Loading...
Specifications FPS 2o©9- oo 16 Li- - 7 12 cj S ■/ F‘w.1 7 SIGNALING SYSTEM SOLUTIONS, INC. 6816 NE Highway 99 Vancouver, WA 98665 Ph: 360.694.9199 Fax: 888511.7734 Fire Alarm Special Districts Of Oregon 7125 SW Hampton St. Portland, OR 97223 SCOPE: Installation of (1) SK Fire alarm control panel to replace the existing fire panel that is no longer working. Change out addressable devices with SK devices for compatibility. Add notification appliances per customer request meeting manufacturers instruction for spacing. Add 4 manual pull stations per customer request for manual evacuation. 1 � &1�t- - /0013 Co - x(P L mo- PF frtsc-004, ovo o 3 � Prepared by: Paul E. Siefer, CET Signaling System Solutions, Inc. OR LEA # 3636LEA EXP: 10/2011 NICET 124478 EXP: 12/2011 WA: SIGNASS941Q0 ORCCB: 173274 Signaling Systems Solutions, Inc. CCB: 173274 Current Draw Work Sheet WA CL: SIGNASS941Q0 • Number of Device Devices Current per device Stanby Current Alarm Current standby:200 mA 200 mA SK 5700 FACP 1 Alarm:325 mA 325 mA standby: mA mA Alarm: mA mA standby: mA mA Alarm: mA mA standby: mA mA Alarm: mA mA standby: mA mA Alarm: mA mA (A) Current Subtotals: 200 mA _325 mA Smoke Detectors standby: This is an Alarm: standby:. addressable Alarm: standby: fire panel - all Alarm: standby: mA mA devices for max Alarm: mA mA standby: mA mA # of devices in Alarm: mA mA standby: mA mA panel listing Alarm: mA mA (B) Current Subtotals: NOTE - Addressable panel - Current draw not required for above listed devices Notification Appliances SS P2R 15Cd 7 0.069 48 mA SS P2R 30 Cd 2 0.097 19 mA SS SR 15 Cd 4 0.066 26 mA mA mA (C) Current Subtotals 93 mA (D)Total Current rating of all devices in sys. (add totls of A -C)x .001 .2 Amps .42 Amps (E)Number of standby hours. (24 or 60 for NFPA 72 Chpt 1,1- 5.2.5): 24 -Hrs (F)Multiply lines D (standby current) and E Total standby AH 4.8 Ah (G)Alarm sounding period in hours. (5 min = .0833 hours) .0833 -Hrs (H)Multiply lines D (alarm Current) and G totals Total alarm AH .034 Ah (I) Add lines F and H. Total AH required _4.834 Ah Date: 10/22/09 Project Name: Special Districts of Oregon Project Address:7125 SW Hampton St PDX 97223 1 „� SENSOR Premises: Circuit: SPECIAL DISTRICTS OF OREGON Class B @ 14 AWG 7125 SW HAMPTON ST. Filtered (DC) 24 -volt Supply (2 amp circuit) PORTLAND, OR 97223 Starting Voltage = 20.4 Prepared By: Notes: PAUL SEIFER CURCUIT- NAC1 -1 SIGNALING SYSTEM SOLUTIONS, INC. 6816 NW HIGHWAY 99 VANCOUVER, WA 98665 360.450.8945 ype and Model , Candela Current Next Total 12 14 16 18 fall Hom /Strobe (2 Wire) P2R 15 0.069 6 6 20.39 20.38 20.37 20.36 /all Strobe SR 15 0.066 43 49 20.33 20.28 20.21 20.10 fall Strobe SR 15 0.066 25 74 20.30 20.23 20.14 ' 19.98 fall Horn /Strobe (2 Wire) P2R 30 0.097 15 89 20.28 20.21 20.10 19.92 fall Horn /Strobe (2 Wire) P2R 15 0.069 27 116 20.27 , 20.19 20.06 19.86 fall Horn /Strobe (2 Wire) P2R 15 0.069 42 158 20.25 20.17 20.03 19.82 Total current /amps 0.436 vdc loss 0.15 10.23 0.37 0.58 a- • F 1 SYSTEM SENSOR Premises: Circuit: SPECIAL DISTRICTS OF OREGON Class B @ 14 AWG 7125 SW HAMPTON ST. Filtered (DC) 24 -volt Supply (2 amp circuit) PORTLAND, OR 97223 Starting Voltage = 20.4 Prepared By: Notes: PAUL SEIFER CURCUIT- NAC1 -2 SIGNALING SYSTEM SOLUTIONS, INC. 6816 NW HIGHWAY 99 VANCOUVER, WA 98665 360.450.8945 ype and Model Candela Current Next Total 12 14 16 18 Tall Hom /Strobe (2 Wire) P2R 15 0.069 25 25 20.35 20.32 20.27 1 20.20 fall Strobe SR 115 0.066 45 70 20.27 20.19 20.07 19.88 fall Hom /Strobe (2 Wire) P2R 30 0.097 20 90 20.24 20.15 1 20.00 19.76 fall Strobe SR 15 0.066 20 110 20.22 20.11 1 19.94 19.67 fall Horn /Strobe (2 Wire) P2R 15 0.069 30 140 20.19 ' 20.07 19.88 19.57 fall Hom /Strobe (2 Wire) P2R 15 0.069 34 174 20.17 20.04 19.83 19.49 fall Horn /Strobe (2 Wire) P2R 115 0.069 38 212 20.16 20.03 19.80 19.45 Total current/amps 0.505 vdc loss 0.24 0.37 0.60 0.95 Model 5700 Fire Alarm Control ol Pan 9Ir O! __ - .� Ilea Ir w ii. =VW! SDI CI ra SOI •IC I I I y i �.'L' ■ , -. CI 11 e . . . ..--, , , •:: 1 11111. **WM - .210 1 ,_. lill � 5.00? SOW) Lw U1 1!71•• r7N.IfN • R L 5700 5496 Specifications S -BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: 120 VAC, 60 Hz, 1.5A Features the same 80 character backlit LCD User - friendly Windows software for remote Total Accessory Load: 2.5A @ 27.4 VDC display keypad and firefighter's key switch as programming of 5700s using a PC. Upload Notification Power: 2.5A @ 27.4 VDC, power- the 5700. The system can be fully and view panel account information, event limited programmed and operated from any 5860. history, and detector status. Standby Current: 200 mA 5860 is gray and 5860R is red. Alarm Current: 325 mA 5670 Silent Knight Software Suite 5496 Intelligent Power Module End -user facility management software allows 2.5 @ Notification/Aux 7.4 Power Circuits: A 6 amp notification power expander that y mans g 2.5A @ 27.4 VDC per circuit, t viewing of detector status and event history power- limited provides four additional power - limited via modem or direct connection. Battery Charging Capacity: 7.0 -35.0 AH notification appliance circuit outputs. Battery Size: 7 AH max. allowed in FACP 5880 LED/I0 Module RBB cabinet. Larger capacity batteries can be Features 40 LED outputs, 8 normally open dry Remote Battery Box Accessory Cabinet. Use housed in an RBB accessory cabinet. p y p en ry if backu p batteries are too large to fit into contact inputs and one piezo output. Physical FACP cabinet. Dimensions: Dimensions: 5865 - and 5865 - 16" W x 10" H x 6" D 12.75 "Wx15.2 "Hx3.4 "D Remote LED Annunciator (406 mm W x 254 mm H x 152 mm D) (32.39 W x 38.42 H x 8.57 D cm) Features 30 Programmable LED (15 red and SD505 - DTS - 15 yellow) outputs and a piezo sounder. The Weight: 11.5 IbS. (5.2 kg) 5865 -4 adds a silence and reset switch to the Remote test switch that provides remote key Color: Red package. operated test function and annunciation of detector alarm with SD505- DUCTR. Telephone Requirements: 5883 Relay Board FCC Part 15 and Part 68 approved Features 10 general purpose Form C relays. Hochiki and SK Devices Type of Jack: RJ31X (two required) Used with 5880 module. See the specification sheets listed below for a rovals 5824 Serial /Parallel Printer complete listing of the Hochiki and SK A NFP 13, NFPA 15, NFPA 16, NFPA 70, & Interface Module devices. Provides one parallel and one RS -232 serial 53624 Hochiki Devices Specification Sheet NFPA 72: Central Station; Remote Signalling; port for connecting a printer to 5808. Use to Local Protective Signalling Systems; Auxiliary print a real-time log of system events, detector 53623 SK Protocol Devices Specification Protected Premises Unit; & Water Deluge Sheet status reports, and event history. Interfaces Releasing Service. Suitable for automatic, with building control system. manual, waterflow, sprinkler supervisory (DACT non - coded) signalling services. Other Approvals: UL Listed; CSFM 7170 -0559: 144; MEA 429 -92 -E Vol. XVI. 13 SI LLN I This document is not intended to be used for installation purposes. We try to keep our product MADE IN AMERICA information up- to-date and accurate. We cannot cover all specific applications or anticipate all - KNIGHT requirements. All specifications are subject to change without notice. For more information, P/N 350392 Rev. F contact Silent Knight 12 Clintonville Road, Northford, CT 06472 -1610 ECN 09-520 09/09 try Hamm* Phone: (800) 328-0103 or (203) 484 -7161, Fax: (203) 484 -7118. www.silentknight.com IntelliKnight & JumpStart are Registered Trademarks of Silent Knight © 2009 Honeywell International Inc. r Flexput is a Trademark of Silent Knight IntelliKnight® Model 5700 Single Loop Addressable /+ Fire Alarm Control System r . The affordable addressable fire alarm a 7 control panel solution. IntelliKnight Model 5700 is a 50 point class leading single loop Jf addressable fire alarm control /communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 800 - 328 -0103 or in Connecticut, call 203 - 484 -7161. Description The basic IntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial /parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 supports Hochiki or SK devices. 5700 also features a powerful built -in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built -in support for up to 50 Hochiki devices or 50 SK detectors and 50 SK modules. • Up to 125 zones and 125 output groups • Uses standard wire —no shielded or twisted pair required • Built -in digital communicator.= ' - =�.• • Central station reporting by point or by zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC Model 5700 • Distributed, intelligent power • Drift compensation Installation • 13 pre - programmed output cadences (including ANSI -3.41) The 5700 is a surface mount FACP. and 4 programmable outputs • Notification circuits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, Compatibility constant, or door holder power The 5700 SLC supports multiple device types of the • Built -in synchronization for AMSECO, Gentex®, Faraday, same protocol: System Sensor® and Wheelock® appliances • Hochiki • Built -in annunciator with 80- character LCD display • SK • RS -485 bus provides communication to system accessories • Upload or download programming, event history, or detector You cannot mix Hochiki and SK devices on a FACP. status onsite or from a remote location using a PC and However, any combination of addressable devices of the 5660 Silent Knight Software Suite (SKSS) same protocol can be used on the 5700. • Improvements in SKSS deliver five times faster upload /downloads • Built -in RS -232 interface for programming via PC • Built -in Form C trouble relay rated at 2.5A at 27.4 VDC • Two built -in Form C programmable relays rated at 2.5A at SILENT 27.4 VDC • Programmable date setting for Daylight Saving Time ` KNIGHT by Honeywell SK -Photo . ,, and SK- Photo -T (1 1 , i r - %k ,,..a f J • . .. Intelligent Photoelectric Smoke Sensors ii. x • M` ' r ICS ;, The SK -Photo is a photoelectric smoke detector and the SK- Photo -T is a ,. • photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800 - 328 -0103 or in Connecticut, call (203) 484 -7161. Description • Plug -in mounting provides ease of SK -Photo and SK- Photo -T are plug-in lu in installation ' type smoke sensors that combine a • Tamper -proof feature available on photoelectric sensing chamber with mounting bases addressable analog communications. • Listed for use in duct applications Point ID capability allows each • detector's address to be set with rotary Rotary address switches for fast installation address switches, providing exact I detector locations for selective • UL Listed maintenance when chamber contamination reaches unacceptable FM Approved levels. Specifications SK -Photo and SK- Photo -T have a physical unique optical sensing chamber that is Height: 2.0" (5.0 cm) engineered to sense smoke produced by a wide range of combustion Diameter: 4.1" (10.4 cm) sources. In the SK- Photo -T, dual Shipping Weight: 5.2 oz. (147 g) SK - Photo (Base included) electronic thermistors add 135 °F (57 °C) Electrical thermal technology to maximize Operating Voltage: 15-32 VDC Compatibility detection. Standby Current: The SK -Photo and SK- Photo -T are A 24 VDC Maximum compatible with the following Features 300 P @ IntelliKnight FACPs: • Sleek, low - profile design Alarm Current: 6.5 mA @ 24 VDC max 5700 • Base included (with LED on) 5808 • Reliable analog communications for Environmental 5820XL trouble free operation Operating Temperature SK -Photo and SK- Photo -T are SK- Photo: 32° — 120 °F (0 °C — 49 °C) compatible with the following detector • Age resistant polymer housing SK- Photo -T: 32 ° — 100°F (0°C — 38°C) bases: • Dual electronic thermistor design on Humidity: 10% — 93% non condensing B210LP (included) 6" base the SK- Photo -T B501 2 wire base • Superior EMI resistance for reliability Other Ratings B501BHT -2 Temporal base SK- Photo -T Thermal: Fixed B224RB Relay base • Simple field cleaning for code temperature set point 135 °F (57 °C) B224B1 Isolator base compliance Velocity: 0 — 4000 fpm (0 — 20 m /sec) B501BH -2 Sounder base • Variety of mounting options to meet SK -Photo Insect Screen Hole Size: any application 0.016" (0.41 mm) nominal • Dual LED indicators for 360° visibility SILENT • Detector transmits signal to indicate KNIGHT maintenance is required • Optional remote LED annunciator by Honeywell (System Sensor® PN RA100Z) Model SK -Photo and SK- Photo -T Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK -Photo or SK- Photo -T with thermal. The combination detector head, and twist -lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK -Photo or SK- Photo -T. Base shall be the appropriate twist -lock base part number B210LP (included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK -Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. sic IN OUT • - - RAMIE (Optimal, i PM ; 4111111111N1 Ili I la r‘ii r' I m " lc" II MI } • III II + .......- ......... ................... "'"i'�l. ,............. r ,..... � > . ... mo•wdnq Mom SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject FORM# 350118 Rev A, to change without notice. For more information, contact Silent Knight 12 © 2009 Honeywell International Inc. C y Honeywea Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, Fax: (203) 484 -7118. www.silentknight.com SK- Pull-SA and SK- Pull-DA P Intelligent Pull Stations ,, The SK- Pull -SA and SK- Pull -DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight 1 fire control panel. Extremely easy to operate, the SK- Pull -DA/SA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1- 800 - 328 -0103 or in Connecticut, call (203) 484 -7161. Description The SK- Pull -SA is a single action pull station requiring only FIRE one motion to activate the station. The SK- Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight vuLL nowh Intelliknight series fire alarm control panels ( FACPs). Features • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition SK-Pull-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks E • Meets the Americans with Disabilities Act Accessibility Push Guidelines (ADAAG) controls and operating mechanisms PuLLO guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 lbs maximum pull force to active sawn • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble -free operation SK-Pull-DA • Braille text on station handle Compatibility • Handle latches in down position and the word Activated The SK -Beam and SK- Beam -T are compatible appears, clearly indicating the station has been pulled with the following IntelliKnight FACP's: • Rotary address switches for fast installation 5700 5808 • UL Listed, including UL 38, Standard of Manually Actuated 5820XL Signaling System SILENT V s KNIGHT by Honeywell Model SK- Pull-Da and SK- Pull-SA Engineering Specifications , k. The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK- Pull -SA single action pull station or SK- Pull -DA, dual action pull station. SK- Pull -DA or SK- Pull -SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. I i llir Class 1 :IISSB • c..r.rw 1 L, iif r B t t I 1 tea 8 t t I I `�::; II _ t ill_ - t Winn SK Pull SA 4 SK Put OA Pug Stations Specifications Electrical Physical Operating Voltage: 15 -32 VDC Height: 5.5" (14 cm) Average Operating Current (LED flashing): 300 pA Width: 4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32° — 120 °F (0 °C — 49 °C) Bi- Colored LED: Humidity: 10% — 93% non - condensing Blinking Green: Normal Steady Red: Alarm Accessories Switch: Single pole, single throw (SPST) normally open (N /O) BG -TR Optional trim ring. switch which closes upon activation of the pull station SB -I /O Surface backbox This document is not intended to be used for installation purposes. We try to MADE IN AMERICA SILENT keep our product information up -to -date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject . t to change without notice. For more information, contact Silent Knight FORM# 350135 Rev A 12 Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, © 2009 Honeywell International Inc. by Honeywell Fax: (203) 484 -7118. www.silentknight.com SK -Relay , 1101 1 ° �4 Intelligent Relay Module The SK -Relay Module is intended for use in intelligent, two -wire systems ' where the individual address of each module is selected using the built in ` !`' 110 rotary switches. r For more information about the Intelliknight system, or to locate you nearest source, please call 800 - 328 -0103 or in Connecticut, call (203) 484 -7161. Description The SK -Relay is an addressable relay module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK -Relay allows a Silent Knight FACP to switch discrete y S contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK -Relay contacts can be used for virtually any normally open or normally closed application. Each SK -Relay is _ 1, programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the SK- Relay, the SK -Relay relay is triggered by the FACP. Installation The SK -Relay mounts directly into a 4" square Features electrical box. The box must have a minimum • Two sets of Form C contacts depth of 2 -1/8 ". A surface mount electrical box • Rotary address switches for fast installation (System Sensoro PN SMB500) is available • Contacts are rated for a variety of amps (see Specifications) from Silent Knight • Panel controlled status LED that flashes green in normal state and is solid red in alarm Compatibility The SK -Relay is compatible with the following • Relay programming is completely flexible —can be mapped to IntelliKnight FACP's: zone conditions 5700 5808 • Polling LED visible through the cover plate 5820XL • Attractive ivory cover plate • SEMS screws for easy wiring SILENT • UL Listed ti KNIGHT by Honeywell Model SK -Relay 1 To Next Device - • If Any Wiring to Terminals 3 - 9 is Not Power 4. 4 Limited. the CB500 Barrier is Required. The CB500 Includes a Non -Power Limited Label, n n Which Must Be Placed Over the Power Limited 0 O O , Terminal Information on the Name Plate Label. 0 / Relay Common 2 • • `• • Ell Normally Closed 2 XI • ' Normally Open 2 IN 7 ..,'• = sie _ From Compatible FACP Relay Common 1 BM • t • 3 Bli + or Previous Device Normally Closed 1 ®• s PH r•, v 1 — Normally Open 1 Module Does Not Supervise O O O f) Controlled Circuits V U U Wiring the SK-Relay Module Specifications End -of -Line Resistance: not used Physical Standby Current: 300 pA max @ 24 VDC (one Height: 4.65" communication every 5 sec with LED enabled) Width: 4.25" LED Current: 5.5 mA (with LED latched on) Depth: 1.1" SLC Loop Resistance: 4052 max. Shipping Weight: 6.3 oz (196 g) Relay Contact Ratings 3.0A @ 30 VDC resistive Electrical Operating Voltage: 15 - 32 VDC 0.9A @ 110 VDC resistive Current Draw: 6.5 mA max (LED on) 0.9A @ 125 VAC resistive Operating Current 0.5A @ 125 VAC inductive (PF = .35) 230 pA (LED flashing) direct poll 0.7A @ 75 VAC inductive (PF = .35) 255 pA (LED flashing) group poll SILENT N This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are MADE IN AMERICA subject to change without notice. For more information, contact Silent Knight FORM# 350127 Rev A by Honeywell 12 Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, © 2009 Honeywell International Inc. Fax: (203) 484 -7118. www.silentknight.com SK- Monitor A ,Q H Intelligent Monitor Module ,, The SK- Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1- 800 - 328 -0103 or in Connecticut, call (203) 484 -7161. Description The SK- Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK- Monitor is intended for use in . z intelligent, two -wire systems, where individual address of each module is selected using the built -in rotary switches. ., The SK- Monitor supports Class A supervised or Class B • • ..± "�.;, ,, ,� supervised wiring to the load device. Conventional 4 -wire smoke detectors can be monitored for alarm and trouble ` conditions. Features • Single contact monitor • Support for Class A and Class B wiring • Fully supervised SK- Monitor • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate Compatibility The SK- Monitor is compatible with the following • Rotary address switches for fast installation IntelliKnight FACP's: • SEMS screws for easy wiring 5700 • UL Listed 5808 5820XL Installation The SK- Monitor mounts directly into a 4" square electrical box. The box must have a minimum depth of 2 -1/8 ". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. SILENT 1 0 KNIGHT by Honeywell Model SK- Monitor To Next Device ■ 0 0O Class B � • " . • MI {.ms • •, 1 131E - From Compatibie Silent Knight • FACP or Previous Device inituhnq Device Circuit NFPA Style B n O 0 Power Limited 230 we Max ft 12 VDC Max v ■ ■ Class A canny • To Next Device Class B 1Mnng Any Number of UL Lasted Contact Closure • • Devices May Be Used Do Not Mix Fire Alarm O o O ^ initiating Devices. Supervisory. or Security Devices v on the Same Module Class A _....._ _ '. • ■I ......._ ...... ......:........._.............. nr • ; p fn; ar.. r ..• • '� ». • - From Compatible Silent Knight ~ 1 ±1 ' ' l • FACP or Previous Device EOL Rs M$oe Is Internal (� fl at Terminals e & 9 (f • ■ Wiring SK- Monitor Modules Specifications 5.5 mA (with LED latched on) Physical LED Current: 5.5 mA (with LED latched on)End -of -Line Height: 4.5" (11.4 cm) Resistance: 47K Width: 4" (10.2 cm) Initiating Device Circuit Wiring Resistance: 1,500 max Depth: 1.25" (3 cm) SLC Loop Resistance: 40 max. Shipping Weight: 6.3 oz (196 g) Environmental Electrical Operating Temperature: 32 °F — 120 °F (0 °C — 49 °C) Operating Voltage: 15 — 32 VDC Humidity: 10% — 93% non - condensing Current Draw (LED on): 5.0 mA max Operating Current (LED flashing): 375 pA Ordering Information SK- Monitor Monitoring Module Standby Current: 400 pA max @ 24 VDC (one communication every 5 sec with Accessories 47K EOL) SMB500 4" Square Surface Mount Electrical Box 550 pA max @ 24 VDC (one communication every 5 sec with EOL <1K) This document is not intended to be used for installation purposes. We try to MADE IN AMERICA tit SILENT keep our product information up -to -date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight FORM# 350131 Rev A 12 Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, © 2009 Honeywell International Inc. by Honeywell Fax: (203)484 -7118. www.silentknight.com a M 00 worr, BATTERIES Werker SLA technology offers high- density power that out - performs traditional lead acid batteries. The Absorbed Glass Mat (AGM) construction is designed for efficient gas recombination and allows for maintenance -free operation. Werker SLA batteries maintain their high capacity with a design that is resistant to damage caused by deep discharge. Every Werker SLA battery is inspected to ensure the highest standards in materials and fabrication. Battery Features: Charger Features: • Werker SLA AGM batteries contain a proprietary grid alloy New! SLA Chargers formula. This formula combined with the advanced plate curing techniques offer improved performance. • Regulated trickle charge for "float" mode charging • Werker batteries contain a unique electrolyte formula with a • Short circuit protected special sub - colloid additive for higher reliability and longer life. • Reverse polarity protected • More than 1,000 discharge /recharge cycles. • Thermal protection in case of overload • The unique construction and sealing techniques of the Werker • Alligator clips battery guarantee leak -proof operation. • Color LED to indicate state of charger • Heavy -duty lead calcium tin alloy grids provide an extra margin of performance and service life in cyclic applications, even after repeated over - discharges. • Quality Assurance Engineers monitor and control the entire • production process. We r k e r .. =soy X SLA/AGM BATTERIES Flame Capacity Dimensions Height Over Weight Flame Capacity Dimensions Height Over Weight hem I Volts Retardant Alt Lx W x H (in.) Terminal (in.) (Ibs.) Item a Volts Retardant Ah L x W x H (in.) Terminal (in.) Ilbs.) WKAl2 -0.8WI 12 0.8 3.76 x 0.98 x 140 24 0.8 WKAl2 -7.5F7 12 75 5.94 x 2.56 x 3.74 3.98 6.0 WKAl2 -1.3F 12 13 3.82 x 1.69 x 2.05 2.28 1.4 WKAl2 -12F2 12 12 5.94 x 3.90 x 3.74 3.98 9.3 W1(A1 - 12 2 5.91 x0.79 x3.54 3.54 1.7 WKAl2 -18NBI 12 18 7.13 x 3.03 x 6.57 6.57 13.9 WKAl2 -2.3F 12 - 2.3 6.97 x 1.38 x2.40 2.64 2.0 WKAl2 -26N9 12 26 650 x 6.93 x 4.92 4.92 703 WKAl2-3.3F 12 - 12 5.28 x 2.64x 2.40 2.64 3.2 WKAl2-33C 12 35 7.72 x 5.16 x 6.10 6.57 25.4 WKAl2-5.1A 12 - 4,5 5.51 x 1.89 x 3.98 4.21 4.4 WKA17 -33J 12 35 7.72 x 5.16 s 6.10 7.09 25.4 WKAl2 -5F 12 - 5 3.54 x 2.76 x 3.98 4.21 4.0 WKAl2.44C/FR 12 Y 45 7.80 x 6.54 x 6.85 6.85 35.7 WKA17 -7.5F 12 - 7 5 594 x 2.56 x 3.74 3.98 6.0 WKA17 -55 C/FIt 12 Y 60 902 x 5.43 x 819 835 40.3 Continued on Next Page For more information please contact: Rep lacementUP�2 b �yoSAede www.Re pla c e m e ntUPSb attery. c o m Phone: 952 - 217 -6611 Email: info@replacementupsbattery.com