Permit CITY OF TIGARD ELECTRICAL PERMIT t: COMMUNITY DEVELOPMENT Permit#: ELC2013 00580 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 09/30/2013 Parcel: 25101 CA00400 Jurisdiction: TIGARD Site address: 7940 SW HUNZIKER RD Project: Charter Mechanical Subdivision: 2007-064 PARTITION PLAT Lot: 1 Project Description: Replace damaged 600amp panel. Contractor: CAPITOL ELECTRIC CO INC Owner: MERITAGE FIVE LLC 11401 NE MARX STREET 7940 SW HUNZIKER RD PORTLAND,OR 97220 TIGARD,OR 97223 PHONE: 503-255-9488 PHONE: FAX: 503-257-7121 FEES Quantity Description Date Amount 1 ea Services or Feeders-401 to 09/30/2013 $200.34 Specifics: 600 amps 1 ea 12%State Surcharge- 09/30/2013 $24.04 Type of Use: COM Electrical Class of Work: ALT Type of Const: Occupancy Grp: Total $224.38 Required Items and Reports(Conditions) This pe.• • is issued subs to the regulations contained in the Tigard Municipal Code. State of OR. Specialty Codes and all other applicable law. All work will be ••ne in accordance with ap•roved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 d. s. ATTENTION: Oregon law\requi.= you to follow the rules adopted by the Oregon Utility •• enter. Those rules are set forth in OAR 52-001-0010 through OAR 952-001-1s•0. o =y obtain a copy of the rules or direct questions to OUN -by.•' -50 32.1987 or 1.800.332.23.4. • Issued By: ' _ /_ l J —/ Permittee Si ature: , i� _V. (‘' OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale,lease or rent. OWNER'S SIGNATURE Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR.ELEC' Date: • LICENSE NO. Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the Job site at the time of each Inspection. Electrical Permit Application FOR OFFICE USE ONLY R eceived gg �I �,/City of Tigard Date/By: J �3 'Permit no.: I �j�S• 13125 SW HaII Blvd.,Tigard,OR H:ECEED Plan Review C Phone: 503.639.4171 Fax: 503.598.le 60, Date/By: Other Permit: T l G A R D Inspection Line: 503.639.4175 J e➢ ® 2 3• Date Ready/By: Juris: Li See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information CITYOFTIGARD TYPE OF WORK BUILDItK DI'/ISIfw PLAN REVIEW L] New construction U Addition/alteration/replacement Please check all that apply(submit 2 sets of plans wfitems checked below): ❑ Demolition ❑ Other: ❑Service or feeder 400 amps or more ❑Building over three stories CATEGORY OF CONSTRUCTION where the available fault current ❑Marinas and boatyards U I-and 2-family dwelling U Commercial/industrial U Accessory building exceeds 10,000 amps at 150 volts or ❑Floating buildings ❑ Multi-family ❑ Master Builder ❑Other less to ground,or exceeds 14,000 ❑Commercial-use agricultural JOB SITE INFORMATION AND LOCATION amps for all other installations. buildings Job no.: 131518 Job site address: 7940 Sw Hunzlker Road ❑Fire Pump ❑ Installation of 75 KVA or ❑Emergency system larger separately derived system. City/State/ZIP: Tigard,OR.97223 CI Addition of new motor load of ❑"A","E","1-2","1-3", 100HP or more. ❑ occupancy Suite/bldg./apt.no.: Project name: Charter Mechanical ❑Six or more residential units ❑ Recreational vehicle parks. ❑ Health-care facilities ❑ Supply voltage for more than Cross Street/Directions to job site: ❑ Hazardous locations 600 volts nominal. ❑ Service or feeder 600 amps or more Subdivision: Lot no.: FEE SCHEDULE Descriptio^ I Qty. I Fee. I T.,tat ' Tax map/parcel no.: New residential-single or multi-family dwelling unit. DESCRIPTION OF WORK Includes attached garage. Replace damaged 600amp Service panel 1000 sq.ft.or less $ 168.54 4 Ea.Add'I 500 sq.ft or portion $ 33.92 I U PROPERTY OWNER I LI TENANT Limited energy residential Name: (with above sq.ft.) S 75.00 . 2 Limited energy,multi-family Address: residential(with above sq.ft.) $ 75.00 2 Service or feeders installation,alteration,and/or relocation City/State/ZIP: 200 amps or less $ 100.70 2 201 amps to 400 amps $ 133.56- 2 Phone: Fax: 401 amps to 600 amps 1 $ 200.34 200.34 2 601 amps to 1000 amps $ 301.04- 2 Owner installation: This installation is being made on property that I own which is not Over 1000 amps or volts $ 552.26 2 intended for sale,lease,rent or exchange,according to ORS 447,449,670,and 701 Temporary services or feeders installation,alteration,and/or Owner signature: Date: relocation 200 amps or less S 59.36_ 1 U APPLICANT I U CONTACT PERSON 201 amps to 400 amps $ 125.08 2 Business Name: 401 amps to 599 amps 5 168.54 2 Branch circuits-new,alteration,or extension,per panel Contact name: A. Fee for branch circuits with 1 service or feeder fee,each Address: branch circuit S 7.42 2 B. Fee for branch circuits without service or feeder fee, City/State/ZIP: _first branch circuit $ 56.18 2 Phone: Fax: Each additional branch circuit: $ 7.42 2 Miscellaneous(service or feeder not included) E-mail: Each manufactured or modular CONTRACTOR dwelling,service and or feeder _$ 67.84 2 Business Name: CAPITOL ELECTRIC CO.,INC. Reconnect only $ 67.84 2 Pump or irrigation circle $ 67.84 2 Contact name: Sign or outline lighting _ $ 67.84 2 Signal circuit(s)or limited-energy See Address: 11401 NE MARX ST. panel,alterations,or extension. Page 2 2 Each additional inspection over allowable in any of the above City/State/ZIP: PORTLAND,OR 97220-1041 Additional inspection(I hr min) 66.25/hr Investigation(I hr min) 66.25/hr Phone: 503-255-9488 Fax: 503-257-7121 Industrial plant(I hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: 48748 'Electrical Lic.: 26-496C ISu rv.Lic 2865- specifically listed(1/2 hr min) Suprv.Electrician signature,required: 2 ELECTRICAL PERMIT FEES Subtotal: $ 200.34 Print Name: Richard Martin Date: 09/27/1 Plan review(25%of permit fee): Authorized signature: State surcharge(12%of permit fee): $ 24.04 TOTAL PERMIT FEE: $ 224.38 Print Name: Richard Martin This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. •Number of inspections per permit allowed. I:\Building\Permits\ELC-PcnmitApp.doc 10/01/09 440-461 mil/OS/COM/WEB 1/05/COM/WEII UPv Capitol Electric Q., 503-255-9488 FAX 503-257-7121 MEMO TO: PGE FROM: Richard Martin DATE 9/27/2013 RE: 7940 SW Hunziker Road Charter Mechanical Emergrency reconnect at Charter Mechanical due to electrical service being damaged by being shorted out by accident. Thanks, Richard Martin 971-506-3711 ' . Request to Energize an Electrical Installation , ©�; J Jurisdiction address: L REQUESTING SUPERVISING ELECTRICIAN INFORMATION Name of supervising electrician: Richard Martin Date of request: 9 / 27 / 13 Supervising electrician's license number: 2865-S )ate installation was completed: 9 / 27 / 13 Electrical permit no.: If a temporary permit is posted at the job site,please include a copy of it with this form. EMPLOYING ELECTRICAL CONTRACTOR INFORMATION Name of electrical contractor: Capitol Electric Co., Inc. License no.: 26-496C Business address: 11401 NE Marx Street City: Portland State: OR ZIP 97220-1041 Phone: 503-255-9488 Fax: 503-257-7121 Email: richardm@cepdx.com CUSTOMER INFORMATION Customer's name: Charter Mechanical Customer's address: 7940 SW Hunziker Road City:Tigard State: Or ZIP 97223 Address of installation if different than customer's address: City: Portland State: Or ZIP INSPECTING AUTHORITY INFORMATION Authority having jurisdiction to inspect: City Of Tigard Phone: 503 - - Address: 13125 SW Hall Blvd. City:Tigard State: OR ZIP 97223 RECEIVING ELECTRIC UTILITY INFORMATION Name of electric utility receiving request: PGE Phone: - - Address: City: State: ZIP REASON FOR REQUEST A. Restoring electrical service that was interrupted or disconnected because of either a: ❑ Service change or fie Uncontrollable event, such as fire, flood, or severe weather; or B. Electrical service at a remote location needs to be: ❑ Initialized ❑Restored COMPLETION INSTRUCTIONS AND SIGNATURE Supervising electrician Electrical contractor Please note-After sending this form to the electric Please note-By close of business on the first business utility named above,you must send a copy of this form to: day, following energizing of a completed installation in (1) the electrical contractor, (2)the customer, (3)the response to the above request, you must: (1) notify the inspecting authority. authority having jurisdiction that the installation has been energized, and (2) request that the authority inspect the 09/27/13 completed installation. Supervising electrician's signature Date r DEPARTMENT F CONSUMER ES �S�RVI EES 440-0948-COM(9/08/COM © 0 py Portland General Electric Company E 09/27/13 /G CONTACT: RICHARD W CAPITOL ELECTRIC PHONE: 971-506-3711 CUSTOMER NAME: CHARTER MECHANCIAL ADDRESS: 7930 SW HUNZIKER RD.,TIGARD SDPM/ENGR: MILO STARR WR: 0 PHONE: 503-570-4414 3-PHASE SECONDARY LINE-LINE FAULT CURRENT (RMS) TRANSFORMER DATA PAD MOUNT? NO XFMR Impedance(%): 1.7 % 3-PH SUBMERSII YES TRANSFORMER SIZE: 1000 KVA XFMR? NO Secondary VOLTAGE(L to L): 480 v WYE OH BANK? YES VAULT--> VAULT ( or Pole --> Pole) SECONDARY Secondary Wire LENGTH: 0 Feet WIRE SIZE Number of SECONDARY RUNS: 1 Run(s)of: Secondary WIRE Resistance R: 0.0180 Ohms/1000' Secondary WIRE Reactance X: 0.0258 Ohms/1000' VAULT ( or Pole) --> PANEL SECONDARY (or Svc Drop) Service Wire LENGTH: 50 Feet WIRE SIZE Number of Service RUNS: 3 Run(s)of: 4/0 OX M Service WIRE Resistance R: 0.0820 Ohms/1000' Service WIRE Reactance X: 0.0310 Ohms/1000' MAXIMUM FAULT CURRENT*: 51,531 Amps *Maximum fault current based upon transformers/conductors sized for 100% of electrical panel rating. Based on a panel size of: 600 AMP Amps To Print This Page: "Ctrl M"and choose"Print 3-Phase Data"