Loading...
PFI2014-00075 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PFI2014-00075 Date Issued: 09/23/2014 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: SEG1629 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Frontier Project Description: On SW McDonald St.from Pacific Hwy.to SW 102nd Ave., place conduits, hand holes, one manhole, poles, and down guys and anchors to relocate Frontier facilities to accommodate an ODOT street improvement project. SEG 1629, 1632, 1636, 1638. Owner: FEES Description Date Amount PHONE: Contractor: ROBINSON BROTHERS CONSTRUCTION 6150 NE 137TH AVE. VANCOUVER,WA PHONE: 503-559-2161 FAX: Applicant: BOB PLANT 4155 SW CEDAR HILLS BLVD. BEAVERTON, OR 97005 PHONE: 503-644-7153 Total $0.00 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: O tcolz�iO oo Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12014-00075 Type: Condition Name: Status: Severity: ROW 01-CUSTOM CONDITION Not Met Notice Resubmit TTC plan at least 48 hours before beginning work that provides for a flagger to direct left turns from SW McDonald to SW 105th Ave. Works hours are restricted to 9 p.m.to 5 a.m.or as directed by ODOT. ROW 02-PERMIT&PLAN REQ ON SITE Not Met Notice A copy of the permit and all attachments, and a copy of the approved construction plan and all amendments shall be available at the work area. All work shall conform to the permit terms,conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's Standards and Specifications and to these General Conditions. Changes to any of the aforesaid must be approved by the City, in advance of work performance. ROW 04-TRAF CTRL-CONTR RESPON FOR Not Met Notice Traffic control shall be provided for by the contractor in accordance with the City's standard specification and, also, in accordance with a City(job specific)approved traffic control plan.A copy of the approved traffic control plan shall be available at the work area. ROW 03-TRAF CTRL-SPECIF(CITY) Not Met Notice The City's standard specification for traffic control is"Manual on Uniform Traffic Control Devices for Streets and Highways", U.S. Dept.of Transportation, F.H.A., 1988 Ed. ROW 05-TRAF CTRL-ROAD CLOSURE Not Met Notice Public roadway shall not be closed to traffic,at any time,without having first obtained written approval from the City Engineer.The permit holder is responsible for provision of timely notification of traffic flow disruptions to area wide Emergency Services(Tigard Police Dept.,Tualatin Fire&Rescue)and to Tri-Met and Tigard School District. ROW 06-TRAF CTRL-ADVANCE WARNING Not Met Notice Advance warning of imminent traffic disruption shall be provided to the general motoring public by placement of an advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. ROW 07-TRAF CTRL-PRIV PROP ACCESS Not Met Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service and if not, shall be cause for work stoppage until effective access is established. ROW 08-TRAF CTRL-DEVICES IN PLACE Not Met Notice Traffic control devices, flagpersons,etc.,shall be in place prior to initiation of construction work and shall be effectively maintained. ROW 09-TRAF/NOISE CTRL-WORK HRS Not Met Notice No work will be permitted during the hours of darkness, nor between 9:00 p.m.to 7:00 a.m. Monday through Friday, nor between 9:00 p.m.to 8:00 a.m. Saturday, nor between 9:00 p.m.to 9:00 a.m. Sunday. ROW 16-REPAIRS-LIKE MATERIALS REQ Not Met Notice Property disturbed by construction activity shall be seeded with a standard grass mix;shrubs,flowers, barkdust,existing signs, pavement markings, mailboxes,etc.,shall be reestablished, reinstalled or replaced,with like kind and material. ROW 10-TRAF CTRL-MIN LANE WIDTH Not Met Notice Minimum travel lane width shall be eleven(11)feet; pedestrian travel shall also be provided for. ROW 11-TRAF CTRL-CITY CAN MODIFY Not Met Notice The City reserves the right to add to or modify traffic control requirements as may be necessary to effectively control traffic and to assure public safety. ROW 12-INSP 24 HR NOTICE REQUIRED Not Met Notice The permit holder or his contractor shall notify the City's inspector Kenny Fisher at 503-816-6146 or email at kenny@tigard-or.gov,twenty-four(24)hours prior to commencing work,twenty-four(24)hours prior to any staged inspection,and after completing work covered by the permit. ROW 17-DRAINAGE CONTROL REQ Not Met Notice Effective drainage control is required. Drainage shall be controlled within the work site and shall be so routed that adjacent private property, public property and the receiving system is not adversely impacted.The City may,at any time,order corrective action and stoppage of work to accomplish effective drainage control. ROW 24-TESTS/REPTS TO VALIDT CLMS Not Met Notice The City's Inspector may, at their discretion, require provision of tests and or reports from the permit holder, permit holder's engineer or contractor to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the permit holder's expense. ROW 13-HAZARDS-CERT OF INS Not Met Notice Maintenance of the work area and approach roads is the responsibility of the permit holder.The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards.A copy of the permit holders Certificate of Insurance shall be available at the work area. ROW 14-DEBRIS-MATERIALS Not Met Notice The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit.The City may at any time order immediate cleanup and stoppage of work to accomplish cleanup. ROW 18-UTILITIES PRELOCATION REQ Not Met Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0010 through OAR 952-001-0080. Copies of the rules may be obtained from the Center by calling(503)232-1987. If you have questions about the rules,contact the Center.NOTE: Damage to utilities shall be corrected at the permit holders expense. ROW 15-EROSION CTRL REQ Not Met Notice Effective erosion control is required. Erosion control devices must be installed and maintained meeting D.E.Q. requirements.The City may at any time order corrective action and stoppage of work to accomplish effective erosion control. ROW 19-UTILITY LOCATIONAL CONFLICT Not Met Notice Contractor must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the permit holders expense. Changes must be approved by the City in advance of work performance. Contractor shall coordinate the work with affected utility agencies. ROW 20-TRENCH-PATCH/SAFETY/LBILITY Not Met Notice A temporary hard-surface patch(Cold mix A.C. or Hot mix A.C. base paving) shall be placed on trenches within roadways at the end of each day's work. No trench,on site or off site,shall be left at any time in an unsafe condition.The permit holder is responsible for and is liable for hazards or damage resulting from the work. ROW 21-REPAIRS REQ-INSPTR OPINION Not Met Notice Work provided for under the permit shall include repair of existing facilities(roads,ditches,etc.)as may be necessary, in the City Inspectors opinion,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.Corrective work shall be done at the permit holders expense. ROW 22-AS-BUILT/ENGR CERTIF REQ Not Met Notice At the end of each year,or an a mutually agreeable yearly date, any entity making changes to its facilities in the public right-of-way shall submit complete"as-built"drawings showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineers certification of installation compliance(form attached). ROW 23-DAILY INSP REPORTS REQ Not Met Notice The permit holders Engineer/Inspector shall submit daily inspection reports, on a weekly basis,to the City's Inspector. (see Developer-Engineer Agreement note#5). ROW 29-ESMT/RT OF ENTRY-RESPON Not Met Notice It is the sole responsibility of the permit holder to provide for proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry,or properly executed easements,shall be provided to the City.The City shall in no way be construed to be liable for the permit holder's failure to obtain or provide for proof of right-of-entry or easements. ROW 26-MONUMENT PROTECTION REQ Not Met Notice Existing monuments, property corners,and survey markers shall be protected. Replacement shall be at the permit holders expense. ROW 27-PROB SOLVING-RESPON PARTY Not Met Notice The permit holder shall provide to the City Inspector, in writing,the names and 24-hour emergency telephone number of two (2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of an emergency.The permit holder shall notify the City Inspector, in writing, of any/all assignment changes. ROW 25-RELEASE-WAIVER REQ Not Met Notice The permit holder shall provide a copy of a properly executed Release&Waiver document to the City for each ownership disturbed by construction activity, as evidence of disturbance resolution and owner satisfaction. ROW 28-CONSTR SAFETY-RESPON PARTY Not Met Notice The permit holder shall cause his contractor to provide to the City Inspector, in writing,the name and 24 hr emergency telephone number of a designated"Competent Person"responsible for construction safety as per OR-OSHA, Chap.437, Div. 3 Construction, Subdivision P-Excavations.The contractor shall notify the City Inspector of any/all assignment changes. RECEIVED City of Tigard SEP 10 2014 CITY OF TIGARD • Public Facility Improvement PLANNING/ENGINEERING (PFI) Permit t t ; General Information: FOR STAFF USE ONLY Property Address/Location(s): SW MCDONALD ST Engineering Case No.--PF`2Ol �� FROM HWY99 TO SW 102ND AVE �tk _ O Fee: Receipt No.: *Applicant's Name: FRONTIER COMMUNICATIONS Date: 91 L Address: 4155 SW CEDAR HILLS BLVD Application Accepted:__q By: City/State: BEAVERTON, OREGON Zip: 97005-2016 Primary Contact. BOB PLANT REQUIRED SUBMITTAL Phone: 503-644-7153 Fax: 503-643-0977 INFORMATION robert . lant@f tr..com Professional Engineered Plans are required for: ROBINSON BROTHERS CONSTRUCTION Street WideningContractor's Name: • Subdivision Infrastructure CCB# 073387-18 Expiration: 01/02/2016 • Main utility fine extension: Address: 6150 NE 137TH AVE 0 Storm Drain,Sanitary—Tigard 0 Water—Tigard Water Service Area City/State: VANCOUVER, WASHINGTON "Zip: 98682 (includes Durham,King Cit)and a 503-559-2161 portion of unincorporated WashingtonPhone: Fax: Count)) JIM ZERFING *'Note:See Engineered Plan Plans By: Submittal Checklist attached. Address; 4155 SW CEDAR HILLS BLVD For all other work:Submit scaled sketch of the City/State. BEAVERTON, OREGON Gip: 97005-2016 work to bedone.(secattachednrinimtunsketch Phone: 503-502-5413 Fax: requirements and provided sketch area). Upi ttcd a/za/rrl 3 I:\CURPL\1\hucrs\1anti Use Applications\Public F.iaGry PLACE CONDUITS HAND HOLES I rnprnrcmcn W,,c., Description of work: � , ONE MANHOLE, POLES, AND DOWN GUYS AND ANCHORS TO RELOCATE FRONTIER FACILITIES TO ACCOMODATE AN ODOT STREET IMPROVEMENT PROJECT. SEE ATTACHED WO 51351-5105862 Estimated value of work(within the public right-of-way): $ 3 0 0, 0 0 0 Is work related to a LAND-USE DECISION? YES F—] NO a If so,please specify(MLP,SDR,SUB,etc.) case #: Is the work related to a BUILDING PERMIT? YES F] NO n If so,please specify(BUILDING PERMIT) case #: City of Tigard 13125 SW Hall Blvd.,Tigard,OR 97223 1 503-718-2464 1 www.dgard-or.gov I Page 1 of S t r APPLICANTS: To consider an application complete,you will need to submit ALL of the REQUIRED SUBMITTAL ELEMENTS as described on the front of this application in the"Required Submittal Elements"box. NOTE: Person specified as"Applicant"shall be designated"Pert»ittee"and shall provide financial assurance for work. *When the owner and the applicant are different people,the applicant mast be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)mast sign this application in the space provided on the back of this form or submit a written authorization with this application (Detailed Suhminal Requirement Information sheets can be obtained,upon request,for all types of Lind Use Applications.) BY SIGNING BELOW,THE APPLICANT(S)SHALL CERTIFY THAT: a The above request does not violate any deed restrictions that may be attached to or*mposcd upon the subject propcM. • If the application is granted,the applicant will exercise the rights granted in accordance with the tens and subject to all the conditions and lirnitations of the approval. • All of the above statements and the statements in the plot plan, attachments, and exhibits transmitted hcrewith, are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements are false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denting die application. SIGNATURES of c#&h owner of the subject property. DATED this V day of S,! /3 to okl c'/L ,20 1 L' f App cant/Attu ed Agent's Signature Owner's Signature Owner's Signature Owner's Signature City of'rigard 1 13125 SW Hall Blvd.,Tigard,OR 97223 1 503-718-2464 1 www.dgird-or.gov I Page 2 of 5 Knowledgeable&Dedicated Service Company: / Notes: Notify Fire/EMS,EPD and LTD 48hrs / iThe preparer of this traffic control plan Frontier ROM / 1. Maintain ped.access to before beginning work makes no representation as to its'being approved for implementation.Approval and through crosswalks must come from the Traffic Engineer or 2. Maintain Min.10'lanes / other Public Official having statutory 3. Maintain local access CONTACT:Robert Plant I enforcement authority in the jurisdiction. 4. Notify Transit authority at 503-664-7153 / MUTCD 2009 6A-01(10) least 48 hrs.of bus stop / closure / 5. Traffic control plan and all LOCATION: Hwy 99&McDonald -5 / / devices shall comply with Tigard OR / MUTCD and ATSSA DATE: JOB# I 6. Adjust to field conditions 9/10/14 5105862 w4-2 / fi/ to — K&D SERVICES OF OREGON, INC � � / PHONE:503-723-7287 � • � j / NOT TO SCAL FAX:503-723-8750 Li DRAWN BY: 7b / G / ALAN WARD • O ROM TCS#04456 wzo-? / R3/2 woRK E wz0-4 w20 _ _ �W Gaacde St _ _ p _ f• t ROrp vrouc MPH W20-1 w11-1 w1-° W20-7b . it 35 / 1051h ,� Legend INVENTORY: 7 / 't� 5-Road Work Ahead f -'a i w20-7a w20-7a ro "�""r / •ro ° Ro.oED % be prepared to stop W20-7b 4-Bikes On Roadway "°' WORK / E <* road work ahead W20-1 2-Right Lane Closed W20-� / wzoab w20-1 11 road narrows W4-2 2-Transition Left right lane closed ahead W20-5 1-Lane Shift Left , n® Work Area 1-No Left Turn / I L Cone O ! 6-Be Prepared To Stop / ." 4.2 Barrel 5-Flagger Ahead , 1n flagger flagger ® no left turn 113-2 5 Flaggersm— , � Barrier 2-Arrow Boards / I' Arrowboard(Single) 2-Type 3 Barricades / ' i Sign Stand 12-Barrels / ' wog° / � w11-1 w>.>.-1 40-Cones / <S> reverse curve W1-4 aoln.laS a'8�f.. TGRD-HWY99 AT GAARDE/MCDONALD ST - STREET IMPROVEMENT FRONTIER CONDUIT FRONTIER CONTACTS ODOT/TIGARD TO WIDEN HWY 99 FOR RIGHT TURN LANE. INSPECTOR:BILL LAFLUER 503-936-2035 PGE TO SET NEW POLE BEHIND NEW SIDEWALK. FRONTIER TO PLACE 3'X5'20K SIDEWALK HAND HOLE BY OLD POLE AND OVER EXISTING CONDUITS TO THE EAST. ENGINEERING:BOB PLANT 503-644-7153 FRONTIER TO PLACE 2-4"PVC CONDUITS FROM NEW PGE POLE TO NEW HAND HOLE. ATCO ENGINEERING-JIM ZERFING 503-502-5413 FRONTIER TO RELOCATE 4-WAY DIRECT BURIED CONDUIT SYSTEM TO SOUTH TO MAKE ROOM FOR STORM MANHOLES. A 4'X4'MANHOLE TO BE 4'X4'MANHOLE TO BE PLACED BY ODOT PLACED BY ODOT 44"PVC AT STA.147+01.60 33.23'LT AT STA.145+59.80 33.19'LT _ 2-4"PVC EXISTING HWY99-PACIFIC HWY EXISTING 6'BIKE }I/� 13'TURN LANE CURB ------ � ^ �,� 8'SIDEWALK �, EXPOS 4 "DIRECT BURIED CONDUI AND MOVE TO SOUTH EXPOSE 44"DIRECT BURIED \ TO MAKE OM FOR MANHOLE CONDUITS AND MOVE TO SOUTH \ A TO MAKE ROOM FOR MANHOLE \ 2.4-PVC EXISTING SEE CONDUIT WP2 400 FEET TO MCDONALD ST 4'X4'MANHOLE TO BE A PLACED BY ODOT BRING EXISTING 44"PVC 4 AT STA.148+27.64 33.53'LT CONDUITS INTO HH' EXISTING HWY99-PACIFIC HWY 6'BIKE EXISTING POLE__ TO BE REMOVED 13'TURN LANE FTR TO PLACE 2 4'PVC FROM POLE TO HH-20 FT CURB - --- - - PGE TO SET NEW POLE 8'SIDEWALK FTR TO PLACE PLACE DOWNGUY TO PG OR 3X5'20K HAND HOLE 1�"�C EXPOSE 4�"DIRECT BURIED T1O-n-h er, EXISTING CONDUITS AND MOVE TO SOUTH A Fl r,,ti,,, TO MAKE ROOM FOR MANHOLE TGRD-HWY99 AND GAARDE/ WP 10 OF 15 MCDONALD STREET IMPROVEMENT PROJECT C O AREA TIGARD CONDUIT WP 1 OF 6 NUMBER:5105862 EXCH CODE 51351 ALL NOTES ON CONDUIT WORK PRINT 6 APPLY TO THIS WORK PRINT 5T__ATE: ENGR. BDe PuxT NTr WASHINGTON 7.74201! PHONE: 503474-7153 FILE. 51 351-51 05862 TAX DISTRICT jDWG 10 OF 15 TWNSHP: RNG: SEC TGRD-HWY99 AT GAARDE/MCDONALD ST - STREET IMPROVEMENT FRONTIER CONDUIT Lo o N c+7 M C7 C7 C7 T SIDEWALK 5'BIKE LANE 11'TRAFFIC AND TURN LANE 11'TURN LANE c*) a 14'TURN LANE H Z) 2 EXISTING 4"PVC ❑ FTR POLE#36410 TO BE REMOVED 11'TRAFFIC LANE Z O U w 11'TRAFFIC LANE w PLACE 1-466 INTERCEPT MANHOLE U) 5'BIKE LANE PLACE 1-4"PVC 35' T SIDEWALK PLACE PED OVER BSW PGE TO PLACE NEW POLE PGE#4603 PLACE 1-4"PVC 70 PLACE 2-4"PVC 10' 255' ALL NOTES ON CONDUIT WORK PRINT 6 APPLY TO THIS WORK PRINT enfi er FRONTIER CONTACTS INSPECTOR:BILL LAFLUER 503-936-2035 WP 11 OF 15 GRD-HWY99 AT GAARDE/MCDONAL ENGINEERING:BOB PLANT 503-644-7153 CONDUIT WP 2 OF 6 STREET IMPROVEMENT ATCO ENGINEERING-JIM ZERFING 503-502-5413 PROJECT CO AREAODE:5ARD 51351-5105862 NUMBER:5105862 EXCH CODE 51351 DRAWN DATE: ENGR. BOB PLANT :WAHINGTON 7-7-201 PHONE: 503444-7153 FILE: SCALE:1-50 TAX DISTRICT: DWG 11 OF 15 TWNSHP: RNG: SEC: TGRD-HWY99 AT GAARDE/MCDONALD ST - STREET IMPROVEMENT FRONTIER CONDUIT ALL NOTES ON CONDUIT WORK PRINT 6 APPLY TO THIS WORK PRINT o 0 v li T SIDEWALK 5'BIKE LANE N d 11'TRAFFIC AND TURN LANE �f a 11'TURN LANE 5 Z z O 14'TURN LANE Z CU SW MCDONALD ST O w U w -- w 11'TRAFFIC LANE �� cf) 11'TRAFFIC LANE - - 5'BIKE LANE 7'SIDEWALK PLACE 3'X520�HH PLACE 2-4"PVC PLACE 1-4"PVC PLACE 2-4"PVC (255') 15' 240' FRONTIER CONTACTS SW 105TH AVE flunfier INSPECTOR:BILL LAFLUER 503-936-2035 WP 12 OF 15 GRD-HWY99 AT GAARDE/MCDONAL ENGINEERING:BOB PLANT 503-644-7153 CONDUIT WP 3 OF 6 STREET IMPROVEMENT PROJECT C.O.MEA TIOMD ATCO ENGINEERING-JIM ZERFING 503-502-5413 51351-5105862 NUMBER:5105862 EXCH,CODE:51351 DRAWN DATE: ENGft: BOB PLM7 :WAHINGTON ,!,Al PHONE: 50.1844-7153 FILE: SCALE:1.50 TAX DISTRICT: DWG 12 OF 15 TWNSHP: RNG I SEC. TGRD-HWY99 AT GAARDE/MCDONALD ST - STREET IMPROVEMENT FRONTIER CONDUIT o 1n FTR TO PLACE NEW POLE FTR TO PLACE ANCHOR 15 ch SW MCDONALD ST — - 11'TRAFFIC LANE D Z O C) 11'TRAFFIC LANE LLI PLACE 24"PVC W 50' U) 5'BIKE LANE 7'SIDEWALK _----- PLACE 3'X5'20K HH PLACE 24"PVC (240') ALL NOTES ON WORK PRINT 6 APPLY TO THIS WORK PRINT flo-7n-her FRONTIER CONTACTS WP 13 OF 15 GRD-HWY99 AT GAA /MCDONAL INSPECTOR:BILL LAFLUER 503-936-2035 STREET IMPROVEMENT ENGINEERING:BOB PLANT 503-644-7153 CONDUIT WP 4 OF 6 PROJECT C.O.AREA:TIGARD NUMBER:5105862 EXCH.CODE51351 ATCO ENGINEERING-JIM ZERFING 503-502-5413 51351-5105862 AWN DATE: I ENGR BOB PLANTWANINGTON 7-7-201 PHONE: 50384A-7153 FILE: $GALE:1.50 TAX DISTRICT: jDWG 13 OF 15 TWNSHP: RNIG I SEC. TGRD-HWY99 AT GAARDE/MCDONALD ST - STREET IMPROVEMENT FRONTIER CONDUIT ALL NOTES ON CONDUIT WORK PRINT 6 APPLY TO THIS WORK PRINT Lu Q PLACE SIDEWALK z ANCHOR AND DOW N PLACE DOWN GUY GUY-T LEAD o TO PGE ANCHOR EXISTING POLE EXISTING POLE U) FTR#500594 FTR#34463 PGE#C2102C2182 PGE#C2102C3579 U SW MCDONALD ST w Q � EXISTING POLE EXISTING POLE FTR#36552 C) PLACE ANCHOR AND DOWN GUY U) FRONTIER CONTACTS WP 14 OF 15 J_ftanfier, INSPECTOR:BILL LAFLUER 503-936-2035 CONDUIT WP 5 OF 6 GRD-HWY99 AT GAARDE/MCDONAL ENGINEERING: BOB PLANT 503-644-7153 51351-5105862 STREET IMPROVEMENT PRWEC7 C.O.AREA TKiARD ATCO ENGINEERING-JIM ZERFING 503-502-5413 NUMBER:5105862 EXCH.CODE:51351 DRAWN DATE: ENGR. BOB PLANT :WAHINGTON 7-7-2014 PHONE: 5034"7153 FILE' SCALE:1.5D TAX DISTRICT' DWG 14 OF 15 TWNSHP: RNO: SEC: TGRD-HWY99 AT GAARDE/MCDONALD ST - STREET IMPROVEMENT FRONTIER CONDUIT GENERAL CONTRACTOR NOTES BURIED do UNDERGROUND CABLE AND CONDUIT 1. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH THE FIELD SIDE ROAD SIDE ORDINANCES OF THE COUNTY /CITY DURING ALL PHASES OF CONSTRUCTION BEING COMPLETED ON THIS WORK ORDER. a�yy,d. 2. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING AND SAVING 24' FROM DAMAGE ALL SUBSTRUCTURES LOCATED WITHIN THE 24" 30" WORK AREAS COVERED BY THIS WORK ORDER. SHOULD DAMAGE 1� OCCUR, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL DAMAGES AND REPAIRS TO ANY SUBSTUCTURE. 46" ��BACNFILV/ cAs� 3. IF STREETS ARE TO BE SAWCUT, ALL WORK WILL COMPLY TO COUNTY/CITY Po (CLEu�p�n CAS 12 SAWCUT AND COMPACTION SPECIFICATIONS.SELECT BACKFILL MAY BE REQUIRED. 0 - ,O I // 4. ALL SUBSTRUCTERS ARE TO BE EXPOSED BY THE CONTRACTOR PRIOR TO BORING --�3' �12 12" 5. CONTRACTOR IS TO PROVIDE ALL CRUSHED ROCK, ASPHALT AND CONCRETE REQUIRED TRENCH SIDE VIEW FOR BACKFILL AND RESTORATION BY THIS WORK ORDER.THIS SHALL INCLUDE THE REMOVAL AND REPLACEMENT OF GRASS SOD AS REQUIRED. FRONTIER WILL USE CENTER 6. ALL EXCESS BACKFILL IS TO BE REMOVED FROM THE WORKSITE AND NO TRENCH Egl OF TRENCH LINE. IS TO BE LEFT OPEN OVERNIGHT. 7. ALL EXCAVATION AREAS ARE TO BE RESTORED TO ORIGINAL CONDITION OR BETTER. 8. ALL TRAFFIC CONTROL AND LANE CLOSURES ARE TO BE COORDINATED WITH THE COUNTY /CITY AGENCY. PUBLIC SAFETY SHALL BE OF THE HIGHEST PIORITY. 9. OSHA SAFETY REQUIREMENTS PERTAINING TO ALL WORK OPERATIONS. 10. ALL WORK IN THE COUNTY/CITY RIGHT—OF—WAY IS TO BE PERFORMED IN NOTE: WHERE PRACTICAL ALWAYS PUCE ACCORDANCE WITH THE CONDITIONS OF THE COUNTY/CITY PERMIT. PVC RISER ON SIDE OF POLE AWAY FROM ONCOMING�TgRAFFIC. NOTE: 24 NOTE: "RADIUS BEND$ CONSTRUCnM NOTES RESPECTIVELY. PRIOR M NSTALuna1 OF THE SON AT f ADE LEVEL,PLACE T'MNUS NOOK Ni RDTTDM OF HOLE Au suns ro eF tb cearEs ANo Sn UP r�WTTO.OF maL it Aql�FEswn aAa a mNe o�nAoaT,nRm wino urc •■R�Rll aro aAR UNEL 1 0'MIN.COVER BELOW FINISHED GRADE Onf V■ T ,� 24 /36'RADIUS WP 15 OF 15 GRD-HWY99 AT GAARDE/MCDONAL TYPICAL DETAIL OF RISER CONDUIT WP 6 OF 6 STREET IMPROVEMENT TO POLE PROJECT C.O.AREA TIGARD TYT,CAL MOI1,Rl1 51351-5105862 NUMBER:5105862 EXCH.CODE:51351 HANOHOLE ARRANOEMENT DRAWNDATE lUd : ENGR: BOB PLANT :W.4iINGTON PUCE DUCTS III CORNERS OF E 1TD'HANDNE UNLESS On1HERNSEERAlSE NOTED 7�7-N114 PHONE: 503.644-7153 FILE: SCALE;1-50 ITAXDISTRICT. DWG 15 OF 15 TWNSHP: RNG: SEC: