Loading...
Plans �9 • h o-j-IL ,.0 f � PROPERTY LINE 225' l(o �' t ? \ , I S 92' -7 1 /2" r. / C4 N \ .46 ACRES / N 'J \ / / \ .R" 777 1000 GAL CONCRETE SEPTIC TANK AND DRAIN FIELD �/ / ' o \ , �. 0 O EXISTING HOUSE // �' 0 ��. NEW;ADDITION Z • w FFE 298' / ; / / 418 SO FT, J -I-- .i FINISHEDJFLOOR ELEVATION Cr) Z / ELECTRIC / \\ `< / ( / //// , �� � SAME AS EXISTING HOUSE >- . METER / / /�/ /P $'/ A SLOPE W -I— W r / // NEW RAIN DRAIN Cl... �� / !����� �� TO STORM LATERAL 0 ON CL TELEF HONE 1/ O • Iz CL PROPERTY AT THE ACTUAL BUILDING SITE DOES NOT SLOPE MORE THAN 20% AND WILL NOT BE ALTERED FOR THE ADDITION . EXISTING POWER POLE • EXISTING GRAVEL `' WATER METER 1' WATER SERVICE DRIVEWAY AND APPROACH PROPERTY LINE 225' GENERAL NOTES LEGAL DESCRIPTION: / � Co- ordinate with trades to provide blocking, penetrations and special framing \ Work shall comply with all applicable governing codes and ordinances for the as required for building systems. L E IT N E R RESIDENCE ( l city of Tigard, Oregon. Notify the owner if there are items shown which do not comply with applicable codes. provide solid blocking in floors and deck areas for coiunms or posts. 503.639 �S O RT 1 1 . LOCATED AT 14985 S W 98TH Use written dimensions only , do not scale the drawings if written dimensions Open guardrails to have a max of 4" clearance between balusters. ZONED R 3.5 Verif dimensions and conditions includin utili connections or to A reference datum elevation of 100' - 0" is set to top of concrete slab at S ETE AC KS, L e I t n e r Site P • Verify including utility addition and at existing building subfloor. FRONT 20 , SIDE 5', REAR 15 commencing work. Notify the owner of discrepancies noted in the field. SCALE 1" = 20' - 0" All work shall be in compliance with the following codes: LOT 006 All windows within a 24 inch arc of a door in the closed position shall be State and local codes - to be verified with local building officia tempered. All windows within 18 inches of the floor and within 12 inches of CABO One and Two Family dwelling Code PARCEL 2 S I I I B D .01400 any door are to be tempered glazing. ACI, AISC, ASTM .46 ACRES Provide insulation baffles at eave vents between raf Contractor to provide all necessary temporary support for walls and floors PLAT - ALDERBROOK FARM All dimensions are to face of stud framing unless otherwise noted. prior to completition of vertical and lateral load considerations. AN ADDITION TO . SHEET 1 Design Criteria: OF 4 All exterior walls shall be 2x6 framing unless otherwise noted. Basic Roof Load for snow 25 # /sq.ff. THE LEITNER RESIDENCE Floors 40 # /sq.ft. 14985 S W 98TH Provide solid blocking for any wall hung items and locate any such items with Wind 80 mph, Expossure B TIGARD, OREGON the owner. Seissmic Zone 3 • •