Loading...
Specifications A4 C LO i3 - ere(0©7 TIMWE• Submittal RECEIVED FEB 5 2014 CITY OF TIGARD Prepared For: Date:January 22, 2014 BUILDING DIVISION Josh Pierce Jacobs Heating &Air Conditioning Job Name: Revisions: Whole Foods Tigard OR • RTU-3 to Medium Heat 150/120 MBh • RTU-6 to High Heat 250/203 MBh • RTU-9 to Medium Heat 80/64 MBh • RTU-2 thru 5 changed to 2 position "Motorized damper 0-50%" Notes: • RTU-1 requires a 0-100% economizer for outside air. This can be controlled as a two position damper by adjusting Min and Max outside air at settings at the unit controller potentiometer. Or through BMS programming. • RTU-6 requires a 0-100% economizer for outside air. This can be controlled as a two position damper by adjusting Min and Max outside air at settings at the unit controller potentiometer. Or through BMS programming. Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 10 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop 1 Packaged Gas/Electric Rooftop Units The attached information describes the equipment we propose to furnish for this project,and is submitted for your approval. Trey Clemmer Trane 2021 152nd Avenue NE Redmond, WA 98052-5521 Phone: (425) 586-1673 Fax: (425)643-4314 J::\JOBS111761800421111Whole Foods Tigard OR Submittal Jan 22, 2014.doc Table Of Contents Product Summary 1 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop(Items Al -A10) 3 Tag Data 3 Product Data 3 Performance Data 4 Mechanical Specifications 7 Unit Dimensions 10 Weight, Clearance& Rigging Diagram 27 Accessory 38 Field Wiring 47 Packaged Gas/Electric Rooftop Units(Item B1) 48 Tag Data 48 Product Data 48 Performance Data 48 Mechanical Specifications 50 Unit Dimensions 53 Weight, Clearance&Rigging Diagram 55 Accessory 58 • Whole Foods Tigard OR January 22,2014 Tag Data -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop (Qty: 10) Item Tag(s) Qty Description Model Number Al RTU-1 1 10 Ton R410A PKGD Unitary YHC120E4RYA--D7C1A2BOB00000000000 Gas/Electric 0000000 A2 RTU-2 1 7.5 Ton R410A PKGD Unitary YHC092F4RXA--B0C1A2BOB00000000000 Gas/Electric 0000000 A3 RTU-3 1 7.5 Ton R410A PKGD Unitary YHC092F4RMA--B0C1A2B0B00000000000 Gas/Electric 0000000 A4 RTU-4 1 7.5 Ton R410A PKGD Unitary YHC092F4RXA--BOC1A2BOB00000000000 Gas/Electric 0000000 A5 RTU-5 1 4 Ton R410A PKGD Unitary YHC048E4RXA--BOC1A2BOB00000000000 Gas/Electric 0000000 A6 RTU-7 1 3 Ton R410A PKGD Unitary YHC036E4RXA--D2C1A2B0010000000000 Gas/Electric 0000000 A7 RTU-8 1 3 Ton R410A PKGD Unitary YHC036E4RXA--DOC1A2B0010000000000 Gas/Electric 0000000 A8 RTU-9 1 4 Ton R410A PKGD Unitary YHC048F4RYA--DOC1A2B00100000000000 Gas/Electric 000000 A9 RTU-11 1 7.5 Ton R410A PKGD Unitary YHC092F4RXA--DOC1A2B00100000000000 Gas/Electric 000000 A10 RTU-12 1 7.5 Ton R410A PKGD Unitary YHC092F4RXA--DOC1A2B00100000000000 Gas/Electric 000000 Product Data -3-10 Ton R410A PKGD Unitary Item: A5 Qty: 1 Tag(s): RTU-5 Gas/Electric Rooftop • 4 Ton All Units • Low gas heat stainless steel heat exchanger • DX cooling, gas heat • Motorized damper 0-50% • High efficiency • Dehumidification-hot gas reheat • Convertible configuration • 460/60/3 Item: A6 Qty: 1 Tag(s): RTU-7 • Microprocessor controls • 3 Ton • Hinged panels/2 in pleated filters Mery 8 • Low gas heat stainless steel heat exchanger • Hail guard • Economizer Dry Bulb 0-100% with Barometric • Through the base electrical Relief • Circuit breaker • Optional belt drive motor • Powered convenience outlet • Frostat Item: Al Qty: 1 Tag(s): RTU-1 Item: A7 Qty: 1 Tag(s): RTU-8 • 10 Ton • 3 Ton • Medium gas heat stainless steel heat • Low gas heat stainless steel heat exchanger exchanger • Economizer Dry Bulb 0-100% with Barometric • Economizer Dry Bulb 0-100% with Barometric Relief Relief • Frostat • Multi speed fan • Dehumidification-hot gas reheat Item: A8 Qty: 1 Tag(s): RTU-9 • 4 Ton Item: A2, A4 Qty: 2 Tag(s): RTU-2, RTU-4 • Medium gas heat stainless steel heat • 7.5 Ton Dual compressor exchanger • Low gas heat stainless steel heat exchanger • Economizer Dry Bulb 0-100% with Barometric • Motorized damper 0-50% Relief • Dehumidification-hot gas reheat • Frostat Item: A3 Qty: 1 Tag(s): RTU-3 Item: A9, A10 Qty: 2 Tag(s): RTU-11, RTU-12 • 7.5 Ton Dual compressor • 7.5 Ton Dual compressor • Medium gas heat 3ph • Low gas heat stainless steel heat exchanger • Motorized damper 0-50% • Economizer Dry Bulb 0-100% with Barometric • Dehumidification-hot gas reheat Relief • Frostat FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 3 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Performance Data -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Tags RTU-1 RTU-2 RTU-3 RTU-4 RTU-5 RTU-7 Design Airflow(cfm) 4300 3000 3000 2800 1600 1400 Airflow Application Downflow Downflow Downflow Downflow Downflow Downflow Cooling Entering DB (F) 75.40 75.20 75.30 75.40 73.20 75.30 Cooling Entering WB (F) 61.40 61.10 61.20 61.20 58.60 61.00 Ent Air Relative Humidity (%) 44.87 44.39 44.46 44.19 41.20 43.78 Ambient Temp (F) 90.00 90.00 90.00 90.00 83.00 89.00 Evap Coil Leaving Air Temp (DB) (F) 53.92 52.96 53.07 52.10 49.71 - Evap Coil Leaving Air Temp (DB) (F) 53.92 52.96 53.07 52.10 49.71 52.38 Evap Coil Leaving Air Temp (WB) (F) 51.93 50.52 50.62 49.99 47.27 - Evap Coil Leaving Air Temp (WB) (F) 51.93 50.52 50.62 49.99 47.27 51.33 Cooling Leaving Unit DB (F) 55.88 54.36 54.47 53.50 51.44 53.93 Cooling Leaving Unit WB (F) 52.76 51.13 51.23 50.60 48.08 52.00 Cooling LDB with reheat (F) 73.83 73.73 73.86 74.41 69.40 - Gross Total Capacity (MBh) 113.01 86.67 86.84 85.41 46.83 37.16 Gross Sensible Capacity(MBh) 99.75 72.06 72.02 70.45 40.60 34.66 Gross Latent Capacity(MBh) 13.27 14.61 14.82 14.96 6.24 2.51 Net sensible heat ratio w/reheat on (Number) -0.01 0.10 0.09 0.02 0.42 - Net Total Capacity (MBh) 106.07 83.84 84.01 82.96 44.98 35.67 Net Sensible Capacity(MBh) 92.80 69.23 69.19 68.00 38.74 33.16 Net Sensible Heat Ratio (Number) 0.87 0.83 0.82 0.82 0.86 0.93 Heating EAT(F) 64.00 65.00 64.00 64.00 69.00 63.90 Heating LAT (F) 98.70 94.90 101.30 96.00 97.10 95.90 - Heating Delta T(F) 34.70 29.90 37.30 32.00 28.10 32.00 Input Heating Capacity (MBh) 200.00 120.00 150.00 120.00 60.00 60.00 Output Heating Capacity (MBh) 160.00 96.00 120.00 96.00 48.00 48.00 Output Heating Cap. w/Fan (MBh) 166.94 98.83 122.83 98.45 49.85 49.49 Design ESP (in H2O) 0.500 0.500 0.500 0.500 0.500 0.600 Component SP (in H2O) 0.465 0.250 0.250 0.230 0.210 0.097 Indoor mtr operating power(bhp) 2.48 1.04 1.04 0.91 0.50 0.49 Indoor RPM (rpm) 1543 1143 1143 1089 834 894 Indoor Motor Power(kW) 1.85 0.78 0.78 0.68 0.37 0.37 Outdoor Motor Power(kW) 0.60 0.72 0.72 0.72 0.38 0.22 Compressor Power(kW) 7.11 5.67 5.67 5.66 2.53 2.41 System Power(kW) 9.56 7.16 7.16 7.05 3.28 3.00 SEER @ AHRI (btuh/watt) - - - - 15.00 15.00 IPLV @ AHRI (IPLV) 14.5 14.5 14.5 14.5 - - MCA(A) 22.10 19.90 19.90 19.90 12.30 10.30 MOP (A) 30.00 25.00 25.00 25.00 15.00 15.00 Compressor 1 RLA (A) 8.20 7.10 7.10 7.10 6.20 5.80 Compressor 2 RLA(A) 6.00 4.70 4.70 4.70 0.00 0.00 Evaporator fan FLA (A) 4.30 4.30 4.30 4.30 2.50 2.50 Condenser fan FLA (A) 1.50 2.00 2.00 2.00 1.00 0.60 Evaporator face area(sq ft) 16.65 12.36 12.36 12.36 9.27 7.71 Evaporator rows (Each) 4.00 4.00 4.00 4.00 3.00 3.00 Evaporator fin spacing (Per Foot) 192 192 192 192 192 192 Evaporator face velocity(ft/min) 258 243 243 227 173 182 Min. unit operating weight (Ib) 1369.0 1026.0 1026.0 1026.0 725.0 544.0 Max. unit operating weight (Ib) 1666.0 1291.0 1291.0 1291.0 976.0 767.0 Fan motor heat(MBh) 6.94 2.83 2.83 2.45 1.85 1.49 Reheat Temp Rise (F) 19.91 20.77 20.79 22.31 19.69 - Reheat Capacity (MBh) 92.90 67.60 67.66 67.77 34.18 - Dew Point(F) 50.40 48.55 48.65 48.26 45.08 - Dew Point(F) 50.40 48.55 48.65 48.26 45.08 50.53 Moisture Removal (gal/hr) (gph) 1.50 1.65 1.68 1.69 0.71 - Leaving Unit Rel Humid w/Reheat (%) .43.69 40.93 _40.89 39.57 41.58 - FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 4 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Tags RTU-1 RTU-2 RTU-3 RTU-4 RTU-5 RTU-7 Rated capacity (AHRI) (MBh) 113.00 89.00 89.00 89.00 49.00 37.00 Exhaust fan power(kW) 0.65 0.65 0.65 0.65 0.65 0.65 Refrig charge (HFC-410A) -ckt 1 (Ib) 13.3 6.2 6.2 6.2 12.0 6.2 Refrig charge(HFC-410A) -ckt 2 (Ib) 12.8 4.3 4.3 4.3 0.0 0.0 ASHRAE 90.1 Yes Yes Yes Yes Yes Yes Saturated Suction Temp Circuit 1 (F) 48.51 47.42 47.53 46.62 43.38 47.34 Saturated Discharge Temp Circuit 1 (F) 111.87 110.18 110.21 109.91 97.99 108.05 Saturated Suction Temp Circuit 2 (F) 50.48 49.34 49.44 48.59 0.00 0.00 Saturated Discharge Temp Circuit 2 (F) 108.01 107.55 107.56 107.34 0.00 0.00 IEER () 14.50 14.50 14.50 14.50 - - EER @ AHRI Conditions (EER) 12.5 12.6 12.6 12.6 - Total Static Pressure(in H2O) 0.965 0.750 0.750 _0.730 0.710 0.697 Tags RTU-8 RTU-9 RTU-11 RTU-12 Design Airflow (cfm) 1200 1320 3000 3000 Airflow Application Downflow Downflow Downflow Downflow Cooling Entering DB (F) 75.10 77.40 73.60 73.50 Cooling Entering WB (F) 61.50 63.40 58.60 61.30 Ent Air Relative Humidity (%) 46.03 46.21 40.14 49.90 Ambient Temp (F) 90.00 90.00 89.00 90.00 Evap Coil Leaving Air Temp (DB) (F) 51.83 53.47 51.04 52.68 Evap Coil Leaving Air Temp (WB) (F) 50.58 50.91 47.74 50.82 Cooling Leaving Unit DB (F) 53.42 54.94 52.52 54.07 Cooling Leaving Unit WB (F) 51.27 51.55 48.42 51.42 Gross Total Capacity(MBh) 35.97 46.32 84.56 86.35 Gross Sensible Capacity (MBh) 30.16 34.11 73.10 67.45 Gross Latent Capacity(MBh) 5.81 12.21 11.46 18.89 Net Total Capacity(MBh) 34.66 45.01 81.68 83.47 Net Sensible Capacity(MBh) 28.86 32.80 70.22 64.58 Net Sensible Heat Ratio (Number) 0.83 0.73 0.86 0.77 Heating EAT (F) 65.00 58.50 69.00 69.40 Heating LAT (F) 102.30 103.60 98.90 99.30 Heating Delta T (F) 37.30 45.10 29.90 29.90 Input Heating Capacity (MBh) 60.00 80.00 120.00 120.00 Output Heating Capacity (MBh) 48.00 64.00 96.00 96.00 Output Heating Cap. w/Fan (MBh) 49.30 65.31 98.88 98.88 Design ESP (in H2O) 0.600 0.600 0.600 0.600 Component SP (in H2O) 0.076 0.109 0.170 0.170 Indoor mtr operating power(bhp) 0.42 0.41 1.06 1.06 Indoor RPM (rpm) 938 886 1148 1148 Indoor Motor Power(kW) 0.31 0.30 0.79 0.79 Outdoor Motor Power(kW) 0.22 0.34 0.72 0.72 Compressor Power(kW) 2.44 2.93 5.58 5.69 System Power(kW) 2.97 3.57 7.09 7.19 SEER @ AHRI (btuh/watt) 15.00 - - - IPLV @ AHRI (IPLV) - 0.0 14.5 14.5 MCA (A) 11.00 12.80 19.90 19.90 MOP (A) 15.00 15.00 25.00 25.00 Compressor 1 RLA (A) 5.80 6.20 7.10 7.10 Compressor 2 RLA (A) 0.00 0.00 4.70 4.70 Evaporator fan FLA(A) 3.20 4.00 4.30 4.30 Condenser fan FLA (A) 0.60 1.00 2.00 2.00 Evaporator face area (sq ft) 7.71 9.27 12.36 12.36 Evaporator rows (Each) 3.00 3.00 4.00 4.00 Evaporator fin spacing (Per Foot) 192 192 _192 192 FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 5 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Tags RTU-8 RTU-9 RTU-11 RTU-12 Evaporator face velocity (ft/min) 156 142 243 243 Min. unit operating weight(Ib) 544.0 711.0 1026.0 1026.0 Max. unit operating weight (Ib) 767.0 948.0 1291.0 1291.0 Fan motor heat (MBh) 1.30 1.31 2.88 2.88 Dew Point (F) 49.58 48.87 ,44.77 49.34 Max Available ESP (in H2O) 0.790 0.830 - - Rated capacity (AHRI) (MBh) 37.00 49.00 89.00 89.00 Exhaust fan power(kW) 0.65 0.65 0.65 0.65 Refrig charge (HFC-410A) -ckt 1 (Ib) 6.2 5.2 5.5 5.5 Refrig charge (HFC-410A) -ckt 2 (Ib) 0.0 0.0 4.2 4.2 ASHRAE 90.1 Yes Yes Yes Yes Saturated Suction Temp Circuit 1 (F) 45.88 44.77 45.68 47.03 Saturated Discharge Temp Circuit 1 (F) 108.54 104.88 108.80 110.33 Saturated Suction Temp Circuit 2 (F) 0.00 0.00 '47.64 48.90 Saturated Discharge Temp Circuit 2 (F) 0.00 0.00 106.27 107.75 IEER () - - 14.50 14.50 EER @ AHRI Conditions (EER) - 15.0 12.6 12.6 Total Static Pressure(in H2O) 0.676 0.710 _0.770 _0.770 FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 6 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Mechanical Specifications -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al -A10 Qty: 10 Tag(s): RTU-1, RTU-2, RTU-3, RTU-4, RTU-5, RTU-7, RTU-8, RTU-9, RTU-11, RTU-12 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Two-Inch Pleated Filters 2" pleated media filters shall be available on all models. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 7%-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC(036,048, 060,072, 090, 102, 120); standard on YHC(036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120E, T/YHC092,102, 120E). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3-5 ton units(standard efficiency 3-phase or high efficiency 3-phase with optional motor)are belt driven, FC centrifugal fans with adjustable motor sheaves. 3-5 ton units(1-phase or high efficiency 3-phase) have multispeed, direct drive motors. All 6-8%ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons and 7'%-81/2 (high efficiency) have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Multi-Speed Indoor Fan System Multi-speed indoor fan system is designed for use in applications for meeting the minimum requirement of CA Title 24. This system incorporates a multi-speed fan control to change the speed of the fan to 67% of full airflow based off of compressor stages. FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 7 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. The microchannel type condenser coil is standard for the T/YSC 10 ton models and 7%ton high efficiency models. The microchannel type condenser coil is not offered on the 71/2 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. All-aluminum construction improves re-cyclability. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning.A removable, reversible, double-sloped condensate drain pan with through the base condensate drain is standard. Tool-less Hail Guards Tool-less, hail protection quality coil guards are available for condenser coil protection. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions.The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort.A centralized microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DS!) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts,the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Dehumidification The unit shall be equipped with internally finned, 5/16"copper tubes mechanically bonded to configured aluminum plate fins. The coil shall be 2 row with a minimum of 16 fins per inch. Dehumidification shall be achieved by routing hot refrigerant gas from the discharge line of the compressor through the reheat coil. Hinged Access Doors Sheet metal hinges are available on the Filter/Evaporator, Supply Fan/Heat, and the Compressor/Control Access Doors. Powered or Unpowered Convenience Outlet This is a GFCI, 120v/15amp, 2 plug, convenience outlet, either powered or unpowered. When the convenience outlet is powered, a service receptacle disconnect will be available. The convenience outlet is powered from the line side of the FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 8 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 disconnect or circuit breaker, and therefore will not be affected by the position of the disconnect or circuit breaker. This option can only be ordered when the Through the Base Electrical with either the Disconnect Switch or Circuit Breaker option is ordered. Plenum Fan The following unit shall be equipped with a direct drive plenum fan design (all 10 tons and 7.5-8.5 ton high efficiency units). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Motorized Outside Air Dampers Manually set outdoor air dampers shall provide up to 50 percent outside air. Once set, outdoor air dampers shall open to set position when indoor fan starts. The damper shall close to the full closed position when indoor fan shuts down. Through the Base Electrical Access An electrical service entrance shall be provided allowing electrical access for both control and main power connections inside the curb and through the base of the unit. Option will allow for field installation of liquid-tight conduit and an external field-installed disconnect switch. Through the Base Electrical with Circuit Breaker This option is a thermal magnetic, molded case, HACR Circuit Breaker with provisions for through the base electrical connections. The circuit breaker will be installed in a water tight enclosure in the unit with access through a swinging door. Wiring will be provided from the switch to the unit high voltage terminal block. The circuit breaker will provide overcurrent protection, be sized per NEC and UL guidelines, and be agency recognized by UL/CSA. Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. (Cooling with Electric Heat Only.) Frostat This option is to be utilized as a safety device.The Frostat opens when temperatures on the evaporator coil fall below 10°F.The temperature will need to rise to 50°F before closing.This feature should be utilized in low airflow or high outside air applications (cooling only). FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 9 of 59 installed by Others Whole Foods Tigard OR January 22,2014 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 CONTROL BOX SECTION ACCESS PANEL INDOOR TOP PANEL GAS CONNECTION • DOOR TOP PANEL (SEE NOTE 2) i� ` CONDENSER FAN EVAPORATOR SECTION \I .....„.----/11141141411 . `\ ' ACCESS PANEL 00(m�11 rc} rol))))))l))) CONDENSATE(SEE NOTE 1) I I _ /�re- .--. CONDENSER COIL I II 7 5/8" IINIII ` ,\ o 47 7/8" i % CONDENSER \ !rte COIL SIDE 53 3/4" HORIZONTAL AIR FLOW COMPRESSOR ACCESS PANEL 4 POWER WIRE(SEE NOTE 3) _ PACKAGED GAS/ELECTRICAL ISOMETRIC VIEW X27 9/15 THROUGH THE BASE CONDENSATE 4 3/18" 4 NOTES: 1.ALTERNATE CONDENSATE DRAIN CONNECTION 7 1/ DIA.HOLE •-. 2. NPT GASCON CONNECTION(80 mbh,120 mbh);/7 �\\ __ ____ __ _ 3/4"NPT GAS CONNECTION 150mbh,200mbh,2 50mbh)((I I I I I�■ i 111'))l 3.UNIT POWER WIRE 1 3/8"DIA.HOLE. V\_ 110/ 4.THRU-THE-BASE ELECTRICAL AND GAS IS NOT STANDARD ON ALL UNITS. _ 33" 341 5.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH SUPPLY INSTALLER DOCUMENTS BEFORE INSTALLATION RETURN -_J---- I- - - ti 171/2" - 1712" PLAN VIEW UNIT e sz 1/4" DIMENSION DRAWING A - 9 3J8" I COIL 52 5/16" 50 AB" - 191/4" - - 18 11/16" SUPPLY RETURN 321/4" SERVICE 1 1 HORIZONTAL SIDE I AIR FLOW ■ aiiea■n■i■naii li 4 1/4" 27 9/16" 43/4" - ..11/16" 3/16" - - .162" CONDENSATE DRAIN PACKAGED GAS/ELECTRICAL DIMENSION DRAWING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 10 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 4 s4 ,4,44,4,44 4,11. 4%.,.44%%444444444444b ,iii �0 t��o Y O �di PANEL �„a ACCESS SIDE - \.r>16 - CONDENSER COIL SIDE r----, r---7 CONDENSER L----J L---J COIL SIDE 2 9/16" 0 X )) i _I 6 318 THROUGH THE BASE CONDENSATE THROUGHT THE BASE °°-5 5/8" ELECTRICAL(SEE NOTE 1 AND 2) 47 71r PANEL NOTES. ACCESS SIDE 1.THRU-THE-BASE ELECTRICAL IS NOT STANDARD. VERIFY OPTION IN PRODUCT DATA IN THIS DOCUMENT. 2.VERIFY WEIGHT,CONNECTION,OPTION CONFIGURATION AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION THRU THE BASE ELECTRICAL PLAN/ISO VIEW DRAWING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 11 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 'ELECTRICAL/GENERAL DATA GENERAL 1406) HEATING PERFORMANCE Model: YHC120E Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: N/A Heating Model: 'Medium Unit Secondary Voltage — MCB: N/A Unit Primary Voltage: 460 MFS: N/A Heating Input(BTU): 200.000/140,000 Unit Hertz: 60 Heating Output(BTU): 160,000!112,000 Unit Phase: 3 No.Burners: 4 No.Stages 2 EER 12.5 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: 24.9 MCA: N/A Natural Gas(Min/Max): '4.5/14 MFS: 30.0 MFS: N/A LP(Min/Max) 10.0/14.0 MCB: 30.0 MCB: N/A Gas Pipe Connection Size: 3/4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number '1 Number N/A Number N/A Horsepower. 3.6 Horsepower N/A Horsepower N/A MotorSpeed(RPM): — MotorSpeed(RPM): N/A MotorSpeed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 4.3 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number '2 Number 1 Horsepower 5.13.0 Horsepower 0.75 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 8.2/6.0 Phase: 3 Locked Rotor Amps: 66.0/44.0 Full Load Amps: 1.5 Locked Rotor Amps: 4.8 POWER EXHAUST ACCESSORY k31 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower: N/A Furnished: Yes Factory Charge Motor Speed(RPM): N/A Number 3/2 Circuit#1 14.0 lb Full Load Amps: N/A Recommended 20"x25"x2" Circuit#2 11.8 lb Locked Rotor Amps: N/A 20"x30'x2" NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 12 of 59 Installed by Others - Whole Foods Tigard OR January 22,2014 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A2-A4, A9,A10 Qty: 5 Tag(s): RTU-2, RTU-3, RTU-4, RTU-11, RTU-12 TOP PANEL EVAPORATOR SECTION ACCESS PANEL CONDENSER FAN CONDENSATE DRAIN(ALT) 3/4"-14 NPT DIA HOLE /Jf 45 EIZI. 1) ONDENSER COIL I III 4 1/4 �, `27 5 8 `M , NIT CONTROL WARE 7/8"DIA.HOLE .�� '� SERVICE GAUGE PORT ACCESS 13/8"DIA.HOLE 477/8" o UNIT POWER WIRE 1/2"NPT GAS CONNECTION (80MBH&120MBH) 3/4"NPT GAS CONNECTION —CONTROL AND COMPRESSOR ACCESS PANEL (150MBH,200MBH&250MBH) PACKAGED GAS/ELECTRICAL THROUGH THE ISOMETRIC VIEW BASE CONDENSATE- 418 27 5A!" 1 NOTES: 1.THRU-THE-BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2.VERIFY ALL DIMENSIONS WITH INSTALLER DOCUMENTS - BEFORE INSTALLATION. r—_r_, r"_f_, �Ui, Ms\ `�� ql� 33 `�/ 32 1/8" �� SUPPLY RETURN [ I 1 o-17 117 9 7/8" o-17117 [..7 5!B" PLAN VIEW UNIT DIMENSION DRAWING I 7A3 HORIZONTAL RETURN 32 1/4" AIR FLOW 237/3" SUPPLY V 241/2" 43/4" 9 " 5 51111111 IU -- - 191/4" A 9 3A3" - 16 3/4" - 3 7A3" II 4 1/4" I CONDENSATE 5 _ • 88 5/8" 7 5/8" - - PACKAGED GAS/ELECTRICAL 531/4" DIMENSION DRAWING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 13 of 59 Installed by Others - Whole Foods Tigard OR January 22,2014 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A2-A4, A8-A10 Qty: 6 Tag(s): RTU-2, RTU-3, RTU-4, RTU-9, RTU-11, RTU-12 �llEE tii 3/4"-14 DIA HOLE . .k :000,,, ,,,,,„, CONDENSATE DRAIN o 0 I 27 5/8" \''''''''''''''''>4 3/4" ISOMETRIC-PACKAGED COOLING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 14 of 59 Installed by Others - Whole Foods Tigard OR January 22,2014 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A2 -A5, A8 -A10 Qty: 7 Tag(s): RTU-2, RTU-3, RTU-4, RTU-5, RTU-9, RTU-11, RTU-12 '''--------_, , ,,,, ____p__,---:____ , i a COIL SIDE ( CONDENSER COIL SIDE ——— — THROUGH THE BASE jELECTRICAL ^�/ I (SEE NOTE 1 AND 2) 0 23 E 1 / T .- 3 3/4" / i THROUGHTHE BASE CONDENSATE 5 7/8" o v o 5" NOTES: 1.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD. PANEL VERIFY OPTION IN PRODUCT DATA IN THIS DOCUMENT. ACCESS SIDE 2.VERIFY WEIGHT,CONNECTION,OPTION CONFIGURATION AND ALL DIMENSION WITH INSTALLER DOCUMENTS - BEFORE INSTALLATION THRU THE BASE ELECTRICAL PLAN/ISO VIEW DRAWING FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 15 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A2,A4 Qty: 2 Tag(s): RTU-2, RTU-4 ELECTRICAL/GENERAL DATA 'GENERAL 1264X6) HEATING PERFORMANCE Model: YHC092F Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: N/A Heating Mode. ' Unit Primary Voltage 460 MFS: N/A g r Low Unit Secondary Voltage — MCB: N/A Heating Input(BTU): 120.000 Unit Hertz: 60 Heating Output(BTU): 96,000 Unit Phase. 3 No Burners: 3 No.Stages 1 EER 12.6 Standard Motor Field Installed Oversized Motor Gas Inlet Pressure MCA: '19.9 MCA: N/A Natural Gas(Min/Max): '4.5/14 MFS: 25.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 25.0 MCB: N/A Gas Pipe Connection Size: 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number '1 Number N/A Number N/A Horsepower 3.6 Horsepower N/A Horsepower N/A Motor Speed(RPM): — Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 4.3 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR _ Number '2 Number '1 Horsepower 4.1/2.4 Horsepower 0.75 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 7.1/4.7 Phase: 1 Locked Rotor Amps: 52.0/38.0 Full Load Amps: 2.0 Locked Rotor Amps: 6.2 POWER EXHAUST ACCESSORY 13 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower. N/A Fumished: Yes Factory Charge Motor Speed(RPM): N/A Number 4 Circuit#1 6.2 lb Full Load Amps: N/A Recommended 20"x25x2" Circuit#2 4.3 lb Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. • FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 16 of 59 Installed by Others - Whole Foods Tigard OR January 22,2014 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A3 Qty: 1 Tag(s): RTU-3 ELECTRICAL/GENERAL DATA GENERAL 12/41(6) HEATING PERFORMANCE Model: YHC092F Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage. 414-506 MCA. N/A Heating Model: Medium Unit Pnmary Voltage: 460 MFS: N/A Unit Secondary Voltage — MCB: N/A Heating Input(BTU): 150,000/105,000 Unit Herz: 60 Heating Output(BTU): 120.000/84,000 Unit Phase: 3 No Burners: 3 No Stages 2 EER 12.6 Standard Motor Field Installed Oversized Motor Gas Inlet Pressure MCA: '19.9 MCA: N/A Natural Gas(Min/Max): '4.5/14 MFS: 25.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 25.0 MCB: N/A Gas Pipe Connection Size: 3/4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number '1 Number N/A Number N/A Horsepower 3.6 Horsepower N/A Horsepower N/A Motor Speed(RPM): — Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps. 4.3 Full Load Amps. N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number '2 Number 1 Horsepower: 4.1/2.4 Horsepower 0.75 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 7.1/4.7 Phase: 1 Locked Rotor Amps: 52.0/38.0 Full Load Amps: 2.0 Locked Rotor Amps: 6.2 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower N/A Furnished: Yes Factory Charge Motor Speed(RPM): N/A Number 4 Circuit#1 6.2 lb Full Load Amps: N/A Recommended 20"x25"x2" Circuit#2 4.3 lb Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Fumished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 17 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item:A5,A8 Qty: 2 Tag(s): RTU-5, RTU-9 /—TOP PANEL EVAPORATOR SECTION ACCESS PANEL CONDENSER FAN CONDENSATE DRAIN(ALT) (.-------.....---,.."- ij. ,1��111 3/4"-14 NPT DIA HOLE %`��f,I�� CONDENSER COIL 47/'4�.j\ — \' // �/ UNIT CONTROL WIRE 7/8"DIA.HOLE 47 7m• \� ° /SERVICE GAUGE PORT ACCESS 1 3/8"DIA.HOLE -41114111.-4a _° / NIT POWER WIRE y4 12"NPT GAS CONNECTION ONTROL AND COMPRESSOR ACCESS PANEL (80MBH&120MBH) 3/4"NPT GAS CONNECTION (150MBH,200MBH&250MBH) THROUGH THE BASE 27 5/8• CONDENSATE \ —1 b NOTES: -41/8" f'" yp 1.THRU-THE-BASE ELECTRICAL AND GAS IS NOT STANDARD ON L:I 4 ALL UNITS. 2.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION r-- --1 r-- --1 ���r� X% Va":41 ) ■1•00°. SUPPLY RETURN L9l/FL _4.n 1n I..._3 5re" PLAN VIEW UNIT °°° DIMENSION DRAWING F----- I > • I RETURN 32 114" 407/8" HORIZONTAL SUPPLY 23 7/8" I AIR FLOW I 181n"i, 0 0 I 0 0 L� 0 0 1�4 3/4" 9 5i/8"5 4" e y LJ a19 1/4" 9 3/8" X18 3/4" 3 7/8• 4 1/4 ■ r�- CONDENSATE 55/8" 7 5/8" 88 5/8 53 114" PACKAGED GAS/ELECTRICAL DIMENSION DRAWING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 18 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A5 Qty: 1 Tag(s): RTU-5 'ELECTRICAL/GENERAL DATA GENERAL(2x4/61 HEATING PERFORMANCE Model: YHC048E Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: N/A Model: 'Low Unit Primary Voltage: 460 MFS: N/A Heating Heating M Moue(BTU): Lo 60,000 Unit Secondary Voltage — MCB: N/A Unit Hertz: 60 Heating Output(BTU): 49,000 Unit Phase: 3 No.Burners: 2 No Stages 1 SEER 15 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: MCA N/A Natural Gas(Min/Max): '4.5/14.5 MFS: MFS: N/A LP(Min/Max) 11.0/14.0 MCB: MCB: N/A Gas Pipe Connection Size: 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number '1 Number N/A Number N/A Horsepower 1.0 Horsepower N/A Horsepower N/A Motor Speed(RPM): — Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 2.5 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: 16.1 Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR _ Number '1 Number '1 Horsepower 3.5 Horsepower 0.40 Phase. 3 Motor Speed(RPM): 1075 Rated Load Amps: 6.2 Phase: 1 Locked Rotor Amps: 41 0 Full Load Amps: 1.0 _ Locked Rotor Amps: 2.8 POWER EXHAUST ACCESSORY 13i FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Tom: Throwaway Horsepower N/A Furnished: Yes Factory Charge Motor Speed(RPM). N/A Number 4 Circuit#1 11.0 Full Load Amps: N/A Recommended 16"x25"x2" Circuit#2 N/A Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only 2 Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 19 of 59 Installed by Others - Whole Foods Tigard OR January 22,2014 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A6,A7 Qty: 2 Tag(s): RTU-7, RTU-8 TOP PANEL EVAPORATOR . .: ,N%'''''' ''•SECTION ACCESS PANEL CONDENSER FAN ////�l �:111 CONDENSATE DRAIN(ALT) { (14.0���,,�� \`` �9 3!4"-14 NPT DIA HOLE `� ,/ •NDENSER COIL 41/4" �;\ 239/18`" \,,_ '/ \\ Il 0, UNIT CONTROL WIRE 7/8"DIA.HOLE 421/4" lilt' SERVICE GAUGE PORT ACCESS 1 3/8"DIA.HOLE NIT POWER WIRE CONTROL AND COMPRESSOR ACCESS PANEL 1/2"NPT GAS CONNECTION THROUGH THE BASE CONDENSATE NOTES: \\NI X 12"—. S 1 THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2.VERI FY WEIGHT,CONNECTION,AND ALL DIMENSION WITH ( 43118" INSTALLER DOCUMENTS BEFORE INSTALLATION ` 4 rilIN le >>1 , i K`�I• • 24' ..IJJ� 118• RETURN _`�' SUPPLY I —'�I I—� ---- 4" X15 1/2' 9 1/4" a 14' 1 3 5/8" PLAN VIEW UNIT II�� DIMENSION DRAWING — RETURN 361/4" 23 1/4" HORIZONTAL SUPPLY 14 314" AIR FLOW 20114" 9 516" ■' •I•=■1•_s�lt•Z.)•�4" C 8 5 p" �li����)♦ -171/4" 87/8" - 131/4 - 33/18" 41/4" - II 69 7/8" 5 9116" CONDENSATE 7 5!8" 441/4" PACKAGED GAS/ELECTRICAL DIMENSION DRAWING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 20 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A6,A7 Qty: 2 Tag(s): RTU-7, RTU-8 • RETURN ♦a 3!4"-14 NPT 411017.1° DRAIN CONNECTION 23 9116" 1/4" ISOMETRIC-PACKAGED COOLING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 21 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A6, A7 Qty: 2 Tag(s): RTU-7, RTU-8 ■ IN • 0 PANEL / ACCESS SIDE aO / CONDENSER COIL SIDE r----n r._---__I I I I I I I I I I I I I I I �___J I I I I CONDENSER COIL SIDE THROUGH THE BASE ELECTRICAL (SEE NOTE 1 AND 2) 2 13/1�C] I __ A 311/16" THROUGH THE BASE 4 7/6 MI CONDENSATE 5 1/16" NOTES: 1.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD. VERIFY OPTION IN PRODUCT DATA IN THIS DOCUMENT. PANEL 2.VERIFY WEIGHT,CONNECTION,OPTION CONFIGURATION AND ' ACCESS SIDE ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION THRU THE BASE ELECTRICAL PLAN/ISO VIEW DRAWING FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 22 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A6 Qty: 1 Tag(s): RTU-7 'ELECTRICAL/GENERAL DATA 'GENERAL i2 aMSi HEATING PERFORMANCE Model: YHC036E Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: N/A Heating Model: 'Low Unit Pnmary Voltage. 460 MFS: N/A Heating Mode l BTU): Low 60,000 Unit Secondary Voltage 60 MCB: N/A Heating Output(BTU): 48,000 Unit Hertz: 30 No.Burners: 2 Unit Phase. 3 No Stages 1 SEER 15.0 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: '10.3 MCA: N/A Natural Gas(Min/Max): '4.5/10.5 MFS: 15.0 MFS: N/A LP(Min/Max) 10.0/14.0 MCB: 15.0 MCB: N/A Gas Pipe Connection Size: 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number '1 Number N/A Number N/A Horsepower 1.0 Horsepower N/A Horsepower N/A Motor Speed(RPM): — Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 2.5 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: 16.1 Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number '1 Number '1 - Horsepower: 2.7 Horsepower 0.20 Phase: 3 Motor Speed(RPM): 1075 Rated Load Amps: 5.8 Phase: 1 Locked Rotor Amps: 38.0 Full Load Amps: 0.6 Locked Rotor Amps: 1.3 POWER EXHAUST ACCESSORY iii FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower: N/A Furnished: Yes Factory Charge Motor Speed(RPM): N/A Number 2 Circuit#1 7.9 Full Load Amps: N/A Recommended 20"x30"x2" Circuit#2 N/A Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 23 of 59 Installed by Others - Whole Foods Tigard OR January 22,2014 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A7 Qty: 1 Tag(s): RTU-8 ELECTRICAL/GENERAL DATA T— GENERAL tzpapel HEATING PERFORMANCE Model: YHC036E Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: NIA Heating Model: 'Low Unit Primary Voltage. 460 MFS: N/A Unit Secondary Voltage — MCB: N/A Heating Input(BTU): 60.000 Unit Hertz: 60 Heating Output(BTU): 48,000 Unit Phase: 3 No.Burners: 2 No.Stages 1 SEER 15.0 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: '11.0 MCA: N/A Natural Gas(Min/Max): '4.5/10.5 MFS: 15.0 MFS: N/A LP(Min/Max) 10.0/14.0 MCB: 15.0 MCB: N/A Gas Pipe Connection Size: 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number '1 Number N/A Number N/A Horsepower 0.75 Horsepower N/A Horsepower N/A Motor Speed(RPM): — Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 1 Phase N/A Phase N/A Full Load Amps: 3.2 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR _ Number '1 Number '1 Horsepower 2.7 Horsepower 020 Phase: 3 Motor Speed(RPM): 1075 Rated Load Amps: 5.8 Phase. 1 Locked Rotor Amps: 38.0 Full Load Amps: 0.6 Locked Rotor Amps: 1.3 POWER EXHAUST ACCESSORY 131 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type. Throwaway Horsepower N/A Furnished: Yes Factory Charge MotorSpeed(RPM): N/A Number 2 Circuit#1 7.9 Full Load Amps: N/A Recommended 20"x30"x2" Circuit#2 N/A Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only 2.Refngerant charge is an approximate value For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6 EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S Inc.dba Trane/ Equipment Submittal Page 24 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Unit Dimensions -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A8 Qty: 1 Tag(s): RTU-9 'ELECTRICAL/GENERAL DATA GENERAL 1Zx4Xfil HEATING PERFORMANCE Model: YHC048F Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506F MCA: N/A m Model: 'Medium Unit Primary Voltage. 460 MFS: N/A Heating Heating M Mode(BTU): Media Unit Secondary Voltage — MCB: N/A Unit Hertz: 60 Heating Output(BTU): 64,000 Unit Phase: 3 No Burners: 2 No.Stages 1 SEER 15 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: 12.8 MCA: N/A Natural Gas(Min/Max): 4.5/14.5 MFS: 15.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 15.0 MCB: N/A Gas Pipe Connection Size: 12" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number '1 Number N/A Number N/A Horsepower 1.0 Horsepower N/A Horsepower N/A Motor Speed(RPM): — Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 1 Phase N/A Phase N/A Full Load Amps: 7.6 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amos: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR _ Number '1 Number 1 Horsepower. 3.5 Horsepower 0.40 Phase: 3 Motor Speed(RPM): 1075 Rated Load Amps: 6.2 Phase: 1 Locked Rotor Amps: 41.0 Full Load Amps: 1.0 _ Locked Rotor Amps: 2.8 POWER EXHAUST ACCESSORY i3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type. Throwaway Horsepower N/A Furnished. Yes Factory Charge Motor Speed(RPM): N/A Number 4 Circuit#1 5.1 Full Load Amps: N/A Recommended 16"x25"x2' Circuit#2 N/A Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 25 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Unit Dimensions-3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A9,Al0 Qty: 2 Tag(s): RTU-11, RTU-12 • ELECTRICAL/GENERAL DATA GENERAL 12/4x6) HEATING PERFORMANCE Model: YHC092F Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage. 414-506 MCA: N/A Model: 'Low Unit Primary Voltage: 460 MFS: N/A Heating Heating M Mode(BTU): low Unit Secondary Voltage — MCB: NIA Heating Output(BTU): 96.000 Unit Phase: 3 Unit Hertz: 60 No.Burners: 3 s No.Stages 1 EER 12.6 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: '19.9 MCA: N/A Natural Gas(Min/Max): '4.5/14 MFS: 25.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 25.0 MCB: N/A Gas Pipe Connection Size: 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number .1 Number N/A Number N/A Horsepower 3.6 Horsepower N/A Horsepower N/A MotorSpeed(RPM): — Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 4.3 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number '2 Number '1 Horsepower 4.1/2.4 Horsepower 0.75 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 7.1/4.7 Phase: 1 Locked Rotor Amps: 52.0/36.0 Full Load Amps: 2.0 Locked Rotor Amps: 6.2 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower N/A Furnished: Yes Factory Charge Motor Speed(RPM): N/A Number 4 Circuit#1 5.5 lb Full Load Amps: N/A Recommended 20"x25"x2" Circuit#2 4.2 lb Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5 Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 26 of 59 Installed by Others - Whole Foods Tigard OR January 22,2014 Weight, Clearance & Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 lb • MOTORIZED OUTSIDE AIR DAMPER 0 MANUAL OUTSIDE AIR DAMPER .J BAROMETRIC RELIEF • �`�`` OVERSIZED MOTOR to-d BELT DRIVE MOTOR iat. 11 POWER EXHAUST . rkwyjigij THROUGHT THE BASE ELECTRICAL/GAS(FIOPS) 13 0 Ib \ UNIT MOUNTED CIRCUIT BREAKER(FIOPS) 5.0 lb `� UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) 50.0 lb Q HINGED DOORS(FIOPS) 12.0 lb — CD/ 0 HAIL GUARD 30.0 lb �f SMOKE DETECTOR,SUPPLY/RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER 6.0 lb REHEAT 53.0 lb ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET AO 386.0 lb © 2990 lb (E)LENGHT (F)WIDTH 1563.01b 1369.01b O 379.0 lb OD 305.0 lb 49" 28" NOTE: 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2.TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3.BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT.TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE<5 LBS. (: 4 a�\\\\� ' I " \ ,___ „ ,..: , ,..., ,,,,„,„ .... 4,,,,,,_--- ,,,,-- , „„.._,,,,,,. N \ ' \\,[� \\\\ � F E a \ �l� PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 27 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Weight, Clearance & Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 36" CLEARANCE 48" 111 ll!! CLEARANCE 48" \ RETURN ill DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" _ CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ROOF OPENING I I UNIT OUTLINES I I 46" 63 3/16" 46" --i I I 99 11/16" PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 28 of 59 Installed by Others - Whole Foods Tigard OR January 22,2014 Weight, Clearance& Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A2,A4 Qty: 2 Tag(s): RTU-2, RTU-4 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER MOTORIZED OUTSIDE AIR DAMPER 30.0 lb © 0 MANUAL OUTSIDE AIR DAMPER 1 BAROMETRIC RELIEF OVERSIZED MOTOR �� BELT DRIVE MOTOR t 014POWER EXHAUST ` THROUGHT THE BASE ELECTRICAUGAS(FIOPS) 13 0Ib `\J UNIT MOUNTED CIRCUIT BREAKER(FIOPS) 5.0Ib �`� UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) 38.0 lb HINGED DOORS(FIOPS) 12.0 lb B A \O HAIL GUARD 20.0 lb SMOKE DETECTOR,SUPPLY/RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER 6.0 lb REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET ©A 340.0 lb © 249.0 lb (E)LENGHT (F)WIDTH 1124.0 lb 1026.0 lb © 233.0 lb OD 204.0 lb 41" 23" NOTE 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY 2.TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3.BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT.TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE<5 LBS. '-.,•,,, ,1 r-,---.- —rp""■., . E 44-4400440 1., o • ,% PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Fumished by Trane U.S. Inc. dba Trane/ Equipment Submittal Page 29 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Weight,Clearance&Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A2-A5,A8-A10 Qty: 7 Tag(s): RTU-2, RTU-3, RTU-4,RTU-5, RTU-9, RTU-11, RTU-12 CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 36" CLEARANCE 48" (AtrZa \ . 7 , :t% ilia\ h, IA ETURN DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE---- --- - --- 7 ROOF OPENING � UNIT OUTLINE- II 1 I q6" 531/4" ___ _ __ 1_ _____L_____IL h_ L4.6" I I 88 5/8" PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 30 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Weight, Clearance& Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A3 Qty: 1 Tag(s): RTU-3 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER MOTORIZED OUTSIDE AIR DAMPER 30.0 lb © C) MANUAL OUTSIDE AIR DAMPER /"' BAROMETRIC RELIEF OVERSIZED MOTOR ....,,tilt BELT DRIVE MOTOR t � POWER EXHAUST �"��```r�Ill�� THROUGHT THE BASE ELECTRICAUGAS(FIOPS) 13.0 lb ` J J UNIT MOUNTED CIRCUIT BREAKER(FIOPS) 5.0 lb �`� UNIT MOUNTED DISCONNECT(FLOPS) POWERED CONVENIENCE OUTLET(FIOPS) 38.0lb Q „ ,� HINGED DOORS(FLOPS) 12.0 lb \© HAIL GUARD 20.0 lb Cf SMOKE DETECTOR,SUPPLY/RETURN NOVAR CONTROL PACKAGED GAS/ELECTRICAL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET ©A 340.01b © 249.0 lb (E)LENGHT (F)WIDTH 1124.0 lb 1026.0 lb ©e 233.0 lb I 204.0 lb 41” 23" NOTE. 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2.TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3.BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT.TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE<5 LBS. 4 • \�\\\.\ • E `\�®/0 \;\\\ # F '*,. , 1"7. PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 31 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Weight, Clearance & Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A5 Qty: 1 Tag(s): RTU-5 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER MOTORIZED OUTSIDE AIR DAMPER 30.0 lb Q MANUAL OUTSIDE AIR DAMPER N.\� J BAROMETRIC RELIEF OVERSIZED MOTOR■ BELT DRIVE MOTOR ���rr I �l 1 POWER EXHAUST " II�JJJ THROUGHT THE BASE ELECTRICAUGAS(FIOPS) 13.0 Ib ameme■ `%,�� UNIT MOUNTED CIRCUIT BREAKER(FIOPS) 5.0 lb �� UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) 38.0 lb e.,� HINGED DOORS(FIOPS) 12.0 lb ©' © [TAIL GUARD 20.0 lb SMOKE DETECTOR,SUPPLY/RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER 6 0 lb REHEAT 25.0 lb ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET © 238.0 lb © 148.0 lb (E)LENGHT (F)WIDTH 8580 lb 763.0 lb © 200.0 lb I 176.0 lb 40" 23" NOTE. 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2.TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. ! 3.BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT.TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE<5 LBS. ill'* -„, ,,,....4\---Ai- \,..., 4, , - -.,..,14 NI E \ + y ' F PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 32 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Weight, Clearance & Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A6 Qty: 1 Tag(s): RTU-7 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 26.0 lb �^ MOTORIZED OUTSIDE AIR DAMPER O. MANUAL OUTSIDE AIR DAMPER `�C BAROMETRIC RELIEF OVERSIZED MOTOR �� BELT DRIVE MOTOR 31.0lb � POWER EXHAUST ......_ ��rr�, >1 ��```O�I'��� THROUGHT THE BASE ELECTRICAL/GAS(FIOPS) 8.0 lb `� UNIT MOUNTED CIRCUIT BREAKER(FIOPS) 5.0 lb `` UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) 38.0 lb ,(> .,.,/., HINGED DOORS(FIOPS) 10.0 lb B i \O HAIL GUARD 12.0 lb A SMOKE DETECTOR,SUPPLY/RETURN NOVAR CONTROL PACKAGED GAS/ELECTRICAL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER 4.0 lb REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET OA 178.01b © 126.0 lb (E)LENGHT (F)WIDTH 676.0 lb 606.0 lb © 162.0 lb OD 139.0 lb 33" 19" NOTE. 1 CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2 TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. i 3.BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT.TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE<5 LBS. \\ ' „,„1,.,. 4,•::::----- -_-.-- -_ ,_____;:-_;-=)x • , E p� F ! a PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 33 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Weight, Clearance&Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A6,A7 Qty: 2 Tag(s): RTU-7, RTU-8 CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 36" CLEARANCE 48" .ia\ \ \ RETURN ,t2. ,,,,.,,,, _,_7000°,___,„-- °°- . DOWN FLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ---1- 7 ROOF OPENING 1 I UNIT OUTLINE I I 3T' 441 R" LL, I I ——J 40" 68 3/16" PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING FLD=Furnished by Trane U.S.Inc.dba Trane I Equipment Submittal Page 34 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Weight, Clearance & Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A7 Qty: 1 Tag(s): RTU-8 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 26.0 lb MOTORIZED OUTSIDE AIR DAMPER Q D MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR t�� BELT DRIVE MOTOR ekit,51111 POWER EXHAUST �L1�"`\� UJJJ�� THROUGHT THE BASE ELECTRICAL/GAS(FIOPS) _ 8.0 lb `\``` UNIT MOUNTED CIRCUIT BREAKER(FIOPS) 5 0 lb `� UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) 38.0 lb :\ HINGED DOORS(FIOPS) 10.0 lb � ,' O HAIL GUARD 12.0 lb SMOKE DETECTOR,SUPPLY I RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL J CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER 4.0 lb REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET OA 178.OIb © 126.0 lb (E)LENGHT (F)WIDTH 6769 lb 606.0 lb OB 162.0 lb OD 139.0 lb 33" 19" NOTE: 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY 2.TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. } 3 BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT.TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE<5 LBS. �\ ������//ice .��`i I. °, 'Y PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 35 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Weight, Clearance& Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A8 Qty: 1 Tag(s): RTU-9 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 lb MOTORIZED OUTSIDE AIR DAMPER Q 0 MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF J OVERSIZED MOTOR ���� BELT DRIVE MOTOR / �� POWER EXHAUST 1���r ���11 111 � �1�\\``` 1 f THROUGHT THE BASE ELECTRICAUGAS(FIOPS) 13.0 lb `\``````J UNIT MOUNTED CIRCUIT BREAKER(FIOPS) 5.0Ib ```� UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) 38.0 lb ` HINGED DOORS(FIOPS) 12.0 lb O HAIL GUARD 20.01b SMOKE DETECTOR,SUPPLY I RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER 6.0 lb REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS . CENTER OF GRAVITIY SHIPPING NET OA 226.0 lb © 144.0 lb (E)LENGHT (F)WIDTH 806.0 lb 711.01b © 199.0 lb OD 143.0 lb 44" 22' NOTE: 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY 2.TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3.BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT.TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT, 4.WEIGHTS FOR OPTIONS NOT LISTED ARE<5 LBS.4:40.=______-_ ,,..., „„, „„ .:\., ,.......,:, E \`®/0 ,\\. / / F PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 36 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Weight, Clearance & Rigging Diagram -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A9, A10 Qty: 2 Tag(s): RTU-11, RTU-12 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 lb MOTORIZED OUTSIDE AIR DAMPER © 0D MANUAL OUTSIDE AIR DAMPER ‘� VI BAROMETRIC RELIEF OVERSIZED MOTOR rill"� BELT DRIVE MOTOR POWER EXHAUST ��"``Offl�� THROUGHT THE BASE ELECTRICAL/GAS(FIOPS) 13.0 lb �`\```�j UNIT MOUNTED CIRCUIT BREAKER(FIOPS) 5.0 lb `� UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) 38.0 lb <9� HINGED DOORS(FIOPS) 12 0 lb HAIL GUARD 20.0 lb SMOKE DETECTOR,SUPPLY/RETURN NOVAR CONTROL PACKAGED GAS/ELECTRICAL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER 6.0 lb REHEAT ROOF CURB BASIC UNIT WEIGHTS L CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET 340.01b © 249.0 lb (E)LENGHT (F)WIDTH - 1124.0 lb 1026.01b • OB 233.0 lb OD 204.0 lb 41" 23" NOTE: 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2.TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. ! 3.BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT.TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE<5 LBS. lisop. 4 `■iv-i__,;),ini) : -.1. mil , . ...„, , , ....\, ...... ....„ .„..." E `\® oo /�yy PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 37 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 ==== 7 n wJy / / \ \ \ / / \ \ / \ / ---r\i- ---- N / '1713!18" 221/2" SWING DIAMETER-HINGED DOOR(S)OPTION ACCESSORY FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 38 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 • Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-1 r�//l/iii \1 , • ii , IIILL ,,,„, ECONOMIZER HOOD ....... .... .. ....... r ....... ....... ....... ....... ....... ....... ECONOMIZER HOOD r Y .... ... ..... ° 6 7/8„ 00 MOM 00 16 3/4" ECONOMIZER HOOD ACCESSORY FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 39 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A2 -A5, A8 -A10 Qty: 7 Tag(s): RTU-2, RTU-3, RTU-4, RTU-5, RTU-9, RTU-11, RTU-12 ^ ; _, =i ISft1I,$1)) 11...01/ ---F\--'z,3/W '34 5/W SWING DIAMETER-HINGED DOOR(S)OPTION ACCESSORY FLD=Furnished by Trane U.S Inc.dba Trane/ Equipment Submittal Page 40 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A5 Qty: 1 Tag(s): RTU-5 I loso MOTORIZED OUTSIDE AIR HOOD 1 —MOTORIZEDOUTSIDEAIR HOOD o Y 6 7/6" 00 00 16 3/4" ACCESSORY- MOTORIZED OUTSIDE AIR HOOD FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 41 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A6,A7 Qty: 2 Tag(s): RTU-7, RTU-8 wont vow 04 ii)43 I I11 I / 1 / \ 16' 17 7/8" '22 1/4" SWING DIAMETER-HINGED DOOR(S)OPTION ACCESSORY FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 42 of 59 installed by Others _ Whole Foods Tigard OR January 22,2014 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A6,A7 Qty: 2 Tag(s): RTU-7, RTU-8 c___ J IL 'Ill,, [2:221 kek ECONOMIZER HOOD BAROMETRIC RELIEF HOOD BAROMETRIC RELIEF HOOD 4 4 4II 6 15/16" 9 1/8" ACCESSORY-BAROMETRIC RELIEF DAMPER HOOD FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 43 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A6,A7 Qty: 2 Tag(s): RTU-7, RTU-8 (CM'��l% ECONOMIZER HOOD ECONOMIZER 1/4" HOOD o 6 00 mom 8e ti 12 1/2" ACCESSORY-ECONOMIZER HOOD FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 44 of 59 Installed by Others . Whole Foods Tigard OR January 22,2014 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A8 -A10 Qty: 3 Tag(s): RTU-9, RTU-11, RTU-12 .0,aQ1\' K ,i \� / �� —ECONOMIZER HOOD BAROMETRIC RELIEF HOOD) BAROMETRIC RELIEF HOOD\ AI 7 3/4" d 17" ACCESSORY-BAROMETRIC RELIEF DAMPER HOOD FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 45 of 59 Installed by Others . Whole Foods Tigard OR January 22,2014 Accessory -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: A8 -A10 Qty: 3 Tag(s): RTU-9, RTU-11, RTU-12 .' ,,, tttlt>ol ''''<..,1 OIL N ECONOMIZER HOOD Ilk IE CONOMIZER HOOD o 6 7/8" 00 00 L16 3/4" ACCESSORY-ECONOMIZER HOOD FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 46 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Field Wiring -3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al -A10 Qty: 10 Tag(s): RTU-1, RTU-2, RTU-3, RTU-4, RTU-5, RTU-7, RTU-8, RTU-9, RTU-11, RTU-12 1 Lt L2 L3 HTB1 I l • B � 000 o °7° ZONE SENSOR WIRE TABLE WIRE SIZE MAXIMUM WIRE LENGTH 22 GAUGE 1800" 20 GAUGE 3000" 18 GAUGE 4500" 16 GAUGE 7200" 14 GAUGE 11700" NOTE: 1.All wiring and devices shown dashed to be supplied and installed by the customer in accordance with national and local electrical codes. 2.Low voltage control wiring must not be run in conduit with power wiring. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 47 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Tag Data - Packaged Gas/Electric Rooftop Units (Qty: 1) Item Tag(s) Qty Description Model Number B1 RTU-6 1 12.5 Ton Packaged Unitary YHD150F4RZA--D7C1A2B0010000000000000 Gas/Elec 0000 Product Data - Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-6 • Gas/Electric • High efficiency • Downflow • 12.5 Ton • 460/60/3 • Reliatel • Gas Heat- SS Ht Ex- High • Economizer Dry Bulb 0-100%with barometric relief • Two speed fan standard motor • Hinged panels/2" Pleated Filters Mery 8 • Hail guard • Through the base electric • Unit Mounted Circuit Breaker • Powered convenience outlet • Frostat Performance Data -Packaged Gas/Electric Rooftop Units Tags RTU-6 Design Airflow(cfm) 5600 Cooling Entering Dry Bulb (F) 73.90 Cooling Entering Wet Bulb (F) 60.00 Ent Air Rel Humidity(%) 44.15 Ambient Temp (F) 83.00 Cooling Leaving Unit DB (F) 54.68 Cooling Leaving Unit WB (F) 50.96 Gross Total Capacity (MBh) 147.68 Gross Sensible Capacity(MBh) 126.62 Gross Latent Capacity (MBh) 21.06 Net Total Capacity (MBh) 140.24 Net Sensible Capacity(MBh) 119.18 Net Sensible Heat Ratio (Number) 0.85 Heating LAT (F) 33.41 Heating Temp Rise (F) 33.41 Output Htg Capacity(MBh) 203.00 Output Htg Capacity w/Fan (MBh) 210.44 Design ESP (in H2O) 0.500 Component SP Add (in H2O) 0.328 Field Supplied Drive Kit Required High Static Drive Kit Indoor Mtr. Operating Power(bhp) 2.36 Indoor RPM (rpm) 664 Indoor Motor Power(kW) 1.76 Outdoor Motor Power(kW) 1.15 Compressor Power(kW) 8.21 System Power(kW) 11.12 IPLV @ AHRI (IPLV) 14.2 MCA (A) 32.00 MOP (A) 40.00 Compressor 1 RLA(A) 12.80 Compressor 2 RLA (A) 7.10 Condenser Fan FLA (A) 1.60 FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 48 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Tags RTU-6 Evaporator Fan FLA (A) 4.80 Evaporator Face Area (sq ft) 26.00 Evaporator Face Velocity(ft/min) 215 Evaporator Fin Spacing (Per Foot) 180 Evaporator Rows ( ) 3 Min. Unit Operating Weight (Ib) 1958.0 Max Unit Operating Weight (Ib) 2360.0 Fan Motor Heat (MBh) 7.44 Evap Coil Leav Air Temp (DB) (F) 52.96 Evap Coil Leav Air Temp (WB) (F) 50.20 Dew Point Temp (F) 47.94 Rated capacity (AHRI) (MBh) 140.00 Exhaust fan power(kW) 0.56 Refrig charge(HFC-410A) -ckt 1 (Ib) 9.0 Refrig charge (HFC-410A) -ckt 2 (Ib) 5.8 ASHRAE 90.1 Yes Saturated Suction Temp Circuit 1 (F) 45.69 Saturated Discharge Temp Circuit 1 (F) 104.30 Saturated Suction Temp Circuit 2 (F) 45.72 Saturated Discharge Temp Circuit 2 (F) 103.83 IEER Rating () 14.20 EER @ AHRI Conditions (EER) 12.1 Total Static Pressure(in H2O) 0.828 FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 49 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Mechanical Specifications - Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-6 General The units shall be dedicated downflow or horizontal airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with AHRI testing procedures.All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation and control sequence, before leaving the factory.Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 1995/C 22.2, 236-05 3rd Edition. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 8117. Cabinet construction shall allow for all maintenance on one side of the unit. In order to ensure a water and air tight seal, service panels shall have lifting handles and no more than three screws to remove.All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2 inch, 1 pound density foil-faced, fire-resistant, permanent, odorless, glass fiber material. The base of the downflow unit shall be insulated with 1/2 inch, 1 pound density foil-faced, closed-cell material. The downflow unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 11/8 inch high supply/return openings to provide an added water integrity precaution, if the condensate drain backs up.The base of the unit shall have provisions for forklift and crane lifting. Unit Top The top cover shall be one piece, or where seams exist, double hemmed and gasket sealed to prevent water leakage. Filters Two inch standard filters shall be factory supplied on all units. Optional two inch pleated media filters shall be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Internal overloads shall be provided with the scroll compressors. All models shall have crankcase heaters, phase monitors and low and high pressure control as standard. Crankcase Heaters These band heaters provide improved compressor reliability by warming the oil to prevent migration during off-cycles or low ambient conditions. These are standard on all Voyager models. Refrigerant Circuits Each refrigerant circuit shall have independent fixed orifice or thermostatic expansion devices, service pressure ports, and refrigerant line filter driers factory installed as standard. An area shall be provided for replacement suction line driers. Evaporator and Condenser Coils Microchannel coils will be burst tested by the manufacturer. Internally finned, 5/16 , copper tubes mechanically bonded to a configured aluminum plate fin shall be standard for evaporator coils. Microchannel condenser coils shall be standard on all units. Coils shall be leak tested to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 225 psig and pressure tested to 450 psig. Sloped condensate drain pans are standard. Gas Heating Section The heating section shall have a drum and tube heat exchanger design using corrosion resistant steel components. A forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system. In order to provide reliable operation, a negative pressure gas valve shall be used on standard furnaces and a pressure switch on furnaces with modulating heat that requires blower operation to initiate gas flow. On an initial call for heat, the FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 50 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 combustion blower shall purge the heat exchanger 45 seconds before ignition. After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat. Units shall be suitable for use with natural gas or propane (field installed kit) and shall also comply with California requirements for low NOx emissions. The 121/2-25 tons shall have two stage heating (Gas/Electric Only). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor(s) shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. Units with standard motors shall have an adjustable idler-arm assembly for quick-adjustment of fan belts and motor sheaves. All motors shall be thermally protected. Oversized motors shall be available for high static application. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Multi-Speed Indoor Fan System Multi-speed indoor fan system is designed for use in applications for meeting the minimum requirement of CA Title 24. This system incorporates a multi-speed fan control to change the speed of the fan to 67% of full airflow based off of compressor stages. Variable Frequency Drive Variable Frequency Drives are factory installed and tested to provide supply fan motor speed Modulation.VFDs on the supply fan, as compared to inlet guide vanes or discharge dampers, are quieter, more efficient, and are eligible for utility rebates. All VFDs are designed to allow bypass if required. Bypass control will simply provide full nominal airflow in the event of drive failure. Bypass mode is indicated in the unit wiring manual. Modulating gas heat models with SZVAV allow tighter space temperature control with less temperature swing. Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. ReliaTel controls shall be provided for all 24 volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. High Pressure Cutout This option is offered for units that do not have High Pressure cutout as standard. Economizer- Downflow The assembly includes fully modulating 0-100 percent motor and dampers, barometric relief, minimum position setting, preset linkage, wiring harness with plug, fixed dry bulb and spring return actuator. The barometric relief damper shall be standard with the downflow economizer and shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment"off'cycle. Solid state enthalpy and differential enthalpy control shall be field-installed. Discharge Line Thermostat A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system. This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Discharge line thermostat is wired in series with high pressure control.When the discharge temperature rises above the protection limit, the bi-metal disc in the thermostat switches to the off position. opening the 24 VAC circuit. When the temperature on the discharge line cools down, the bi-metal disc closes the contactor circuit, providing power to the compressor. When the thermostat opens the fourth time, the ReliaTel control must be manually reset to resume operation on that stage. FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 51 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Stainless Steel Heat Exchanger Gas heat exchanger shall be of drum and tube design constructed from a minimum 304 Grade stainless steel. The stainless steel heat exchanger shall have a 10-year warranty as standard (Gas/ Electric Only). Tool-less Hail Guards Tool-less, hail protection quality coil guards are available for condenser coil protection. Through the Base Electrical with Circuit Breaker This option is a thermal magnetic, molded case, HACR Circuit Breaker with provisions for through the base electrical connections. The circuit breaker will be installed in a water tight enclosure in the unit with access through a swinging door. Factory wiring will be provided from the switch to the unit high voltage terminal block. The circuit breaker will provide overcurrent protection, be sized per NEC and UL guidelines, and be agency recognized by UL/CSA. Through the Base Electrical with Disconnect Switch Three-pole, molded case, disconnect switch with provisions for through the base electrical connections are available. The disconnect switch will be installed in the unit in a water tight RT-PRCO28-EN 121 enclosure with access through a swinging door. Factory wiring will be provided from the switch to the unit high voltage terminal block.The switch will be UL/CSA agency recognized. Note: The disconnect switch will be sized per NEC and UL guidelines but will not be used in place of unit overcurrent protection. Hinged Access Doors Sheet metal hinges are available on the Filter/Evaporator Access Door and the Compressor/Control Access Door. This option is available on all downflow models. Two-Inch Pleated Filters Two inch pleated media filters shall be available on all models. Powered or Unpowered Convenience Outlet This option is a GFCI, 120v/15amp, 2 plug, convenience outlet, either powered or unpowered. When the convenience outlet is powered, a service receptacle disconnect will be available. The convenience outlet is powered from the line side of the disconnect or circuit breaker, and therefore will not be affected by the position of the disconnect or circuit breaker. This option can only be ordered when the Through the Base Electrical with either the Disconnect Switch, or Circuit Breaker, option is ordered. This option is available on all downflow models (Gas/Electric Only). Defrost Controls Adaptive demand defrost shall be provided to permit defrost wherever coil icing conditions begin to significantly reduce unit capacity. Hinged Access Doors - Ultra High Sheet metal hinges are available on the Filter/Evaporator Access Door and the Compressor/Control Access Door. This option is available on all downflow models. FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 52 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Unit Dimensions - Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-6 NOTES: 1.GAS CONNECTION PIPE SIZE 112" 2.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS.(SELECTED OPTION:SEE ACCESSORY SHEET) 3.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 54" • 0 0 1" DOWN FLOW CONDENSATE 4444444%', DRAIN CONN 1"NPT 6411/18" GAS CONNECTION(SEE NOTE 1) 121 11!16" 33 3/16" 15/16" (UNIT DIA.HOLE AY/ 1 (UN CONTROL WIRE) 84 3H6" 211/16" 3"DIA HOLE (UNIT POWER WIRE) PACKAGED GAS/ELECTRIC-DOWNFLOW ISOMETRIC DRAWING 4 1/4" — ._-1915/16" —28 3/4" oc 26 7/16"--c— 41/4"J km:gyp SUPPLY RETURN 6811/16" 76 5/16" NEI T4;x1111 PACKAGED GAS/ELECTRIC-DOWNFLOW PLAN VIEW DRAWING FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 53 of 59 Installed by Others Whole Foods Tigard OR January 22.2014 Unit Dimensions -Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-6 ELECTRICAL / GENERAL DATA GENERAL PERFORMANCE Standard Motor (11131141 Model(Ton): (1O)(11k121113N141 'YHD150F(12.5) Minimum Circuit Ampacity: '32.0 Unit Operating Voltage Range: '414-506 Maximum Fuse Size. 40.0 Unit Primary Voltage: 460 Maximum(HACR)Circuit Breaker 40.0 Unit Secondary Voltage: s1 NI 61 k) Unit Hertz: 60 Standard Oversized Motor Accessory Oversized Motor Unit Phase: 3 Minimum Circuit Ampacity: Minimum Circuit Ampacity: Maximum Fuse Size. Maximum Fuse Size: EER:(7) '12.1 Maximum(HACR)Circuit Breaker Maximum(HACR)Circuit Breaker GAS HEATING COMPRESSOR Heating Models: 'High Circuit#1/2 Heating and 1 Stage Input(Btu/hh) 250,000/175,000 Number '2 Heating and 1 Stage Output(Btu/h): 203,000/142,000 Horsepower 5.6/3.67 Min./Max.Gas Input- Phase: 3 Pressure Natural or LP(in w.c): 2.5/14.0 Rated Load Amps: 12.8/7.1 Gas Connection Pipe Size: 1/2" Locked Rotor Amps: 100.0/46.0 INDOOR MOTOR Standard Motor Standard Oversized Motor (6) Accessory Oversized Motor X61 - Number '1 Number Number Horsepower 3.0 Horsepower Horsepower Motor Speed(RPM): 1740 Motor Speed(RPM): Motor Speed(RPM): Phase: 3 Phase: Phase: _ Full Load Amps: 4.8 Full Load Amps: Full Load Amps: Locked Rotor Amps: 40.5 Locked Rotor Amps: Locked Rotor Amps: OUTDOOR MOTOR POWER EXHAUST COMBUSTION BLOWER (Field Installed Power Exhaust) MOTOR Number (8) '2 Horsepower 'N/A (Gas-Fired Heating only) Horsepower 0.5 Motor Speed(RPM): N/A Phase: N/A Horsepower '0.05 Phase speed(RPM): 1,10D Motor Speed(RPM): 3500/2800 Phase: 1 Full Load Amps: N/A Locked Rotor Amps: N/A Phase: 1 Full Load Amps: 1.6 Full Load Amps: 1 Locked Rotor Amps: 3.8 Locked Rotor Amps: 0,78 FILTER REFRIGERANT Circuit#1/2 Type: Throwaway Type: 121 'R-410 Furnished: Yes Factory Charge Number 414 Circuit#1/2: 9.7 lb/6.2 lb Recommended Size: 20"x20"x2"/20"x25"x2" NOTES: 1. Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value does not include Heater. 5. Value include Standard Motor. 6. Value include Oversized Motor 7. EER is rated at AHRI conditions and in accordance with DOE test procedures. 8. For Compressor Motors and Condenser Fan Motors:Amp draw for each motor,multiply value by number of motors to determine total amps. - 9. HP for each compressor. 10.TXV/Face-Split Option(Downflow Only)YCD211E3,4,W(EER):12;(System Power kW( 17.33;(Refrigerant Control):Expansion Valve: 11.TXV/Face-Split Option(Downflow Only)YCD241E3,4,W(EER):11;(System Power kW).22;(Refrigerant Control):Expansion Valve: 12.TXV/Face-Split Option(Downflow Only)YCD301E3,4,W(EER):11:(System Power kW(25.45;(Refrigerant Control):Expansion Valve; 13.Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270 or 370. 14.AFUE is rated in accordance with DOE test procedures. FLD=Furnished by Trane U.S. Inc.dba Trane/ Equipment Submittal Page 54 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Weight,Clearance& Rigging Diagram -Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-6 \-l . CLEARANCE 68" . —\7 (1727.2mm) ,,,,, ,, _,_,,.,,, __ __ ...i.ii____.N‘z..„_______,_,,..), .„.. CLEARANCE 36" CLEARANCE FROM THE (914.4mm) TOP OF UNIT 72" (1828.8mm) e r r ,._ s , v " CLEARANCE CE 80" o " r CLEARANCE 48" (1219.2mm) a DOWNFLOW-PACKAGED GAS/ELECTRIC CLEARANCE UNIT OUTLINE ■ ROOF OPENING ■ 761/2" .-61" i DOWNFLOW-PACKAGED GAS/ELECTRIC ROOF OPENING CLEARANCE FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 55 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Weight, Clearance& Rigging Diagram -Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-6 INSTALLED OPTIONS NET WEIGHT DATA Accessory Accessory Economizer 80.0 lb Motorized Outside Air Damper n Manual Outside air Damper '(}J Oversized Motor �� High Static Drive flll�r'�//i,•�a\1�t Thru the Base Electrical 23.0 lb \` �� Unit Mounted Circuit Breaker 10.0 lb Unit Mounted Disconnect ,„,%------ Power Exhaust IIII��/b:111;)��� Hinged Doors 27.0 lb ����" " Zone Sensor LPG Conversion Kit e — — — Powered Convenience Outlet 38.0 lb Roof Cub CORNER WEIGHT BASE UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITY SHIPPING NET O © © O E F 12610.0 lb 2126.OIb 676.OIb 555.OIb 406.OIb 487.Olb 56" 36" NOTE: " 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2.TO ESTIMATE SHIPPING WEIGHT OF OPTION/ACCESSORIES ADD 5 LBS TO NET WEIGHT. 3.NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE<5 LBS. 5.WEIGHT ARE OF BASE UNIT ONLY FOR TOTAL WEIGHT,10 DIGIT FACTORY INSTALLED OPTION(ECONOMIZER AND/OR OVERSIZED MOTOR OR FIOP/ACCESSORY WEIGHT MUST BE ADDED. ,, 44 114r%. -. ji % ■ E , I F :Ili RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 56 of 59 Installed by Others Whole Foods TI!ard Olt wehohtClearance Rigging Dia gram 9ran _P a cka9ed Gas/Electric Rooftop Units Jana 22,2014 Item: Qty:/ Tag s 1-----, 1 1�r I I " 1 i c l , / • THROUGH THE 8E ELECT R/CAI nHRaU1icTMe BASE AGCEesORY_p�N v,EyyFLEC?Iq,CAI /". /iii....................................................... tNROU,y� �THROUGH THE BASE EI Ecr E 8 R, ACCESSORY,PLAN 14614, ,CAI R OOF CURB FGD ,c /x Geoe Trane/ instal/et i by Others Equipment Submittal Page 57 of 59 Whole Foods Tigard OR January 22,2014 Accessory - Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-6 N W zz °a0a 0 U z w Z(fl)U teti CO cL I o -- to ' U cc 11 co to U co) � Q 1 � r m 2WZ OVQa gg W Lv S g U fn_Q h � W 6za zwit; 9.< FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 58 of 59 Installed by Others Whole Foods Tigard OR January 22,2014 Accessory -Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-6 PAii %tktifi ceN tifi'���11�� %f‘o 2 0 z 0 U w 0 co U) orn U U O J z 0 a 0) Ui w U a. O W O O S W N_ 2 0 2 0 U W FLD=Furnished by Trane U.S.Inc.dba Trane/ Equipment Submittal Page 59 of 59 Installed by Others