Loading...
Correspondence 'Pi� 11 �\ December 12, 2005 CITY OF TIGARD OREGON Bath & Body Works Tim Schenk 1120 E 80 St # 211 Bloomington, MN 55420 RE: BATH & BODY WORKS - REVIEW Project Information Building Permit: BUP2005 -00623 Construction Type:-' II -B Tenant Name: Bath & Body Works Occupancy Type: M Address: 96 3 •75"'SW Washington Sq. Occupant Load: 114 Area: 4,201 sq ft , Stories: , 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2004 International Fire Code as amended by TVF &R. The submitted plans are approved subject to the following conditions. AJ A 1. Combustible materials shall be permitted in buildings of Type I or II construction in the following Applications. OSSC 603.1 1. Fire - retardant - treated wood shall be permitted in: 1.1. Nonbearing partitions where the required fire - resistance rating is 2 hours or less. 1.2. Nonbearing exterior walls where no fire rating is required. 1.3. Roof construction as permitted in Table 601, Note c, Item 3. 2. Thermal and acoustical insulation, other than foam plastics, having a flame spread index of not more than 25. Exceptions: # that would apply (5) Interior floor finish and interior finish, trim and millwork such as doors, door frames, window sashes and frames. (6) Where not installed over 15 feet (4572 mm) above grade, show windows, nailing or furring strips, wooden bulkheads below show windows, their frames, aprons and show cases. , (7) Finished flooring applied directly to the floor slab or to wood sleepers that are fire stopped in accordance with Section 717.2.7. (8) Partitions dividing portions of stores, offices or similar places occupied by one tenant only and which do not establish a corridor serving an occupant load of 30 or more shall be permitted to be constructed of fire- retardant - treated wood, 1 -hour fire- resistance -rated construction or of wood panels or similar light construction up to 6 feet in height. Etc 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 2. Provide a privacy lock and an occupied indicator for the unisex restroom. OSSC 2902.3. 3. The main exterior door or doors are permitted to be equipped with key- operated locking devices from the egress side provided: 1. The locking device is readily distinguishable as locked, 2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background, 3. Where egress doors are used in pairs, approved automatic flush bolts shall be permitted to be used, provided that the door leaf having the automatic flush bolts has no doork nob or surface - mounted hardware. 1008.1.8.3 OSSC ' 4. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. 1011.1 OSSC 5. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1008.1.8 OSSC . 6. Exit signs shall be illuminated at all times and shall be provided with a second source of power that will provide 1 '/2 hours of illumination in case of primary power loss. 1006.3 OSSC FYI Additional exit signs may be required by the city field inspector to clearly indicate the path of egress. 7. The means of egress shall be provided, with illumination of not less than 1 foot candle at the floor level anytime the building is occupied. The means of egress illumination shall be provided with a second source of power in case of primary power loss. 1006.2 OSSC 8. Accessible checkout aisles shall be on an accessible route and at least 36 inches wide. Counters in accessible checkout aisles shall be not more than 38 inches (965 mm) high and the top of the raised edge of the counter shall not exceed 40 inches (1016 mm) in height above the finished floor. 'Accessible checkout aisles shall be identified by the international symbol of access. OSSC section 1109.19, 1109.23.3 9.Safety glazing including but not limited to: the following locations: Each unit of glazing • shall be permanently identified by the manufacturer. 2406 OSSC. Some of these locations are as follows: a. Glazing in ingress and means of egress doors. b. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24" arc of the door in a closed position and whose bottom edge is less than 60" above the floor or walking surface except when there is an intervening wall or other permanent barrier between the door and the glazing. 10. Deferred submittals such as Fire Alarm, Fire Sprinkler, Truss Joist Shop Drawings, etc, will be charged a deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee shall be $200.00. Deferred Items: a. Sprinkler system b. Awnings c. Fire alarm system 11. The racks shall display in one or more conspicuous locations a permanent plaque not less than 50 square inches in area, showing the maximum permissible unit load in clear legible print. OSSC 1603 12. Provide three 2 -A rated fire extinguisher on the storage area. The extinguisher shall be located so that no usable space has a distance greater than 75 feet to the extinguishers. OFC 906.3 13. The clearance between the deflector and the top of storage shall be 18 in. or greater. NFPA 13 8.5.6.1 American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the.applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. , Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction.106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 110.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, c:?"' Val Henzel, Senior Plans Examiner