Loading...
Permit CITY OF TIGARD REROOF PERMIT 111 a. COMMUNITY DEVELOPMENT Permit#: RER2014-00039 T t G,q R O 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/23/2014 Parcel: 2S110AD08700 Jurisdiction: TIGARD Site address: 10640 SW CANTERBURY LN 6 Project: Pacific Crest Apartments Subdivision: LANG HILL NO.2 Lot: 77G Project Description: Complete tear-off and reroof for Building C,all units at 10640&10670 SW Canterbury Ln. Contractor: MCDONALD&WETLE INC Owner: RIVERSTONE RESIDENTIAL GROUP 2020 NE 194TH AVE 1500 SW FIRST AVENUE, SUITE 1020 PORTLAND,OR 97230 PORTLAND,OR 97201 PHONE: 503-667-0175 PHONE: 503-459-5939 FAX: 503-665-0141 FEES Description Date Amount Permit Fee 07/23/2014 $804.75 Specifics: 12%State Surcharge-Building 07/23/2014 $96.57 Type of Use: MF Class of Work: OTR Type of Const: Occupancy Load: Stories: Height: 0 ft Project Valuation: $59,392.00 General Information Building Area: 0 Re-Roof Area: 0 Roof Class: Tear Off: Yes Overlay: Existing Roof Layers: Parapets: Total $901.32 Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 50 32.1987 or 1.800.332.2344. Issued By: ermittee Signature: 1.1-q)191‘ Call 75 by 7:00 a.m.for the next available inspectio ate. This permit card shall be kept In a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each inspection. Building Permit Application Re-Roof RECEIVED I . 11 c)�i , City of Tigard nttaa 7 /7�� M Permit No.: 0 I I 13125 SW Hall Blvd.,Tigard,OR 97223 1 Plan Review a Phone: 503.718.2439 Fax: 503.598.1960 J U L 1 7 2 014 Dave Other Permit. I I. h t Inspection Line: 503.639.4175 Date Ready/By: Juns: to See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information CITY OFTIGARD TYPE oilliklaDING DIVISION REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction El Demolition Permit fees'are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. El 1-and 2-family dwelling ❑Commercial/industrial Valuation: $ ❑Accessory building ®Multi-family Number of bedrooms: ❑Master builder ❑Other Number of bathrooms: p/Diglj 4/0/70 JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:14)61II_10Z40 SW Murdorli et_ New dwelling area: square feet City/State/ZIP:Tigard,OR 97224 t1 NY t'2f�1 12-/ �'� Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Pacific Crest Apts Bldg C Covered porch area: square feet Cross street/directions to job site: Deck area: square feet /e410 e4 /C 7d Other structure area: square feet (/) —7y0 REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees'are based on the value of the work performed. a s l/'.2 A� d 7G�'� Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Complete tear off and re-roof Valuation: $$59,392.00 Existing building area: 4500 square feet New building area: 4500 square feet ® PROPERTY OWNER I ❑ TENANT Number of stories: Name:Riverstone Residential Group Type of construction: Address: 1500 SW First Avenue,Suite 1020 Occupancy groups: City/State/ZIP:Portland,OR 97201 Existing: Phone:(503)459-5939 Fax:( ) New: ® APPLICANT ❑ CONTACT PERSON NOTICE Business name:McDonald&Wetle,Inc. All contractors and subcontractors are required to be Contact name:Brian Bell licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:2020 NE 194°Ave. jurisdiction in which work is being performed.If the City/State/ZIP:Portland,OR 97230 applicant is exempt from licensing,the following reasons apply: Phone:(503)667-0175 Fax::(503)665-0141 E-mail:brianb@mcdonaldwetle.com CONTRACTOR Business name:McDonald&Wetle,Inc. BUILDING PERMIT FEES* Address:2020 NE 194th Ave. (Meese r er to fee scaatak) City/State/ZIP:Portland,OR 97230 Structural plan review fee(or deposit): FLS plan review fee(if applicable): Phone:(503)667-0175 Fax:(503)665-0141 CCB lic.:44680 Total fees due upon application: Amount received: • cf9"'" Authorized signature: d f This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Brian Bell Date:7/15/14 * Fee methodology set by Tri-County Building Industry Service Board. 1:\Building\Permits\ROOF-PermitApp.doc 10/01/09 440.4613T(II/02/COM/WEB) City of Tigard: Re-Roofing Permit Checklist Page 2-Supplemental Information RESIDENTIAL (One- & Two-Family Dwelling) ❑ REPAIR(major) plan review required by plans examiner: building permit is required when structural changes are made or the space sheathing is removed or replaced. SUBMIT TWO(2) SETS OF PLANS SPECIFYING: A. Roof area and nearest street. B. Attic vents: Provide 1 sq. ft. for each 150 sq. ft. of attic space. Vents shall be located in the upper 1/3 of the roof. Provide 1 sq. ft. for each 300 sq. ft. when eave and attic venting is provided. Note: No permit is required for residential re-roof if not more than two(2) layers of roofing will exist upon completion of the re-roofing. COMMERCIAL (includes multi-family and condominiums) ❑ RE-ROOF: Pre-inspection is required for all roofs sloped 2:12 and less. Please make an appointment by calling the Building Division at 503.718.2439. ❑ PLAN REVIEW: Note: Depending on the conditions noted at the pre-inspection,plans may be required to address any non-conforming items. VALUATION OF PROJECT: $ sq.ft. of roof area Permit Fee based on valuation: $ (see Building Permit Fees chart) 12% State Surcharge: $ 65% Plan Review Fee: $ (Required for major repairs of residential and special purpose roofmg of commercial projects.) TOTAL: $ G:\Brian\Building Permit Applications\City of Tigard ROOF-PermitApp.doc2 NORTH Mk ._ MN eR1oE BLDG.B BLDG.A MINIM ■.. Jam `_ \... 0.14, \ %li avE �i AUKUM BLDG.H PACIFIC CREST ��.. APARTMENTS BLDG.D APARTMENTS. . / , - - T ` 11 e -% ; REROOFFIING ,. I, SHEET lITLE. BLDG.F 'I o BLDG.G t,' `t BLDG.E S'. Pry f) ! CS' / r q O - OF ORT6' - � �� v n..e.,einzoia I 1 a ,_ von r cri, sc?‘ ,-. tircl, 1-4 -1 -i- . 9 rc..-; or, ,, G X14005 OSITE PLAN SHEET NUMBER - ° .�.. E . ,+ A1.1 GENERAL NOTES KEYED NOTES LEGEND OF SYMBOLS .v,AC OPICP NOTATIMB ' nvaer BOOB ow;aoo"waa,rs u wum O rro"oe.E"sK."rtr cowo".wca"."r"axno `' ramr.r es«snao !BRUTE ws wucs..<ca smcnw.+c 'Z7 Mk MAC PD(7. dith wE�sr.»sxncnrcrruwar RCAF Cl rscRa rewaeFwW,wa.e MDr ' McBFUIDE B. BFPO P ALL!NCI urca Emma CaM,nuCnaN ialXOM MO m....,, erb.OF1 lI+RrHrt.tvM®N9.1Anlr+4r91E"oVel 01,- lneni.e��anE rL�mc.eawcs a,m�:aMm.:m". O .�wr r.n aenraFU.rn6ee,a OVERFLOW SUPPER ® - ".. PPP POOP o"w. BPPBP.PAS Cf WAGE PP CONS7B,MN AC PAPIES CND CCM 'w,.n«..en.u"+ww .r U O 'WIMP etn rt.LYC.F srsme. 1 /1 il OM CA PC Of sC nsc 5�: .l� AUKUM • t T : -, CRESTC T T APARTMENTS °` o l °o° 1 ,� O°0 �, 7 ° REROOFING u. \ t i e: e ® PROJECT LL am asc A A ® WET TIRE: i i °� l I °� ROOF PLANS x 1. w aFC BUILDINGS�:v a E. z § O ROOF PLAN-BUILDING"D" StRiD ARMY w b11 as ac oC i j,.a ALB.1C Cf 9C�; aF M� IN� .. 9IEOF OW off A 51294014 T T .p T T s° s-- n, e, ¶ ¶ . 000 O Op° �, O r' •° 4 000 '1' �' 0 0 , -B TM 4. o°0 - r= leorr: s : ': o X14005 o.c I i I 2 6: ;: ,, n ; OF IC I 1 °x A ose I �� A2.5 R••F PLAN-BUILD! "E" 0 ROOF PLAN-BUILDING"C" „� usvii "NO*r.srrac...mar, r..a.+.�...,:a,, Report prepared for:Spec Direct(Free User)on 1/22/2013 4:30:30 PM DIRECT tcrte+c Intertek LISTING INFORMATION OF Malarkey AC/N-36 Combustible or Non-Combustible Deck Slope 1:12 SPEC ID: 16482 Malarkey Roofing Products 3131 North Columbia Blvd. PO Box 17217 Portland, OR 97217 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party, other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.The observations and test results in this report are relevant only to the sample tested.This report by itself does not imply that the material, product,or service is or has ever been under an Intertek certification program. Malarkey Roofing Products 1 16482 I Rev:Sep 18 2008 1:22PM 1 Uncontrolled Copy Page 1 of 4 Report prepared for:Spec Direct(Free User)on 1/22/2013 4:30:30 PM DIRECT CLASS A Deck: Combustible or Non-Combustible Slope: 1:12 (AC/N-36) Vapor retarder (Optional) Vapor retarder consisting of optional glass-faced gypsum or SECUROCKT"' Brand Roof Board (min. %-inch thick) mechanically fastened, either spot adhered or fully adhered with hot roofing asphalt or semi-adhered with insulation adhesive ribbons followed by one or more plies of any combination of the following ply sheets; 500, 506 or ASTM D 2178, adhered with ASTM D 312 hot roofing asphalt or any combination of one or more plies of the following base sheets; 501, 503, 515, 602, 603 or 605 Panoply secured with any combination of the following application methods; • Mechanically fastened • Spot or fully adhered with ASTM D 312 hot roofing asphalt • Adhered with Malarkey 705 Cold Process Adhesive, 727 Modified Membrane Cold Adhesive or ASTM D 4479 cold process adhesive at a rate of 1.5 gals./sq./layer Insulation (Optional) Polyisocyanurate, polyisocyanurate composite, polystyrene, polystyrene composite, glass fiber, perlite, rock wool, wood fiber, glass-faced gypsum or SECUROCKTM Brand Roof Board (min. %-inch thick), gypsum (min. '/2-inch thick) or asphaltic cover boards (min. 1/8-inch thick), any thickness (except as noted) or combination, mechanically fastened, either spot adhered or fully adhered with hot roofing asphalt or semi-adhered with insulation adhesive ribbons Base Sheet One or more plies of any combination of the following base sheets 501, 503, 515, 602, 603 or 605 Panoply or ply sheets 500, 506, secured or adhered with any combination of the following application methods; • Mechanically fastened • Spot or fully adhered with ASTM D 312 hot roofing asphalt • Adhered with Malarkey 705 Cold Process Adhesive, 727 Modified Membrane Cold Adhesive or ASTM D 4479 cold process adhesive at a rate of 1.5 gals./sq./layer Surfacing 1-Ply 502, 350, 601 Premium, 625 Paragon, 650 Panoply adhered with ASTM D 312 hot roofing asphalt or 350, 601 Premium, 625 Paragon, 650 Panoply adhered with Malarkey 705 Cold Process Adhesive, 727 Modified Membrane Cold Adhesive or ASTM D 4479 cold process adhesive at a rate of 1.5 gals./sq./layer or 1020 ESHAIum® SBS cap sheet, adhered with ASTM D 312 hot roofing asphalt or by heat welding or 161 APP Cap Sheet, heat welded Note: The component materials of each system must be applied in the order in which they are listed above. Malarkey Roofing Products 1 16482 I Rev:Sep 18 2008 1:22PM I Uncontrolled Copy Page 2 of 4 Report prepared for:Spec Direct(Free User)on 1/22/2013 4:30:30 PM DIRECT -r t,- For additional product information, visit Malarkey's website at www.malarkevroofinq.com. Evaluated to the following... The roof covering systems in this section have been evaluated for external fire resistance Classifications A, B, C as outlined by the following test methods: • ASTM-E108 - American Society for Testing & Materials'Standard Methods of Fire Test of Roof Covering' • FM-4470, Section 5.1.A- Factory Mutual 'Standard Method of Test for Fire Resistance of Roof Covering Materials' • NFPA-256 - National Fire Protection 'Standard Method of Fire Tests of Roof Covering' • UBC-15-2-94 - Uniform Building Code 'Test Standard for Determining the Fire Retardancy of Roof Covering Materials' • CAN/ULC-S107 - Underwriters' Laboratories of Canada 'Standard Method of Tests for Fire Resistance of Roof Covering Materials' • UL-790 - Underwriters' Laboratories Inc. 'Tests for Fire Resistance of Roof Covering Materials' Each system listing identifies the deck substrate as either non-combustible or combustible. Systems evaluated for combustible decks will provide the same ratings when applied over non-combustible decks. Unless otherwise noted in individual listings, combustible decks shall be sheathed with a minimum 15/32" veneer plywood or minimum 7/16" non-veneer APA rated sheathing panel (oriented strand board panels, structural particleboard panels, composite panels or wafer-board panels) or 3/4" thick solid wood sheathing boards. The component materials of each system must be applied in the order in which they are listed. All components of the system must be listed for external fire exposure by an agency acceptable to the AHJ. Some Roof Covering Systems have been evaluated for other performance characteristics, in addition to external fire exposure. Where applicable, such additional performance characteristics are noted within the specific listing. In all cases, manufacturer's instructions should be consulted for installation procedures and details not covered by these listings. Listed Materials are identified by a label or marking bearing the wording, "Listed Roofing Component", a reference number or code and the WHI Certification Mark. Attribute Value CSI Code 07 30 00 Steep Slope Roofing Roofing: Deck Type Combustible Roofing: Deck Type Non-Combustible Roofing: Fire Rating Class A Roofing: Maximum Slope 1:12 Listed or Inspected LISTED Report Number 3105702-006a Malarkey Roofing Products 1 16482 I Rev:Sep 18 2008 1:22PM I Uncontrolled Copy Page 3 of 4 Report prepared for:Spec Direct(Free User)on 1/22/2013 4:30:30 PM DIRECT cm Criteria UBC 15-2 (1994) Criteria NFPA 256 (2003) Criteria ULC S107 Criteria FM 4470 Section 5.1.A Criteria UL 790 (2004) Criteria ASTM E108 (2005) Intertek Services Certification Listing Section ROOF COVERING SYSTEMS Malarkey Roofing Products 1 16482 I Rev:Sep 18 2008 1:22PM I Uncontrolled Copy Page 4 of 4 ,7z;:, LOW SLOPE ROOFING SYSTEM SPECIFICATION Roofing Products THREE-PLY CONVENTIONAL 502 (Base, Ply & Cap) System Configuration %%2j/-2//-/%.j% j M3-AHA(515,500,502 cap) // ROOF DECK/ %/./ MECH.ATTACHED iY""�HiS5 5G�36`rcry� /./"COVER BOARD//j OR FULLY ADHERED M3-BHA(501,500,502 cap) //i/// //, // M3-BIA(501,506,502 cap) './7///////2///2 BASE SHEET Materials per 100 sq./ft.of roof area: ///jj//j///j//' � ), INTERPLY i Base Sheet Options(choose one of the following): 7.-///�/////// FULLY ADHERED I One(1)ply of 515 25.0 lbs. ///////,././%/.,/,.../ � .i J, ..i One(1)ply of 501 30.6 lbs. ////////2/// �;. Ply Sheet Options(choose one of the following): ��/j��/j�j One(1)ply of 500 7.2 lbs. //////////, / ` One(1)ply of 506 9.2 lbs. /////////7/// / / �,: Cap Sheet: /////// // One(1)ply of 502 72.0 lbs. //j///./ I Adhesive for roofing plies: ASTM D 312 Type III,or IV 71///11. 25.0 25.0 lbs.per ply/per sq. //////. •,•'' Insulation: Specified ////�% t //////. ' f ': CAP SHEET Weight per square(-insulation): 179.2 lb.s to 184.2 lbs. //%�// FULLY ADHERED //j /// Roof deck and general information: Roof deck must be j/. Af? clean, dry, smooth, and structurally sound to receive the new /// roofing system. Drainage must be incorporated in the design //,/ ';`( -;;r to prevent ponding water. For more information, please refer Three ply,hot mopped,built-up roofing system with conventional fiber- to the current Malarkey Specification Manual:General require- glass base,ply,and cap sheet installed over an approved roof deck. ments and Commercial Installation Instructions. Special requirements:This roofing system can be installed as illustrated on slopes up to 1"in 12".Slopes that are greater than 1" in 12"are to be installed in a strapped fashion using ASTM Flashings: Install all primed flashings (lead, metal, scuppers, D 312 Type IV asphalt, and wood nailers/insulation stops to etc) in a layer of plastic cement on top of the inter-ply and facilitate back nailing of the roofing system. For more informa- stripped off with two plies of reinforcement,feathering each ply Lion,please refer to the current Malarkey Specification Manual: 3"from the edge of the flange and corresponding ply. Install General Requirements/Strapped Installations. surfacing after all flashings have been stripped in. Application: Hot Mopped-install base sheet according to in- Base flashings: Base flashing stripping ply(s) are to be in- structions in section 4-5 of this manual.Turn up all cant strips stalled over the inter-ply before the installation of the cap sheet. and down all roof edges. Install all inter-plies so that the water Stripping ply(s)are to extend 3"beyond the toe of the cant and runs over(shingle fashion)or parallel to(strapped), but never up the vertical surface of all flat to vertical transitions (curbs, against the laps in a uniform mopping of hot asphalt at the walls,roof top equipment, etc).After the installation of the cap nominal rate of 25 lbs. per ply, per square. Broom all plies to sheet, install the specified cap sheet base flashing extending ensure contact between the asphalt and the bottom surface of 6"beyond the toe of the cant and up the vertical surface.Ter- the roofing felts.Back nail all felts at the wood nailers(strapped minate the base flashing as shown in the commercial roofing installations only) using 1" cap head nails 1"from the leading details of the current Malarkey Specification Manual. edge,ensuring that each nail is covered by the specified num- Fire Ratings: The specification carries a Class 'A' rating up ber of inter-ply sheets. Cap sheet will be installed so that the to 2" in 12"over the following decks:Wood, Metal, Concrete, water runs over(shingle fashion)or parallel to (strapped), but Lightweight Concrete, Structural Wood Fiber, and Gypsum. never against the laps. Cut cap to 1/3 of the total length (11') The exact listing for this roofing system can be found in the and allow to relax prior to installation. Position cap membrane current edition of the lntertek/Warnock Hersey Directory of List- for installation and embed into a uniform mopping of asphalt ed Products. For other ratings, contact the Malarkey Technical applied at the rate of 25 lbs. per square. Ensure contact be- Services Department. tween the asphalt and the bottom of the sheet.Stagger all end laps a minimum of 12". Note: When installing this system over an insulated roof deck, the base sheet attachment will change from a me- Valleys and Waterways: Prior to the application of interply chanical to fully adhered. sheets, all valleys and waterways shall receive an extra layer of Malarkey ply sheet(or comparable product)which shall be at least a full width sheet and shall extend at least 12 inches(30 cm)up to the inclines out of the valleys. REV. 12/11 4-14 Specification Manual www.MalarkeyRoofing.com•800-545-1191 b TECHNICAL PRODUCT DATA SHEET c3 COL S aducts Cap sheet - adhered in hot asphalt Color: Black 70 CAP FIBERGLASS CAP SHEET Note:Malarkey Roofing Products (Malarkey)Inventory SKU numbers for this product:502 Product Description Product Use:502 Panocap is a fire-rated (FR) cap sheet manufactured to meet the needs of a conventional, quality built-up roofing system.502 Panocap can be applied with hot mopping asphalt or cold process adhesives.502 Panocap is used as a surface sheet for multiple-ply roof systems.Please consult Malarkey Technical Services for approval of roof systems.Approved for use on all fire-rated built-up roofs. Composition and Materials:502 Panocap is manufactured on fiberglass mat uniformly impregnated and coated on both sides with bitumen (asphalt) compounded with a fire-retardant mineral stabilizer and surfaced with ceramic granules for ultraviolet protection and weatherability. Technical Data ROLL PROPERTIES TYPICAL RESULTS Weight/Roll(nominal) 72 lbs(32.7 kg) Dimensions 39%"wide x 33' long (1 M wide x 10.0 M long) Granule Adhesion Max 1.0 gram loss,per ASTM D4977 Thickness (nominal) 105 mils As manufactured meets or exceeds the requirements of UL 55A Type G3 and ASTM D3909. Typical Properties, 1.0 square roll Listed with FM, UL and Intertek/WHI. Application Application Procedure:502 Panocap shall be applied as specified.See Malarkey Specification Manual for specific installation instructions.Contact Malarkey's Technical Department for details. Precautions:502 Panocap requires dry storage and protection from the weather.Roof decks should be sound, dry, smooth, meet necessary local requirements,and provide positive drainage.Do not apply wet cap sheets. Technical Assistance:Malarkey has technical services assistance available.Contact Malarkey for details at(800)545-1191 or (503)283-1191, weekdays 7:00 am to 5:00 pm Pacific Time. Warranty Malarkey Roofing Products®offers various warranties to meet specific requirements.The warranty package for 502 Panocap includes 5, 10, 15, and 20 year limited and unlimited coverage.Contact your roofer, local distribution center or Malarkey for full details. 502 Panocap and other Malarkey products are available throughout North America and Pacific Rim countries. Visit WWW.MALARKEYROOFING.COM for additional product information and availability. Effective 5/14 I Supersede all previously published data Check for more current version at WWW.MALARKEYROOFING.COM Corporate Office:3131 N. Columbia Blvd., Portland, OR 97217-7472•P.O. Box 17217, Portland,OR 97217-0217 Telephone:503.283.1191 •800.545.1191 • Fax: 503.289.7644 WWW.MALARKEYROOFING.COM „,.A.,,'. _,,,,,, .. I1IaI'k TECHNICAL PRODUCT DATA SHEET Reefing Products o Ply sheet - adhered in hot asphalt 1 1 ‘J • FIBERGLASS PLY SHEET Note:Malarkey Roofing Products®(Malarkey)Inventory SKU numbers for this product:500 Product Description Product Use: 500 Panoply®4 is a ply sheet suitable for use as an interply in multi-ply roof systems. 500 Panoply®4 may be used over various combustible and non-combustible decks as the initial ply in conjunction with insulated roof systems. Please consult Malarkey Technical Services for approval of roof systems. Composition and Materials:500 Panoply®4 Sheet is manufactured on a fiberglass mat impregnated with asphalt and treated with a non-stick agent to facilitate unrolling. No mineral release is used. Technical Data ROLL PROPERTIES TYPICAL RESULTS Weight/Roll (nominal) 36 lbs(16.3 kg) Weight/Square (nominal) 7.2 lbs(3.27 kg) Dimensions 39%”wide x 165'long (1 M wide x 50.3M long) Lay Lines 2",9%", 121/2",and 183/4" (50.8mm, 238.1 mm,317.5mm,476.2mm) Breaking Strength MD:44 Ibf/in(7.7kN/m) XM:44 lbf/in (7.7kN/m) As manufactured, meets the requirements of UL 55A,Type G1 for asphalt content and minimum weight. Typical Properties,5.0 square roll Complies with ASTM D2178 Type IV and listed with FM, UL and Intertek/WHI. Application Application Procedure: 500 Panoply® 4 shall be applied as specified with base sheets and/or surfacing. See Malarkey Specification Manual for specific installation instructions.500 Panoply®4 may be applied in cold weather. Follow cold weather application instructions and general requirements.Contact Malarkey's Technical Department for details. Precautions:500 Panoply®4 requires dry storage and protection from the weather.Roof decks should be sound,dry,smooth, meet necessary local requirements, and provide positive drainage. Do not apply wet ply sheets. Do not mechanically attach ply sheet to any deck.A base sheet should be specified for mechanical attachment. Ply sheets are are not recommended for cold process application. Technical Assistance: Malarkey has technical services assistance available.Contact Malarkey for details at(800)545-1191 or (503)283-1191,weekdays 7:00 am to 5:00 pm Pacific Time. Warranty Malarkey Roofing Products®offers various warranties to meet specific requirements.The warranty package for 500 Panoply®4 includes 5, 10, 15, and 20-year limited and unlimited coverage. Contact your roofer, local distribution center or Malarkey for full details. 500 Panoply®4 and other Malarkey products are available throughout North America and Pacific Rim countries. Visit WWW.MALARKEYROOFING.COM for additional product information and availability Effective 5/14 I Supersede all previously published data Check for more current version at WWW.MALARKEYROOFING.COM Corporate Office:3131 N.Columbia Blvd., Portland, OR 97217-7472• P.O. Box 17217, Portland, OR 97217-0217 Telephone:503.283.1191 •800.545.1191 • Fax:503.289.7644•WWW.MALARKEYROOFING.COM malariww TECHNICAL PRODUCT DATA SHEET Rbarlag [5-17= Base sheet - adhered in hot asphalt ®- A FIBERGLASS BASE SHEET Note:Malarkey Roofing Products®(Malarkey)Inventory SKU numbers for this product:515 Product Description Product Use: 515 Panobase is suitable for use as a base sheet for hot asphalt, cold process or torch-on application. This standard quality base sheet may be used over various combustible and non-combustible decks as the initial ply for specified roof systems. Please consult Malarkey Technical Services for approval of roof systems. Approved for use on all fire-rated built-up roofing. Composition and Materials: 515 Panobase is manufactured on a fiberglass mat impregnated with hot asphalt and coated on both sides with a hot asphaltic material and surfaced with a mineral release material. Technical Data ROLL PROPERTIES TYPICAL PROPERTY Weight/Roll(nominal) 75 lbs(34.0 kg) Weight/Square min. (nominal) 25 lbs.(11.3kg) Dimensions 39%"wide x 99'long (1M wide x 30.2M long) Lay Lines 2", 4", 12W, and 183/4" (50.8mm, 101.6mm, 317.5mm,476.2mm) Thickness 50 mils As manufactured, meets the requirements of ASTM 04601 Type II. Typical Properties, 3.0 square roll Complies with and listed with UL, FM and Intertek/WHI. Application Application Procedure: 515 Panobase shall be applied as specified. See Malarkey Specification Manual for specific installation instructions. 515 Panobase may be applied in cold weather. Follow cold weather application instructions and general requirements.Contact Malarkey's Technical Department for details. Precautions: 515 Panobase requires dry storage and protection from the weather. Roof decks should be sound,dry,smooth, meet necessary local requirements, and provide positive drainage. Do not apply wet base ply sheets. Technical Assistance: Malarkey has technical services assistance available.Contact Malarkey for details at(800)545-1191 or (503)283-1191,weekdays 7:00 am to 5:00 pm Pacific Time. Warranty Malarkey Roofing Products offers various warranties to meet specific requirements. The warranty package for 515 Panobase includes 5, 10, 15,20,25 and 30-year limited and unlimited coverage. Contact your roofer,local distribution center or Malarkey for full details. 515 Panobase and other Malarkey products are available throughout North America and Pacific Rim countries. Visit WWW.MALARKEYROOFING.COM for additional product information and availability. Effective 5/14 I Supersede all previously published data Check for more current version at WWW.MALARKEYROOFING.COM Corporate Office:3131 N. Columbia Blvd., Portland, OR 97217-7472• P.O. Box 17217, Portland, OR 97217-0217 Telephone:503.283.1191 •800.545.1191 • Fax: 503.289.7644•WWW.MALARKEYROOFING.COM maaari. TECHNICAL PRODUCT DATA SHEET [Togging P[fraditiMF Base flashing sheet - adhered in rf hot asphalt VOD CAP SBS MODIFIED CAP SHEET Note:Malarkey Roofing ProductsTM(Malarkey)Inventory SKU numbers for this product:601 Product Description Product Use: 601 Paragon® MOD Cap with fiberglass mat is a fire-rated (FR) mineral cap sheet manufactured to meet the needs of a high-performance, high-quality built-up roofing system. This cap sheet can be applied with hot mopping asphalt or cold process adhesives. 601 Paragon® MOD Cap is used as a surface sheet for multiple-ply roof systems. Please consult Malarkey Technical Services for approval of roof systems.Approved for use on all fire-rated built-up roofs. Composition and Materials: 601 Paragon® MOD Cap is manufactured on fiberglass mat uniformly impregnated and coated on both sides with bitumen (asphalt) compounded with a fire-retardant mineral stabilizer and surfaced with ceramic granules for ultraviolet protection and weather-ability. Technical Data ROLL PROPERTIES TYPICAL RESULTS Weight/Roll (nominal) 100 lbs(45.4 kg) 39N"wide x 34' long Dimensions (1 M wide x 10.3M long) Granule Adhesion 0.5 gram loss Thickness(nominal) 120 mils As manufactured meets or exceeds the requirements of ASTM D3909. Typical Properties,4"selvage, 1.0 square roll(Test Method:ASTM D5147) Listed with FM, UL and Intertek/WHI. Application Application Procedure:601 Paragon®MOD Cap shall be applied as specified.See Malarkey Specification Manual for specific installation instructions. Contact Malarkey's Technical Department for details. Precautions:601 Paragon®MOD Cap requires dry storage and protection from the weather.Roof decks should be sound,dry, smooth, meet necessary local requirements,and provide positive drainage. Do not apply wet cap sheets. Technical Assistance: Malarkey has technical services assistance available.Contact Malarkey for details at(800)545-1191 or (503)283-1191,weekdays 7:00 a.m.to 5:00 p.m. Pacific Time. Warranty Malarkey Roofing Products offers various warranties to meet specific requirements. The warranty package for 601 Paragon®MOD Cap includes 5, 10, 15,and 20-year limited and unlimited coverage.Contact your roofer, local distribution center or Malarkey for full details. 601 Paragon®MOD Cap and other Malarkey products are available throughout North America and Pacific Rim countries. Visit WWW.MALARKEYROOFING.COM for additional product information and availability. Effective 5/14 I Supersede all previously published data Check for more current version at WWW.MALARKEYROOFING.COM Corporate Office:3131 N.Columbia Blvd., Portland,OR 97217-7472 P.O. Box 17217, Portland, OR 97217-0217 Telephone:503.283.1191 800.545.1191 Fax: 503.289.7644•WWW.MALARKEYROOFING.COM COMMERCIAL ROOF FIBERBOARD G,P ., HFIBEIBASE !!EL " *, ROOF FIBERBOARD i I /+ .�"' ,w.' �c .:r • ti -esa."'' -�s}�? *T�y{rY r,s ei3a ri -,� r ~• ,'''''"=-"•-•,-; _ ,'1. 1� r.,7,1;,' ` f1 i Lt it W`'�• r ` r�,.� r X414 .,r1 7� c.n r";:.,,,, t.r .r• - .wsum��r` t o ,1 7 r } s S- F -0.1 r s. { r - i .- i 1pz.. ct,, m 1 .� t 7 ' r r• 5f.uv 11041/4,.. s.s.r,..Twtoolgitii *I:,,v,, }`.fir �.,� `.'":,...,..2.-q:„.,---.,..`.;.-�' ^i ca ;£,ry"i High-Density Fiberboard ��.c } f , . _� `�Yy ' -- Cyr,F•r...taif ,...„7 Panel for Premium Performance ~~y 3� �:.�f. 1, SIZES TRUE ASPHALT COATED ON SIX SIDES Thicknesses: 1/2'; 25/32';1" Dimensions: 4'x4',4'x8' FiberBase HD Excel`" is Georgia-Pacific's premium,high-density fiberboard panel,coated Pieces per Unit:90,60,45 on all 6 sides, with a true asphalt sealer to enhance moisture resistance and help APPLICATIONS extend adhesive coverage efficiency. Flat, uniform and dimensionally stable, it is an •Cover board over existing roof in excellent cover board for roof system applications.FiberBase HD Excel also adds supplemental recover applications insulation value to help reduce heating and cooling costs.In addition,its lightweight composi- n Protective layer over low-density insulation tion eases handling strain and allows easy cutting with a utility knife.FiberBase HD Excel helps ®Substrate for the following systems: increase roof resistance to hail impact and routine traffic during and after installation. -Fully adhered EPDM single-ply Produced and proven for more than 50 years,specify FiberBase HD Excel , membrane roof systems -e` -Modified bitumen roof systems when you need a premium fiberboard roofing substrate. r .. - -Built-up roof systems 4, Mechanically fastened roof systems Loose laid ballasted roof systems ..GP.,,. Georgia-Pacific COMMERCIAL ROOF FIBERBOARD GP, GENERAL DESCRIPTION FI BE FkBASE EXCEL" Composition:Cellulosic Wood Fibers, ROOF FIBERBOARD Binders and Asphalt C6S PHYSICAL PROPERTIES THICKNESS Density:High Density ,t Coating:Asphalt Coated 6 Sides(C6S) ASTM TEST/STANDARD 1/2" 25/32"" 1" Linear Expansion(max) ' ,..-Ii:"'M' C2o9/0.5% 0.3-0.5% .1.3-0.5% 0.3-0.5% SAFETY&SUSTAINABILITY ,�.ke,.r: Water Absorption(max) C209/7.0% 0 5.0-7.0% -.0-7.0% 5.0-7.0% E WARNING-Do not apply flame to a� Cl 5/20 FiberBase HD Excel.When applying Compression Strength(PSI min.) gl 20 20 20 4 Ar modified bitumen membranes,a Tensile Strength Parallel to Surface OS avg mf;i D1037/150 150-200 150-160 150-160 base sheet is required.FiberBase Tensile Strength Perpendicular to Surface(PSI min.) 17,4-',.:.,. 01037/600 600 600 600 HD Excel may smolder and burn. g k" T' Extinguish completely if ignited. Transverse Load Either Direction(avg min lbs) ', e) C209/120/24),24(1•) 12-16 23-25 24-25 = y., u Georgia-Pacific procurement prac- Modulus of Rupture(Psi avg.min.) C165/275(1/2°),140(.) 1 275-400 160-200 140 tices are certified to conform with Thermal Conductivity)V ._ __ , 0518/0.40 0.40. 0.40 0.40 the Sustainable Forestry initiative' Thermal Resistance Same as R.vatue(F tf men!) C518/1.32 Cif),2.64(t) 1.32 2.06 2.64 program objectives 8-20 of Section 2-SFI 2010-2014. Yb 1.STM xCVi6xd notashM t>2SJ2- SPECIFICATIONS COMPLIANCE ®Green Building-The specification For Re-Roofing(Cover Board)Applications:Existing and usage of FiberBase HD Excel can FiberBase HD Excel"meets or exceeds the requirements roof surface must be cleared of all gravel and other debris help contribute toward credits in sus- for Type II,Grade 2 panels referenced in ASTM C208-12 before applying FiberBase HD Excel.Surface irregularities tainable building rating systems such (Standard Specification for Cellulosic Fiber Insulating Board) must be smoothed or scraped flat.FiberBase HD Excel as LEED,the NAHB Green Building and/or CAN/ULC-5706(Standard for Wood Fibre Insulating and deck must be dry prior to installation and kept dry Standard and others: Boards for Buildings).FiberBase HD Excel surpasses the during the re-roofing process. LEED MR 4:Pre-Consumer ASTM's minimum standards for transverse load by up to Recycled Content 17%,creating a stiffer panel that is especially valuable RECOMMENDED FASTENER PATTERNS when used in mechanically attached roof systems where LEED MR 5:Local/Regional Materials resistance to wind uplift is a design requirement. When mechanical fasteners are used,the patterns below (Where applicable) FiberBase HD Excel is available coated 1 side(CIS)by are recommended for these commonly specified numbers LEED E0 4.4:Environmental Quality of fasteners.(Consult the roofing membrane manufac- special order. lure.for recommended size and quantity of fasteners (For more information about sustainable building center- q ry butions.contact your Georgia-Pacific representative.) FiberBase HD Excel is also available by special order as required for a specific job.) an Underwriters Laboratories'classified product under the UL File 811115 for built-up roof covering materials. SPECIAL ORDER: See the listing under Roof Covering Materials(TEVT)in la Coated 1 Side(CIS) the UL Roofing Materials and Systems Directory. n UL Classified WIND UPLIFT INFORMATION FiberBase HD Excel is a Factory Mutual Global approved 4'x 8' 4'x 4' LIMITATIONS: roof insulation for 1-60 and 1-90 wind uplift rated systems 8 fasteners per board 4 fasteners per board m DO NOT apply flame to FiberBase as outlined in reports J.1.1 T6A2.AM(C1 S),J.1.2M3A2.AM HD Excel.When applying modified (C6S)and J.J.0V7A2.AM(CIS).FM allows FiberBase HD bitumen membranes,a base sheet • Excel wherever wood fiber insulation is specified. (Consult the roofing membrane manufacturer and the current Factory Mutual Global is required.• approval guide for systems compatibility and specrc application instruction u) u Follow membrane manufacturers • - INSTALLATION REQUIREMENTS a'x a' a'x a' instructions in single-ply membrane applications. if fasteners per board 6 fasteners per board When installed according to these instructions,FiberBase HD Excel provides a flat,uniform substrate for optimum - -. . membrane performance. • For Insulation Protection Applications:Offset FiberBase HD Excel panel joints at least 6"from under- - • lying insulation panel joints.Spacing at all FiberBase HD - Excel joints should not exceed a maximum of 1/8". 4 x 8 4'x 4 16 fasteners per board 8 fasteners per board Panels must be dry before and during application.Apply only as many sheets of FiberBase HD Excel as can be Mlninium fastener spacing at corners 6"from either edge SUSTAINABLE Maximum fastener spacing at corners 12"from either edge ® FORESTRY covered by the roof membrane during the same day. APPROVED INITIATIVE Al4t , Georgia-Pacific Georgia-Pacific Wood Products LLC 133 Peachtree Street,N.E. I Atlanta,GA 30303 I 1-800-BUILD GP I www.buitdgp.com Fberease HD Excel,George-Facdic and the GP logo are trademarks caner spas r lensed to Georgia.Pacec Wood Products LLC.02013 George-Pacifc Nb-e Pnducls LLC.Al rgh's re;erred. Sustairade Forestry Irldatiwe is a registered trademark Owned by Sustainable Fdresay Inebtive Inc.Primed in the USA 052222 Lit.Item 1621695 H U N T E R P A N E L S E N E R G Y S M A R T P O L Y I S O H-SHIELD Flat Polyisocyanurate Insulation H-SHIELD THERMAL VALUES THICKNESS LTTR FLUTE (INCHES) (MM) R-VALUE* SPANABILITY 1.00 25 5.6 2 5/8" 1.50 38 8.6 4 3/8" 1.80 46 10.2 4 3/8" 2.00 51 11.4 4 3/8" 2.50 64 14.4 4 3/8" /,11,, ,,,,,..v.4 ; -, ,er ,� 2.60 66 15.0 4 3/8" > `? :a" 3.00 76 17.4 4 3/8. V. ` 7p x +44 W4r i _ r - 3.50 89 20.5. 4 3/8" 0+ r,rt y4 3.80 97 22.3 4 3/8" H-Shield " , 3 ,z 4.00 102 23.6 4 3/8" �r '<k rte=, .r T*7 4.30 109 25.5 4 3/8" 4.50 114 26.8 4 3/8" NEW Long Term Thermal Resistance Values are based on ASTM C 1289, effective 11112014,which provides updated 15 year time weighted averages. PRODUCT DESCRIPTION H-Shield is a rigid roof insulation panel composed of a closed cell polyisocyanurate foam core manufactured on-line to Codes and Compliances fiber reinforced facers on each side. • ASTM C 1289 Type II,Class 1 Grade 2(20 psi)or Grade 3 (25 psi) • International Building Code(IBC)Chapter 26 FEATURES AND BENEFITS • State of Florida Product Approval Number FL 5968 • • Manufactured with NexGen Chemistry: Contains no CFCs, Miami Dade County,FL NOA NO:09-0915.15 —Exp. 1.14.2015 HCFCs,is Zero ODP,EPA Compliant,and has virtually no GWP Underwriters Laboratories Inc Classifications • Approved for direct application to steel decks • UL 1256 • Insulated Metal Deck Construction Assemblies-No. 120, • Approved under all major roof covering systems - BUR, 123,292 Modified and Single-Ply • UL 790 • PANEL CHARACTERISTICS • UL 263 Hourly Rated P Series Roof Assemblies • Available in two grades of compressive strengths per UL Classified for use in Canada ASTM C1289 Type II, Class 1 Grade 2 (20 psi) or Refer to UL Directory of Products Certified for Canada for Grade 3 (25 psi) recto D' more details • Available in 4'x4' (1220mm x 1220mm) and 4'x8' (1220mm x 2440mm)panels in thicknesses of 1"(25mm)to 4.5" (114mm) Factory Mutual Approvals • APPLICATIONS FM 4450,FM 4470 Approved for Class 1 insulated steel deck constructions for Constructions requiring FM Class 1 and UL Class A ratings 1-60 to 1-270.Refer to FM Approval's RoofNav for details Single-Ply Roof Systems (Ballasted, Mechanically Attached, on specific systems Fully Adhered) LEED Potential Credits for Polyiso Use(PRE LEED V4) , •. Standing Seam Metal Roof Systems For current LEED V4 contribution information go to g Y www.PIMA.org or www.hpanels.com • Modified Bitumen Systems Energy and Atmosphere • Optimize Energy Performance • Measurement& Verification • Built-Up Roofing:Asphalt and Coal Tar Materials&Resources • Material Reuse •Construction Waste Management • Recycled Content • Local and Regional Materials Innovation and Design W W W . H U N T E R P A N E L S . C O M • 8 8 8 . 7 4 6 . 1 I 1 4 H U N T E R P A N E L S E N E R G Y S M A R T P O L Y I S O TYPICAL PHYSICAL PROPERTY DATA CHART WARNINGS AND LIMITATIONS PER ASTM C 1289 POLY/S0 FOAM CORE ONLY Insulation must be protected from open flame and kept dry at all PROPERTY TEST METHOD VALUE times. Install only as much insulation as can be covered the same Compressive ASTM D 1621 20 psi* day by completed roof covering material. Hunter Panels will not Strength (138kPa, Grade 2) be responsible for specific building and roof design by others, Dimensional ASTM D 2126 2%linear change for deficiencies in construction or workmanship, for dangerous Stability (7 days) conditions on the job site or for improper storage and handling. Moisture Vapor ASTM E 96 < 1 perm Technical specifications shown in this literature are intended to be Transmission (57.5ng/(Pa•s•mz)) used as general guidelines only and are subject to change without Water Absorption ASTM C 209 < 1%volume notice. For more information refer to the Storage and Handling Technical Bulletin at www.hpanels.com,or refer to PIMA Technical Service Temperature -100°to 250° F Bulletin No.109:Storage&Handling Recommendations for Polyiso (-73°C to 122°C) Roof Insulation at www.polyiso.org. *Also available in 25 psi, Grade 3 Single-Ply Systems INSTALLATION Ballasted Single-Ply Systems Each H-Shield panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. Mechanically Attached Single-Ply Systems Each H-Shield panel must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. Fully Adhered Single-Ply Each H-Shield panel must be secured to the roof deck with fasteners and plates(appropriate to the deck type). Maximum 4'x4'(1220mm x 1220mm)panels of H-Shield may be adhered to a prepared concrete deck or subsequent layers of insulation with a full mopping of hot steep asphalt,insulation adhesive or cold applied mastic. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. R-30.0, two layers of 2.6" H-Shield with Built Up, Coal Tar And Modified Bitumen Systems Single-Ply membrane Each H-Shield panel must be secured to the roof deck with fasteners and plates(appropriate to the deck type). Maximum 4'x4'(1220mm x 1220mm)panels of H-Shield may be adhered to a prepared concrete deck or subsequent layers of insulation with a full mopping of hot steep asphalt, insulation adhesive or cold applied mastic. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. HUN + ER Energy Smart Polyiso HUNTERPANELS.COM 15 FRANKLIN STREET, PORTLAND, ME 04101 888.746.1114 • FAX: 877.775.1769 :�,WU TM Lit (� PI e PIMA NEXCEN (PAPER /1 O ` AQualityMark' ,elfl[OLYANU*II INSULATION 7;7 • ' ME may-C` The Cerhhed LTTRvolee Nu1NUSACi°N[IIL•[fenAiwN sov WRM F'SC 10YIee SOY INK NEW YORK • ILLINOIS FLORIDA • TEXAS • UTAH • PENNSYLVANIA WASHINGTON 1213 H U N T E R P A N E L S E N E R G Y S M A R T P O L Y I S O TAPEREDEl-SHIELD Sloped Polyisocyanurate Insulation # �Y, PROFILES yTti/� T _ • ft•i� i..a�`j� 4 rr��eCl• FILL eccSW • Tapered H-Shield h t <i t ' ,•dd O‘}°— ,max ® ' arc— e.e ./•,smear fF. PRODUCT DESCRIPTION Codes and Compliances • Tapered H-Shield is a sloped rigid roof insulation panel ASTM C 1289 Type II,Class 1 Grade 2(20 psi)or Grade 3(25 psi) composed of a closed cell polyisocyanurate foam core International Building Code(IBC)Chapter 26• State of Florida Product Approval Number FL 5968 manufactured on-line to a fiber reinforced facer on both • Miami Dade County,FL NOA NO:09-0915.15—Exp. 1.14.2015 sides. Tapered H-Shield is designed to promote positive drainage and prevent ponding water. For best results,request Underwriters Laboratories Inc Classifications assistance from Hunter Panels Tapered Design Team. UL 1256 •FEATURES AND BENEFITS • Insulated Metal Deck Construction Assemblies — No. 120, • Manufactured with NexGen Chemistry: Contains no CFCs, 123,292 HCFCs,is Zero ODP,EPA Compliant,and has virtually no GWP ' UL 790 • UL 263 Hourly Rated P Series Roof Assemblies • Approved for direct application to steel decks UL Classified for use in Canada • Approved under major roof covering systems BUR, Modified ▪ Refer to UL Directory of Products Certified for Canada for and Single-Ply more details PANEL CHARACTERISTICS • CCMC 13460-1 Available in two grades of compressive strengths per • UL Certified for Canada,CAN/ULC-5126,CAN/ULC-S101, • ASTM C 1289 Type II,Class 1 Grade 2(20 psi)or Grade 3 (25 CAN/ULC-S107 psi) Factory Mutual Approvals • Available slopes are Y,6" (2mm), ''/e" (3mm), 3/16" (5mm), '/" • FM 4450,FM 4470 (6mm),%"(10mm)and 'h"(13mm)per foot • Approved for Class 1 insulated steel deck constructions for 1-60 Available in 4'x4' (1220mm x 1220mm) and 4'x8' (1220mm x to 1-270. Refer to FM Approval's RoofNav for details on specific • 2440mm)panels in thicknesses of.5" (13mm) minimum to 4.5" systems. (114mm)maximum in a single layer LEED Potential Credits for Polyiso Use(PRE LEED V4) - Other panel sizes and facers are available upon special request For current LEED V4 contribution information go to www.PlMA.org or www.h panels.com APPLICATIONS Energy and Atmosphere • Constructions requiring FM Class 1 and UL Class A ratings • Optimize Energy Performance • Measurement&Verification Materials&Resources • Single-Ply Roof Systems (Ballasted, Mechanically Attached, • Material Reuse •Construction Waste Management Fully Adhered) • Recycled Content • Local and Regional Materials • Modified Bitumen Systems Innovation and Design • Built-Up Roofing:Asphalt and Coal Tar �- W W W . H U N T E R P A N E L S . C O M 8 8 8 . 7 4 6 . 1 1 1 4 H U N T E R P A N E L S E N E R G Y S M A R T P O L Y I S O TYPICAL PHYSICAL PROPERTY DATA CHART WARNINGS AND LIMITATIONS PER ASTM CIE Insulation must be protected from open flame and kept dry at all POLYISO FOAM CORE ONLY P P P rY times. Install only as much insulation as can be covered the same PROPERTY TEST METHOD VALUE day by completed roof covering material. Hunter Panels will not Compressive ASTM D'1621 20 psi' be responsible for specific building and roof design by others, Strength (138kPa, Grade 2) for deficiencies in construction or workmanship, for dangerous Dimensional ASTM D 2126 2%linear change conditions on the job site or for improper storage and handling. Stability (7 days) Technical specifications shown in this literature are intended to be Moisture Vapor ASTM E 96 <1 perm used as general guidelines only and are subject to change without Transmission (57.5ng/(Pa•s•m2)) notice. For more information refer to the Storage and Handling Technical Bulletin at www.hpanels.com,or refer to PIMA Technical Water Absorption ASTM C 209 < 1%volume Bulletin No. 109:Storage&Handling Recommendations for Polyiso Service Temperature -100°to 250°F Roof Insulation at www.polyiso.org. (-73°C to 122°C) Also available in 25 psi, Grade 3 INSTALLATION Single-Ply Systems Ballasted Single-Ply Systems —_ a Each Tapered H-Shield panel is loosely laid on the roof deck.Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. p i Mechanically Attached Single-Ply Systems � r , 7 Each Tapered H-Shield panel must be secured to the roof deck with fasteners and plates(appropriate to the deck type).Butt edges and stagger Tapered H-Shield joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. Fully Adhered Single-Ply Each Tapered H-Shield panel must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Maximum 4'x4'(1220mm x 1220mm) panels of Tapered H-Shield may be adhered to a prepared concrete deck or subsequent layers of insulation with a full mopping of hot steep asphalt,insulation adhesive or cold applied mastic. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. Built Up, Coal Tar and Modified Bitumen Systems Each Tapered H-Shield panel must be secured to the roof deck with fasteners and plates(appropriate to the deck type). Maximum 4'x4' (1220mm x 1220mm) panels of Tapered H-Shield may be adhered to a prepared concrete deck or subsequent layers of insulation with a full mopping of hot steep asphalt, insulation adhesive or cold applied mastic. Butt edges and stagger joints of adjacent panels.Install the roof covering according to the manufacturer's specifications. HUN + R Energy Smart Polyiso HUNTERPANELS.COM 15 FRANKLIN STREET, PORTLAND, ME 04101 • 888.746.1114 • FAX: 877.775.1769 aetl /a` TT eECrouo rl PIMA [NEGEN' PAPER ,�X \ nalityMark` ,OOIfDCYA111111ATE INSULATION ;;too \CN Be The CerK/'ed LiTRavfu° rEAwurACruf LAS ASSOCIATION ° IIIIMt[o xml FSC FIC C102/°s SOY INK NEW YORK • ILLINOIS • FLORIDA • TEXAS UTAH • PENNSYLVANIA • WASHINGTON csia 1 . 1 . 1cloIEIFI . I . IJIKILI . INIp1 . 1 . 1sITiulvI . I . I , I , 1 , ABC- Supply Co.inc.. _ 2 BUILDING B TAPERED — ■e■-■...-‘.ma- -amig, SOLUTIONS TIIM...-■.--.4791rt,_■■11■19.■.--.9.1771r11.■■•1111Z1b..- -... POW- /al Ct=1.t*.ar 3 temb...-.4.1.1, 11. 111111111. PROPIII%11121111111111...11■ ■1/1111 r Znorring' ei..._ —4400...- ■so■-. ,dimmnb..._ ■ C.a.1.......M.c.. =.111ki■ /1111111M. C C 1 AMIN■a■ I C 1 M2+ C C MIN•1■1■K!Ifiill 1=1: 111046.1.s_41 11111: 01110PIPIPI1169.-1111■9941117-4.-4111190.-1211466-11: 1111rh-- -"41Mh:111111 If.■■••---j=19.... 11.-W.....aViM ""i1=119..■.ii PIPPP ///eglibb■ -.IMO! 1g. ig 571 4eli 6 1faW....4111. 111011■11=aai ■grLI I'V 4..■■...1 a 02.. CO ■.■ Cr ° 7 4... I: BUILDING A co g _ !1`■-■91.--.472r4.."%l■-alINI1r17 l■ p. 9 111119..._ ---. PPM- /Me'MIN.,■,Q7C4- 11 C.) IMMIlilli.... 11111.111111111.- 01,0111111%2ITEMIbt.-WQVIIi■-■1111171 C.) — /111EMIlabbgilirrdliall •F■ c ___ f r f ACI 9 c AO* 0 C N m 1 1 1■•■•,23 a■1■1 C 0. ■11. .,r,■119. 1,V KR rr TAPTITO MSC ITCT(21 ■.. IlirlillErl C ■• .741■, ■111 ,11.■•■ 10 I ..iiii01111 .111 C MIPIPM..- .../1024.111al■ .."1114P 001 ■•• 011441 iLMWAIlliraMaialli _ .‘11%.. ..ii -071r. • -..iiIIIIMOIN■._ 'till ....,.. •....‘04 li ,s1Lo- i&W..w41011..-v..--■ai WI ,...., 1.•* rciLy ....a*POR .... CA.V. f.,14-r,ri;4,4folrim 12 __...A......412r—AYArMINNIMI / man au _ 4/13/201. — BUILDING D 11,r Pr.FT TAKOCO[MS ... .... t3 N.1=11.■,011V13"■•■•91 511•1•11...W23.p .aMINI311 . -'4111.0111PP..- /11111 — 5TI■■■. ..M1117110191..- ---' 71111,10.11%1111111.Z.bit.._ /110111. Chin- -'41100111PP.- /al IIIMMIli... .' /1111=1111liddElMIM . 14 =1.111b.- ' ■41fillEM . MINNINCI■C"...■ C ii■ 2=NLA ... ■MINE■WiF:1■1■1 C 0° %MOHO ■1•4■T.:1:14 C■11■ c 15 MI=11 ,174■1■11■• Err: c =:.21111001%14/ DATE IIIII Pi II MI MI!.i i Willi igitill _il r"'- -a d a i 1•P..M II a I...- ...Mil Conon.Holm ..07C01101:" _ .- 'gill! lar,•-- ..--1:-:-A:sat.z..--:.-- ,6 pp, __iiilowink,_. ..-_-....=. iL....---....----oon,„_-.•■_-ww _ laiMil ==.7•■,:e.='. .. 17 Eara ne■W2==. -.. to 1 of 2 1 . 1 . 1 . 1 . 1EI , Ici . i , IKILI . 1 . 1e1 . 1 . isiTiulv1 . 1 . 1 , Izi , ABC Supply Co.k)c ..._ 2 BUILDING E TAPERED — BUILDING C SOLUTIONS :=1:rmi 3 ?V■ii.--.. .a1=••■91 ellib.. .11118/001r."- --.811211■WQT.M.■••■21 011.._ —watior- _..../Me■-■._-,gayar■-■71 tri= C..4•44.0•V14.4.4 — IIIIIIV- -./111111M-11100111:11 IIIII.V.■ IiiIIMMIIII144-Waallai 111111. 111.:M MIIIMMIIIIIIIIIIMIEMillIIIIICIIIII 4 MMUMMIEEMEMMEMilli C 1111111.1=11.11111M ' C VIM•••■•17..■■ • illl■ .u,,o,, 1■1■.:-.-•.■■ C — C 1 ..7M41■MEN4A■1 .■., ..,,,. . CO c 5 c — _ 011111°111"111.1.-.01111110111.16-172111117a9.-: 100 ....diarar. -..IIIIIMIll 1=1°- . .$6161%111.1■1114M196.-: -'414MMIll c iEl■-■111M111prIWIMaillipPl/ -...118.- BEll iLM1/■-■11/Aiki...W■11111/1110 6 ACP. ....-.111r......... .0110V._ irn■Ilywipitt■il■-wia I.. CU < g 7 1 4.7 c; 0 5. BUILDING G a) i 8 C.) n !■■■-,W7r1:0•■■ITIrv■....■ ■P■"--■IITENsh._■..--cP!M■11.••■•11 _ Iliglid ■Addirebb.--.411111:Mit = -.111.711PICIPIIIIIIIIIIPP'-01.11111=.11. 11,11111111 frfr r .0 .._ 9 11111111 AZgi 0 CU MIIIII1111111.1=M= 101=111..111.1111 c CLC — 1■1 _704■11114:■1•0111II:MI■M■ 1/■•On CT TOPTOCR MOSS WV= .1 M I 1 1 IIR.101111 ai I r I 1■0•=.I.I:1 s•0 I C I MI 1 EMMMI 1■I:I•■.■■.1 a 10 1111=1.11111111111111. 111. C I - =:=P%I" 10.1.0■■•%01111"111M111= 11::%100///%1■ le■Miggill■ '141111P1MIMail■ ■IICIP'itiMiailb.._ ■11. f I ■CAri.or4rikerici 11,0); AdirkeavAtv —....-11.-"" 4C1.0. hrOso4 OR 11 i&M-.Y...01118.-Ya..■LlaiLmw_Alliffm.,WMiliiL■d.Y_Ie.118.--womai VC 04mA —..w.M.N.. M."..1111. V.••aMnv., ra ea ..IONA er1L, ....aro.. — JiriN111.10a0ELSMILIELO011 .... ....., 12 p.r .-..7,.., .ft AttAns. — BUILDING F —. •w,‘ 3.. 13 RINNIII.■.--,tra 114,...r■-■?1 P.M. YR V !!`■..._■._-"t43M•ill■-■INWAICAlib.._ --.4111111 - /II _ , H I litiliM0111111=1=1.■ -.8111.1 mmilm=1111111111M1. c.r c I.C..i.;•:■779.1 vAr A. ■16■ limmin 2 r5150., ••,. -n C 50510555 ■•••■•101■0L11,!■IM 10 1 C CI- OM .1=11.1111"11 =111=1111 "IIIIIIIM 16 -All1110°111°- "q11111IrlW--all1111MlialtIL dig111011111111j11:1P._ 14111411114,■-M- -.111 airn■Irrigalir■-■111■--Wli -vr— C.o.No1n: .=2.,......-.,.-,..„.. ___ -.MIL CR•RWenen ...■.1—la=... BUILDING H .....-_,....:.„... _I to 2 of 2 FESCAF, PLUS CART STRIP tZli TAPERER FESCU®EUG[ STRIP Johns Manville Perlite-Based Specialty Accessory Product Features and Components ,; °,▪� Component Expanded Perlite:Provides good dimensional stability and excellent ,ti, r B insulation value with stable R-value.The high perlite content offers A, t "� 9* of Cover Board far greater fire resistance than conventional wood fiber materials. `` `1 _ t H '- Multi-Ply Reinforcing Cellulosic Fibers:Consists of recycled newsprint to Type provide strength to the board as well as high recycled content. PL JM utilizes third party certification by UL®environment to certify Perlite the recycled content and contributes to the LEED®Materials and r_, s Resource(MR)credit 4. •Expanded Perlite LT •Reinforcing FesCant Plus Cant Strips:Manufactured from JM Cant Board,a Cellulosic Fibers trnv Thermal high-density,laminated perlite board that provides excellent transition i . •Selected Binders from the deck to the wall of the roof. Tapered Fesco Edge Strips:Excellent for transitioning from membrane j....rL. to nailer,or transitioning from Tapered Fesco®,Tapered ENRGY 3®, or Tapered Fesco Foam panels to the roof level to help promote positive drainage. System Compatibility This product maybe used as a component in the following systems.Please reference product application for specific installation methods and information. a BUR APP SBS a HA CA CA._ .,HW. . _.HA CA. .HW * Compatible with the selected Multi-Ply systems above in Do not use in Single Ply systems Key: HA= Hot Applied CA = Cold Applied HW= Heat Weldable SA = Self Adhered MF= Mechanically Fastened FA = Fully Adhered BA= Ballasted Energy and the Environment Installation/Application Cant Strip:39%average LEED® Recycled Content Edge Strip:33%average ,ft�f Far post and pre-consumer recycled content percentages,visit the __ rrA Fesco Board product page on the JM rooting Web site. 410. ENVIRONMENTAL Hot Asphalt Cold Applied Urethane 0 CLAIMS 'FesCant'"an average Strip Adhesive contains an average of VALIDATION 39%recycled content. Refer to the Application Guides and Detail Drawings for instructions. Packaging and Dimensions ENVIRONMENTAL g g CO CLAIMS 'contain an avT Edge Strip contains Fe average of Product FesCant Plus Cant Strip VALIDATION 33%recycled content. Sizes E.x 3" 1"x 4" 1.5"x 4" 1.5"x 5" Strips/Bundle 33 21 30 18 Bundles/Pallet 30 30 20 20 Peak Advantage® Guarantee Information Linear Ft/Bundle 120 84 120 72 Lb/Bundle 20 20 30 30 Systems Guarantee Term* Pallet Weight(lb) 600 When used in most JM multi-ply or single ply systems. 10,15 or 20 years Pallets/Truck* 48 Product Ta'ered Fesco Edge Strip "Contact JM Technical Services for specific systems or terms over 20 years. Sizes 0.5"x 6" 0.5"x 12" 1"x 12" 1"x 18" 1.5"x 12" 1.5"x 18" Codes and Approvals Strips/Bundle 72 36 28 18 12 12 Bundles/Pallet 14 14 10 10 16 10 ��P551f/eo ® Linear Bundle Ft/Bundle 288 144 112 72 48 48 "'""`°"D�`O1'r''' BET/Bundle 36 36 56 54 36 54 C U5 MiamlDsd•counry Lb/Bundle 60 35 93 50 60 60 APPROVED P,oduct Lonrrol approved , Pallet Weight 840 _ 490 933 500 960 600 Pallets/Truck* 48 Producing Location Rockdale,IL "Assumes 49'flatbed truck. Refer to the Material Safety Data Sheet and product label prior to using this product The Material Safety Data Sheet is available by calling(800)922-5922 or on the Web at www.im.com/roofing. RS-5049 4-14(Replaces 2-14) •'f +J+. ... +f: _. .. *4 it '_rzt"..i,#.2 t „p .—. gp„.,,t ,.t.a: ti 21747 i',' FESCR� It,' PEUS CR�� STDIP ''TT fF ire TAPERED FESCU [DGE STRIP .„,,,4,,,,,,,,,,,E.1,1 Johns Manville r . Perlite-Based Specialty Accessory Product& 7 Typical Physical Properties* Test ASTM FesCant Plus Cant Strip* Tapered Fesco Edge Strip* Product Density,pcf(kg/m3) C 209 12(192) 9(144) Compressive Strength,psi(kPa) 5%Consolidation C 165 35(241) 30(207) ti 10%Consolidation 50(345) 40(276) Laminar Tensile Strength,psi(kPa),min C 209 4.9(34) 7(48) Flexural Strength,psi(kPa) C 203 60(414) 65(448) Water Absorption,%by vol(2 hr),max C 209 3.5 1.5 i 0 w. Linear Expansion,%max C 209 0.5 0.5 'Fes Cant Plus Cant Strip is manufactured from 14'Perlite board in ASTM C 728,Tapered Fesco Edge Strip is manufactured from 3/4"Perlite board in ASTM C 728. Thermal Performance Test ASTM FesCant Plus Cant Strip Tapered Fesco Edge Strip Flame Spread E 84 30 25 Smoke Developed E 84 20 10 Refer to the Material Safety Data Sheet and product label prior to using this product. The Material Safety Data Sheet is available by calling(800)922-5922 or on the Web at www.jm.com/roofing. RS-5049 4.14(Replaces 2-14) N CORNINUlENS G T ru m b u I I Product Information Sheet TRUMBULL BUILT-UP ROOFING ASPHALT Description Trumbull's Built-Up Roofing Asphalt products are manufactured from selected petroleum based materials and processed to various softening points and penetrations, meeting required specifications as outlined in ASTM D-312. It is supplied in tank vehicles and cartons. Typical Physical Properties Property Range — Type I Type II Type III Type IV Color Dark Brown to Black Softening Point ASTM D-36 135-151°F 158-176°F 185-205°F 210-225°F ASTM D-5 Penetration @ 77°F 18-60 dmm 18-40 dmm 15-35 dmm 12 - 25 dmm 100 grams, 5 sec. ASTM D-5 Penetration @ 115°F 90-180 dmm 100 dmm 90 dmm 75 dmm 50 grams, 5 sec. max. max. max. Flash Point (COC)ASTM D-92 500°F minimum Solubility in trichloroethylene (%) 99.0 minimum Sept-01 Asphalt Technology Lab- 7800 West 59th Street- Summit, IL 60501 - 708.594.6971 } i f pr.., ;x . t; � F.'� 9 s , {f t -�p �it J r j ;:S aa` e w t g - . , ,��3,3t aF,a- s i - -rY_ i , 'r 3 � . . _ k 3 - ...--..4.-,,-,„, „3•.:4,,r , � t, ,s ,, x4� ,/2'M, -,4 *=- , . : Standard RoofGrip e Drill Point Fastener '� PRODUCT DATA SPECIFICATIONS PRODUCT DESCRIPTION APPLICATION The 0MG Standard RoofGrip Drill Point The 0MG Standard RoofGrip Drill Point _ USE Fastener(#12)is designed to secure Fastener must penetrate steel decks a WITH insulation to standard steel(18 ga.-24 ga.) minimum of 3/4-in.,wood plank decks a •/ and wood.It is available in lengths from minimum of 1-in.and 1/2-in.through the F r 15/e-in.to 8-in.The 0MG Standard RoofGrip underside for plywood decks.Using a Drill Point Fastener is Factory Mutual and screw gun,*drive the fastener until a slight i DECK Miami-Dade County approved. depression is seen in the insulation around TYPES the plate. FEATURES & BENEFITS Note:Care must be taken not to PHYSICAL DATA O Heavier shank and thread diameters overdrive the fastener and fracture the The data below is constant for each 0MG Standard than most"standard”roofing fasteners. skin of the insulation.Fastener must be RoofGrip Drill Point Fastener. O Deep buttress thread for high pullout tight enough so that the plate does not turn. HEAD THREAD resistance. For steel decks,Factory Mutual requires #3 Phillips .220"Diameter Y Extra sharp drill point for quick that the fastener penetrate the deck at the Truss Head** installation in new or reroof top SHANK flute. .435"Diameter applications. .160"Diameter To speed installation,this fastener can G Available with#3 Phillips truss head. be used with the AccuTrac®System and COATING COATING is also available pre-assembled.See CR-10 AccuTrac or ASAP®. 0MG CR 10 corrosion resistant coating **#3 Phillips bit included in each carton. exhibits less than 15%red rust after 30 PLATES & ACCESSORIES Kesternich cycles.CR 10 coating exceeds ORDERING INFORMATION F.M.Approval Standard 4470. Use appropriate steel or plastic plates, depending upon the application.See CAT.NO. LENGTH THREAD PKG WEIGHT Plates section. RGDP158B 15/s" Full 1000 12 lbs. *For best installation result, use a variable RGDP214B 21/4" Full 1000 16 lbs. speed 0-2500 RPM screw gun. See RGDP0036 3" Full 1000 24 lbs. Accessories section. RGDP004B 4" 3" 1000 28 lbs. APPROVALS RGDP005B 5" 3" 1000 35 lbs. ® RGDP006B 6" 4" 1000 40 lbs. RGDP007B 7" 4" 1000 48 lbs. I.Untrunrry RGDP008B 8" 4" 1000 50 lbs. KEY: ..0® 10 Steel ®Structural Concrete ®Wood El Lightweight Concrete ROOFING P R 0 D U C T S Gypsum 0X Lightweight Insulating Concrete irj Purlins ©Cementitious Wood Fiber MADE IN USA FASTENERS ADHESIVES DRAINS PIPE SUPPORTS 3�r('� x`''��i'•+,4�£�#'.,» 1 aLt 9:.-J'411 Vi+ s:.�•v � sap°z� y, r., +.,a3HJ�i >-7c? :fa __.... �i .,, �X.`F�rs_c._. �� rt �r t- 4k�.a�Y"Y rr ; Standard RoofGrip Drill Point Fastener PRODUCT DATA SPECIFICATIONS SPECIFICATION STANDARD ROOFGRIP The fastener will be an OMG Standard RoofGrip Drill Point Fastener(#12)with DRILL POINT FASTENER a thread diameter of.220.The fastener must have 12.5 buttress threads per LENGTH S E L E C T I O N inch.Also,the fastener must be heat-treated per specification 0MG-1.The PROCEDURE 0MG Standard RoofGrip Drill Point Fastener will be used with a Factory Mutual 1. If applicable,determine the thickness of approved,OMG round pressure plate or pressure bar.The fastener must be the existing roofing material. Factory Mutual approved and made in America. 2. Add thickness of new insulation. COATING REQUIREMENT 3. For steel:Add 3/-inch minimum fastener The fastener will be coated with the OMG CR-10 corrosion resistant coating. penetration. When subjected to 30 Kesternich cycles(DIN 50018),the fastener must show 4. If odd size requirement,always size up in less than 15% red rust and surpass Factory Mutual Approval Standard 4470. length,not down.See example: APPLICATION Your The OMG Standard RoofGrip Drill Point Fastener must penetrate steel decks a Example: Project: minimum of 3/4-in.,wood plank decks a minimum of 1-in.and%z-in.through the Existing Roofing 13/4" underside for plywood decks.Using a screw gun,*drive the fastener until a Cover Board slight depression is seen in the insulation around the plate. Min.Penetration 3/4" 3/4" Note:Care must be taken not to overdrive the fastener and fracture the skin Total Fastening 3" of the insulation.Fastener must be tight enough so that the plate does not turn. Correct Length 3" Factory Mutual requires that the fastener penetrate the steel deck at the top flute. The proper#12 standard RoofGrip Drill Point Fastener for this *For best installation result,use a variable speed 0-2500 RPM screw gun. See steel deck example is 3'/.inches. Accessories section. PHYSICAL DATA The data below is constant for each OMG Standard RoofGrip Drill Point Fastener. HEAD THREAD #3 Phillips .220"Diameter Truss Head .435"Diameter SHANK .160"Diameter PACKAGING COATING 1000/carton CR-10 OMG. ROOFING PRODUCTS 153 BOWLES ROAD, AGAWAM, MA 01001 800.633.3800 WWW.0LYFAST.COM INFO@OLYFAST.COM AccuTrac and ASAP are registered trademarks of OMG,Inc.Copyright©2011 OMG,Inc.AD rights reserved. AccuTrac Plate t 4 ,„4, ,,,,' PRODUCT DATA SPECIFICATIONS i .Y. t1 ! PRODUCT DESCRIPTION APPLICATION .1 ,.% 4 OMG AccuTrac Steel Insulation Plates are For use with OMG manufactured#12 stan- =' made of Galvalume°coated steel and are dard fasteners,#14 heavy duty fasteners, ' 4-40-,-,. available in two designs. #15 fasteners,and the OMG AccuTrac Tool ; � s A 3-inch square,recessed AccuTrac Plate to attach insulation. ,,.. > ''=r.77-7.f 1.0 eua0 ; is to be used with OMG manufactured Hex APPROVALS -' head fasteners,Phillips head fasteners or square drive fasteners. A 3-inch square,flat-bottom AccuTrac Plate PHYSICAL DATA is to be used with OMG manufactured -^ The data below is constant for each OMG AccuTrac Plate. Phillips head fasteners only. MATERIAL SIZE OMG AccuTrac Steel Insulation Plates should be used when fastening insulation Galvalume®coated steel 3"square with the OMG AccuTrac Tool. ORDERING INFORMATION FEATURES & BENEFITS CAT.NO. STYLE PKG WEIGHT • Factory Mutual and Dade County BKT6862904 Flat 1000/bucket 43 lbs. approved. BKT6123904 Recessed 1000/bucket 43 lbs. o Recessed AccuTrac Plates feature deep reinforcing ribs for superior resistance to bending. - o Flat-bottom AccuTrac Plates can be used r with hard board insulations. ®' ° Using the AccuTrac System can improve ";`t installation productivity when compared to traditional installation methods. '?- o AccuTrac Plates are packaged 125 per n sleeve for easy loading in the AccuTrac `) Tool O AccuTrac Plates are packed in weather- AccuTrac Plates are designed ,t■ proof buckets along with two Phillips to be used with the ergonomically drive bits. ,i correct stand-up AccuTrac Tool. I:1 1 'l AID 0MG ROOFING PRODUCTS ,�'�� 153 BOWLES ROAD, AGAWAM, MA 01001 - , 800.633.3800 WWW.0LYFAST.COM INFO@OLYFAST.COM MADE IN USA AccuTrac°is a registered trademark of OMG,Inc.Copyright©2009 OMG.Inc.AD rights reserved. Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 10640 SW CANTERBURY LN 6, TIGARD, OR, 97224 Commericial - Reroof 299 Final inspection PASS - No C of O RER2014-00039 Chip Barnett Violation Summary: Inspector Contractor