Loading...
Specifications Liebert RECE1VF World Headquarters MAR hlf�D O 6 2009 Liebert Corporation 1050 Dearborn Drive, P.O.Box 29186 CITY OF TIGARD Columbus,Ohio 43229 Telephone:614-888-0246 BUILDING DIVISION Facsimile: 614-841-6973 Europe Headquarters Liebert Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco Italy Telephone: 39-049-9719-111 Facsimile: 39-049-5841-257 Hong Kong Headquarters Liebert Hong Kong 23/F Allied Kajima Bldg. 138 Gloucester Road Wanchai Hong Kong Telephone:852-2-572-2201 Facsimile:852-2-831-0114 CHALLENGER SPLIT SYSTEM FAN COIL Job Name TIGARD-TUALATIN SCHOOL DISTRICT Model BUO60E-AAEI Quantity 2 Date Jan 27, 2009 Invoice # Purchaser Hunter Davisson P.O. # Tag # Submitted By Climate & Power Conditioning SL-I 1896 PG 1 Rev 2/9 CHALLENGER ENGINEERING SPECIFICATION SHEET Split System Fan Coil Project Name: TIGARD-TUALATIN SCHOOL DISTRICT Date: Jan 27, 2009 Reference No.:Q01194420 Submitted By: Climate & Power Conditioning Model Number: BUO60E-AAEI Quantity: 2 Condensing Unit Model Number: PFHZ67A-AL3 ELECTRICAL SUPPLY REQUIREMENTS Liebert Room Unit:460 Volt,3 Phase,60 Hertz,28.1 Full Load Amps,35.1 Wire Sizing Amps Condensing Unit:460 Volt,3 Phase,60 Hertz,10.9 Full Load Amps,13.4 Wire Sizing Amps CABINET SECTION • Upflow • Rear Return Unit Color:Z-0430 IBM Off-White NET CAPACITY DATA BTU/hr(kW) • Total:55,900 • Sensible:50,200 72F DB-60F WB 50%RH EVAPORATOR FAN SECTION • Fan Motor 1.5 HP • Air Volume:2,800 CFM • External Static Pressure: .3 Inches of Water HUMIDIFIER SECTION • Infrared with Autoflush Capacity:11.0 lbs/hr(5.0 kg/hr)/4.8 kW REHEAT SECTION • Electric Reheat: 56,200 BTU/hr(15 kW)(Includes Fan Motor) Number of Stages:2 EVAPORATIVE COIL • Coil Face Area:6.67 sq.ft. (.62 sq.m.) • Rows of Coil:4 FILTER SECTION(Disposable Type - Efficiency based on ASHRAE 52-76) • Size:28.5 in.(724 mm)X 29.5 in.(749mm) • Depth:4"(102 mm)30% MICROPROCESSOR • Advanced OPTIONAL EQUIPMENT • Non-Locking Disconnect Switch • Smoke Detector • Condensate Pump • Remote Temp/Hum Sensors cable length:30 ft. MONITORING OPTIONS • Intellislot Web/485 Card w/Adapter LIEBERT SPLIT SYSTEM FAN COIL MODELS STANDARD FEATURES COOLING COIL A-frameN-frame coil design is constructed of copper tubes and aluminum fins.A stainless steel drain pan is provided. FAN Centrifugal type, double width, double inlet, with lifetime lubricating self aligning ball bearings rated at a minimum life of 100,000 hours. The motor operates at 1750 RPM for 60 HZ and 1450 RPM for 50 HZ. The drive package is variable speed, sized for 200% of the fan motor horsepower(the motor is on an adjustable base). The fan draws air over the coil.The fan assembly is located on an isolated fan deck. FILTER Deep pleated with a minimum efficiency rating of 20%(based on ASHRAE standard 52.1) located within the cabinet, and accessible from the front of the unit. CABINET AND FRAME Custom powder painted steel panels with 1" (25.4mm), 1 1/2 lbs. (.68kg) insulation.A hinged control access panel opens to a second front panel which is a protection enclosure for high voltage components. The frame corner posts are constructed of 14 gauge MIG welded steel. The frame is painted with a powder coat finish to protect against corrosion. The unit is totally front accessible including any component removal. HUMIDIFIER High intensity infrared quartz lamps over a stainless steel humidifier pan. An automatic water supply system maintains water level in the pan and a timed flush system greatly reduces mineral precipitation,and is field adjustable to change the cycle time. ELECTRIC REHEAT Electric low watt density 304 stainless steel fin tubular electric reheat elements provide two stages of reheat to control room dry bulb temperature during. ADVANCED MICROPROCESSOR CONTROL (A) The advanced control system includes the following control, monitor and alarm features: Backlit 4x20 LCD, selectable control logic (proportional, PID, intelligent'), programmable analog inputs, component run hour data, selectable humidity control, automatic reheat sequencing, sequential load activation, sequential auto restart, programmed humidifier water cycle, compressor short cycle control, sensor calibration, manual cooling override switches,programmable common alarm, alarm history log,programmable coil flush cycle, unit and control diagnostics, battery backup of unit parameters. *The Intelligent control approximates the actions that a human operator would take to maintain precise,stable control.The control logic uses Artificial Intelligence Techniques including"Fuzzy Logic"and"Expert Systems"methods. DPN000372 REV 7103 REV 0 LIEBERT SPLIT SYSTEM FAN COIL MODELS OPTIONAL FEATURES (Refer to specification sheet for options supplied) CONDENSATE PUMP_Has a minimum capacity of 100 GPH (379 I/h) at 20 ft. head (58 kPa). (Consult factory for 200V or 230V, 50Hz applications) .Pump is complete with integral float switch, pump, motor assembly, and reservoir. (Shipped loose for field installation on Downflow(BF) Units). A dual float switch is also available. _UNIT DISCONNECT SWITCH Two types of switches are available. The"Non-Locking Type"consists of a non-automatic molded case circuit interrupter operational from the outside of the unit. Access to the high voltage electric panel compartment can be obtained with the switch in either the "on" or"off' position. The "Locking Type" is identical except access to the high voltage electric panel compartment can be obtained only with the switch in the"off'position. FIRESTAT Is mounted in the unit with the sensing element in the return air flow. Upon activation the high temperature stat will immediately shut down the entire unit. SMOKE DETECTOR The smoke detector senses the return air,shuts down the unit upon detection, and sends visual and audible alarm. Dry contacts are available for a remote customer alarm. This smoke detector is not intended to function as or replace any room smoke detection system that may be required by local or national codes. FILTERS Four optional filters are available. A 2" 20% prefilter, and 4" 20%, 30%, 40%-45% or 60%-65% main filter may be specified (efficiency based on ASHRAE 52.1). LIQUI-TECT SENSOR Is a solid state water sensor that has no moving parts and is hermetically sealed to keep out dust and dirt. When the sensor detects the presence of moisture the alarm system is activated. REMOTE TEMPERATURE AND HUMIDITY SENSORS Are provided in a vented case for mounting in the room to be conditioned. Includes 30 ft.(9m),60 ft. (18m), 90 ft. (27m), 120 ft. (36m), or 150 ft. (45m)of cable supplied for connecting sensors to unit. FLOORSTAND Is constructed of MIG welded tubular steel and available in heights from 9"to 24" (229mm to 610mm)with vibration isolation pads provided on the adjustable legs. An optional factory supplied turning vane is available for field installation if desired. PLENUM(S) 4 plenums are available for upflow units: 2 way, 3 way, or 4 way discharge; and top duct connection. Each plenum is 18" (457mm)high and construced of steel with 1"(25.4mm), 1 1/2 lb.(.68kg)insulation and is custom painted in unit matching colors. STEAM GENERATING CANISTER HUMIDIFIER This system is housed in a steel enclosure and includes a replaceable canister with integral fill cup, fill and drain valves,and high water indicator. System automatically fills and drains as well as maintains the required water level based on conductivity. HEAVY GAUGE INDUSTRIAL PANELS Are 16 ga. outside panels and heavy duty gaskets which replace the standard 20 ga. panels and gaskets. HOT WATER REHEAT System is factory piped with a two-way solenoid valve and cleanable Y-strainer. Reheat coil is constructed of copper tubes and aluminum fins. REHEAT/HUMIDIFIER LOCKOUT Includes the necessary relays to disable the reheat and humidifier from an external 24 volt signal. SEQUENTIAL AUTO RESTART For units with Standard Microprocessor control,provide an adjustable time delay for unit start-up after a loss of power. SCR ELECTRIC REHEAT Is controlled by the unit microprocessor (only Advanced or Advanced with Graphics) by pulsing the reheat elements for tight temperature control. Not available in 575 volts. HIGH EXTERNAL STATIC BLOWER This blower/motor package is available only on upflow models where external static pressures are up to 2.0 inches/500 Pa(60 Hz)or 1.5 inches/370 Pa (50 Hz). These blowers are rigidly mounted for ducting directly to the blower housing. Heavy gauge panels are recommended with this option. TWO (2)ADDITIONAL REMOTE SHUTDOWN TERMINALS Provides the customer with a total of three locations to remotely shut down the unit. TWO(2)EXTRA COMMON ALARM CONTACTS Provides the customer with a total of three sets of n/o contacts for remote indication of unit alarms. MAIN FAN AUXILIARY SWITCH Provides the unit with one n/o set of contacts to indicate that the motor/unit is on. REMOTE HUMIDIFIER CONTACTS allow the unit's humidity controller to control a humidifier outside the unit. Power to operate the remote humidifier does not come from the Challenger unit. ADVANCED MICROPROCESSOR CONTROL W/GRAPHICS (G) Includes all the features of the Advanced Microprocessor Control except the 4x20 LCD is replaced with a backlit 240x128 dot matrix graphics display. In addition, the Advanced Micoprocessor Control with Graphics includes a larger alarm history file, graphical plots of temperature, humidity, and the analog inputs, bar graph plots of component run history,and a graphical floor plan layout for an optional water detection cable system. INTELLISLOT WEB/485 CARD W/ADAPTER Provides 10/100 baseT Ethernet and RS-485 Modbus network connectivity for unit monitoring and management. The supported management interfaces include: SNMP for Network Management Systems(exp.HP OpenView),web pages,and RS-485 Modbus for Building Management Systems. INTELLISLOT 485 CARD W/ADAPTER Provides RS-485 Modbus network connectivity to Building Management Systems for unit monitoring and management. ENVIRONMENTAL DISCRETE OUTPUTS CARD (ENV-DO) Provides 16 discrete outputs, corresponding to status and major alarm conditions of the unit. DPN000373 REV 5/07 REV 1 CABINET AND FLOOR PLANNING DIMENSIONAL DATA - UPFLOW(BU) MODELS 321/2" UNIT (826mm) - 301/2"--- TOP VIEW (775mm) A ....--A--. STD 3&5T 11 3/4(299mm) ..e= 8112"—.- �+- -- -•--9 5/8" Hi Static 3T 8 5/8(219mm) (216mm) I (244mm) Hi Static 51 11 3/4(299mm) 10 1/4" 4 1 (260;m) J (33+m) ( 1 mm) I 41 mm 30 1/2" (775mm) Standard Piping Location r — 321/2" 12 12" 1 718' (826mm) + (318mm) I (48mm) Projection of Display Bezel 5/8" LL I ( i_ 16mm - T 51/2" 1-\ } (140mm) Standard Electrical Outlet 321/2 "-^"-321/2 ,y Location Through Unit \/ (826mm) Ov mm) (826mm)Ov Overall Overall Dimension Dimension `�-6718 " 7112" (175mm) (191 mm) Filter Access 1 g �_ Standard Electrical Outlet Through Top (457mm) II IIIIIIIIII ��IIIIIIII" II Location Through Plenum INN II Air Discharge Grille N. ��IIIII� IIID��I►� 29 314" 11114000,.\ (756mm) _ Plenum avail a with: ''' '''N N -\ ����` -2,3 or 4 rilles. -i"(25mm) Solid des with a 7/8"(22mm) FRONT& ` du ange on top. SIDES 3/4"(19mm) REAR (2388mm) Blower Outlet with 4 1"(25.4mm)Range 2,12" 29^ (67mm) 76" 7/8"(22.2mm)Flan \ (737mm)\� \ (1930mm) ( } ge for \, T ?4.,,,,.,5 Duct or Plenum Connection UNIT DIMENSIONAL DATA N 1 3/4" REAR VIEW (44mm) jif Return it Louvers (rear return configuration) f UNIT WEIGHT %' 50 HZ 60 HZ MODELS MODELS LBS.(KG) illop BUO35E BUO36E 535(243) BUO59E - BUO60E 545(247) -- Shaded area indicates a recommended BUO40A BUO42A 595(270) clearance of 34"(864mm)be provided . BU065A BU067A 640(291) for component access. Right side BU045W'G BU046WG 640(291) access suggested for"GLYCOOL"units. BUO70WG 8U071WG 710(322) BUO72C BUO68C 545(247) UNIT DIMENSIO DATA BU101C BU102C 555(252) FRON IEW BK058G BK0610 750(341) (front re n configuration) DPN000350 REV 7/03 REV 0 ELECTRICAL FIELD CONNECTIONS 0 1!! �] ---u�rlru� rr .1 Electrical Handy Box" ' ) L] 1 :II7CII`hTlll I 1 h o00 i• i e 1 (factory installed with cover) r l:rr r •Is m 15 • Dom • 7/11 111 11 II �� • x•- ..tea r�rT " �.. I I_ems i I o.0 00 o U U O Terminal Block* (for customer connections) O O 0 0 0 0 0 0 0 0 0 JCii]C MLA ['J[ CO]C'i]L LiCO] C�i]KALIAC]C PALI]CO)C4JC C ]EM O CO]C X I [m]Ct�C CiI Xdri'J VALcai]C®C®Ci] [L C imi]Ni]C�iJ C0i]C�i]CiJCi]CiJCi]CiiJC�i] )(QC�i]C�iJCiDi] C X.1 1) Electric conduit knockouts on top and bottom of electric box. Knockout size 1 3/4"(44.5mm). 2) Three phase connection. Electric service connection terminals when factory disconnect is NOT supplied. 3) Three phase connection. Electric service connection terminals when factory disconnect switch is supplied. 4) Factory installed disconnect switch. (Optional). 5) Three phase electric service not by liebert. 6) Earth ground connection (50/60HZ). Connection terminal for field supplied earth grounding wire. 7) Earth ground bar (50HZ only). Connection terminals with factory ground from each high voltage component for field supplied earth grounding wire. 8) Control and monitoring section of electric box. 9) Remote unit shutdown. Replace existing jumper between terminals 37+38 with normally closed switch having a minimum 75VA, 24VAC rating. Use field supplied Class 1 wiring. Two additional contact pairs available as an option (labeled as 37B&38B, 37C & 38C). Replace existing jumper for appropriate pair as done for 37&38. 10) Special alarm connections. Field supplied 24V. Class 1 wiring for special alarm. Connection made by adding normally open contacts between terminals 24 + 50. Optional additional connections available with Advanced or Advanced with Graphics controls and appropriate optional accessories(connections 51, 55, and 56). 11) SiteScan connection. Terminals 77 (-) and 78 (+) are for connection of a 2 wire, twisted pair, communication cable (available from Liebert or others)to optional SiteScan. 12) Remote condensing unit connection. Field supplied 24V Class 1 wiring to remote condensing unit terminals 1, 2, 3, & 4 from (R2)relay(split system only.) 13) Smoke detector alarm connections. Field supplied 24V. Class 1 wiring to remote alarm circuits. Factory wired contacts from optional smoke detector are#91-comm., #92-NO, and#93-NC. 14) Common alarm connection. Field supplied 24V. Class 1 wiring to common alarm terminals 75 + 76 (and optional 94 + 95, and 96+97),which are factory connected to common alarm relay(R3). 15) Heat rejection connection. Field supplied 24V Class 1 wiring to interlock heat rejection from pigtails 70 + 71 which are factory connected to compressor side switch (self contained units only and to Glycool relay(R5), Glycool units only). 16) Reheat and Humidifier Lockout. Optional emergency power lockout of reheat and/or humidifier: connections provided for remote 24V AC source. 17) Main Fan Auxiliary Switch. Optional main fan auxiliary side switch. Terminals located in field wiring compartment for remote indication that the evaporator fan motor/unit is on. Field to connect 24V maximum. 18) Optional Condensate Alarm (Dual Float Condensate Pump only). Relay terminals located in field wiring compartment for remote indication. *Located inside unit on top for Upflow and on base for Downflow. NOTE: Refer to specification sheet for full load amp. and wire size amp.ratings. DPN000354 REV 7/03 REV 0 PIPING: SPLIT SYSTEM FAN COIL UPFLOW(BU) MODELS rl I - Piping outlet locations through the plenum are IIII the same as the unit. See below for descriptions and connection sizes. Hill I Humidifier Water Supply Line — 1 I— — Hot Water Return 114"OD CU I 518"OD CU(optional) Suction Refrigerant Line — —I I r — Liquid Refrigerant Line #11 Quick Connect on Models BUO36FJBUO35E #6 Quick Connect on Models BUO36FJBUO35E 1 1/8'OD CU on Models BU060E/BU059E I I 1/2'OD CU on Models BUO60E/BUO59E Condensate Pump Line — 1 I— — Hot Water Supply 1/2'OD CU I I I 518"OD CU(optional) Used only if optional condensate pump is ordered. 01 ® Monitoring Panel Zrr Condensate Drain — -' PIPING OUTLET LOCATIONS 3/4"FPT (See Cabinet and Floor Planning Field pitch a min.of 1/8"(3.2mm)per ft.(305mm). Units without Dimensional Data for Piping a condensate pump have a factory-supplied trap in the unit,so a Opening Sizes.) field trap should not be added, Units with a condensate pump will require a field-supplied trap downstream from the pump. The drain line must comply with all applicable codes. (If condensate pump is ordered piping is out top of unit). DPN000375 REV 7/03 REV 0 TYPICAL GENERAL ARRANGEMENT DIAGRAM SPLIT SYSTEM FAN COIL . Hot Gas Condenser Bypass Solenoid High Pressure Coil Valve Switch i,, Scroll / Liquid Injection Compressor Valve Bulb „0,100i >> 112"(12.7mm)NPT J Pressure Relief Valve Suction Line /"I ' Male Quick a r �� -AIR COOLED Connect • , %' I check Vaive`,� Sight Suction Line Coupling' , `�� y� Glass Service Female Quick `��� / Access Connect ead Pressur- Coupling* Control with y Ports A ��� �� Integral Check ee-Temp Hot Gas Valve Receiver External Sensing �� -' Pressure Balancing Tube in Bypass Control Valve Equalizer Bulb Liquid Injection Receiver Heater be /' quid Line Valve Pressure Limiting Condenser Valve / Drier� Drier . Connect Uq id Line Switch �� 14 iq� Solenoid Valve High Pressure )1°' �,' Liquid Line Coupling gh /� Female Quick Switch Connect Scroll j l Expansion Coupling* Compressor 11 • _;�� / Valve ' O i Liquid Injection Hot Gas Bypass'' Valve Bulb` Solenoid Valve J I Evaporator i , j% Water/Glycol Coil Return Suction Line 'Num/ Male Quick /j Line Water/Glycol ❑WATER COOLED Connect Supply ID GLYCOL COOLED Coupling' Fluid Return Line �� from Unit Service Suction Line Access Female Quick �... r;• Ports Connect '0` r 1' V Cou lm ' / �'-`�"'Fluid Supply Tube in External p g m y: Equalizer Sensing \�/` Hot Gas Bypass Shut Off to Unit 4 Condenser Bul/ Liquid Injection •■ Control Valve Valves* r /AO ' �' 2-Way Water // Valve Liquid Line Regulating 1�/ +' Male Quick Valve ,, Drie d'� Connect � 7*, Lquid Line Coupling' Hose Bibs* Female Quick Connect /Expansion Coupling' �� / Valve 0� E vaporator Coil SINGLE CIRCUIT SHOWN FACTORY PIPING = OPTIONAL PIPING Fluid 'Components are not supplied by Uebert but Return are recommended for proper circuit operation from Unit �:, and maintenance. Fluid Supply w ".j. A NOTE:Refer to installation manual for to Unit 3-Way Water field piping guidelines, Regulating Valve D (optional) DPN000374 REV 7/03 REV 0 REMOTE SENSOR BOX DIMENSIONAL DATA 1 9/32',f 1 11/151 (32.5 nn 11 (43 mm) 1 f.416"1,...V1 1 29115" r(85 mm) � 3/16"wd.x 3/8"hi. slots for mounting j .' �' box tovdall {lyp.of 3) 3 13/10' 3 t/4"(988 mm[ (62.6 mm) 7/8"hole with 4-rterubber grommet. 112 m9:32"17 1 mmj rt /� 4 wire shielded cable �,. (see specification of sheet 27/8° for length of cable). 73 mm) Additional 7/8"knocko [ �I 1L8r \1 01 P�-4 pin connector for field on bottom of box for connection to unit alternate cable connection. receptacle. Liebert Room Unit Remote Temp&Humid Sensor Box �� `/ `--Factory installed cable connected to Interface Board Conn. P-16. Receptacle for field connection of cable. Factory supplied,field installed shielded cable.See specification sheet for length. SL-18770 REV 5/85 MONITORING PANEL AND UNIT ALARMS ADVANCED MICROPROCESSOR CONTROL (A) MONITORING /- ®ilia 1010 "A 4gipTO r 1 GENERAL DISPLAY A 4 x 20 backlit LCD which displays all monitoring,control,alarm and diagnostic information. KEYPAD 5 membrane keys for easy movement through the menu-driven control. STANDARD ALARMS TEMPERATURE The high and low temperature thresholds are programmable between 35°F and 90°F (1.6°C and 32.2°C). The alarm indicates excessive high or low return air temperature. HUMIDITY The high and low humidity thresholds are programmable between 15%and 85% R.H. The alarm indicates excessive high or low return air humidity. HUMIDIFIER PROBLEM Indicates excessive high water levels in the humidifier pan or full canister. HIGH HEAD Indicates a head pressure above a factory preset point. Unit is equipped with a factory preset compressor safety cutout switch. (Provided on DX units only.) CHANGE FILTERS Indicates the pressure drop across the filters has exceeded the customer-set level. LOSS OF AIR Indicates a loss of air flow in the unit based on mechanical sensing switches. LOW SUCTION PRESSURE Indicates a suction pressure below the preset cutout point(DX units only). SHORT CYCLE ALARM Indicates the compressor has turned off-on-off at least 10 times in a one hour period. LOSS OF POWER Indicates that a power interruption has occurred. OPTIONAL ALARMS The following alarms are available when the appropriate options are included with the unit. Main Fan Overload Compressor Overload (4)Local Alarms from below Standby Glycol Pump On Special Message 1 Water Under Floor Special Message 2 Smoke Detected Loss of Water Flow Stand-by Unit On FEATURES OF THE MONITOR MONITOR Room conditions, user analog sensors,run hours, alarm history,unit operating status. SET-UP Password protected programming of various time delays and unit configurations. SETPOINT Password protected programming of operational setpoints/alarms. DPN000355 REV 7)03 REV 0 L Liebert_ EMERSON. r1etwerk Power LIEBERT INTELLISLOT® WEB/485 CARD WITH ADAPTER Product Specification/Installation Sheet Description The IntelliSlot Web/485 Card with Adapter providest � 10/100baseT Ethernet Network and Modbus ,r 1 x1K t connectivity for your Emerson Network Power = ..R"g ! ,rr-4•- W 1:04 equipment. N'x i; p:i4-_ las a tirsr Operating status is monitored and alarms are C . h " , `� 4 Jt, communicated via the network, using NMP and/or t g f rs 1 ,�q �911 ra protocol.P protocols and over RS-485 using the Modbus � r �—„ r �, - 3 �€ � �t tea ,! ,� ;_ Additional Features • SNMP vl, v2c with MIB-II support • BootP, DHCP per RFC2131 • HTTP/HTTPS 1.1 • Secure Sockets (SSL) • Telnet Remote firmware updates via HTTP Compatibility With Other Emerson Network Power Products Precision Cooling (With These Controllers) Large UPS • Challenger 3000(LOO, LSM, LAM) Controller Key • Npower • DataMate(MM2, LOB) - Hiross 7200(EMEA) • Deluxe System/3(L10, LSM, LAM) L00: Level 00 • Hiross HiPulse(EMEA) • Himod (LAM) LOB: Level OB • Series 300 • • Hiross Microface IGMnet L10: Level 10 • Series 600/610(Single Module) • Industrial Cooling Series(L10, LSM, LAM) L15: Level 15 Power Management • Mini Mate(LOB) LSM: Standard • Static Transfer Switches:STS, STS2-3 pole, • Mini-Mate2(MM2) Microprocessor ST • Liebert ert FP C • Mini-Mate2 8 Ton (L8T) LAM: Advanced • Precision Power Center • PEC/Atlas(CEMS100/LECS15) Microprocessor . DataWave Overall and Mounting Dimensions 7"(177.8mm) 0.6"(15.3mm) 4-1 2.8" 3.4" r ?Y,ern' 0.8"(20.3mm) h t--- Six holes,each 0 156" diameter 2.4" (61 mm) 1 4" (101.6mm) (10.2mm) U 0.2 (5mm) 4 3.2" (81.3mm) 1 Customer Wiring Input power -.Iv=Ua!= � V x;;r'y> (input to TB3) I grA �• a ' la��� 4 �, c Pin 1(+) ;r q r ' ' Network port Pin 2(-) I a �' ,. , i pt , Pin 3(NC) r Z �^1 ®' for NMS and �' �_ f�'n r Web access to `,# ��'tjI 7, S6' Modbus output 1; � (v 1.. w , a 'Qr for BMS f a " '�'' s , "�,+ 4— DTE serial port ""' 3 % �1111 for configuration (output from TB2) '� ' '' _, .� r,: '� it Gilt (requires null-modem connection) TB1: Pin 1 (+), Pin 2(-) a ' TB2:Pin 1 (+), Pin 2(-) IGMnet or SiteScan Comms from unit(input to TB1 or P1) Refer to user manual for details Specifications AC Inputs 18-24 VAC;50/60 Hz Power DC Inputs 12-36VDC Requirements Power Consumption 6VA maximum Dimensions -W x Dx H: in.(mm) 7 x 4 x 1.5(178 x 102 x 38) Weight Net-oz. (kg) 7(0.2) — Shipping-lb. (kg) 1.3(0.6) Ambient Operating Environment,°F (°C) 32 to 104(0 to 40); 10%to 90%RH (non-condensing) Ambient Storage Temperature, °F(°C) -4 to 140(-20 to 60) Protection SELV Isolated User Connections,Watchdog Timer Circuitry Service Terminal (RS-232) DB9F, DTE Unit Input TB1, 2-Position Terminal Block Communication Communications P1, 20-PIN Vertical Header with Ejection Latches(for some UPS models) Ports Modbus (RS-485) TB2,2-Position Terminal Block Ethernet Communications RJ45 Wiring Specifications Connection Supported Wire Types Maximum Wire Length TB1 RS 422 18-22 AWG Stranded&Shielded; 18 AWG*recommended ( ) Non Plenum-Belden 9461; Plenum-Belden 88761 1000 ft. (300m) TB2 RS 485 18-22 AWG Stranded&Shielded; 18 AWG*recommended ( ) Non Plenum-Belden 9461; Plenum-Belden 88761 3000 ft. (915m) TB3(Power Input) 18-22 AWG Stranded&Shielded; 18 AWG"recommended 20 ft. (6m) Non Plenum-Belden 8770; Plenum-Belden 88770 DB9F Connector DTE Null Modem Cable 50 ft. (15m) RJ45 Connector Standard Category 5 Cable 328 ft. (100m) Liebert Corporation Dearborn Drive Telephone: 1-800-877-9222 C Lieber$. P.O. Box 29186 Facsimile: 1-614-841-6022 EMERSON. Columbus, OH 43229 www.liebert.com Net r'or t Power ©2007 Liebert Corporation ®Liebert and the Liebert logo are registered trademarks of All rights reserved throughout the world.Specifications subject Liebert Corporation.All names referred to are trademarks or to change without notice. registered trademarks of their respective owners. SL-291 05 REV01 06-07 2 $ EMERSON. ELiebert Network Power Keeping guelneep In 9usInnsi LIQUI-TECT® 300 Specifications Point Leak Detection Sensor Liqui-tect 300 Sensor Power requirements 24 VAC,50/60 Hz Description Dimensions 5"x 2.31"x 3.81" W x D x H (127mm x 58.7mm x 96.8mm) The Liqui-tect 300 Weight(assembled) 2.0 lbs(0.9 kg) (LT300)provides a = _ single-point detec- .--'` ", Metal enclosure NEMA 1, IP 30 tion of leaks.The �,`Z ' " , mss, i Environmental Conditions point detection sen- e'" �.�, t` ', Operating sor has two gold '-'4,,.4.1.1: ' 3 „,,,,,p'-..; temperature 50°F to 104°F(10°C to 40°C) plated sensing ,r r .- ”„�j 2 ”' x 10%to 95%relative humidity p g j ate; - '7f , Operating humidity probes to prevent f t T� (non-condensing) y` @ t ' ,� �ri Agency Listings corrosion and to pro- l,,,•, ,,g ,� 2} %'.. i vide accurate read- f 4 kt The LT300 has no agency listings as a standalone device.The �u , w .�, ' �xt sensor is listed as an integral component of a Liebert ings.The LT300 is `° ;- y � environmental unit and therefore shares the environmental the ideal solution for ' ".41 T" i 't ' unit's agency listing. sensing leaks under .1 . raised computer Dimensions-Top, Front & Side Views floors or air condi- ' timing drip pans. TOP VIEW SIDE VIEW nn The LT300 is 0.19" x4 4.50" _0: 2.31" (4.9mm) -\ (114.3mm) 1 (58.7mm) designed to work exclusively with Liebert environ- 14 mental units. (34.9m m) e 1.3 e� I M The LT300 is ideally suited for the following: n Applications FRONT VIEW • Glycol, Chilled Water Cooling i- - • Humidification Feed Water Piping t—► • Unit and Ceiling Auxiliary Drip Pans 3.81" 0 0 0 ;" 1 2.00° g ry p (96.8mm) (50.8mm) • Overhead Piping Troughs 1 — Locations �`'� 5.00° _� I• Large-Scale Network Control Centers 1.50" (127.0mm) "I • Data Centers (38.1 mm) Shipping weight: 2 lbs(0.9 kg) • Server Rooms- Closets Mounting holes: #8 screws • Unattended Remote Shelters Placement on Subfloor Wiring to a Liebert Environmental Unit Under Cooling Support Equipment The LT300 has two wires for connection to a Liebert environmental unit.Note:This sensor should be connected only to a Liebert environmental unit. Figure 1 LT300 to Liebert environmental units rim." Liebert Deluxe S stem/3 To a Liebert Challenger,Himod or environmental unit "�= r_ LT300 Mini-Mate2(8 ton) �� Environmental unit "/ Orange wire • • 24 24V � Leak detection ( ) LT300 'rip _'/--'e zone(directly Brown wire • • 51,55 or 56 beneath unit) Liebert Mini-Mate2 Ordering Information LT300 (1 to5ton) Environmental Product Quantity Description — unit Number Orange wire • • TB1-1 (24V) LT300 I Point Leak Detection Sensor Brown wire • • TB1-2 or TB1-3 Product Specification Sheet page 1 11/02(Rev. 0) PROP FAN CONDENSING MODULES I111I11 IIII a_ - 11 I1 IlIIII IIIIIIIII 11plu „iII II . , , „UII!1gIIIIINI,. .II uIIQ 1111I 11 11 � i� pi.,„ STANDARD FEATURES COMPRESSOR The 11/2 - 8 ton PFH condensing units shall have a compliant scroll compressor with a suction gas cooled motor, vibration isolators, thermal overloads, internal centrifugal oil pump for forced feed lubrication, a maximum operating speed of 3500 RPM @ 60 HZ(2900 @ 50 HZ). The 1 ton PFH condensing unit shall have a reciprocating hermetic compressor. The 8 ton PFH is a dual compressor design with 3 ton and 5 ton compressors. CONDENSER COIL Constructed of copper tubes in a staggered tube pattern. Tubes are expanded into continuous high efficiency aluminum plate type fins. Coil is set in a drain pan for condenser coil washdown. REFRIGERATION SYSTEM Single refrigeration circuit, includes, suction and liquid line quick connect male couplings. The module is precharged with refrigerant and sealed. The 8 ton PFH includes two refrigeration circuits. HOT GAS BYPASS Factory piped hot gas solenoid valve and pressure regulating valve work in conjunction with a thermostatic liquid injection valve. This system allows operation down to zero load on the evaporating (indoor) module. Both circuits on the 8 ton model receive HGBP. FAN ASSEMBLY Consists of propeller type blades, constructed of zinc plated steel or aluminum, secured to the motor shaft by a heavy duty hub with set screws. Direct drive fan motors are provided with rain slingers, lifetime lubricated bearings, and internal overload protection. CABINET AND CHASSIS Designed for outdoor use with either roof or ground level mounting. The condensing module is constructed of galvanized and galvaneal painted steel for corrosion resistance. Both inlet and outlet air grilles are heavy duty steel with a durable P.V.C. coating. Removable exterior panels allow access to the electric panel or refrigeration components for service or maintenance. HEAD PRESSURE CONTROL A Liebert Lee-Temp control system is furnished with each refrigeration circuit and consists of an insulated heated refrigerant receiver with sightglass, pressure relief valve, pressure balancing valve, check valve, and head pressure operated 3-way valve. This system allows operation at ambient conditions as low as-30 °F(-34°C). OPTIONAL FEATURES QUIET LINE Oversized cabinet, low speed 6-pole motor, and Liebert fan blade design combine to achieve the quietest unit available(8 to 10 dB(A)below standard models). Not available on 8 ton PFH. HIGH AMBIENT Oversized condenser coil with high efficiency aluminum plate type fins and increased airflow. Designed for operation at ambient conditions of 105 °F (40 °C) with no reduction in evaporator rated performance. Not available on 8 ton PFC. REV 07/03 DPN000128 REV 0 CABINET AND FLOOR PLANNING DIMENSIONAL DATA PROP FAN CONDENSING MODULES TOP AIR DISCHARGE GUARD HEIGHT TOP AIR DISCHARGE D RIGHT _` �_-`--_--r---:--_---»\' AIR �= INTAKE B LEFT p AIR INTAKE o SHADED AREA rii: ). INDICATES A RECOMMENDED �' CLEARANCE OF 18"(457mm) 2 BE PROVIDED FOR PROPER (51mm) AIR FLOW. 1.5_,.. ma y , ► A_� +r C SHADED AREA INDICATES A RECOMMENDED SHADED AREA CLEARANCE OF 18"(457mm) INDICATES A RECOMMENDED BE PROVIDED FOR PROPER REMOVABLE FRONT PANEL FOR CLEARANCE OF 24'(610mm) AIR FLOW. ACCESS TO HIGH VOLTAGE& BE PROVIDED FOR COMPONENT LOW VOTLAGE CONNECTIONS, ACCESS AND REMOVAL. AND REFRIGERATION COMPONENTS. 361/8 " — (918mm) ` ---4 "TYP, 53 3/16 " (102mm) (1351mm)----- 2 TYP. 112"Bolt-Down Holes (51mm) � (6 places) _ 1 4 23/32 " 1, (120mm) �'� �� 2 " 4.1---_____ �� �` (51 mm) 25 3/32 " 32118 ' (637mm) ---"- 2 (816mm) �.._____ 467132 ' (51mm) (1174mm)_�„, FOOTPRINT DIMENSIONS MODEL NUMBERS DIMENSIONAL DATA IN.(mm) MODULE WEIGHT 60HZ 50HZ A B C D lbs.(kg)net PFH067A-H PFH066A-H ,X PFHZ67A-L_ PFHZ66A-L 53(1343) 36 1/4(918) 38 1/2(978) 5 1/2(140) 488(222) PFH096A-L PFH095A-L 570(259) REV 07/03 DPN000131 REV 0 GENERAL PIPING ARRANGEMENT PROP FAN CONDENSING MODULE Er SINGLE CIRCUIT=1-5 Tons ❑ DUAL CIRCUIT=8 Tons 400" Condenser Coil High Pressure ,0". Switch 1 Compressor' Liquid Injection Valve Bulb i I �r Sot not Bypass Solenoid Valve .... ✓� V/ '`j 114"(6mm)NPT Suction Line Male Quick ■ 1 Connect Coupling %v� ` �P Pressure Relief Valve • r��1 O 3-Way Head , Pressure Hot Gas Bypass Control Valve Sight Glass • ) Control Valve Check Valve .�• 1� Liquid Injection ' . . Valve �f Liquid Line V Solenoid Valve Lee-Temp Receiver ' ✓ Receiver Heater Pressure Limiting %Ili Switch Pressure Balancing Liquid Line Male Quick Valve Connect Coupling •Reciprocating compressor 1 Ton. SINGLE CIRCUIT SHOWN Scroll compressor 1 1/2-8 Tons. REV 07/03 DPN000129 REV 0 PROP FAN CONDENSING UNIT PIPING AND ELECTRICAL CONNECTIONS TOP AIR DISCHARGES *System 2(5 Ton) \ --.... A Electrical Entrance for High Voltage Connection G F Ni. AIIIIIIIPI- Miloit IV -•' . �:1III I III Liquid Line ` Electrical Entrance for Quick Connect Low Voltage Connection (Male Coupling) D _ Suction Line *System 1 (3 Ton) Quick Connect �� E--____, (Male Coupling) 'System 1 and System 2 on 8 Ton only. MODEL NUMBERS ELECTRICAL CONNECTIONS IN,(m) PIPING CONNECTIONS IN.(mini) 60HZ 50HZ A B C D E F G PFH067A-H PFHO66A-H 2 6 8 1/2 4 3/4 7 3/4 8 1/2 x PFHZ67A-L PFHZ66A L (51) (152) (216) (121) (197) (216) PFH096A-L PFH095A-L 11 1/2(292) " REV 07/03 DPN000133 REV O • ELECTRICAL FIELD CONNECTIONS 1 -5 TON PROP FAN CONDENSING MODULE Field supplied unit Field supplied unit disconnect switch. Single or three phase disconnect switch. Single or three phase electric service not provided electric service not provided by Liebert. by Liebert. I __ ,, multi, I �� 0 1111 --,:, ti��IIII I��II IllllII!, li i,1111 I) 44 a (����������� 9 --- -7---- .ilIIIIIIIII''''lli�Illl�;l�l,,i;����,1 _ �II�III� " ;;i Field supplied 24V NEC 1111111 i Field supplied 24V NEC class 2 wiring to 9 dass 2 wiring to evaporator module. evaporator module. Horizontal Air Discharge Models Top Air Discharge Models (5 ton High Ambient or 5 ton Quiet-Line) Electric service connection Factory wired to components on to contactor or terminal block. electric panel. 0 Single or three phase electric service not provided by Liebert. or% �/ m IV High voltage electric power 4 1 !... :. ..: supply entrance. Low voltage electric power supply entrance. Earth ground connection terminal for field wiring. Heat rejection connection. Field supplied 24V NEC class 2 wiring. Wire connections from evaporator module: 1 24V GND 2 24V Supply 3 High Pressure Alarm 4 Hot Gas Bypass Connection (only on units with hot gas bypass. If no hot gas bypass,connection is provided in the evaporator module. Connect wire 4 with wire 2 to the 24V supply). NOTE: Refer to specification sheet for full load amp. and wire size amp. ratings REV 07/03 DPN000134 REV O EMERSON. L Liebert° (EeSZwork Power M.,Pi,a e.,.,,, • �., .<„' AC4 Product Specification/Installation Sheet Description - The Liebert AC4 is ideal for coordinated control of systems with ilk: redundant equipment, such as multiple environmental units or ,01=17.-57', pumps. When the AC4 controller detects an alarm in an operating device, the AC4 enables a standby device and controls the device in alarm as configured, either leaving that devicert� _5 operating or disabling it. " ___ — The AC4 controller can also balance usage of devices by rotating units through Operating and Standby modes according to a user-defined schedule. This helps keep redundant equipment operating efficiently and only when needed. The AC4 can perform routine testing of standby devices and alert personnel if a standby device fails an operating test and requires attention. Another capability of the AC4 is monitoring the Features and Benefits status of connected devices and keeping personnel apprised through local alarming. ' Custom configuration for specific applications • The AC4 controller can interface with anything Alarm and Event logs with time and date that closes an electrical contact. To improve stamp process efficiency and troubleshooting, the ' Backup and download configuration files controller tracks data in two types of logs: • User interface for configuration and alarm and event. The AC4 has a local LCD monitoring via local LCD or RS232 port interface and an RS232 interface. • On-board audible alarm • When an alarm condition arises, the AC4 • Configuration data and operating program displays alarm information, sounds an audible permanently stored in nonvolatile alarm, changes the state of the common alarm Electrically Erasable Programmable Read relay and turns connected devices on or off Only Memory (EEPROM) for protection according to user configuration. against power loss For other applications, contact your local • Real-time clock Liebert representative or call 1-800-222-5877. • Status LEDs for verification and diagnostics AC4 Components and Key Features Audible horn Audible horn Power On/Off switch jumper Common Alarm connectors 24VAC power connector —® no.:,:„..,- O Digital output status LEDs csq �� d )t ;° i Manual Override Switch LCD contrast c-t— r . :. (outputs) adjustment ? 'fi a o Digital output connectors LCD connector ' =f� ,• . II Q:i-� - T'31 V :.C� F �. : .c Status LEDs DIP switch 1 �'L ' ■i {4.,,.=:._,::-. e [_] S- r e Digital output loss-of-power o ' � : jumper _Ilan■'II'1i• ,., A=��c- _ Digital input connectors • Serial interface connector '' (RS232/E1A574) �,..•f °;__;__, Digital input status LEDs 1 Hardware and Components The AC4 comes standard with an enclosure, a controller board and a liquid crystal display (LCD). AC4 enclosure-Internal features Back of LCD 0000 =y- 7---: ®- . Controller Board n,•:w®Y:_ of E.' ••,--1 e '''°Q ,_ Q. c (C?OC)0 O OO-- Knockouts and access slots Ground wire for LCD / L' (top and bottom) Enclosure Controller Board The AC4 enclosure features a key lock for added The controller board supports a total of 10 security.The enclosure is made of metal to points (four digital inputs, four digital outputs accommodate secure conduit fittings and and two Common Alarm outputs). protect components against environmental Point Type Point Count debris. Digital input 4 AC4 enclosure-External features Digital output 4 Common Alarm output 2 - 0000 .-� 0000 The digital inputs are dry contacts.The digital outputs and Common Alarm outputs are Knockouts and - Key Form C contact relays. The Common Alarm access slots lock on top and ( ' .• . output is one output with two sets of contacts. bottom The point terminations are made using remov- • LCD for able terminal blocks. This allows for easier configuration access to the terminators, streamlining the pro- _____ ana operation cess of connecting external devices to the AC4. • The enclosure is designed for easy wire The controller board is a microprocessor-based routing and terminations.Access slots for platform for program execution. communication cables and network wires are The firmware, including the operating system located on both the top and bottom of the and user-defined data, is stored in nonvolatile enclosure. flash read-only memory. Flash ROM may be • The enclosure is 2-3/4" deep, allowing for easily upgraded at the job site, simplifying the recess mounting in a wall.The enclosure may Process of installing new firmware as it also be flush-mounted. becomes available. • The enclosure houses the LCD and the An RS232 operator terminal port is included controller board. with each controller board for operator devices such as a simple CRT terminal or laptop PC. Keypad Display The keypad display is a user interface mounted on the enclosure door of the AC4. The display provides for complete monitoring and configuration of the panel and is password-protected. '"`°"` �`"'"" - . ,,„ z� r. • . Keypad The keypad display provides the ability for the Y.�.hy, rti �, ' - . display AC4 to operate as a complete standalone < panel. (Esc ,* I + " �'I', • 2 Dimensions 14.25" 14-7361.95mn7)-1 I r _ 2.85" I I 12" 000 t®®® (72.39mm) omm® (304.8mm) Top/bottom view � © 1 Front view Wiring Specifications Connection Supported Wire Type Maximum Wire Length Rating 18-22 AWG Stranded&Unshielded Digital 18 AWG*(recommended) Dry Contact Input Non Plenum-Belden 9740 750 ft. (225m) (24VDC, Plenum-Belden 89740 10 mA) 18 AWG* 20 AWG 22 AWG 18-22 AWG Stranded&Unshielded (recommended) Digital 18 AWG*(recommended) 24VAC Output Non Plenum-Belden 9740 @3A 50 ft.(15m) @3A 40 ft. (12m) @3A 25 ft. (7m) @3A Plenum-Belden 89740 @2A 100 ft. (30m) @2A 60 ft. (18m) @2A 35 ft. (10m) @1A 200 ft. (60m) @1A 100 ft. (30m) @1A 75 ft. (23m) 18 AWG* 20 AWG 22 AWG 18-22 AWG Stranded&Unshielded (recommended) Common n 18 AWG*(recommended) 24VAC • Output Non Plenum-Belden 9740 @3A 50 ft. (15m) @3A 40 ft. (12m) @3A 25 ft. (7m) @3A Plenum-Belden 89740 @2A 100 ft. (30m) @2A 60 ft.(18m) @2A 35 ft. (10m) @1A 200 ft. (60m) @1A 100 ft. (30m) @1A 75 ft. (23m) Communication Null Modem Cable 50 ft. (15m) N/A RS232 18-22 AWG Stranded &Shielded 24VAC Power 18 AWG*(recommended) 24VAC Connection Non Plenum-Belden 8770 150 ft. (45m) @1.3A (TB7) Plenum-Belden 88770 @ *Recommended 3 AC4 Specifications Power Requirements 24VAC±10%of nominal Typical Configuration . 50/60 Hz, 1.3A,30VA 14-1/4 x 2-3/4 x 12 Dimensions W x D x H, in.(mm) o; -®"W= 0 ' (361.95 x 69.85 x 304.8) —®= Weight(Assembled) 7.68 lbs(3.48 kg) a t Enclosure Type NEMA 1 5��i w __ Liquid Crystal Display (LCD) Four line, 20 character, backlit �r y n, ,•s� °lit i f Mounting Surface Building Wall or Structural Member 4 it—,..„.„.„...031-..- Ambient Operating 32°F to 104°F(0°C to 40°C) r Environment 0% RH to 95% RH (non-condensing) r•``■11�` 1i a g5t , `- Processor Specifics --gym _ _ Model Motorola XC68HC812A4 Clock speed 16MHz Total RAM 32Kb Total FLASH 4M RS232 Total EEPROM 4K A/D Resolution (Analog IN) 12 Bit 7- -DEVICES CONNECTED Clock Type Real-Time Clock TO INPUTS&OUTPUTS Clock battery backup type Lithium Cell (non-replaceable) Zone 1 Devices Clock battery life 7 years,constant,no power Device 1 Device 2 Communications =1 P.'. ._ i:!i Local Communications RS232 ., Agency Listings . UL UL3121 �� „. Liebert Liebert • CSA C22.2 NO. 1010 Challenger Challenger CE Yes - 3000 3000 FCC Compliance CFR 47 Part 15 Zone 2 Devices • Device 3 Device 4 Inputs &Outputs (Quantity) Digital Inputs(4) Dry Contact Closure 24VDC, 10 mA Digital Outputs(4) 24VAC, 3A Liebert Liebert Common Alarm Outputs(2) 24VAC, 3A \Himod Himod____} Ordering Information Quantity Part# Description AC4 AC4 controller board in enclosure 201258P1 RS232 configuration cable TM115 Transformer Module 115VAC with two 24VAC outputs(40VA each)and 115VAC receptacle TM230 i Transformer Module 230VAC with two 24VAC outputs(40VA each) n ��• Liebert Corporation 7 1050 Dearborn Drive Telephone: 1-800-877-9222 EMERSON. P.O. Box 29186 Facsimile: 1-614-841-6022 M Liebert° Network Power Columbus,OH 43229 www.liebert.com •..,., �.,.. , , �.,i.. r ©2004 Liebert Corporation ®Liebert and the Liebert logo are registered trademarks of All rights reserved throughout the world.Specifications subject Liebert Corporation. All names referred to are trademarks or to change without notice. registered trademarks of their respective owners. SL-31205(11/04)Rev. 0 4