Specifications 9 7075 5--1(J ,/14 EC 5 - 0079 70 B r HIGHLY- EFFICIENT 4 -WAY MULTIPOISE 350MAV jj'yant J , FIXED - CAPACITY DIRECT -VENT Heating&coolingsYstems DELUXE CONDENSING GAS FURNACE Sizes 040 thru 140 • infiltration of cold air into the structure and reducing heat loss. 3-Pass Primary Heat Exchangers—This design accelerates heat transfer and extracts heat that conventional heat exchangers waste up the flue. The weld -free primary heat exchangers are 0 made of aluminized steel for corrosion resistance. mow Flow -Through Secondary Heat Exchangers—Each cell is lami- nated with our patented EverlasticTm polypropylene for greater resistance to corrosion. This breakthrough in heating technology helps extend the life of the furnace for years of trouble -free Plus 90 performance. The heat exchanger is positioned in the furnace to extract additional heat from the combustion products regard- less of furnace orientation. Warranty— Limited Lifetime Warranty on the heat exchangers for the lifetime of the original owner in single family residence; 20 -year limited warranty in other residential and commercial applications. Contact your dealer for details. Three -year limited warranty on microprocessor control, hot surface ignitor, and in- 0 O ducer motor. Monoport Inshot Burners— Produce precise air - to-gas mixture which gives a clean burn. The large monoport on the inshot or injection -type burners seldom, if ever, needs cleaning. Microprocessor Control Center —The printed - circuit board and all internal wiring are factory installed. Convenient terminals permit quick- connection of a thermostat, a humidifier, an air cleaner, 0 and air conditioning control circuits. The control has adjustable blower off delay switches. As an added feature, the control has a built -in status indicator and self -test fea- ture. The status indicator flashes to indicate a problem condition Utilizing the extensive resources available to Bryant, a new stan- and assists the servicer in diagnosis. The self -test feature allows dard of excellence has been achieved with the model 350MAV for a complete check of the major components in only seconds. Plus 90TM' 4 -Way Multipoise Furnace. Combustion Air and Ventilation —The 350MAV advanced design The model 350MAV was designed around requirements estab- allows Schedule 40PVC, PVC -DWV, SDR -21 PVC, SDR -26 lished by customer focus groups. The result is a unique 4 -way PVC (not approved in Canada), ABS -DWV, or ABS -F628 multipoise condensing furnace with features like no other prod- Schedule 40 pipe to bring outdoor air into the furnace for corn - uct in its class. The 350MAV builds on the many Bryant suc- bustion. The extracted heat lowers the temperature of the corn - cesses in the furnace industry and establishes a new standard bustion products to a point (typically below 115 °F) that any of the for all high- efficiency gas furnaces. approved types of pipe can also be used for venting combustion products outside the structure. The combustion -air and vent FEATURES pipes can terminate through a side wall or through the roof when 4-Way Multipoise Design — Allows a 350MAV model to be in- using 1 of our approved vent termination kits. stalled in an upflow, downflow, or horizontal orientation. Factory Fully - Insulated Casing —Foil -faced insulation in the heat ex- configured for upflow applications. Simple changes in the drain changer section cuts heat loss, and insulation in the blower sec - connections are all it takes to change to any of the 3 other pos- tion reduces noise levels. The casing also has the required sible positions. openings for left- or right -side connection of gas, electric, drain, The model 350MAV is available in 12 heat/airflow combinations, and vent connections. and when combined with the 4 -way design, allows for 48 differ- Cecations —The 350MAV units are A.G.A. and C.G.A. design ent applications. certified for use with natural and propane gases, as well as Media Filter Cabinet — Enhanced indoor air quality in your home GAMA efficiency rating certified. The furnace is factory- shipped is made easier with our media filter cabinet —a standard acres- for use with natural gas. An A.G.A. /C.G.A. listed gas conversion .,; sory on all Deluxe furnaces. When installed as a part of your sys- kit is required to convert furnace for use with propane gas. The tem, this cabinet allows for easy and convenient addition of a model 350MAV meets the California Air Quality Management Bryant high- efficiency air filter. District emission requirements. Except for the 140 size unit, all Sealed Combustion (Direct-Vent) System— Enclosed burner as- 350MAV models can be installed in a manufactured (mobile) sembly isolates operating noise without the expense of sound home when the optional kit is used. deadening devices. The sealed combustion (direct -vent) system Quality Registration —The 350MAV is engineered and manu- brings outdoor air directly into the combustion chamber, reducing factured under an ISO 9001 registered quality system. Form No. PDS 350M.40.10 '` 26 'BA" - i 28 W' 26 W - L 26 lie" - 24 W' AIRFLOW l 26'h" • 22 35e' 13 A 1a 2UTLE 24N. COMBUSTION- / +e" D / +e" e/ 19" ....-lie" CONN CONDENSATE DRAIN 'IT—OUTLET OUTLET I e y ( T ( RAP LOCATION ° 1 HOOR LEFT) CONDENSATE TRAA7101N 11 + 2 IN COMBUSTION- T 'h IN. DA O O O (DOWNFLOW 8 I I I r AIR CONN Ile' ONTAL RIG 1/44N. IN. DIA /� POWER CONN II--II HORIZHn GAS CONN \/ ��' 'h-IN. D OR ALTERNA A GAS CONN I GAS CONN 2 -IN. VENT CONN _., o A A 7h•IN. DIA 33'h" P W CONN Y I -IN. DIA THERMOSTAT eh' TYP �— 'h IN. DIA ENTRY 3013AB TYP THERMOSTAT ENTRY -.4-- 22 "Ae" 34-IN. DIA 30 W 39 'A" ACCESSORY 29 "M" 2 -IN. VENT CONN POWER ENTRY (Q 27eh " TYP CONDENSATE v -• -• -• 22'9m 7 . -. _..NI, v ..- .- .- .--- .- . - - -. - � DRAIN TRAP 27 LOCATION TYP • I (ALTERNATE 24th" I I I UPFLOW) 1 14'h' I SIDE INLET 17 9'ie" 18'/x" j SIDE INLET TYP j 1 I j 1 i 9 I 1 TYP 0 00 • 1• TYP 1 E NLET II CONDENSATE �_ 22'h "TYP — .I I I - -� � CONDENSATE 1' 23 "M"-6.1[0------ 1I IL. „ he" DRAIN LOCATION /'" DRAIN LOCATION SIDE INLET (UPFLOW) (UPFLOW) 24 311. "AG" 28 lie" TYP DIMPLE LOCATORS BOTTOM INLET N FOR HORIZONTAL HANGING NOTES: 1. Minimum return -air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturers recommendations for equivalent diameters. 2. Minimum return -air opening at furnace: a. For 800 CFM- 16 -in. round or 141/2 x 12 -in. rectangle. b. For 1200 CFM- 20-in. round or 141/2 x 19'/2 -in. rectangle. c. For 1600 CFM- 22 -in. round or 141/2 x 231/2-in. rectangle. d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM at 0.5" W.C. ESP. A02147 DIMENSIONS (In.) UNIT SIZE A D E SHIP. WEIGHT (Lb) 024040 17-1/2 15-7/8 16 174 036040 17 -1/2 15 -7/8 16 175 024060 17 -1/2 15 -7/8 16 180 036060 17 -1/2 15-7/8 16 182 048060 17-1/2 15 -7/8 16 183 036080 17 -1/2 15 -7/8 16 198 048080 17 -1/2 15-7/8 18 205 060080 21 19-3/8 19-1/2 214 048100 21 19 -3/8 19-1/2 229 060100 21 19-3/8 19-1/2 232 060120 24-1/2 22-7/8 23 261 060140 24-1/2 22 -7/8 23 261 Clearance to Combustibles v INSTALLATION nis forced air f u rece is equipped fa tae with natural gas at altitudes 0.10,000 f t (0 - amen), =e 4140 size Braces are Orly rimmed for altitudes 0.7,000 ft. (0 - Z135n). An accessory at, supplied by the nerufact ra, shall be used to carved to propane gas use a may be regdrm for sane natural gas applications. This furnace I for Wow installation In a diking ousbucted ar eta iris fame nay be Installed In a ma (mcbfe) ham than stated on rating plate ad using factory authorized 161. This Imam nay be Installed on wrrttatide flooring in *as a cheat d nirdnun deararce Iran asitsatiide metaled. This apliace regires a aped wring system Defer to the irestallatim Irsbudlas for parts be and rndtcd of Installation ills fumaoe is for use aith wire kle.40 PVC, PVC -O W, CPVC, a ABSUNV ppB, and mat not be tented in oarrrrcn with other gas-fired replaces. Cc stndkn though which ■.ert/ah isisiw rupee may be hshaled is natdrrum 24Inches (6W mm), m 3/4 Inches (19 mm) Itudoess enacting Wing matedas). CetiB famaise it air Nsa est ad* par Beaton met gaz rsturel at altitudes oarpLses ate 0.3,050n (01 Uns r ire o sm cawasial farce le Uncut par Passer Palm al Par crtarhes intalailaticne at —Pi ratwa. Cette foumaisa A air pulse CO par IrstaDatbn A Iirsddeur dais an Wirral wrebnit sun place. Celle bumalse A air area pea etre Irstal&e dare uhe malacn PAtabrldee (mats motile) si cresol per La plaque sgnaletc a el si rah raise ire beam spedfloa per le Want. Cete famhase pad Cba b151a06e Sur in pleader t orrtuatde dare in adorcenend sou is placard at observant is deggements nlrimne avec be maffiriam wntustlies. Ca apparel! ndmsaite at system° awe:intim spddal La rrhtthode dirstatallon at la Ilde as peas newswires figural dans les Irsh dare d irslallalaLCette latrn fee ddt Sr Olifse Rae la fuyatede use r arendahres 40 WC, WC-DWV, CPVC, at ABSOVW at elle ne peat pas ere 'matte ooridrtnerd eves dachas apparels A gaz Eraser de la mrstnctiah au trams de Iagafie fi est Pestle da faire mesa be tuyaau dedrabm (atrrisslanhearabm): 24 po (600 mm) nmdnwq 3 p° (19 ran) nirimm b murals fa taus). For u pftow err dowrdtow applications, brace mat be installed tewl,, or pitched within 12' of level. For a horizadai application, the furnace brat be pitted rrinanam 114' to LEVEL (01 MIN 11 14' mahmrun of 12' forward for proper drainaa. See Ins: dat on Mania for IMPORTANT wait 1I2 MAX I I/ / 1/r MAX — _ _ support details an hafIDnhal appfiabors. r 1 Pour des app caliors de (ha ascendent at descendant, la fermata dos Abe Instate de T n beau au i ncenee a pas plus de 1/2' du nNea . Pour tie haimrdale, la foue'se dolt etre irdnAe entre n 1/4 a rreerrun 1 du rmeau pour le dIei m rninamh nage UPFLOW OR FRONT aeppppm�opp En ces d'ushallatiah at posilion h rimrdale, caaulter les rensegnerente DOW NFLOW HORIZONTAL INPCHTANTS sun le support dais )e renal dtrsta0atibn MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION TMs furnace is appraed fa (PRDN, DOWNPLGNwd AU. POSRIONS: HORI217NDIL rrstallahore * Mttnm front dearer= for aewa 33 inches (760rrh. Ca le rarna est awroune par rinstaflattri KIRIENALE t t 140 sim bastes nnire 1 inch bait dseaee to wnaalide Medals. at b dratalan dair VERS. LE MLR et VEFLS LE BPS. DOWNFLOW POSmONS: t For installation an c ntuslide etas only Mal installed m spa ial base Nor KrA980201ALL., (bit Clearance arrays 1• Les Maas de degagemers Assertiy, Part Na Q 5 or QC9, a Qil Casing, Pan Na KCACG do not range with o necharge pas aver HORIZONTAL POSm0NS: furnace aiOPmian raiatalon de la Lire naiad is pams9dearty belveah fireSEarned b/ eYasedles of tap had two sides of furnace arrester d•alr dead jacket, and didrg jeists, studs, or (raring § oeaanesho+ I isfor airWetardairoDdmde. tt cc, e ° Q r 0 120 ad 140smftmaoesregat e1Art toter nducetocmtusti antedate A R - R C e DEGAGEMENT MINIMUM EN POUCES AVEC ELEMENTS DE CONSTRUCTION COMBUSTIBLES h ERE FoPP C. t� C° POUR TOUSLESPOSiriONS: a °J F p °P t * ft tuftauan (30 pa) li3rtetisn r� • tt FirfeytarraLsesde140taiile ,1po (Mime d n les estrecols L ErhEFV • aurarnaa pE F ET 1 C E POUR LA POSITION COURANT DESCENDANT: s'. Ee AyA 1 EN3 Pour t Iirnstallati msla planar ombuatidesaz/mt3t hdmaaiselabase�� Ae Otte 0° A02148 m l am KGAS80e01AL , stie serreren p rf 4005 sou K5, at leader de woman, race 3 re KG010: POUR LA POSMON HORIZONTALE: Le coated nest rpaermrthss quanta las Vies tamales par les irtasedias du Besse d des deuxo5b a de to Marisa da is fpurese, at ties seines, des mutants a de b datpele cb bAlbret. vent clearance to La dstaoe Maple =care raffrenite duhryau d'ad'de d f'edNmta du tu)au de eels dew Or carrdatitias 0'. 0 War les foumaises la 120 et 140 taite,1 pp (2"mn) dgerart Bas net liar c rti tlISes eat lisps Oeararce In lades t 0 0 (po) Demonist arrest s Ddeganet (po). cones abec eartaa hues 324999 -201 REV. D (LIT TOP) I Controls— Thermostats and Zoning Non - Programmable Thermostat Selection TSTATBBNAC01 - For use with 1 -spd. Alr Conditioner - deg. F /C, Auto Changeover TSTATBBNHP01 - For use with 1 -spd. Air Conditioner - deg. F /C, Auto Changeover TSTATBBN2S01 -B• For use with 2 -spd. Air Conditioner - deg. F /C, Auto Changeover TSTATBBBAC01 -B For use with 1-spd. Air Conditioner - deg. F/C TSTATBBPRH01 - B*• For multi / stage configurations - deg. F /C, Auto Changeover/Temperature and Humidity Control ' Model HP and 2S thermostat must be field converted to air conditioner operation. *•Thermidistat Control is versatile and can be configured for multiple use and staging, it must be configured for each specific application. Programmable Thermostat Selection TSTATBBPAC01 - For use with 1 -spd. Alr Conditioner - deg. F /C, Auto Changeover, 7 -Day Programmable TSTATBBPHP01 - B• For use with 1 Air Conditioner - deg. F /C, Auto Changeover, 7 - Day Programmable TSTATBBP2S01 - For use with 2-spd. Air Conditioner - deg. F /C, Auto Changeover, 7 -Day Programmable TSTATBBSAC01 For use with 1 -spd. Air Conditioner - deg. F /C, 5 - 2 Day Programmable TSTATBBPDF01 - B•* For use with multi -stage applications - deg. F /C, Auto Changeover, 7 -Day Programmable TSTATBBPRH01 -B*** For multi -use / stage configurations - deg. F /C, Auto Changeover, 7 -Day Programmable/Temperature and Humidity Control • Model HP and 2S thermostat must be field converted to air conditioner operation, **Dual Fuel thermostat is used with furnace and heat pump application * * *Thermidistat Control can be configured for multiple use and staging, it must be configured for each specific application. Zoning Control Selection ZONEKIT2ZBDP Zone Perfect Two-Zone kit ZONEBB2KIT01 - Zone Perfect Plus 2 -Zone kit/Temperature and Humidity Control ZONEBB4KiT01 - Zone Perfect Plus 4 -Zone kit/Temperature and Humidity Control ZONEBB8KIT01 - Zone Perfect Plus 8-Zone kit/Temperature and Humidity Control • —3— I SPECIFICATIONS UNIT SIZE 024040 036040 024060 036060 048060 036080 RATINGS AND PERFORMANCE Input Btuh• 40,000 40,000 60,000 60,000 60,000 80,000 Output Capacityt ICS Upflow 38,000 38,000 56,000 56,000 56,000 75,000 ` (Shaded capacities are Downflow 38 ,000 38,000 56,000 56,000 56,000 75,000 specified on rating plate) Horizontal 38 ,000 38,000 56,000 56,000 56,000 74,000 AFUE %t Upflow 94.3 95.5 93.1 93.1 93.1 93.1 _ Nonweatherized ICS Downflow 92.9 94.0 91.7 91.7 91.7 91.7 Horizontal 93.7 94.9 92.5 92.5 92.5 92.5 Certified Temperature Rise Range °F 30-60 15-45 45-75 30-60 20-50 40-70 Certified External Static Pressure Heating 0.10 0.10 0.12 0.12 0.12 0.15 Cooling 0.50 0.50 0.50 0.50 0.50 0.50 Airflow CFM# Heating 850 1125 885 1065 1320 1190 Cooling 895 1215 900 1200 1545 1245 ELECTRICAL Unit Volts- Hertz -Phase 115 -60• -1 Operating Voltage Range Min-Max** 104 -127 Maximum Unit Amps 6.1 7.3 6.1 7.1 9.5 7.6 Unit Ampacitytt 8.4 10.0 8.4 9.8 12.8 10.4 Minimum Wire Size 14 14 14 14 14 14 Maximum Wire Length (Ft)## 44 37 44 38 29 36 Maximum Fuse Size or Ckt Bkr Amps (Time -Delay Fuse Recommended) 15 15 15 15 15 15 Transformer (24v) 40va External Control Heating 12va • Power Available Cooling 21 va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control (Off Delay) Selectable 90, 120, 150, or 180 Sec Burners (Monoport) 2 I 2 I 3 [ 3 I 3 I 4 - Gas Connection Size 1 /2 -In. NPT GAS CONTROLS Gas Valve (Redundant) Manufacturer White- Rodgers Min Inlet Pressure (In. wc) 4.5 (Natural Gas) Max Inlet Pressure (In. wc) 13.6 (Natural Gas) Ignition Device Hot Surface BLOWER DATA Direct -Drive Motor HP (Permanent Split Capacitor) 1/5 1/3 1/5 1/3 1/2 1/3 Motor Full Load Amps 4.9 5.8 4.9 5.8 7.9 5.8 RPM (Nominal)- Speeds 1075-3 1075 -4 1075-3 1075-4 Blower Wheel Diameter x Width (In.) 10 x 6 10 x 7 10 x 6 10 x 7 I 11 x 8 I 10x7 Filter Size (In.)- Permanent Washable (1) 16 x 25 x 1 FACTORY - AUTHORIZED AND LISTED, DEALER INSTALLED OPTIONS Gas Conversion Kit- Natural - to-Propane KGANP2901ALL Gas Conversion Kit - Propane - to-Natural KGAPN2301ALL Twinning Kit - Upflow ONLY N/A IKGATW0601HSII N/A Manufactured (Mobile) Home Kit KGAMH0101 KIT Downflow Base*** KGASB0201ALL Vent Termination Kit (Bracket Only for 2 Pipes) 2- in.- KGAVT0101 BRA 3- In.- KGAVT0201 BRA Concentric Vent Termination Kit (Single Exit) 2- In.- KGAVT0501CVT 3- in.- KGAVT0601CVT Condensate Freeze Protection Kit KGAHT0101CFP Electronic/Mechanical Air Cleaner Model AIRA, 902B, MACA, or FILCAB Humidifier Model HUM Heat/Energy Recovery Ventilator Model HRV, ERV See notes on page 5. -4- 1 SPECIFICATIONS Continued UNIT SIZE 048080 060080 048100 060100 060120 060140 RATINGS AND PERFORMANCE Input Btuh* 80,000 80,000 100,000 100,000 120,000 138,000 ' Output Capacityt ICS Upflow 75,000 75,000 94,000 94,000 113,000 129,000 (Shaded capacities are Downflow 75,000 75,000 94,000 94,000 113,000 129,000 specified on rating plate Horizontal 75,000 75,000 93,000 93,000 112,000 128,000 AFUE %t Upflow 93.1 93.1 93.1 93.1 93.1 92.8 Nonweatherized ICS Downflow 91.7 91.7 91.7 91.7 91.7 91.2 Horizontal 92.5 92.5 92.5 92.5 92.5 92.0 Certified Temperature Rise Range °F 30-60 20-50 45-75 30-60 40-70 50-80 Certified External Static Pressure Heating 0.15 0.15 0.20 0.20 0.20 0.20 Cooling 0.50 0.50 0.50 0.50 0.50 0.50 Airflow CFM# Heating 1285 1785 1315 1690 1720 1970 Cooling 1525 1925 1570 1930 2000 1990 ELECTRICAL Unit Volts- Hertz -Phase 115 -60- -1 Operating Voltage Range Min - .Max•• 104 -127 Maximum Unit Amps 10.0 14.1 10.2 14.8 14.8 14.3 Unit Ampacityrt 13.4 18.4 13.5 19.3 19.1 18.8 Minimum Wire Size 14 12 14 12 12 12 Maximum Wire Length (Ft)## 28 31 27 30 30 30 Maximum Fuse or Ckt Bkr Amps (Time -Delay Type Recommended) 15 20 15 20 20 20 Transformer (24v) 40va External Control Heating 12va Power Available Cooling 21va Air Conditioning Blower Relay Standard CONTROLS 'Limit Control SPST Heating Blower Control (Off Delay) Selectable 90, 120, 150, or 180 Sec Burners (Monoport) 4 I 4 I 5 I 5 I 6 I 6 Gas Connection Size 1/2 -In. NPT GAS CONTROLS Gas Valve (Redundant) Manufacturer White - Rodgers Min Inlet Pressure (In. wc) 4.5 (Natural Gas) Max Inlet Pressure (In. wc) 13.6 (Natural Gas) Ignition Device Hot Surface BLOWER DATA Direct -Drive Motor HP (Permanent Split Capacitor) 1/2 3/4 1/2 3/4 3/4 3/4 Motor Full Load Amps 7.9 11.1 7.9 11.1 11.1 11.1 RPM (Nominal)- Speeds 1075-4 Blower Wheel Diameter x Width (In.) 11 x 8 11 x 10 I 11 x 8 I 11 x 10 11 x 10 I 11 x 10 Fitter Size (In.)- Permanent Washable (1) 16 x 25 x 1 ( 1 ) 20 x25 x 1 (1) 24 x 25 x 1 FACTORY - AUTHORIZED AND LISTED. DEALER INSTALLED OPTIONS Gas Conversion Kit- Natural - to-Propane KGANP2901ALL Gas Conversion Kit - Propane - to-Natural KGAPN2301 ALL Twinning Kit - Upflow ONLY KGATWO601 HSI N/A Manufactured (Mobile) Home Kit KGAMH0101 KIT N/A Downflow Base*** KGASB0201ALL Vent Termination Kit (Bracket Only for 2 Pipes) 2- in.- KGAVT0101 BRA 3- in.- KGAVT0201 BRA Concentric Vent Termination Kit (Single Exit) 2- in.- KGAVT0501CVT 3- In.- KGAVT0601CVT Condensate Freeze Protection Kit KGAHT0101CFP Electronic/Mechanical Air Cleaner Model AIRA, 902B, MACA, or FILCAB Humidifier Model HUM Heat/Energy Recovery Ventilator Model HRV, ERV • Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Canada, derate the unit 5% from 2000 to 4500 ft above sea level. t Capacity and AFUE in accordance with U.S. Government DOE test procedures effective November 10, 1997. # • Airflow shown is for bottom only return -air supply with factory- supplied 1 -in. washable filter(s). • For air delivery above 1800 CFM, see Air Delivery table for other options. • An airflow reduction of up to 7% may occur when using the factory- specified 4 5/16 -inch wide, high efficiency media filter. • For best furnace efficiency when using the 4 5/16 -inch wide media filter, adjust the blower speed tap to near the mid -point of the rise range. •• Permissible voltage limits for proper furnace operation. . tt Unit ampacity = 125% of largest component's full load amps plus 100% of all other potential operating components (EAC, humidifier, etc.). ## Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop. ••' Required for installation on combustible floors when no coil box is used, or when any coil box other than a Bryant CD5 or CK5 cased coil is used. N/A -Not applicable ICS - Isolated Combustion System • -5- • -, COMBUSTION -AIR AND VENT PIPING MAXIMUM ALLOWABLE PIPE LENGTH (Fr) ALTITUDE ABOVE SEA PIPE DIA NUMBER OF 90° ELBOWS • LEVEL (FT) UNIT SIZE TERMINATION TYPE (IN.)* 1 2 3 4 6 6 1 5 NA NA NA NA NA 024040 2 Pipe or 2 -In. Concentric 1 -1/2 70 • 70 65 60 60 55 • 036040 2 70 70 70 70 70 70 • 024060 1 -1/2 20 15 10 5 NA NA 036060 2 Pipe or 2 -In. Concentric 048060 2 70 70 70 70 70 70 • 036080 1 -1/2 10 NA NA NA NA NA 048080 2 Pipe or 2 -In. Concentric 2 55 50 35 30 30 20 060080 2 -1/2 70 70 70 70 70 70 0 to 2000 2 5 NA NA NA NA NA 048100 2 Pipe or 3-In. Concentric 2 -1/2 40 30 20 20 10 NA 060100 3 70 70 70 70 70 70 2 -1/2 one disk 10 NA NA NA NA NA 060120 2 Pipe or 3-In. Concentric 3t 45 40 35 30 25 20 3t no disk 70 70 70 70 70 70 2.1/2 one disk 5 NA NA NA NA NA 060140 2 Pipe or 3-In. Concentric 3t one disk 40 35 30 25 20 15 3t no disk 60 56 52 48 44 40 4t no disk 70 70 70 70 70 70 024040 1 -1/2 67 62 57 52 52 47 036040 2 Pipe or 2 -In. Concentric 2 70 70 70 70 70 70 024060 1 -1/2 17 12 7 NA NA NA 036060 2 Pipe or 2 -In. Concentric 048060 2 70 67 66 61 61 61 036080 2 49 44 30 25 25 15 u . 048080 2 Pipe or 2 -In. Concentric 2 -1/2 70 70 70 70 70 70 060080 2001 to 3000 048100 2 -1/2 35 26 16 16 6 NA 060100 2 Pipe or 3 -In. Concentric 3 70 70 70 70 66 61 3 14 9 NA NA NA NA 060120 2 Pipe or 3-In. Concentric 3t no disk 70 70 63 56 50 43 4t no disk 70 70 70 70 70 70 at one disk 20 15 10 5 NA NA 060140 2 Pipe of 3-In. Concentric 3t no disk 39 35 31 27 23 19 41 no disk 70 70 70 70 70 70 024040 2 Pipe or 2 -In. Concentric 1 -1/2 64 59 54 49 48 43 036040 2 70 70 70 70 70 70 024060 1 -1/2 16 11 6 NA NA NA 036060 2 Pipe or 2 -In. Concentric 048060 2 68 63 62 57 57 56 036080 2 46 41 28 23 22 13 048080 2 Pipe or 2 -In. Concentric 2-/12 70 70 70 70 70 70 3001 to 4000 060080 048100 2-1/2 33 24 15 14 5 NA 060100 2 Pipe or 3 -In. Concentric 3 70 70 70 66 61 56 060120 2 Pipe or 3-In. Concentric 3t no disk 65 58 51 44 38 31 4t no disk 70 70 70 70 70 70 3t one disk 11 6 NA NA NA NA 060140 2 Pipe or 3-In. Concentric 3• no disk 30 26 22 18 14 10 41 no disk 70 70 70 70 70 70 024040 2 Pipe or 2 -In. Concentric 1-1/2 60 55 50 45 44 39 036040 2 70 70 70 70 70 70 024060 1-1/2 15 10 5 NA NA NA 036060 2 Pipe or 2 -In. Concentric 048060 2 64 59 58 53 52 52 036080 2 44 39 26 21 20 11 048080 2 Pipe or 2 -in Concentric 4001 to 5000$ 060080 2 -1/2 70 70 70 70 70 70 048100 2 -1/2 31 22 13 12 NA NA 060100 2 Pipe or 3-In. Concentric 3 70 70 67 62 57 52 060120 2 Pipe or 3-In. Concentric 3t no disk 53 46 40 33 26 20 41' no disk 70 70 70 70 70 70 060140 2 Pipe or 3-In. Concentric 3fi no disk 21 17 13 9 5 NA 41' no disk 69 64 59 54 49 44 See notes on page 7. -6- • MAXIMUM ALLOWABLE PIPE LENGTH (Fr) Continued ALTITUDE ABOVE SEA PIPE DIA NUMBER OF 90° ELBOWS LEVEL (F1) UNIT SIZE TERMINATION TYPE (IN.)* 1 2 3 4 5 6 024040 1 -1/2 57 52 47 42 40 35 2 Pipe or 2 -In. Concentric 036040 2 70 70 70 70 70 70 024060 1 -1/2 14 9 NA NA NA NA 036060 2 Pipe or 2 -In. Concentric 048060 2 60 55 54 49 48 47 036080 2 41 36 23 18 17 8 048080 2 Pipe or 2 -In. Concentric 5001 to 6000* 060080 2 -1/2 70 70 70 70 70 70 048100 2 -1/2 29 21 12 11 NA NA 060100 2 Pipe or 3-in Concentric 3 70 87 62 57 52 47 060120 2 Pipe or 3-In. Concentric 331 no disk 42 35 29 22 15 9 4t no disk 70 70 70 70 70 70 at 060140 2 Pipe or 3-In. Concentric no disk 12 8 NA NA NA NA 41 no disk 42 37 32 27 22 17 024040 1 -1/2 53 48 43 38 37 32 2 Pipe or 2 -In. Concentric 036040 2 70 70 68 67 66 64 024060 1 -1/2 13 8 NA NA NA NA 036060 2 Pipe or 2 -In. Concentric 048060 2 57 52 50 45 44 43 036080 2 38 33 21 16 15 6 6001 to 7000* 048080 2 Pipe or 2 -In. Concentric 2-1/2 70 70 68 67 66 64 060080 048100 2 -1/2 27 19 10 9 NA NA 2 Pipe or 3-In. Concentric 3 68 63 58 53 48 43 060120 2 Pipe or 3-In. Concentric at no disk 31 24 18 11 NA NA 41 no disk 70 70 70 70 67 62 060140 2 Pipe or 3-In. Concentric 4t no disk 17 12 7 NA NA NA 024040 1 -1/2 49 44 39 34 33 28 2Pipeor2- In.Concentric 036040 2 66 65 63 62 60 59 024060 1 -1/2 12 7 NA NA NA NA 036060 2 Pipe or 2 -In. Concentric 048060 2 53 48 46 41 40 38 - 036080 2 36 31 19 14 12 NA 7001 to 8000* 048080 2 Pipe or 2 -In. Concentric 2 -1/2 66 65 63 62 60 59 060080 048100 2 -1/2 25 17 8 7 NA NA 060100 2 Pipe or 3 -In. Concentric 3 63 58 53 48 43 38 at 060120 2 Pipe or 3-In. Concentric no disk 20 13 7 NA NA NA 4t no disk 61 56 51 _ 46 41 36 060140 NA 024040 1-1/2 46 41 36 31 29 24 036040 2 Pipe or 2 -In. Concentric 2 62 60 58 56 55 53 024060 1 -1/2 11 6 NA NA NA NA 036060 2 Pipe or 2 -In. Concentric 048060 2 49 44 42 37 35 34 036080 2 33 28 17 12 10 NA 8001 to 9000* 048080 2 Pipe or 2 -In. Concentric 2-1/2 62 60 58 56 55 53 060080 048100 2 -1/2 23 15 7 5 NA NA 060100 2 Pipe or 3 -In. Concentric 3 59 54 49 44 39 34 ! 060120 2 Pipe or 3-In. Concentric 3t no disk 10 NA NA NA NA NA 4t no disk 35 30 25 20 15 10 060140 NA 024040 1-1/2 42 37 32 27 25 20 036040 2 Pipe or 2 -In. Concentric 2 57 55 53 51 49 47 024060 036060 2 Pipe or 2 -In. Concentric 2 45 40 38 33 31 29 048060 9001 to 036080 2 30 25 14 9 7 NA 10,000* 048080 2 Pipe or 2 -In. Concentric 2 -1/2 57 55 53 51 49 47 060080 048100 2-1/2 21 13 5 NA NA NA 060100 2 Pipe or 3-In. Concentric 3 y4 49 44 39 34 29 060120 2 Pipe or 3-In. Concentric 4t no disk 10 5 NA NA NA NA • 060140 NA • Disk usage — Unless otherwise specified, use perforated disk assembly (factory- supplied in loose parts bag). If one disk is stated, separate 2 halves of ' perforated disk assembly and use shouldered disk half. When using shouldered disk half, install screen side toward inlet box. t Wide radius elbow. * Vent sizing for Canadian installations over 4500 ft (1370m) above sea level are subject to acceptance by the local authorities having jurisdiction. NA—Not Allowed; pressure switch will not make. NOTES: 1. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur. 2. Size both the combustion -air and vent pipe independently, then use the larger diameter for both pipes. 3. Assume two 45° elbows equal one 90° elbow. Long radius elbows are desirable and may be required in some cases. 4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count. 5. The minimum pipe length is 5 ft for all applications. 6. Use 3 in. diameter vent termination kit for installations requiring 4 in. diameter pipe —7— MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* WINTER DESIGN MAX PIPE TEMPERATURE DIAMETER WITHOUT WITH 3/8 -IN. OR UNIT SIZE ( °F) (IN.) INSULATION THICKER INSULATIONt • 20 1 -1/2 51 70 024040 0 1-1/2 28 70 036040 • —20 1 -1/2 16 70 024060 20 2 65 70 036060 0 2 35 70 048060 —20 2 20 70 036080 20 2-1/2 70 70 048080 0 2 -1/2 47 70 060080 —20 2 -1/2 28 70 20 3 70 70 048100 0 3 50 70 060100 —20 3 28 70 20 4 70 70 060120 0 4 48 70 —20 4 23 70 20 4 70 70 060140 0 4 57 70 —20 4 30 70 • Pipe length (ft) specified for maximum vent pipe lengths located in unconditioned spaces. Vent pipes located in unconditioned space cannot exceed the total allowable pipe length as specified in Maximum Allowable Pipe Length table. t Insulation thickness based on R value of 3.5 per in. a -8- CONDENSATE TRAP BLOWER SHELF FURNACE CONDENSATE DOOR TRAP CONDENSATE FURNACE ' TRAP (INSIDE) FURNACE DOOR FURNACE . SIDE SIDE raria r---- .T. - 4 R 4 I e= � � 5 1 5 T4 T T r � 4 • � � � LF If 1 1 ' - �— 1 a 11/2 FIELD DRAIN 1 �a FIELD N / 1 DRAIN ALTERNATE DRAIN CONN CONN TUBE LOCATION CONDENSATE TRAP SIDE VIEW FRONT VIEW END VIEW FRONT VIEW DRAIN TUBE LOCATION DOWNFLOW AND ALTERNATE HORIZONTAL UPFLOW APPLICATIONS EXTERNAL UPFLOW APPLICATIONS APPLICATIONS SLOT FOR SCREW • HORIZONTAL APPLICATION (OPTIONAL) '/4 OD COLLECTOR BOX TO • 1 1/2 TRAP RELIEF PORT —" INDUCER OD 1/2 � �� INDUCER HOUSING ''''(('' (.1m:. DRAIN CONNECTION 3/4 * � S.b OD COLLECTOR BOX 1 71/8 L DRAIN CONNECTION a r SCREW HOLE FOR UPFLOW OR 1 �Ya LOWA - 1 PLICATIONS WIRE TIE 77/8 —el _ I 1 /a f I GUIDES 2 ' -IN. PVC OR CPVC (WHEN USED) FRONT VIEW SIDE VIEW A93026 DESIGN EFFICIENCY 0 RATING 4, ( CERTIFIED am GNGIFIED MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. �`ve� Cal'. •re 3 .. r —,AltZeir . 413 d As an ENERGY STAR® 4o Partner, Bryant Heating & Cooling Systems has deter - REGISTERED QUALITY SYSTEM mined that this product meets the ENERGY STAR® guide- These products are engineered and manufactured lines for energy efficiency. under an ISO 9001 registered quality system. —9— I ACCESSORIES • CONCENTRIC VENT MEDIA FILTER CABINET B IN. DIA PVC ��, VENT /EXHAUST F 24 1,. Beta I. 23 v I I�owxa 11 . I 111 . . O t ■ immil • • • I O A . . 11 ; I __ ___1flT ac.s1/1s ♦ 23v Cassino Saw gob I.6—$1A 11/2 -16— D Medal Carnet A B A 1 I I . ..., te' 17• 1s• B IN. DIA PVC 20' 2r 20• INTAKE/COMBUSTION AIR 24• 25• 24• A97110 A02183 NOTE: See furnace Installation Instructions when venting multiple furnaces near each other. DIMENSIONS (In.) PART NO. A• B C Dt E F I. KGAVT0501CVT 33-3/8 2 3-1/2 16-5/8 6 -1/4 5-3/4 KGAVT0601CVT 38 -7/8 3 4 -1/2 21.1/8 7 -3/8 6-1/2 • Dimension A will change accordingly as dimension D is lengthened or shortened. t Dimension D may be lengthened to 60 in. maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in. minimum. ACCESSORY DOWNFLOW SUBBASE LOCATING TAB ,e. 1 /4" TYP °— r 1' • PLENUM r � r OPENING I B 1 /� • LOCATTABB \\V 1.1.1 / , \� FACTORY-SUPPLIED \� j �� C ` lid « r°' -,, FIELD - INSTALLED ' INSULATION A88207 A97427 Disassembled Assembled FURNACE PLENUM OPENING* FLOOR OPENING HOLE NO. CASING - FOR WIDTH WIDTH FURNACE IN DOWNFLOW APPLICATION A B C D ADJUSTMENT 17.1/2 Furnace with or without CD5 or CK5 Coil 15-1/8 19 16-3/4 20-3/8 3 Assembly or KCAKC Coil Box 21 Furnace with or without CD5 or CK5 Coil 18-5/8 19 20-1/4 20-3/8 2 Assembly or KCAKC Coil Box 24 -1/2 Furnace with or without CD5 or CK5 Coil 22 -1/8 19 23-3/4 20 -3/8 1 Assembly or KCAKC Coil Box • The plenum should be constructed 1/4 in. smaller in width and depth than the plenum dimensions shown above. —10— AIR DELIVERY —CFM (With Filter)* . RETURN -AIR EXTERNAL STATIC PRESSURE (In. wc) UNIT SIZE SUPPLY SPEED 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 • 1 side High 1075 1040 995 945 895 840 760 670 024040 or Med -Low 850 825 780 740 685 635 560 480 . bottom Low 740 700 650 620 565 515 455 385 1 side High 1470 1415 1400 1285 1215 1120 995 890 036040 or Med -1igh 1315 1280 1235 1180 1115 1035 930 825 • bottom Med -Low 1125 1110 1085 1045 990 915 830 740 Low 930 925 910 850 830 770 705 635 1 side High 1100 1065 1005 945 900 805 730 610 024060 or Med -Low 890 865 810 765 705 620 540 475 bottom Low 745 710 670 625 565 505 425 360 1 side High 1430 1375 1325 1275 1200 1135 1040 935 036060 or Med -1igh 1270 1260 1215 1160 1105 1035 950 850 bottom Med -Low 1070 1055 1045 1015 975 920 850 750 Low 915 895 885 865 840 800 720 650 1side High 1700 1695 1640 1580 1545 1450 1380 1310 048060 or Med -High 1500 1465 1435 1385 1355 1300 1250 1185 bottom Med -Low 1325 1295 1265 1230 1190 1150 1105 1050 Low 1205 1170 1145 1110 1080 1035 990 950 1side High 1535 1470 1405 1330 1245 1160 1065 935 036080 or Med -High 1395 1350 1300 1225 1155 1080 985 880 bottom Med -Low 1200 1175 1125 1065 1030 970 890 780 Low 1040 1020 990 960 910 860 785 680 1 side High 1750 1685 1635 1575 1525 1445 1380 1310 048080 or Med -High 1495 1455 1405 1355 1305 1250 1185 1120 bottom Med -Low 1310 1260 1225 1170 1125 1095 1040 980 Low 1135 1105 1075 1040 995 995 910 860 1 side High 2200 2175 2085 2025 1925 1820 1735 1635 or Medigh 2100 2025 1945 1865 1785 1700 1620 1540 bottom Med -Low 1815 1760 1720 1670 1620 1550 1480 1405 060080 Low 1560 1555 1515 1460 1435 1390 1340 1270 both sides or High 2360 2280 2210 2130 2035 1960 1875 1790 1 side and Med -High 1965 1925 1870 1830 1760 1710 1670 1575 bottom 1 side High 1740 1705 1660 1615 1570 1500 1425 1355 048100 or Med -High 1500 1470 1445 1410 1375 1330 1280 1210 bottom Med -Low 1340 1315 1300 1270 1235 1200 1140 1095 Low 1195 1175 1165 1130 1100 1070 1030 975 1 side High 2250 2175 2090 2020 1930 1855 1760 1670 or Med -High 2020 1950 1900 1840 1790 1710 1640 1545 bottom Med -Low 1725 1690 1660 1630 1575 1520 1460 1370 060100 Low 1490 1480 1460 1440 1380 1340 1295 1230 both sides or High 2360 2315 2265 2200 2130 2055 1965 1890 1 side and Med -High 1960 1940 1930 1900 1850 1800 1740 1660 bottom High 2350 2250 2160 2070 2000 1885 1790 1635 bottom Med -High 2100 2015 1955 1875 1810 1710 1650 1540 only Med -Low 1770 1720 1675 1620 1575 1515 1450 1365 Low 1545 1520 1465 1415 1365 1325 1265 1185 060120 both sides or High 2435 2360 2285 2220 2130 2050 1965 1875 1 side and Med -High 2040 2000 1950 1905 1835 1790 1725 1650 bottom 1 side only High 2255 2190 2115 2045 1965 1890 1800 1710 Medi g h 1985 1930 1890 1840 1780 1720 1645 1560 High 2285 2210 2140 2065 1990 1910 1830 1745 bottom only Med -High 2020 1970 1920 1870 1805 1730 1660 1590 Med -Low 1675 1650 1620 1590 1560 1510 1450 1390 Low 1460 1445 1430 1400 1370 1320 1275 1230 060140 both sides or High 2310 2255 2185 2120 2045 1965 1880 1800 1 side and Med -High 1975 1945 1900 1860 1835 1775 1720 1640 bottom 1 side only High 2140 2080 2025 1945 1875 1795 1725 1625 Medi g h 1930 1850 1800 1740 1725 1660 1580 1495 t • Airflow shown is for bottom only return -air supply with factory- supplied 1 -in. washable filter(s). • For air delivery above 1800 CFM, see Air Delivery table for other options. • An airflow reduction of up to 7% may occur when using the factory- specified 4 5/16 -inch wide, high efficiency media filter. • For best furnace efficiency when using the 4 5/16 -inch wide media filter, adjust the blower speed tap to near the mid -point of the rise range. • For horizontal and downflow applications, use "1 side or bottom" or "bottom only" as an airflow reference. —11— • • SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE b r y a n t WITH INSTALLATION INSTRUCTIONS Cancels: PDS 350M.40.9 Heating& Coefmg Systems - 0 2002 Bryant Heating & Cooling Systems, 7310 W. Moms St., Indianapolis, IN 46231 — 12— PRINTED IN U.S.A. Catalog No. 5235-003 7 -02