Loading...
Permit • CITY OF TIGARD ELECTRICAL. PERMIT Oft ' ' DEVELOPMENT SERVICES PERMIT #: ELC97 -0681 ' J! 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639.4171 DATE ISSUED : 10/30/97 PARCEL: 1S136CD-CARTY SITE ADDRESS° _ ° : 11.710' SW PACIFIC HWY. , SUBDIVISION....: ZONING:C --•G BLOCK..........: LOT - ° • JURISDICTION: TIG Project Description: Electrical peroit for 5,864 sq. ft. retail building - -- RESIDENTIAL UNIT - - -- . • -- -TEMP SRVC/FEEDERS---- MISCELLANEOUS-•-- - - -••- 1000 SF OR LESS ° 0 0 - 200 amp ° 0 PUMP /IRRIGATION....: 0 EACH ADD' L 500SF° ° ° : 0 201 - 400 amp ° 0, SIGN /OUT LINE L.TG° ° : 0 LIMITED ENERGY ° 0 ' 401 - 600 amp ° 0 SIGNAL /PANEL. ° 0 MANF° HM/ SVC /FDR° ° : 0 601 +amps. - 101210 volts,: 0 MINOR LABEL (1120.....: 20 ---• -- ..SERVICE /FEEDER - -7 -- - - - -- BRANCH CIRCUITS - - - -- -- -ADD' L INSPECTIONS---- ' 0 -- 200 amp......: 0 W /SERVICE OR FEEDER: 72 PER INSPECTION ° ° ° °.: 1 201 -- 400 amp.. ° ° ° ° : 1 1st W/0 SRVC OR FDR° : 0 PER HOUR ° 0 401 - 600 amp : 0 EA ADD'!_ BRNCH CIRC: 0 IN PLANT...........: 0 601 - 1000 amp° ° ° ° ° : 0 ----- -- - -• - -- -PLAN REVIEW SECTION _�---- - - - - -- 1000+ amp /volt° ° ° ° ° : 0 > =4 RES UNITS > 600 VOLT NOMINAL..: Reconnect only.....: 0 SVC /FDR >_ 225 AMPS..: CLASS AREA /SPEC OCC.: Owner: --- •- - - - - -- --------------------- •• - - - - -- CAR TOYS type amount '.by date recpt 11710 SW PACIFIC HWY PRMT $ 440.00 JD 10/13/97 97- 300012 •TTCARD OR 97223- - PICK 1. 110.017! Jn 1/1. �0 5PCT $ 22.00 JD 10/13/97 97- 300012 Phone #: Contractor : ------------ •--- - - - - -• - _____ NEW TECH ELECTRIC • . $ 572.010 TOTAL • 1400 NE 48TH AVE . ___.-- -__ - -' RED.UIRED INSPECTIONS ----- HILLSBORO OR 97124 Ceiling Cover Underground Cove Phone *: 648 -1900 Wall Cover Elect' 1 Service Reg #. ° : 000418 This peroit is issued subject to the regulations contained in the Tigard Municipal Code, State of Oregon Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This peroit will empire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days, ATTENTION: Oregon law requires you to follow the rules adopted by . the Oregon Utility Notification Center. Those rules are set forth in OAR 952- 00i -00i0 through OAR 352 -001 -1987. You may obtain a copy of these rules or direct questions,to OUNC by calling.(503)246- 1987., Perm i.ttee Signature: �j ___ Issued By: - -• -- •- .--OWNER INSTALLATION ONLY- --- -- - - -- _____ The installation is being made on property I on which is not intended for . sale lease,- or rent. • OWNER'S SIGNATURE: ' DATE: • ------ - - - - -- ------- - - - - - -- CONTRACTOR INSTALLATION ONLY--- •----- . �.-- _. - -_. _ _._ . SIGNATURE OF SUPR. ELEC'N: AA tC AL � arN DATE: ID':.0 • • LICENSE NO: • _ _._ + + ++ + +••6•-1 ++++ ++-1 + +•i- `+ ++ +-i + +-1 + +-1 +++ ++ +-I--I-=1--1•• +++ +-14.1- -F• + ++ +-1-+-1--1--1- ++ -1--r-+ ++ +++-r-+++ ++-r--I +++ Call 639-4175 by 7:00 p° m° for an insper_t'i.'on needed the next business day ' + + + ++ +-1 + +-F•-4•_° }-I-- •-I--i--'r-i--1-+ +++-I + 1-- 1-1-4- 1--1••-I-•q•+++ +-l-i--r-++ + +, I--• + +++'..a-1- -1- -1 --I--I + ++++++-I ++++'_-i--L++ + +-1 + • CITY OF TIGARD Electrical Permit Application Plan Check # /C2 - J G C 13125 SW HALL BLVD. Recd By �7- TIGARD OR 97223 Date Recd /0 I Date to P.E. /0 I 5 Phone (503) 639 -4171, x304 Date to DST /C -- - 7 7 i'/(J' Inspection (503) 639 -4175 Print or Type Permit # i_C - - I Fax (503) 684 -7297 Incomplete or illegible will not be accepted Called /0FQ 4.- 1. Job Address: 4. Complete Fee Schedule Below: ''/ Name of Development Number of Inspections per permit allowed Name (or name of bus 7___ Service included: Items Cost Sum I Address/ 7kc7L1. f C[�.LA 408 4a. Residential - per unit Ci City/State/Zip ll" 1000 sq. ft. or less $110.00 4 H p / /��� Each additional 500 sq. ft. or Commercial Residential 1=1 Limited thereof $25.00 1 Limited Energy $25.00 Each Manuf'd Home or Modular Dwelling Service or Feeder $68.00 2 2a. Contractor installation only: (Attach copy of a}}��eurren�Ise �,,,/ 4b. Services or Feeders Electrical Contractor .f 1' Q C G C :T7 Z Installation, alteration, or relocation Address / vC l��Pi 200 amps or less $60.00 2 201 amps to 400 amps $80.00 'Z 2 ' City State C-1 Z 401 amps to 600 amps $120.00 2 Phone No. f7 � --/ qf' 601 amps to 1000 amps $180.00 2 Job No. q "7 .3 Reconnect only $50.00 2 Over 1000 amps or volts $340.00 2 Elec. Cont. Lice. No. . ' Exp.Date f di , OR State CCB Reg. No. Air - - : Exp.Date a� ( / Y 4c. Temporary Services or Feeders COT Business Tax or Metro No. Exp.Dat Installation, alteration, or relocation 200 amps or less $50.00 2 Signature of Supr. Elec'n ,Q. G 201 amps to 400 amps $75.00 2 - 401 amps to 600 amps $100.00 2 Over 600 amps to 1000 volts, / 0 License No. 3 Exp.Date /5 8 .� ' see "b" above. Phone No. C:-:4 4d. Branch Circuits New, alteration or extension per panel 2b. For owner installations: a) The fee for branch circuits with purchase of service or Print Owner's Name feeder fee. tZ2 r1�o �n Address Each branch circuit / $5.00 .77 2 b) The fee for branch circuits City State Zip without purchase of Phone No. service or feeder fee. First branch circuit $35.00 2 The installation is being made on property I own which is not Each additional branch circui $5.00 2 intended for sale, lease or rent. 4e. Miscellaneous (Service or feeder not included) Owner's Signature Each pump or irrigation circle $40.00 2 Each sign or outline lighting $40.00 2 3. Plan Review section (if required) :* Signal circuit(s) or a limited energy panel, alteration or extension $40.00 2 Minor Labels (10) $100.00 Please check appropriate item and enter fee in section 5B. 4 or more residential units in one structure 4f. Each additional inspection over V Service and feeder 225 amps or more the allowable in any of the above System over 600 volts nominal Per inspection $35.00 Classified area or structure containing special occupancy Per hour $55.00 as described in N.E.C. Chapter 5 In Plant $55.00 * Submit 2 sets of plans with application where any of the above apply. 5. Fees: Not required for temporary construction services. 5a. Enter total of above fees $ 5% Surcharge (.05 X total fees) $ VA C NOTICE Subtotal $ ' '•? • ( • 5b. Enter 25% of line 5a for /70. CO PERMITS BECOME VOID IF WORK OR CONSTRUCTION AUTHORIZED IS Plan Review if required (Sec.3) $ NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK Subtotal $ IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. ❑ Trust Account # $ Total balance Due I: \OSTS \ELC96 APP Rev 9/96 . 1 1 . N I Post -itr Fax Note 7871 Oath of co T.o � * r0 - /0"12 IPages Z . ;••M l]�* ; v From Co.iQopt T 9 Phone 0... EI c c • ytij, Co. ca - Ccc�n £�� 1 (Ar F „ • Phone # F iv 6Y 1100 o -- - -- - - -- Fax n b y O O S 7 I 0 • y r 01 0 . � 0 N_TI~4 0 y I. PROVIDE AN ADa1TIONR4L PANEL IF ~ MORE OIRCU=T BREAKERS ATE NEEDED. WWI C.T. ENCLOSURE 2. ALL ELECTRICAL COMPOttEJ4TS SHALL HAVE (S 2E PER PO op.) � A RATING of 1Q.c0o AIC OR THE VALUE OF THE A1AR.eBLE FAULT CURRENT IF GREATER. 7 t» CT. RATED METER SOCKET �" �_ y (PER POWER CO..) - / CT5 n, r e: TO NF '7 NEI►f41 VAREWSY. (LENGTH AS RETTL RED) METALLIC WATER -go CA E U G. TO LOC;ATIQN LINE. 3/4' PVC X 10' C 1). ROD ENCASED IN CRI CON MIMED 8Y LOCAL 41,./D . G BARE COPPER. 7_100, � �I.E. REQPR AS REQUIRED ROO N SED 250-60 O POKR CO. (OOOPE/IRATE- ALL WORK) 208V /120V.. 3t8, ePN. / 4'C,- 4-5DDhICM CU., THWN - 1 Pte —I2�COP 2 --11-- .aae it w CAR Tan'. (flCND) COMPANY NAME $ERVI RriF DIAGRAM AD? EN :INFERS KT.S. I1 0 0 r Service Load Calculation 1� V Job Name: Car Toys (Tigard) Company Name: AER Engineers Non - continuous Load: Date: 10122/97 Duplex Recept. 61 X 180 watts 4 -Pfex Recap/. 10980 watts 3 X 380 watts = 1080 watts Total watt= 12060 watts 10,000watts ©100% Rest at 80% 10000 watts 1648 watts Total recept. load = 11648 watts Cooking Load 0 watts Motor Load = 0 watts Lighting Load: interior Neon 76 amps 120 V = l:.rtercr Wall Packs 9120 watts d+rior Neon 300 watts 20 amps 120 V = 2400 watts Pole Siyn 32 amps 120 V c Track Lighting(2R sections) 43 s 3840 watts sections 150 watts 6450 watts Plourescent & Incandes. Exterior lighting (recessed cans) 9830 watts E��Itiamerg, 400 watts Pule light watts 350 Mgt Total lighting Load = 33230 watts Continuous Loads: Microwave Coffee maker 500 watts Water Heater 1000 watts 16 amps 120 V = 1920 watts tea. O.H. door Motors 40 amps 120 V = Refrigerator 16 watts 16 amps 120 V = 1920 watts Looms 1.2,3, R exotic (16A ea,) 64 amps 120 V = .1 cm. 5ton Unit ( ,SA 7680 watts 46.5 amps 208 V = 9672 watts 2 ea. 4ton Units (@38.3A) 72.6 anps 208 V Restroom Exhaust fans 15100.8 watts 2.6 amps 120 V = 312 watts Table Saw 20 amps 208 V Oust Cotlectflr 4160 watts 20 amps 208 V = 4160 watts Compressor 30 amps 208 V Spay Booth 16 watts 16 amps 120 V = 1920 wits Total Continuous Load = 42504.8 watts Continuous Load + Lighting = 75734.8 watts Continuous Load + Lighting x 1.25 (125%) = 94668.5 watts Miscellaneous = 21590 watts Total Non - continuous Load = 11648 viatta Total watts for new service = 127906.5 watts Total amps (208V, 3phass) = 355 Arms 200 D313 HD3I Af3�\ TLSO O179 COS XVd 00 : ZT «3M L6 /lli i •. I Pos1.11" bran fax Uansmittal me.i MI =_ 1 I I - � (a C ,-I In / Art • ` rem era) .` - '� I . - �{/OOq �1 A6 I - fMi7�./a`i 9S O.r r� • �i y Po. F —+ _ .../... Co :%=lrr i I. /1. /soI' ✓ d iM - WRIk aro 1 • ro z N I _ r : A R . ° � •(� E�r r AMP 56 - NEIL AL 441114111 • W 7fLp— • . 1 - . . i r 1L441C 191,1111211100 ..4, - - . •:. . . . .- - .... iiirital!ftft%or Dtt GnI1 I . . 4 's \ \ 1 v; . .. ioyk() 'r 11 * r • . \\\‘ 405 04,0 • T 4* N.) . �. P1' Aaats.. cam:' T°•, -� • \ • Q �7/lLl l rrf+1WM R4svTM I a, L %IC EN_c � ► de. y 5 -a'1 ' Y Pio� c'atl F $ � \ p oN .r 1 ri A 1 00 MP ce b . v LIQ5llO,1S• S . tbie . �� , 3 rao \ 1 "774 41 T �J•� \ • Araks - Tee � ti _ '. P44 ww .tifgr t.) 15rAt41,0;uz, o / .\ . I .5 la VD 4 � . . r te `�•� 1a'�c� 150 -- - . —e ' . l''�1 r w 4 �rK,�,� '•e -fir °� n r • 1. ` z p�,�a ?' : p JD '1 7 w , (0 ‘111 - �aTb, s D -e• \ ' : ci., _, ._.. "iireiii4471(7:1 \- --=- , ...,_„____-„, .i , § .0, 4 "72_00 • JOLT '- • w N o Ill 0 ii+DM 75 '�� � sad wYE f1\15171 LL- f- „• AL ri I F i c OF- 7_ c y Zb = PAky CMST - sLNEDuLe NO PVC, . r m cn c r� IN (uST `1 SCNt =0u1 E yV A` ���� / E ic cJnl A 9 c Frf S °fy.. /� In I -- .i a 0 ti N N . 0 1 •••• Page No. 1 CASE HISTORY FOR CASE NO.: ELC97 -0681 CAR TOYS 11710 SW PACIFIC HWY 06/17/98 Action Description Reg/ Schd/ find/ Action Notes Disp By Update Upd Code Sent Done Done Date By ELCC001 Application received / / / / 10/13/97 RECD JD 10/15/97 BON ELCC003 Permit created / / / / 10/15/97 DONE B 10/15/97 BON ELCC102 Plans routed to Plans Examiner / / / / 10/15/97 SENT B 10/15/97 BON ELCC110 Plans checked /approved by P.E. / / / / 10/23/97 PASS MJR 10/28/97 MJR ELCC115 Approved plans routed to DSTs / / / / 10/23/97 SENT MJR 10/28/97 MJR ELCC400 (F)Ready to issue / / / / 10/29/97 PASS JSD 10/29/97 JD ELCC500 (F)Issue permit / / / / 10/30/97 PASS B 10/30/97 BON ELCC700 Ceiling Cover / / / / 11/10/97 souffet area PASS MJR 11/12/97 MJR ELCC700 Ceiling Cover / / / / 12/01/97 PASS BRP 12/01/97 MJR ELCC700 Ceiling Cover / / / / 11/26/97 Main entry, sales area ok ceiling PART BRP 12/04/97 J *H ELCC720 Wall Cover / / / / 11/03/97 shop area only PASS MJR 11/03/97 MJR ELCC720 Wall Cover / / / / 11/06/97 PASS MJR 11/06/97 MJR ELCC725 Underground Cover / / / / 10/29/97 courtesy inspection - UG slab PASS MJR 10/29/97 J *H approved /underground cover. ELCC730 Elect'l Service / / / / 11/17/97 PASS MJR 11/17/97 MJR ELCC799 Elect'l Final / / / / 12/02/97 PASS BRP 12/04/97 J *H ELCC800 Case Finaled / / / / 12/02/97 PASS BRP 12/04/97 J *H