOR. �Yo •= a I €I I LCONTRACTOR. E ...,..,......y �xw„.,.. -M"j p c m udz ell III _ I I'<-•' + ALL CONDUIT DROPS NEAR GROCERY FASCIA SHALL DROP Ioo A MINIMUM OF 2'-0" BEHIND FASCIA TO MINIMIZE VISIBILITY v V s I � �I � � ��?���,��► � ��'� ��' `"� VERIFY EXACT LOCATIONS � I ` OF TYPE 58 AND TYPE 8 i LIGHT FIXTURES WITH ST SET-UP SUPERVISOR PRIOR' TO INSTALLATION � { � G I ""� � � y�"P�� �'i"�9 /'�,",�`h �inhyt''",,w� ,,✓� ��id�m� r ,._..,.."'�-�,,,, �,, I t.....,,xx_.w.xw.�....-.w,,,,..�.,,, ..,w._....____..._..w,...,�.�_w___.. ....._._ ,�..�.....�....�..._.:...,_,_,.—...,..._..,...__.._ _.�.,.�_......,_. _ ,w._,�., .,,._..,_,.....,,..,..,.... _-...,..w._ w_....w_,w—.-�... `� I O ,_...._._._......_,.._,.,_w.,,,�,.,.,.w.:.x.w�..x.,........�,:�w ...,xx,.._.u...._...,w�„ww.,.,...,.�.��w,xw.,...,,W.,�.,,.�ww�,....,._,x.•.�...w,�.,x,._...w.,.�,^.�,�x..w._ _ . _,._._. ...._,_ ._�......_._,.__.._ ._.... ._�.,: .�..._. , __.,. ......._ .�._.•..x.—,w.._..x.......,.,..w.,w..x .xm....�.�....,......—.�.rr. �_.w.-w.w�w...,....,.,.,rWw.....�.,�.,. ....w_..,..��..www { ..,..,_.w..,,..,.,.........,...,.-.-w- .:....._,.-,..... .,...« ,.,- ,,..,.._,...-...,,.. .».,...,.........._......._.....»..._,..�.. .•.w.'y.,,.w.....•,« .........,,.,.. j �r. .tA4. 1 �'P� �' 1 km .€..•..�.. ....,.,.....,,...,�,., .,.,,,.,.,,.»..r^.� ..�,.........,...�..w.,...-.,,. ..,. :.,ww..,,.�...,,.. # ,�..„�...,,...,�....,..M,..-„.,..w.,..�.., .w..,wr.,,.,,......., �._...._.w_...-..,.�,..:,,a.�..�.,...,.-.,ww.,..,��w,.�,...,.. � p� �i t �.'.; I H ...�....w...,wM:,•„ ,,.,.........,..,,�. ..,. x......,. ,.�.x.,,.x....,. .„ ,,,m...,.._.,.... ,.» .....:.w.,,�..ww,w..�,.......�,.w_,,....�.......,.,.... ,....:..,.,w.__, ..m,...,...._..... .�w. , w.., -.w.ru,._.r..,...� ...w..�,..w........,w,..,.....,....� ,....,.—.,,...,,.. �w.,..,.,,_,,,.,.f�. �,..,'; ..�...:�..,,.•-�.w, ,......,,,.�.n. ........x..,-,...,,.«..x�,..,.,..,.,..... ..,,.:.:..»..w,..,w.:...w»„w,.,..... _..r._.,..:._. ,.,., .....w..xw.,.. m. ...,,.,«.w,.. ..,...w.,..,...., w......rr...�.... _.. ..,,....,.._.........,,.,w,...,.,,...........x,N,w., >.�...W,.,.�.,.ww. ..-.rr..�....., m. � � � '51 ✓''�`q'+ � �re�A'n ,,r+'�' �°>� ,+/°,nl ,,s� k`,� �j� �t � �/'� .. 4 u V ix.,�',$cuL$„Afd<ew,1 3 Ry Y Y' ",,,, „pd" r� ✓'1 .+r'.r” ,� Ir £ } L.c J \xj! t �Et y R s:..,r p �y�[� c p �r °j' r•' IC, ; E F J GC> i off:Y �( h �n� 1' 1� I.J 11K GJ d e+” n"" B v^°a h �✓r �4y"TM ___ d?..,,.. I .w «. _».,.5 L H1 PI `n�F a ` �+jl �, '� �x" r"�'� '. / ,, , `;; y �, �j C77 Q�� / P:.. Q \F• ,sd i r :., ' ly` y!'',� \ .F `v W :. a = LO r`' ^ 4. 8 f y n ,Gr 14 pr m 4 ` � ., yf' 'T ,, ;3: � :4� f 58 SIMILAR, TYP ww. - �(u{ 16 715 , `��r,'r (PAM �$ �W } k � a� � �J r ,t"y�+°� I PAR;T1-_��. ° 's w_._W,•.t:_.v P {+ wy ,�",. E3 I s 0 t t f 1 •.•rn: t Vit".: 1 ", �%-....�:,. •4� 1 r ..w xrru„w.n .xv,r.,ww , w w.ww:.-,.,........r•,..:..,r._•.rwm_w.....,,...._.._...w.....,.,,...M•..._,.ww..«...,wux.,,..wr«.,..:ww.n..,.,.........,...,.,....w.....w..:............x,..uvr,.,n..x........,....w»+.,...,w:.,r w:....w....w....:....w,a:..,r..rr.a••.,w:.uw.:.�wnr�..«n,�uw.w..wx.v,...:www+ ::,,«....<.1 .....,...._._,...^., . �..... '• __ i..:^� �..i uwr�::m. 'q,./,• c h 1 f ....._._.,�. ,.,,.... x,....-..� w....,., .,,.......,,..0 .,,-.x,,.,.w........,,�...,.,.,_....,..,.,.,,...x.,x..,_...:....,.w..,.~�...,.,,.-.x.....",.,,....w....................,w.,,.x,..x..,x,x,...,.,..,,,.....,w..�,.,..�,.rn,.,.,w.•..,...x..,».,..w,:,,,.. .x",.,,. ,..,w„«W ,..w.,.,.�r„aw.-.� , � .•.. .w. w,..,,,_ ..., « .. ...«...,„,w . .. 1 i.,.,. ....".. .w, .,ww.....-....,n .... ,.,..... ,.u,.0 w,,. ,.,n.« .,.., . .r. _, ...w ...,,....,._. ... o-.. ..:..... _ ,.--�----.w•t- ,,.e._..,..w..,..,...-.....,._,.,_.._-,....,:.,...._.,,,,..,,,.-.,._. 'w•Fa,a-a.u'....,ue.rra..a.>�w.We,.etr.,,.,u,,..,.....w,....,.,.w �..,.r.rrwn,^na:xvs.vuwr.-...auw.....:.wer:,s,...mwn.,w.e,.x...wevoe:e,_,n.rrw,..w.v:w.,+au,w.,x.�x!�:.,..amr,.w.vu:.ru.,�w,:.v,wuvu»,...n'u.,u ,.�_,w,•,_.....Yw',...z.x'�na,,..u:awlumn.l,wuewr ek u:..aau .r, ...:,.d... .,.. ..,mow. .,.x...,..,,... x... ...,o. a..,,....,,x. .,R,�.,,,�-�,� A,.....q9 p9: ..,t,r „x ,,,.. ..,.w.,„:....,w .,.,«„w,,.,....,x.. ,._ ._.w....,:� p ._.....ww._.....-...,...,..�.,..,..,..,,_w.._,x....•.._..,.....,._,,_........ E..,"„_ i a � v. f ,."�^` >• ..w�-,"'�"»'�r G V y1raxnmcnrnnytm,aev�as:ene,u•,avium.,uuwul9raxem,mr,ewY�ww�umeasermwsssmmnveciewlrmawmommu;wurz;eluaa,auxs+a�saxr-. mr:runammcwraeu.ax,u.as::mnr.�:art:.,.m�'^:a+nu,aecseeyea^wvsn�,.^.uws,.aw�+cnLr�=.:mmaarte:.xa,ar i#'- t •' J J W •• ••,•�' !� q W t 6 ,, " �� ”'= .s '� € �4 w �,�w' c� IIS 16.715 � 111 s 3 O ,+ �� MECHANIC _ 4 b a b € I-- �; GROCERY _ate; Jt�_ ._� .- �a� �._ 3f FREEZER EDC4 S �. . _ ___ _._ _ �'� _ UTILIZE AIRCRAFT CABLE D .w__.www.. Lww -. .r, a E 1 OS3 o € f `� _ r «_ DAIRY FURNISHED WITH FIXTURES TO " .I w L_ w ---.— .-�..--�-. -�.-.--�.w•. COOLER � SUSPEND TO 9 —10 INSTALL 3 € ICE CREAM ------- ( OS3 , -� x E w�" EE t FREEZER I _ °0 I I I G4 I PER MANUFACTURER'S # ' `' -'° 50 TYP RECOMMENDATIONS, TYP OF 18 b `± S 7 X4 .'.r•'%s{'f� er.+"J`.f,�. ` r////,..,+".,+'.1'r''d/r`!',�e' R ¢� � � �....w....,...� i i � b E ,,.... ,n�'�'�..s•"'" `,,,«"^' �...x'.�" �.r+"".. ��,,,.. � . � t4� �q s�����:+",p�+''/'".•'`��/e�'� ¢� I ` � � � � 5 9 ,..,.�.,...,..w......_...w....,......0 I.,,ww..w.....,..x...,:,...,:..x,x...,pw�..w.,._..� 6 J �,,• ` �"�'+� `'� f '�`� E },r ,t �e � I j '� t C ]k•,,.,,.x...,,,.«�-tu,,,. ,,,Af,ww... �,,....,.:i.,e. �''Ly:.,m �,,.•gin�� o s �� q�xv,xw, xvf..'n.r++.ra...wma�vwo.>w�= +.,..rn.r..w�wn«ter.wu.,em�u::,�r, ...,_.... .. w......,........-._..._,,._ ..,,... ..,_,,,. —, ..�... _._.. r, ,. ! ,. f ' r-.::.W".�-." •;� .. L"� • ...u,w,w,vnurmm, '.:n.,,sawuxmnsrweuswc::wr..wowvr,.:u,u�u.,a,:uluum.,w n vu:•++,.wam+u-ra:wR:.:wawu:w�es• h •�•� —� O ...,.,,. ,rY.,..,�,-.. ..,.:,.....x.xM .,:w..,. .w.»..,w«.,...•,,. ....x:.,.....: x1t,,e� ...,,,.......,. :w...x.....,,. :,.,.....,,....,.....,. .,..,,r..x..,.. .....:..:......�..ra:., .,x.,.,...,......-.,, ,..... ... - .,.....:,.,w.,.....:.., ,,,x.:,x.., «.. .,,�.�«.,«.... :.,x. ..w,Mx,�.»..,.«,,, y. .wna+,z,uw tx'at�r vH�1.. K �a�u�.'?ar�m.evstireraaml3en. .1'aia,mrolvn '.a•rvxst�;v.����na�uwe�'• «rncrr�5a .eie+ari .u+wir.,6-,cm�.u�. �cxw,wryavciaa,� xnr.� su;rr�s �,,,x., r �1, y; G •��i c .P.. ...� �.w...�„_ —qew..,,,. ....4 � 'R p: "'"I`dsaa'�an.,ee�,y+ri 1' "bu'�''i�'++n"tmcra's�� "�n`m�'"'"ansxi�'i'°'y �+ ,�p. �'n"4& M'�aTlsm"" ,tt"'"°m"" '�'��?", �nr�."ua4c?icc+ aax�,{'�exms�eac�F � � c � t 6 d 1 ,+Q `'r, �1. r� V •� ?� .�T fa � ul � ))7 ;,, �, }y c � � ra i � I � � � 1 0� ,,,,, .A i k p., 1 i 3 t 1 C 1 S' i j _ 4' [,'• t , F' i.� t F t i ! { ; i # tl 1 I� I I I a! 4i E",t �. -+•s-an'.. rw.u,n%r+{' ^'r"Tat�su�ur�.rr''u��a .au' rAas:' x.,,.«x,ax+.:�.=..i�.:=c..-�sx/✓Y',rs�xta.nsr�aart Mcx.. c7�icz°�-..tta �Ra"ys ura•sm,a I,n'.nu+rir�arcel?�wpr.+c»;.� •:e!ieav+�eenpwe,.M�'r*u•+nenihwota+Naxiteeume+r,,; a i t. [ s � A , 'snPa'f'"ars e• , t .i . �'� ��C ° � tm--�r��« •-•—mai..,•-^� �, t t �� � .:•�---'-'--_;ry-...-:-.-.�y--,--..... .� ,�..n,.... x.�., �..,,x.� # � � � 1 L r .,*;�"""»-^----^""""I�� _ �.,, ISSUE BLOCK FURNISH AND INSTALL U TI LI ZEf SENSORSWITCH MODEL N0. o € WITH FIXTURES�T� Slz"SPEN ' 9'-= ";•' €, _ _ t 1 . �f CMR 10 LT CEILING MOUNTED INSTALL PER MANUFACTURER'S OCCUPANCY SENSOR WITH 5 3 - MINUTE DELAY, TYP OF �3 d 1 I RECOMMENDATIONS, TYP OF ROW b a ^'^ ✓ � COOLERS AND FREEZERS a � ,t' � �`� r`� � � � �`•, �`' ,� \ F----�.. ° �'—'�rn`x,wr�xeui+r>.'rux �1€ r, LJw:yw",""�" Iw...,x.. .,.,..w., .,:...w .e� ���..,. ...,.x..,..ti.4�� x. .... 9Gw,r,,....,,«,.w�""`K"...xx.4Y,S ".=W.:.,'•, STOCKROOM � �, I I � � — �. i L w i--% } i a - *E ----�-_ # I s ,r 11\1 CT e I I P I 11Z L1 Y I I ! AAOI INITPn PF OkI iG E CPCITI IC:NTC ilk! TNF C:FNEf�AI I ()CATIONS CF-ICW1V i 19 I , t, t,,�� ,�.,. .. , ..., . �� SUSPEND TO 'f —_. w ?R --- C�1 F i ON PLAN.(IOCATE SPOTLIGHTS A CLOSE AS POS IBLE TO DIRECTLY_ VE TABLE ' r- o- . wb � RR. TfONS-0 --DlS_P �rY BI'N ONE R -T ES--�hI�D •BM --A c 1 TYP ��,�^ fA 1/'� }^� +12 —0 tae A" nF O i t f �R t i -i- —---t w 1,:_.�_- wt E t, w� .�5 tY._�.. l._....._ .�+w ._._ �_n• .__ w.. C C L.`�� ._...._._ ..._.. w._:»� TYP I sk L... E ` v� I t SPOTLIGHTS TO EVENLY MAXIMIZE LIGHT LEVEL ON THE DISPLAYS AND MINIMIZE HIGH I ` , .ww -.. .,. b a ,�.a: b ANGLE GLARE. HALLWAYJw `-ti''v E i (4 ----1•—� � 1 i 6 L'�..�+� i r., � t,' r #� F^'_._.._..— �...�.,._.......__.�•, ._.f.. . "� z ' 27 AT STRUCTURE FOR i€-- nj N n 60`-0") i i r, -i t , N �k L1 D3 16 18 tt FUTURE WINE„LIGHTING. � a � � 41 , » PROVIDE 3/4" CONDUIT t �. � t_..— —. f_. _._,_.... _.. _,._..�-..�...; w°� -�.•->�;; T� PANEL lot '� t a tL i i � •. ^--- v e �/ v v v . v v ,Y v _,. � v, u.•..,.,r....1I�._.._......V � .- ..��� ,, tM } . .,,.,.. ..,.,,a..�........,w.,W.�•_w:...:,�...:..,,.x,�.....:.,.....:..� 3 � . .� 1 _. ,.....q ; +�W � ; ay �,'� i IM I1 -.__.____ t € I I i q .� P • 1E 7 E F 6 P 9k o , # aa: "_.'Ile — a Zia 1, J �' °7 I 5 8 f 0 2 E -- ...�, t I ,, ; , I I --�- ----- a WTI L�TY € ��� �� ° �€ i ��,. � r r,...-.... �.�� � �E I � � � ..�... .."�.� � f' [ ---�'' --# { P II 4 E o CHECKED BY: � €R1'p,��,r. t.p.....x,.,•.�....,...... �i`>•^'^'-'^^--� k' { .:tFr'^•.`a iaw„ �.�.'' .. S __ '"^"'� c'.€"""!Ii '4 jj � � i � � t_ �` MECHANICAL DRAWN BY. TLC `D� ^ € i r� :��i � E� ,y i X£ y s"^�1'".,� t.:i�l ,�9'"'�� 'A����i�":t'� j i I � €F /� { /� /� /� /� /� /� A /� ,� � •osuc�casas::�........,,,�,y�..,....,.x.y^y\��taxrcrrewc.�.�»y"S ,..,._,,._. ..,-.....� L'r s S8 i t` j.....,......,1 -...,.+:.-w....+.......-,....._... 5 �' 1 ♦ R �"•p' °• I ; I P Ef��t f. FILE NAME: GE1 �-»- 1 1I I..., r.% ! i_71 IF y.,..w.w ., w.......w ... . »...w... �..�,w .. �.w....., ... w .w.,� Ina q #j I IF i •• , 1 I . € PROTO CYCLE: 012712 � ;; w t ..,__:.,—.�,�, - I� �� t .�.�... � � �I,, •iE���,.w" �� � �I� � � 1 f ► TYP o 16.715 r S— �: � 4 � .�,.. e DOCUMENT DATE: 041012 CO 1 E SERVICE _�--.,x.._„ I o i EI L DELI I I I ' a iF a ,u,w ,I �ODUCE r I a f- 30 0 25 £ {4 �. SUSPEN[ Ie ISA, I en } r 1 �' TO +11'—p" MEAT € '` �. { COOLER / j a �...._�. ......._ ,, X16.715 ' v cv a'� n � 4,00 s wumallum, 68 TYP OF 50 TYP II O ; e € 16.715 I r�'�--�--- IFI 110 P ` 6 L FORNFROW, � i t '� � i �s';_.•'.•�'....'—: � �� iii# i I� t[i'� � `,4j(� � � � F.-�--� .1..4.� �C) •.� fir, b .'� �' f � f> C00 R x 16.715' I FURNI H AND INSTALL PRODUCE S t " = SENSORS' ITCH MODEL N I �, - ° I 1 € O a COOLER x,11 i °` ; € �12 �� PR I� S .: € CMR-10- CEILING MOUNTED 6.7. 5 2P1 ��� ` OCCU PAN Y SENSOR WITH 5 I r a Ij�•++..r,.....wxw 9 t, # �'% ::+•w.....",:;:^x"w.'.'^""u,l'.•.i GCMiH113W.W. W A i 1 4 - t( '`a lC `. , -,.w,.....w,n- _._ -....,....._.w_..«..r_�.__..._ NN 1/1 11 1 Tf'- /1 1"-/ • / T I'1 I�1� I �,,d ': � ♦ � , BAKERY -- --- - MINU I tw ur.�H`r I Yr yr k II� �� � � � e �1� �.,._-Q,��� •—_,.."" ����� a•4�---°--�ti-- M;s�--'----- � �`. �"`° � Q I FREEZER I COOLERS AND FREEZERS ; r. °`'I €_ _ Ssv� f; 16.715 FREEZER 72 3' E tW/07001 � 4RT 2/2) :'EF 1-GE1 ,:l I `' O 2 A. t 1 ORE N o0 k, H 2P 1 h -- J : i. I ' 2 Ali REF 1—GE1 f " I � ' REF 1—GE1 ! u °`�° t �i �#, f -! ,� C`� S ...v .� �.! ry�47 i 18 _ =6-"=-==_ PIRES:06/30/2013 REAR GROCERY LIGHTING PLAN. 7. -2 — TYP 1/ �.,,LI.�1_G 1 $ — 1 —0 I s a s 1 I� CEN ITER d I d .,w.,. ,.,,,«.. ...w_......y M^.+.+,_.,.,,.+,.��...,. .«.,..'4f{"'�/j7'^'^. ....�,. 9(^'''e.�,ro'^'^�]f+.,,I kt ! ti q1 j� Ftil Y 9fI 7i I ? 7 i �Ay a 4h2P1 12? II _tvA 9 I ENLARGED FRONT GROCERY LIGHTING PLAN GROCERY LIGHTING / PLANS W Y Q Q SHEET: 0 oa Q 0 EQUIPMENT KEYNOTES • SCHEDULE NOTES 1. PROVIDE CORD AND CORROSION RESISTANT 16.220 INSTALL PREFABRICATED ELECTRICAL 16.650 CONDUIT SLEEVE: PROVIDE 1-1/2" CONDUIT PLUG, CONNECTOR AND WEATHERPROOF BOOTS. DISTRIBUTION CENTER (EDC). EQUIPMENT SLEEVE WITH BUSHINGS ABOVE BAR JOIST 2. PROVIDE MATCHING CORD AND PLUG. AND INTERNAL WIRING ARE SHOWN FOR (UNLESS NOTED OTHERWISE). INFORMATION PURPOSES ONLY. THE ENTIRE 16 659 CONDUIT SLEEVE: PROVIDE 2" (UNLESS Z 3 3. WIRING DEVICE ON DROP CORD. REFERENCE ASSEWIR DMBLY WILL ARRIV E COMPLETELY NOTED OTHERWISE) CONDUIT (WITH PULL DROP CORD DETAILS. ASSEMBLY. WIRE) FROM 8" BELOW CEILING TO 12" a ,.._..,...:.:r..,.r.:...,.......:.:..,.,._,w........rs:_r.....-.w,,"............._.,..�._:,:...~r........,,.,..:.,.,.,�.,,.v..,�...�,.....,:....�. ,.:�....,.,.,..._..,..��.,.,..........,..,,,,...:._.,.�..,............._.,>...,,�....:.r.....,...,,"._,-...,,..,.-T..,.,,�..,...,.._..,.,>.�,..,._,.....,..._w:,..,.�.,,,_....,..,.m,,.,._...,�,._..._,�.....>»,>"......�......_.....,..:..,.....�,:,.._,.,,~.......p"_,-,,.,.,...,._..�......,........,,,....,....,..,.,.M_....�,...,_..,...M,,,�� + 4. WIRING DEVICE CIRCUITED TO SHUNT TRIP ABOVE CEILING AND TERMINATE WITH 0 EXHAUST HOOD: PROVIDE CONNECTION TO_ -30A; + -FI-N-ALI BREAKER. 16.51 BUSHINGS. "`CONNECTION TO EXHAUST HOOD CONTROL PANEL PER „ • __.__.Co-M' � -• � � . � � � -� MJUNCTION X I I H T T 16.669 DATA AND PHONE CONDUIT: PROVIDE 3 ._ ..... w w. _. ....,., . _.., tw,.�,.. a LL..�.�,.. ._y -..:._.,,.,.._ .._ .. �.....". .....�.._,..�_._ ._.. ..,::_Y..,._., -. ,.�..�_._.�. .w. .,,.-..�..� ,.� .......�...... P_AACTdR:�.B:Yw���,ER.S_. .�,_- _. _.._._�_.. W. . _..�. _.. .-...,.__.,_. _._._,.__... _....-.aw...... ._,w-...._..�. :- _�.._.~,. _... .._.....�.:. ....-....., .�..,.,...-...._. :.�.--..,.-. ,- '11"D1 _ ._..-_.... ..� ..-._._.,_,. .:W.....�._ � e � " �}� MOUNT BO IN LING TIG MANUFACTURERS WIRING DIAGRAM AND „ € r 9 3 COOLER BOX WALL AND CENTERED ON INTERLOCK TO SHUNT-TRIP BREAKER(S). E j COMPACTOR 3 13 " CONDUIT FROM 8 BELOW CEILING UP TO I DEODORIZER 3OA, +�0 Yc � .a, EQUIPMENT. PROVIDE CONNECTION FROM EXHAUST HOOD BAR JOIST, TURN 90 DEGREES AND ROUTE WP WR, GFI, +4 °' --- - •-- f k ►� TERMINAL STRIP TO EXHAUST FAN ON ROOF. TO THE TOP SIDE OF CABLE TRAY WITH I ' I 16.514 +96 6 METAL CONDUIT BETWEEN 16.513 ROLLSEAL DOOR CONTROLLER: SURFACE CONDUIT CONNECTOR AND BUSHING MSB i �'�'�° ��� „ : a} EXTENDING NO MORE THAN 1 OVER CABLE 14 ., I EQUIPMENT TO FACILITATE MOVEMENT OF MOUNT FURNISHED CONTROLLER AND EQUIPMENT FOR CLEANING. BATTERY BACKUP MODULE 12" BELOW TRAY. TERMINATE WITH BUSHING. iAlWMJ6, eMeY:G.r;Xi,IhMu,.4x„Wldw Ninl..:..t...r..a..Ju.rc:iWNir K'nC- a :. tlt twvcU N c rrn5. '.`L.i:..:n.Y1..mh vG.L1v4"a.'..u] S l4]F% XEIL' iR..0 LISIY.:s1 1 Mf. _ yvbw ';,.Y" ."✓F.Y,L._., 'Y .IFL' r4A" uYA: Nw w:..». 9wi6i 0. Y U.0 .L'et'sL*rd n +"A'Ir�' I .11lLUYR3.60.u.1 1 'r _ .•.w,.:n..rm. .m..:..v.a.h«,.:+n...w.+. ...«.,.•....:r..v..:w.+-_...... WE.L:...':5..:.vx.i'i.'.^ v_:R1' +- 5'Gr 3,na., ...r..,....,,..,.n.,.......wr:. PROVIDE N FNA CONNECTIONS .�w I FN{SH CEILING R 1 W TOP 1 708 0 DE WIRING AND L ED CEL G 0 2 LO OF I� `../ "'""`"-0 { �t.'~�caerr+ .ms�w uwvwnTux�eu,s:pnuucxniRwc,srcrmevua.a.tFanw �waur. mcry,•.w+an� ,rr.;wrnscr>timaw�aa,aaa ,ei.��wsunmermvn�uev��rtuswrw.a.wa.+°s� �w .5..~! r~��wG a A A � N } N , I ' TO RECEPTACLE. RECEPTACLE FURNISHED p y 13 COOLER/FREEZER BOX IN AREAS OF WITH REFRIGERATED CASE. z z W W z< w w, i 16.514 N {T ao�� z- �,. 16.609 16.6091 ALL CO DU DROPS NEAR EXPOSED STRUCTURE. CONNECT FURNISHED w aQ z „ » Fza aW Z Grp t 14 EQUIPMENT ; GROCERY FASCIA SHALL DROP CORDS AND PLUGS BETWEEN ROLLSEAL 16.712 SURFACE MOUNT ON WALL 24 BELOW � d ao-FW��ao� n + ! s x a zo a �aW 4 i H � , � L1 D3 + ,�� � � 1 16.650 �1 A MINIMUM OF 2'-0" BEHIND DOOR EQUIPMENT PER MANUFACTURER'S COOLER/FREEZER BOX CEILING FOR � °���� "'Q�rW��m A r r", "~„_-..-_ M _" ._.,- ~__ .. _....-".. �,.rW 4 3 4 C O v� x of z(n I }v � w�.u.t ICE CREAM �,: - - - 4 ,� WHG� tl FASCIA TO MINIMIZE VISIBILITY WIRING DIAGRAMS. CONDENSATE DRAIN HEAT TRACE TAPE. t,_ n.N�--�N wWWp� Q t FREEZER EF Y € � x +10 -6 A vow ��-a�wz wm alp r'. 3 `. �, v u-Z'o rvooi--awww ;.� , 3 �:� � �� PROVIDE LIQUID-TIGHT FLEXIBLE METAL z dwzpow c,o ` t ; _._ _.._ __ _ ,. _....._ " J__ t 16.514 ROLLSEAL DOOR SWITCHES: SURFACE 0 3v¢ 3NWwo�ooF-Z �;F { wiz o �n z o W � �.._.w-.�. _.._,..-,� ..I �. :.�.......�..._.:-{ t: CONDUIT CONNECTION TO HEAT TAPE. 3:# r ,. xi - ~� ,... w... "_ .. ". .... �..._...� _ . -,.. F S D SWITCH +46 . ~ 2,0-�o- m a w w o a 3 3F 16.715 �t � i MOUNT FURNISHED DOOR WI oo w DAIRY I PROVIDE CONDUIT AND WIRE BETWEEN 16.715 JUNCTION BOX PROVIDED WITHQ�HQ� Wao��zW� + rj "�'a a COOLER D �ZZo�w�Ww6wop&W G, RECIRCULATING 'k SWITCHES AND ROLLSEAL DOOR EQUIPMENT COOLER/FREEZER PANEL FOR opoW�,W���c>_owo I rl n` 1 L1D3 cnW�-'��w�'aoac=>am�� PER MANUFACTURER'S WIRING DIAGRAMS CONNECTION TO LIGHTS AND/OR DOOR t=- v, no►� ozW�wWoo �� �� ► PUMPS � / I I w AND RECOMMENDATIONS. HEATERS. PROVIDE WEATHERPROOF I GROCERY rye' R " a 16.603 PROVIDE RECESSED ALARM JUNCTION BOX V ! FREEZER ,..�. . ��... �:. - -_. ._ _ _._ _. .__ ._ . - _. _.. _ .. ,f RECESSED UNCTION BOXES AS ur<w"t�"9._.. 'T <*M""*°"®Kpx�M'"""5 °A + ._,.,, rsrsazsenvase! rrerscc:�swc�ra•�rxrrrresaa�aEswttvr�* i �t .._ _.... ._ _.._,. � � � � � I ; WITH VERTICAL RACEWAY) ( AT +80 WITH )NI REQUIRED. FINAL TERMINATIONS BY Z G I r „ {{ ! AWA ! ! _ r i T Ll I } t r C I wu , g ! F ! , SEP`( I t 4x4 x1-1/2 EXTENSION RING (UNLESS REFRIGERATION CONTRACTOR. '11-1141 i`�fwWa��a,Jwxa.ne+.ut ' w.i..air.� 1,6e,`.w.,wnw �+rz,weuwx� u�w��+rr.ru�'.,w` `tl Wn d 16.720 NOTED OTHERWISE). ' � ~~-••-••� ~• �.��,,:. �, UTILIZE JUNCTION BOXES AND CHASE �-•...--�--3 G 16.715 �F ^�, � # � 16.607 PROVIDE SURFACE MOUNTED ALARM PROVIDED WITH CASE ASSEMBLY FOR �W F.8 +11'-6" } w '� _. .. ." �.� -�''+ r_ � _. � _ .- ' -- _w�`" . -�' '' _. JUNCTION BOX ABOVE CEILING WITHIN THREE IN TALLATION OF DEVICES AND WIRING. W 04Np' air t o zp M .�, wp = O �. y 16.712 FEET OF HOOD FIRE SUPPRESSION SYSTEM FURNISH AND INSTALL DEVICES AS SHOWN ®2! � ,,, a► L1 D3 WPI COMPARTMENT. AND ROUTE WIRING IN CHASE. Z� Wig •d 23 - ��Now- ' .a. J,a : 16.609 INSTALL FURNISHED ALARM JUNCTION BOX 16.724 LEAK DETECTION SYSTEM POWER: PROVIDE z WZ MWN s iexwLriPAItMAFelIt9 °A't!1`. '7S -'ss.w,n:awn.cxxwcwa.'ae 1 -•'..' 'ri.c til' "x'k7.,w:.,...... Q 00'--' 1`�( 'ART 2/2) AT +80", PENETRATE COOLER WALL, AND JUNCTION BOX MOUNTED ON COOLER WALL 1_1 D3 -"-" "`~' ROUTE VERTICAL RACEWAY UP EXTERIOR NEXT TO CONTROL POWER SUPPLY. FINAL WASTE OIL 16.724 2'i„ I SIDE OF COOLER WALL TO STRUCTURE. CONNECTIONS BY OTHERS. COORDINATE z ,. TANK, +48 ,. .' kh1 D3 $ V ' MINIMIZE EXPOSED CONDUIT ROUTED INSIDE LOCATION WITH REFRIGERATION 0 COOLER BOXES. COORDINATE EXACT CONTRACTOR. REFERENCE REFRIGERATION INSECT � �� �� (PARTk 2/2)� I �,�� .. CONTROL, may. LOCATION WITH FIRE ALARM INSTALLER SHEETS FOR LEAK DETECTION SYSTEM ----- -- µ-. z -_ _ PRIOR TO ROUGH-IN. INFORMATION. GFI, +96 f +'� b,+54 � 1 W LL I>r INSECT n.--- 0 CONTROL, a GFI, +96" ri 1GFI, +48" µ.=:µ GROCERY EQUIPMENT SCHEDULE " 48 f NOTE: REFERENCE SPECIFICATIONS FOR MANUFACTURER AND MODEL NUMBERS NOT US7ED IN EQUIPMENT SCHEDULES Q6.513 �, �M 004 f t REF�RIiGERATED AND HOT CASE SCHEDULE �' a MEAT +96 _ -.„; ;f I j I N0. DESCRIPTION MANUFACTURER MODEL N0. VOLT PH AMPS HP VA TERMINATION MTG. HT. NOTES UTILITY [ € Z i 1 D3 s € R121 B HOT DELI SERVICE CASE CUSTOM DELI DILW-8 120/208/3 18.50 WP JUNCTION BOX +12" - I p 27 ! ~-- I R122 HOT DELI SELF-SERVICE MULTI-DECK CUSTOM DELI DILW-4-SS 120/208/3 10.00 WP JUNCTION BOX +12" - W 3 4" i A- J + ; BAKERY EQUIPMENT SCHEDULE o �, J �`f-"-"-" - `w""-'- DESCRIPTION VOLT PH AMPS HP VA TERMINATION MTG. HT. NOTES i- o -16.650..!r - 16:6Og WP �-.._� ' 16.712 N0. t� B005L PAN WASHER 480 3 37.10 WP JUNCTION BOX +12" / „ B007 BREAD SLICER 120/1 1/2 WP GFI DUPLEX NEMA:5-2OR . +20 - B018B LIGHTED BAKERY DISPLAY 120/1 1.50 RECEPTACLE, DUPLEX FLUSH FLOOR - - ' B020 SCANNER 120/1 1.00 GFI DUPLEX, NEMA:5-20R +48" - w B021 PRINTER 120/1 24 GFI DUPLEX, NEMA:5-20R +48 - ; � 1 B024/BO25 SCALE / DEAD SCALE PRINTER 120/1 1.50 GFI DUPLEX, NEMA:5-20R +48" - z B028 AIR COMPRESSOR W/ AIRBRUSH 120/1 1/20 WP GFI DUPLEX, NEMA:5-20R i `I +60", R 0 WATER a `� ' � j h. ' ' ; INSECT CONTROL +12"s _ _ . +I / D004 1 0 , B033 ICING TABLE 208/1 1800 WP RECEPTACLE, NEMA: 6 15R +20" o FILTRATION �' �, _ I _ _ " y� �-- d - `- --w- -- r Y GFI, +58 a,+1 B049 PRE FRIED DONUT PROCESSING SYSTEM , j . � ,_,,,-„Vi,µ•„�� �� � �..,�.,.�..:..;...�-:��.. ��- _-�- � •; 208/1 33.00 RECEPTACLE PIN & SLEEVE #360R6W +20" � t �° t , . -=- r---�•, y ; -- _-r_ _� s -� - ----- -�--- y.� q._..__.,.. B065G RACK OVEN DOUBL ( ) / UNCTION BOX +96" - 3 I s--------�- E GAS 208 3 4.40 J MEAT COOLER 3; w. I I I , kr ,� s a , , ., 1 D007.1 A: CONTROLS 120/1 15.00 JUNCTION BOX +96" - A I - 1I 11 I 16.708 ISSUE BLOCK t---" i MEAT PREP EQUIPMENT SCHEDULE 6 _ - l I E i N0. DESCRIPTION VOLT PH AMPS HIP VA TERMINATION MTG. HT. NOTES t INSECT L � � � . s 4 SECT CONTRO I E GFI, +48 I;W�._ M'; :0 i � ; I! �! 1-J-., _w w M004 SCALE LABELER 120/1 1.50 GFI DUPLEX, NEMA: 5-20R +48 - I`r I L2D3 GFI, +96" _ I I k DELI EQUIPMENT SCHEDULE - --' i ,�° NO. DESCRIPTION VOLT PH AMPS HP VA TERMINATION MTG. HT. NOTES INSECT CO TRO I D004 SCALE LABELER 120 1 1.50 GFI DUPLEX NEMA: 5-20R +48" - " �� �.R; GFI, +96" D00� ; D004.1 SCALE/LABELER 120 j1 1.50 SIMPLEX RECEPT FURNISHED W j CASE d . € a, +54" ?` ' a'� s� F 11 ► D005 WRAPPER 120/1 8.00 GFI DUPLEX, NEMA: 5-20R +48" - t t ' 1'- }'� �l € --- --- D007 SLICER 120/1 1/2 GFI DUPLEX NEMA: 5-20R +48"' 6 x t .� - ° �-- E L2D3 _ , t; BAKERY _- L2D3 I i , ,� D007.1 `� ' DELI ;' '� `; ; i D007.1 SLICER 1 0/1 1/2 DUPLEX RECEPT FURNISHED W/ CASE - - r S 2 E FREEZER µ 31 PREP _ Ii" �- F --�-- E 16'708 D017 MICROWAVE 120/1 13.20 GFI DUPLEX, NEMA: 5-20R +48" - D028 4 VAT FRYER WITH SPREADER CABINET � � {y, A: 10-10 VAT DELI FRYER 4$0/3 31.00 WP JUNCTION BOX +20 4 `s E_ _ __ _t a, +48" �__ D005 , krt » I (PART 1/2) t - ' L2D3 r�' w B: 24 VAT DELI FRYER 480/3 43.00 WP JUNCTION BOX +20 4 {s 16.712 19 d € h 1 I "Z>' I - D059F ROTISSERIE 208/3 24.70 RECEPTACLE, NEMA: 15-50R +40 4 t eI " j GF! +48 _ >� � GFI, + 86 �. PRODUCE EQUIPMENT SCHEDULE 31 _ DESCRIPTION VOLT PH AMPS HP VA TERMINATION MTG. 1 r a F L2D3 I i N0. HT. NOTES 1f J WP " = r D004.1 P004 SCALE/LABELER 120/1 1.50 GFI DUPLEX, NEMA: 5-20R +48" - 16.724 ! a�ss,m"nsm•.+ vv;wa,aonnsxc4•°c°'t�° aatiw�ta:r„�F � L � ,Y ' i+ , z 'MA's ' `'' k"y" '''` 4 i ' P005 WRAPPER 120/1 8.00 GFI DUPLEX, NEMA: 5-20R +48" DRY P005 {,kw ;" �------ F _ r PRODUCE � ,1� TYP OF 2 � iM f K: BAKERY E x 4 jR i { 16.715 `� " 21 a s ______.., PREP " _a +, COOLER SERVICE � CHECKED BY: -; L1 D3 PART. 1` 2f �.- i I � 1�s 3 € , F t DELI , DRAWN BY: TLC r'> .}( / ) DELI ` ' �.. # e1 =` '=.�/ r 16.609 s ' :C 1 It COOLER FILE NAME: GE2 �Tili��� •'^^•N1"'f���..WCbJkYLJi:Lilll.:si..Z.ji"1,. ( f ;. F � „ .k, I�� �� �1'.._..,..."•.r•�v� 4 'h. 'i I€ a aa � D017 PROTO CYCLE: 012712 = y I r ° GFI, +48 r DOCUMENT DATE: 041012 I t �, 12 GFI, +48 H2B . J ; I7--Z7 r ----- Ws4 ,�, e 17 BAKERY wa;�_ f-1 I a . L 3 a, +48" 1 ---- UTILITY ' 16.609 1' �; GFI, +48" INS CT . L1 D m _ ! CON ROL, . .® .IP � 9 B033 I GFI +96" I q. B049 �>< ,� F 16.60'3 `..� _ _ ,� L2D3 11 F� I +60" NOa,+54 " x' 1 L1 D3 PANIC I # 35 + ,1 6 �,,,� a 1 .�______��."w� •.,��� , >�' �.. ,, *° ' I L1 D3 L1 D3 EXTENSION RING I A L2 3 I r-- 1 „ �"' �; NSEC' 16.603 L 9 7 L1� 3 t, B007 +96 _ - -« 16.650 '� a ONTROL '�` i �• I ROUTE LIQUID-TIGHT L1 D3 A �- I _ `' A �I -" FLEXIBLE METAL _ w. +60 NO 1 D3 B021 _�_ .____._� _- - - ,1 16 6 I, +9�' R � #°EXTENSION RING f „ I � �, � -...... _ ,� ...._.,.. t � ,. �q CONDUIT FROM CASE GFI, +48 I M k L1 3 2 B020 .. _ i:"....... ...} H2B -w..,- -- .... _ '` _- _�__�_.� .. ., -; -... -_ ._._�.. �;` , _ r7 l -. .._. -, 8 B ----_-_-_-.---- r �- �-ONNE°E�lOfd-�POIN� - A -"---•-- ,f' 4 " ,, CONCEALED UNDER I ; J + ' t o I INSECT CASES TO JUNCTION I B065G °�, D028B J 2B a +541 16.514 16.609 11 I 1 s 1 PROVIDE INTERLOCK WIRING � �.: 12 � CONTROL , BOX, TYP ��, y ;E ,i GFI, +58 BETWEEN BAKERY OVENS AND ,� --- �E H b ? L ,3 } �,/ . w ._._.,_X024 DELI PREP 16.6071 BAKERY OVEN FANS. REFER hh .�, , ,., _ r, 49 R 121 B ' � - ``�� �ti i 8,025 D028A a g ._.�.. �`�� �' j, r, R122 TO EQUIPMENT SUPPLIERS ' _ e� `' s 16.510 ; ' .,,..d WIRING DIAGRAM FOR I : '� BAKERY TERMINATION POINT AT OVEN `4. - �� ; �.. 3 ,` "� °` 40L .. F GFI +48" `" °.''� F 16.510 27 I UO ri2 � ' M1 15 O'. eT f , 16.607 I .. _ .___-- 25 ; 1�` D004 {s " ,1 to L2D3 TO EH2 h r^ �, t, PROVIDE SPRING � � {� �,.,,. �-INSECT Tr �" . '.� A. r� , �� -:��-_ 23 L2D3 F ./YF FT `�, D059F � t� `� _ � 'PE WOUND INTERVAL 20A, uz CONTROL, t`� ° ',�%% CAKE ! GFI, +48 �21 4 qti ,, '°° 55 7233SPE 120V, 0-30 MINUTE GFI, +58" 16,720 . ,��' ,, DECORATING t _ INSECT �,� L2 `� �� 2D3 NO HOLD TIME SWITCH .r f° .�' L2 `~ Il-- ,., 9 CONTROL o GFI, +96" `� 24 �,��,. L2D3-1 ""w �� OREG Zo �r ,� L2D3 �, �` L2'° '`' cv - .� �.........._ _ ..Q©.28. r.. -- .- _ 3 '` \�2 , L2D SUNT RECEPTACLE x ' P -" �'�� , a PRODUCE .� 16.724 �,' TO BASE OF CASE COOLER `�, 16.712 L1J_U1U � � 06/30/2013 D059F - IBES: ROTISSERIE QUIPM NT PREP SWITCH CLOST I L1 D3 N , { E 17! 19 _. FURNISHED WITH 80188 k �~ ° L2D : : _�..- �_.... _. �ww_________-- --- J A , 1x,659 ____L� �--- ROUTE CONDUIT µ I1 ! _- _ WP I HOOD TYP U N DER GfT� " _.__ _.--_ �---- - = 5 , 16.609 F I II { J J Et I FI, +48" >^-1 1 .66 � y� » I I .._.. ` TYP OF 3 +9b . , 6 � k � •� � F i � I� �, y.j .`�.. _^^�...» :-:. ,Za,...�'�"�'�• y r �:rW^�+-rtie,...,.:. -..,�.�..t.�� � ..._..�....... i ":.":a � ,.�... I f 16.715 I15II-011 I I I POULTRN I` L � � � ENLARGED DELI COLE l t t t a t FREEZER GROCERY € X31 9f t (p � � � � ,, I 16.712 WP s +..I�.. I� M POWER ---------------- _4 L LU Al �.. .. . �.�._.��... .: :.�.._.��._µ ..��...�.�._,�_�.-�. ...�.- .�....., ,.. � .�._-�:_..��.. ...�.�,��. ._�...�.�..�.....� SCHEDULES Y REAR GROCERY POWER PLAN DELI POWER PLAN 2 Q 1/8„ 1,_0„ 1/4» = 1,-0„ i o SHEET: 1 „