Loading...
Specifications - _- Form 5a Project Name: Fikt r J' LJdV Page: LIGHTING — GENERAL t 1. Interior Exceptions (Section 1313.1) OCT 3 0 L009 ❑ No Interior Lighting. The building plans and specifications do not call for new or altered interior Iighti0 Skip to item 5, Exterior building Lighting - General, below. CITY O( IGARD Exceptions ❑ Exceptions. 1. The building or part of the building qualifies for an exception from code lighting D +pa w DfVICO Discussion of qualifying requirements. Applicable code exception is number: 1Lrr exceptions in instructions section. 2. Lighting equipment that qualifies for an exception - in addition to general lighting and is separately controlled. Applicable code exception is number: Areas of the building and equipment that qualify for any exceptions: Plans /Specs Show compliance by including a drawing sheet, detail number, and /or specification section and subparagraph. 2. Local Shut -off controls (Section 1313.3.1.1) ❑ Complies. At least one local shut -off lighting control for every 2,000 square feet of lighted floor area and for all spaces enclosed by walls or ceiling height partitions. This control is detailed in the building plans on drawing number: ❑ Exception. The building or part of the building qualifies for an exception. Applicable code exception is Section 1313.3.1.1, Exception: SINGLE TENANT RETAIL Portions of the building that qualify: SALES & FITTING ROOMS 3. Automatic Shutoff Controls (Section 1313.3.1.2) ❑ Not Applicable. Office floor area is not over 2,000 square feet of contiguous office floor area or permitted space is not over 5,000 square feet. No offices less than 300 square feet, meeting or conference rooms, or school classrooms. l7 Complies. All interior lighting systems are equipped with a separate automatic control to shut off lighting during unoccupied periods. Offices less than 300 square feet, meeting and conference rooms, and school classrooms are equipped with occupancy sensors that comply with Section 1313.3.1.2.1. Compliance details in plans /specs: time clock ❑ Exception. The building or part of the building qualifies for an exception. Applicable code exception is Section 1313.3.1,2, Exception: Portions of the building that qualify: 4. Daylighting Controls (1313.3.1.3) 9 No classrooms or atriums with skylights or window to wall ratio greater than 50 %. ❑ Complies. All classrooms and atriums with window to wall ratio greater than 50% and /or skylights are equipped with automatic daylight sensing controls, as required by Section 1313.3.1.3.1 and Section 1313.3.1.3.2. The daylight sensors specified comply with Section 1313.3.1.3.3. Compliance details in plans /specs: Exterior Build 5. Exterior Lighting (Section 1313.5) ing Lighting ID Complies. The plans do not call for use of incandescent or mercury vapor lamps for use on building exterior. is lighting directed to ❑ Exception. The building plans indicate luminaires with incandescent or mercury vapor lamps, but are illuminate the exterior of the specified for use in or around swimming pools, water features, or other locations subject to requirements building and adjacent of Article 680 of the 2002 National Electrical Code. walkways and loading areas with or without canopies. Clock Switches 6. Exterior and Canopy Lighting Controls (Section 1313.3.2) shall be astronomic (seasonal ❑ Complies. The building plans and specifications include photoelectric and /or clock switches on all exterior correcting) type with separate lighting systems which are designed and programmed to extinguish lights when daylight is ores- . ,,,as,, programs for each day of the required by Section 1313.3.2. week and shall store energy . •' t� t'' i�� ('s ",� to maintain timekeeping during power outages. '��"�n��C3• gi p' , 7. Connected Lighting Power (Section 1313.4) zits ' ' YES Complies. The lighting power does not exceed the power allowance establishe S9$�5( s :,s' in either the Tenant Space Method (Form 5b) or the Space-by-Space Method •s. r F Tenant Space Method (Form 5b) r• Space -by -Space Method (Form 5c) \ • 1 02.-3\tiA 5-1 V2.4.3 - Compliance with 2007 OSSC Form 5c Project Name: 1 e_bki Page: INTERIOR LIGHTING POWER - Space -by -Space Method Lighting Power Budget 1. Total Interior Lighting Power Budget from Worksheet 5b -1 (Sum of Column (I)) 6,402 2. Total length of track lighting (ft) 150 Track Lighting Power 3. Line 2 multiplied by 50 Watts /ft 7,500 4. Total amperage of circuit breaker(s) serving track lighting (amps) 5. Voltage of circuit breaker serving track lighting (volts) 120 6. Maximum wattage of track lighting (multiply line 4 by line 5) 7. VA rating of the inline current limiter or the low voltage transformers 3,120 8. Track Lighting Power (the lesser value of line 3, 6 or 7) 3,120 Building's 9 . Total Interior Lighting Power from Worksheet 5b -1 (Sum of Column (m)) + 3,143 Interior 10. Total Adjusted Lighting Power (line 8 + line 9) = 6,263 Lighting Power 11. Does Interior Lighting Design Meet Budget? Line 10 must be no greater than line 1. YES Exterior Canopy Parking Garage 12. Do Exterior Canopies Meet Budget (Worksheets 5c)? N/A Lighting Power 13. Does Parking Garage Meet Budget (Worksheets 5c)? N/A 14. Does Each Space With Retail Display Lighting Meet Budget (Worksheets 5d)? YES Retail Display Lighting Power 15. Is The Total Retail Display Lighting Additional Power Less Than 17,500 W (sum of line 9 on Worksheets 5d)%. YES 16. Does Retail Display Lighting Meet Budget? YES 44y 5 -3 Compliance with OSSC, effective 01/01/05 • Work! Project Name: I FAL. ti// 1 Page:1 • LIGHTING FIXTURE SCHEDULE (see Table 5c in instructions for default luminaire power). c.) re) (c) (01 (a) (0 Lem Ltrntnatre le Luminaire ID LignInete Lamo 13.11Lasts Power Fran ... c Track Ligheng _ _ 50 YES User Defined .1 INCANDSCFNT RECESSED CAN 50W0.) g 50 WATT 50 NO G2 i Fluorescent Rapid Stan TB - 2 foot j 1-F17T8-ELECT NO.11111 J 1 run 1 El..1)c.T.1014a RS 22 YES o3 i Flutreuer4 Rapid Stan TI3 • 3 fool ,1 1-125T8-ELECT NO-270/ -I 1 52518 1 Electronic Naniel Output. RS 17 YES , c4 1 Fluorescent 113 - 4 ler4 -1 1-F32T8.130ES-ELECT NO EE-33W _ ,,) 1 F3278/30E3 1 EE (03)3)1) 00)1500 IS 33 YES L , luotascon1TB 4 loot .71 1•E3178/30EStELECT46 EE-33W .11 1 F3278/30ES 1 EE Normal Output IS , F - 33 YES c 1 i Track Ligteng Track Ugh.? _ _ _ 50 YES : - - - 1 , . .• .• -I ,..7.1 ----- - .2.1 .7.) .7.1 I ... . .. . --.— __. 22i : .71 • — •• • _,.. 2 i ......1 . ... — ---',- zi • • —i -- I . i ...1 -- 'r• . '...1 ------ .7.1 .....i .7.! A _ I TT :I • 4 . t. ..., . .1— •:., .4 71 __.. A A _ • .7.i ... f --, A 71 __. .4 - 4 --- ..---] —,- — 1 - - __. i .-.., .7.1 _,„.. .7.1 --4 _,. _,.... : .71 -----t. _11 _,. ,.....1 : ..-.2 • • ..I .!1 __. • .!..i 7i 2.1 5-4 . /2 a ! • Cempltana «, 2007 OS. • Worksheet 5b -1 Project Name: Pk. (.JA. Page: INTERIOR LIGHTING POWER Space-by-Space Method Only " Skip to column (1) if using the Tenant Space Method (a) (b) .. (c) (d) (e) LumnlD (g) (h) 0) G) (k) from Quantity of Room ID (do Space Type. Space Lighting Power Worksheet Luminaires (or Luminaire Lighting Room not leave any Area . - (Table 13-H) - Type Budget. _5a Column lineal ft. for track Power Exempt Power Total Ltg. blanks) (ft') (enter space type only once per room) LPD (b) x (d) li lighting) (Watts) - Fixtures (a ) 9 9) ( ) (g) x (h) Power Each room SALES 2681 Retail - Other Merchandise Sales Area 2 5,362 C -j 150 50 ❑ 7,500 15,740 must be SALES - - U - 30 33 ❑ 990 -- identified. FITTING 317 Dressing /Locker /Fitting Room 0.6 190 G2 8 22 ❑ 176 1,394 Describe luminaires for each FITTING _ _ G3 . 26 27 ❑ 702 -- individual room in FITTING - G4 .€ 2 33 ❑ 66 - plans. , FITTING - D -j 9 50 ❑ 450 -- RR 66 Restrooms 0.9 59 U -I 1 33 ❑ 33 33 CORRIDOR 65 Corridor/Transition 0.5 33 U 2 33 ❑ 66 66 For track lighting STCOK 947 Active Storage 0.8 758 U • 20 33 ❑ 660 660 enter lineal feet in SALES - - C1 145 50 ❑ 7,250 15,740 column column (g) . �(( ❑ - - - Column (k), enter - .=t - - - ❑ sum of column 0) -- _ _ -{ ❑ for each room only once at first entry - - for the room . See � _ ❑ _ example in -- ❑ instructions. - - ,. -- ❑ ... - '1 ❑ - -1 ❑ - - ❑ _ - - H - ❑ - - - - ❑ _ O J - ❑ ❑ . . 4,076 Worksheet 5b -1. Total Budget 6,402 Wksht 5b -1 Total Lighting Power (excluding exempt/track fixtures) 3,143 Other Pages Total Number of Additional Worksheet 5b I 0 List the additional worksheets nece- ssary to catalog all luminaires in ( (m) (n) building Lighting Power Budget: Space Proposed Buiding Lighting by-Space only (Total of Power (Total of column (k), Area Sqft. (not required Worksheet Number column (e)) excluding exempt/track) for Tenant Method) _.._1 6,402 3,143 4,076 5b -2 • 5b -3 . Sum of additional 5b worksheets >• 4 " ?* 6,402 3,143 4,076 Total Budget (of all worksheets) 5 -5 V2 4 .1 - Compliance with 2007 OSSC Worksheet 5d -1 Project Name: PAC, Page: Retail Display Lighting Power Complete one worksheet for each room (space) for retail display lighting that is specifically directed to highlight merchandise, and is controlled separately from the general lighting system within the room. General lighting should be included on Worksheet 5b. 1. Room # or Space ID .. - Sales 2. Room Area (ft°) - 2681 3. Retail Space Type Retail - Other Merchandise Sales A (a) .. Lum ID (b) (c) (d). from Quantity of Worksheet . Luminaires (or. Luminaire Lighting 5a Column lineal ft. for track Power. Power Describe (a) lighting) (Watts) (b)x (c) - luminaires for C1 145 . 50 - ,7,250 each individual room in plans. - - - - - For track lighting enter lineal feet in column (b). . 1. , Space Display Lighting Power (total d column excluding track fixtures) 0 2: Total length of track lighting (ft) . : - - 145 3. Line 2 multiplied by 50 Watts/ft - 7250 4. .: Total amperage of circuit breaker(s) serving track lighting (amps) 5.: Voltage of circuit breaker serving track lighting (volts)- ... - 120 6. Maximum wattage of track lighting (multiply line 4 by line 5) 7; . VA rating of the inline current limiter or the low voltage transformers 3240 8. Track Lighting Power (the lesser value of line 3, 6 or 7) . 3240. g.' Total Space Display Lighting Power (Watts) (line 1 if line 8) 3240 10. Total Space Display Lighting Power Budget (Watts) (room area x 1.75 to max 4691.75, 11. Does Space Retail Display Meet Space Budget (Line 9 less than line 10 YES and less than 17,500 W)? Total Number of Additional Worksheet 5d 0 UUUU rt:N flCT 302009 Form 4a Project Name: PACSUN - Washington Square Pag i iii OF TIGf RD SYSTEMS - GENERAL Rol ° DIVISION Applicability Plans /Specs Discussion of qualifying Show compliance by including a drawing sheet, detail number, exceptions on page 4 -25 specification section and subparagraph. 1. Applicablity (Section 1317) Is this form required? o Form Required. Complete form if a new HVAC system is being installed, or components of an existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) D Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1, Portions of the building that qualify: Area: Exception D -1 D -2 ❑ -3 Area: Exception D -1 ❑ -2 ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) D Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. 0 Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. • Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: ❑' -4a G -4b ❑ -4c D -4d D -4e D -4f ❑ -4g ❑ -4h ❑ -4i D-4. 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) D No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. D Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as reouired by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) • No Distribution Transformers. The plans /specs do not call for new distribution transformers. ❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. D Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: 0-1 D -2 D -3 0-4 0-5 0-6 0-7 0-8 D -9 ❑ - 0 - 1 D - D - 0 Attach relevant documentation for appropriate exception. The plans /specs show compliance in the f ,, following locations: 4 -1 - -- . Compliance with OSSC, effective 04/01/07 Form 4a Project Name: PACSUN - Washington Square Page: 2 SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) ❑ Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception ❑ -' 0-2 Portions of the building that qualify: I The plans /specs show compliance in the following locations: N/A - Existing Landlord Central System 6.2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3) ❑ Complies. Systems must have at least one of the following features: ❑ Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces served. ❑ Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: ❑ Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception 0 - 0 -2 The plans /specs show compliance in the following locations: NIA - Existing Landlord Central System 6.3 Control Capabilities (Sec. 1317.4.2.1) ❑ Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 0-1 0-2 Portions of the building that qualify: The plans /specs show compliance in the following locations: N/A - Existing Landlord Central System 6.4 Optimum Start Controls (Section 1317.4.3.2) ❑ Complies. Separate HVAC systems have controls capable of varying start -up time of system to just meet temperature set point at time of occupancy. ❑ Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: N/A - Existing Landlord Central System 6.5 Heat Pump Controls (Section 1317.4.4) ❑ No Heat Pump. The plans /specs do not call for a new heat pump ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. _,•: °.� The plans /specs show compliance in the following locations: ` \ •a N/A - Existing Landlord Central System 4 -2 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: PACSUN - Washington Square Page: 3 SYSTEMS - GENERAL 7. Economizer Cooling (Section 1317.3) O No Cooling. The building plans do not call for a new fan system with mechanical cooling. ❑ Complies. Each new fan system has an air economizer capable of modulating outside -air and return -air dampers to provide up to 100 percent of the design supply air as outside air. O Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317.3, Exception ❑ -1 O -2 ❑ -3 ❑ -4 ❑ -5 O -6 O -7 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu /hr) (b) Total installed building cooling capacity (Btu /hr) ❑ Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 Btu /hr or a/b < 0.10 (10% of total building cooling capacity). Unit Identifier of exempt units: The plans /specs show compliance in the following locations: N/A - Existing Landlord Central System 8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2) ❑ No Economizers Required. Project does not contain a new fan system requiring economizers. ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. ❑ Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling Toad. ❑ Exception. The applicable exception is Section 1317.3.2, Exception ❑ -1 ❑ -2 The plans /specs show compliance in the following locations: N/A - Existing Landlord Central System 9. Hot Gas Bypass (Section 1317.5) El No Hot Gas Bypass ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity Allowable Hot Gas Bypass : i ; , � , ��.;ti;,; Rated Cooling Capacity Max Hot Gas Bypass \O/ <240,000 Btu /hr 50% J >240,000 Btu /hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h • 4 -3 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: PACSUN - Washington Square Page: 4 SYSTEMS - GENERAL 10. Shutoff Dampers (1317.4.3.3) ❑ Not Required. Shutoff dampers are not required on this project. ❑ Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers. ❑ Exception. The building qualifies for an exception to the motorized damper requirement. The applicable code exception is Section 1317.4.3.3 Exception ❑ -1 ❑ -2 ❑ -3 ❑ -4 ❑ -5 ❑ -6 The plans /specs show compliance in the following locations: N/A - Existing Landlord Central System 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) ❑ Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. ❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. The plans /specs show compliance in the following locations: N/A - Existing Landlord Central System 10.2. Motorized Damper Leakage (1317.4.3.3.2) ❑ Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. ❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: N/A - Existing Landlord Central System 11. Piping Insulation (Section 1314) el No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. ❑ Complies. All new piping serving a heating or cooling system or part of a circulating service water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for exception: Section 1314.1, Exception 0 -1 ❑ - 2 12. Occupancy Ventilation ❑ Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated in plans /specifications as specified in Chapter 4 of the Oregon Mechanical Specialty Code. ❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet 4m. The plans /specs show compliance in N/A - Existing Landlord Central System the following locations: The plans /specs show compliance `=' :, ;, A` -�� N/A - Existing Landlord Central System , on the following pages: 43 4 -4 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: PACSUN - Washington Square Page: 5 SYSTEMS - GENERAL 13. High Occupancy Ventilation (Section 1317.2.2) ❑ Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant Toad of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: Plans /specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified: N/A - Existing Landlord Central System ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. ❑ No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Exhaust Air Heat Recovery (Section 1318.3) • Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min. outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air supply. ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception ❑ -A 0-2 0-3 0-4 0-5 0 0-7 The plans /specs show compliance in the following locations: 15. Large Volume Fan Systems (Section 1318.4.2.4) ❑ Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following N/A - Existing Landlord Central System locations: 16. Variable Speed Drives (Section 1317.10.3.1) ❑ Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. O Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: N/A - Existing Landlord Central System Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following locations: 17. Service Water Heating (Sec. 1315) ❑ No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. O Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: Portions of the building that qualify: The plans /specs show compliance in the following locations: P100 • _ .. 4 -5 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: PACSUN - Washington Square Page: 6 SYSTEMS - GENERAL 18. Swimming Pools, Spas and Hot Tubs (Section 1315.5) El No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. O Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) O No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: ❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: 20. Parking Garage Ventilation (Section 1317.2.3) El No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) ❑ Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) ms p , uncooled or evaporatively cooled. ''. =k; The plans /specs show compliance in the following locations: ` \a =% / N/A 22. Outside Heating Systems (Section 1317.12) No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. ❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4 -6 Compliance with OSSC, effective 04/01/07 Form 4b Project Name: PACSUN - Washington Square Page: 7 COMPLEX HVAC SYSTEMS Applic 1. Simple or Complex Systems (Section 1317.9, 1317.10 and 1318) ability Note: This form is required for complex systems only. If your plans qualify as a simple system Discussion of as defined by the code, this form is not required. qualifying excep- tions 2. Air Transport Energy (Section 1318.4.2) instructions section. ❑ Not Regulated. Each HVAC system does not have total fan nameplate horsepower of 7.5 HP Fan Motor or greater (include sum of all supply, return, & exhaust fans operating at design conditions). Energy ❑ Brake Horsepower Complies. The energy demand of all HVAC fan systems meets code See Section 1318.4.2 for requirements. Complete and attach Worksheet 41. q P maximum horse- ❑ Nameplate Horsepower Complies. Selected fan motors have nameplate ratings no larger power allowed. than is allowed by Section 1218.4.2.3. (Complete Worksheet 4L.) ❑ Exception. Section 1318.4.2, Exception 0-1 0 -2 0 -3 0-4 Portions of the building that qualify: The plans /specs show compliance in the following locations: N/A - Existing Landlord Central System Cooling 3. Cooling Tower Fans (Section 1317.5.4.1) Tower ❑ No Cooling Tower There is no cooling tower in this project. Fans ❑ Complies. Cooling tower fans have control devices that vary flow by controlling leaving fluid temperature or condenser temperature /pressure of the heat rejection device. The plans /specs show compliance in N/A - Existing Landlord Central System the following locations: 4. Simultaneous Heating and Cooling (Section 1318.2.1) ❑ No Cooling. The building HVAC system has no cooling. l7 Complies. Controls prevent reheating, recooling or mixing of mechanically heated and mechanically cooled air. ❑ Exception. Code exception is Section 1318.2.1, Exception 0-1 0 -2 0 -3 0 -4 ❑ -s If exception 1 is used, complete and attach Worksheet 4k Portions of the building that qualify: The plans /specs show compliance in M100, M200, M300 the following locations: 5. Electric Motor Efficiency (Section 1317.10.3 & Table 13 -T) ❑ Not Regulated. There are no NEMA Design A &B squirrel cage,T -frame induction, permanently wired polyphase motors of one horsepower or more which serve built up HVAC systems. ❑ Complies. The efficiency of all regulated motors meets code requirements. Exceptions ❑ Exception. Section 1317.10.3, Exception 0-1 0-2 Discussion of qualifying Portions of the building that qualify: exceptions in instructions section. The plans /specs show compliance in the following locations: N/A - Existing Landlord Central System 6. VAV System Static Pressure Reset Controls (Section 1318.2.3) ❑ Not Regulated. The building plans or specifications do not call for a VAV system controlled by a static pressure sensor or direct digital control of individual zone boxes. ❑ Complies. The system static pressure set point automatically resets to the lowest point possible while still providing the required greatest demand. air flow to the zones with the P P 9 q g 4'04;741 ; 1 ❑ Exception. Section 1318.2.3, Exception - = : 4J The plans /specs show compliance in N/A - Existing Landlord Central System the following locations: 4 -7 Compliance with OSSC, effective 04/01/07 Form 4b Project Name: PACSUN - Washington Square Page: 8 COMPLEX HVAC SYSTEMS 7. VAV Terminal Units (Section 1317.4.2.1 ❑ Not Regulated. Project does not contain VAV terminal units. • Complies. VAV terminal units are programmed to operate at the minimum airflow setting without addition of reheat when the zone temperature is within the set deadband. Complete Worksheet 4k. ❑ Exception. Section 1317.4.2.1, Exception ❑ -t 0- The plans /specs show compliance in the following locations: 8. Supply -Air Temperature Reset Controls (Section 1318.2.5 ❑ Not Regulated. The building plans or specifications do not call for multiple zone HVAC systems. ❑ Complies. Multiple zone HVAC systems include controls that automatically reset the supply -air temperatures in response to building loads or outside air temperature. ❑ Exception. The building qualifies for an exception to the supply -air reset controls requirement. Applicable code exception is Section 1318.2.5, Exception 0- 0-2 0-3 Portions of the building that qualify: The plans /specs show compliance in the N/A - Existing Landlord Central System following locations: 9. Chilled and Hot Water Temperature Reset Controls (Section 1318.2.4 • Not Regulated. The building plans or specifications do not call for chilled or hot water systems with a design capacity exceeding 300,000 Btu /hr. ❑ Complies. Chilled and hot water systems include controls that automatically reset supply water temperatures by representative building loads or by outside air temperature. ❑ Exception. Section 1318.2.4, Exception ❑- ❑ - Portions of the building that qualify: The plans /specs show compliance in the N/A - Existing Landlord Central System following locations: 10. Separate Air Distribution Systems (Section 1318.2.7 • Not Regulated. The building plans or specifications do not call for zones with special process temperature or humidity requirements. ❑ Complies. Separate air distribution systems serve zones with special process temperature or humidity requirements from those zones serving only comfort conditions, or supplementary control provisions are included so primary systems are specifically controlled for comfort purposes only. ❑ Exception. Section 1318.2.7, Exception ❑-t 0 -2 Identify zones with special process requirements: The plans /specs show compliance in the following locations: 11. Zone Isolation Controls (Section 1318.2.6 DI Not Regulated. Building plans or specifications do not call for HVAC systems serving multiple occupancies or floors with >240,000 Btu /hr cooling capacity, or >300,000 Btu /hr heating capacity. ❑ Complies. HVAC systems serving multiple occupancies or floors with >240,000 Btu /hr cooling capacity, or >300,000 Btu /hr heating capacity are equipped with isolation devices capable of automatically shutting off supply air to and from each isolated area. Each isolated area is controlled independently and satisfies temperature setback (Section 1317.4.2) and optimum start control requirements. Central fan system air volume is reduced through fan speed reduction. The plans /specs show compliance in the a' =,4 following locations: 4 -8 Compliance with OSSC, effective 04/01107 • Form 4b Project Name: PACSUN - Washington Square Page: 9 COMPLEX HVAC SYSTEMS 12. Humidity Controls (Section 1318.2.2) 0 No Moisture Added to Building. The building plans do not call for means to add moisture to maintain specific humidity levels. ❑ Complies. All new humidity control systems equipped with a humidistat when required. All humidifier preheating devices have an automatic value to shut off preheat when humidification is The plaris /specs show compliance in the following locations: 13. Hydronic System Controls (Section 1318.2.8) O No Hydronic System. The building plans or specifications do not call for a new hydronic system. ❑ Complies. The hydronic system complies as follows: 13.1 Variable Flow Controls (Section 1318.2.8.4) ❑ System does not have a 10 hp or greater motor ❑ Complies. System has controls capable of varying pump flow The plans /specs show compliance in ' the following locations: 13.2 Three -Pipe System (Section 1318.2.8.1) ❑ System does not have a common return system (a three -pipe system) for both hot water and chilled water. 13.3 Two -Pipe Changeover System (Section 1318.2.8.2) ❑ System is not a Two -Pipe Changeover System ❑ Complies. System is: a. Designed to allow a deadband between changeover from one mode to the other of at least 15 °F outside air temperature. b. Designed to operate and provided with controls that will allow operation in one mode for at least four hours before changing over to the other mode. c. Provided.with reset controls that allow heating and cooling supply temperatures at the changeover point to be no more than 30 °F apart. The plans /specs show compliance in the following locations: 13.4 Hydronic (Water Loop) Heat Pump System (Section 1318.2.8.3) ❑ System is not a Hydronic (Water Loop) Heat Pump System ❑ Complies. Hydronic heat pumps connected to a common heat pump water loop with central devices for heat rejection (e.g., cooling tower) and heat addition (e.g., boiler) have the following: a. Controls installed capable of providing a heat pump water supply temperature deadband of at least 20 °F between initiation of heat rejection and heat addition by the central devices (e.g., tower and boiler). b. Closed- circuit tower (fluid cooler) has either an automatic valve installed to bypass all but a minimal flow of water around the tower (for freeze protection), or low- leakage positive closure dampers. c. Open - circuit tower installed directly in the heat pump loop has an automatic valve installed to bypass all heat pump water flow around the tower. Open - circuit towers used in conjunction with a separate heat exchanger to isolate the tower from the heat pump loop are controlled by shutting down the circulation pump on the cooling tower loop. �.,5 -, d. A two - position valve at each hydronic heat pump for hydronic systems having a total pump system power exceeding 10 hp. 0 ° l The plans /specs show compliance in the following locations: • 4 -9 Compliance with OSSC, effective 04/01/07 Worksheet 4k Project Name: PACSUN - Washington Square Page: 10 Simultaneous Heating and Cooling Additional pages may be necessary if building has more terminal units than there are lines in this form. If needed use Add New Worksheet button Complete this form for all terminal units with reheat to verify compliance with Section 1318.2.1 exception 1. Terminal Unit (Variable Air Volume (VAV) Box) CFM Design Conditions Required Information Comply Max. Ht CFM Ht. CFM Ht. CFM Maximum Cooling Occupancy < or = to < or = to < or = to Airflow is Terminal Unit ID or Sq. ft Area Airflow- Max. Heating Ventilation- 30% of 0.4 CFM Occupancy < or = to Description /Location Served CFM Airflow -CFM CFM Max per sq. ft Ventilation 300 CFM VAV -1 1474 1650 470 442 YES YES NO NO VAV -2 1474 1600 470 442 YES YES NO NO VAV -3 1114 1600 470 167 YES NO NO NO 4-21 Compliance with OSSC. effective 04!01107 Worksheet 4m Project Name: PACSUN - Washington Square Page: 11 NATURAL VENTUJATI• N 1. Fill in worksheet for all spaces that will be provided with natural ventilation. (a) (b) (C) (d) (e) (f) (9) (h) ( (i) (k) Space Estimated Max used to determine Required (Room # Occupant Load ventilation Required CFM/Sqft Net Free or name from OMSC Table Check if requirements CFM /person (from Required Area of Opening Calculated Natural from Room 403.3 Smoking (persons /1000sgft. (from Table Table Ventilation Outside Air Area / Floor Ventilation to Space plans) Area (sqft) (persons /1000sgft.) Area ) 403.3) 403.3) CFM Openings Area (design conditions)2 Sales 2948 ❑ 0.3 884 Non -Sales 1114 ❑ 0.15 167 O 1 Use this column when ventilation requirement is based on CFM /sq ft per OMSC Table 4.3.3. 2 Complete this column if net free opening is less than 5% of floor area or 20% of floor area for smoking areas, otherwise enter N /A. Attach calculations. Number of Additional Worksheets 4m ( 0 J 2. Describe calculation method used to determine ventilation delivered. Attach additional sheets as necessary N/A - Ventilation air is delivered through the Landlord's Central HVAC System 3. Attach manual calculations, spreadsheets, computer model input and outputs, and other technical documentation that verifies o6Z . �o required ventilation will be provided to each space. J � :''sc;,\ 4. I certify that to the best of my knowledge, the natural ventilation calculations provided are correct. , ,._? :..- .... .._ This line to be signed and stamped by Architect or Engineer Registered in the State of Oregon. 4-23 Compliance with OSSC. effective 04/01/07 December 08, 2009 REC EIVED 4 . Dan Nelson DEC 1 2009 City of Tigard Building Department — Senior Plans Examineer el T Y OF TIGARD Re: Tenant Improvement, Pac Sun — Washington Square BUILDING DI M•ENGINEERING Emphasis on Excellence Dear Mr. Perez: M•Engineering, Inc. Following are the responses to structural comments on the afore - mentioned project plans provided by the Building Department Plans Examiner in letter dated December 2, 2009. Please review our responses in conjunction with new structural drawings and structural calculations attached herewith. Mechanical. Electrical, Industrial and Comment 1: Structural Engineers Provided new structural details and calculations documenting our engineering design for suspended ceiling and its framing. Comment 2: Provided new structural details and calculations documenting our engineering design for partition wall bracing to the underside of existing structure approximately 30' 10 West Hubbard Street, Suite 3N above aff. Comment 3: Provided structural calculations and design details for cash wrap suspended ceiling framing. Chicago, IL 60610 Sincerely, 4 0IN 44 82861 P - 312.494 -1170 Alpesh Chavda, PE a OREGON •'lf���� 9 Y 12 , 20� SHC- EXPIRES: L2fr]1'01 312. 494 -1037 FAX E - Mail: engineering c©i m- corporations.com An M•Corporation