Loading...
Report Main Office Salem Office Bend Office P.O. Box 23814 10 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc • Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 684 -0954 FAX (503) 589 -1309 FAX (541) 330 -9163 Special Inspection FINAL SUMMARY LETTER July 12, 2004 T0405233.H City of Tigard 13125 SW Hall Blvd., Tigard, OR 97223 -8199 Attn: Building Department Re: Hawks Beard Townhomes — Lot #8 10855 SW Briarwood Place Tigard, OR Permit No.: MST2003 -00281 Dear Sir or Madam: This is to certify that in accordance with Section 1701 of the Uniform Building Code, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Installation of Adhesive Anchors All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLS'N TES IN INC. I t1 Douglas'. Lea• Chief Executive officer mbw cc: Derek L. Brown & Associates — Bruce Cone Froelich Consulting Engineers — Todd Nagle Mentrum Architecture — Bayard Metnrum 07/12/04 MON 16:33 FAX 503 684 0954 CARLSON TESTING Z003 Mein Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc • Phone (503) 684 - 3460 Phone (503) 589 - 1252 Phone (541) 330 -9155 FAX (503) 684 -0954 FAX (503) 589 -1309 FAX (541) 330 -9163 • • Special Inspection FINAL SUMMARY LETTER July 12, 2004 T0405233.H • City of Tigard 13125 SW Hall Blvd., Tigard, OR 97223 -8199 Attn: Building Department Re: Hawks Beard Townhomes — Lot #8 • 10855 SW Briarwood Place Tigard, OR Permit No.: MST2003 -00281 Dear Sir or Madam: This is to certify that in accordance with Section 1701 of the Uniform Building Code, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Installation of Adhesive Anchors All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, •the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, • CARLSoN TES IN INC. • 11,1 Douglas''. Lea • Chief Executive fficer mbw • • cc: Derek L. Brown & Associates — Bruce Cone Froelich Consulting Engineers — Todd Nagle • Mentrum Architecture — Bayard Metnrum