Loading...
Report INSTALLATION INSTRUCTIONS CertainTeed SAINT-GOBAIN PRO ,,,E Shingles Read Before You Start Application Fastening — IMPORTANT Steep Slope(greater than 21:12): To obtain stated area coverage and to achieve designed performance, `+ Use SIX nails and FOUR spots of asphalt roofing Shingle - `�_-*--- these directions must be followed, including 5-5/8"(143 mm) ° ./ 1--'. cement"for every full Landmark PRO shingle,located exposure to weather cool Deck at , j , as shown below(within illustrated shaded areas). N1- Notes:Fasteners must be placed between the lower Proper 2.'o0ke3 Under-Driven Over-Driven 2 nail lines. Landmark PRO shingles conform to: Naemg ASTM D3462 For decks 3/4"(19 mm)thick,or thicker,nails must go SLOPE 12" 14-3/4" 12" ASTM 03018 Type �f(305 mm)� (375 mm)- —(305 mm)H at least 3/4"(19 mm)into the deck.On thinner decks, NAILING ASTM E108 ClassA Fire Resistance nails must go at least 1/8'(3.2 mm)through the AREA I tKaweer�f ASTM D3161 Class F Wind Resistance an■lip deck.Nails must be 11 or 12 gauge roofing nails, (r�.�;��� UL 997 Wind Resistance corrosion-resistant,with at least 3/8"(9.5 mm)heads, *4Vsarsa• UL 2390/ASTM D6381 Class H Wind Resistance and at least 1"(25 mm)long. t ■®■� ASTM D7158 Class H Wind Resistance f } } } NYC-MEA-120-79M IMPORTANT:NAILS MUST BE LOCATED WITHIN Roofing Cement CSA Standard A123.5-98(&-05) THE FACTORY-APPLIED NAIL LINES,TARGETING Nailing areas for steep slopes(greater than 2112) Ontario BMEC Authorization#97-10-219 SHADED AREAS SHOWN BELOW.SHADING and"Storm inesia Nail between lo and 2 nail lines as shown above. (BMEC report available upon request) IS SHOWN ON ILLUSTRATIONS ONLY,NOT THE FINISHED PRODUCT Apply FOUR 1"(25 mm)diameter spots of asphalt roofing cement beneath shingle as shown above. G90 Low and Standard Slope(2:12 to 21:12): Asphalt roofing cement meeting ASTM D4586 Type II Gm'(2912) Use FOUR nails for every full Landmark PRO shingle, is suggested. Ikrilir located within illustrated shaded areas as shown below. Storm Nailing(all slopes):If weather conditions are such that sealing of shingles may not occur prior to Position nails vertically between the upper and lower nailing-guide lines.For low and standard slopes,it is a significant windstorm,then it is recommended that the pip ana, acceptable to nail between either the middle and lower shingles be attached using the"Steep Slope"nailing (at2 wk�2tH2) lines or between the upper and middle lines. instructions above. ""°` **CAUTION:Excessive use of roofing cement can G Tas' (272) wuuxG IT 1t Y4" 12. Mbt )f(305 mm)+ (375 mm)—m—f(305 mm) + -.1 cause shingles to blister. L a.S' (2112) /(Naig Limb i'(25 mm) ,_-_,, r(25 mm)� f Slope Restrictions The roof deck must be at least:3/8"(9.5 mm)thick plywood, °°ralw`".:andsln°aline.“ (ean2]vee2„n ( ) PY wgaaw..krreeeewwrem�e or 7116”(11 mm)thick non-veneer,or 1"(25 mm)thick nominal wood deck For UL fire rating underlayment may be required.Apply flat and Roofing Over an EXISTING Roof (Roof-Over) unwrinkled. Cut old shingles back flush to rakes and eaves. 1st Course:Cut 2"(50 mm)off the bottom of the Standard or Steep Slopes:CertainTeed recommends Apply drip edge along rakes and eaves,if desired. full Landmark PRO shingles and apply remaining DiamondDeckru Synthetic Underlayment,Roofers'Select 11-114'x 38-3/4"(286 mm x 984 mm)pieces.For all High-Performance Underlayment,or shingle underlayment meeting The°5 Course Diagonal Nesting°method of ASTM D226,D4869 or D6757.Always ensure sufficient deck application described below is suggested for roofing courses,align top edge of shingle to be applied ventilation,and take particular care when DiamondDeck or other over square-tab asphalt roofing shingles of 5-5/8" with bottom edge of old shingle in next course. synthetic underlayment is installed.Follow manufacturer's application +/-1/8"(143 mm+1-3.2 mm)exposure. 2nd Course:Cut 6"(152 mm)off the left end of a instructions. Starter Course:The starter course consists of full shingle and apply remaining 32-3/4'(832 mm) Low Slopes:One layer of CertainTeed's WinterGuardTm 5-5/8"x 38-3/4'(143 mm x 984 mm)strips formed piece.Exposure of 1st course only is reduced to Waterproofing Shingle Underlayment(or equivalent,meeting ASTM by cutting off the top 2'(50 mm)of CertainTeed's 3-5/8"(92 mm). D1970)or two layers of 36"(914 mm)wide felt shingle underlayment Swiftstart self-sealing shingles,or equivalent. 3rd,4th,5th and Succeeding Courses: (Roofers'Select or underlayment product meeting ASTM D226, Cut 6"(152 mm)off the left end of the first starter Apply as described above in"5-Course Diagonal D4869 or D6757)lapped 19"(483 mm)must be applied over the shingle only.Apply the remaining 32-3/4'(832 mm) Application Method"section. entire roof;ensure sufficient deck ventilation.When DiamondDeck piece to the lower left corner of the roof,overhanging or other synthetic underlayment is installed,weather-lap at least the rakes and the eaves 1/2"(13 mm)if drip edge is 20"(500 mm)and ensure sufficient deck ventilation.Follow used,or 3/4"(19 mm)if no drip edge is used. sd' se • manufacturer's application instructions. Continue with full lengths along eaves. ` Cold Weather Climates(All Slopes): �'"y- a ,r.• • e Roof,"_ IMPORTANT:When the first course shingles IA'•'?zs 7 Application of WinterGuard or its equivalent is strongly recommended are applied,ensure that the end joints of the starter �, whenever there is a possibility of ice build-up.Follow manufacturer's shingles and the first course shingles are NEVER '4,�z7y0,/'OSm\ �"cor�rse`;- application instructions. LESS THAN 3-1/2'(90 mm)apart.Either plan the "� 411110, j,, z Flashing:Corrosion-resistant flashing must be used to help prevent ealw �- n' •starter shingles'application to avoid end joints getting •�'Mi leaks where a roof meets a wall,another roof,a chimney or other closer than 3-1/2"(90 mm)or cut back the affected objects that penetrate a roof. first course shingle to ensure the minimum ////////// S u'se ' Sealing:Shingle sealing may be delayed if shingles are applied in 3-1/2"(90 mm)end joint spacing. (7`3 (i s cool weather and may be further delayed by airborne dust .."`,•c�_e accumulation.If any shingles have not sealed after a reasonable time ,, period,hand sealing may be necessary. CAUTION:To prevent cracking,shingles must be sufficiently warm to allow proper forming for hips,ridges and valleys. INSTALLATION INSTRUCTIONS CertainTeed '�� 1,....(2. SAINT-GOBAIN PRO Shingles 5 Course Diagonal Application Metal Shp Flashing ld Method {6" (152 mm) and 11" (279)} F w �_ (NEW Roof or Tear-Off) room.) 1 7518"(194 mm) Underlayment:Apply as Mnimum {{r777///FFFiih��FFF Minimum y App y required,following manufacturer's instructions. Diagram'A"illustrates application of Roofers'Select and standard felt ::�� a ps mm)MMl h11 underlayment,for standard or steep-slopes only.Always ensure sufficient ��I�� �—��_ deck ventilation,and take particular care when DiamondDeck or other _r_ Fasten Amens ����=%��1, synthetic underiayment is installed.Follow manufacturer's application ,� ���i/_�j_ 02�.i��7. instructions. Comex n s 1 �' 4.4�Ii~�:�����- .g;�-I�•• i . War ==%AID /Iii -I41ir__ it Alignment:Snap horizontal and vertical chalklines to assure shingles . �rApi Iiii�L1'''���/S/ will be correctly aligned.Expose all shingles 5-5/8"(143 mm). z /� �j Iii I�. ���——�� �I�- II/� III •II ��` 1 tea Course:Use applicable CertainTeed Starter"^product,such as �. §�+��O0.1 �rj ��I� ��I� ��fjj SwiftstartTM,with a minimum height of 7-5/8'(194 mm)or its equivalent. `�.� .I4�=4I**14,AA���j..=li•I��:• Apply with sealant at eaves edge.Cut 6"(152 mm)off the left end I�ArIij,4I���- g y Apply the remaining piece to the Shamdw Ridge Crest.cs .���eillg�� •� •i +rr�'—"Mee, of the first starter shingle only. lower left corner of the roof.Use full length starter shingles for Ridge-shogI./da kke�w .4..i;�4`�,�� 1 rest of the course.(See Q). - r IA���.4 \`""' :l.. IMPORTANT:When first course shingles are applied, ` `a I ensure that the end joints of the starter shingles and ^``t` `.�,,♦♦-�/�♦ ����1� use the first course shingles are NEVER LESS THAN �`*II_— ♦'•`♦♦'+�,�;'Or- • ♦ ∎ i �y'nenr 3-1/2"(90 mm)apart.Either plan the starter ,.,;;�♦\.;♦♦♦;:�♦\.:;��=;::�♦:=A�:� shingles'application to avoid end joints getting ;;r:-;.♦-♦:,,:�.♦♦♦: =♦♦♦;.;♦♦l','y:�4r`' closer than 3-1/7(90 mm)or cut back the ♦ ♦♦ affected first-course shingle to ensure the �.V,,♦:♦♦♦♦♦♦♦♦♦♦;:,�: 1∎♦�4♦♦♦♦♦♦:,�;: 1♦+��, minimum 3-112"(90 mm)end joint spacing. 31�+rl ♦�,♦♦',,♦..♦♦♦$Ilt■ F �• 0♦ Thmuosk Meier Mac in the wmw end a skier ♦ p,l /POW , , ii. inm00r0f failure ♦♦:'���►� Q111. Starter shingle pememefaWeorsron�rs.oadeck ' mo+emenuaeienoraf t and formation of ���♦♦� ' it if- Ice demo from Shingle damage a failure \ i R e m o v et1 these p,io r t i o n s i resulting kam Yndepyr ventilation re s d I sl , covered byGNinTeeda Limited Shingle .. Wan0M'Ca ireelra only.fa further 1 �hend ehny. IMPORTANT:Do not align end joints of shingles wlomwaon about e1acwnWetioo.pease r,bp 0^. '4 -—µn i.e.. rash the"crlenTesd Shingle closer than 3.1/7(90 mm)from one another. Applicators Lemur(w 1800404985 la a copy).0050 The Principles of Attic 1 1st Course:(SeeO).Apply a full Landmark PRO hnolwm'eahurolwii+ + ,w " Wavle s0�r(somm) shingle at the lower left corner of the roof,flush with ae copy). sy c� /j�� yep dmofng cement oi the starter course. N� �� cade �NI ti♦�— Cut off 7(50 mm) 2nd Course:(SeeO).Cut 6"(152 mm)off the left end ��A� /�♦♦, i m.ve. of a full shingle and apply remaining 32-3/4"(832 mm)piece '.�'♦Ir�.� over left edge of 1st course. ` '♦♦. '`�1'.\ 3rd Course:Cut 11"(279 mm)off the left end of a full ♦ � S shingle and apply remaining 27-3/4"(705 mm)piece over left ,, At' 275, edge of 2nd course. \ yC4 4th Course:Apply the 11"(279 mm)piece over left edge wMe of 3rd course. wood rxy,,,a"`S`dis1P ,--O• f, 5th Course:Apply the 6"(152 mm)piece over left edge of 4th course. ,----• e„p `∎ Apply a full shingle against the right edge of each shingle in courses 1 ♦ r """e, ��� through 5.(See m). Im roa+ •�s '■`,, Succeeding Courses:Beginning with a full shingle,repeat the 5-course \\ � ��t diagonal pattern up left rake(See( ).Apply one full shingle against each -,`� . ♦♦\� Eer shingle in courses 1 through 10(right side of sectionseand(s). 11P '7 �f .. , Proceed up the rake in 5-course sections and fill in diagonally with full �"nw' \ ♦ shingles,until the roof is covered.Diagonal application is important to 51_e q•a� ` o++ :'W.- assure proper finished appearance. p,s^ ,,ra°�.et ALTERNATE METHOD:An approved alternate method of �40.00 u �� application is the 5-5/8"(143 mm)and 11-1/4"(286 mm)method. New for CertainTeed 2012 For the past 10 years, NailTrak- has enabled installers to shingle with improved speed ' L4" )'I'1L'11?1( PRO and accuracy. With a nailing area that's three times WIDER than typical laminate Architect 80 shingles, nails hit home with NailTrak. A feature on all Landmark Series shingles. Speed and accuracy result in lower labor costs. Designer Shingles No leaks. No de-lamination. No callbacks. The cost of doing business has gone down with NailTrak. • ,14ailTra .. pz �• +,20.taskks,$,4,4.1 4r`M7 -,."+• '"!,•e,4iE•l,lA:w0:-4:. ' \ � _,_ — _ -- s :, •• g441 • l� Rol. - ,. 1-1/2" Typical 8 W _ ‘ r'0 - , • . Nailing Nailing • ' - '� iy _ _T _ _ _--- _. - - — , _ :� Area Area • . `_ — — _ - = ..s w'+ml,srr e.► "'w�►w' 4R♦Rf• `1i}i".:*46..:if....'f`piww3 „61.0 a: s 11M1 111111i: 11 ! 1 n {ti UNDERSIDE -.,...a, -.- FRONT BACK OF TOP �t.w�q h . _ i r£ Wide nailing area for increased Sealant placed low to avoid Specially formulated Quadra-Bond "`" speed and accuracy. gumming up nail guns. adhesive adheres the two-piece ...—..,,,c ,.,,, --, . ---...,,.*r--.,. "-- =d �-' laminate shingle. '"1 ,.., :7„,\T\ s` 1 �` '"I 4 1111111 r7, ENERGY STAR Landmark Pro e _ Architect 80 Iror -.- - .�"'f3r AWARD 2011 illy T "available in AS a 2011 ENERGY STAR areas shown '!�`���#, — •°"`°"'t SUSTAINED EXCELLENCE f �' Sustained Excellence jw�i11001 - recipient for Energy Management, we are proud ��7��/�� Z of our commitment to designing high quality, T�� sustainable roofing products. `' ... •' - Shown ...x Def Weat d ood -R. Li----,-) .,7 i -ASK ABOUT ALL OF OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: CertainTeed Corporation C `� P.O. Box 860 ((3/3 -•�5U air ,rti C^./ Rci ROOFING • SIDING • TRIM • DECKING • RAILING • FENCE • FOUNDATIONS Valley Forge, PA 19482 GYPSUM • CEILINGS • INSULATION • PIPE Professional: 800-233-8990 erta i nTeed www.certainteed.com http://blog.certainteed.com Consumer:800-782-8777 ©12/11 CertainTeed Corporation,Printed in U.S.A. SAINT GOBAIN Code No.20-20-3286 1 SAINT GOBAIN Landmark Pro Architect 80 is designed specifically for the professional roofing contractor that takes pride in providing more to their customer. Landmark Pro Architect 80 improves upon the CertainTeed Landmark shingle, a leading -. consumer publication's "Best Buy" for the past five ears. -1-',. t ! `• � i We started by adding more weathering asphalt to the industry's toughest fiberglass mat , E , ,. to provide more protection. Then we incorporated our Maximum Definition color blend technology to give the product more vibrancy on the roof. Included is the proven performance of our NailTrak feature, enabling faster installation. x Landmark Pro Architect 80 offers the industry's strongest warranty. Protecting your •,yr .k, ,4 , reputation and safeguarding homeowners from manufacturing and aesthetic defects. j Landmark Pro Architect 80 Standard Warranty Sri,:ar letrF ` 3 -fr Sunrise Cedar -, Max Def Resawn Shake • Lifetime Limited Warranty • 10-years of SureStart protection • 15-year 110 MPH wind warranty (Upgrade to 130 MPH available) (CertainTeed starter and CertainTeed hip and ridge required) • 1 5-year algae resistance warranty Add it all up and what you get is the opportunity to offer a lot of additional value for the money... and today that means more than ever... i Max Def Weathered Wood Max Def Georgetown Gray Mountain Timber Max Def Heather Blend :__i1 ') iii „ 11 1311 I�� � i�� 1i;.l', X114 ax De aa7ta1=tR •t, oOd ' r a. 'n Weat good -r Landmark Pro Architect 80 specifications: Landmark specifications: Pacific slue (Available only in Hawaii) Max Def Hunter Green Max Def Burnt Sienna Max Def Moire Black • 270 lbs/square • 240 lbs/square • Premium Max Def color palette • Traditional color palette • NailTrak'" for faster installation • NailTrak'" for faster installation Landmark Pro Architect 80 Silver Birch is an ENERGY STAR rated product and may qualiy • Lifetime limited warranty • Lifetime limited warranty for a federal tax credit. • 10-year SureStart protection includes: • 10-year SureStart protection includes: - Materials, labor, tear off and disposal cost - Materials and labor costs • 15-year algae resistance • 10-year algae resistance Look deeper. With Max Def, a new dimension is added to shingles with a richer mixture of • 15-year 110 MPH wind warranty with • 15-year 110 MPH wind warranty with surface granules. You get a brighter, more vibrant, more dramatic appearance and depth upgrade to 130 MPH available upgrade to 130 MPH available of color. And the natural beauty of your roof shines through.