Loading...
Permit CITY OF TIGARD MECHANICAL PERMIT 1111 _ • COMMUNITY DEVELOPMENT Permit#: MEC2014-00391 Date Issued: 07/31/2014 TIGARD 13125 SW Hall Blvd Tigard OR 97223 503 718 2439 Parcel: 251 12ACO2600 Jurisdiction: Tigard Site address: 7320 SW BONITA RD Project: EMPIRE BATTERY Subdivision: 2000-084 PARTITION PLAT Lot: 1 Project Description: Replacing existing gas pack adjacent to the office. Contractor: COLUMBIA HEATING&COOLING INC Owner: EMPIRE BATTERIES. INC PO BOX 230397 PO BOX 23962 TIGARD, OR 97281 TIGARD, OR 97281 PHONE: 503-624-2704 PHONE: FAX: 503-598-0270 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 07/31/2014 $252 17 Class of Work: OTR Type of Const: VB Plan Review 07/31/2014 $63 04 Occupancy Grp: 5-1 Occupancy Load: 12%State Surcharge-Mechanical 07/31/2014 $3026 Stories: 1 Info Process/Archiving-Sm$0.50(up to 07/31/2014 $1 50 11x17) Project Valuation: $6,600.00 Fuel Air Handlers Fuel Types. Natural Gas Units< 10000 cfm• Gas Pressure: Units> 10000 cfm. Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP'. Floor Furnaces. 15-30 HP. Unit Heaters' 30-50 HP Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total S346.97 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc Duct Work: Fire/Smoke Dampers This permit is issued subject to the regulations contained in the Tigard Municipal Code, Stale of OR Specialty Codes and all other applicable law. All work will be done in accordance with approved plans This permit will expire if work is not started within 180 days of issuance, or if_.wefk--is suspended for more the 180 days ATTENTION' Oregon law requires you to follow the rules adopted by the Oregon Utility Notion Centei-',\ Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090 You may obtain a copy of the rules or dire questions to OUNC y calling 503.232.1987 or 1.800.332.2344. IssId By: f n� Permiltee Signature: 1 Gr d L Call 503.639.4175 by 7:00 a.m.for the next available inspection date. \\\— This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application FOR OFFICE USE ONl.N• City of Tigard Received �7 IN p`,� [rare/By: Irl i1 gEM 0 ^/I • 13[25 SW Hall Blvd..'Tigard,OR 97 Plan Re Q 1, Other Permit: Phone: 503.7182439 Fax: 503.598. �Q�a r)sceiBy: ,ir. m TIC A RD Inspection Line: 503.639.4175 P% Date Ready- y: Iffli fil See Page 2 for Internet: www.tigard-or.gov O. P•• , . (ll�lethod: Supplemental information <' ' T 'PE OF WORK .., .\ti.Gols COMMERCIAL,SEE" SC lEI1L'LL-.t.SE CHEC'i(LIS`F. ❑New construction Addition,alterationi1ucemeni Mlechanical permit fees"are based on the value of the work t performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. , . Value:$ (04:' bb fl CATEGORY OF CONSTRUCTION ;: RESIDENTIAL EQLilPM IP1CISY$'T.E11 3FFF " S ❑ 1-and 2-family dwelling rtmercial/industrial ❑Accessory building For special information se checklist. ❑Multi-family ❑Master builder ❑Other: Description Qty. I Ea. Total JOB SITE INFORMATION AND LOCATION heating/cooling: --� 1i• �j �v irirconditi plait Job site address: -�'{/l (requdres site plan showing p4�ccmctti? 46.75 / ^ � �n Furnace 100.000 BTU(ducts/vents) 46.75 City/State/ZIP: ` L vJ 1 7 Z� Furnace 100,0001 BTU(dactslvents) 54.91 Suiteibldg./apt.no.: Project name: �l�� Heat pump (requires site plan shoeing placement) j 61.06 1 Cross street/directions to job site: '7( Duet work 1 23.32 • A lull Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 - Unit heaters(fuel-type,not electric). in-wall, in-duct,suspended.etc. 46.75 Subdivision: Lot no.: Flue/vent for any of above 23.32 Other: 23.32 Tax map/parcel no.: Other fuel appliances: DESCRIPTION OF--tt WORK ' Water heater 23.32 C � � !J 14-6, S Gas fireplace 33.39 Flue vent for water heater or gas Pmt- fireplace Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert _ 23.32 0 PROPERTY OWNE#2 ❑ TENANT Chimney/liner/flue/vent 23.32 Other: 23.32 Name: T,/ ,I.1 Environmental exhaust and yentiiatibtr. - Address: Range hood/other kitchen , equipment I 33.39 City/State/ZiP: Clothes dryer exhaust 33.39 Single-duct exhaust(bathrooms, ( ) Phone:( ) Fax: toilet compartments,utility rooms) 23.32 ® AF('LICANT - 0 CONTACT PERSOi. Attic crawlspaee fans 23.32 -- _.__. Other 23.32 Business name:Columbia Heating and Cooling,inc. piping!Fact i ---- Contact name:Marlena Meedom SI4.15 for first four;54.03 for each additional — - -- - - Address:PO Box 230397 Furnace,etc. Gas heat pump City/State/ZIP:97281 Wall/suspended/unit heater Phone:(503)624-2704 Fax: :(503)598-0270 Water heater Fireplace E-mail:columbhc uJteleport.com Range CONTRACTOR' Barbecue Business name:Columbia Heating and Cooling,Inc Clothes dryer(gas) , Other. Address:PO Box 230397 bitGllAlsl tCAl:t`EIt(►i1T,FS s4.. City/State/ZIP:Tigard,OR 97281 ; Subtotal .• P12e14f fc (44 i►•.5e, Phone:(593)624-2704 Fax:(503)598-0270 Plan review(25%ofpenmit fee) le,,24 CCB lie.:76359 State surcharge(12%ot•;permit fee) /04-O q t/� �f TOTAL PERMIT FEE 2 Zeo Authorized signature: _1i 3 Ji iaL k This permit application expires if a permit is not obtaineiewi 41{�t � days after it has been accepted as complete. Print name:Marietta R Meedom Date: ' Fee methodology set by Tr;-County Building tndustty Service Board uU..l:d:n..lbnrm De•A/Gf'_D.v.w:f An,.Any rwrn�na 11(14617T II rrn riwif+vl n', RECEIVED JUL 2 8 2014 CITY OF TIGARD PLANNING/ENGINEERING • CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: I OTC: I ` V A P 0 U`� permit#: 1/l�1LC 2CJ(fir-00 a7 1 14 j Address: `73 20 ALL) (ky T- Suite#: Date 7(.4 (A- -114 ii \ 5c rozE OFFICE CO PY r cRE pLJ E E?Y�5YI ry 6 EM Pti?E 13A-1" TEr �,4 5 p7A K r' 1 L 1T 73z° 5%,\I Bow ' YA or ma a RECEIVED JUL 282014 CITY C' TIGARD ? U41T EL[CTI(CAl UYlT,71 UNIT 131[0137 IN/133 1 _ «�7 jfif'�ERINC: !•� CN(7.CCT A13TIC3 Le Ni •l• ' f -� j-'` PIMP':11.4 Y UM 21-JN1A24(040/010110 200/23/•1-10 301 132.3 40-1/e' 1011 22.17/11 311.4 15-5/11 3M.! 13-11/10 746.3 -+ 1.13/q 21.1111-.. 1-IS/11�-• ..44131•/11430413400010)(3/5/0 20,270.1, 244/210-Ji0 331 140.0 12.1/6 Itl4 72•IlrH 721.1 17-3/11 313.E 15-131U 411.4_, C (232.11 1547.71 1.757.0 61E51-l11A31(014/010101510 211/230•1. 244/231-3-10 311 144.4 4{•1/4 7172 22.13/16 313.4 1S-Sn0 341.1 11-1/4 427. "JI 3•7114 NE$(•/l1A711aa0alw 410-3.11 •333 ISO.! 41-l13_ 1172 22.1311{ 371.4 15-5/7{ 311.1 11-514,422.3 a (11.37 y�y ill- 1Ir CORNEA 1E10YT 11/36 `,�, 11113 VOLTAGE- REQUIRED CLEARANCES TO OOMBUSTELE MAIL (y 2.711 RETURN * SUPPLY •1' •2' ')' •4• (04441(117 (13.11 © 61Lf1.111 A24f 010/113IJ4 203/231 45.1 23.1 10.127.111.1 41.4101. 411.3 r@ 00 UNIT 11 IA3.31 N CSI-(11 434 1 0/1Ja01f!1510 200/27/44.3 27.1 11.0 21.0 12.4 42.1 IU. II.l DKI SIDF OF M]T 2[50.11 7"'I z *----=' 61CS(•l31A701 R1JIa1(3I510 213331(1.42,.7 U.e 21.117.113.4111. 30.1 SIDE 0►1'OSITE OKTS 11 1175.0 O 1•;` +, r wrigl OF 11(1 0 IO.EI ~aTIOYAII. t-OPTIONAL ISM-/uA311161/110110 411 41.427.113.421.1,14.141.3_116. 12.1 ELK PAWL R(TIIRY I ��� 131 APlf !t 1111.11 13.15/16 I AIR '- NEC.REQUIRED CLEARANCES [ CA 40.47 .1 OPENING • [4[111 I IKME7 1*1 E �- `, NOTE: ALL TABLE DATA IELEYA41 FOR ALL.FACTOI7 3111411(0 i I 11111[3 UNIT( MCI EMT SIZE 7 I1I/. ,. I OPTIONS INCEPT ECONCOUIEA 42 HOMO)14.01 1 f IjDE 34(171.01 ____ {I ',$"9"°) III" i UN11 130 ROCK ON COOCRIEE SILLS OM 011(1 '•.� �j __--• 7-1(11 (ROUNDED 311110413.Pp[A 04731 SIDE........... 42 11010.3] 0410001 COIL �. /.) ► gt.07 ...•... !w `- ---- REQUIRED CLEARANCE FOR OPERATION AND SERVICING 111 .3. SCES 1117 CA r �_- ., __ --*-""'fir -•2 [SU.COIL ACCESS]I00 14(114.11 . ` - ((KEPT FOR NEC 3EOtlI1[KRTS7 42[7010.1] 1 O \-OUTD0011 I UNIT TOP 44 11211.21 © DICT P111(1 [OKIi 12(111.0]-3 DUCT PANEL 12 004.374 A 100011(CIL 1132.11 •4141114 DISTANCES:IF UNIT 13 KACEO LE1i 11341 It I3114111 13011 WALL VI 4 TOP YEE toll 171214.11111]73143 4(11011111(0 NINE 0CICKIN(SE1. at * 110411101$11 Il ARE IN 11 fl-7/11 110.3] 1 - 47 •+ .4-4-1/2 123.41 1 (1113.01 1114.31 -T J4. 421.37 OIR.I.D. JJIIIIIIHID1- I„I -7.1ii • IA.R LE III'IIII'�IIIII III . , ••-r 1 - - l/a• 422.21 PIA.HOLE C04TIOL(3131 •A• r 1-114 ' {lP}. 1 1123.31 I COT • • -1 .iii-�a 1fq 318/12 RETtlRI ll = . 1747 . I • I- • • 11-1311{ (11'.27 MIME 0/131130 rim )2,-----, .-\_! f!!?SI •I• [301.1)(13111 IL tll _ ! `Q lo-3n1 4254.43 I 1 • �_ 0-= ° s' o. nai; fe r 1 r 1 00i DRAIN 0311.17 C04431O]0 3/4•(11.01 3.7.1. -+• 12-13/14 f- 1(341 \....7 I-13114 Ir2'112.7111.1.1, 1 1/1.122.11 PEEP (323-41 '�'[' Pl l L(C111C31 (61.01 441(ITIY ACC(73 OUR (47.31 ~ 32-5/1 41-3111 2.1116 3116 F (020.11 1.1:21.0] 132.11 I 11.11 -� 1-114 �-21-5/6 I.1/e .�- 4-0/11 L 1231.13 (361.31 1250.31 LIFT SEE Y RICNT Y (172.21 FEINT SCE YEW (EAR YEW I 18ES50021,1 n 3.0 D 8 E 48ES-A • PHYSICAL DATA i Irk Einn g0 -e UNIT SIZE 24040 24060 - 30040 - 30000 30000 30090 42060 42090 NOMINAL COOUNG CAPACITY(ton) 2 2 2-1/2 2-1/2 3 3 3-1/2 3-1/2 • NOMINAL HEATING INPUT(Btu/hr) 40,000 60,000 - 40.000 60,000 60,000 90,000 60.000 90.000 SHIPPING WEIGHT"lb. 311 311 316 316 326 328 420 420 SHIPPING WEIGHT"(kg) 141 141 143 143 148 148 191 191 COMPRESSORS Scroll s Quantity 1 REFRIGERANT(R-410A) Quantity lb. 4.8 4.8 6.2 62 6.4 6.4 6.1 8.1 i Quantity(kg) 2.2 2.2 2.8 2.8 2.9 2.9 2.7 2.7 REFRIGERANT METERING DEVICE TXV OUTDOOR COIL -- - - - Rows...Fins/In. 1..21 1...21 1...21 1...21 1...21 1...21 1...21 1...21 Face Area(sq ft) 10.2 10.2 11.9 11.9 15.4 15.4 13.6 13.6 OUTDOOR FAN Nominal CFM 2800 2800 3000 3000 3200 3200 3600 3800 Diameter in. 24 24 24 24 24 24 26 28 Diameter(mm) 609.6 609.6 609.8 609.6 609.6 609.6 660.4 660.4 Motor Hp(Rpm) 1/5(810) 1/5(810) 1/5(810) 1/5(810) 1/5(810) 1/5(810) 1/5(810 1/5(810) Q INDOOR COIL �- -- I Rows...Fins/in. 2...17 2...17 3...17 3...17 3...17 3...17 3...17 3...17 rn Face Area(sq ft) 3.7 3.7 3.7 3.7 3.7 3.7 4.7 4.7 W INDOOR BLOWER -_ CO Nominal Cooling Airflow(Cfm) 800 800 1000 1000 1200 1200 1400 1400 Size in. 10x10 10x10 10x10 10x10 11x10 11x10 11x10 11x10 Size(mm.) 254x254 254x254 254x254 254x254 279.41254 279.4x254 279.4x254 279.4x254 Motor HP(RPM) 1/2(1050) 1/2(1050) 1/2(1050) 1/2(1050) 3/4(1000) 3/4(1000) 3/4(1075) 3/4(1075) FURNACE SECTION* Burner Orifice No.(Qty...Drill Size) Natural Gas Factory Installed 2...44 2...38 2...44 2...38 2...38 3...38 2...38 3...38 Propane Gas 2...55 2...53 2...55 2...53 2...53 3...53 2...53 3...53 HIGH-PRESSURE SWITCH 650+/-15 (pslg)Cut-out Reset(Auto) 420+/-25 1$S-OF;eHARGE/LOW-PRESSURE - SWITCH(Liquid Une)(psig)cut-out Reset 20+/-5 (auto) 45+/-10 RETURN-AIR FILTERSi# Throwaway Site in. 20x20x1 20x24x1 24x30x1 (mm) 508x508x25 508x610x25 610x762x25 1 a 5