Specifications 1 1-909 5v‘/ (o Pkwy ,5o Fi°52OCci 0049 S DELT 14795 S.W. 72 Avenue PORTLAND, OR 97224 RECEIVED FIRE, INC. PHONE 503 - 620 -4020 FAX 503 - 620 -1058 CCB# 64174 OCT 1 4 2009 CITY OF TIGARD BUILDING DIVISION Pacific Parkway Center S cheller Financial DATA SUBMITTAL FOR FIRE PROTECTION SYSTEM October 13, 2009 09 -4388 FIRE PROTECTION CONTRACTORS Pacific Parkway Center — Scheller Financial October 13, 2009 Page 2 of 2 TABLE OF CONTENTS Pipe & Fittings Pipe CIS Fittings Victaulic Mechanical Tee Fig. #920/921 Hangers Tolco Pipe Ring Fig. #200 Tolco Top Beam C lamp Fig. #65 Tolco Retainer Strap fig. #69 Hilti Drop in Anchor Fig. #HDI -P Sprinkler Heads Reliable Model FIFR1/2" 155 Degree Pendent FIRE PROTECTION CONTRACTORS • ! - =7 - - - Pipe and Supply Corp. Pipe Specification A135 S •ecification A135 NPS 1/4 -- 30 ", Schedules 10, 40 and XL THD, Liqhtwall Scope Covers two grades of electric resistance welded steel pipe. Grade A is adapted for flanging and bending and is suitable for welding. Purpose for which pipe is intended should be stated on order. Kinds of Steel Permitted Open -hearth Basic- oxygen For Pipe Material Electric - furnace Permissible Variations The minimum wall thickness at any point shall not be more than 12.5% under the nominal wall thickness specified. in Wall Thickness Threadable, lightwall (XL) must meet manufacturers minimums. Chemical C max % Mn max % P max % S max Requirements Seamless or ERW Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Tensile Grade A Grade B Requirements Tensile Strength, min., psi 48,000 60,000 Yield Strength, min., psi 30,000 35,000 NDE & Hydrostatic inspection test pressures for plain end and threaded are specified. Hydrostatic pressure shall be maintained Hydrostatic for not less than 5 seconds for all sizes of electric resistance weld pipe. Non - destructive electric test should be in accordance Testing with practices E213, method E227 or practice E213. Permissible Variations Plus or Minus 10% schedule 10 in Weights per Foot Plus 10% minus 3 1/2% schedule 40 Permissible Variations Plus or minus 1% in Outside Diameter Mechanical Tests Tensile Test -- Transverse returned on pipe NPS 8 and larger. Specified Flattening test -- Three steps required with weld located 0° or 90° from the line of direction of force required. Number of Flattening and tensile on one length of pipe from each lot of 400 lengths or less of a style. Tests Required Lengths Pipe shall be furnished in 38' with a minimum of 20 ft. Pipe furnished to schedule 10 shall be in a specified length between 16 and 22 ft. Required Markings Rolled, Stamped or Stenciled (Mfgrs. Option) on Each Length Name or brand of manufacturer. (On Tags attached to Kind of pipe, that is, electric- resistance welded A, electric welded B, same schedule wall thickness, schedule 10 or 40, NL each Bundle in case ASTM A135 of Bundled Pipe) Length of pipe. General End finish may be plain end beveled or plain end square cut. Information Standards and Specifications CO 1L uiE ■w wTtOwwE, Iwc. !AI Dimensions Material Galvanizing Thread Pressure Rating Federal/Other M.I. Fittings 1 Class 150 /PN 20 ASME 816.3• ASTM A -197 ASTM A -153 ASME 81 20.1+ ASME 816.3• ASME 816.3" Class 300 /PN 50 ASME 816.3• ASTM A -197 ASTM A -153 ASME 8120.1+ ASME 816.3• f M.I. Unions Class 1 50/PN 20 ASME 816.39• ASTM A -197 ASTM A -153 ASME 8120.1+ ASME 816.39• ASME 816.39 - Class 250 ASME 816.39• ASTM A -197 ASTM A -153 ASME 8120.1 « ASME 816.39 - Class 300 /PN 50 ASME 816.39• ASTM A -197 ASTM A -153 ASME 8120.1+ ASME 816.39• Cast Iron Threaded Fittings Class 125 ASME 816.4• ASTM A -126 (A) ASTM A -153 ASME 31,20.1. ASME 816.4• ASME 816.48 Class 250 ASME 816.4• ASTM A -126 (A) ASTM A -153 ASME 81.20.1+ ASME 816.4- ASME 816.4• C. 1. Plugs and Bushings ASME 816.14• ASTM A- 126 (A) ASTM A -153 l ASME 81.20.1+ ASME 816.14• WW -P -471 C. 1. Drainage Threaded Fittings ASME 816.12• ASTM A -126 (A) ASTM A -153 ASME B1.20.1« ASME 816.12• 4 C. 1. Flanges and Flanged Fittings Class 125 (1' -12') ASME 816.1• ASTM A -126 (A) or (B) ASTM A -153 ASME 81.20.1+ ASME 816.1 ASME 816.1• Class 125 (14'-up) ASME 816.1• ASTM A -126 (8) ASTM A -153 ASME 81 .20.1+ ASME 816.1 ASME 816.1• Class 250 (11%121 ASME 816.1• ASTM A- 126 (A) or (8) ASTM A -153 ASME 8120.1. ^ ASME 816.1 _ ASME 816.1• Class 250 (14' -up) ASME 816.1• ASTM A -126 (8) ASTM A -153 ASME 81.20.1. ASME 816.1 ASME 816.1• Forged Steel Threaded Fittings Class 2000. 3000. ASTM A1 6000 ASME B1611• ASTM A18282 , ASME81.20.t« ASME 316 11. ASTM A350 _ Pipe Nipples Steel Pipe ASTM A733 ASTM ASME 81.201. WWN 351 - Welded Type F or Type E Steel Pipe - Seamless ASTM A733 ASTM A106 Gr. 8 ASME 81.20.1+ WWN 351 (High Temp.) Brass ASTM 843 ASME 81.20.1+ I WWN 351 The standard •an American National standard (ANSI) +ASME 81.20.1 was ANSI 82.1 •Formerly WW -P -501 •'Formerly WW -P -521 • "Formerly WW -U -531 • PF - 149 , t IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 VICTAULIC ' IS AN ISO 900 D101IHLO COMPANY Styles 920 and 920N Mechanical -T® Bolted Branch Outlets PRODUCT DESCRIPTION Victaulic Mechanical -T' Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross -type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be r mated to achieve a cross connection. ! Style 920 and Style 920N Mechanical -T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized housings are available, supplied with plated bolts. Styles 920 and 920N All sizes of Style 920 and 920N are rated at 500 psi (3450 kPa) working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or polybutylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical -T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Style 920 Cross FdS ® See Victaulic publication 10.01 for details. See chart on page 5 for pressure ratings. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A -536, grade 65- 45 -12, with orange enamel coating. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice ") • Grade "E" EPDM EPDM (Green color code). Temperature range -30°F to +230 °F ( -34 °C to +110 °C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL Classified in accordance with ANSI /NSF 61 for cold +86 °F ( +30 °C) and hot +180 °F ( +82 °C) NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade "T" nitrile Nitrile (Orange color code). Temperature range -20 °F to +180 °F ( -29 °C to +82 °C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150 °F ( +66 °C) or for hot dry air over +140 °F ( +60 °C). °Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183. a REGISTERED TRADEMARK OF VICTAULIC - L COPYRIGHT 2004 VICTAULIC - PRINTED IN U.S.A. - SKU i WCAS{78NLV 1480 REV G United States- Phone: 1- 800 - PICK -VIC (1. 800.742.5842) • Fax: 610-250-8817 • e -mail: pickvic@victaulic.com Canada • Phone: 905 -884 -7444 • Fax: 905 -884 -9774 • e -mail: viccanadaavictaulic.com Europe • Phone:32 -9- 381 -1500 • Fax: 32 -9 -380 -4438 • e -mail: viceuro@victaulic.be Central and South America • Phone: 610 -559 -3300 • Fax: 610 -559 -3608 • e -mail: vical@victaulic.com j C t a u' i C Australasia • Phone: 86 -21- 58855151 • Fax: 86- 21- 58851298 • e -mail: vicap@victaulic.com 11.02 DIMENSIONS ' Y `� =�'i Max. Dimensions - Inches/millimeters Aprx. Ea I { I SIZE Work. No Fern. Wgt. Each Run X Branch Press. lML Thd. Grv. Lbsikg V � Nominal Inches Style PSI +0.13 V V Fem. 4 a iisk rii, I r mm No. Ida -0.00 T" t e t W Y Z Thd. Grv. "IT N-1,- 1 X 'l (a) 920N 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 w `� o X 15 3450 38,1 51 64 41 136 70 1.5 II X 1 /4 (a) 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 Styles 920 and 920N x 20 3450 38.1 50 64 - 41 136 70 1,5 - w /Grooved Outlet X 1 (a) 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 - X 25 3450 38.1 47 64 - 41 136 70 1,4 - X 1 (a) t 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 X 32 3450 44.5 52 70 76 41 136 76 1.7 1,5 • Y - I X 1 (a) 1 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 X 40 3450 44,5 52 70 79 41 136 83 1.7 1,5 2 X 1 /7 (a) 500 1.50 2.21 2.74 - 1.86 5.64 2.75 3.0 - fV � - �� r�r 1 T r� 65 X 15 920N 3450 38,1 56 70 47 143 10 1,4 � l i - � X 3/. (a) 920N 500 1.50 2.18 2.74 1.86 5.64 2.75 3.0 W lyl X 20 3450 38,1 55 70 47 143 70 1,4 X 1 (a) 500 1.50 2.06 2.74 1.86 5.64 2.75 2.9 - Styles 920 and 920N X 25 920N 3450 38,1 52 70 47 143 70 1,4 - w /Female Threaded Outlet X 1 t (a) 920N 500 1.75 2.30 3.00 3.25 1.86 6.29 3.00 3.5 3.2 X 32 3450 44,5 58 76 83 47 160 76 1.7 1.5 X 1 t (a) 920N 500 2.00 2.28 3.00 3.25 1.86 6.26 3.25 3.6 3.3 X 40 3450 50.8 58 76 83 47 159 B3 1.7 1.6 NOTE: Style 920 and Style 76,1 mm X 1 12 (a) 300 1.50 2.22 2.75 - 1.88 6.46 3.16 3.9 - 920N housings cannot be X 15 920 2065 38,1 56 70 - 48 164 80 1,8 - mated to achieve cross X 3 /4 (a) 920 300 1.50 2.19 2.75 - 1.88 6.46 3.16 3.9 - connections. x 20 2065 38,1 56 70 - 48 164 80 1,8 - X 1 (a) 300 1.50 2.07 2.75 - 1.88 6.46 3.16 3.8 - These new size Style X 25 920 2065 38.1 53 70 - 48 164 80 1,7 NEW 920N products require a HOLE SIZE different hole size than X 1 (a) t 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 the Style 920 it replaces. It 32 3450 44,5 58 76 84 49 160 76 1,6 1.5 for proper installation. X 1 (a) 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 Use caution to assure • X 40 920N 3450 50.8 58 76 84 49 160 83 1,6 1,5 the proper size hole is prepared for the specific 3 X 1 /2 (a) 920N 500 1.50 2.52 3.05 - 2.28 6.15 2.75 3.4 - size and style used. 80 X 15 3450 38.1 64 78 - 58 156 70 1,6 - Failure to use the proper X 3 /4 (a) 500 1.50 2.49 3.05 - 2.28 6.15 2.75 3.4 - hole size could result in 920N x 20 3450 38,1 63 78 58 156 70 1,6 joint leakage and - property damage. X 1 (a) 920N 500 1.50 2.38 3.06 - 2.28 6.15 2.75 3.3 - X 25 3450 38.1 61 78 - 58 156 70 1.6 - X 1'4 (a) t 920N 500 ' 75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 X 32 (b) 3450 44,5 65 83 90 58 156 76 1,8 1,8 X 1 (a) t 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 X 40 (b) 3450 50.8 71 89 90 58 156 83 1,9 1.8 X 2 (a) 920N 500 2.50 2.75 3.50 3.56 2.28 6 75 3.88 4.9 4.6 X 50 3450 63,5 70 89 90 58 ' 99 2.3 2,1 3 X 2 920N 500 2.50 - - 3.75 2.44 5.72 3.88 - 3.8 90 X 50 3450 63,5 - - 95 62 171 99 - 1,8 4 X 1/2(a) 920N 500 1.50 3.03 3.56 - 2.69 7.01 2.75 3.7 100 X 15 3450 38,1 77 90 - 68 178 70 1,8 - X 3/4 (a) 920N 500 1.50 3.00 3.56 - 2.69 7.01 2.75 3.7 - X 20 3450 38,1 76 90 - 68 178 70 1,8 - X 1 (a) 920N 500 1.50 2.88 3.56 - 2.69 7.01 2.75 3.6 - X 25 3450 38.1 73 90 - 68 178 70 1.8 - X 1 (a) t 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 X 32(b) 3450 44,5 78 96 102 68 178 76 1.9 1,8 X 1 (a) 1 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 X 40(b) 345C 50.8 83 102 102 68 178 83 2.0 1.9 X 2 (a) 1 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 X 50 345C 63,5 83 102 102 68 178 99 2,3 2,1 X 2 (a) t 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 X 65 920 3450 69.9 73 102 102 68 186 118 2.6 2,3 X 76.1 mm 920 500 2.75 - - 4.00 2.69 7.34 4.63 - 6.4 3450 69,9 - - 102 68 186 118 - 2,9 X 3 (a) t 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 X 80 920 3450 38,9 B4 114 105 68 196 130 3.8 2,9 108,0 mm X 1 (a) 920N 500 1.75 3.08 3.78 - 2.63 7.64 3.05 5.0 - X 32 3450 44,5 78 96 - 67 194 78 2,3 - X 1 (a) 920N 500 2.00 3.28 4.00 - 2.63 7.64 3.25 5.0 - X 40 3450 50,8 83 102 - 67 194 83 2,3 Table continued on page 3. See notes on page 4. 2 Styles 920 and 920N Mechanical -T" Bolted Branch Outlets • 11.02 DIMENSIONS = =� SIZE Wax. Hole Dimensions - Inches/millimeters Aprx 'Ngt Ea. Run X Branch Work DL. Fem. _ Nominal Inches Style Press. +0.13 Md. Grv. Fen6 LbsJkg _ _ V � mm No. Midas -0.00 T" V # # V # W r Z Thd. Dry. 4O �� r � "' I w �V� \ r�� 108.0 mm X 2 (a) 500 2.50 3.25 4.00 - 2.63 7.64 4.00 4.00 5. S � + � '`� X 50 76,1 mm 920N Midas 63,5 83 102 - 67 194 102 2.5 � 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.00 3450 69,9 73 102 102 67 194 109 203.20 Styles 920 and 920N X 3 (a) 500 3.50 3.31 4.50 4.00 2.63 7.63 4.88 - 6.5 w /Grooved Outlet X 80 920 3450 88.9 84 114 102 67 194 124 - 3,0 5 X 1/7 500 2.00 4.22 4.75 3.16 9.70 3.69 125 X 15 920 3450 50.8 107 121 80 246 94 X 1 (a) 1 920 500 2.00 4.03 4.75 4.75 3.16 9 70 3.69 7.4 7.6 X 40 3450 50,8 102 121 121 80 246 94 3,4 3.4 X 2 (a) t 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 t PM T X 50 3450 63,5 102 121 121 80 246 111 3,7 3,6 V I air MI rii4. i ur / , X 65 920 3450 69.9 92 121 121 80 246 118 3.8 3.6 1..1 X 3 (a) t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 �V� x 80 3450 88.9 97 127 118 80 246 135 3.8 4,0 Styles 920 and 920N 133.0 mm X 2 920N 500 2.50 3.75 4.50 3.17 8.00 3.88 w /Female Threaded Outlet x 50 3450 63.5 95 114 81 203 99 X 3 500 3.50 3.81 5.00 3.00 9.46 5.31 X 80 920 3450 88,9 97 127 76 240 135 139,7 mm X 11121 920N 500 2.00 3.78 4.50 - 3.30 8.23 3.25 X 40 3450 50,8 96 114 - 84 209 83 NOTE: Style 920 and Style X 2 t 500 2.50 3.75 4.50 - 3.30 8.23 3.88 920N housings cannot be X so 920N 3450 63.5 95 114 - 84 209 99 mated to achieve cross 500 2.75 3.63 4.75 - 3.13 9.85 4.63 - 8.8 connections. X 76 mm ( 920 3450 69,9 92 121 - 80 250 118 - 4,0 These new size Style X 76,1 mm 920 500 3.50 - - 4.63 3.16 9.70 5.31 11.0 - NEW 920N products require a 3450 88,9 118 80 246 135 5.0 HOLE SIZE different hole size than X 3 500 3.50 3.81 5.00 4.63 3.16 9.85 5.38 14.0 the Style 920 it replaces, X 88.9 920 3450 88,9 96.80 127 118 80 250 137 6,4 for proper installation. 6 X P/, 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 - 4,8 Use roper size assure is 150 X 32 (b) 920N the 3450 44,5 112 130 130 96 232 83 - 2,2 he proper z hol i prepared for the specific X 1 (a) t 920N 500 2.00 4.40 5.12 5.13 3.79 9.15 3.25 5.4 5.1 size and style used. X 40 (b) 3450 50,8 112 130 130 96 232 83 2,4 2,3 Failure to use the proper hole size could result in X 2 (a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 joint leakage and X 50 3450 63.5 111 130 130 96 232 99 2,7 2.5 property damage. X 2 (a) t 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 X 65 920 3450 69.9 110 130 130 94 267 118 3,8 3.4 X 76.1 mm (a)(b) 920 500 2.75 - - 5.21 3.69 10.51 4.63 - 8. 3450 69.9 - - 132 94 267 118 - 3.8 X 3 (a) t 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8,4 X 80 920 3450 88.9 110 140 130 94 267 135 4.5 3.8 X 4 (a) t 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 X 100 3450 114.3 97 146 137 94 267 159 4.6 4,6 159,0 mm X 11/4 920N 500 1.75 4.43 5.13 3.63 9.40 3.25 X 32 3450 44,5 113 130 92 239 83 X 1 (a) 920N 500 2.00 4.41 5.13 - 3.63 9.40 3.25 7. - X 40 3450 50,8 112 130 - 92 239 83 3,5 - X 2 (a) 920N 500 2.50 4.38 5.13 - 3.63 9.40 3.88 8.0 - X 50 3450 63,5 111 130 - 92 239 99 3.6 - X 76,1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 3450 69,9 111 140 130 92 239 118 X 3 500 3.50 4.31 5 50 5.13 3.63 9.40 5.31 8.10 X 80 920 3450 88.9 110 140 130 92 239 135 205.74 X 108,0 mm 920 `500 4.50 - - 5.38 3.63 9.40 6.12 - 10.0 3450 114,3 - - 137 92 239 155 - 4,5 X 114,3 mm 920 500 4.50 3.81 5.75 - 3.63 9.40 6.25 18.0 - 3450 114,3 96.80 146 - 92 239 159 8.2 - 165,1 mm X 1 920N 500 1.50 3.88 4.56 3.79 9.34 2.75 X 25 3450 38,1 99 116 96 237 70 X 111, 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 X 32 3450 44.5 113 130 96 237 83 X 1 (a) ' 920N 500 2.00 4.41 5.13 3.79 9.34 3.25 X 40 3450 50,8 112 130 96 237 83 X 2 (a) t 920N 500 2.50 4.38 5.13 3.79 9.34 3.88 X 50 3450 63.5 111 130 96 237 99 X 2 1 920 500 2.75 4.01 5.13 - 3.63 10.51 4.63 8.6 7.6 X 65 3450 69,9 110 130 - 92 267 118 3,9 3,4 Table continued on page 4. See notes on page 4. Styles 920 and 920N Mechanical -T' Bolted Branch Outlets 3 11.02 DIMENSIONS SIZE Max. Hole Dimensions - Incheslmillimeters p Run X Branch Work. Dia. Y Z I 1 Nominal Inches Style P ress. +0.13 Apra. Wgt. Ea. v lair mm No" PSI/kPa -0.00 LbsJkg .Ti, ^ r:L ! 165,1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 X 76,1 mm (a)(b) \� r 3450 3 .5 31 5.50 132 3. 63 10.51 1 5.31 3.9 . 2 8.4 3.4 w X 3 (a) T 920 500 3.50 4 31 5.50 5.13 3.63 10.51 5.31 10. X 80 3450 88,9 110 140 130 92 267 135 4,6 3.8 Styles 920 and 920N X 4 (a) T 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 X 100 3450 114,3 97 146 137 92 267 159 4,8 3,8 w /Grooved Outlet 8 X 2 (a) 500 2.75 5.44 6.19 - 4.81 12.42 4.50 11.6 - 200 X 50 920 3450 69.9 138 157 - . 122 316 114 5.3 X 2V2 (a) t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 X 65 3450 69,9 129 157 157 122 316 114 5,3 5.3 t Y 1 X 3 (a) t 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 X 80 920 3450 88,9 135 165 165 122 316 135 5,7 5.3 4pw r X 4 (a) T 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 153 12.5 T � / 920 X 100 3450 114,3 122 171 162 122 316 159 6,9 5.7 1 Ivl Styles 920 and 920N w/Female Threaded Outlet NOTE: Style 920 and Style 920N housings cannot be mated to achieve cross connections. These new size Style NEW 920N products require a HOLE SIZE different hole size than the Style 920 it replaces, for proper installation. Use caution to assure the proper size hole is prepared for the specific size and style used. Failure to use the proper hole size could result in joint leakage and property damage. NOTES 'Tenter of run to engaged pipe end, female threaded outlet only (Dimen- sions approximate). t Available with grooved or female threaded outlet. Specify choice on order. # Center of run to end of fitting, # Female threaded outlets are avail- able to NPT and BSPT specifications. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b) For 76,1 mm threaded outlet, spec- ify 2 BSPT clearly on order. 4 Styles 920 and 920N Mechanical -T' Bolted Branch Outlets • 11.02 FLOW DATA 0 OUTLET SIZE Equivalent Length OUTLET SIZE Equivalent Length I Feet/meter of Pipe Feet/meter of Pipe Nominal Actual Nominal Actual Diameter Out. Dia. Female Diameter Out. Dia. Female 0 InJmm In /mm Grooved Threaded In /mm InJmm Grooved Threaded 0.840 2 2.375 9.0 10.5 M 15 21.3 0 s 50 60.3 2,7 3,2 1 J 3/4 1.050 4 0 242 2.875 11.0 12.5 ill`.., 20 26.7 1.2 65 73.0 3,4 3,8 1 1.315 5.0 3 3.500 13.5 15.5 25 33.7 - 1.5 80 88.9 4,1 4.7 Exaggerated for Clarity VI, 1.660 5.5 6.0 4 4.500 20.0 22.0 Flow test data has shown that 32 42,4 1,7 1,8 100 114.3 6.1 6,7 the total head loss between 1 1.900 7.0 8.0 point (1) and (2) for the Style 40 48,3 2,1 2.4 920, 900N and 929 Mechanical -T' fittings can Formulas for CV Values: best be expressed in terms of the pressure difference across AP = Where: the inlet and branch. The , pressure difference can be Cv- f" Q = Flow (GPM) Cv = Flow Coefficient obtained from the relationship Q = Cv . AP = Pressure Drop (PSI) to the right. Cv Values Pipe Size Pipe Size Pipe Size Values for flow of water at Actual Actual Actual Nominal Outside Nominal Outside Nominal Outside +60 °F ( +16 °C) are shown in Diameter Diameter Cv Diameter Diameter C Diameter Diameter Cv the table at right. Inches/mm Inches/mm Values Inches/mm Inches/mm Values Inches/mm Inches/mm Values 7 2 0.840 1 1.660 2 2.875 17 135 15 21,3 32 42,4 65 73.0 -V, 1.050 1 1900 3 3.500 20 26,7 21 40 48.3 bv " 80 88.9 200 1 1.315 2 2.375 4 4.500 25 33 7 25 50 60.3 100 1 50 114.3 400 APPROVED PRESSURE RATINGS [he information provided below is based on the latest listing and approval data at the time of publication. Listings /Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated Working Pressures Run Size PSI/kPa Actual Nominal Outside Diameter Diameter Outlet Size Pipe Inches/mm Inches/mm Inchea/mm Schedule UL ULC FM 2 - 6 2.875 - 6.625 400 400 400 65 - 150 73,0 • 168.3 All 10 . 40 2755 2755 2755 2 - 4 2.875 - 4.500 All DF 300 300 300 65 - 100 73,0 - 114.3 2065 2065 2065 2 - 4 2.875 - 4.500 All SF 300 300 300 65 - 100 73.0 • 114,3 2065 2065 2065 6 6.625 300 300 250 150 168.3 3 . 4 10 2065 2065 1724 6 6.625 300 300 300 150 168,3 3 30 , 40 2065 2065 2065 8 200 8.625 2 10, 40 2755 - - 8 8.625 300 - 250 200 219,1 3,4 10 2065 - 1724 8 8.625 300 - 300 200 219.1 3,4 30, 40 2065 - 2065 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed /Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna -Flow steel sprinkler pipe manufactured by American Tube Company SF refers to Listed /Approved Super-Ho steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Styles 920 and 920N Mechanical -T"' Bolted Branch Outlets 5 ® TOLCO www.tolco.com NIBCO• Revision 5,�2412001 Fig. 200 - "Trimline" Adjustable Band Hanger MED Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 „ specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. il r Features — _ • (1/2" thru 2 ") Flared edges ease installation for ,,,--c- all pipe types and protect CPVC plastic pipe from ' abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily B e installed around pipe. • (2 thru 8" Spring tension on nut holds it A A securely in hanger before installation. Adjusting \ nut is easily removed. Approvals — Underwriters' Laboratories listed (1/2" thru 8 ") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8 "). Conforms to Federal 1/2 THRU 2 INCH PIPE 2 1/2 THRU 8 INCH PIPE Specifications WW -H -171 E, Type 10 and Manufacturers Standardization Society SP -69, Type 10. MIN Maximum Temperature — 650 °F Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTM' Fig. 200WON. Order By — Figure number and pipe size i + 1 1 ) 1 / 4 ,________ } Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/4 2% 400 11 3/4 3/8 8mm or 10mm 312 21/2 400 11 1 3/8 8mm or 10mm 31/2 2% 400 12 11/4 3/8 8mm or 10mm 3 21/2 400 13 11/2 3/8 8mm or 10mm 3 21/2 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 5% 4 600 27 3 3/8 10mm 51/2 4 600 29 31/2 3/8 10mm 71 5 600 34 4 3/8 10mm 71 5 1000 35 5 1/2 12mm 912 614 1250 66 6 1/2 12mm 101/4 6 1250 73 8 1/2 12mm 131/2 834 1250 136 ® OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH: 951 737 5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800 786.5266 www.tolco.com ® TDLCD www.tolco.com aorandof Revision 9/22/2001 Fig. 65 and Fig. 66 Reversible C -Type Beam Clamps 3/4" and 1 Throat Openings Size Range — (Fig. 65 and Fig. 66) 3/8 ", 1/2" and 5/8" rod Component of State of 4> California OSHPD Approved Material — Carbon Steel with hardened cup point set screw and Seismic Restraints System jam nut Oc 0 Function — Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 1 (Fig. 66). Features — All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bot- B tom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or D down position. Offset design permits unlimited rod adjustment by ��. )E allowing the rod to be threaded completely through the clamp. Open 1 design permits inspection of thread engagement. ,► C Approvals A Underwriters' Laboratories Listed in the USA � K i e • pP — Underwriters f UL ) and Canada (cUL). Factory Mutual Engineering approved. Conforms to >, Federal Specification WW -H -171 E, Type 23 and Manufacturers F Standardization Society SP -69, Type 19. Exceeds requirements of the 4/ 0 111 1 - 4 National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. A Included in our Seismic Restraints Catalog approved by the State of 1ij California Office of Statewide Health Planning and Development. (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro- Galvanized and HDG finish. Order By — Figure number, rod size and finish Fig. 65 Patent #4,570,885 B Fig. 65 D Dimensions • Weights l4r k E Rod Size Max. Rec. Approx. °W , A B C D E F Load Lbs.* Wt. /100 /� 3/8 1 3/4 1 7/16 1 610 28 F 1/2 1'/2 3/4 1 9/16 1'/4 1130 55 5/8 17_ 3/4 1 9/16 17, 1130 55 * Max. loads for clamp with set screw in up or down position. (5 Fig. 66 , A Dimensions • Weights Rod Size Max. Rec. Approx. 0 A B C D E F Load Lbs.* Wt. /100 3/8 1' /•, 114 1 7/16 1 610 28 1/2 17_ 17, 1 9/16 17, 1130 55 5/8 1' /_ 1 L 1 9/16 1 /, 1130 55 * Max. loads for clamp with set screw in up or down position. ® OFFICE /MANUFACTURING FACILITY • ' IF' '; , .E • .:ORONA. CA 92879 • PH. 951.737 5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.cp/ . ., ®TOLCO www,tolco.com ,r,,d or NIB= Revision 8/13/2001 Fig. 69 - Beam Clamp Retaining Strap ®c® Size Range — 3/8" thru 7/8" rod by 4" thru 16" length." Function — To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies O requirements of NFPA 13 (1999) 6- 4.7.1. Important Note — Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mecha- nism of some kind such as a hex nut or the beveled locking slot on the TOLCOTM Fig. 69R will provide a more secure B reliable installation. Approvals — Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). Finish — Pre - Galvanized Order By — Figure number, type, length "B" and rod size being used with beam clamp Note — Minimum return on Strap: 1". Dimensions • Weights II Type Rod Size A Hole Size B ILW//TIVA I I PA I I I II I 1 3/8 7/16 Specify 1/2 9/16 Specify = is, 2 5/8 11/16 Specify V- - .-=A MI 3/4 13/16 Specify 3 3/8 - 7/8 Specify Specify ` Longer lengths are available, consult factory. ■i 1 'S • Office /Manufacturing Facility • 1375 Sampson Ave • Corona, CA 92879 • Ph 909.737 5599 • Fax 909 737 0330 Customer Service • 300 796 5266 IIII www.tolco.com • HDI =P: Item No.: 00243554 - hilti.com Page 1 of I Catalog Anchoring Systems Metal Anchors Internally Threaded Anchors HDI Drop -In Anchor HDI -P Flush Drop -In Anchor HDI -P: Item No.: 00243554 Click to enlarge Technical Data _ Anchor length 3/4 in. Drill bit diameter 1/2 in. Material composition Carbon steel with zinc plating Metal composition Carbon steel Ba se materials Concrete block (solid), Concrete deck (hollow), Stone (l• Additional product Short embedment for pre -cast hollow slabs inform ation - Reliable fastenings in hollow core panels , precast plar Applications slabs Hilti. Outperform. Outlast. Hilti = registered trademark of Hilt! Corp., FL -9494 Schaan, Principality of Liechtenstein © 2001 - 2006, Right of technical and programme changes reserved, S.E. & 0. http: / /www.hilti.com/hoicom /modules /prcat /prca_fuse.jsp ?RANGE OID =10772 4/26/2006 Bulletin 136 Rev.M NM ® Model Fl FR CO Model F1 FR Recessed st Quick Response cn Sprinklers K Model Fl FR Sprinkler Types Standard Upright 4= Standard Pendent P Conventional Vertical Sidewall i Horizontal Sidewall - HSW 1 Deflector r " Model Fl FR Recessed Sprinkler Types = :— Recessed Pendent Recessed Horizontal Sidewall Upright Pendent - HSW 1 Deflector .� Listings & Approvals ' 1� 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) 3. Certified by FM Approvals . . 4. Loss Prevention Council (LPC, UK) LL' �; I F «fi i , 5. NYC BS&A No. 587-75-SA i r 6. Meets MIL- S -901C and MIL -STD 167 -1 7. Verband der Schadenversicherer (VdS, Germany) , 8. NYC MEA 258 -93 -E UL Listing Category Vertical Sidewall Conventional Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV , / •�� loir ., ,, . - ., , , , 4, Patents: US Patent No 6,374,920 Applies to Model Fl FR Vertical Sidewall Sprinklers. = Product Description Horizontal Sidewall Recessed Pendent Reliable Models F1FR and F1FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown) I quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. pands, forcing the bubble smaller and smaller as the liquid The Models F1 FR and Fl FR Recessed automatic sprinklers pressure increases. Continued heating forces the liquid to utilize a 3.0 mm frangible glass bulb. These sprinklers have push out against the bulb, causing the glass to shatter, demonstrated response times in laboratory tests which are opening the waterway and allowing the deflector to distrib- five to ten times faster than standard response sprinklers. This ute the discharging water. quick response enables the Model F1FR and Fl FR Recessed sprinklers to apply water to a fire much faster than standard Application sprinklers of the same temperature rating. Quick response sprinklers are used in fixed fire protec- The glass bulb consists of an accurately controlled amount tion systems: Wet, Dry, Deluge or Preaction. Care must be of special fluid hermetically sealed inside a precisely manu- exercised that the orifice size, temperature rating, deflector factured glass capsule. This glass bulb is specially con- style and sprinkler type are in accordance with the latest structed to provide fast thermal response. The balance of published standards of the National Fire Protection Asso- parts are made of brass, copper and beryllium nickel. ciation or the approving Authority Having Jurisdiction. At normal temperatures, the glass bulb contains the fluid Quick response sprinklers are intended for installation as in both the liquid and vapor phases. The vapor phase can specified in NFPA 13. Quick response sprinklers and stan- be seen as a small bubble. As heat is applied, the liquid ex- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type K Factor Sprinkler Identification Standard - Upright (SSU) and Pendent (SSP) Sprinkler Approval Number (SIN) Deflectors Marked to Indicate Position US Metric Height Organization SSU SSP A" (15mm) Standard Orifice with /" NPT (R)) Thread 5.6 80 22' (56mm) 1,Z3,45,6,7 R3625 R3615 IX," (20mm) Large Orifice with y," NPT (R 8.0 115 23' (58mm) 1,2,3,4,7,8 R3622 R3612 / (17mm) Small Orifice with X" NPT (R)) Thread 4.2 60 22' (56mm) 1,2,8 R3623 R3613 /" (10mm) Small Orifice with X" NPT (RX) Thread 2.8 40 22' (56mm) 1,2,8 R3621 R3611 10mm Orifice XLH with RY Thread 4.2 60 56mm 4,6,7 R3624 R3614 Conventional-Install in Upright or Pendent Position 10mm Orifice XLH with R% Thread 4.2 60 56mm R3674 15mm Standard Orifice with X" NPT (RX) Thread 5.6 BO 56mm 4,6,7 R3675 20mm Large Orifice with 3 4" NPT (R 8.0 115 58mm 4,7 R3672 t ,t .,.. . t ti ii, , — i,: : _ . , tF'.r ti - tea; • _ Upright Pendent Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler I Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread K Facto Sprinkler Approval Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) y," (15mm) /" NPT (R1/2) 5.6 80 22' (56mm) 1,2,3,4,5,7,8 R3615 'T/ (20mm) yi" NFT (R 8.0 115 2.3' (58mm) 1,2,3,8 R3612 / (11mm) }Z" NPT (R1/2) 4.2 60 2.2" (56mm) 1,2,8 R3613 _ %" (10mm) Y" NPT (R'h) 2.8 40 2.2" (56mm) 1,2,8 R3611 10mm RX 4.2 60 56mm 4,7 R3614 (1) Refer to escutcheon data table for approvals and dimensions. 2 5/6" DIA. [66.7mm) 2 1/5' HOLE Du HOLE IN CEILING [.57.2mm1 4 _ I 15 ON 2 5/16" DIA. 158.7mm] (49.2mm1 CLIP r --- -_—_-) r -- 1 X '/2 REDUCER I 1 1 X 1/2" REDUCER TURN COLLAR UNOL TIGHT A GAINS,. BOSS WRENCH OSS I 1 I f L_ J 3 , 1 F ACE FT lNC IG ADJUSTMENT Pl ` � '�,� I CfKIHC DINENSpN CEILING M ard= �J it it ` � 0 ill 1� T O FACT OF CE✓� • (J2mm, i=ra. I -- ,__ l (11. A A•r /) 2 27/32' Du ADJUSTMENT -__— [72.2mmj TJ6FGOLE 1 1 D05_A (1) REFER TO FI A' F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS, /•; REFER IC FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 2 Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Thread K Factor Sprinkler Approval Sprinkler Orifice Size US Metric Height Organizations Number (S N umbber (S identification ) NIN) ye 1/2" NPT (R1/2) 5.6 80 2.2" (56mm) 1, 2, 3, 6, 8 R3685 15mm 1/2" NPT (R1/2) 5.6 80 2.2" (56mm) 4 (1) (1) LPC Approval is for Pendent position only Orientation Deflector to Ceiling Dimension (Min. - Max.) Upright 4" - 12" (102mm - 305mm) frit % Pendent 6" - 12" (152mm - 305mm) Vertical Sidewall I US Patent No. 6,374,920 Model Fl FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations K Factor and Type of Approval Sprinkler Identification Nominal Thread Sprinkler Light Ordinary Number (SIN) Orifice Size US Metric Length Hazard Hazard , "(15mm) y" NPT(R1/2) 5.6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. 1,3oFG04 A% 1' 4 : / J , �I FACE OF FITTING TO - -- 4 J WALL DIMENSION - f 1 1/4' MIN. I [31.8mm1 i -1 t /4" HOLE DU. 1 •8 " 4 ••_ E - 1 :1:". [el.. [572mmJ [7,2mm] [101.6mm- 152.4mm] 4 CEILING TO ., } L , _, 1" X 7/2" REDUCER - O£FLECTOR / _ a ` - -/r-- —� — 1 I 75/16" DIA.' j _ _ I.�'C 1 ,: ". Horizontal Sidewall [49 2,,,,,i '! ?�'� 1i1 2 27/32" D/A. ik -- i �� [72.22m,m1 TURN COLLAR UNTIL -/ \:', }I TIGHT AGAINST SPRINKLER \�`! WRENCH BOSS. AUJU5I ML N! (1) (1) REFER To ESCUTHCFON DATA ,TAR/ F FOR APPROVA1. S AND DIM£NS /?NS. 3. Installation Quick response sprinklers are intended for installation as cleaning fluids. Remove dust by using a soft brush or gen- specified in NFPA 13. Quick response sprinklers and stan- tie vacuuming. Remove any sprinkler which has been dard response sprinklers should not be intermixed. painted (other than factory applied) or damaged in any The Model Fl FR Recessed Quick Response Sprinklers are to way. A stock of spare sprinklers should be maintained to be installed as shown. The Model Fl or F2 Escutcheons illus- allow quick replacement of damaged or operated sprin- trated are the only recessed escutcheons to be used with the klers. Prior to installation, sprinklers should be maintained Model Fl FR Sprinklers. The use of any other recessed escutch- in the original cartons and packaging until used to mini - eon will void all approvals and negate all warranties. mize the potential for damage to sprinklers that would When installing Model Fl FR Sprinklers, use the Model D Spin- cause improper operation or non - operation. kler Wrench. When installing Model Fl FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any Sprinkler Types other type of wrench may damage these sprinklers. Standard Upright Glass bulb sprinklers have orange bulb protectors to minimize Standard Pendent bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER Conventional SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- Sidewall (Vertical, Horizontal HSW1) moval of the protectors before this time may leave the bulb vul- Recessed Pendent nerable to damage. RASCO wrenches are designed to install Recessed Horizontal Sidewall HSW1 sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Finishes MP) TO REMOVE THE PROTECTORS. Standard Finishes Sprinkler Escutcheon Temperature Ratings Bronze Brass Sprinkler Max Ambient Bulb Chrome Plated Chrome Plated (3) Classification Temperature Temp. Color White Polyester Coated White Painted (3) °C °F Ordinary 57 135 100°F (38°C) Orange Special Application Finishes Ordinary 68 155 100°F(38°C) Red Sprinkler Escutcheon Intermediate 79 175 150°F (66°C) Yellow Bright Brass Bright Brass Intermediate 93 200 l5OF(66°C) Green Black Plated Black Plated High (1) 141 296 225 °F(10PC) Blue Black Paint Black Paint (1) Not available for recessed sprinklers. Off White Off White Escutcheon Data Satin Chrome Satin Chrome Escutcheon Faced Fitting (1) Other finishes and colors are available on special order. A Adj rt toCelingor Consult the factory for details. coknension Model Wel Dimension 12) FM Approvals is limited to bronze and brass, chrome or black 1X" plated finishes only. Max Recess (38.1mm) Yi6 - '3;8 ' 1 FP Push - on/Thread -off escutcheon Fl 1,2,4,8 Min Recess 3;" (5mm -24mm) (19.1mm) Ordering Information 1y " Specify: F2 1,2,3,4,5,7,8 Max Recess (38.1mm) 36 ' y e " Min Recess '37 (5mm -17mm) 1. Sprinkler Model (24mm) 2. Sprinkler Type FP 1,2 Max Recessed ' ix' (38.1mm) 3. Orifice Size Push-0n/ ! 11 mm) 4. Deflector Type Thread off 1,2 Min Recessed (24mm) 6 1 ^(25.4n) 5. Temperature Rating No Dimensional Figure for FP 6. Sprinkler Finish 7. Escutcheon Type Maintenance 8. Escutcheon Finish (where applicable) The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system Note: When Model F1FR Recessed sprinklers are maintained in accordance with NFPA 25. Do not clean ordered, the sprinklers and escutcheons are packaged sprinklers with soap and water, ammonia or any other separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting lite and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States. Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. e R P p er ReliabW (800)431 -1588 Sales Offices (800)848-6051 Sales Fax Revision lines indicate updated or new data (914)668-3470 Corporate Offices www.reliablesprinkler. corn Internet Address EG. Printed in U. S.A. 7/05 P/N9999970027