Plans a 1,0 po/y_ a ©o 3.2_- Pt crags/%v6 ' , pL wi ao q -00035 - w!ell baf c7370 5 i-1 --�, '9iec - 2D 5'. A Single and Twin Vacuum Installation 011On" by MIDMARK For models: ' Note Classic Bronze (all AVB) If installing Separator kit for Twin Vacuum system, Gold Series(all AVG) refer to installation guide for plumbing instructions. Ultra (all AVU) ACaution Mount Platform must have 6"inches of clearance on all sides. Step 1: Remove vacuum(s)and accessories from shipping platform. J Step 2: Move vacuum system to a dry, well ventilated 1 area on a solid, level surface. Note: Temperature of room 40°(4°C)min. - 100°(38°C)max. J Twin Model Shown ,13 `✓j 1 [411010//„ , r, ,WW4+41111 4 - dl% W I 4 Single Model Shown 6" t�,�����‘ (■` ii`I ✓ 6„ „ Single models only Step 3: Mount base feet. i Step 4: Connect PVC Flex Hose from intake manifold to operatory. Note: 1 HP&2HP vacuum use 1 1/2"x 4'hose. J Single Models go to Step 5 Twin Models go to Step 10 AEquiprnentAlefl Harmful odors,vapor contaminants and nitrous oxide gasses are vented out the top of the separator,while liquid waste flows out of the lower drain and into a"P"-Trap or floor sink.Verify all local codes before Installing. — — — J Single Vacuum Models ONLY AEquipment Alert Exhaust separator must be installed no more than 3 ft above vacuums. Separator is adjustable at unions to size for stud location. Step 6: Install anchors into wall studs. Mount Exhaust separator onto wall. J Step 5: Mount Bracket onto exhaust separator. (Step 7: Install external vent. Vent Note :r If vent is connected to wall instead of ceiling, V slope vent away from pump, 1/4"for every 10'. ID tehr.1 *1111100,... ... MI Y,, 1"Air Gap Option 'It ic to !• ,,/Exhaust J Muffler V Route Direct to Drain � Connection ,...41110� AVM % Ilur4b � v Exhaust Connections \\,\�\�\�p� �J M146500i I ' tep 8: Connect exhaust on separator to exhaust on vacuum with 3/4"x 3'flex hose. Note: Secure exhaust unions hand tight. –_ \ Use PVC cement on hose Step 9: Connect 3/4"x 3"flex hose to liquid drain on separator. connections. Connect other end of hose to P-Trap. J Note if P-tmp is not used,connect end of hose to floor drain. Single Models go to Step 11 Specification Sheet 4)011_0" Single Vacuum System 3/4"x 3'Flex PVC MIDARK Exhaust Line 2"PVC Vent Pipe y IVI 1 1/7"P-Trap "Glue at Install" (Provided By Plumber) With 1"Air Gap (Provided) or floor sink _ (Not Provided) Air/Water Separator (Refer To Local �RI (Optional) Plumbing Codes) High Pressure Mgr.() Disconnect Box-Provided By Electrician 1/4"x 6'Hi g Use recommended breaker/fuse size Water Inlet Hose +t_J V r. (1/2",1/4"MPT Or 3/8"Tithe le �� it (Provided) rip Low Voltage Wires See Not: For 24V Remote il Operation (Red And Blue Switching) ` f 1 .) Optional White=Light �J4 / Route Direct To Drain PVC Slip Coupling 116*/ % Connection And MPT Adapter � i (Provided) '11 Flex PVC �_ - Exhaust Inlet Tubing v.; // ��" Muffler(Provided) Vacuum Anti-Siphon Valy- 6'Conduit and Incoming Water Line (Provided) 'Note:Some local codes require a reduced pressure backflow preventor on the incoming water line. 14n145900aiJ Breaker Fresh Water Amps Inlet Drain Vacuum Max. Width Depth Height Weight Total Size per Connection Model Users (IN.) (IN.) (IN.) (LBS.) HP Voltage Per Hertz Pump Connection Connection Size Pump (Amps) Size(IN.) Size(IN.) (NOM.PIPE) AVB10S 2 13 11 15 70 1 115/230 13/6.5 60 20 3/4 3/4 1/4, 3/8, OR AVB10SR 1/2 AVG10S 13 11 15 72 1 115/230 13/6.5 60 20 3/4 3/4 1/4, 3/8, OR 3 AVG 10S R 1/2 AVU10S 3 13 11 15 74 1 115/230 13/6.5 60 20 3/4 3/4 1/4, 3/8, OR AVU1OSR 1/2 AVB20S 4 13 11 18 83 2 208-230 7 60 20 1 3/4 1/4, 3/8, OR AVB20SR 1/2 AVG20S 5 13 11 18 85 2 208-230 7 60 20 1 3/4 1/4, 3/8, OR AVG20SR 1/2 AVU20S 5 13 11 18 87 2 208-230 7 60 20 1 3/4 1/4, 3/8, OR AVU2OSR 1/2 • www.Midmark.com • 1-800-Midmark•www.Documark.com