Plans J T,'= 1 D APR 19 2012 • CITY OF TIGARD 707.4* BUILDING DIVISION 1 _. . I i 1 r I i 1 r '1 ■ I I I I I 1 1 1 r- -I-g--.....i...1- ..- / —\\ - >a • l I 3 ' -- - I , u.i -- I I o Q in _:l E W N r 1 I i Z in I; 1 • E v Oa) Y:1 3,384 NET SF 1,729 NET SF 2,122 NET TENANT A ; TENANT B - 'TENANT C TENANT 0 : I cc SF 3,004 NET SF I a o `^ o (1 (116 SF SUPPORT I ( +61 SF SUPPORT -• ( +74, SF SUPPORT = ( +104 SF SUPPORT = I t � �; o Q • T. = - - E 3.5000 NEI' LEASABLE) .1 1,790 NET LEASABLE) 2,196 NET LEASABLE) 3,108 NET LEASABLE) a 0 N I I , 1. --1 a 1 i ' t S UPPORT _% ' • ET SF E i L ' . • FACP 0 � I • - - ` l❑r ❑ e I w a W N 1 H . p U O O) U Sa Y C6 ' LEGEND . PHONE o o LINES • I w N V ,�, © ZONE 4 LOJ OUTSIDE BELL -- POTTER 12VDC 10" Z a CURRENT -- .12A QQF GARD Approved i::C ....... [‘..1--- Z N SMOKE DETECTOR 5 YS TEM SENSOR 2W B 0 Approved [ ] ° s w .) Q See Letter to: Follow [ ] U U Q rn L, IFA CPI FIRE PANEL -- SILENT KNIGHT 5104 Attached [ ] D i N w r - o oww 12 VOLT 12 VOLT Permit Number: © ZONE 5 Ad.. - - v Y �- . Z D r 7 AMP 7 AMP ° 0 PULL STATION - - SYSTEM SENSOR BG 10 $y; i�ii��� Date: �' 2 d ��� Y ai ° O z o 0 42" - 48" BOTTOM OF DEVICE TOFF ~ N' ,9051) _ TAMPER SWITCH 1 DEDICATED 120 VAC Approved job D PROJECT # 18707-12 _ • ) S hall be on ob site. 04 - -12 SUBMITTALS FR FLOW SWITCH _ SHEET 'BTU RISER ® ZONE 3 FIRE ALARM • M ZONE;? OFFICE COPY SCALE 1 16" = 1. -0" sicNED LARRY = • - - DRAWN BY JARED / S E E of 1 E T PROJECT # 18707 -12- - ei FIRE ALARM ACCESSORY N .! , _.1% >l A ii 1, f ;1, - 5 2 © 2_ - 6 Cpl 10 SILENT An 19 2012. 51048 Fire Control KNIGHT arry oF MAID Communicator • 0 BUILDING DIVISION by Honeywell The speed, reliability and value of digital communications from the company you can trust As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104B Fire Control Communicator has become the industry standard by proving itself in years of field- tested operation. This six -zone fire control communicator provides fast, reliable digital communication of fire and trouble conditions. It transmits via ordinary phone lines — eliminating the need for expensive leased line arrangements. Use it as a stand - alone, or incorporate it into your existing system. Why spec any other digital communicator? Go with the industry standard — the 5104B Fire Control Communicator from Silent Knight. For more information, please call 1- 800 - 328 -0103. Model 5104B the central station. If one of the Fire Control Communicator telephone lines faults for more than The Silent Knight Model 5104B is a 60 seconds, it will automatically •� _- • six -zone fire control communicator switch to the other to report the 0 ` t. -4 7 providing digital fire reporting over e. c P 9 9 P 9 failur a xe ordinary telephone lines, The communicator will signals -a -- • eliminating the need for costly activation, restoration and trouble leased lines. Its UL 864 and NFPA conditions on any of six inputs. If x 72 approved for monitoring local an application requires a different .1 O evacuation controls. input configuration, the individual "— ,_..x As a stand -alone unit, it can be input styles may be changed by iv "y used to monitor: using a Model 7181 Fire Zone Model 5104B • Sprinkler systems for waterflow, Converter Module. The 7181 also supervisory, and gate valve allows use of two -wire type smoke Dual phone line interface Automatic tamper conditions. detectors, instead of the normal self tests every 24 hours with report four -wire contact type, for sent to central station. • Automatic fire detection systems automatic fire detection • for structures that are not Reports in SIA and most major applications. communications formats. required to have a fire alarm system but want property Features • 60 hours of standby power. • Operates on loop start phone lines • UL 864 Listed as an NFPA 72 protection (e.g. to call the fire ahead of the building PBX system. department after hours). Central Station or Remote Station • Monitors dry contact alarms, protected premise unit. • A single, programmable output is ry provided for alarm or dialer failed • trouble and supervisory outputs, FM approved. p ry p • Can be used as a stand -alone or as conditions (cannot be used for then transmits a separate code a add-on DACT. evacuation purposes). for each. The Model 51048 is fully • Six fully supervised inputs: one Class A (Style D) input, and five supervised. Its microprocessor Class B (Style A) inputs. constantly runs programs to • Downloadable for remote monitor AC, standby battery, zone programming. inputs and telephone line • Fuseless overload protection with connections. If a fault condition is automatic reset circuitry and fault • detected, it sounds a local trouble indicators — eliminates the cause of audible and reports the condition to most field calls. FIRE ALARM ACCESSORY 5104B Fire Control Communicator Specifications Mechanical: Electncal _ Dimensions: 12.25" W x 14.5" H x 3.0" D Add-on Applications - UL Listed (31.1cmWx36.8cmHx7.6cmD) Input. 120 VAC 60 Hz 40 watts Weight: 15 lbs. (6.75 kg) Current Color Red Standby 50 mA p Alarm 135 mA Optional Accessories: Stand Alone Applications 5230 Remote Annunciator /Programmer Input 120 VAC 60 Hz 40 watts 5561 Download Package Standby 12 volt 7 amp hour rechargeable battery 7181 Fire Zone Converter Module 5230 Remote Annunciator (three maximum per system) 7860 Telephone Connecting Cord for RJ31X Jack (2 required) 6712 12 volt, 7AH rechargeable battery Load: 60 mA standby 120 mA alarm Communication Formats: SIA, SK 3/1, Sescoa 3/1, Contact ID, Indicator Lights (LEDs): SK 4/2, Radionics BFSK Power On (Green) Approvals: Trouble Silenced (Yellow) UL Listed - UL864 /NFPA 72 Central and Remote Supervising Until Trouble is Cleared /Flashing = Supervisory Station Fire Alarm System Service. Dialer Failure (Yellow) FM Approved Telephone Line Fault (2 Red) CSFM Approved Inside Cabinet at L1 and L2 Inputs MEA Telephone Requirements: FCC Registration #. AC698R- 17462 -AL -E RINGER EQUIVALENCE 0.0B Type of Jack: RJ31 X (2 required) Model 5230 Remote The Model 5560 SKSS Alphanumeric Annunciator Downloading Package The 5104B can be programmed Allows for remote programming through the use of the optional and status checking of the 5104. L s Model 5230 Remote Alphanumeric Includes a 3 1/2 -inch disk and i f Annunciator. Programming options Silent Knight proprietary modem. w "_ I include: telephone numbers, Allows the installing company to .m vr• 2, — reporting format, account number, view the default programming, . � loop response times (electronic modify it, and if necessary, retard), test time, output activation, troubleshoot the system. Designed `4 ® ® a „ a �_ user and installer codes. System to be used on an IBM or f programming is stored in a non- compatible PC. The downloading ." volatile EEPROM chip which is software also contains programs for reprogrammable hundreds of times. other Silent Knight downloadable Model 5230 The 5104B accommodates up to products. 5 1/4 -inch disks available three remote annunciators via a upon request. four -wire connection. A quick- connect plug allows temporary connection of the annunciator for programming. • FIRE ALARM ACCESSORY 5104B Fire Control Communicator SILENT KNIGHT MODEL 5104B 120VAC 60 Hz 6 Channel Silent Knight Communicator Model 5230 Class A Input 0 (optional) (supervised) Remote Annunciator (3 max per system) 0 0 Class B Inputs (supervised) O MB- G10 -12 -R Heat detectors, manual O (optional) pull stations and Tel. Line #1 contact type O Model 6712 To RJ31 X smoke detectors _ 12VDC 7 AH Tel. Line #2 MODEL 5104B BLOCK DIAGRAM Stand -alone Automatic Fire Detection Application (For Communication Only) ARCHITECT /ENGINEER and send the alarm signal on one or The digital communicator shall provide SPECIFICATIONS both lines without the addition of any a secondary power supply utilizing The contractor shall provide an more equipment. It shall test each rechargeable batteries. The secondary approved digital communicator to telephone line (number) at alternating supply shall be capable of supplying transmit the fire alarm and supervisory 24 -hour intervals in accordance with power, under maximum normal load, and trouble signals to a central station. NFPA 72. It shall sound a local trouble for 24 hours for central station or The digital communicator shall be UL signal if the telephone service is proprietary applications or 60 hours for or FM listed for fire reporting to a interrupted for longer than 60 seconds remote supervising station system central station and shall conform to the and it shall transmit a signal indicating application in accordance with NFPA requirements of NFPA 72. the loss of phone line service to the 72. central station over the remaining The communicator shall be able to The digital communicator shall provide phone line. A signal shall also be transmit all signals in the Standard SIA power and necessary components for transmitted to indicate the restoral of format (Security Industry Association). six supervised detection circuits. One phone service. The shall be Class A (Style D) and five shall control /communicator shall be able to The alarm signals transmitted to the be Class B St le A . The detection central station shall indicate which of ( Y ) report the loss of either phone line circuits shall accommodate sprinkler without regard to which phone line the six zones is in alarm and which flow switches, gate valve supervisory failed first. If both lines fail, a local zones are in trouble. Restoral from switches, thermal detectors and signal shall sound. alarm or trouble shall be capable of contact -type smoke detectors communicating to Silent Knight, and intermixed as desired and permitted by The control /communicator shall have other industry standard receivers. NFPA 72. the ability to send a test signal to the central station every 24 hours. The test The control /communicator shall have signal shall be able to be transmitted at the capability to supervise two a specific time of day or night by telephone lines, seize the phone line setting a program within the panel. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are PN 350349, Rev C1 by Honeywell subject to change without notice. For more information, contact Silent Knight ©2010 Honeywell International Inc. 12 Clintonville Road, Northford, CT 06472 -1610. Phone: (800) 328 -0103, Fax• (203) 484 -7118. www.silentknight.com FIRE ALARM ACCESSOR • • 5104B Fire Control Communicator 120VAC 60 Hz UL- LISTED LOCAL FIRE SILENT KNIGHT CONTROL MODEL 5104B 6 Channel Silent Knight (optional) 5230 Communicator al) (optional) Remote Annunciator Alarm Contact (3 max per system) (N.O. Typical) Trouble Contact Tel. Line #1 To RJ31X (N.C. Typical) Tel. Line #2 • MODEL 5104B BLOCK DIAGRAM Add -On DACT Application SILENT KNIGHT MODEL 5104B 120VAC 60 Hz _ 6 Channel Silent Knight Class A Input Communicator Model 5230 (supervised) (optional) Max 5 waterflow devices as per NFPA 72 Remote Annunciator _ (3 max per system) 0 O Class B Inputs Wheelock (supervised) O ► MB- G10 -12 -R Gate valve tamper or O Tel. Line #1 To RJ31X supervisor -must connect t normally open O Model 6712 12VDC 7 AH Tel. Line #2 MODEL 5104B BLOCK DIAGRAM Stand -alone Waterflow Application ' B PS 20 -coo co 2 Th ,SlZG\SZOG 9 • Photoelectric Smoke Detectors off System Sensor i3' series smoke detectors represent significant advancement in conventional detection. The i family is founded on three principles: installation ease, intelligence, and instant inspection. Features Installation ease. The 1 line redefines installation ease with its • Plug -in detector line, mounting base included plug -in design.This allows an installer to pre -wire bases (included with heads). The large wire entry port and in -line terminals provide • Large wire entry port ample room for neatly routing the wiring inside the base The base • In -line terminals with SEMS screws accommodates a variety of back box mounting methods as well as • Mounts to octagonal and single -gang back boxes, 4- square back direct mounting with drywall anchors. To complete the installation, 1 boxes, or direct to ceiling heads plug into the base with a simple Stop -Drop 'N Lock" action • Stop -Drop 'N Lock attachment to base Intelligence. 1 detectors offer a number of intelligent features • Removable detector cover and chamber to simplify testing and maintenance. Drift compensation and Built-in remote maintenance signaling smoothing algorithms are standard with the 1 line to minimize • nuisance alarms. 2 -wire i detectors can generate a remote LED- • Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W -MOD2 • Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i Wide-angle, dual color LED indication protocol The SENS -RDR, a wireless device, displays the sensitivityof i • detectors in terms of percent - per -foot obscuration. • Loop testing via EZ Walk feature • Built -in test switch Instant inspection. The 1 series provides wide -angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of- sensitivity, alarm, or freeze trouble. When connected to the 2W -MOD2 loop test/maintenance module or a panel with the 1 protocol, the EZ Walk loop test feature is available on 2 -wire 1 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings ® P) MEA MSFM Cus LISTED .v9 ROVE D 1. 1161 approved approved 5911 3011446 7272- 1653152 290-01 -E 2093 3180932 (i)Smoke Detector Specifications ISpecifi - ations Smoke detector shall be a System Sensor is Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems The detector shall be a photoelectric type (Model 2W -B, 4W -B) or a combination photoelectric/thermal (Model 2WT -B, 4WT -B) with thermal sensor rated at 135 °F (57 2 °C). The detector shall include a mounting base for mounting to 31/2-inch and 4 -inch octagonal, single -gang, and 4 -inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors Wiring connections shall be made by means of SEMS screws The detector shall allow pre - wiring of the base and the head shall be a plug -in type The detector shall have a nominal sensitivity of 2.5 percent - per -foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms The detector shall provide dual - color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT -B, 4WT -B) conditions When used in conjunction with the 2W -MOD2 module, 2 -wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually ghOgtd Specifications Operating Voltage Nominal 12/24 V non - polarized Minimum 85V Maximum 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2 -wire 50 pA maximum average, 4 -wire 50 VA maximum average Maximum Alarm Current 2 -wire 130 mA limited by control panel, 4 -wire 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2 -wire 100 NA, 4 -wire n/a Alarm Contact Ratings 2 -wire. n/a, 4-wire' 0 5 A @ 30 V AC/DC A Ad S • cifications Dimensions (including base) 5.3 inches (127 mm) diameter, 20 inches (51 mm) height Weight 6 3 oz (178 g) Operating Temperature Range 2W -B and 4W -B 32 °F to 120 °F (0 °C to 49 °C), 2WT -B and 4WT B. 32 °F to 100 °F (0 °C to 37 8 °C) Operating Humidity Range 0 to 95% RH non - condensing 1 hermal Sensor 135°F (57 2 °C) fixed Freeze Trouble 2WT -B and 4WT -B only 41 °F (5 °C) Sensitivity 2 5 % /ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4 -inch octagonal back box Single -gang back box 4 -inch square back box with a plaster ring Direct mount to ceiling 11-ft I % CCU (ODInd ••tio, LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information ,:3 Vkaud.1 Tittirq 2W-B No 2 -wire 130 mA max. limited by control panel 2WT -B Yes 2 -wire 130 mA max limited by control panel 4W -B No 4 -wire 20 mA @ 12 V, 23 mA @ 24 V 4WT -B Yes 4 -wire 20mA @12V,23mA @24V Accessories 2W -MOD2 2 -wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77 -AB2 Retrofit adapter bracket, 66 inch (16 76 cm) diameter ©1009 system Sensor 3825 Ohio Avenue • St Charles, IL 60174 hod.. spenacatpnssubHt1°°n°r °t°ev„4,ystemsmsor corn h. 7/1 0 ° Phone 800- SENSOR2 • Fax 630 - 377 -6495 crrentpred �s -03nso ngb i'i °rt�s data sheet lGv in ° 2-- 006 C0 DF- 52004:A1 • F -050 BG-1 2 Series 0144 Flre•uTeALarmS Manual Fire Alarm Pull Stations by Honeywell Conventional Initiating Devices General The Fire-Lite BG -12 Series is a cost - effective, feature - packed FIRE series of non -coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end -user in mind. The BG -12 Series features a variety of mod- els including single- and dual- action versions. - - The BG -12 Series provides Fire-Lite Alarm Control Panels (FACP5), as well as other manufacturers' controls, with a man- I PUSH IN I ual alarm initiating input signal. Its innovative design, durable P ULL DOWN construction, and multiple mounting options make the BG -12 Series simple to install, maintain, and operate. Features • Aesthetically pleasing, highly visible design and color. • Attractive contoured shape and light textured finish. • Meets ADA 5 lb. maximum pull- force. F ire-LITe • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Easily operated(single - or dual- action), yet designed to pre- vent false alarms when bumped, shaken, or jarred. • PUSH IN /PULL DOWN handle latches in the down position to clearly indicate the station has been operated. Construction • The word "ACTIVATED" appears on top of the handle in • Cover, backplate and operation handle are all molded of bright yellow, further indicating operation of the station. durable polycarbonate material. • Operation handle features white arrows showing basic opera- • Cover features white lettering and trim. lion direction for non-English-speaking persons. • Red color matches System Sensor's popular SpectrAlert® • Braille text included on finger -hold area of operation handle Advance horn /strobe series. and across top of handle. • Multiple hex- and key -lock models available. Operation • U.S. patented hex -lock needs only a quarter -turn to lock/ unlock. The BG -12 manual pull stations provide a textured finger -hold • Station can be opened for inspection and maintenance with- area that includes Braille text. In addition to PUSH IN and PULL out initiating an alarm. DOWN text, there are arrows indicating how to operate the sta- • Product ID label viewable by simply opening the cover; label lion, provided for non - English- speaking people. is made of a durable long -life material. Pushing in and then pulling down on the handle activates the • The words "NORMAL" and "ACTIVATED" are molded into the normally -open alarm switch. Once latched in the down position, plastic adjacent to the alarm switch (located inside). the word "ACTIVATED" appears at the top in bright yellow, with a • Four - position terminal strip molded into backplate. portion of the handle protruding at the bottom as a visible flag. • Terminal strip includes Phillips combination -head captive 8/32 Resetting the station is simple: insert the key, twist one quarter - screws for easy connection to Initiating Device Circuit (IDC). turn, then open the station's front cover, causing the spring - loaded operation handle to return to its original position. The • Terminal screws backed -out at factory and shipped ready to alarm switch can then be reset to its normal (non - alarm) position accept field wiring (up to 12 AWG /3.1 mm2). manually (by hand) or by closing the station's front cover, which • Terminal numbers are molded into the backplate, eliminating automatically resets the switch. the need for labels. • Switch contacts are normally open. • Can be surface - mounted (with SB -10 or SB -I /O) or semi- flush mounted. Semi -flush mount to a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box. • Backplate is large enough to overlap a single -gang backbox cutout by 1/2" (1.27 cm). • Optional trim ring (BG12TR). • Spanish versions (FUEGO) available (BG- 12LSP, BG- 12LPSP). • Designed to replace the Fire-Lite legacy BG -10 Series. • Models packaged in attractive, clear plastic (PVC), clam- shell- style, Point -of- Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station. DF- 52004.A1 • 04/22/08 — Page 1 of 2 Specifications Agency Listings and Approvals PHYSICAL SPECIFICATIONS: The listings and approvals below apply to the BG -12 Series pull stations. In some cases, certain modules may not be listed by pull station SB-1/0 SB -10 certain approval agencies, or listing may be in process. Consult factory for latest listing status. Height 5 inches 5 inches 5.5 inches • C(UL)US: S711 • (13.97 cm) (14.23 cm) (13.97 cm) • FM Approved Width 4.121 inches 4.222 inches 4.121 inches • CSFM: 7150-0075:184 (10.47 cm) (10.72 cm) (10.47 cm) MEA: 67-02-E • Depth 1.39 inches 1.439 inches 1.375 inches • Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; (3.53 cm) (3.66 cm) (3.49 cm) 52004dim w 6,632,108. ELECTRICAL SPECIFICATIONS: Product Line Information Switch contact ratings: gold - plated; rating 0.25 A @ 30 VAC or BG -125: Single- action pull station with pigtail connections, hex VDC. lock. ENGINEERING /ARCHITECTURAL SPECIFICATIONS BG - 12SL: Same as BG - 12 with key lock. Manual Fire Alarm Stations shall be non -code, with a key- or BG -12: Dual - action pull station with SPST N/O switch, screw hex - operated reset lock in order that they may be tested, and so terminal connections, hex lock designed that after actual Emergency Operation, they cannot be BG -12L: Same as BG -12 with key lock. restored to normal except by use of a key or hex. An operated BG- 12LSP: Same as BG -12L with English /Spanish (FIRE/ station shall automatically condition itself so as to be visually FUEGO) labeling. detected as activated. Manual stations shall be constructed of BG- 12LOB: Same as BG -12L with "outdoor use" listing. red colored LEXAN (or polycarbonate equivalent) with clearly Includes outdoor listed backbox, and sealing gasket. visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, BG -12LO: Same as BG -12L with "outdoor use" listing. Does 1.00 inches (2.54 cm) or larger. Stations shall be suitable for not include backbox. surface mounting on matching backbox SB -10 or SB -I /O; or BG -12LA: Same as BG -12L with auxiliary contacts. semi -flush mounting on a standard single -gang, double -gang, or BG- 12LPS: Dual- action pull station with pre - signal option. 4" (10.16 cm) square electrical box, and shall be installed within BG- 12LPSP: Same as BG -12LPS with English /Spanish (FIRE/ the limits defined by the Americans with Disabilities Act (ADA) or FUEGO) labeling. per national/local requirements. Manual Stations shall be Under- writers Laboratories listed. SB -10: Surface -mount backbox, metal. NOTE: The words " FIRE/FUEGO" on the BG -12LSP shall appear SB -I /O: Surface mount backbox, plastic. (Included with BG - on the front of the station in white letters, approximately 3/4" 12LOB.) (1.905 cm) high. BG12TR: Optional trim ring for semi -flush mounting. 17003: Keys, set of two. (Included with key -lock pull stations.) 17007: Hex lock, 9/64 ". (Included with hex -lock pull stations.) 4 ,4 NOTE: For addressable BG -12LX models, see data sheet DF- t' ^l ; 52013. A 2 W i 1 a 1 EMPUJEY P . PU9#t llli 4 f HALE HACLA ABAJO _.R PULL DOWN t - �. 4 . z 'I Flre•Lite® Alarms, SpectrAlert® Advance, and System Sensor® are registered trademarks of Honeywell International Inc. ®2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. ■ lb tlNEUIINC 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in theU.S. For more information, contact Fire•Lite Alarms. Phone: (800) 627 -3473, FAX: (877) 699 -4105 www.ftrelite corn Page 2 of 2 — DF -52004 Al • 04/22/08 FP5 20IZ.- POTTER � BELLS The Symbol of Protection PBA -AC & MBA -DC UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC • I2VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150 °F (-40° to 66 °C) (Outdoor use requires weatherproof backbox ) Termination: AC Bells - 4 No. 18 AWG stranded wires ® ®M •: DC Bells - Terminal stnp * Finish: Red powder coating Optional: Model BBK -1 weatherproof backbox Model BBX -I deep weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general Notes: signaling devices. They have low power consumption and high decibel I. Minimum dB ratings are calculated from integrated sound pressure ratings. The unit mounts on a standard 4" (101 mm) square electrical box measurements made at Underwriters Laboratones as specified in UL for indoor use or on a model BBK -1 weatherproof backbox or BBX -1 Standard 464. UL temperature range is -30° to 150°F ( -34° to 66 °C). deep weatherproof backbox for outdoor applications. Weatherproof 2. Typical dB ratings are calculated from measurements made with a backbox model BBK -1, Stock No 1500001. conventional sound level meter and ate indicative of output levels in an actual installation. 3 ULC only applies to MBA DC bells Size itches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft. (3m) (2) 10 ft. (3m) (I) 6(150) 12VDC MBAl26 1750070 .12A 85 76 8 (200) 12VDC MBAI28 1750080 .12A 90 77 10 (250) 12VDC MBAl210 1750060 .12A 92 78 6 (150) 24VDC MBA246 1750100 .06A 87 77 8 (200) 24VDC MBA248 1750110 06A 91 79 10 (250) 24VDC MBA24I0 1750090 06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* 17A 94 77 10 (250) 24VAC PBA2410 1810024* 17A 94 78 6 (150) 120VAC PBA 1206 1806120* .05A 92 83 8 (200) 120VAC PBAl208 1808120* .05A 99 84 10(250) 120VAC PBAI2010 1810120* .05A 99 86 All DC bells are polanzcd and have built -in transient protection. * Does not have ULC listing. A INA R N I N G In outdoor or wet installations, bell must be mounted with weatherproof backbox. BBK -1 or BBX -I. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone- 800- 325- 3936 /Canada 888-882-l833 • www pottersignal com PRINTED IN USA MFG 45400776 • REV Y PAGE I OF 2 5/08 1 = _ POTTER BELLS _„ ® The Symbol of Protection PBA -AC & MBA -DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. 1 Fig. 3 A.C. BELLS WI IITE (IN) BI MIME (OUT) (250) e „ I FROM PANEL IL- � (200) 6^ I PANFL OR (150) t� I 1•R O CO D HELL I � _\� r _ .�Cl: llyl _ BLACK (OUT) CAUTION. WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN 2 11/16" [._ (68) NOTES. DWG), 776-1 I WHEN LSING AC RILLS. TERMINATE EACH EXTRA WIRE SEPAL%TILY AFTER LAST BILL 2 ENT -OF -LINE RESISTOR IS NOT REQUIRED ON AL RFI LS nuC TTb) Weatherproof Backbox Dimensions Inches (mm) Fig 2 FACP Box has one threaded 1/2" conduit entrance Id • ' 5 3/4" O 33/6' 5 j To Next • (146) On) (127) Device or End-of-Line esi or L I .� Resistor I J 1 5 /S" (66) — I (e1) 4 I /3" jjpS) I nstallation IMO. 7762 I The bell shall be installed in accordance with NFPA 13, 72, or local AI-IJ. The top of the device shall be no less than 90" AFF and I not less than 6" below the ceiling. _ : 3. Remove wiring gong. x 3 Connect wrong (sec Fig 3). 01 4. Mount bell mechanism to backbox (bell mechanism must be / OD mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong) `s\ 6. Test all bells for proper operation and observe that they can t3E3x -( be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). WARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA 5.1FG ,1)5400776 - REV Y PAGE 2 OF 2 5/08