Loading...
Specifications GENERAL STRUCTURAL NOTES 121,11_0_0_1&&g.1 G4: DESIGN WAS BASED 014 THE STRENGTH AND DEFLECTION CRITERIA OF THE 2003 INTERNATIONAL BUILDING CODE. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS WERE USED FOR DESIGN, WITH LIVE LOADS R.VDUCED PER IBC: aQp. E IR33 T5: CONFORM TO THE 2003 INTERNATIONAL BUILDING CODE AND THE SEISMIC PROVISIONS FROM THE ASCE 7-02, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES. 5XIS TINO COND1'I`14NS:- THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES FROM CONDITIONS SHOWN ON THE DRAWINGS PRIOR TO THE START. OF THE WORK '1'EMPORARV COND1f QI1 THE CONTRACTOR SHALL BE RESPONSIBLE FOR STRUCTURAL_. STABILITY OF THE NEW AND EXISTING STRUCTURES AND WALLS DURING CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER THE FINAL CONFIGURATION ONLY. C .L SAWN LUMBER DESIGN IS BASED ON THE NATIONAL DESIGN SPECIFICATION, LATEST EDITION. SAWN LUMBER SHALL CONFORM TO WEST COAST LUMBER INSPECTION BUREAU OR WESTERN WOOD PRODUCTS ASSOCIATION GRADING RULES. ALL LUMBER NOT SPECIFICALLY NOTED TO BE DS. Lt2 OR BETTER. ALL WOOD IN PERMANENT CONTACT WITH CONCRETE OR CMU SHALL BE PRESSURE TREATED UNLESS AN APPROVED BARRIER IS PROVIDED. FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON STRONG -TIE COMPANY (OR ENGINEER APPROVED EQUAL) AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS AND ATTACHED PER MANUFACTURER'S REQUIREMENTS AND RECOMMENDATIONS UNLESS NOTED OTHERWISE. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF SIZE RECOMMENDED FOR MEMBER- ALL FRAMING NAILS SHALL BE COMMON NAILS. NO BOX NAILS ALLOWED. FASTENERS AND ACCESSORIES IN CONTACT WITH PRESERVATIVE TREATED WOOD MUST BE HOT DIPPED GALVANIZED OR HAVE ZMAX COATING. META L.,S: ALL MISCELLANEOUS STEEL: ASTM A36 (FY- 36,000 PSI) WELDING: PER AWS STANDARDS. E70XX ELECTRODE AND BY CERTIFIED WELDERS. ALL STEEL TO HAVE SHOP COAT. pA ANICAL: ALL SEISMIC RESTRAINT OF ASSOCIATED PLUMBING, PIPING OR DUCTING SHALL BE BY OTHERS UNLESS NOTED OTHERWISE ON THE PLANS. FLASHING AND W,AT RPROOF O 0114- ALL FLASHING AND WATERPROOFING SHALL BE EY OTHERS UNLESS NOTED OT g ` PLANS.. �or cry u• • r• r" 13 - 14, " 20 t c J M rURN D1PIRES: oggi of a�yyi7�z+v Qf�L�(�(1rw' t _ _ .�... //�f''1F� -� A Air S� C EN GIN 1 131 \, `� Y TN � V Q [ y , � } 6Y ll ow YG �.�_Y.�.1 l GGNsua�wa +s - �5�5l4,.+ SW 1"l N `V - #1 lb cnx BY DATR 7659 S.W. $ld St. Suite 100 -' _ � to 11129; Tigard, Oregon on 97 97223 — - Phone: (505) 443-3900 or c 26 .4)L (-)". ROOF TOP UNIT RTU: 3 -TON MECHANICAL UNIT = 460 CURB WT — 115 ECONOMIZER = 47 ALTERNATE MOTOR y - POWER EXHAUST — - OTHER = - TOTAL WEIGHT = 622 LB NCE DRAWINGS: DWG. Al — FLOOR PLAN, MILDREN DESIGN GROUP, JOB # 10517 DWG M1 — 1 DUCTING PLAN — GOHMAN MECHANICAL INC. JOB # J3806 DWG S3 AND S4, ROOF FRAMING PLAN & DETIALS- BLDG B. VLMK JOB# 98073 ROOF FRAMING KEYNOTES 1. NEW ROOFTOP MECHANICAL UNIT (3 -TON NOMINAL CAPACITY). 2, NEW 4X6 OF 42 FRAMING MEMBER CENTERED ON NEW MECHANICAL CURB. 3. SIMPSON `LUS46' FACE MOUNT HANGER PROVIDE (8) 16D NAILS AT EACH HANGER TYP. 00.162" L- 3 -I /2") 4. PROVIDE NEW 2X FRAMING AROUND MECHANICAL UNIT DUCTS AS REQUIRED. 5. CONNECTION AT GIRDER SIMILAR TO SKETCH SK2. %ilekr A9 +1°1 N F4 , cat �+.r � 20 .'� 0 ' r do . ' .p .14 2° � q' �C? 1p� TURt4 DcPtR£S' �)s�Ji1"r MN TM RIPPEYap.h1A 1 7_00 0 V1Tf} nY 0114 n,.,i3 fG /3)Ob — CLINAL1VO E HZERS $ W 1 1 1 cilK Dxm 7650 S.W. Bcvcland St, sows 100 ,, E b� •Z1 JOHNo 1v2gl Tigard, Oregon 972x3 Phone: (903) 443-3900 attar Z of t0 .004L. . 1 �. . . -_ C0 WPr4C * z ' 0 f z9,e, AC, Q I T c 2 -,T, U. M wr. 0 Fcxxt, 4 t40 -S . Ct1T74-13 11.S 1, 1" "t:L PPP L- - v KIDS 1 b o E w f 1e5r V c.-w► PBfiF,t PAI --TPEK-1 bWa v-+.a (.44:24.)? 1 ' £ a f ' ' A t "r' L... nzklit.04G Pt,i5chl " 4 .': , car o • a Gakie � s 1Lon "�Y 20.34. S S ruRo p' [ Es: i 1 if TM RTP Y . Ci ,Nn llll CONSULTING FNGENAtliS p f , ,, 1 1 Q llJj �} LM NY GATE 7650 S.W. seveland St, suite 100 "1 t -D c>g °1 R22-4 JOB tro fd2..'7"1 Tigard, Oregon 97223 Phone (503) 44339410 sir 3 OF (p 1 • isa ..._ • Fecri- 1 • Zcus7 fPv\i..- / ./ s)115 . . . FtiaD,M ! 1 . . I S WA I Pr.I41 r. AlltIV '..1 I I 0 I li 2 v - Ara• , . .- Ararat-mar x x r .... .... , ........ ....• 1 GoSENe. / ATIV6464vi , • 14 kizep.... liS(15 \ i SNA,1 NI \ 141/NaLEz_ \ gccr 7tcZET c \ . 1 C 7. C•• 4 • 1111, • , , • ' , • • - . .. .. •.. .. .. . • • _ ... •- ._ ... .... . .. 4 9.tt Pilliff Ve 1 N o d ) - -- • 4.4, 7.-- • - . , ,..- ... . -5) .., ...c. . - - -- GrlcrUtd 0 IME:14.--Ui ' TQFk!sis • ..„ .• se-0%e ": , 1 • :.-- 1 _-c) .. . .. EXPIRES: gym. - : , .. ,, , L.......„ _ ... ..: ... ..i., ..... . . i_i_i •.__, _ ....•-• . ---, . : ,•,,,,, ,.••••,• -,----- ' "7' "' ....... ' • ' ''--'" --"'""; ' -- ' - - - ' ' ' ; :'''' ::" I - i - . ' . - . . . i - ...... • _ --- liv ".. 12-k TIVIRIPPEY ÷—f?---- Zhi-q—W-LI . I • erf __Ii_ tIATErc • CoNSMINC ENGINMSAS t S it OS SIV 1 L4",._ta___ti CL:T!' 01 ay 04Tx _ 7650 S.W. Bevelanci 3t, SuIte.100 r • 0 a 0 . toa No .-- . Tigard, Ores= 9722 3 . . Pbtme (503) 443-39430 ' • - ''''' ' ' : ._...— - __ e L ° Z c, --- G - cA n I i 1/4 LV4. SIS`1 `hii 12i 2x AWN , 1/ 1/2 i . , � t � ci X 11 Ili z1I x t1 1 11 el' — x • t /L x 1% x I I'd' X �' /ate / 13 ____:" .:4 -.- a .._,-1;\ z-c \ , i \ g 1 �� ;\ r / 1! ' i ._.4._.., t ._:___ , . . _ _ 1 7E Jvrw� T Aw4VAWsIMr 74-i \ t .–. 2. ‘t tAliN) ' , " C. OA) t...0 0 • 4 xn- A s 14 x to S��6.1 A . - _ r ,1 a , ?Rot 0 Fr-Pem. . IZPW.44.E1 . - - AO . , 1 4% H rus EXPIRES: , MIMI ;; • 1 M IVX RI PE+Y EPA \ N Q 1 1 1 'W V "\ 1`_____ S 6Y &IL DATE_ i513/06 CONSULTING CNCINEERS l 2 fslo5 a , a � I� _., cHK RV _____, oasE - 7650 S.W. Bevdaad St, Suite 100' .. _ . „ 0,E__5_1_,) pa No 67- T .._ Tigard, Or 97223 �ti� _ � b Phone (S03) 443 -3900 —. , \kkLe c 20 ()C - c ' I ...r-.. f _4: -7------ . • PcV�E ( # �2 `i1% I2 7':�U't' "�' La4c`iE. ap c. TS 1 -d ' r iil: AW • F c C.G12-r4 S oN 4 (W �a�` 1) 1...aN&.7 SZO , Q c,u . (Lk) IS Pf Vv1 ri.or.XT cv a R si... %' 4 F sT, recArZPE. #11 ,s .p JS �'�` `� e 7)- c. PstiAD ils V" RZOM EN'S (A3/ (l lz. tie ReoF hTns1 efesso T41-0 51 pfamotre Fvc7vJOF.4.. ir 01>`C. ; G WIPER- C aP-t3 ON to T Sc.FvJs +N►ikY V7:4 1 "1 cot. F9 ra G?r.DN ►'� 1 E 0 P1101/4 20 0 S Fr--1 7 K) @ C- 0 iz- r5 , so wIF 5 i /z4 c 1 i 0° f`' 2a,1`" J� �`/'j�'� '1I PEY 5'p 1r r•�D 71No�ff RY A 31& LL�L I CONSYL77l4CY..4.....I i s[lv l ,, SVY 7t-r PAT 110 CMK6Y OATS__ 7650 S,W. Bkveland st, Suite 100 - 0 R ' l .r toe No l02.1. Tigaul, Oregon 97223 Phan (503) 44.3-3900 _ SHEET GP CO (4' pc)- / - Form 4a Project Name: BRAND INOVATORS Page: 11 SYSTEMS - GENERAL e Applicability Plans/ Specs Discussion of qualifying Show compliance by including a drawing sheet, detail number, exceptions on page 4-25 specification section and subparagraph. 1. Applicablity (Section 1317) Is this form required? O Form Required. Complete form if a new HVAC system is being installed, or components of an existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area: Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) 0 Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. 0 Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: ❑ -4a ❑ -4b ❑ -4c ❑ -4c ❑ -4e ❑ -4f ❑ -49 ❑ -4r ❑ -4 ❑ -4 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. El Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as required by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) 0 No Distribution Transformers. The plans /specs do not call for new distribution transformers. ❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. ❑ Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: 0-10-2 ❑ -3 ❑ -4 ❑ -5 ❑ -6 ❑ -7 ❑ -8 ❑ -9 ❑ -10 ❑ -1 0-120-120-14 Attach relevant documentation for appropriate exception. The plans /specs show compliance in the - ", ° . following locations: v . t Q 1 " „'l/ - ;',, , ...q-r6; - .,:m e .,' . , i4 , '",...', - ;; , :‘, 1 . - 3 ' ',l : K -, - 9-, . - . 11 3, 7.,,,r,,,:,,,.-,..;;,,,, c ,. „,,,i,. „ 1T ;t. 4-1 r m ,. ,,.,ti rt44:0 Q , /n, Inc iAkLeL7_&eAc) —o L-1-0 Form 4a Project Name: BRAND INOVATORS Page: I 2 SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) M Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception ❑ -1 ❑ -2 Portions of the building that qualify: The plans /specs show compliance in the following locations: 6.2 Of hour Controls - Auto Setback or Shutdown (Section 1317.4.3) M Complies. Systems must have at least one of the following features: ❑ Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces served. ❑ Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: ❑ Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception ❑ -1 ❑ -2 The plans /specs show compliance in the following locations: 6.3 Control Capabilities (Sec. 1317.4.2.1) ❑ Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception ❑ -1 ❑ -2 Portions of the building that qualify: The plans/specs show compliance in the following locations: 6.4 Optimum Start Controls (Section 1317.4.3.2) M Complies. Separate HVAC systems have controls capable of varying start-up time of system to just meet temperature set point at time of occupancy. ❑ Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans/specs show compliance in the following locations: 6.5 Heat Pump Controls (Section 1317.4.4) m No Heat Pump. The plans /specs do not call for a new heat pump ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. 'S The plans/specs show compliance in the following locations: V Cl � = ;'x w.fi v vi,4: -at wA - - ..w ,oEpt.}A 4 k: `a ,, pQ,,,, 'w s 4-2 Comoliance t akieg P•±♦ffective 01/01/Q5 ,1A,4..(..- 21-='(.1c, -- av (A L______ Form 4a Project Name: BRAND INOVATORS Page:1 3 SYSTEMS - GENERAL 4„ +:,.n.rr R.::xa /94 r :2 =:.a.le,ft:1 ,r,. :44:;C.mxw r<r,. :.c �.,;;:r' .xa:s � , z4+. , .7 , 4 :5,,;wc .,d+flivi4 PW': ;M;;,7V >144. N,* ws ,:r, t.„,•:,+,,,„,„i 7. Economizer Cooling (Section 1317.3) ❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling. ❑ Complies. Each new fan system has an air economizer capable of modulating outside -air and retum -air dampers to provide up to 100 percent of the design supply air as outside air. ❑ Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317.3, Exception ❑ -1 ❑ -2 ❑ -3 ❑ -4 ❑ -5 ❑ -6 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu /hr) (b) Total installed building cooling capacity (Btu /hr) ❑ Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 Btu /hr or a/b < 0.10 (10% of total building cooling capacity). Unit Identifier of exempt units: The plans /specs show compliance in the following locations: 8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2) ❑ No Economizers Required. Project does not contain a new fan system requiring economizers. ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. • ❑ Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. ❑ Exception. The applicable exception is Section 1317.3.2, Exception ❑ -1 ❑ -2 The plans /specs show compliance in the following locations: 9. Hot Gas Bypass (Section 1317.5) ▪ No Hot Gas Bypass ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity Allowable Hot Gas Bypass :i > �' Rated Cooling Capacity Max Hot Gas Bypass ' <240,000 Btu /hr >240,000 Btu /hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h T? kfi :I i .- R, "*.d" 2Fm ltu%"' iorAs l bo s�I J►S �° t 3�rsF"!k€ 4.3 Compliance with OSSARQ/01/05 Vc7 o s W C-/ Form 4a Project Name: BRAND INOVATORS Page: 4 SYSTEMS - GENERAL 10. Shutoff Dampers (1317.4.3.3) ❑ Not Required. Shutoff dampers are not required on this project. ❑ Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers. ❑ Exception. The building qualifies for an exception to the motorized damper requirement. The applicable code exception is Section 1317.4.3.3 Exception 0-1 0 0-3 0-4 0-5 0-6 The plans /specs show compliance in the following locations: 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) ❑ Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. ❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. The plans /specs show compliance in the following locations: 10.2. Motorized Damper Leakage (1317.4.3.3.2) ❑ Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. ❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: 11. Piping Insulation (Section 1314) El No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. ❑ Complies. All new piping serving a heating or cooling system or part of a circulating service water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for exception: Section 1314.1, Exception 0- 0 -2 12. Occupancy Ventilation • Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated in plans /specifications as specified in Chapter 4 of the Oregon Mechanical Specialty Code. ❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet 4m. The plans /specs show compliance in the following locations: The plans /specs show compliance 4%-"- on the following pages: °I . `04% 4-4 C..mmnliancp with OAPs t?i`OM/01 /(15 Ate Zv66 -60961 Form 4a Project Name: BRAND INOVATORS Page:I 5 SYSTEMS - GENERAL 'xti ,,,...1.•.1`. - .n:.. - ;.M Y,t L_:::.1 • • -..Y.Yr ^::h.'FY j G.l, ,.e'ti,'... . 5..1 °..31Y:5...1 �4 *!Y/ F••*•Stt!tw - S. XY: _`S SG'':'dY i.:, 13. High Occupancy Ventilation (Section 1317.2.2) ❑ Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: Plans/specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified: ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. Ii No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Exhaust Air Heat Recovery (Section 1318.3) ® Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min. outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air supply. ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception ❑ -1 ❑ - ❑ -3 ❑ -4 ❑ -5 ❑ -s ❑ -7 The plans/specs show compliance in the following locations: 15. Large Volume Fan Systems (Section 1318.4.2.4) ▪ Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans/specs show compliance in the following locations: 16. Variable Speed Drives (Section 1317.10.3.1) Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans/specs show compliance in the following locations: 17. Service Water Heating (Sec. 1315) ® No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. ❑ Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: " 'i' Portions of the building that qualify: "•' The plans/specs show compliance in the following locations: .t 1 ..� .:f F.= -.1 ^ - , `.' Vie': :zc•1� / ... � � ti 4-5 0 , /f14 Nig Form 4a Project Name: BRAND INOVATORS Page: 6 SYSTEMS - GENERAL 18. Swimming Pools, Spas and Hot Tubs (Section 1315.5) la No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) ® No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: ❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or Tess of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: 20. Parking Garage Ventilation (Section 1317.2.3) ® No Enclosed Garages. The building plans and specifications do not call for enclosed Group S- 2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) ® Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. .. ' The plans /specs show compliance in the following locations: .o; 22. Outside Heating Systems (Section 1317.12) ® No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. ❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4-6 _ .. .. , • =' .:;, a ^ry ''nn ('nm .a+,, [ IAA R)d ntmmrns ,. . AA, ZOC(Q. - 06C-1-( ' Worksheet 4a Project Name: BRAND INOVATORS Page: UNITARY AIR CONDITIONER - AIR COOLED Equipment (a) (b) ( c) (d) (e) Proposed Performance Discussion of equipment Cooling Seasonal or Compliance • ratings and equipment Equip. ID Model Designation Capacity Steady State Part Load Schedule (A -E) • definitions on page 4 -19 RTU 1, 2 BRYANT 580FPV036074 36000 10.1 N/A C Required Indicate source of information Document- ❑ ARI Unitary Directory, Section AC, page: ation • ❑ ARI Applied Products directory, Section ULE, page: • ® Product data (Attach data fumished by the equipment supplier, I.e., 'cut sheets') • Code Required Cooling Capacity (btu/hr) Minimum Rating Efficiencies Compliance Seasonal or Schedule Equipment Type Over But not over - Steady State Part Load 0 65,000 na 9.7 SEER Single Package Without a 65,000 135,000 10.3 EER n/a This schedule of equip A Heating Section or With Electric 135,000 240,000 9.7 EER n/a meat efficiencies was Resistance Heat 240,000 760,000 9.5 EER 9.7 IPLV reformatted from code, 760,000 - 9.2 EER 9.4 IPLV Table 13 0 65,000 na 10 SEER Split System Without a Heating 65,000 135,000 10.3 EER n/a B Section or With Electric 135,000 240,000 9.7 EER n/a Resistance Heat 240,000 760,000 9.5 EER 9.5 IPLV 760,000 - 9.2 EER 9.2 IPLV 0 65,000 na 9.7 SEER Single Package With a Heating 65,000 135,000 10.1 EER n/a C Section Other Than Electric 135,000 240,000 9.5 EER n/a Resistance 240,000 760,000 9.3 EER 9.5 IPLV 760,000 - 9.0 EER 9.2 IPLV n � i�a? - =. 0 65,000 na 10 SEER ` Split System With a Heating 65,000 135,000 10.1 EER n/a 0T1 'fl . ,� :: , _ ,; . •. -. i D • Section Other Than Electric 135,000 240,000 9.5 EER n/a Resistance 240,000 760,000 9.3 EER 9.7 IPLV \..ied?. 760,000 - 9.0 EER 9.4 IPLV E Condensing Unit Only 135,000 - 10.1 EER 11.2 IPLV . rtir,MtiOz it areN caxn N r n te ws c _ tWet z aAithr., .. 4-11 Onmplianrt+ with rIcsr: affrntivp n1 H11tn5