Plans 0 n MEWED 0 • a, m a m m `` 3 000 FIRE ALARM EQUIPMENT s SCOPE OF WORK JUN 2 4 2013 Qo0NN SYMBOL DESCRIPTION PART # ROUGH-IN/NOTE MOUNTING HEIGHT -A-043,D FIRE ALARM CONTROL PANEL FCI SELF-CONTAINED SURFACE MOUNT EXISTING MODIFY NOTIFICATION IN A EXISTING ADDRESSABLE CBEHTRAL� II STATION CITYOFTIGARD ' w � I� WITH SURFACE BACK BOX 7100-2D 20.111 X 14.09'W X 4.55'D in to-1"" OFF-SITE REPORTING. HORN/STROBES. AND STROBES. BUILDINGDNISION ma FIELD CHARGING POWER SUPPLY SILENT KNIGHT SELF-CONTAINED SURFACE MOUNT 54' TO TOP OF HIGHEST z WITH SURFACE BACK BOX 5495 16.0'H X 12.251V X 3.0'D USER FUNCTION AFF Q • ; HORN STROBE - RED WHEELOCK 80' MIN TO LENS BOTTOM AFT (NAC AND CANDELA NOTED AT DEVICE) HSW SINGLE-GANG VERTICAL 96' MAX TO TOP OF LENS AFF i 6'MIN TOP OF LENS TO CFJUNG 80'MIN TO LENS BOTTOM AFF �l (NAC STROBE AND CANDELA NOTED AT DEVICE) S�jylr SINGLE-GANG VERTICAL 96'MAX TO TOP OF LENS AFF GENERAL NOTES I 6'MIN TOP OF LENS TO CCUNC I` 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA Eq O 72 AND NFPA 70. ARTICLE 760, POWER UNITED SYSTEMS. s1 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR SHALL BE RISER RATED. 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND UGHTNING PROTECTION DEVICES. 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY PROTECTED. DETECTOR SCHEDULE MODULE SCHEDULE 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING. IDENTIFIED AS 'FIRE ALARM CIRCUIT'. NO CHANGES NO CHANGES 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.4 PRIVATE MODE (NFPA 72). 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION N OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA 72). N 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH / n FIRE ALARM OPERATIONAL MATRIX SECTION 14.6.2.4 (NFPA 72). 11. A LOCKABLE DOCUMENT STORAGE CAN SHALL BE PROVIDED. V NO CHANGES Z ct z Z SITE < a H- FIRE ALARM RISER DIAGRAM _1 ~ NO CHANGES IZ C ) J v►R0,a LL I- •• NOTIFICATION CIRCUIT SCHEDULE/ VOLTAGE DROP MEASUREMENTS S•�''� LLJ N Q CKT/ DEVICE LOCATION /AREA CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT ORIGIN AMPS DIST SIZE,DROP AT EOL DROP DROP X w o �{ N-5 HORN/STROBES. STROBES DAVIDSON BENEFITS PLANNING TI FCPS 0.630 430 14 1.66 18.74 YES 8.15 CO �l N-6 SPARE SPARE FCPS 0.000 0 14 0.00 20.40 YES 0.00 O cK N-7 SPARE SPARE FCPS 0.000 0 14 0.00 20.40 YES 0.00 J N m LLJ N-8 SPARE SPARE FACP 0.000 0 14 0.00 20.40 YES 0.00 c/ ***END OF UNE METHOD - VOLTAGE DROP CALCULATIONS*** \ 0 j LL o D BATTERY CALCULATIONS FCI 7100-2D t > in NO CHANGES < N 0 M co r` BATTERY CALCULATIONS SILENT KNIGHT 5495 CITIf ®F TIGARD STANDBY(HRS): 24 MAIN FLOOR MECH (004) Approved (A,. r `X ALARM TIME (ION): 5 J PART# DESCRIPTION OTT STANDBY EA.STANDBY TOTAL ALARM EA. ALARM TOTAL Conditionally Approved,........... '• SK 549 5 FIELD CHARGING POWER SUPPLY 1 0.0750 0.0750 0.2050 0.2050 See Letter to:Fol low DATE • 0 06/17/13 NAC-5 DAVIDSON BENEFITS PLANNING TI 1 0.0000 0.0000 0.6300 0.6300 Atta.hed........ ....... NAC-6 SPARE 1 0.0000 0.0000 0.0000 0.0000 L� s� r rr'i NAC-7 SPARE 1 0.0000 0.0000 0.0000 0.0000 Permit Number: �1�� - �s r. NAC-8 SPARE 1 0.0000 0.0000 0.0000 0.0000 Address: ✓Z •P� f�ug...4 OWN BY: STANDBY AMPS = 0.0750 ALARM AMPS = 0.8350 Br IN sm Date: OM SMB STANDBY A-HR = 1.8000 ALARM A-HR = 0.0696 MOM BY • AMPERE HOURS REQUIRED = 1.8696 MGH 20%DERATE = 2.2435 Approved plans FITE NAM i BATTERIES TO BE INSTALLED = 7 AMPERE HOURS_ shall be on job sit�J• FA.dwg shall YY Uri job DRA IG R OFFICE COPY FA- 1 ,OF DM6S IN SET: SHEET 1 OF 2 _....._ i i► _ Aiir ► I�/ i� i� 0, x , II /. .l� I 1 1 3 8 0 0 s .00 1 0 22 of 1 W n n� II ! t I ( 0 oaDMM 0O Y W 107Q�ff� Y)InJvv al JOHN'S OFFlC �REAI(ROOM I V-- —,I T�'► I '�.® , 115 J �� ► `I 1 II �I ,—.----------------! 116 N-5 � — �'�T��I. I � 1�/ - Al iMP .;III: ). ....-T I a V4riIr-- i�'■N /Arsvi•/ is Iij 11- II I� ,.CI�J., 1 Ar r Akio Sz 4=--l- A - -if .. L__ ..4_ .42, AA l(r) i2.4 Ng wII _ ,� w .z. ., � // I I frAmr >—/ fL) L,,f.) , , Al (i) I * i ! I. . , I � w I • L � I ERE - ~l •• ,0 MOS . :11'r'©• ug 1 � � °�.f Q N-5 _15 1111 El MI ® _ / Q w a 1 1111 III - z = 108 _ NII IN 1 EgrAITING 0 Q 1 N ; Q 15-5 ©:=: J: NG / N N-5 r1 : '••• 15 S 30 I CV m 0 0 I i ( 06l ( 05� 04) 03) . 1, ,• , I rIII DO / DO6/17/13• FLOOR PLAN LL_ :.__.______,___.. SCALE: 3/32" = 1'-0" \`\\ I 1 DRAIN er.SMB aaaao BY: :e �' 0 8' 16' 24' I I I L I MGH I1XIOZ .n.E" I ,.0 SCALE: 3/32"=1'-0" FA.dwg p F - 2 0 © © U el SHEET 2 OF 2 FP5 zo 13-ar'o g3 REcEDIED 4 20� Series Gamewell 3�N 2 1100 FIRE o%MTROL CTCY 0�UNI N INSTRUMl3JT5 e*' by Honeywell BUILDING Description Compact Analog Addressable The Gamewell-FCI 7100 Series fire alarm control panel is a Fire Alarm Control Panel multi processor-based, analog addressable system. The control panel is a compact, yet expandable, platform. Intended for commercial, industrial and institutional instal- lations,the 7100 Series is ideal for life safety and property protection fire alarm applications. - The basic 7100 Series control panel provides one (1) or —""" two(2),analog addressable Signaling Line Circuits(SLCs). Each SLC supports up to ninety-nine(99)analog address- able sensors, as well as up to ninety-eight (98) address- able monitor modules and/or control points. With 197 addresses available on the 7100-1 and 394 addresses �' available on the 7100-2. The 7100 uses an advanced pro- tocol that ensures an almost instant response to events while at the same time suppressing nuisance alarms. 7100 Series Features The system may be programmed with either the • IBC Seismic Certified ®_ • Listed per ANSI/UL 864 9th Edition Windows based Field Configuration Program(FCP-7100) or configured through a comprehensive set of intuitive, • 120 or 240 VAC(optional)input line voltage secure password protected front-panel programming • Front panel programming with day/night sensitivity options.This important feature allows the system to quickly adjustments adapt to any future requirements due to changes in occu- • 80-character alpha-numeric display pancies,building remodels,or other contingencies. • One or two Style 4(Class"B")signaling line circuits. Style 6(Class"A")with optional CAOM Module The sophisticated circuitry and powerful analog software • Two Style Y(Class"B")regulated notification appliance enables the 7100 Series fire alarm control panel to read the circuits rated for 1.5 amp each. Style Z(Class"A")with specific sensitivity level of each sensor and compensate for optional CAOM Module changes due to age, dust accumulation or other environ- • FM/UL®Listed for Pre-action/Deluge with optional mental factors. The 7100 incorporates the Gamewell-FCI MCOM Module Listed Integrated Sensitivity Testing (LIST) which meets • Periodic trouble reminder NFPA 72 sensitivity testing and maintenance requirements. • Individual sensor drift compensation The LIST testing allows substantial savings in both mainte- • Dual-stage maintenance alerts("dirty"and"very dirty") nance and service while eliminating nuisance alarms. • Multilevel sensor sensitivity adjustments(front panel The Model 7100-1D and 2D features an integral Digital programmable) Alarm Communicator Transmitter(DACT)with all popular continued on the next page transmission formats and a 16-digit telephone number An ISO 9001-2000 Company field. It is 8-digit Carrier Information Code(CIC)compliant SIGNALING NUN and also prevents"dialer-runaway" in the event of intermit- tent system faults.The 7100-1 D and 2D are UL Listed for 0 O MEA C ) ,CI LISTED "PP+O•®APPrOWd l l S1869 3003549307.93E 6911.1701-0116 I�eVMC`bYO," (rtrh Rise)Rise)== l, Miaosoff Word®is a registered trademark of Microsoft®Corporation. 307.99.E 0�1.1��ie(ip,r� vo. 4 wu►a5 agw1c UL®is a registered trademark of Underwriter's Laboratories Inc. .3Tl ll GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCl for their use. ©2012 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0466 Rev.K page 1 of 3 Description (Continued) LDM-7100 Remote Station, Proprietary, and Central Station fire alarm The LED Driver Module (LDM-7100)is designed to mount systems. It allows ample space for wiring and room for bat- in a UL Listed remote annunciator and provides outputs for • teries up to 12 A/H capacity. remote panel switches and thirty-three(33), remote LEDs. Three(3), LDM-7100 modules may be installed in a single 4*i Features (Continued) annunciator for a total of ninety-nine(99),LEDs per annun- • Alarm verification per individual sensor ciator. This combination may be repeated up to five times • Positive alarm sequence for sensors or monitor for a total of fifteen(15),LDM-7100 panels installed at up to modules five (5), different locations. Maximum distances of up to 4,000 feet (1,219 m) can be achieved using one pair of • Four levels of system access using six(6),digit pass twisted, non-shielded wire for serial communication and words with up to five(5), user passwords per Level using another pair of straight-lay wire for operating voltage. • Duplicate and extra address indications (For additional information, refer to the LDM-7100 data • March time(60 or 120 BPM)/temporal pattern/coded sheet, Part Number:9020-0519). fours/California Code/user-defined zone coding • Cross zoning • System configuration programming and 280 event log CAOM stored in non-volatile memory The Class"A"Optional Module(CAOM)allows Style Y and • Fan restart with sequential restart delay Z(Class"B" and "A") operation for both Notification Appli- • Upload/download of panel configuration between panel ance Circuits and allows Style 4 and 6(Class"B" and"A") and FCP-7100 program(password protected feature) for both Signaling Line Circuits. It also provides disconnect • Up to sixty-four(64), 7100 panels in the E3 Broadband switches for each signaling line circuit and a common dis network with an optional INI-7100 Module connect switch for both notification appliance circuits. Optional Accessories MCOM p The Municipal Connection Option Module (MCOM) pro- LCD-7100 vides three(3)choices of outputs. It can be configured as a The LCD-7100 remote serial display offers an 80-character Municipal Circuit (City Box) output. It may also be set to alphanumeric readout for the remote display of all system serve as a Reverse Polarity output with a nominal voltage events. It duplicates all the information on the 7100 Series output of 24 VDC at 0.012 amp maximum alarm and super- panel display and provides key switch protected functions visory current. The MCOM's third option provides a releas- such as System Reset, Alarm Acknowledge, Trouble ing solenoid output rated at: Acknowledge,Signal Silence,and Drill Test. • 24 VDC nominal voltage. LEDs on the LCD-7100 indicate Alarm, Supervisory, Sys- • 0.005 amp supervisory current. tem Trouble, Power Fault, Systems Silenced, NAC#1, and • 0.710 amp maximum alarm current. NAC#2 Silenced conditions. • 2 ohms maximum line resistance. The LCD-7100 can be surface or semi-flush mounted on a standard four-gang electrical box. It can be installed up to PTRM 4,000 feet(1,219 m)from the main control panel.The 7100 The Printer Transient Module (PTRM) provides RS-232 Series fire alarm control panel supports up to five (5), Isolator/Transient protection for the 7100's RS-232 port remote LCD-7100 annunciators using one pair of twisted, (BSM connector J2). It is used in conjunction with a serial non-shielded 18 AWG min. wire or serial communication printer applied to the RS-232 port for permanent record and uses another pair of 16 AWG min. for operating volt- keeping. age. (For additional information, refer to the LCD-7100 data INI-7100 sheet, Part Number:9020-0486). The Intelligent Network Interface Module allows the 7100 Series fire alarm control panel to become the platform of a RAN-7100 peer-to-peer, token ring, self-regenerative network com- The RAN-7100 maintains the same character display as prised of up to sixty-four(64), 7100 panels. the 7100 Series.The RAN-7100 is mounted in a RAN2-BB backbox for surface or flush mounting retrofits. (For additional information, refer to the Gamewell Retrofit Kits Data Sheet, P/N:9020-60678). GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 `9020-0466 Rev.K page 2 of 3 www.gamewell-fci.com Specifications Ordering Information (Continued) Primary Input Power 120 VAC,50/60 Hz @ 2.0 amps. Optional Modules Part Number Description or240 VAC,50/60 Hz @ 1.0 amp LCD-7100 Remote Serial Annunciator, LCD • Output Power 3.335 amps.@ 24 VDC(total) Display(80-character) Non-resettable Power:1.0 amp max. Dimensions: 4.25"H x 8.25"W x 1.90" Resettable Power: 1.0 amp max. (43 H x 37 W x 7.7 D cm) 1.0 amp max.from both circuits RAN-7100 Remote Series Annunciator, LCD Two(2)Notification Display(80-character) Appliance Circuits: 1.5 amp each @ 24 VDC Dimensions: 10"W x 5 1/4"H x 2 7/16" D Current: Supervisory Alarm (251/4 W x 131/3 H x 6 9/10 D cm) 7100-1 (One SLC) 0.065 amp 0.085 amp LDM-7100 Remote LED Driver Module 7100-1D 0.075 amp 0.095 amp Dimensions: 6"W x 4.50"(15.2 x 11.4 cm) (One SLC w/DACT) CAOM Class A Option Combination Module 7100-2(Two SLC) 0.065 amp 0.085 amp with disconnect switches for both 7100-2D 0.085 amp 0.105 amp signaling line circuits and notification (Two SLC w/DACT) LCD-7100 0.050 amp 0.075 amp appliance circuits LDM-7100 0.035 amp 0.200 amp MCOM Municipal Connection Option Module (All LEDs lit) for local energy city box reverse INI-7100-UTP,-FO 0.040 amp 0.040 amp polarity signaling,or releasing solenoid Operating PTRM Printer Transient Module Temperature: 32°-120°F(0°-49°C) INI-7100-FO Intelligent Network Interface Module, Fiber-Optic Relative Humidity: 93%(non-condensing) INI-7100-UTP Intelligent Network Interface Module, Battery Charger 31 A/H(Cabinet accommodates Unshielded,Twisted Pair Capacity: 12 A/H size batteries) Replacement Parts Alarm&Trouble T-7100 Transformer, 120 VAC input Relay Contacts: Form"C",2 amps. @ 24 VDC (replacement) (resistive) T-7100-240 Transformer,240 VAC input Ordering Information (replacement) BSM-7100-1 Replacement board for 7100-1 Systems BSM-7100-1D Replacement board for 7100-1D Part Number Description t' 7100-1-PNL 7100 Addressable FACP, 1 SLC Seismic Battery Bracket Kits mounted in 7100-CAB enclosure, red Part Number Description 7100-1 D-PNL 7100 Addressable FACP w/DACT, 90516 7100-Slim 7 A/H Seismic Battery Bracket kit 1 SLC mounted in 7100-CAB enclosure, red E3 B-Slim 7 A/H Seismic Battery Bracket Kit Basic Kits 90517 7100-SLim 12 A/H Seismic Battery 1100-1311 Basic System Kit,2 SLC E3 B- Kit im Kit B3 (BSM,Keypad Display,Transformer) Bracket 12 A/H Seismic Battery et Kit 1100-1312 Basic System Kit w/DACT,2 SLC 90518 NetSOLO 7100 7 A/H Seismic 1100-1313 Basic System Kit,2 SLC,240 VAC Battery Bracket Kit 1100-1314 Basic System Kit w/DACT,2 SLC, For additional information on the Seismic Battery Brackets, 240 VAC refer to the following documents: Cabinets • Seismic Battery Bracket Installation Guide, P/N: 53839 7100-CAB 7100-Slim(Narrow Enclosure,red) • E3 Series Cabinets Data Sheet, P/N: 9020-0649 14.09"W x 20.1"H x 4.55"D (35.8 W x 54.61 H x 11.55 D cm)Enclosure 1100-0480 Enclosure, E3 Series Broadband, black Enclosure, 1100-0481 E3 Series Broadband, red Dimensions: 19 3/8"H x 19 3/8"W x 4"D (49 Hx 49Wx 10Dcm) GAMEWELL-FCI 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 www.gamewell-fci.com 9020-0466 Rev.K page 3 of 3 J FIRE SYSTEM ACCESSORY Model 5495 410 SILENT Distributed Power Module KNIGHT In an emergency, • by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®,AMSECO®, Wheelock and Faraday—what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 to non-essential high-current - — Distributed Power Module accessories like magnetic door holders The 5495 is a 6 amp notification power • Built-in synchronization for expander that provides its own AC power connection, battery charging appliances from System circuit,and backup battery for use with Sensor®,Gentex®,AMSECO®, fire and security controls such as the Wheelock and Faraday Silent Knight Model 5208 Fire Control • Stand alone operation /Communicator.The 5495 is the cost- • Lightweight design adds to ease of effective solution for powering installation and reduces shipping notification appliances required by the costs Americans with Disabilities Act(ADA). Operates with most polarized, UL The 5495 has built-in ANSI cadence Listed notification devices pattern,which can upgrade older • control panels that lack cadence ANSI Cadence pattern output capability. capability built-in I� IL�1 IA\'11.111 Features Connection to Local Fire Control • UL Listed for 6 amps of notification The 5495 may be connected to a local Model 5495 fire control which utilizes Class A or power Class B • Power supply's advanced switch type notification circuits Distributed Power Module operating between 9 and 32 VDC.The mode design reduces damaging control panel's notification circuit is Approvals heat and manages power up to 50% connected to one of the inputs on the • UL Listed more efficiently than other systems 5495.The control panel's notification • MEA 429-92-E Vol XII • Dip switches allow for easy circuit end-of-line resistor is also • CSFM 7300-0559:123 reconfiguration connected across two terminals on the NFPA 72 •• 24 VDC filtered output voltage 5495,which provides supervision • Four power-limited notification between the 5495 and the fire control outputs;2 Class A or 4 Class B, or 1 panel. Polarized audible and/or visual Class A and 2 Class B notification devices are then connected • Additional continuous auxiliary to the 5495 signal circuits using the 4.7kQ end-of-line resistors provided. output Since the 5495 draws very little power • 3 amps per output circuit from the control, it is possible to • 2 inputs; 2 Class B or 2 Class A connect one 5495 to each notification • Ground fault detector/indicator circuit on the control panel and still • Independent trouble relay provide full supervision of the • AC loss delay option shuts off power notification circuits all the way back to the control panel. FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Signal 3 input Module 5495 g (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 205 mA Battery charging • Low AC power Auxiliary capacity: 35.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32° to 120° F • Earth ground fault Notification (0° to 49° C) • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25"W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble condition on the host control signal Amps per AC power on : Green circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow C trouble relay output as an 4.7 Itf2 EOL Output troubles (1-4): Yellow alternative to using the notification resistor required Ordering Information circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification AC input: 120 VAC at 2 amps No. of inputs 2 Output: 24 VDC at 6 amps Input configuration: 2 Class B or 2 Class A SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA 4re KNIGHT ke ooduct information o-dae ae W c speciep fic ur applications inf or r anticipate atup-t all requirements.tnd accurat All.spece ifications annot cover are all FORM#350395 Rev D • m subject to change without notice.For more information,contact Silent Knight ©2010 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-7161 Phone:(800)328-0103, Fax:(203)484-7118.www.silentknight.com • 1' COOPER Notification aireligrZFr Strobe, Horn Strobe, and Horn Notification Appliances • FIRE ¢ '� _ ‘1S t . _ 1.. s" u, FIRE illy _ I ' Ceiling - - - Wall Description: The Wheelock®ExcederTM Series of notification appliances feature a sleek modem design that will please building owners with reduced - Save up to 48% in current draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw,no tools needed for setting changes,voltage test - Up to 9 models now in 1 appliance points, 12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. up 14% installation** - Save u to cost of installation The Wheelock®ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single CD Sleek Modern Aesthetics appliance.Models with an audible feature 3 sound settings(90,95, • 99 dB).All switches to change settings,can be set without the use of a tool and are located behind the appliance to prevent tampering. 4 Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederT"" Series of wall and ceiling notification Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting 12/24 Multiple Voltages base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust,paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a 90,95,99 dB shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while 8 Candela Settings it is on the UMB. When the Contact Cover is removed the circuit - Wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed.The UMB allows Ceiling-15/30/60/75/95/115/150/177 for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra Universal Mounting Base *** secure installation, while the ceiling models provide a captivated Ceiling and Wall Mounts to 5 Backbox Types screw to prevent the screw from falling during installation. Compliance Environmentally Friendly • -UL 1971, UL 464, ULC, CSFM, FM Low Current Draw -ADA/NFPA/ANSI/OSHA -Rol-IS • Compatibility and Requirements -Synchronize using the Wheelock®Sync Modules or panels with built-in Wheelock®Patented Sync Protocol -Compatible with UL"Regulated Voltage"using filtered VDC or unfiltered VRMS input voltage -Strobes produce 1 flash per second over the"Regulated Voltage"range Compared to competitive models "'Patented Compared to previous models NOTE:All CAUTIONS and WARNINGS are Identified by the symbol A.All warnings are printed In bold capital lettere. A WARNING:PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING.SPECIFYING Specification&Ordering Information OR APPLYING THIS PRODUCT.VISIT W W W.COOPERNOTIFICATIONCOM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS.FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPUCATION, INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION.WHICH COULD RESULT IN PROPERTY DAMAGE,AND S nc w/ SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. y Model Strobe DSM or 12/24 UDC' Mounting General Notes: Candela Wheelock Power m Options General Notes: Supplies •Strobes are designed to Bash at 1 Bash per second minimum over their'Regulated Voltage Range'. y Horn Strobes •All candela reams represent mdNnnan effective strobe Intensity based on UL Standard 1971. N To •Senes Exceder Strobe products are listed under UL Standards 1971 end 464 for Indoor we 0th a temperature range of 32'F to 120'F(VC to 49•C)and -p HSR 15/1575/30/75/95/1101135/185 ©©15 UMB^ mwmnon homily of 93%It 2%)UL 484(85%UL 1971). 0 HSW 15/1575/30/75/95/110/135/185 X X O UMB^ Sal.S Exude,horns ere under UL Standard 484 for amide signel apolances(Indoor use ory). 0 e N HSRC 15/3080/75195/115/1501177 X X M UMB^ 0 HSWC Si 15/3080/7585/115/150/177 X X u UMB^ Low Current Draw= Fewer Power Supplies E Strobes ;° SIR N 15/1575/30/75/95/110/135/185 X X ei UMB^ Strobe Ratings per UL Standard 1971 vi STW r 15/1575/30/75/95/110/135/185 X X c UMB^ UL Max Current' E 24 VDC/24 FOUR 12 VDC N STRC CC 15/3080/7585/115/1501177 X X e UMB^c. ® Regulated VDC Voltage ®® 30 60 ®® 110 ®® 150 ®®®® O 1100 u_ 15/3080/7585/115/1501177 X X m UMB^ ® N 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 ® N NNW 10 X % A UMB^ 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0253 0.110 W CT W HNRC CO X X -. UMB^ Hom Strobe Ratings per UL 1971&Anechoic at 24 VDC HNWC _ _ - - _ x x UMB" UL Max Current'at Anechoic 99 dBA 92 VDC models feature 15 a 15/75 settings ^UMB o Universal Mounting Base 24 VDC 12 VDC CI Regulated ®® 30 60 ®® 110 ®® 150 ®®®® Model Legend / -9/* HN=Horn A=Agent Lettering 1(\1 : 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0242 0.282 0.125 0.159 ST =Strobe (Strobes only) T1• ® 8.0.33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 __ _ AL=Alert Lettering � ;� HS=Hom Strobe UL Man Current'at Anechoic 95 dBA (Strobes only) , C = Mount I ` 24 VDC 12 VDC W =White N =No Lettering �\ Regulated Voltage R =Red (Strobes only) ® R Range VDC ®® 30 60 ®m 110 ®® 150 ®®®® Example 1:STRC.Strobe.tied.Ceiling Mount / / ....0 ). ® Example 2:HSR.Hem Strobe,Red.Wag Mount f ? 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 Example 3:HSW=Hom Strobe,White,Wag Mount ® 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 Exempted:STW-AL=Strobe.White.Wall Mount.Alen Lettering Example. riExample:HSWC UL Max Current'at Anechoic 90 cIBA 24 VDC 12 VDC �- 30 60 110 150 `` ti ® 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 LL. t' r` 11 '•® 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 i u j Horn Ratings per UL Anechoic f ] ' 44./ a 11 ^ /`^/` 4 Model Regulated Voltage gg dB 95 dB 90 dB F - ` ' • Range VDC HN 16-33.0 0.064 0.044 0.022 ` •/ HNC 16-33.0 0.084 0.044 0.022 .. 1 U •UMB Contact Cov HN 8.0-17.5 0.047 0.026 0.017 t 4 .�\ i Voltage test points for quick 8 candela settings Common base for wall and ceiling with 5 HNC 8.0-17.5 0.047 0.026 0.017 `.. \\\ / troubleshooting and easy spot mounting options r�q \ `, \. checking(wall models only) \ \ / •UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units).For strobes the NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notke In accordance UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units).For audibles the max current Is usually at the with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. maximum fisted voltage(33 VDC for 24 VDC units).For unfiltered ratings,see installation instructions. • • Architects and Engineers Specifications The notification appliances shall be Wheelocke ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard - 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. • The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design. Where Multi-Candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75,95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required(e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang,4-inch square, 3.5-inch octal,4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same base among all horn, strobe, horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"W x 2.19"D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series HNC ceiling shall have a diameter of 6.68"x 1.50"D. When synchronization is required,the appliance shall be compatible with Wheelock®'s DSM Sync Modules,Wheelock®Power Supplies or other manufacturer's panels with built-in Wheelock®Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain(1) flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock®synchronization protocol. Wall Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC, FM, RoHS Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC, FM, RoHS NEM Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 5/13 NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P:800-631-2148 F:732-222-8707 www.coopernotification.com / Cooper Notification is Wheelock° I .1,3 SAFEPATH' WAV atti COOPER Notification