Loading...
Plans • .. .. .. •. . • •. •.•• • •.• • . . . .. .. . . • .DURHAM ADVANCED WASTEWATE R TREATMENT FACILITY - U - . . ... ... . P HAS E 5D2 --- � - •• •• ••• •-• • ... ... .. • • COGENERATIONANDBROWN • • • . GREASE RECEIVING FACILITIES A 2- PROJECT 6471 /..- G 6 11? I- CI Y OF T GARD CLEAN WATER SERVICES U 5 roved -� � ���� f ( ) s TIGARD OREGON Conditionally Approved ForonlythewoL� ::013d ca9yz PROJECT PERMIT NO. LOCATION See Letter to:Follow ( ::: 90% REVIEW SUBMITTAL - DRAWINGS y� °.7s' ; r�-= `'� Job Address �, orb. .o•wr--. gy, = Data' : �� ASTO•IA - / / if �a E HOOD RIVER '.' - _ •� FF _ Ill : W •am..�, t PORTLAN. v PENDLETON Raw ` ad..• TIGARD�I� THE DALLES TILLAMOOK ENTERPRISE ton. . Y w. 07.1!1 LA GRANDE - ii OFFICE COPY z . . EM MilipMill LIMII MR ..._r-* U • PRINEVILLE I -- i'� i _ ,1 a © `+� SISTER REDMOND y/ � y :END VAL rw EUGEN ;ogq ':.., a le, .0 TIGARO�_/---r I* `b BURN `% !•:_�'`IE. .., k'�• e w ��' RHAM' d, M ROSEBURG OREGON PROJECT LOCATION j 3 . r4"`°" . ,-,' o DURHAM FACILITY i\ .D•.. 1 16060 AND 16850 II ' TM� `Jean 0. N.I.C. /����'�._ SW 85TH AVE � � of • ry TIGARD,OR 97224 _ GOLD I a BEACH EDFORD �r ••• _ 4 c.I K • •TH FALLS :; ++� F -•� rmH UALATI ,• LAKEVIEW _ +, �.,.. >� I� w `�i v - °. i- 1- N O VICINITY MAP N (I) LOCATION MAP N e. al G 9 MN: BDR °Ri0 CLEAN WATER SERVICES SHEET TITLE: SHEET:)( OF:)( DWG U: PRELIMINARY C] DATE: GENERAL NOT FOR DURHAM AWWTF OTT APR2013 CONSTRUCTION ° DsN: BDR CAD FILE 001 6001 THIN BAR H IS C1eanWaber Services CH2M H I LL PHASE 5D2 001-G-001 _ TITLE,VICINITY AND PLC* XXXX g cAOFaEF: ONE INCH WHEN Q CHIC BWR 001-G-001_422389.dgn DRAWING IS O.re.mmitme.tiFClear COGENERATION AND BROWN 2 H PD:LEC SCALE AS SHOWN FULL SCALE. REVk DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hvry. Hillsboro,Oregon 97.23-9378 GREASE RECEIVING FACILITIES LOCATION MAPS s,, 6471 PNGH STAMP: LL • •• •• •• • • • • •• w • • • • • • •• •• • • • • • •• INDEX TO DRAWINGS ••• • .. • • • • • • • • • • • • • • • • • • •• SHT NO.DRAWING NO. SHEET TITLE/DESCRIPTION SHT NO.DRAWING NO SHEET TITLE!DESCRIPTION SHT NO DRAWING NO. SHEET TITLE/DESCRIPTION 001-GENERAL 008-INSTRUMENTATION AND CONTROL-CONTINUED 716-COGENERATION FACILITY-CONTINUED ���"" ** ••• • 1 001 - G - 001 TITLE.VICINITY.LOCATION MAPS 68 008 - I - 006 P&ID-ENGINE HEAT RECOVERY 122 716 - S 341..F?OUNDATICL Pr_AI�L • •• • 2 001 - G - 002 INDEX TO DRAWINGS 69 008 - I - 007 P&ID-ENGINE LUBE OIL 123 716 - 9'- 151• ROOF PRA RING PLANS • • • 3 001 - G - 003 ABBREVIATIONS-1 70 008 - I - 007A P&ID-ENGINE ROOM VENTILATION 124 716 - S�•IO1 •SECTIO?J•• •.. .••• • 4 001 - G - 004 ABBREVIATIONS-2 71 008 - I - 008 P810-FOG WASTE RECEIVING 125 716 - S - 302 SECTIONS 5 001 - G -005 OVERALL GENERAL LEGEND 72 008 - I - 009 P&ID-FOG WASTE STORAGE AND FEED 126 716 - S - 501 DETAILS 6 001 - G -010 CIVIL LEGEND 73 008 - I - 010 P&ID-DIGESTER FOG FEED 127 716 - S -R502 DETAILS 7 001 - G - 011 INSTRUMENTATION AND CONTROL LEGEND-1 74 008 - I - 011 P&ID-HOT WATER SYSTEM 128 716 - S •:it •VTAVirl • •• •• 8 001 - G - 012 INSTRUMENTATION AND CONTROL LEGEND-2 75 008 - I - 012 P&ID-HEATING LOADS DIGESTER COMPLEX 2 129 716 - S -104 DETAILS 9 001 - G - 013 ARCHITECTURAL GENERAL NOTES,SYMBOLS AND WALL TYPES 76 008 - I - 013 P&ID-HEATING LOADS FOG WASTE RECEIVING 130 716 - S 05 ETA ,• ••• •• • • 10 001 - G - 014 ARCHITECTURAL BGR LIFE SAFETY PLAN AND CODE DATA 77 008 - I - 014 P&ID-HEATING LOADS YARD,TUNNEL,SOLIDS BLDG 131 716 - M - 31 .PiAINTAPP PI•AN• • • •• 11 001 - G - 015 ARCHITECTURAL COG LIFE SAFETY PLAN AND CODE DATA 78 008 - I - 015 MD-HEATING LOADS DIGESTER COMPLEX 1 132 716 - M - 141 FLOOR PLAN 12 001 - G - 016 STRUCTURAL GENERAL NOTES-SHEET 1 OF 2 79 008 - I - 100 CONTROL SYSTEM BLOCK DIAGRAM 1 133 716 - M -301 SECTIONS 13 001 - G - 017 STRUCTURAL GENERAL NOTES-SHEET 2 OF 2 80 008 - I - 101 CONTROL SYSTEM BLOCK DIAGRAM 2 134 716 - M -302 SECTION 14 001 - G - 018 STATEMENT OF SPECIAL INSPECTIONS-SHEET 1 OF 4 81 008 - I - 501 CONTROL PANEL LAYOUT CONCEPTS 135 716 - M - 303 SECTIONS 15 001 - G - 019 STATEMENT OF SPECIAL INSPECTIONS-SHEET 2 OF 4 82 008 - I - 502 TYPICAL TERMINAL BLOCK MARKING AND PANEL POWER 136 716 - M -304 SECTIONS 16 001 - G - 020 STATEMENT OF SPECIAL INSPECTIONS-SHEET 3 OF 4 83 008 - I - 503 EXAMPLE LOCAL CONTROL STATION DETAIL 137 716 - M -502 ENLARGED PLAN AND ISOMETRIC 17 001 - G - 021 STATEMENT OF SPECIAL INSPECTIONS-SHEET4 OF 4 84 008 - I - 504 TYPICAL ANALOG PLC I!O MODULE WIRING 138 716 - H - 141 FLOOR PLAN 18 001 - G - 026 MECHANICAL LEGEND 85 008 - I - 505 TYPICAL DISCRETE PLC I/O MODULE WIRING 139 716 - H - 301 SECTIONS 19 001 - G - 027 HVAC AND PLUMBING LEGEND 86 009 - I - 600 WIRING DIAGRAM LEGEND 140 716 - H - 302 SECTION 20 001 - G - 028 HVAC SCHEDULES 87 008 - I - 601 TYPICAL WIRING-OPEN/CLOSE VALVES 141 716 - H - 601 CONTROLS 21 001 - G - 029 ELECTRICAL LEGEND-1 88 008 - I - 602 TYPICAL WIRING-GRINDER CONTROL PANELS 142 716 -EP -141 PROCESS PLAN 22 001 - G -030 ELECTRICAL LEGEND-2 89 008 - I - 701 TYPICAL WIRING-ANALOG RADAR LEVEL INSTRUMENTS 143 716 -EF -141 FACILITY PLAN 23 001 - G - 031 ELECTRICAL GROUNDING SYSTEM DIAGRAM 90 008 - I - 702 TYPICAL WIRING-ANALOG TWO-WIRE INSTRUMENTS 144 716 - E -601 CABLE BLOCK DIAGRAMS 24 001 - G - 032 DESIGN CRITERIA 91 008 - I - 703 TYPICAL WIRING-ANALOG ELECTROMAGNETIC FLOW METERS 145 716 - E - 602 CABLE BLOCK DIAGRAMS 25 001 - G - 033 PROCESS FLOW DIAGRAM 146 716 - E - 603 CABLE BLOCK DIAGRAMS 26 001 - G - 034 PIPING SCHEDULE-1 715-BROWN GREASE RECEIVING FACILITY 147 716 - E - 004 CABLE BLOCK DIAGRAMS 27 001 - G - 035 PIPING SCHEDULE-2,NOTES 148 716 - E - 620 PANELBOARD SCHEDULES 28 001 - G - 036 HOT WATER SCHEMATIC-1 92 715 - A - 141 FLOOR PLAN 29 001 - G - 037 HOT WATER SCHEMATIC-2 93 715 - A - 151 ROOF PLAN 717-GAS PURIFICATION FACILITY 30 001 - G - 038 HOT WATER SCHEMATIC-3 94 715 - A - 201 ELEVATIONS 31 001 - G - 039 HOT WATER SCHEMATIC-4 95 715 - A - 301 SECTIONS 149 717 -SM -141 PLAN 96 715 - S - 141 FOUNDATION PLAN 150 717 -SM -301 SECTION AND DETAIL 005-SITE DEVELOPMENT 97 715 - S - 151 ROOF FRAMING PLAN 151 717 - E - 141 PLANS AND DIAGRAMS 98 715 - S - 301 SECTIONS 32 005 - C - 100 OVERALL SITE PLAN 99 715 - S - 302 SECTIONS 740-DIGESTER COMPLEX 1(DC11 33 005 -CE -100 EROSION AND SEGMENT CONTROL COVER SHEET 100 715 - S - 303 SECTIONS AND DETAILS 34 005 -CE -101 EROSION AND SEGMENT CONTROL PLAN WEST 101 715 - S - 501 DETAILS 152 740 -SM -101 DEMOLITION PLANS 35 005 -CE -102 EROSION AND SEDIMENT CONTROL PLAN EAST 102 715 - M - 131 DRAINAGE PLAN 153 740 - M - 130 LOWER FLOOR PLAN AND DETAIL 36 005 -CE -501 EROSION AND SEGMENT CONTROL DETAILS 103 715 - M - 141 PLAN AND PARTIAL TOP PLAN 154 740 - M - 140 GAS EQUIPMENT ROOM PLAN AND SECTION 37 005 -a -101 LOCATION PLAN AREA 101 104 715 - M -301 SECTIONS 155 740 - E - 140 GAS EQUIPMENT ROOM PARTIAL PLAN AND SCHEDULES 38 005 -a -102 LOCATION PLAN AREA 102 105 715 - M -302 SECTIONS 39 005 -CL -103 LOCATION PLAN AREA 103 106 715 - M -303 SECTIONS 750-DIGESTER COMPLEX 2(DC2) 40 005 -CL -104 LOCATION PLAN AREA 104 107 715 - M -501 DETAILS 41 005 -CL -501 ROAD SECTIONS 108 715 - M -502 ISOMETRIC 156 750 - M - 130 LOWER FLOOR PLAN 42 005 -CG -101 GRADING PLAN AREA 101 109 715 - H - 141 FLOOR PLAN 157 750 - M - 140 GROUND FLOOR PLAN 43 005 -CG -102 GRADING PLAN AREA 102 110 715 - H - 301 SECTIONS 158 750 - M - 301 SECTIONS 44 005 -CG -103 GRADING PLAN AREA 103 111 715 - H - 601 CONTROLS 159 750 - E - 131 LOWER PROCESS PLAN AND DIAGRAMS 45 005 -CG -104 GRADING PLAN AREA 104 112 715 -EP -140 PROCESS FLOOR PLAN AND PARTIAL TOP PLAN 160 750 - E - 140 GROUND FLOOR PLAN AND CABLE BLOCK DIAGRAMS 46 005 -CG -201 ROAD PROFILES 113 715 -EF -140 FACILITY FLOOR PLAN AND PARTIAL TOP PLAN 47 005 -CG -202 ROAD PROFILES 114 715 - E - 601 CABLE BLOCK DIAGRAMS 900-ELECTRICAL • 48 005 -CG -501 GRADING DETAILS 115 715 - E -602 CABLE BLOCK DIAGRAMS 49 005 -CG -502 GRADING DETAILS 116 715 - E - 620 PANEL SCHEDULES 161 900 - E - 101 SITE PLAN AREA 101 50 005 -CY -101 YARD PIPING PLAN AREA 101 162 900 - E - 102 SITE PLAN AREA 102 ,a„ 51 005 -CY -102 YARD PIPING PLAN AREA 102 716-COGENERATION FACILITY 163 900 - E - 103 SITE PLAN AREA 103 52 005 -CY -103 YARD PIPING PLAN AREA 103 164 900 - E - 104 SITE PLAN AREA 104 — 53 005 -CY -104 YARD PIPING PLAN AREA 104 117 716 - A - 141 FI.00R PLAN 165 900 - E - 601 OVERALL ONE-LINE DIAGRAM w 54 005 -CY -201 18'DG PLAN AND PROFILE STA 0+00 TO 5+00 118 716 - A - 151 ROOF PLANS,ENLARGED PLAN AND DETAIL 166 900 - E - 602 OVERALL ONE-LINE DIAGRAM 2 55 005 -CY -202 18'DO PLAN AND PROFILE STA 5+00 TO 10+00 119 716 - A -201 ELEVATIONS 167 900 - E - 603 716MCC-1401 ONE-LINE DIAGRAM 56 005 -CY -203 18'DG PLAN AND PROFILE STA 10+00 TO 13+43 120 716 - A - 202 ELEVATIONS 168 900 - E - 604 715MCC4401 ONE-LINE DIAGRAM O 57 005 -CY -204 SDI SAN PROFILES 121 - - 301 SECTIONS _-i 716 A 169 900 - E - 605 20MCC99101 AND 20MCC99102 ONE-LINE DIAGRAM 58 005 -CY -501 YARD PIPING DETAILS 170 900 - E - 612 20MCC99101 AND 20MCC99102 ELEVATIONS 59 005 -CY -502 YARD PIPING DETAILS 171 900 - E - 620 COMMUNICATIONS NETWORK CABLE BLOCK DIAGRAMS o 60 005 -CY -503 YARD PIPING DETAILS 172 900 - E - 640 DUCTBANK SCHEDULE g 61 005 -CY -504 YARD PIPING DETAILS 173 900 - E - 650 LUMINAIRE SCHEDULE E, `" w 008-INSTRUMENTATION AND CONTROL a O 62 008 - I - 001 P&ID-DIGESTER GAS STORAGE O 63 008 - I - 002 P810-DIGESTER GAS PURIFICATION SYSTEM 1 64 008 - I - 002A P&ID-DIGESTER GAS PURIFICATION SYSTEM 2 65 008 - I - 003 P&ID-DIGESTER GAS PURIFICATION SYSTEM 3 c 66 008 - I - 004 PSID-ENGINE FUEL SYSTEM O 67 008 - I - 005 P&ID-COGEN ENGINES of m M N N Nr al 04 0 I?• [V BDR oA�. CLEAN WATER SERVICES SHEETMLE GENERAL SHEET:)( OF�XX DWGB PRELIMINARY - NOT FOR o DST+: DB DWG St. 001-G-002 THIS BAR IS DURHAM AWWTF DATE: APR 2013 CONSTRUCTION CH2MHILL PHASE 5D2 P�# XXXx 001-G-002 w Clean Water Services INDEX TO DRAWINGS 001- -0 OA: ONE INCH WHEN a CHIC JEG 001-G-002A 422389.dgn DRAWING IS Oar commitment;m clear COGENERATION AND BROWN APPD:LEC SCALE AS SHOWN FULL SCALE. LL REV. DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hwy Hillsboro.Oregon 97123-9379 GREASE RECEIVING FACILITIES Pia. 6471 ENGR STAMP: • •• •• •• • • • • •• ~ SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION • • •• •• • ABBRE;VIATION; • _ - __ ONE LINE DIAGRAMS-1 ONE LINE DIAGRAMS-2 CONTROL DIAGRAMS-2 • • ABBREVII.TION • DECCRipTION • •• A AMPERE,AUTOMATIC CIRCUIT BREAKER,THERMAL MAGNETIC TRIP SHOWN, NON DRAWOUT FUSED SWITCH,MEDIUM VOLTAGE AC ALTERNATING CURRENT I 400 ---I I---�— REMOTE DEVICE AFD • • AFF • • • • AD•USTABIlc FREQUENCY DRy/C• n ABOHE FWISIEO FLOCP • AS 2-F- CIRCUIT BREAKER.STATIC TRIP UNIT,SENSOR AMP MEDIUM VOLTAGE CABLE STRESS CONE TYPE OO..�� O TIME DELAY RELAY CONTACT,NORMALLY OPEN, AFG • • •• • P11O`•E FINISIIEDFRADG • AF °f TRIP AND FRAME RATINGS SHOWN,3 POLE,UNO TERMINATION,OPEN TERMINATOR OR ELBOW CLOSES WHEN ENERGIZED AND TIMED OUT ATS • • • • Fl1TdMATII TRANSFER■SWITCH • • • • • • • • • • • n TIME DELAY RELAY CONTACT,NORMALLY CLOSED, BFG • BELOW FINISHED GRADE • CIRCUIT BREAKER,MAGNETIC TRIP ONLY,TRIP TERMINAL BLOCK LUG OPENS WHEN ENERGIZED AND TIMED OUT BKR BREAKER 100/M RATING SHOWN,3 POLE,UNO BSC BARE STRANDED COPPER O TIME DELAY RELAY CONTACT,CLOSES WHEN ENERGIZED, T FUSED SWITCH,SWITCH AND FUSE CURRENT RATING OPENS WHEN DE-ENERGIZED AND TIMED OUT C ••• • • •L* D T• N=ALL=OR�Cb�DUCTOR,CLOSE DELTA CONNECTION ���LLL 3I llL��� �jJ 225 INDICATED,3 POLE,UNO CAP. • •CAPAC�Ofi TIME DELAY RELAY CONTACT,OPENS WHEN 1� fj� • • • SWITCH,CURRENT RATING INDICATED,3 POLE,UNO Y, WYE GROUNDED CONNECTION,SOLID GROUND ENERGIZED,CLOSES WHEN DE-ENERGIZED AND CB • •CLWR A Q • • I 100 TIMED OUT CLE • •CLIgRfi�1T LSMITjNC USA • CPT • • • WNTROL gDWCR TjRAIISjORMER —� FUSE,CURRENT RATING AND QUANTITY INDICATED ,.,'1�1 D MOTOR SPACE HEATER CR CONTROL RELAY 60 (3) 800/1200:5 . BUSHING CURRENT TRANSFORMER,MULTI-RATIO v U Ll' CT CURRENT TRANSFORMER,CABLE TRAY AND QUANTITY INDICATED 1 (3) O TERMINAL BLOCK,REMOTE DC DIRECT CURRENT I --I I--.xN— MAGNETIC STARTER WITH OVERLOAD, DWG DRAWING NEMA SIZE INDICATED,FVNR UNO CONTROL DIAGRAMS-1 E EMPTY --- - 0 TERMINAL BLOCK,INTERNAL EX,EXST EXISTING D-- PUSH-BUTTON SWITCH,MOMENTARY CONTACT, AFD ELECTRONIC STARTER/SPEED CONTROL F,FU FUSE NORMALLY OPEN RVSS=REDUCED VOLTAGE SOFT STARTER ,�y� Ij I] FUSE,RATING INDICATED FRED FREQUENCY I AFD=AC ADJUSTABLE FREQUENCY DRIVE PUSH-BUTTON SWITCH,MOMENTARY CONTACT, DC=DC ADJUSTABLE SPEED DRIVE NORMALLY CLOSED CPT I G GROUND 1�.�-� GFCI GROUND FAULT CIRCUIT INTERRUPTER OFF SELECTOR SWITCH-MAINTAINED CONTACT-CHART GND GROUND I LAND REMOTE IDENTIFIES OPERATION WHEN NEEDED FOR CLARITY: 120 TRANSFORMER,CONTROL POWER • CABLE OR BUS CONNECTION POINT XOO HH HANDHOLE HOA HAND-OFF-AUTO POSITION GROUND SYSTEM PLAN HP HORSEPOWER CKT HAND OFF REMOTE X-CLOSED CONTACT HS HAND SWI I CH K I KEY INTERLOCK OOX 1 X 0 0 O-OPEN CONTACT HZ HERTZ —.0--0_ 2 0 0 X ® GROUND ROD • SURGE ARRESTER(GAP TYPE) IC INTERRUPTING CAPACITY ® GROUND ROD IN TEST WELL 0 -67----0— TOGGLE SWITCH,ON-OFF TYPE J,JB JUNCTION BOX MOTOR,SQUIRREL CAGE INDUCTION- tORSEPOWER INDICATED O ——G —— GROUNDING CONDUCTOR.SIZE AS INDICATED KA KILOAMPERES KV KILOVOLT SELECTOR SWITCH,ON-OFF TYPE KVA KILOVOLT AMPERES VS p, GROUND ROD TO CABLE KVAR KILOVOLT AMPERES-REACTIVE • 0 ANALOG METER WITH SWITCH-SCALE RANGE SHOWN —(GT KW KILOWATTS 0-600V V=VOLTAGE KW=KILOWATTS _0 0— MUSHROOM HEAD SWITCH -- FLEXIBLE GROUND STRAP LP LIGHTING(INSTRUMENTATION)PANELBOARD A=AMPERAGE KVAR=KILOVARS CABLE TO TOP OF GROUND ROD M MAGNETIC CONTACTOR COIL, PF=POWER FACTOR MOTOR,MANUAL A INDICATING LIGHT,PUSH-TO-TEST,LED TYPE, GR DP61 LETTER INDICATES COLOR MCC MOTOR CONTROL CENTER A-AMBER G-GREEN S-STROBE PIGTAIL FOR CONNECTION TO EQUIPMENT MH MANHOLE,METAL HALIDE,MOUNTING HEIGHT .... DIGITAL POWER METER MULTIFUNCTION B-BLUE R-RED CABINET OR FRAME MIN MINIMUM ( ) MSC MANUFACTURER SUPPLIED CABLE C-CLEAR W-WHITE G EQUIPMENT GROUND BUS 1 GROUND NC NORMALLY CLOSED _ N EQUIPMENT NEUTRAL BUS NIC NOT IN CONTRACT ETM I ELAPSED TIME METER N.O. NORMALLY OPEN I 5 KVA I NTS NOT TO SCALE ,L,480-120/240V 1 PH TRANSFORMER,SIZE,VOLTAGE RATINGS, OM MOTOR STARTER CONTACTOR COIL OL OVERLOAD RELAY ryr'■ AND PHASE INDICATED J PULL BOX CRX CONTROL RELAY,X INDICATES NUMERICAL ORDER PP POWER PANELBOARD PB IN CIRCUIT _ SHIELDED ISOLATION TRANSFORMER D RGS RIGID GALVANIZED STEEL CONDUIT X TIME DELAY RELAY,X INDICATES NUMERICAL ORDER a 480-120V IN CIRCUIT SPD SURGE PROTECTIVE DEVICE POTENTIAL TRANSFORMER,VOLTAGE RATING SS START/STOP 2 (3) AND QUANTITY INDICATED .__I CONTACT-NORMALLY OPEN SSMS SOFT-START MOTOR STARTER SST STAINLESS STEEL(TYPE 316) Lii SV SOLENOID VALVE 100:5 CURRENT TRANSFORMER,RATIO(100:5)AND -It CONTACT-NORMALLY CLOSED SWGR SWITCHGEAR ~ (3) QUANTITY INDICATED(3) TC TRAY CABLE 0 TYP TYPICAL J a ® CONNECTION POINT TO EQUIPMENT SPECIFIED IN OTHER UON UNLESS OTHERWISE NOTED DIVISIONS.RACEWAY,CONDUCTOR AND CONNECTION IN THIS DIVISION V VOLTAGE,VOLTS VFD VARIABLE FREQUENCY DRIVE g W WATTS N WP WEATHERPROOF i Q XFMR TRANSFORMER 0 O D. NOTES: 1. THESE ARE STANDARD LEGEND SHEETS.SOME SYMBOLS AND ABBREVIATIONS a, 1. APPEAR ON THE LEGEND AND NOT ON THE DRAWINGS. v 2. FOR ADDITIONAL ABBREVIATIONS OF OTHER DIVISIONS(HVAC,MECHANICAL,AND N STRUCTURAL/ARCHITECTURAL)SEE OTHER LEGENDS. N of SHEET: oF. Dwca PRELIMINARY c? DAN, JO DA,E: CLEAN WATER SERVICES GENERAL XX - NOT FOR aw■o DURHAM AWWTF PL°T APR CONSTRUCTION Lii CHZMHILL PHASE 5D2 ELECTRICAL 001-G-029 DsN: RSH owc r 001-G-029 THIS BAR IS �1 C CAD FILER ONE INCH WHEN ' 'eanWat�L Services z "K: JKL 001-G-029_422389.dgn DRAWING IS Oar commitment iscies( COGENERATION AND BROWN LEGEND- 1 PLC XxxX J APPD:LEC SCALE AS SHOWN FULL SCALE. REVM DATE B APVR DESCRIPTION 2550 SWHalsboroHwy. I ,n.,T-,,Or'q 971:3 q.179 GREASE RECEIVING FACILITIES PR r 6491 EN64STF".,P: LL I • •• •• •• • • • • • • • • • • • • • • • • • • SYMBOL DESCRIPTION SYMBOL DESCRIPTION CIRCUIT AND RACEWAY •• •• • • • • • N• • • •• • • • POWER SYSTEM PLAN-1 POWER SYSTEM PLAN-2 GENERAL CIRCUIT CONDUCTOR AO CtADUITDENYIISICATIOIII• •• xx CONNECTION POINT TO EQUIPMENT SPECIFIED. ® iQc CONVENIENCE RECEPTACLE-DUPLEX UNLESS NOTED RACEWAY,CONDUCTOR,TERMINATION AND CONNECTION 2 OTHERWISE MCC-A IN THIS DIVISION. WP-WEATHERPROOF C-CLOCK HANGER POWER CIRCUIT CALLOUTS ••- ••• COA1A11U4/IIC0•NS CIRaIT CALtOUTS or A MAJOR IDENTIFYING SYMBOL COMPONENT OR DEVICE-NAME TL-GFCI-GROUND FAULT CIRCUIT INTERRUPTER RESISTANT [P1] I12"FLEX,2#12,#1261 [P231 [7'C,3#8,2#14,1#10G]: I�1]• :1"C,l CATS] •• OR IDENTIFYING SYMBOL AS SHOWN. SUBSCRIPT NUMBER AT RECEPTACLE INDICATES CIRCUIT [P2] [3/4"C,2#12,1#12G] [P241 [1"C,3#8,3#14,1#10Gr•• • [C2] • 0[1 114'C,2-CAT 615 • • IIIIIIIIII■X PANELBOARD-SURFACE MOUNTED 20® RECEPTACLE,SPECIAL PURPOSE-NEMA CONFIGURATION [P3] [3/4"C,3#12,1#12G] [P25] [?C,3#8,4#14,1#100] • •[E3] • [1 1/��3-CATB?• • LPXXA AND AMPERAGE INDICATED [P4] [314"C,4#12,1#12G] [P261 (VC,3#8,5#14,1#10G] EMPTY CONDUIT f 1T PANELBOARD LETTER OR NUMBER [P5] [314"C,5#12,1#126] [P27] [1"C,2#6,1#106] H 4PORTDATA/VOIPOUTLET [P6] (3l4"C,6#12,1#126] 1P281 [1"C,3#6,1#106] ••• •[1•`E=1] • �' W PIVI.:t�tING] FACILITY NUMBER • 5� • • [� • LP-LOW VOLTAGE PANEL [P7] (3/4•C,6#12,2#12G1 [P28A] [1'C,3#6,1#8G1 • [•E-2]• [Ir'C,SJITIO PILL STRING] DP-DISTRIBUTION PANEL IQ TELEPHONE OUTLET [P81 [314"C,8#12,1#1201 [P291 [1"C,3#6,2#14,1#100] : 4E-3]:•: [;'r/teC,4ITFjP4L O RING] - PANELBOARD-FLUSH MOUNTED [P9] [3/4"C,3#12,2#14,1#12G] [P301 (1"C,3#6,3#14,1#100] • •ISE14] • [f 1/211C,WITI1PI.L STRING] Li I TERMINAL JUNCTION BOX LIGHTING SYSTEM PLAN [P10] [314"C,3#12,3#14,1#12G] [P311 [1"C,3#6,4#14,1#10G] [CE-5] [2"C,WITH PULL STRING] [P11] [314"C,3#12,4#14,1#12G] [P32] [1"C,3#6,5#14,1#10G] [CE-6] (3"C,WITH PULL STRING] 0 MOTOR,SQUIRREL CAGE INDUCTION 0 or Q LUMINAIRE,SEE SCHEDULE [P12] [3/4"C,3#12,5#14,1#126] [P33] [1'C,3#4,1#8G] [CE-7] 14•C,WITH PULL STRING] ]P131 [3/4"C,3#12,6#14,1#126] ]P341 [1 1/4'C,3tf4,3#14,1#8G] [CE-8] (5"C,WITH PULL STRING] [P141 [3/4"C,3#12,7#14,1#12G] [P35] [1 1/4"C,3#4,5#14,1#8G) --LPXXA HOME RUN-DESTINATION SHOWN II LUMINAIRE,SEE SCHEDULE l [P151 [3/4•C,2#10,1#106] [P361 [1 1/4"C,3#3,1#8G] POWER CABLE CIRCUIT CALLOUTS [P161 [3/4"C,3#10,1#10G] [P371 [1 1/4"C,3#3,3#14,1#8G] or� EXPOSED CONDUIT AND CONDUCTORS' ROD LUMINAIRE WITH INTERNAL BATTERY BACKUP, [1.16A1 [3/4"C,4#10,1#lOG] [P38] [1 1/4"C,3#2,1#6G] [PC1] [314"C,1(3C#12,1#12G)TYPE 2] SEE SCHEDULE [P17] [3/4"C,#10,2#14,1#10G] [P39] [1 1/4'C,3#1,1#6G] [PC2] [3/4"C,1(3C#10,1#12G)TYPE 2] NOTE: UNMARKED CONDUIT RUNS CONSIST OF TWO NO.12,ONE NO.12 GROUND `r1=1 or 0-C) LUMINAIRE AND POLE,SEE SCHEDULE [P18) [3/4"C,3#10,3#14,1#106] [P39A] [1 1/2"C,4#1,1#6G] [PC3] [t"C,1(3C#8,1#106)TYPE2] ALL CONDUCTORS IN 3/4" CONDUIT. RUNS MARKED WITH CROSSHATCHES INDICATE [P19] [3/4•C,3#10,4#14,1#10G] [P401 [1 1/2"C,3#1,3#14,1#6G] [PC4] [1 1/4"C,2(3C#12,1#12G)TYPE 2] NUMBER OF NO.12 CONDUCTORS. CROSSHATCH WITH SUBSCRIPT"G"INDICATES [P20] [314"C,3#10,5#14,1#106] [P411 [1 1/2"C,3#2J0,1#6G] [PCE1 [1 1/2"C,2(3C#10,1#126)TYPE 2] GREEN GROUND WIRE. or WALL MOUNTED LUMINAIRE,SEE SCHEDULE [P211 [1"C,2#8,1#10G] [P421 [2•C,3#3/0,1#4G] [PC1A] [3/4"C,1(2C#12,1#12G)TYPE 2] 17T7 CROSSHATCHES WITH BAR INDICATE NO.10 CONDUCTOR. O-r FLOOD LIGHTS-AIM IN THE DIRECTION SHOWN [P221 [1"C,3#8,1#10G] [P431 [2"C,3#4/0,1#4G1 [PC2A] 13/4"C,1(2C#10,1#12G)TYPE 2] SIZE CONDUIT ACCORDING TO SPECIFICATIONS AND APPLICABLE CODE. STANDBY LIGHTING UNIT,SURFACE MOUNTED, ANALOG CIRCUIT CALLOUTS CONTROL CIRCUIT CALLOUTS CONDUIT AND CONDUCTOR CALLOUT,SEE LEGEND. G II I> SEE SCHEDULE CONTROL CABLE CIRCUIT CALLOUTS [Al] [3/4"C,1 TYPE 3] [Cl] [314"C,MSC] [Al] XX® XI or ET LIGHTS-FILLED SECTION INDICATES LIGHTED FACE, [A2] [1"C,2 TYPE 3] [C2] [3/4•C,2#14,1#14G] [CC31 [3/4"C,1-3C TYPE 1] 7 CONDUIT DOWN ARROW INDICATES EGRESS DIRECTIONAL INDICATORS, [CC4] [3/4"C,1-4C TYPE 1] [A3] [1'C,3 TYPE 3] [C3] [3l4"C,3#14,1#146] XX=FIXTURE NUMBER,SEE SCHEDULE [A4] (1•C,4 TYPE 3] [C4] [3/4•C,4#14,1#146] [CCS] [3!4"C,1-SC TYPE 1] 0 CONDUIT UP Sa or ® SMALL LETTER SUBSCRIPT AT SWITCH AND LUMINAIRE [A55] [1 1/4"C,5 TYPE 31 [C5] (3/4•C,5#14,1#14G] [CC6] [3/4'C,1-6C TYPE 1] 2a INDICATES SWITCHING. SUBSCRIPT NUMBER [CC71 [3/4"C,1-7C TYPE 1] AT LUMINAIRE INDICATES CIRCUIT [A6] [1 1/4"C,6 TYPE 3] [C6] [3/4•C,6#14,1#146] J CONDUIT,STUBBED AND CAPPED $ [CCS] [1"C,1-8C TYPE 1] WALL SWITCH: [A7] [1 1/2"C,7 TYPE 3] [C7] [3/4"C,7#14,1#14G] 2- DOUBLE POLE [A8] [1 l/2'C,8 TYPE 3] [C8] [3/4'C,8#14,1#146] [CC9] [1"C,1-9C TYPE 1] CONDUIT TERMINATION AT CABLE TRAY 3- THREE WAY P- PILOT LIGHT [A8] [1 1/2"C,9 TYPE 3] [CC10] [1"C,1-1OC TYPE 1] K- KEY OPERATED [C9] [3/4'C,9#14,1#146] [CC11] [1"C,1-11C TYPE 1] 4- FOUR WAY D- DIMMER (A10] [2"C,10 TYPE 3] [C10] [3/4"C,10#14,1#146] EX EXISTING CONDUIT/DUCT BANK WP-WEATHERPROOF CRE-CORROSION RESISTANT [A11] [2"C,11 TYPE 3] [CC72] [1"C,1-12C TYPE I] EX- EXPLOSIONPROOF [C11] [3/4"C,11#14,1#146] - L- MOMENTARY 3-WAY [CC13] [1 1/4"C,1-13C TYPE 1] MS- MANUAL STARTER WITH OVERLOADS [A13] [2"C,13 TYPE 3] [C13] (3/4"C,13#14,1#146][A121 [2"C,12 TYPE 3] [C12] [3/4"C,12#14,1#14G] M- MOTOR RATED --CE--- CONCRETE ENCASED CONDUIT T- TIMER, [CCI9] [1 1/2'C,1-19C TYPE 1] SEE SPECIFICATIONS [A141 [2"C,14 TYPE 3] [C14J [314"C,14#14,1#14G] [CC23] [1 112•C,1-23C TYPE 1] ---DB--- DIRECT BURIED CONDUIT O [A151 [3/4"C.1 TYPE 4] [CC25] [1 1/2"C,1-25C TYPE 1] PC PHOTOCELL [C15] [314"C,15#14,1#146] [A16] (314"C,2 TYPE 4] [C16] [314'C,16#14,1#146] [CC41] [2"C,1 41C TYPE 1] I ISM* CONCRETE ENCASED DUCTBANK [All] [t'C,3 TYPE 4] MI LIGHTING CONTACTOR [A78] [1 1/4"C,4 TYPE 4] [Cu ]7 [C18] [314'C,17#14,1#146] [3/4"C,18#14,1#146] [A19] [11/4"C,5 TYPE 4] [C19] [3/4"C,19#14,1#14G] O TRANSFORMER EMERGENCY HORN(HAZARDOUS GAS) [AM] [t 1/4"C,8 TYPE 4] [C20] [1"C,20#14,1#14G] GENERAL CONTROL OR WIRING DEVICE. [A21] [1 112"C,7 TYPE 4] [621] [1•C,21#14,1#14G] 0 or® LETTER SYMBOLS OR ABBREVIATIONS A22J [ [1 1/2"C,8 TYPE 4] (C221 [1"C,22#14,1#146] INDICATE TYPE OF DEVICE [A231 [2'C,9 TYPE 4] [C23] [1•C,23#14,1#14G] w CONTROL STATION,SEE CONTROL DIAGRAMS [A241 [3/4"C,1 pr.TYPE 5] ]C241 [t'C,24#14,1#14GJ . [A251 [1•C,2-4 pr.TYPE 5] C) [C25] [1'C,25#14,1#146] FOR CONTROL DEVICE(S)REQUIRED. NONFUSED DISCONNECT SWITCH,CURRENT RATING - 30 D INDICATED,3 POLE UON. FOR 120V APPLICATIONS, di PROVIDE 1 POLE,20 AMP RATING NOTES: 1. FOR CABLE TYPES,SEE SPECIFICATIONS. O 60/40 D FUSED DISCONNECT SWITCH,CURRENT RATING INDICATED 2. WHERE CIRCUITS ARE UNDERGROUND,DIRECT BURIED OR CONCRETE ii (60/40,60=SWITCH RATING/40=FUSE RATING) ENCASED,MINIMUM CONDUIT SIZE SHALL BE 1". 3 POLE h 2 Eli COMBINATION CIRCUIT BREAKER AND S MAGNETIC STARTER,NEMA SIZE INDICATED ° m AMBIENT SENSING THERMOSTAT FOR HEAT TRACE cv id CONTROL a 0 o H HEAT TRACE CONNECTION -o m co M cm 1v M SNEETTi E: OF: DWG*. PRELIMINARY 9 DRN, JG TTGE, CLEAN WATER SERVICES GENERAL XX NOT FOR ° DM RSH Dwcrt 001-G-030 DURHAM AWWTF ELECTRICAL RD' APR 2013 CONSTRUCTION di THIS BAR IS C1eanW�cr Services CH2M H I LL PHASE 5D2 °"� 001-G-030 zCHIC JKL C.AOFILErt ONE INCH WHEN P�crt XXXX 001 G030_422389.dgn DRAWING IS Oar ceevtm••tisdar COGENERATION AND BROWN LEGEND LEC SCALE AS SHOWN FULL SCALE. REV0 DATE BY A DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES rt 6471 ENGR STAMP: LL I • •• •• •• • • • • • I • • • • • • •S •• • • • •• • NEUTRAL ••• • • •• • • • GROUNDING r TYPICAL • • • • • • • • • RESISTOR — U�GENERATOR • • • • • • • • 0KEYED NOTES GENERAL NOTES . PROVIDE GROUND CONNECTION VIA GROUND BUS BAR IN BUS • • 1. TS DIAL AA1 IS GEN C n Y NOT SHOW ALL HE REQUIRED CONNECTIONS OR DUCT • • • • lIRj•SIj1=§.•FOR AL IONAL 1N ORMATION,SEE PLAN SHEETS. E :-i--j------F:_ ---i---\_GENERATOR 2. INSTALL GROUNDING ELECTRODE CONDUCTOR,SIZED BASED ON NEC TABLE • • •• • • • • • • • EQUIPMENT • • • • 2. CONDUCTOR SIZES SHOWN ARE MINIMUM AND MAY BE LARGER THAN THE MINIMUM SIZES • 250.68 • USING HE SERVICE PHASE CONDUCTOR SIZE.BUT NOT SMALLER THAN 4• • • • REDO/IRMO BY NEC. • • • GROUND AWG. • • • ••• ••• • 3. INSTALL GROUNDING CONNECTIONS TO BUILDING STRUCTURE AND WATER PIPES AT Oa PAD-MOUNTED 3. INSTALL EQUIPMENT GROUNDING CONDUCTOR SIZED BASED ON NEC TABLE LOCATIONS THAT ARE VISIBLE AND ACCESSIBLE FOR INSPECTION,MAINTENANCE,AND I\ 250.122 USING HE FEEDER OVERCURRENT DEVICE SIZE. TESTING. .l: j. J. TRANSFORMER I WYE(PRIMARY)-DELTA(SECONDARY) 4. BOND TO GAS PIPE ON THE BUILDING SIDE OF THE GAS METER. • (((�yyy�yy/��� CONNECTION •• •• 4.•NALCO I TE OAT GROUNDING BUSHING ON EACH METALLIC SERVICE METAL WATER PIPE WITHIN I ' I 5. INSTALL GROUNDING ELECTRODE CONDUCTOR THAT IS SIZED BASED ON NEC • • •E NEC4�C Dl T. O TOE SERVICE BUS USING CONDUCTOR SIZE. THAT IS SIZED BASED •1 TABLE 250.68 USING HE SEPARATELY DERIVED SYSTEM PHASE CONDUCTOR 0•NF�J,�BL�2j:66•SI• HE SERVICE PHASE CONDUCTOR SIZE. 5 FT OF ENTRANCE — — J SIZE. • •••5. MDUI O BOND OTGR UND BUS GROUNDING USI BUSHING ON H EACH METALLIC FEN NR /II— 6. INSTALL A CONCRETE-ENCASED MAIN GROUNDING ELECTRODE IN THE BUILDING CONDUIT.BLE 250.122 BOND IN TO GROUND B ES USING CONDUCTOR THAT IS SIZED SIZE OR E NEC FOUNDATION AROUND THE ENTIRE PERIMETER OF THE BUILDING.LOCATE TABLE ATELY2 U RNG THE FEEDER CIRCUIT ENT OVERCURRENT EICSIZE. DEVICE SIZE OR HE SEPARATELY DERIVED SYSTEM OVERCURRENT DEVICE SIZE. ELECTRODE IN THE BOTTOM ONE-THIRD OF THE FOUNDATION WITH AT LEAST 3 GAS PIPE AND OTHER INCHES OF CONCRETE COVER. ir- 7. NOT USED 6. BOND HOT AND COLD WATER PIPING SYSTEMS. METAL PIPING SYSTEMS IN AND ON THE STRUCTURE 0 0 8 8. INSTALL A"MAIN GROUND ELECTRODE GROUND BAR"FOR SINGLE POINT i:)_11 GROUNDING.LOCATE AT AN ACCESSIBLE AND VISIBLE POINT NEAR THE SRVICE O ENTRANCE EQUIPMENT. MAKE CONNECTIONS TO THE GROUND BAR USING ® TWO-HOLE COMPRESSION SPADE LUGS THAT MEET IEEE 837 REQUIREMENTS. LABEL EACH CONNECTION TO THE GROUND BAR 18 '-- — 1 480Y/277 VOLT 9. NOT USED • . SERVICE ENTRANCE ° •4 I EQUIPMENT 10. NOT USED -III—III—I I—I 11—I 11- MAIN GROUNDING I I GROUND I I 11. NOT USED f ELECTRODE L N I I—I U II II=I I • GROUND BAR III—I I—I I I—III— 12. NOT USED '=III—III—III—I I _ I • • ♦ • ♦ • ♦ L 7 — _ J 13. NOT USED '1E-1 1 ....111=111E 0 < _ 0 14. INSTALL GROUNDED(NEUTRAL)CONDUCTOR THAT IS NOT LESS THAN THE PHASE CONDUCTOR AMPACITY. • 4 • J 0 15. INSTALL BONDING CONDUCTOR THAT IS SIZED BASED ON NEC TABLE 250.66 ° O USING THE SERVICE OR SEPARATELY-DERIVED SYSTEM PHASE CONDUCTOR SIZE. • 16. INSTALL IRREVERSIBLE COMPRESSION CONNECTOR WITH TAMPER-PROOF n — — — HARDWARE OR INSTALL EXOTHERMIC WELD. • _ . — 480Y/277 VOLT POWER PANELBOARD 17. NOT USED. 0 GROUND I I 18. INSTALL BONDING DUMBER THAT IS SIZED BASED ON NEC TABLE 250.68 USING THE LARGEST SERVICE OR SEPARATELY DERIVED SYSTEM PHASE CONDUCTOR. L — — J 0 15 TRANSFORMER FOR k....w1/4) SEPARATELY DERIVED I SYSTEM I I GROUND I I WYE CONNECT ON) 7 a m r ill 2 F ~O ® 14 a. - -,- - - —I 208Y/120 VOLT POWER PANELBOARD ry I WITH FIRST OVERCURRENT I GROUND NEUTRAL SEPARATELY I DIVED SYSTEM 0 W L J 0 9 0 c„---46 J J a c ce GROUNDING SYSTEM DIAGRAM !n N NTS cm a DUN: JNH °ftG CLEAN WATER SERVICES SHEET RLE. GENERAL SHEET: OF:) DWG": PRELIMINARY NI■ NOT FOR owG y� Y DURHAM AWWTF ELECTRICAL op°E: APR 2013 CONSTRUCTION id DUN: RSH GwG� 001 G-031 THIS BAR WHEN Clea„W Services C■ ■2MH ILL PHASE 5D2 P Ga , ,� 001-G-031 3 CHK: JKL 001-.E ONE INCH WHEN GROUNDING SYSTEM DIAGRAM 001-G-031_422389.dgn DRAWING IS Oat commitment lsole/r COGENERATION AND BROWN FULL SCALE. 6471 ENGR STAMP: RPM LEC SCALE: AS SHOWN aEVN DATE . BY APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES I I • • •• •• •• • • • • •• - - - I ■ • :•" ••" : : : : • • •5• •• • • • • • • • • •• •• • • • • • • •• • •• •• • •• •• • • • • • • • • )11 •• • 0 I • •S •!.IT646!' • • • • UT6401 • • • • •�•(j�\• •• • • •/ ••• ••• • IIIIIIIIH j 1=I) • •' • • • • • • • • •' • 1 =I' •_, �SMxsao2• ••• •• • • 715MX6401 Ir• I_ �: . T I - ®IIII I-�_- =��M i 9..!...-L.-_-__A I I _ �� ( r I�, �i 'pis -_ 1.� Q ,I : 1j ;; 1 8 _ o' -] • i i• ( ) III' (1 ACK VERTICALLY) liiI. : �� 715P6602-LCS 111 I DMIX8402-CS Ligi -11...111•111 414,_ _-t:1 — t. - (e III 114) hurl III • 'T ._ I _ PARTIAL TOP PLAN Z 1/4"=1•-0" (3 In I I 1► / 2111 Ruil R t t: , 5 imilLemir lin NOTE■ Fi.; _pill--1 QP1 �!•7- 1v t_ l�a -UL' GROUND BUS I( j p _q� 1 _ Ea 2Z • fH L BAR MD ( G- 116 yr;,;,tp . PSH6404 �a 14"y ,., (N p. $ 715XFMR4401 MI I �T" lil I --- •mom ' f ' r�6 r a, li - 715LCP6001 N6 BSC--- ' .©r'.1 to - ��' as"` i 41,' n-.�!7 1i. ‘,..i.,. ._,.... 715NIP4401 715/./.4402 r- ���_� I1 II ��� r�— '. 7S II/ r•, ._ 715/./.4401 NOTES I AtT4101 ,`(C��•��'I;Y,����/ _ �i TsHSa04 CI H640$ - •� ----a SV6404 SV8402 001 715AT54401 plTSao3 (iI` ; =_= 71sPSaoa ■715/.8902 `i�) - ---- `' NOTES: FCV6602 , :t... ., ss oa 1 31. SH8401 T 1. 30 PROVIDE CONCRETE ENCASED MAIN GROUNDING ELECTRODE,#4AWG,BSC, P I FIT6401 FEET LONG 1 �rS` O_7RPI W4 '?k ■'•--1 l•1' FCV8807 r _` 2. 1 y4 4 p - - = V 0 Sir ]]76801 , DISCONNECT SWITCHES MAY NOT BE SHOWN IN PLAN VIEW,BUT SHALL BE _ --f NOTE 4+�I' !' ' _ l;,'l' � •i I E.p . 'I,- ,' j +Iii7.•E'I -' 715P6603 �,, 7` ` I, PROVIDED AS INDICATED ON CABLE BLOCK DIAGRAMS AND ONE-LINE DIAGRAMS. i ` - '�,�II -^ )1 - )1 M' rf I I `I 3. APPROXIMATELOCATIONOD DEVICESANDEQUIPMENT SHOWN.FOR EXACT NI�(4p I .-.- --- .•-� _ _ -. .I, 8401 i�� 715LCP6401 I LOCATION OF DEVICES AND EQUIPMENT,SEE MECHANICAL DRAWINGS. FE 1 L I ,,g,,--t. e.,._p r4 _ J/ 715GDR640 '1�P�I . G-- 4. CONNECT TO CONCRETE ENCASED GROUNDING ELECTRODE(LIFER GROUND). 715P6604 j 715-p..0.-- 151.640 �I I II 715/.6401 ,!I I ..... . #410 BSC -- �'�• 1„ ji ��� --•',c tl, \1 715MCC4401 5. COORDINATE WALL ANCHORING WITH STRUCTURAL AS WALLS ARE ONLY 7151.6604-LCS ;I: 3 ('=- sears: 5r_= ` Ir ®1 AND WALL GROUTED. UTILIZE CHANNEL STRUT SUPPORTS BETWEEN EQUIPMENT 111 11I©� _ - II . a ....,., 'r_;=!1 ■ m _ •—N a1'�II��1 `I NOTE 1 ® m nt _-1,®9 _ 7151.6603-LCS �il di II I 11111161111111 L. Ili 1 mii,,, F IIIIIIIIIIOII lllBtllli[IIII F 0 `, ,l i i 11111l.11 f /— _ 1 i YLr001 Oa •I ,••.� '. /`YA , 715VCP6401 7i 5VCP6402 8607 715P6401-LOS - 715HWS69 01 ry 717516403-CS nnl' s ® I_ r o G ; a d _p_ N 4k_nom la I- y_/ 715VCP6403 v� J O EL o, oi PLAN Oz al PRELIMINARY W DRN: JNH D T CLEAN WATER SERVICES SHEET TITLE. SIEEPxx OF:� DWG I. v, DATE: BROWN GREASE RECEIVING FACILITY NOT FOR GSM RSH owcr. 71SEP-140 DURHAM AWWTF pA°E APR 2013 CONSTRUCTION CH2MHILL ELECTRICAL THIS aeazld�Ci SeiViC� PHASE 5D2 PROCESS FLOOR PLAN PIG ft XXXX 715-EP-140 W 715-E x ONE INCH WHEN z CAD• cHK JKL 715-EP-140_422389.dgn DRAWING IS Oar commitme•tisdeer COGENERATION AND BROWN Ill AM:LLC scALe AS SHOWN FULL SCALE. REV. DATE BY APVR DESCRIPTION 25505WHi11sboro Hwy. Hillsboro,Oregon 87123-9379 GREASE RECEIVING FACILITIES AND PARTIAL TOP PLAN P'A'S 6471 ENCRSTAMP. I • •• •• •• • • • • •• • • _ • • � • - •-• •• • • • • • • •• ... • .• ..• • • • •• • • • • • • • • • •• • • • • • •• I . • ••• • •• . • • • • • • •N A 3 • • • a. • • _. • • .-Q ...__ --s •.__. • r a•s - 1 1 1 1 11 II II 11 -'i I I I I I I i i 11 II 0 1 _ 1_L_I_I__1_I__1J_.JJ____4 ••• ••• • j"• •. r r-I-I-_,-I-_,-r-1-I—- —R • • • •, • • • • • '• _ ------_----- = II II 1 1 II It i • • • / • • • • • • 0 3.13'5.-_,r_. I I I I I I 1 I II 1 __ __� • • • . ••• •• • • 715SF8001 ' II - II II I I II 11 1 .� •.•� •• • • (�i • �.• L - ) I 1 I I ,. - -' on �� I I 1 1 11 1 1 I I 1 . 1 I ., c ! r-', III 1 Al Al •....6 . li_.., R n(23) 11 I II �R I r ■ A ° ■ --- 11 1 I(s) I I I II/ q _ �� I F.__ ' , r y II r 1I__-.._..__ — 1■t r- - _ -- --J —I--Y * I I 11 y p N (��: I ii, Al I—Z J I � NOT a • ( S € y •L.J --- 1 J I r�� (23) 715AHU8001 (23) • I 715UH8001 — 715MAU8001 1 1 i 1 1 3. __ 715SF8001 , — _ n -� I 0 1 r „SLP4�,--I PARTIAL TOP PLAN Z 11 a ru ' I I ' I I 111; I u �F (1) ■� III 1 715SF8001-LCP/ �I� 1;1 i NOTE 10 N II II I I I I W��?!g4ll(101- . -- L.1.Rr `•'-lIf;. fir'.1 _ �I� (5.`I Al� //Al 1 _-....- - _ art ►rqa- f _ �� B+ / 0 �L� _ - I H 1 I I 1 _-...._--_ -.® 1 H ..-1 (21) / x(21) - NOTES:Ili _ C !': 'll I 1 I j I . I I , 1. NUMBERS SHOWN IN PARENTHESES,,(NU ADJACENT TO LIGHTS 4 ( 21-.::::.=$,-.,..1:4 , '(25) rr (25) / /p\ EL 11 J_ - 1 IT, d NOTE 4 :1 `NOTE 4 , ,� AND PROLVIDE#12000NDUCTORS FOR 15A OR .� - '�xs' ■ . NOTE 7,TYP `(11 7 5ACU8001 20A CIRCUITS LESS THAN 75 FEET DE#10 CONDUCTORS .• • I= m< -�,:;- - _�,,.;- ').m Al— r� FOR CIRCUITS GREATER THAN 75 FEET.VI KK ■ 1 1H ,„1111 _t =� m� I -` 2. COMBINE RECEPTACLE AND LIGHTING CIRCUITS IN A SINGLE ` ,---. --- -. ... - - ` �` _ CONDUIT TO MINIMIZE LENGTH OF CONDUCTORS AND CONDUIT. K1 1; - u-= 1 _1 - - 1 I ilI I ,1 ,• =�.'I / t I CIRCUITS COMBINED INTO A SINGLE CONDUIT SHALL BE SIZED I II h r p € € 1 I r h �I (t 0 „k& 17{) GFCI FOR NEC DEBATING AND CONDUIT FILL REQUIREMENTS. -._ - `�` 3. MO TOP OF RECEPTACLE 6INCHES BELOW TOP OF PARAPET (21•Z NOTE8 - •I= :d 11 __.., _ E � 0 =�J == i WALLY In T-STAY(FOR S --,•-•-•,- - ...__... F Er:-.. -_._ ...�F.-j -/- 715MAU8001 11. I f[ G I �' �� 4. CAPPEDEFOROFUTURE CAMERA.UP THROUGH FLOOR SLAB AND N r, -.1 / I c -.'�c..�� 24HR „'.fir a1 61)1) w A.--_- S. WALL MOUNT EXTERIOR LUMINAIRES 8'-0'AFG,UNLESS OTHERWISE •f Iltl a1L 411 -�_-°. 1 It'llt ' II Al Al� `` NOTED. �� 111111111111111 ' `� 1- 715EF8001 muumuu' Iluu I ' II ��`I O Olt ("1 -Ii:1I3113 (25) NOTE 9,TYP i - - - (255) 1 II . 0 6. WALL MOUNT LUMINAIRE AS HIGH AS POSSIBLE ABOVE STAIR LANDING.•715HWS8001 %� - - - 7,IU11191t9 /!-/ --- �° - (21) (2 7. SUSPEND LIGHTS IN THIS ROOM 9'-0'AFF,TYPICAL. --- _-_�.._- / / rt=- \ 8. WALL MOUNT WEATHER PROOF SWITCH FOR CONTROL OF LUMINAIRES h - (25) X1 - 5 / (45) I I ,II T-STAT(FOR LEADING TO TOP OF TANKS. 715AHU 0 . ._ _....._ o 65 ( .1 K1 1-1 T 'Pri .... J T -1- �)i ==7-;:- _.-__S 9. MOUNT LUMINAIRES AS HIGH AS POSSIBLE IN THIS ROOM,TYPICAL.0.1 w — "'I -N, - _ --'- - 10. PROVIDE 120V,SINGLE PHASE STARTER FOR SUPPLY FAN.CONTROL F - _-' VIA T-STAY. -A, -4I- 7-1-----"--44 oa WP/GFCI a NOTE 5,TYP En ai PLAN o of a PRELIMINARY W, DRN: JNH DATE, CLEAN WATER SERVICES SHEET TIRE ET XX OF_XX DWG " DSN: RSH DWG* 715-EF-140 BROWN GREASE RECEIVING FACILITY PDT NOT FOR w THIS BAR IS �1--_�i7 _ CH2M H I LL DURHAM AWWTF APR 2013 CONSTRUCTION I CHIC JKL "°`"E' ONE INCH WHEN �Cd11��dLIGl ►�CV1CeS PHASE 5D2 ELECTRICAL k 715-EF-140 i 715 EF-140 422389.dgn DRAWING IS Our commitment L else. FACILITY FLOOR PLAN XXXX -, A�LLC SCALE AS SHOWN FULL SCALE. COGENERATION AND BROWN AND PARTIAL TOP PLAN cws LL REV, DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hiestwro,Oregon 97123-9379 GREASE RECEIVING FACILITIES PR,« X77 ENGR STAMP: • •• •• •• • • • • •• • • •• • • • • • • ••. ... • • • • . •• •• • • • ••• • • • • • • • • •• FE640X f) [C1] 7` [P3] 715994402 1A11 715LCF 401 [C1] [A1] 715LCP6401 [Al] 715LCP6401 480V,3PH 7176401( !� ® LE640X ® ® • • FIT6�OX. /) • ••° LIT640X • • • • • • • • •• • • 4 •. • • • • • • • • • • •• •• •• •• •• • I P 21 •• • • • • • • '• ••• • [C10] 715LCP6401 [A1] • ® TIT660X i0 •• •• e•• • • IP21 715194401 • • 208Y/120V,3PH • • • • • ••• ••• •• • • • • • ••• • • OPEN/CLOSE FLOW VALVES TEMPERATURE INSTRUMENTS WASTE RECEIVING TANK LEVEL FOG WASTE FLOW INSTRUMENTS NTS X=1,2,4,5,7 NTS X-1,2 NTS X=1,2 NTS X=2,4 I 715V®6403 [C61 7151®6401 [C1] 1 FE640X 0 � [Al)[A1) 715LCP6401 SV6405 e•\ [C2] 7151 6401 ® 715V®6401 [P3] 715994401 FIT64OX 480V,3PH [C12] CP2I MELTRIC PLUG/ ' [93] DISCONNECT [P2] 715194401 II [P2] 715194401 SV6406 !� [C2] 715GN0640X 0 715LCP6401 208Y/120V,3PH 206Y/120V,3PH ® I FOG WASTE RECEIVING PANEL FOG FLOW INSTRUMENTS SOLENOID VALVES FOG WASTE GRINDER 1&2 NTS NTS X=1,3 NTS NTS X=1,2 I MELTRIC PLUG/DISCONNECT I [P3] 715HW56401 r[933] A2 715LCP6401 715P660X r 715MCC4401 FCV660X 0 [ ] 715MCC4401 0 [P3] _ 715994402 ® 480V,3PH ® (Cl] 480V,3PH FV640X 480V,3PH [C8] I v [C4] [P2] [C10] [A2] 715HWS6401-LCS 715P660X-LCS 715LCP6401 715FV640X-LCS r[C10] 7151CP6401 IP21 208Y 120VV, ® • • ,3PH I 2 HIGH PRESSURE HOT HOT WATER RETURN SECONDARY HEAT OPEN/CLOSE oi WATER CLEANING SYSTEM FLOW CONTROL VALVES LOOP CIRCULATION PUMPS 1&2 VALVES WITH REMOTE CONTROL w N I S NTS X=1,2 NTS X=1,2 NTS X=3,6,8 I- 0 O a [P2] FIT6601 [P2J 715194401 g FE6601 [C1I 715194401 208Y/120V, n IS PDIT6601 ® di 9[Al] , r[Al] • 9176601 ® 0 [Al] 9 0 o_ ® Al 715LCP6401 TIT6601 [All ` 1116602 ® 0 [Al] cri I C l_ _ 0 SECONDARY HEAT CO DI LOOP INSTRUMENTATION Io NTS X=1,2 Di• ORN JG CLEAN WATER SERVICES SHEET TITLE: SHEET: OF:xx OWGe: PRELIMINARY BROWN GREASE RECEIVING FACILITY NOT FOR DSN: RSH OWE' 715-E-601 DURHAM AWWTF �T APR 2013 CONSTRUCTION THINCHWH CH2MHILL DATE: Di � `�� ELECTRICAL I w• GNK aoF�r. ONE INCH WHEN Cli CSIIWd�CI JGIYIIA PHASE 5D2 CABLE BLOCK DIAGRAMS PLC r. XXXX 715-E-601 z 715-E-601_422389.dgn DRAWING IS Oar commitmentieelaar COGENERATION AND BROWN • APPD LLC SCALE AS SHOWN FULL SCALE. T. REV cws DATE BY OPTS DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES PRJSt 6471 ENGR STAMP: • • •• •• • • • • •• • • • • • • • • • • • • • • • • •• • • • • • • ••• • •• • • • • MELTRIC PLUG/DISCONNECT • • • • • • • ••RAELTRIC PLUG/DISCONNECT © 1P31 © [P16] 715P640X 715P640X MELTRIC PLUG/DISCONNECT MELTRIC PLUG/DISCONNECT [C121 715MCC4401 7480V,3PH 480V,3PH • 715P660)( © 1P3J 715MX640)( © • [P16] • • • • 0 • [ 1 ••715MCC4401 7480V,3 401 • • •• pfH6a0X• • •- • 715P660X-LCS • • • • • • • • • [C12] [CSJ 480V,3PH [C8] 480V,3PH ® [C14] • • • • • • • • • • • ••• ••• • 715P640X-LCS [C10] • [C10] [C101 715LCP6401 ® 715LCP6401 [C3] TSH640X ! .• • •• • • • • •• .'. >r • • -• • • • • • • • • • ••• • • •• • •• • • • ... •• •• • • •• •• • • • ••• • • • • • • • • • •• I ELECTRICAL PANELBOARD SCHEDULE I I ELECTRICAL PANELBOARD SCHEDULE I • • • • ••• • • • • • • • • • • PANEL:715PP4401 LOCATION: BROWN GREASE RECENNG FACILITY PANEL:715LP4401 • • •• • • • • • • LOCATIN: BROWN GREASE RECENNG FACILITY . VOLTAGE:480 VAC.3 PHASE,3 WIRE MOUNTING. SURFACE,NEMA 1 VOLTAGE:2087120 VA 13 P=,AS:4 DIRE • • •• • • MOUNTING: SURFACE.NEMA 1 BUS SIZE:225 AMPERES • FED FROM 7154754401 BUS SIZE:1004 FED FROM 715X FMR4401 MAN SIZE? 150 AMPERES MAN TYPE: BREAKER MAN SIZE: 100A • • • •••• • • • MAN TYPE. BREAKER SCCR 30000 SCCR 10 000 BREAKER LOAD,VA LOAD.VA BREAKER 1 BREAKER LOAD,VA LOAD,VA BREAKER CIRCUIT TITLE CKT PHASE PHASE CKT CIRCUIT TITLE CIRCUf1FRLt ••• •_1'CKT • •• •-6 PHASE PHASE CKT CIRCUIT'RILE NO AMP POLE A B C A B C POLE AMP NO. • • • 440• AMP.PA.E•A• B C A B C POLE AMP NO. 715GRD8401 VIA715VCP8401 1 X 20 3 1328 1660 3 20 2 715AHU8001 • •�� RCPT-ELECTRICAL ROOM• • C •20 •108Ir 200 1 20 2 FOG HEAT EXCHANGER 1 THREE WAY VALVE• FOG WASTE GRNDER 1 3 - - 1328 1860 _ - 4 - RCPT-MECHANICAL ROOM. • • • lu ,•20• L • . 540 '.. 200 1 20 4 FOG HEAT EXCHANGER 2 THREE WAY VALVE 3 HP 5 - - 1328 1660 - - 6 - RCPT-PUMP ROOM • ••• _ • 51 •20• e •• 900 200 1 20 8 FOG HEAT EXCHANGER 3 THREE WAY VALVE__ 7156R06402 VIA 715VCP6402 7 20 3 1328 498D 3 30 8 715ACU8001 RCPT-EXTERIOR 7 20 540 500 1 20 8 715LCP6401(PLC) FOG WASTE GRINDER 2 9 1328 4980 - - 10 - RCPT-ROOF 9 20 360 1000 1 30 10 715LCP6401(PLC) 3HP 11 1328 4980 12 - SPARE 11 20 200 1 20 12 715SF8001(MECH ROOM EXHAUST FAN) LTS-SITE LIGHTING 13 20 2 512 580 3 20 14 715MAU8001 SPARE 13 20 100 1 20 14 715UH8001(MECHANICAL ROOM UNIT HEATER)• 15 - 512 580 - - 16 i. SPARE 15 20 200 1 20 16 715VCP8403(FOG WASTE RECENING PANEL) SPACE 17 580 - - 18 - SPARE 17 20 50 1 20 18 F116401,FIT8403 SPARE 19 _ 20 3 3 20 20 'SPARE SPARE 19 20 50 I 20 20 FII13402,FTT6404 - 21 - - 22 I_ LTS-ELECTRICAL ROOM 21 20 410 25 1 20 22 Ff6601 23 - - - - 24 I. ITS-MECHANICAL ROOM 23 20 273 300 1 20 24 FCV6601,FCV8802,(FCV8803,FUTURE) SPARE 25 20 3 3 20 26 (SPARE LTS-PUMP ROOM 25 20 777 50 1 20 28 715LCP8001 27 - - - - 28 I. LTS-EXTERIOR 27 20 565 3000 1 30 28 715HWS8001 - 29 - - - - 30 I_ SPARE 29 20 100 1 20 30 '715NIP8401 SPARE 31 20 3 3297 3 30 32 1715154401 SPARE 31 20 1 20 32 SPARE 33 - - 6300 - - 34 VLA 715)•MR4401 SPARE 31 20 1 20 34 SPARE 35 - - 2023 - - 38 I- SPARE 35 20 1 20 36 SPARE -715PP4402 37 50 3 2400 3 20 38 'SPARE SPARE 37 20 1 20 38 SPARE 39 - - 2400 40 I- SPARE 39 20 1 1 20 40 SPARE 41 - - 2400 42 - SPARE 41 20 1 20 42 SPARE TOTAL LOAD 3168 3168 2656 7220 7220 7220 TOTAL LOAD 2397 18751 1173 900 4425 850 PHASE A LOAD(VA)• 10388 PHASE A LOAD(VA). 3297 PHASE B LOAD(VA)• 10388 PHASE B LOAD(VA). 6300 PHASE C LOAD(VA)• 9876 PHASE C LOAD(VA)• 2023 . TOTAL LOAD(VA)' 30652 TOTAL LOAD(VA). 11620 I ELECTRICAL PANELBOARD SCHEDULE PANEL:715PP4402 LOCATION: BROWN GREASE RECENNG FACILITY VOLTAGE:480 VAC,3 PHASE,3 WIRE MOUNTING: SURFACE,NEMA 1 BUS SITE:100 AMPERES FED FROM: 715PP4401 MAN SIZE:50 AMPERES MAN TYPE: BREAKER SCCR:30,000 BREAKER LOAD,VA LOAD,VA BREAKER CIRCUIT TITLE CKT PHASE PHASE CKT CIRCUIT TITLE NO. AMP POLE A B C A B C POLE AMP NO. 715FV8401 1 20 3 300 300 3 20 2 1715FV8405 3 - - 300 300 - 5 - - 300 300 - - 8 I- 715FV6402 7 20 3 300 300 3 20 8 715FV6406 9 - - 300 300 - - 11 - - 300 300 - - 12 - 715FV6403 13 20 3 300 300 3 20 14 715FV64W 15 - - 300 300 - 17 - - 300 300 - 18 - 715FV6404 19 20 3 300 300 3 20 20 715FV6408 21 - - • 300 300 - - 22 - 23 - - 300 300 - - 24 - 5. SPARE 25 20 3 3 20 26 SPARE N - 27 _ - - iu - 29 - - SPARE 31 20 3 3 20 32 SPARE Iii - 33 - - - 34 I- - 35 - SPARE 37 20 3 3 20 38 [SPARE o 39 - - I- a - 41 - - - - _ 42 (- TOTAL LOAD 1200 1200 1200 1200 1200 1200 PHASE LOAD(VA). 2400 PHASE 8 LOAD(VA). 2400 PHASE C LOAD(VA)• 2400 t1 0 TOTAL LOAD(VA) 7200 N W Q 0 F O -I O. C co a of 00 CO N N ,rI o NI 06 JG oRre SHEET GREASE RECEIVING FACILITY SHEET: 0W0 PRELIMINARY ■ CLEAN WATER SERVICES xx NOT FOR • OSM RSH DWG►. 715-E-620 c�` Y DURHAM AWWTF ELECTRICAL e`c'T APR 2013 CONSTRUCTION THIN BAR WHEN CleanWater set Vice CH2MHILL H I LL PHASE 5D2 ��r 715-E-620 W PANEL SCHEDULES CAD FILE t. ONE INCH WHEN CHK JKL 715-E-620_422389.dgn DRAWING IS O•rcoavtsntIuele COGENERATION AND BROWN • A�:LLC SCALE AS SHOWN FULL SCALE. DESCRIPTION 2550 SWHilsboraH V. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES R i 6471 ENGRSTAMP: ` LL REV/ DATE 8Y APVR . •• •• •• • • • • •• • • • • • • • • • • • • • • • • •• •• •• • • • • • ••• • • ••• • • • • • • • • •• • • • •• • • • • • • • • •• . . .11— ••• 44 s\o„. - s rzs—: • • • • • -• -- ___ AUXILL INA NCLOSURE POKER;_• • •_ •_• • • • __-_ COOR�INA WITH ENCLOSU( • - i•• ••• •(0 /PRoDERFoRcoNNEcoN1oc:TIo: -- POSH8002• J1 ,Ji 716FAN4501 • • 7,6F/W4502 • • • ••• ••• •J`.. .... ". ,,,_am. ! 0 I 718SF8001 716SF800$ I I I ! 1 ( 7165F6001{ © I w le- ,, ', less -- s:>GII Lll- __- �..�. ., ;... 5 �.• I NOTES: _"g -. _ ,�,.,• -- -------- --------- I 71611Gµ4102 1. STUB UP AND CAP SPARE CONDUITS FROM 716LMH0101 = - • ��• I AT THIS LOCATION. MID �r �w s, ----_—:::a,-, TE4502 ' ' I r BSC 4 j /0 BSC 2. PROVIDE CONCRETE ENCASED MAIN GROUNDING TE4501 I I' G-- j ii ..''G - ELECTRODE,#4AWG BSC,LENGTH AS SHOWN. G- G----- _ S4 BSC,UON. 776TCP4501 H II ® 1 .',I i�hL. .! a .•. a�\, I I 716FAN4501-LCS H I I �i .,, �y�:_�_,I 3. DISCONNECT SWITCHES MAY NOT BE SHOWN IN PLAN - _FS I I * 1 ,; : I 14, * VIEW,BUT SHALL BE PROVIDED AS INDICATED ON I 'rl- CABLE BLOCK DIAGRAMS AND ONE-LINE DIAGRAMS. I ,r - ._ 1 EXO I ! i�Ci�rm.�7ala�:=>OQI'--7i n 10�� I• I I CONK TYP -7= 'T_ ROUTED EXPOS ABOVE THE FLOOR SHALL BE I I ,• - r ^ __ _r -4� I�I .� POSSIBLE.OONDUBT ABOV L� .,.� _ R SLAB WHERE � 11� ,Fi�d.0�y� .... h --- 1 a �'�rj! ;I�� -- �°l'I IM: �'k -. ..fix' EXPOSED,O 1 1 O MI, - `, !.. _ _ yypl Y RC f!I :_t I ] I I I __��Il►',��♦� !1.r, `I ��\ J —� -4 5• - G - G-r �ll • µMI J 716TIT6601 4 I -_I NOTE 9 I RI .( I I Y '-/\ /\ r" \- 1�1 6 NATURAL GAS AND DIGESTER GAS TRAIN ASSEMBLIES. BU SOU T , I ASH8002tABOVE) I ' 71.EF8002-LCS:- , i _ k:4 ,1 ms 1.1 I 1 . 716EF8001-LCS I - ---)- - ' 5 r i 1 _ ! � � 7. PROVIDE[1 1C,1#410]FROM GENERATOR NEUTRAL MI $R TBSU BELOW ® _ 7T .v ! 0 1 * BAR TO NEUTRAL GROUNDING RESISTOR. I 7I6XFMR4401A BU UST i LIT4505 ` I I UT45o6- rrl /\ : 716NGA4501. I I• ` r,],OTE 1 I r I I • . 8. STUB UP 6'MIN.PIGTAIL FOR FUTURE TRANSFORMER ,yy :_ . I _ NOTE 7 I '-. �_ HEATEµ, I I 716DCA4501, ' ' NOTE 7 I ` - - { �� GROUNDING CONNECTION. I I NOTE 12 I \ I I �l.il {_= I l4/. ,. _O ` NOTE 6 I ----_- - I I I `\ I( '' .4 --I •XFMR4402 --- \:A r i ' 9. BOND TRANSFORMER NEUTRAL BUS PRIMARY SIDE) ` _ ! - i 6SC _ I Iii ' ` ..•� ■ p 71•_ TO GROUND BUS INTERNAL TO TRANSFORMER. i I I 1 716P4501-LC$ I p6TDE g 45 - NOTE 6 � 10. HEAT TRACE INDICATED EXPOSED PIPING FOR MI I & 716P6601-LCS i /\ "„ 7 •4�.. I�Ii I � f 0 FREEZE PROTECTION CONTROL WITH AMBIENT [ 71.MC 0 , I I I ® THERMOSTAT MOUNTED ON BUILDING WALL. r\ 716P6601 I �,` y �� 716P.. -LCS 71 P6602 3k I �_ I` , 71 LCP8501 �, /\ 7 ', . 11. CONDUIT NEAR THE ROOF SHALL BE ROUTED TO AVOID•0 �: O , i _ /\ 16P4502 /'� `�1,` NOTE 5 _ I /\ 16P4504 THE MAXIMUM TRAVEL PATH OF THE BRIDGE CRANES. I I it _d6;4502-L i\ AIT8501 ,1,` , L9 �716 I 12. COORDINATE WITH BUSDUCT MANUFACTURER FOR 1716SWGR4401 , P4504-LCS 1 FIT4504(ABOVE) - COORDINATE WI BUSDUCT H WP _ '- r ,L '0±14"---,\, 1 , P5450 f I FIT4502(BELOW) I I @ ' EATER CIRCUIT. ]____ 1 I !�i L:r�'i 716P4501 ` ELC L;�„ I , ' '718`(? 01 /\� I I.!' 1 PS4501 _716GEN4501 j - t6,07 ����� r lk 71�.- 1 3 71•. ��J o 716GEN4501 - (g OOVE) 1,i1' c, t=-� If=lf 4 I'' I 716GEN4502-LCS( W) I 716P 507,∎i.. II-II i <i,I 1 PIT6601 4414 - {' pIT6602 ill I ( ! 716GEN4501-JB 17•CP640 ® "I ® �nl; r• 716GEN4502 J8 T a O ® 716VCP4501(BELOW) ) `,h. , 716VCP4502(BELOW) i rL�o . 1 i I,�1` 716P4506 ;:. T 503 ABOVE LIT4507 1sD asol . .►\ LLL49 v .,-iI} .._. \\1` .- FIfT4501(6506 W)w ( I /\ \\1� ®_,► 716P45os®Ali4501 t`:ID J' II F. .`��! LLH4 o — . _G----, I I { i� - -- `G-- `,1, I Zii°0 ® A-NOTE 10• + : 10 B C ( I �, 7 6P4507 L a , i I Yr : ' 'II7-31 ' 4 / YI ��_ FAG Y ;T. 1.P4 d.‘- ' Y • Bt11SiDUCT J I , Yr �� - J _. �r�r.��� '.J- -/V/�/\ O 716X MR4401B 1 1 I _:� G--- a. ---G G-2 ff.....G _-G- -G- = G- y ?J I ---- I (FUTURE) -----, 1----+a I / /p�(p�� 1- 501- / j\s T. N I I I I / HS4502 J �.• I w I II I / 1 ♦--ri- -G- GI----• / O I I I I NOTE 8 I / --'` -_ p I II I /I II O a I I I t._ s. i / O I I I i)._ t i---1 I / rn I .- -k.....��y--� I / -----G G----- � 3PROCESS PLAN ez �I w DAN: JNH °R'D CLEAN WATER SERVICES SHEET TITLE: SHEET:xX OF:xx DWG* PRELIMINARY V DATE: COGENERATION FACILITY NOT FOR■im DsN RSH Dwck 716-EP-141 DURHAM AWWTF ELECTRICAL DATE. APR 2013 CONSTRUCTION w THINCHWH CleanWater Services CH2MHILL PHASE 5D2 716-EP-141 CAD FILE-. ONE INCH WHEN PROCESS PLAN PLC• XXXX CHK: JKL 716-EP-141_422389.dgn DRAWING IS Our romenibae•t u c1Car COGENERATION AND BROWN Z M'PD:LLC SCALE: AS SHOWN FULL SCALE. REV 1, DATE RV APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 971239379 GREASE RECEIVING FACILITIES k 6471 ENGFSTAMP. I • •• •• •• • • • • •• ••• • • •• • •• • •• • • • • • • • • • • • •• _•_.---... •. • • _-_ • .._..--- • • ••• • • • • •• • • • • • • • • • • • • • •• •• •• •• • • • • -- • ••• ••• •• •.. ••• • • •• •• • • • •• • • ••• ••. - R 99 1 _ • ••• • •I • .I •. • 1 I 1 I 1 II 1 II � I 1 \I\ 1 11 ' II I � I I i Fom OA =11 _-- DI r ! I IJ 716ACU:11t�� I NOTES: ice, —�I m I -, •i\ I 1={T -. - - - ' I 1. BRIDGE CRANE BUS BAR CONNECTION. COORDINATE ,N � _#I■" I CONNECTION WITH SUPPLIER. - �� I!� a ! 2. PROVIDE JUNCTION BOX IF REQUIRED FOR PROPER MINI Ii 1 CONNECTION TO BRIDGE BUS BAR(ABOVE). II I I WALL MO T K1 = ,'�I 2 I 3. NUMBERS SHOWN IN PARENTHESES,(N),ADJACENT TO 15) II g'-o AFF I I_I (15) LIGHTS AND RECEPTACLES DENOTE CIRCUIT NUMBERS IN - CI b 1 I (39 ... ''� -, ----------- PANEL 716LP4401.PROVIDE#12 CONDUCTORS FOR 15A OR Is- - - -`* I I I ( )���� /GFC�I�I,i__ CONDUCTORS FOR THAN 75 FEET. PROVIDE#10 20A CIRCUITS LESS �,i,� ., ��- C1 • ■��mm�:Iwr•1r,1 1_m•.�f•Im1�.� TS GREATER THAN 75 FEET.ST-Y I I 1�'t����- --.! - - _ .. J11611I�--'1 -. , (1 ) -- i'135) '{' 11�3�- r_ ---n)p moI 1� 4. COMBINE RECEPTACLE AND LIGHTING CIRCUITS IN A SINGLE-Rev_-_ :R' - I r + ::Z I, •' r� 1 ( QI r /, Al NO ` i�1!7, O(35, �_.�J 5. POWER FAN FROM RESTROOM LIGHTING CIRCUIT AND ■ I '---- _ +}} ♦ CONTROL VIA LIGHT SWITCH I .. ae::�::. : .' i NOTE 5 •(13)_ .' .......,..^„1121= ",f �u><' �1• - - _ li1y- " pmi..1t �l 6. CONDUIT NEAR THE ROOF SHALL BE ROUTED TO AVOID - - ' '- THE MAXIMUM TRAVEL PATH OF THE BRIDGE CRANES. 4YORK o,- _ $ I1 - I I I 1 r t I •�' f i l<{. +(35)� \31 Yr UN ___ 1i �' I I I I I At.11,„ca.=-g 81 Ki 7. SURFACE MOUNT LUMINAIRES IN THIS ROOM BETWEEN L 1� all _ • i! {1 / I I BEAMS,TYPICAL FOR ALL. al ,■. ✓ 1 1 ,- ___ ant I MOUNT �' - r- -1 ji -Irr�*,n n E 9 r 6•Ark 1°�1 L -( "'T �t R( 1(1.3)1 _ .. F # ..4.= O•�d. ` _i3 1 (39) 8. SUSPEND LUMINAIRES IN THIS ROOM 9'-0'AFF,TYPICAL. ■r _ '...._._ I�w►I _ �r• I I _ i 1 Al i ir i1 II ii •.11 1 9. WALL MOUNT LUMINAIRE AS HIGH AS POSSIBLE'VII N' �,� .-- _-{-_- ( - •.1 +"; 10 MEZZANINE LEVEL. (15) B k (II 3 = ( ( h,t• •Ir+11� ��. 1 WP/GFCI �1� ('t (1.3) I t . CONTRACTOR SHALL MOUNT TWO TYPE Al LUMINAIRES I - L.:. C �L.iIC� i �1 ,I._ -' `„. _ % ■ �c��. +I� ,!■ " WALL MOUNT IN THE SECOND FLOOR ROOM ALLOWING ROOF ACCESS. JI 71 J'3 1 11'� \�� _YJL' F a� -- y \`1 (1 ) [ - 9'-0'AFF U THESE LUMINAIRES SHALL BE CONTROLLED BY SWAY WALL MOUNT 711 1, 1 I {I:I �� I� `fir ) 1 I T 1` Ilf I xi ��� 1SI SWITCHES MOUNTED AT THE GROUND FLOOR AND SECOND 1 r :• AT FO- _ n r-t: P ! i 1� J -• I 7 _ T-0'AFF •Zt29-- '1111.t�.- 6 j I 1 I ,=r:YSG8b6 ►`1 1 1747)-I �1♦1�6L! - } FLOOR.CONTRACTOR SHALL ALSO MOUNTATYPE Kt ! �. - a - LUMINAIRE ON THE EXTERIOR CENTERED ABOVE THE MAIN ,I': r I R a... J 1: bf,. :, %� 1 At 17,:.,1 d u..n,.• r$3 t t... a (15.:!I / I Ili W -f•� S I j c ) DOOR TO THE ROOF.THIS LUMINAIRE SHALL BE SWITCHED 1 I I ',•I �■ ® . -.. � A � . ;►� WP/GFCI FROM-INSIDE HEROOM. ` ! i �(27) (2 ) �- (1 �1 ,' 11. SWITCH FOR ONTROL OF LIGHT ON THE SECOND FLOOR. + RI 1 -i ,3......--------- '- I'.. It I ',!I ; �. ! ;=:- ..�---- - '1L�iP�R---- y I-II 1 �, A7 'i - -— o-o• D_ Win 7 7 R I, ` �� R�u,;l - 7 `:,..••• ... rti I� v - I (`�.r:) (9 I (29 I ►` (2I�- I i�:-11 , I•`,,.I,F `* Ir- Ir NOTE 7,TYP N TE2 ' i `��� N• y - _ _._ - -_____ N i - W i 7;O jr. I_ MIA _ '''""Erin.11 O_�' f ._.. TMP I 10 i I ■ • ,` O NOTE 7, � rt[z l'.� i9sHOlsT:2r �1 • \N l 111 �� ,!��I IN_ 11 - O 7` NOTE 1 1 �� OTE 1 + ra .I. $ - --- '1'05) - ! I M "---- ---- WP/GFCI I I 716UH8003 ea 391_; 1 uJ WALL MOUNT I 1 Q 8'-0'AFG,TYP I I ° I I p I I J D ti s! v N FACILITY PLAN v1 3/16•=1'-0' Cisz I SHEETTTRE: SHEET: GF: DWG.: PRELIMINARY • DRN: JNH CLEAN WATER SERVICES COGENERATION FACILITY NOT FOR ▪ DSN: RSH MG. 718-EF-141 DURHAM AWWTF pq°E. APR 2013 CONSTRUCTION ni CH2MHILL PHASE 5D2 ELECTRICAL 716-EF-141 THIS BAR Is M�n�jl�r c �_M CAD Fl�. - ONE INCH WHEN l�l ♦V- Jei ices z oar JKL 716 EF-141 422389.dgn DRAWING IS 0•r commitment in dear FACILITY PLAN PLC T. XXXX COGENERATION AND BROWN J APPD:LL(', SCALE AS SHOWN FULL SCALE. REV. DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES XI 6471 ENGR STAMP: LL I _• •• ••_ ••_ • • • • •• UNIT SUBSTATION UNIT SUBSTATION • • •• •• • • ` • • 111, • • 716XFMR4401A 71BXFMR4401B ••• • • •• • • • • • • • • • • • • • • (FUTURE) • • • • • • • •• [A15] TE4501 !t •_ 716TCP4501 [P2] + - - ---. :--. 100 13.2KV,3 02A 100SWGR0102@ (EXST) (EXST) tat= ® 716DCP4501 TE450Z �� 13.2KV,3PH 13.2KV,3PH ••• • ••• • • •• • ` `'-' (,G3,�; _---_ • • •• [62]• • •• • • •• 716LP4401 -�4000A BUS DUCT 4000A BUS DUCT -_1 J. ' [al [C) HS4502 �• • • • • j16DCP4502 • • • 120/208Y,3PH (FUTURE) ,"--]716GEN4503 EXISTING MANHOLE • ••® ••• • [A15) — __,)(FUTURE) NEAR 100SWGRO102 CIRCUIT CALLOUTS: 7E4503 .) -I 716TCP4502 [P2] — --i 716LMH0101 (THIS DETAIL ONLY) ® 6SWG401 -Q1 [bl [d] [a]= [4"C(EXST),3#2(15KV),1#2G(600V)] ••• ••• • • •• •• 7E4504 !t 71 R4 480V,3PH `3[CE-7] [4"C(EXST),PULLCORD1 • • [Cl 716MMH010$ • • • [Dl @' [4"C,PULLCRD]#2G(600�] ENGINE EMERGENCY STOP TEMPERATURE MONITORING Gt d-[a) 0 [b] ,•. [dl [c]= 2[4"C(EXST),PULLCORD] NTS NTS 718MMH0101 [d]= 2[4"C,PULLCORD] 716GEN4501 [alb 716GEN4502 716MCC4401 IN - [d] 480V,3PH 1 [C2] MELTRIC PLUG/DISCONNECT-IF I ei-Ib1 @1-..,,, r I [I I- PS4501 ® PS4502 ® 716DCP4501 ® [P28] 7P1 716FAN450X 0 480V, HI 1.UNIT SUBSTATION UNIT SUBSTATION ��JJ (C2J 718XFMR4401A 716XFMR4401B PS4503 ® Q/ 716D®4502[ C8l (FUTURE) 6/ [Al] 716ATS4401 PS4504 480V,3PH 15KV SWITCH ® 716FAN45 -LCS 0X CLOSE-COUPLED 716TCP450X TO TRANSFORMER ® dr @' 13.2KV POWER DISTRIBUTION [1"C,3#6,1#1061 NTS 716PP4401 7,sxFMR4402 RECIRCULATION PUMP PRESSURE ENGINE RADIATOR FANS 480V,3PH 480V-208Y/120V A\ NTS NTS X=1,2 3PH FE45QX [C1] [Al] 716LCP4501 [11/2"C,4#1,1#6G]- FIT450X 0 - ® CIRCUIT TS; 716GEN450X-JB [CE-2] NOTE 1 DETAIL ON LY) [a]= 2[3 1/2"C,3i1600 KCMIL,1#1/OG] 716LP4401 (P2] 716LP4401 714�1C 304407 208Y/120V 120I208Y,3PH E-1 [b)_ [1 1/2"C,3#1/0,1#6G) 3PH JB [C]= 3[4"C,3#GKCMIL,1#3/OC] PUMP W AND HEATER) [C14] LOW VOLTAGE POWER DISTRIBUTION GAS FLOW METERING 718G®454X NTS NTS X=1,2,3,4 [C2] 716DCP450X I FV 71 716VCP450X ® [P2] [PZ](SPACE HEATER) a [P21 716LP4401 208Y/120V,3PH [P2] [P3](BATTERY CHARGER) in o PSL �� 0 - [1"0,8#14,1#14G] a 716LP4401 716GEN450X-LCS 120/208Y,3PH H I- FCV /N NOTE _. 716SWGR4401 1. DIAGRAM IS TYPICAL OF FOUR GAS FLOW I CONTROL ASSEMBLIES(TWO FOR NATURAL [C2]CON"COMMAND FROM (77- [Ai] 716MCP4501 JACKET WATER PUMP BUCKET) FLOW CONTROL GAS,TWO FOR DIGESTER GAS:716NGA4501, ASSEMBLY 716NGA4502,718DGA4501,716DGA4502) AIT4T 1 ® [Cl) 716PP4401 N 480V,3PH w X ASSEMBLY 1 716NGA4501 AE4501 O 2 716NGA455002 c i_[Al] NOTE: STAB UP AND CAP CONDUIT IN ELECTRICAL ROOM a 2 716DGA4502 ALONG WEST WALL. 716VCP4501 716VCP450g c) ® ® cri N GAS FLOW CONTROL CH4 METERING ENGINE GENERATOR AUXILLIARIES NTS X=1,2 �I NTS NTS I Er _6 ORR JG a,E, CLEAN WATER SERVICES SHEETTRE. SHEET ( °`'�(�( O"G`: PRELIMINARY r GSM RSH DWGA 716-E-601 COGENERATION FACILITY APR 2013 CONSTRUCTION THIS w THIS BAR IS [�J � c - /� DURHAMAWWTF ELECTRICAL �°E I Q 716F E-601 422389.dgn ONE INCH WHEN - C9eanwaeer Services CH2MH I LL PHASE 5D2 716-E-601 Lu CHK JKL °` ` CABLE BLOCK DIAGRAMS = XXXX z DRAWING IS Our ceuBU�e•tirelar COGENERATION AND BROWN L uc SCALE AS SHOWN FULL SCALE. �. Oregon GREASE RECEIVING FACILITIES A k LT- REVS DATE BY ARA DESCRIPTION 2550 SW Hillsboro H Hillsboro,Or on 97123-9379 ply^ 6471 FNGR STAMP. • •• •• •• • • • • •• •• •• • •• • • • •• AMBIENT THERMOSTAT ••• • • •• • • • • WITH CONTACTOR • • • • •IEPf TRACE ROWER • • • • • • CONNECTION KI• •• MELTRIC PLUG/DISCONNECT MELTRIC PLUG/DISCONNECT MELTRIC PLUG/DISCONNECT 3 3 r r 716P45O © 7 ] 716P450X © (P3] m I . FRESHOIL TRJR 716P450X © 1 716MCC4401 716MCC4401 716MCC4401 • • • • • • • •• [C8] 480V,3PH [C8] 480V,3PH • •• • • • • • • [C7] 480V,3PH e • • • • • • e •2r • • • • • • • • • ••• HEAT TRACE EXPOSED PIPE, r[C10] SEE PIPING SCHEDULE o 716P450X-LCS 716P450X-LCS 716LP4401••• ••• • • •• •• 716P450X-LCS 716LCP4501 208Y/120V,3PH• • ® ® • • • • • ••• ••• •• • • • • -- - ---' ••• • • LOW-TEMP RECIRC PUMPS HIGH-TEMP RECIRC PUMPS FRESH OIL TANK HEAT TRACING FRESH OIL TRANSFER PUMPS NTS X=2,4 NTS X=1,3 NTS X=1,3 NTS X=5,6 MELTRIC PLUG/DISCONNECT © [ ) PIT6601 0 716P660X MELTRIC PLUG/DISCONNECT 716MCC4401 © [Al] 716LCP4501 (Cl]` 480V,3PH 716P4507 er(P3] LIT4508 0 r O 716LCP4501 716MCC4401 7176601 r% r ® r[C4) 480V,3PH (Cl] dr[C10)r[112] T1T6602 0 )C6) 716P660X-LCS 716LCP4501 LLH4508 !� [P2] [P2) 716LP4401 ® 0 P1T6602 c7 716P4507-LCS 716LCP4501 208/120V,3PH ® ® HEAT RECOVERY TEMPERATURE HEAT RECOVERY RECIRC PUMPS AND PRESSURE INDICATION WASTE OIL TRANSFER PUMP FRESH OIL STORAGE TANK NTS X=1,2 NTS NTS NTS I I /`MELTRIC PLUG/DISCONNECT LIT450 ® p\ LIT4507 ® © 3 r[P3] [Al] 716E®4501 [All 716L®4501 716NG 450X [3/4-C,2#10,1#10G] 7748 V.3PH U1 716P6604 ) 716MCC4401 0 480V,3PH IL1T4506 ® — I NEUTRAL GROUNDING FRESH OIL DAY TANK LEVEL WASTE OIL STORAGE TANK RESISTOR CURRENT TRANSFORMER HVAC RECIRCULATION PUMP in NTS NTS NTS X=1,2 NTS e I w I- C) O J a g 18 BUSDCUT n HEATER [P2] 716LP4401 I o 208Y/120V,3PH 0 a Ico O) N BUSDUCT HEATER `9 NTS PRELIMINARY Lo: DRN: JG al; CLEAN WATER SERVICES SHEET TITLE: SHEET: OF:xX DWG*'. ■ DURHAM AWWTF COGENERATION FACILITY �DE APR 2013 CONSTRUCTION di DSN: RSH DWG* 716-E-602 THIS BAR IS La �H2MH I LL ELECTRICAL w CAD S• ONE INCH WHEN CIeanWater Services PHASE 5D2 716-E-602 I z cHK Jp- 716-E-602_422389.dgn DRAWING IS Our commitment lsclear COGENERATION AND BROWN CABLE BLOCK DIAGRAMS PLC 10, XXXX AP�:LLC SCALE AS SHOWN FULL SCALE. GREASE RECEIVING FACILITIES 6471 LL REV 1 DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 f ENGR STAMP: • •• •• •• • • • • •• i i • • • • • • • V • • • S • • •• •• • • • • • • ••• • • •• • • • • • • • • • • • • • • • • • • • • • •• • • • • • ••• • • • • • • • • •• • • • •• • • • • • • • • • • • • • • • • MELTRIC PLUG/DISCONNECT • • • • • • • • • MELTRIC PLUG/DISCONNECT [P33] • • • ••• ••• • [P221 716SF8OOX 0 [C2] 716EF800X © .: [C2] 716MCC4401 716MCC4401 480V,3PH 7O ASH800Y - 480V.3PH r% ASH800Y ••• ••• • • •• •• [C8[ • • • [C8] • • 716SF800X-LCS • • ••• •• •• • • ® [A2] �� [P2J • • • • • 7.6Ef�00Y-LGIs [A2] J),) [P2] [C12] [C12] [C2] 71Fi1P4401 716LP4401 sr 716E®4501 208Y/120V,3PH 7161'®4501 208Y1120V,3PH PDSH800X iN TYP OF TYP OF X Y X Y 1 1 1 2 2 4 2 3 3 5 ENGINE SUPPLY FANS ENGINE EXHAUST FANS 4 6 NTS NTS I [A4] 716NIP4501 [P2] 716LCP4501 AET8501 ® 1 [C2] TET8001 [A15] 716DCP4501 ® 716LCP4501 AET8502 ® i ® [ ® TET8002 ® )>_AII [P2] 6LCP4501 716LP4401 71 208Y/120V,3PH p21 I AIT8501 [P15] 716LCP8501 716DCP4502 N ® 000 [C2] ® ENGINE ROOM AIR TEMP PLC POWER N NTS NTS v u [C21 P. AET8503 ® [A15]--.........,3 P.O [A15]< YL8501® YA8501 a AET8504 ® (00-NOLGO LIGHT) ®(HORN) [A15] 716LP4401 VL6502® YA8502 (00-NOLGO LIGHT) ®(HORN) o 208Y/120V,3PH 7 [P2]Y ui Q • a o COMBUSTIBLE GAS DETECTION AND ALARM m NTS co M N N 7I W Mt JG wT°e CLEAN WATER SERVICES SHEET TIRE: -SHEET:)0( OF�(/( DWG# PRELIMINARY ■ COGENERATION FACILITY xOT APR 2013 CONSTRUCTION OIS C` Y DURHAM AWWTF ELECTRICAL r` OsN: RSH DWG I 716-E-603 THIS BAR WHEN 'nWat; xrvices C. ■2M H I LL PHASE 5D2 DATE: 71 6-E-603 ai I <2 CHIC JKL uOFaE► ONE INCH WHEN CABLE BLOCK DIAGRAMS PLC S: )000( Z 716 E 603_422389.dgn DRAWING IS Oar commitment is elm COGENERATION AND BROWN J MPD:1.1_C SCALE: AS SHOWN FULL SCALE. eve DATE sr APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES P i 6471 ENGR STAMP: LL • • • • • • . • • • • • • • • • •. •• • • • •• • •• ••• •• • •• • • • • • • •• •• ••• • •• • • 716LP4401 • • • • • • • •• 716LP4401 208/120Y,3PH 716UH800X ��-9 � T [P2] b"b [P2[ 208Y/120V,3PH • • • • • ••• • • r • • • • • •• • 9 r[C1] • • •• • • • • • • • • • • • • • • • • [P2) '',%.,_[P21 ••• ••• ••• ••• ••• ••• SOLENOID 716DCP4501 716DCP4502 716VCP4501 716VCP4502 716VCP4501 716GEN4501 716GEN4502 716VCP4502 ® ® \ ® ® ® g• • • •••• ••••• d••• • • • • • [a] (c] [a] w • ••• • �V �� CE•2] o� (b) (Al]— [Al] [CE-2] • ••• •• • • •[C6-21 rot�o ��-2[ �o `[c] [1-C,1#6] [11C,1#6[ 716SWGR4401 [a] ro[ ro[ [a] UNIT HEATERS NTS X=1.2,3 716MCP4501 Ol [P2],NOTE 1 e ® 3 STUB UP AND CAP ALONG SOUTH WALL OF ELECTRICAL ROOM MELTRIC PLUG/DISCONNECT P161 716PP4401 716ACUB001 �( 460V,3PH [_I(ENCLOSURE POWER) r MSC] GENERATOR#1 GENERATOR#2 GENERATOR#3 716LP4401 BREAKER BREAKER BREAKER 208/120Y,3PH 716DCP4501 716DCP4502 ® ® T-STAT [CE-21,[CE-21 CIRCUIT CALLOUTS (THIS CBD ONLY) [e]�o [a(= [1-C,4,12,6#14,1#12G] 716CMM0101 716LMH0101 [b]= [1-C,7#12,1#12G] (d] �- MISC DIAN-GENERATOR INTERFACES AIR CONDITIONING UNIT NTS NTS [d]—= 716GEN4501 716GEN4502 ` ® ® CIRCUIT CALLOUTS NOTES: (THIS CBD ONLY) 1. SECONDARY CONTROL POWER SOURCE FOR 716MCP4501, [a]. [1 112'C,40#14,1#14G1 DERIVED FROM ENGINE STARTING BATTERIES. [b]= [1112-C,27#14,1#14G] [c]_ [31,50#14,5 TYPE 3,1•14G] [d]= [1-C,7#14,1#14G] N. 2[CE-2],2[CE4],[CE-6) MISC GENERATOR CONTROL INTERFACES NTS 2 • cv b. ml rri co eq N cr a a w SHEET RE: SHEET: GP: DWG/: PRELIMINARY W GRN JG o CLEAN WATER SERVICES COGENERATION FACILITY NOT FOR Mili w DSN: RSH DWG S: 716-E-604 THIS CH2MHILL DURHAM AWWTF PLCe AAPP'R�2013 CONSTRUCTION ELECTRICAL DATE: 716-E-604 CPD FIlE R. ONE INCH WHEN aeanWater SetviceS PHASE 5D2 CABLE BLOCK DIAGRAMS z CHIC JKL 716-E-604_422389.dgn DRAWING IS Our commitment is elan COGENERATION AND BROWN w A•PO LLC SCALE: AS SHOWN FULL SCALE. REV II DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES Pt 6471 ENGR STAMP: LL -- -- -- • — • — •- • • • • • • • .• •• • • • • • • ••• • • ••• • • • • • • •• •• •••• • •• • •• • • •• •• •• •• ••• •• I ELECTRICAL PANELBGARD SCHEDULE I I ELECTRICAL PANELBOARD SCHEDULE I • • • • • ••• • • • • • • • • •• • PANEL 716PP4401 LOCATION: COGENERATION FACILITY PANEL:7181P4401 • • •• • • • • • • • LOCATION: COGENERATION FACILITY VOLTAGE:480 VAC,3 PHASE,3 WIRE MOUNTING: SURFACE,NEMA 1 VOLTAGE: 208/120 VAC,4 PH•SE•1 WIRE • • • • • MOUNTING: SURFACE.NEMA 1 • BUS SIZE:225 AMPERES FED FROM: 716ATS4401 BUS SIZE:100 AMPERES• • • • • • • • • • FED FROM: 710FMR4402 MAIN SIZE: 150 AMPERES MAN TYPE: BREAKER MAIN SIZE: 100 AMPERES• • • ••• ••• • MAN TYPE: BREAKER SCCR: 30000 SCCR:10,000 BREAKER LOAD.VA LOAD,VA BREAKER BREAKER LOAD,VA LOAD,VA BREAKER CIRCUIT TIRE CKT PHASE PHASE CKT CIRCUIT TITLE CIRCUIT y1 ••• •CKT • • •• PHASE PHASE CKT CIRCUIT TITLE NO. AMP POLE A B C A B C POLE AMP NO. • • • 160.• AMP Ole •A • B C A B C POLE AMP NO. 716ACUB001 _ 1 30 3 5616 2100 3 20 2 '�ENGNE 1 BRIDGE CRANE RCPT-ELECTRICAL ROOM • • • 1• •0 • LEO• 50 1 20 2 LLH(FRESH OIL STORAGE TANK) __ — 3 - - 5616 2100 - - 4 RCPT•ELECTRICAL ROOM,DESK • •••3•• • • •380 • 509 1 20 4 SUPPLY FAN ENCLOSURE AUX POWER 5 5616 2100 - - B - RCPT-ENGNE ROOM 1 • • • 1•5• 1b • • • • 900 3000 1 30 6 716HWS8001 - SPARE 7 20 3 2103 3 20 8 (ENGINE 2 BRDGE CRANE RCPT-ENGINE ROOM 2 • lb** • 7• % • • 300 1 20 8 716UH8001,7113UH8002,716UH8003 9 - - 2100 - - 10 I- RCPT-ENGINE ROOM 3(FUTURE) 9 20 900 50 1 20 10 A174501(CH4) 11 2100 - - 12 I- SPARE 11 20 50 1 20 12 AITB501 SPARE 13 20 3 2103 3 20 14 ENGINE 3 BRIDGE CRANE(FUTURE) RCPT-WORK ROOM 13 20 540 50 1 20 14 718LCP8001 15 - - 2100 - - 16 j- RCPT-EXTERIOR 15 20 900 500 1 20• 18 FRESH OL TANK HEAT TRACE 17 2100 - - 18 716LCP4501 17 20 500 1000 1 20 18 BUSDUCT SPACE HEATER SPARE 19 20 3 1660 3 20 20 716GEN4501 BATTERY CHARGER 716LCP4501 19 30 1000 1 20 20 BUSDUCT SPACE HEATER(FUTURE) 21 - - 1660 - 22 _ 716DCP4501 21 20 200 100 1 20 22 716TCP4501,716TCP4502 23 - - 1660 - - 24 I- 716DCP4502 23 20 200 150 2 20 24 716GEN4501 SPACE HEATER LTS-SITE LIGHTNG 25 20 3 512 1660 3 20 26 716GEN4502 BATTERY CHARGER 7160CP4503(FUTURE) 25 20 150 - 26 (VN 718GEN4501-LCS) 27 - 512 • 1660 - - 2B . LTS-ELECTRICAL ROOM 27 20 546 150 2 20 28 716GEN4502 SPACE HEATER SPACE 29 1660 - - 30 - LTS•ENGINE ROOM 1 29 20 1553 150 _- - 30 (VA 718GEN4502-LCS) SPARE 31 20 3 3 20 32 718GEN4503 BATTERY CHARGER(FUTJRE) LTS-ENGINE ROOM 2 31 20 1553 1 20 32 T16GEN4503 SPACE HEATER(FUTURE) 33 - - - 36 - LTS-ENGINE ROOM 3(FUTURE) 33 20 1 20 34 (VA 718GEN4503-LCS) 35 - - - - 38 - LTS-PARTS ROOM,MEZZ.2ND FLOOR 35 2D 341 40 1 20 36 FIT4501,FIT4502 - SPARE 37 20 3 3 20 38 SPARE LTS-RESTROOM(INCLUDES 716EF8005) 37 20 130 40 1 20 38 FIT4503,F1T4504 LTS-EXTERIOR 39 20 471 1 20 40 SPARE 41 - 42 - ITS-GAS CLEANNG EQUIP AREA 41 20 340 1 20 42 SPARE - SPARE 43 20 3 5623 3 30 44 I716LP4401 GAS CLEANING AUTO DRP TRAPS _ 43 20 20 50 1 20 44 ASH8001,ASH8004 45 - - 4206 - - 46 VIA 7183E8/04402 71614P4501 45 20 100 50 1 20 46 ASH8002,ASH8003 - 47 7884 - - 48 - SPARE 47 20 50 1 20 48 ASH800S,ASH8006 TOTAL LOAD 6128 6128 5616 9620 9620 9620 SPARE 49 20 3 50 WALK IN ENCLOSURE PANEL POWER SPARE 51 20 - PHASE A LOAD(VA). 15748 SPARE 53 20 PHASE B LOAD(VA). 15748 TOTAL LOAD 5073 2906 3494 550 1300 4390 PHASE C LOAD(VA). 15236 TOTAL LOAD(VA)- 46732 •=EFCI TYPE BREAKER PHASE A LOAD(VA)• 5623 PHASE B LOAD(VA). 4206 PHASE C LOAD(VA)• 7884 TOTAL LOAD(VA). 17713 • 5- o- n 0 N 4 I w 1 I- H. 0 a 5- a 0 e7 N W F- O 9, . 0 ai co M N N 71 N lil MUG PRELIMINARY DRN: JG DATE CLEAN WATER SERVICES 7-- SHEET TITLE: COGENERATION FACILITY OF: • NOT FOR f D6N: RSH OwOS 716-E-620 DURHAM AWWTF ELECTRICAL PLOT APR 2013 CONSTRUCTION THIS BAR IS CH2MH I LL °"� 2 cHK JIa G°R'EA ONE INCH WHEN V1�1I1♦Vd�J( JC1Y1CeS PHASE 5D2 r 716-E-620 z 716-E-620 422389.dgn DRAWING IS o•re4mmi�e•Liiclear COGENERATION AND BROWN PANELBOARD SCHEDULES APPO:LLC scALe AS SHOWN FULL SCALE. REV4 DATE BY APVR Hwy. e9 GREASE RECEIVING FACILITIES `"� LL DESCRIPTION 2$SD$W Hillsboro H Hillsboro,Oregon 97123-9379 Pyr 6471 ENGR STAMP: • •• •• •• • • • • •• • - - * • • - .. - _ • • •• •• •--•--11.1- --1 • • ELECTRICAL PANELBOARD SCHEDULE I . .. ••• • • •• i a,...tei.;/ ....„ • • • • • • • • • _va‘:"...'-\ \ . ; ii •...'e' • • PiNEL:LP-10005 • • • •• LOCATION: DIGESTER COMPLEX 1 ELECTRICAL ROOM . --,..., .‘.'" 0 VOLTAGE 480/277 VAC,3 PHASE,4 W RE MOUNTNG: SURFACE % / \ %A ,,. . '5 e-. :.'"'- ---- -• BUS SIZE:60A FED FROM: MCC-10002-50 ( '''''''\\ \ •‘ 4 • f :-;-4-.,'...‘ . _At_,4,,,-.•01 EXST) „;": ',. "•••4 '•1'4• 4. •1 .....;:" • -,..,„9... r ''''' MAIN SM.60A • • • • • MAIN TYPE: CIRCUIT BREAKER ,..f,S \ \ 1,6 -4'4.91--1 4415(EX(ST) •• ' 4'... '',• .•'',4 ; ...-4 .-, L ' . : / '-•,,,, •;4;)„, • KER LOAD,VA LOAD,VA BREAKER i .. •• \:....-... SA. in-\ i , / PHASE PHASE CKT CIRCUIT 11TLE ,,,,!,..` .a.,.._•.,.■',EXST) 74`4..S.,..„._40.. .•• NO. ,A-MP POLE A B C A B C POLE AMP NO. ,16,,,Y'r • \ \ ‘. > ". --.....eii:f • \ / . Iii • 0-6.4. .85: • :••6• colic:.LiirT:.rii•: • •lik'll: CKT::EA.: • \ felt"...,,,,,, .,„ 444 (EX,ST), i'' i:/// •LIGHTSUSEMENT 1 20 1 1 20 2 NITE LIGHTS-BASEMENT \ ••••:, ‘ 0 .";•••-, ,,..."--t .. •., •'•4 ' LIGHTS-BASEMENT 3 20 1 1 20 4 LIGHTS-MEZZAHHE .• .. , , ...- \ \ . \\% /-5\ ',,‘ .."-.-• '•,..-- ,,'•:.'. - .9."1 o,14,4•1'., •')." •`",..4 47 ••• ---- ......-Ei• 7 ;--,:i ie.:_ ../.:"• LIGHTS-BASEMENT 5 20 1 1 20 6 LIGHTS-MEZZANINE \ \ , i 20 8 LIGHTS-TuNNEL \ -• ."1.-17..... ' ' .......•Ve..,„ kap H IA -. -• • , -*..... .. • •1;:e-''' FL2URciSiE4T LINTS-MAINALOOR.. e 4 h 7 20 1 4 1 20 10 UGHTS-TUNNEL MI, .% 3 \ -•',.•' '.: '" 't('''' •". 1 ''''''-•• , .... .,,,,,,''..." ...1.":":: .:-. ... / ...C',;.,;.:*--': •1.0t,Re-SiENT LipliTio-MMN RADON* • • • 20 1 WGHTS-EIEC ROOM 141 20 1 . 1 20 12 LIGHTS-STA1R a MAIN FLOOR <Ir._ 4^,1•6": •!:•' .2'. ••• -''!',•4'..4' „,••-'..,'I '..,,-'11,..;.. ''..• ‘,. .W4',,t...;' ,':`,.:'::',,,-.•••.-;,,,F,,,,-,;(0),:ot, '---,_ „.„...-• , .;:..;,*, _.,, ././ 0,,...,/ ••• •• . 20 1 1 20 14 7777 . - - A if_. i..•4,9 Pp AA RR EE : ••• .15 20 1 1 20 16 LIGHTS-GAS EQUIPMENT ROOM '''' ' l''•'''• '■''' ••''',?1,-; 1 zr•TO'4. ' ii 0.," CP'' ..-''' • 'At .".' VFD-10005 -:„.„....... '' .."-.%•`k....03'' 17 20 1 ___ 1 20 18 HPS LIGHTS-MAIN FLOOR / ii 4..e 1, 74061/6801.1 10 15. r 500 500 3 204 20 FCV8801. .-":4*, •T‘ - ,...., .....4 '... . \ ' ,..(EXST) , ...• ...'" . ,ii • ,./"*"."".."...": 21 - - 500 SOO ' ;.4, .',.Th 1 6": '1 --'- '..".4 14: 4 • '4' :•-•,. -"' ,,"'",-,'"" •,..„.,.,,,,,,I.i. , ,../ /e,re.....„....,". 500 • ,,...? •;-k' ..' .,/4..../‘‘ '''..'''' id,!•;•••"\\ ..... 411 ",..--g „,.,.‘„,-.., .... .. fp,- \ •,,..,,,,,- • .„.,,,,4,.-,v.,„ ..,__to. .... ... , : : ....,s. ea 740FV68024 25 15.• r 500 1328 r ir 26 740LcP6901-GA5 BOOSTER. ‘....,:.f•.0":. \ ',....... , / ,.. \ , - 27 - - 500 1328 44444%.r.. •, Ott. I' ;/•,•,%, ".....'''.1.‘,(.••••' Mr&i..9k2 , \%. 4 .,1'.' S. \...--"' 1/4 . ... - 29 - 500 ,..*''' ':'...+‘<"::..2 101. (ECM). TIDTAL LOAD 1000 1000 1000 1828 1828 1828 '' ' \ irk S-4.97?-1.. ,,r,---. - •= , k,.. ...,64,sr ,„%,-- ).k".1., ...- ..... I,0 . ....43,..,,.. . •-•"- ----"".."*".' ..;.; , 01-.F.Nex '- --, •••"" ..,., ‘ i'i..'..(rit,...%; ,-: 1,1 /MCC-10001 .. • ,,.._., m,,Irrif-7:. / , \.}.('•`"" :„.-• ,„.""' 14-r..:, - q;,,.. 4%., ,...-.. ...-,-.„.. ..--,,,,,,,..,,-- \ *BOLD INDICATES NEW WORK PHASE A LOAD(VA). 2828 ..---• i . _.ra .... ...... 1 ....„ . i \ l'''' 7.- ."`‘`''..0"r".1,''''..":•\ 10*.ik i (EXST) .i" ' I. ,lei OIL HE:,r ,,...r-,',..-,.,k. --.dt.•-.1,,-- , '-iil ',.,1 ,./ ‘ '`.{...., „,...," '.2.ttlf.4..',..."/"..:',A; ,iak. At.':>•Ce R.- ( Eit,...I4VIrr.cR ,--,:i.4,-- _, .,,,,,,„.. , PHASE B LOAD(VA). PHASE C LOAD A)= 2828 2828 '• ' ' ‘,S;9, ''':11,..i.,,,A41-;11' .': 1•;‘,,,,,'"r„-,411(‘I WI OW , 7'. 1, • 1 "'GAS \ ."'......"`473, P,..,---')Y \\\..,'''.).,,,?..- q.V ..."'„--',.-.-"\ ''' '' A • ..----i# N. •%..,,,, i - v- •- ,,\ N(.,,,:,• ....,ii- .' , ... ,J..- __:...-.-- -w.\I ..' #•<,. saa MOTS S .4). ,4 .\11111)##P' ..(2. . 4 , . -,) ..... 1 ,.... 4$11 4,),f X..(.1111.1,4.4/91 449••'•c:5"....'i .....,",... 754.AA rerrt4 7 f.;., •.'" Sii.loai 0.-f ,,,,, ,... 1... ,..,•i , A• '-'''I.P.A.A.:;•'••••••,".. , :A ‘ '.\A 111/7„.. ,', _ %,..-'• .r." .„...."..." ... \ ‘' ,.3..}•-A * .... ' , .,......-,,,.•, r• ''...."' ...:. , 4,4.....t..e.•• 1, ... . ‘ \eg.° ..r% ..,,,,'N, N. 00,00' p ' h , ,4,. ''4,. ;' 1 1 ....-;, 1 \ Is PANEL:PP-10006 TOTAL LOAD(VA). 8484 I ELECTRICAL PAKELBOARD SCHEDULE I LOCATION DIGESTER COMPLEX 1 ELECTRICAL ROOM VOLTAGE: 120/240V MOUNTING: SURFACE 1 ■ '•.••••-"' ••" • „,./..' ' !•! - .... • ".■•,•-•-PA-.0 \\:.; .: •2'":).24.;",`‘`••re ------ \ BUS SIZE:UNKNOWN FED FROM XFMR-10007 .4.'•.,•.".laill .... ''S' ''`V?.' '' -'•';'•""-' ,.•''''.2.,t)-'. ..-' ` ' MAIN SIZE: 125A MAIN TYPE: BREAKER rard-77'-1"; ."*-- f , .>.-C8, 's.'.■,:1/4'._i'. ' •";•eka. tt,..'.° . : ;° 40f,,_,„7:'''. ..(..-,-: _,,-• \''...- el"---.--451.... •", ."...." ..,.. 7),..„7,,,r,.......1.:: t... 4: •• . 1‘,4;/:0-0 SC CR: 14,000 -----7;t__ ii i ..,_o,„,4 I,,,>„" .IJ , <''''": k Its K vl&.42: ,....1%';:117'"-,%-•'''-7,‘ '*1.r" ...- ''''- ,,„---;),,-"" ' '7" BREAKER LOAD,VA LOAD.VA ] BREAKER ...' " I -ifiii- (fi-i: ....''„._,..4 \ -„,.,f-.. , ,T,. ,,,„ft- 1,,..i, „,.. ,..,, \ ,.." • ,-- trv`P)....-,,, ...,,..f::, , „...... • •44.• -- ,-.- •• . 461-.."....• 4•14:-..% .,-., -""--,- '..,. ,..- -4`'‘'F lui .v. •,,iii TER .., 't 712 CIRCLUT TITLE CKT PHASE PHASE CKT CIRCUT TRLE ''*41'4 ',,,-..,..70•,'-'... ‘. .-A‘ •.'" \ „-,' .,..„ \ ...". ,4,... .--L. .,..,.,,,,,, • - N3. JP POLE A B A 13 'POLE AMP NO. i 1/2.''' ' „...r„1:410.,.....„<•\ ,-. .„ ,, 1..:.,,, . ''',. ,. . 4-..,!,.', ,',, .,"'„..te *." -- _....." „.„2---, ,..;,.;,-4'. AN'r., 1080 720 1 20 2 RCPTS 6..4,. f:'L .4.V.....=. X.....,' ....:.'" "',\:.' 111' l't , ', " ..,..; -..:.e.- 720 1 20 4 RCPTS 0. : \Zap.. 8 1,'---1—-i->--' RCPTS 3 20 1 900 ..., '•;' " ..-- • 1 4\. •1,1:41)1 7 ir.-* --.,- <,-...." N';'‘,.. '\ ' •••K ..-''',:";-\.„, .., .,- , ..„--7-k. *.e ,- --,,A ,... RCPTS 5 20 1 540 160 1 20 6 EMERG.LTS,EXIT SIGNS .,5t.„i",.:„.• ,,'' •.-i...2-_-" i*,:..,,i. •••441, .1, :-.. , .„...., `x••••.1).k. „4. , it ,`1-4 ' A---'-:. ' .-1:4- -- , - .-" Ilk • 1.1 . . 150 1 20 8 ENERG.LTS,EXIT SGNS -;..,--- k,:".,,,,. ..•Y`"...-';!.:•.,-,, '',•••,._ '•••,.CA ..A.-t",,,... ,,,,....4 4,_ir< ,, c.I. -, -4,,. ..._ * 'c. ' • •4". SYSTEM \ EMERG.LTS.EXIT SIGNS 7 N 1 270 ,.. .1.1 .:t.:/,-1-- ,'„It;;",-60-.--- -4441 ..:S:•., -..\\-. ' I', • ,-"*".,21,. *,, ' , --girt■ 1.--_:•-• `1. .t ..,;:rrif;‘,,,,' -4R--,4,•• Ca:1 1 ki; EMERG.LTS,EXIT SIGNS 9 20 1 110 40 1 20 10 ENERG.LTS 0---''' 4,..??,:•;:::::,' _etfrig.r.- ."--- BOILER NO 1 CONT.PNL 11 20 1 1900 1900 1 20 12 WASTE GAS BURNER#1 CP ...i''''' I y.2--„,- r-,..•:'"'-'. :;%;"-- '' Y ., ,, .., ;? 44,'-'il:f(3.-?5,4,"4...!„,„," - 4'.''.../..-V.Wi3-.1.q.,•9,/i' . BOILER NO 2 CONT.PNL 13 20 1 1900 1900 1 20 14 WASTE GAS BURNER#2 CP • ...--' ,, ,',..',;',..%,"•c,77,,e„..-.-- ...'" ..,(:**i,. ‘. < ;'•''... •.),-..i...,' ,,,, ,,,,. 1,-se, -; .....,•,-,0-...„ ...- .a ,• ; . 1900 1 20 16 WASTE GAS BURNER ft 1 -ENGINE/GEN.CONT.PNL. 15 20 1 1900 . ' '''.°C;,:,1 4'+‘• it,,,w A '\•,,, '••• _,,,f, '• 'I'eP''':\:, .t... ,,,," '- ',..:',.....".,7 ..,'" v., , -- 1 - !rE14' 1 -:-'1. 44"-Lr Letz"=-4-i... 2.L.—..,..tg. ■ \. `.,;:'"...,%'' =?.f'.fi*' 4:', :: ,,„ '''.1 .,4"----..."fie.-');L',,,f."'N'",---"....-,-;,-Y.'"''',V.:''''• ..." ' 11 '', : ..,...Cce: SF-10004 17 20 1 830 1900 1 20 18 WASTE GAS BURNER 8 2 ----• `-t1. ."',.., -. ,. , '.•',..'" ,'f,-' '.' .. ,,'::--,, r :,-. .,4,--,..,,,tve,..,:,,;-4-,-,,, Ai„o410. ,,,,''''GE.iititAlA VA „., ', r1---- -; --- 31,:' w .),I, 1 ON UGHTS/RCPTS-ROOF 19 20 1 1536 756 1 20 20 LIGHTS/RCFTS-ROOF - Ii -,- 'I r' r.... ' ' UGHTS EXTERIOR WALL 21 20 1 324 600 1 20 22 HEAT TRACE-ROOF , I: 1 ,,:.% r':'..r'l :V... ' ...4" ' ' ..\. 4 '' LC-10020 23 20 1 100 100 1 20 24 LC-10021 -,---1- __._ 4i ' •,,,,,(TY::4.., ii;•.1.4:, ,,.."1,1,..;' .,"„.i. \',..,..,,,N.„),71%%•1 .t. •••.44,-, 4',, . . -4\•;1, -7. 44 :,. L.401.,,•••'...„,../.... ' i•-., .. , .•V, D.150-r')::1914 r ', _ ..-Yo 1,•,, .W''' LC-10022 25 20 1 100 100 1 213 26 LC-10023 ,,, , .S.,;.,-,,,,.?:,- .„`,, t. • „,.r: "A, q": \ ' dit .:.'''. .1/4, ',..,...' .,. . ,,.. ,":„..•-• ..e-. i — SPARE 27 20 1 50 1 20 28 UT-8901* ,2. ., '':3•1?'-'•••• V:frfEL6e" , ''',Z7ig"..' r• _,•"' '''..' --.;; ...i ''',:.4t.'4'4,. 1.' iii,• ;.•i',7i'."`"`•••••- ' ; SPARE 29 20 1 500 1 20 30 FCV131302* 1 I SPARE 31 20 1 1 20 32 ' '... 1; ins logiii' ''':,--'IC ' .---1-; .4. ..-. ..,,d.„:„,,-,..„-;.-v-i....,,,..,-.,...-,-.-,,kv.,_.....",,,,41%,,,..7 \, ,\.i."4,16,1',..",',,, ...,,,e'N..::, - ' - .„. ;', •. ,.., (A.-''"4''44144 a' --,,..4,1‘*.:4; ..,.. • , ..;.„._..' .,\ '...;■,...hr; •.*, --' .. ' • _.,,,,-- • .i•,--:.li SPARE 33 20 1 1 20 34 1 40.■ 4\ ,-' .'".:..1.- - '-..'",t--.:-. \.i:. --.., i i? 1 4, ‘ SPARE 35 20 1 1 20 36 - r 1 .,7„,,, ...,..t,,,, - - *--- --Irk- . .:4t, - . SPARE 37 20 1 1 20 38 A I - '" IZ , 4, ,A" ...-",,."" 'i`i, -. .).i,4 ' .$.:.-'''' ,..:,?.:;:-... ,;:', - '..S.e-, --.."."."-t--7'.-'-. , '' - ,.:('-'''';;.c... • U SPARE 39 20 1 1 20 40 1 I C.;"' ' ' • ' .::"% '9.'4. ,,,i,'..,re, 47..,r".. l',1 \ ,:1(,r' ".. '' '•''!.:rt .. ..i'Y' .' ; • i SPARE 41 20 1 1 20 42 I , ,' „,,. ,' „,',); / -..;., ,,,,.„..„,77;".o. ,„„?. ..;;,,,,,f)5,1,'"".,;-"4,:?.L.:, ,, ...i -:-.7'._ ••,;,, ill• .44:- '?.. ‘1•,...,- ''' TOTAL LOAD 4884 6606 5920 5576 [ ...-- , • • )4_.,.6r:N .r.o,';',.f..*. 4-0 VV".:„ , ... '-'=L'''''' .. 4'... :-.•.5r•''' '-; , '''.- r,i'',„. , -,„. ,-.<1.--"' ;„ 2 ,.k.r..,,,,ifyfy•-■;',4;-&-,.'0.-..":' N• '. '. ''. 10.1 .lk ' t... ..., 'Z.;-. 311 a/ ..':. * .T.IP,' "----.- • *BOLD INDICATES NEW WORK PHASE A LOAD(VA)= 10804 o. .7.. ..2 -.4,:"....',.-;:,. , k- "'lap"' .. ...1.,-,:„,-.V:f:::/,r,-'',,, Prat ‘. \ .......,.. ' ;4.'4..1 \'-,, • . .. '-'i PHASE B LOAD(VA)= 12182 '''' ''' Lr'',16-- .--:*••••:::,.??..:-.,-;,, -',...'per-,,,. ,,.7.,...c..t...),:...3...-...........„,:,1.,,,,,.... ....:;,_ .,,... , .; ..:,... -.. -. ,,,c.„. TOTAL LOAD(VA 22996 ,•: - - ) # • -• , ''",' -.. ':';',/ / - ----;;;+._.f:.1:r:.c- ,',''fr'' - \-e \ roil ' ' ------ .-, .,--•°.' -•••'•::4'.4--.., ;•f: -:. -e.',(7' ' ---- '--• '• ---- 0 '' 0. \'-' ;,.- ..„.... -..g. . ---.... -...r ' 1-411.co.,..ai ...,i- 1.2.:fr....r.:,\,..).4 ' ' e'.....-.f ti',.;:e.).:; , ...., v ,, si. .,,, ik . ....... . 2 ,.........4......—.._:.• . •.,,,..., ,.,„ i ..e..5,.,. „r"...„A \ -,. 4E40 ,.....P$1.. 100 " V-IC.,..,:- LP-10005 ELIA201 a .z,01-410/..---,,,,,g-„. ,,,," --,."›.. \'''.- I ,..i. '. 740FCV6602 . ‘,...."„.,." ', a•.?"," cf.(is 5.0. \4"- - "" 480V,3PH 120/240V,1PH .„. „ . . ...r 1. 740FCV6601 et (EXST) 740FCV6602 IS-RL---D-v-- (EXST) -., • (sc::..?„, „r.' „.;;;.-•l'..1,7. ) ,.- I ......„ . ' \--11,3] [P2] 11.2) ..,6 ...„,‘ '\.--' (i, \L TIT6601 ® CP-1001Q --• ••"' 5- ."!• ,,"*".•,'""...... ''',, SS,.----i- .-ttleAC-Hit',' toL '..; ''''. . ' 8,,.4. , --....- . ,......,„,.._.L.- ;:75: ..., ..,:;,„: „."?-',....i. ,. , .„,. `\-1A1) (EXST) •,,g, . .-'''' (14 3,-/',-.... / - .1-. ', .!- -..• • - - ..A.. :M ...--"' '•'",:fV-. '''' M ( ® ® Tz; ..."'''''' \e ,5". .._,. ,"•, C\-[A1] c-,,_[A2I --- - ,,, .., , . / -.". , /:-.•' '''...-.. V''--.^-`, 'ii". N'''''',,. '''f',..".."..'"•-41'-f•-, .(' ••• •-'" *Pr ' - ' IA21 CP-10010 CP-10010 1.1.-Ci .-,-'...'"..,,, r2fyi..4--,f_L,?.(%" ..' ., ,', ,,,.. ..:.:‘,.r=". 24:::"...-„,..---..„, '. ',..,i< .,- . ...,,. .i-• (EXST) \••••• (EXST) 1 1.- ..-• .,."'" ' i' . .. .. . ' .. ,, - :,',.....• %..t., ..11.t.'1:,.. ......"\''.1 ,,,,e'''''." '.., ..',!.,,, ‘ c,x) 1:t. ,,,,,,,,....-•,..,./. ,... .....---- -.,/,`,? ... . .,,,...- „„, • , • ,t?'.. ,,,-. .....,- - " / . ..A . .. .... ,,,,,,..., . ,..,,,,,,,,,i. '.. e , ,. (2.7„.. ...,-. ...,„ ..,. • .. • ....,.., , ,,... ; , , ,, TEMPERATURE INSTRUMENTS 480V FLOW CONTROL VALVE 120V FLOW CONTROL VALVE . .6,..., ..... ,,,,.....- -,,, -.= % • NTS NTS ' '`• •- -_ _ NTS co --.1‘." .., ....• ' --,.. 'i . ., .. ...,_ .,... oiv ... on N MAIN FLOOR PLAN CE).l.. O4 .1.1 1/4"=1'-0" a -41- 111 ORIG CLEAN WATER SERVICES SHEET TITLE: SHEET.) ( OF:xX DWG A PRELIMINARY NOT FOR ,• DM' JNH DA, DIGESTER COMPLEX 1(DC1) ■ .4- DURHAM AWWTF PLOT APR 2013 CONSTRUCTION N' OSN: RSH DWG* 740-E-140 THIS SARIS ELECTRICAL DATE: fli CleanWat;?-Services CH2MHILL PHASE 5D2 740-E-140 CAD FILE A ONE INCH WHEN GAS EQUIPMENT ROOM PLC*. XXXX CHK JKL 740-E-140_422389.dgn DRAWING IS Oar commitment 14 elm COGENERATION AND BROWN PARTIAL PLAN AND SCHEDULE cm 6471 Lu , ENGR STAMP- APR):LEC SCALE: AS SHOWN FULL SCALE. GREASE RECEIVING FACILITIES PFLJO: . REV a DATE BY AHAB OESCRIN ion 2550 SW Hillsboro Hwy. HillSboro.Oregon 97123-3379 La. .• ••• ••• • • • • •..•o••• • •• •• •• •• •• ••• • • • • • • • • • '\ MI 20MCC9910X• ____ fl_ _._.-----..--..._.___ • ••• 750FV660X• • • • • • • • • •• •• 111 )+ - I .—I • • • • • e yl ' • 750FV®X-LCS 20LC®703 .7_o WI t • • -T T 1 0 e r -_ .-'� ;J,,, \ , r HOT WATER VALVES PI \•\�/•/ I NTS X=1,2 1 f `/ O � I3FV::1 _ ' f\■\ /•/ ,\.\ c♦•7,Q \A /'/, �1s15M .__—J c`�� /� // I\i 20LCP00703 ���� /� S A SAR [1 1/2/ / �' (2 CALES ARE SPARE) (4 WIRES ARE SPAR )\i/ - 1 i 4_ II •1\ I\ Eh 715CMH0102 1 / / // - ---1.1 �� 715LCP6401 N V/ � /� ` `. s \ DC2 FOG INTERFACES ERFACES `\ \� � ", -;I ., \ ' '' i i \c NTS m Fl 1 - "A/// AIL t R , 4,7 \�\ �\ `-\� ` / \ v �' , 750FV380X i-pi 0] 20LCPC00 3 Si .I . 41 / 1 \ .„ / // 0 � / g \ 750FV380X-LCS 20EX5 101 'O s / y/ Y — -- ® I z(EXST)r `mil) _ r ...- . -�—'--- di �/� mill'.. ail- .`� � J cam_ j` . -- i i `NOTE 1 Q O Ua NOTES; NOTES; 1. UTILIZE EXISTING SUPPORTS TO MOUNT 1. UTILIZE TWO EXISTING 20 AMP BREAKERS IN PANELBOARD NEW PANEL. TO FEED NEW VALVES.UPDATE PANEL SCHEDULE. c co v oi N LOWER FLOOR PLAN O" DIGESTER FOG FEED VALVES al 1/4•=1.-0. NTS X=3,4 c DRN: RSH ate: CLEAN WATER SERVICES SHEET TOLE:DIGESTERCOMPLEX2(DCZ) SHEET: OF:xx -DWG N: PRELIMINARY L. NOT FOR MR JNH DWG PI 750-E-131 DURHAM AWWTF 'XL, APR CONSTRUCTION CH2M H ILL PHASE 5D2 ELECTRICAL 750-E-131 THIS BAR IS (�CaRW�CC $�� LOWER PROCESS PLAN PLC* XXxX 1 W CI10FIlEe. ONE INCH WHEN CHIC JKL 750-E-131_422389.dgn DRAWING IS Our commitment is clear 111 COGENERATION AND BROWN AND DIAGRAMS APPD:LEC SCALE, AS SHOWN FULL SCALE. REVN DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES. 's,, 6471 ENGRSTAMP: LL f • •• •. •• • • • • •• .. .. • • • • . _ • - - • • • • • • •• ELECTRICAL PANELBOARD SCHEDULE a-- --- — �,. .�--.-_,.� ,\ PANEL:20PP99101 LOCATION: DIGESTER COMPLEX 2 ELECTRICAL ROOM (EXST) , s - L. _ —1 ••• ••N15 BIZE.�NNKO*401•VR•• •• ••• FED FROM: SURFACE. 07FMR99102 MA 1 •ZOATS119102 • • ••MANapE�22 •• • •• MAN TYPE: BREAKER ' (EXST) DOWN- •\ • •• •• •=CR: UN�NO 'N• • • •• _ _ _ \ • • BREAKER LOAD,VA LOAD,VA ) BREAKER ;, _ CIRCUR TITLE CKT PHASE PHASE CKT CIRCUIT TITLE ZOATS99101 '' J O NO. AMP POLE A B A B POLE AMP NO. '�j� (EXST) I 4. k\ \ UPPER LEVEL UNS ITCHE. 1N 1 20 1 800 400 20 2 LOWER LEVEL UNSWITCHED LIGHTING 201P99101 .��� I <,i ••• ' - TR 00 r'KM, •Lin t . 3 20 1 200 100 20 4 PENTHOUSE UNSWITCHED LIGHTING 7 (EXST) I ® L�iHTIN COP• 'EL• • • • 5 100 2 7200 900 20 a ELECTRICAL ROOM RECEPTACLES �, • L}Y[�HTIN Cj1�TR�Q4�EL•• • • 7 - - 7200 1400 20 8 OUTDOORS AND ROOF GFCI PROTRECEPTS // I ILL Li VE`EMiANI]EMIRG•4C`•LIG•15 9 20 1000 400 20 10 LOWER LEVEL EXIT AND EMERGENCY LIGHTS �` 0. R LEVEL Gf•I PR✓D7 RfCE•TS•• 11 20 700 1100 20 12 UPPER LEVEL RECEPTACLES '(r DIGESTER 4 MUER OIL HEATER 13 20 1200 2 30 14 SPARE DG.SLU.HOIDNO TANK 2 MUCOLL HEATER 15 20 1200 - 16 SPARE __ O ° HVACLCP CONTROL POWER(20LCP99810 17 20 1200 2 30 18 SPARE 20VFD10501 �� WASTE GAS BURNER(20LCP30201) ) 19 20 800 - - 20 SPARE �� (EXST) RESTROOM HOT WATER TANK 21 . 20 1000 500 1 20 22 RESTROOM E)S FAN(20F99808) I pOVFD1050$ ` 20P20102 AR DRYER(1!5 HP)(20T99401) 23 20 500 200 1 20 24 GAS DETECTOR(204899101),CH4 ELECTRICAL (EXST) ♦ (MD COMBUST.AIR SUPPLY FAN(1/5 HP)(20f99B15) 25 20 900 500 1 20 28 DIGESTER 4 MOOR NPW LINE HEAT TRACE RQOM ♦ HOT WATER HEATER 27 40 2 3600 500 1 20 28 DIG.SLUDGE HOLD.TANK 2 MIX NPW HT TRACE HOT WATER HEATER 29 3600 1000 1 20• 30 DIG.SLUDGE SPARE 31 20 1 1000 1 20' 32 ISOFV3804' SPARE 33 20 1 1 20 34 SPARE (EXST) \ � / SPARE 35 20 1 1 20 38 SPARE ZOLCPO0703 \``�• I TOTAL LOAD 18900 16000 3700 4300 (EXST) /\ Vii%41 11 /��`� •�,•e I 'BOLD INDICATES NEW WORK PHASE A LOAD(VA). 20600 20MCC99001 /- 1 PHASE B LOAD(VA)>• 18300 (EXST) \ ♦�` ��(�� , TOTAL LOAD(VA} 38900 itik CI I / BOILER 741k./ • 20MCC99002 / , / i4k:XST) / / Ed ` c.I J t 2 41111' \ ,..„.„ ,:„ , - 4. • 4 17*.' 41*- ,,, �`. ,y r • > • /•emu I :NA o " - � L 44„.. , G,,,, _, L% . , of 44' .1 __ r ,� 4' O N re s p BOILER HEAT TIMER CONTROL PANEL(EXST) 0 1 I I\NI I.1) 0 a I rn ✓ ai co el GROUND FLOOR PLAN O" Iof 1l4"=1'-0" w oRiG PRELIMINARY °RN: JNH CLEAN WATER SERVICES SHEETTTLE: DIGESTER COMPLEX 2(DC2) SHEET: OF: °""°w �° DATE NOT FOR r- osn: RSH ow°r 750-E-140 DURHAM AWWTF ELECTRICAL WET: APR 2013 CONSTRUCTION ill THIS BAR IS /v� {=yyy _. �HZMHILL 3 CHK JKL °^°"E' ONE INCH WHEN t dP.aI1YYtlUGl SetviCes PHASE 5D2 750-E-140 750-E-140 422389.dgn DRAWING IS Our commitment isdear COGENERATION AND BROWN GROUND FLOOR PLAN PICA )000( IL :LEO MALE AS SHOWN FULL SCALE. REV. DATE NV APVR DESORPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES AND CABLE BLOCK DIAGRAMS PRJ 6471 ENGRSTAMP. IL PRJ•. . •• •• •• • • • • •• • • •• •• • • • • • • NOTE1- ••• • • •• • • • • • • • • • • • • • • • • • • • • • •• N VAULT SCHEDULE O TAG TYPE SIZE I COVER �/ 716M-13101 UTILITY VAULT 577-LA OUTSIDE DItENSI TO'H TO'L X 411'W X DUAL SQUARE HINGED LOS,SPRING ASSIST !� ,_.—.—.X_.1 • OUTSIDE DIMENSION 4161_X4'61Y X -__._- • • • • • ••• 716W-13102 UTIUT'/VAULT 577-LA DUAL SQUARE HINGED LDS,SPRING ASSIST _ : • • • • • • • • • •• • _ 6�H e a e • •• • • • • • • • g 715CMD101 UTILITY VAULT 444-LA OUTSIDE DIMENSION 4101_X4'0"W X SQUARE HINGED.SPRING ASSIST.NO.44- • • • • • • • • • 4'0"H 332P • •• •• 0 20 40 W•�, • •• • • ••• ••• ••• • w OUTSIDE DIMENSION 4'0'L X4'0'W X SQUARE HINGED,SPRING ASSIST.NO.44- / • • I° = ■= 715CMD102 UTILITY VAULT 444-LA 4'0'H 332P J 1 O 4 --�i' Scale In Feet OUTSIDE DIMENSION 4'0'L X4'0'W X SQUARE HINGED.SPRING ASSIST,NO.44- pp (0 - I 716CMFD701 UTILITY VAULT 444-LA 4'0`H 332P / � ~� 0 OUTSIDE DIMENSION 4'0"L X 4'0'W X SQUARE HINGED.SPRING ASSIST,NO.44- e � • • ••• • • •• •• w • w 715LMi0101 UTILITY VAULT 444-LA 4'0^H 332P 5,g: �'� • • rn NnrF¢ OUTSIDE DIMENSION 4161_X4'B'W X SQUARE HINGED,SPRING ASSIST,N0.55• c�3 • J 1. VAULT SCHEDULE APPLIES TO ALL ELECTRICAL SITE PLANS...)4 716LMi0101 UTILITY VAULT 506•LA 6'0"H 332P / W' • OUTSIDE DIMENSION 4'0"L X 4'0'1Y X SQUARE HINGED,SPRING ASSET,NO.d4 O ••• • U 716LM10102 UTILITY VAULT 444-LA 4'0"H 332P ` �.j H- OUTSDE DIMENSION 4'0-L X 4'0'W X SQUARE HINGED,SPRING ASSIST,NO.44- / "` •w.•a••.••.•••.•.•••• .g 716CM10102 UTILITY VAULT 444-LA d'0"H 332P / 77."-------------N\ . A , C 111 . _. — — --_.-- -- o — * I. e O * r I 3 * li / I1 i - [DB71 `� r o\{o 1– F o 1 i rw'i r s a O1 v ` *41:\ ...,,,..N...,......__ ` N { O V N cl DRN: JG oArE , CLEAN WATER SERVICES SHEET TOLE ELECTRICAL SHEET: OF DWG 10. PRELIMINARY NOT FOR ii■I Y DURHAM AWWTF ogre: APR2013 CONSTRUCTION °i 0.5N: RSH CADFI 900-E-101 THIS BAR IS Pan atCl Ce$ �j■ ■2MH I LL PHASE 5D2 900-E-101 W CAD-E-1 ONE INCH WHEN cm JKL 900 E-101_240211.dgn DRAWING IS Oar commitment it clear COGENERATION AND BROWN PLC It XxxX APPD:.LEC SCALE 1'=20' FULL SCALE. GREASE RECEIVING FACILITIES SITE PLAN AREA 101 Dws 6471 ENGR STAMP: REV M DATE BY APVR DESCRiPTIDN 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 P0.1 r .. .. • . . • •••.• • (1) • •:( • •• • 0 ------1) • : * - .-... - -.1.k L. • • _.• • • • . . • o zo 40 60 `4> „i`. — . =='/.. Scale In Feet [tt'`t� Sips: . 93._2. tf. ..... • O.._. ..•II��!/m���anu. ifs - €� , - • - .,•• * flit' &it ° alh1111110It11 2 . '" -•-• •-•-• : • 1111111111111111111111 •,: . .: N .. ■ ■■ u 111IIUIIIIUILI IIIII • 118'_5• ■■ - -_ -. ._ : ,,,4y �"— C.. • I„i,,,u,,,,Iu,,,,i",,,II„i i •. Q tr III uuIuIIIuuuuIriuuIuuuuII �A afill1e11o11M1o1111NoM �� ,' — �, ' NOTES: iill .--------_'-(-- ”" / ,''l .'?,� 1, 1. POWER SITE LIGHTS FROM 718PP4401, „�, ,,,,II,,, ,,,,,,,,,,, / - ly % ..... f SEE PANEL SCHEDULE../ 0 40 • „ff. DIM IIIIIIIIIIIIIIII 11111 %' 41! .. , ‘ , . „.. . .111r-- :--.."-jlilliilli ;f MMlILMUUlNIU i /: V /4$ MI 'MINIMUM' U I ■ / �I �j N c < S : < d f 4***/ `,, < . • • IIIMIIIIIIIIIMIIMIMIll i , -*all III . . Ap....4.. ,,,,,,_40,0„, • ., ‘ ... ,4- 4 1 ,‹. 4&1/14.10,...., 1 OM 111 � / j o � • << •F .�t�� \ . • .ri \.i/ j,it \ � <c• L f• s��������a���� unsimmi , ,,. �/\: ifs* ♦. • t '.4 4.4011,,,„ ,..• e., , . : '; . ,, , ,i, 11111111M11111111111111011 1 . , P1' . Immunlimommun vi-----: : fill ,1111r1:77\:, 14 .v • / k4-14A v :::1:ih:•r!;::!!': ... �,, A I �� : Tul 't. , 4P*, .. i pm muumuu- 1 in num i ; wc,2„," GI ----...74 ..-4:. • 44,.. - ,. c \ - \ --- ............... ._. c MATCHLINE,SEE DWG 900-E-103< v N I N O o RD N: JG � : CLEAN WATER SERVICES SHEET TITLE: SHEET:xx OF:xx DWG PRELIMINARY a° ELECTRICAL NOT FOR Dsrr. RSH Dwor. 900-E-102 THIS BAR IS 'PLOT APR 2013 CONSTRUCTION ONE INCH WHEN Pall♦YdlfGi Services PHASE 5D2 F GAOFl�� CH2MHILL °"`� Q CHK JKL 900-E-102_240211.dgn PLC* XXXX 900-E-102 I z DRAWING IS 0•re•mmi�e•tiselar COGENERATION AND BROWN APPO:LLC SCALE: V=20' FULL SCALE. SITE PLAN AREA 102 LL REV. DATE a APVR DESCRiPTaN 2550 SW Hillsboro Hwy. Hillsboro,Oregon 977239379 GREASE RECEIVING FACILITIES : 6471 ENGR STAMP: • • • r •• ••• ••• ••• •• • • • • • MATCHLINE,SEE DWG 900-E-102 ••• •• •• ••• _ • • • • - - - - \. r — - - • • •• { N L ' II III 11111111111 44, `\ ; • .\ -2 16201 P !�' , • _-.. •• •••• •• . o• \ 0 20 40 60 • 111111111MINIIIIIIMMIIIIIII II %. _ _4.=�C��LI -• l_ } f f 4� ��\ • • • • Scab lG Feet `. `\ I1•c.2#12.1#1251. '- •• ••: i•• 111118 MI [—. .TT . •ri-- y \OFSITELIGHTING • �• • • IIIIIIIII III 1 II % \` 1 i III I II 0 II IIII II III I • ,,'•P2♦ :i:: NOTES; ■III ._ III 111111111 111111 II III �;• \\ \ 1. POWER SITE LIGHTS FROM 716PP4401, At \ SEE PANEL SCHEDULE.HIMMMUMMI1111111 -.I,II,II„�, IIIIIIIIIIIIIIIIIIIIIIIIIIII • y■ 1 "• l I @.,,, 1 0 0 LOBE OIL E3 a 4 STORAGE • 4 tlIl 0 P2 . a 110 . a • • I • I • • • q - . [OB11]-_' 'IIII ! rob 1 mi lir_[DB6o1 Ill i, m II .__...__n I �,.::;1A [DB131 ,i1;1�! �( RE) �, - 716LMH010 a �� CLEANING • �i`...11,ii1r, ts0011.11_I 1 0 ro.GO 'si "EQUIPMENT ! :I COGENERATION lDB° , 716CMH01 o2 j ``�\`�� i[DB1z BUILDING ; [DBS] �� v 7\�.. • [DB15 ❑ � r:I I. • ��—� ID81 i L4B1a1 i� `,/`, • M a. I�._.... _ ——•f 7, GAS •, , [DB16] CLEANING I' 716MMH0101 [D820] -- EQUIPMENT • . �I a 44 —c,i r - Ill ° 716CMH0101 ` I= M * - m I 1 s q ENLARGED PLAN N I I 1•-10 1 1 I-- _ — Q — I- O '.`f �5 Y a c > - Ii _ - - - - -y— — _— - - — — � __ . a _- ,' ,w. — - --- - .. MATCHLINE SEE DWG 900-E-104 CLEAN WATER SERVICES SHEET RILE: SHEET:XX OF:x( DWG S: PRELIMINARY . oRN: JG DATE; ELECTRICAL O 111 NOT FOR DURHAM AWWTF glen APR 2013 CONSTRUCTION cn OSN: RSH DWG" 900-E-103 THIS BAR IS (leanWater Services CH2M H I LL PHASE 5D2 900-E-103 w .0. ONE INCH WHEN PLCr XX(X Q CHK JILL 900-E-103 240211.dgn DRAWING IS Oar commitment is elect COGENERATION AND BROWN Z SITE PLAN AREA 103 Dws L �Po:LLC E 1•=20' FULL SCALE. DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES Pwx 6471 ENGR STAMP. LL REVS DATE BY APVR . •• •. •. • • . • •• . • • • • • ••• • • •. - _ MATCHLINEE S`DWG 900-E-103 • • •• ••• • • N. 7 •• - ---- !rr' Asa,. ... ..._. • • ..r•,..,.,...„,........ ... '� • J o �,m•._ .. .....DG 3+50 _ ...... ..DG •4+00. ........ ..._ Ems:'••• ••! _...•...•6/ �G ...•• •`. 0 20 40 60 �I A_ � S ■ (7 ........_.. ° i Scale In Feet I —� S - S • VI .$ Wr ... ._...._ _ CO J I R 0]16] •//U /, 1 715GMH010� NOTES: /- [D85] I a'!+i� .___– �,.. _'—„''� 1� 16201 TYP �w * 1. POWER SITE LIGHTS FROM 715PP4401, �� �� [DB21 �,' I '61� ,�: -9 ;,A SEE PANEL SCHEDULE. I • 1 [D341 �[DB2] =P .e0 m I 716MMH0102 0 • 1 \ BROWN GREASE RECEIVING [1'C,2#12,1#12G], FACILITY �,, TYP OF SITE LIGHTING r -- I -''' n. , ..., \ I S - v/F 159s7 �� '-i■ Iii 1 I Wr I I I I - DIGESTER COMPLEX I �- IQI IDn (DB2]I - ( , Sry DG 1+00 m I I { O 1 . ,,� [D81] 715CMH0102 / } . [DB4] / I I /] I NI I I a co c, M W O 1. 8 NU 10001P 'Ale ..1: 1. / I -alll -.col 41111 iii ,r f/i'I I � ��+tea I^ - � / \ AFFs'- .\. '' OI,410 1r' 41 --""milsw------ese /77 I at cr gdi OR1G 00 DR JG CLEAN WATER SERVICES 5"E�„"LE' �: OF. �.: PRELIMINARY ELECTRICAL NOT FOR cn DURHAM AWWTF APR 2013 CONSTRUCTION RSH owcr 900-E-104 THIS BAR IS M �. _ CH2NIHILL w cAOFi�r. ONE INCH WHEN �f,�I1W�I JGl V1CCS PHASE 5D2 - g0Q-IL-1 04 DATE I w act JKL 900-E-104240211.dgn Pecs XXXX DRAWING IS Our COGENERATION AND BROWN LLC SCALE r=20 FULL SCALE. �� APVn WP11ON 2S5OSWH®sbaroHwy. FfNaboro,Oregon 971239379 GREASE RECEIVING FACILITIES, SITE PLAN AREA 104 6471 NGaST,u,P: LT- REV 0 M • • • •• • • • • • • •• •• • • • • • • • • •• • • • • •�• • • • • • • • • • • • •• • • • ••• 1• • • • • • • • • •• • + • •• • • • • • • • • • • • • • • • • • • • 100SWGRO102A I I (EXST) I NEW SECTION AVAILABLE FAULT 1 I I f WITH FUSED SWITCH CURRENT AT THIS BUS I ••• • • • • •• ••• IS 7.33 kA SYMMETRICAL 1 I • • 1 400E1 • ••• ••• •S • • _ I •• • • • - 1 1 ry 716XFMR4401A I1� 'UNIT SUBSTATION'A" I A 480V-13.2Y/7.97KV - 13000KVA(ONAN)(FUTURE 3750 ONAF) 4000A BUSDUCT / Z=5.75%(EST.) I 716SWGR4401 II` Y 1 GENERATOR 1 SWITCHGEAR III I 1 480-120V TO/FROM MASTER I m GENERATOR MULTIFUNCTION CB TRIP, CONTROL PANEL ,W'p FEEDER RELAY CLOSE, 716LCP450I ,: NOTFS• T CB TRIP, r`r®1rcFere STATUS W CLOSE,I 4000AT I STATUS 1 T�T T 1 co 1. IRIG-B TIME BASE SIGNAL FROM SATELLITE CLOCK IN 716LCP4503. L,S,I,G e®®e® j 2. EQUIPMENT PROVIDED BY WESTERN ENERGY SYSTEMS/GE. I 4000AF 0 3.PROVIDE KEY INTERLOCKS FOR MAIN AND TIE BREAKERS WITH i NOTE 1 PROVISIONS FOR ADDITION OF SECOND TIE BREAKER IN THE FUTURE. \ � NOTE 3 2 INTERLOCKING SCHEME SHALL ALLOW ONLY TWO BREAKERS TO BE I \ CLOSED AT ONE TIME.—I© 4. PROVIDE DELTA CONNECTED SPD'S FOR ALL 480V SWITCHGEAR,MCC, TO/FROM (3)4000:5A CB TRIP,CLOSE,STATUS MASTER GENERATOR I AND PANELBOARDS WHERE SPD'S ARE REQUIRED. CONTROL PANEL ® + 716LCP4501 1 BUS A:600V,4000A,3PH,3W,100KA SCCR (3)4000:5A TS{-.- I I BUS 0 KA SCCR 3-PH, X BU B: SCCR 1 • • • «— —� L,S,I,G (3)1600:5A E TS 3000AT 3200AF MULTIFUNCTION CB TRIP, GENERATOR RELAY CLOSE, CB TRiP, or T r STATUS L,S,I,G L,S,I,G L,S,I,G CLOSE, `®1®lee NOTE 1 TO/FROM MASTER , I 1800AT 500AT \ 1500AT >_41D, STATUS / T�T T �+ ' GENERATOR 1800AF f 800AF / Y 1600AF ee®®® ENGINE CONTROL PANEL Y SPD I 480.120�' Y1 ' �.v:�:�:' TRIP 716LCP4501 480-120^^ Yi NOTE 4 TO TO MASTER NOTE - GENERATOR , I CONTROL PANEL • CONTROL PANEL I • • 716LCP4501 716LCP4501 I a I a) N ~ esi TO STATION TO BROWN GREASE CO SERVICE MOTOR RECEIVING FACILITY r P CONTROL CENTER MOTOR CONTROL I Y' r 716MCC4401 CENTER 715MCC4401 1 O I (3)JC a. I 480-120V I h NOTE 2� G1 I I $ I I m n (3)1600:5A F TS.r X aU 0 I- O 1 (1)200,5A I a I TS� 716NGR4501,NOTE 2 C200A 10 SEC 1 GENERATOR SWITCHGEAR ONE-LINE DIAGRAM cn NTS (n 716GEN4501 N GENERATOR I �I 850KW,480V,0.8PF _ PRELIMINARY CLEAN WATER SERVICES SHEET TITLE: SHEET: OF:xx DWG it: NOT FOR 0• DRN: GJL ppTE. Y DURHAMAWWTF COGEN BUILDING PLOT APR 2013 CONSTRUCTION °' DsH: JL DWG#: 900-E-601 THIS BAR IS �■ ■ZM H I LL ELECTRICAL DATE: w C1eanWater Services PHASE 5D2 PLOW xxxx 900-E-601 < CHIC XXX CADFILE#: ONE INCH WHEN OVERALL z 900-E-601_422389.dgn DRAWING IS Our commitmenti■clear COGENERATION AND BROWN APPOLLC SCALE: AS SHOWN FULL SCALE. DESCRIPTIDN 2550 SWHIIlsboroHwy. Hills6Dro,Oregon971239379 GREASE RECEIVING FACILITIES ONE-LINE DIAGRAM CWS 6471 EHCasTAMP: LL REV# DATE BY APVR • •• •• •• • • • _• :•• • • • • • • • •• •• • • • • • • ••• • • •• • • • • • • • • • • • • • • • • • • • • • •• I FUTURE SECTION WITH ••• ••• ••• ••• .1. •••FUSED SWITCH • • •• • • • • • •• • • • • • • • • 100SWGR0102B (EXST) I 1 t 1 � I ••• ••• • • •• •• NOTE 5 I �I---AVAILABLE FAULT • • I I CURRENT AT THIS BUS • Fl 400E I I IS 7.33 kA SYMMETRICAL • • ••• ••• •• • • I ----L • ••• • • -1 I. -} 1716XFMR4401B(FUTURE) IF.x-.-. UNIT SUBSTATION'B' I p ' ' I • • 480V-13.2Y/7.97KV --- -13000KVA(ONAN)(FUTURE 3750 ONAF) .1 r. Z=5.75%(EST.) J l I . Y Yz 716SWGR4401 I GENERATOR ♦� SWITCHGEAR 4 I 4000A BUSDUCT(FUTURE) (3) W I 480-120V TO/FROM MASTER � l, MULTIFUNCTION CB TRIP, GENERATOR n ^ FEEDER RELAY CLOSE, CONTROL PANEL I ui CB TRIP. �T®r®70Te STATUS 716LCP4501 I CLOSE, Z L4 AI STATUS 0+0+0+0+ I of 0 4000/AF 1 ® '81 ♦ y NOTE 2 2 I / OU I— J/ I I (3)4000:5A Te/--- I BUS B:600V,4000A,3-PH,3W,100KA SCCR BUS C:600V,4000A,3-PH,3W,100KA SCCR 7( • < v • • I (3)1600:5A E T 3200AF DUMMY ELEMENT (NOTE 1) 1 MULTIFUNCTION CB TRIP, ^ GENERATOR RELAY CLOSE, ^ CB TRIP R$O4O+'li!4'iP.rr r r � STATUS ^ CLOSE, TO/FROM MASTER 0 L,5,I,G STATUS e®®® ENGINE CONTROL Y SPACE L,S,I,G L,S,I,G pal I NOTE 3 NOTE 2 1500AT E CONTROL PANEL PROVISIONED 500AT aDDAT \ 1600AF ` ♦ ♦,♦, ♦, TRIP ) I 0∎®∎®M®L® 480-120 Ys (NOTE 1) SPD 80 11 I i = I TO MASTER NOTE I GENERATOR f I CONTROL PANEL a 716LCP4501 an N � NnTFC. TO BROWN GREASE TO STATION I w I- I 1. PROVIDE SPACE FOR FUTURE CTS,PTS,MULTIFUNCTION RELAYS, YYs I RECEIVING FACILITY SERVICE MOTOR BREAKERS,ELECTRIC OPERATORS,ETC AS WOULD BE REQUIRED FOR I )G3; MOTOR CONTROL CONTROL CENTER A COMPLETE AND FUNCTIONAL SYSTEM,SIMILAR TO WHAT IS SHOWN 9 I- I • ® I ,G3 CENTER 715MCC4401 716MCC4401 1 FOR LIKE EQUIPMENT. a I 480-120V I 2. IRIG-B TIME BASE SIGNAL FROM SATELLITE CLOCK IN 716LCP4503. 0 3. EQUIPMENT PROVIDED BY WESTERN ENERGY SYSTEMS/GE. Iry $ I 4. PROVIDE DELTA CONNECTED SPD'S FOR ALL 480V SWITCHGEAR,MCC, m NOTE 3 I AND PANELBOARDS WHERE SPD'S ARE REQUIRED. �( 5. INDICATED EQUIPMENT SHALL NOT BE INSTALLED IN THIS CONTRACT. W I PROVIDE ALL NECESSARY PROVISIONS TO ALLOW FOR FUTURE Q -___ - EQUIPMENT AND CONNECTIONS SHOWN. UNDERGROUND CONDUITS 7y-� i SHALL BE INSTALLED IN THIS CONTRACT.SEE SITE PLANS AND a I (1)200:5A l I DUCTBANK SECTIONS. T5� I 1111 480V FUTURE c D 200A l''''-715NGR4502,NOTE 3 GENERATOR 3 CR L 10 SEC I 716GEN4503 GENERATOR SWITCHGEAR ONE-LINE DIAGRAM M 716GEN4502 NTS N GENERATOR 2 •I 850KW,480V,0.8PF IN I P9 CLEAN WATER SERVICES SHEET TITLE: SHEET:( DF:)Q( DWG N: PRELIMINARY S ORN: GJL DATE: COGEN BUILDING NOT FOR CH2MHILL DURHAM DA°�E APR 2013 CONSTRUCTION S' osN: JL OwOr, 900-E-602 THIS BAR IS ELECTRICAL W 3 CAD FILE t ONE INCH WHEN QeanWaber Services PHASE 5D2 900-E-602 01K XXX 900-E-602422389.dgn DRAWING IS - Our eomm1I e.t it clnr OVERALL FtCt�X COGENERATION AND BROWN - APB LLC SCALE AS SHOWN LL FULL SCALE. REVA DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES ONE-LINE DIAGRAM cws 6471 ENGR STAMP: _ ■_ M -'' - • • • •• • • • • • • • • • • • • • • • • •• •• • • • • • • TO TO • ••• • • •• • • • • • 716SWGR4401 7165WGR4401 • • • • • • • • • • • •• •• •• •• • • • • • ••• J: t • _• • • • •• • .- 1- 716MCC4401 • • ••• • • • � r T —'— • • 716MCC4401 68 L.S.I.G. LS.I.G. 1 1 8B • • • •• ••• ••• ••• ••• --CEO i 716DPM44011 ` K BOOAT 116DPM7402 DPM I 800AF "N.C. N.C. BOOAF DPM 6M 8M / NOTE 5 1 D 1F i 103D,480V.3W3F ND,65 KAIC048.5KA AV 2IA ABLE 3PH 2EMMETRICA3M 4M 5M 5C L.S.I. N.O. 4 90 __••yM••• ••� •••1.:D,•480II,%+F ND,48.5 o1C,65KA AVAILABLE 3PH SYMMETRICAL METRIC 11M NOTE 5 13M A- 1 1 1 1 1 1 t 1 t t 1 1 t t 800AT • s• '• I. • �'0 1I BOOAF J`/ ) • l• • ) • • ) • • ) I CONTINUED 50 15/M 15/M 15/M 7/M 7RYi 50 200 35 35 3IM 200 70 NOTE 1 7M NOTE 1 J 70 h00 •• 51! • /M • IeM 15 7!M 50 35 35 ?BELOW LEFT 11 11 11 11 NOTE4 11 11 11 11 NOTE 4 NOTE 2 NOTE 2 I VFD I I VFD I VFD I VFD I I VFD I AMPS SPD SPD AMPS I VFD l I VFD I VFD I VFD I I VFD I NOTE 3 I- -f ® ® 6 / 11C41 0 O ® 0 0 0 la 150 TS4401 ® ® 4 4 • 0 t5 29.8 FLA NOTE 4 O O FLA NOTE 4 Z o wWo > > z N o- > . N tea 0 O Oz M va� e 0 F s � . 0 s 2 5 � S � o oN U- N LL o $a' ce d a5 $ J J� i,H NULL c-U W _ N0 8g §o IW U N W Y 1.2 .2 m _W p WU S W U p K U d a d a IX CI- xN S wU. V'1- W Y J ] J LL W ffi FiLl D: I-0C raU d 1-,10.K d ey d zW N�5 S mw� aw7 d° wd W d`°< ` z > zx U U JJawe 3wg O7 6w2 '° 2 zx z. O 716PP4401 ZiS J s.n�KFOD r`xo'7 j wrn y ww nd au LL J � � Ill ww NOTE 2 716XFMR4402 480-208Y/120V 3PH,4W 30KVA 716LP4401 L 716MCC4401 1000A,480V,3W+GND,65 KAIC,65KA AVAILABLE 3PH SYMMETRICAL 14F 13D 13F 15C 15E 15M 14M 16M -+ t--- 1 f 1 • . • CONTINUED • a ABOVE 50�� 15/M.�' 15 � 7/M 7/M 50 , 35.E 35��; RIGHT 0 N Al 1 1 w -- -- , `-- --- '• -- --, •-"-• ---- i J J J I i- O~ :VFD: ..a' :VFD: �: .-i :VFD: ;VFD: ;VFD J a g r J` 1, I, I, I 1, NOTE N DI 1. SIZE BREAKER PER MANUFACTURER'S REQUIREMENTS. A A p/� I 2. PROVIDE DELTA CONNECTED SPD'S FOR 480V MCC AND PANELBOARDS. 716MCC4401 ONE-LINE DIAGRAM ^,25`; n 7.5�p� ±,5-V� -3.-' ri, 1-�:� ,•-...'s 20 ,•(,,'15 '; �,15,V O 3. PROVIDE MELTRIC PLUG-IN STYLE DISCONNECT,TYP UON. NTS - - - --, - 29.8 FLA - ' -- a 4. MOTOR IS 900 RPM,DRAWING 29.8 FULL LOAD AMPS SIZE VFD AND 0 Wa' 0 W p M f N 2 fz BREAKER ACCORDINGLY. H 1-1- >,_p f 8"' O a O Q c' d5R d5R o57 JKIS oKlr N&H^ .0 O- 5. MAKE PROVISIONS FOR FUTURE BUS EXTENSION. Z OO g 'W U,:� 8 w U n 2 it U c� ,°r,= r+ °m w>it g w r w i CO LL Q E d W 7 A 01110 J a a W U d x D O z o 2 L°0 z 2 W Z rn ¢q2 a D=a e�0'a m xa ‘,,i20- LLz O LLz O LLz M ,_CU2 mOv2 <L1f ,Lwgd2 (0c�a� � x� WO '=D'a Ka I..x D_'a E.LLF-a c-Ill rn'L WWLL nW LL N N a COI PRELIMINARY w DM: JNH OR'G CLEAN WATER SERVICES SHEET TITLE! SHEET. OF: DWG N: o ___ DATE: ELECTRICAL NOT FOR Y DURHAM AWWTF P<DT APR 2013 CONSTRUCTION °' DSH: RSH DWG R. 900-E-603 THIS 8AR 15 C ■2M H I LL PHASE 5D2 DAB 900-E-603 ui g cHK JKL CAD FILER ONE INCH WHEN Z 900-E-603 422369.dgn DRAWING IS Oar commitment ieru st COGENERATION AND BROWN 716MCC4401 FLCR XXXX I SPD:LLC SCALE AS SHOWN FULL SCALE. GREASE RECEIVING FACILITIES ONE-LINE DIAGRAM cws LL REV N DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 971239379 6471 ENGR STAMP: PRJR • .. • • • • • • •. .--41—.--6—a."1"--1-1-9 . . •• • • • •.. •• • •• • • • • • • • •• •••• • •• • •• • •• •• •• • • • • • ••• • • ••• • • • • •• • • • ••• • • • • • • • • • • •••• • •• • • •• • • • • •• • • • • • •••• ••• •• ••• ••• • • •. •• • • • •• • • • eoch S.• •• • • • • • TO TO • ••• • 716S W GR4401 71 65 W G R4401 1M1 L.S.I.G. •� 715MCC4401� 715DPM4401 3B �--� I5B 715DPM4402 DPM i K F N SOOAF I DPM 3M N.C. YY N.C. 5M I 500AF 1 600A,480V,3W+GND,65 KAIC,21.8KA AVAILABLE 3PH SYMMETRICAL NOTE 4 600A,480V,3W+GND,65 KAIC,21.8KA AVAILABLE 3PH SYMMETRICAL 1 NOTE 4 2K 2H 1M 1G 2F 2M 3E L.S.I.",N.G. 5E 6M 6K 6H 6F 8M Q/ 80 6D 7M r_9C 9E 9G 9M 500AT 1 1 1 1 i 1 1 1 t i --- ----r---� 500AF ) ) ) Is Is/ 1/ !/ 30/M 30/M 20 30 3/M 100 4M 100 70 30/M 30/M 20 30 3/M 15 15/M 3/M 30/M 30/M 20 12 12 1, NOTE, NOTE 12 12 1, 1, 11 12 1 _ , I I VFD I I VFD I SPD SPD I VFD I I VFD I I VFD I I'17:j-L11 VFD 1 f NOTE 2 NOTE 2 _ I I I 1 f I I I I. I. 4111 0 ® 715ATS4401 55A ® ® 5 0 0 ® 0 \ 5 y \15 \15 y \5 1j w.Z 150 A / _O Ui p Lu F¢~ S N h/- cs TU r�� _� Q0 o pir pQW °�&h No,„ W M O PYif-Oct N41 yy~� NAU J p8'2 00 nR 11�- _ FK.-. �p(/���.-.I V N XI ' �a ZKr ��iUr Q �QN OOOKN a UN IN U � Ul+f Q[7W LLw OQ7W -aZ 3W 3p oaa =tea 3 + x3rc $3 e O v yK aK Q X_ w UO2 cOU2 715PP4401 ` a. a aZ a w� w a OK SOW WOO OWO �n(O� b °- oWW° uy UO. (O7U� �� �OZ �c7U2 x[O�i�K7 O NUwO ALLH- -Lh nLLli nV1JC LLS'0. I LL Al f I�OLLLL I�'W OJ4 nP i Ai 'OLL I�OLLR6 I�LLrC.LL. BOLL !`LLOW� NOTE 2—r • 715XFMR4401 I /480-208Y/120V a 3PH,4W L9'- 30KVA 0 iv 715PP4402 715LP4401 I w tO o NOTE. NOTE 2— J D_ 1. SIZE BREAKER PER MANUFACTURER'S REQUIREMENTS. 2. PROVIDE DELTA CONNECTED SPD'S FOR 480V MCC AND I 65 PANELBOARDS. 3. g PROVIDE MELTRIC PLUG-IN STYLE DISCONNECT,TYPICAL 0 UNLESS OTHERWISE NOTED. N w 4. MAKE PROVISIONS FOR FUTURE BUS EXTENSION. t- I 0 a co o, 715MCC4401 ONE-LINE DIAGRAM N NTS vt g w Dart N: JNH CLEAN WATER SERVICES SHEET nnE: sHEET:)0( OF:XX DWG M: PRELIMINARY °'. DER RSH DWGE 900-E-604 THIS M `=yy�� DURHAM AWWTF ELECTRICAL APR 2013 CONSTRUCTION OTRUOCTION Q CHIC JKL CAD FILE N: ONE INCH WHEN CleanT'T' 1 STVices CH2MHILL PHASE 5D2 DATE: 900-E-604 Z 900-E-604 422389.dgn DRAWING IS 0•r eommitme•t is clear 715MCC4401 PLC» )(XXX J SPD:LLC SCALE AS SHOWN FULL SCALE. COGENERATION AND BROWN LL REVN DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES ONE-LINE DIAGRAM CWS 6471 ENGRSTAMP: • • S. •• • • • • • • .•• •• • •• • • • • • • • • • • • • • • 1 • • • • • • •• I I i 1 • • • • • ••• 1 8001600/3) I 1 800/600/3) i 120MCC98101 __ ._ • • • • • • • • •• • • • ••• • • • • • • • a� • • • • • • • • • `• I I i • • • • • • • • • • I • • • ••• ••• • 800A CU S.480V.3PH,3W,65KAIC Mill Mil ' 1 1 1 i- 1 1i' 1 1 1 1 1 1 1 i i i i_ I• r 600 1 fi W•I MCP ) MCP ) MCP ) 2013) MCP ) 20) 10013 MCP ) MCP ) 20) 15/3) MCP ) 15/3) MCP ) 15/3) MCP ) ••• •A) •••'4. )• •••'•) • I 1 Z 6Ul2) 10012) I 10012 60/2) MCP ) 7 vF0 • •� ••• •j•• •• 110 l z 1 1 " pU I 1 I I A --- - _ 2UATS99102 ' O� II il I ■ • ■ r%;•r ■ HH �� _ 20ATS99101 L __I I MN o CO o n &o o ® o © 3HP 0 ;-_I 0 0 0 0 e © 0 I'iXFMR991O1 y L 20XFMR99101 � CC __"11 a w O g r- g o 480-240/120V 480-2401120V 0 x x w I~- w U O o -n - o z O Z ® o: p 37.51NA 37.5KVA n 0 U ?n t r-wja a. �_ fu m z� s �s a oo N g e �� �w N °� CC �~ > Ce OU� az ¢ mq n Co 0Oz ,�„� a- wn o, o ¢n w ��+� ¢ uua U .JO g Fa nXw I CC lY� L g act > o < `YO > ¢ �H. � on a L} w o m 0 m� a, n. p o Fna -I ha , , owl a. m� o o �G' �� o t?� o' °oo ow ~ mod Wx ' zj g a C• J oo c�7 � � Q 3311 3�J Nn LL On hN SJ ICC LL Z Nam WC) Q C)O: fn o OUf9 J J IroZ ~W ZZ w wa LQa- 1:1lx I20MCC99102 .--- - yu 800A CU BUS,480V.3PH,3W,65KAIC 9M 11K I O I p� 1 1 1 1 1 1 1 1 -1 �-r i 1 1 i 1 -- ' zI MCP) MCP ) 20/3) MCP ) 100:3) 20) MCP ) MCP ) MCP ) 15/3) MCP ) MCP ) 15/3) 15/3) 2013) 20) Z_ 02 ►1 AL WC, I 'V �1 ►1 11 ►� I I 1 - - -- - -- - - - -- - I— J III a m ® E. m ® ®■ ®■ M. El r • • • • ••• • • •• •• • • • • • • ••• • • •• • • • • • • • • • • • • • • • • • • • • • •• • • • • • ••• • • • • • • • • • •• •• • • •• • • • • • • • • • S • • • • • • • • • • • • • ••• ••• • 1 2 3 4 5 6 7 8 • 9 • •••0 ••• • 11 • •• 1C 2B 3BL&3BR 4C 58 8G 7B 8C 9BL j 9BR • 10• • • •11••• • I (SPD) (POWER I (POWER (SPD) • ••• • • • • • •• METER) METER) 2D 3018 3DR 5M 7M 9DL S 9DR 10D (MAIN (MAIN 1F 4E BREAKER) BREAKER) BE 11F 2F 3FL&3FR 9FL&9FR 10F 4M 8M 1H 211 3HL&3*R 9HL&9HR 10J 11H ---' -.-- - 8J (SPARE) 1K 2K 3KL&3KR (BLANK) 9K 11K NOTE 1 — 10M - NOTE 2 1M 2M 3ML S 3MR (BLANK) 9M (SPARE) 11M (BLANK) 20MCC99101/20MCC99102 ELEVATION 1.PROVIDE NEW BREAKER TO FEED 750FV8901. I3/4"-1'-O 2 PROVIDE NEW BREAKER TO FEED 750FV6602. I I20MCC99101 20MCC99102 1C 20F99804-Digester Control Buiding AHU 3FR 20ATS99101 Feed 7B Main-2 Metering 9K 120P10202-Sludge Recirculation Pump 2 1F 20F99803-Electrical Room AHU 31-IL 20M10101-Digester Feed Sludge Grinder 1 7M Main Breaker No.2 9M iFV3802 I1H SPARE BREAKER 31-R Welding Receptacles IC Main-2TVSS tOB 20P20102-Primary He Loop Pump 2 4 1K 750P0202-IPS Hot Water System Pump 2 3KL Sump Pump Control Panel Feed 8E 20P10402-Digester Sludge Holding Tank 2 hiker 011 Pump 10D 120P20202-Boiler 2 Recirculation Pump 2 ■o iv 1M FV3801 3KR SPARE BREAKER IM 20M10402-Digested Sludge Holding Tank 2 Moor 1OF I20P20302-Hot Water HEX Recirculation Pump 2 I di i- 2B 20P20101-Hot Water Primary Loop Pump 1 3ML 20M99704-Digester Complex 2 Road Gate Operator 9BL 20P10502-Digested Sludge Pump 2 10.1 �SPARE BREAKER 1- 2D 20P20201-Boiler 1 Recirculation Pump 1 3MR SPARE BREAKER 9BR 20ATS99102 Feed 10M !SPARE BREAKER a 2F 20P20301-Hot Water HEX 1 Recirculation Pump 1 4C Main-1 TVSS 901. 20M22102-Hot Water Boiler 2 11C I2(F99802-Digester Contrd Building Exhaust Fan 2 I 2H 750P0201-IPS Hot Water System Pump l 4E 20P10401-Digester 4 Mixer 011Pump 9DR 20ATS99101 Feed 11F 20F99805-Digester Contrd Building Exhaust Fan 1 2K 750FV6601 4M 20M10401-Digester 4 Mixer 9FL 20M99703-Control Building Hoist 11H 120P20401-Building Heating Recirculation Pump N 1 Ca 2M 20P10201-Sludge Recinilation Pump 1 5B Main-1 Metering 9FR 20M99702-Control Building North Rol Up Door 11K 1750F\E602 I I 0 0 3BL 20P10501-Digested Sludge Pump 1 5M Main Breaker No.1 911L 20M10102-Digester Feed Sludge Grinder 11M '.BLANK a 3BR 20ATS99102 Feed 6G Tle Breaker 9HR 20LCP99401-Air Compressor I 3DL 206,22101-Hot Water Boiler 1 6.1 BLANK I c OD 3DR 20ATS99101 Feed GM BLANK ci re 3FL 20F99801-Electrical Room Condensing Unit N Nt NI I 1 PRELIMINARY to one: JNH OR1° CLEAN WATER SERVICES SHEET TITLE: SHEET: OF: owO;r. .4 o DATE; ELECTRICAL NOT FOR DURHAM AWWTF a, OsN: RSH DWG 900-E-612 PLOT /.11 THIS BAR Is DATE APR 2013 CONSTRUCTION CHIC JKL CAD PLEr. ONE INCH WHEN Clean Water Services CH2MH ILL PHASE 5D2 900-E-612 Z 900 E 612_422389.dgn DRAWING IS Our commitment is de., 20MCC99101 AND 20MCC99102 PLCIP )000( ill APPO:LLC SALE AS SHOWN FULL SCALE. COGENERATION AND BROWN ELEVATIONS REV II Goa DATE BY APVR DESCRIPTOR 25505W Hillsboro Hwy, Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES PRJ r! 6471 ENGR STAMP: if •. • • • • • • • • • • • • • • • • •• •• • • • • •• •• ••• •• • ••• • •• •• • • • • • • • • • • • • • • • •• •• COGENERATOR FACILITY • • • • • ••• • • • • • • • • •• • • • •• • • • • • • • • • 3 • • • • • • 716VCP4501 716DCP4501 - 717VCP6901 ® 0 [CEJ] ® • • • ••• ••• • f„_- ••• ••• • • •• •• [E1] • • • • • • • ••• ••• •• • • i[CE-3] • • • • • ••• f 716VCP4502 716DCP4502 [El] [E1] • l 1 r[E3J [E1] 716NIP4401 7161 ,4501 p� 1 [E2]--.%,........„ ® / Vz [CE-5],(FIBER)J/ [E3] [E1] 716SWGR4401 716MCP4501 L ® [E1] i (DEAD-BUS) [CE-51,(FIBER) 716CMH0101 DIGESTER COMA [CE-5],(FIBER) BROWN GREASE RECEIVING FACILITY [CE-5],(FIBER) [E3] 20LP00703 MANHOLE 715CMH010$ 715CMH0101 715NIP4401 0/ i ® EXST CONDUIT ICE-5],(FIBER) [CE-5],(FIBER) V[EJ [CE-5].(FIBER) a N N `.i W 715LCP6401 I Ui O J o_ a a N SUBSTATION STRUVITE RECOVERY F (EXST) FACILITY o p PGE CONTROL or ICE-51,(FIBER.DEAD-BUS) o' BUILDING (EXST) c. co m N COMMUNICATIONS NETWORK CABLE BLOCK DIAGRAM of NTS oGRN: JNH o CLEAN WATER SERVICES SHEETTrRE. SHEET. ( OF: DWG.: PRELIMINARY )(IS cn C— Y DURHAM AWWTF ELECTRICAL RLGT APR 2013 NOT OsN: RSH DWG I 900-E-620 THIS BAR WHEN CleartWater Services C. ■2M H I LL PHASE 5D2 DATE: 900-E-620 w CAD FILE ONE INCH WHEN i CHIC JKL 900-E-620_422389.dgn Our commitment is dear COMMUNICATIONS NETWORK PLC* xxxX I ZZZZ DRAWING IS COGENERATION AND BROWN LLC SCALE' AS SHOWN FULL SCALE. REVS DATE BY APVR DESCRIPTION 2550 SW Hillsboro Hwy. HIIlsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES CABLE BLOCK DIAGRAM Ze 6471 ENGR STAMP: a. .• •• • • • • •••• •• •• I DUCTBANK 1 ••• • • ••0UCTBPNLL•17•• • • DUCTBANK 10 r r . • • • •• CONDUIT CONDUIT CONDUIT • • • • • • CONDUIT •• SIZE WIRE FILL FROM TO NOTES CONDUIT SIZE WIRE FILL FROM TO NOTES CONDOR SIZE WIRE FILL FROM TO NOTES (NCHES) NO- (NCHES) NO. (NCHES) EXST MANHOLE NEAR FBER TO BE PROVIDED AND INSTALLED BY TI-E 1 4 3k600KCML1#3/DG 716SWGR4401 716GEN4501 PARALLEL FEEDER PARALLEL FEEDER TO 715MCC4401"A"SIDE MAIN 1 2 FBER 7150410102 1 3 •3#250•��&L,1#2G 715LMH0101 715MCC4401 DIGESTER COMPLEX2 DISTRICT 2 4 3#600KCML1#3/OG 716SWGR4401 716GEN4501 PARALLEL FEEDER • _ • r • BREAKER EXST MANHOLE NEAR 3 4 3#SOOKCML1#3/OG 716SWGR4401 716GEN4501 PARALLEL FEEDER • • �• • • •• • PARALLEL FEEDER TO 715MCC4401"A"SIDE MAIN 2 112 6#12,1#12G 715043102 •3 •3#250K L,1#2G 715LMH0101 715MCC4401 DGESTER COMPLEX 2 4 4 3#SOOKCML1#3/OG 716SWGR4401 716GEN4501 PARALLEL FEEDER • • • • • • • • BREAKER 3 1 1/2 3 TYPE 3 EXST MANHOLE NEAR 715043102 5 1 112 SEE CABLE BLOCK 716SWGR4401 716DCP4507 GENERATOR#1 BREAKER CON t BJ F�LCE • •• • • • • PARALLEL FEEDER TO 7151 CC4401"B"SIDE MAIN DIGESTER COMPLEX 2 DIAGRAMS •• 3••• 3 • 5OKgt14L1#2G 715LMi0101 715MCC4401 BREAKER EXST MANHOLE NEAR SEE CABLE BLOCK PARALLEL FEEDER TO 715MCC4401"8"SIDE MAIN 4 2 PULLCORD 7150110102 SPARE 6 1 DIAGRAMS 716SWGR4401 716GEN4501 4 3 3#250KCML1#2G 715U-IO101 715ECC4401 BREAKER DIGESTER COMPLEX 2 •• DUCTBANK 2 DUCTBANK 11 ••• ••• _•• aL B4 1 • • ■ CONDOR CONDUIT • CONDUIT • • • .,*' CDNBuIT D • NO. SIZE WIRE FILL FROM TO NOTES CONDUIT SIZE WIRE FILL FROM TO NOTES • • •••C`1W • • ',WIRE FILL FROM TO NOTES (NCHES) NO. (NCHES) • • • • YO.• (®C S)••• I 1 2 FBER 715CMH0102 715043101 FBER TO BE PROVIDED AND INSTALLED BY THE 1 4 3#600KCML1#3/0G 716SWGR4401 716GEN4502 PARALLEL FEEDER • ••• • • FBER TO BE PROVIDED AND INSTALLED BY T4E DISTRICT 2 4 3#600KCML1#3IOG 716SWGR4401 716GENkt502 PARALLEL FEEDER • 1 2 FBER 716LCP4501 716CMN0101 DISTRICT 2 112 6#12,1#12G 715CMF10102 715CM10101 3 4 3#600KCML1#3/0G 716SWGR4401 716GEN4502 PARALLEL FEEDER 2 2 PULLCORD 716LCP4501 716CMi0101 3 1 12 3TYPE 3 71504.10102 715043101 4 4 3#600KCML1#3/OG 716SWGR4401 716GENM502 PARALLEL FEEDER 3 2 PULLCORD SEE NOTE 7160410131 STUB LP NEAR 716LCP4501 AND CAP _ 4 2 PULLCORD 715CMH0102 715CM-0101 SEE CABLE BLOCK 4 2 PULLCORD SEE NOTE 716CMH0101 STUB LP NEAR 716LCP4501 AND CAP 5 1 112 DIAGRAMS 7165WGR4401 716DCP4502 GENERATOR#2 BREAKER CONTROL INTERFACE DUCTBANK 3 SEE CABLE BLOCK DUCTBANK 19 CONDU7 6 1 DIAGRAMS 716SWGR4401 716GEN4502 CONDUIT SIZE WIRE FILL FROM TO NOTES CONDUIT CONDUIT SVE WIRE FILL FROM TO NOTES (NCHES) DUCTBANK 12 (FICHES) 1 2 FBER 715CM10101 715LCp6401 FBER TO BE PROVIDED AND INSTALLED BY THE CONDOR CONOl11T 1 1 PULLCORD 716SWGR4401(MCP) 716CM-10101 _DISTRICT SIZE WIRE FILL FROM TO NOTES 2 1 PULLCORD 716SWGR4401(MCP) 716CMH0101 2 112 6#12,1#12G 715C1H0101 715LCP6401 (FICHES) 3 112 PULLCORD 716SWGR4401(MCP) 7160410101 3 1 1/2 3TYPE 3 71504-0101 715LCP6401 1 4 PULLCORD 716SWGR4401 716`4-13101 FUTURE ENGINE/GENERATOR716GEN4503 4 1 1/2 PULLCORD 716SWGR4401(MCP) 71601 IO1O1 4 2 PULLCORD 71504-0101 SEE NOTE STUB LIP AND CAP ADJACENT TO 715LCP6401 2 4 PULLCORD 716SWGR4401 7161M-0101 FUTURE ENGINEJGENERATOR716GEN4503 5 3 PULLCORD 716SWGR4401(MCP) 716CM-1O101 3 4 PULLCORD 716SWGR4401 716LM-0101 FUTURE ENGINEIGENERATOR716GEN4503 6 3 PULLCORD 716SWGR4401(MCP) 716CMH0101 DUCTBANK 4 4 4 PULLCORD 716SWGR4401 716LM-0101 FUTURE ENGINE/GENERATOR716GEN4503 CONDUIT FUTURE GENERATOR#3 BREAKER CONTROL DUCTBANK 20 CONDOR 5 112 PULLCORD 716SWGR4401 716`4-0101 SIZE WIRE FILL FROM TO NOTES INTERFACE CONDUIT (INCHES) CONDUIT SIZE WIRE FILL FROM TO NOTES 6 1 PULLCORO 716SWGR4401 716LMH3101 1 4 3#2(15KV),1#2G 100SWGRO101A 7164410102 MAKE CONNECTION TO EXST SWITCHGEAR VIA EXST NO. (INCHES), FIBER TO BE PROVIDED AND INSTALLED BY TFE (600V) MANHOLE NEAR LINEUP DUCTBANK 13 2 4 PULLCORD 100SWGRO101A 716M-10102 MAKE CONNECTION TO EXST SWITCHGEAR VIA EXST CONDOR CONDUIT 1 2 FBER 716041/3101 7150/H0101 DISTRICT MANHOLE NEAR LINEUP SIZE WIRE FILL FROM TO NOTES 2 2 PULLCORD 7160110101 7150410101 3 4 PULLCORD 130SWGR01018 716m410102 MARE CONNECTION TO EXSTSWRCFK3EAR VIA EXST NO. (FICHES) 3 2 PULLCORD 7160410101 715GMt3101 MANFDLE NEAR LINEUP 1 1 112 SEE CABLE BLOCK 716SWGR4401 716DCP4501 4 2 PULLCORD 716CMH0101 715CM3101 4 4 PULLCORD 100SWGRO101B 71614,110102 MAKE CONNECTION TO EXST SWITCHGEAR VIA EXST DIAGRAMS MANHOLE NEAR LINEUP SEE CABLE BLOCK DUCTBANK 21 2 3 DIAGRMIS 716SWGR4401(MCP) 716OCP4501 CONDUIT I DUCTBANK 5 3 1 PULLCORD 716SWGR4401(MCP) 716OCP4501 CONDOR SIZE WIRE FILL FROM TO NOTES CONDUIT 4 1 PULLCORD 716SWGR4401 MCP 716DCP4501 CONDOR (MCP) - (INCHES) SIZE WIRE FILL FROM TO NOTES SEE CABLE BLOCK NO 1 1 PULLCORD 717VCP6901 716L1f3102 (INCHES) 5 1 DIAGRAMS 716SWGR4401 716DCP4502 2 1 PULLCORD 717VCP6901 716`410102 1 4 (I2 V)'1 71616143102 71614•10101 6 3 SERE BLOCK 716SWGR4401(MCP) 716DCP4502 3 1 9#12,3#12G 717VCP6901 716U4-10102 CONDENSATE PLANS(2)AND SKID 2 ENCLOSURE FAN 2 4 PULLCORD 716Mtf10102 716Mrih3101 7 1 PULLCORD 716SWGR4401(MCP) 716DCP4502 4 1 3114,1#86 717VCP6901 716`43102 GAS BLOWER 1 3 4 PULLCORD 716M"f10102 71616413101 8 1 PULLCORD 716SWGR4401(MCP) 716DCP4502 5 1 3#4,tA'8G 717VCP6901 716`4-113102 GAS BLOWER 2 4 4 PULLCORD 716MM10102 716NM10101 SECONDARY CONTROL POWER FROM STARTING 6 1 396,1#W03 717VCP6901 7161M-0102 CHILLER 9 1 2912,1#12G 716SWGR4401(MCP) 716GEN4501 BATTERIES 7 2 14914.1914G 717VCP6901 716`410102 DUCTBANK6 8 1 2#'12,1#12G 716LCP4501 71604113102 SV6903 DUCTBANK 14 9 1 2912,1#12G 716LCP4501 716LM3102 AUTO DRP TRAPS CONDUIT - CONDUIT 10 1 PULLCORD 716LCP4501 716`4-3102 CONDOR CONDUIT SIZE WIRE FILL FROM TO NOTES SIZE WIRE FILL FROM TO NOTES 11 1 PULLCORD 716LCP4501 716LM 3102 N10. (INCHES) NO. (NCHES) 1 4 392(15KV'1 ' 716461.10101 716XFMR4401A CONDUITS CONNECT TO 151(1 SWITCH,CLOSE 1 3 3#250KCML1#2G 7165WGR4401 716LM4i1101 PARALLEL FEEDER TO 715MCC4401"A"SIDE MAW DUCTBANK 22 (600V) COUPLED TO 716XFMR4401A BREAKER CONDUIT CONNECT TO 15KV SWITCH.CLOSE PARALLEL FEEDER TO 715MICC4401'A"SIDE MAIN R SIZE WIRE FILL FROM TO NOTES NO. 2 4 PULLCORD 716MNi0101 716XFMR4401A COUPLED TO 716XFM24401A 2 3 3#250KCML1#2G 716SWGR4401 776`4-0101 BREAKER (INCHES)1 3 24 TYPE 3,1 CAT 6 717VCP6901 716CMi0102 0o DUCTBANK 7 DUCTBANK 15 2 1 1/2 22#14,1#14G 717VCP6901 716CM10102 i"i CONDUIT CONDUIT 3 2 PULLCORD 717VCP6901 716CM-10102 o CONDUIT CONDUIT cq SIZE WIRE FILL FROM TO NOTES SIZE WIRE FILL FROM TO NOTES 4 2 PULLCORD 717VCP6901 716CMH0102 di NO. (INCHES) NO. (NCHES) 1 1 4 PULLCORD 7161M10101 716XFM14401B STUN UP AND CAP AT LOCATION OF FUTURE 15KV 1 3 3#25OKCML 1#26 716SWGR4401 716LMHD101 PARALLEL FEEDER TO 7154004401'B'SIDE MAIN DUCTBANK 23 SWITCH BREAKER CONDUIT S 2 4 PULLCORD 716M*I0101 716X44244016 STOP UP AND CAP AT LOCATION OF FUTURE 15KV 2 3 3#250KCML1#2G 716SWGR4401 716`4-0101 PARALLEL FEEDER TO 71514004401'3-SIDE MAIN CO NDUR SIZE WIRE FILL FROM TO NOTES SWITCH BREAKER NO- (INCHES) 1 1 1/2 PULLCORD 716LM-I0101 ELECTRICAL ROOM STUB U.AND CAP AT LOCATION SHOWN ON ry DUCTBANK 8 DUCTBANK 18 DRAV1IN CONDOR CONDUIT CONDUIT CONDUIT 2 1 1/2 PULLCORD 716`4-0101 ELECTRICAL ROOM STUB LIP AND CAP AT LOCATION SHOWN ON SIZE WIRE FILL FROM TO NOTES SIZE WIRE FILL FROM TO NOTES DRAWINGS _ N NO. (INCHES) NO. (NCHES) STUB LP AND CAP AT LOCATION SHOWN ON 3 112 PULLCORD 716`4-10101 ELECTRICAL ROOM iii 1 31/2 39600KCML1#1/0G 716SWGR4401 716MCC44O1 PARALLEL FEEDER TO"A"SIDE MAN BREAKER 1 3 3#250KCML1#2G 716LM101O1 715`4-10101 PARALLEL FEEDER TO 715MCC4401'A"SIDE MAIN DRAWINGS 2 31/2 3#600KCML1#I/0G 716SWGR4401 7164004401 PARALLEL FEEDER TO°A"SCE MAW BREAKER BREAKER 4 2 PULLCORD 716LMH0101 ELECTRICAL ROOM STUB LIP AND CAP AT LOCATION SHOWN ON I 2 3 3#250KCML7#2G 716`410101 715`4-3131 PARALLEL FEEDER TO 715MCC4401'A'SIDE MAN DRAWINGS I- 0 DUCTBANK9 BREAKER STUB UP AND CAP AT LOCATION SHOWN ON 5 2 PULLCORD 716LM-IO101 ELECTRICAL ROOM a CONDUIT 3 3 3i1250KCML1#2G 716`410101 715`44-13701 PARALLEL FEEDER TO 715MCC4401"B"SIDE MAIN DRAWINGS CONDUIT SIZE WIRE FILL FROM TO NOTES BREAKER STUB LIP AND CAP AT LOCATION SHOWN ON NO 6 2 PULLCORD 716LM-I0101 ELECTRICAL ROOM (INCHES) PARALLEL FEEDER TO 715MCC4401"B"SIDE MAIN DRAWINGS 4 3 39250KCML1#2G 716LMi0101 715`4-0101 BREAKER 1 312 3#600KCML1#1/OG 716SWGR4401 716MCC4401 PARALLEL FEEDER TO"B"SIDE MAIN BREAKER 5 3 PULLCORD 716`4-10101 715`4-0101 2 3112 311600KCML1#1106 716SWGR4401 7164004401 PARALLEL FEEDER TO"13"SIDE MAIN BREAKER 6 3 PULLCORD 7161M-10101 715LM-0101 air' v9 N N O PRELIMINARY ■ MIN: JG at: CLEAN WATER SERVICES SHEETTmE. ELECTRICAL SHEET:)()( OF:x( DWG R: NOT FOR O1 DSN: RSH DWG*, 900-e-640 THIS DURHAM AWWTF PLOT APR 2013 CONSTRUCTION g cw FILE St ONE INCH WHEN CleanWater Services CH2MHILL PHASE 5D2 DATE: qz cHK: JKL 900-E-640 900-E-640_422389.dgn DRAWING IS - Oureommitmeotiselm COGENERATION AND BROWN DUCTBANK SCHEDULE PLC7 )OX( APPO:LLC SCALE AS SHOWN FULL SCALE. ly REV II DATE BY SPAR DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 GREASE RECEIVING FACILITIES Pair 6471 ENGR STAMP: • •• •• •• • • • • •• I S • •• •• • • • S • • • ••• • • •• • • • • • • • • • • • • • • • • •• • •• •• LUMINAIRE SCHEDULE INPUT MANUFACTURER AND CATALOG NO. TYPE VOLTAGE WATTS DESCRIPTION LAMPS MOUNTING • • • • ••• • • • • • • • • •:CI • 1'X 4'HEAVY DUTY INDUSTRIAL FLUORESCENT. HEAVY GAUGE • • ••• • • • • • • • ••Al� I LRHONIA AF70 120 58 COLD ROLLED STEEL CONSTRUCTION. VVHITE ENAMEL 2 T8 32W4100K SUSPENDED REFLECTOR FINISH. VNREGUARD AF10 2 32 120 GEB101S WGAFPV ••• ••• ••• ••• ••• ••• I81 OPEN INDUCTION HIGH BAY. COLD ROLLED STEEL HOUSING, HOLOPHANE HBQ 120 110 HIGH GLOSS BAKED WHAT ENAMEL FINISH. SPECULAR HBQ22 1 100L N1 X32 MVOLTGIB100 1 100W INDUCTION SUSPENDED/SURFACE ••• ••• • • •• •• ALUMINUM REFLECTOR,NORMAL BEAM DISTRIBUTION. LPS841 WG • • • • • • • ••• ••• •• • • • • Cl 1.X 4'MULTI PURPOSE WALL BRACKET. STEEL HOUSING WITH LITHONIA WC 120 • 58 ' ACRYLIC DIFFUSER. WC 2 32 MVOLT GEB101S 2 T8 32W 4100K SURFACE C211 120 34 THONIA WC SIMILAR TO TYPE Cl C1 EXCEPT 1 32W T8 LAMP WC 1 32 MVOLT GEB101S 1 T8 32W 4100K SURFACE WALL MOUNTED INDUCTION AREA LIGHT. DIE-CAST ALUMINUM K1 HOUSING WITH BLACK POWDER COATED FINISH. TEMPERED FD 120 80 GLASS LENS WTH SILICONE GASKET SEAL. 5000K COLOR 1NDI ILSAD 1 70W INDUCTION WALL MOUNT TEMPERATURE. CONTRACTOR SHALL PROVIDE LUMINAIRE LSAD-70E UNIVERSAL BALLAST MOUNTED PHOTOCELL IN THE PROVIDED KNOCKOUT. POLE MOUNTED LED AREA LIGHT. DIE-CAST ALUMINUM I P1 ao 120 145 HOUSING. TYPE 3 DISTRIBUTION MATH BACKLIGHT CONTROL. BETA LED 120 LED LAMPS POLE MOUNT DARK BRONZE FINISH. PROVIDE PHOTOCELL. SQUARE ARE EDG 3MB DA 12 D 120 BZ 350 43K STRAIGHT 20'-0"ALUMINUM POLE I P2 I__I 480 145 SIMILAR TO TYPE P1,EXCEPT 480V. BETA LED 120 LED LAMPS POLE MOUNT ARE EDG 3MB DA 12 D 480 BZ 350 43K X1 NEMA4XEMERGENCY LIGHTING UNR. HEAVY LITHONIA � 120 36 POLYCARBONATE HOUSING AND LENS. INDX1238 H1212 2 12W HALOGEN SURFACE 120 1 THERMOPLASTIC EXIT LIGHT WITH LED LAMPS. MAINTENANCE LITNONIA LONG LIFE LED SURFACE I"® FREE NICKEL CADMIUM BATTERY. UL DAMP LOCATION LISTED. LQM-S-W-3-G-1201277-EL N-SD I I NOTES; 1. FOR LOCATION OF EXTERIOR MOUNTED LUMINAIRES. SEE ARCHITECTURAL ELEVATIONS. 2. FOR CEILING TYPES.SEE ARCHITECTURAL DWGS AND/OR SPECIFICATIONS. I 3. ALL DIMENSIONS INDICATED ARE"NOMINAL DIMENSIONS'. a cp 4. PENDANT MOUNT FIXTURES INDIVIDUAL.FOR CONTINUOUS ROW MOUNTING USE SLOTTED SUPPORT CHANNEL. M5. SYMBOL I • I FLUORESCENT LUMINAIRES WITH FL" DOT INDICATES INTEGRAL H O EMERGENCY BALLAST,SEE a SPECIFICATIONS.CONNECT EMERGENCY BALLAST LAMP(S) SWITCHED,UNLESS OTHERWISE Im NOTED. g 6. LUMINAIRES MARKED AS"24 HR"WILL SWITCHED. 0 7. CONNECT EXIT SIGNS TO CIRCUIT CONNECTED TO w iii LIGHT FIXTURES IN AREA SERVED.CONNECT TO I I- o UNSWITCHED PHASE CONDUCTOR. O J a a ai co th N Tv R u-, _ - - - - PRELIMINARY SHEET TITLE SHEET. OF, DWG e. NOT FOR 0 DRn: JG °R'G CLEDURHAMASWWTFCES Poor APR 2013 CONSTRUCTION di c DATE: ELECTRICAL DATE: a Dsn: RSH Dwcr. 900-E-650 THIS BAR IS `,a[' W r Services C■ ■2MHILL PHASE5D2 900-E-650 DHK JKL CAD FILE N ONE INCH WHEN meti LUMINAIRE SCHEDULE z 900-E-650_422389.dgn DRAWING IS Oure• t.eetisclear COGENERATION AND BROWN PLC* )00(X il APPD:LLC SCALE AS SHOWN FULL SCALE. DESCRIPTION 2550 SW Hillsboro Hillsboro,o n97123-9379 GREASE RECEIVING FACILITIES PGNJe 6471 ENGR STAMP: il BEVY DATE BY APVR