Loading...
Plans[Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] FPS Zoio- 000 5 10 30 o 51nI 11 5 t24 Simplex TrueA /ert Multi - Candela Notification Appliances Z UL, ULC, CSFM Listed; FM Approved; SmartSyncTM Operation AudibleNisible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non - Addressable Features -- Audible /visible (NV) notification appliances with efficient electronic horn and high output xenon -- • strobe, available for wall or ceiling mount • Operation is compatible with ADA requirements (refer to important installation information on page 3) ). •; i r • • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens E Operates over a two -wire SmartSync circuit to provide: • Horns that are controlled separately from strobes on the ) t same two -wire circuit _ • "On- until - silenced" and "on- until - reset" operation on — the same two -wire pair • SmartSync horn activation of Temporal pattern, March FORE Time pattern (at 60 BPM), or on continuously • Strobe appliances on the same circuit operating at a 1 � y 1 synchronized 1 Hz flash rate ■ • Class B (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905 -9938 Wall and Ceiling Mount A/Vs • Class A (Style Z) operation when connected to the Descri s tion 4905 -9938 SCM or with 4100U series fire alarm control panel NACs Multi Candela TrueAlert A/Vs with horn and synchronized strobe provide convenient installation Wall mount ANs features: to standard electrical boxes. The enclosure designs are • Wiring terminals are accessible from the front of the both impact and vandal resistant and provide a convenient housing providing easy access for installation, strobe intensity selection. Since each model can be inspection, and testing selected for strobe intensity output, on -site model • Covers are available separately to convert housing color inventory is minimized and changes encountered during • Available UL listed sound damper for locations construction can be easily accommodated. requiring attenuation of 5 to 6 dBA (stairwells, small Wall mount AN housings are a one -piece assembly rooms, highly reverberant areas, etc.) (including lens) that mounts to a single or double gang, or Optional adapters and wire guards: 4" square standard electrical box. The cover can be • Wall mount AN adapters are available to cover surface quickly removed (a tool is required) and covers are mounted electrical boxes and to adapt to Simplex available separately for color conversion. 2975 -9145 boxes Ceiling mount ANs install using standard 4" electrical • UL listed red wire guards are available for wall or boxes. Color choice is determined by model number. ceiling mount A/Vs Visible notification appliance (strobe): Strobe Intensity Selection • 24 VDC xenon strobe; intensity is selectable as 15, 30, During installation, a selection plug at the back of the 75, or 110 candela with visible selection jumper secured housing determines the desired strobe intensity. An behind strobe housing attached flag with black letters on a highly visible yellow • UL listed to Standard 1971 background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current • This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing Audible notification appliance (horn): 7125 - 0026:317 for allowable values and /or conditions concerning material presented in this document. It is subject to re- examination, revision, and possible cancellation. Accepted for • Low current, 24 VDC electronic horn with harmonically use - City of New York Department of Buildings - MEA35 -93E. Refer to page 2 for listing rich sound output suitable for either steady or coded status of wire guards. Additional listings may be applicable; contact your local Simplex operation (Temporal or 60 BPM March Time pattern) product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. • UL listed to Standard 464 " Simplex multi - candela SmartSync two -wire hom /strobe appliance operation is protected under one or mom of the following U.S. Patent Numbers: 5,559,492; 5,622,427; 5,865,527; 5,886,620; 6,281,789; 6,954,137; 7,005,971; and 7,006,003. S4906- 0002 -4 12/2007 Strobe Application Selection Smart Sync Two -Wire Control Proper selection of visible notification is dependent on Smart Sync operation mode allows a two -wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of: the National Fire Alarm Code (NFPA 72), ANSI the same NAC and then allow the horn to be silenced A117.1; the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO, or SBCCI; and the application guidelines of the "on- until - silenced" while the strobe operation is Americans with Disabilities Act (ADA). "on-until-reset." Synchronized Strobes SmartSync Control Sources Multiple Strobes. When multiple strobes and their • 4006, 4008, 4100U, and 4010 Fire Alarm Control reflections can be seen from one location, synchronized Panels (refer to individual product data sheets for more flashes reduce the probability of photo-sensitive reactions information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender (refer to data sheet random flashing. The multi - candela strobes of these ANs S4009-0002) are synchronized by the controlling SmartSync operation • SmartSync Control Module (SCM) 4905 -9938 (refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination Product Selection horn/strobe notification appliances. Multi- Candela ANs Model Mounting Housing Color "FIRE" Lettering Description 4906 -9127 Wall Red White 4906 -9129 White Red Horn with Multi - Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two -wire 4906 -9128 Red White control Ceiling 4906 -9130 White Red Wall Mount A/V Accessories Model Description Dimensions 4905 -9937 Red Surface Mount Adapter Skirt; use to cover 1 -1/2" (38 mm) deep 5 -3/8" H x 5 -1/4" W x 1 -5/8" D 4905 -9940 White surface mounted boxes (136 mm x 133 mm x 41 mm) depth with strobe = 4-3/8" (111 mm) 4905 9931 Red Adapter Plate for mounting to Simplex 2975 -9145 box (typically for 8 -5/16" x 5 -3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red Mounting Box, requires Adapter Plate 4905 -9931 7 -7/8" x 5-1/8" x 2-3/4" D • (200 mm x 130 mm x 70 mm) Optional Sound Damper; package of 20; field installed adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA 1 -3/4" Diameter (44.5 mm) NOTE: After Sound Damper installation, measure sound level to ensure with 0.31" (8 mm) sound opening compliance with applicable code requirements SmartSync Control Module Model Description Dimensions 4905 9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4 -1/8" x 1 -1/4" D (102 mm) square box; refer to data sheet S4905 -0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description • Dimensions 4905 -9994 Red cover with white "FIRE" lettering 5 -1/8" H x 5" W x 1 -1/2" D 4905 -9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description . Dimensions 4905 9961` Wall mount red wire guard with mounting plate, compatible with semi -flush 6 -1/16" H x 6 -1/16" W x 3 -1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905 -9927` Red Wire Guard for mounting to flush mounted electrical box 8-1/2" x 6-1/8" x 3" (216 mm x 156 mm x 76 mm) 4905-9928* Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905 -9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4" x 6 -7/8" x 1 -1/2" deep, 4905 -9916 Red 1 -1/2" deep surface mounted boxes (121 mm x 175 mm x 38 mm) • UL listed by Space Age Electronics Inc. 2 S4906- 0002 -4 12/2007 A/V S•ecifications •• Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 DC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526 -M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93 %, non - condensing at 100° F (38° C) Connections • Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate • Horn Output Voltage 16 VDC 24 VDC .33 VDC Ratings Sound Type (see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft (3 m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note 2) Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5 -1/8" H x 5" W x 2 -3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting (see Note 3 below) 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC 67 mA 103 mA 196 mA .253 mA at other voltages 24 VDC 50 mA 77 mA 147 mA ' 190 mA Housing Dimensions (with lens) 4 -3/4 L" x 6 -7/8" W x 2 -5/8" D (121 mm x 175 mm x 67 mm) Ceiling Maximum RMS Current Rating per • 15 cd 30 cd 75 cd. 110 cd Mount Strobe Setting (see Note 3 below) 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC 76 mA 117 mA • 222 mA 284 mA at other voltages 24 VDC 57 mA 88 mA 167 mA 213 mA . NOTES: 1. "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded hom output "peak" sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. 3. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi -Flush Mounting Mounting is compatible with O ' o single gang, double gang, and 4" (102 mm) square boxes, 1 ° 1 I IMPORTANT! WALL MOUNT 1 -112" (38 mm) deep, by others �� �►� p���� BNSTALLATION HEIGHT REFERENCE 38 C ❑ - Sound Damper, Optional field 4905 attached Ii�al I • Bottom of lens to attenuate sound 5 to 6 dBA I� is either even ....m..m. / I with, or slightly Electrical or p✓0�t _ • I ! above bottom box outline Wiring access hole — 0 - 01 • =- % of compatible �I( :,:' >.: boxes Wiring terminals for • I p \� 5 V � i_ II 1 7 SmartSync operation I I1 Mounting Holes: 1 4" square (4) NFPA 72 requires 80" (2.03 m) ..•.... ammom ,' -G. : II� that the entire lens minimum t7 S ingle gang (2) sill I be not less than Double gang (3) ���i 80" and not greater : � than 96" above the Transparent housing finished floor and lens assembly Intensity selection plug, accessible only ® from near of housing; ir, { [1 factory setting is 15 cd i Removable cover Strobe intensity (tool required) viewing slot 3 S4906- 0002 -4 12/2007 Ceiling Mount A/V and Guard Installation Reference Ceiling reference, 4" (102 mm) square box, Optional 4905 -9928 Adapter Plate, surface mounted box 1 -1/2" (38 mm) minimum depth required for surface mounted electrical box 1 11 I Mall all I Four mounting clamps included, two each side . I1�1F1TR ill I I C Ceilin I/ 4 , flush mounted referencebox , ' $ 1I I I��� r� I Optional 4905 - 9915/ -9916 Adapter, l recommended for surface mounted box Wiring terminals are Optional 4905 -9927 / Red Wire Guard , i located behind the housing 0 — g R E End View I • Strobe intensity viewing slot " . I ^C- Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference /2975 9145 Box with Optional Adapter Skirt o and Optional Wire Guard n Surface mount conduit and O MI box shown for reference 4" (102 mm) square ° [ Url i °�� e"f' ' box profile, 1 -1/2 I , 11111 0 II (38 mm) deep all= f 1 -T _ Optional F -� ' 0 O 4905 -9961 a II' I Wire Guard _ 0 AN , r l� ,; FORE L 0 • _ -� / 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O �� 4905 -9961 Optional Wire Guard 1 -1/2" deep: 4905 -9937, Red; (shown here for reference only, 4905 -9940, White (conduit knockouts 4905 -9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco is a registered trademark of Tyco International Services GMBH and is used under license. Simplex. the Simplex logo, IDNet, TnteAlert, and SmartStnc are trademarks of Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association (NFPA). f3 Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4906 0002 - 12/2007 ® www .tycosafetyproducts- usa- wm.com 0 2007 Tyco Safety Products Westminster. All rights reserved. All specifications and other infotmation showtn were current as of document revision daze and are subject to change without notice. Ei Simplex TrueA /ert Multi - Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non - Addressable, SmartSyncT'" Operation Compatible Features - Visible only (V /O) 24 VDC notification appliances with high output xenon strobe, available for wall • or ceiling mount: , • UL listed to Standard 1971 • Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing • Operation is compatible with ADA requirements (refer n to important installation information on page 3) • Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Wall Mount Strobes • Regulated circuit design ensures consistent flash output and provides controlled inrush current I E [R E • Rugged, high impact, flame retardant thermoplastic ti — I housings are available in red or white with clear lens 1 �+ } jY � •:� ! I ; l' j % Strobes provide synchronized flash for use with: • 4006, 4008, 4010, and 4100U Series fire alarm control Ceiling Mount Strobes panels with NACs selected to provide strobe synchronization or SmartSync two -wire control** Descri •tion • 4009 IDNetTM NAC Extenders Multi - Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules (SCMs) that resistant and provide a convenient strobe intensity provide Class B or Class A output from conventional selection. Since each model can be selected for intensity NAC inputs output, on -site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy, and accommodated. convenient semi -flush or surface wall mounting: Wall mount strobe housings are a one assembly • Rear of housing does not extend into box (including lens) that mounts to a single or double gang, or • Wall mount strobes easily mount to single gang, double 4" square standard electrical box. The cover can be gang, or 4 -inch square outlet box quickly removed (a tool is required) and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection, and testing Strobe Intensity Selection • Covers are available separately to convert housing color During installation, a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex 2975-9145 boxes Strobe Application Reference • UL listed red wire guards are available for wall or ceiling mount strobes Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI • This product has been approved by the California State Fire Marshal (CSFM) pursuant to A117.1; the appropriate model building code: BOCA, Section 13144.1 of the California Health and Safety Code. See CSFM Listing pp 7125. 0026:316 for allowable values and/or conditions concerning material presented in ICBO , o r SBCCI; and the application guidelines of the this document. It is subject to re-examination, revision, and possible cancellation. Refer to Americans with Disabilities Act (ADA). page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex •• Simplex multi- candela SmartSync two-wire horn/strobe appliance operation is protected Time Recorder Co. are the property of Tyco Safety Products Westminster. under one or more of the following U.S. Patent Numbers: 5,559,492; 5,622,427; 5,865,527; 5,886,620; 6,281,789; 6,954,137; 7,005,971; and 7,006,003. S4906- 0001 -3 5/2008 Synchronized Strobes Smart Sync Control Sources Multiple Strobes. When multiple strobes and their Class B Smart Sync two -wire control is available reflections can be seen from one location, synchronized from: flashes reduce the probability of photo- sensitive reactions • 4006, 4008, 4100U, and 4010 Fire Alarm Control as well as the annoyance and possible distraction of Panels (refer to individual product data sheets for more random flashing. These multi - candela strobes are information) • synchronized over a two -wire circuit when connected to compatible NACs, to compatible Synchronized Flash • 4009 IDNet NAC Extender (refer to data sheet Modules, or to Smart Sync Control Modules. S4009 -0002) • Smart Sync Control Module (SCM) 4905 -9938 (refer to Smart Sync Two -Wire Control data sheet S4905 -0003) Some applications desire the audible notification Class A Smart Sync two -wire control is available appliances to be capable of being silenced before the from 4100U NACs and from the 4905 -9938 SCM. alarm condition is reset (on- until- silenced) while the Additional Smart Sync compatible notification visible notification appliances are kept activated until the appliances include separate horns and combination alarm condition is reset (on- until - reset). Smart Sync horn/strobe notification appliances. operation mode provides this function using a single circuit (two -wire operation). Product Selection Multi - Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color "FIRE" Lettering Description 4906 -9101 Wall Red White 4906 -9103 White Red Multi- candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9102 Ceiling Red White Smart Sync two -wire control compatible 4906 -9104 9 White Red Wall Mount Strobe Adapters Model Description Dimensions 4905 -9937 Red Surface Mount Adapter Skirt; use to cover 1 -1/2" (38 mm) 5 -3/8" H x 5-1/4" W x 1 -5/8" D deep surface mounted boxes (136 mm x 133 mm x 41 mm) 4905 -9940 White Total depth with strobe = 4-3/8" (111 mm) 4905 -9931 Red Adapter Plate for mounting to Simplex 2975 -9145 box (typically for 8 -5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red Mounting Box, requires Adapter Plate 4905 -9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905 -9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905 -9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905 -0003 for additional information) Model Description Dimensions 4905 -9914 Class B Synchronized Flash Module; epoxy encapsulated with 1 -3/8" x 2- 7/16" x 13/16" in /out 18 AWG (0.82 mm) wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905 -9922 Class A requires 10 mA for power 4905 9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4 -1/8" x 1 -1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905 -9992 Red cover with white "FIRE" lettering 5 -1/8" H x 5" W x 1 -1/2" D For Wall mount strobes 4905 -9993 White cover with red "FIRE" lettering ( 130 mm x 127 mm x 38 mm) 4905-9961* Wall mount 6- 1/16" H x 6 -1/16" W x 3 -1/8" D Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) semi -flush or surface mounted boxes 6 -1/8" x 4 -3/8" x 2 -7/8" deep 4905 -9926" Ceiling mount (156mmx111 mmx73mm) • UL listed by Space Age Electronics Inc. 2 S4906-0001 -3 5/2008 Strobe S•ecifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526 -M878 Flash Rate 1 Hz • Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93 %, non - condensing at 100° F (38° C) • Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm two wires per terminal for in /out wiring Housing Dimensions (with lens) 5 -1/8" H x 5" W x 2 -3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Strobe Setting (see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 224 mA at other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4-3/4" L x 2 -5/16" W x 2 -5/8" D (121 mm x 75 mm x 67 mm) Ceiling Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Strobe Settin g (see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RMS Currents 18 VDC 67 mA 111 mA 207 mA 281 mA at other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi -Flush Wall Mounting Mounting is compatible with 1 ( 0 0 � \ o ( \ single gang, double gang, and I 1 4" (102 mm) square boxes, 1 -1/2" (38 mm) deep, by others X01 _ I a n _ i I,1I!1 i •i _ IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE. Bottom of lens VIWIr Q i either even with, or slightly r Electrical Wiring access hole i . I - above bottom box outline g: - ® ON, of compatible 1 i _ II L� boxes + Wiring terminals /�I�! , �, t — r \ \ .-41 Mounting Holes: 7 • II 4" square (4) NFPA 72 requires 80" (2.03 m) Single gang (2) that the entire lens minimum w ���� " � Double gang (3) be not less than 1 �IP P 80" and not greater so than 96" above the Transparent housing finished floor and lens assembly Intensity selection plug, accessible only A i . from rear of housing; F [1 n E factory setting is 15 cd al - Removable cover Strobe intensity (tool required) viewing slot 3 S4906- 0001 -3 5/2008 • Ceiling Mount Strobe Installation Reference • • • Handy box, 1 -1/2" ( 38 mm) deep • • • Single gang box (Wiremold (RACO 650 or equal) or single gang V5744S) 2 1/4" (57 mm) box, 2 -1/2" (64 mm) deep (RACO 519 deep, supplied by others or equal) supplied by others . Also can be attached to boxes - ' /r 4 mounted to drop ceiling T -bar with • clips (ERICO No. 512 or equal) • U U U 4905 -9910 Adapter Plate, required for surface mount with handy box unless o . using the 4905 -9926 wire guard . I • • 1 °I • Ceiling mount strobe. 11 V'I'II Fl I] I O IE P Optional 4905 -9926 wire guard i ir-. 0 �l ,l with mounting plate I te ! , Strobe intensity • /. Ve ∎ ■■ ' ty p viewing slot © Intens selection le g, , 1 g accessible only from rear of lens i housing; factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate,_ Guard,_ and Adapter Skirt . • Surface Mounting Reference . 2975 - 9 1 45 Box with Optional Adapter Skirt and Optional Wire Guard - M — n Surface mount conduit and 0 1 box shown for reference i —� �—� 4" (102 mm) square �Ir 1711 == =1 :4l t �+ p box rofile, 1 -1/2" I I (38 mm) deep _ IN Me 174 = I _ I o o I al .Option 4905-9961 Option 111 • i I Wire Guard It Strobe A mi rL • L II� =� I, 4905 -9931 Adapter Plate l I I ■ _ i Optional Surface Mount Adapter Skirt, ' O 4905 -9961 Optional Wire Guard 1 -1/2" deep: 4905 -9937, Red; (shown here for reference only, 4905 -9940, White (conduit knockouts 4905 -9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco is a registered trademark of Tyco International Services GMBH and is used under license. Simpler, the Simplex logo, IDNet, Tr ueAlert, and SmartSvnc are trademarks of Tyco International Ltd. and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). B Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4906- 0001 -3 5/2008 m www.tycosafetyproducts usa- wm.com c 2008 Tyco Safery Products Westminster. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.