Loading...
Specifications E' :.4CIC.dI V ED JUN 07 2012 • CTTY OFTIGARD BUILDING DIVISION • TIGARD PROMENADE PETCO 15660 SW PACIFFIC HWY Submittals For: TIGARD , OR. 97224 Submitted By: T & L Communications, Inc. P.O. Box 87387 Vancouver, WA 98661 360- 737 -9725T 360 - 737 -9648 fax ticomm @wa- net.com 37 -428 CLE Oregon Contractor 67787 " ' "CCB Number 6981:::..:: Metro Number - • 684 LEA - Supervising Journeyman Larry E. Bushaw CITY,pF�ARD Approved [ y� Conditionally Approved [ ] See Letter to: Follow [ ] Atta ed. . „ Pem'ritNumber: Zot Address: 66 - _- By: �& Date: a m Approved plans shall be on job site. • OFFICE COPY — Global Project Values: itA SILENT Project Name:ITIGARD PROMENADE PETCO I Standby Hours:( 24 KNIGHT Project ID:118617 -12 I Alarm Mins:I 5 Prepared By:IT&L COMMUNICATIONS.INC I Derating Factor:( 1.2 I 5499 Power Expander Calculations Date:15/30 /2012 I Voltage Drop Warning Threshold % Version 02.18.09 I 10 I Panel ID: 15499 I Model: 5499 Power Expander Max NAC Current: 3.0 Amps Location: (ELECTRIC ROOM I Volts: 24 VDC Max Panel Current: 9 0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5499 5499 Pwr Module 1 1 0.075 0.205 NAC #1 5499 Circuit 1 0.000 0.462 #14 Solid 3.07 200 1.23 19.83 NAC #2 5499 Circuit 2 0.000 1.547 #14 Solid 3.07 200 1.23 18.50 NAC #3 5499 Circuit 3 0.000 0.221 #14 Solid 3.07 30 0.18 20.36 NAC #4 5499 Circuit 4 0.000 0.000 #14 Solid 3.07 0.00 20.40 Aux 5499 Aux Power Out 0.000 0 000 #12 Solid 1.59 0.00 20.40 Total Standby Current (Amps) 0.075 2.435 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 0.203 Total Alarm AH Required Total Combined AH Required 2.00 Wire resistances are based upon an ambient temperature of 120 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.40 • Configure Circuits l I r Print Page , ■ SILENT fla IN�(:�� I Circuit Configuration • Project Information Project Name: TIGARD PROMENADE PETCO Project ID: 18617 -12 Prepared By: T &L COMMUNICATIONS.INC Date: 5/30/2012 Ckt. Number. NAC #1 Panel ID: 5499 Ckt. Name: 5499 Circuit 1 Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby _ Alarm Standby Alarm 7 System Sensor S /SC Strobe (15cd) 0.000 0.066 0.000 0.462 Unused 0.000 0.000 0 000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 _ 0.462 Ckt. Number. NAC #2 Panel ID: 5499 Ckt. Name: 5499 Circuit 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby _ Alarm 7 System Sensor P2/PC2 Horn /Strobe (110cd) 0.000 0.221 0.000 1.547 Unused 0.000 0.000 0 000 0.000 Unused 0.000 0.000 0.000 0.000 • Unused _ 0.000 0.000 !_ 0.000 _ 0.000 .• , •. • • 0.000 0.000 _ : • Totals 0.000 1.547 Ckt. Number: NAC #3 Panel ID: 5499 Ckt. Name: 5499 Circuit 3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor P2 /PC2 Horn /Strobe (110cd) 0 000 0.221 0.000 0.221 Unused 0 000 0.000 0.000 0 000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.221 Ckt. Number NAC #4 Panel ID: 5499 Ckt. Name: 5499 Circuit 4 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total _ Standby Alarm Standby Alarm Unused 0 000 0.000 0 000 0.000 Unused 0.000 0.000 0.000 0.000 • Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 • TIGARD PROMENADE PETCO • 15 15 15- 15 15 15. 15 . `� \ \/ [s S S I S [[ . _.. ^ . y NAC -1 EOL r, 110 110 110 110 110 110 110 SILENT KNIGHT 5499 _ HS HS HS HS HS NAC -2 EOL TO NAC 2.OF 5208 FACP new ,2WAMP 12'17A2.1P • • TIGARD PROMENADE • 110 WATERFLOW ZONE1 • NAC -1 HORN • STROBE __ TAMPER TAMPER ZONE2 • .SMOKE • j [ KNIGHT _ 1 Q DETECTOR. ZONES • TO 5499 NAC PANEL FOR PETCO 5208 NAC2 - PULL STATION ZONE4 12V7 AMP 12W AMP DEC. 120 VAC I UCT DETECTOR ZONES 2- PHONE LINES DUCT DETECTOR ZONES DUCT DETECTOR ZONE7 i . • TIGARD PROMENADE LEDGEND WATERFLOW WATERFLOW FOR ENTIRE BUILDING TAMPER SYSTEM TAMPERS SMOKE DETECTOR SMOKE DETECTOR ABOVE FACP PULL STATION r P STATION : A T RISER • 110 ' HORN OUTSIDE HORN STROBE STROBE DUCT DETECTOR DUCT DETEC TORS FOR PETCO SILENT KNIGHT 5208 REPLACMENT PANEL DIALER FOR SPRINKLER MONITORING 12V7 MAP 12V7 AMP 9 FIRE ALARM CONTROL PANEL V 410 SILENT Model 5208 KNIGHT Fire Alarm Control Panel with Digital Communicator by Honeywell The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK -5208 is a microprocessor based control panel with built -in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK -5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK -5208 delivers the performance to handle your installation. Features • Built -in synchronization for • (Style B) appliances from AMSECO ®, T— Class A (Style Class or Class B and 2 pp Class A (Style D) or Class s B (Style Gentex®, Faraday, System Sensor®, B) zones, expandable to 30 zones and Wheelock® • Supervised zone expanders and I/O • Programmable date settings for i modules can be mounted remotely Daylight Saving Time —•- from the main control panel • Clock source setting options for 50 • • • Event History Buffer (150 events) Hz, 60 Hz, or internal (uses the wi === • 0 with date /time stamp panel's internal clock) - • All zones are compatible with 2- or Specifications 4 -wire detectors alt • 8 selectable /programmable output Operating Voltage: 24 VDC patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load. 6 Amp • Built -in Digital Alarm Communicator Current Draw: Transmitter (DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm 460 mA • 4 programmable general purpose Flush Mounting Dimensions: p._. relays Height 24.75" (62.9 cm) • Programmable smoke verification, Width 14.5" (36.8 cm) —.— pre -alarm delay, cross zoning and Depth: 3 -7/16" (8.73 cm) i — J enhanced verification mode features with 5/8" protruding that can help minimize false alarms Overall Dimensions: SK - 5208 • Programmable from the built -in Height 26 -3/8" (67 cm) control panel touchpad, remote Width. 17- 3/16" (43.66 cm) • SKSS Downloading Software annunciator, or Windows® SKSS Total Depth 4" (10.16 cm) • Plex -2 Door Option downloading software Operating Temp: 32° to 120° F Listings and Approvals • Direct connect port for on -site (0° to 49° C) • UL Listed up /downloading with Windows® Humidity 10 - 93% noncondensing . CSFM Listed SKSS downloading software • Built -in walk test feature Optional Accessories • MEA approval 429 -92 -E Vol. XIII • Single or dual interlock water • SK -5235 LCD Remote Annunciator releasing capability • SK -5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door with a clear • SK -5280 Status Display Module (8 window, limiting access to the panel max per system) while providing single button • 7181 Fire Zone Converter operation of the reset and silence • 5220 Direct Connect Module functions • 5824 Serval /Parallel Pnnter Interface • Programmable AC trouble relay Module v FIRE ALARM CONTROL PANEL Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled /disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 1� Direct Connect For On -Site Programming 2 Class A (Style D) II l'i' Ti or Class B (Style B) ► Programmable Initiation Circuits .11 Form C Relays 3 i 8 Class B (Style B) . !M:•' _► Notification Initiation Circuits •' (' .,_ x i• .. ... . :.. Appliance Circuits ■ _� ;_► r 5235 Remote Annunciators SBUS Devices • I - AI 5280, 5217, & 5824 To AC SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up-to -date and accurate We cannot cover KNIGHT all specific applications or anticipate all requirements All specifications are FORM# 350318 Rev C subject to change without notice For more information, contact Silent © 2010 Honeywell International Inc by Honeywell Knight 12 Clintonville Road, Northford, CT 06472 -1610 Phone (800) 328 -0103, Fax. (203) 484 -7118. www silentknight corn • V 22 I Photoelectric Smoke Detectors System Sensor 1 series smoke detectors represent significant advancement in conventional detection The i family is founded on three principles: installation TM ease, intelligence, and instant inspection. Features Installation ease. The 1 line redefines installation ease with its Plug-in detector line, mounting base included plug -in design This allows an installer to pre -wire bases (included • with heads) The large wire entry port and in -line terminals provide • Large wire entry port ample room for neatly routing the wiring inside the base The base • In -line terminals with SEMS screws accommodates a variety of back box mounting methods as well as • Mounts to octagonal and single -gang back boxes, 4- square back direct mounting with drywall anchors To complete the installation, 1 boxes, or direct to ceiling heads plug into the base with a simple Stop -Drop 'N Lock' action • Stop -Drop 'N Lock attachment to base Intelligence. 1 detectors offer a number of intelligent features • Removable detector cover and chamber to simplify testing and maintenance Drift compensation and Built-in remote maintenance signaling smoothing algorithms are standard with the 1 line to minimize nuisance alarms 2 -wire i detectors can generate a remote LED- - Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W -MOD2 • Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the 1 Wide angle, dual color LED indication protocol The SENS -RDR, a wireless device, displays the sensitivityof 1 detectors in terms of percent - per -foot obscuration • Loop testing via EZ Walk feature • Built -in test switch Instant inspection. The 1 series provides wide -angle red and green LED indicators for instant inspection of the detector's condition normal standby, out -of- sensitivity, alarm, or freeze trouble When connected to the 2W -MOD2 loop test /maintenance module or a panel with the 1 protocol, the EZ Walk loop test feature is available on 2 -wire 1 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector Agency Listings ® , MEA MSFM (ETL LISTED �FFFWEO I "1 approved approved 5911 30114:6 7272 - 1653152 290 01.1 2093 3160932 (j9 Smoke Detector Specifications '5i (.dillYa.1,o.1- Y 31,76))iY- 4ai1aff T frY liKl i}J .. >.. v. ..._ .. .. Smoke detector shall be a System Sensor P Series model number , listed to Underwriters Laboratories UL 268 for fire Protection Signaling Systems Tlie detector shall be a photoelectric type (Model 2W -B, 4W -B) or a combination photoelectric/thermal (Model 2WT -B, 4WT -B) with thermal sensor rated at 135°F (57 2 °C) The detector shall include a mounting base for mounting to 31/2-inch and 4 -inch octagonal, single -gang, and 4 -inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws The detector shall allow pre - wiring of the base and the head shall be a plug -in type The detector shall have a nominal sensitivity of 2.5 percent - per -foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual - color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT -B, 4WT -B) conditions. When used in conjunction with the 2W -MOD2 module, 2 -wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually (i k?C r. -lib :. , .. , . . Operating Voltage Nominal 12/24 V non - polarized Minimum. 8.5V Maximum 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2 -wire: 50 pA maximum average, 4-wire 50 pA maximum average Maximum Alarm Current 2 -wire: 130 mA limited by control panel; 4 -wire 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2-wire 100 pA; 4-wire n/a Alarm Contact Ratings 2 -wire. n /a, 4 -wire 05 A @ 30 V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter, 2.0 inches (51 mm) height Weight 63 oz (178 g) Operating Temperature Range 2W -B and 4W -B 32 °F to 120 °F (0 °C to 49 °C), 2WT-B and 4WT-B: 32°F to 100°F (0 °C to 37.8 °C) Operating Humidity Range 0 to 95% RH non - condensing Thermal Sensor 135°F (57 2°C) fixed Freeze Trouble 2WT -B and 4VVT -B only 411 (5°C) Sensitivity 2 5% /ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4 -inch octagonal back box Single -gang back box 4 -inch square back box with a plaster ring Direct mount to ceiling I :4?)lJ.teX%l ' 11- � Y "r!t: tiLK:ttJ.114 ''Ilil"S rt"4stiCs - Ti'. LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information y : 1 7,(ldl, !iiCtit.J: �!litari.,t• �, , 2W -B No 2 -wire 130 mA max. limited by control panel 2WT -B Yes 2 -wire 130 mA max. limited by control panel 4W -B No 4 -wire 20 mA @ 12 V, 23 niA @ 24 V 4WT -B Yes 4 -wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W -MOD2 2 -wire loop test / maintenance module RT Removal / replacement tool SENS -RDR Sensitivity reader A77 -AB2 Retrofit adapter bracket, 66 inch (16 76 cm) diameter k .:� ::' �~' :•-• -� � : ,..., -__ - j. l,! 32009 System Sell. 3825 Ohio Avenue • St Charles, IL 60174 Phone S00 SENSOR2 •Fax 530 377 -6495 Tm,ux,A , �ni;° .m: �; w° not, nu„ >rem encorn or curia t: Neu vermndrt°s data sRC, • r : .� M5-0318-00: S•'03 •210 • ` CONVENTIONAL FIRE CONTROL PANEL ACCESSORY _ PS -DA and PS -SA = ` i . ?" '. Conventional Pull- stations i� ''l � A F Easy to Install and Operate '9� w v:- .na . ' . 1:- LI s- ,•' ,, -- The PS- DA/PS -SA Pull Stations are non -coded manual pull stations which r provide a Fire Alarm Control Panel (FACP) with a single alarm initiating ___:_ - .1 °_ 1 ' -r ' input signal. The PS- DA/PS -SA pull stations includes both single- action and dual- action models equipped with key lock / reset. It was designed to meet multiple applications with the installer and end -user in mind. Its innovative design, durable construction, and mul- tiple mounting options make the PS -DA and PS -SA simple to install, maintain, and operate. Operation j The single- action pull- station is ' ' ' ! i L .- activated by a single pull -down of J -- . the alarm handle. The dual- action 4 -- - versions require pushing in the I handle, then pulling the handle ACTIVATED.: EM P 1�! ttaSH PUSH MI T «•� 1 " • '� EHACIAMAXI down for activation. pull PS- � (N PULL Down DA/PS-SA manual stations are PULL DOWN r , UL listed and meet the ADA �� •; requirement of a 5 -lbs. maximum " t °Ia'� pull force to activate. Operating instructions are molded into the - L r t t handle along with Braille text. r Molded terminal numbers can be . . ' . t ! found adjacent to the wiring termi- , ' .1 nals. — MIK Models: PS -DA PS -DASP PS -SA— Single action with 'pigtail' connections and a key lock reset. PS -DASP — Same as PS -DA Specification: Pigtail wires are provided for con- except with both English and Dimensions: nection to the Fire Alarm Control Spanish operating instructions. Height: 5 -1/2" (13.97 cm) Panel's (FACP) initiation circuit. Features: Width: 4" (10.16 cm) Depth: 1 -7/16" (3.65 cm) PS -DA — Dual action model with • UL Listed Operating screw terminal connections and a • CSFM Listed temperature. 32 °F to 120 °F key lock reset. (0 °C to 49 °C) • Meets ADA requirements PS -DAH — Same as PS -DA except Electrical. • Operating instructions are mold- Switch Contact with hex lock reset. ed into the handle along with Rating: 0 25 A @ 30 VAC PS -DALOB — Same as PS -DA with Braille text. or VDC "outdoor use" listing. Includes SB- • Made of durable Lexan Accessories: I/O backbox and sealing gasket. • Available in Spanish • SB -I /O Surface Mount 10 1/4 SII TIVT • Key resettable Back -box KNIGHT • Easy to Install and operate BG -TR Trim Ring • t y I iui,vj vae • li • Single or dual action • Surface mount box available ' 'CONVENTIONAL FIRE CONTROL PANEL ACCESSORY PS -DA and PS -SA Conventional Pull- Stations , „, ,.', , l `;�; ., Engineering Specification Manual Fire Alarm Stations shall be non -code, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching back -box SB -10; or semi -flush mounting on a standard single -gang, double -gang, or 4” (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national /local require- ments. Manual Stations shall be Underwriters Laboratories listed. *NOTE: The words "FIRE /FUEGO" on the PS -DASP shall appear on the front of the station in white letters, approximately 3/4" high. I I. -.. ___ f � l - 4 ti PULL I 1 .. s e ' � ■ _ al: I PS -SA Front View PS -DA Front View PS -SA Rear View PS -DA Rear View SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA it 4 NICHT keep our product information up- to-date and accurate. We cannot cover all NI , specific applications or anticipate all requirements. All specifications are sub- PIN 350241 Rev. C Jett to change without notice For more information, contact Silent Knight 12 © 2009 Honeywell International Inc r.v I In-iirye.: . Clintonville Road Northford, CT 06472 -1610 Phone: (800) 328 -0103, Fax (203) 484 -7118. www.silentknight com c ,t � ° FIRE SYSTEM ACCESSORY 5499 Distributed Power Module 4 4-.4 r.. The NAC expander that packs quite a combination punch, a whopping nine amps and built -in synchronization for appliances �r� R ;e' • The 5499 Distributed Power Module by Silent Knight is the most - powerful I f r v and cost - effective power supply available today. It delivers 9 amps of notification appliance circuit power and built -in synchronization for appliances from System Sensor®, AMSECO, Faraday, Gentex®, and Wheelock® — what you need to drive power -hungry components like ADA notification appliances. The 5499's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5499 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost - effective notification power supply available, you need the 5499. Call Silent Knight today for more information at 1- 800 - 446 -6444. Description • 2 inputs; 2 Class B (Style B) T w = The 5499 is a 9 amp notification power or 2 Class A (Style D) expander that provides its own AC •Ground fault detector /indicator power connection, battery charging • Independent trouble relay - circuit, and backup battery for use with • AC loss delay option shuts off power fire and security controls that have 9 -32 to non - essential high- current accessories like magnetic door VDC outputs, such as the Silent Knight holders � Model 5208 Fire Control /Communicator. • Stand alone operation. The 5499 is the cost - effective solution for powering notification appliances • Lightweight design adds to ease of installation and reduces shipping required by the Americans with costs Disabilities Act (ADA). The 5499 has • Operates with most polarized, UL built -in ANSI cadence pattern, which Listed notification devices can upgrade older control panels that • ANSI Cadence pattern output �" "" lack cadence capability. capability built -in 5499 Features Connection to Local Fire Control • UL Listed for 9 amps of notification Firepower 5499 may be connected to a 5499 to each notification circuit on the power local fire control which utilizes Class A control panel and still provide full • Built -in synchronization for appliances or Class B type notification circuits supervision of the notification circuits all from System Sensor®, AMSECO, operating between 9 and 32 VDC. The the way back to the control panel. Faraday, Gentex®, and Wheelock® control panel's notification circuit is • Power supply's advanced switch connected to one of the inputs on the mode design reduces damaging heat 5499. The control panel's notification and manages power up to 50% more p efficiently than other systems circuit end -of -line resistor is also • Dip switches allow for easy connected across two terminals on the reconfiguration Firepower 5499, which provides • 24 VDC filtered output voltage supervision between the 5499 and the • Four power - limited notification fire control panel. Polarized audible outputs; 2 Class A (Style Z) or 4 and /or visual notification devices are Class B (Style Y), then connected to the 5499 signal or 1 Class A and 2 Class B SILENT circuits using the 4.7kW end -of -line • Additional continuous auxiliary output resistors provided. Since the 5499 �.r KNIGHT • 3 amps per output circuit draws very little power from the control, :: ,.; it is possible to connect one Firepower by Her eyv.,e 1„,, 01;4E SY- M ACCESSORY 5499 Distributed Power Module Supervision Notification Circuits: 4 Aux Trouble: Yellow The 5499 supervises a variety of Output Configuration: Output functions including: 2 Class A (Style Z) troubles (1 -4): Yellow • Low AC power. 4 Class B (Style Y) (1 Class A & 2 Class B) Installation • Low battery condition. Surface mount • Earth ground fault. Amps Per Output: 3.0 (9.0 amps total) Notification Circuit Output: 20.4 to 27.3 Approvals • Auxiliary output power limit condition. NFPA 72 VDC @ 3.0 amps each, 4.7 k52 EOL • EOL supervision trouble or power resistor required on each Class B UL Listed limited condition at an output. circuit CSFM 7300 -0559: 123 When a trouble condition occurs, MEA 429 -92 -E Vol. XII Firepower 5499 creates a trouble No. of Inputs: 2 condition on the host control signal Input Configuration: 2 Class B (Style Y) Ordering Information circuits to which it is connected. or 2 Class A (Style Z) 5499 Firepower 5499 still maintains the Input Voltage Range: 9 - 32 VDC Distributed Power Module ability to be activated by the host Battery charging Capacity: 35.0 AH control. In addition, the 5499 provides a Form C trouble relay output as an Mechanical Specifications alternative to using the notification Dimensions: 12.25" W x 16" H x 3" D circuit trouble. 30.88 cm W x 40.64 cm H x 7.62 D cm Electrical Specifications Operating Temp: AC Input: 120 VAC at 3.0A 32° to 120° F (0° to 49° C) Output: 24 VDC at 9 A Humidity: 93% non - condensing max. Current Indicator Lights Standby: 75 mA AC power on Green Alarm: 205 mA Battery trouble: Yellow Auxiliary Power Circuit: 1 Ground fault: Yellow Model 5499 Block Diagram Signal Circuit Outp:;. . -_ s�pi??I t _ Signal 1 Inp61 /Distributed Signal Sign) Circuit Output - Signal 2 P o-ner Input Mod 5449 Signal lOp,rorrnl) Signal 4 120 VAC Aux. Power Traub :e Output Local Fire Control (Altemat.ve to notif_ ztion circuit traub;e.) SILENT This document is not intended to be used for installation purposes We try to MADE IN AMERICA KNIGHT keep de l specific our applications product information or anticipate up -to - all requirements ate and accurat All specifications We cannot cover are al FORM# 350396 Rev D 09/06 subject to change without notice. For more information, contact Silent Knight by I-lo.- royv..;! 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2006 Silent Knight Phone (800) 328 -0103, Fax: (763) 493 -6475 � S 77V k ): f r Selectable-Output - - 1 t, � � Horns, Strobes, and �,� R Horn Strobes . SpectrAlert° Advance selectable - output horns, strobes, ` `t and horn strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTR 'ert ra °° ., ... q . 7 sue a Features The SpectrAlert Advance series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy -to -use line of horns, strobes, and horn strobes in the industry With white and red plastic housings, wall and ceiling mounting • Tamper resistant construction options, and plain and FIRE - printed devices, SpectrAlert Advance can • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 meet virtually any application requirement candela • Field- selectable candela settings on wall and ceiling units 15, 15/75, Like the entire SpectrAlert Advance product line, horns, strobes, 30, 75, 95, 110, 115, 135, 150, 177, and 185 and horn strobes include a variety of features that increase their • Horn rated at 88+ d3A at 16 volts application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back • Rotary switch for horn tone and three volume selections box, which make installations fast and foolproof while virtually • Universal mounting plate for wall and ceiling units eliminating costly and time - consuming ground faults. Furthermore, • Mounting plate shorting spring checks wiring continuity before a universal mounting plate with an onboard shorting spring tests device installation wiring continuity before the device is installed, protecting devices • Electrically compatible with existing SpectrAlert products from damage Compatible with MDL sync module In addition, field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements Agency Listings SIGNALING (0) • "O� ® MEA roved 7175- I653186(:ndoor,,obn) LISTED APPROVED approved 7175 - 1653185 shorn s ;robes. 5+011 (chunes. nan rrobes horns] 3073577 MEMSS.OS E ch,me ancbes) 55512 (strobes) 713 -1653 183 (bans, c- mes) • • SpectrAlert Advance Specifications Architect/En. sneer S • ecifications ; General SpectrAlert horns, strobes,:and horn strobes shall mount to a standard 4 x 4 x inch back box, back box,:or double •gang back '- " -- - - box.Two-wire products shall also mount to a single -gang 2 x 4 x 1' /a -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate Also, SpectrAlert Advance products, when used with the Sync - Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts When used with the Sync-Circuit Module, 12- volt -rated notification appliance circuit outputs shall operate between 9 and 17 5 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15, 15/75, 30, 75, 95, 110, 1 15, 135, 150, 177, and 185 Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range The strobe light shall consist of a xenon flash tube and associated lens/reflector system Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service The horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range The strobe light shall consist of a xenon flash tube and associated lens/reflector system The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered Independently of the sounder.The horn on horn strobe models shall operate on a coded or non -coded power supply Synchronization Module The module shall be a System Sensor Sync - Circuit model MDL listed to UL 464 and shall be approved for fire protective service The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires The module shall mount to a 4 ° /,e x 4 ° /,b x 21/4-inch back box The module shall also control two StyleY (class B) circuits or one Style Z (class A) circuit The module shall synchronize multiple zones Daisy chaining two or more synchronization modules together will synchronize all the zones they control The module shall not operate on a coded power supply Ph seal /Electrical S S. eafications Standard Operating Temperature 32 °F to 120 °F (0 °C to 49 °C) Humidity Range 10 to 93% non - condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range' 8 to 17.5 V (12V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 68" diameter x 2.5' high (173 mm diameter x 64 rnm high) Wall -Mount Dimensions (including lens) 56'L x 4 7 x 2 5 mm Lx 119 rnm W x 64 mm D) Horn Dimensions 56 4:7 "W x 13 mm L x 119 mm W x 33 mm D) Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW -2) 5 9 "1 x 5.0 - W x 2.2 - D (151 rnrn L x 128 nun W x 56 mm D) Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7 I diameter x 2.2 - high (180 mm diameter x 57 rnrn high) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR -HS, TRW -HS) 5 T L x 4 8 W x 035 mm L x 122 rnm W x 9 mm D) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC -HS, TRCW -HS) 6 9" diameter x 0.35 high (175 mm diameter x 9 mm high) Notes: 1 Full Wave Rectified (FWR) voltage is a non- regulated, time - varying power source that is used on some power supply and panel outputs 2 e S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd .35-039Sm? - . UL Current Draw Data lJl. Max Strobe Current D • , rawd WS)- - , I UL Max. Horn Current Draw m , ,. 8 -17.5 Volts 16-33 Volts 8 -17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non - temporal High 57 56 69 75 95 NA NA 181 176 Non- temporal Medium 42 50 60 69 110 NA NA 202 195 Non- temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range ISO NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 1 Draw (mA RNIS), &MAUD Strobe, Standard Candela 3(15 -115 cd) , 8 -17.5 Volts 16 -33 Volts DClnput 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non - Temporal Medium 133 145 75 85 102 163 187 207 216 Non - Temporal Low 131 144 68 79 96 156 182' 201 210 • FWR Input Temporal High 136 155 88 97 112 168 190 210 218 temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non - Temporal High 142 161 103 112 126 181 203 221 229 ' Non - Temporal Medium 134 155 85 95 110 166 189 208 216 Non Temporal Low 132 154 80 90 105 161 184 202 211 I D : 1 1 3 , Draw (mAGUNIMUDILIRStrobe, Hi . h Candela p Q l I 16-33 Volts 16 -33 Volts DClnput 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non- Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non - Temporal Medium 2.42 259 2.93 299 Non- Temporal Medium 2.19 232 262 267 Non Temporal Low 238 254 291 295 Non - Temporal Low 214 229 256 262 Horn Tones and Sound Output Data IitimaLJE D out.utQ I 8 -17.5 16 -33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non - Temporal High 82 82 88 88 93 92 100 100 S Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non - Temporal Low 75 75 81 81 88 84 96 92 7 Coded High 82 82 88 88 93 92 101 101 ' 8' Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2 -wire horn strobe MS -0395-0W • SpectrAlert Advance Dimensions • 4.7" + 2.5' 8' Dia. piiMnip i � l . . • - 2s• . e 1 .‘ Wall -mount horn strobes Ceiling -mount horn strobes r -2 25'+1 x 2.23+1 I II O o Q � rope. O 5.98 o t o e c • 'O Wall back box skirt Ceiling back box skirt • SpectrAlert Advance Ordering Information I Descri • ion I I . Description Wall Horn Strobes Ceiling Strobes P2R" 2 -Wire Horn Strobe, Standard cd Red SCR Strobe, Standard cd, Red P2RH" 2 -Wire Horn Strobe, High cd, Red SCRIM Strobe, High cd, Red P2W' 2 -Wire Horn Strobe, Standard cd,White SCW" Strobe, Standard cd, White P2WH" 7 -Wire Horn Strobe, High cd,White SCWH Strobe, High cd, White P4R" 4 -Wire Horn Strobe, Standard cd, Red Horns • P4RH 4 -Wire Horn Strobe, High cd. Red HR Horn, Red P4W 4 -Wire Horn Strobe, Standard cd, White HW Horn, White Wall Strobes Accessories • SR *t Strobe, Standard cd, Red BBS -2 Back Box Skirt, Wall, Red SRH•' Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White SW' Strobe, Standard cd, White BBSC -2 Back Box Skirt, Ceiling, Red SWH' Strobe, High cd, White BBSCW -2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes TR -HS Trim Ring, Wall, Red PC2R" 2 -Wire Horn Strobe, Standard cd, Red TRW -HS Trim Ring, Wall White PC2RH 2 -Wire Horn Strobe, High cd, Red TRC -HS Trim Ring, Ceiling, Red PC2W ' 2 -Wire Horn Strobe, Standard cd, White TRCW -HS Trim Ring, Ceiling, White PC2WH' 2 -Wire Horn Strobe, High cd, White PC4R 4 -Wire Horn Strobe, Standard cd, Red PC4RI-I 4 -Wire Horn Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White Notes: • Add - -P'to model number for plain housing (no'FIRE•marking on cover), eg, P2R -P t Add' -SP' to model number for 'FUEGO' marking on cover, eg, P2R -SP ;'Standard cd'refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 candela settings 'High cd' refers to strobes that include 135, 150, 177, and 185 candela settings 6Th SYSTEM 02(09 Symms Sense.. [ Y/ rd/ LL s SUVVLL// 33250h�oAvenue•St Charle5,IL60174 Prod unrpecnrauon: wMKs�ochrge unnosono.ceUm:rycenensoeca-�sa 4 SENSOR' Phone 800- SENSOR2 • Fax 630 - 377 -6495 wrens product u2m-ur.on mind g rhe larev•rvon d^ns data shee•, n05 -0395007 a -09..3132 ,i j oil 774 ,,,:,,, N .... _ 2012 9 • CITY' N i3UILIG `i C y!VESLC:YJ I 6 . NAC ZONE 3 JANITOR CLOSET WF ZONE 1 w OF FACP �u 110 TAMPER ZONE 2 RISER o ES S ROOM LEGEND U) D < �+ ROOM v _ v, o , a � , _ �� D_ E 7 0 — NAC i s� Z/ - Z /9 u z pg zpn vw Z /yl _ t /� / I FRCP Q = a rn \ HORN S TROBE - - SYSTEM SENSOR P2R 1- a t / try` / ` 'u ° RK ROOM • ZONE 4 80" BOTTOM OF DEVICE TO F.F. a °cn ° Z /N NA TUR AL Z /�l{ //ti ' ©1 5 1/ F O O O ci <,... 110 ® A 110 110 ` © STROBE - - SYSTEM SENSOR S2R a w `ri tom 10 \ HALLWAY ,Q O 80" BOTTOM OF DEVICE TO F.F a o_ o_ � - PRE -SALES .v. RETAIL v mg R ESiR00M r �' ` D PULL STATION -- SILENT KNIGHT SD500-PS 18/4 T FACP 18/4 18/4 42" - 48" BOTTOM OF DEVICE TO F.F. WDMENS RES1ROOM T FACP T FACP R ' '�. is 0 ADDRESSABLE SMOKE DETECTOR -- SILENT KNIGHT SDI o N ZONE 5 ZONE 6 ZONE 7 °o ' 0 DUCT SMOKE DETECTOR -- INSTALLED BY OTHERS AQUARIUM N V ;REAM ROOM Y A ® 4 S 5 IFA.CP FIRE PANEL -- SILENT KNIGHT 5208 • W ,"- o ;< E ZON 0 L. 2 l •� 1UB ROOM NAC STROBE PANEL -- S /LENT KNIGHT 5499 1-. w o 110 / 1/ S & ir e Hra (fl co 110 110 E / ` J - 1 U N a AD0P70N � E.O.L. = END Of LINE ' °' 1a' -a. E � 1 : 0 m in z "(7, N ZONE 1 ® O I _ � ©1 S 15 14/2 = 14/2 CABLE Z a L,_,,, J r 5' -5 1/2 \ J �, / RECEP11ON I r OFRc VESneuLE ' ® 78/4 = 18/4 CABLE z (I)._ . 1 I 1 0 0 0 Z o GROOMING 0 U Q L� 14 .�— . _ 1 .5' n SALON Z D Q al CO ' - 0" ® f N ~3 NC ZED 0(G) O 0 OU o w > N HI rn cr ,2 _1 1 Z o N N U .k18(2) ((O� U I- i-`4* M M PROJECT # 11106 DATE: USE 05 -30 -12 SUBM ITTALS SHEET TITLE FIRE ALARM SYSTEM scALE. 1/16" = 1' - 0 " DESIGNED Br LARRY DRAWN BY: BRYAN S E 1 of 1 ALARM I SCALE 1/16 " =1' -0" i T JOB # DW10 -030