Specifications fj°52oI I - E7 H �'° e�i "' ly N5 /0S "''' .y 5.y ste m s Scope of work to Upgrade Fire Alarm System April 25, 2011 PACF1C GARDENS 14145 SW 105 ST TIGARD OR. 97224 The scope of work for this fire alarm system project is to replace the existing defective class B fire alarm control panel, and upgrade the system to meet current NFPA 72 requirements. The existing system will be replaced with the following devices: 1- Silent Knight 5820XL Addressable Fire alarm Control \Communicator 1- Silent Knight 5860 LCD Remote Control\Annunciator 71- SK Addressable smoke detectors 35- SK Addressable smoke detector bases 43- SK Addressable relay smoke detector bases 16- System Sensor Fire alarm Chime Strobes 9- System Sensor Fire Alarm Strobes 4- Silent Knight Addressable Fire Alarm Manual Pullstations 7- Silent Knight Addressable Fire Alarm heat detectors (ROR) As necessary relay modules, conduit, wiring, backboxes and labor to complete this project. Please see notes on the installation of these devices Don Hegge - President Hi -Tech Systems Date 512 NW Carty Rd., Ridgefield, WA 98642 ph: 360/887 -7062 fax: 360/887 -7065 • i.� 1 -T e�/ • Sy ste m s Notes for Upgrade to Fire Alarm System • April 25, 2011 PACFIC GARDENS 14145 SW 105 ST TIGARD OR. 97224 1. All patient room smoke detectors will be replaced with an SK Photo smoke detector including an SK B224RB relay base. This replacement smoke detector will be wired to the associated hallway fire alarm indicator light. 2. The existing fire alarm annunciator located at the nursing station will be replaced with an SK 5860 remote annunciator. 3. All fire alarm system alarm bells will be replaced with System sensor Chime \Strobes or Strobes. These will be synchronized. Please see fire alarm system plan for these device locations. 4. All existing fire alarm system manual pullstations will be replaced with SK —Pull — SA pullstations. Please see the fire alarm system plan for these locations. 5. The existing fire alarm system smoke detectors in corridors and common areas will be replaced and relocated with SK Photo Smoke detectors. Please see fire alarm plan for these locations. 6. All existing fire sprinkler system devices will be wired to the new fire alarm control panel and addressed individually. 7. All existing fire alarm system relay functions, such as fire door holder release and door lock release will be wired to and programmed for proper operation by the SK 5820XL control panel. 8. This fire alarm system has an automatic emergency generator installed, battery calculations will be based on 24 hour battery backup calculations. 9. All new fire alarm system wiring will be FPL 18 gauge. 10. Existing FPL 18 gauge wiring will be utilized where practical. 11. All wiring and devices will be installed to meet current NFPA 70, and 72 requirements. 12. The existing Resident Room Hallway fire alarm annunciator lights and wiring will be wired to each corresponding smoke detector to light when that smoke detector is in alarm utilizing control panel power and the addressable relay at the detector. 13. The UL Listed monitoring will be provided by the onboard dialer of the 5820x1 panel. Don Hegge - President Hi-Tech Systems 512 NW Carty Rd., Ridgefield, WA 98642 ph: 360/887 -7062 fax: 360/887 -7065 NOTICE OF CONSTRUCTION PLANS APPROVAL FACILITIES, PLANNING & SAFETY OREGON HEALTH AUTHORITY - PUBLIC HEALTH DI qq • of Community n 1 i( Office o C ty Health and Health Planni (For projects to be licensed by Health Care Regulation & Quality Idh 2r' r ettqnt or Seniors and People with Disabilities) CITY OF TIGARD FACILITY: PACIFIC GARDENS HEALTH & REHAB B % D sipp PROJECT: REPLACE CLASS B FIRE ALARM SYSTEM ADDRESS: 14145 SW 105 TH ST., TIGARD, OREGON 97224 This Notice is intended to inform the project sponsor, architect and licensing agency that construction plans for the above noted project have been reviewed and approved by Facilities Planning & Safety. Further agency comments, if any, regarding the proposed methods for corrections are noted below. Approval of submitted plans is not an approval of omissions or oversights by this agency or of non - compliance with any applicable rules, regulations or codes. Please find attached a copy of our Project Substantial Completion Notice form which needs to be completed and sent to those agencies listed on the fonm. This needs to be done approximately three weeks prior to the intended occupancy of the project area. AGENCY COMMENTS, IF ANY, REGARDING PLAN REVIEW RESPONSES AND PROPOSED PLAN OF CORRECTIONS: There were no plan review comments. t I June 22, 2011 Approved i y: rcy E. Renfrow Date ` .i FACILITIES PLANNING & SAFETY cc: /Don Hegge Dan Jones, Oregon State Deputy Fire Marshal Mark Vandomelen, City of Tigard Building Official Dave Allm, SENIORS & PEOPLE WITH DISABILITIES y;(4 L..01 C i v j-l 5 - 6 31- -i / I: \Health Services \Pacific Gardens Hlth & Rehab - Tigard \11 -67 Replace Class B Fire Alain System \6.22. I I MER- ConstPlanApprvl I l l I - 67.docx PROJECT SUBSTANTIAL COMPLETION NOTICE Nursing Homes, Assisted Living Facilities and Residential Care Facilities INSTRUCTIONS: • Complete and forward this report approximately three weeks prior to receiving an Occupancy Permit from the Authority Having Jurisdiction. • Coordinate the actual inspection date and time with staff at Facilities Planning and Safety. • Patient/Resident occupancy should not take place until the Site Inspection has been completed, all Inspection items resolved, a Project Building Approval is issued from Facilities Planning and Safety and appropriate documents are completed for Seniors & People with Disabilities. For further information, please call 503- 373 -7201. Copies should be provided and forwarded as follows: For ALL projects, FORWARD ONE COPY TO: For ALL projects, FORWARD ONE COPY TO: Pamela Triplett The City, County or State Building FACILITIES PLANNING & SAFETY Codes Agency which issued the Oregon Health Authority - Public Health Building Permit for the project. 880 Winter Street, NE Salem, OR 97301 FAX: 503- 373 -0313 For NURSING HOMES For RESIDENTIAL CARE FACILITIES FORWARD ONE COPY TO: FORWARD ONE COPY TO: Dave Allm Residential Care Program LICENSING & QUALITY OF CARE LICENSING & QUALITY OF CARE Seniors & People with Disabilities Seniors & People with Disabilities 500 Summer Street, NE, (E -13) 500 Summer Street, NE, (E -13) Salem OR 97310 Salem OR 97310 FAX: 503 -378 -8966 FAX: 503 - 378 -8966 For ASSISTED LIVING FACILITIES FORWARD ONE COPY TO THE STATE FIRE FORWARD ONE COPY TO: MARSHAL'S OFFICE: Assisted Living Program Gayle Johnson LICENSING & QUALITY OF CARE FIRE & LIFE SAFETY SERVICE UNIT Seniors & People with Disabilities Office of State Fire Marshal 500 Summer Street, NE, (E -13) 4760 Portland Road, NE Salem OR 97310 Salem OR 97305 FAX: 503- 378 -8966 FAX: 503- 373 -1825 PLANS REVIEW #: PR #: FACILITY NAME: PROJECT DESCRIPTION: ADDRESS: , FACILITY CONTACT PERSON: ADDRESS: TELEPHONE NO: FAX No: E -MAIL ADDRESS: DESIRED INSPECTION DATE: EXPECTED OCCUPANCY DATE: I: \Health Scrvices\3 - THE WALL DOCUMENTS13 MISCELLANEOUS 6. 20. 08\( 6)- ProjSubstCompl- NursliomesResidFacAsstdLivFac- Word.doc - _ 3 '7 3 -- 7 I PR -1 FORM enni 7 i PZ ` e TT - • PLAN REVIEW INPUT FORM (OAR 333 - 675 -0000 through 333 - 675 -0040) . • (To be submitted with Schematic. Drawings andFinal Construction Documents) / '1 � n 1. Facility Name: �� 1' I �.7 91 � n ' .a42-i ) c i e!: i2e_. ' 2. a. Project Description: 1 A d... 1 'L . . _ r� 1 :rte S y/ `j b. (IBC) Occupancy Classification: T. c. (IBC) Construction Type: S j : t'rG l.. 0 d. Bed Count Alterations: f v" f�R �� ° ° 1 3. Project Address,.City & Zip:r���in 4. Local Building Codes Jurisdiction City or County): Q. i r 1 5. State Deputy Fire Marshal Jurisdiction: i q 6. Date of Submission: R a (, 1 ' I ( 7. Type of Review* Requested: Schematic Documents Construction Documents Project Type, Size and Estimated Costs . 8. New Construction *9.Existing Building Conversion 10. Existing Building Remodel Sq. Ft. Sq. Ft. Sq. Ft. 30, (0 0 0 Cost /Sq. Ft. $ Cost /Sq. Ft. $ New Constr Building Value Remodel SUBTOTAL ) $ SUBTOTAL $ SUBTOTAL $a � ) i �� . TOTAL PROJECT COST . #8, #9 & #10 Total) $ *Conversions are reviewed from plans of both the existing building and renovation plans. Review fees a : based on the tax assessed value of the existing structure (or prorated part of a structure if not all to be converted) and estimated . remodel costs. p r 1 1. PROJECT SPONSOR'S NAME: DO , 4 t e_C5C E? i . Project Contact Person (if different from sponsor's name): . Address: ,l IA P T D TS_ ..1 qtra fl i 7 / ' . 1 - , • L ii Co41 X Phone Number: _ ' Ji - • , ' Z. FAX Number: " c' :& ) Co 5 E -mail Address: f!) N l�e`S5 c C '� ii C' . ;1 ,, f1 a - 12. ARCHITECT /ENGINEER: a' name- -� Contact Person: � ' r , `� Address: 1 0 A 1 .wr ' .. . a g $ vi r• � , u 6)4/ �- Add Phone Number: ���� f Pax umber: _ _ E -Mail Address: P fl Al /4 . f3(5, 6,%e.) e6 1 ., t/ e i 13. FEES a. SCHEMATIC DOCUMENT REVIEW FEE INCLUDED. (One -third of total )/ review fee indicated on Table I of OAR 333 - 675- 0050,and based on initial $ construction cost estimate): b. FINAL CONSTRUCTION DOCUMENT REVIEW FEE INCLUDED. J OO (Per Table I of OAR 333 - 675 -0050 minus any amount previously submitted for 3 schematic review and based on bids or the latest revised construction cost estimate): $ c. TOTAL REVIEW FEE S UBMITTED: $ I . (Checks must be submitted at the time of plan submission.) Please Make Checks Payable to: OCHHP, FACILITIES PLANNING AND SAFETY Facilities Planning &Safety's address is: 880 WINTER STREET, NE, SALEM, OREGON 97301 Page 2 of 2 • I Li ILI5 105 FP5 o - 0 F 7 it SILENT IntelliKnight Model 5820XL KNIGHT Addressable Fire 0 Alarm Control System by Honeywell The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built -in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800- 328 -0103. Description ,-,,, i - - i: 5820XL is an intelligent addressable fire alarm control panel (FACP). . The basic 5820XL system can be expanded by adding modules such as I 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 — 1 1 serial /parallel printer interface module (for printing system reports), and �= : . ®:: .► 5895XL intelligent power module. 5820XL supports Hochiki or SK devices. . 5820XL also features a powerful built -in dual line fire communicator that - _ _ _ . - o allows for reporting of all system activity to a remote monitoring location. Features I ' • Built in support for 99 SK detectors and 99 SK modules, expandable to i! ' 396 SK detectors and 396 SK modules using System Sensor protocol • Built in support for 127 Hochiki devices, expandable to 508 Hochiki i devices using Hochiki protocol. • Uses standard wire —no shielded or twisted pair required j • Built -in digital communicator i • Central station reporting by point or by zone I , �,,, • Built -in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® • FlexputTM I/O circuits Model 5820XL • Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits • Distributed, intelligent power Installation • Drift compensation The 5820XL can be surface or flush mounted • 13 pre - programmed output cadences (including ANSI -3.41) and 4 Compatibility programmable outputs The 5820XL SLC supports multiple device • Built -in annunciator with 80- character LCD display types of the same protocol: • RS -485 bus provides communication to system accessories SK (System Sensor) • • Built -in RS -232 and USB interface for programming via PC • Built -in Form C trouble relay rated at 2.5 amps at 27.4 VDC • Hochiki • Improvements in SKSS software deliver five times faster You cannot mix Hochiki and SK devices on a uploads /downloads FACP. • Two built -in Form C programmable relays rated at 2.5 amps at 27.4 VDC • Supports sounder bases • • 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) • Programmable date setting for Daylight Saving Time • Plex -1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions • IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system. The General Alarm (Red): Flashes when in and maximum battery charging built -in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours. An additional annunciator give on -site access to all cabinet enclosure (PN RBB) is required programming. You can also program Supervisory (Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite, which is Windows® - supervisory silenced be individually programmed to function based software. System Troubles (Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs, or initiation circuits that when trouble silenced support both 2- and 4 -wire smoke Built - Digital Communicator detectors. 5820XL features a built-in UL listed System Silenced (Yellow): On when an The 5820XL system operates on non- digital communicator for remote alarm, trouble or supervisory condition reporting of system activity and system has been silenced but not yet cleared twisted, unshielded cable when wired in compliance with standard wiring programming. The communicator has System Power (Green): Flashes for AC practices as called out in the National the ability to seize two telephone lines failure; solid when power systems are Electric Code 760 -51 specifications for to report alarms and troubles to a normal power - limited fire protective signalling monitoring facility. The communicator cables. No special wiring is required. supervises two phone lines and will System Application 5820XL provides 13 preset notification activate a trouble signal if a line failure 5820XL has one built -in signalling line cadence patterns (including ANSI 3.41) is sustained for more than 45 seconds. circuit (SLC) which supports multiple and four user programmable selections Other communication features include: devices dependent on protocol being for fire alarm notification. retry if communication fails, two phone used. Three additional loops can be Two programmable general purpose number capability, download phone added using the 5815XL SLC Form C relay outputs are provided on numy capability and Touch -Tone or dialing. expanders to increase overall capacity. 5820XL, rotary dling. The communicator is Additionally, the IntelliKnight system compatible with SIA and Ademco Cont • The 5820XL SLC loops support features a built -in walk test and auto- acco unt ID. The format is selectable by multiple device types, including: programming. Its innovative, dead -front account number. • Addressable photoelectric smoke cabinet design allows for flush or detector surface mounting. System maintenance w to " �" ""' is eas • Addressable ionization smoke easy o perform. detector u ,, , User Interface . �--� ;:, 1 • Addressable heat sensor . ,,,rt•••r The 5820XL built -in annunciator with • • Addressable duct smoke detector 80 character LCD display and large '� • Contact module easy -to -use tactile touchpad can be ' la 0' • { U WI • Relay output module used for system operation, gia atm tr , , programming and maintenance. It has r , I _ ' • Addressable notification module five LEDs for alarm, i ! • Addressable beam detector (SK system trouble, system silenced and '� ° �' protocol only) system power. System operations • Addressable multi- criteria smoke include silencing alarms and troubles, resetting alarms and the display of Approvals detector (SK protocol only) NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory. The • Addressable multi modules (SK system's non - volatile event history NFPA 72: Central Station; Remote • protocol only) buffer stores 1000 events for viewing Signalling; Local Protective Signalling from the built -in or remote annunciator. Systems; Auxiliary Protected Premises The following advanced sensor Unit; & Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with a mechanical firefighter's key or a valid Service. Suitable for automatic, • • Automatic drift compensation 4- to 7 -digit operator's code. manual, waterflow, sprinkler • Maintenance alert supervisory (DACT non - coded) • Built-in sensor test to comply with Programming signalling services. NFPA 72 calibration testing The IntelliKnight system offers several Other Approvals: UL Listed; requirements options to simplify and speed up CSFM 7170 -0559: 135; programming. The JumpStart® feature MEA 429 -92 -E Vol. VI; FM Approved minimizes programming • . • - - " - , • ' - • • , I IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel IntelliKnight 5820XL Addressable Fire Alarm System larrAy hionaueavonl Scat.. SK (System Sensor) Protocol Devices M,00..% Basta 1.9/Doosausa sedum. -•-i--+ ,.4 , • ( .i 7 ' Compatible CS ■1..epoici je elo i m I Receiver •••si.oir di • - . ...mow,. SoNala I r= .. k-, _____Ip. 1411111100 l' . 5820XL SK-212UD — - • I ' IP Communicator I I I '': MS Internot Connection VisorAlarm 5895XL Wet 000 Pura 41000a . '... ::: , ■ 3 ram C R ways r , ■ . . . _ 1 ,, 3 Lam C Relays j • . e. . . • 1 . E l ulf.ter I I .. ..f... . . . .: 5815XL 1 .' • MI 5860 5824 li.ii j I , . ."--•• ' . • ,,c e* 1- • Rem. MritinelAILK Rimer/Gateway wow. i; :inn UasZylarn) ' ... 6 Floxput " I I I/O Circuits H • • . '."' t015XL BAC E Rum.. ti con be inputs t . I Of outpum '...: • 6 Flooput" o 5 _ iro Circuits r; a , . F can be inputs 01 outputs 8 I' '•'• • IC) R 1 4 .... • ,..; De.. Orcroos lionts. ana N.ACs . ....r..L_:1 - _,i ./ •A . .-' ill NOV -........ 2 no zoom, co.....amo s.11:e. c• Brum Dwircla s • V I L I I I • "--g 1...'lr' . _ - ......' .'.. td o ',„, i • -t.. '.':-: . . I I I I I I • 1... .--- -• =minim 5K-Ion SK-Monitot 5K-Photo 5K-Control B200SR SK-Heat SK-Zone-6 .::. *00 .1000. Aliessaue areuulyelle Bupenusm Bynou, 007.0.01, 10,, Mtalial lAresta 4.41.4 PRaturiattuu Gumbo Mcgait B.,. 11.1 a... DalKtea Deir.dor Damao mmv. 5860 I I I I Rum.. Antsursemo -1.• L L.t. kit < , . -7- 7 r g.'-"-.. • .._„ .,...--,...LJ h. —.. ,...... .,': • , i' , , : ..,..-. , - A - 9., , 7 I SK-Photo-T SK-Control-8 SK-Heat-ROR 8224R8 8224131 13210LP 0400.0.0. 4.rn.b. ...Sat. any Isolator 00e00 6880 Prutcrehonc 1.0.1c0001 ru.o2,1e Ram-at. Rise Diu Base Rau [ LED DO. I 0.17010 .00orrniri Dual. datecto MU MOtIG 11 i I I I I I I Or I X IN Ts kf r ---7- ' 2. • .„ -..- Nh,... - age L . , 111 -- l ' •,,,, , 11 - ---- - .1111lUillill! 1 I I I 5883 Raluy Ir dada. M.A. SK-I3eam 5K-Mon-10 SK-Hoot-HT 5K•Pull-DA SK-Duct SK.Minimon 5K-Relay-6 SK-loo 5X.B 000.1N1000 hbena• ktri linat ...mu!. Me.. Re% u Corm , au I lydalu U01.00 ...... 0.00 TerRy PO 021crl Uun (Men. m.uhr Mo... 000001. .7r138.. • • Neal Ocluzus Beam Deacto CI UMMMI 5865-4 or 68663 I I LED !mandato Use the 5860 to control up to 4 i_ _ _, tmos4 mo.ni 5863 Relay Interface Modules 1 I 'IV _1 IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications S -BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz, 2.5A or LCD display keypad and firefighter's User - friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power - limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current: 215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support Powerful end -user facility management Six programmable circuits which can be 127 devices. software allows viewing of detector programmed individually as: 5895XL Intelligent Power Module status and event history via modem or Notification circuits: 3A @ 27.4 VDC Adds 6 amps of power, 6 Flexput I/O direct connection. per circuit, power - limited circuits and 2 Form C relay circuits to a Plex -1 Auxiliary power circuits: 3A @ 27.4VDC 5820XL system. Dead front cabinet door with clear per circuit, power - limited 5496 Intelligent Power Module window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC A 6 amp notification power expander RBB per circuit, power limited that provides four power - limited notifi- Remote battery box accessory cabinet. cation appliance circuit outputs. Use if backup batteries are too large to Physical 5880 LED/I0 Module fit into FACP cabinet. Dimensions: Flush Mount Dimensions: Features 40 LED outputs, 8 normally 16" W x 10" H x 6" D 14.5 "W x 24.75 "H x 3.9 "D open dry contact inputs, and one piezo (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm) output. SD505 -DTS -K 5865 -3 and 5865 -4 Remote test switch. Used with Overall Dimensions: Remote LED Annunciator SD505- DUCTR. Provides remote key 16.2 "W x 26.4 "H x 4.2 "D Features 30 programmable LED (15 operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) red and 15 yellow) outputs, and a piezo of detector alarm. sounder. The 5865 -4 adds a silence Hochiki and SK Devices " Weight: 28 lbs. (12.8 kg) and reset switch to the package. See the specification sheets listed 5883 Relay Board below for a complete listing of the Color: Red Features 10 general purpose Form C Hochiki and SK devices. relays. Used with 5880 module. 53624 Hochiki Devices Data Sheet Battery Charging Capacity: 7.0 -35 AH 5824 Serial /Parallel Printer 53623 SK Device Protocol Devices Interface Module Specification Sheet Battery Size: 18 AH max allowed in Provides one parallel and one RS -232 control panel cabinet. Larger capacity serial port for connecting a printer to batteries can be housed in RBB the 5820XL. Use to print a real -time log accessory cabinet. of system events, detector status reports, and event history. Interfaces Telephone Requirements: with building control system. FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) SILENT This document is not intended to be used for installation purposes. We try to keep our product N KNIGHT information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, Made in America contact Silent Knight 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484 -7161, PN 350210 Rev G by Honeywell Fax: (203) 484 -7118. www.silentknight.com. © 2010 Honeywell International Inc. IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight Iti SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy -to -use interface found on the IntelliKnight panel's built -in annunciator. The 80- character display and ergonomically designed keypad allow for simple and error -free system operation. All operations — including reset, silence, detector status checking, fire drill, and programming —are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS -485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1 -800- 328 -0103. Description p multiple 5860s Features include an 80- character • RS -485 interface to panel backlit LCD providing easy -to- • Operation and appearance is ' - • • . understand system messages. The identical to 5860 built -in ` annunciator is ergonomically annunciator . designed with over -sized buttons • On -board piezo sounder audibly a< a L.3: for the most frequently used indicates alarms, troubles, and c.0 Lx fiy ,4 • features, like Reset and Silence. supervisories I ki tio u 7 et In addition to status messages •Five status LEDs for alarm,, y o, • displayed on the LCD, there are supervisory, trouble, silence and AC power conditions five LEDs for alarm, supervisory, • Wiring lengths up to 6000 ft. from • trouble, silence, and AC power the FACP (depending on wire status. gauge and number of devices on 5860 The annunciator is available in gray SBUS) Environmental to match virtually any decor and • UL listed, complies with NFPA 72 Operating Temperature: 32 °F – red for applications where the • CSFM approved 120 °F (0 °C – 49 °C) annunciator must stand out. The Electrical Specifications Humidity: 10% – 93% non - annunciator enclosure can be Operating Voltage: 24 VDC condensing surface or flush mounted. A trim Standby Current: 20 mA max Compatibility ring kit is available for surface The 5860 is compatible is the mounting. Alarm Current: 25 mA following FACP's: Wiring Distance: 6,000 max. from • Features FACP (depending on wire gauge IntelliKnight 5820XL FACP • 80- character backlit LCD display and number of devices on the • IntelliKnight 5808 FACP (4 lines with 20 characters on SBUS) IntelliKnight 5700 FACP each line) ) • 9 • Tactile and audible feedback Max Per System: 8 Approvals /Listings • Accepts user codes or fire Mechanical Specifications NFPA 72; UL Listed; fighter's key CSFM 7170 -0559: 135; Physical 9.1 "Wx7.4 "Hx 1.5 "D • Larger keypad buttons for system (23.1 W x 18.8 H x 3.8 D cm) MEA 429 -92 -E Vol. IX; reset and silence FM Approved • Install up to eight 5860s per Shipping Weight: 2.8 lbs (1.3 kg) FACP Color • Available in red or light gray 5860R: Red 5860: Gray • Support for simultaneous use of 5860 Remote Annunciator . Engineering Specifications The main control must have a built -in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built -in annunciator. Remote annunciators shall be available in two colors, red or light gray. must Remot a an 80-character LCD display and must feature operation as for:tGbuilt-in annunciators General ralAla Alarm, Supervisory, System must have an 80 -cha a Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP l _ "'' -0 .-..7.— f� • ' L1 . -: - ® — .7:7 MGN � O YV Y�I�U pVa I �ayVQ t+ ■ VYV Ca uuv klo� I wow IQ W. I SBUS v 441...9 4 _ w. i sauv, 71,1Z �: t�, < — • 5860 5860 5860 Up to Eight 5860s Per System Compatible IntelliKnight FACP Ordering Information 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red. 5860 Remote Annunciator.Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. - 5860TG Gray Trim Ring for surface mounting. SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA KNIGHT to keep our product information up -to -date and accurate. We cannot cover E 44 Rev 2 5 3024 v all specific applications or anticipate all requirements. All specifications are © 2010 FORM# RM# 3 5 0 I R e v E Inc. subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472 -1610. Phone: (800) 328 -0103, Fax: (203) 484 -7118. www.silentknight.com ,, .4, SD- 505 -6RB a ' 6" Relay Base ..J. y4 •+ �y� y r - .,� . i ,;. .'1 Add a relay output to an addressable •: , .+ . detector with Silent Knight's SD505 -6RB. 90 The SD505 -6RB adds a relay output function to an addressable detector. I • Providing one Form C contact rated at 8.0 amps for 240 VAC, 120 VAC ' :.`i. ; °+ 1- .1 " and 30 VDC. The SD500 -6RB allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. The SD500 -6RB is compact and mounts in an extension base that is compatible with the SD505 -APS, SD505 -AIS, or SD505 -AHS. Combine this with the features you've come to expect from Silent Knight fire protection devices —easy installation and stable operation —and it adds up to a flexible solution for all your fire protection needs. For more information about the SD505 -6RB, or to locate your nearest source, please call 1 -8 00- 446 -6444, or in Minnesota, call 7 63 - 493 -6435. Description Specifications The SD505 -6RB provides one Form C Relay atin Compatible Devices contact rated at 8.0 amps for 240 VAC, y g SD505 -APS 120 VAC and 30 VDC. The contact can 8.0A @ 240/120 0 VAC SD505 -AIS be used for virtually any normally open SLC Current Draw: 0.082 mA SD505-AHS or normally closed application. Max. SLC Loop Resistance: 50 0 Approvals Operation Dimensions: Each relay module is programmed with 6.9" W x 4.25" H x 1" D UL Listed a unique SLC loop address. When an 14.46 cm W x 10.79 cm H x 2.54 cm D CSFM Listed event that controls the relay module Operating Temp: occurs, the relay is triggered by the 32° to 120° F (0° to 49° C) IntelliKnight panel. Maximum Wiring Distance:1000 ft Features • Adds an 8.0 A relay output to an an addressable detector • Fully supervised -�. • Can be used with either style 4 or p r • � .: �. M 'MIME r•- - style 6 supervision. �.h '' • Mounts to a standard single or . I k ,..• - -. : 1 --. '4.. double gang electrical box. ; !' 4, `r Y , g I i • UL Listed r:. m a • Adds relay output without using ti..' _" ' t,. °_ ° another SLC addresses �, 1 • '� f fti SILENT KNIGHT Model SD505 -6RB by l-IaI1byw;ll SD505-6RB 6" Relay Base - ; • ase • —7,, ; ' , ∎, •y Engineering Specifications Relay base shall be Silent Knight module SD505 -6RB. The base shall be compatible with Silent Knight smoke detector modules SD505 -APS, SD505 -AIS, and SD505 -AHS. Each module shall be programmed with a separate SLC device address. The relay base shall provide one form C contact rated 8 amps for 240 VAC or 120 VAC and 30 VDC. s .S. 0 .... G. ) . . . ; . ' . 4 ' is -. 4 4 '• : .': . 1;1 • �ti_3rr, ,• Lj l Il j qd - I4 � i `� mit Class A (Style 6) Wiring Model SD505 -6RB With Detector and 6" Base (Detector sold separately) 4 - ... r 'q Ca !Ld• i1 A rot • . ,, c. . _ .k.,. ,._„... .„:.. ...--.!:, 1 --. 1-,I,....,.; (:). . •.4.: o d di ;:a_ i Class B (Style 4) Wiring Assembly SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA ti KNIGHT keep our product information up -to -date and accurate. We cannot cover all FORM# 350312 Rev C 04/07 specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight ©2007 Honeywell International Inc. by HI;e1L1Vwc.1 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Phone: (800) 328-0103, Fax: (763) 493 -6475. ,;,w, l q SD500 -PS and SD500 -PSDA 7' Addressable Pull- Station j � ;' 4s ) 1 ` '" ` . . ... " r com bine fast response IntelliKnight's addressable pull stations . , - ,. .,./ •� p onse wi th pin -point ; • � location ID • The SD500 -PS and SD500 -PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500 -PS /PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500 -PS /PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500 -PS & • Extremely easy to operate SD500 -PSDA • Corrosion - resistant gold- plated Addressable Pull • contacts. D U L L � • • Reflective label makes it easier Station to locate in low light The SD500 -PS is a single action Operation ' addressable fire pull station, and The SD500 -PS /PSDA single action 4"- .:. ' 'c ` ' the SD500 - -PSDA is a dual action pull stations are operated by a pull �� y " K ' addressable fire pull station. The on the front pull cover of the • SD500 -PS /PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable FIRE on back of the pull station allows module, is released as the pull interconnection of the pull station to station opens to initiate the alarm. the SLC of an IntelliKnight control Once operated, the cover hangs } panel. The SD500 -PS /PSDA is down and can be seen up to 100 c ALARM designed for indoor use in non- feet away. The pull station is reset e • xplosive environments. The by returning the front cover to the _ normally open initiating point normal upright position and contacts are gold - plated to avoid relocking the station with a reset risk of corrosion. The SD500- key. The reset keys are the same 'SILENT NIG T PS /PSDA has been tested by UL KNIGHT keys used on Silent Knight , - ----� for compliance to the requirements enclosures. of the Americans with Disabilities The SD500 -PS /PSDA includes a ACT (ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32 °F to 120 °F • UL Listed communicating with the loop. The (0 °c to 49°C) • CSFM listed status LED lights continuously Mounting: Single gang • ADA compliant during an alarm. A dip switch on box - the addressable module is used to Optional Red Surface Mount Box PS • Key reset (Same key as Silent set the unique address. Knight enclosures) • Surface mount back box Specifications available Operating Voltage: 24VDC SILENT • Terminals - accept up to 14 Alarm Current: Cu .55mA KNIGHT gauge wire p p Alarm Current: .55mA , - • • -- • SD500 -PS and SD500 -PSDA ,w „: -7°7'77 Addressable Pull- Station Engineering Specifications Manual pull station shall be addressable Module SD500- PS /SD500 -PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. '.\ rAcP ` \ \ ••'t ` ----• ! \ tM1 , - i-.-,k..,.: . g, ,,---- s \ l I, Inititi .. \�v � \ �t it d. • \'t � • .r \ , ' bi S. S. I �: ��1 -j - � +C.f11 : : ,r 'wCO ,�,I C - • • ■ • • 144 1■, ` Wiring 3 2.L2" -`_ t______ �� _ f I I • • Mounting to Single Mounting to Optional I Gang Electrical Box Surface Mount Box 1 r } SD500 -PSDA y Ji 1 _a 1 • I fir--4 _.. - _ 1 1 i Installing SD500 -LK Eluclricol mull be at leas, 1.W' Peep Dimensions SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 - 446 - 6444 or in Minnesota 763 - 493 -6435 FORM# 350342, Rev. 09/03 FAX: 763-493-6475 World Wide Web: http: / /www.silentknight.com Copyright © 2003 Silent Knight •, — . .— � ; k Addressable ...t S jy. f - tt�.. �-f s• Photoelectric Type . , tail, . . .: '..,,, ' ,-- +- , or g„.,,, . 11) Smoke Detector .. A ' , 1 r Detect smoldering fires quickly and get 4 ; ; s: help fast with IntelliKnight® photoelectric ��Y ,.' smoke detectors. •r IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 - APS The light received is converted into Analog / Addressable an electronic signal. Under normal . Photoelectric Type conditions, the status LED blinks k Smoke Detector approximately every 15 seconds, / The SD505 -APS is particularly indicating that the head is \ . a . suited to detecting dense smoke communicating with the loop. The typical of fires involving materials LED lights continuously during the such as soft furnishings, plastic, alarm period. foam or other similar materials Features • which tend to smolder and produce • Low profile, 2 inches, including SD505 -APS Smoke Detector large visible particles. base Specifications The detector features automatic • Simple and reliable addressing Operating Voltage: 17 -41 VDC compensation for contamination without mechanical switches Current Consumption: and a simple detector calibration • Automatic compensation for test procedure that can be run from sensor contamination Standby: .55 mA the panel or remotely (using the • guilt in fire test feature Alarm: .55 mA WindowsTM based downloading Simple detector calibration Ambient Temperature: 32 °F to 120 °F • software). ( through the control panel (0 °C to 49 °C) Operation or remotely through a Mounting: 4" Square, 4" The SD505 -APS units made up of WindowsTM based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a • Vandal- resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light • Field cleanable Air Velocity: 0 - 300 FPM from the pulsing light source. In the • UL listed, meets NFPA 72 Ch 7 event or fire, smoke enters the requirements Compatible Bases: SD505 -6AB detector and light is reflected from (Sold Separately) (6" Base) • the smoke particles to the receiving CSFM approved SD505-4AB element. • MEA approved (4" Base) • FM Approved SILENT NI KNIGHT by Honeywell Model SD505 -APS Addressable Photoelectric Type , - f'{% i Smoke Detector , r � - � i g,:4 '',It f Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505 -APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505 -AIS Ionization Smoke Detector, or SD505- . AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. t � Diameter = 5.15/16" of Diameter = 3- 15/16" N . If ►I %; 0 / . i ‘,, E .. c! 1 \,:-, \ % --. I . (' At9., I / , (:::±.:). \-. '''''' . ., I C ' o • ( �1 0 Height = 2 inches, — j — –r {( L. L including base / . �..- SlaN / • a " L . 1 Model SD505 -6AB Detector Base Model SD505 -APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA 10 KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev C,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight . Phone: (800) 328-0103, Fax: (763) 493 -6475. - , - • • -- Addressable Heat Detector 2 _ :, ,mss T- -t. '41 - •I:' .-- :" . x'3 c 5 i. IntelliKnight® addressable heat detectors gr . �..' *:, .11' .�. - combine accurate heat detection with pin -point ,r,►ri'� ' location ID. `1 yf : f An essential combination for any installation. IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other IntelliKnight detector models, the SD505 -AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 -AHS If the temperature exceeds the trip Addressable Heat point (programmed at the panel) an alarm occurs. The status LED - = �� Detector lights continuously during the alarm • < (%') The SD505 -AHS is a heat detector period. • ' , - suited to virtually any commercial Under normal conditions, the status I setting. The SD505 -AHS is an LED blinks approximately every 15 absolute temperature device. This seconds, indicating that the head is means that it responds in alarm if communicating with the loop. the temperature goes above the trip point (programmed at the Features panel). • Low profile, 2 inches, including SD505 - AHS Heat Detector The SD505 -AHS provides accurate base Specifications temperature measurement data to • Absolute temperature device Operating Voltage: 17 to 41 VDC the fire alarm control panel. This • Simple and reliable addressing Current Consumption: heat detector is particularly suited to environments where smoke • Use digital communication Standby: .55 mA detectors cannot be used because protocol Alarm: .55 mA of the presence of steam or • The SD505 - AHS is UL Listed Detection Temperature p Range: 135 °F to 150 °F cooking fumes, such as in a and meets the requirements (57 °C TO 65 °C) kitchen. outlined in NFPA 72 Inspection Ambient Temperature: 32 °F to 120 9 F Testing and Maintenance, pc to 49 Operation Chapter 7. The SD505-AHS unit is made up of Mounting: 4° SQR, 4° OCT • CFSM listed Single gang mud an externally mounted thermistor ring with a specially designed cover that • MEA listed protects the thermistor while • FM approved Rated Spacing: 70' between sensors allowing maximum air flow. The ceilings. on smooth thermistor reads the temperature from the air it takes in. It then SILENT Compatible Bases: SD505 - 6AB KNIGHT (Sold Separately) (6" Base) transmits a signal representing the ` SD505 - 4AB temperature to the IntelliKnight - (4" Base) panel. by Honeywell Model SD505 -AHS : ,,Y Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505 -AHS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505 -APS Photoelectric Smoke Detector, or SD505 -AIS Ionization Smoke Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF /transient suppression techniques shall be employed to minimize false alarm potential. N Diameter = 5 15/16" H Diameter = 3- 15/16" II H L. • ` ; o l 1 • Xj I r Height = 2 inches, ;fJ-L # -; • i including base - uii.�i Model SD505 -6AB Detector Base Model SD505 -AHS Detector Head (Front View) (Front View) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA It KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350229 Rev B,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. , - • • - • SD500 -AIM & SD500 -MIM ' 'p-L,' Addressable Input Modules f 4 1 e...:, ..,• : ,.. _ , "T.' IntelliKnight's addressable contact monitor ..: modules combine fast response with pinpoint location ID. A combination that saves lives and ' c ',' 93 4��•'• ; �' property. } ( aa The SD500 -AIM and SD500 -MIM are addressable input modules for use • a 'III k` •'''''= with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500 -AIM and SD500 -MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500 -AIM addressable input module mounts to a 4 "- square box. The SD500 -MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500 -AIM and SD500 -MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation —a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 763 - 493 -6435. Description • DIP switch programmable for fast The SD500 -AIM and SD500 -MIM are installation addressable input modules for use with • Up to 2500 ft wiring distance from the Intelliknight fire alarm control either input module to contact panels (FACPs). The SD500 -AIM • Use up to 14 gauge wire -;.• _ addressable input module mounts to a . UL listed - 4 "- square box. The SD500 -MIM mini , input module fits inside a single gang Electrical Specifications 0°: " box. Both input modules are designed Standby Current: 0.55 mA to be used with pull stations, water flow Alarm Current: 23 mA max for one • switches, and other applications device; 46 mA max for two devices; SD500 - AIM requiring dry contact alarm initiation 0.55 mA for each additional device devices. These modules are supervised, single Line Resistance: 500 max • input contact monitors. Using an EOL Mechanical Specifications ' resistor, they monitor for alarm contact SD500 -AIM Physical Description closures and for open circuit wiring Dimensions: ��- fault conditions. If a fault occurs in the 4.9" W x 4.9" H x 1" D wiring, the module alerts the FACP. (12.4 W x 12.4 H x 2.5 D cm) Each addressable input module is Weight: 3.6 oz (120.1 g) SD500 41IM programmed with a unique signal line Color: Ivory cover plate circuit (SLC) loop address. SD500 -MIM Physical Description Approvals Features Dimensions: NFPA 71 & NFPA 72 • Single contact monitor 1.5" W x 2.5" H x 0.7" D UL 864 • SD500 -AIM supports Class A (Style (3.8 W x 6.4 H x 1.8 D cm) D) or Class B (Style B) contact y Wei 1.6 oz (45.4 g) CSFM 7300-0559: 132 MEA 429 -92 -E Vol. IX monitor wiring pp FM A r Environmental oved for use with the 5820XL • SD500 -MIM support for Class•B Operating Temperature: (Style B) contact monitor wiring 32 °F - 120 °F (0 °C - 49 °C) • Attractive ivory cover plate with the SD500 -AIM Humidity: SILENT • Small and lightweight size allows for 10% - 93% non condensing EFS KNIGHT flexible mounting options with the S D500 -M I M by Honeywell - • •-- SD500 -AIM & SD500 -MIM • Addressable Input Modules • Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500 -AIM or SD500 -MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500 -MIM shall fit inside a single gang electrical box. The SD500 -AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4 "- square or double gang electrical box. The SD500 -AIM addressable input module must provide a monitor LED that is visible from outside the cover plate IC• ,I4 cc lc n no cur(.l ;I `N'/ j . . • L . � t7.— S _"'.I... ' ' ^'— ' b mna cl , Js C Tl t. 3. Compatible FACPs Ordering Information 5820XL SD500 -AIM Input Module 5808 Addressable input module with ivory cover plate. 5700 SD500 - MIM Input Module - Addressable mini input module. SI LENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA Kl\t1G j keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev D, subject to change without notice. For more information, contact Silent Knight by Honeytive�l 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. ©2008 Honeywell International Inc Phone: (800) 328 -0103 or 763 - 493 -6400 Fax: (763) 493 -6475. www.silentknight.com SpectrAlert Advance Dimensions lc-4.7' 2.5' 6.8' firElmm Dia. 1�� ■1 11 ��� _ Wall -mount horn strobes Ceding -mount horn strobes 7.1 2.25 r- 5.05• 2.23+1 Dia. 1 C o,Q.o , F 5.98• I o O poop / / Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Mod el y;Descrlption; :,ht ; ,;.i, . r, . ( Modell `:;Description r Wall Horn Strobes Ceiling Strobes P2R" 2 -Wire Horn Strobe, Standard cdt, Red SCR Strobe, Standard cd, Red P2RH• 2 -Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red P2W 2 -Wire Horn Strobe, Standard cd, White SCW' Strobe, Standard cd, White P2WH' 2 -Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White P4R• 4 -Wire Horn Strobe, Standard cd, Red Horns P4RH 4 -Wire Horn Strobe, High cd, Red HR Horn, Red P4W 4 -Wire Horn Strobe, Standard cd, White HW Horn, White Wall Strobes Accessories SR•' Strobe, Standard cd, Red BBS -2 Back Box Skirt, Wall, Red SRH•t Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White SW' Strobe, Standard cd, White BBSC -2 Back Box Skirt, Ceiling, Red SWH' ' Strobe, High cd, White BBSCW -2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes TR -HS Trim Ring, Wall, Red PC2R•. 2 -Wire Horn Strobe, Standard cd, Red TRW -HS Trim Ring, Wall White PC2RH 2 -Wire Horn Strobe, High cd, Red TRC -HS Trim Ring, Ceiling, Red PC2• 2 -Wire Horn Strobe, Standard cd, White TRCW -HS Trim Ring, Ceiling, White PC2WH' 2 -Wire Horn Strobe, High cd, White PC4R 4 -Wire Horn Strobe, Standard cd, Red PC4RH 4 -Wire Horn Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White Notes: • Add -P' to model number for plain housing (no 'FIRE' marking on cover), e.g., P2R -P t Add ' -SP'to model number for 'FUEGO' marking on cover, e.g., P2R -SP #'Standard cd'refers to strobes that include 15, 15/75.30. 75, 95. HO, and 115 candela senings.'High cd' refers to strobes that include 135, 150, 177, and 185 candela settings r Y STEN 3825 Ohio Avenue • St. Charles, IL 60174 R��t 02009 System Sensot. SENSOR' eto LIwpewithoul v e Visa systvn 4/0 ru Phone: 800- SENSOR2 • Fax: 630- 377 -6495 (went rn plodn m umssuoFn godula at mau ndWUSg • latest I/ vettim of sheet A05 -0395-007 • a /U9 • X1111 Ell SILENT SK -Photo TIGHT and by Honeywell SK- Photo -T Intelligent Photoelectric Smoke Sensors The SK -Photo is a photoelectric smoke detector and the SK- Photo -T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800 - 328 -0103. Description • Plug -in mounting provides ease of SK -Photo and SK- Photo -T are p lu gin installation type smoke sensors that combine a • Tamper -proof feature available on photoelectric sensing chamber with mounting bases s addressable analog communications. • Listed for use in duct applications ;` .. , Point ID capability allows each detector's address to be set with rotary • Rotary address switches for fast t Al tivii ! I I I, • address switches, providing exact installation lc i detector locations for selective • UL Listed . maintenance when chamber contamination reaches unacceptable FM Approved _ - • levels. • SK Photo and SK-Photo-T have a unique optical sensing chamber that is Specifications engineered to sense smoke produced Physical by a wide range of combustion Height: 2.0" (5.0 cm) sources. In the SK- Photo -T, dual Diameter: 4.1" (10.4 cm) SK -Photo (Base included) electronic thermistors add 135 °F (57 °C) Shipping Weight: 5.2 oz. (147 g) thermal technology to maximize detection. Electrical Operating Voltage: 15 -32 VDC Compatibility Standby Current: The SK -Photo and SK- Photo -T are Features 300 pA @ 24 VDC Maximum compatible with the following • Sleek, low- profile design Alarm Current: 6.5 mA @ 24 VDC max IntelliKnight FACPs: • Base included (with LED on) 5700 • Reliable analog communications for Environmental 5808 trouble -free operation Operating Temperature 5820XL • Age resistant polymer housing SK- Photo: 32° — 120 °F (0 °C — 49 °C) SK Photo and SK Photo T are SK-Photo-T: 32° — 100 °F (0 °C — 38 °C) compatible with the following detector • Dual electronic thermistor design on bases: the SK Photo T Humidity: 10% — 93% non - condensing B210LP (included) 6" base • Superior EMI resistance for reliability Other Ratings B501 2 wire base SK- Photo -T Thermal: Fixed B224RB Relay base • Simple field cleaning for code temperature set point 135 °F (57 °C) B224BI Isolator base compliance Velocity: 0 —4000 fpm (0 — 20 m /sec) B200SR Sounder base - • Variety of mounting options to meet SK -Photo Insect Screen Hole Size: any application 0.016" (0.41 mm) nominal • Dual LED indicators for 360° visibility • Detector transmits signal to indicate maintenance is required • Optional remote LED annunciator (System Sensor® PN RA100Z) -. - . •-• Model SK -Photo and SK- Photo -T Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK -Photo or SK- Photo -T with thermal. The combination detector head, and twist -lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK -Photo or SK- Photo -T. Base shall be the appropriate twist -lock base part number B210LP (included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK -Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. • sic IN OUT . " comp tt F0.GP ■ + f - • RA.1002 IO iliundl: • • e---.7—:- ' : (/;:-.. te: .�. (4 w,. I i - _,_, }' • • Class / 411n M.1111 Winn; I - 1 W -*+lig : :k-Se�na De; - r Ntanung tJatsea if SIT., T This document is not intended to be used for installation purposes. We try to MADE IN AMERICA c b, K I I i HT k e ep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350118 Rev B, subject to change without notice. For more information, contact Silent Knight © 2010 Honeywell International Inc. by Honeyweu 12 Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, Fax: (203) 484 -7118. www.silentknight.com SK -Relay .5 1 r14. � •7 ' Air Intelligent Relay Module • 111A " • The SK Relay Module is intended for use in intelligent, two -wire systems 4 . `^ where the individual address of each module is selected using the built in rotary switches. i. r. ,'- a '••, ��iaj For more information about the Intelliknight system, or to locate you nearest source, please call 800- 328 -0103 or in Connecticut, call (203) 484 -7161. Description The SK -Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACP x. .,04! ; * a ti i , C . ea . • The SK -Relay allows a Silent Knight FACP to switch discrete i 4 contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK -Relay contacts can be used for virtually any normally % `. open or normally closed application. Each SK -Relay is programmed with a unique signaling line circuit (SLC) loop • address. When an event occurs that controls the SK- Relay, the SK - Relay relay is triggered by the FACP. Installation Features The SK -Relay mounts directly into a 4" square electrical box. The box must have a minimum • Two sets of Form C contacts depth of 2 -1/8 ". A surface mount electrical box • Rotary address switches for fast installation (System Sensor® PN SMB500) is available • Contacts are rated for a variety of amps (see Specifications) from Silent Knight • Panel controlled status LED that flashes green in normal state and is solid red in alarm Compatibility The SK -Relay is compatible with the following • Relay programming is completely flexible —can be mapped to IntelliKnight FACP's: zone conditions 5700 5808 • Polling LED visible through the cover plate 5820XL • Attractive ivory cover plate • SEMS screws for easy wiring t SILENT • UL Listed j KNIGHT by Honeywell • Model SK -Relay it i3 4 v To Next Device + ; I f Any Wiring to Terminals 3 — 9 is Not Power Limited, the CB500 Barrier is Required. The CB500 Includes a Non -Power Limited Label, I1 n Which Must Be Placed Over the Power Limited O O O Terminal Information on the Name Plate Label, Relay Common 2 x e t. oMI Normally Closed 2 FJ e �� �{• 1 Ea Normally Open 2 7 2 Relay Common 1 3.0: 0 , • 3 — From Compatible FRCP tr .; Normally Closed 1 ®e .y 4 a + or Previous Device Module Does Not Supervise (1 O n ° O Normally Open 1 Controlled Circuits (� U U Wiring the SK -Relay Module • Specifications End -of -Line Resistance: not used Physical Standby Current: 300 pA max @ 24 VDC (one Height: 4.65" communication every 5 sec with LED enabled) Width: 4.25" LED Current: 5.5 mA (with LED latched on) Depth: 1.1" SLC Loop Resistance: 400 max. Shipping Weight: 6.3 oz (196 g) Relay Contact Ratings Electrical 3.0A @ 30 VDC resistive Operating Voltage: 15 — 32 VDC 0.9A @ 110 VDC resistive Current Draw: 6.5 mA max (LED on) 0.9A @ 125 VAC resistive Operating Current: 0.5A @ 125 VAC inductive (PF = .35) 230 pA (LED flashing) direct poll 0.7A @ 75 VAC inductive (PF = .35) 255 pA (LED flashing) group poll SILENT This document is not intended to be used for installation purposes. We try to keep our product information up - to - date and accurate. We cannot cover all MADE IN AMERICA KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight FORM# 350127 Rev A by Honeywell 12 Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, © 2009 Honeywell International Inc. Fax: (203) 484 -7118. www.silentknight.com SYSTEM SENSOR' • Selectable Output Chimes and Chime /Strobes r SpectrAlert °Advance selectable - output chimes and ' chime /strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTRAIert C E SpectrAlert Advance selectable- output chimes and chime/ Features strobes are private mode notification appliances used to alert trained • personnel to investigate possible emergency situations and to take Plug in design appropriate action. Security guard and nurse workstations are ideal • Shorting spring on mounting plate for pre - installation continuity locations for chime products. check • SpectrAlert Advance chimes and chime /strobes are rich with Captive mounting screw features guaranteed to cut installation times and maximize profits. • Torx screw for tamper resistance The SpectrAlert Advance Series of notification appliances is designed • to simplify your installations, with features such as plug -in designs, Field selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115 instant feedback messages to ensure correct installation of individual • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 devices, and seven field - selectable candela settings for chime/ candela strobes. • Minimal intrusion into the back box More specifically, when installing SpectrAlert Advance products, first • Rotary switch for tone selection attach a universal mounting plate to a four -inch square, four -inch • octagon, single -gang, or double -gang junction box. Then, connect Two volume settings the notification appliance circuit wiring to the SEMS terminals on the • Electrically compatible with existing SpectrAlert products mounting plate. • Listed for ceiling or wall mounting Finally, attach the chime or chime /strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device is rotated into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captive mounting screw. SpectrAlert Advance products allow you to choose: Agency Listings • 12 or 24 volts • At 24 volts, 15, 15/75, 30, 75, 95, 110, or 115 candela by way of rear- SIGNALING ��• mounted slide switch and front view window ® ® MEA (0) • Select chime tones and volume using a simple rotary switch approved LISTED APPROVED 7125.1653:1813Itlmnr /suOhes) 54011 3023572 MEA452.05-E 7125.1653:189 (chimes) SpectrAlert Advance Specifications h Archite , ' i. ons , ,` - General ct /Engineer Specificati • } "° � � i' i` r� . SpectrAlert Advance chimes and chime /strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box, single -gang 2 x 4 x 11/4-inch back box, or double -gang back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Chime/ strobes shall have held-selectable candela settings of 15, 15/75, 30, 75, 95, 110 and 115. Chime /Strobe Combination The chime /strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and UL 464. The chime /strobe shall comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The chime shall have two audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern.These options are set by a multiple position switch. Synchronization Module The module shall be a System Sensor Sync-Circuit listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and chimes.at temporal three. Also, while operating the strobes, the module shall silence the chimes on chime /strobe models over a single pair of wires. The module shall mount to a 4° /1b x 4%b x 21/4-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical /Electrical Specifications , Standard Operating Temperature 32 °F to 120 °F (0 °C to 49 °C) Humidity Range 10 to 93% non - condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5V (12V nominal) or 16 to 33V (24V nominal) Input terminal wire gauge 12 to 18 AWG Chime /strobe dimensions (including lens) 5.6 in L x 4.7 in W x 2.5 in D (142 mm L x 119 mm W x 64 mm D) Chime dimensions 5.6 inLx4. 7inWx1 .3inD(142mmLx119mmWx33mmD) BBS -2 (red back box skirt) 5.9 in Lx 5.0 in W x 2.2 in D (151 mm L x 128 mm W x 56 mm D) BBSW -2 (white back box skirt) 5.9 in L x 5.0 in W x 2.2 in D (151 mm L x 128 mm W x 56 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non - filtered, time varying power source that is used on some power supply and panel outputs. 2. CHS products will operate at 12 V nominal only for 15 and 15/75 cd. ADS 0396 .003 UL Current Draw Data UL Max. Chime Current Draw (mA RMS) ' 8 -17.5 Volts 16 -33 Volts Sound Pattern dB DC FWR DC FWR 1 Second Chime High 34 50 58 51 1 Second Chime Low 30 51 51 54 /4 Second Chime High 34 51 50 50 Vs Second Chime Low 31 51 50 52 Temporal Chime High 30 50 48 54 Temporal Chime Low 30 47 50 51 5 Second Whoop High 32 52 34 54 5 Second Whoop Low 30 40 34 52 Coded High 48 49 50 50 • This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. UL Max. Chime /Strobe Current Draw (mA RM5) . 8 -17.5 Volts 16 -33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 1 Second Chime High 131 142 65 76 94 160 185 207 213 1 Second Chime Low 131 142 64 75 92 157 183 203 212 1/4 Second Chime High 129 142 66 75 95 159 184 205 212 1/4 Second Chime Low 129 142 64 74 91 155 181 204 211 Temporal Chime High 125 142 64 74 91 156 181 205 211 Temporal Chime Low 129 141 65 75 92 155 180 200 209 5 Second Whoop High 133 145 70 81 99 165 189 210 217 5 Second Whoop Low 130 143 66 77 95 160 186 206 214 One Time Chime • 127 141 64 76 93 156 182 203 210 8 -17.5 Volts 16 -33 Volts FWR Input 15 15/75 15 15/75 30 75 95 110 115 1 Second Chime High 128 150 72 82 98 158 183 202 210 1 Second Chime Low 127 150 71 81 97 157 182 202 210 1/4 Second Chime High 129 149 72 82 99 160 183 203 211 1/4 Second Chime Low 128 149 71 81 97 154 179 196 205 Temporal Chime High 128 148 71 81 97 157 179 199 206 Temporal Chime Low 125 147 71 81 97 156 180 200 206 5 Second Whoop High 136 152 84 93 110 170 193 212 220 5 Second Whoop Low 132 150 77 86 102 161 184 203 214 One Time Chime • 127 147 72 82 97 157 181 200 210 •Chime /Strobes cannot be powered with a coded supply. Tone Selection Chime tone selection is accomplished by using the rotary switch on the back of the product. The current draw and sound measurements for various chime tone settings are listed below. Chime Patterns Chime and Chime /Strobe Output (dBA) • Setting Repetition Rate dB Level Switch 8 -17.5 Volts 16 -33 Volts 1 1 Second Chime High Position Sound Pattern dB DC FWR DC FWR 2 1 Second Chime Low 1 1 Second Chime High 58 59 61 61 3 1 / Second Chime High 2 1 Second Chime Low 53 54 55 55 4 V. Second Chime Low 3 /4 Second Chime High 63 64 66 66 5 Temporal Chime High 4 1 4 Second Chime Low 58 59 60 60 6 Temporal Chime Low 5 Temporal Chime High 62 64 68 69 7 5 Second Whoop High 6 Temporal Chime Low 55 57 60 60 • 8 5 Second Whoop Low 7 5 Second Whoop High 68 71 /5 77 9 One Test Chime /coded High 8 5 Second Whoop Low 62 64 67 68 9 One Test Chime /coded High 57 55 51 57 A0S 0396.003 SpectrAlert Advance Dimensions 4.7' 1.3" 4.7" 2.5--0 15.0" -► 2.2" 5.9 I L J 56 J iLI ti o -00 Chime Chime /Strobe BBS- 2/BBSW -2 SpectrAlert Advance Ordering Information Model, Description .,. CHR Chime, Red CHW Chime, White CHSR Chime /Strobe, Red CHSW Chime /Strobe, White Accessories BBS -2 Back Box Skirt, Wall, Red BBSW -2 Back Box Skirt, Wall, White C . • r • CHSR CHSW CHR CHW Red Chime Strobe White Chime Strobe Red Chime White Chime *� SYSTEM 02007 System Sensor 1 SENSOR' Phone: Ohio Avenue • St. Charles, IL 60174 Product speolrauons subject to change wthuut home WA systemsensw C0111 lot Phone: 800- SENSOR2 • Fax: 630-377-6495 current product information inducing the latest srnionol this data sheet . A09 -0396 - 003.12/07.11890 *:---- SYSTEM . �$ SENSOR' ::� Selectable-Output - I 1- H r orns, Strobes, and � ' ._ R � ' = j Horn Strobes it , e . 1 gi , ..: . Ms SpectrAlert Advance selectable-output horns, strobes, -. and horn strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTfpA ert N C Features The SpectrAlert Advance series offers the most versatile and • Plug -in design with minimal intrusion into the back box easy -to -use line of horns, strobes, and horn strobes in the industry. Tamper resistant construction With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 meet virtually any application requirement. candela • Field- selectable candela settings on wall and ceiling units: 15,15/75, Like the entire SpectrAlert Advance product line, horns, strobes, 30, 75, 95, 110, 115, 135, 150, 177, and 185 and horn strobes include a variety of features that increase their - • Horn rated at 88+ dBA at 16 volts application versatility while simplifying installation. All devices Rotary switch for horn tone and three volume selections feature plug -in designs with minimal intrusion into the back • box, which make installations fast and foolproof while virtually • Universal mounting plate for wall and ceiling units eliminating costly and time - consuming ground faults. Furthermore, • Mounting plate shorting spring checks wiring continuity before a universal mounting plate with an onboard shorting spring tests device installation wiring continuity before the device is installed, protecting devices • Electrically compatible with existing SpectrAlert products from damage. • Compatible with MDL sync module In addition, field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALING g USTED APPROVED MEA approved 2 5 - 1518E bndoos 111obes) 7 12 R5- I6 3 183 mom strobes, 51011 (,limes, hem strobes. ham) 3023572 MEA952-05 -E ch,me svobes) 55512 (umbes) 7135 -1653 169 Owns. chimed SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 1 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync - Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12- volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24- volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system. The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4'r /r6 x 4"/16 x 21/4-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32 °F to 120°F (0 °C to 49 °C) Humidity Range 10 to 93% non - condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWRI Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8 diameter x 2.5 (173 mm diameter x 64 mm high) Wall -Mount Dimensions (including lens) 5.6 - L x 4.7 x 2.5 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6 x 4.7 - W x 1.3 mm L x 119 mm W x 33 mm D) Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW -2) 5.9 - L x 5.0 - W x 2.2 - D (151 mm L x 128 mm W x 56 mm D) Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7.1 diameter x 2.2' high (180 mm diameter x 57 mm high) Wall -Mount Trim Ring Dimensions (sold as a S pack) (TR -HS, TRW -HS) 57 - L x 4.8 - W x 0.35 - D (145 mm L x 122 mm W x 9 mm D) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC -HS, TRCW -H5) 6.9 diameter x 0.35 - high (175 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05- 0395-007 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8 -17.5 Volts 16 -33 Volts 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non - temporal High 57 56 69 75 95 NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15 -115 cd) - r 8 -17.5 Volts 16 -33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - Temporal High 141 152 91 100 116 176 201 221 229 Non - Temporal Medium 133 145 75 85 102 163 187 207 216 Non - Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non - Temporal High 142 161 103 112 126 181 203 221 229 Non - Temporal Medium 134 155 85 95 110 166 189 208 216 Non- Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, High Candela Range (135 -185 cd) 16 -33 Volts 16 -33 Volts • DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - Temporal High 255 270 303 309 Non - Temporal High 233 248 275 281 Non - Temporal Medium 242 259 293 299 Non - Temporal Medium 219 232 262 267 Non - Temporal Low 238 254 291 295 Non - Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8 -17.5 16 -33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non - Temporal High 82 82 88 88 93 92 100 100 • 5 Non - Temporal Medium 78 78 85 85 90 90 98 98 6 Non - Temporal Low 75 75 81 81 88 84 96 92 7 Coded High 82 82 88 88 93 92 101 101 8' Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2 -wire horn strobe. A0S -0395-007 I,,, <<iiTT 1� 1 , 1 '.47: � �i 11 1 • - Global Project Values: • y * ¢' iN. " 41,8 3, 7 Project Name:IPACIFIC GARDENS I . - Standby Hours:I 24 I - 4 41 b c ' ! y q a I , ' 1 ,. ; ; Project ID:IMain Cont Panel I Alarm Mins:I 5 I • �, . , a e� Ar; i a Prepared By:IJUSTIN SMITH I Derating Factor) 1.2 I • 4 , ,t t . i • I w'i t Date:I4 /25/2011 I Voltage Drop Warning 'Y ` �' Version 08.19. : j , �s t Threshold % :I 10 I Panel ID: I5820XL I Model: 5820XL Add. Fire Alarm Control Panel Max NAC Current: 3.0 Amps • Location: ITIGARD OR I Volts: 24 VDC Max Panel Current: 6.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual - Volts @ Ckt.# Circuit Name Qty Standby Alarm & Type 1000 Ft. One -Way Ohms EOL %Drop 5820XL 5820XL CTRL Panel 1 0.215 0.385 . SK Photo, Photo -T 71 0.019 0.019 • SK Ion 0.000 0.000 • • SK Heat, Heat -HT 0.000 0.000 SK Heat ROR 7 0.002 0.002 . SK Beam, Beam -T 0.000 0.000 . SK Duct 0.000 0.000 • SK Acclimate 0.000 0.000 SK Control 0.000 0.000 • SK Control -6 0.000 0.000 • SK Monitor, Minimon 3 0.001 0.011 SK Monitor -2 0.000 0.000 • • SK Monitor -10 0.000 0.000 SK Pull -SA, Pull -DA 4 0.002 0.002 SK Relay 0.000 0.000 SK Relay -6 0.000 0.000 SK Zone 0.000 0.000 SK Zone -6 0.000 0.000 . • SK Isolator Module 0.000 0.000 . • SSB224BI Isolator Base 0.000 0.000 SSB501 BHT Sounder Base 0.000 0.000 ' SSB224RB Relay Base 43 0.022 0.022 • • SSRTS151 Magnetic Remote Test 0.000 0.000 • •SSRTS151KEY Key Activated Test 0.000 0.000 . • • . SSRA100Z Remote LED 0.000 0.000 5815XL SLC Loop Expander 0.000 0.000 . 5860 LCD Remote Annunc 1 0.020 0.025 . 5824 Serial /Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 • 5865 -4 LED Annunciator (4G) 0.000 0.000 • 5865 -3 LED Annunciator (3G) 0.000 0.000 • 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 • PGM -I /O #1 Notification Appl Circuit 0.000 0.470 #18 Solid 6.39 200 2.56 19.20 5.89% PGM -I /O #2 Notification Appl Circuit 0.000 0.569 #16 Solid . 4.02 275 2.21 19.14 6.17% PGM -I /O #3 Notification Appl Circuit 0.000 0.808 #16 Solid 4.02 185 1.49 19.20 5.89% PGM -I /0 #4 Notification Appl Circuit 0.000 0.396 #18 Solid 6.39 200 2.56 19.39 4.96% PGM -I /O #5 Notification Appl Circuit 0.000 0.000 #18 Solid 6.39 300 3.83 20.40 0.00% PGM -I /O #6 Notification Appl Circuit 0.000 0.000 #18 Solid 6.39 300 . 3.83 • 20.40 _ 0.00% . Total Standby Current (Amps) 0.280 2.709 Total Alarm Current (Amps) Standby Time In Hours 24 , 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 6.729 0.226 Total•Alarm AH Required • Total Combined AH Required 6.96 Command Shortcuts • Multiply By The Deratinp-Factor 1.20 r . Minimum Battery AmpHours Required 8.35 Configure Circuits 1 Print Page • J l 2 A H B c, T1 e (c Y i°3 ac, IL - (' t" 1 I 13e f s7 l lti/ 1_, ,L Rif F NT { 4C K 1 •! ^� ! ilb'4 ±ki,°c� i i L,n ),ii •k t{!Silf r:nt ! , l s � of f'r k , ° ; ') 1 ! .,.lr f F , 4., ;1• .� .� e i a r r !, : 7 Al e 1 '!i e k �` 5 - ' ' j , ,' i i . 4 ' J . .. 4 ' 44 ' si , 1 - "Z i t ill Wrattyp . -, 4e..,-C, ; , ° , 1 , ,. , k! . 10. i ! „ �,r , � ;�� g .. . ., : 9 Project Information • Project Name: PACIFIC GARDENS Project ID: Main Control Panel Prepared By: JUSTIN SMITH Date: 4/25/2011 Ckt. Number: PGM -I /O #1 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Usel Notification Appl Circuit L. Qty Device • Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 System Sensor CHS Chime /Stobe (15cd) 0.000 0.070 0.000 0.140 1 System Sensor CHS Chime /Strobe (30cd) 0.000 0.099 0.000 0.099 1 System Sensor CHS Chime /Strobe (75cd) 0.000 0.165 0.000 0.165 1 System Sensor S /SC Strobe (15cd) 0.000 0.066 0.000 0.066 0.000 0.000 Totals 0.000 0.470 Ckt. Number: PGM -I /O #2 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit _ ■ Qty Device Current Draw Each Currant Draw Total Standby Alarm Standby Alarm 1 System Sensor CHS Chime /Strobe (75cd) 0.000 0.165 0.000 0.165 2 _ystem Sensor CHS Chime /Stobe (15cd) 0.000 _ 0.070 0.000 0.140 4 S ystem Sensor S /SC Strobe (15cd) 0.000 0.066 0.000 0.264 0 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.569 Ckt. Number: PGM -I /O #3 • Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: LNotifiwti Appl Circuit ■ Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor CHS Chime /Strobe (75cd) 0.000 0.165 0.000 0.165 4 System Sensor CHS Chime /Stobe (15cd) 0.000 0.070 0.000 0.280 1 System Sensor S /SC Strobe (15cd) 0.000 0.066 • 0.000 0.066 3 _System Sensor CHS Chime /Strobe (30cd) 0.000 0.099 0.000 0.297 0.000 • 0.000 Totals 0.000 I 0.808 „� S1I.LN 1 ���� �tiii� a �' -� l k { . , +`� � r � i A I�`t�. 7f�'� {� � 'dl��'� �ucl� �3. f ' ' j , ` „ � .3r� t� , . . sip � 1 t'i^ .SW � r r�r � ;e � v�t � � r � t[ �� q� ,'` }a< � y �,� f M �.j t r .j �,fta , t �� ;v� }, t 4 44,414:4-;.' t 4 , =w t,_t i iic 1 A.. •,. .t "' �0 r 40%.l ,{�' iv.1 +,rw� ' t); ■ t4` i'lie J; e1 '7Nj Project Information • Project Name: PACIFIC GARDENS Project ID: Main Control Panel Prepared By: JUSTIN SMITH Date: 4/25/20' 1 Ckt. Number: PGM -I /O #4 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: [Notification Appl Circuit __ 1 Qty Device Current Draw Each • Current Draw Total Standby Alarm Standby Alarm 1 System Sensor CHS Chime /Strobe (30cd) 0.000 0.099 0.000 0.099 1 System Sensor CHS Chime /Strobe (75cd) 0.000 0.165 0.000 0.165 0 System Sensor S /SC Strobe (15cd) 0.000 0.066 0.000 0.000 2 System Sensor S /SC Strobe (15cd) 0.000 0.066 0.000 0.132 0.000 0.000 Totals 0.000 0.396 Ckt. Number: PGM -I /O #5 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit __ V Qty Device Current Draw Each Current Draw Total Standby Alarm Standby . Alarm _ 0 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused _0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: PGM -I /O #6 Panel ID: 5820XL Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Circuit w Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 0 Unused 0.000 _ ..0.000 0.000 0.000 Unused _ 0.000 . 0.000 0.070 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 • 0.000 Totals 0.030 0.000 [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]