Loading...
Specifications F -collo 9//00- 61/x& 5�✓/�1 �La� s Ct /I -Q0121 9z°T- 92Yz if 72.5(- 92j(4, Il it -vo 1'2-3 930q- °13`12 RECEIVED " � p 12 . ' - f 6 13`147 - 93-7(0 H `` c! JUL 31 2012 It( C' 1 �� _ r,r: f�ptJ Western States Ef Fire Protection Co. ptoreztat .dined awe promo a subsidiary of API Group, Inc. Fire Alarm Submittal The Reserve Ashbrook 9160 thru 9346 Mandamus Ct. Tigard, OR WSFP Job #LA0675 AP1 Group, Inc. Table of Contents Section Description A. Fire Alarm Material 1. Fire -lite MS 9050UD fire alarm panel 2. Fire -lite MS -4 4 zone fire alarm panel 3. Firc -litc BC -12 manual pull station 4. Fire -lite SD -355 photo smoke detector 5. Fire -lite MMF -300 monitor module 6. Fire -lite BG-12LX pull station 7. System Sensor 2 -WB photo smoke 8. System Sensor P2RK outdoor horn strobe 9. System sensor P2W /HW /SW horn strobes /horns /strobes Scope of Work Building 4 will have an addressable panel and devices. All other building will have a 4 zone conventional panel that report alarm, trouble, and supervisory via addressable modules and underground wiring to the Building for fire alarm panel for off -site monitoring. IWO Western States Fire Protection Co. Pzoteee 9 4ive4 aid Pu freztq DF- 52418:D • A1-20 Ms- 9050UD(E) FIre•LITe'ALarms Fire Alarm Control Panel with DACT by Honeywell General The Fire•Lite MS- 9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- -•• - -_• sive list of powerful features, the MS- 9050UD programs just like Fire•Lite's larger products, yet fits into applications previously served only by conventional panels. _ The MS- 9050UD's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK -CD Upload/ u• -• •- Download utility. In addition, the control panel may be pro- grammed or interrogated off -site via the public switched tele- phone network. Any personal computer with Windows'" 95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Fire•Lite Upload /Download software kit PK -CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walk -test data, current status and system voltages. • Point trouble identification. The power supply and all electronics are contained on a single • Waterflow selection per module point. — circuit board supported on a new quick install chassis and • Alarm verification selection per detector point. housed in a metal cabinet. Available accessories include local • Maintenance alert warns when smoke detector dust accumu- and remote upload /download software, remote annunciators, lation is excessive. and reverse polarity /city box transmitter. (4XTMF) One - person audible or silent walk test with walk -test log and • New options include a UL listed printer, PRN -6F and the new printout. IPDACT Internet Monitoring module.The Fire Watch Series inter- • System alarm verification selection per detector point. - net monitoring modules IPDACT-2 and IPDACT -2UD permit PAS (Positive Alarm Sequence) and Pre - signal per point • monitoring of alarm signals over the Internet, saving the monthly (NFPA 72 compliant). cost of two telephone lines. Although not required, the second- ary telephone line may be retained providing backup communi- • Up to eight ANN -BUS annunciators cation over the public switched telephone line. • Remote Acknowledge, Alarm Silence, Reset and Drill via NOTE: Unless otherwise specified, the term MS- 9050UD is used addressable modules or remote annunciator. in this data sheet to refer to both the MS- 9050UD and the MS- • Upload /Download (local or remote) of program and data via 905OUDE FACPs. For MS- 905OUDC. refer to DF- 60445. integral DACT. Features SLC COMMUNICATION LOOP • Single addressable SLC loop which meets NFPA Style 4, 6 • Listed to UL Standard 864, 9th edition. and 7 requirements. • Auto - program (learn mode) reduces installation time. • 50 addressable device capacity (any combination of address - Reports two devices set to the same address. able detectors and modules). • On -board DACT. • Compatible with Fire•Lite's addressable devices (refer to SLC • Two independently programmable Style Z (Class A) or Style Wiring Manual). Y (Class B) NAC circuits. • Selectable strobe synchronization for System Sensor, Whee NOTIFICATION APPLIANCE CIRCUITS (NAGS) lock, and Gentex devices. • Two independently programmable output circuits. Circuits • Remote Acknowledge, Silence, Reset and Drill via address- can be configured for the following outputs: able monitor modules. - Style Y (Class B) • Two programmable relays and one fixed trouble relay. - Style Z (Class A) • Built -in Programmer. - Door Holder Service (cannot be used tor notification appliances) • Telephone Line Active LEDs. - Aux Power Source (cannot be used for notification appliances) • EIA -232 PC interface. • Silence Inhibit and Autosilence timer options. • Integral 80- character LCD display with backlighting. • Continuous, March Time, Temporal or California code for • Real -time clock/calendar with automatic daylight savings main circuit board NACs with two -stage capability. - control. • Selectable strobe synchronization per NAC. • History file with 500 event capacity. • 2.5 A total power for NACs. • Automatic detector sensitivity testing (NFPA 72 compliant). NOTE: Maximum or total 24VDC system power shared between • Automatic device type -code verification. all NAC circuits and the ANN -BUS is 2.7 A. DF -52418 D • 02/22/2011 — Page 1 of 4 PROGRAMMING AND SOFTWARE °fit: • Autoprogram (learn mode) reduces installation time. • '1,.1--; • Custom English labels (per point) may be manually entered 9 (p p ) Y Y or selected from an internal library file. • Two programmable Form -C relay outputs. - __ • 20 software zones. • Continuous fire protection during online programming at the front panel. MS- 9050UD • Program Check automatically catches common errors not Fire Alarm linked to any zone or input point. Control Panel • OFFLINE PROGRAMMING: Create the entire program in ANN -80 your office using a Windows® -based software package(order programming kit PK -CD, containing PK -Plus, separately). Upload /download system programming locally. r SD355 Printer User interface Photo Detector Gateway LED INDICATORS ANN -S /PG • AC Power (green) • Fire Alarm (red) 4 � , • Supervisory (yellow) AD355 Graphic LED Module • Trouble (yellow) Adapt Detector ANN -VO • Alarm Silenced signals (yellow) _ — 4P KEYPAD • 16 key alpha- numeric pad H355/H355R/H355HT Relay Module 1 15 • Acknowledge /Step Heat Detector ANN -RLY — P2R • Alarm Silenced Strobe • Drill (Manual Evacuate) Il Reset (lamp test) MDF -300 Product Line Information Dual Monitor Module P2R MS- 9050UD(E): Combination DACT /Fire Alarm Control Panel - Strobe with one SLC loop. Includes main circuit board with display, ' Power Supply chassis with transformer, backbox with door, plastic bag contain- FCPS 24FS6 FCPS -24FS8 ing screws, cables, key, etc., manual. (For MS - 905OUDC, refer SD355T to DF 60445.) Photo/Thermal P2R PK -CD: Contains PK -Plus programming software for Win - g -iiii Strobe dows® -based PC computer (cable not included). DP- 51050: Optional dress panel for the MS- 9050UD. Multi Modules TR -CE: Optional trim ring for semi -flush mounting. MMF -300 • CRF -300 -6 Six -Relay Control Module BB-2F: Optional cabinet for one or two modules. Monitor Module • CMF -300 -6 Six - Circuit Supervised Control Module BB -6F: Optional cabinet for up to six modules mounted on II • MMF -302 -6 Six -Zone Interface Module CHS-6 chassis. • MMF-300-10 Ten -Input Monitor Module BB -26: Battery backbox. holds up to two 25 AH batteries and CHG -75. MMF -302 BB -55F: Battery box, houses two 55 AH batteries 2 -Wire Detector Monitor Module ' CHS-6: Chassis, mounts up to six multi modules in a BB 6F t cabinet. dir _ CHG -75: Battery charger for lead -acid batteries with a rating of 25 to 75 AH. D355PL Beam Detector CHG -120F: Remote battery charging system for lead -acid bat - Duct Detector BEAM- 335/(S) teries with a rating of 55 to 120 AH. Requires additional BB -55F for mounting. FIRE MS- 9050UD BAT Series: Batteries, see data sheet DF- 52397. PRT /PK- CABLE: Cable printer /personal computer interface • ADDRESSABLE FIRE ALARM cable. 1 PRN -6F: UL listed compatible event printer. Uses tractor -fed • BG- 12LXAddressable CONTROL PANEL paper. Manual Pull Station IPDACT, IPDACT -2/2UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether - Page 2 of 4 — DF- 52418:D • 02/22/2011 net internet connection. Requires compatible Teldat Visoralarm 4.0° (10.16 cm.) box. Includes plastic cover plate and end -of -line Central Station Receiver. Can use DHCP or static IP. (See data resistor. Module may be configured for either a Style B (Class B) sheet df -52424 for more information.) or Style D (Class A) IDC. IPBRKT: Mounting kit for IPDACT -2/2UD in common enclosure. MDF -300: Dual Monitor Module. Same as MMF -300 except it IPSPLT: Y adaptor option allows connection of both panel dialer provides two Style B (Class B) only IDCs. outputs to one IPDACT -2 /2UD cable input. MMF -301: Miniature version of MMF -300. Excludes LED and AC- TRMBLK: AC Terminal Block mounts to a metal bracket, in Style D option. Connects with wire pigtails. May mount in device turn, mounts to the FACP chassis. Use AC- TRMBLK when wire backbox. nuts are not allowed for AC connections to the transformer. MMF -302A: Similar to MMF -300A. Addressable Monitor Module OPTIONAL MODULES for one zone of conventional two -wire detectors. Requires reset - table 24 VDC power. Refer to the Device Compatibility Docu- 4XTMF Reverse Polarity Transmitter Module: Provides a ment for listed compatible devices and quantity limitation. supervised output for local energy municipal box transmitter, CMF -300: Addressable Control Module for one Style Y/Z (Class alarm and trouble. Includes a disable switch and disable trouble B /A) zone of supervised polarized Notification Appliances. LED. Mounts directly to a 4.0° (10.16 cm.) electrical box. Notification ANN -SEC: Optional secondary ANN -BUS interface module. Appliance Circuit option requires external 24 VDC to power noti- Note. Used only with firmware 3.0 or higher. fication appliances. COMPATIBLE ANNUNCIATORS CRF -300: Addressable relay module containing two isolated sets of Form -C contacts, which operate as a DPDT switch. ANN- 80( -W): Remote LCD annunciator mimics the information Mounts directly to a 4.0° (10.16 cm.) box, surface mount using displayed on the FACP LCD display Recommended wire type is the SMB500. un- shielded. (Basic model is red; order -W version for white; see BG -12L(: Addressable manual pull station with interface mod - DF- 52417.) ule mounted inside. ANN -I/O: LED Driver Module provides connections to a user 1300: This module isolates the SLC loop from short circuit condi- supplied graphic annunciator. (See DF- 52430.) tions (required for Style 6 or 7 operation). ANN -LED: Annunciator Module provides three LEDs for each SMB500: Used to mount all modules except the MMF -301 and zone: Alarm, Trouble, and Supervisory. Ships with red enclo- M301. sure. (See DF- 60241) MMF- 300 -10: Ten -input monitor module. Mount one or two mod - ANN -REED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF- 60241.) CHS-6 - a chassis i n a cabinet F cabinet. Mount up to six modules on a -6 assis n BB-6F cabnet. ANN -RLY: Relay Module provides 10 programmable Form -C MMF- 302 -6: Six -zone interface module. Mount one or two mod - relays. Can be mounted inside the cabinet. (See DF- 52431.) ules in a BB -2F cabinet (optional). Mount up to six modules on a ANN -S/PG: Serial /Parallel Printer Gateway module provides a CHS -6 chassis in a BB -6F cabinet. • connection for a serial or parallel printer. (See DF- 52429) CMF - 300-6: Six- circuit supervised control module. Mount one or ADDRESSABLE DEVICES two modules in a BB -2F cabinet (optional). Mount up to six mod- All feature a polling LED and rotary switches for addressing. ules on a CHS -6 chassis in a BB -6F cabinet. CP355: CRF- 300 -6: Six -relay control module (Form -C relays). Mount P355: Addressable low- profile ionization smoke detector. one or two modules in a BB -2F cabinet (optional). Mount up to SD355: Addressable low- profile photoelectric smoke detector. six modules on a CHS -6 chassis in a BB -6F cabinet. SD355T: Addressable low- profile photoelectric smoke detector NOTE: For more information on Compatible Addressable Devices with thermal sensor. for use with the MS- 9050UD, see the following data sheets (docu- SD355R: Remote test capable addressable photoelectric ment numbers) AD355 (DF- 52386), BG -12LX (DF- 52013), CMF - smoke detector for use with DNR(W) duct detector housing. 300 -6 (DF- 52365), CRF -300 -6 (DF- 52374), CMF /CRF Series (DF- 52130), CP355 (DF- 52383), H355 Senes (DF- 52385), 1300 (OF- H355: Fast - response, low- profile heat detector. 52389), MMF -300 Senes/MDF -300 (DF- 52121), MMF- 300 -10 H355R: Fast - response, low- profile heat detector with rate -of- (DF- 52347), MMF -302 -6 (DF- 52356), SD355/SD355T (DF- rise option. 52384) H355HT: Fast - response, low- profile heat detector that activates ADDRESSABLE DEVICE ACCESSORIES at 190 °F /88 °C. End -of -Line Resistor Assembly (R-47K and R- 3.9K): The AD355: Low - profile, intelligent, "Adapt" multi- sensor detector 47k ohm assembly supervises the MMF -300, MDF -300, MMF - (B350LP base included). 301, and CMF -300 module circuits. The 3.9k ohm assembly BEAM355: Intelligent beam smoke detector. supervises the MMF -302 module circuit. These resistors are BEAM355S: Intelligent beam smoke detector with integral sen- included with each module. sitivity test. Power Supervision Relay: Supervises the power to 4 -wire D355PL: InnovairFlex low -flow non -relay duct - detector housing; smoke detectors and notification appliances. includes SD355R. DNR: InnovairFlex low -flow non -relay duct - detector housing. Wiring Requirements (Order SD355R separately.) While shielded wire is not required, it is recommended that all • DNRW: InnovairFlex low -flow non -relay duct - detector housing, SLC wiring be twisted -pair to minimize the effects of electrical with NEMA -4 rating. Watertight. (Order SD355R separately.) interference. Refer to the panel manual for wiring details. MMF -300: Addressable Monitor Module for one zone of nor- mally -open dry- contact initiating devices. Mounts in standard • DF- 52418:D • 02/22/2011 — Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity condensing) at 32 °C ± 2 °C (90 °F ± 3 °F). However, the useful life of the system's standby batteries and the electronic compo- • Intelligent Signalling Line Circuits 1 nents may be adversely affected by extreme temperature ranges • Addressable device capacity 50 and humidity. Therefore, it is recommended that this system and • Programmable software zones 20 its peripherals be installed in an environment with a normal room • Annunciators 8 temperature of 15 — 27 °C /60 — 80 °F. Electrical Specifications NFPA Standards AC Power: MS 9050UD 120 VAC, 60 Hz, 3.0 A. MS 9050UDE: The MS- 9050UD(E) complies with the following NFPA 72 Fire 240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG (2.00 mm2) Alarm Systems requirements: with 600 V insulation. Nonpower - limited, supervised. — LOCAL (Automatic, Manual, Waterflow and Sprinkler Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger Supervisory). Capacity: 7 -18 AH (MS- 9050UD cabinet holds maximum of two — AUXILIARY (Automatic, Manual and Waterflow) (requires 18 AH batteries.) 4XTMF). Communication Loop: Supervised and power limited. — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and Notification Appliance Circuits: Terminal Block provides con- supervisory relays may be connected to UL 864 listed nections for two NACs, Style Y (Class B) or Style Z (Class A). transmitters. For reverse polarity signaling of alarm and Special Application power. Power - limited, supervised circuitry. trouble, 4XTMF is required.) Maximum signaling current per circuit: 2.5 A. End -of -Line Resis- — PROPRIETARY (Automatic, Manual and Waterflow). tor: 4.7k ohm, 1/2 watt (P /N 71252 UL listed) for Style Y (Class B) _ CENTRAL STATION (Automatic, Manual and Waterflow, NAC. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. and Sprinkler Supervised). Two Programmable Relays and One Fixed Trouble Relay: — OT, PSDN (Other Technologies, Packet switched Data Net Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC work) (resistive). Form -C relays, nonpower- limited, nonsupervised. Agency Listings and Approvals Cabinet Specifications The listings and approvals below apply to the basic MS- Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" 9050UD(E) control panel. In some cases, certain modules may (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" not be listed by certain approval agencies, or listing may be in (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR -CE): process. Consult factory for latest listing status. 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. • UL: S624 • FM approved - Shipping Specifications • CSFM: 7165- 0075:210 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) • MEA: 442 -06 -E high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. NOTE: See OF for ULC listed model. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32 — 120 °F and at a relative humidity 93% ± 2% RH (non - FireLite® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCREEMNI a MNEfitenur® All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire•Lite Alarms. Phone: (800) 627 -3473, FAX: (877) 699 -4105. www.firelite.com Page 4 of 4 — DF- 52418:D • 02/22/2011 DF- 52266:A2 • A2 -260 MS -4(E) Fire•LITeAtarms • Fire Alarm Control Panel by Honeywell Conventional Fire Alarm Control Panels General The Fire•Lite MS -4 and MS -4E Fire Alarm Control Panels (FACPs) bring the latest in microprocessor technology to con- ventional fire controls. The MS -4 is compatible with the 13TM smoke detectors from System Sensor, with drift compensation, I . maintenance alert, and freeze warning. Automatic synchroniza- tion of audio /visual devices with three selections for manufac- turer protocol. The Notification Appliance Circuit (NAC) protocol 1ik••••.. MS -a can silence audible devices while strobes continue to flash, using a single pair of wires. The MS -4 is compatible with conventional input devices such as =_ two- and four -wire smoke detectors, pull stations, waterflow -. -'? ^ - devices, tamper switches and other normally -open contact devices. Refer to the Fire•Lite Device Compatibility Document for a complete list of compatible devices. Note: Unless indicated otherwise, the term "MS -4 " refers to both MS -4 and MS -4E models. Features • Four Style B (Class B) Initiating Device Circuits (IDCs). • Two Style Y (Class B) NACs. • Optional module that converts all four IDCs and two NACs to Class A operation. • 24 VDC. • i Technology features: – Drift compensation automatically adjusts detector sensitiv- • Silent or audible Walk Test operation mode commanded from ity and increases resistance to false alarms caused by dust the front keypad, with automatic return -to- normal after one accumulation. hour of inactivity. – Maintenance Alert LEDs (per zone) warn of excessive dirt • Each zone may be programmed for supervisory or fire; each - accumulation, preventing false alarms (meets NFPA 72 zone has separate red and yellow LEDs. requirements). • Zone 4 is programmable for combination of tamper supervi- – Detector sensitivity is automatically measured by the sory monitoring and waterflow alarm. • detector, which automatically adjusts its sensitivity back to Form -C Alarm, Trouble, and Supervisory relays. the factory settings when it becomes more sensitive due to • 3.0 A total usable current. • 6.0 A total usable current available with optional second contaminants settling in the chamber. transformer. – Wireless handheld sensitivity meter eliminates the need for • Control buttons: voltmeters, magnets. and a physical connection to the – ACK (Acknowledge) detector. The reader displays sensitivity in terms of percent – Alarm Silence per foot obscuration and provides text status indication. – Reset – Walk Test – Supervisory LED (per zone) provides warning if a detector – Zone Enable /Disable (one per zone) senses temperature approaching freezing. • LED indicators: – Special test protocol and LED indication allows quick test of – Fire Alarm (one per zone) all detectors without need for a ladder. – Supervisory (one per zone) – Trouble (one per zone) • NAC synchronization features: – Maintenance (one per zone) – Synchronization of standard ANSI audible signals as – AC Power required by NFPA 72. – NAC Disable – Synchronization of ADA compliant strobes per NFPA 72. – Zone Disable – Selectable for System Sensor, Wheelock, and Gentex – NAC Fault protocols. – System Trouble – Selective Silence feature for manual silence of horns – Power Trouble while strobes continue to flash on the same NAC. – Walk Test – Alarm verification selectable for each zone. – Alarm Silence – Disable switches provided per zone. – Earth Fault (on circuit board) • NACs programmable for: – Battery Fault (on circuit board) – Silence Inhibit – Charger Fault (on circuit board) – Auto Silence • Piezo sounder for alarm, trouble, supervisory and mainte- – Strobe Synchronization Hance. • – Selective Silence (horn strobe mute) • Optional plug -in 4XTMF transmitter module. – Temporal or Steady signal • Optional plug -in 4XZMF zone relay module. – Silenceable or Nonsilenceable • Optional 4XLMF transmitter module for RZA -4XF remote LED annunciator. • Optional dress panel. DF- 52266:A2 • 06/11/2010 — Page 1 of 2 Operation 2) Total current for nonresettable power, resettable power and Activation of a compatible smoke detector or any normally -open two NACs must not exceed 6.0 A for the MS -4 (required optional • fire alarm initiating device activates audible and visual signaling second transformer). devices, illuminates an indicating LED, sounds the piezo CABINET DIMENSIONS sounder at the FACP, activates the FACP alarm relay and oper- Door: 15.342" (38.97 cm) high x 14.667" (37.28 cm) wide x ates an optional module used to notify a remote station or initi- 0.375" (0.95 cm) deep. ate an auxiliary control function. Backbox: 15.0" (38.10 cm) high x 14.5" (36.83 cm) wide x 3.0" Specifications (7.62 cm) deep. BACKBOX MOUNTING AC POWER - TB3 The cabinet can be surface mounted. The door is removable • MS -4: 120 VAC, 50/60 Hz, 2.3 A. during installation by opening and lifting it off the hinges. The • MS -4E: 240 VAC, 50 Hz, 1.15 A. cabinet mounts using two key slots at the top of the backbox and • Wire Size: Minimum 14 AWG (2.0 mm with 600 V insulation. two additional 0.25" diameter holes at the bottom. BATTERY (SEALED LEAD - ACID ONLY) - J8 • Maximum charging circuit: normal flat charge 27.6 VCD @ Listings and Approvals 0.8 A. • UL Listed: S624 • Maximum battery charger capacity: 18.0 AH battery (two • MEA: 297 -01 -E 7.0 AH batteries can be housed in the FACP cabinet. Larger • CSFM: 7165- 0075:200 batteries require a separate battery box such as the Fire•Lite BB-17F). Ordering Information INITIATING DEVICE CIRCUITS - TB3 MS-4: Four -zone conventional FACP; 120 VAC, 50/60 Hz, 2.3 A. • Alarm zones 1 - 4. MS -4E: Same as above, but 240 VAC, 50 Hz, 1.15 A operation. • Power - limited circuitry. CAC -4: Class A converter module. Used to convert Style B • Operation: all zones Style B (Class B). (Class B) IDC to Style D (Class A) and Style Y (Class B) NAC to • Normal operating voltage: nominal 20 VDC. Style Z (Class A). The module connects to J1 on the MS -4 cir- • Alarm current: 15 mA minimum. cuit board. • Short - circuit current: 40 mA maximum. 4XTMF: Transmitter module. • Maximum loop resistance: 100 ohms. 4XLMF: LED interface module. • End -of -line resistor: 4.7K ohm, 1 /2 watt (P /N 71252). 4XZMF: Zone relay module, 4 form C relay. • Standby current: 4 mA. RZA: -4XF: Remote Annunciator. • Compatible devices: refer to the Fire•Lite Device Compatibil- BB -17F: Battery box, required to house two batteries greater ity Document PN 15384 for a complete list of compatible than 7 AH to a maximum of 18 AH. devices. 411/411UD: Three -input (channels) model 411, and four -input NOTIFICATION APPLIANCE CIRCUITS - TB2 model 411UD, dual - line Digital Alarm Communicator/Transmit - ters (DACTs). Can be used as slave communicators with the • Two NACs. FACP. • Power - limited circuitry. DP- MS2/4: Optional dress panel. • Normal operating voltage: nominal 24 VDC. MS -4RB: Replacement board. • Maximum signalling current: 2.5 A total with standard trans TR - - Optional trim ring for semi - flush mounting. former 5.0 A total (2.5 A maximum per NAC) with optional A 2 -zone version of this panel is also available. See DF- 52211. transformer. • End -of -line resistor: 4.7K ohm, 1 /2 watt (P /N 71252). • Compatible devices: refer to the Fire•Lite Device Compatibil- ity Document PN 15384 for a complete list of compatible devices. FORM - C RELAYS • Trouble Relay TB5 (fail - safe). • Alarm Relay TB6. • Supervisory relay TB7. • Relay contact ratings: 2.0 A @ 30 VAC (resistive). AUXILIARY OUTPUT: RESETTABLE POWER - TB1 • Operating voltage: nominal 24 VDC. • Maximum available current: 500 mA - appropriate for pow- ering four -wire smoke detectors (see notes). • Power limited circuitry. Fire•Lite® Alarms is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use Notes: 1) Refer to the Fire•Lite Device Compatibility Document of this document is strictly prohibited. for a complete list of compatible devices. 1SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. C E R T I F 1 E We cannot cover all specific applications or anticipate all requirements. ONIMEMNI 1MVIllCTI M6 All specifications are subject to change without notice. SUALLTY SYSTEMS Made in the U.S. A. For more information, contact Fire•Lite Alarms. Phone: (800) 627 -3473, FAX: (877) 699 -4105. www.firelite.com Page 2 of 2 - DF-52266:A2 • 06/11/2010 DF- 52004:A1 • F -050 BG-1 2 Series FIYe•LITe-ALarmS Manual Fire Alarm Pull Stations by Honeywell Conventional Initiating Devices • General The Fire-Lite BG -12 Series is a cost - effective, feature - packed series of non -coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and FIRE end -user in mind, The BG -12 Series features a variety of mod- els including single- and dual- action versions. The BG -12 Series provides Fire-Lite Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a man - I PUSH IN I ual alarm initiating input signal. Its innovative design, durable *PULL DOWN • construction, and multiple mounting options make the BG -12 Series simple to install, maintain, and operate. __ I Features • Aesthetically pleasing, highly visible design and color. • Attractive contoured shape and light textured finish. • Meets ADA 5 lb. maximum pull- force. @) Fire•LITe' } & • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Easily operated(single - or dual- action), yet designed to pre- vent false alarms when bumped, shaken, or jarred. • PUSH IN /PULL DOWN handle latches in the down position to clearly indicate the station has been operated. Construction • The word "ACTIVATED" appears on top of the handle in • Cover, backplate and operation handle are all molded of bright yellow, further indicating operation of the station. durable polycarbonate material. • Operation handle features white arrows showing basic opera- • Cover features white lettering and trim. lion direction for non - English- speaking persons. • Red color matches System Sensor's popular SpectrAlert® • Braille text included on finger -hold area of operation handle Advance horn /strobe series. and across top of handle. • Multiple hex- and key -lock models available. Operation - • U.S. patented hex -lock needs only a quarter -turn to lock/ unlock. The BG -12 manual pull stations provide a textured finger -hold • Station can be opened for inspection and maintenance with- area that includes Braille text. In addition to PUSH IN and PULL out initiating an alarm. DOWN text, there are arrows indicating how to operate the sta- • Product ID label viewable by simply opening the cover; label lion, provided for non - English- speaking people. is made of a durable long -life material. Pushing in and then pulling down on the handle activates the • The words "NORMAL" and "ACTIVATED" are molded into the normally -open alarm switch. Once latched in the down position, plastic adjacent to the alarm switch (located inside). the word "ACTIVATED" appears at the top in bright yellow, with a • Four - position terminal strip molded into backplate. portion of the handle protruding at the bottom as a visible flag. • Terminal strip includes Phillips combination -head captive 8/32 Resetting the station is simple: insert the key, twist one quarter - screws for easy connection to Initiating Device Circuit (IDC). turn, then open the station's front cover, causing the spring - loaded operation handle to return to its original position. The • Terminal screws backed -out at factory and shipped ready to alarm switch can then be reset to its normal (non - alarm) position accept field wiring (up to 12 AWG /3.1 mm2). manually (by hand) or by closing the station's front cover, which • Terminal numbers are molded into the backplate, eliminating automatically resets the switch. the need for labels. • Switch contacts are normally open. • Can be surface - mounted (with SB -10 or SB -I /O) or semi - flush mounted. Semi -flush mount to a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box. • Backplate is large enough to overlap a single -gang backbox cutout by 1/2" (1.27 cm). • Optional trim ring (BG12TR). • Spanish versions (FUEGO) available (BG- 12LSP. BG- 12LPSP). • Designed to replace the Fire-Lite legacy BG -10 Series. • Models packaged in attractive, clear plastic (PVC), clam- shell- style, Point -of- Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station. DE- 52004:A1 • 04/22/08 — Page 1 of 2 Specifications Agency Listings and Approvals PHYSICAL SPECIFICATIONS: The listings and approvals below apply to the BG -12 Series pull stations. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult pull station SB -I /O SB -10 factory for latest listing status. - Height 5.5 inches 5.601 inches 5.5 inches • C(UL)US: S711 (13.97 cm) (14.23 cm) (13 97 cm) • FM Approved Width 4.121 inches 4.222 inches 4.121 inche • CSFM: 7160-0075:184 (10.47 cm) (10.72 cm) (10.47 cm) MEA: 67-02-E • Depth 1.39 inches 1 inches 1.375 inches • Patented: U.S. Patent No. D428,351; 6,380,846: 6,314,772: (3 53 cm) (3 66 cm) (3.49 cm) 520344i m.IDI 6,632.108. ELECTRICAL SPECIFICATIONS: Product Line Information Switch contact ratings: gold - plated; rating 0.25 A @ 30 VAC or BG -12S: Single- action pull station with pigtail connections, hex VDC. lock. ENGINEERING /ARCHITECTURAL SPECIFICATIONS BG - 12SL: Same as BG - 12 with key lock. Manual Fire Alarm Stations shall be non -code, with a key- or BG -12: Dual- action pull station with SPST N/O switch, screw hex - operated reset lock in order that they may be tested, and so terminal connections, hex lock. designed that after actual Emergency Operation, they cannot be BG -12L: Same as BG -12 with key lock. restored to normal except by use of a key or hex. An operated BG- 12LSP: Same as BG -12L with English /Spanish (FIRE/ station shall automatically condition itself so as to be visually FUEGO) labeling. detected as activated. Manual stations shall be constructed of BG- 12LOB: Same as BG -12L with "outdoor use" listing. red colored LEXAN (or polycarbonate equivalent) with clearly Includes outdoor listed backbox, and sealing gasket. visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, BG -12LO: Same as BG -12L with "outdoor use" listing. Does 1.00 inches (2.54 cm) or larger. Stations shall be suitable for not include backbox. surface mounting on matching backbox SB -10 or SB -I /O; or BG -12LA: Same as BG -12L with auxiliary contacts. semi -flush mounting on a standard single -gang, double -gang, or BG- 12LPS: Dual- action pull station with pre - signal option. — 4" (10.16 cm) square electrical box, and shall be installed within BG- 12LPSP: Same as BG -12LPS with English /Spanish (FIRE/ the limits defined by the Americans with Disabilities Act (ADA) or FUEGO) labeling. per national /local requirements. Manual Stations shall be Under- writers Laboratories listed. SB -10: Surface -mount backbox, metal. NOTE: The words "FIRE /FUEGO" on the BG -12LSP shall appear SB-I/O: Surface mount backbox, plastic. (Included with BG - on the front of the station in white letters. approximately 3/4" 12L08.) (1.905 cm) high. BG12TR: Optional trim ring for semi -flush mounting. 17003: Keys, set of two. (Included with key -lock pull stations.) . • 17007: Hex lock, 9/64 ". (Included with hex -lock pull stations.) 4 NOTE: For addressable BG -12LX models. see data sheet DF- 52013. FUEGO/FIRE 1 EME Y PUSH PUJ IN 1 HALE HAM ARAJO PULL DOWN 8 nre•IITe to • Fire•Lite® Alarms, SpectrAlert® Advance, and System Sensor® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 1S0 9001 This document is not intended to be used for installation purposes. • We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. DMINEBINO I MNIIFACDRING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire•Lite Alarms. Phone: (800) 627 -3473, FAX: (877) 699 -4105. www.firelite.com Page 2 of 2 — DF- 52004:A1 • 04/22/08 SD355(A), SD355T(A), df -52384 b • E -160 SD355R(A) FIre•LrreAtarmS Addressable Photoelectric by Honeywell Smoke Detectors Addressable Devices General The SD355(A) and SD355T(A) addressable, low- profile plug - in photoelectric detectors use a state -of- the -art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's Address- able Fire Alarm Control Panels (FACPs). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135 °F (57 °C). Since these detectors are addressable, they will help , emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annun- ciator capability is available as an optional accessory (P /N RA100Z(A)). The SD355R is a remote test capable detector SD355 with B350LP base for use with D355PL or DNR(W) duct smoke detector hous ings. Features SLC loop: • Two -wire loop connection. • Unit uses base for wiring. Addressing: • Addressable by device. • Direct Decade entry of address: 01 – 99 with MS -9200 - series, and 01 – 159 with MS -9600 series. Architecture: • Unique single- source, dual- chamber design to respond SD355T with B350LP base - quickly and dependably to a broad range of fires. • Sleek, low- profile design. • Integral communications and built -in type identification. Applications • Built -in tamper- resistant feature. Use photoelectric detectors in life- safety applications to pro- • Removable cover and insect - resistant screen for simple vide a broad range of fire - sensing capability, especially where field cleaning. smoldering fires are anticipated. Ionization detectors are often Operation: better than photoelectric detectors at sensing fast, flaming fires. • Withstands air velocities up to 4,000 feet -per- minute (20 m/ sec.) without triggering a false alarm. Construction • Factory preset at 1.5 °o nominal sensitivity for panel alarm These detectors are constructed of off -white LEXAN ®. threshold level. SD355(T) plug -in, low- profile smoke detectors are designed to • Visible LED 'blinks" when the unit is addressed (communi- commercial standards and offer an attractive appearance. cating with the fire panel) and latches on in alarm. Mechanicals: Installation • Sealed against back pressure. SD355(T) plug -in detectors use a detachable mounting base • Direct surface mounting or electrical box mounting. to simplify installation, service and maintenance. Mount base • Mounts to: single -gang box, 3.5" (8.89 cm) or 4.0" (10.16 on box which is at least 1.5 inches (3.81 cm) deep. Suitable cm) octagonal box, or 4.0" (10.16 cm) square electrical box boxes include: (using a plaster ring — included). • 4.0" (10.16 cm) square box with plaster ring. Other system features: • 4.0" (10.16 cm) octagonal box. • Fully coated circuit boards and superior RF /transient pro- • 3.5' (8.89 cm) octagonal box. tection. • Single -gang box. • 94 -VO plastic flammability rating. NOTE: Because of the inherent supervision provided by the SLC • Low standby current. loop, end -of -line resistors are not required. Wiring "T- taps" or Options: branches are permitted for Style 4 (Class B) wiring. SD355R mounts in a D355PL or DNR(W) duct detector housing. • Remote LED output connection (P /N RA100Z). df- 52384:b • 3/12/10 — Page 1 of 2 Operation Product Line Information Each SD355/1/R uses one of 99 possible addresses on the NOTE: "A " suffix indicates ULC- Listed model. MS -9200 series and up to 318 (159 on each loop) on the MS- SD355: Adressable photoelectric detector; B350LP base 9600 series Signaling Line Circuit (SLC). It responds to regular included. polls from the system and reports its type and status. SD355A: Sames as SD355 with ULC Listing (B350LPA base The SD3551T /R addressable photoelectric sensor's unique included). unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to SD355T: Same as SD355 but with thermal element; B350LP 4,000 feet -per- minute (20 m /sec.) without sending an alarm base included. level signal. Because of its unipolar chamber, the SD355/T /R SD355TA: Same as SD355T with ULC Listing (B350LPA base is approximately two times more responsive than most photo- included). electric sensors. This makes it a more stable detector. SD355R: Remote test capable addressable photoelectric Detector Sensitivity Test detector for use with a D355PL or DNR(W) duct detector hous- 9. Each detector can have its sensitivity tested (required per B350LP(A): Plug -in detector base. Dimensions: 6.1" (15.5 NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) cm). Mounting: 4.0" (10.16 cm) square box with or without when installed /connected to a MS -9200 series or MS -9600 plaster ring, 4.0" (10.16 cm) octagonal box, 3.5' (8.89 cm) series addressable fire alarm control panel. The results of the octagonal box, or single -gang box. All mounting boxes have a sensitivity test can be printed off the MS -9200 series or MS- minimum depth of 1.5" (3.81 cm). 9600 series for record keeping. B224RB(A): Plug -in System Sensor relay detector base. Specification Diameter: 6.2" (15.75 cm). Mounting: 4.0' (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, Voltage range: 15 - 32 VDC (peak). or 3.5" (8.89 cm) octagonal box. All mounting boxes have a Standby current: 300 pA © 24 VDC. minimum depth of 1.5" (3.81 cm). LED current: 6.5 mA 24 VDC (latched "ON "). B224BI(A): Plug -in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF- 52389). Air velocity: 4,000 ft. /min. (20 m /sec.) maximum. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square Diameter: 6.1' (15.5 cm) installed in B350LP base. box with or without plaster ring, 4.0' (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a Height: 2.1' (5.33 cm) installed in B350LP base. minimum depth of 1.5" (3.81 cm). Weight: 3.6 oz. (102 g). B200SR: Sounder base capable of producing temporal -3 or Operating temperature range: for SD355(A): 0 °C to 49 °C steady sound output. (32 °F to 120 °F); for SD355T(A): 0 °C to 38 °C (32 °F to 100 °F). ACCESSORIES: SD355R(A): installed in a DNR(W) -20 °C to 70 °C ( -4 °F to 158 °F). RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to Temperature: 0 °C - 49 °C (32 °F - 120 °F). a U.S. single -gang electrical box. For use with 8501(A) and 8350LP(A) bases only. Relative humidity: 10% - 93 %, non condensing. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501(A) base only. Listings RMK400: Recessed mounting kit. For use with 8501(A) base Listings and approvals below apply to the SD355(A) and only. SD355T(A) detectors. In some cases, certain modules may MO2 -04 -0O:Test magnet. not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. MO2 -09 -00: Test magnet with telescoping handle. • UL Listed, file S1059. XR2B: Detector removal tool. Allows installation and /or removal • ULC Listed, file S1059. of detector heads from bases in high ceiling applications. • CSFM approved: file 7272 - 0075:194. XP -4: Extension pole for XR2B. Comes in three 5 -foot (1.524 • MEA approved: file 243 -02 -E. m) sections. • FM approved. T55- 127- 010:Detector removal tool without pole. BCK -200B: Black detector covers, box of 10 . WCK -200B: White detector covers, box of 10 . FlashScan® registered trademark of Honeywell International Inc. Bay - blend® is a registered trademark of Bayer Corporation. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. BMCIMHI S & kW/ACHIIM All specifications are subject to change without notice. !MITT SYSTEMS For more information, contact Fire•Lite Alarms. Phone: (800) 627 -3473, FAX: (877) 699 -4105. www.firelite.com Page 2 of 2 - df- 52384:b • 3/12/10 DF- 52121:C • E -325 MMF 300(A) Series Flre•Lrre +Alarms MDF- 300(A) by Honeywell Addressable Monitor Modules y y General Four different monitor modules are available for Fire•Lite's - intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry- contact input • devices, such as conventional heat detectors and pull stations, , or monitor and power a circuit of two -wire smoke detectors - "" (MMF- 302(A)). _ MMF- 300(A) is a standard -sized module (typically mounts to a " "" 4" [10.16 cmj square box) that supervises either a Style D . ° µ° n (Class A) or Style B (Class B) circuit of dry- contact input • "�' _ devices. �• MMF- 301(A) is a miniature monitor module a mere 1.3' (3.302 .11111. Y "� cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D used to super- •', TY.° //* vise a Style B (Class B) circuit of dry- contact input devices. Its �►�/ compact design allows the MMF- 301(A) to be mounted in a single -gang box behind the device it monitors. MMF- 302(A) is a standard -sized module used to monitor and • supervise compatible two -wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF- 300(A) is a standard -sized dual monitor module used to MMF- 300(A) (Type H) monitor and supervise two independent two -wire Style B (Class B) dry- contact initiating device circuits (IDCs) at two may be wired as an NFPA Style B (Class B) or Style D (Class separate, consecutive addresses in intelligent, two -wire systems. A) Initiating Device Circuit. A 47K ohm End -of -Line Resistor LiteSpeedTm is a communication protocol developed by (provided) terminates the Style B circuit. No resistor is Fire•Lite Engineering that greatly enhances the speed of corn- required for supervision of the Style D circuit. munication between analog intelligent devices. Intelligent MMF- 300(A) OPERATION devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU Each MMF- 300(A) uses one of the available module stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from net effect is response speed greater than five times that of the control panel and reports its type and the status (open /nor- other designs. designs. mal /short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control MMF- 300(A) Monitor Module panel. The LED latches steady on alarm (subject to current limitations on the loop). • Built -in type identification automatically identifies this device as a monitor module to the control panel. MMF- 300(A) SPECIFICATIONS • Powered directly by two -wire SLC loop. No additional power Nominal operating voltage: 15 to 32 VDC. required. Maximum current draw: 5.0 mA (LED on). • High noise (EMF /RFI) immunity. Average operating current: 350 pA (LED flashing), 1 com- • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds, 47k EOL. • Direct -dial entry of address: 01 — 159 on MS -9600 series Maximum IDC wiring resistance: 40 ohms. panels, 01 — 99 on other compatible systems. LED flashes during normal operation and latches on steady EOL resistance: 47K ohms. • to indicate alarm. Temperature range: 32 °F to 120 °F (0 °C to 49 °C). The MMF- 300(A) Monitor Module is intended for use in intelli- Humidity range: 10% to 93% noncondensing. gent, two -wire systems, where the individual address of each Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x module is selected using the built -in rotary switches. It pro- 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x vides either a two -wire or four -wire fault - tolerant Initiating 2.125" (5.398 cm) deep box. Device Circuit (IDC) for normally- open- contact fire alarm and supervisory devices. The module has a panel - controlled LED indicator. The MMF- 300(A) can be used to replace M300(A) - modules in existing systems. MMF- 300(A) APPLICATIONS Use to monitor a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally - open dry- contact alarm activation devices. May also be used to monitor normally -open supervisory devices with special supervisory indication at the control panel. Monitored circuit DF- 52121:C • 10/06/2010 — Page 1 of 4 1 MMF- 301(A) Mini Monitor Module Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm) wide x Built -in type identification automatically identifies this device 0.65' (1.651 cm) deep. • as a monitor module to the panel. Wire length: 6' (15.24 cm) minimum. • Powered directly by two -wire SLC loop. No additional power required. MMF- 302(A) Interface Module . • High noise (EMF /RFI) immunity. • Supports compatible two -wire smoke detectors. • Tinned, stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct -dial entry of address: 01 — 159 on MS -9600 series source. panels, 01 — 99 on other compatible systems • High noise (EMF /RFI) immunity. • SEMS screws with clamping plates for ease of wiring. 1415 0 1 ADDR SS 0 1 • Direct -dial entry of address: 01 — 159 on MS -9600 series ° 13 2 2 panels, 01 — 99 on other compatible systems 3 �� �� 4 LOOP �� 4 • LED flashes during normal operation. • LED latches steady to indicate alarm on command from 10 5 5 control panel 9 TENS 9 ONES 6 The MMF- 302(A) Interface Module is intended for use in intelli- 6 n In gent, addressable systems, where the individual address of each module is selected using built -in rotary switches. This module allows intelligent panels to interface and monitor two - 3 I 1- wire conventional smoke detectors. It transmits the status (nor - Y mal, open, or alarm) of one full zone of conventional detectors W U back to the control panel. All two -wire detectors being moni- W 4 0 cc m tored must be UL compatible with the module. The MMF - j 302(A) can be used to replace M302(A) modules in existing 1' systems. 'y I I MMF -302 (A) APPLICATIONS I Use the MMF- 302(A) to monitor a zone of two -wire smoke The MMF- 301(A) Mini Monitor Module can be installed in a detectors The monitored circuit may be wired as an NFPA single -gang junction directly behind the monitored unit. Its Style B (Class B) or Style D (Class A) Initiating Device Circuit. small size and light weight allow it to be installed without rigid A 3.9 K ohm End-of -Line Resistor (provided) terminates the mounting. The MMF- 301(A) is intended for use in intelligent, end of the Style B or D (class B or A) circuit (maximum IDC - two -wire systems where the individual address of each module loop resistance is 25 ohms). Install ELR across terminals 8 is selected using rotary switches. It provides a two -wire initiat- and 9 for Style D application. ing device circuit for normally -open- contact fire alarm devices. The MMF- 301(A) can be used to replace M301(A) modules in MMF- 302(A) OPERATION - existing systems. Each MMF- 302(A) uses one of the available module MMF- 301(A) APPLICATIONS addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open /nor- Use to monitor a single device or a zone of four -wire smoke mal /short) of its Initiating Device Circuit (IDC) A flashing LED detectors, manual fire alarm pull stations, waterflow devices, or indicates that the module is in communication with the control other normally -open dry- contact devices. May also be used to panel. The LED latches steady on alarm (subject to current monitor normally -open supervisory devices with special super- limitations on the loop). visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. MMF- 302(A) SPECIFICATIONS A 47K ohm End -of -Line Resistor (provided) terminates the cir- Nominal operating voltage: 15 to 32 VDC. cuit. Maximum current draw: 5.1 mA (LED on) MMF- 301(A) OPERATION Maximum IDC wiring resistance: 25 ohms. Each MMF- 301(A) uses one of the available module Average operating current: 300 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds, 3 9k eol. the control panel and reports its type and the status (open /nor- mal /short) of its Initiating Device Circuit (IDC) EOL resistance: 3.9K ohms. MMF- 301(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms Nominal operating voltage' 15 to 32 VDC. maximum. Current: 90 mA per module maximum. Average operating current: 350 NA, 1 communication every Temperature range: 32 °F to 120 °F (0 °C to 49 °C). 5 seconds, 47k EOL; 600 pA Max (Communicating, IDC Humidity range: 10% to 93% noncondensing. Shorted). Maximum IDC wiring resistance: 40 ohms. Dimensions: 4.5' (11.43 cm) high x 4' (10.16 cm) wide x - 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x Maximum IDC Voltage: 11 Volts. 2.125° (5.398 cm) deep box. Maximum IDC Current: 400 pA. - EOL resistance: 47K ohms. Temperature range: 32 °F to 120 °F (0 °C to 49 °C). Humidity range: 10% to 93% noncondensing. Page 2 of 4 — DF -52121 C • 10/06/2010 MDF- 300(A) Dual Monitor Module Product Line Information The MDF- 300(A) Dual Monitor Module is intended for use in NOTE: "A" suffix indicates ULC listed model. intelligent, two -wire systems It provides two independent two- MMF- 300(A): Monitor module. wire initiating device circuits (IDCs) at two separate, consecutive addresses It is capable of monitoring normally open contact fire MMF- 301(A): Monitor module, miniature. alarm and supervisory devices. The module has a single panel- MMF- 302(A): Monitor module, two -wire detectors. controlled LED. NOTE: The MDF 300(A) provides two Style B (Class B) IDC cir MDF- 300(A): Monitor module, dual, two independent Class B circuits. cults ONLY. Style D (Class A) IDC circuits are NOT supported in any application. SMB500: Optional surface - mount backbox MDF 300(A) SPECIFICATIONS NOTE: See installation instructions and refer to the SLC Winng Manual, PN 51309. Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Architects' /Engineers' Specifications Average operating current: 750 pA (LED flashing). Specifications of these devices and all FireLite products are Maximum IDC wiring resistance: 1,500 ohms. available from FireLite. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120 °F (0° to 49 °C). Humidity range: 10% to 93% (non- condensing). Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 2.125° (5.398 cm) deep. MDF- 300(A) AUTOMATIC ADDRESSING The MDF- 300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF- 300(A) is set to address "26 ", then it will automati- cally assign itself to addresses "26" and "27 ". NOTE: "Ones" addresses on the MDF- 300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Q CAUTION: Avoid duplicating addresses on the system. Installation MMF- 300(A), MMF- 302(A), and MDF- 300(A) modules mount directly to a standard 4° (10.16 cm) square, 2.125° (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface -mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations These modules are intended for power - limited wiring only. The MMF- 301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424 • ULC: S2424 • FM Approved • CSFM: 7300- 0075:0185 • MEA: 72-01-E DF- 52121:C • 10/06/2010 — Page 3 of 4 Fire.Lite® and LiteSpeed® are registered trademarks and FireWatch is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. ■ ENCINEEIrd & MAHIFACT1RI?YC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire•Lite Alarms. Phone: (800) 627 -3473, FAX: (877) 699 -4105. www.firelite.com Page 4 of 4 — DF- 52121.0 • 10/06/2010 DF- 52013:C1 • E -100 BG -12LX Flre•LITeALarms Addressable Manual Pull Station by Honeywell Addressable Devices General The Fire•Lite BG -12LX is a state -of- the -art, dual- action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire.Lite's addressable fire alarm control panels (FACPs) FIRE Because the BG -12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. • Features I PUSH IN • Maintenance personnel can open station for inspection and PULL D OW N address setting without causing an alarm condition. • Built -in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire -ready for easy connection to ® Fire uTeRmarms SLC loop (accepts up to 12 AWG /3.25 mm wire). by Honeywell • Can be surface mounted (with SB -10 or SB -I /O) or semi - flush mounted. Semi -flush mount to a standard single- 0 a gang, double -gang, or 4" (10.16 cm) square electrical box. • Smooth dual- action design. • Meets ADAAG controls and operating mechanisms guide- LL lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. usually needed for semi -flush mounting with 4" (10.16 cm) or • Attractive shape and textured finish. double -gang boxes (not with single -gang boxes). • Key reset. Operation • Includes Braille text on station handle. • Optional trim ring (BG12TR). Pushing in, then pulling down on the handle causes it to latch in the down /activated position. Once latched, the word "ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the Construction key and pull the door open. This action resets the handle; clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch. Two rotary decimal switches allow address settings (1 — 159 with Breakaway Tab removed for MS -9600 Series, 1 — • Shipping Weight: 9.6 oz. (272.15 g) 99 and MS- 9200UDLS, 1 — 50 for MS- 9050UD). • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VDC. Architectural /Engineering • Maximum SLC loop current: 230 NA. Specifications • Temperature Range: 32 °F to 120 °F (0 °C to 49 °C) Manual Fire Alarm Stations shall be non - coded, with a key- • Relative Humidity: 10% to 93% (noncondensing) operated reset lock in order that they may be tested, and so • For use indoors in a dry location designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- Installation tion shall automatically condition itself so as to be visually - detected as activated. Manual stations shall be constructed of The BG -12LX will mount semi -flush into a single -gang, double- red - colored polycarbonate material with clearly visible operat- gang, or standard 4' (10.16 cm) square electrical outlet box, or ing instructions provided on the cover. The word FIRE shall will surface mount to the model SB -10 or SB -I /O surface back- appear on the front of the stations in white letters, 1.00 inches box. If the BG -12LX is being semi -flush mounted, then the (2.54 cm) or larger. Stations shall be suitable for surface optional trim ring (BG12TR) may be used. The BG12TR is mounting on matching backbox SB -10 or SB -I /O; or semi -flush mounting on a standard single -gang, double -gang, or 4' (10.16 cm) square electrical box, and shall be installed within DF- 52013:C1 •8/16/10 — Page 1 of 2 the limits defined by the Americans with Disabilities Act (ADA) Agency Listings and Approvals or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro - Manual stations shall connect with two wires to one of the con- cess. Consult factory for latest listing status. trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the ▪ UL Listed: S711 state of the manual switch. Manual stations shall provide • MEA: 67-02-E address setting by use of rotary decimal switches. • CSFM: 7150 - 0075:0184 • FDNY: Product Line Information • FM Approved BG -12LX: Dual- action addressable pull station. Includes key Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; locking feature. 6,632,108. SB -10: Surface backbox; metal. SB -I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Fire-Lite is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. IS O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. C R - r 1 F • E U We cannot cover all specific applications or anticipate all requirements. MIMI% i MMIUSTIONS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire•Lite Alarms. Phone: (800) 627 -3473, FAX: (877) 699 -4105. www.firelite.com Page 2 of 2 — DF- 52013:C1 • 8/16/10 SYSTEM SENSOR' Photoelectric Smoke Detectors System Sensor i series smoke detectors represent significant advancement in conventional detection. 3 The i family is founded on three principles: installation ease, intelligence, and instant inspection. Features Installation ease. The i line redefines installation ease with its • Plug in detector line, mounting base included plug -in design.This allows an installer to pre -wire bases (included with heads). The large wire entry port and in -line terminals provide • Large wire entry port ample room for neatly routing the wiring inside the base.The base • In -line terminals with SEMS screws accommodates a variety of back box mounting methods as well as • Mounts to octagonal and single -gang back boxes, 4- square back direct mounting with drywall anchors. To complete the installation, i boxes, or direct to ceiling heads plug into the base with a simple Stop -Drop 'N Lock action. • Stop -Drop 'N Lock attachment to base Intalligonu. P detectors offer a number of intelligent features • Removable detector cover and chamber to simplify testing and maintenance. Drift compensation and • Built-in remote maintenance signaling smoothing algorithms are standard with the i line to minimize nuisance alarms. 2 -wire i detectors can generate a remote LED- • Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W -MOD2 • Simplified sensitivity measurement loop test /maintenance module or a panel equipped with the P • Wide-angle, dual color LED indication protocol.The SENS -RDR, a wireless device, displays the sensitivityof i detectors in terms of percent -per -foot obscuration. • Loop testing via EZ Walk feature • Built -in test switch Instant inspection.The P series provides wide -angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of- sensitivity, alarm, or freeze trouble. When connected to the 2W -MOD2 loop test /maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2 -wire i detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings t ) AIEA MSFM LISTED Ap 1 approved approved I us �:ii 3011446 7272- 1653:152 290-01-8 2093 3180932 rh Smoke Detector Specifications Architectural/Engineering Specifications 9 9 p Smoke detector shall be a System Sensor i Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W -B, 4W -B) or a combination photoelectric/thermal (Model 2WT-B, 4WT -B) with thermal sensor rated at 135 °F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4 -inch octagonal, single -gang, and 4 -inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre- wiring of the base and the head shall be a plug -in type. The detector shall have a nominal sensitivity of 2.5 percent -per -foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual - color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WF-B) conditions. When used in conjunction with the 2W -MOD2 module, 2 -wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non - polarized Minimum: 85V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2 -wire: 50 pA maximum average; 4 -wire: 50 pA maximum average Maximum Alarm Current 2 -wire: 130 mA limited by control panel; 4 -wire: 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2-wire: 100 NA; 4 -wire: n/a Alarm Contact Ratings 2 -wire: n/a; 4 -wire: 0.5 A @ 30V AC/DC Physical Specifications Dimensions (including base) 53 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 63 oz (178 g) Operating Temperature Range 2W -B and 4W -B: 32 °F to 120°F (0 °C to 49°C); 2WT-B and 4WT-B: 32 °F to 100 °F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing — Thermal Sensor 135 °F (57.2 °C) fixed Freeze Trouble 2WT -B and 4WT-B only:41 °F (5 °C) Sensitivity 2.596/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4 -inch octagonal back box Single -gang back box 4 -inch square back box with a plaster ring Direct mount to ceiling LED Modes Power -Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W -B No 2 -wire 130 mA max. limited by control panel 2WT -B Yes 2 -wire 130 mA max. limited by control panel 4W -B No 4 -wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4 -wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W -MOD2 2 -wire loop test / maintenance module RT Removal / replacement tool SENS -RDR Sensitivity reader A77 -AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter _ SYSTEM ®7009 System Sensor 3825 Ohio Avenue • St. Charles, IL60174 Product specifications ubjecttochangewithoutnotice .Visitsystensensa.comfor �$ SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 current product information. od w"° the latest version °`mb data sheet. A05 -0318-007.6/09 • 02169 SYSTEM SENSOR p F Outdoor Selectable- , R Output Horns, Strobes, E -- ' ' and Horn Strobes SpectrAlert®Advance outdoor selectable- output horns, strobes, and horn strobes are rich with features that cut installation times and maximize profits. SPECTRANert Features The SpectrAlert Advance series offers the broadest line of • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 outdoor horns, strobes, and horn strobes in the industry. With candela white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can meet • Field- selectable candela settings on wall and ceiling units: 15, 15/75, virtually any application requirement. 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Plug -in design with minimal intrusion into the back box SpectrAlert Advance outdoor horns, strobes, and horn strobes can •Tamper- resistant construction be used indoors or outdoors in wet or dry applications, and can • Universal mounting plate for wall- and ceiling -mount units provide reliable operation from -40 °F to 151 °F. • Mounting plate shorting spring tests wiring continuity before Like the entire SpectrAlert Advance product line, these devices devices are installed include a variety of features that increase their application versatility • Weatherproof per NEMA 4X, IP56 while simplifying installation. All devices feature plug -in designs with • Listed to UL 1638 (strobe) and UL 464 (horn) minimal intrusion into the back box, which make installations fast • Rated from -40 °F to 151 °F and foolproof while virtually eliminating costly and time - consuming • Horn rated at 88+ dBA at 16 volts ground faults. • Rotary switch for horn tone and three volume selections All horns, strobes, and horn strobes use a universal mounting plate • Compatible with System Sensor synchronization protocol and with an onboard shorting spring that tests wiring continuity before legacy SpectrAlert products the device is installed, protecting devices from damage. In addition, field - selectable candela settings, automatic selection of 12- or 24- volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings T (`04 0 ,� 7300- 1653:187 (outdoor strobes) 55011 (chimes. ho strobes, hams) Y/IIWIp approved 7125 - 1653:188 (horn strobes. chime st robes ) S3593 (outdoor and alert strobes) 3023572 MEA452 -05 -E 7135 - 1653.189 (horns chimes) SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect /Engineer Specifications General SpectrAlert Advance outdoor horns, strobes and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24- volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern.These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical /Electrical Specifications Operating Temperature -40 °F to 151°F ( -40 °C to 66 °C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range' 8 to 175 V (12V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8 x 2.5" high (173 mm diameter x 64 mm high) Wall -Mount Dimensions (including lens) 5.6'1 x 4.7 "W x 25" D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6 "L x 4.7"W x 13 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (5A -WBB) 5.7" L x 5.1"W x 2.0"D (145 mm L x 130 mmW x 51 mm D) Ceiling -Mount Weatherproof Back Box Dimensions (SA -WBBC) 7.1 "diameter x 2.0" high (180 mm diameter x 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0456-002 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8 -17.5 Volts 16 -33 Volts 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non - Temporal High 57 56 69 75 95 NA NA 181 176 Non - Temporal Medium 42 50 60 69 110 NA NA 202 195 Non - Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15 -115 cd) 8 -17.5 Volts 16 -33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 . Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 . Non - Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, High Candela Range (135 -185 cd) 16-33 Volts 16 -33 Volts DC Input 135 150 177 185 FWRlnput 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - Temporal High 255 270 303 309 Non - Temporal High 233 248 275 281 Non - Temporal Medium 242 259 293 299 Non - Temporal Medium 219 232 262 267 Non - Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela Horn and Horn Strobe Output(dBA) ratings must be reduced in accordance with this table. 8 -17.5 16-33 24 -Volt Nominal Strobe Output (cd) Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at 40 °F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32 °F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non - Temporal High 82 82 88 88 93 92 100 100 95 70 5 Non - Temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non - Temporal Low 75 75 81 81 88 84 96 92 115 115 7' Coded High 82 82 88 88 93 92 101 101 135 135 8' Coded Medium 78 78 85 85 90 90 97 98 150 150 9' Coded Low 75 75 81 81 88 85 96 92 177 177 'Settings 7, 8, and 9 are not available on 2 -wire horn strobe. 185 185 /05- 045600: SpectrAlert Advance Dimensions - 4.7" 2.5" 6.8" _ II •° II Dla 1si o1 i %� I 56" Il" �� Wall -mount horn strobes Ceiling -mount horn strobes Al 7.1' 2.0" Dia. i d ° O 2.� ® 5.7" ----: -----Ai■ N ,,, _.----- Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information - Model Description Model Description Wall Horn Strobes Ceiling Horn Strobes P2RK "t 2 -Wire Horn Strobe, Standard cd, Red, Outdoor PC2RK 2 -Wire Horn Strobe, Standard cd, Red, Outdoor P2RHK "t 2 -Wire Horn Strobe, High cd, Red, Outdoor PC2RHK 2 -Wire Horn Strobe, High cd, Red, Outdoor P2WK "t 2 -Wire Horn Strobe, Standard cd, White, Outdoor PC2WK 2 -Wire, Horn Strobe, Standard cd, White, Outdoor P2WHK "t 2 -Wire Horn Strobe, High cd, White, Outdoor PC2WHK 2 -Wire, Horn Strobe High cd, White, Outdoor - P4RKt 4 -Wire Horn Strobe, Standard cd, Red, Outdoor PC4WK 4 -Wire, Horn Strobe, Standard cd, White, Outdoor P4WK 4 -Wire Horn Strobe, Standard cd, White, Outdoor PC4WHK 4 -Wire, Horn Strobe, High cd, White, Outdoor P2RHK -120 2 -Wire Horn Strobe, High cd, Red, Outdoor, 120V Ceiling Strobes Wall Strobes SCRK Strobe, Standard cd, Red, Outdoor SRK "t Strobe, Standard cd, Red, Outdoor SCRHK Strobe, High cd, Red, Outdoor SRHK "t Strobe, High cd, Red, Outdoor SCWK Strobe, Standard cd, White, Outdoor SWK "t Strobe, Standard cd, White, Outdoor SCWHK Strobe, High cd, White, Outdoor SWHK "t Strobe, High cd, White, Outdoor Homs HRK Horn, Red, Outdoor Notes: " Add -P'to model number for plain housing (no'FIRP marking on cover), e.g. P2RK -P. t Add " -R "to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. 'Standard rd" refers to strohes that include 1c. 15/75, .0. 75, 95. 110. and 115 candela settings_ "High cd° refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 02009 System Sensor. ✓/ 3825 Ohio Avenue • St. Charles, IL 60174 Product atans,bectto change without notice. Visit systemsensor.comfct _ SENSOR' Phone: 800 -SEN SOR2 • Fax: 630- 377 -6495 anent product information, including the latest Version of this data sheet. A05-0456-002. 11/09.4,2255 *Th_ SYSTEM SENSOR ,‘-e4 Selectable Output Horns, Strobes, and Horn Strobes E E SpectrAlert' Advance selectable- output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTRAIert Features The SpectrAlert Advance series offers the most versatile and • Plug -in design with minimal intrusion into the back box easy -to -use line of horns, strobes, and horn strobes in the industry. •Tamper-resistant construction With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 meet virtually any application requirement. candela • Field- selectable candela settings on wall and ceiling units: 15, 15/75, Like the entire SpectrAlert Advance product line, horns, strobes, 30, 75, 95, 110, 115, 135, 150, 177, and 185 and horn strobes include a variety of features that increase their • Horn rated at 88+ dBA at 16 volts application versatility while simplifying installation. All devices • Rotary switch for horn tone and three volume selections feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually • Universal mounting plate for wall and ceiling units eliminating costly and time - consuming ground faults. Furthermore, • Mounting plate shorting spring checks wiring continuity before a universal mounting plate with an onboard shorting spring tests device installation wiring continuity before the device is installed, protecting devices • Electrically compatible with existing SpectrAlert products from damage. ▪ Compatible with MDL sync module In addition, field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings ao�uu■a � � 0 MEA approved 7125 1653:186 (inaoo str obes ) LISTED APPROVED PP 7125- 1653:1888,om strobes. 54011 (chimes, ho,,, strobes, hors) .. ., chime strobes) 55512 (strobes) 7135 - 1653:189 p,oms, chimes) SpectrAlert Advance Specifications Architect /Engineer Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box, or double -gang back box.Two -wire products shall also mount to a single -gang 2 x 4 x 1 /a -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync .Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync •ircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 175 volts; 24- volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync •ircuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 x 4 x 21 -inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical /Electrical Specifications Standard Operating Temperature 32 °F to 120 °F (0°C to 49 °C) Humidity Range 10 to 93% non - condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC /FWR' Operating Voltage Range' 8 to 17.5 V (12V nominal) or 16 to 33 V (24 V nominal) Input Terminal wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8 diameter x 2.5" high (173 mm diameter x 64 mm high) Wall -Mount Dimensions (including lens) 5.6 - L x4.7 - W x 2.5 mm L x 119 mm W x64 mm D) Horn Dimensions 5.6 - L x4.7 x 13 mm L x 119 mm W x 33 mm D) Wall - Mount Back Box Skirt Dimensions (BBS -2, BBSW - 2) 5.9 L x 5.0 "W x 22 "D (151 mm L x 128 mmW x 56 mm D) Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7.1" diameter x 2.2 - high (180 mm diameter x 57 mm high) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR -HS, TRW -HS) 5.7 x 4.8 - W x 035 - D (145 mm L x 122 mm W x 9 mm D) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC -HS, TRCW -HS) 6.9 diameter x 0.35 - high (175 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. I A05 -0395-007 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8 -17.5 Volts 16 -33 Volts 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 P 9 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non - temporal High 57 56 69 75 95 NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15 -115 cd) 8 -17.5 Volts 16 -33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - Temporal High 141 152 91 100 116 176 201 221 229 Non - Temporal Medium 133 145 75 85 102 163 187 207 216 Non - Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 . Temporal Low 129 151 76 86 101 160 184 194 201 Non - Temporal High 142 161 103 112 126 181 203 221 229 Non - Temporal Medium 134 155 85 95 110 166 189 208 216 . Non - Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, High Candela Range (135 -185 cd) 16-33 Volts 16 -33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non - Temporal Medium 242 259 293 299 Non - Temporal Medium 219 232 262 267 Non - Temporal Low 238 254 291 295 Non - Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8 -175 16 -33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non - Temporal High 82 82 88 88 93 92 100 100 5 Non - Temporal Medium 78 78 85 85 90 90 98 98 6 Non - Temporal Low 75 75 81 81 88 84 96 92 7' Coded High 82 82 88 88 93 92 101 101 8' Coded Medium 78 78 85 85 90 90 97 98 9 Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2 -wire horn strobe. A05 -0395-007 SpectrAlert Advance Dimensions 2.5" 6.8" II�II Dia. 2.5 11111 5.8' \ 1 II 11)) Wall -mount horn strobes Ceiling -mount horn strobes 7,1" 2.25 5.05" 2.23+1 - • - • .... Dia. gyp /000. 5.98" 1a O I Oo'eO i c Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Ceiling Strobes P2R " 2 -Wire Horn Strobe, Standard cd*, Red SCR Strobe, Standard cd, Red P2RH" 2 -Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red P2W" 2 -Wire Horn Strobe, Standard cd, White SCW" Strobe, Standard cd, White P2WH" 2 -Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White P4R" 4-Wire Horn Strobe, Standard cd, Red Horns P4RH 4 -Wire Horn Strobe, High cd, Red HR Horn, Red P4W 4 -Wire Horn Strobe, Standard cd, White HW Horn, White Wall Strobes Accessories SR " Strobe, Standard cd, Red BBS -2 Back Box Skirt, Wall, Red SRN"/ Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White SW" Strobe, Standard cd, White BBSC -2 Back Box Skirt, Ceiling, Red SWH" Strobe, High cd, White BBSCW -2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes TR -HS Trim Ring, Wall, Red PC2R" 2 -Wire Horn Strobe, Standard cd, Red TRW -HS Trim Ring, Wall White PC2RH 2 -Wire Horn Strobe, High cd, Red TRC -HS Trim Ring, Ceiling, Red PC2W"t 2 -Wire Horn Strobe, Standard cd, White TRCW -HS Trim Ring, Ceiling, White PC2WH" 2 -Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4 -Wire Horn Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White Notes: Add' -P"to model number for plain housing (no°FIRE° marking on cover), e.g., P2R -P. t Add " -SP "to model number for "FUEGO" marking on cover, e.g., P2R -SP. t "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95,110, and 115 candela settings. "High cd °refers to strobes that include 135, 150, 177, and 185 candela settings. —` X2009 system sensor. ��� 3825 Ohio Avenue • St. Charles, IL poduc[speclxnbns sugeclrochange vAhan noucr unit sys temser,sorcanfa `\y�l Phone: 800-SENSOR2 • Fax: 630-377-6495 current °! otl """r"`""`a" including the latest on of this data sheet. A05 -0395 - 007.4/09..2132